You are here: Foswiki>Software Web>TCSSWReportFile_090603 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jun 3 2009 to Jun 4 2009
 
    Reporting period beginning:   Wed Jun  3 18:53:00.530 2009
    Reporting period ending:      Thu Jun  4 05:41:59.854 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.04    0.12   100.0 %        133        133                      
                                                                       0.01    0.05    0.04    0.12
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.31    0.76    0.23    1.50   100.0 %        313        313                      
                                                                       0.31    0.76    0.23    1.50
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.38    5.72    0.00   27.59    99.5 %        418        416          2           
                                                                       4.37    5.73    2.51   27.59
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   32.42   21.85    0.00  118.11    90.5 %         21         19          2           
                                                                      36.11   27.70    1.25  118.11
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   21.70   11.22    0.00   87.21   100.0 %         21         21                      
                                                                      22.11   11.78    1.05   87.21
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   21.06    8.86    0.00   91.21   100.0 %         19         19                      
                                                                      22.09    9.90    2.06   91.21
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    4.01    9.34    5.58   36.93   100.0 %        129        129                      
                                                                       4.01    9.34    5.58   36.93
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.44    3.56    2.52    6.60   100.0 %         18         18                      
                                                                       1.44    3.56    2.52    6.60

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             6

IIF Events of Interest

   1  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 20:39:51.347 2009  to  Wed Jun  3 20:40:38.431 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

   2  SEQERROR  IIF        command.preset.elevationWait                                  Wed Jun  3 20:39:52.187 2009  to  Wed Jun  3 20:40:40.646 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

   3  FAILED    IIF        command.preset.(TRACK)                                        Wed Jun  3 20:40:38.431 2009  to  Wed Jun  3 20:41:13.242 2009   ( 34.81) secs
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

   4  SEQERROR  IIF        command.preset.elevationWait                                  Wed Jun  3 20:41:12.762 2009  to  Wed Jun  3 20:41:12.762 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for elevation complete for both LBC

   5  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 20:42:25.962 2009  to  Wed Jun  3 20:42:25.962 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

   6  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 23:33:38.069 2009  to  Wed Jun  3 23:35:35.575 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

   7  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 23:35:45.391 2009  to  Wed Jun  3 23:35:45.391 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

   8  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 00:31:22.627 2009  to  Thu Jun  4 00:33:27.157 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

   9  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 00:31:35.405 2009  to  Thu Jun  4 00:33:35.362 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for both LBC

  10  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 00:33:41.694 2009  to  Thu Jun  4 00:33:41.694 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for telescope complete for both LBC

  11  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 00:33:41.750 2009  to  Thu Jun  4 00:33:41.750 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  12  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 01:26:17.035 2009  to  Thu Jun  4 01:27:19.930 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  13  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 01:26:43.659 2009  to  Thu Jun  4 01:27:28.586 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for both LBC

  14  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 01:28:59.970 2009  to  Thu Jun  4 01:28:59.970 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for telescope complete for both LBC

  15  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 01:29:00.024 2009  to  Thu Jun  4 01:29:00.024 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  16  FAILED    IIF        command.preset.(TRACK)                                        Thu Jun  4 01:47:34.721 2009  to  Thu Jun  4 01:47:43.355 2009   (  8.63) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  17  FAILED    IIF        command.moveFocus                                             Thu Jun  4 01:59:46.881 2009  to  Thu Jun  4 01:59:58.535 2009   ( 11.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.498637489583333e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 4.900000000000000e-02

  18  FAILED    IIF        command.moveFocus                                             Thu Jun  4 02:15:14.481 2009  to  Thu Jun  4 02:15:21.133 2009   (  6.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.498638557870370e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.700000000000000e-01

  19  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:31:40.511 2009  to  Thu Jun  4 04:31:41.200 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for -5.000000000000000e-02

  20  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:31:51.530 2009  to  Thu Jun  4 04:31:51.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for right LBC for -5.000000000000000e-02

  21  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:32:47.214 2009  to  Thu Jun  4 04:32:47.745 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for -5.000000000000000e-02

  22  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:32:59.188 2009  to  Thu Jun  4 04:32:59.188 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for right LBC for -5.000000000000000e-02
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3448                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6896                      
                                                                                                   
     lights.command.disable . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** plc.read.failed. . . . . . . . . . . . . . . . . . . . . . . .              41636           
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      93                      

ECS Events of Interest

   1  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:00.530 2009  to  Wed Jun  3 18:53:00.530 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   2  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:01.476 2009  to  Wed Jun  3 18:53:01.476 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   3  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:02.380 2009  to  Wed Jun  3 18:53:02.380 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   4  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:03.327 2009  to  Wed Jun  3 18:53:03.327 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   5  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:04.217 2009  to  Wed Jun  3 18:53:04.217 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   6  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:05.143 2009  to  Wed Jun  3 18:53:05.143 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   7  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:06.046 2009  to  Wed Jun  3 18:53:06.046 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   8  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:06.970 2009  to  Wed Jun  3 18:53:06.970 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   9  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:07.896 2009  to  Wed Jun  3 18:53:07.896 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  10  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:08.798 2009  to  Wed Jun  3 18:53:08.798 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  11  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:09.690 2009  to  Wed Jun  3 18:53:09.690 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  12  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:10.701 2009  to  Wed Jun  3 18:53:10.701 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  13  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:11.636 2009  to  Wed Jun  3 18:53:11.636 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  14  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:12.518 2009  to  Wed Jun  3 18:53:12.518 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  15  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:13.464 2009  to  Wed Jun  3 18:53:13.464 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  16  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:14.379 2009  to  Wed Jun  3 18:53:14.379 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  17  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:15.282 2009  to  Wed Jun  3 18:53:15.282 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  18  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:16.219 2009  to  Wed Jun  3 18:53:16.219 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  19  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:17.165 2009  to  Wed Jun  3 18:53:17.165 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  20  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:18.057 2009  to  Wed Jun  3 18:53:18.057 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  21  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:18.939 2009  to  Wed Jun  3 18:53:18.939 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  22  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:19.798 2009  to  Wed Jun  3 18:53:19.798 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  23  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:20.690 2009  to  Wed Jun  3 18:53:20.690 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  24  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:21.670 2009  to  Wed Jun  3 18:53:21.670 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  25  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:22.571 2009  to  Wed Jun  3 18:53:22.571 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       9                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             6
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      34                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            20
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      42                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      48                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     162                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      54                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest
      Nothing to report
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].tertiary_mirror.getfocalstationcount.command . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     side[0].tertiary_mirror.init.command . . . . . . . . . . . . .    0.00  125.28  125.28  125.28   100.0 %          1          1                      
                                                                       0.00  125.28  125.28  125.28
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.00   38.85   38.85   38.85   100.0 %          1          1                      
                                                                       0.00   38.85   38.85   38.85

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest

   1  SHUTDOWN  OSS        shutdown                                                      Wed Jun  3 18:58:57.748 2009  to  Wed Jun  3 18:58:57.748 2009   (  0.00) secs
                     The oss was shut down.

   2  STARTUP   OSS        startup                                                       Wed Jun  3 18:59:12.626 2009  to  Wed Jun  3 18:59:12.626 2009   (  0.00) secs
                     The oss was started.

   3  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Wed Jun  3 18:59:50.969 2009  to  Wed Jun  3 18:59:50.969 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

   4  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Wed Jun  3 18:59:54.082 2009  to  Wed Jun  3 18:59:54.082 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.09    0.24    0.11    0.67   100.0 %        313        313                      
                                                                       0.09    0.24    0.11    0.67
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.06   100.0 %          8          8                      
                                                                       0.01    0.05    0.04    0.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.24    0.19    0.05    0.78   100.0 %         21         21                      
                                                                       0.24    0.19    0.05    0.78
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.23    0.60    0.31    1.07   100.0 %         21         21                      
                                                                       0.23    0.60    0.31    1.07

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.68    2.49    2.05    6.07   100.0 %        129        129                      
                                                                       0.68    2.49    2.05    6.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.71    2.56    2.06    3.06   100.0 %          2          2                      
                                                                       0.71    2.56    2.06    3.06
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.76    5.29    0.00   42.14    99.0 %        608        602          6           
                                                                       4.77    5.31    2.05   42.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           134
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 13           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 13           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      13                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     129                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            24
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      50                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      50                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 19:53:01.394 2009  to  Wed Jun  3 19:53:04.453 2009   (  3.06) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.515 2009  to  Wed Jun  3 20:41:12.881 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

   3  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.528 2009  to  Wed Jun  3 20:41:12.897 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.881 2009  to  Wed Jun  3 20:41:12.934 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.897 2009  to  Wed Jun  3 20:41:12.949 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:31.608 2009  to  Wed Jun  3 20:41:31.608 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   7  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:42:13.697 2009  to  Wed Jun  3 20:42:13.697 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

   8  FAILED    PMC        VxInterface.close                                             Wed Jun  3 21:32:23.272 2009  to  Wed Jun  3 21:32:23.272 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   9  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 21:32:23.220 2009  to  Wed Jun  3 21:32:23.220 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 21:47:37.827 2009  to  Wed Jun  3 21:47:37.827 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Wed Jun  3 21:47:37.879 2009  to  Wed Jun  3 21:47:37.879 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.close                                             Wed Jun  3 23:42:07.922 2009  to  Wed Jun  3 23:42:07.922 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 23:42:07.870 2009  to  Wed Jun  3 23:42:07.870 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 00:24:59.873 2009  to  Thu Jun  4 00:24:59.873 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Thu Jun  4 00:24:59.926 2009  to  Thu Jun  4 00:24:59.926 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 00:37:01.294 2009  to  Thu Jun  4 00:37:01.294 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.close                                             Thu Jun  4 00:37:01.346 2009  to  Thu Jun  4 00:37:01.346 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.packetReadError                                   Thu Jun  4 00:42:24.439 2009  to  Thu Jun  4 00:42:24.439 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  19  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jun  4 00:42:24.387 2009  to  Thu Jun  4 00:42:24.387 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  20  FAILED    PMC        thermal.badReceive                                            Thu Jun  4 00:42:24.492 2009  to  Thu Jun  4 00:42:24.492 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  21  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 01:01:03.740 2009  to  Thu Jun  4 01:01:03.740 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Thu Jun  4 01:01:03.792 2009  to  Thu Jun  4 01:01:03.792 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.close                                             Thu Jun  4 01:31:50.304 2009  to  Thu Jun  4 01:31:50.304 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 01:31:50.255 2009  to  Thu Jun  4 01:31:50.255 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 01:47:37.044 2009  to  Thu Jun  4 01:47:43.108 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  26  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 01:59:47.110 2009  to  Thu Jun  4 01:59:58.183 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:03:33.061 2009  to  Thu Jun  4 02:03:33.061 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  28  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:03:33.113 2009  to  Thu Jun  4 02:03:33.113 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  29  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:11:52.736 2009  to  Thu Jun  4 02:11:52.736 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:11:52.684 2009  to  Thu Jun  4 02:11:52.684 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 02:15:14.710 2009  to  Thu Jun  4 02:15:20.774 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  32  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:35:55.861 2009  to  Thu Jun  4 02:35:55.861 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:35:55.912 2009  to  Thu Jun  4 02:35:55.912 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 03:16:16.188 2009  to  Thu Jun  4 03:16:16.188 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  35  FAILED    PMC        VxInterface.close                                             Thu Jun  4 03:16:16.240 2009  to  Thu Jun  4 03:16:16.240 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 03:39:40.885 2009  to  Thu Jun  4 03:39:40.885 2009   (  0.00) secs
                     right PMC Mirror length error: expected 92, got 96

  37  FAILED    PMC        VxInterface.close                                             Thu Jun  4 03:39:40.937 2009  to  Thu Jun  4 03:39:40.937 2009   (  0.00) secs
                     right PMC Mirror closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 04:30:42.208 2009  to  Thu Jun  4 04:30:42.208 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  39  FAILED    PMC        VxInterface.close                                             Thu Jun  4 04:30:42.273 2009  to  Thu Jun  4 04:30:42.273 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.01    9.09    5.33   36.69   100.0 %        129        129                      
                                                                       4.01    9.09    5.33   36.69
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.08   100.0 %         42         42                      
                                                                       0.00    0.05    0.05    0.08
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.32    5.49    0.00   27.46    99.5 %        436        434          2           
                                                                       4.31    5.50    2.39   27.46
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.01    9.20    5.43   36.80   100.0 %        129        129                      
                                                                       4.01    9.20    5.43   36.80
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.01    8.86    5.11   36.47   100.0 %        129        129                      
                                                                       4.01    8.86    5.11   36.47
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.76    5.46    0.00   42.26    99.0 %        608        602          6           
                                                                       4.76    5.49    2.18   42.26
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          1          1                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.70    2.70    2.20    3.19   100.0 %          2          2                      
                                                                       0.70    2.70    2.20    3.19
     primaryMirror.command.clearPositions . . . . . . . . . . . . .    0.00    3.30    3.30    3.30     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.09    0.13    0.06    1.05   100.0 %        313        313                      
                                                                       0.09    0.13    0.06    1.05
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.30    5.40    2.28   27.35    99.5 %        436        434          2           
                                                                       4.30    5.38    2.28   27.35
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.04    0.10   100.0 %        129        129                      
                                                                       0.01    0.06    0.04    0.10

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1876           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 19:53:01.327 2009  to  Wed Jun  3 19:53:04.517 2009   (  3.19) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.clearPositions                          Wed Jun  3 19:53:01.273 2009  to  Wed Jun  3 19:53:04.572 2009   (  3.30) secs
                     right PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

   3  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.451 2009  to  Wed Jun  3 20:41:12.821 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   4  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.459 2009  to  Wed Jun  3 20:41:12.827 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.821 2009  to  Wed Jun  3 20:41:13.003 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.827 2009  to  Wed Jun  3 20:41:13.015 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:31.670 2009  to  Wed Jun  3 20:41:31.670 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   8  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:42:13.762 2009  to  Wed Jun  3 20:42:13.762 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   9  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 20:56:17.306 2009  to  Wed Jun  3 20:56:17.306 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.4155330e-03 -1.5866160e-03 -9.4980001e-04 -4.7048569e-02 1.5423584e-01 -5.2060425e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 20:56:17.560 2009  to  Wed Jun  3 20:56:17.560 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.4155330e-03 -1.5866160e-03 -9.4980001e-04 -4.7048569e-02 1.5423584e-01 -5.2060425e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:21.856 2009  to  Wed Jun  3 21:01:21.856 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:22.110 2009  to  Wed Jun  3 21:01:22.110 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:22.364 2009  to  Wed Jun  3 21:01:22.364 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:02:10.479 2009  to  Wed Jun  3 21:02:10.479 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:02:10.733 2009  to  Wed Jun  3 21:02:10.733 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:10:54.437 2009  to  Wed Jun  3 21:10:54.437 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:10:54.692 2009  to  Wed Jun  3 21:10:54.692 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:20.263 2009  to  Wed Jun  3 21:14:20.263 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:20.520 2009  to  Wed Jun  3 21:14:20.520 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.308 2009  to  Wed Jun  3 21:14:34.308 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.562 2009  to  Wed Jun  3 21:14:34.562 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.817 2009  to  Wed Jun  3 21:14:34.817 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:16:37.733 2009  to  Wed Jun  3 21:16:37.733 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:16:37.989 2009  to  Wed Jun  3 21:16:37.989 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:14.359 2009  to  Wed Jun  3 21:17:14.359 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:14.614 2009  to  Wed Jun  3 21:17:14.614 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:18.302 2009  to  Wed Jun  3 21:17:18.302 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1459589e-03 -1.4023632e-03 -3.2595396e-03 -2.7800560e-02 7.8598022e-02 4.3414593e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:26.845 2009  to  Wed Jun  3 21:17:26.845 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:27.128 2009  to  Wed Jun  3 21:17:27.128 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:29.405 2009  to  Wed Jun  3 21:17:29.405 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1459589e-03 -1.4023632e-03 -3.2595396e-03 -2.7800560e-02 7.8598022e-02 4.3414593e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:33.326 2009  to  Wed Jun  3 21:17:33.326 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:33.581 2009  to  Wed Jun  3 21:17:33.581 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:34.922 2009  to  Wed Jun  3 21:17:34.922 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.3719806e-03 -1.5224367e-03 -1.5485287e-03 -1.9454956e-04 1.5042496e-01 -6.5186083e-02

  34  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 01:47:36.979 2009  to  Thu Jun  4 01:47:43.176 2009   (  6.20) secs
                     right PSF adjusting primary mirror forces
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  35  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jun  4 01:59:46.944 2009  to  Thu Jun  4 01:59:58.366 2009   ( 11.42) secs
                     right PSF SetInstrumentOffsets failed

