You are here: Foswiki>Software Web>TCSSWReportFile_090614 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jun 14 2009 to Jun 15 2009
 
    Reporting period beginning:   Sun Jun 14 18:58:00.772 2009
    Reporting period ending:      Mon Jun 15 04:49:50.720 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.36    0.67    0.38    1.16    50.0 %          4          2          2           
                                                                       0.23    0.54    0.38    0.70

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Jun 15 01:16:18.089 2009  to  Mon Jun 15 01:16:19.253 2009   (  1.16) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Jun 15 01:16:18.093 2009  to  Mon Jun 15 01:16:18.507 2009   (  0.41) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.10   100.0 %         53         53                      
                                                                       0.01    0.05    0.05    0.10
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.02    0.22    0.20    0.36   100.0 %         86         86                      
                                                                       0.02    0.22    0.20    0.36
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    8.04    7.31    0.58   55.57    93.2 %        132        123          9           
                                                                       8.21    7.67    2.47   55.57
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   23.05   16.78    0.00   50.86    50.0 %          4          2          2           
                                                                       0.00    7.49    7.49    7.49
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   36.74   27.70    1.25   79.17   100.0 %          4          4                      
                                                                      36.74   27.70    1.25   79.17
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.00    2.07    2.07    2.07   100.0 %          2          2                      
                                                                       0.00    2.07    2.07    2.07
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    5.23   11.33    4.08   29.84    88.5 %         52         46          6           
                                                                       5.10   11.81    5.12   29.84
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    0.00    4.49    4.49    4.49   100.0 %          2          2                      
                                                                       0.00    4.49    4.49    4.49

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jun 15 03:56:07.372 2009  to  Mon Jun 15 03:58:00.994 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

   2  FAILED    IIF        command.preset.(TRACK)                                        Mon Jun 15 03:58:00.994 2009  to  Mon Jun 15 03:58:09.775 2009   (  8.78) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

   3  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jun 15 03:58:36.530 2009  to  Mon Jun 15 03:58:36.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

   4  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:23:07.919 2009  to  Mon Jun 15 04:23:25.963 2009   ( 18.04) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   5  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:23:28.084 2009  to  Mon Jun 15 04:23:33.109 2009   (  5.02) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

   6  FAILED    IIF        command.preset.(TRACK)                                        Mon Jun 15 04:26:57.147 2009  to  Mon Jun 15 04:27:48.007 2009   ( 50.86) secs
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

   7  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:27:31.396 2009  to  Mon Jun 15 04:27:35.473 2009   (  4.08) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

   8  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:43:16.471 2009  to  Mon Jun 15 04:43:23.626 2009   (  7.15) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

   9  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:46:06.303 2009  to  Mon Jun 15 04:46:08.890 2009   (  2.59) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719868055556e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -1.000000000000000e-01

  10  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:46:41.474 2009  to  Mon Jun 15 04:46:44.062 2009   (  2.59) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719908564815e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -2.000000000000000e-02

  11  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:47:36.307 2009  to  Mon Jun 15 04:47:38.926 2009   (  2.62) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719972222222e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-02

  12  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:56:27.673 2009  to  Mon Jun 15 04:56:30.316 2009   (  2.64) secs
                     IIF MoveFocus command started for right LBC for 2.430000000000000e+00
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.430000000000000e+00

  13  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 05:08:43.655 2009  to  Mon Jun 15 05:08:49.363 2009   (  5.71) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

  14  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:14:26.007 2009  to  Mon Jun 15 05:14:28.600 2009   (  2.59) secs
                     IIF MoveFocus command started for right LBC for 3.800000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 3.800000000000000e-01

  15  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 05:26:50.285 2009  to  Mon Jun 15 05:26:56.081 2009   (  5.80) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

  16  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:26:56.769 2009  to  Mon Jun 15 05:26:57.352 2009   (  0.58) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  17  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:34:08.045 2009  to  Mon Jun 15 05:34:10.634 2009   (  2.59) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  18  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:36:13.919 2009  to  Mon Jun 15 05:36:16.588 2009   (  2.67) secs
                     IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  19  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:38:13.953 2009  to  Mon Jun 15 05:38:16.549 2009   (  2.60) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3201                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6401                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      23                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          7                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                          
      Nothing to report

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            16
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      27                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      22                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .      33                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest
      Nothing to report
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.00    0.09    0.09    0.10   100.0 %         86         86                      
                                                                       0.00    0.09    0.09    0.10
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.04    0.08    0.05    0.10   100.0 %          2          2                      
                                                                       0.04    0.08    0.05    0.10
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.21    0.65    0.31    0.82   100.0 %          6          6                      
                                                                       0.21    0.65    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.02    0.01    0.00    0.05    50.0 %          4                     2           
                                                                       0.00    0.05    0.05    0.05

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.151 2009  to  Mon Jun 15 01:16:18.210 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.210 2009  to  Mon Jun 15 01:16:18.213 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.294 2009  to  Mon Jun 15 01:16:18.294 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:31.939 2009  to  Mon Jun 15 01:16:31.997 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   5  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:32.102 2009  to  Mon Jun 15 01:16:32.102 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.19    3.00    2.05    8.06   100.0 %         53         53                      
                                                                       1.19    3.00    2.05    8.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.79    3.26    2.05    6.06   100.0 %          5          5                      
                                                                       1.79    3.26    2.05    6.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    9.53    7.26    0.00   89.19    90.6 %        202        183         19           
                                                                       9.84    7.91    2.05   89.19
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            28
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       5                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      53                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           119
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       2                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 01:23:17.645 2009  to  Mon Jun 15 01:23:19.783 2009   (  2.14) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 01:23:26.884 2009  to  Mon Jun 15 01:23:26.934 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   3  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:57:28.132 2009  to  Mon Jun 15 03:58:03.429 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:58:03.429 2009  to  Mon Jun 15 03:58:03.480 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:58:34.284 2009  to  Mon Jun 15 03:58:34.284 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:23:10.562 2009  to  Mon Jun 15 04:23:25.634 2009   ( 15.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:23:30.735 2009  to  Mon Jun 15 04:23:32.790 2009   (  2.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:13.806 2009  to  Mon Jun 15 04:27:27.753 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:27.700 2009  to  Mon Jun 15 04:27:35.105 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:27.753 2009  to  Mon Jun 15 04:27:27.803 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:29.881 2009  to  Mon Jun 15 04:27:29.881 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:35.105 2009  to  Mon Jun 15 04:27:35.156 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  13  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:47.780 2009  to  Mon Jun 15 04:27:47.780 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:43:21.255 2009  to  Mon Jun 15 04:43:23.308 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:46:06.517 2009  to  Mon Jun 15 04:46:08.570 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:46:41.688 2009  to  Mon Jun 15 04:46:43.742 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:47:36.521 2009  to  Mon Jun 15 04:47:38.615 2009   (  2.09) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:56:27.887 2009  to  Mon Jun 15 04:56:29.942 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:08:46.989 2009  to  Mon Jun 15 05:08:49.043 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:14:26.220 2009  to  Mon Jun 15 05:14:28.276 2009   (  2.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PMC        VxInterface.lengthError                                       Mon Jun 15 05:14:28.826 2009  to  Mon Jun 15 05:14:28.826 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Mon Jun 15 05:14:28.876 2009  to  Mon Jun 15 05:14:28.876 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:26:53.710 2009  to  Mon Jun 15 05:26:55.763 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:26:56.984 2009  to  Mon Jun 15 05:26:57.034 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  25  FAILED    PMC        VxInterface.lengthError                                       Mon Jun 15 05:27:40.698 2009  to  Mon Jun 15 05:27:40.698 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Mon Jun 15 05:27:40.748 2009  to  Mon Jun 15 05:27:40.748 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:34:08.260 2009  to  Mon Jun 15 05:34:10.313 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  28  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:36:14.217 2009  to  Mon Jun 15 05:36:16.270 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  29  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:38:14.171 2009  to  Mon Jun 15 05:38:16.226 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    5.24   11.08    3.75   29.62    88.5 %         52         46          6           
                                                                       5.10   11.57    4.91   29.62
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          8          8                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    7.98    7.14    0.37   55.46    93.3 %        134        125          9           
                                                                       8.15    7.50    2.37   55.46
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.23    0.17    0.05    0.52    75.0 %          4          3          1           
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    5.24   11.19    3.91   29.73    88.5 %         52         46          6           
                                                                       5.10   11.68    5.01   29.73
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .   12.55   12.38    3.54   94.89    88.9 %         54         48          6           
                                                                      13.06   13.04    4.70   94.89
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    9.53    7.38    0.00   89.30    90.6 %        202        183         19           
                                                                       9.84    8.04    2.16   89.30
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.79    3.37    2.17    6.18   100.0 %          5          5                      
                                                                       1.79    3.37    2.17    6.18
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.10    0.06    0.19   100.0 %        117        117                      
                                                                       0.04    0.10    0.06    0.19
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.08    0.11    0.05    0.16    50.0 %          2          1          1           
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   10.93   15.56    4.49   27.53    80.0 %          5          4          1           
                                                                      11.21   17.81    4.49   27.53
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    7.98    7.03    0.27   55.35    93.3 %        134        125          9           
                                                                       8.15    7.39    2.27   55.35
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    0.26    0.26    0.26     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.05    0.05    0.11   100.0 %         54         54                      
                                                                       0.01    0.05    0.05    0.11
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.00    0.09    0.09    0.09   100.0 %          1          1                      
                                                                       0.00    0.09    0.09    0.09
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               3701           

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Mon Jun 15 01:16:18.477 2009  to  Mon Jun 15 01:16:18.994 2009   (  0.52) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Mon Jun 15 01:16:18.528 2009  to  Mon Jun 15 01:16:18.688 2009   (  0.16) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.command.revert                                  Mon Jun 15 01:23:13.307 2009  to  Mon Jun 15 01:23:19.890 2009   (  6.58) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 01:23:17.588 2009  to  Mon Jun 15 01:23:19.837 2009   (  2.25) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 01:23:26.829 2009  to  Mon Jun 15 01:23:26.990 2009   (  0.16) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Mon Jun 15 01:23:26.781 2009  to  Mon Jun 15 01:23:27.042 2009   (  0.26) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

   7  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:57:28.074 2009  to  Mon Jun 15 03:58:03.372 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:58:03.372 2009  to  Mon Jun 15 03:58:03.579 2009   (  0.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:58:34.341 2009  to  Mon Jun 15 03:58:34.341 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  10  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:36.704 2009  to  Mon Jun 15 03:58:36.704 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.0469806e-03 1.7477870e-03 -5.6981444e-03 -5.2488327e-02 1.1022186e-01 2.9969215e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:36.957 2009  to  Mon Jun 15 03:58:36.957 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.210 2009  to  Mon Jun 15 03:58:37.210 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  13  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.463 2009  to  Mon Jun 15 03:58:37.463 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  14  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.716 2009  to  Mon Jun 15 03:58:37.716 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  15  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.969 2009  to  Mon Jun 15 03:58:37.969 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5204630e-03 2.0537078e-03 -5.1375031e-03 -4.6501160e-02 9.7423553e-02 2.0063400e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.222 2009  to  Mon Jun 15 03:58:38.222 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.475 2009  to  Mon Jun 15 03:58:38.475 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.728 2009  to  Mon Jun 15 03:58:38.728 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.981 2009  to  Mon Jun 15 03:58:38.981 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.234 2009  to  Mon Jun 15 03:58:39.234 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.487 2009  to  Mon Jun 15 03:58:39.487 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.740 2009  to  Mon Jun 15 03:58:39.740 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.993 2009  to  Mon Jun 15 03:58:39.993 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.246 2009  to  Mon Jun 15 03:58:40.246 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.499 2009  to  Mon Jun 15 03:58:40.499 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.752 2009  to  Mon Jun 15 03:58:40.752 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.005 2009  to  Mon Jun 15 03:58:41.005 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.258 2009  to  Mon Jun 15 03:58:41.258 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.511 2009  to  Mon Jun 15 03:58:41.511 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.764 2009  to  Mon Jun 15 03:58:41.764 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.017 2009  to  Mon Jun 15 03:58:42.017 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.270 2009  to  Mon Jun 15 03:58:42.270 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.4830909e-03 1.3949871e-03 -5.0955415e-03 -6.1143875e-02 1.0244751e-01 4.3019295e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.523 2009  to  Mon Jun 15 03:58:42.523 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.4830909e-03 1.3949871e-03 -5.0955415e-03 -6.1143875e-02 1.0244751e-01 4.3019295e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.776 2009  to  Mon Jun 15 03:58:42.776 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  35  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:23:07.975 2009  to  Mon Jun 15 04:23:25.856 2009   ( 17.88) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  36  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:23:08.025 2009  to  Mon Jun 15 04:23:25.802 2009   ( 17.78) secs
                     right PSF ApplyZernikes failed

  37  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:23:08.181 2009  to  Mon Jun 15 04:23:25.749 2009   ( 17.57) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:23:10.506 2009  to  Mon Jun 15 04:23:25.697 2009   ( 15.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:23:28.195 2009  to  Mon Jun 15 04:23:32.949 2009   (  4.75) secs
                     left PSF ApplyZernikes failed

  40  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:23:28.144 2009  to  Mon Jun 15 04:23:33.003 2009   (  4.86) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  41  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:23:28.352 2009  to  Mon Jun 15 04:23:32.898 2009   (  4.55) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:23:30.677 2009  to  Mon Jun 15 04:23:32.846 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:13.751 2009  to  Mon Jun 15 04:27:27.640 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  44  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:27.640 2009  to  Mon Jun 15 04:27:27.861 2009   (  0.22) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  45  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:27.641 2009  to  Mon Jun 15 04:27:35.049 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  46  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:29.938 2009  to  Mon Jun 15 04:27:29.938 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  47  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:27:31.453 2009  to  Mon Jun 15 04:27:35.367 2009   (  3.91) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  48  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:27:31.565 2009  to  Mon Jun 15 04:27:35.315 2009   (  3.75) secs
                     left PSF ApplyZernikes failed

  49  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:27:31.718 2009  to  Mon Jun 15 04:27:35.263 2009   (  3.54) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:35.049 2009  to  Mon Jun 15 04:27:35.211 2009   (  0.16) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:47.838 2009  to  Mon Jun 15 04:27:47.838 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  52  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:43:16.528 2009  to  Mon Jun 15 04:43:23.519 2009   (  6.99) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  53  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:43:16.578 2009  to  Mon Jun 15 04:43:23.467 2009   (  6.89) secs
                     left PSF ApplyZernikes failed

  54  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:43:16.733 2009  to  Mon Jun 15 04:43:23.415 2009   (  6.68) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:43:21.197 2009  to  Mon Jun 15 04:43:23.363 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:46:06.358 2009  to  Mon Jun 15 04:46:08.732 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  57  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:46:06.409 2009  to  Mon Jun 15 04:46:08.679 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:46:06.460 2009  to  Mon Jun 15 04:46:08.626 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:46:41.530 2009  to  Mon Jun 15 04:46:43.903 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  60  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:46:41.581 2009  to  Mon Jun 15 04:46:43.851 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:46:41.632 2009  to  Mon Jun 15 04:46:43.799 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:47:36.363 2009  to  Mon Jun 15 04:47:38.771 2009   (  2.41) secs
                     left PSF SetInstrumentOffsets failed

  63  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:47:36.413 2009  to  Mon Jun 15 04:47:38.719 2009   (  2.31) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:47:36.465 2009  to  Mon Jun 15 04:47:38.667 2009   (  2.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:56:27.727 2009  to  Mon Jun 15 04:56:30.106 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

  66  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:56:27.778 2009  to  Mon Jun 15 04:56:30.053 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:56:27.829 2009  to  Mon Jun 15 04:56:30.000 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  68  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 05:08:43.763 2009  to  Mon Jun 15 05:08:49.205 2009   (  5.44) secs
                     left PSF ApplyZernikes failed

  69  FAILED    PSF        command.setZernikes                                           Mon Jun 15 05:08:43.713 2009  to  Mon Jun 15 05:08:49.257 2009   (  5.54) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  70  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 05:08:43.915 2009  to  Mon Jun 15 05:08:49.153 2009   (  5.24) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  71  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:08:46.932 2009  to  Mon Jun 15 05:08:49.100 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  72  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:14:26.062 2009  to  Mon Jun 15 05:14:28.440 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

  73  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:14:26.164 2009  to  Mon Jun 15 05:14:28.335 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  74  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:14:26.113 2009  to  Mon Jun 15 05:14:28.387 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  75  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 05:26:50.394 2009  to  Mon Jun 15 05:26:55.923 2009   (  5.53) secs
                     left PSF ApplyZernikes failed

  76  FAILED    PSF        command.setZernikes                                           Mon Jun 15 05:26:50.343 2009  to  Mon Jun 15 05:26:55.975 2009   (  5.63) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  77  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 05:26:50.639 2009  to  Mon Jun 15 05:26:55.871 2009   (  5.23) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:26:53.654 2009  to  Mon Jun 15 05:26:55.819 2009   (  2.16) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:26:56.825 2009  to  Mon Jun 15 05:26:57.196 2009   (  0.37) secs
                     left PSF SetInstrumentOffsets failed

  80  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:26:56.876 2009  to  Mon Jun 15 05:26:57.145 2009   (  0.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  81  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:26:56.928 2009  to  Mon Jun 15 05:26:57.092 2009   (  0.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  82  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:34:08.101 2009  to  Mon Jun 15 05:34:10.476 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  83  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:34:08.203 2009  to  Mon Jun 15 05:34:10.371 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:34:08.152 2009  to  Mon Jun 15 05:34:10.424 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  85  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:36:13.976 2009  to  Mon Jun 15 05:36:16.431 2009   (  2.46) secs
                     left PSF SetInstrumentOffsets failed

  86  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:36:14.161 2009  to  Mon Jun 15 05:36:16.326 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:36:14.110 2009  to  Mon Jun 15 05:36:16.379 2009   (  2.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  88  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:38:14.009 2009  to  Mon Jun 15 05:38:16.389 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

  89  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:38:14.061 2009  to  Mon Jun 15 05:38:16.337 2009   (  2.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  90  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:38:14.112 2009  to  Mon Jun 15 05:38:16.285 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Jun 15 01:16:18.089 2009  to  Mon Jun 15 01:16:19.253 2009   (  1.16) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Jun 15 01:16:18.093 2009  to  Mon Jun 15 01:16:18.507 2009   (  0.41) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.151 2009  to  Mon Jun 15 01:16:18.210 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  FAILED    PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.210 2009  to  Mon Jun 15 01:16:18.213 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   5  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:18.294 2009  to  Mon Jun 15 01:16:18.294 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  FAILED    PSF        command.setNewInstrument                                      Mon Jun 15 01:16:18.477 2009  to  Mon Jun 15 01:16:18.994 2009   (  0.52) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

   7  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Mon Jun 15 01:16:18.528 2009  to  Mon Jun 15 01:16:18.688 2009   (  0.16) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   8  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:31.939 2009  to  Mon Jun 15 01:16:31.997 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   9  SEQERROR  PCS        telescope.command.stopTracking                                Mon Jun 15 01:16:32.102 2009  to  Mon Jun 15 01:16:32.102 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  10  FAILED    PSF        primaryMirror.command.revert                                  Mon Jun 15 01:23:13.307 2009  to  Mon Jun 15 01:23:19.890 2009   (  6.58) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 01:23:17.588 2009  to  Mon Jun 15 01:23:19.837 2009   (  2.25) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 01:23:17.645 2009  to  Mon Jun 15 01:23:19.783 2009   (  2.14) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 01:23:26.829 2009  to  Mon Jun 15 01:23:26.990 2009   (  0.16) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  14  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Mon Jun 15 01:23:26.781 2009  to  Mon Jun 15 01:23:27.042 2009   (  0.26) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 01:23:26.884 2009  to  Mon Jun 15 01:23:26.934 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jun 15 03:56:07.372 2009  to  Mon Jun 15 03:58:00.994 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  17  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:57:28.074 2009  to  Mon Jun 15 03:58:03.372 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  18  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:57:28.132 2009  to  Mon Jun 15 03:58:03.429 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  19  FAILED    IIF        command.preset.(TRACK)                                        Mon Jun 15 03:58:00.994 2009  to  Mon Jun 15 03:58:09.775 2009   (  8.78) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

