You are here: Foswiki>Software Web>TCSSWReportFile_090612 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jun 12 2009 to Jun 13 2009
 
    Reporting period beginning:   Fri Jun 12 18:58:06.438 2009
    Reporting period ending:      Sat Jun 13 05:25:44.202 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.02    0.06    0.05    0.14   100.0 %         19         19                      
                                                                       0.02    0.06    0.05    0.14
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.02    0.22    0.21    0.29   100.0 %         27         27                      
                                                                       0.02    0.22    0.21    0.29
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.39    6.52    2.48   21.51    92.9 %         42         39          3           
                                                                       4.46    6.67    2.48   21.51
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    3.48   14.99   10.77   19.28    75.0 %          4          3          1           
                                                                       2.51   16.39   14.86   19.28
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.62    2.56    2.07    3.46   100.0 %          4          4                      
                                                                       0.62    2.56    2.07    3.46
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .  146.13  131.03   27.70  234.35    50.0 %          2          1          1           
                                                                       0.00   27.70   27.70   27.70
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   24.20   62.92   45.81   80.03   100.0 %          2          2                      
                                                                      24.20   62.92   45.81   80.03
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   39.93   67.21   38.98   95.45   100.0 %          2          2                      
                                                                      39.93   67.21   38.98   95.45
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   23.09   18.75    2.06   61.15   100.0 %          6          6                      
                                                                      23.09   18.75    2.06   61.15
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.44    2.26    2.06    3.05   100.0 %          5          5                      
                                                                       0.44    2.26    2.06    3.05
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .   10.17   15.14    6.78   45.75    94.4 %         18         16          1           
                                                                      10.26   15.66    6.98   45.75

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACQUIRE)                                      Sat Jun 13 01:27:30.613 2009  to  Sat Jun 13 01:31:24.967 2009   (234.35) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   2  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:01:04.460 2009  to  Sat Jun 13 05:01:07.065 2009   (  2.61) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   3  FAILED    IIF        command.offset                                                Sat Jun 13 05:04:47.764 2009  to  Sat Jun 13 05:04:58.533 2009   ( 10.77) secs
                     IIF Offset command wait for telescope started for left IRTC
                     IIF Offset alert for left IRTC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Offset command failed for left IRTC from IIF

   4  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:09:44.788 2009  to  Sat Jun 13 05:09:47.369 2009   (  2.58) secs
                     IIF GetTrajectory command started for right LBC, start time 5.499521510416667e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   5  FAILED    IIF        command.sendWavefront                                         Sat Jun 13 05:28:19.579 2009  to  Sat Jun 13 05:28:26.360 2009   (  6.78) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   6  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:31:29.519 2009  to  Sat Jun 13 05:31:38.125 2009   (  8.61) secs
                     IIF GetTrajectory command started for right LBC, start time 5.499523019675926e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.400000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3201                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6402                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      88                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    6.54   16.96   12.33   21.59   100.0 %          2          2                      
                                                                       6.54   16.96   12.33   21.59
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.24    0.21    0.00    0.47    50.0 %          2          4                      
                                                                       0.24    0.21    0.00    0.47
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    0.31    8.04    7.68    8.41   100.0 %          4          4                      
                                                                       0.31    8.04    7.68    8.41
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.04    0.11    0.05    0.14   100.0 %          4          4                      
                                                                       0.04    0.11    0.05    0.14
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    1.73    4.06    3.06    6.06   100.0 %          3          3                      
                                                                       1.73    4.06    3.06    6.06
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    3.26   18.39   14.07   21.74   100.0 %          4          4                      
                                                                       3.26   18.39   14.07   21.74
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.00    0.39    0.39    0.39    14.3 %          7          1                      
                                                                       0.00    0.39    0.39    0.39
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.00    0.18    0.18    0.18   100.0 %          1          1                      
                                                                       0.00    0.18    0.18    0.18
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    5.94   12.56    7.36   21.42   100.0 %          8          8                      
                                                                       5.94   12.56    7.36   21.42
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    0.53    2.29    2.17   13.46    99.6 %       1028       1024                        interrupted =     4
                                                                       0.53    2.29    2.17   13.46
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    0.58   32.47   32.31   36.94    93.9 %         66         62                        interrupted =     3
                                                                       0.58   32.47   32.31   36.94
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.00    0.16    0.16    0.16   100.0 %          8          8                      
                                                                       0.00    0.16    0.16    0.16
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.02    0.17    0.13    0.39   100.0 %       1022       1022                      
                                                                       0.02    0.17    0.13    0.39
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.00    2.72    2.72    2.72   100.0 %          2          2                      
                                                                       0.00    2.72    2.72    2.72
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .    2.13   12.83    9.17   23.88   100.0 %         62         62                      
                                                                       2.13   12.83    9.17   23.88
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.05    0.23    0.15    0.38   100.0 %         62         62                      
                                                                       0.05    0.23    0.15    0.38

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .       2                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .       2                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                             5
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .       2                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .       1                      

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      11                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       8                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      13                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             4
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       3                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            30
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            16
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      29                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     100                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            88
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            13
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      83                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.velocityNotZero. . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.AzBrakes.allBrakesSetQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.brakesNotOn. . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      62                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .      65                      
     MCSPU.RTracker.commandToVelMode. . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.regen_ok_not . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       5                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.Cabinet.cabinetOff . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.nullState. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.commandIgnored . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.stowpinMoving . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       6                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      26                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      42                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      39                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      42                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      21                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      21                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      79                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     114                      
     MCSPU.RTracker.trackLimitWarning . . . . . . . . . . . . . . .      15                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     127                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.brakesNotOn                                     Fri Jun 12 19:38:21.276 2009  to  Fri Jun 12 19:38:21.276 2009   (  0.00) secs
                     Brakes not set AND the telescope is moving even though amps are off! Trying to set brakes.

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Jun 12 19:40:17.685 2009  to  Fri Jun 12 19:40:17.685 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Jun 12 19:40:17.729 2009  to  Fri Jun 12 19:40:17.729 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off:

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jun 12 19:40:17.687 2009  to  Fri Jun 12 19:40:17.687 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off:

   5  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jun 12 19:40:17.786 2009  to  Fri Jun 12 19:40:17.786 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off:

   6  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Jun 12 19:40:17.841 2009  to  Fri Jun 12 19:40:17.841 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off:

   7  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jun 12 19:44:03.452 2009  to  Fri Jun 12 19:44:03.452 2009   (  0.00) secs
                     Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

   8  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jun 12 19:44:03.453 2009  to  Fri Jun 12 19:44:03.453 2009   (  0.00) secs
                     Axis drive command was ignored because the drive cabinet is turned off.

   9  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 19:48:07.727 2009  to  Fri Jun 12 19:48:07.727 2009   (  0.00) secs
                     drive cabinet has turned on.

  10  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jun 12 19:48:09.875 2009  to  Fri Jun 12 19:48:09.875 2009   (  0.00) secs
                     Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

  11  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jun 12 19:48:09.875 2009  to  Fri Jun 12 19:48:09.875 2009   (  0.00) secs
                     Axis drive command was ignored because the drive cabinet is turned off.

  12  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 19:48:13.065 2009  to  Fri Jun 12 19:48:13.065 2009   (  0.00) secs
                     drive cabinet has turned on.

