Satellite avoidance Basdard configuration example

ADAPTER:Endpoint= [NAME= ArgosSatelliteAvoidance,HOST=0.0.0.0,PORT=60141]

STATE:BasdaServiceStateMachine= ONLINE

SVC:String= "Drag and drop this node for a GUI " +UI=$INSROOT/share/argos/ui/argos_satellite_avoidance.ui"

SVC.LOAD= [NAME= ArgosSatellite, LIB= ArgosBasdaServiceSatelliteAvoidance]

SVC.DEVICE_ADDRESS:String="tcp://149.217.43.12:6001"

SVC.CMD.SETPAMFILENAME.PAM_FILENAME:String="sample.pam"

SVC.CMD.ACTIVATECALCULATIONS

SVC.CMD.DEACTIVATECALCULATIONS

SVC.CURRENT_PAM_FILENAME:String

SVC.REMAINING_TIME:Time

SVC.SAT_STATE:String

SVC.SAT_VERSION:String

SVC.IS_SAT_ACTIVE:Bool

SVC.IS_SAT_CONNECTED_TO_MCSPU:Bool

SVC.IS_SAT_IN_SIMULATION:Bool

SVC.IS_REACHABLE:Bool

Note: Properties in bold font must exist in the configuration file of this basdard service.