= Overview of the devices =
- Delay generator                                [basda] 
- Cameras                                        [basda]

 * DVC
 * PN sensor

- Motors                                        [basda]

 * Piezos
 * Linear Stages
 * Circular

- Oscilloscopes                                  [basda] 
- Lasers                                         [basda] 
- Laser powermeters                              [basda] 
- BCUs                                           [basda] 
- Temperature monitors                           [basda] 
- I/O Switches                                   [basda] 
- Interlocks                                     [argos] 
- Shutters (P. Air)                              [argos] 
- Water Flowmeters                               [basda] 
- Light sources (on/off/brightness)              [argos] 
- Photons counters                               [argos]

 * TipTilt Controller

- Deformable micro mirrors                      [argos] 
- UEI Racktangle                                [argos] 
- TCS / DD                                         
- Mic / Cameras Suerv.                          [argos] 
- Aircraft detection device (on/off)            [argos]

Description and comments  ========================= 
- Delay generator:

 * Set delay between the triger signal and output
 * Set Master clock frequency
 * Tune with osciloscope
 * commands: +setPulse +setDelay +getFrequency +start +stop +getDivider

- Cameras:

 * Binning, framework, image display, integration time, read out freq, substract flat fill.
 * Single shots, sequences (with limitations) - fits/cube storage.
 * is it on/off
 * 

- Oscilloscopes:

 * Display the pulses
 * Wide range, voltage, volts/division, trigger levels
 * Calculate time distance between 2 points.
 * is it on/off

- Lasers:

 * GUI shall (service):
 * set/get pulse frequency [kHz]
 * diode operating current [%]
 * set/get diode standby on/of
 * set/get diode standby current [%]
 * get diode 1,2 temp [c]
 * get laser crystal temp [c]
 * water flow [l/min]
 * Operating hours for diode 1,2
 * device shall:
   * get External control settings
   * FPK start value
   * FPK Ramp
   * FPK reset time [usec]
   * FPK trigger source
   * SW version power supply
   * SW version Head
   * SW version FPGA

- Lasers Powermeters:

 * on/off
 * GUI parameter to see the returned value.

- Temperature monitors:

 * Display values
 * thresholds
 * alarms
 * 

- I/O switchess:

 * on/off

- Interlocks:

 * Lasers
   * External
   * zenith distanc
   * cover up
   * aircraft
 * swingarms/LBC
 * lucifer CAL

- Shutters:

 * open/ close
 * display

- Water Flowmeters

 * display values / thresholds - alarms

- Light sources

 * on/off/brightness

- Photons counters

 * TipTilt Controller

- Deformable micro mirrors

- UEI Racktangle

- TCS / DD

- Mic / Cameras Suerv.

- Aircraft detection device (on/off)