  13  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jun 12 19:48:25.715 2009  to  Fri Jun 12 19:48:25.715 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jun 12 19:58:11.318 2009  to  Fri Jun 12 19:58:11.318 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  15  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jun 12 19:58:11.419 2009  to  Fri Jun 12 19:58:11.419 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jun 12 21:15:13.292 2009  to  Fri Jun 12 21:15:13.292 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jun 12 21:15:13.306 2009  to  Fri Jun 12 21:15:13.306 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  18  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 21:15:13.399 2009  to  Fri Jun 12 21:15:13.399 2009   (  0.00) secs
                     drive cabinet has turned on.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.407 2009  to  Fri Jun 12 21:15:14.407 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.407 2009  to  Fri Jun 12 21:15:14.407 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.408 2009  to  Fri Jun 12 21:15:14.408 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.408 2009  to  Fri Jun 12 21:15:14.408 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.409 2009  to  Fri Jun 12 21:15:14.409 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.409 2009  to  Fri Jun 12 21:15:14.409 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.410 2009  to  Fri Jun 12 21:15:14.410 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.410 2009  to  Fri Jun 12 21:15:14.410 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Jun 13 03:19:29.972 2009  to  Sat Jun 13 03:19:29.972 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  28  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sat Jun 13 04:54:23.721 2009  to  Sat Jun 13 04:54:23.721 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:14:43.218 2009  to  Sat Jun 13 05:14:43.218 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:16:49.764 2009  to  Sat Jun 13 05:16:49.764 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:17:10.259 2009  to  Sat Jun 13 05:17:10.259 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:25:44.202 2009  to  Sat Jun 13 05:25:44.202 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    2.47    8.34    2.35   18.45   100.0 %         71         71                      
                                                                       2.47    8.34    2.35   18.45
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.38    3.10    2.53    3.46    83.3 %          6          5                      
                                                                       0.38    3.10    2.53    3.46

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             1
     .tel . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       4                      

OSS Events of Interest

   1  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Sat Jun 13 01:28:52.598 2009  to  Sat Jun 13 01:32:22.555 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   2  STARTUP   OSS        startup                                                       Sat Jun 13 01:31:30.995 2009  to  Sat Jun 13 01:31:30.995 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          8          8                      
                                                                       0.00    0.05    0.05    0.05
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.04    0.14   100.0 %       1022       1022                      
                                                                       0.01    0.05    0.04    0.14
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.00    2.61    2.61    2.61   100.0 %          2          2                        largeUpdate =     2
                                                                       0.00    2.61    2.61    2.61
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.00    0.09    0.09    0.11   100.0 %         27         27                      
                                                                       0.00    0.09    0.09    0.11
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.04    0.05   100.0 %          7          7                      
                                                                       0.00    0.05    0.04    0.05
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.reloadAuthorizedPM . . . . . . . . . . . . .    0.00    0.11    0.11    0.11   100.0 %          1          1                      
                                                                       0.00    0.11    0.11    0.11
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         11         11                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.14    0.44    0.31    0.56   100.0 %          6          6                      
                                                                       0.14    0.44    0.31    0.56

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telemetryInfo. . . . . . . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.06    2.43    2.05    9.07    98.7 %         75         74                      
                                                                       1.06    2.43    2.05    9.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    2.83    4.06    2.05    6.06   100.0 %          2          2                      
                                                                       2.83    4.06    2.05    6.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   10.19    9.21    2.05   57.14    93.3 %         75         70          5           
                                                                      10.40    9.64    2.05   57.14
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            49
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      14                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      14                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       2                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      75                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            37
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:01:04.673 2009  to  Sat Jun 13 05:01:06.728 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:04:50.804 2009  to  Sat Jun 13 05:04:52.857 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:09:44.997 2009  to  Sat Jun 13 05:09:47.050 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:47.957 2009  to  Sat Jun 13 05:09:47.957 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

   5  FAILED    PMC        VxInterface.packetReadError                                   Sat Jun 13 05:09:48.008 2009  to  Sat Jun 13 05:09:48.008 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

   6  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:48.360 2009  to  Sat Jun 13 05:09:48.360 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

   7  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:48.712 2009  to  Sat Jun 13 05:09:48.712 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

   8  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:49.063 2009  to  Sat Jun 13 05:09:49.063 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

   9  FAILED    PMC        VxInterface.lengthError                                       Sat Jun 13 05:12:46.780 2009  to  Sat Jun 13 05:12:46.780 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.close                                             Sat Jun 13 05:12:46.831 2009  to  Sat Jun 13 05:12:46.831 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:28:23.989 2009  to  Sat Jun 13 05:28:26.042 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:31:29.732 2009  to  Sat Jun 13 05:31:37.794 2009   (  8.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.93   12.90    6.52   45.53    98.8 %         80         78          1           
                                                                       4.91   12.98    6.76   45.53
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    1.83    0.87    0.25    5.77   100.0 %          9          9                      
                                                                       1.83    0.87    0.25    5.77
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.40    6.39    2.37   21.40    92.9 %         42         39          3           
                                                                       4.46    6.54    2.37   21.40
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.93   13.00    6.62   45.63    98.8 %         80         78          1           
                                                                       4.91   13.09    6.86   45.63
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.66    5.68    0.13   45.32    98.8 %         80         78          1           
                                                                       6.70    5.67    0.13   45.32
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   10.19    9.34    2.16   57.25    93.3 %         75         70          5           
                                                                      10.40    9.76    2.17   57.25
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    2.82    4.18    2.19    6.18   100.0 %          2          2                      
                                                                       2.82    4.18    2.19    6.18
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.08    0.06    0.18   100.0 %        376        376                      
                                                                       0.03    0.08    0.06    0.18
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   63.62   63.62   63.62   100.0 %          1          1                      
                                                                       0.00   63.62   63.62   63.62
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    1.67    7.11    4.28    8.42   100.0 %          5          5                      
                                                                       1.67    7.11    4.28    8.42
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.40    6.29    2.27   21.30    92.9 %         42         39          3           
                                                                       4.46    6.44    2.27   21.30
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.05   100.0 %          9          9                      
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00   17.39   17.39   17.39   100.0 %          1          1                      
                                                                       0.00   17.39   17.39   17.39
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         80         80                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.73    8.78    5.64   15.63   100.0 %         62         62                      
                                                                       1.73    8.78    5.64   15.63
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    2.46    8.46    2.47   18.56   100.0 %         71         71                      
                                                                       2.46    8.46    2.47   18.56
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.02    0.06    0.05    0.10   100.0 %          9          9                      
                                                                       0.02    0.06    0.05    0.10
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.01    0.05    0.05    0.14   100.0 %         62         62                      
                                                                       0.01    0.05    0.05    0.14
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .   60.83   28.08    2.79  152.25    83.3 %          6          5          1           
                                                                       0.33    3.25    2.79    3.57

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Sat Jun 13 01:28:52.543 2009  to  Sat Jun 13 01:31:24.796 2009   (152.25) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

   2  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:01:04.515 2009  to  Sat Jun 13 05:01:06.902 2009   (  2.39) secs
                     right PSF SetInstrumentOffsets failed

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:01:04.617 2009  to  Sat Jun 13 05:01:06.796 2009   (  2.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:01:04.566 2009  to  Sat Jun 13 05:01:06.850 2009   (  2.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:04:50.745 2009  to  Sat Jun 13 05:04:52.910 2009   (  2.17) secs
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:09:44.843 2009  to  Sat Jun 13 05:09:47.210 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

   7  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:09:44.893 2009  to  Sat Jun 13 05:09:47.159 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:09:44.943 2009  to  Sat Jun 13 05:09:47.107 2009   (  2.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PSF        command.setZernikes                                           Sat Jun 13 05:28:19.635 2009  to  Sat Jun 13 05:28:26.252 2009   (  6.62) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  10  FAILED    PSF        command.applyZernikes                                         Sat Jun 13 05:28:19.685 2009  to  Sat Jun 13 05:28:26.201 2009   (  6.52) secs
                     right PSF ApplyZernikes failed

  11  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Jun 13 05:28:19.840 2009  to  Sat Jun 13 05:28:26.150 2009   (  6.31) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:28:23.935 2009  to  Sat Jun 13 05:28:26.099 2009   (  2.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:31:29.576 2009  to  Sat Jun 13 05:31:37.965 2009   (  8.39) secs
                     right PSF SetInstrumentOffsets failed

  14  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:31:29.626 2009  to  Sat Jun 13 05:31:37.911 2009   (  8.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  15  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:31:29.676 2009  to  Sat Jun 13 05:31:37.856 2009   (  8.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF        command.preset.(ACQUIRE)                                      Sat Jun 13 01:27:30.613 2009  to  Sat Jun 13 01:31:24.967 2009   (234.35) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   2  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Sat Jun 13 01:28:52.543 2009  to  Sat Jun 13 01:31:24.796 2009   (152.25) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

   3  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Sat Jun 13 01:28:52.598 2009  to  Sat Jun 13 01:32:22.555 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   4  STARTUP   OSS        startup                                                       Sat Jun 13 01:31:30.995 2009  to  Sat Jun 13 01:31:30.995 2009   (  0.00) secs
                     The oss was started.

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.brakesNotOn                                     Fri Jun 12 19:38:21.276 2009  to  Fri Jun 12 19:38:21.276 2009   (  0.00) secs
                     Brakes not set AND the telescope is moving even though amps are off! Trying to set brakes.

   6  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Jun 12 19:40:17.685 2009  to  Fri Jun 12 19:40:17.685 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   7  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Jun 12 19:40:17.729 2009  to  Fri Jun 12 19:40:17.729 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off:

   8  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jun 12 19:40:17.687 2009  to  Fri Jun 12 19:40:17.687 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off:

   9  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jun 12 19:40:17.786 2009  to  Fri Jun 12 19:40:17.786 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off:

  10  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Jun 12 19:40:17.841 2009  to  Fri Jun 12 19:40:17.841 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off:

  11  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jun 12 19:44:03.452 2009  to  Fri Jun 12 19:44:03.452 2009   (  0.00) secs
                     Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

  12  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jun 12 19:44:03.453 2009  to  Fri Jun 12 19:44:03.453 2009   (  0.00) secs
                     Axis drive command was ignored because the drive cabinet is turned off.

  13  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 19:48:07.727 2009  to  Fri Jun 12 19:48:07.727 2009   (  0.00) secs
                     drive cabinet has turned on.

  14  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jun 12 19:48:09.875 2009  to  Fri Jun 12 19:48:09.875 2009   (  0.00) secs
                     Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

  15  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jun 12 19:48:09.875 2009  to  Fri Jun 12 19:48:09.875 2009   (  0.00) secs
                     Axis drive command was ignored because the drive cabinet is turned off.

  16  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 19:48:13.065 2009  to  Fri Jun 12 19:48:13.065 2009   (  0.00) secs
                     drive cabinet has turned on.

  17  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jun 12 19:48:25.715 2009  to  Fri Jun 12 19:48:25.715 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  18  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jun 12 19:58:11.318 2009  to  Fri Jun 12 19:58:11.318 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  19  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jun 12 19:58:11.419 2009  to  Fri Jun 12 19:58:11.419 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jun 12 21:15:13.292 2009  to  Fri Jun 12 21:15:13.292 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jun 12 21:15:13.306 2009  to  Fri Jun 12 21:15:13.306 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  22  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jun 12 21:15:13.399 2009  to  Fri Jun 12 21:15:13.399 2009   (  0.00) secs
                     drive cabinet has turned on.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.407 2009  to  Fri Jun 12 21:15:14.407 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.407 2009  to  Fri Jun 12 21:15:14.407 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.408 2009  to  Fri Jun 12 21:15:14.408 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.408 2009  to  Fri Jun 12 21:15:14.408 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.409 2009  to  Fri Jun 12 21:15:14.409 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.409 2009  to  Fri Jun 12 21:15:14.409 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.410 2009  to  Fri Jun 12 21:15:14.410 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jun 12 21:15:14.410 2009  to  Fri Jun 12 21:15:14.410 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:01:04.460 2009  to  Sat Jun 13 05:01:07.065 2009   (  2.61) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  32  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:01:04.515 2009  to  Sat Jun 13 05:01:06.902 2009   (  2.39) secs
                     right PSF SetInstrumentOffsets failed

  33  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:01:04.617 2009  to  Sat Jun 13 05:01:06.796 2009   (  2.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:01:04.566 2009  to  Sat Jun 13 05:01:06.850 2009   (  2.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  35  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:01:04.673 2009  to  Sat Jun 13 05:01:06.728 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  36  FAILED    IIF        command.offset                                                Sat Jun 13 05:04:47.764 2009  to  Sat Jun 13 05:04:58.533 2009   ( 10.77) secs
                     IIF Offset command wait for telescope started for left IRTC
                     IIF Offset alert for left IRTC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Offset command failed for left IRTC from IIF

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:04:50.745 2009  to  Sat Jun 13 05:04:52.910 2009   (  2.17) secs
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:04:50.804 2009  to  Sat Jun 13 05:04:52.857 2009   (  2.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:09:44.843 2009  to  Sat Jun 13 05:09:47.210 2009   (  2.37) secs
                     right PSF SetInstrumentOffsets failed

  40  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:09:44.788 2009  to  Sat Jun 13 05:09:47.369 2009   (  2.58) secs
                     IIF GetTrajectory command started for right LBC, start time 5.499521510416667e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  41  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:09:44.893 2009  to  Sat Jun 13 05:09:47.159 2009   (  2.27) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  42  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:09:44.997 2009  to  Sat Jun 13 05:09:47.050 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:09:44.943 2009  to  Sat Jun 13 05:09:47.107 2009   (  2.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:47.957 2009  to  Sat Jun 13 05:09:47.957 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  45  FAILED    PMC        VxInterface.packetReadError                                   Sat Jun 13 05:09:48.008 2009  to  Sat Jun 13 05:09:48.008 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

  46  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:48.360 2009  to  Sat Jun 13 05:09:48.360 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  47  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:48.712 2009  to  Sat Jun 13 05:09:48.712 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  48  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jun 13 05:09:49.063 2009  to  Sat Jun 13 05:09:49.063 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  49  FAILED    PMC        VxInterface.lengthError                                       Sat Jun 13 05:12:46.780 2009  to  Sat Jun 13 05:12:46.780 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.close                                             Sat Jun 13 05:12:46.831 2009  to  Sat Jun 13 05:12:46.831 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  51  FAILED    IIF        command.sendWavefront                                         Sat Jun 13 05:28:19.579 2009  to  Sat Jun 13 05:28:26.360 2009   (  6.78) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  52  FAILED    PSF        command.setZernikes                                           Sat Jun 13 05:28:19.635 2009  to  Sat Jun 13 05:28:26.252 2009   (  6.62) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  53  FAILED    PSF        command.applyZernikes                                         Sat Jun 13 05:28:19.685 2009  to  Sat Jun 13 05:28:26.201 2009   (  6.52) secs
                     right PSF ApplyZernikes failed

  54  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Jun 13 05:28:19.840 2009  to  Sat Jun 13 05:28:26.150 2009   (  6.31) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:28:23.989 2009  to  Sat Jun 13 05:28:26.042 2009   (  2.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:28:23.935 2009  to  Sat Jun 13 05:28:26.099 2009   (  2.16) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  57  FAILED    PSF        command.setInstrumentOffsets                                  Sat Jun 13 05:31:29.576 2009  to  Sat Jun 13 05:31:37.965 2009   (  8.39) secs
                     right PSF SetInstrumentOffsets failed

  58  FAILED    IIF        command.moveFocus                                             Sat Jun 13 05:31:29.519 2009  to  Sat Jun 13 05:31:38.125 2009   (  8.61) secs
                     IIF GetTrajectory command started for right LBC, start time 5.499523019675926e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.400000000000000e-01

  59  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Jun 13 05:31:29.626 2009  to  Sat Jun 13 05:31:37.911 2009   (  8.28) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  60  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Jun 13 05:31:29.732 2009  to  Sat Jun 13 05:31:37.794 2009   (  8.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Jun 13 05:31:29.676 2009  to  Sat Jun 13 05:31:37.856 2009   (  8.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Jun 13 03:19:29.972 2009  to  Sat Jun 13 03:19:29.972 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  63  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sat Jun 13 04:54:23.721 2009  to  Sat Jun 13 04:54:23.721 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:14:43.218 2009  to  Sat Jun 13 05:14:43.218 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:16:49.764 2009  to  Sat Jun 13 05:16:49.764 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:17:10.259 2009  to  Sat Jun 13 05:17:10.259 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jun 13 05:25:44.202 2009  to  Sat Jun 13 05:25:44.202 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

**********************************************************
    Reporting period ending:   Sat Jun 13 05:25:44.202 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback