    TCS Software Performance Report
 
    Observing Night:   Sep 6 2009 to Sep 7 2009
 
    Reporting period beginning:   Sun Sep  6 18:07:09.337 2009
    Reporting period ending:      Mon Sep  7 06:28:58.116 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   13.11    7.38    0.00   39.23    85.7 %         14         12          2           
                                                                      14.62    8.66    0.05   39.23

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Sep  7 00:29:51.217 2009  to  Mon Sep  7 00:29:55.291 2009   (  4.07) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: side[0].terc: [moveFocalStation.moveSelAbs] UMAC is not connected
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   2  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:57:59.704 2009  to  Mon Sep  7 04:58:03.726 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at bentGregorianFront focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:58:03.726 2009  to  Mon Sep  7 04:58:07.696 2009   (  3.97) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: side[0].terc: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   4  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:58:21.820 2009  to  Mon Sep  7 04:58:21.820 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left IRTC at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command. . . . . . . . . . . . . . . . . . . . . . . . . . . .                                    85.7 %                                              notAuthorized =     1
                                                                                                   
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   27.00   44.93    2.93   78.47    80.0 %          5          4          1           
                                                                      15.40   55.43   46.20   78.47
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   24.64   64.96   41.75   93.67    83.3 %          6          3          1          2
                                                                      28.50   60.92   41.75   93.67
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   20.73   39.47   24.81   54.13    33.3 %          3                     2          1
                                                                                                   
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    8.84    6.99    1.05   30.10   100.0 %         13         13                      
                                                                       8.84    6.99    1.05   30.10
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   10.17    7.34    2.06   30.10   100.0 %         11         11                      
                                                                      10.17    7.34    2.06   30.10

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             4

IIF Events of Interest

   1  FAILED    IIF        command.preset.(GUIDE)                                        Mon Sep  7 02:09:38.151 2009  to  Mon Sep  7 02:10:32.279 2009   ( 54.13) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset alert for left IRTC mode GUIDE: side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   2  FAILED    IIF        command.preset.(GUIDE)                                        Mon Sep  7 02:47:04.332 2009  to  Mon Sep  7 02:47:29.144 2009   ( 24.81) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   3  STARTUP   IIF        startup                                                       Mon Sep  7 03:53:17.393 2009  to  Mon Sep  7 03:53:17.393 2009   (  0.00) secs
                     IIF subsystem started, version 6.11

   4  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon Sep  7 05:33:39.222 2009  to  Mon Sep  7 05:33:42.148 2009   (  2.93) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGw command status: AGW3: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGw command status: AGW3: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.860029, -4.05317, 35.2853 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   5  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Sep  7 06:01:52.339 2009  to  Mon Sep  7 06:03:09.439 2009   ( 77.10) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 364
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3393                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6750                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      66                      
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 18           
     weatherStation.noWeatherData . . . . . . . . . . . . . . . . .                  1           

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:09.005 2009  to  Mon Sep  7 03:54:09.005 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        weatherStation.noWeatherData                                  Mon Sep  7 03:54:19.537 2009  to  Mon Sep  7 03:54:19.537 2009   (  0.00) secs
                     Stale or no data being received from SMT.

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:19.819 2009  to  Mon Sep  7 03:54:19.819 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   4  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:30.397 2009  to  Mon Sep  7 03:54:30.397 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   5  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:41.277 2009  to  Mon Sep  7 03:54:41.277 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:51.688 2009  to  Mon Sep  7 03:54:51.688 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:02.403 2009  to  Mon Sep  7 03:55:02.403 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:13.053 2009  to  Mon Sep  7 03:55:13.053 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   9  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:23.672 2009  to  Mon Sep  7 03:55:23.672 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:34.381 2009  to  Mon Sep  7 03:55:34.381 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  11  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:45.144 2009  to  Mon Sep  7 03:55:45.144 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  12  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:55.787 2009  to  Mon Sep  7 03:55:55.787 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  13  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:06.448 2009  to  Mon Sep  7 03:56:06.448 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:17.030 2009  to  Mon Sep  7 03:56:17.030 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:27.716 2009  to  Mon Sep  7 03:56:27.716 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:38.452 2009  to  Mon Sep  7 03:56:38.452 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:49.160 2009  to  Mon Sep  7 03:56:49.160 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  18  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:59.789 2009  to  Mon Sep  7 03:56:59.789 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  19  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:57:10.489 2009  to  Mon Sep  7 03:57:10.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    3.68   23.70   21.64   29.22    85.7 %          7          3          1          3
                                                                       0.21   21.86   21.64   22.04
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    1.25    1.20    0.45    3.11   100.0 %          7          7                      
                                                                       1.25    1.20    0.45    3.11
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .    0.00    4.32    4.32    4.32   100.0 %          1          1                      
                                                                       0.00    4.32    4.32    4.32
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.moveProbeOnGuideStar . . . . . . . . . . . . . . . . .    7.29   11.00    0.97   34.11    93.3 %         15         14          1           
                                                                       7.00   11.72    7.86   34.11
     command.setGuideStar . . . . . . . . . . . . . . . . . . . . .    0.00   10.02   10.02   10.02   100.0 %          1          1                      
                                                                       0.00   10.02   10.02   10.02
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .   11.02   12.09    0.00   41.02    92.9 %         14         14          1           
                                                                      11.00   12.88    0.00   41.02
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    1.39    2.73    0.06    4.04   100.0 %          6          6                      
                                                                       1.39    2.73    0.06    4.04
     command.setSendCentroidsToPCS. . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .    0.00    1.06    1.05    1.06   100.0 %          4          4                      
                                                                       0.00    1.06    1.05    1.06
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          5          5                      
                                                                       0.00    1.05    1.05    1.05
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.06    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.50    0.28    0.05    2.32   100.0 %         23         23                      
                                                                       0.50    0.28    0.05    2.32
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.84    0.66    0.25    2.15   100.0 %          5          5                      
                                                                       0.84    0.66    0.25    2.15
     interface.agw.isPosAccessible. . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         15         15                      
                                                                       0.00    0.05    0.05    0.05
     interface.agw.setFilter. . . . . . . . . . . . . . . . . . . .    3.49    0.98    0.05   13.12   100.0 %         14         14                      
                                                                       3.49    0.98    0.05   13.12
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    4.59    9.61    0.55   20.43    93.3 %         15         14          1           
                                                                       4.00   10.26    7.34   20.43
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.28    1.52    0.42   13.49    99.5 %        631        628          3             interrupted =     3
                                                                       1.29    1.52    0.42   13.49
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    8.22   29.44    5.35   32.45    81.5 %         27         22          5             interrupted =     4
                                                                       0.06   32.39   32.32   32.45
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .   28.49    1.66    0.14  547.44   100.0 %        369        369                        interrupted =     1
                                                                      28.49    1.66    0.14  547.44
     interface.pcs.computeKFPCoordinates. . . . . . . . . . . . . .    0.04    0.18    0.16    0.30   100.0 %         14         14                      
                                                                       0.04    0.18    0.16    0.30
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.43    2.29    1.72    2.98   100.0 %          7          7                      
                                                                       0.43    2.29    1.72    2.98
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .    2.75   12.68    9.35   24.04   100.0 %         22         22                      
                                                                       2.75   12.68    9.35   24.04
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.05    0.21    0.15    0.37   100.0 %         22         22                      
                                                                       0.05    0.21    0.15    0.37

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.externalCentroiding.started. . . . . . . . . . . .     628                      
     sex.started. . . . . . . . . . . . . . . . . . . . . . . . . .     628                      
     sex.complete . . . . . . . . . . . . . . . . . . . . . . . . .     628                      
     guidethread.waiting4sextractor.started . . . . . . . . . . . .     628                      
     guidethread.waiting4sextractor.complete. . . . . . . . . . . .     628                      
     guidethread.externalCentroiding.failed . . . . . . . . . . . .                  2        334
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .       7                      
     guidethread.internalCentroiding.started. . . . . . . . . . . .     334                      
     guidethread.internalCentroiding.complete . . . . . . . . . . .      83                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .       5                      
     wfsthread.imgAnalysis.started. . . . . . . . . . . . . . . . .      22                      
     guidethread.internalCentroiding.failed . . . . . . . . . . . .                           251
 *** guidethread.alert. . . . . . . . . . . . . . . . . . . . . . .                168         89
     wfsthread.imgAnalysis.complete . . . . . . . . . . . . . . . .      22                      
     wfsthread.alert. . . . . . . . . . . . . . . . . . . . . . . .       2                   306
     wfsthread.complete . . . . . . . . . . . . . . . . . . . . . .       5                      
     guidethread.complete . . . . . . . . . . . . . . . . . . . . .       6                      
     guidethread.externalCentroiding.complete . . . . . . . . . . .     292                      

GCS Events of Interest

   1  SHUTDOWN  GCS        command.shutdown                                              Sun Sep  6 19:17:16.868 2009  to  Sun Sep  6 19:17:16.868 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   2  SHUTDOWN  GCS        command.shutdown                                              Sun Sep  6 19:17:17.816 2009  to  Sun Sep  6 19:17:17.816 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   3  STARTUP   GCS        startup                                                       Sun Sep  6 19:17:25.393 2009  to  Sun Sep  6 19:17:25.393 2009   (  0.00) secs
                    

   4  STARTUP   GCS        startup                                                       Sun Sep  6 19:17:25.445 2009  to  Sun Sep  6 19:17:25.445 2009   (  0.00) secs
                    

   5  FAILED    GCS        guidethread.externalCentroiding.failed                        Mon Sep  7 02:54:47.775 2009  to  Mon Sep  7 02:54:47.775 2009   (  0.00) secs
                     sextractor found no star. Trying internal algorithm next
                     star not found with standard algorithm

   6  STARTUP   GCS        startup                                                       Mon Sep  7 04:54:22.846 2009  to  Mon Sep  7 04:54:22.846 2009   (  0.00) secs
                    

   7  STARTUP   GCS        startup                                                       Mon Sep  7 04:54:22.795 2009  to  Mon Sep  7 04:54:22.795 2009   (  0.00) secs
                    

   8  FAILED    GCS        guidethread.externalCentroiding.failed                        Mon Sep  7 05:03:43.844 2009  to  Mon Sep  7 05:03:43.844 2009   (  0.00) secs
                     sextractor found no star. Trying internal algorithm next
                     star not found with standard algorithm

   9  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:15.230 2009  to  Mon Sep  7 05:07:15.230 2009   (  0.00) secs
                     no guide star found, time till warning -0.25 seconds.

  10  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:17.853 2009  to  Mon Sep  7 05:07:17.853 2009   (  0.00) secs
                     no guide star found, time till warning -0.5 seconds.

  11  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:20.324 2009  to  Mon Sep  7 05:07:20.324 2009   (  0.00) secs
                     no guide star found, time till warning -0.75 seconds.

  12  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:22.889 2009  to  Mon Sep  7 05:07:22.889 2009   (  0.00) secs
                     no guide star found, time till warning -1 seconds.

  13  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:25.368 2009  to  Mon Sep  7 05:07:25.368 2009   (  0.00) secs
                     no guide star found, time till warning -1.25 seconds.

  14  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:27.974 2009  to  Mon Sep  7 05:07:27.974 2009   (  0.00) secs
                     no guide star found, time till warning -1.5 seconds.

  15  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:30.599 2009  to  Mon Sep  7 05:07:30.599 2009   (  0.00) secs
                     no guide star found, time till warning -1.75 seconds.

  16  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:33.220 2009  to  Mon Sep  7 05:07:33.220 2009   (  0.00) secs
                     no guide star found, time till warning -2 seconds.

  17  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:35.702 2009  to  Mon Sep  7 05:07:35.702 2009   (  0.00) secs
                     no guide star found, time till warning -2.25 seconds.

  18  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:38.169 2009  to  Mon Sep  7 05:07:38.169 2009   (  0.00) secs
                     no guide star found, time till warning -2.5 seconds.

  19  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:40.753 2009  to  Mon Sep  7 05:07:40.753 2009   (  0.00) secs
                     no guide star found, time till warning -2.75 seconds.

  20  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:43.404 2009  to  Mon Sep  7 05:07:43.404 2009   (  0.00) secs
                     no guide star found, time till warning -3 seconds.

  21  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:45.991 2009  to  Mon Sep  7 05:07:45.991 2009   (  0.00) secs
                     no guide star found, time till warning -3.25 seconds.

  22  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:48.668 2009  to  Mon Sep  7 05:07:48.668 2009   (  0.00) secs
                     no guide star found, time till warning -3.5 seconds.

  23  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:51.341 2009  to  Mon Sep  7 05:07:51.341 2009   (  0.00) secs
                     no guide star found, time till warning -3.75 seconds.

  24  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:53.864 2009  to  Mon Sep  7 05:07:53.864 2009   (  0.00) secs
                     no guide star found, time till warning -4 seconds.

  25  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:56.422 2009  to  Mon Sep  7 05:07:56.422 2009   (  0.00) secs
                     no guide star found, time till warning -4.25 seconds.

  26  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:59.113 2009  to  Mon Sep  7 05:07:59.113 2009   (  0.00) secs
                     no guide star found, time till warning -4.5 seconds.

  27  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:01.630 2009  to  Mon Sep  7 05:08:01.630 2009   (  0.00) secs
                     no guide star found, time till warning -4.75 seconds.

  28  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:04.029 2009  to  Mon Sep  7 05:08:04.029 2009   (  0.00) secs
                     no guide star found, time till warning -5 seconds.

  29  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:06.506 2009  to  Mon Sep  7 05:08:06.506 2009   (  0.00) secs
                     no guide star found, time till warning -5.25 seconds.

  30  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:08.967 2009  to  Mon Sep  7 05:08:08.967 2009   (  0.00) secs
                     no guide star found, time till warning -5.5 seconds.

  31  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:11.624 2009  to  Mon Sep  7 05:08:11.624 2009   (  0.00) secs
                     no guide star found, time till warning -5.75 seconds.

  32  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:14.089 2009  to  Mon Sep  7 05:08:14.089 2009   (  0.00) secs
                     no guide star found, time till warning -6 seconds.

  33  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:16.577 2009  to  Mon Sep  7 05:08:16.577 2009   (  0.00) secs
                     no guide star found, time till warning -6.25 seconds.

  34  FAILED    GCS        command.setGuidestarList                                      Mon Sep  7 05:33:40.712 2009  to  Mon Sep  7 05:33:41.789 2009   (  1.08) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  35  FAILED    GCS        command.moveProbeOnGuideStar                                  Mon Sep  7 05:33:40.768 2009  to  Mon Sep  7 05:33:41.737 2009   (  0.97) secs
                     AGW move failed

  36  FAILED    GCS        interface.agw.setProbePosition                                Mon Sep  7 05:33:41.133 2009  to  Mon Sep  7 05:33:41.686 2009   (  0.55) secs
                     couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGW3: Requested position is Out of Range

  37  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 05:53:35.271 2009  to  Mon Sep  7 05:53:40.622 2009   (  5.35) secs
                     interrupt received while waiting for WFS cam image

  38  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Sep  7 06:02:39.703 2009  to  Mon Sep  7 06:03:08.920 2009   ( 29.22) secs
                     guidewindow
                     guiding was not stable within 6 cycles

  39  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:03:08.321 2009  to  Mon Sep  7 06:03:09.023 2009   (  0.70) secs
                     interrupted received while waiting for a guide image

  40  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:08:15.900 2009  to  Mon Sep  7 06:08:23.110 2009   (  7.21) secs
                     interrupt received while waiting for WFS cam image

  41  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:08:21.490 2009  to  Mon Sep  7 06:08:23.463 2009   (  1.97) secs
                     interrupted received while waiting for a guide image

  42  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:12:57.426 2009  to  Mon Sep  7 06:13:04.893 2009   (  7.47) secs
                     interrupt received while waiting for WFS cam image

  43  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:13:04.064 2009  to  Mon Sep  7 06:13:05.153 2009   (  1.09) secs
                     interrupted received while waiting for a guide image

  44  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:14:36.077 2009  to  Mon Sep  7 06:15:08.522 2009   ( 32.45) secs
                     guide star lost for too long during exposure, not evaluating WFS image

  45  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:20:03.026 2009  to  Mon Sep  7 06:20:32.920 2009   ( 29.89) secs
                     interrupt received while waiting for WFS cam image
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      72                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      48                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Mon Sep  7 03:53:10.441 2009  to  Mon Sep  7 03:53:10.441 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      19                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           104
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      45                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      31                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      31                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      24                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      82                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      14                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .      74                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     467                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     154                      
     MCSPU.HydrostaticBearing.info. . . . . . . . . . . . . . . . .      19                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.ERPlcDevice.readError. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  1           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Sep  7 00:04:23.403 2009  to  Mon Sep  7 00:04:23.403 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 02:57:38.961 2009  to  Mon Sep  7 02:57:38.961 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 02:57:39.036 2009  to  Mon Sep  7 02:57:39.036 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   4  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 02:57:40.101 2009  to  Mon Sep  7 02:57:40.101 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Sep  7 03:28:19.336 2009  to  Mon Sep  7 03:28:19.336 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 1 times

   6  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Sep  7 04:55:28.955 2009  to  Mon Sep  7 04:55:28.955 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 2 times

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 05:53:41.639 2009  to  Mon Sep  7 05:53:41.639 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 05:53:41.639 2009  to  Mon Sep  7 05:53:41.639 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   9  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 05:53:42.647 2009  to  Mon Sep  7 05:53:42.647 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 06:22:07.975 2009  to  Mon Sep  7 06:22:07.975 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 06:22:07.980 2009  to  Mon Sep  7 06:22:07.980 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  12  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon Sep  7 06:22:08.657 2009  to  Mon Sep  7 06:22:08.657 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 1.663765e+00 seconds in the past!

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Mon Sep  7 06:22:08.651 2009  to  Mon Sep  7 06:22:08.651 2009   (  0.00) secs
                     AZ bad poly no. 1: BAD Poly:t0 is -1.657638e+00 seconds in the past!

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Mon Sep  7 06:22:08.652 2009  to  Mon Sep  7 06:22:08.652 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly:t0 is -1.659145e+00 seconds in the past!

  15  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 06:22:08.963 2009  to  Mon Sep  7 06:22:08.963 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       9
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].adsc.moveabs.command . . . . . . . . . . . . . . . . .   10.34   11.07    2.60   43.35    94.4 %         36         34                      
                                                                      10.34   11.07    2.60   43.35
     side[0].terc.adjustcurrfocalstation.command. . . . . . . . . .    3.19    3.66    2.36   14.22    92.9 %         14         13                      
                                                                       3.19    3.66    2.36   14.22
     side[0].terc.getfocalstationcount.command. . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         13         13                      
                                                                       0.00    0.05    0.05    0.05
     side[0].terc.init.command. . . . . . . . . . . . . . . . . . .    0.00  121.55  121.55  121.55    50.0 %          2          1                      
                                                                       0.00  121.55  121.55  121.55
     side[0].terc.movefocalstation.command. . . . . . . . . . . . .   14.84   30.33   17.32   52.64    71.4 %          7          5                      
                                                                      14.84   30.33   17.32   52.64

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].terc.movefocalstation.failed . . . . . . . . . . . . .                  2           
     side[0].adsc.moveabs.failed. . . . . . . . . . . . . . . . . .                  2           
     side[0].terc.adjustcurrfocalstation.failed . . . . . . . . . .                  1           
     side[0].terc . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     side[1].terc . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     side[0].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                  5           
     side[1].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                  5           
     tel.notify_connected . . . . . . . . . . . . . . . . . . . . .      25                      
     tel.notify_disconnected. . . . . . . . . . . . . . . . . . . .      15                      
     side[0].terc.init.failed . . . . . . . . . . . . . . . . . . .                  1           

OSS Events of Interest

   1  FAILED    OSS        side[0].terc.movefocalstation.failed                          Mon Sep  7 00:29:51.879 2009  to  Mon Sep  7 00:29:51.879 2009   (  0.00) secs
                     side[0].terc: [moveFocalStation.moveSelAbs] UMAC is not connected

   2  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Mon Sep  7 00:29:51.828 2009  to  Mon Sep  7 02:44:32.831 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

   3  FAILED    OSS        side[0].adsc.moveabs.failed                                   Mon Sep  7 02:10:06.508 2009  to  Mon Sep  7 02:10:06.508 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

   4  FAILED    OSS        side[0].terc.adjustcurrfocalstation.failed                    Mon Sep  7 02:10:06.518 2009  to  Mon Sep  7 02:10:06.518 2009   (  0.00) secs
                     side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected

   5  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Mon Sep  7 02:10:06.458 2009  to  Mon Sep  7 02:47:16.598 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

   6  SEQERROR  OSS        side[0].terc.adjustcurrfocalstation.command                   Mon Sep  7 02:10:06.468 2009  to  Mon Sep  7 02:47:16.602 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [adjustCurrFocalStation] command.started

   7  STARTUP   OSS        startup                                                       Mon Sep  7 02:11:12.876 2009  to  Mon Sep  7 02:11:12.876 2009   (  0.00) secs
                     The oss was started.

   8  FAILED    OSS        side[0].terc                                                  Mon Sep  7 02:14:22.955 2009  to  Mon Sep  7 02:14:22.955 2009   (  0.00) secs
                     side[0].terc: UMAC is not connected

   9  FAILED    OSS        side[1].terc                                                  Mon Sep  7 02:14:23.456 2009  to  Mon Sep  7 02:14:23.456 2009   (  0.00) secs
                     side[1].terc: UMAC is not connected

  10  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:14:25.965 2009  to  Mon Sep  7 02:14:25.965 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  11  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:14:26.468 2009  to  Mon Sep  7 02:14:26.468 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  12  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:17:45.339 2009  to  Mon Sep  7 02:17:45.339 2009   (  0.00) secs
                     The oss was shut down.

  13  STARTUP   OSS        startup                                                       Mon Sep  7 02:31:53.435 2009  to  Mon Sep  7 02:31:53.435 2009   (  0.00) secs
                     The oss was started.

  14  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:31:57.510 2009  to  Mon Sep  7 02:31:57.510 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  15  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:31:58.011 2009  to  Mon Sep  7 02:31:58.011 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  16  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:33:16.696 2009  to  Mon Sep  7 02:33:16.696 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

  17  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:33:17.723 2009  to  Mon Sep  7 02:33:17.723 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

  18  SEQERROR  OSS        side[0].terc.init.command                                     Mon Sep  7 02:33:23.850 2009  to  Mon Sep  7 02:41:38.888 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [init] command.started

  19  FAILED    OSS        side[0].terc.init.failed                                      Mon Sep  7 02:33:29.888 2009  to  Mon Sep  7 02:33:29.888 2009   (  0.00) secs
                     side[0].terc: [init.waitForInPositionAll.isInPositionAll] Amplifier fault

  20  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:35:58.021 2009  to  Mon Sep  7 02:35:58.021 2009   (  0.00) secs
                     The oss was shut down.

  21  STARTUP   OSS        startup                                                       Mon Sep  7 02:39:02.510 2009  to  Mon Sep  7 02:39:02.510 2009   (  0.00) secs
                     The oss was started.

  22  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:39:06.579 2009  to  Mon Sep  7 02:39:06.579 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  23  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:39:07.104 2009  to  Mon Sep  7 02:39:07.104 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  24  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:40:02.948 2009  to  Mon Sep  7 02:40:02.948 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

  25  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:40:03.812 2009  to  Mon Sep  7 02:40:03.812 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

  26  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Mon Sep  7 02:47:16.598 2009  to  Mon Sep  7 02:53:57.244 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  27  FAILED    OSS        side[0].adsc.moveabs.failed                                   Mon Sep  7 02:47:16.650 2009  to  Mon Sep  7 02:47:16.650 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  28  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:52:24.109 2009  to  Mon Sep  7 02:52:24.109 2009   (  0.00) secs
                     The oss was shut down.

  29  STARTUP   OSS        startup                                                       Mon Sep  7 02:52:49.140 2009  to  Mon Sep  7 02:52:49.140 2009   (  0.00) secs
                     The oss was started.

  30  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:52:53.212 2009  to  Mon Sep  7 02:52:53.212 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  31  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:52:53.714 2009  to  Mon Sep  7 02:52:53.714 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  32  STARTUP   OSS        startup                                                       Mon Sep  7 03:55:31.714 2009  to  Mon Sep  7 03:55:31.714 2009   (  0.00) secs
                     The oss was started.

  33  FAILED    OSS        side[0].swa                                                   Mon Sep  7 03:55:38.873 2009  to  Mon Sep  7 03:55:38.873 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  34  FAILED    OSS        side[1].swa                                                   Mon Sep  7 03:55:39.373 2009  to  Mon Sep  7 03:55:39.373 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  35  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Mon Sep  7 04:58:00.325 2009  to  Mon Sep  7 04:58:04.321 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

  36  FAILED    OSS        side[0].terc.movefocalstation.failed                          Mon Sep  7 04:58:04.373 2009  to  Mon Sep  7 04:58:04.373 2009   (  0.00) secs
                     side[0].terc: [moveFocalStation.moveSelAbs] Umac brake not set.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.02    0.05    0.04    0.21   100.0 %        369        369                      
                                                                       0.02    0.05    0.04    0.21
     guider.command.computeKFPCoordinates . . . . . . . . . . . . .    0.01    0.06    0.05    0.10   100.0 %         14         14                      
                                                                       0.01    0.06    0.05    0.10
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.43    2.18    1.61    2.87   100.0 %          7          7                        largeUpdate =     7
                                                                       0.43    2.18    1.61    2.87
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %         57         57                      
                                                                       0.01    0.05    0.04    0.11
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.05    0.13   100.0 %         60         60                      
                                                                       0.01    0.05    0.05    0.13
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.06    0.05    0.14   100.0 %         14         14                      
                                                                       0.03    0.06    0.05    0.14
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.18    0.62    0.31    1.07   100.0 %         14         14                      
                                                                       0.18    0.62    0.31    1.07
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.04    0.00    0.14   100.0 %         12         12                      
                                                                       0.05    0.08    0.03    0.14

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .       3                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 00:29:51.279 2009  to  Mon Sep  7 00:29:51.392 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   2  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 00:29:51.531 2009  to  Mon Sep  7 00:29:51.531 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   3  FAILED    PCS        telescope.telemetryError                                      Mon Sep  7 02:09:38.895 2009  to  Mon Sep  7 02:09:38.895 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   4  FAILED    PCS        guider.telemetryError                                         Mon Sep  7 02:09:39.873 2009  to  Mon Sep  7 02:09:39.873 2009   (  0.00) secs
                     PCS Guider telemetry error: No telemetry since telemeter registration failed.

   5  STARTUP   PCS        startup                                                       Mon Sep  7 03:55:13.560 2009  to  Mon Sep  7 03:55:13.560 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5Hybrid

   6  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:03:52.501 2009  to  Mon Sep  7 04:03:52.503 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   7  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:03:52.639 2009  to  Mon Sep  7 04:03:52.639 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   8  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:57:59.778 2009  to  Mon Sep  7 04:57:59.893 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   9  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:00.038 2009  to  Mon Sep  7 04:58:00.038 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  10  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:03.786 2009  to  Mon Sep  7 04:58:03.897 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  11  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:04.037 2009  to  Mon Sep  7 04:58:04.037 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  12  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:59:15.333 2009  to  Mon Sep  7 04:59:15.442 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  13  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:59:15.585 2009  to  Mon Sep  7 04:59:15.585 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.40    2.24    2.05    3.06   100.0 %         16         16                      
                                                                       0.40    2.24    2.05    3.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.05    2.05    2.05   100.0 %          4          4                      
                                                                       0.00    2.05    2.05    2.05
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.31    0.31    0.31   100.0 %          1          1                      
                                                                       0.00    0.31    0.31    0.31
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   20.10   23.69    1.25   67.36   100.0 %         18         18                      
                                                                      20.10   23.69    1.25   67.36
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            65
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       4                      
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .     433                      
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      21                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            12
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             1
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      16                      

PMC Events of Interest

   1  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.765 2009  to  Mon Sep  7 02:57:25.765 2009   (  0.00) secs
                     left PMC PMC closing network connection

   2  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.867 2009  to  Mon Sep  7 02:57:25.867 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

   3  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.918 2009  to  Mon Sep  7 02:57:25.918 2009   (  0.00) secs
                     left PMC Async closing network connection

   4  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:26.868 2009  to  Mon Sep  7 02:57:26.868 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   5  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:26.921 2009  to  Mon Sep  7 02:57:26.921 2009   (  0.00) secs
                     left PMC Mount closing network connection

   6  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.023 2009  to  Mon Sep  7 02:57:27.023 2009   (  0.00) secs
                     left PMC Mirror closing network connection

   7  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.125 2009  to  Mon Sep  7 02:57:27.125 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

   8  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.227 2009  to  Mon Sep  7 02:57:27.227 2009   (  0.00) secs
                     left PMC Motor closing network connection

   9  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.329 2009  to  Mon Sep  7 02:57:27.329 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  10  STARTUP   PMC        startup                                                       Mon Sep  7 03:55:49.513 2009  to  Mon Sep  7 03:55:49.513 2009   (  0.00) secs
                     left PMC subsystem started, version 5.1

  11  STARTUP   PMC        startup                                                       Mon Sep  7 03:56:28.448 2009  to  Mon Sep  7 03:56:28.448 2009   (  0.00) secs
                     right PMC subsystem started, version 5.1

  12  FAILED    PMC        VxInterface.close                                             Mon Sep  7 04:01:34.674 2009  to  Mon Sep  7 04:01:34.674 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Mon Sep  7 04:01:34.624 2009  to  Mon Sep  7 04:01:34.624 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.74   12.39    9.06   23.73   100.0 %         22         22                      
                                                                       2.74   12.39    9.06   23.73
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.26    0.25    0.27   100.0 %         14         14                      
                                                                       0.00    0.26    0.25    0.27
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.16    0.12    0.05    0.46   100.0 %         12         12                      
                                                                       0.16    0.12    0.05    0.46
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.74   12.50    9.16   23.84   100.0 %         22         22                      
                                                                       2.74   12.50    9.16   23.84
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.46    3.02    0.14   12.02   100.0 %         22         22                      
                                                                       2.46    3.02    0.14   12.02
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   20.10   23.81    1.36   67.47   100.0 %         18         18                      
                                                                      20.10   23.81    1.36   67.47
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    2.17    2.17    2.17   100.0 %          4          4                      
                                                                       0.00    2.17    2.17    2.17
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.14    0.10    0.06    0.97   100.0 %         82         82                      
                                                                       0.14    0.10    0.06    0.97
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.14    0.17    0.05    0.38    80.0 %          5          4          1           
                                                                       0.14    0.20    0.07    0.38
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.21    0.89    0.74    1.04   100.0 %          2          2                      
                                                                       0.21    0.89    0.74    1.04
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   18.46   49.46   33.74   69.80   100.0 %          3          3                      
                                                                      18.46   49.46   33.74   69.80
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.05   100.0 %         14         14                      
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.05    0.06    0.05    0.29   100.0 %         22         22                      
                                                                       0.05    0.06    0.05    0.29
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.35    8.97    7.76   13.06   100.0 %         22         22                      
                                                                       1.35    8.97    7.76   13.06
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .   10.37   10.57    0.16   43.46    94.4 %         36         34          2           
                                                                      10.35   11.19    2.71   43.46
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         14         14                      
                                                                       0.00    0.05    0.05    0.06
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.17    0.81    0.69    0.93   100.0 %          2          2                      
                                                                       0.17    0.81    0.69    0.93
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.20    0.26    0.07    0.43   100.0 %          4          4                      
                                                                       0.20    0.26    0.07    0.43
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.04    0.06    0.05    0.24   100.0 %         22         22                      
                                                                       0.04    0.06    0.05    0.24
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    3.21    3.51    0.16   14.33    92.9 %         14         13          1           
                                                                       3.19    3.77    2.47   14.33
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.01    0.11    0.11    0.11   100.0 %          2          2                      
                                                                       0.01    0.11    0.11    0.11
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.16    0.21    0.07    0.35   100.0 %          4          4                      
                                                                       0.16    0.21    0.07    0.35

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                251           

PSF Events of Interest

   1  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Mon Sep  7 02:10:06.404 2009  to  Mon Sep  7 02:10:06.562 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

   2  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Sep  7 02:10:06.414 2009  to  Mon Sep  7 02:10:06.572 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation failed for rzColl 0 with argument 0.0000000e+00 because side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected

   3  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Mon Sep  7 02:47:16.543 2009  to  Mon Sep  7 02:47:16.706 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

   4  STARTUP   PSF        startup                                                       Mon Sep  7 04:00:20.473 2009  to  Mon Sep  7 04:00:20.473 2009   (  0.00) secs
                     left PSF subsystem started, version 4.37

   5  STARTUP   PSF        startup                                                       Mon Sep  7 04:00:28.608 2009  to  Mon Sep  7 04:00:28.608 2009   (  0.00) secs
                     right PSF subsystem started, version 4.37

   6  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Mon Sep  7 05:21:45.536 2009  to  Mon Sep  7 05:21:45.589 2009   (  0.05) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   7  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:32.421 2009  to  Mon Sep  7 05:44:32.421 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.6342611e-04 3.7261844e-04 2.5749207e-03 -6.9644928e-02 1.5463448e-01 7.7531338e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:32.674 2009  to  Mon Sep  7 05:44:32.674 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.6342611e-04 3.7261844e-04 2.5749207e-03 -6.9644928e-02 1.5463448e-01 7.7531338e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.244 2009  to  Mon Sep  7 05:44:48.244 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.496 2009  to  Mon Sep  7 05:44:48.496 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.748 2009  to  Mon Sep  7 05:44:48.748 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:08.783 2009  to  Mon Sep  7 05:45:08.783 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:09.036 2009  to  Mon Sep  7 05:45:09.036 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:14.137 2009  to  Mon Sep  7 05:45:14.137 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:14.390 2009  to  Mon Sep  7 05:45:14.390 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:27.253 2009  to  Mon Sep  7 05:45:27.253 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:27.506 2009  to  Mon Sep  7 05:45:27.506 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:36.068 2009  to  Mon Sep  7 05:45:36.068 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6051531e-04 -8.8950992e-04 2.7976036e-03 -2.9766083e-02 1.5555954e-01 8.9614391e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:36.321 2009  to  Mon Sep  7 05:45:36.321 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6051531e-04 -8.8950992e-04 2.7976036e-03 -2.9766083e-02 1.5555954e-01 8.9614391e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:38.997 2009  to  Mon Sep  7 05:45:38.997 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.2782555e-05 9.2178583e-05 3.1268597e-03 -9.2391968e-03 1.2719154e-01 8.7618351e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:39.249 2009  to  Mon Sep  7 05:45:39.249 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.2782555e-05 9.2178583e-05 3.1268597e-03 -9.2391968e-03 1.2719154e-01 8.7618351e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:41.924 2009  to  Mon Sep  7 05:45:41.924 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:42.176 2009  to  Mon Sep  7 05:45:42.176 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:47.275 2009  to  Mon Sep  7 05:45:47.275 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6629696e-05 -5.1577389e-04 3.1327009e-03 -4.4357300e-02 8.8319778e-02 6.6613913e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:47.528 2009  to  Mon Sep  7 05:45:47.528 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6629696e-05 -5.1577389e-04 3.1327009e-03 -4.4357300e-02 8.8319778e-02 6.6613913e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.013 2009  to  Mon Sep  7 05:45:51.013 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.266 2009  to  Mon Sep  7 05:45:51.266 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.519 2009  to  Mon Sep  7 05:45:51.519 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:52.580 2009  to  Mon Sep  7 05:45:52.580 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:52.833 2009  to  Mon Sep  7 05:45:52.833 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:54.500 2009  to  Mon Sep  7 05:45:54.500 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  SHUTDOWN  GCS        command.shutdown                                              Sun Sep  6 19:17:16.868 2009  to  Sun Sep  6 19:17:16.868 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   2  SHUTDOWN  GCS        command.shutdown                                              Sun Sep  6 19:17:17.816 2009  to  Sun Sep  6 19:17:17.816 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   3  STARTUP   GCS        startup                                                       Sun Sep  6 19:17:25.393 2009  to  Sun Sep  6 19:17:25.393 2009   (  0.00) secs
                    

   4  STARTUP   GCS        startup                                                       Sun Sep  6 19:17:25.445 2009  to  Sun Sep  6 19:17:25.445 2009   (  0.00) secs
                    

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Sep  7 00:04:23.403 2009  to  Mon Sep  7 00:04:23.403 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   6  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 00:29:51.279 2009  to  Mon Sep  7 00:29:51.392 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   7  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Sep  7 00:29:51.217 2009  to  Mon Sep  7 00:29:55.291 2009   (  4.07) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: side[0].terc: [moveFocalStation.moveSelAbs] UMAC is not connected
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   8  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 00:29:51.531 2009  to  Mon Sep  7 00:29:51.531 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   9  FAILED    OSS        side[0].terc.movefocalstation.failed                          Mon Sep  7 00:29:51.879 2009  to  Mon Sep  7 00:29:51.879 2009   (  0.00) secs
                     side[0].terc: [moveFocalStation.moveSelAbs] UMAC is not connected

  10  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Mon Sep  7 00:29:51.828 2009  to  Mon Sep  7 02:44:32.831 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

  11  FAILED    IIF        command.preset.(GUIDE)                                        Mon Sep  7 02:09:38.151 2009  to  Mon Sep  7 02:10:32.279 2009   ( 54.13) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset alert for left IRTC mode GUIDE: side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  12  FAILED    PCS        telescope.telemetryError                                      Mon Sep  7 02:09:38.895 2009  to  Mon Sep  7 02:09:38.895 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

  13  FAILED    PCS        guider.telemetryError                                         Mon Sep  7 02:09:39.873 2009  to  Mon Sep  7 02:09:39.873 2009   (  0.00) secs
                     PCS Guider telemetry error: No telemetry since telemeter registration failed.

  14  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Mon Sep  7 02:10:06.404 2009  to  Mon Sep  7 02:10:06.562 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

  15  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Sep  7 02:10:06.414 2009  to  Mon Sep  7 02:10:06.572 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation failed for rzColl 0 with argument 0.0000000e+00 because side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected

  16  FAILED    OSS        side[0].adsc.moveabs.failed                                   Mon Sep  7 02:10:06.508 2009  to  Mon Sep  7 02:10:06.508 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  17  FAILED    OSS        side[0].terc.adjustcurrfocalstation.failed                    Mon Sep  7 02:10:06.518 2009  to  Mon Sep  7 02:10:06.518 2009   (  0.00) secs
                     side[0].terc: [adjustCurrFocalStation.moveMirrorAbs] UMAC is not connected

  18  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Mon Sep  7 02:10:06.458 2009  to  Mon Sep  7 02:47:16.598 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  19  SEQERROR  OSS        side[0].terc.adjustcurrfocalstation.command                   Mon Sep  7 02:10:06.468 2009  to  Mon Sep  7 02:47:16.602 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [adjustCurrFocalStation] command.started

  20  STARTUP   OSS        startup                                                       Mon Sep  7 02:11:12.876 2009  to  Mon Sep  7 02:11:12.876 2009   (  0.00) secs
                     The oss was started.

  21  FAILED    OSS        side[0].terc                                                  Mon Sep  7 02:14:22.955 2009  to  Mon Sep  7 02:14:22.955 2009   (  0.00) secs
                     side[0].terc: UMAC is not connected

  22  FAILED    OSS        side[1].terc                                                  Mon Sep  7 02:14:23.456 2009  to  Mon Sep  7 02:14:23.456 2009   (  0.00) secs
                     side[1].terc: UMAC is not connected

  23  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:14:25.965 2009  to  Mon Sep  7 02:14:25.965 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  24  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:14:26.468 2009  to  Mon Sep  7 02:14:26.468 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  25  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:17:45.339 2009  to  Mon Sep  7 02:17:45.339 2009   (  0.00) secs
                     The oss was shut down.

  26  STARTUP   OSS        startup                                                       Mon Sep  7 02:31:53.435 2009  to  Mon Sep  7 02:31:53.435 2009   (  0.00) secs
                     The oss was started.

  27  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:31:57.510 2009  to  Mon Sep  7 02:31:57.510 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  28  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:31:58.011 2009  to  Mon Sep  7 02:31:58.011 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  29  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:33:16.696 2009  to  Mon Sep  7 02:33:16.696 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

  30  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:33:17.723 2009  to  Mon Sep  7 02:33:17.723 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

  31  SEQERROR  OSS        side[0].terc.init.command                                     Mon Sep  7 02:33:23.850 2009  to  Mon Sep  7 02:41:38.888 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [init] command.started

  32  FAILED    OSS        side[0].terc.init.failed                                      Mon Sep  7 02:33:29.888 2009  to  Mon Sep  7 02:33:29.888 2009   (  0.00) secs
                     side[0].terc: [init.waitForInPositionAll.isInPositionAll] Amplifier fault

  33  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:35:58.021 2009  to  Mon Sep  7 02:35:58.021 2009   (  0.00) secs
                     The oss was shut down.

  34  STARTUP   OSS        startup                                                       Mon Sep  7 02:39:02.510 2009  to  Mon Sep  7 02:39:02.510 2009   (  0.00) secs
                     The oss was started.

  35  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:39:06.579 2009  to  Mon Sep  7 02:39:06.579 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  36  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:39:07.104 2009  to  Mon Sep  7 02:39:07.104 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  37  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:40:02.948 2009  to  Mon Sep  7 02:40:02.948 2009   (  0.00) secs
                     side[0].terc: [startup] command.started

  38  STARTUP   OSS        side[0].terc.startup.command                                  Mon Sep  7 02:40:03.812 2009  to  Mon Sep  7 02:40:03.812 2009   (  0.00) secs
                     side[0].terc: [startup] command.complete

  39  FAILED    IIF        command.preset.(GUIDE)                                        Mon Sep  7 02:47:04.332 2009  to  Mon Sep  7 02:47:29.144 2009   ( 24.81) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  40  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Mon Sep  7 02:47:16.598 2009  to  Mon Sep  7 02:53:57.244 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  41  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Mon Sep  7 02:47:16.543 2009  to  Mon Sep  7 02:47:16.706 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

  42  FAILED    OSS        side[0].adsc.moveabs.failed                                   Mon Sep  7 02:47:16.650 2009  to  Mon Sep  7 02:47:16.650 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  43  SHUTDOWN  OSS        shutdown                                                      Mon Sep  7 02:52:24.109 2009  to  Mon Sep  7 02:52:24.109 2009   (  0.00) secs
                     The oss was shut down.

  44  STARTUP   OSS        startup                                                       Mon Sep  7 02:52:49.140 2009  to  Mon Sep  7 02:52:49.140 2009   (  0.00) secs
                     The oss was started.

  45  FAILED    OSS        side[0].swa                                                   Mon Sep  7 02:52:53.212 2009  to  Mon Sep  7 02:52:53.212 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  46  FAILED    OSS        side[1].swa                                                   Mon Sep  7 02:52:53.714 2009  to  Mon Sep  7 02:52:53.714 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  47  FAILED    GCS        guidethread.externalCentroiding.failed                        Mon Sep  7 02:54:47.775 2009  to  Mon Sep  7 02:54:47.775 2009   (  0.00) secs
                     sextractor found no star. Trying internal algorithm next
                     star not found with standard algorithm

  48  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.765 2009  to  Mon Sep  7 02:57:25.765 2009   (  0.00) secs
                     left PMC PMC closing network connection

  49  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.867 2009  to  Mon Sep  7 02:57:25.867 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

  50  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:25.918 2009  to  Mon Sep  7 02:57:25.918 2009   (  0.00) secs
                     left PMC Async closing network connection

  51  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:26.868 2009  to  Mon Sep  7 02:57:26.868 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  52  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:26.921 2009  to  Mon Sep  7 02:57:26.921 2009   (  0.00) secs
                     left PMC Mount closing network connection

  53  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.023 2009  to  Mon Sep  7 02:57:27.023 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  54  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.125 2009  to  Mon Sep  7 02:57:27.125 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  55  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.227 2009  to  Mon Sep  7 02:57:27.227 2009   (  0.00) secs
                     left PMC Motor closing network connection

  56  FAILED    PMC        VxInterface.close                                             Mon Sep  7 02:57:27.329 2009  to  Mon Sep  7 02:57:27.329 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 02:57:38.961 2009  to  Mon Sep  7 02:57:38.961 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 02:57:39.036 2009  to  Mon Sep  7 02:57:39.036 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 02:57:40.101 2009  to  Mon Sep  7 02:57:40.101 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  60  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Sep  7 03:28:19.336 2009  to  Mon Sep  7 03:28:19.336 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 1 times

  61  STARTUP   LSS        startup                                                       Mon Sep  7 03:53:10.441 2009  to  Mon Sep  7 03:53:10.441 2009   (  0.00) secs
                     The LSS was started.

  62  STARTUP   IIF        startup                                                       Mon Sep  7 03:53:17.393 2009  to  Mon Sep  7 03:53:17.393 2009   (  0.00) secs
                     IIF subsystem started, version 6.11

  63  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:09.005 2009  to  Mon Sep  7 03:54:09.005 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  64  FAILED    ECS        weatherStation.noWeatherData                                  Mon Sep  7 03:54:19.537 2009  to  Mon Sep  7 03:54:19.537 2009   (  0.00) secs
                     Stale or no data being received from SMT.

  65  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:19.819 2009  to  Mon Sep  7 03:54:19.819 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  66  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:30.397 2009  to  Mon Sep  7 03:54:30.397 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  67  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:41.277 2009  to  Mon Sep  7 03:54:41.277 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  68  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:54:51.688 2009  to  Mon Sep  7 03:54:51.688 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  69  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:02.403 2009  to  Mon Sep  7 03:55:02.403 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  70  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:13.053 2009  to  Mon Sep  7 03:55:13.053 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  71  STARTUP   PCS        startup                                                       Mon Sep  7 03:55:13.560 2009  to  Mon Sep  7 03:55:13.560 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.5Hybrid

  72  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:23.672 2009  to  Mon Sep  7 03:55:23.672 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  73  STARTUP   OSS        startup                                                       Mon Sep  7 03:55:31.714 2009  to  Mon Sep  7 03:55:31.714 2009   (  0.00) secs
                     The oss was started.

  74  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:34.381 2009  to  Mon Sep  7 03:55:34.381 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  75  FAILED    OSS        side[0].swa                                                   Mon Sep  7 03:55:38.873 2009  to  Mon Sep  7 03:55:38.873 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  76  FAILED    OSS        side[1].swa                                                   Mon Sep  7 03:55:39.373 2009  to  Mon Sep  7 03:55:39.373 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  77  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:45.144 2009  to  Mon Sep  7 03:55:45.144 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  78  STARTUP   PMC        startup                                                       Mon Sep  7 03:55:49.513 2009  to  Mon Sep  7 03:55:49.513 2009   (  0.00) secs
                     left PMC subsystem started, version 5.1

  79  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:55:55.787 2009  to  Mon Sep  7 03:55:55.787 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  80  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:06.448 2009  to  Mon Sep  7 03:56:06.448 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  81  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:17.030 2009  to  Mon Sep  7 03:56:17.030 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  82  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:27.716 2009  to  Mon Sep  7 03:56:27.716 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  83  STARTUP   PMC        startup                                                       Mon Sep  7 03:56:28.448 2009  to  Mon Sep  7 03:56:28.448 2009   (  0.00) secs
                     right PMC subsystem started, version 5.1

  84  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:38.452 2009  to  Mon Sep  7 03:56:38.452 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  85  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:49.160 2009  to  Mon Sep  7 03:56:49.160 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  86  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:56:59.789 2009  to  Mon Sep  7 03:56:59.789 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  87  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Sep  7 03:57:10.489 2009  to  Mon Sep  7 03:57:10.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  88  STARTUP   PSF        startup                                                       Mon Sep  7 04:00:20.473 2009  to  Mon Sep  7 04:00:20.473 2009   (  0.00) secs
                     left PSF subsystem started, version 4.37

  89  STARTUP   PSF        startup                                                       Mon Sep  7 04:00:28.608 2009  to  Mon Sep  7 04:00:28.608 2009   (  0.00) secs
                     right PSF subsystem started, version 4.37

  90  FAILED    PMC        VxInterface.close                                             Mon Sep  7 04:01:34.674 2009  to  Mon Sep  7 04:01:34.674 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  91  FAILED    PMC        VxInterface.lengthError                                       Mon Sep  7 04:01:34.624 2009  to  Mon Sep  7 04:01:34.624 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  92  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:03:52.501 2009  to  Mon Sep  7 04:03:52.503 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  93  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:03:52.639 2009  to  Mon Sep  7 04:03:52.639 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  94  STARTUP   GCS        startup                                                       Mon Sep  7 04:54:22.846 2009  to  Mon Sep  7 04:54:22.846 2009   (  0.00) secs
                    

  95  STARTUP   GCS        startup                                                       Mon Sep  7 04:54:22.795 2009  to  Mon Sep  7 04:54:22.795 2009   (  0.00) secs
                    

  96  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Sep  7 04:55:28.955 2009  to  Mon Sep  7 04:55:28.955 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 2 times

  97  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:57:59.704 2009  to  Mon Sep  7 04:58:03.726 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at bentGregorianFront focus

  98  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:57:59.778 2009  to  Mon Sep  7 04:57:59.893 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  99  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:00.038 2009  to  Mon Sep  7 04:58:00.038 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 100  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Mon Sep  7 04:58:00.325 2009  to  Mon Sep  7 04:58:04.321 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

 101  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:03.786 2009  to  Mon Sep  7 04:58:03.897 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 102  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:58:03.726 2009  to  Mon Sep  7 04:58:07.696 2009   (  3.97) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: side[0].terc: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

 103  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:58:04.037 2009  to  Mon Sep  7 04:58:04.037 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 104  FAILED    OSS        side[0].terc.movefocalstation.failed                          Mon Sep  7 04:58:04.373 2009  to  Mon Sep  7 04:58:04.373 2009   (  0.00) secs
                     side[0].terc: [moveFocalStation.moveSelAbs] Umac brake not set.

 105  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Sep  7 04:58:21.820 2009  to  Mon Sep  7 04:58:21.820 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left IRTC at bentGregorianFront focus

 106  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:59:15.333 2009  to  Mon Sep  7 04:59:15.442 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 107  SEQERROR  PCS        telescope.command.stopTracking                                Mon Sep  7 04:59:15.585 2009  to  Mon Sep  7 04:59:15.585 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 108  FAILED    GCS        guidethread.externalCentroiding.failed                        Mon Sep  7 05:03:43.844 2009  to  Mon Sep  7 05:03:43.844 2009   (  0.00) secs
                     sextractor found no star. Trying internal algorithm next
                     star not found with standard algorithm

 109  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:15.230 2009  to  Mon Sep  7 05:07:15.230 2009   (  0.00) secs
                     no guide star found, time till warning -0.25 seconds.

 110  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:17.853 2009  to  Mon Sep  7 05:07:17.853 2009   (  0.00) secs
                     no guide star found, time till warning -0.5 seconds.

 111  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:20.324 2009  to  Mon Sep  7 05:07:20.324 2009   (  0.00) secs
                     no guide star found, time till warning -0.75 seconds.

 112  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:22.889 2009  to  Mon Sep  7 05:07:22.889 2009   (  0.00) secs
                     no guide star found, time till warning -1 seconds.

 113  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:25.368 2009  to  Mon Sep  7 05:07:25.368 2009   (  0.00) secs
                     no guide star found, time till warning -1.25 seconds.

 114  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:27.974 2009  to  Mon Sep  7 05:07:27.974 2009   (  0.00) secs
                     no guide star found, time till warning -1.5 seconds.

 115  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:30.599 2009  to  Mon Sep  7 05:07:30.599 2009   (  0.00) secs
                     no guide star found, time till warning -1.75 seconds.

 116  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:33.220 2009  to  Mon Sep  7 05:07:33.220 2009   (  0.00) secs
                     no guide star found, time till warning -2 seconds.

 117  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:35.702 2009  to  Mon Sep  7 05:07:35.702 2009   (  0.00) secs
                     no guide star found, time till warning -2.25 seconds.

 118  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:38.169 2009  to  Mon Sep  7 05:07:38.169 2009   (  0.00) secs
                     no guide star found, time till warning -2.5 seconds.

 119  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:40.753 2009  to  Mon Sep  7 05:07:40.753 2009   (  0.00) secs
                     no guide star found, time till warning -2.75 seconds.

 120  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:43.404 2009  to  Mon Sep  7 05:07:43.404 2009   (  0.00) secs
                     no guide star found, time till warning -3 seconds.

 121  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:45.991 2009  to  Mon Sep  7 05:07:45.991 2009   (  0.00) secs
                     no guide star found, time till warning -3.25 seconds.

 122  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:48.668 2009  to  Mon Sep  7 05:07:48.668 2009   (  0.00) secs
                     no guide star found, time till warning -3.5 seconds.

 123  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:51.341 2009  to  Mon Sep  7 05:07:51.341 2009   (  0.00) secs
                     no guide star found, time till warning -3.75 seconds.

 124  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:53.864 2009  to  Mon Sep  7 05:07:53.864 2009   (  0.00) secs
                     no guide star found, time till warning -4 seconds.

 125  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:56.422 2009  to  Mon Sep  7 05:07:56.422 2009   (  0.00) secs
                     no guide star found, time till warning -4.25 seconds.

 126  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:07:59.113 2009  to  Mon Sep  7 05:07:59.113 2009   (  0.00) secs
                     no guide star found, time till warning -4.5 seconds.

 127  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:01.630 2009  to  Mon Sep  7 05:08:01.630 2009   (  0.00) secs
                     no guide star found, time till warning -4.75 seconds.

 128  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:04.029 2009  to  Mon Sep  7 05:08:04.029 2009   (  0.00) secs
                     no guide star found, time till warning -5 seconds.

 129  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:06.506 2009  to  Mon Sep  7 05:08:06.506 2009   (  0.00) secs
                     no guide star found, time till warning -5.25 seconds.

 130  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:08.967 2009  to  Mon Sep  7 05:08:08.967 2009   (  0.00) secs
                     no guide star found, time till warning -5.5 seconds.

 131  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:11.624 2009  to  Mon Sep  7 05:08:11.624 2009   (  0.00) secs
                     no guide star found, time till warning -5.75 seconds.

 132  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:14.089 2009  to  Mon Sep  7 05:08:14.089 2009   (  0.00) secs
                     no guide star found, time till warning -6 seconds.

 133  FAILED    GCS        guidethread.alert                                             Mon Sep  7 05:08:16.577 2009  to  Mon Sep  7 05:08:16.577 2009   (  0.00) secs
                     no guide star found, time till warning -6.25 seconds.

 134  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Mon Sep  7 05:21:45.536 2009  to  Mon Sep  7 05:21:45.589 2009   (  0.05) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 135  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon Sep  7 05:33:39.222 2009  to  Mon Sep  7 05:33:42.148 2009   (  2.93) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGw command status: AGW3: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGw command status: AGW3: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.860029, -4.05317, 35.2853 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 136  FAILED    GCS        command.setGuidestarList                                      Mon Sep  7 05:33:40.712 2009  to  Mon Sep  7 05:33:41.789 2009   (  1.08) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 137  FAILED    GCS        command.moveProbeOnGuideStar                                  Mon Sep  7 05:33:40.768 2009  to  Mon Sep  7 05:33:41.737 2009   (  0.97) secs
                     AGW move failed

 138  FAILED    GCS        interface.agw.setProbePosition                                Mon Sep  7 05:33:41.133 2009  to  Mon Sep  7 05:33:41.686 2009   (  0.55) secs
                     couldn''t move probe to position (SFP) 0.860029, -4.05317, focus: 35.2853 :AGW3: Requested position is Out of Range

 139  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:32.421 2009  to  Mon Sep  7 05:44:32.421 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.6342611e-04 3.7261844e-04 2.5749207e-03 -6.9644928e-02 1.5463448e-01 7.7531338e-02

 140  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:32.674 2009  to  Mon Sep  7 05:44:32.674 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.6342611e-04 3.7261844e-04 2.5749207e-03 -6.9644928e-02 1.5463448e-01 7.7531338e-02

 141  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.244 2009  to  Mon Sep  7 05:44:48.244 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

 142  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.496 2009  to  Mon Sep  7 05:44:48.496 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

 143  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:44:48.748 2009  to  Mon Sep  7 05:44:48.748 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.1920929e-04 -2.2146106e-04 2.7511120e-03 -1.4915466e-02 1.5000534e-01 6.6333294e-02

 144  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:08.783 2009  to  Mon Sep  7 05:45:08.783 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 145  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:09.036 2009  to  Mon Sep  7 05:45:09.036 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 146  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:14.137 2009  to  Mon Sep  7 05:45:14.137 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 147  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:14.390 2009  to  Mon Sep  7 05:45:14.390 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 148  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:27.253 2009  to  Mon Sep  7 05:45:27.253 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

 149  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:27.506 2009  to  Mon Sep  7 05:45:27.506 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

 150  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:36.068 2009  to  Mon Sep  7 05:45:36.068 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6051531e-04 -8.8950992e-04 2.7976036e-03 -2.9766083e-02 1.5555954e-01 8.9614391e-02

 151  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:36.321 2009  to  Mon Sep  7 05:45:36.321 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6051531e-04 -8.8950992e-04 2.7976036e-03 -2.9766083e-02 1.5555954e-01 8.9614391e-02

 152  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:38.997 2009  to  Mon Sep  7 05:45:38.997 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.2782555e-05 9.2178583e-05 3.1268597e-03 -9.2391968e-03 1.2719154e-01 8.7618351e-02

 153  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:39.249 2009  to  Mon Sep  7 05:45:39.249 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.2782555e-05 9.2178583e-05 3.1268597e-03 -9.2391968e-03 1.2719154e-01 8.7618351e-02

 154  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:41.924 2009  to  Mon Sep  7 05:45:41.924 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 155  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:42.176 2009  to  Mon Sep  7 05:45:42.176 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 156  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:47.275 2009  to  Mon Sep  7 05:45:47.275 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6629696e-05 -5.1577389e-04 3.1327009e-03 -4.4357300e-02 8.8319778e-02 6.6613913e-02

 157  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:47.528 2009  to  Mon Sep  7 05:45:47.528 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6629696e-05 -5.1577389e-04 3.1327009e-03 -4.4357300e-02 8.8319778e-02 6.6613913e-02

 158  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.013 2009  to  Mon Sep  7 05:45:51.013 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 159  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.266 2009  to  Mon Sep  7 05:45:51.266 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 160  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:51.519 2009  to  Mon Sep  7 05:45:51.519 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 161  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:52.580 2009  to  Mon Sep  7 05:45:52.580 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

 162  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:52.833 2009  to  Mon Sep  7 05:45:52.833 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.2672625e-04 -8.7973475e-04 3.1778812e-03 -3.0300140e-02 1.2091064e-01 8.9965343e-02

 163  FAILED    PSF        primaryMirror.positionError                                   Mon Sep  7 05:45:54.500 2009  to  Mon Sep  7 05:45:54.500 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0312281e-04 -8.0356002e-04 3.1358004e-03 -6.0653687e-03 7.6538086e-02 6.6432476e-02

 164  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 05:53:35.271 2009  to  Mon Sep  7 05:53:40.622 2009   (  5.35) secs
                     interrupt received while waiting for WFS cam image

 165  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 05:53:41.639 2009  to  Mon Sep  7 05:53:41.639 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 166  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 05:53:41.639 2009  to  Mon Sep  7 05:53:41.639 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 167  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 05:53:42.647 2009  to  Mon Sep  7 05:53:42.647 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 168  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Sep  7 06:01:52.339 2009  to  Mon Sep  7 06:03:09.439 2009   ( 77.10) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 364
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 169  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Sep  7 06:02:39.703 2009  to  Mon Sep  7 06:03:08.920 2009   ( 29.22) secs
                     guidewindow
                     guiding was not stable within 6 cycles

 170  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:03:08.321 2009  to  Mon Sep  7 06:03:09.023 2009   (  0.70) secs
                     interrupted received while waiting for a guide image

 171  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:08:15.900 2009  to  Mon Sep  7 06:08:23.110 2009   (  7.21) secs
                     interrupt received while waiting for WFS cam image

 172  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:08:21.490 2009  to  Mon Sep  7 06:08:23.463 2009   (  1.97) secs
                     interrupted received while waiting for a guide image

 173  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:12:57.426 2009  to  Mon Sep  7 06:13:04.893 2009   (  7.47) secs
                     interrupt received while waiting for WFS cam image

 174  FAILED    GCS        interface.azcam.guider.readout                                Mon Sep  7 06:13:04.064 2009  to  Mon Sep  7 06:13:05.153 2009   (  1.09) secs
                     interrupted received while waiting for a guide image

 175  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:14:36.077 2009  to  Mon Sep  7 06:15:08.522 2009   ( 32.45) secs
                     guide star lost for too long during exposure, not evaluating WFS image

 176  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon Sep  7 06:20:03.026 2009  to  Mon Sep  7 06:20:32.920 2009   ( 29.89) secs
                     interrupt received while waiting for WFS cam image

 177  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 06:22:07.975 2009  to  Mon Sep  7 06:22:07.975 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 178  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Sep  7 06:22:07.980 2009  to  Mon Sep  7 06:22:07.980 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 179  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon Sep  7 06:22:08.657 2009  to  Mon Sep  7 06:22:08.657 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 1.663765e+00 seconds in the past!

 180  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Mon Sep  7 06:22:08.651 2009  to  Mon Sep  7 06:22:08.651 2009   (  0.00) secs
                     AZ bad poly no. 1: BAD Poly:t0 is -1.657638e+00 seconds in the past!

 181  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Mon Sep  7 06:22:08.652 2009  to  Mon Sep  7 06:22:08.652 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly:t0 is -1.659145e+00 seconds in the past!

 182  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Sep  7 06:22:08.963 2009  to  Mon Sep  7 06:22:08.963 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

**********************************************************
    Reporting period ending:   Mon Sep  7 06:28:58.116 2009
********************************************************************************************************