  20  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:58:03.429 2009  to  Mon Jun 15 03:58:03.480 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:58:03.372 2009  to  Mon Jun 15 03:58:03.579 2009   (  0.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  22  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 03:58:34.284 2009  to  Mon Jun 15 03:58:34.284 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  23  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 03:58:34.341 2009  to  Mon Jun 15 03:58:34.341 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  24  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jun 15 03:58:36.530 2009  to  Mon Jun 15 03:58:36.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  25  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:36.704 2009  to  Mon Jun 15 03:58:36.704 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.0469806e-03 1.7477870e-03 -5.6981444e-03 -5.2488327e-02 1.1022186e-01 2.9969215e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:36.957 2009  to  Mon Jun 15 03:58:36.957 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.210 2009  to  Mon Jun 15 03:58:37.210 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.463 2009  to  Mon Jun 15 03:58:37.463 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.716 2009  to  Mon Jun 15 03:58:37.716 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.7015717e-03 1.8271953e-03 -5.3565502e-03 -2.9056549e-02 3.1982422e-02 7.1344376e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:37.969 2009  to  Mon Jun 15 03:58:37.969 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5204630e-03 2.0537078e-03 -5.1375031e-03 -4.6501160e-02 9.7423553e-02 2.0063400e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.222 2009  to  Mon Jun 15 03:58:38.222 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.475 2009  to  Mon Jun 15 03:58:38.475 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.728 2009  to  Mon Jun 15 03:58:38.728 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:38.981 2009  to  Mon Jun 15 03:58:38.981 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.234 2009  to  Mon Jun 15 03:58:39.234 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.487 2009  to  Mon Jun 15 03:58:39.487 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.740 2009  to  Mon Jun 15 03:58:39.740 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:39.993 2009  to  Mon Jun 15 03:58:39.993 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.246 2009  to  Mon Jun 15 03:58:40.246 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.499 2009  to  Mon Jun 15 03:58:40.499 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:40.752 2009  to  Mon Jun 15 03:58:40.752 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.005 2009  to  Mon Jun 15 03:58:41.005 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.258 2009  to  Mon Jun 15 03:58:41.258 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.511 2009  to  Mon Jun 15 03:58:41.511 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:41.764 2009  to  Mon Jun 15 03:58:41.764 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.5026561e-03 1.4636815e-03 -5.1329136e-03 -3.7137985e-02 5.8731079e-02 1.9802094e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.017 2009  to  Mon Jun 15 03:58:42.017 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.270 2009  to  Mon Jun 15 03:58:42.270 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.4830909e-03 1.3949871e-03 -5.0955415e-03 -6.1143875e-02 1.0244751e-01 4.3019295e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.523 2009  to  Mon Jun 15 03:58:42.523 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.4830909e-03 1.3949871e-03 -5.0955415e-03 -6.1143875e-02 1.0244751e-01 4.3019295e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Mon Jun 15 03:58:42.776 2009  to  Mon Jun 15 03:58:42.776 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.6820065e-03 1.7584860e-03 -5.3191185e-03 -5.3064346e-02 7.5695038e-02 3.0351639e-02

  50  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:23:07.975 2009  to  Mon Jun 15 04:23:25.856 2009   ( 17.88) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  51  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:23:07.919 2009  to  Mon Jun 15 04:23:25.963 2009   ( 18.04) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  52  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:23:08.025 2009  to  Mon Jun 15 04:23:25.802 2009   ( 17.78) secs
                     right PSF ApplyZernikes failed

  53  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:23:08.181 2009  to  Mon Jun 15 04:23:25.749 2009   ( 17.57) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:23:10.506 2009  to  Mon Jun 15 04:23:25.697 2009   ( 15.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:23:10.562 2009  to  Mon Jun 15 04:23:25.634 2009   ( 15.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:23:28.084 2009  to  Mon Jun 15 04:23:33.109 2009   (  5.02) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

  57  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:23:28.195 2009  to  Mon Jun 15 04:23:32.949 2009   (  4.75) secs
                     left PSF ApplyZernikes failed

  58  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:23:28.144 2009  to  Mon Jun 15 04:23:33.003 2009   (  4.86) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  59  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:23:28.352 2009  to  Mon Jun 15 04:23:32.898 2009   (  4.55) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:23:30.677 2009  to  Mon Jun 15 04:23:32.846 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:23:30.735 2009  to  Mon Jun 15 04:23:32.790 2009   (  2.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    IIF        command.preset.(TRACK)                                        Mon Jun 15 04:26:57.147 2009  to  Mon Jun 15 04:27:48.007 2009   ( 50.86) secs
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

  63  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:13.806 2009  to  Mon Jun 15 04:27:27.753 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:13.751 2009  to  Mon Jun 15 04:27:27.640 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  65  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:27.700 2009  to  Mon Jun 15 04:27:35.105 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:27.640 2009  to  Mon Jun 15 04:27:27.861 2009   (  0.22) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:27.641 2009  to  Mon Jun 15 04:27:35.049 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:27.753 2009  to  Mon Jun 15 04:27:27.803 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:29.881 2009  to  Mon Jun 15 04:27:29.881 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  70  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:29.938 2009  to  Mon Jun 15 04:27:29.938 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  71  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:27:31.396 2009  to  Mon Jun 15 04:27:35.473 2009   (  4.08) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

  72  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:27:31.453 2009  to  Mon Jun 15 04:27:35.367 2009   (  3.91) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  73  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:27:31.565 2009  to  Mon Jun 15 04:27:35.315 2009   (  3.75) secs
                     left PSF ApplyZernikes failed

  74  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:27:31.718 2009  to  Mon Jun 15 04:27:35.263 2009   (  3.54) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  75  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:35.049 2009  to  Mon Jun 15 04:27:35.211 2009   (  0.16) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  76  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:35.105 2009  to  Mon Jun 15 04:27:35.156 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  77  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:27:47.780 2009  to  Mon Jun 15 04:27:47.780 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  78  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:27:47.838 2009  to  Mon Jun 15 04:27:47.838 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  79  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 04:43:16.471 2009  to  Mon Jun 15 04:43:23.626 2009   (  7.15) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

  80  FAILED    PSF        command.setZernikes                                           Mon Jun 15 04:43:16.528 2009  to  Mon Jun 15 04:43:23.519 2009   (  6.99) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  81  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 04:43:16.578 2009  to  Mon Jun 15 04:43:23.467 2009   (  6.89) secs
                     left PSF ApplyZernikes failed

  82  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 04:43:16.733 2009  to  Mon Jun 15 04:43:23.415 2009   (  6.68) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:43:21.197 2009  to  Mon Jun 15 04:43:23.363 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:43:21.255 2009  to  Mon Jun 15 04:43:23.308 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:46:06.303 2009  to  Mon Jun 15 04:46:08.890 2009   (  2.59) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719868055556e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -1.000000000000000e-01

  86  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:46:06.358 2009  to  Mon Jun 15 04:46:08.732 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  87  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:46:06.409 2009  to  Mon Jun 15 04:46:08.679 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  88  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:46:06.460 2009  to  Mon Jun 15 04:46:08.626 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  89  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:46:06.517 2009  to  Mon Jun 15 04:46:08.570 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  90  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:46:41.474 2009  to  Mon Jun 15 04:46:44.062 2009   (  2.59) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719908564815e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -2.000000000000000e-02

  91  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:46:41.530 2009  to  Mon Jun 15 04:46:43.903 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  92  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:46:41.581 2009  to  Mon Jun 15 04:46:43.851 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  93  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:46:41.632 2009  to  Mon Jun 15 04:46:43.799 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  94  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:46:41.688 2009  to  Mon Jun 15 04:46:43.742 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  95  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:47:36.363 2009  to  Mon Jun 15 04:47:38.771 2009   (  2.41) secs
                     left PSF SetInstrumentOffsets failed

  96  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:47:36.307 2009  to  Mon Jun 15 04:47:38.926 2009   (  2.62) secs
                     IIF GetTrajectory command started for both LBC, start time 5.499719972222222e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-02

  97  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:47:36.413 2009  to  Mon Jun 15 04:47:38.719 2009   (  2.31) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  98  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:47:36.521 2009  to  Mon Jun 15 04:47:38.615 2009   (  2.09) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  99  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:47:36.465 2009  to  Mon Jun 15 04:47:38.667 2009   (  2.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 100  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 04:56:27.727 2009  to  Mon Jun 15 04:56:30.106 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

 101  FAILED    IIF        command.moveFocus                                             Mon Jun 15 04:56:27.673 2009  to  Mon Jun 15 04:56:30.316 2009   (  2.64) secs
                     IIF MoveFocus command started for right LBC for 2.430000000000000e+00
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.430000000000000e+00

 102  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 04:56:27.778 2009  to  Mon Jun 15 04:56:30.053 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 103  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 04:56:27.887 2009  to  Mon Jun 15 04:56:29.942 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 104  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 04:56:27.829 2009  to  Mon Jun 15 04:56:30.000 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 105  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 05:08:43.655 2009  to  Mon Jun 15 05:08:49.363 2009   (  5.71) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

 106  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 05:08:43.763 2009  to  Mon Jun 15 05:08:49.205 2009   (  5.44) secs
                     left PSF ApplyZernikes failed

 107  FAILED    PSF        command.setZernikes                                           Mon Jun 15 05:08:43.713 2009  to  Mon Jun 15 05:08:49.257 2009   (  5.54) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 108  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 05:08:43.915 2009  to  Mon Jun 15 05:08:49.153 2009   (  5.24) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 109  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:08:46.932 2009  to  Mon Jun 15 05:08:49.100 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 110  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:08:46.989 2009  to  Mon Jun 15 05:08:49.043 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 111  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:14:26.062 2009  to  Mon Jun 15 05:14:28.440 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

 112  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:14:26.007 2009  to  Mon Jun 15 05:14:28.600 2009   (  2.59) secs
                     IIF MoveFocus command started for right LBC for 3.800000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 3.800000000000000e-01

 113  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:14:26.164 2009  to  Mon Jun 15 05:14:28.335 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 114  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:14:26.113 2009  to  Mon Jun 15 05:14:28.387 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 115  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:14:26.220 2009  to  Mon Jun 15 05:14:28.276 2009   (  2.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 116  FAILED    PMC        VxInterface.lengthError                                       Mon Jun 15 05:14:28.826 2009  to  Mon Jun 15 05:14:28.826 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 117  FAILED    PMC        VxInterface.close                                             Mon Jun 15 05:14:28.876 2009  to  Mon Jun 15 05:14:28.876 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 118  FAILED    IIF        command.sendWavefront                                         Mon Jun 15 05:26:50.285 2009  to  Mon Jun 15 05:26:56.081 2009   (  5.80) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

 119  FAILED    PSF        command.applyZernikes                                         Mon Jun 15 05:26:50.394 2009  to  Mon Jun 15 05:26:55.923 2009   (  5.53) secs
                     left PSF ApplyZernikes failed

 120  FAILED    PSF        command.setZernikes                                           Mon Jun 15 05:26:50.343 2009  to  Mon Jun 15 05:26:55.975 2009   (  5.63) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 121  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jun 15 05:26:50.639 2009  to  Mon Jun 15 05:26:55.871 2009   (  5.23) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 122  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:26:53.654 2009  to  Mon Jun 15 05:26:55.819 2009   (  2.16) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 123  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:26:53.710 2009  to  Mon Jun 15 05:26:55.763 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 124  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:26:56.769 2009  to  Mon Jun 15 05:26:57.352 2009   (  0.58) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 125  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:26:56.825 2009  to  Mon Jun 15 05:26:57.196 2009   (  0.37) secs
                     left PSF SetInstrumentOffsets failed

 126  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:26:56.876 2009  to  Mon Jun 15 05:26:57.145 2009   (  0.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 127  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:26:56.984 2009  to  Mon Jun 15 05:26:57.034 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 128  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:26:56.928 2009  to  Mon Jun 15 05:26:57.092 2009   (  0.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 129  FAILED    PMC        VxInterface.lengthError                                       Mon Jun 15 05:27:40.698 2009  to  Mon Jun 15 05:27:40.698 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 130  FAILED    PMC        VxInterface.close                                             Mon Jun 15 05:27:40.748 2009  to  Mon Jun 15 05:27:40.748 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 131  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:34:08.101 2009  to  Mon Jun 15 05:34:10.476 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

 132  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:34:08.045 2009  to  Mon Jun 15 05:34:10.634 2009   (  2.59) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 133  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:34:08.203 2009  to  Mon Jun 15 05:34:10.371 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 134  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:34:08.152 2009  to  Mon Jun 15 05:34:10.424 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 135  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:34:08.260 2009  to  Mon Jun 15 05:34:10.313 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 136  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:36:13.919 2009  to  Mon Jun 15 05:36:16.588 2009   (  2.67) secs
                     IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 137  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:36:13.976 2009  to  Mon Jun 15 05:36:16.431 2009   (  2.46) secs
                     left PSF SetInstrumentOffsets failed

 138  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:36:14.161 2009  to  Mon Jun 15 05:36:16.326 2009   (  2.17) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 139  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:36:14.110 2009  to  Mon Jun 15 05:36:16.379 2009   (  2.27) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 140  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:36:14.217 2009  to  Mon Jun 15 05:36:16.270 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 141  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jun 15 05:38:14.009 2009  to  Mon Jun 15 05:38:16.389 2009   (  2.38) secs
                     right PSF SetInstrumentOffsets failed

 142  FAILED    IIF        command.moveFocus                                             Mon Jun 15 05:38:13.953 2009  to  Mon Jun 15 05:38:16.549 2009   (  2.60) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 143  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jun 15 05:38:14.061 2009  to  Mon Jun 15 05:38:16.337 2009   (  2.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 144  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jun 15 05:38:14.171 2009  to  Mon Jun 15 05:38:16.226 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 145  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jun 15 05:38:14.112 2009  to  Mon Jun 15 05:38:16.285 2009   (  2.17) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

**********************************************************
    Reporting period ending:   Mon Jun 15 04:49:50.720 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.