  36  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jun  4 01:59:46.996 2009  to  Thu Jun  4 01:59:58.308 2009   ( 11.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 01:59:47.048 2009  to  Thu Jun  4 01:59:58.252 2009   ( 11.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jun  4 02:15:14.544 2009  to  Thu Jun  4 02:15:20.956 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  39  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 02:15:14.648 2009  to  Thu Jun  4 02:15:20.845 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  40  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jun  4 02:15:14.596 2009  to  Thu Jun  4 02:15:20.901 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  41  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:31:40.573 2009  to  Thu Jun  4 04:31:41.288 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

  42  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:31:51.404 2009  to  Thu Jun  4 04:31:51.404 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete

  43  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:32:47.279 2009  to  Thu Jun  4 04:32:47.806 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

  44  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:32:59.122 2009  to  Thu Jun  4 04:32:59.122 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:00.530 2009  to  Wed Jun  3 18:53:00.530 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   2  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:01.476 2009  to  Wed Jun  3 18:53:01.476 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   3  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:02.380 2009  to  Wed Jun  3 18:53:02.380 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   4  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:03.327 2009  to  Wed Jun  3 18:53:03.327 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   5  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:04.217 2009  to  Wed Jun  3 18:53:04.217 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   6  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:05.143 2009  to  Wed Jun  3 18:53:05.143 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   7  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:06.046 2009  to  Wed Jun  3 18:53:06.046 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   8  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:06.970 2009  to  Wed Jun  3 18:53:06.970 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

   9  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:07.896 2009  to  Wed Jun  3 18:53:07.896 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  10  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:08.798 2009  to  Wed Jun  3 18:53:08.798 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  11  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:09.690 2009  to  Wed Jun  3 18:53:09.690 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  12  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:10.701 2009  to  Wed Jun  3 18:53:10.701 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  13  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:11.636 2009  to  Wed Jun  3 18:53:11.636 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  14  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:12.518 2009  to  Wed Jun  3 18:53:12.518 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  15  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:13.464 2009  to  Wed Jun  3 18:53:13.464 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  16  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:14.379 2009  to  Wed Jun  3 18:53:14.379 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  17  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:15.282 2009  to  Wed Jun  3 18:53:15.282 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  18  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:16.219 2009  to  Wed Jun  3 18:53:16.219 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  19  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:17.165 2009  to  Wed Jun  3 18:53:17.165 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  20  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:18.057 2009  to  Wed Jun  3 18:53:18.057 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  21  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:18.939 2009  to  Wed Jun  3 18:53:18.939 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  22  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:19.798 2009  to  Wed Jun  3 18:53:19.798 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  23  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:20.690 2009  to  Wed Jun  3 18:53:20.690 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  24  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:21.670 2009  to  Wed Jun  3 18:53:21.670 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  25  FAILED    ECS        plc.read.failed                                               Wed Jun  3 18:53:22.571 2009  to  Wed Jun  3 18:53:22.571 2009   (  0.00) secs
                     ECS PLC read failed because Could Not Read the Following Tags: :Rack5:9:O

  26  SHUTDOWN  OSS        shutdown                                                      Wed Jun  3 18:58:57.748 2009  to  Wed Jun  3 18:58:57.748 2009   (  0.00) secs
                     The oss was shut down.

  27  STARTUP   OSS        startup                                                       Wed Jun  3 18:59:12.626 2009  to  Wed Jun  3 18:59:12.626 2009   (  0.00) secs
                     The oss was started.

  28  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Wed Jun  3 18:59:50.969 2009  to  Wed Jun  3 18:59:50.969 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

  29  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Wed Jun  3 18:59:54.082 2009  to  Wed Jun  3 18:59:54.082 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 19:53:01.327 2009  to  Wed Jun  3 19:53:04.517 2009   (  3.19) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  31  FAILED    PSF        primaryMirror.command.clearPositions                          Wed Jun  3 19:53:01.273 2009  to  Wed Jun  3 19:53:04.572 2009   (  3.30) secs
                     right PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

  32  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 19:53:01.394 2009  to  Wed Jun  3 19:53:04.453 2009   (  3.06) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  33  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 20:39:51.347 2009  to  Wed Jun  3 20:40:38.431 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  34  SEQERROR  IIF        command.preset.elevationWait                                  Wed Jun  3 20:39:52.187 2009  to  Wed Jun  3 20:40:40.646 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

  35  FAILED    IIF        command.preset.(TRACK)                                        Wed Jun  3 20:40:38.431 2009  to  Wed Jun  3 20:41:13.242 2009   ( 34.81) secs
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

  36  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.451 2009  to  Wed Jun  3 20:41:12.821 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  37  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.459 2009  to  Wed Jun  3 20:41:12.827 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  38  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.515 2009  to  Wed Jun  3 20:41:12.881 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  39  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.528 2009  to  Wed Jun  3 20:41:12.897 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  SEQERROR  IIF        command.preset.elevationWait                                  Wed Jun  3 20:41:12.762 2009  to  Wed Jun  3 20:41:12.762 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for elevation complete for both LBC

  41  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.881 2009  to  Wed Jun  3 20:41:12.934 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  42  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:12.897 2009  to  Wed Jun  3 20:41:12.949 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  43  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.821 2009  to  Wed Jun  3 20:41:13.003 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  44  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:12.827 2009  to  Wed Jun  3 20:41:13.015 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  45  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:41:31.608 2009  to  Wed Jun  3 20:41:31.608 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  46  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:41:31.670 2009  to  Wed Jun  3 20:41:31.670 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  47  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Jun  3 20:42:13.697 2009  to  Wed Jun  3 20:42:13.697 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  48  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Jun  3 20:42:13.762 2009  to  Wed Jun  3 20:42:13.762 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  49  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 20:42:25.962 2009  to  Wed Jun  3 20:42:25.962 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  50  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 20:56:17.306 2009  to  Wed Jun  3 20:56:17.306 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.4155330e-03 -1.5866160e-03 -9.4980001e-04 -4.7048569e-02 1.5423584e-01 -5.2060425e-02

  51  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 20:56:17.560 2009  to  Wed Jun  3 20:56:17.560 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.4155330e-03 -1.5866160e-03 -9.4980001e-04 -4.7048569e-02 1.5423584e-01 -5.2060425e-02

  52  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:21.856 2009  to  Wed Jun  3 21:01:21.856 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  53  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:22.110 2009  to  Wed Jun  3 21:01:22.110 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  54  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:01:22.364 2009  to  Wed Jun  3 21:01:22.364 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.0958688e-03 -1.5781522e-03 -7.6597929e-04 -2.2678375e-03 1.6423798e-01 -6.2472671e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:02:10.479 2009  to  Wed Jun  3 21:02:10.479 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:02:10.733 2009  to  Wed Jun  3 21:02:10.733 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  57  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:10:54.437 2009  to  Wed Jun  3 21:10:54.437 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  58  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:10:54.692 2009  to  Wed Jun  3 21:10:54.692 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7554881e-03 -1.5788376e-03 -1.1333227e-03 -2.4721146e-02 1.5946960e-01 -4.1664898e-02

  59  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:20.263 2009  to  Wed Jun  3 21:14:20.263 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  60  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:20.520 2009  to  Wed Jun  3 21:14:20.520 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  61  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.308 2009  to  Wed Jun  3 21:14:34.308 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  62  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.562 2009  to  Wed Jun  3 21:14:34.562 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  63  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:14:34.817 2009  to  Wed Jun  3 21:14:34.817 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  64  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:16:37.733 2009  to  Wed Jun  3 21:16:37.733 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  65  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:16:37.989 2009  to  Wed Jun  3 21:16:37.989 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  66  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:14.359 2009  to  Wed Jun  3 21:17:14.359 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:14.614 2009  to  Wed Jun  3 21:17:14.614 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  68  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:18.302 2009  to  Wed Jun  3 21:17:18.302 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1459589e-03 -1.4023632e-03 -3.2595396e-03 -2.7800560e-02 7.8598022e-02 4.3414593e-02

  69  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:26.845 2009  to  Wed Jun  3 21:17:26.845 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  70  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:27.128 2009  to  Wed Jun  3 21:17:27.128 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3159513e-03 -1.7129332e-03 -3.0685067e-03 -3.4704685e-02 5.5740356e-02 3.2591820e-02

  71  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:29.405 2009  to  Wed Jun  3 21:17:29.405 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1459589e-03 -1.4023632e-03 -3.2595396e-03 -2.7800560e-02 7.8598022e-02 4.3414593e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:33.326 2009  to  Wed Jun  3 21:17:33.326 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  73  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:33.581 2009  to  Wed Jun  3 21:17:33.581 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9989433e-04 -1.3944283e-03 -3.0726790e-03 -5.0706863e-03 8.3923340e-02 3.2830715e-02

  74  FAILED    PSF        primaryMirror.positionError                                   Wed Jun  3 21:17:34.922 2009  to  Wed Jun  3 21:17:34.922 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.3719806e-03 -1.5224367e-03 -1.5485287e-03 -1.9454956e-04 1.5042496e-01 -6.5186083e-02

  75  FAILED    PMC        VxInterface.close                                             Wed Jun  3 21:32:23.272 2009  to  Wed Jun  3 21:32:23.272 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 21:32:23.220 2009  to  Wed Jun  3 21:32:23.220 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 21:47:37.827 2009  to  Wed Jun  3 21:47:37.827 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  78  FAILED    PMC        VxInterface.close                                             Wed Jun  3 21:47:37.879 2009  to  Wed Jun  3 21:47:37.879 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  79  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 23:33:38.069 2009  to  Wed Jun  3 23:35:35.575 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  80  SEQERROR  IIF        command.preset.(TRACK)                                        Wed Jun  3 23:35:45.391 2009  to  Wed Jun  3 23:35:45.391 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  81  FAILED    PMC        VxInterface.close                                             Wed Jun  3 23:42:07.922 2009  to  Wed Jun  3 23:42:07.922 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Wed Jun  3 23:42:07.870 2009  to  Wed Jun  3 23:42:07.870 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  83  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 00:24:59.873 2009  to  Thu Jun  4 00:24:59.873 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  84  FAILED    PMC        VxInterface.close                                             Thu Jun  4 00:24:59.926 2009  to  Thu Jun  4 00:24:59.926 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  85  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 00:31:22.627 2009  to  Thu Jun  4 00:33:27.157 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  86  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 00:31:35.405 2009  to  Thu Jun  4 00:33:35.362 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for both LBC

  87  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 00:33:41.694 2009  to  Thu Jun  4 00:33:41.694 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for telescope complete for both LBC

  88  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 00:33:41.750 2009  to  Thu Jun  4 00:33:41.750 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

  89  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 00:37:01.294 2009  to  Thu Jun  4 00:37:01.294 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  90  FAILED    PMC        VxInterface.close                                             Thu Jun  4 00:37:01.346 2009  to  Thu Jun  4 00:37:01.346 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  91  FAILED    PMC        VxInterface.packetReadError                                   Thu Jun  4 00:42:24.439 2009  to  Thu Jun  4 00:42:24.439 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  92  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jun  4 00:42:24.387 2009  to  Thu Jun  4 00:42:24.387 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  93  FAILED    PMC        thermal.badReceive                                            Thu Jun  4 00:42:24.492 2009  to  Thu Jun  4 00:42:24.492 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  94  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 01:01:03.740 2009  to  Thu Jun  4 01:01:03.740 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  95  FAILED    PMC        VxInterface.close                                             Thu Jun  4 01:01:03.792 2009  to  Thu Jun  4 01:01:03.792 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  96  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 01:26:17.035 2009  to  Thu Jun  4 01:27:19.930 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  97  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 01:26:43.659 2009  to  Thu Jun  4 01:27:28.586 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for both LBC

  98  SEQERROR  IIF        command.preset.telescopeWait                                  Thu Jun  4 01:28:59.970 2009  to  Thu Jun  4 01:28:59.970 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for telescope complete for both LBC

  99  SEQERROR  IIF        command.preset.(TRACK)                                        Thu Jun  4 01:29:00.024 2009  to  Thu Jun  4 01:29:00.024 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command complete for both LBC mode TRACK from IIF

 100  FAILED    PMC        VxInterface.close                                             Thu Jun  4 01:31:50.304 2009  to  Thu Jun  4 01:31:50.304 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 101  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 01:31:50.255 2009  to  Thu Jun  4 01:31:50.255 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 102  FAILED    IIF        command.preset.(TRACK)                                        Thu Jun  4 01:47:34.721 2009  to  Thu Jun  4 01:47:43.355 2009   (  8.63) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

 103  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 01:47:36.979 2009  to  Thu Jun  4 01:47:43.176 2009   (  6.20) secs
                     right PSF adjusting primary mirror forces
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 104  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 01:47:37.044 2009  to  Thu Jun  4 01:47:43.108 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 105  FAILED    IIF        command.moveFocus                                             Thu Jun  4 01:59:46.881 2009  to  Thu Jun  4 01:59:58.535 2009   ( 11.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.498637489583333e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 4.900000000000000e-02

 106  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jun  4 01:59:46.944 2009  to  Thu Jun  4 01:59:58.366 2009   ( 11.42) secs
                     right PSF SetInstrumentOffsets failed

 107  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jun  4 01:59:46.996 2009  to  Thu Jun  4 01:59:58.308 2009   ( 11.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 108  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 01:59:47.048 2009  to  Thu Jun  4 01:59:58.252 2009   ( 11.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 109  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 01:59:47.110 2009  to  Thu Jun  4 01:59:58.183 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 110  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:03:33.061 2009  to  Thu Jun  4 02:03:33.061 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 111  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:03:33.113 2009  to  Thu Jun  4 02:03:33.113 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 112  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:11:52.736 2009  to  Thu Jun  4 02:11:52.736 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 113  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:11:52.684 2009  to  Thu Jun  4 02:11:52.684 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 114  FAILED    IIF        command.moveFocus                                             Thu Jun  4 02:15:14.481 2009  to  Thu Jun  4 02:15:21.133 2009   (  6.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.498638557870370e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.700000000000000e-01

 115  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jun  4 02:15:14.544 2009  to  Thu Jun  4 02:15:20.956 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 116  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jun  4 02:15:14.648 2009  to  Thu Jun  4 02:15:20.845 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 117  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jun  4 02:15:14.596 2009  to  Thu Jun  4 02:15:20.901 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 118  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jun  4 02:15:14.710 2009  to  Thu Jun  4 02:15:20.774 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 119  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 02:35:55.861 2009  to  Thu Jun  4 02:35:55.861 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 120  FAILED    PMC        VxInterface.close                                             Thu Jun  4 02:35:55.912 2009  to  Thu Jun  4 02:35:55.912 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 121  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 03:16:16.188 2009  to  Thu Jun  4 03:16:16.188 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 122  FAILED    PMC        VxInterface.close                                             Thu Jun  4 03:16:16.240 2009  to  Thu Jun  4 03:16:16.240 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 123  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 03:39:40.885 2009  to  Thu Jun  4 03:39:40.885 2009   (  0.00) secs
                     right PMC Mirror length error: expected 92, got 96

 124  FAILED    PMC        VxInterface.close                                             Thu Jun  4 03:39:40.937 2009  to  Thu Jun  4 03:39:40.937 2009   (  0.00) secs
                     right PMC Mirror closing network connection

 125  FAILED    PMC        VxInterface.lengthError                                       Thu Jun  4 04:30:42.208 2009  to  Thu Jun  4 04:30:42.208 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

 126  FAILED    PMC        VxInterface.close                                             Thu Jun  4 04:30:42.273 2009  to  Thu Jun  4 04:30:42.273 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 127  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:31:40.511 2009  to  Thu Jun  4 04:31:41.200 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for -5.000000000000000e-02

 128  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:31:40.573 2009  to  Thu Jun  4 04:31:41.288 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

 129  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:31:51.404 2009  to  Thu Jun  4 04:31:51.404 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete

 130  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:31:51.530 2009  to  Thu Jun  4 04:31:51.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for right LBC for -5.000000000000000e-02

 131  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:32:47.214 2009  to  Thu Jun  4 04:32:47.745 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for -5.000000000000000e-02

 132  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:32:47.279 2009  to  Thu Jun  4 04:32:47.806 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

 133  SEQERROR  PSF        command.setInstrumentOffsets                                  Thu Jun  4 04:32:59.122 2009  to  Thu Jun  4 04:32:59.122 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete

 134  SEQERROR  IIF        command.moveFocus                                             Thu Jun  4 04:32:59.188 2009  to  Thu Jun  4 04:32:59.188 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for right LBC for -5.000000000000000e-02

**********************************************************
    Reporting period ending:   Thu Jun  4 05:41:59.854 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback