Prosilica Property Tree

The Prosilica camera system is represented by the following properties:

AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.ALGORITHM:String=Mean AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.MAXIMUM_MILLISECOND:U32=500000 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.MINIMUM_MILLISECOND:U32=8 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.OUTLIERS_PERCENT:U32=0 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.RATE_PERCENT:U32=100 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.TARGET_PERCENT:U32=50 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_EXPOSURE.TOLERANCE_PERCENT:U32=5 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.MAXIMUM_DB:U32=25 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.MINIMUM_DB:U32=0 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.OUTLIERS_PERCENT:U32=0 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.RATE_PERCENT:U32=100 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.TARGET_PERCENT:U32=50 AVTCAM.ICS.CAMERA.DEV.CFG.AUTO_GAIN.TOLERANCE_PERCENT:U32=5 AVTCAM.ICS.CAMERA.DEV.CFG.CCD.CHANNELS:Size=[1,1] AVTCAM.ICS.CAMERA.DEV.CFG.CCD.MTX.FRAMEOFF:SeqPoint=0,0 AVTCAM.ICS.CAMERA.DEV.CFG.CCD.MTX.SCALE:SeqSize=1,1 AVTCAM.ICS.CAMERA.DEV.CFG.EXPOTIME:Double=1 AVTCAM.ICS.CAMERA.DEV.CFG.PACKET_SIZE:U32=8228 AVTCAM.ICS.CAMERA.DEV.CON:String=192.168.100.100

AVTCAM.ICS.CAMERA.SVC.CTRL.CFG.EXPO.NUMIMAGES:Int=1000 AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.READENDLESS AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.READMULTI AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.READMULTI.NUMIMAGES:Int=0 AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.READSINGLE AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETBINNING AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETBINNING.BIN:U16=2 AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETEXPOSURETIME AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETEXPOSURETIME.EXPOTIME:Time=00:00:00.000000 AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETFRAMERATE AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETFRAMERATE.FRAMERATE:Double=0 AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETGAINMODE AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETGAINMODE.GAIN:Int=0 +SELECT:SeqString=[Auto,AutoOnce,0,1,2,3,4,5] AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETPROGRAM AVTCAM.ICS.CAMERA.SVC.CTRL.CMD.SETPROGRAM.PROGRAM:Int=0 +SELECT:SeqString=[Auto,Manual,AutoOnce] AVTCAM.ICS.CAMERA.SVC.CTRL.VAR.CAM.IS_REACHABLE:Bool=1 AVTCAM.ICS.CAMERA.SVC.PUSH.CFG.UPFREQ:Time=00:00:01.000000 AVTCAM.ICS.CAMERA.SVC.PUSH.DEVICE:String=CameraAvt_1 AVTCAM.ICS.CAMERA.SVC.PUSH.VAR.IMAGE:BasdaImage=1:1:0 [680,512]:2 AVTCAM.ICS.CAMERA.SVC.PUSH.VAR.UPFREQ:Time=00:00:01.000000
Topic revision: r1 - 01 Jun 2018, AndrewColson
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback