********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Sep 16 2009 to Sep 17 2009
 
    Reporting period beginning:   Wed Sep 16 17:53:05.198 2009
    Reporting period ending:      Thu Sep 17 06:34:55.529 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.08   100.0 %         66         66                      
                                                                       0.00    0.05    0.05    0.08
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.03    0.24    0.21    0.37   100.0 %         78         78                      
                                                                       0.03    0.24    0.21    0.37
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.22    0.21    0.37   100.0 %        577        577                      
                                                                       0.03    0.22    0.21    0.37
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.78    7.34    0.61   25.81    98.7 %         78         77          1           
                                                                       5.76    7.43    1.68   25.81
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    2.59    9.28    6.27   13.29   100.0 %         10         10                      
                                                                       2.59    9.28    6.27   13.29
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    2.59    9.06    6.06   13.08   100.0 %         10         10                      
                                                                       2.59    9.06    6.06   13.08
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   50.96   32.91    7.96  180.74   100.0 %         18         18                      
                                                                      50.96   32.91    7.96  180.74
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   25.88   13.01    1.05   87.20   100.0 %         18         18                      
                                                                      25.88   13.01    1.05   87.20
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   21.35    7.96    1.05   93.17   100.0 %         18         18                      
                                                                      21.35    7.96    1.05   93.17
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    2.43    4.64    0.55   23.43    99.2 %        485        481          4           
                                                                       2.26    4.59    0.55   22.92

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  SHUTDOWN  IIF        shutdown                                                      Wed Sep 16 18:26:04.342 2009  to  Wed Sep 16 18:26:04.342 2009   (  0.00) secs
                     IIF subsystem shut down

   2  STARTUP   IIF        startup                                                       Wed Sep 16 18:31:31.504 2009  to  Wed Sep 16 18:31:31.504 2009   (  0.00) secs
                     IIF subsystem started, version 6.12

   3  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:53:29.577 2009  to  Thu Sep 17 02:53:33.611 2009   (  4.03) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

   4  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:53:35.692 2009  to  Thu Sep 17 02:53:39.722 2009   (  4.03) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

   5  FAILED    IIF        command.moveFocus                                             Thu Sep 17 02:53:44.956 2009  to  Thu Sep 17 02:53:45.568 2009   (  0.61) secs
                     IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:55:27.096 2009  to  Thu Sep 17 02:55:50.525 2009   ( 23.43) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   7  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 05:12:00.897 2009  to  Thu Sep 17 05:12:12.821 2009   ( 11.92) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3777                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7554                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    14                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      94                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       5                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            40
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      28                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       8                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      51                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       6                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 16           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       6                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      45                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     105                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      39                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Sep 16 17:59:44.952 2009  to  Wed Sep 16 17:59:44.952 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Sep 16 17:59:44.957 2009  to  Wed Sep 16 17:59:44.957 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Sep 16 17:59:45.058 2009  to  Wed Sep 16 17:59:45.058 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.073 2009  to  Wed Sep 16 17:59:46.073 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.074 2009  to  Wed Sep 16 17:59:46.074 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.074 2009  to  Wed Sep 16 17:59:46.074 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.075 2009  to  Wed Sep 16 17:59:46.075 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.076 2009  to  Wed Sep 16 17:59:46.076 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.076 2009  to  Wed Sep 16 17:59:46.076 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.077 2009  to  Wed Sep 16 17:59:46.077 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.077 2009  to  Wed Sep 16 17:59:46.077 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.636 2009  to  Wed Sep 16 21:40:54.636 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.636 2009  to  Wed Sep 16 21:40:54.636 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.637 2009  to  Wed Sep 16 21:40:54.637 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.637 2009  to  Wed Sep 16 21:40:54.637 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.638 2009  to  Wed Sep 16 21:40:54.638 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.638 2009  to  Wed Sep 16 21:40:54.638 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.639 2009  to  Wed Sep 16 21:40:54.639 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.639 2009  to  Wed Sep 16 21:40:54.639 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 00:40:40.264 2009  to  Thu Sep 17 00:40:40.264 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:52:47.917 2009  to  Thu Sep 17 01:52:47.917 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:53:10.601 2009  to  Thu Sep 17 01:53:10.601 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:55:27.252 2009  to  Thu Sep 17 01:55:27.252 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].terc.getfocalstationcount.command. . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     side[1].terc.getfocalstationcount.command. . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.06

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                  1          3
     side[1].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                  1          3
     tel.notify_disconnected. . . . . . . . . . . . . . . . . . . .      15                      
     tel.notify_connected . . . . . . . . . . . . . . . . . . . . .      10                      

OSS Events of Interest

   1  FAILED    OSS        side[0].swa                                                   Wed Sep 16 17:59:46.520 2009  to  Wed Sep 16 17:59:46.520 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

   2  FAILED    OSS        side[1].swa                                                   Wed Sep 16 17:59:49.412 2009  to  Wed Sep 16 17:59:49.412 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

   3  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 18:18:35.652 2009  to  Wed Sep 16 18:18:35.652 2009   (  0.00) secs
                     The oss was shut down.

   4  STARTUP   OSS        startup                                                       Wed Sep 16 20:22:47.420 2009  to  Wed Sep 16 20:22:47.420 2009   (  0.00) secs
                     The oss was started.

   5  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 20:40:11.171 2009  to  Wed Sep 16 20:40:11.171 2009   (  0.00) secs
                     The oss was shut down.

   6  STARTUP   OSS        startup                                                       Wed Sep 16 20:43:26.655 2009  to  Wed Sep 16 20:43:26.655 2009   (  0.00) secs
                     The oss was started.

   7  STARTUP   OSS        side[1].terc.startup.command                                  Wed Sep 16 20:44:10.272 2009  to  Wed Sep 16 20:44:10.272 2009   (  0.00) secs
                     side[1].terc: [startup] command.started

   8  STARTUP   OSS        side[1].terc.startup.command                                  Wed Sep 16 20:44:11.222 2009  to  Wed Sep 16 20:44:11.222 2009   (  0.00) secs
                     side[1].terc: [startup] command.complete

   9  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 20:46:28.200 2009  to  Wed Sep 16 20:46:28.200 2009   (  0.00) secs
                     The oss was shut down.
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.10    0.10    0.16   100.0 %        577        577                      
                                                                       0.01    0.10    0.10    0.16
     telescope.command.getRotatorTrajectory . . . . . . . . . . . .    0.02    0.11    0.09    0.17   100.0 %         78         78                      
                                                                       0.02    0.11    0.09    0.17
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         10         10                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         18         18                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.22    0.55    0.31    0.82   100.0 %         18         18                      
                                                                       0.22    0.55    0.31    0.82

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                577           

PCS Events of Interest

   1  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:14.520 2009  to  Thu Sep 17 03:02:14.520 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   2  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:23.859 2009  to  Thu Sep 17 03:02:23.859 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   3  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:33.194 2009  to  Thu Sep 17 03:02:33.194 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   4  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:42.627 2009  to  Thu Sep 17 03:02:42.627 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   5  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:51.835 2009  to  Thu Sep 17 03:02:51.835 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   6  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:00.966 2009  to  Thu Sep 17 03:03:00.966 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   7  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:10.100 2009  to  Thu Sep 17 03:03:10.100 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   8  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:19.265 2009  to  Thu Sep 17 03:03:19.265 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

   9  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:28.608 2009  to  Thu Sep 17 03:03:28.608 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  10  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:37.943 2009  to  Thu Sep 17 03:03:37.943 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  11  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:47.191 2009  to  Thu Sep 17 03:03:47.191 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  12  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:56.314 2009  to  Thu Sep 17 03:03:56.314 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  13  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:05.660 2009  to  Thu Sep 17 03:04:05.660 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  14  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:14.770 2009  to  Thu Sep 17 03:04:14.770 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  15  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:24.039 2009  to  Thu Sep 17 03:04:24.039 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  16  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:33.155 2009  to  Thu Sep 17 03:04:33.155 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  17  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:42.462 2009  to  Thu Sep 17 03:04:42.462 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  18  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:51.578 2009  to  Thu Sep 17 03:04:51.578 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  19  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:00.885 2009  to  Thu Sep 17 03:05:00.885 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  20  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:10.247 2009  to  Thu Sep 17 03:05:10.247 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  21  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:19.569 2009  to  Thu Sep 17 03:05:19.569 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  22  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:28.895 2009  to  Thu Sep 17 03:05:28.895 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  23  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:38.178 2009  to  Thu Sep 17 03:05:38.178 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  24  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:48.193 2009  to  Thu Sep 17 03:05:48.193 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  25  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:57.546 2009  to  Thu Sep 17 03:05:57.546 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.62    2.62    2.05    4.06   100.0 %         64         64                      
                                                                       0.62    2.62    2.05    4.06
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          2          2                      
                                                                       0.00    1.05    1.05    1.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    2.96    4.13    0.00   25.30    98.8 %        584        577          7           
                                                                       2.90    4.13    1.25   25.30

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            58
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                            43
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                            77
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            42
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      64                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 27           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 27           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      27                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:03.532 2009  to  Thu Sep 17 02:52:09.796 2009   (  6.26) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:05.313 2009  to  Thu Sep 17 02:52:11.577 2009   (  6.26) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:59.248 2009  to  Thu Sep 17 02:53:39.350 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:59.256 2009  to  Thu Sep 17 02:53:33.239 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:33.239 2009  to  Thu Sep 17 02:53:33.289 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:39.350 2009  to  Thu Sep 17 02:53:39.401 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:44.562 2009  to  Thu Sep 17 02:53:44.562 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:45.199 2009  to  Thu Sep 17 02:53:45.249 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:54:29.636 2009  to  Thu Sep 17 02:54:29.636 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:55:32.923 2009  to  Thu Sep 17 02:55:50.203 2009   ( 17.28) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:04:16.188 2009  to  Thu Sep 17 03:04:16.188 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:04:16.138 2009  to  Thu Sep 17 03:04:16.138 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  13  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:07:44.156 2009  to  Thu Sep 17 03:07:44.156 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:07:44.106 2009  to  Thu Sep 17 03:07:44.106 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:09:28.078 2009  to  Thu Sep 17 03:09:28.078 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:09:28.128 2009  to  Thu Sep 17 03:09:28.128 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:15:03.939 2009  to  Thu Sep 17 03:15:03.939 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  18  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:15:03.990 2009  to  Thu Sep 17 03:15:03.990 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  19  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:25:08.396 2009  to  Thu Sep 17 03:25:08.396 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:25:08.346 2009  to  Thu Sep 17 03:25:08.346 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:31:48.271 2009  to  Thu Sep 17 03:31:48.271 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:31:48.321 2009  to  Thu Sep 17 03:31:48.321 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:40:11.259 2009  to  Thu Sep 17 03:40:11.259 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:40:11.208 2009  to  Thu Sep 17 03:40:11.208 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:44:07.421 2009  to  Thu Sep 17 03:44:07.421 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:44:07.371 2009  to  Thu Sep 17 03:44:07.371 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:44:44.301 2009  to  Thu Sep 17 03:44:44.301 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:44:44.250 2009  to  Thu Sep 17 03:44:44.250 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:50:02.168 2009  to  Thu Sep 17 03:50:02.168 2009   (  0.00) secs
                     left PMC PMC closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:50:02.117 2009  to  Thu Sep 17 03:50:02.117 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

  31  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:51:01.407 2009  to  Thu Sep 17 03:51:01.407 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:51:01.458 2009  to  Thu Sep 17 03:51:01.458 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:57:19.950 2009  to  Thu Sep 17 03:57:19.950 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:57:20.000 2009  to  Thu Sep 17 03:57:20.000 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:44:05.720 2009  to  Thu Sep 17 04:44:05.720 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:44:05.771 2009  to  Thu Sep 17 04:44:05.771 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:47:39.987 2009  to  Thu Sep 17 04:47:39.987 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:47:40.039 2009  to  Thu Sep 17 04:47:40.039 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:51:07.955 2009  to  Thu Sep 17 04:51:07.955 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:51:08.007 2009  to  Thu Sep 17 04:51:08.007 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:54:26.225 2009  to  Thu Sep 17 04:54:26.225 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:54:26.275 2009  to  Thu Sep 17 04:54:26.275 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:09:11.589 2009  to  Thu Sep 17 05:09:11.589 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  44  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:09:11.640 2009  to  Thu Sep 17 05:09:11.640 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  45  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 05:12:04.239 2009  to  Thu Sep 17 05:12:12.500 2009   (  8.26) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  46  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:15:37.430 2009  to  Thu Sep 17 05:15:37.430 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  47  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:15:37.480 2009  to  Thu Sep 17 05:15:37.480 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  48  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:16:16.224 2009  to  Thu Sep 17 05:16:16.224 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:16:16.275 2009  to  Thu Sep 17 05:16:16.275 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:15.273 2009  to  Thu Sep 17 05:27:15.273 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:15.223 2009  to  Thu Sep 17 05:27:15.223 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  52  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:15.623 2009  to  Thu Sep 17 05:27:15.623 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:15.693 2009  to  Thu Sep 17 05:27:15.693 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:44.819 2009  to  Thu Sep 17 05:27:44.819 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:44.869 2009  to  Thu Sep 17 05:27:44.869 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  56  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:36:14.091 2009  to  Thu Sep 17 05:36:14.091 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:36:14.041 2009  to  Thu Sep 17 05:36:14.041 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:37:20.182 2009  to  Thu Sep 17 05:37:20.182 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:37:20.130 2009  to  Thu Sep 17 05:37:20.130 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:54:59.443 2009  to  Thu Sep 17 05:54:59.443 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:54:59.493 2009  to  Thu Sep 17 05:54:59.493 2009   (  0.00) secs
                     right PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.43    4.42    0.34   23.07    99.2 %        485        481          4           
                                                                       2.26    4.37    0.34   22.70
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.10   100.0 %         36         36                      
                                                                       0.01    0.05    0.05    0.10
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.78    7.22    0.40   25.70    98.7 %         78         77          1           
                                                                       5.76    7.31    1.57   25.70
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.43    4.53    0.44   23.17    99.2 %        485        481          4           
                                                                       2.26    4.48    0.44   22.81
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.43    4.21    0.13   22.86    99.2 %        485        481          4           
                                                                       2.26    4.16    0.13   22.50
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    2.96    4.25    0.00   25.49    98.8 %        584        577          7           
                                                                       2.90    4.25    1.36   25.49
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    1.17    1.16    1.17   100.0 %          2          2                      
                                                                       0.00    1.17    1.16    1.17
     primaryMirror.command.clearPositions . . . . . . . . . . . . .    0.00    6.48    6.48    6.49     0.0 %          2                     2           
                                                                                                   
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.09    0.06    0.27   100.0 %        148        148                      
                                                                       0.04    0.09    0.06    0.27
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.78    7.11    0.27   25.60    98.7 %         78         77          1           
                                                                       5.76    7.20    1.47   25.60
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.09   100.0 %        485        485                      
                                                                       0.00    0.05    0.05    0.09

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                 54           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.clearPositions                          Thu Sep 17 02:52:03.422 2009  to  Thu Sep 17 02:52:09.907 2009   (  6.49) secs
                     left PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:03.474 2009  to  Thu Sep 17 02:52:09.854 2009   (  6.38) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:05.256 2009  to  Thu Sep 17 02:52:11.635 2009   (  6.38) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.clearPositions                          Thu Sep 17 02:52:05.205 2009  to  Thu Sep 17 02:52:11.687 2009   (  6.48) secs
                     right PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:59.195 2009  to  Thu Sep 17 02:53:39.295 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:59.198 2009  to  Thu Sep 17 02:53:33.183 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:53:29.684 2009  to  Thu Sep 17 02:53:33.452 2009   (  3.77) secs
                     right PSF ApplyZernikes failed

   8  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:53:29.632 2009  to  Thu Sep 17 02:53:33.504 2009   (  3.87) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

   9  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:53:29.857 2009  to  Thu Sep 17 02:53:33.400 2009   (  3.54) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:33.183 2009  to  Thu Sep 17 02:53:33.347 2009   (  0.16) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:53:35.804 2009  to  Thu Sep 17 02:53:39.563 2009   (  3.76) secs
                     left PSF ApplyZernikes failed

  12  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:53:35.752 2009  to  Thu Sep 17 02:53:39.615 2009   (  3.86) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  13  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:53:35.959 2009  to  Thu Sep 17 02:53:39.511 2009   (  3.55) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  14  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:39.295 2009  to  Thu Sep 17 02:53:39.458 2009   (  0.16) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  15  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:44.620 2009  to  Thu Sep 17 02:53:44.620 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

  16  FAILED    PSF        command.setInstrumentOffsets                                  Thu Sep 17 02:53:45.011 2009  to  Thu Sep 17 02:53:45.410 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:45.142 2009  to  Thu Sep 17 02:53:45.306 2009   (  0.16) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  18  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Sep 17 02:53:45.091 2009  to  Thu Sep 17 02:53:45.358 2009   (  0.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  19  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:54:29.695 2009  to  Thu Sep 17 02:54:29.695 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

  20  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.053 2009  to  Thu Sep 17 02:54:32.053 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 8.0120564e-04 -5.5253506e-04 -5.2309513e-02 -4.2030334e-02 1.6395569e-02 3.0016422e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.306 2009  to  Thu Sep 17 02:54:32.306 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  22  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.559 2009  to  Thu Sep 17 02:54:32.559 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  23  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.812 2009  to  Thu Sep 17 02:54:32.812 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  24  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.065 2009  to  Thu Sep 17 02:54:33.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.319 2009  to  Thu Sep 17 02:54:33.319 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.1273575e-04 -2.0802021e-04 -5.2521408e-02 -3.4374237e-02 -8.9569092e-03 1.8015385e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.572 2009  to  Thu Sep 17 02:54:33.572 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  27  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.825 2009  to  Thu Sep 17 02:54:33.825 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.078 2009  to  Thu Sep 17 02:54:34.078 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  29  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.331 2009  to  Thu Sep 17 02:54:34.331 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.584 2009  to  Thu Sep 17 02:54:34.584 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.837 2009  to  Thu Sep 17 02:54:34.837 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.090 2009  to  Thu Sep 17 02:54:35.090 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.344 2009  to  Thu Sep 17 02:54:35.344 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  34  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.597 2009  to  Thu Sep 17 02:54:35.597 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  35  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.850 2009  to  Thu Sep 17 02:54:35.850 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  36  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.103 2009  to  Thu Sep 17 02:54:36.103 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  37  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.356 2009  to  Thu Sep 17 02:54:36.356 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  38  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.609 2009  to  Thu Sep 17 02:54:36.609 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.6285343e-04 -2.5713444e-04 -5.2127779e-02 -3.5461426e-02 3.8131714e-02 1.9721031e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.862 2009  to  Thu Sep 17 02:54:36.862 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.6285343e-04 -2.5713444e-04 -5.2127779e-02 -3.5461426e-02 3.8131714e-02 1.9721031e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.114 2009  to  Thu Sep 17 02:54:37.114 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.7438354e-04 8.7380409e-05 -5.2339673e-02 -2.7805328e-02 1.2779236e-02 7.7199936e-03

  41  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.366 2009  to  Thu Sep 17 02:54:37.366 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.7438354e-04 8.7380409e-05 -5.2339673e-02 -2.7805328e-02 1.2779236e-02 7.7199936e-03

  42  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.618 2009  to  Thu Sep 17 02:54:37.618 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  43  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.870 2009  to  Thu Sep 17 02:54:37.870 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  44  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:38.123 2009  to  Thu Sep 17 02:54:38.123 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  45  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:55:27.246 2009  to  Thu Sep 17 02:55:50.418 2009   ( 23.17) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  46  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:55:27.297 2009  to  Thu Sep 17 02:55:50.366 2009   ( 23.07) secs
                     right PSF ApplyZernikes failed

  47  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:55:27.453 2009  to  Thu Sep 17 02:55:50.314 2009   ( 22.86) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:55:32.868 2009  to  Thu Sep 17 02:55:50.261 2009   ( 17.39) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 05:12:01.002 2009  to  Thu Sep 17 05:12:12.661 2009   ( 11.66) secs
                     right PSF ApplyZernikes failed

  50  FAILED    PSF        command.setZernikes                                           Thu Sep 17 05:12:00.952 2009  to  Thu Sep 17 05:12:12.713 2009   ( 11.76) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  51  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 05:12:01.156 2009  to  Thu Sep 17 05:12:12.609 2009   ( 11.45) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 05:12:04.182 2009  to  Thu Sep 17 05:12:12.557 2009   (  8.37) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Sep 16 17:59:44.952 2009  to  Wed Sep 16 17:59:44.952 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Sep 16 17:59:44.957 2009  to  Wed Sep 16 17:59:44.957 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Sep 16 17:59:45.058 2009  to  Wed Sep 16 17:59:45.058 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.073 2009  to  Wed Sep 16 17:59:46.073 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.074 2009  to  Wed Sep 16 17:59:46.074 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.074 2009  to  Wed Sep 16 17:59:46.074 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.075 2009  to  Wed Sep 16 17:59:46.075 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.076 2009  to  Wed Sep 16 17:59:46.076 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.076 2009  to  Wed Sep 16 17:59:46.076 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.077 2009  to  Wed Sep 16 17:59:46.077 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 17:59:46.077 2009  to  Wed Sep 16 17:59:46.077 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    OSS        side[0].swa                                                   Wed Sep 16 17:59:46.520 2009  to  Wed Sep 16 17:59:46.520 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  13  FAILED    OSS        side[1].swa                                                   Wed Sep 16 17:59:49.412 2009  to  Wed Sep 16 17:59:49.412 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  14  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 18:18:35.652 2009  to  Wed Sep 16 18:18:35.652 2009   (  0.00) secs
                     The oss was shut down.

  15  SHUTDOWN  IIF        shutdown                                                      Wed Sep 16 18:26:04.342 2009  to  Wed Sep 16 18:26:04.342 2009   (  0.00) secs
                     IIF subsystem shut down

  16  STARTUP   IIF        startup                                                       Wed Sep 16 18:31:31.504 2009  to  Wed Sep 16 18:31:31.504 2009   (  0.00) secs
                     IIF subsystem started, version 6.12

  17  STARTUP   OSS        startup                                                       Wed Sep 16 20:22:47.420 2009  to  Wed Sep 16 20:22:47.420 2009   (  0.00) secs
                     The oss was started.

  18  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 20:40:11.171 2009  to  Wed Sep 16 20:40:11.171 2009   (  0.00) secs
                     The oss was shut down.

  19  STARTUP   OSS        startup                                                       Wed Sep 16 20:43:26.655 2009  to  Wed Sep 16 20:43:26.655 2009   (  0.00) secs
                     The oss was started.

  20  STARTUP   OSS        side[1].terc.startup.command                                  Wed Sep 16 20:44:10.272 2009  to  Wed Sep 16 20:44:10.272 2009   (  0.00) secs
                     side[1].terc: [startup] command.started

  21  STARTUP   OSS        side[1].terc.startup.command                                  Wed Sep 16 20:44:11.222 2009  to  Wed Sep 16 20:44:11.222 2009   (  0.00) secs
                     side[1].terc: [startup] command.complete

  22  SHUTDOWN  OSS        shutdown                                                      Wed Sep 16 20:46:28.200 2009  to  Wed Sep 16 20:46:28.200 2009   (  0.00) secs
                     The oss was shut down.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.636 2009  to  Wed Sep 16 21:40:54.636 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.636 2009  to  Wed Sep 16 21:40:54.636 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.637 2009  to  Wed Sep 16 21:40:54.637 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.637 2009  to  Wed Sep 16 21:40:54.637 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.638 2009  to  Wed Sep 16 21:40:54.638 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.638 2009  to  Wed Sep 16 21:40:54.638 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.639 2009  to  Wed Sep 16 21:40:54.639 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Sep 16 21:40:54.639 2009  to  Wed Sep 16 21:40:54.639 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 00:40:40.264 2009  to  Thu Sep 17 00:40:40.264 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:52:47.917 2009  to  Thu Sep 17 01:52:47.917 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:53:10.601 2009  to  Thu Sep 17 01:53:10.601 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Sep 17 01:55:27.252 2009  to  Thu Sep 17 01:55:27.252 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  35  FAILED    PSF        primaryMirror.command.clearPositions                          Thu Sep 17 02:52:03.422 2009  to  Thu Sep 17 02:52:09.907 2009   (  6.49) secs
                     left PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

  36  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:03.532 2009  to  Thu Sep 17 02:52:09.796 2009   (  6.26) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:03.474 2009  to  Thu Sep 17 02:52:09.854 2009   (  6.38) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:05.256 2009  to  Thu Sep 17 02:52:11.635 2009   (  6.38) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PSF        primaryMirror.command.clearPositions                          Thu Sep 17 02:52:05.205 2009  to  Thu Sep 17 02:52:11.687 2009   (  6.48) secs
                     right PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

  40  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:05.313 2009  to  Thu Sep 17 02:52:11.577 2009   (  6.26) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  41  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:59.248 2009  to  Thu Sep 17 02:53:39.350 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  42  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:52:59.256 2009  to  Thu Sep 17 02:53:33.239 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:59.195 2009  to  Thu Sep 17 02:53:39.295 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  44  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:52:59.198 2009  to  Thu Sep 17 02:53:33.183 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  45  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:53:29.577 2009  to  Thu Sep 17 02:53:33.611 2009   (  4.03) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

  46  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:53:29.684 2009  to  Thu Sep 17 02:53:33.452 2009   (  3.77) secs
                     right PSF ApplyZernikes failed

  47  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:53:29.632 2009  to  Thu Sep 17 02:53:33.504 2009   (  3.87) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  48  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:53:29.857 2009  to  Thu Sep 17 02:53:33.400 2009   (  3.54) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:33.183 2009  to  Thu Sep 17 02:53:33.347 2009   (  0.16) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:33.239 2009  to  Thu Sep 17 02:53:33.289 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:53:35.692 2009  to  Thu Sep 17 02:53:39.722 2009   (  4.03) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

  52  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:53:35.804 2009  to  Thu Sep 17 02:53:39.563 2009   (  3.76) secs
                     left PSF ApplyZernikes failed

  53  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:53:35.752 2009  to  Thu Sep 17 02:53:39.615 2009   (  3.86) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  54  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:53:35.959 2009  to  Thu Sep 17 02:53:39.511 2009   (  3.55) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:39.350 2009  to  Thu Sep 17 02:53:39.401 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:39.295 2009  to  Thu Sep 17 02:53:39.458 2009   (  0.16) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  57  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:44.562 2009  to  Thu Sep 17 02:53:44.562 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  58  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:44.620 2009  to  Thu Sep 17 02:53:44.620 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

  59  FAILED    IIF        command.moveFocus                                             Thu Sep 17 02:53:44.956 2009  to  Thu Sep 17 02:53:45.568 2009   (  0.61) secs
                     IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  60  FAILED    PSF        command.setInstrumentOffsets                                  Thu Sep 17 02:53:45.011 2009  to  Thu Sep 17 02:53:45.410 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:53:45.142 2009  to  Thu Sep 17 02:53:45.306 2009   (  0.16) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Sep 17 02:53:45.091 2009  to  Thu Sep 17 02:53:45.358 2009   (  0.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:53:45.199 2009  to  Thu Sep 17 02:53:45.249 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:54:29.636 2009  to  Thu Sep 17 02:54:29.636 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  65  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:54:29.695 2009  to  Thu Sep 17 02:54:29.695 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

  66  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.053 2009  to  Thu Sep 17 02:54:32.053 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 8.0120564e-04 -5.5253506e-04 -5.2309513e-02 -4.2030334e-02 1.6395569e-02 3.0016422e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.306 2009  to  Thu Sep 17 02:54:32.306 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  68  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.559 2009  to  Thu Sep 17 02:54:32.559 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  69  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:32.812 2009  to  Thu Sep 17 02:54:32.812 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  70  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.065 2009  to  Thu Sep 17 02:54:33.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3433905e-04 7.9631805e-05 -5.2156091e-02 -5.0136566e-02 7.5454712e-03 -2.6774406e-03

  71  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.319 2009  to  Thu Sep 17 02:54:33.319 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.1273575e-04 -2.0802021e-04 -5.2521408e-02 -3.4374237e-02 -8.9569092e-03 1.8015385e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.572 2009  to  Thu Sep 17 02:54:33.572 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  73  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:33.825 2009  to  Thu Sep 17 02:54:33.825 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  74  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.078 2009  to  Thu Sep 17 02:54:34.078 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4357777e-04 -1.1006594e-03 -5.2710891e-02 -8.6593628e-03 -2.9964447e-02 6.9255233e-03

  75  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.331 2009  to  Thu Sep 17 02:54:34.331 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  76  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.584 2009  to  Thu Sep 17 02:54:34.584 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  77  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:34.837 2009  to  Thu Sep 17 02:54:34.837 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  78  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.090 2009  to  Thu Sep 17 02:54:35.090 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  79  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.344 2009  to  Thu Sep 17 02:54:35.344 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  80  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.597 2009  to  Thu Sep 17 02:54:35.597 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  81  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:35.850 2009  to  Thu Sep 17 02:54:35.850 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  82  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.103 2009  to  Thu Sep 17 02:54:36.103 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  83  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.356 2009  to  Thu Sep 17 02:54:36.356 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2724609e-04 -5.1295757e-04 -5.2714050e-02 -1.7898560e-02 8.5906982e-03 7.1029067e-03

  84  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.609 2009  to  Thu Sep 17 02:54:36.609 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.6285343e-04 -2.5713444e-04 -5.2127779e-02 -3.5461426e-02 3.8131714e-02 1.9721031e-02

  85  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:36.862 2009  to  Thu Sep 17 02:54:36.862 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.6285343e-04 -2.5713444e-04 -5.2127779e-02 -3.5461426e-02 3.8131714e-02 1.9721031e-02

  86  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.114 2009  to  Thu Sep 17 02:54:37.114 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.7438354e-04 8.7380409e-05 -5.2339673e-02 -2.7805328e-02 1.2779236e-02 7.7199936e-03

  87  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.366 2009  to  Thu Sep 17 02:54:37.366 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.7438354e-04 8.7380409e-05 -5.2339673e-02 -2.7805328e-02 1.2779236e-02 7.7199936e-03

  88  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.618 2009  to  Thu Sep 17 02:54:37.618 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  89  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:37.870 2009  to  Thu Sep 17 02:54:37.870 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.9065561e-04 -5.0044060e-04 -5.2336633e-02 -1.8569946e-02 -2.5787354e-02 7.5497627e-03

  90  FAILED    PSF        primaryMirror.positionError                                   Thu Sep 17 02:54:38.123 2009  to  Thu Sep 17 02:54:38.123 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.8889389e-04 -2.1755695e-04 -5.2532315e-02 -1.1329651e-02 3.0330658e-02 -3.1924844e-03

  91  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 02:55:27.096 2009  to  Thu Sep 17 02:55:50.525 2009   ( 23.43) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  92  FAILED    PSF        command.setZernikes                                           Thu Sep 17 02:55:27.246 2009  to  Thu Sep 17 02:55:50.418 2009   ( 23.17) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  93  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 02:55:27.297 2009  to  Thu Sep 17 02:55:50.366 2009   ( 23.07) secs
                     right PSF ApplyZernikes failed

  94  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 02:55:27.453 2009  to  Thu Sep 17 02:55:50.314 2009   ( 22.86) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  95  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 02:55:32.868 2009  to  Thu Sep 17 02:55:50.261 2009   ( 17.39) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  96  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 02:55:32.923 2009  to  Thu Sep 17 02:55:50.203 2009   ( 17.28) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:14.520 2009  to  Thu Sep 17 03:02:14.520 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  98  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:23.859 2009  to  Thu Sep 17 03:02:23.859 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

  99  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:33.194 2009  to  Thu Sep 17 03:02:33.194 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 100  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:42.627 2009  to  Thu Sep 17 03:02:42.627 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 101  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:02:51.835 2009  to  Thu Sep 17 03:02:51.835 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 102  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:00.966 2009  to  Thu Sep 17 03:03:00.966 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 103  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:10.100 2009  to  Thu Sep 17 03:03:10.100 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 104  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:19.265 2009  to  Thu Sep 17 03:03:19.265 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 105  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:28.608 2009  to  Thu Sep 17 03:03:28.608 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 106  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:37.943 2009  to  Thu Sep 17 03:03:37.943 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 107  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:47.191 2009  to  Thu Sep 17 03:03:47.191 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 108  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:03:56.314 2009  to  Thu Sep 17 03:03:56.314 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 109  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:05.660 2009  to  Thu Sep 17 03:04:05.660 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 110  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:14.770 2009  to  Thu Sep 17 03:04:14.770 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 111  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:04:16.188 2009  to  Thu Sep 17 03:04:16.188 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 112  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:04:16.138 2009  to  Thu Sep 17 03:04:16.138 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 113  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:24.039 2009  to  Thu Sep 17 03:04:24.039 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 114  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:33.155 2009  to  Thu Sep 17 03:04:33.155 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 115  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:42.462 2009  to  Thu Sep 17 03:04:42.462 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 116  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:04:51.578 2009  to  Thu Sep 17 03:04:51.578 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 117  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:00.885 2009  to  Thu Sep 17 03:05:00.885 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 118  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:10.247 2009  to  Thu Sep 17 03:05:10.247 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 119  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:19.569 2009  to  Thu Sep 17 03:05:19.569 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 120  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:28.895 2009  to  Thu Sep 17 03:05:28.895 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 121  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:38.178 2009  to  Thu Sep 17 03:05:38.178 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 122  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:48.193 2009  to  Thu Sep 17 03:05:48.193 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 123  FAILED    PCS        guider.telemetryError                                         Thu Sep 17 03:05:57.546 2009  to  Thu Sep 17 03:05:57.546 2009   (  0.00) secs
                     PCS Guider telemetry error: The sample buffer is full

 124  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:07:44.156 2009  to  Thu Sep 17 03:07:44.156 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 125  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:07:44.106 2009  to  Thu Sep 17 03:07:44.106 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 126  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:09:28.078 2009  to  Thu Sep 17 03:09:28.078 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 127  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:09:28.128 2009  to  Thu Sep 17 03:09:28.128 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 128  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:15:03.939 2009  to  Thu Sep 17 03:15:03.939 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 129  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:15:03.990 2009  to  Thu Sep 17 03:15:03.990 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 130  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:25:08.396 2009  to  Thu Sep 17 03:25:08.396 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 131  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:25:08.346 2009  to  Thu Sep 17 03:25:08.346 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 132  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:31:48.271 2009  to  Thu Sep 17 03:31:48.271 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 133  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:31:48.321 2009  to  Thu Sep 17 03:31:48.321 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 134  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:40:11.259 2009  to  Thu Sep 17 03:40:11.259 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 135  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:40:11.208 2009  to  Thu Sep 17 03:40:11.208 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 136  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:44:07.421 2009  to  Thu Sep 17 03:44:07.421 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 137  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:44:07.371 2009  to  Thu Sep 17 03:44:07.371 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 138  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:44:44.301 2009  to  Thu Sep 17 03:44:44.301 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 139  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:44:44.250 2009  to  Thu Sep 17 03:44:44.250 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 140  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:50:02.168 2009  to  Thu Sep 17 03:50:02.168 2009   (  0.00) secs
                     left PMC PMC closing network connection

 141  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:50:02.117 2009  to  Thu Sep 17 03:50:02.117 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

 142  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:51:01.407 2009  to  Thu Sep 17 03:51:01.407 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 143  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:51:01.458 2009  to  Thu Sep 17 03:51:01.458 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 03:57:19.950 2009  to  Thu Sep 17 03:57:19.950 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 145  FAILED    PMC        VxInterface.close                                             Thu Sep 17 03:57:20.000 2009  to  Thu Sep 17 03:57:20.000 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:44:05.720 2009  to  Thu Sep 17 04:44:05.720 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 147  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:44:05.771 2009  to  Thu Sep 17 04:44:05.771 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:47:39.987 2009  to  Thu Sep 17 04:47:39.987 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 149  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:47:40.039 2009  to  Thu Sep 17 04:47:40.039 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 150  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:51:07.955 2009  to  Thu Sep 17 04:51:07.955 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 151  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:51:08.007 2009  to  Thu Sep 17 04:51:08.007 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 152  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 04:54:26.225 2009  to  Thu Sep 17 04:54:26.225 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 153  FAILED    PMC        VxInterface.close                                             Thu Sep 17 04:54:26.275 2009  to  Thu Sep 17 04:54:26.275 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:09:11.589 2009  to  Thu Sep 17 05:09:11.589 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 155  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:09:11.640 2009  to  Thu Sep 17 05:09:11.640 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 156  FAILED    IIF        command.sendWavefront                                         Thu Sep 17 05:12:00.897 2009  to  Thu Sep 17 05:12:12.821 2009   ( 11.92) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 157  FAILED    PSF        command.applyZernikes                                         Thu Sep 17 05:12:01.002 2009  to  Thu Sep 17 05:12:12.661 2009   ( 11.66) secs
                     right PSF ApplyZernikes failed

 158  FAILED    PSF        command.setZernikes                                           Thu Sep 17 05:12:00.952 2009  to  Thu Sep 17 05:12:12.713 2009   ( 11.76) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 159  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Sep 17 05:12:01.156 2009  to  Thu Sep 17 05:12:12.609 2009   ( 11.45) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 160  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Sep 17 05:12:04.182 2009  to  Thu Sep 17 05:12:12.557 2009   (  8.37) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 161  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Sep 17 05:12:04.239 2009  to  Thu Sep 17 05:12:12.500 2009   (  8.26) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 162  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:15:37.430 2009  to  Thu Sep 17 05:15:37.430 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 163  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:15:37.480 2009  to  Thu Sep 17 05:15:37.480 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 164  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:16:16.224 2009  to  Thu Sep 17 05:16:16.224 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 165  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:16:16.275 2009  to  Thu Sep 17 05:16:16.275 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 166  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:15.273 2009  to  Thu Sep 17 05:27:15.273 2009   (  0.00) secs
                     left PMC Mirror closing network connection

 167  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:15.223 2009  to  Thu Sep 17 05:27:15.223 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

 168  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:15.623 2009  to  Thu Sep 17 05:27:15.623 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 169  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:15.693 2009  to  Thu Sep 17 05:27:15.693 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 170  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:27:44.819 2009  to  Thu Sep 17 05:27:44.819 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 171  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:27:44.869 2009  to  Thu Sep 17 05:27:44.869 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 172  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:36:14.091 2009  to  Thu Sep 17 05:36:14.091 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 173  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:36:14.041 2009  to  Thu Sep 17 05:36:14.041 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 174  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:37:20.182 2009  to  Thu Sep 17 05:37:20.182 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 175  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:37:20.130 2009  to  Thu Sep 17 05:37:20.130 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 176  FAILED    PMC        VxInterface.lengthError                                       Thu Sep 17 05:54:59.443 2009  to  Thu Sep 17 05:54:59.443 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 177  FAILED    PMC        VxInterface.close                                             Thu Sep 17 05:54:59.493 2009  to  Thu Sep 17 05:54:59.493 2009   (  0.00) secs
                     right PMC Actuator closing network connection

**********************************************************
    Reporting period ending:   Thu Sep 17 06:34:55.529 2009
********************************************************************************************************

This topic: Software > TCSSWReportFile_090916
Topic revision: 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback