             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .  332.42  179.97    0.00  720.96    25.0 %          8          2          6           
                                                                       0.15    0.45    0.34    0.56

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:45.622 2009  to  Tue Sep  1 02:27:52.717 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LBC at prime focus

   2  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:45.624 2009  to  Tue Sep  1 02:27:52.719 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:52.717 2009  to  Tue Sep  1 02:27:53.703 2009   (  0.99) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LBC at prime focus

   4  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:52.719 2009  to  Tue Sep  1 02:27:53.481 2009   (  0.76) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:22:32.007 2009  to  Tue Sep  1 05:34:32.962 2009   (720.96) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:22:32.009 2009  to  Tue Sep  1 05:34:28.146 2009   (716.14) secs
                     IIF TCS authorize command started for right IRTC at bentGregorianFront focus
                     IIF TCS authorize alert for right IRTC at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for right IRTC at bentGregorianFront focus

   7  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:34:28.147 2009  to  Tue Sep  1 05:34:28.147 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

   8  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:34:33.331 2009  to  Tue Sep  1 05:34:33.331 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.getMultiDDEntry. . . . . . . . . . . . . . . . . . . .                                   100.0 %                                4           
                                                                                                   
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.05    0.22    0.20    0.38   100.0 %         27         27                      
                                                                       0.05    0.22    0.20    0.38
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    1.98    3.76    1.69    8.70   100.0 %         27         27                      
                                                                       1.98    3.76    1.69    8.70
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.75    3.85    2.76    4.83   100.0 %          5          5                        presetInactive =    10
                                                                       0.75    3.85    2.76    4.83
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.34    3.07    2.55    3.46   100.0 %          5          5                      
                                                                       0.34    3.07    2.55    3.46
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .  117.88   51.22    1.25  541.05    68.2 %         22         15          7           
                                                                      50.76   31.69    6.61  158.21
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   18.98    8.79    1.05   75.19   100.0 %         20         20                      
                                                                      18.98    8.79    1.05   75.19
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   22.56   10.81    2.06   71.15   100.0 %         15         15                      
                                                                      22.56   10.81    2.06   71.15

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             9

IIF Events of Interest

   1  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 21:57:44.575 2009  to  Mon Aug 31 21:57:44.575 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

   2  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 21:58:03.306 2009  to  Mon Aug 31 21:58:03.306 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

   3  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 22:01:55.894 2009  to  Mon Aug 31 22:01:55.894 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

   4  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 23:01:31.197 2009  to  Mon Aug 31 23:01:31.197 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

   5  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:04:12.652 2009  to  Tue Sep  1 03:05:24.760 2009   ( 72.11) secs
                     IIF GetTrajectory command started for both LBC, start time 5.507512793981482e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

   6  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:05:51.680 2009  to  Tue Sep  1 03:06:01.080 2009   (  9.40) secs
                     IIF GetTrajectory command started for both LBC, start time 5.507512908564815e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

   7  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:06:21.860 2009  to  Tue Sep  1 03:06:23.114 2009   (  1.25) secs
                     IIF Preset command started for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

   8  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:24:22.506 2009  to  Tue Sep  1 05:24:24.294 2009   (  1.79) secs
                     IIF Preset command started for left IRTC mode TRACK from IIF
                     IIF Preset alert for left IRTC mode TRACK: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode TRACK from IIF

   9  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:25:27.265 2009  to  Tue Sep  1 05:34:28.320 2009   (541.05) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset alert for left IRTC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode TRACK from IIF

  10  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:42:52.340 2009  to  Tue Sep  1 05:43:06.117 2009   ( 13.78) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode TRACK from IIF

  11  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:52:51.598 2009  to  Tue Sep  1 05:53:03.572 2009   ( 11.97) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3576                      
                                                                                                   
     instrumentCooling.command.setDeadBandTemperature . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7153                      
                                                                                                   
     instrumentCooling.command.setValvePosition . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     instrumentCooling.command.setValveState. . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      36                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .    4.22    6.76    4.32   15.15   100.0 %          6          6                      
                                                                       4.22    6.76    4.32   15.15
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    3.36    2.38    0.00    4.75   100.0 %          2          2                      
                                                                       3.36    2.38    0.00    4.75
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         31         31                      
                                                                       0.00    0.05    0.05    0.05

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      44                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      32                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      57                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      77                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           194
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 12           
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      16                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      43                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     118                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      42                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      23                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            21
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            13
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      63                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       6                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 24           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      35                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      14                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      43                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      51                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.error . . . . . . . . . . . . . . . .                 20           
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     117                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      67                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .       7                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .      21                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:30:27.834 2009  to  Mon Aug 31 20:30:27.834 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:30:27.839 2009  to  Mon Aug 31 20:30:27.839 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:30:27.945 2009  to  Mon Aug 31 20:30:27.945 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:31:27.057 2009  to  Mon Aug 31 20:31:27.057 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:31:27.062 2009  to  Mon Aug 31 20:31:27.062 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:31:27.153 2009  to  Mon Aug 31 20:31:27.153 2009   (  0.00) secs
                     drive cabinet has turned on.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.159 2009  to  Mon Aug 31 20:31:28.159 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.160 2009  to  Mon Aug 31 20:31:28.160 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.160 2009  to  Mon Aug 31 20:31:28.160 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.161 2009  to  Mon Aug 31 20:31:28.161 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.162 2009  to  Mon Aug 31 20:31:28.162 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.163 2009  to  Mon Aug 31 20:31:28.163 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.163 2009  to  Mon Aug 31 20:31:28.163 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.164 2009  to  Mon Aug 31 20:31:28.164 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Mon Aug 31 20:33:09.179 2009  to  Mon Aug 31 20:33:09.179 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:54:24.588 2009  to  Mon Aug 31 20:54:24.588 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:54:24.603 2009  to  Mon Aug 31 20:54:24.603 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  18  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:54:24.701 2009  to  Mon Aug 31 20:54:24.701 2009   (  0.00) secs
                     drive cabinet has turned on.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.728 2009  to  Mon Aug 31 20:54:25.728 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.729 2009  to  Mon Aug 31 20:54:25.729 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.730 2009  to  Mon Aug 31 20:54:25.730 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.730 2009  to  Mon Aug 31 20:54:25.730 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.732 2009  to  Mon Aug 31 20:54:25.732 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.732 2009  to  Mon Aug 31 20:54:25.732 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.733 2009  to  Mon Aug 31 20:54:25.733 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.734 2009  to  Mon Aug 31 20:54:25.734 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:13:17.349 2009  to  Tue Sep  1 03:13:17.349 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:13:17.349 2009  to  Tue Sep  1 03:13:17.349 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:29:35.223 2009  to  Tue Sep  1 03:29:35.223 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:29:35.227 2009  to  Tue Sep  1 03:29:35.227 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Sep  1 03:29:35.331 2009  to  Tue Sep  1 03:29:35.331 2009   (  0.00) secs
                     drive cabinet has turned on.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.335 2009  to  Tue Sep  1 03:29:36.335 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.335 2009  to  Tue Sep  1 03:29:36.335 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.336 2009  to  Tue Sep  1 03:29:36.336 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  35  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.336 2009  to  Tue Sep  1 03:29:36.336 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.363 2009  to  Tue Sep  1 03:29:36.363 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  37  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.364 2009  to  Tue Sep  1 03:29:36.364 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.365 2009  to  Tue Sep  1 03:29:36.365 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.365 2009  to  Tue Sep  1 03:29:36.365 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Sep  1 03:30:40.102 2009  to  Tue Sep  1 03:30:40.102 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  41  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Sep  1 03:31:02.871 2009  to  Tue Sep  1 03:31:02.871 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  42  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.614 2009  to  Tue Sep  1 03:32:09.614 2009   (  0.00) secs
                     2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

  43  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.665 2009  to  Tue Sep  1 03:32:09.665 2009   (  0.00) secs
                     This singleton has not been initialized

  44  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.716 2009  to  Tue Sep  1 03:32:09.716 2009   (  0.00) secs
                     This singleton has not been initialized

  45  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.766 2009  to  Tue Sep  1 03:32:09.766 2009   (  0.00) secs
                     This singleton has not been initialized

  46  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.816 2009  to  Tue Sep  1 03:32:09.816 2009   (  0.00) secs
                     This singleton has not been initialized

  47  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.866 2009  to  Tue Sep  1 03:32:09.866 2009   (  0.00) secs
                     This singleton has not been initialized

  48  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.915 2009  to  Tue Sep  1 03:32:09.915 2009   (  0.00) secs
                     This singleton has not been initialized

  49  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.965 2009  to  Tue Sep  1 03:32:09.965 2009   (  0.00) secs
                     This singleton has not been initialized

  50  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.015 2009  to  Tue Sep  1 03:32:10.015 2009   (  0.00) secs
                     This singleton has not been initialized

  51  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.065 2009  to  Tue Sep  1 03:32:10.065 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_left: This singleton has not been initialized

  52  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.115 2009  to  Tue Sep  1 03:32:10.115 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_left: This singleton has not been initialized

  53  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.165 2009  to  Tue Sep  1 03:32:10.165 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_left: This singleton has not been initialized

  54  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.215 2009  to  Tue Sep  1 03:32:10.215 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_left: This singleton has not been initialized

  55  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.265 2009  to  Tue Sep  1 03:32:10.265 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_right: This singleton has not been initialized

  56  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.315 2009  to  Tue Sep  1 03:32:10.315 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_right: This singleton has not been initialized

  57  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.365 2009  to  Tue Sep  1 03:32:10.365 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_right: This singleton has not been initialized

  58  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.415 2009  to  Tue Sep  1 03:32:10.415 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_right: This singleton has not been initialized

  59  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.465 2009  to  Tue Sep  1 03:32:10.465 2009   (  0.00) secs
                     hbs sys params.variables:This singleton has not been initialized

  60  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.515 2009  to  Tue Sep  1 03:32:10.515 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  61  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.565 2009  to  Tue Sep  1 03:32:10.565 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 05:22:33.167 2009  to  Tue Sep  1 05:22:33.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 05:22:33.208 2009  to  Tue Sep  1 05:22:33.208 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].adsc.home.command. . . . . . . . . . . . . . . . . . .    0.02   44.58   44.57   44.60   100.0 %          2          2                      
                                                                       0.02   44.58   44.57   44.60
     side[0].adsc.moveabs.command . . . . . . . . . . . . . . . . .   15.09    8.51    2.34   42.71    70.0 %         10          7                      
                                                                      15.09    8.51    2.34   42.71
     side[0].adsc.setrelref.command . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     side[0].terc.adjustcurrfocalstation.command. . . . . . . . . .    0.31    3.07    2.58    3.36    83.3 %          6          5                      
                                                                       0.31    3.07    2.58    3.36
     side[0].terc.deinit.command. . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     side[0].terc.getfocalstationcount.command. . . . . . . . . . .    0.04    0.08    0.05    0.12   100.0 %          6          6                      
                                                                       0.04    0.08    0.05    0.12
     side[0].terc.movefocalstation.command. . . . . . . . . . . . .    0.30   22.11   21.90   22.32    40.0 %          5          2                      
                                                                       0.30   22.11   21.90   22.32
     side[1].terc.movefocalstation.command. . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                 10           
     side[1].swa. . . . . . . . . . . . . . . . . . . . . . . . . .                 10           
     side[0].adsc.moveabs.failed. . . . . . . . . . . . . . . . . .                  3           
     inittel.store_client_error . . . . . . . . . . . . . . . . . .                  3           

OSS Events of Interest

   1  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:30:29.851 2009  to  Mon Aug 31 20:30:29.851 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

   2  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:30:29.856 2009  to  Mon Aug 31 20:30:29.856 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

   3  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:30:45.662 2009  to  Mon Aug 31 20:30:45.662 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

   4  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:30:45.671 2009  to  Mon Aug 31 20:30:45.671 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

   5  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:31:30.788 2009  to  Mon Aug 31 20:31:30.788 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

   6  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:31:30.793 2009  to  Mon Aug 31 20:31:30.793 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

   7  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:33:24.524 2009  to  Mon Aug 31 20:33:24.524 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

   8  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:33:24.522 2009  to  Mon Aug 31 20:33:24.522 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

   9  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:54:25.328 2009  to  Mon Aug 31 20:54:25.328 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  10  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:54:25.296 2009  to  Mon Aug 31 20:54:25.296 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  11  SEQERROR  OSS        side[1].terc.movefocalstation.command                         Tue Sep  1 02:27:46.374 2009  to  Tue Sep  1 05:22:32.854 2009   (  0.00) secs
                    Started event but no Complete event
                     side[1].terc: [moveFocalStation] command.started

  12  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 02:27:46.729 2009  to  Tue Sep  1 05:22:33.003 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

  13  FAILED    OSS        side[0].swa                                                   Tue Sep  1 03:28:39.737 2009  to  Tue Sep  1 03:28:39.737 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

  14  FAILED    OSS        side[1].swa                                                   Tue Sep  1 03:28:39.735 2009  to  Tue Sep  1 03:28:39.735 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

  15  FAILED    OSS        side[0].swa                                                   Tue Sep  1 03:29:39.836 2009  to  Tue Sep  1 03:29:39.836 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  16  FAILED    OSS        side[1].swa                                                   Tue Sep  1 03:29:39.823 2009  to  Tue Sep  1 03:29:39.823 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  17  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 05:22:33.003 2009  to  Tue Sep  1 05:31:20.132 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

  18  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:25:46.016 2009  to  Tue Sep  1 05:43:02.851 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  19  SEQERROR  OSS        side[0].terc.adjustcurrfocalstation.command                   Tue Sep  1 05:25:46.018 2009  to  Tue Sep  1 05:43:02.854 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [adjustCurrFocalStation] command.started

  20  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:25:46.066 2009  to  Tue Sep  1 05:25:46.066 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  21  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 05:31:20.132 2009  to  Tue Sep  1 05:47:38.669 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

  22  STARTUP   OSS        startup                                                       Tue Sep  1 05:34:53.207 2009  to  Tue Sep  1 05:34:53.207 2009   (  0.00) secs
                     The oss was started.

  23  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 05:34:56.810 2009  to  Tue Sep  1 05:34:56.810 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

  24  FAILED    OSS        side[0].swa                                                   Tue Sep  1 05:34:57.312 2009  to  Tue Sep  1 05:34:57.312 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  25  FAILED    OSS        side[1].swa                                                   Tue Sep  1 05:34:57.815 2009  to  Tue Sep  1 05:34:57.815 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  26  SHUTDOWN  OSS        shutdown                                                      Tue Sep  1 05:37:36.633 2009  to  Tue Sep  1 05:37:36.633 2009   (  0.00) secs
                     The oss was shut down.

  27  STARTUP   OSS        startup                                                       Tue Sep  1 05:38:30.775 2009  to  Tue Sep  1 05:38:30.775 2009   (  0.00) secs
                     The oss was started.

  28  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 05:38:34.345 2009  to  Tue Sep  1 05:38:34.345 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

  29  FAILED    OSS        side[0].swa                                                   Tue Sep  1 05:38:34.849 2009  to  Tue Sep  1 05:38:34.849 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  30  FAILED    OSS        side[1].swa                                                   Tue Sep  1 05:38:35.350 2009  to  Tue Sep  1 05:38:35.350 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  31  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:43:02.851 2009  to  Tue Sep  1 05:53:00.178 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  32  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:43:02.903 2009  to  Tue Sep  1 05:43:02.903 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  33  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:53:00.178 2009  to  Tue Sep  1 06:06:00.747 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

  34  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:53:00.229 2009  to  Tue Sep  1 05:53:00.229 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

  35  SHUTDOWN  OSS        shutdown                                                      Tue Sep  1 06:01:41.399 2009  to  Tue Sep  1 06:01:41.399 2009   (  0.00) secs
                     The oss was shut down.

  36  STARTUP   OSS        startup                                                       Tue Sep  1 06:02:05.103 2009  to  Tue Sep  1 06:02:05.103 2009   (  0.00) secs
                     The oss was started.

  37  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 06:02:08.671 2009  to  Tue Sep  1 06:02:08.671 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

  38  FAILED    OSS        side[0].swa                                                   Tue Sep  1 06:02:09.173 2009  to  Tue Sep  1 06:02:09.173 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  39  FAILED    OSS        side[1].swa                                                   Tue Sep  1 06:02:09.676 2009  to  Tue Sep  1 06:02:09.676 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     telescope.command.getRotatorTrajectory . . . . . . . . . . . .    0.00    0.09    0.08    0.09   100.0 %         27         27                      
                                                                       0.00    0.09    0.08    0.09
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          8          8                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.reloadAuthorizedPM . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         12         12                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.06    0.05    0.15   100.0 %         22         22                      
                                                                       0.03    0.06    0.05    0.15
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.02    0.06    0.05    0.09   100.0 %          4          4                      
                                                                       0.02    0.06    0.05    0.09
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.24    0.58    0.31    0.87    95.5 %         22         20          1           
                                                                       0.24    0.57    0.31    0.87
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.07   -0.00    0.11    75.0 %          8                     2           
                                                                       0.04    0.08   -0.00    0.10

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  3           
     telemetryError . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           
     weather.telemetryError . . . . . . . . . . . . . . . . . . . .                  2           

PCS Events of Interest

   1  FAILED    PCS        telescope.command.stopTracking                                Tue Sep  1 02:27:52.776 2009  to  Tue Sep  1 02:27:52.883 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Tue Sep  1 02:27:52.884 2009  to  Tue Sep  1 02:27:52.992 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 03:04:13.161 2009  to  Tue Sep  1 03:04:13.161 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   4  SEQERROR  PCS        telescope.command.startTracking                               Tue Sep  1 03:06:22.392 2009  to  Tue Sep  1 04:49:32.433 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

   5  STARTUP   PCS        startup                                                       Tue Sep  1 03:13:25.398 2009  to  Tue Sep  1 03:13:25.398 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 4.1

   6  FAILED    PCS        telemetryError                                                Tue Sep  1 03:13:25.465 2009  to  Tue Sep  1 03:13:25.465 2009   (  0.00) secs
                     PCS telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

   7  FAILED    PCS        guider.telemetryError                                         Tue Sep  1 03:13:25.574 2009  to  Tue Sep  1 03:13:25.574 2009   (  0.00) secs
                     PCS Guider telemetry error: This singleton has not been initialized

   8  FAILED    PCS        weather.telemetryError                                        Tue Sep  1 03:13:25.628 2009  to  Tue Sep  1 03:13:25.628 2009   (  0.00) secs
                     PCS Weather telemetry error: This singleton has not been initialized

   9  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 03:13:25.680 2009  to  Tue Sep  1 03:13:25.680 2009   (  0.00) secs
                     PCS Telescope telemetry error: This singleton has not been initialized

  10  FAILED    PCS        weather.telemetryError                                        Tue Sep  1 03:13:25.736 2009  to  Tue Sep  1 03:13:25.736 2009   (  0.00) secs
                     PCS Weather telemetry error: No telemetry since telemeter registration failed.

  11  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 04:49:32.319 2009  to  Tue Sep  1 04:49:32.319 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

  12  SEQERROR  PCS        telescope.command.stopTracking                                Tue Sep  1 05:22:32.069 2009  to  Tue Sep  1 05:22:32.174 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  13  SEQERROR  PCS        telescope.command.stopTracking                                Tue Sep  1 05:22:32.279 2009  to  Tue Sep  1 05:22:32.279 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  14  FAILED    PCS        telescope.command.startTracking                               Tue Sep  1 05:24:23.264 2009  to  Tue Sep  1 05:24:24.088 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.03    2.06    2.05    2.14   100.0 %         10         10                      
                                                                       0.03    2.06    2.05    2.14
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.05    5.05    5.05     0.0 %          2                     2           
                                                                                                   
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.66    0.66    0.66   100.0 %          1          1                      
                                                                       0.00    0.66    0.66    0.66
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.15   66.15   66.15   100.0 %          1          1                      
                                                                       0.00   66.15   66.15   66.15
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    4.07    4.07    4.07   100.0 %          1          1                      
                                                                       0.00    4.07    4.07    4.07
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   17.57    8.77    1.25   90.39    97.3 %         73         71          2           
                                                                      17.60    8.48    1.25   90.39
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  233.57  233.57  233.57   100.0 %          1          1                      
                                                                       0.00  233.57  233.57  233.57
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.11    0.11    0.11   100.0 %          1          1                      
                                                                       0.00    0.11    0.11    0.11

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            37
 *** voltageMonitor.plus7.failed. . . . . . . . . . . . . . . . . .                 33           
     actuator.setForce.timeout. . . . . . . . . . . . . . . . . . .                  3           
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             2
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             5
 *** actuator.setForce.addressError . . . . . . . . . . . . . . . .                 54           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                918           
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                           249
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  3           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                           227
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                            25
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                 24           
     actuator.getForce.readError. . . . . . . . . . . . . . . . . .                 19           
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       6                      
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 11           
     telemetryError . . . . . . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      21                      
 *** actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                640           
     airPressure.telemetryError . . . . . . . . . . . . . . . . . .                  4           
     motor.telemetryError . . . . . . . . . . . . . . . . . . . . .                  4           
     hardPoint.telemetryError . . . . . . . . . . . . . . . . . . .                  4           
     mirror.telemetryError. . . . . . . . . . . . . . . . . . . . .                  4           
     servoLoop.telemetryError . . . . . . . . . . . . . . . . . . .                  4           
     thermal.telemetryError . . . . . . . . . . . . . . . . . . . .                  4           
     cellStatus.telemetryError. . . . . . . . . . . . . . . . . . .                  4           
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                             2
 *** hardPoint.getData.timeout. . . . . . . . . . . . . . . . . . .                510           
     voltageMonitor.plus15.failed . . . . . . . . . . . . . . . . .                 20           
     voltageMonitor.minus15.failed. . . . . . . . . . . . . . . . .                 20           
     voltageMonitor.plus20.failed . . . . . . . . . . . . . . . . .                 20           
     mirror.cellLoad.exceeded . . . . . . . . . . . . . . . . . . .                          3418
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  2           
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .      10                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             3
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:01:52.490 2009  to  Mon Aug 31 20:01:52.490 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.69 V, requirement is 7.65

   2  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:50.791 2009  to  Mon Aug 31 20:02:50.791 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.83 V, requirement is 7.65

   3  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:52.358 2009  to  Mon Aug 31 20:02:52.358 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

   4  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:55.187 2009  to  Mon Aug 31 20:02:55.187 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.87 V, requirement is 7.65

   5  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:58.509 2009  to  Mon Aug 31 20:02:58.509 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.83 V, requirement is 7.65

   6  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:06.375 2009  to  Mon Aug 31 20:03:06.375 2009   (  0.00) secs
                     right PMC Actuator 101 set force time out

   7  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:07.185 2009  to  Mon Aug 31 20:03:07.185 2009   (  0.00) secs
                     right PMC Actuator 122 set force time out

   8  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:08.498 2009  to  Mon Aug 31 20:03:08.498 2009   (  0.00) secs
                     right PMC Actuator 218 set force time out

   9  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:09.305 2009  to  Mon Aug 31 20:03:09.305 2009   (  0.00) secs
                     right PMC Actuator 223 set force bad return: 164 instead of 9

  10  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.356 2009  to  Mon Aug 31 20:03:09.356 2009   (  0.00) secs
                     right PMC Actuator 304 has been reset

  11  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.406 2009  to  Mon Aug 31 20:03:09.406 2009   (  0.00) secs
                     right PMC Actuator 238 has been reset

  12  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.457 2009  to  Mon Aug 31 20:03:09.457 2009   (  0.00) secs
                     right PMC Actuator 303 has been reset

  13  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.508 2009  to  Mon Aug 31 20:03:09.508 2009   (  0.00) secs
                     right PMC Actuator 302 has been reset

  14  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.559 2009  to  Mon Aug 31 20:03:09.559 2009   (  0.00) secs
                     right PMC Actuator 235 has been reset

  15  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.610 2009  to  Mon Aug 31 20:03:09.610 2009   (  0.00) secs
                     right PMC Actuator 236 has been reset

  16  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.661 2009  to  Mon Aug 31 20:03:09.661 2009   (  0.00) secs
                     right PMC Actuator 240 has been reset

  17  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.713 2009  to  Mon Aug 31 20:03:09.713 2009   (  0.00) secs
                     right PMC Actuator 305 has been reset

  18  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.234 2009  to  Mon Aug 31 20:03:10.234 2009   (  0.00) secs
                     right PMC Actuator 316 has been reset

  19  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.438 2009  to  Mon Aug 31 20:03:10.438 2009   (  0.00) secs
                     right PMC Actuator 312 has been reset

  20  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.643 2009  to  Mon Aug 31 20:03:10.643 2009   (  0.00) secs
                     right PMC Actuator 307 has been reset

  21  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.848 2009  to  Mon Aug 31 20:03:10.848 2009   (  0.00) secs
                     right PMC Actuator 309 has been reset

  22  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.053 2009  to  Mon Aug 31 20:03:11.053 2009   (  0.00) secs
                     right PMC Actuator 306 has been reset

  23  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.257 2009  to  Mon Aug 31 20:03:11.257 2009   (  0.00) secs
                     right PMC Actuator 311 has been reset

  24  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.462 2009  to  Mon Aug 31 20:03:11.462 2009   (  0.00) secs
                     right PMC Actuator 308 has been reset

  25  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.666 2009  to  Mon Aug 31 20:03:11.666 2009   (  0.00) secs
                     right PMC Actuator 317 has been reset

  26  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.123 2009  to  Mon Aug 31 20:03:12.123 2009   (  0.00) secs
                     right PMC Actuator 321 has been reset

  27  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.326 2009  to  Mon Aug 31 20:03:12.326 2009   (  0.00) secs
                     right PMC Actuator 322 has been reset

  28  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.560 2009  to  Mon Aug 31 20:03:12.560 2009   (  0.00) secs
                     right PMC Actuator 323 has been reset

  29  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.765 2009  to  Mon Aug 31 20:03:12.765 2009   (  0.00) secs
                     right PMC Actuator 313 has been reset

  30  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.969 2009  to  Mon Aug 31 20:03:12.969 2009   (  0.00) secs
                     right PMC Actuator 310 has been reset

  31  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.174 2009  to  Mon Aug 31 20:03:13.174 2009   (  0.00) secs
                     right PMC Actuator 315 has been reset

  32  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.378 2009  to  Mon Aug 31 20:03:13.378 2009   (  0.00) secs
                     right PMC Actuator 319 has been reset

  33  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.582 2009  to  Mon Aug 31 20:03:13.582 2009   (  0.00) secs
                     right PMC Actuator 320 has been reset

  34  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.786 2009  to  Mon Aug 31 20:03:13.786 2009   (  0.00) secs
                     right PMC Actuator 335 has been reset

  35  FAILED    PMC        mirror.panic                                                  Mon Aug 31 20:03:27.482 2009  to  Mon Aug 31 20:03:27.482 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  36  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:32.046 2009  to  Mon Aug 31 20:03:32.046 2009   (  0.00) secs
                     right PMC Actuator 329 set force bad return: 237 instead of 15

  37  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 20:03:32.551 2009  to  Mon Aug 31 20:03:32.551 2009   (  0.00) secs
                     right PMC Actuator 418 set force read error: -3

  38  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:34.371 2009  to  Mon Aug 31 20:03:34.371 2009   (  0.00) secs
                     right PMC Actuator 432 set force bad return: 128 instead of 18

  39  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:03:45.718 2009  to  Mon Aug 31 20:03:45.718 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.74 V, requirement is 7.65

  40  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:27.685 2009  to  Mon Aug 31 20:08:27.685 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.92 V, requirement is 7.65

  41  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:30.011 2009  to  Mon Aug 31 20:08:30.011 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

  42  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:31.072 2009  to  Mon Aug 31 20:08:31.072 2009   (  0.00) secs
                     right PMC 7 volt failure: 8.01 V, requirement is 7.65

  43  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:09:05.916 2009  to  Mon Aug 31 20:09:05.916 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.74 V, requirement is 7.65

  44  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:09:06.473 2009  to  Mon Aug 31 20:09:06.473 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

  45  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 20:12:19.733 2009  to  Mon Aug 31 20:12:19.733 2009   (  0.00) secs
                     right PMC Actuator 241 get force read error: -3

  46  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:19.784 2009  to  Mon Aug 31 20:12:19.784 2009   (  0.00) secs
                     right PMC Actuator 103 set force bad return: 196 instead of 1

  47  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 20:12:20.087 2009  to  Mon Aug 31 20:12:20.087 2009   (  0.00) secs
                     right PMC Actuator 238 get force read error: -3

  48  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:20.137 2009  to  Mon Aug 31 20:12:20.137 2009   (  0.00) secs
                     right PMC Actuator 102 set force bad return: 254 instead of 1

  49  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:22.535 2009  to  Mon Aug 31 20:12:22.535 2009   (  0.00) secs
                     right PMC Actuator 106 set force bad return: 253 instead of 1

  50  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:23.587 2009  to  Mon Aug 31 21:00:23.587 2009   (  0.00) secs
                     right PMC Actuator 237 get force read error: -3

  51  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:23.639 2009  to  Mon Aug 31 21:00:23.639 2009   (  0.00) secs
                     right PMC Actuator 105 set force bad return: 219 instead of 1

  52  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:24.194 2009  to  Mon Aug 31 21:00:24.194 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

  53  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:24.245 2009  to  Mon Aug 31 21:00:24.245 2009   (  0.00) secs
                     right PMC Actuator 102 set force bad return: 248 instead of 1

  54  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:26.931 2009  to  Mon Aug 31 21:00:26.931 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

  55  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:00:27.033 2009  to  Mon Aug 31 21:00:27.033 2009   (  0.00) secs
                     right PMC Actuator 109 set force read error: -3

  56  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:27.337 2009  to  Mon Aug 31 21:00:27.337 2009   (  0.00) secs
                     right PMC Actuator 138 set force bad return: 2 instead of 5

  57  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.357 2009  to  Mon Aug 31 21:10:15.357 2009   (  0.00) secs
                     right PMC PMC closing network connection

  58  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.408 2009  to  Mon Aug 31 21:10:15.408 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

  59  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.459 2009  to  Mon Aug 31 21:10:15.459 2009   (  0.00) secs
                     right PMC Async closing network connection

  60  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.510 2009  to  Mon Aug 31 21:10:15.510 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  61  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.561 2009  to  Mon Aug 31 21:10:15.561 2009   (  0.00) secs
                     right PMC Mount closing network connection

  62  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.612 2009  to  Mon Aug 31 21:10:15.612 2009   (  0.00) secs
                     right PMC Mirror closing network connection

  63  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.663 2009  to  Mon Aug 31 21:10:15.663 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  64  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.714 2009  to  Mon Aug 31 21:10:15.714 2009   (  0.00) secs
                     right PMC Motor closing network connection

  65  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.765 2009  to  Mon Aug 31 21:10:15.765 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

  66  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.817 2009  to  Mon Aug 31 21:10:15.817 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  67  SHUTDOWN  PMC        shutdown                                                      Mon Aug 31 21:10:15.868 2009  to  Mon Aug 31 21:10:15.868 2009   (  0.00) secs
                     right PMC subsystem shut down

  68  FAILED    PMC        telemetryError                                                Mon Aug 31 21:10:21.151 2009  to  Mon Aug 31 21:10:21.151 2009   (  0.00) secs
                     right PMC telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

  69  STARTUP   PMC        startup                                                       Mon Aug 31 21:10:21.098 2009  to  Mon Aug 31 21:10:21.098 2009   (  0.00) secs
                     right PMC subsystem started, version 5.0

  70  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:21.994 2009  to  Mon Aug 31 21:10:21.994 2009   (  0.00) secs
                     right PMC Actuator 101 telemetry error: This singleton has not been initialized

  71  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.045 2009  to  Mon Aug 31 21:10:22.045 2009   (  0.00) secs
                     right PMC Actuator 102 telemetry error: This singleton has not been initialized

  72  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.096 2009  to  Mon Aug 31 21:10:22.096 2009   (  0.00) secs
                     right PMC Actuator 103 telemetry error: This singleton has not been initialized

  73  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.147 2009  to  Mon Aug 31 21:10:22.147 2009   (  0.00) secs
                     right PMC Actuator 104 telemetry error: This singleton has not been initialized

  74  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.198 2009  to  Mon Aug 31 21:10:22.198 2009   (  0.00) secs
                     right PMC Actuator 105 telemetry error: This singleton has not been initialized

  75  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.249 2009  to  Mon Aug 31 21:10:22.249 2009   (  0.00) secs
                     right PMC Actuator 106 telemetry error: This singleton has not been initialized

  76  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.300 2009  to  Mon Aug 31 21:10:22.300 2009   (  0.00) secs
                     right PMC Actuator 107 telemetry error: This singleton has not been initialized

  77  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.351 2009  to  Mon Aug 31 21:10:22.351 2009   (  0.00) secs
                     right PMC Actuator 108 telemetry error: This singleton has not been initialized

  78  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.401 2009  to  Mon Aug 31 21:10:22.401 2009   (  0.00) secs
                     right PMC Actuator 109 telemetry error: This singleton has not been initialized

  79  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.451 2009  to  Mon Aug 31 21:10:22.451 2009   (  0.00) secs
                     right PMC Actuator 110 telemetry error: This singleton has not been initialized

  80  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.502 2009  to  Mon Aug 31 21:10:22.502 2009   (  0.00) secs
                     right PMC Actuator 111 telemetry error: This singleton has not been initialized

  81  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.552 2009  to  Mon Aug 31 21:10:22.552 2009   (  0.00) secs
                     right PMC Actuator 112 telemetry error: This singleton has not been initialized

  82  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.604 2009  to  Mon Aug 31 21:10:22.604 2009   (  0.00) secs
                     right PMC Actuator 113 telemetry error: This singleton has not been initialized

  83  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.654 2009  to  Mon Aug 31 21:10:22.654 2009   (  0.00) secs
                     right PMC Actuator 114 telemetry error: This singleton has not been initialized

  84  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.772 2009  to  Mon Aug 31 21:10:22.772 2009   (  0.00) secs
                     right PMC Actuator 115 telemetry error: This singleton has not been initialized

  85  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.822 2009  to  Mon Aug 31 21:10:22.822 2009   (  0.00) secs
                     right PMC Actuator 116 telemetry error: This singleton has not been initialized

  86  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.872 2009  to  Mon Aug 31 21:10:22.872 2009   (  0.00) secs
                     right PMC Actuator 117 telemetry error: This singleton has not been initialized

  87  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.922 2009  to  Mon Aug 31 21:10:22.922 2009   (  0.00) secs
                     right PMC Actuator 118 telemetry error: This singleton has not been initialized

  88  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.972 2009  to  Mon Aug 31 21:10:22.972 2009   (  0.00) secs
                     right PMC Actuator 119 telemetry error: This singleton has not been initialized

  89  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.023 2009  to  Mon Aug 31 21:10:23.023 2009   (  0.00) secs
                     right PMC Actuator 120 telemetry error: This singleton has not been initialized

  90  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.073 2009  to  Mon Aug 31 21:10:23.073 2009   (  0.00) secs
                     right PMC Actuator 121 telemetry error: This singleton has not been initialized

  91  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.123 2009  to  Mon Aug 31 21:10:23.123 2009   (  0.00) secs
                     right PMC Actuator 122 telemetry error: This singleton has not been initialized

  92  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.173 2009  to  Mon Aug 31 21:10:23.173 2009   (  0.00) secs
                     right PMC Actuator 123 telemetry error: This singleton has not been initialized

  93  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.223 2009  to  Mon Aug 31 21:10:23.223 2009   (  0.00) secs
                     right PMC Actuator 124 telemetry error: This singleton has not been initialized

  94  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.273 2009  to  Mon Aug 31 21:10:23.273 2009   (  0.00) secs
                     right PMC Actuator 125 telemetry error: This singleton has not been initialized

  95  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 21:10:30.312 2009  to  Mon Aug 31 21:10:30.312 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: This singleton has not been initialized

  96  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 21:10:30.412 2009  to  Mon Aug 31 21:10:30.412 2009   (  0.00) secs
                     right PMC Motor telemetry error: This singleton has not been initialized

  97  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 21:10:30.584 2009  to  Mon Aug 31 21:10:30.584 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: This singleton has not been initialized

  98  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 21:10:30.684 2009  to  Mon Aug 31 21:10:30.684 2009   (  0.00) secs
                     right PMC Mirror telemetry error: This singleton has not been initialized

  99  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 21:10:30.834 2009  to  Mon Aug 31 21:10:30.834 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: This singleton has not been initialized

 100  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 21:10:32.091 2009  to  Mon Aug 31 21:10:32.091 2009   (  0.00) secs
                     right PMC Thermal telemetry error: This singleton has not been initialized

 101  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 21:10:32.194 2009  to  Mon Aug 31 21:10:32.194 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: This singleton has not been initialized

 102  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 21:10:33.477 2009  to  Mon Aug 31 21:10:33.477 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: No telemetry since telemeter registration failed.

 103  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 21:10:33.518 2009  to  Mon Aug 31 21:10:33.518 2009   (  0.00) secs
                     right PMC Mirror telemetry error: No telemetry since telemeter registration failed.

 104  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 21:10:33.458 2009  to  Mon Aug 31 21:10:33.458 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 105  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 21:10:33.540 2009  to  Mon Aug 31 21:10:33.540 2009   (  0.00) secs
                     right PMC Motor telemetry error: No telemetry since telemeter registration failed.

 106  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 21:10:33.694 2009  to  Mon Aug 31 21:10:33.694 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: No telemetry since telemeter registration failed.

 107  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 21:10:33.799 2009  to  Mon Aug 31 21:10:33.799 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: No telemetry since telemeter registration failed.

 108  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 21:10:42.381 2009  to  Mon Aug 31 21:10:42.381 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 109  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:48.825 2009  to  Mon Aug 31 21:33:48.825 2009   (  0.00) secs
                     right PMC Actuator 128 set force bad return: 243 instead of 3

 110  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:48.875 2009  to  Mon Aug 31 21:33:48.875 2009   (  0.00) secs
                     right PMC Actuator 119 set force read error: -3

 111  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:49.179 2009  to  Mon Aug 31 21:33:49.179 2009   (  0.00) secs
                     right PMC Actuator 135 set force bad return: 31 instead of 4

 112  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:49.593 2009  to  Mon Aug 31 21:33:49.593 2009   (  0.00) secs
                     right PMC Actuator 134 set force read error: -3

 113  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:52.050 2009  to  Mon Aug 31 21:33:52.050 2009   (  0.00) secs
                     right PMC Actuator 136 set force bad return: 67 instead of 5

 114  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:57.593 2009  to  Mon Aug 31 21:33:57.593 2009   (  0.00) secs
                     right PMC Actuator 219 set force read error: -3

 115  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:57.644 2009  to  Mon Aug 31 21:33:57.644 2009   (  0.00) secs
                     right PMC Actuator 220 set force bad return: 254 instead of 8

 116  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:59.708 2009  to  Mon Aug 31 21:33:59.708 2009   (  0.00) secs
                     right PMC Actuator 107 set force bad return: 243 instead of 1

 117  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:00.011 2009  to  Mon Aug 31 21:34:00.011 2009   (  0.00) secs
                     right PMC Actuator 102 set force read error: -3

 118  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:00.314 2009  to  Mon Aug 31 21:34:00.314 2009   (  0.00) secs
                     right PMC Actuator 111 set force bad return: 244 instead of 2

 119  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:02.822 2009  to  Mon Aug 31 21:34:02.822 2009   (  0.00) secs
                     right PMC Actuator 116 set force bad return: 253 instead of 2

 120  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:11.909 2009  to  Mon Aug 31 21:34:11.909 2009   (  0.00) secs
                     right PMC Actuator 106 set force read error: -3

 121  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:11.960 2009  to  Mon Aug 31 21:34:11.960 2009   (  0.00) secs
                     right PMC Actuator 114 set force bad return: 254 instead of 2

 122  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:12.011 2009  to  Mon Aug 31 21:34:12.011 2009   (  0.00) secs
                     right PMC Actuator 107 set force read error: -3

 123  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:12.062 2009  to  Mon Aug 31 21:34:12.062 2009   (  0.00) secs
                     right PMC Actuator 112 set force bad return: 255 instead of 2

 124  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:34:14.131 2009  to  Mon Aug 31 21:34:14.131 2009   (  0.00) secs
                     right PMC Actuator 140 get force read error: -3

 125  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:14.181 2009  to  Mon Aug 31 21:34:14.181 2009   (  0.00) secs
                     right PMC Actuator 107 set force bad return: 239 instead of 1

 126  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:14.232 2009  to  Mon Aug 31 21:34:14.232 2009   (  0.00) secs
                     right PMC Actuator 103 set force read error: -3

 127  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:17.079 2009  to  Mon Aug 31 21:34:17.079 2009   (  0.00) secs
                     right PMC Actuator 108 set force bad return: 246 instead of 1

 128  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:34.811 2009  to  Mon Aug 31 21:34:34.811 2009   (  0.00) secs
                     right PMC Actuator 333 set force bad return: 96 instead of 16

 129  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:36.930 2009  to  Mon Aug 31 21:34:36.930 2009   (  0.00) secs
                     right PMC Actuator 240 set force bad return: 10 instead of 11

 130  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:37.284 2009  to  Mon Aug 31 21:34:37.284 2009   (  0.00) secs
                     right PMC Actuator 311 set force bad return: 20 instead of 11

 131  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:37.637 2009  to  Mon Aug 31 21:34:37.637 2009   (  0.00) secs
                     right PMC Actuator 307 set force read error: -3

 132  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:39.825 2009  to  Mon Aug 31 21:34:39.825 2009   (  0.00) secs
                     right PMC Actuator 325 set force bad return: 21 instead of 14

 133  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:52.687 2009  to  Mon Aug 31 21:34:52.687 2009   (  0.00) secs
                     right PMC Actuator 329 set force bad return: 237 instead of 15

 134  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:53.497 2009  to  Mon Aug 31 21:34:53.497 2009   (  0.00) secs
                     right PMC Actuator 417 set force read error: -3

 135  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:54.652 2009  to  Mon Aug 31 21:34:54.652 2009   (  0.00) secs
                     right PMC Actuator 425 set force read error: -3

 136  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:35:30.209 2009  to  Mon Aug 31 21:35:30.209 2009   (  0.00) secs
                     right PMC Actuator 428 set force read error: -3

 137  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:35.726 2009  to  Mon Aug 31 21:35:35.726 2009   (  0.00) secs
                     right PMC Actuator 307 get force read error: -3

 138  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:37.796 2009  to  Mon Aug 31 21:35:37.796 2009   (  0.00) secs
                     right PMC Actuator 410 get force read error: -3

 139  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:38.402 2009  to  Mon Aug 31 21:35:38.402 2009   (  0.00) secs
                     right PMC Actuator 435 get force read error: -3

 140  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:01.159 2009  to  Mon Aug 31 21:37:01.159 2009   (  0.00) secs
                     right PMC Actuator 109 set force read error: -3

 141  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:03.440 2009  to  Mon Aug 31 21:37:03.440 2009   (  0.00) secs
                     right PMC Actuator 137 set force read error: -3

 142  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:04.001 2009  to  Mon Aug 31 21:37:04.001 2009   (  0.00) secs
                     right PMC Actuator 231 set force read error: -3

 143  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:12.307 2009  to  Mon Aug 31 21:37:12.307 2009   (  0.00) secs
                     right PMC Actuator 328 set force read error: -3

 144  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:18.287 2009  to  Mon Aug 31 21:37:18.287 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

 145  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:18.337 2009  to  Mon Aug 31 21:37:18.337 2009   (  0.00) secs
                     right PMC Actuator 131 set force read error: -3

 146  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:20.507 2009  to  Mon Aug 31 21:37:20.507 2009   (  0.00) secs
                     right PMC Actuator 327 get force read error: -3

 147  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:20.810 2009  to  Mon Aug 31 21:37:20.810 2009   (  0.00) secs
                     right PMC Actuator 101 set force read error: -3

 148  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:22.134 2009  to  Mon Aug 31 21:37:22.134 2009   (  0.00) secs
                     right PMC Actuator 106 set force read error: -3

 149  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:23.458 2009  to  Mon Aug 31 21:37:23.458 2009   (  0.00) secs
                     right PMC Actuator 114 set force read error: -3

 150  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:24.116 2009  to  Mon Aug 31 21:37:24.116 2009   (  0.00) secs
                     right PMC Actuator 438 get force read error: -3

 151  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:27.975 2009  to  Mon Aug 31 21:37:27.975 2009   (  0.00) secs
                     right PMC Actuator 304 set force read error: -3

 152  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:28.026 2009  to  Mon Aug 31 21:37:28.026 2009   (  0.00) secs
                     right PMC Actuator 306 set force read error: -3

 153  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:38.191 2009  to  Mon Aug 31 21:37:38.191 2009   (  0.00) secs
                     right PMC Actuator 229 get force read error: -3

 154  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:40.313 2009  to  Mon Aug 31 21:37:40.313 2009   (  0.00) secs
                     right PMC Actuator 310 get force read error: -3

 155  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:45.429 2009  to  Mon Aug 31 21:37:45.429 2009   (  0.00) secs
                     right PMC Actuator 343 get force read error: -3

 156  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:46.204 2009  to  Mon Aug 31 21:37:46.204 2009   (  0.00) secs
                     right PMC Actuator 341 get force read error: -3

 157  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:48.628 2009  to  Mon Aug 31 21:37:48.628 2009   (  0.00) secs
                     right PMC Actuator 107 set force read error: -3

 158  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:43.487 2009  to  Mon Aug 31 21:47:43.487 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 159  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:44.040 2009  to  Mon Aug 31 21:47:44.040 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 160  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:45.192 2009  to  Mon Aug 31 21:47:45.192 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 161  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:46.002 2009  to  Mon Aug 31 21:47:46.002 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 162  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:47.065 2009  to  Mon Aug 31 21:47:47.065 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 163  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:48.179 2009  to  Mon Aug 31 21:47:48.179 2009   (  0.00) secs
                     right PMC Hardpoint 5 get data time out

 164  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:49.241 2009  to  Mon Aug 31 21:47:49.241 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 165  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:50.050 2009  to  Mon Aug 31 21:47:50.050 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 166  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:51.191 2009  to  Mon Aug 31 21:47:51.191 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 167  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:52.250 2009  to  Mon Aug 31 21:47:52.250 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 168  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:53.107 2009  to  Mon Aug 31 21:47:53.107 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 169  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:54.216 2009  to  Mon Aug 31 21:47:54.216 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 170  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:55.023 2009  to  Mon Aug 31 21:47:55.023 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 171  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:56.132 2009  to  Mon Aug 31 21:47:56.132 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 172  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:57.192 2009  to  Mon Aug 31 21:47:57.192 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 173  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:58.047 2009  to  Mon Aug 31 21:47:58.047 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 174  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:59.106 2009  to  Mon Aug 31 21:47:59.106 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 175  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:47:59.662 2009  to  Mon Aug 31 21:47:59.662 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 176  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:47:59.713 2009  to  Mon Aug 31 21:47:59.713 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 177  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:47:59.763 2009  to  Mon Aug 31 21:47:59.763 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 178  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:47:59.814 2009  to  Mon Aug 31 21:47:59.814 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 179  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:00.117 2009  to  Mon Aug 31 21:48:00.117 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 180  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:01.012 2009  to  Mon Aug 31 21:48:01.012 2009   (  0.00) secs
                     right PMC Hardpoint 5 get data time out

 181  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:02.072 2009  to  Mon Aug 31 21:48:02.072 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 182  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:03.133 2009  to  Mon Aug 31 21:48:03.133 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 183  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:04.240 2009  to  Mon Aug 31 21:48:04.240 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 184  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:05.045 2009  to  Mon Aug 31 21:48:05.045 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 185  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:06.200 2009  to  Mon Aug 31 21:48:06.200 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 186  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:07.008 2009  to  Mon Aug 31 21:48:07.008 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 187  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:48:25.385 2009  to  Mon Aug 31 21:48:25.385 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 188  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:48:25.486 2009  to  Mon Aug 31 21:48:25.486 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 189  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:48:25.435 2009  to  Mon Aug 31 21:48:25.435 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 190  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:48:25.536 2009  to  Mon Aug 31 21:48:25.536 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 191  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:48:51.072 2009  to  Mon Aug 31 21:48:51.072 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 192  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:48:51.376 2009  to  Mon Aug 31 21:48:51.376 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 193  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:48:51.427 2009  to  Mon Aug 31 21:48:51.427 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 194  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:48:51.478 2009  to  Mon Aug 31 21:48:51.478 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 195  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:49:16.811 2009  to  Mon Aug 31 21:49:16.811 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 196  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:49:16.862 2009  to  Mon Aug 31 21:49:16.862 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 197  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:49:17.164 2009  to  Mon Aug 31 21:49:17.164 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 198  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:49:17.266 2009  to  Mon Aug 31 21:49:17.266 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 199  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:49:42.554 2009  to  Mon Aug 31 21:49:42.554 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 200  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:49:42.605 2009  to  Mon Aug 31 21:49:42.605 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 201  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:49:42.906 2009  to  Mon Aug 31 21:49:42.906 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 202  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:49:42.957 2009  to  Mon Aug 31 21:49:42.957 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 203  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:50:08.530 2009  to  Mon Aug 31 21:50:08.530 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 204  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:50:08.631 2009  to  Mon Aug 31 21:50:08.631 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 205  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:50:08.581 2009  to  Mon Aug 31 21:50:08.581 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 206  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:50:08.681 2009  to  Mon Aug 31 21:50:08.681 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 207  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:50:34.301 2009  to  Mon Aug 31 21:50:34.301 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 208  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:50:34.404 2009  to  Mon Aug 31 21:50:34.404 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 209  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:50:34.353 2009  to  Mon Aug 31 21:50:34.353 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 210  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:50:34.455 2009  to  Mon Aug 31 21:50:34.455 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 211  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:00.052 2009  to  Mon Aug 31 21:51:00.052 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 212  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:00.001 2009  to  Mon Aug 31 21:51:00.001 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 213  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:00.157 2009  to  Mon Aug 31 21:51:00.157 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 214  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:00.209 2009  to  Mon Aug 31 21:51:00.209 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 215  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:25.807 2009  to  Mon Aug 31 21:51:25.807 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 216  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:25.756 2009  to  Mon Aug 31 21:51:25.756 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 217  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:25.858 2009  to  Mon Aug 31 21:51:25.858 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 218  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:25.909 2009  to  Mon Aug 31 21:51:25.909 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 219  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:51.432 2009  to  Mon Aug 31 21:51:51.432 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 220  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:51.556 2009  to  Mon Aug 31 21:51:51.556 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 221  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:51.505 2009  to  Mon Aug 31 21:51:51.505 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 222  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:51.607 2009  to  Mon Aug 31 21:51:51.607 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 223  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:52:17.183 2009  to  Mon Aug 31 21:52:17.183 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 224  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:52:17.285 2009  to  Mon Aug 31 21:52:17.285 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 225  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:52:17.234 2009  to  Mon Aug 31 21:52:17.234 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 226  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:52:17.587 2009  to  Mon Aug 31 21:52:17.587 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 227  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:52:42.971 2009  to  Mon Aug 31 21:52:42.971 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 228  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:52:42.920 2009  to  Mon Aug 31 21:52:42.920 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 229  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:52:43.023 2009  to  Mon Aug 31 21:52:43.023 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 230  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:52:43.379 2009  to  Mon Aug 31 21:52:43.379 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 231  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:53:08.699 2009  to  Mon Aug 31 21:53:08.699 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 232  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:53:08.801 2009  to  Mon Aug 31 21:53:08.801 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 233  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:53:08.750 2009  to  Mon Aug 31 21:53:08.750 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 234  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:53:09.105 2009  to  Mon Aug 31 21:53:09.105 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 235  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:53:34.542 2009  to  Mon Aug 31 21:53:34.542 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 236  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:53:34.491 2009  to  Mon Aug 31 21:53:34.491 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 237  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:53:34.593 2009  to  Mon Aug 31 21:53:34.593 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 238  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:53:34.643 2009  to  Mon Aug 31 21:53:34.643 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 239  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:00.268 2009  to  Mon Aug 31 21:54:00.268 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 240  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:00.319 2009  to  Mon Aug 31 21:54:00.319 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 241  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:00.622 2009  to  Mon Aug 31 21:54:00.622 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 242  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:25.968 2009  to  Mon Aug 31 21:54:25.968 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 243  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:26.271 2009  to  Mon Aug 31 21:54:26.271 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 244  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:26.373 2009  to  Mon Aug 31 21:54:26.373 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 245  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:51.946 2009  to  Mon Aug 31 21:54:51.946 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 246  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:51.997 2009  to  Mon Aug 31 21:54:51.997 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 247  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:52.100 2009  to  Mon Aug 31 21:54:52.100 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 248  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:55:17.691 2009  to  Mon Aug 31 21:55:17.691 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 249  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:55:17.794 2009  to  Mon Aug 31 21:55:17.794 2009   (  0.00) secs
                     right PMC -15 volt failure: -0.00 V, requirement is -14.00

 250  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:55:17.844 2009  to  Mon Aug 31 21:55:17.844 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 251  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:55:43.266 2009  to  Mon Aug 31 21:55:43.266 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 252  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:55:43.569 2009  to  Mon Aug 31 21:55:43.569 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 253  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:55:43.619 2009  to  Mon Aug 31 21:55:43.619 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 254  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:56:09.193 2009  to  Mon Aug 31 21:56:09.193 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 255  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:56:09.243 2009  to  Mon Aug 31 21:56:09.243 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 256  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:56:09.343 2009  to  Mon Aug 31 21:56:09.343 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 257  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:15.455 2009  to  Mon Aug 31 21:56:15.455 2009   (  0.00) secs
                     right PMC Actuator 127 get force read error: -3

 258  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:17.322 2009  to  Mon Aug 31 21:56:17.322 2009   (  0.00) secs
                     right PMC Actuator 215 get force read error: -3

 259  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:19.323 2009  to  Mon Aug 31 21:56:19.323 2009   (  0.00) secs
                     right PMC Actuator 303 get force read error: -3

 260  FAILED    PMC        command.recoverPanic                                          Mon Aug 31 22:30:07.359 2009  to  Mon Aug 31 22:30:12.411 2009   (  5.05) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 261  FAILED    PMC        mirror.panic                                                  Mon Aug 31 22:30:07.651 2009  to  Mon Aug 31 22:30:07.651 2009   (  0.00) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 262  FAILED    PMC        command.recoverPanic                                          Mon Aug 31 22:50:38.645 2009  to  Mon Aug 31 22:50:43.699 2009   (  5.05) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 263  FAILED    PMC        mirror.panic                                                  Mon Aug 31 22:50:38.891 2009  to  Mon Aug 31 22:50:38.891 2009   (  0.00) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 264  STARTUP   PMC        startup                                                       Mon Aug 31 22:54:26.407 2009  to  Mon Aug 31 22:54:26.407 2009   (  0.00) secs
                     right PMC subsystem started, version 5.0

 265  FAILED    PMC        telemetryError                                                Mon Aug 31 22:54:26.460 2009  to  Mon Aug 31 22:54:26.460 2009   (  0.00) secs
                     right PMC telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 266  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 22:54:35.688 2009  to  Mon Aug 31 22:54:35.688 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: This singleton has not been initialized

 267  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 22:54:35.790 2009  to  Mon Aug 31 22:54:35.790 2009   (  0.00) secs
                     right PMC Motor telemetry error: This singleton has not been initialized

 268  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 22:54:35.892 2009  to  Mon Aug 31 22:54:35.892 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: This singleton has not been initialized

 269  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 22:54:35.994 2009  to  Mon Aug 31 22:54:35.994 2009   (  0.00) secs
                     right PMC Mirror telemetry error: This singleton has not been initialized

 270  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 22:54:36.147 2009  to  Mon Aug 31 22:54:36.147 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: This singleton has not been initialized

 271  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 22:54:37.404 2009  to  Mon Aug 31 22:54:37.404 2009   (  0.00) secs
                     right PMC Thermal telemetry error: This singleton has not been initialized

 272  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 22:54:37.505 2009  to  Mon Aug 31 22:54:37.505 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: This singleton has not been initialized

 273  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 22:54:38.922 2009  to  Mon Aug 31 22:54:38.922 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 274  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 22:54:38.991 2009  to  Mon Aug 31 22:54:38.991 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: No telemetry since telemeter registration failed.

 275  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 22:54:39.017 2009  to  Mon Aug 31 22:54:39.017 2009   (  0.00) secs
                     right PMC Mirror telemetry error: No telemetry since telemeter registration failed.

 276  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 22:54:39.099 2009  to  Mon Aug 31 22:54:39.099 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: No telemetry since telemeter registration failed.

 277  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 22:54:39.086 2009  to  Mon Aug 31 22:54:39.086 2009   (  0.00) secs
                     right PMC Motor telemetry error: No telemetry since telemeter registration failed.

 278  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 22:54:39.178 2009  to  Mon Aug 31 22:54:39.178 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: No telemetry since telemeter registration failed.

 279  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Aug 31 22:55:13.604 2009  to  Mon Aug 31 22:55:13.604 2009   (  0.00) secs
                     right PMC Actuator 429 force monitor 1 PANIC! 159.1 lbs, limit is 0.0

 280  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Aug 31 22:55:25.881 2009  to  Mon Aug 31 22:55:25.881 2009   (  0.00) secs
                     right PMC Actuator 234 force monitor 1 PANIC! -169.2 lbs, limit is 0.0

 281  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 22:55:27.882 2009  to  Mon Aug 31 22:55:27.882 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 282  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Sep  1 03:04:50.099 2009  to  Tue Sep  1 03:05:22.401 2009   ( 32.30) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 283  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Sep  1 03:05:54.463 2009  to  Tue Sep  1 03:06:00.724 2009   (  6.26) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 284  FAILED    PMC        VxInterface.lengthError                                       Tue Sep  1 05:04:18.562 2009  to  Tue Sep  1 05:04:18.562 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 285  FAILED    PMC        VxInterface.close                                             Tue Sep  1 05:04:18.613 2009  to  Tue Sep  1 05:04:18.613 2009   (  0.00) secs
                     right PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.10    0.11    0.05    0.32   100.0 %         41         41                      
                                                                       0.10    0.11    0.05    0.32
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    1.99    3.63    1.58    8.59   100.0 %         27         27                      
                                                                       1.99    3.63    1.58    8.59
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.20    0.36    0.05    0.55   100.0 %          8          8                      
                                                                       0.20    0.36    0.05    0.55
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   17.57    8.90    1.37   90.50    97.3 %         73         71          2           
                                                                      17.59    8.61    1.37   90.50
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    4.18    4.18    4.18   100.0 %          1          1                      
                                                                       0.00    4.18    4.18    4.18
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.28    2.31    2.17    2.93   100.0 %         10         10                      
                                                                       0.28    2.31    2.17    2.93
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.04    0.08    0.05    0.18    77.8 %          9          7          2           
                                                                       0.05    0.09    0.05    0.18
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   40.66   58.13    7.70   93.87   100.0 %          5          5                      
                                                                      40.66   58.13    7.70   93.87
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    1.53    7.15    5.48    8.49   100.0 %          3          3                      
                                                                       1.53    7.15    5.48    8.49
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    1.99    3.53    1.47    8.48   100.0 %         27         27                      
                                                                       1.99    3.53    1.47    8.48
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.06    0.05    0.10   100.0 %         11         11                      
                                                                       0.01    0.06    0.05    0.10
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .   12.97    6.12    0.16   42.83    70.0 %         10          7          3           
                                                                      15.08    8.64    2.46   42.83
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         11         11                      
                                                                       0.00    0.05    0.05    0.06
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.03    0.08    0.05    0.11   100.0 %          6          6                      
                                                                       0.03    0.08    0.05    0.11
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .  211.83   89.70    2.69  522.10    83.3 %          6          5          1           
                                                                       0.31    3.22    2.69    3.48
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.01    0.07    0.05    0.08   100.0 %          6          6                      
                                                                       0.01    0.07    0.05    0.08

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Sep  1 02:30:00.148 2009  to  Tue Sep  1 02:30:00.202 2009   (  0.05) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Sep  1 02:30:07.603 2009  to  Tue Sep  1 02:30:07.655 2009   (  0.05) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Sep  1 03:04:50.044 2009  to  Tue Sep  1 03:05:22.461 2009   ( 32.42) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Sep  1 03:05:54.408 2009  to  Tue Sep  1 03:06:00.785 2009   (  6.38) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:25:45.937 2009  to  Tue Sep  1 05:25:46.121 2009   (  0.18) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

   6  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Sep  1 05:25:45.947 2009  to  Tue Sep  1 05:34:28.042 2009   (522.10) secs
                     left PSF tertiary mirror adjustMirrorCollimation failed for rzColl 0 with argument 0.0000000e+00 because Invalid buffer: RPCERROR

   7  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:43:02.604 2009  to  Tue Sep  1 05:43:02.959 2009   (  0.36) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

   8  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:53:00.120 2009  to  Tue Sep  1 05:53:00.285 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:01:52.490 2009  to  Mon Aug 31 20:01:52.490 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.69 V, requirement is 7.65

   2  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:50.791 2009  to  Mon Aug 31 20:02:50.791 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.83 V, requirement is 7.65

   3  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:52.358 2009  to  Mon Aug 31 20:02:52.358 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

   4  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:55.187 2009  to  Mon Aug 31 20:02:55.187 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.87 V, requirement is 7.65

   5  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:02:58.509 2009  to  Mon Aug 31 20:02:58.509 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.83 V, requirement is 7.65

   6  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:06.375 2009  to  Mon Aug 31 20:03:06.375 2009   (  0.00) secs
                     right PMC Actuator 101 set force time out

   7  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:07.185 2009  to  Mon Aug 31 20:03:07.185 2009   (  0.00) secs
                     right PMC Actuator 122 set force time out

   8  FAILED    PMC        actuator.setForce.timeout                                     Mon Aug 31 20:03:08.498 2009  to  Mon Aug 31 20:03:08.498 2009   (  0.00) secs
                     right PMC Actuator 218 set force time out

   9  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:09.305 2009  to  Mon Aug 31 20:03:09.305 2009   (  0.00) secs
                     right PMC Actuator 223 set force bad return: 164 instead of 9

  10  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.356 2009  to  Mon Aug 31 20:03:09.356 2009   (  0.00) secs
                     right PMC Actuator 304 has been reset

  11  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.406 2009  to  Mon Aug 31 20:03:09.406 2009   (  0.00) secs
                     right PMC Actuator 238 has been reset

  12  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.457 2009  to  Mon Aug 31 20:03:09.457 2009   (  0.00) secs
                     right PMC Actuator 303 has been reset

  13  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.508 2009  to  Mon Aug 31 20:03:09.508 2009   (  0.00) secs
                     right PMC Actuator 302 has been reset

  14  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.559 2009  to  Mon Aug 31 20:03:09.559 2009   (  0.00) secs
                     right PMC Actuator 235 has been reset

  15  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.610 2009  to  Mon Aug 31 20:03:09.610 2009   (  0.00) secs
                     right PMC Actuator 236 has been reset

  16  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.661 2009  to  Mon Aug 31 20:03:09.661 2009   (  0.00) secs
                     right PMC Actuator 240 has been reset

  17  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:09.713 2009  to  Mon Aug 31 20:03:09.713 2009   (  0.00) secs
                     right PMC Actuator 305 has been reset

  18  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.234 2009  to  Mon Aug 31 20:03:10.234 2009   (  0.00) secs
                     right PMC Actuator 316 has been reset

  19  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.438 2009  to  Mon Aug 31 20:03:10.438 2009   (  0.00) secs
                     right PMC Actuator 312 has been reset

  20  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.643 2009  to  Mon Aug 31 20:03:10.643 2009   (  0.00) secs
                     right PMC Actuator 307 has been reset

  21  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:10.848 2009  to  Mon Aug 31 20:03:10.848 2009   (  0.00) secs
                     right PMC Actuator 309 has been reset

  22  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.053 2009  to  Mon Aug 31 20:03:11.053 2009   (  0.00) secs
                     right PMC Actuator 306 has been reset

  23  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.257 2009  to  Mon Aug 31 20:03:11.257 2009   (  0.00) secs
                     right PMC Actuator 311 has been reset

  24  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.462 2009  to  Mon Aug 31 20:03:11.462 2009   (  0.00) secs
                     right PMC Actuator 308 has been reset

  25  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:11.666 2009  to  Mon Aug 31 20:03:11.666 2009   (  0.00) secs
                     right PMC Actuator 317 has been reset

  26  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.123 2009  to  Mon Aug 31 20:03:12.123 2009   (  0.00) secs
                     right PMC Actuator 321 has been reset

  27  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.326 2009  to  Mon Aug 31 20:03:12.326 2009   (  0.00) secs
                     right PMC Actuator 322 has been reset

  28  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.560 2009  to  Mon Aug 31 20:03:12.560 2009   (  0.00) secs
                     right PMC Actuator 323 has been reset

  29  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.765 2009  to  Mon Aug 31 20:03:12.765 2009   (  0.00) secs
                     right PMC Actuator 313 has been reset

  30  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:12.969 2009  to  Mon Aug 31 20:03:12.969 2009   (  0.00) secs
                     right PMC Actuator 310 has been reset

  31  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.174 2009  to  Mon Aug 31 20:03:13.174 2009   (  0.00) secs
                     right PMC Actuator 315 has been reset

  32  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.378 2009  to  Mon Aug 31 20:03:13.378 2009   (  0.00) secs
                     right PMC Actuator 319 has been reset

  33  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.582 2009  to  Mon Aug 31 20:03:13.582 2009   (  0.00) secs
                     right PMC Actuator 320 has been reset

  34  FAILED    PMC        actuator.reset                                                Mon Aug 31 20:03:13.786 2009  to  Mon Aug 31 20:03:13.786 2009   (  0.00) secs
                     right PMC Actuator 335 has been reset

  35  FAILED    PMC        mirror.panic                                                  Mon Aug 31 20:03:27.482 2009  to  Mon Aug 31 20:03:27.482 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  36  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:32.046 2009  to  Mon Aug 31 20:03:32.046 2009   (  0.00) secs
                     right PMC Actuator 329 set force bad return: 237 instead of 15

  37  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 20:03:32.551 2009  to  Mon Aug 31 20:03:32.551 2009   (  0.00) secs
                     right PMC Actuator 418 set force read error: -3

  38  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:03:34.371 2009  to  Mon Aug 31 20:03:34.371 2009   (  0.00) secs
                     right PMC Actuator 432 set force bad return: 128 instead of 18

  39  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:03:45.718 2009  to  Mon Aug 31 20:03:45.718 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.74 V, requirement is 7.65

  40  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:27.685 2009  to  Mon Aug 31 20:08:27.685 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.92 V, requirement is 7.65

  41  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:30.011 2009  to  Mon Aug 31 20:08:30.011 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

  42  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:08:31.072 2009  to  Mon Aug 31 20:08:31.072 2009   (  0.00) secs
                     right PMC 7 volt failure: 8.01 V, requirement is 7.65

  43  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:09:05.916 2009  to  Mon Aug 31 20:09:05.916 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.74 V, requirement is 7.65

  44  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 20:09:06.473 2009  to  Mon Aug 31 20:09:06.473 2009   (  0.00) secs
                     right PMC 7 volt failure: 7.78 V, requirement is 7.65

  45  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 20:12:19.733 2009  to  Mon Aug 31 20:12:19.733 2009   (  0.00) secs
                     right PMC Actuator 241 get force read error: -3

  46  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:19.784 2009  to  Mon Aug 31 20:12:19.784 2009   (  0.00) secs
                     right PMC Actuator 103 set force bad return: 196 instead of 1

  47  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 20:12:20.087 2009  to  Mon Aug 31 20:12:20.087 2009   (  0.00) secs
                     right PMC Actuator 238 get force read error: -3

  48  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:20.137 2009  to  Mon Aug 31 20:12:20.137 2009   (  0.00) secs
                     right PMC Actuator 102 set force bad return: 254 instead of 1

  49  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 20:12:22.535 2009  to  Mon Aug 31 20:12:22.535 2009   (  0.00) secs
                     right PMC Actuator 106 set force bad return: 253 instead of 1

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:30:27.834 2009  to  Mon Aug 31 20:30:27.834 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:30:27.839 2009  to  Mon Aug 31 20:30:27.839 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:30:27.945 2009  to  Mon Aug 31 20:30:27.945 2009   (  0.00) secs
                     drive cabinet has turned on.

  53  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:30:29.851 2009  to  Mon Aug 31 20:30:29.851 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  54  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:30:29.856 2009  to  Mon Aug 31 20:30:29.856 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  55  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:30:45.662 2009  to  Mon Aug 31 20:30:45.662 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

  56  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:30:45.671 2009  to  Mon Aug 31 20:30:45.671 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:31:27.057 2009  to  Mon Aug 31 20:31:27.057 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:31:27.062 2009  to  Mon Aug 31 20:31:27.062 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:31:27.153 2009  to  Mon Aug 31 20:31:27.153 2009   (  0.00) secs
                     drive cabinet has turned on.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.159 2009  to  Mon Aug 31 20:31:28.159 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.160 2009  to  Mon Aug 31 20:31:28.160 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  62  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.160 2009  to  Mon Aug 31 20:31:28.160 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  63  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.161 2009  to  Mon Aug 31 20:31:28.161 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  64  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.162 2009  to  Mon Aug 31 20:31:28.162 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.163 2009  to  Mon Aug 31 20:31:28.163 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.163 2009  to  Mon Aug 31 20:31:28.163 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:31:28.164 2009  to  Mon Aug 31 20:31:28.164 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:31:30.788 2009  to  Mon Aug 31 20:31:30.788 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  69  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:31:30.793 2009  to  Mon Aug 31 20:31:30.793 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  70  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Mon Aug 31 20:33:09.179 2009  to  Mon Aug 31 20:33:09.179 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

  71  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:33:24.524 2009  to  Mon Aug 31 20:33:24.524 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

  72  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:33:24.522 2009  to  Mon Aug 31 20:33:24.522 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:54:24.588 2009  to  Mon Aug 31 20:54:24.588 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Aug 31 20:54:24.603 2009  to  Mon Aug 31 20:54:24.603 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Aug 31 20:54:24.701 2009  to  Mon Aug 31 20:54:24.701 2009   (  0.00) secs
                     drive cabinet has turned on.

  76  FAILED    OSS        side[0].swa                                                   Mon Aug 31 20:54:25.328 2009  to  Mon Aug 31 20:54:25.328 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

  77  FAILED    OSS        side[1].swa                                                   Mon Aug 31 20:54:25.296 2009  to  Mon Aug 31 20:54:25.296 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

  78  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.728 2009  to  Mon Aug 31 20:54:25.728 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  79  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.729 2009  to  Mon Aug 31 20:54:25.729 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  80  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.730 2009  to  Mon Aug 31 20:54:25.730 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  81  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.730 2009  to  Mon Aug 31 20:54:25.730 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  82  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.732 2009  to  Mon Aug 31 20:54:25.732 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  83  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.732 2009  to  Mon Aug 31 20:54:25.732 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  84  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.733 2009  to  Mon Aug 31 20:54:25.733 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  85  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Aug 31 20:54:25.734 2009  to  Mon Aug 31 20:54:25.734 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  86  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:23.587 2009  to  Mon Aug 31 21:00:23.587 2009   (  0.00) secs
                     right PMC Actuator 237 get force read error: -3

  87  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:23.639 2009  to  Mon Aug 31 21:00:23.639 2009   (  0.00) secs
                     right PMC Actuator 105 set force bad return: 219 instead of 1

  88  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:24.194 2009  to  Mon Aug 31 21:00:24.194 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

  89  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:24.245 2009  to  Mon Aug 31 21:00:24.245 2009   (  0.00) secs
                     right PMC Actuator 102 set force bad return: 248 instead of 1

  90  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:00:26.931 2009  to  Mon Aug 31 21:00:26.931 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

  91  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:00:27.033 2009  to  Mon Aug 31 21:00:27.033 2009   (  0.00) secs
                     right PMC Actuator 109 set force read error: -3

  92  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:00:27.337 2009  to  Mon Aug 31 21:00:27.337 2009   (  0.00) secs
                     right PMC Actuator 138 set force bad return: 2 instead of 5

  93  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.357 2009  to  Mon Aug 31 21:10:15.357 2009   (  0.00) secs
                     right PMC PMC closing network connection

  94  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.408 2009  to  Mon Aug 31 21:10:15.408 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

  95  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.459 2009  to  Mon Aug 31 21:10:15.459 2009   (  0.00) secs
                     right PMC Async closing network connection

  96  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.510 2009  to  Mon Aug 31 21:10:15.510 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  97  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.561 2009  to  Mon Aug 31 21:10:15.561 2009   (  0.00) secs
                     right PMC Mount closing network connection

  98  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.612 2009  to  Mon Aug 31 21:10:15.612 2009   (  0.00) secs
                     right PMC Mirror closing network connection

  99  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.663 2009  to  Mon Aug 31 21:10:15.663 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 100  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.714 2009  to  Mon Aug 31 21:10:15.714 2009   (  0.00) secs
                     right PMC Motor closing network connection

 101  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.765 2009  to  Mon Aug 31 21:10:15.765 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

 102  FAILED    PMC        VxInterface.close                                             Mon Aug 31 21:10:15.817 2009  to  Mon Aug 31 21:10:15.817 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 103  SHUTDOWN  PMC        shutdown                                                      Mon Aug 31 21:10:15.868 2009  to  Mon Aug 31 21:10:15.868 2009   (  0.00) secs
                     right PMC subsystem shut down

 104  FAILED    PMC        telemetryError                                                Mon Aug 31 21:10:21.151 2009  to  Mon Aug 31 21:10:21.151 2009   (  0.00) secs
                     right PMC telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 105  STARTUP   PMC        startup                                                       Mon Aug 31 21:10:21.098 2009  to  Mon Aug 31 21:10:21.098 2009   (  0.00) secs
                     right PMC subsystem started, version 5.0

 106  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:21.994 2009  to  Mon Aug 31 21:10:21.994 2009   (  0.00) secs
                     right PMC Actuator 101 telemetry error: This singleton has not been initialized

 107  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.045 2009  to  Mon Aug 31 21:10:22.045 2009   (  0.00) secs
                     right PMC Actuator 102 telemetry error: This singleton has not been initialized

 108  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.096 2009  to  Mon Aug 31 21:10:22.096 2009   (  0.00) secs
                     right PMC Actuator 103 telemetry error: This singleton has not been initialized

 109  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.147 2009  to  Mon Aug 31 21:10:22.147 2009   (  0.00) secs
                     right PMC Actuator 104 telemetry error: This singleton has not been initialized

 110  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.198 2009  to  Mon Aug 31 21:10:22.198 2009   (  0.00) secs
                     right PMC Actuator 105 telemetry error: This singleton has not been initialized

 111  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.249 2009  to  Mon Aug 31 21:10:22.249 2009   (  0.00) secs
                     right PMC Actuator 106 telemetry error: This singleton has not been initialized

 112  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.300 2009  to  Mon Aug 31 21:10:22.300 2009   (  0.00) secs
                     right PMC Actuator 107 telemetry error: This singleton has not been initialized

 113  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.351 2009  to  Mon Aug 31 21:10:22.351 2009   (  0.00) secs
                     right PMC Actuator 108 telemetry error: This singleton has not been initialized

 114  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.401 2009  to  Mon Aug 31 21:10:22.401 2009   (  0.00) secs
                     right PMC Actuator 109 telemetry error: This singleton has not been initialized

 115  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.451 2009  to  Mon Aug 31 21:10:22.451 2009   (  0.00) secs
                     right PMC Actuator 110 telemetry error: This singleton has not been initialized

 116  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.502 2009  to  Mon Aug 31 21:10:22.502 2009   (  0.00) secs
                     right PMC Actuator 111 telemetry error: This singleton has not been initialized

 117  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.552 2009  to  Mon Aug 31 21:10:22.552 2009   (  0.00) secs
                     right PMC Actuator 112 telemetry error: This singleton has not been initialized

 118  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.604 2009  to  Mon Aug 31 21:10:22.604 2009   (  0.00) secs
                     right PMC Actuator 113 telemetry error: This singleton has not been initialized

 119  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.654 2009  to  Mon Aug 31 21:10:22.654 2009   (  0.00) secs
                     right PMC Actuator 114 telemetry error: This singleton has not been initialized

 120  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.772 2009  to  Mon Aug 31 21:10:22.772 2009   (  0.00) secs
                     right PMC Actuator 115 telemetry error: This singleton has not been initialized

 121  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.822 2009  to  Mon Aug 31 21:10:22.822 2009   (  0.00) secs
                     right PMC Actuator 116 telemetry error: This singleton has not been initialized

 122  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.872 2009  to  Mon Aug 31 21:10:22.872 2009   (  0.00) secs
                     right PMC Actuator 117 telemetry error: This singleton has not been initialized

 123  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.922 2009  to  Mon Aug 31 21:10:22.922 2009   (  0.00) secs
                     right PMC Actuator 118 telemetry error: This singleton has not been initialized

 124  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:22.972 2009  to  Mon Aug 31 21:10:22.972 2009   (  0.00) secs
                     right PMC Actuator 119 telemetry error: This singleton has not been initialized

 125  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.023 2009  to  Mon Aug 31 21:10:23.023 2009   (  0.00) secs
                     right PMC Actuator 120 telemetry error: This singleton has not been initialized

 126  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.073 2009  to  Mon Aug 31 21:10:23.073 2009   (  0.00) secs
                     right PMC Actuator 121 telemetry error: This singleton has not been initialized

 127  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.123 2009  to  Mon Aug 31 21:10:23.123 2009   (  0.00) secs
                     right PMC Actuator 122 telemetry error: This singleton has not been initialized

 128  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.173 2009  to  Mon Aug 31 21:10:23.173 2009   (  0.00) secs
                     right PMC Actuator 123 telemetry error: This singleton has not been initialized

 129  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.223 2009  to  Mon Aug 31 21:10:23.223 2009   (  0.00) secs
                     right PMC Actuator 124 telemetry error: This singleton has not been initialized

 130  FAILED    PMC        actuator.telemetryError                                       Mon Aug 31 21:10:23.273 2009  to  Mon Aug 31 21:10:23.273 2009   (  0.00) secs
                     right PMC Actuator 125 telemetry error: This singleton has not been initialized

 131  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 21:10:30.312 2009  to  Mon Aug 31 21:10:30.312 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: This singleton has not been initialized

 132  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 21:10:30.412 2009  to  Mon Aug 31 21:10:30.412 2009   (  0.00) secs
                     right PMC Motor telemetry error: This singleton has not been initialized

 133  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 21:10:30.584 2009  to  Mon Aug 31 21:10:30.584 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: This singleton has not been initialized

 134  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 21:10:30.684 2009  to  Mon Aug 31 21:10:30.684 2009   (  0.00) secs
                     right PMC Mirror telemetry error: This singleton has not been initialized

 135  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 21:10:30.834 2009  to  Mon Aug 31 21:10:30.834 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: This singleton has not been initialized

 136  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 21:10:32.091 2009  to  Mon Aug 31 21:10:32.091 2009   (  0.00) secs
                     right PMC Thermal telemetry error: This singleton has not been initialized

 137  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 21:10:32.194 2009  to  Mon Aug 31 21:10:32.194 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: This singleton has not been initialized

 138  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 21:10:33.477 2009  to  Mon Aug 31 21:10:33.477 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: No telemetry since telemeter registration failed.

 139  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 21:10:33.518 2009  to  Mon Aug 31 21:10:33.518 2009   (  0.00) secs
                     right PMC Mirror telemetry error: No telemetry since telemeter registration failed.

 140  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 21:10:33.458 2009  to  Mon Aug 31 21:10:33.458 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 141  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 21:10:33.540 2009  to  Mon Aug 31 21:10:33.540 2009   (  0.00) secs
                     right PMC Motor telemetry error: No telemetry since telemeter registration failed.

 142  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 21:10:33.694 2009  to  Mon Aug 31 21:10:33.694 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: No telemetry since telemeter registration failed.

 143  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 21:10:33.799 2009  to  Mon Aug 31 21:10:33.799 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: No telemetry since telemeter registration failed.

 144  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 21:10:42.381 2009  to  Mon Aug 31 21:10:42.381 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 145  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:48.825 2009  to  Mon Aug 31 21:33:48.825 2009   (  0.00) secs
                     right PMC Actuator 128 set force bad return: 243 instead of 3

 146  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:48.875 2009  to  Mon Aug 31 21:33:48.875 2009   (  0.00) secs
                     right PMC Actuator 119 set force read error: -3

 147  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:49.179 2009  to  Mon Aug 31 21:33:49.179 2009   (  0.00) secs
                     right PMC Actuator 135 set force bad return: 31 instead of 4

 148  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:49.593 2009  to  Mon Aug 31 21:33:49.593 2009   (  0.00) secs
                     right PMC Actuator 134 set force read error: -3

 149  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:52.050 2009  to  Mon Aug 31 21:33:52.050 2009   (  0.00) secs
                     right PMC Actuator 136 set force bad return: 67 instead of 5

 150  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:33:57.593 2009  to  Mon Aug 31 21:33:57.593 2009   (  0.00) secs
                     right PMC Actuator 219 set force read error: -3

 151  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:57.644 2009  to  Mon Aug 31 21:33:57.644 2009   (  0.00) secs
                     right PMC Actuator 220 set force bad return: 254 instead of 8

 152  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:33:59.708 2009  to  Mon Aug 31 21:33:59.708 2009   (  0.00) secs
                     right PMC Actuator 107 set force bad return: 243 instead of 1

 153  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:00.011 2009  to  Mon Aug 31 21:34:00.011 2009   (  0.00) secs
                     right PMC Actuator 102 set force read error: -3

 154  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:00.314 2009  to  Mon Aug 31 21:34:00.314 2009   (  0.00) secs
                     right PMC Actuator 111 set force bad return: 244 instead of 2

 155  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:02.822 2009  to  Mon Aug 31 21:34:02.822 2009   (  0.00) secs
                     right PMC Actuator 116 set force bad return: 253 instead of 2

 156  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:11.909 2009  to  Mon Aug 31 21:34:11.909 2009   (  0.00) secs
                     right PMC Actuator 106 set force read error: -3

 157  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:11.960 2009  to  Mon Aug 31 21:34:11.960 2009   (  0.00) secs
                     right PMC Actuator 114 set force bad return: 254 instead of 2

 158  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:12.011 2009  to  Mon Aug 31 21:34:12.011 2009   (  0.00) secs
                     right PMC Actuator 107 set force read error: -3

 159  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:12.062 2009  to  Mon Aug 31 21:34:12.062 2009   (  0.00) secs
                     right PMC Actuator 112 set force bad return: 255 instead of 2

 160  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:34:14.131 2009  to  Mon Aug 31 21:34:14.131 2009   (  0.00) secs
                     right PMC Actuator 140 get force read error: -3

 161  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:14.181 2009  to  Mon Aug 31 21:34:14.181 2009   (  0.00) secs
                     right PMC Actuator 107 set force bad return: 239 instead of 1

 162  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:14.232 2009  to  Mon Aug 31 21:34:14.232 2009   (  0.00) secs
                     right PMC Actuator 103 set force read error: -3

 163  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:17.079 2009  to  Mon Aug 31 21:34:17.079 2009   (  0.00) secs
                     right PMC Actuator 108 set force bad return: 246 instead of 1

 164  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:34.811 2009  to  Mon Aug 31 21:34:34.811 2009   (  0.00) secs
                     right PMC Actuator 333 set force bad return: 96 instead of 16

 165  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:36.930 2009  to  Mon Aug 31 21:34:36.930 2009   (  0.00) secs
                     right PMC Actuator 240 set force bad return: 10 instead of 11

 166  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:37.284 2009  to  Mon Aug 31 21:34:37.284 2009   (  0.00) secs
                     right PMC Actuator 311 set force bad return: 20 instead of 11

 167  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:37.637 2009  to  Mon Aug 31 21:34:37.637 2009   (  0.00) secs
                     right PMC Actuator 307 set force read error: -3

 168  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:39.825 2009  to  Mon Aug 31 21:34:39.825 2009   (  0.00) secs
                     right PMC Actuator 325 set force bad return: 21 instead of 14

 169  FAILED    PMC        actuator.setForce.addressError                                Mon Aug 31 21:34:52.687 2009  to  Mon Aug 31 21:34:52.687 2009   (  0.00) secs
                     right PMC Actuator 329 set force bad return: 237 instead of 15

 170  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:53.497 2009  to  Mon Aug 31 21:34:53.497 2009   (  0.00) secs
                     right PMC Actuator 417 set force read error: -3

 171  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:34:54.652 2009  to  Mon Aug 31 21:34:54.652 2009   (  0.00) secs
                     right PMC Actuator 425 set force read error: -3

 172  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:35:30.209 2009  to  Mon Aug 31 21:35:30.209 2009   (  0.00) secs
                     right PMC Actuator 428 set force read error: -3

 173  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:35.726 2009  to  Mon Aug 31 21:35:35.726 2009   (  0.00) secs
                     right PMC Actuator 307 get force read error: -3

 174  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:37.796 2009  to  Mon Aug 31 21:35:37.796 2009   (  0.00) secs
                     right PMC Actuator 410 get force read error: -3

 175  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:35:38.402 2009  to  Mon Aug 31 21:35:38.402 2009   (  0.00) secs
                     right PMC Actuator 435 get force read error: -3

 176  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:01.159 2009  to  Mon Aug 31 21:37:01.159 2009   (  0.00) secs
                     right PMC Actuator 109 set force read error: -3

 177  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:03.440 2009  to  Mon Aug 31 21:37:03.440 2009   (  0.00) secs
                     right PMC Actuator 137 set force read error: -3

 178  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:04.001 2009  to  Mon Aug 31 21:37:04.001 2009   (  0.00) secs
                     right PMC Actuator 231 set force read error: -3

 179  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:12.307 2009  to  Mon Aug 31 21:37:12.307 2009   (  0.00) secs
                     right PMC Actuator 328 set force read error: -3

 180  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:18.287 2009  to  Mon Aug 31 21:37:18.287 2009   (  0.00) secs
                     right PMC Actuator 239 get force read error: -3

 181  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:18.337 2009  to  Mon Aug 31 21:37:18.337 2009   (  0.00) secs
                     right PMC Actuator 131 set force read error: -3

 182  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:20.507 2009  to  Mon Aug 31 21:37:20.507 2009   (  0.00) secs
                     right PMC Actuator 327 get force read error: -3

 183  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:20.810 2009  to  Mon Aug 31 21:37:20.810 2009   (  0.00) secs
                     right PMC Actuator 101 set force read error: -3

 184  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:22.134 2009  to  Mon Aug 31 21:37:22.134 2009   (  0.00) secs
                     right PMC Actuator 106 set force read error: -3

 185  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:23.458 2009  to  Mon Aug 31 21:37:23.458 2009   (  0.00) secs
                     right PMC Actuator 114 set force read error: -3

 186  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:24.116 2009  to  Mon Aug 31 21:37:24.116 2009   (  0.00) secs
                     right PMC Actuator 438 get force read error: -3

 187  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:27.975 2009  to  Mon Aug 31 21:37:27.975 2009   (  0.00) secs
                     right PMC Actuator 304 set force read error: -3

 188  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:28.026 2009  to  Mon Aug 31 21:37:28.026 2009   (  0.00) secs
                     right PMC Actuator 306 set force read error: -3

 189  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:38.191 2009  to  Mon Aug 31 21:37:38.191 2009   (  0.00) secs
                     right PMC Actuator 229 get force read error: -3

 190  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:40.313 2009  to  Mon Aug 31 21:37:40.313 2009   (  0.00) secs
                     right PMC Actuator 310 get force read error: -3

 191  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:45.429 2009  to  Mon Aug 31 21:37:45.429 2009   (  0.00) secs
                     right PMC Actuator 343 get force read error: -3

 192  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:37:46.204 2009  to  Mon Aug 31 21:37:46.204 2009   (  0.00) secs
                     right PMC Actuator 341 get force read error: -3

 193  FAILED    PMC        actuator.setForce.readError                                   Mon Aug 31 21:37:48.628 2009  to  Mon Aug 31 21:37:48.628 2009   (  0.00) secs
                     right PMC Actuator 107 set force read error: -3

 194  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:43.487 2009  to  Mon Aug 31 21:47:43.487 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 195  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:44.040 2009  to  Mon Aug 31 21:47:44.040 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 196  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:45.192 2009  to  Mon Aug 31 21:47:45.192 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 197  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:46.002 2009  to  Mon Aug 31 21:47:46.002 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 198  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:47.065 2009  to  Mon Aug 31 21:47:47.065 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 199  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:48.179 2009  to  Mon Aug 31 21:47:48.179 2009   (  0.00) secs
                     right PMC Hardpoint 5 get data time out

 200  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:49.241 2009  to  Mon Aug 31 21:47:49.241 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 201  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:50.050 2009  to  Mon Aug 31 21:47:50.050 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 202  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:51.191 2009  to  Mon Aug 31 21:47:51.191 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 203  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:52.250 2009  to  Mon Aug 31 21:47:52.250 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 204  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:53.107 2009  to  Mon Aug 31 21:47:53.107 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 205  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:54.216 2009  to  Mon Aug 31 21:47:54.216 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 206  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:55.023 2009  to  Mon Aug 31 21:47:55.023 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 207  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:56.132 2009  to  Mon Aug 31 21:47:56.132 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 208  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:57.192 2009  to  Mon Aug 31 21:47:57.192 2009   (  0.00) secs
                     right PMC Hardpoint 1 get data time out

 209  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:58.047 2009  to  Mon Aug 31 21:47:58.047 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 210  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:47:59.106 2009  to  Mon Aug 31 21:47:59.106 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 211  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:47:59.662 2009  to  Mon Aug 31 21:47:59.662 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 212  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:47:59.713 2009  to  Mon Aug 31 21:47:59.713 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 213  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:47:59.763 2009  to  Mon Aug 31 21:47:59.763 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 214  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:47:59.814 2009  to  Mon Aug 31 21:47:59.814 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 215  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:00.117 2009  to  Mon Aug 31 21:48:00.117 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 216  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:01.012 2009  to  Mon Aug 31 21:48:01.012 2009   (  0.00) secs
                     right PMC Hardpoint 5 get data time out

 217  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:02.072 2009  to  Mon Aug 31 21:48:02.072 2009   (  0.00) secs
                     right PMC Hardpoint 3 get data time out

 218  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:03.133 2009  to  Mon Aug 31 21:48:03.133 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 219  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:04.240 2009  to  Mon Aug 31 21:48:04.240 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 220  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:05.045 2009  to  Mon Aug 31 21:48:05.045 2009   (  0.00) secs
                     right PMC Hardpoint 4 get data time out

 221  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:06.200 2009  to  Mon Aug 31 21:48:06.200 2009   (  0.00) secs
                     right PMC Hardpoint 2 get data time out

 222  FAILED    PMC        hardPoint.getData.timeout                                     Mon Aug 31 21:48:07.008 2009  to  Mon Aug 31 21:48:07.008 2009   (  0.00) secs
                     right PMC Hardpoint 0 get data time out

 223  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:48:25.385 2009  to  Mon Aug 31 21:48:25.385 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 224  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:48:25.486 2009  to  Mon Aug 31 21:48:25.486 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 225  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:48:25.435 2009  to  Mon Aug 31 21:48:25.435 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 226  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:48:25.536 2009  to  Mon Aug 31 21:48:25.536 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 227  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:48:51.072 2009  to  Mon Aug 31 21:48:51.072 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 228  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:48:51.376 2009  to  Mon Aug 31 21:48:51.376 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 229  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:48:51.427 2009  to  Mon Aug 31 21:48:51.427 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 230  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:48:51.478 2009  to  Mon Aug 31 21:48:51.478 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 231  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:49:16.811 2009  to  Mon Aug 31 21:49:16.811 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 232  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:49:16.862 2009  to  Mon Aug 31 21:49:16.862 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 233  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:49:17.164 2009  to  Mon Aug 31 21:49:17.164 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 234  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:49:17.266 2009  to  Mon Aug 31 21:49:17.266 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 235  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:49:42.554 2009  to  Mon Aug 31 21:49:42.554 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 236  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:49:42.605 2009  to  Mon Aug 31 21:49:42.605 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 237  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:49:42.906 2009  to  Mon Aug 31 21:49:42.906 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 238  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:49:42.957 2009  to  Mon Aug 31 21:49:42.957 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 239  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:50:08.530 2009  to  Mon Aug 31 21:50:08.530 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 240  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:50:08.631 2009  to  Mon Aug 31 21:50:08.631 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 241  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:50:08.581 2009  to  Mon Aug 31 21:50:08.581 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 242  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:50:08.681 2009  to  Mon Aug 31 21:50:08.681 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 243  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:50:34.301 2009  to  Mon Aug 31 21:50:34.301 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 244  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:50:34.404 2009  to  Mon Aug 31 21:50:34.404 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 245  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:50:34.353 2009  to  Mon Aug 31 21:50:34.353 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 246  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:50:34.455 2009  to  Mon Aug 31 21:50:34.455 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 247  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:00.052 2009  to  Mon Aug 31 21:51:00.052 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 248  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:00.001 2009  to  Mon Aug 31 21:51:00.001 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 249  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:00.157 2009  to  Mon Aug 31 21:51:00.157 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 250  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:00.209 2009  to  Mon Aug 31 21:51:00.209 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 251  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:25.807 2009  to  Mon Aug 31 21:51:25.807 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 252  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:25.756 2009  to  Mon Aug 31 21:51:25.756 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 253  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:25.858 2009  to  Mon Aug 31 21:51:25.858 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 254  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:25.909 2009  to  Mon Aug 31 21:51:25.909 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 255  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:51:51.432 2009  to  Mon Aug 31 21:51:51.432 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 256  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:51:51.556 2009  to  Mon Aug 31 21:51:51.556 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 257  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:51:51.505 2009  to  Mon Aug 31 21:51:51.505 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 258  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:51:51.607 2009  to  Mon Aug 31 21:51:51.607 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 259  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:52:17.183 2009  to  Mon Aug 31 21:52:17.183 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 260  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:52:17.285 2009  to  Mon Aug 31 21:52:17.285 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 261  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:52:17.234 2009  to  Mon Aug 31 21:52:17.234 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 262  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:52:17.587 2009  to  Mon Aug 31 21:52:17.587 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 263  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:52:42.971 2009  to  Mon Aug 31 21:52:42.971 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 264  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:52:42.920 2009  to  Mon Aug 31 21:52:42.920 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 265  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:52:43.023 2009  to  Mon Aug 31 21:52:43.023 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 266  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:52:43.379 2009  to  Mon Aug 31 21:52:43.379 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 267  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:53:08.699 2009  to  Mon Aug 31 21:53:08.699 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 268  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:53:08.801 2009  to  Mon Aug 31 21:53:08.801 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 269  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:53:08.750 2009  to  Mon Aug 31 21:53:08.750 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 270  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:53:09.105 2009  to  Mon Aug 31 21:53:09.105 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 271  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:53:34.542 2009  to  Mon Aug 31 21:53:34.542 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 272  FAILED    PMC        voltageMonitor.plus7.failed                                   Mon Aug 31 21:53:34.491 2009  to  Mon Aug 31 21:53:34.491 2009   (  0.00) secs
                     right PMC 7 volt failure: 2.95 V, requirement is 6.75

 273  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:53:34.593 2009  to  Mon Aug 31 21:53:34.593 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 274  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:53:34.643 2009  to  Mon Aug 31 21:53:34.643 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 275  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:00.268 2009  to  Mon Aug 31 21:54:00.268 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 276  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:00.319 2009  to  Mon Aug 31 21:54:00.319 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 277  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:00.622 2009  to  Mon Aug 31 21:54:00.622 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 278  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:25.968 2009  to  Mon Aug 31 21:54:25.968 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 279  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:26.271 2009  to  Mon Aug 31 21:54:26.271 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 280  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:26.373 2009  to  Mon Aug 31 21:54:26.373 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 281  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:54:51.946 2009  to  Mon Aug 31 21:54:51.946 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 282  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:54:51.997 2009  to  Mon Aug 31 21:54:51.997 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 283  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:54:52.100 2009  to  Mon Aug 31 21:54:52.100 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 284  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:55:17.691 2009  to  Mon Aug 31 21:55:17.691 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 285  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:55:17.794 2009  to  Mon Aug 31 21:55:17.794 2009   (  0.00) secs
                     right PMC -15 volt failure: -0.00 V, requirement is -14.00

 286  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:55:17.844 2009  to  Mon Aug 31 21:55:17.844 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 287  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:55:43.266 2009  to  Mon Aug 31 21:55:43.266 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 288  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:55:43.569 2009  to  Mon Aug 31 21:55:43.569 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 289  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:55:43.619 2009  to  Mon Aug 31 21:55:43.619 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.06 V, requirement is 14.00

 290  FAILED    PMC        voltageMonitor.plus15.failed                                  Mon Aug 31 21:56:09.193 2009  to  Mon Aug 31 21:56:09.193 2009   (  0.00) secs
                     right PMC +15 volt failure: 0.00 V, requirement is 14.00

 291  FAILED    PMC        voltageMonitor.minus15.failed                                 Mon Aug 31 21:56:09.243 2009  to  Mon Aug 31 21:56:09.243 2009   (  0.00) secs
                     right PMC -15 volt failure: 0.00 V, requirement is -14.00

 292  FAILED    PMC        voltageMonitor.plus20.failed                                  Mon Aug 31 21:56:09.343 2009  to  Mon Aug 31 21:56:09.343 2009   (  0.00) secs
                     right PMC 20 volt failure: 5.14 V, requirement is 14.00

 293  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:15.455 2009  to  Mon Aug 31 21:56:15.455 2009   (  0.00) secs
                     right PMC Actuator 127 get force read error: -3

 294  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:17.322 2009  to  Mon Aug 31 21:56:17.322 2009   (  0.00) secs
                     right PMC Actuator 215 get force read error: -3

 295  FAILED    PMC        actuator.getForce.readError                                   Mon Aug 31 21:56:19.323 2009  to  Mon Aug 31 21:56:19.323 2009   (  0.00) secs
                     right PMC Actuator 303 get force read error: -3

 296  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 21:57:44.575 2009  to  Mon Aug 31 21:57:44.575 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

 297  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 21:58:03.306 2009  to  Mon Aug 31 21:58:03.306 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

 298  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 22:01:55.894 2009  to  Mon Aug 31 22:01:55.894 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

 299  FAILED    PMC        command.recoverPanic                                          Mon Aug 31 22:30:07.359 2009  to  Mon Aug 31 22:30:12.411 2009   (  5.05) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 300  FAILED    PMC        mirror.panic                                                  Mon Aug 31 22:30:07.651 2009  to  Mon Aug 31 22:30:07.651 2009   (  0.00) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 301  FAILED    PMC        command.recoverPanic                                          Mon Aug 31 22:50:38.645 2009  to  Mon Aug 31 22:50:43.699 2009   (  5.05) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 302  FAILED    PMC        mirror.panic                                                  Mon Aug 31 22:50:38.891 2009  to  Mon Aug 31 22:50:38.891 2009   (  0.00) secs
                     right PMC ** PANIC: Outer loop stalled
                     right PMC RecoverPanic Command Failed because Recover PANIC failed to complete

 303  STARTUP   PMC        startup                                                       Mon Aug 31 22:54:26.407 2009  to  Mon Aug 31 22:54:26.407 2009   (  0.00) secs
                     right PMC subsystem started, version 5.0

 304  FAILED    PMC        telemetryError                                                Mon Aug 31 22:54:26.460 2009  to  Mon Aug 31 22:54:26.460 2009   (  0.00) secs
                     right PMC telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 305  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 22:54:35.688 2009  to  Mon Aug 31 22:54:35.688 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: This singleton has not been initialized

 306  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 22:54:35.790 2009  to  Mon Aug 31 22:54:35.790 2009   (  0.00) secs
                     right PMC Motor telemetry error: This singleton has not been initialized

 307  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 22:54:35.892 2009  to  Mon Aug 31 22:54:35.892 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: This singleton has not been initialized

 308  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 22:54:35.994 2009  to  Mon Aug 31 22:54:35.994 2009   (  0.00) secs
                     right PMC Mirror telemetry error: This singleton has not been initialized

 309  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 22:54:36.147 2009  to  Mon Aug 31 22:54:36.147 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: This singleton has not been initialized

 310  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 22:54:37.404 2009  to  Mon Aug 31 22:54:37.404 2009   (  0.00) secs
                     right PMC Thermal telemetry error: This singleton has not been initialized

 311  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 22:54:37.505 2009  to  Mon Aug 31 22:54:37.505 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: This singleton has not been initialized

 312  FAILED    PMC        servoLoop.telemetryError                                      Mon Aug 31 22:54:38.922 2009  to  Mon Aug 31 22:54:38.922 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 313  FAILED    PMC        hardPoint.telemetryError                                      Mon Aug 31 22:54:38.991 2009  to  Mon Aug 31 22:54:38.991 2009   (  0.00) secs
                     right PMC Hardpoint telemetry error: No telemetry since telemeter registration failed.

 314  FAILED    PMC        mirror.telemetryError                                         Mon Aug 31 22:54:39.017 2009  to  Mon Aug 31 22:54:39.017 2009   (  0.00) secs
                     right PMC Mirror telemetry error: No telemetry since telemeter registration failed.

 315  FAILED    PMC        airPressure.telemetryError                                    Mon Aug 31 22:54:39.099 2009  to  Mon Aug 31 22:54:39.099 2009   (  0.00) secs
                     right PMC AirPressure telemetry error: No telemetry since telemeter registration failed.

 316  FAILED    PMC        motor.telemetryError                                          Mon Aug 31 22:54:39.086 2009  to  Mon Aug 31 22:54:39.086 2009   (  0.00) secs
                     right PMC Motor telemetry error: No telemetry since telemeter registration failed.

 317  FAILED    PMC        cellStatus.telemetryError                                     Mon Aug 31 22:54:39.178 2009  to  Mon Aug 31 22:54:39.178 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: No telemetry since telemeter registration failed.

 318  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Aug 31 22:55:13.604 2009  to  Mon Aug 31 22:55:13.604 2009   (  0.00) secs
                     right PMC Actuator 429 force monitor 1 PANIC! 159.1 lbs, limit is 0.0

 319  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Aug 31 22:55:25.881 2009  to  Mon Aug 31 22:55:25.881 2009   (  0.00) secs
                     right PMC Actuator 234 force monitor 1 PANIC! -169.2 lbs, limit is 0.0

 320  FAILED    PMC        thermal.telemetryError                                        Mon Aug 31 22:55:27.882 2009  to  Mon Aug 31 22:55:27.882 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 321  SEQERROR  IIF        command.getMultiDDEntry                                       Mon Aug 31 23:01:31.197 2009  to  Mon Aug 31 23:01:31.197 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left IRTC

 322  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:45.622 2009  to  Tue Sep  1 02:27:52.717 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LBC at prime focus

 323  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:45.624 2009  to  Tue Sep  1 02:27:52.719 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 324  SEQERROR  OSS        side[1].terc.movefocalstation.command                         Tue Sep  1 02:27:46.374 2009  to  Tue Sep  1 05:22:32.854 2009   (  0.00) secs
                    Started event but no Complete event
                     side[1].terc: [moveFocalStation] command.started

 325  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 02:27:46.729 2009  to  Tue Sep  1 05:22:33.003 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

 326  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:52.717 2009  to  Tue Sep  1 02:27:53.703 2009   (  0.99) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LBC at prime focus

 327  FAILED    PCS        telescope.command.stopTracking                                Tue Sep  1 02:27:52.776 2009  to  Tue Sep  1 02:27:52.883 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 328  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 02:27:52.719 2009  to  Tue Sep  1 02:27:53.481 2009   (  0.76) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 329  FAILED    PCS        telescope.command.stopTracking                                Tue Sep  1 02:27:52.884 2009  to  Tue Sep  1 02:27:52.992 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 330  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Sep  1 02:30:00.148 2009  to  Tue Sep  1 02:30:00.202 2009   (  0.05) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 331  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Sep  1 02:30:07.603 2009  to  Tue Sep  1 02:30:07.655 2009   (  0.05) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 332  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:04:12.652 2009  to  Tue Sep  1 03:05:24.760 2009   ( 72.11) secs
                     IIF GetTrajectory command started for both LBC, start time 5.507512793981482e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

 333  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 03:04:13.161 2009  to  Tue Sep  1 03:04:13.161 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

 334  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Sep  1 03:04:50.044 2009  to  Tue Sep  1 03:05:22.461 2009   ( 32.42) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 335  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Sep  1 03:04:50.099 2009  to  Tue Sep  1 03:05:22.401 2009   ( 32.30) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 336  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:05:51.680 2009  to  Tue Sep  1 03:06:01.080 2009   (  9.40) secs
                     IIF GetTrajectory command started for both LBC, start time 5.507512908564815e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

 337  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Sep  1 03:05:54.408 2009  to  Tue Sep  1 03:06:00.785 2009   (  6.38) secs
                     right PSF primary mirror adjustMirrorCollimation started with argument 0.0000000e+00
                     left PSF primary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 338  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Sep  1 03:05:54.463 2009  to  Tue Sep  1 03:06:00.724 2009   (  6.26) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 339  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 03:06:21.860 2009  to  Tue Sep  1 03:06:23.114 2009   (  1.25) secs
                     IIF Preset command started for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

 340  SEQERROR  PCS        telescope.command.startTracking                               Tue Sep  1 03:06:22.392 2009  to  Tue Sep  1 04:49:32.433 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

 341  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:13:17.349 2009  to  Tue Sep  1 03:13:17.349 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 342  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:13:17.349 2009  to  Tue Sep  1 03:13:17.349 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 343  STARTUP   PCS        startup                                                       Tue Sep  1 03:13:25.398 2009  to  Tue Sep  1 03:13:25.398 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 4.1

 344  FAILED    PCS        telemetryError                                                Tue Sep  1 03:13:25.465 2009  to  Tue Sep  1 03:13:25.465 2009   (  0.00) secs
                     PCS telemetry error: 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 345  FAILED    PCS        guider.telemetryError                                         Tue Sep  1 03:13:25.574 2009  to  Tue Sep  1 03:13:25.574 2009   (  0.00) secs
                     PCS Guider telemetry error: This singleton has not been initialized

 346  FAILED    PCS        weather.telemetryError                                        Tue Sep  1 03:13:25.628 2009  to  Tue Sep  1 03:13:25.628 2009   (  0.00) secs
                     PCS Weather telemetry error: This singleton has not been initialized

 347  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 03:13:25.680 2009  to  Tue Sep  1 03:13:25.680 2009   (  0.00) secs
                     PCS Telescope telemetry error: This singleton has not been initialized

 348  FAILED    PCS        weather.telemetryError                                        Tue Sep  1 03:13:25.736 2009  to  Tue Sep  1 03:13:25.736 2009   (  0.00) secs
                     PCS Weather telemetry error: No telemetry since telemeter registration failed.

 349  FAILED    OSS        side[0].swa                                                   Tue Sep  1 03:28:39.737 2009  to  Tue Sep  1 03:28:39.737 2009   (  0.00) secs
                     side[0].swa: MCSPU not connected

 350  FAILED    OSS        side[1].swa                                                   Tue Sep  1 03:28:39.735 2009  to  Tue Sep  1 03:28:39.735 2009   (  0.00) secs
                     side[1].swa: MCSPU not connected

 351  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:29:35.223 2009  to  Tue Sep  1 03:29:35.223 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 352  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 03:29:35.227 2009  to  Tue Sep  1 03:29:35.227 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 353  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Sep  1 03:29:35.331 2009  to  Tue Sep  1 03:29:35.331 2009   (  0.00) secs
                     drive cabinet has turned on.

 354  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.335 2009  to  Tue Sep  1 03:29:36.335 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 355  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.335 2009  to  Tue Sep  1 03:29:36.335 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 356  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.336 2009  to  Tue Sep  1 03:29:36.336 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 357  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.336 2009  to  Tue Sep  1 03:29:36.336 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 358  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.363 2009  to  Tue Sep  1 03:29:36.363 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 359  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.364 2009  to  Tue Sep  1 03:29:36.364 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 360  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.365 2009  to  Tue Sep  1 03:29:36.365 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 361  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Sep  1 03:29:36.365 2009  to  Tue Sep  1 03:29:36.365 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 362  FAILED    OSS        side[0].swa                                                   Tue Sep  1 03:29:39.836 2009  to  Tue Sep  1 03:29:39.836 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

 363  FAILED    OSS        side[1].swa                                                   Tue Sep  1 03:29:39.823 2009  to  Tue Sep  1 03:29:39.823 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

 364  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Sep  1 03:30:40.102 2009  to  Tue Sep  1 03:30:40.102 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 365  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Sep  1 03:31:02.871 2009  to  Tue Sep  1 03:31:02.871 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 366  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.614 2009  to  Tue Sep  1 03:32:09.614 2009   (  0.00) secs
                     2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 367  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.665 2009  to  Tue Sep  1 03:32:09.665 2009   (  0.00) secs
                     This singleton has not been initialized

 368  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.716 2009  to  Tue Sep  1 03:32:09.716 2009   (  0.00) secs
                     This singleton has not been initialized

 369  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.766 2009  to  Tue Sep  1 03:32:09.766 2009   (  0.00) secs
                     This singleton has not been initialized

 370  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.816 2009  to  Tue Sep  1 03:32:09.816 2009   (  0.00) secs
                     This singleton has not been initialized

 371  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.866 2009  to  Tue Sep  1 03:32:09.866 2009   (  0.00) secs
                     This singleton has not been initialized

 372  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.915 2009  to  Tue Sep  1 03:32:09.915 2009   (  0.00) secs
                     This singleton has not been initialized

 373  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:09.965 2009  to  Tue Sep  1 03:32:09.965 2009   (  0.00) secs
                     This singleton has not been initialized

 374  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.015 2009  to  Tue Sep  1 03:32:10.015 2009   (  0.00) secs
                     This singleton has not been initialized

 375  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.065 2009  to  Tue Sep  1 03:32:10.065 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_left: This singleton has not been initialized

 376  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.115 2009  to  Tue Sep  1 03:32:10.115 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_left: This singleton has not been initialized

 377  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.165 2009  to  Tue Sep  1 03:32:10.165 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_left: This singleton has not been initialized

 378  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.215 2009  to  Tue Sep  1 03:32:10.215 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_left: This singleton has not been initialized

 379  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.265 2009  to  Tue Sep  1 03:32:10.265 2009   (  0.00) secs
                     Error making Hyd. lat_pad1_right: This singleton has not been initialized

 380  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.315 2009  to  Tue Sep  1 03:32:10.315 2009   (  0.00) secs
                     Error making Hyd. lat_pad2_right: This singleton has not been initialized

 381  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.365 2009  to  Tue Sep  1 03:32:10.365 2009   (  0.00) secs
                     Error making Hyd. lat_pad3_right: This singleton has not been initialized

 382  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.415 2009  to  Tue Sep  1 03:32:10.415 2009   (  0.00) secs
                     Error making Hyd. lat_pad4_right: This singleton has not been initialized

 383  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.465 2009  to  Tue Sep  1 03:32:10.465 2009   (  0.00) secs
                     hbs sys params.variables:This singleton has not been initialized

 384  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.515 2009  to  Tue Sep  1 03:32:10.515 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

 385  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.error                                Tue Sep  1 03:32:10.565 2009  to  Tue Sep  1 03:32:10.565 2009   (  0.00) secs
                     Error making Hyd. bearing measure: This singleton has not been initialized

 386  FAILED    PCS        telescope.telemetryError                                      Tue Sep  1 04:49:32.319 2009  to  Tue Sep  1 04:49:32.319 2009   (  0.00) secs
                     PCS Telescope telemetry error: No telemetry since telemeter registration failed.

 387  FAILED    PMC        VxInterface.lengthError                                       Tue Sep  1 05:04:18.562 2009  to  Tue Sep  1 05:04:18.562 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 388  FAILED    PMC        VxInterface.close                                             Tue Sep  1 05:04:18.613 2009  to  Tue Sep  1 05:04:18.613 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 389  SEQERROR  PCS        telescope.command.stopTracking                                Tue Sep  1 05:22:32.069 2009  to  Tue Sep  1 05:22:32.174 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 390  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:22:32.007 2009  to  Tue Sep  1 05:34:32.962 2009   (720.96) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

 391  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:22:32.009 2009  to  Tue Sep  1 05:34:28.146 2009   (716.14) secs
                     IIF TCS authorize command started for right IRTC at bentGregorianFront focus
                     IIF TCS authorize alert for right IRTC at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for right IRTC at bentGregorianFront focus

 392  SEQERROR  PCS        telescope.command.stopTracking                                Tue Sep  1 05:22:32.279 2009  to  Tue Sep  1 05:22:32.279 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 393  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 05:22:33.003 2009  to  Tue Sep  1 05:31:20.132 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

 394  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 05:22:33.167 2009  to  Tue Sep  1 05:22:33.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 395  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Sep  1 05:22:33.208 2009  to  Tue Sep  1 05:22:33.208 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 396  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:24:22.506 2009  to  Tue Sep  1 05:24:24.294 2009   (  1.79) secs
                     IIF Preset command started for left IRTC mode TRACK from IIF
                     IIF Preset alert for left IRTC mode TRACK: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode TRACK from IIF

 397  FAILED    PCS        telescope.command.startTracking                               Tue Sep  1 05:24:23.264 2009  to  Tue Sep  1 05:24:24.088 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

 398  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:25:27.265 2009  to  Tue Sep  1 05:34:28.320 2009   (541.05) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset alert for left IRTC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode TRACK from IIF

 399  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:25:45.937 2009  to  Tue Sep  1 05:25:46.121 2009   (  0.18) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

 400  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Sep  1 05:25:45.947 2009  to  Tue Sep  1 05:34:28.042 2009   (522.10) secs
                     left PSF tertiary mirror adjustMirrorCollimation failed for rzColl 0 with argument 0.0000000e+00 because Invalid buffer: RPCERROR

 401  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:25:46.016 2009  to  Tue Sep  1 05:43:02.851 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

 402  SEQERROR  OSS        side[0].terc.adjustcurrfocalstation.command                   Tue Sep  1 05:25:46.018 2009  to  Tue Sep  1 05:43:02.854 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [adjustCurrFocalStation] command.started

 403  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:25:46.066 2009  to  Tue Sep  1 05:25:46.066 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

 404  SEQERROR  OSS        side[0].terc.movefocalstation.command                         Tue Sep  1 05:31:20.132 2009  to  Tue Sep  1 05:47:38.669 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].terc: [moveFocalStation] command.started

 405  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:34:28.147 2009  to  Tue Sep  1 05:34:28.147 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

 406  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Sep  1 05:34:33.331 2009  to  Tue Sep  1 05:34:33.331 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

 407  STARTUP   OSS        startup                                                       Tue Sep  1 05:34:53.207 2009  to  Tue Sep  1 05:34:53.207 2009   (  0.00) secs
                     The oss was started.

 408  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 05:34:56.810 2009  to  Tue Sep  1 05:34:56.810 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 409  FAILED    OSS        side[0].swa                                                   Tue Sep  1 05:34:57.312 2009  to  Tue Sep  1 05:34:57.312 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

 410  FAILED    OSS        side[1].swa                                                   Tue Sep  1 05:34:57.815 2009  to  Tue Sep  1 05:34:57.815 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

 411  SHUTDOWN  OSS        shutdown                                                      Tue Sep  1 05:37:36.633 2009  to  Tue Sep  1 05:37:36.633 2009   (  0.00) secs
                     The oss was shut down.

 412  STARTUP   OSS        startup                                                       Tue Sep  1 05:38:30.775 2009  to  Tue Sep  1 05:38:30.775 2009   (  0.00) secs
                     The oss was started.

 413  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 05:38:34.345 2009  to  Tue Sep  1 05:38:34.345 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 414  FAILED    OSS        side[0].swa                                                   Tue Sep  1 05:38:34.849 2009  to  Tue Sep  1 05:38:34.849 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

 415  FAILED    OSS        side[1].swa                                                   Tue Sep  1 05:38:35.350 2009  to  Tue Sep  1 05:38:35.350 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

 416  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:42:52.340 2009  to  Tue Sep  1 05:43:06.117 2009   ( 13.78) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode TRACK from IIF

 417  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:43:02.604 2009  to  Tue Sep  1 05:43:02.959 2009   (  0.36) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

 418  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:43:02.851 2009  to  Tue Sep  1 05:53:00.178 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

 419  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:43:02.903 2009  to  Tue Sep  1 05:43:02.903 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

 420  FAILED    IIF        command.preset.(TRACK)                                        Tue Sep  1 05:52:51.598 2009  to  Tue Sep  1 05:53:03.572 2009   ( 11.97) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode TRACK: side[0].adsc: [moveAbs] Move would go outside limits
                     IIF Preset command failed for left IRTC mode TRACK from IIF

 421  FAILED    PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Sep  1 05:53:00.120 2009  to  Tue Sep  1 05:53:00.285 2009   (  0.16) secs
                     left PSF tertiary mirror adjustMirrorCollimation started for rzColl 0 with argument 0.0000000e+00
                     left PSF secondary mirror adjustMirrorCollimation failed with argument 0.0000000e+00 because side[0].adsc: [moveAbs] Move would go outside limits

 422  SEQERROR  OSS        side[0].adsc.moveabs.command                                  Tue Sep  1 05:53:00.178 2009  to  Tue Sep  1 06:06:00.747 2009   (  0.00) secs
                    Started event but no Complete event
                     side[0].adsc: [moveAbs] command.started

 423  FAILED    OSS        side[0].adsc.moveabs.failed                                   Tue Sep  1 05:53:00.229 2009  to  Tue Sep  1 05:53:00.229 2009   (  0.00) secs
                     side[0].adsc: [moveAbs] Move would go outside limits

 424  SHUTDOWN  OSS        shutdown                                                      Tue Sep  1 06:01:41.399 2009  to  Tue Sep  1 06:01:41.399 2009   (  0.00) secs
                     The oss was shut down.

 425  STARTUP   OSS        startup                                                       Tue Sep  1 06:02:05.103 2009  to  Tue Sep  1 06:02:05.103 2009   (  0.00) secs
                     The oss was started.

 426  FAILED    OSS        inittel.store_client_error                                    Tue Sep  1 06:02:08.671 2009  to  Tue Sep  1 06:02:08.671 2009   (  0.00) secs
                     [initTel] 2002: Can''t connect to local MySQL server through socket ''/var/lib/mysql/mysql.sock'' (2)

 427  FAILED    OSS        side[0].swa                                                   Tue Sep  1 06:02:09.173 2009  to  Tue Sep  1 06:02:09.173 2009   (  0.00) secs
                     side[0].swa: Interlock Faulted

 428  FAILED    OSS        side[1].swa                                                   Tue Sep  1 06:02:09.676 2009  to  Tue Sep  1 06:02:09.676 2009   (  0.00) secs
                     side[1].swa: Interlock Faulted

**********************************************************
    Reporting period ending:   Tue Sep  1 06:24:59.606 2009
********************************************************************************************************