********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Sep 10 2009 to Sep 11 2009
 
    Reporting period beginning:   Thu Sep 10 18:01:05.147 2009
    Reporting period ending:      Fri Sep 11 06:30:59.368 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05     0.0 %          1                     1           
                                                                                                   
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05     0.0 %          1                     1           
                                                                                                   

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Sep 11 00:29:24.622 2009  to  Fri Sep 11 00:29:25.669 2009   (  1.05) secs
                     IIF TCS authorize command started for both LBC at prime focus
                     IIF TCS authorize alert for both LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for both LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.abort                                              Fri Sep 11 05:16:55.306 2009  to  Fri Sep 11 05:16:55.357 2009   (  0.05) secs
                     IIF Abort command started
                     IIF Abort command failed because not waiting for mount
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.03    0.06    0.05    0.19   100.0 %         88         88                      
                                                                       0.03    0.06    0.05    0.19
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.02    0.22    0.20    0.33   100.0 %         71         71                      
                                                                       0.02    0.22    0.20    0.33
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.04    0.17    0.16    0.31   100.0 %         28         28                      
                                                                       0.04    0.17    0.16    0.31
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.74    5.27    1.68   20.73   100.0 %         71         71                      
                                                                       4.74    5.27    1.68   20.73
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   49.19   49.75    6.55  142.45   100.0 %          8          8                      
                                                                      49.19   49.75    6.55  142.45
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   15.61   14.63    1.05   37.11   100.0 %          8          8                      
                                                                      15.61   14.63    1.05   37.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   40.52   17.08    1.05  117.23   100.0 %          8          8                      
                                                                      40.52   17.08    1.05  117.23
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    9.89   10.10    0.56   72.27    99.1 %        111        110          1           
                                                                       9.92   10.16    0.56   72.27

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             4

IIF Events of Interest

   1  FAILED    IIF        command.sendWavefront                                         Fri Sep 11 06:26:13.638 2009  to  Fri Sep 11 06:26:17.768 2009   (  4.13) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1
**********************************************************
AOS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest

   1  STARTUP   AOS        startup                                                       Fri Sep 11 00:28:57.623 2009  to  Fri Sep 11 00:28:57.623 2009   (  0.00) secs
                     AOS subsystem started - AOS Version .
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3844                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  5298                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                  3           
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      24                      

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:37.675 2009  to  Thu Sep 10 21:33:37.675 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:48.266 2009  to  Thu Sep 10 21:33:48.266 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:58.973 2009  to  Thu Sep 10 21:33:58.973 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         11         11                      
                                                                       0.00    0.05    0.05    0.05

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest

   1  STARTUP   GCS        startup                                                       Fri Sep 11 00:28:51.457 2009  to  Fri Sep 11 00:28:51.457 2009   (  0.00) secs
                    

   2  STARTUP   GCS        startup                                                       Fri Sep 11 00:28:51.508 2009  to  Fri Sep 11 00:28:51.508 2009   (  0.00) secs
                    
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      12                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      12                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.error . . . . . . . . . . . . . . . .                 20           
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.HydrostaticBearing.info. . . . . . . . . . . . . . . . .      95                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       4                      
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      87                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            47
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      26                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            24
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             8
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  6           
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.ELDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      10                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             4
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.ELDrive.regen_ok_not . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      68                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  3           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      25                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      29                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .      87                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:03:59.995 2009  to  Thu Sep 10 18:03:59.995 2009   (  0.00) secs
                     2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

   2  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.047 2009  to  Thu Sep 10 18:04:00.047 2009   (  0.00) secs
                     This singleton has not been initialized

   3  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.098 2009  to  Thu Sep 10 18:04:00.098 2009   (  0.00) secs
                     This singleton has not been initialized

   4  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.149 2009  to  Thu Sep 10 18:04:00.149 2009   (  0.00) secs
                     This singleton has not been initialized

   5  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.200 2009  to  Thu Sep 10 18:04:00.200 2009   (  0.00) secs
                     This singleton has not been initialized

   6  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.251 2009  to  Thu Sep 10 18:04:00.251 2009   (  0.00) secs
                     This singleton has not been initialized

   7  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.302 2009  to  Thu Sep 10 18:04:00.302 2009   (  0.00) secs
                     This singleton has not been initialized

   8  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.353 2009  to  Thu Sep 10 18:04:00.353 2009   (  0.00) secs
                     This singleton has not been initialized

   9  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.404 2009  to  Thu Sep 10 18:04:00.404 2009   (  0.00) secs
                     This singleton has not been initialized

  10  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.455 2009  to  Thu Sep 10 18:04:00.455 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_left: This singleton has not been initialized

  11  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.506 2009  to  Thu Sep 10 18:04:00.506 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_left: This singleton has not been initialized

  12  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.557 2009  to  Thu Sep 10 18:04:00.557 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_left: This singleton has not been initialized

  13  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.608 2009  to  Thu Sep 10 18:04:00.608 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_left: This singleton has not been initialized

  14  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.659 2009  to  Thu Sep 10 18:04:00.659 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_right: This singleton has not been initialized

  15  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.710 2009  to  Thu Sep 10 18:04:00.710 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_right: This singleton has not been initialized

  16  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.761 2009  to  Thu Sep 10 18:04:00.761 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_right: This singleton has not been initialized

  17  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.812 2009  to  Thu Sep 10 18:04:00.812 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_right: This singleton has not been initialized

  18  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.863 2009  to  Thu Sep 10 18:04:00.863 2009   (  0.00) secs
                     hbs sys params.variables:This singleton has not been initialized

  19  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.914 2009  to  Thu Sep 10 18:04:00.914 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  20  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.984 2009  to  Thu Sep 10 18:04:00.984 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  21  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:30:22.449 2009  to  Fri Sep 11 00:30:22.449 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  22  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:30:37.200 2009  to  Fri Sep 11 00:30:37.200 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.374 2009  to  Fri Sep 11 00:31:25.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.374 2009  to  Fri Sep 11 00:31:25.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.375 2009  to  Fri Sep 11 00:31:25.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.375 2009  to  Fri Sep 11 00:31:25.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.403 2009  to  Fri Sep 11 00:31:25.403 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.403 2009  to  Fri Sep 11 00:31:25.403 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.404 2009  to  Fri Sep 11 00:31:25.404 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.404 2009  to  Fri Sep 11 00:31:25.404 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:32:43.968 2009  to  Fri Sep 11 00:32:43.968 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:33:01.309 2009  to  Fri Sep 11 00:33:01.309 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:33:39.174 2009  to  Fri Sep 11 00:33:39.174 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:34:25.199 2009  to  Fri Sep 11 00:34:25.199 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  35  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:36:56.495 2009  to  Fri Sep 11 00:36:56.495 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  36  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:37:24.192 2009  to  Fri Sep 11 00:37:24.192 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  37  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:37:56.759 2009  to  Fri Sep 11 00:37:56.759 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  38  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:40:52.772 2009  to  Fri Sep 11 00:40:52.772 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:40:52.910 2009  to  Fri Sep 11 00:40:52.910 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 01:04:47.111 2009  to  Fri Sep 11 01:04:47.111 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Sep 11 05:07:30.132 2009  to  Fri Sep 11 05:07:30.132 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Sep 11 05:07:30.134 2009  to  Fri Sep 11 05:07:30.134 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].terc.getfocalstationcount.command. . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     side[0].terc.homemirror.command. . . . . . . . . . . . . . . .    0.00   20.43   20.43   20.43   100.0 %          1          1                      
                                                                       0.00   20.43   20.43   20.43
     side[0].terc.homesel.command . . . . . . . . . . . . . . . . .    0.00   83.61   83.61   83.61   100.0 %          1          1                      
                                                                       0.00   83.61   83.61   83.61
     side[0].terc.init.command. . . . . . . . . . . . . . . . . . .    0.00   88.96   88.96   88.96   100.0 %          1          1                      
                                                                       0.00   88.96   88.96   88.96
     side[0].terc.movefocalstation.command. . . . . . . . . . . . .    0.00   47.78   47.78   47.78   100.0 %          1          1                      
                                                                       0.00   47.78   47.78   47.78

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].terc . . . . . . . . . . . . . . . . . . . . . . . . .       2                     3
     side[0].swa. . . . . . . . . . . . . . . . . . . . . . . . . .       1          1           
     side[1].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                  1          1
     tel.notify_connected . . . . . . . . . . . . . . . . . . . . .       5                      

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Thu Sep 10 22:34:20.750 2009  to  Thu Sep 10 22:34:20.750 2009   (  0.00) secs
                     The oss was started.

   2  STARTUP   OSS        side[0].terc.startup.command                                  Thu Sep 10 22:39:13.820 2009  to  Thu Sep 10 22:39:13.820 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

   3  STARTUP   OSS        side[0].terc.startup.command                                  Thu Sep 10 22:39:14.797 2009  to  Thu Sep 10 22:39:14.797 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

   4  FAILED    OSS        side[0].swa                                                   Fri Sep 11 00:31:25.846 2009  to  Fri Sep 11 00:31:25.846 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

   5  FAILED    OSS        side[1].swa                                                   Fri Sep 11 00:31:25.851 2009  to  Fri Sep 11 00:31:25.851 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         28         28                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.getRotatorTrajectory . . . . . . . . . . . .    0.00    0.09    0.08    0.10   100.0 %         71         71                      
                                                                       0.00    0.09    0.08    0.10
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.01    0.05    0.04    0.05   100.0 %          3          3                      
                                                                       0.01    0.05    0.04    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.01    0.06    0.05    0.08   100.0 %         12         12                      
                                                                       0.01    0.06    0.05    0.08
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.24    0.60    0.31    0.82   100.0 %         12         12                      
                                                                       0.24    0.60    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06     0.0 %          1                     1           
                                                                                                   

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .       9                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Fri Sep 11 00:28:36.506 2009  to  Fri Sep 11 00:28:36.506 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5HybridC

   2  FAILED    PCS        telescope.command.stopTracking                                Fri Sep 11 00:29:24.792 2009  to  Fri Sep 11 00:29:24.854 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SHUTDOWN  PCS        shutdown                                                      Fri Sep 11 05:07:29.234 2009  to  Fri Sep 11 05:07:29.234 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.5HybridC

   4  STARTUP   PCS        startup                                                       Fri Sep 11 05:08:14.517 2009  to  Fri Sep 11 05:08:14.517 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5Hybrid
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          1          1                      
                                                                       0.00    1.05    1.05    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.78    2.76    2.05    5.06   100.0 %         87         87                      
                                                                       0.78    2.76    2.05    5.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.50    2.80    2.05    5.06   100.0 %          4          4                      
                                                                       1.50    2.80    2.05    5.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.06    5.06    5.06   100.0 %          1          1                      
                                                                       0.00    5.06    5.06    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.15   66.15   66.15   100.0 %          1          1                      
                                                                       0.00   66.15   66.15   66.15
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   10.25    7.31    0.00   68.36    99.5 %        202        201          1           
                                                                      10.27    7.39    1.25   68.36
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  218.57  218.57  218.57   100.0 %          1          1                      
                                                                       0.00  218.57  218.57  218.57
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.14    0.14    0.14   100.0 %          1          1                      
                                                                       0.00    0.14    0.14    0.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      25                      
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .     334                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            12
     servoLoop.upperLimit.exceeded. . . . . . . . . . . . . . . . .                             1
     servoLoop.iUpperLimit.exceeded . . . . . . . . . . . . . . . .                             1
     mirror.position.Y.exceeded . . . . . . . . . . . . . . . . . .                             1
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                             2
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                             2
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             3
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                             1
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            22
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            55
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
 *** servoLoop.telemetryError . . . . . . . . . . . . . . . . . . .                517           
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       4                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  5           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  5           
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      87                      

PMC Events of Interest

   1  STARTUP   PMC        startup                                                       Thu Sep 10 21:33:06.001 2009  to  Thu Sep 10 21:33:06.001 2009   (  0.00) secs
                     left PMC subsystem started, version 5.1

   2  FAILED    PMC        mirror.panic                                                  Thu Sep 10 21:33:30.944 2009  to  Thu Sep 10 21:33:30.944 2009   (  0.00) secs
                     left PMC ** PANIC: Outer loop stalled

   3  STARTUP   PMC        startup                                                       Thu Sep 10 21:34:03.349 2009  to  Thu Sep 10 21:34:03.349 2009   (  0.00) secs
                     right PMC subsystem started, version 5.1

   4  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.127 2009  to  Thu Sep 10 23:59:32.127 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

   5  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.163 2009  to  Thu Sep 10 23:59:32.163 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

   6  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.285 2009  to  Thu Sep 10 23:59:32.285 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

   7  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.319 2009  to  Thu Sep 10 23:59:32.319 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

   8  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.441 2009  to  Thu Sep 10 23:59:32.441 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

   9  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.474 2009  to  Thu Sep 10 23:59:32.474 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  10  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.596 2009  to  Thu Sep 10 23:59:32.596 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  11  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.629 2009  to  Thu Sep 10 23:59:32.629 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  12  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.752 2009  to  Thu Sep 10 23:59:32.752 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  13  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.785 2009  to  Thu Sep 10 23:59:32.785 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  14  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.908 2009  to  Thu Sep 10 23:59:32.908 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  15  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.940 2009  to  Thu Sep 10 23:59:32.940 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  16  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.100 2009  to  Thu Sep 10 23:59:33.100 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  17  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.101 2009  to  Thu Sep 10 23:59:33.101 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  18  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.255 2009  to  Thu Sep 10 23:59:33.255 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  19  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.257 2009  to  Thu Sep 10 23:59:33.257 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  20  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.409 2009  to  Thu Sep 10 23:59:33.409 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  21  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.412 2009  to  Thu Sep 10 23:59:33.412 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  22  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.563 2009  to  Thu Sep 10 23:59:33.563 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  23  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.566 2009  to  Thu Sep 10 23:59:33.566 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  24  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.718 2009  to  Thu Sep 10 23:59:33.718 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  25  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.721 2009  to  Thu Sep 10 23:59:33.721 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  26  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.873 2009  to  Thu Sep 10 23:59:33.873 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  27  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.875 2009  to  Thu Sep 10 23:59:33.875 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  28  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:34.027 2009  to  Thu Sep 10 23:59:34.027 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  29  FAILED    PMC        VxInterface.close                                             Fri Sep 11 01:10:27.937 2009  to  Fri Sep 11 01:10:27.937 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 01:10:27.887 2009  to  Fri Sep 11 01:10:27.887 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.close                                             Fri Sep 11 04:25:16.126 2009  to  Fri Sep 11 04:25:16.126 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 04:25:16.076 2009  to  Fri Sep 11 04:25:16.076 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Fri Sep 11 05:30:23.729 2009  to  Fri Sep 11 05:30:23.729 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 05:30:23.678 2009  to  Fri Sep 11 05:30:23.678 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 05:47:09.311 2009  to  Fri Sep 11 05:47:09.311 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Fri Sep 11 05:47:09.362 2009  to  Fri Sep 11 05:47:09.362 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 06:12:38.288 2009  to  Fri Sep 11 06:12:38.288 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        VxInterface.close                                             Fri Sep 11 06:12:38.338 2009  to  Fri Sep 11 06:12:38.338 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  39  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:25:52.153 2009  to  Fri Sep 11 06:26:17.391 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:26:17.391 2009  to  Fri Sep 11 06:26:17.442 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  41  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:26:20.462 2009  to  Fri Sep 11 06:26:20.462 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    9.89    9.87    0.34   72.06    99.1 %        111        110          1           
                                                                       9.92    9.93    0.34   72.06
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         16         16                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.74    5.16    1.57   20.62   100.0 %         71         71                      
                                                                       4.74    5.16    1.57   20.62
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.48    0.48    0.48   100.0 %          1          1                      
                                                                       0.00    0.48    0.48    0.48
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    9.89    9.98    0.44   72.16    99.1 %        111        110          1           
                                                                       9.92   10.04    0.44   72.16
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    9.95    9.79    0.13   71.85    99.1 %        112        111          1           
                                                                       9.97    9.85    0.13   71.85
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   10.25    7.44    0.00   68.47    99.5 %        202        201          1           
                                                                      10.27    7.51    1.36   68.47
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.68    3.27    2.16    5.73   100.0 %          4          4                      
                                                                       1.68    3.27    2.16    5.73
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.12    0.10    0.06    1.27   100.0 %        189        189                      
                                                                       0.12    0.10    0.06    1.27
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.11    0.14    0.05    0.29    80.0 %          5          4          1           
                                                                       0.09    0.10    0.05    0.23
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.22    0.85    0.70    1.01   100.0 %          2          2                      
                                                                       0.22    0.85    0.70    1.01
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   24.81   48.51   30.97   66.05   100.0 %          2          2                      
                                                                      24.81   48.51   30.97   66.05
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.74    5.05    1.46   20.52   100.0 %         71         71                      
                                                                       4.74    5.05    1.46   20.52
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00   20.50   20.50   20.50   100.0 %          1          1                      
                                                                       0.00   20.50   20.50   20.50
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.02    0.05    0.05    0.18   100.0 %        112        112                      
                                                                       0.02    0.05    0.05    0.18
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.14    0.74    0.64    0.83   100.0 %          2          2                      
                                                                       0.14    0.74    0.64    0.83
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.17    0.28    0.08    0.42   100.0 %          3          3                      
                                                                       0.17    0.28    0.08    0.42
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.04    0.12    0.10    0.15   100.0 %          2          2                      
                                                                       0.04    0.12    0.10    0.15
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.12    0.20    0.06    0.30   100.0 %          3          3                      
                                                                       0.12    0.20    0.06    0.30

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                 42           

PSF Events of Interest

   1  STARTUP   PSF        startup                                                       Fri Sep 11 00:28:44.561 2009  to  Fri Sep 11 00:28:44.561 2009   (  0.00) secs
                     left PSF subsystem started, version 4.37

   2  STARTUP   PSF        startup                                                       Fri Sep 11 00:44:59.207 2009  to  Fri Sep 11 00:44:59.207 2009   (  0.00) secs
                     right PSF subsystem started, version 4.37

   3  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Sep 11 00:45:02.723 2009  to  Fri Sep 11 00:45:03.011 2009   (  0.29) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   4  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 05:27:34.420 2009  to  Fri Sep 11 05:27:34.420 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0862947e-04 1.1759996e-03 6.7561865e-04 -1.5361786e-02 1.5801239e-01 -2.0841837e-02

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:25:52.096 2009  to  Fri Sep 11 06:26:17.335 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  FAILED    PSF        command.setZernikes                                           Fri Sep 11 06:26:13.790 2009  to  Fri Sep 11 06:26:17.660 2009   (  3.87) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

   7  FAILED    PSF        command.applyZernikes                                         Fri Sep 11 06:26:13.842 2009  to  Fri Sep 11 06:26:17.608 2009   (  3.77) secs
                     right PSF ApplyZernikes failed

   8  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Sep 11 06:26:13.998 2009  to  Fri Sep 11 06:26:17.555 2009   (  3.56) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:26:17.335 2009  to  Fri Sep 11 06:26:17.503 2009   (  0.17) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:26:20.524 2009  to  Fri Sep 11 06:26:20.524 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

  11  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:22.846 2009  to  Fri Sep 11 06:26:22.846 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  12  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.099 2009  to  Fri Sep 11 06:26:23.099 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  13  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.352 2009  to  Fri Sep 11 06:26:23.352 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.606 2009  to  Fri Sep 11 06:26:23.606 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  15  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.859 2009  to  Fri Sep 11 06:26:23.859 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  16  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.112 2009  to  Fri Sep 11 06:26:24.112 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.366 2009  to  Fri Sep 11 06:26:24.366 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  18  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.619 2009  to  Fri Sep 11 06:26:24.619 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  19  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.873 2009  to  Fri Sep 11 06:26:24.873 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  20  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.126 2009  to  Fri Sep 11 06:26:25.126 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  21  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.379 2009  to  Fri Sep 11 06:26:25.379 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  22  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.632 2009  to  Fri Sep 11 06:26:25.632 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -9.8437071e-05 -1.2588501e-03 -4.4431686e-02 5.1306248e-02 -1.2354851e-02 1.3805926e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.885 2009  to  Fri Sep 11 06:26:25.885 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -9.8437071e-05 -1.2588501e-03 -4.4431686e-02 5.1306248e-02 -1.2354851e-02 1.3805926e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.138 2009  to  Fri Sep 11 06:26:26.138 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.389 2009  to  Fri Sep 11 06:26:26.389 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

  26  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.643 2009  to  Fri Sep 11 06:26:26.643 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.896 2009  to  Fri Sep 11 06:26:26.896 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.164 2009  to  Fri Sep 11 06:26:27.164 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  29  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.417 2009  to  Fri Sep 11 06:26:27.417 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.670 2009  to  Fri Sep 11 06:26:27.670 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.5144558e-04 -6.6900253e-04 -4.4612706e-02 -3.7779808e-03 -1.7122984e-02 3.0242801e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.924 2009  to  Fri Sep 11 06:26:27.924 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.5144558e-04 -6.6900253e-04 -4.4612706e-02 -3.7779808e-03 -1.7122984e-02 3.0242801e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.177 2009  to  Fri Sep 11 06:26:28.177 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.4759769e-04 -6.6912174e-04 -4.4235349e-02 -4.1122437e-03 -6.3626766e-03 3.1800121e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.430 2009  to  Fri Sep 11 06:26:28.430 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.4759769e-04 -6.6912174e-04 -4.4235349e-02 -4.1122437e-03 -6.3626766e-03 3.1800121e-03

  34  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.683 2009  to  Fri Sep 11 06:26:28.683 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.6038628e-04 -6.5249205e-04 -4.4618011e-02 1.9002914e-02 2.2636414e-02 2.4360031e-02
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:03:59.995 2009  to  Thu Sep 10 18:03:59.995 2009   (  0.00) secs
                     2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

   2  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.047 2009  to  Thu Sep 10 18:04:00.047 2009   (  0.00) secs
                     This singleton has not been initialized

   3  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.098 2009  to  Thu Sep 10 18:04:00.098 2009   (  0.00) secs
                     This singleton has not been initialized

   4  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.149 2009  to  Thu Sep 10 18:04:00.149 2009   (  0.00) secs
                     This singleton has not been initialized

   5  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.200 2009  to  Thu Sep 10 18:04:00.200 2009   (  0.00) secs
                     This singleton has not been initialized

   6  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.251 2009  to  Thu Sep 10 18:04:00.251 2009   (  0.00) secs
                     This singleton has not been initialized

   7  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.302 2009  to  Thu Sep 10 18:04:00.302 2009   (  0.00) secs
                     This singleton has not been initialized

   8  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.353 2009  to  Thu Sep 10 18:04:00.353 2009   (  0.00) secs
                     This singleton has not been initialized

   9  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.404 2009  to  Thu Sep 10 18:04:00.404 2009   (  0.00) secs
                     This singleton has not been initialized

  10  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.455 2009  to  Thu Sep 10 18:04:00.455 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_left: This singleton has not been initialized

  11  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.506 2009  to  Thu Sep 10 18:04:00.506 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_left: This singleton has not been initialized

  12  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.557 2009  to  Thu Sep 10 18:04:00.557 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_left: This singleton has not been initialized

  13  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.608 2009  to  Thu Sep 10 18:04:00.608 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_left: This singleton has not been initialized

  14  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.659 2009  to  Thu Sep 10 18:04:00.659 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_right: This singleton has not been initialized

  15  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.710 2009  to  Thu Sep 10 18:04:00.710 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_right: This singleton has not been initialized

  16  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.761 2009  to  Thu Sep 10 18:04:00.761 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_right: This singleton has not been initialized

  17  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.812 2009  to  Thu Sep 10 18:04:00.812 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_right: This singleton has not been initialized

  18  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.863 2009  to  Thu Sep 10 18:04:00.863 2009   (  0.00) secs
                     hbs sys params.variables:This singleton has not been initialized

  19  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.914 2009  to  Thu Sep 10 18:04:00.914 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  20  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Thu Sep 10 18:04:00.984 2009  to  Thu Sep 10 18:04:00.984 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  21  STARTUP   PMC        startup                                                       Thu Sep 10 21:33:06.001 2009  to  Thu Sep 10 21:33:06.001 2009   (  0.00) secs
                     left PMC subsystem started, version 5.1

  22  FAILED    PMC        mirror.panic                                                  Thu Sep 10 21:33:30.944 2009  to  Thu Sep 10 21:33:30.944 2009   (  0.00) secs
                     left PMC ** PANIC: Outer loop stalled

  23  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:37.675 2009  to  Thu Sep 10 21:33:37.675 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  24  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:48.266 2009  to  Thu Sep 10 21:33:48.266 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  25  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Sep 10 21:33:58.973 2009  to  Thu Sep 10 21:33:58.973 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  26  STARTUP   PMC        startup                                                       Thu Sep 10 21:34:03.349 2009  to  Thu Sep 10 21:34:03.349 2009   (  0.00) secs
                     right PMC subsystem started, version 5.1

  27  STARTUP   OSS        startup                                                       Thu Sep 10 22:34:20.750 2009  to  Thu Sep 10 22:34:20.750 2009   (  0.00) secs
                     The oss was started.

  28  STARTUP   OSS        side[0].terc.startup.command                                  Thu Sep 10 22:39:13.820 2009  to  Thu Sep 10 22:39:13.820 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

  29  STARTUP   OSS        side[0].terc.startup.command                                  Thu Sep 10 22:39:14.797 2009  to  Thu Sep 10 22:39:14.797 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

  30  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.127 2009  to  Thu Sep 10 23:59:32.127 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  31  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.163 2009  to  Thu Sep 10 23:59:32.163 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  32  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.285 2009  to  Thu Sep 10 23:59:32.285 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  33  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.319 2009  to  Thu Sep 10 23:59:32.319 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  34  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.441 2009  to  Thu Sep 10 23:59:32.441 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  35  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.474 2009  to  Thu Sep 10 23:59:32.474 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  36  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.596 2009  to  Thu Sep 10 23:59:32.596 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  37  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.629 2009  to  Thu Sep 10 23:59:32.629 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  38  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.752 2009  to  Thu Sep 10 23:59:32.752 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  39  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.785 2009  to  Thu Sep 10 23:59:32.785 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  40  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.908 2009  to  Thu Sep 10 23:59:32.908 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  41  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:32.940 2009  to  Thu Sep 10 23:59:32.940 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  42  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.100 2009  to  Thu Sep 10 23:59:33.100 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  43  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.101 2009  to  Thu Sep 10 23:59:33.101 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  44  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.255 2009  to  Thu Sep 10 23:59:33.255 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  45  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.257 2009  to  Thu Sep 10 23:59:33.257 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  46  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.409 2009  to  Thu Sep 10 23:59:33.409 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  47  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.412 2009  to  Thu Sep 10 23:59:33.412 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  48  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.563 2009  to  Thu Sep 10 23:59:33.563 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  49  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.566 2009  to  Thu Sep 10 23:59:33.566 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  50  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.718 2009  to  Thu Sep 10 23:59:33.718 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  51  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.721 2009  to  Thu Sep 10 23:59:33.721 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  52  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.873 2009  to  Thu Sep 10 23:59:33.873 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  53  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:33.875 2009  to  Thu Sep 10 23:59:33.875 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: The sample buffer is full

  54  FAILED    PMC        servoLoop.telemetryError                                      Thu Sep 10 23:59:34.027 2009  to  Thu Sep 10 23:59:34.027 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: The sample buffer is full

  55  STARTUP   PCS        startup                                                       Fri Sep 11 00:28:36.506 2009  to  Fri Sep 11 00:28:36.506 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5HybridC

  56  STARTUP   PSF        startup                                                       Fri Sep 11 00:28:44.561 2009  to  Fri Sep 11 00:28:44.561 2009   (  0.00) secs
                     left PSF subsystem started, version 4.37

  57  STARTUP   GCS        startup                                                       Fri Sep 11 00:28:51.457 2009  to  Fri Sep 11 00:28:51.457 2009   (  0.00) secs
                    

  58  STARTUP   GCS        startup                                                       Fri Sep 11 00:28:51.508 2009  to  Fri Sep 11 00:28:51.508 2009   (  0.00) secs
                    

  59  STARTUP   AOS        startup                                                       Fri Sep 11 00:28:57.623 2009  to  Fri Sep 11 00:28:57.623 2009   (  0.00) secs
                     AOS subsystem started - AOS Version .

  60  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Sep 11 00:29:24.622 2009  to  Fri Sep 11 00:29:25.669 2009   (  1.05) secs
                     IIF TCS authorize command started for both LBC at prime focus
                     IIF TCS authorize alert for both LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for both LBC at prime focus

  61  FAILED    PCS        telescope.command.stopTracking                                Fri Sep 11 00:29:24.792 2009  to  Fri Sep 11 00:29:24.854 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  62  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:30:22.449 2009  to  Fri Sep 11 00:30:22.449 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  63  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:30:37.200 2009  to  Fri Sep 11 00:30:37.200 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  64  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.374 2009  to  Fri Sep 11 00:31:25.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.374 2009  to  Fri Sep 11 00:31:25.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.375 2009  to  Fri Sep 11 00:31:25.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.375 2009  to  Fri Sep 11 00:31:25.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.403 2009  to  Fri Sep 11 00:31:25.403 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.403 2009  to  Fri Sep 11 00:31:25.403 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.404 2009  to  Fri Sep 11 00:31:25.404 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Sep 11 00:31:25.404 2009  to  Fri Sep 11 00:31:25.404 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    OSS        side[0].swa                                                   Fri Sep 11 00:31:25.846 2009  to  Fri Sep 11 00:31:25.846 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  73  FAILED    OSS        side[1].swa                                                   Fri Sep 11 00:31:25.851 2009  to  Fri Sep 11 00:31:25.851 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  74  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:32:43.968 2009  to  Fri Sep 11 00:32:43.968 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  75  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:33:01.309 2009  to  Fri Sep 11 00:33:01.309 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  76  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 00:33:39.174 2009  to  Fri Sep 11 00:33:39.174 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  77  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:34:25.199 2009  to  Fri Sep 11 00:34:25.199 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  78  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:36:56.495 2009  to  Fri Sep 11 00:36:56.495 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  79  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:37:24.192 2009  to  Fri Sep 11 00:37:24.192 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  80  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Sep 11 00:37:56.759 2009  to  Fri Sep 11 00:37:56.759 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  81  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:40:52.772 2009  to  Fri Sep 11 00:40:52.772 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  82  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Sep 11 00:40:52.910 2009  to  Fri Sep 11 00:40:52.910 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  83  STARTUP   PSF        startup                                                       Fri Sep 11 00:44:59.207 2009  to  Fri Sep 11 00:44:59.207 2009   (  0.00) secs
                     right PSF subsystem started, version 4.37

  84  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Sep 11 00:45:02.723 2009  to  Fri Sep 11 00:45:03.011 2009   (  0.29) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  85  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Sep 11 01:04:47.111 2009  to  Fri Sep 11 01:04:47.111 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  86  FAILED    PMC        VxInterface.close                                             Fri Sep 11 01:10:27.937 2009  to  Fri Sep 11 01:10:27.937 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  87  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 01:10:27.887 2009  to  Fri Sep 11 01:10:27.887 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  88  FAILED    PMC        VxInterface.close                                             Fri Sep 11 04:25:16.126 2009  to  Fri Sep 11 04:25:16.126 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  89  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 04:25:16.076 2009  to  Fri Sep 11 04:25:16.076 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  90  SHUTDOWN  PCS        shutdown                                                      Fri Sep 11 05:07:29.234 2009  to  Fri Sep 11 05:07:29.234 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.5HybridC

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Sep 11 05:07:30.132 2009  to  Fri Sep 11 05:07:30.132 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Sep 11 05:07:30.134 2009  to  Fri Sep 11 05:07:30.134 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  93  STARTUP   PCS        startup                                                       Fri Sep 11 05:08:14.517 2009  to  Fri Sep 11 05:08:14.517 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5Hybrid

  94  FAILED    IIF GUI    IIFCommand.abort                                              Fri Sep 11 05:16:55.306 2009  to  Fri Sep 11 05:16:55.357 2009   (  0.05) secs
                     IIF Abort command started
                     IIF Abort command failed because not waiting for mount

  95  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 05:27:34.420 2009  to  Fri Sep 11 05:27:34.420 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0862947e-04 1.1759996e-03 6.7561865e-04 -1.5361786e-02 1.5801239e-01 -2.0841837e-02

  96  FAILED    PMC        VxInterface.close                                             Fri Sep 11 05:30:23.729 2009  to  Fri Sep 11 05:30:23.729 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  97  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 05:30:23.678 2009  to  Fri Sep 11 05:30:23.678 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  98  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 05:47:09.311 2009  to  Fri Sep 11 05:47:09.311 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  99  FAILED    PMC        VxInterface.close                                             Fri Sep 11 05:47:09.362 2009  to  Fri Sep 11 05:47:09.362 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 100  FAILED    PMC        VxInterface.lengthError                                       Fri Sep 11 06:12:38.288 2009  to  Fri Sep 11 06:12:38.288 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 101  FAILED    PMC        VxInterface.close                                             Fri Sep 11 06:12:38.338 2009  to  Fri Sep 11 06:12:38.338 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 102  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:25:52.096 2009  to  Fri Sep 11 06:26:17.335 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 103  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:25:52.153 2009  to  Fri Sep 11 06:26:17.391 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 104  FAILED    IIF        command.sendWavefront                                         Fri Sep 11 06:26:13.638 2009  to  Fri Sep 11 06:26:17.768 2009   (  4.13) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

 105  FAILED    PSF        command.setZernikes                                           Fri Sep 11 06:26:13.790 2009  to  Fri Sep 11 06:26:17.660 2009   (  3.87) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 106  FAILED    PSF        command.applyZernikes                                         Fri Sep 11 06:26:13.842 2009  to  Fri Sep 11 06:26:17.608 2009   (  3.77) secs
                     right PSF ApplyZernikes failed

 107  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Sep 11 06:26:13.998 2009  to  Fri Sep 11 06:26:17.555 2009   (  3.56) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 108  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:26:17.335 2009  to  Fri Sep 11 06:26:17.503 2009   (  0.17) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     right PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 109  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:26:17.391 2009  to  Fri Sep 11 06:26:17.442 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 110  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Sep 11 06:26:20.462 2009  to  Fri Sep 11 06:26:20.462 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

 111  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Sep 11 06:26:20.524 2009  to  Fri Sep 11 06:26:20.524 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete with argument 0.0000000e+00

 112  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:22.846 2009  to  Fri Sep 11 06:26:22.846 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 113  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.099 2009  to  Fri Sep 11 06:26:23.099 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 114  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.352 2009  to  Fri Sep 11 06:26:23.352 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

 115  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.606 2009  to  Fri Sep 11 06:26:23.606 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 116  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:23.859 2009  to  Fri Sep 11 06:26:23.859 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 117  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.112 2009  to  Fri Sep 11 06:26:24.112 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 118  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.366 2009  to  Fri Sep 11 06:26:24.366 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 119  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.619 2009  to  Fri Sep 11 06:26:24.619 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 120  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:24.873 2009  to  Fri Sep 11 06:26:24.873 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 121  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.126 2009  to  Fri Sep 11 06:26:25.126 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 122  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.379 2009  to  Fri Sep 11 06:26:25.379 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 123  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.632 2009  to  Fri Sep 11 06:26:25.632 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -9.8437071e-05 -1.2588501e-03 -4.4431686e-02 5.1306248e-02 -1.2354851e-02 1.3805926e-02

 124  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:25.885 2009  to  Fri Sep 11 06:26:25.885 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -9.8437071e-05 -1.2588501e-03 -4.4431686e-02 5.1306248e-02 -1.2354851e-02 1.3805926e-02

 125  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.138 2009  to  Fri Sep 11 06:26:26.138 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 126  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.389 2009  to  Fri Sep 11 06:26:26.389 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.0448694e-04 -6.6107512e-04 -4.4425428e-02 1.9009590e-02 -1.1782169e-02 -7.5858235e-03

 127  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.643 2009  to  Fri Sep 11 06:26:26.643 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

 128  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:26.896 2009  to  Fri Sep 11 06:26:26.896 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.3025951e-04 -9.6291304e-04 -4.4427037e-02 1.2102127e-02 -2.0718575e-04 1.3542235e-02

 129  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.164 2009  to  Fri Sep 11 06:26:27.164 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 130  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.417 2009  to  Fri Sep 11 06:26:27.417 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.8327107e-04 -9.5498562e-04 -4.4239700e-02 3.4889698e-02 5.1336288e-03 2.9321313e-03

 131  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.670 2009  to  Fri Sep 11 06:26:27.670 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.5144558e-04 -6.6900253e-04 -4.4612706e-02 -3.7779808e-03 -1.7122984e-02 3.0242801e-03

 132  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:27.924 2009  to  Fri Sep 11 06:26:27.924 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.5144558e-04 -6.6900253e-04 -4.4612706e-02 -3.7779808e-03 -1.7122984e-02 3.0242801e-03

 133  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.177 2009  to  Fri Sep 11 06:26:28.177 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.4759769e-04 -6.6912174e-04 -4.4235349e-02 -4.1122437e-03 -6.3626766e-03 3.1800121e-03

 134  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.430 2009  to  Fri Sep 11 06:26:28.430 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.4759769e-04 -6.6912174e-04 -4.4235349e-02 -4.1122437e-03 -6.3626766e-03 3.1800121e-03

 135  FAILED    PSF        primaryMirror.positionError                                   Fri Sep 11 06:26:28.683 2009  to  Fri Sep 11 06:26:28.683 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.6038628e-04 -6.5249205e-04 -4.4618011e-02 1.9002914e-02 2.2636414e-02 2.4360031e-02

**********************************************************
    Reporting period ending:   Fri Sep 11 06:30:59.368 2009
********************************************************************************************************

This topic: Software > TCSSWReportFile_090910
Topic revision: 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback