Technical Data of Agilent 6k Family

Channels Ch 1, 2, 3 and 4 simultaneous acquisition
Bandwidth (\x963 dB)* DSO6014L: DC to 100 MHz DSO6054L: DC to 500 MHz DSO6104L: DC to 1 GHz
Maximum input CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk 5 Vrms with 50 Ω input
Full Scale range DSO6014L: 1 mV/div to 5 V/div (1 MΩ) DSO6054L: 2 mV/div to 5 V/div (1 MΩ or 50 Ω) DSO6104L: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω) Input impedance DSO6014L2: 1 MΩ \xB1 1%
Connector BNC
BW limit DSO6014L: 20MHz DSO6054L/6104L: 25 MHz selectable
Noise peak-to-peak DSO6014L: 3% full scale or 2 mV, whichever is greater DSO6054L: 3% full scale or 3.6 mV, whichever is greater DSO6104L: 3% full scale or 4.5 mV, whichever is greater

Initial Configuration

When connecting the oscilloscope to the network for the first time, or after rebooting the network NIC, it will try to get an IP address from the local DHCP server. If this step fails, it moves on to AutoIP mode. AutoIP uses a subnet mask of 255.255.0.0. The oscilloscope's IP address will be in the range 169.254.x.x where the x's are negotiated with the PC on the AutoIP network. Generally, the oscilloscope will end up at 169.254.254.254; however, this could be different depending on negotiation during AutoIP.

Once the IP address is identified, the oscilloscope can be accessed via web browser to the port 80, or via telnet, to the port 5024.

If you do not know the oscilloscope\x92s hostname you can reset the hostname as follows: 1. Press and release the Reset button on the front panel of the 6000L Series oscilloscope. This will reset the hostname to that which is printed on the label near the oscilloscope\x92s power cord connection. The following LAN parameters will be reset:
  • Hostname
  • IP address
  • Domain name
  • VISA address
  • Password