You are here: Foswiki>Software Web>TCSSWReportFile_090525 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 25 2009 to May 26 2009
 
    Reporting period beginning:   Mon May 25 18:48:04.478 2009
    Reporting period ending:      Tue May 26 05:44:56.132 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .  391.61  339.93    0.38  679.11    50.0 %          4          2          2           
                                                                       0.57    0.79    0.38    1.20

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 26 01:22:58.346 2009  to  Tue May 26 01:34:17.456 2009   (679.11) secs
                     IIF TCS authorize command failed for left LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 26 01:22:58.361 2009  to  Tue May 26 01:34:17.402 2009   (679.04) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for left LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for right LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for left LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         40         40                      
                                                                       0.00    0.05    0.05    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    4.62    0.79    0.00   46.93   100.0 %        102        102                      
                                                                       4.68    0.82    0.24   46.93
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.02    0.19    0.17    0.26   100.0 %         74         74                      
                                                                       0.02    0.19    0.17    0.26
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .   13.25    7.85    2.54  122.98    98.0 %         98         96          2           
                                                                       6.19    6.65    2.54   37.67
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.62    4.66    2.86    7.66   100.0 %         11         11                      
                                                                       1.62    4.66    2.86    7.66
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.67    3.95    2.05    7.06   100.0 %         11         11                      
                                                                       1.67    3.95    2.05    7.06
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   27.50   22.23    0.00   62.30    66.7 %          6          2          2          2
                                                                       3.04   13.30   11.15   15.45
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   31.25   27.65    1.26   69.18   100.0 %          4          4                      
                                                                      31.25   27.65    1.26   69.18
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   38.09   22.10    2.07   79.19   100.0 %          4          4                      
                                                                      38.09   22.10    2.07   79.19
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    6.33    6.57    0.64   48.52   100.0 %        124        124                      
                                                                       6.33    6.57    0.64   48.52
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.29    4.07    2.55    6.56   100.0 %         21         21                      
                                                                       1.29    4.07    2.55    6.56

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             8

IIF Events of Interest

   1  SEQERROR  IIF        command.preset.(TRACK)                                        Tue May 26 01:31:34.159 2009  to  Tue May 26 01:33:14.947 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

   2  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:31:36.210 2009  to  Tue May 26 01:32:17.684 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735575231481e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   3  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:32:17.684 2009  to  Tue May 26 01:33:17.002 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735643518518e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   4  FAILED    IIF        command.preset.(TRACK)                                        Tue May 26 01:33:14.947 2009  to  Tue May 26 01:34:17.249 2009   ( 62.30) secs
                     IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset command failed for both LBC mode TRACK from IIF

   5  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:33:17.002 2009  to  Tue May 26 01:33:30.196 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735659722222e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   6  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.126 2009  to  Tue May 26 01:34:17.126 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735575231481e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   7  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.127 2009  to  Tue May 26 01:34:17.127 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735659722222e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   8  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.128 2009  to  Tue May 26 01:34:17.128 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735643518518e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

   9  SEQERROR  IIF        command.preset.(TRACK)                                        Tue May 26 01:34:17.251 2009  to  Tue May 26 01:34:17.251 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for both LBC mode TRACK from IIF

  10  FAILED    IIF        command.moveFocus                                             Tue May 26 03:56:24.234 2009  to  Tue May 26 03:58:27.209 2009   (122.98) secs
                     IIF GetTrajectory command started for both LBC, start time 5.497745584490741e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  11  FAILED    IIF        command.moveFocus                                             Tue May 26 04:21:56.622 2009  to  Tue May 26 04:22:04.290 2009   (  7.67) secs
                     IIF MoveFocus command started for right LBC for 1.390000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3279                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6558                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    41                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    29                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     176                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            74
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      38                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      57                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      16                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            17
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             8
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      62                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      10                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 16           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.stowpinCommandRejected . . . . . . . . . . . . .                  2           
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.OpticalSupport.commandActionReceived . . . . . . . . . .       2                      
     MCSPU.Side.doingCommand. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Side.completedCommand. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.OpticalSupport.commandReceived . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.startingRetract . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.commandCompletion . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      42                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     102                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      34                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      12                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 00:53:19.905 2009  to  Tue May 26 00:53:19.905 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 00:53:19.914 2009  to  Tue May 26 00:53:19.914 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue May 26 00:53:20.012 2009  to  Tue May 26 00:53:20.012 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.025 2009  to  Tue May 26 00:53:21.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.027 2009  to  Tue May 26 00:53:21.027 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.028 2009  to  Tue May 26 00:53:21.028 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.029 2009  to  Tue May 26 00:53:21.029 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.029 2009  to  Tue May 26 00:53:21.029 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue May 26 00:58:47.594 2009  to  Tue May 26 00:58:47.594 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  13  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Tue May 26 01:03:04.277 2009  to  Tue May 26 01:03:04.277 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Tue May 26 01:10:46.633 2009  to  Tue May 26 01:10:46.633 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.782 2009  to  Tue May 26 01:13:13.782 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.782 2009  to  Tue May 26 01:13:13.782 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.783 2009  to  Tue May 26 01:13:13.783 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.783 2009  to  Tue May 26 01:13:13.783 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.785 2009  to  Tue May 26 01:13:13.785 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue May 26 01:18:24.171 2009  to  Tue May 26 01:18:24.171 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  24  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Tue May 26 01:18:30.440 2009  to  Tue May 26 01:18:30.440 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  25  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue May 26 01:18:38.793 2009  to  Tue May 26 01:18:38.793 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May 26 01:34:58.495 2009  to  Tue May 26 01:34:58.495 2009   (  0.00) secs
                     AZ bad poly no. 1: BAD Poly: velocity greater than 1.5 deg/sec

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 01:35:16.115 2009  to  Tue May 26 01:35:16.115 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 01:35:16.143 2009  to  Tue May 26 01:35:16.143 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Tue May 26 02:39:59.333 2009  to  Tue May 26 02:39:59.333 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 05:32:21.099 2009  to  Tue May 26 05:32:21.099 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 05:32:21.126 2009  to  Tue May 26 05:32:21.126 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.08   100.0 %         74         74                      
                                                                       0.00    0.05    0.05    0.08
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.07    0.15    0.11    0.45   100.0 %         98         98                      
                                                                       0.07    0.15    0.11    0.45
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.09    0.37    0.27    0.56   100.0 %         11         11                      
                                                                       0.09    0.37    0.27    0.56
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.07    0.05    0.14   100.0 %          8          8                      
                                                                       0.03    0.07    0.05    0.14
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.51    0.51    0.51   100.0 %          1          1                      
                                                                       0.00    0.51    0.51    0.51
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.22    0.45    0.29    0.82    77.8 %          9          7          2           
                                                                       0.24    0.49    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.05    0.00    0.11   100.0 %          4          4                      
                                                                       0.04    0.06    0.03    0.11

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Tue May 26 01:34:24.606 2009  to  Tue May 26 01:34:24.606 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

   2  FAILED    PCS        telescope.command.startTracking                               Tue May 26 01:34:58.418 2009  to  Tue May 26 01:34:58.726 2009   (  0.31) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly: velocity greater than 1.5 deg/sec

   3  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 26 01:35:15.029 2009  to  Tue May 26 01:35:15.096 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   4  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 26 01:35:15.178 2009  to  Tue May 26 01:35:15.178 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   5  FAILED    PCS        telescope.command.startTracking                               Tue May 26 05:05:58.140 2009  to  Tue May 26 05:05:58.435 2009   (  0.29) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.06    1.06    1.06   100.0 %          1          1                      
                                                                       0.00    1.06    1.06    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.77    2.86    2.06    5.06   100.0 %         39         39                      
                                                                       0.77    2.86    2.06    5.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    3.19    3.19    2.06   11.08   100.0 %          8          8                      
                                                                       3.19    3.19    2.06   11.08
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.06    5.06    5.06   100.0 %          1          1                      
                                                                       0.00    5.06    5.06    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.22   66.22   66.22   100.0 %          1          1                      
                                                                       0.00   66.22   66.22   66.22
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   12.38    7.28    2.06  122.38    98.8 %        252        249          3           
                                                                       8.64    6.49    2.06   78.25
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  447.42  447.42  447.42   100.0 %          1          1                      
                                                                       0.00  447.42  447.42  447.42
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.15    0.15    0.15   100.0 %          1          1                      
                                                                       0.00    0.15    0.15    0.15

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       8                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                            29
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                            28
     servoLoop.upperLimit.exceeded. . . . . . . . . . . . . . . . .                             8
     servoLoop.iUpperLimit.exceeded . . . . . . . . . . . . . . . .                             8
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             6
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             1
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             2
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           153
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       6                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             8
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      39                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       7                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon May 25 22:36:37.339 2009  to  Mon May 25 22:38:05.609 2009   ( 88.27) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.panic                                                  Mon May 25 22:38:05.227 2009  to  Mon May 25 22:38:05.227 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

   3  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:09:30.208 2009  to  Tue May 26 03:09:30.208 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

   4  FAILED    PMC        VxInterface.close                                             Tue May 26 03:09:30.262 2009  to  Tue May 26 03:09:30.262 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   5  FAILED    PMC        VxInterface.close                                             Tue May 26 03:12:33.532 2009  to  Tue May 26 03:12:33.532 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   6  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:12:33.480 2009  to  Tue May 26 03:12:33.480 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   7  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:22:58.900 2009  to  Tue May 26 03:22:58.900 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   8  FAILED    PMC        VxInterface.close                                             Tue May 26 03:22:58.953 2009  to  Tue May 26 03:22:58.953 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   9  FAILED    PMC        VxInterface.close                                             Tue May 26 03:35:31.624 2009  to  Tue May 26 03:35:31.624 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:35:31.571 2009  to  Tue May 26 03:35:31.571 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 26 03:56:24.474 2009  to  Tue May 26 03:58:26.852 2009   (122.38) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:06:57.884 2009  to  Tue May 26 04:06:57.884 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  13  FAILED    PMC        VxInterface.close                                             Tue May 26 04:06:57.936 2009  to  Tue May 26 04:06:57.936 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 26 04:21:56.852 2009  to  Tue May 26 04:22:03.934 2009   (  7.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:21:57.347 2009  to  Tue May 26 04:21:57.347 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  16  FAILED    PMC        VxInterface.close                                             Tue May 26 04:21:57.400 2009  to  Tue May 26 04:21:57.400 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:21:59.361 2009  to  Tue May 26 04:21:59.361 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Tue May 26 04:21:59.471 2009  to  Tue May 26 04:21:59.471 2009   (  0.00) secs
                     right PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    6.33    6.32    0.40   48.27   100.0 %        124        124                      
                                                                       6.33    6.32    0.40   48.27
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         12         12                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .   12.10    7.04    2.41  122.74    98.3 %        119        117          2           
                                                                       5.71    6.05    2.41   37.54
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    6.33    6.43    0.51   48.38   100.0 %        124        124                      
                                                                       6.33    6.43    0.51   48.38
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.33    6.26    0.18   48.02   100.0 %        127        127                      
                                                                       6.33    6.26    0.18   48.02
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   12.37    7.46    2.19  122.52    98.8 %        252        249          3           
                                                                       8.63    6.67    2.19   78.41
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    3.18    3.37    2.20   11.22   100.0 %          8          8                      
                                                                       3.18    3.37    2.20   11.22
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.07    0.11    0.07    0.42   100.0 %         50         50                      
                                                                       0.07    0.11    0.07    0.42
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   30.04   62.18   17.60   90.87    80.0 %          5          4          1           
                                                                      29.33   55.01   17.60   80.83
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    6.32   11.87    4.32   20.37   100.0 %          6          6                      
                                                                       6.32   11.87    4.32   20.37
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .   12.10    6.93    2.30  122.63    98.3 %        119        117          2           
                                                                       5.71    5.94    2.30   37.43
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          5          5                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.57    4.91    4.51    5.32   100.0 %          2          2                      
                                                                       0.57    4.91    4.51    5.32
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.05    0.11   100.0 %        129        129                      
                                                                       0.01    0.06    0.05    0.11

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                 32           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Mon May 25 22:36:34.873 2009  to  Mon May 25 22:38:05.746 2009   ( 90.87) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon May 25 22:36:37.277 2009  to  Mon May 25 22:38:05.687 2009   ( 88.41) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:50.019 2009  to  Tue May 26 01:51:50.019 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7976761e-04 -2.0346642e-03 3.1765699e-03 1.4689445e-02 5.3634644e-03 4.7343254e-02

   4  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:50.274 2009  to  Tue May 26 01:51:50.274 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7976761e-04 -2.0346642e-03 3.1765699e-03 1.4689445e-02 5.3634644e-03 4.7343254e-02

   5  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:52.750 2009  to  Tue May 26 01:51:52.750 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:53.004 2009  to  Tue May 26 01:51:53.004 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:38.585 2009  to  Tue May 26 01:52:38.585 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:38.841 2009  to  Tue May 26 01:52:38.841 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:57.971 2009  to  Tue May 26 01:52:57.971 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.226 2009  to  Tue May 26 01:52:58.226 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.481 2009  to  Tue May 26 01:52:58.481 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.4058094e-04 -1.7406940e-03 3.3574104e-03 2.1225929e-02 2.6996613e-02 3.7096977e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.736 2009  to  Tue May 26 01:52:58.736 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.4058094e-04 -1.7406940e-03 3.3574104e-03 2.1225929e-02 2.6996613e-02 3.7096977e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.092 2009  to  Tue May 26 01:53:06.092 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.347 2009  to  Tue May 26 01:53:06.347 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.601 2009  to  Tue May 26 01:53:06.601 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:09.117 2009  to  Tue May 26 01:53:09.117 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.2210350e-04 -1.1518002e-03 3.3520460e-03 1.1832237e-02 6.5589905e-02 3.7404060e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:09.372 2009  to  Tue May 26 01:53:09.372 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.2210350e-04 -1.1518002e-03 3.3520460e-03 1.1832237e-02 6.5589905e-02 3.7404060e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.450 2009  to  Tue May 26 02:48:43.450 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.705 2009  to  Tue May 26 02:48:43.705 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.960 2009  to  Tue May 26 02:48:43.960 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.407 2009  to  Tue May 26 02:53:35.407 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.661 2009  to  Tue May 26 02:53:35.661 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.915 2009  to  Tue May 26 02:53:35.915 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:54:16.887 2009  to  Tue May 26 02:54:16.887 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0159950e-05 2.0575523e-04 -9.6863508e-04 -1.5559959e-01 1.2780762e-01 8.5099220e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:54:17.143 2009  to  Tue May 26 02:54:17.143 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0159950e-05 2.0575523e-04 -9.6863508e-04 -1.5559959e-01 1.2780762e-01 8.5099220e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:55:53.548 2009  to  Tue May 26 02:55:53.548 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.7338009e-04 5.0520897e-04 1.2922287e-04 -8.1900597e-02 1.5353394e-01 4.3587685e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:55:53.803 2009  to  Tue May 26 02:55:53.803 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.7338009e-04 5.0520897e-04 1.2922287e-04 -8.1900597e-02 1.5353394e-01 4.3587685e-02

  28  FAILED    PSF        command.setInstrumentOffsets                                  Tue May 26 03:56:24.300 2009  to  Tue May 26 03:58:27.040 2009   (122.74) secs
                     right PSF SetInstrumentOffsets failed

  29  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue May 26 03:56:24.352 2009  to  Tue May 26 03:58:26.983 2009   (122.63) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 26 03:56:24.404 2009  to  Tue May 26 03:58:26.925 2009   (122.52) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  FAILED    PSF        command.setInstrumentOffsets                                  Tue May 26 04:21:56.683 2009  to  Tue May 26 04:22:04.120 2009   (  7.44) secs
                     right PSF SetInstrumentOffsets failed

  32  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue May 26 04:21:56.735 2009  to  Tue May 26 04:22:04.063 2009   (  7.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  33  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 26 04:21:56.787 2009  to  Tue May 26 04:22:04.007 2009   (  7.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PSF        primaryMirror.command.revert                                  Mon May 25 22:36:34.873 2009  to  Mon May 25 22:38:05.746 2009   ( 90.87) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon May 25 22:36:37.277 2009  to  Mon May 25 22:38:05.687 2009   ( 88.41) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon May 25 22:36:37.339 2009  to  Mon May 25 22:38:05.609 2009   ( 88.27) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PMC        mirror.panic                                                  Mon May 25 22:38:05.227 2009  to  Mon May 25 22:38:05.227 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 00:53:19.905 2009  to  Tue May 26 00:53:19.905 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 00:53:19.914 2009  to  Tue May 26 00:53:19.914 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue May 26 00:53:20.012 2009  to  Tue May 26 00:53:20.012 2009   (  0.00) secs
                     drive cabinet has turned on.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.025 2009  to  Tue May 26 00:53:21.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.026 2009  to  Tue May 26 00:53:21.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.027 2009  to  Tue May 26 00:53:21.027 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.028 2009  to  Tue May 26 00:53:21.028 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.029 2009  to  Tue May 26 00:53:21.029 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 00:53:21.029 2009  to  Tue May 26 00:53:21.029 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue May 26 00:58:47.594 2009  to  Tue May 26 00:58:47.594 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  17  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Tue May 26 01:03:04.277 2009  to  Tue May 26 01:03:04.277 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

  18  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Tue May 26 01:10:46.633 2009  to  Tue May 26 01:10:46.633 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.782 2009  to  Tue May 26 01:13:13.782 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.782 2009  to  Tue May 26 01:13:13.782 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.783 2009  to  Tue May 26 01:13:13.783 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.783 2009  to  Tue May 26 01:13:13.783 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.784 2009  to  Tue May 26 01:13:13.784 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 26 01:13:13.785 2009  to  Tue May 26 01:13:13.785 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue May 26 01:18:24.171 2009  to  Tue May 26 01:18:24.171 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  28  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Tue May 26 01:18:30.440 2009  to  Tue May 26 01:18:30.440 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  29  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue May 26 01:18:38.793 2009  to  Tue May 26 01:18:38.793 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  30  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 26 01:22:58.346 2009  to  Tue May 26 01:34:17.456 2009   (679.11) secs
                     IIF TCS authorize command failed for left LBC at prime focus

  31  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 26 01:22:58.361 2009  to  Tue May 26 01:34:17.402 2009   (679.04) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for left LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for right LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize alert for left LBC at prime focus: Invalid buffer: RPCERROR
                     IIF TCS authorize command failed for right LBC at prime focus

  32  SEQERROR  IIF        command.preset.(TRACK)                                        Tue May 26 01:31:34.159 2009  to  Tue May 26 01:33:14.947 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  33  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:31:36.210 2009  to  Tue May 26 01:32:17.684 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735575231481e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  34  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:32:17.684 2009  to  Tue May 26 01:33:17.002 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735643518518e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  35  FAILED    IIF        command.preset.(TRACK)                                        Tue May 26 01:33:14.947 2009  to  Tue May 26 01:34:17.249 2009   ( 62.30) secs
                     IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                     IIF Preset command failed for both LBC mode TRACK from IIF

  36  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:33:17.002 2009  to  Tue May 26 01:33:30.196 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.497735659722222e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  37  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.126 2009  to  Tue May 26 01:34:17.126 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735575231481e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  38  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.127 2009  to  Tue May 26 01:34:17.127 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735659722222e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  39  SEQERROR  IIF        command.getTrajectory                                         Tue May 26 01:34:17.128 2009  to  Tue May 26 01:34:17.128 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.497735643518518e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  40  SEQERROR  IIF        command.preset.(TRACK)                                        Tue May 26 01:34:17.251 2009  to  Tue May 26 01:34:17.251 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for both LBC mode TRACK from IIF

  41  STARTUP   PCS        startup                                                       Tue May 26 01:34:24.606 2009  to  Tue May 26 01:34:24.606 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

  42  FAILED    PCS        telescope.command.startTracking                               Tue May 26 01:34:58.418 2009  to  Tue May 26 01:34:58.726 2009   (  0.31) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly: velocity greater than 1.5 deg/sec

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May 26 01:34:58.495 2009  to  Tue May 26 01:34:58.495 2009   (  0.00) secs
                     AZ bad poly no. 1: BAD Poly: velocity greater than 1.5 deg/sec

  44  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 26 01:35:15.029 2009  to  Tue May 26 01:35:15.096 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  45  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 26 01:35:15.178 2009  to  Tue May 26 01:35:15.178 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 01:35:16.115 2009  to  Tue May 26 01:35:16.115 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 01:35:16.143 2009  to  Tue May 26 01:35:16.143 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  48  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:50.019 2009  to  Tue May 26 01:51:50.019 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7976761e-04 -2.0346642e-03 3.1765699e-03 1.4689445e-02 5.3634644e-03 4.7343254e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:50.274 2009  to  Tue May 26 01:51:50.274 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.7976761e-04 -2.0346642e-03 3.1765699e-03 1.4689445e-02 5.3634644e-03 4.7343254e-02

  50  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:52.750 2009  to  Tue May 26 01:51:52.750 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  51  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:51:53.004 2009  to  Tue May 26 01:51:53.004 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  52  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:38.585 2009  to  Tue May 26 01:52:38.585 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  53  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:38.841 2009  to  Tue May 26 01:52:38.841 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  54  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:57.971 2009  to  Tue May 26 01:52:57.971 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.226 2009  to  Tue May 26 01:52:58.226 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.5521049e-04 -2.0453930e-03 3.1648874e-03 3.7690163e-02 4.4536591e-02 2.6192665e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.481 2009  to  Tue May 26 01:52:58.481 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.4058094e-04 -1.7406940e-03 3.3574104e-03 2.1225929e-02 2.6996613e-02 3.7096977e-02

  57  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:52:58.736 2009  to  Tue May 26 01:52:58.736 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.4058094e-04 -1.7406940e-03 3.3574104e-03 2.1225929e-02 2.6996613e-02 3.7096977e-02

  58  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.092 2009  to  Tue May 26 01:53:06.092 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  59  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.347 2009  to  Tue May 26 01:53:06.347 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  60  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:06.601 2009  to  Tue May 26 01:53:06.601 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6117096e-04 -1.4457703e-03 3.1712055e-03 5.2995682e-03 4.3960571e-02 4.7646523e-02

  61  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:09.117 2009  to  Tue May 26 01:53:09.117 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.2210350e-04 -1.1518002e-03 3.3520460e-03 1.1832237e-02 6.5589905e-02 3.7404060e-02

  62  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 01:53:09.372 2009  to  Tue May 26 01:53:09.372 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.2210350e-04 -1.1518002e-03 3.3520460e-03 1.1832237e-02 6.5589905e-02 3.7404060e-02

  63  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Tue May 26 02:39:59.333 2009  to  Tue May 26 02:39:59.333 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  64  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.450 2009  to  Tue May 26 02:48:43.450 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  65  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.705 2009  to  Tue May 26 02:48:43.705 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  66  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:48:43.960 2009  to  Tue May 26 02:48:43.960 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.7974796e-04 8.7690353e-04 -1.2174249e-03 -1.1790180e-01 1.5083694e-01 7.1629524e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.407 2009  to  Tue May 26 02:53:35.407 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  68  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.661 2009  to  Tue May 26 02:53:35.661 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  69  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:53:35.915 2009  to  Tue May 26 02:53:35.915 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.1711330e-04 8.8000298e-04 -1.3883114e-03 -1.6310692e-01 1.1687088e-01 8.2436562e-02

  70  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:54:16.887 2009  to  Tue May 26 02:54:16.887 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0159950e-05 2.0575523e-04 -9.6863508e-04 -1.5559959e-01 1.2780762e-01 8.5099220e-02

  71  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:54:17.143 2009  to  Tue May 26 02:54:17.143 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0159950e-05 2.0575523e-04 -9.6863508e-04 -1.5559959e-01 1.2780762e-01 8.5099220e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:55:53.548 2009  to  Tue May 26 02:55:53.548 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.7338009e-04 5.0520897e-04 1.2922287e-04 -8.1900597e-02 1.5353394e-01 4.3587685e-02

  73  FAILED    PSF        primaryMirror.positionError                                   Tue May 26 02:55:53.803 2009  to  Tue May 26 02:55:53.803 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.7338009e-04 5.0520897e-04 1.2922287e-04 -8.1900597e-02 1.5353394e-01 4.3587685e-02

  74  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:09:30.208 2009  to  Tue May 26 03:09:30.208 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  75  FAILED    PMC        VxInterface.close                                             Tue May 26 03:09:30.262 2009  to  Tue May 26 03:09:30.262 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  76  FAILED    PMC        VxInterface.close                                             Tue May 26 03:12:33.532 2009  to  Tue May 26 03:12:33.532 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  77  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:12:33.480 2009  to  Tue May 26 03:12:33.480 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  78  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:22:58.900 2009  to  Tue May 26 03:22:58.900 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  79  FAILED    PMC        VxInterface.close                                             Tue May 26 03:22:58.953 2009  to  Tue May 26 03:22:58.953 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  80  FAILED    PMC        VxInterface.close                                             Tue May 26 03:35:31.624 2009  to  Tue May 26 03:35:31.624 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  81  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 03:35:31.571 2009  to  Tue May 26 03:35:31.571 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  82  FAILED    IIF        command.moveFocus                                             Tue May 26 03:56:24.234 2009  to  Tue May 26 03:58:27.209 2009   (122.98) secs
                     IIF GetTrajectory command started for both LBC, start time 5.497745584490741e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  83  FAILED    PSF        command.setInstrumentOffsets                                  Tue May 26 03:56:24.300 2009  to  Tue May 26 03:58:27.040 2009   (122.74) secs
                     right PSF SetInstrumentOffsets failed

  84  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue May 26 03:56:24.352 2009  to  Tue May 26 03:58:26.983 2009   (122.63) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  85  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 26 03:56:24.404 2009  to  Tue May 26 03:58:26.925 2009   (122.52) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  86  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 26 03:56:24.474 2009  to  Tue May 26 03:58:26.852 2009   (122.38) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:06:57.884 2009  to  Tue May 26 04:06:57.884 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  88  FAILED    PMC        VxInterface.close                                             Tue May 26 04:06:57.936 2009  to  Tue May 26 04:06:57.936 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  89  FAILED    IIF        command.moveFocus                                             Tue May 26 04:21:56.622 2009  to  Tue May 26 04:22:04.290 2009   (  7.67) secs
                     IIF MoveFocus command started for right LBC for 1.390000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01

  90  FAILED    PSF        command.setInstrumentOffsets                                  Tue May 26 04:21:56.683 2009  to  Tue May 26 04:22:04.120 2009   (  7.44) secs
                     right PSF SetInstrumentOffsets failed

  91  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue May 26 04:21:56.735 2009  to  Tue May 26 04:22:04.063 2009   (  7.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  92  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 26 04:21:56.787 2009  to  Tue May 26 04:22:04.007 2009   (  7.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  93  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 26 04:21:56.852 2009  to  Tue May 26 04:22:03.934 2009   (  7.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  94  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:21:57.347 2009  to  Tue May 26 04:21:57.347 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  95  FAILED    PMC        VxInterface.close                                             Tue May 26 04:21:57.400 2009  to  Tue May 26 04:21:57.400 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  96  FAILED    PMC        VxInterface.lengthError                                       Tue May 26 04:21:59.361 2009  to  Tue May 26 04:21:59.361 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  97  FAILED    PMC        VxInterface.close                                             Tue May 26 04:21:59.471 2009  to  Tue May 26 04:21:59.471 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  98  FAILED    PCS        telescope.command.startTracking                               Tue May 26 05:05:58.140 2009  to  Tue May 26 05:05:58.435 2009   (  0.29) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

  99  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 05:32:21.099 2009  to  Tue May 26 05:32:21.099 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 26 05:32:21.126 2009  to  Tue May 26 05:32:21.126 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

**********************************************************
    Reporting period ending:   Tue May 26 05:44:56.132 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback