Side | Date![]() |
PP | WP | Ambient T | Remarks |
---|---|---|---|---|---|
DX | 18884 | 5872 | after first calibration unit alignment | ||
DX | 2014-11-30 | 18884 | 5862 | overwrote the park position -> not parked | |
DX | 2015-12-11 | 18870 | 5854 | 3.8C | Park position switch was replaced with mechanical one in between |
SX | 2015-12-11 | 18662 | |||
SX | 2016-02-24 | 18662 | 2.21C | ||
DX | 2016-02-24 | 5854 | 2.21C | ||
SX | 2016-05-15 | 18661 | 8.00C | ||
DX | 2016-05-15 | 5854 | 8.00C | ||
SX | 2017-04-28 | 18663 | 1.8C | The working pos switches have been changed to mechanical | |
DX | 2017-04-28 | 5854 | 1.8C | The working pos switches have been changed to mechanical | |
DX | 2017-12-02 | 5854 | 3.5C | ||
SX | 2017-12-02 | 18664 | 3.5C | ||
DX | 2015-02-xx | -- | 5872 |
Side | Date | X | Y | Z | RX | RY | Comment |
---|---|---|---|---|---|---|---|
DX | 2015-02-21 | -2.52 | -3.77 | 4.35 | -471 | 56 | |
DX | 2015-04-28 | -2.77 | -8.90 | -2.00 | 51.0 | 103.0 | after crash |
DX | 2015-04-29 | -2.59 | -8.84 | -1.96 | 46.9 | 109.6 | day |
DX | 2015-04-30 | -2.94 | -8.18 | -2.08 | -150 | 12 | day |
DX | 2015-05-01 | -2.94 | -8.18 | 2.08 | -44 | 62 | day |
DX | 2015-05-01 | -1.00 | -6.50 | -2.10 | -310 | 215 | night |
Side | Date | X | Y | Z | RX | RY | Comment |
SX | 2015-12-10 | 4.87 | -0.03 | 7.80 | 215 | -57 | Focus to be adjusted later in the run (Done 20151213) |
I | Attachment | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|
![]() |
VerificationMatrix.pdf | manage | 352 K | 07 Jun 2018 - 18:01 | AndrewColson | |
![]() |
argos_dx_calunit_loose_fiber.jpg | manage | 191 K | 06 Aug 2018 - 18:38 | AndrewColson |