You are here: Foswiki>Software Web>TCSSWReportFile_090523 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 23 2009 to May 24 2009
 
    Reporting period beginning:   Sat May 23 18:47:03.222 2009
    Reporting period ending:      Sun May 24 05:44:49.825 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.02    0.28    0.27    0.29   100.0 %          2          2                      
                                                                       0.02    0.28    0.27    0.29
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    9.99   84.87   77.81   91.93    50.0 %          2          1          1           
                                                                       0.00   77.81   77.81   77.81

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Sat May 23 19:48:27.772 2009  to  Sat May 23 19:49:59.703 2009   ( 91.93) secs
                     IIF GetTrajectory command started for both LBC, start time 5.497511699074074e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3272                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6544                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     126                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .       3                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            46
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      44                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      15                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            16
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      33                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  4           
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      10                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.Stowpins.stowpinMoving . . . . . . . . . . . . .                  6           
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      28                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             6
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  3           
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.AZDrive.hbsNotReady. . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .       7                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.044 2009  to  Sat May 23 20:45:00.044 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   2  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.045 2009  to  Sat May 23 20:45:00.045 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   3  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.045 2009  to  Sat May 23 20:45:00.045 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   4  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.046 2009  to  Sat May 23 20:45:00.046 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   5  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sat May 23 22:19:09.855 2009  to  Sat May 23 22:19:09.855 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   6  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sat May 23 22:19:09.860 2009  to  Sat May 23 22:19:09.860 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   7  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat May 23 23:23:16.275 2009  to  Sat May 23 23:23:16.275 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

   8  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat May 23 23:23:31.420 2009  to  Sat May 23 23:23:31.420 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

   9  FAILED    MCS.MCSPU  MCSPU.AZDrive.hbsNotReady                                     Sat May 23 23:23:33.211 2009  to  Sat May 23 23:23:33.211 2009   (  0.00) secs
                     Cannot leave IDLE state, because HBS is not ready or shows alarm.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May 24 01:00:13.549 2009  to  Sun May 24 01:00:13.549 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May 24 01:00:13.553 2009  to  Sun May 24 01:00:13.553 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  12  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Sun May 24 01:00:13.649 2009  to  Sun May 24 01:00:13.649 2009   (  0.00) secs
                     drive cabinet has turned on.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.669 2009  to  Sun May 24 01:00:14.669 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.670 2009  to  Sun May 24 01:00:14.670 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.670 2009  to  Sun May 24 01:00:14.670 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.671 2009  to  Sun May 24 01:00:14.671 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.672 2009  to  Sun May 24 01:00:14.672 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.673 2009  to  Sun May 24 01:00:14.673 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.673 2009  to  Sun May 24 01:00:14.673 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.674 2009  to  Sun May 24 01:00:14.674 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sun May 24 01:00:29.498 2009  to  Sun May 24 01:00:29.498 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  22  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sun May 24 01:08:33.647 2009  to  Sun May 24 01:08:33.647 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  23  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:13:27.674 2009  to  Sun May 24 01:13:27.674 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  24  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:13:27.675 2009  to  Sun May 24 01:13:27.675 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  25  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:21:25.425 2009  to  Sun May 24 01:21:25.425 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  26  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:21:25.427 2009  to  Sun May 24 01:21:25.427 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.13    0.11    0.14   100.0 %          2          2                      
                                                                       0.02    0.13    0.11    0.14
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.00    0.56    0.56    0.56   100.0 %          1          1                      
                                                                       0.00    0.56    0.56    0.56

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.53    0.61    0.05    1.06    55.6 %          9          5          4           
                                                                       0.00    1.06    1.06    1.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.07   100.0 %          7          7                      
                                                                       0.00    2.06    2.06    2.07
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    2.34    3.70    0.05    5.07    72.7 %         11          8          3           
                                                                       0.00    5.06    5.06    5.07
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .   24.15   28.44    0.05   66.22    27.3 %         22          6         16           
                                                                       0.01   66.21   66.20   66.22
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   39.82   56.60    0.05  125.37    70.0 %         10          7          3           
                                                                      28.37   49.89    2.06   77.25
     mirror.command.lower.auto. . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06     0.0 %          2                     2           
                                                                                                   
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    0.00   11.08   11.08   11.08    80.0 %          5          4          1           
                                                                       0.00   11.08   11.08   11.08
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .  583.02  326.31    0.17 1743.74    37.5 %          8          3          5           
                                                                      65.27  230.83  159.68  287.94
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.03    0.10    0.07    0.15   100.0 %          8          8                      
                                                                       0.03    0.10    0.07    0.15

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       7                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           226
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           224
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            91
     servoLoop.upperLimit.exceeded. . . . . . . . . . . . . . . . .                            70
     servoLoop.iUpperLimit.exceeded . . . . . . . . . . . . . . . .                            68
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  8           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       6                      
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                          1596
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             6
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             2
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             4
     actuator.setForce.addressError . . . . . . . . . . . . . . . .                  5           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                201           
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                  2           
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                            24
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                            17
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      44                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      44                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      44                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      44                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      44                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      44                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       6                      
     mirror.autoRaiseRaiseTimeOut . . . . . . . . . . . . . . . . .                  2           
     airPressure.noAir. . . . . . . . . . . . . . . . . . . . . . .                 14           
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       6                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     actuator.getForce.readError. . . . . . . . . . . . . . . . . .                  8           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.autoRaiseChaseTimeOut . . . . . . . . . . . . . . . . .                  1           
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       3                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 18:56:42.568 2009  to  Sat May 23 18:58:47.941 2009   (125.37) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.panic                                                  Sat May 23 19:00:27.191 2009  to  Sat May 23 19:00:27.191 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

   3  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.373 2009  to  Sat May 23 19:00:29.373 2009   (  0.00) secs
                     right PMC Actuator 219 has been reset

   4  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:29.321 2009  to  Sat May 23 19:00:29.321 2009   (  0.00) secs
                     right PMC Actuator 231 set force bad return: 179 instead of 7

   5  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.425 2009  to  Sat May 23 19:00:29.425 2009   (  0.00) secs
                     right PMC Actuator 227 has been reset

   6  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.529 2009  to  Sat May 23 19:00:29.529 2009   (  0.00) secs
                     right PMC Actuator 230 has been reset

   7  FAILED    PMC        actuator.setForce.readError                                   Sat May 23 19:00:29.477 2009  to  Sat May 23 19:00:29.477 2009   (  0.00) secs
                     right PMC Actuator 221 set force read error: -3

   8  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.836 2009  to  Sat May 23 19:00:29.836 2009   (  0.00) secs
                     right PMC Actuator 235 has been reset

   9  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.890 2009  to  Sat May 23 19:00:29.890 2009   (  0.00) secs
                     right PMC Actuator 307 has been reset

  10  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.944 2009  to  Sat May 23 19:00:29.944 2009   (  0.00) secs
                     right PMC Actuator 323 has been reset

  11  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.997 2009  to  Sat May 23 19:00:29.997 2009   (  0.00) secs
                     right PMC Actuator 325 has been reset

  12  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.053 2009  to  Sat May 23 19:00:30.053 2009   (  0.00) secs
                     right PMC Actuator 326 has been reset

  13  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.106 2009  to  Sat May 23 19:00:30.106 2009   (  0.00) secs
                     right PMC Actuator 333 has been reset

  14  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.160 2009  to  Sat May 23 19:00:30.160 2009   (  0.00) secs
                     right PMC Actuator 407 has been reset

  15  FAILED    PMC        actuator.setForce.readError                                   Sat May 23 19:00:30.212 2009  to  Sat May 23 19:00:30.212 2009   (  0.00) secs
                     right PMC Actuator 225 set force read error: -3

  16  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.325 2009  to  Sat May 23 19:00:30.325 2009   (  0.00) secs
                     right PMC Actuator 306 has been reset

  17  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:30.271 2009  to  Sat May 23 19:00:30.271 2009   (  0.00) secs
                     right PMC Actuator 232 set force bad return: 36 instead of 8

  18  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.383 2009  to  Sat May 23 19:00:30.383 2009   (  0.00) secs
                     right PMC Actuator 311 has been reset

  19  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.436 2009  to  Sat May 23 19:00:30.436 2009   (  0.00) secs
                     right PMC Actuator 304 has been reset

  20  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.490 2009  to  Sat May 23 19:00:30.490 2009   (  0.00) secs
                     right PMC Actuator 310 has been reset

  21  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.546 2009  to  Sat May 23 19:00:30.546 2009   (  0.00) secs
                     right PMC Actuator 312 has been reset

  22  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.600 2009  to  Sat May 23 19:00:30.600 2009   (  0.00) secs
                     right PMC Actuator 316 has been reset

  23  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.655 2009  to  Sat May 23 19:00:30.655 2009   (  0.00) secs
                     right PMC Actuator 315 has been reset

  24  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.707 2009  to  Sat May 23 19:00:30.707 2009   (  0.00) secs
                     right PMC Actuator 308 has been reset

  25  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.760 2009  to  Sat May 23 19:00:30.760 2009   (  0.00) secs
                     right PMC Actuator 309 has been reset

  26  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.813 2009  to  Sat May 23 19:00:30.813 2009   (  0.00) secs
                     right PMC Actuator 314 has been reset

  27  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.865 2009  to  Sat May 23 19:00:30.865 2009   (  0.00) secs
                     right PMC Actuator 321 has been reset

  28  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.917 2009  to  Sat May 23 19:00:30.917 2009   (  0.00) secs
                     right PMC Actuator 322 has been reset

  29  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.969 2009  to  Sat May 23 19:00:30.969 2009   (  0.00) secs
                     right PMC Actuator 328 has been reset

  30  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:31.025 2009  to  Sat May 23 19:00:31.025 2009   (  0.00) secs
                     right PMC Actuator 319 has been reset

  31  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:31.077 2009  to  Sat May 23 19:00:31.077 2009   (  0.00) secs
                     right PMC Actuator 313 has been reset

  32  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:32.518 2009  to  Sat May 23 19:00:32.518 2009   (  0.00) secs
                     right PMC Actuator 226 set force bad return: 254 instead of 9

  33  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:11:10.826 2009  to  Sat May 23 19:13:37.377 2009   (146.55) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  34  FAILED    PMC        mirror.command.lower.auto                                     Sat May 23 19:13:33.136 2009  to  Sat May 23 19:13:33.199 2009   (  0.06) secs
                     right PMC Mirror AutoLower Command Started
                     right PMC Mirror AutoLower Command Failed because Wrong mirror state

  35  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Sat May 23 19:13:36.856 2009  to  Sat May 23 19:13:36.856 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

  36  FAILED    PMC        mirror.panic                                                  Sat May 23 19:13:36.912 2009  to  Sat May 23 19:13:36.912 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  37  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:17:27.412 2009  to  Sat May 23 19:17:27.584 2009   (  0.17) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 9.0000000e+01
                     right PMC Mirror AutoRaise Command Failed because Air not on

  38  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:27:42.181 2009  to  Sat May 23 19:27:56.260 2009   ( 14.08) secs
                     right PMC No AIR pressure on BLUE loop: 62.8 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  39  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:27:55.372 2009  to  Sat May 23 19:27:55.372 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 62.8 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  40  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:28:40.798 2009  to  Sat May 23 19:28:56.887 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 48.5 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  41  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:28:56.468 2009  to  Sat May 23 19:28:56.468 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 48.5 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  42  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 19:28:59.901 2009  to  Sat May 23 19:28:59.959 2009   (  0.06) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  43  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 19:29:04.000 2009  to  Sat May 23 19:29:04.053 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  44  FAILED    PMC        mirror.command.panic                                          Sat May 23 19:29:11.292 2009  to  Sat May 23 19:29:22.369 2009   ( 11.08) secs
                     right PMC RecoverPanic Command Started
                     right PMC Mirror Panic Command Failed because PANIC failed to complete

  45  FAILED    PMC        mirror.panic                                                  Sat May 23 19:29:11.433 2009  to  Sat May 23 19:29:11.433 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  46  FAILED    PMC        command.recoverPanic                                          Sat May 23 19:29:40.513 2009  to  Sat May 23 19:29:40.573 2009   (  0.06) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong cell state

  47  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:29:46.300 2009  to  Sat May 23 19:30:02.388 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  48  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:30:02.356 2009  to  Sat May 23 19:30:02.356 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  49  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:30:45.850 2009  to  Sat May 23 19:31:01.942 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 19:30:49.709 2009  to  Sat May 23 19:30:49.763 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  51  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:31:01.791 2009  to  Sat May 23 19:31:01.791 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  52  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:31:10.482 2009  to  Sat May 23 19:31:10.543 2009   (  0.06) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 1
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: OFF because Wrong air state

  53  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:31:12.805 2009  to  Sat May 23 19:31:28.896 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.2 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  54  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:31:28.809 2009  to  Sat May 23 19:31:28.809 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.2 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  55  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:32:10.688 2009  to  Sat May 23 19:32:26.781 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  56  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:32:26.392 2009  to  Sat May 23 19:32:26.392 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 19:48:28.020 2009  to  Sat May 23 19:49:59.293 2009   ( 91.27) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PMC        mirror.panic                                                  Sat May 23 19:50:00.048 2009  to  Sat May 23 19:50:00.048 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  59  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:01.473 2009  to  Sat May 23 19:50:01.473 2009   (  0.00) secs
                     right PMC Actuator 305 get force read error: -3

  60  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:02.290 2009  to  Sat May 23 19:50:02.290 2009   (  0.00) secs
                     right PMC Actuator 314 get force read error: -3

  61  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:03.105 2009  to  Sat May 23 19:50:03.105 2009   (  0.00) secs
                     right PMC Actuator 330 get force read error: -3

  62  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:04.426 2009  to  Sat May 23 19:50:04.426 2009   (  0.00) secs
                     right PMC Actuator 323 get force read error: -3

  63  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:05.235 2009  to  Sat May 23 19:50:05.235 2009   (  0.00) secs
                     right PMC Actuator 333 get force read error: -3

  64  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:06.046 2009  to  Sat May 23 19:50:06.046 2009   (  0.00) secs
                     right PMC Actuator 333 get force read error: -3

  65  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:07.113 2009  to  Sat May 23 19:50:07.113 2009   (  0.00) secs
                     right PMC Actuator 103 get force read error: -3

  66  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:08.177 2009  to  Sat May 23 19:50:08.177 2009   (  0.00) secs
                     right PMC Actuator 212 get force read error: -3

  67  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:50:09.347 2009  to  Sat May 23 19:50:09.347 2009   (  0.00) secs
                     right PMC Actuator 101 set force bad return: 43 instead of 1

  68  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:50:10.857 2009  to  Sat May 23 19:50:10.857 2009   (  0.00) secs
                     right PMC Actuator 116 set force bad return: 225 instead of 2

  69  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:58:16.614 2009  to  Sat May 23 19:58:16.824 2009   (  0.21) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 8.9998947e+01
                     right PMC Mirror AutoRaise Command Failed because Air not on

  70  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:59:45.208 2009  to  Sat May 23 20:00:12.520 2009   ( 27.31) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  71  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Sat May 23 20:00:12.362 2009  to  Sat May 23 20:00:12.362 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

  72  FAILED    PMC        mirror.panic                                                  Sat May 23 20:00:12.415 2009  to  Sat May 23 20:00:12.415 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  73  FAILED    PMC        mirror.panic                                                  Sat May 23 23:27:57.672 2009  to  Sat May 23 23:27:57.672 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  74  FAILED    PMC        mirror.panic                                                  Sat May 23 23:50:10.743 2009  to  Sat May 23 23:50:10.743 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  75  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 23:50:13.712 2009  to  Sat May 23 23:50:13.758 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  76  FAILED    PMC        command.recoverPanic                                          Sat May 23 23:50:16.266 2009  to  Sat May 23 23:50:16.320 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

  77  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:51:39.886 2009  to  Sat May 23 23:51:55.970 2009   ( 16.08) secs
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  78  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:51:56.036 2009  to  Sat May 23 23:51:56.036 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0

  79  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:55:02.649 2009  to  Sat May 23 23:55:18.745 2009   ( 16.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  80  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:55:18.677 2009  to  Sat May 23 23:55:18.677 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  81  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:55:29.172 2009  to  Sat May 23 23:55:46.268 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  82  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:55:45.483 2009  to  Sat May 23 23:55:45.483 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  83  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:11.666 2009  to  Sat May 23 23:56:28.765 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  84  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:56:27.969 2009  to  Sat May 23 23:56:27.969 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  85  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:31.559 2009  to  Sat May 23 23:56:47.645 2009   ( 16.09) secs
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  86  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:56:47.728 2009  to  Sat May 23 23:56:47.728 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0

  87  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:56.423 2009  to  Sat May 23 23:57:13.522 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  88  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:57:12.575 2009  to  Sat May 23 23:57:12.575 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  89  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:57:17.268 2009  to  Sat May 23 23:57:34.353 2009   ( 17.08) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  90  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:57:33.403 2009  to  Sat May 23 23:57:33.403 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  91  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:57:47.045 2009  to  Sat May 23 23:58:04.128 2009   ( 17.08) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  92  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:58:03.242 2009  to  Sat May 23 23:58:03.242 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  93  FAILED    PMC        command.recoverPanic                                          Sat May 23 23:58:25.553 2009  to  Sat May 23 23:58:25.606 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong cell state

  94  FAILED    PMC        mirror.command.raise.auto                                     Sun May 24 00:39:10.631 2009  to  Sun May 24 01:08:14.372 2009   (1743.74) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  95  FAILED    PMC        actuator.command.activate.all                                 Sun May 24 00:39:15.069 2009  to  Sun May 24 00:39:15.123 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong mirror state

  96  FAILED    PMC        mirror.autoRaiseChaseTimeOut                                  Sun May 24 00:55:13.946 2009  to  Sun May 24 00:55:13.946 2009   (  0.00) secs
                     right PMC Auto-raise time-out: chase failed to finish in alloted time

  97  FAILED    PMC        command.turnAllAirLoops                                       Sun May 24 01:08:03.023 2009  to  Sun May 24 01:08:03.078 2009   (  0.05) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 1
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: OFF because Wrong mirror state

  98  FAILED    PMC        mirror.command.lower.auto                                     Sun May 24 01:08:06.043 2009  to  Sun May 24 01:08:06.096 2009   (  0.05) secs
                     right PMC Mirror AutoLower Command Started
                     right PMC Mirror AutoLower Command Failed because Chase state not IDLE

  99  FAILED    PMC        mirror.panic                                                  Sun May 24 01:08:14.259 2009  to  Sun May 24 01:08:14.259 2009   (  0.00) secs
                     right PMC ** PANIC: User Button
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    9.92   84.63   77.62   91.65    50.0 %          2          1          1           
                                                                       0.00   77.62   77.62   77.62
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   39.80   56.77    0.38  125.51    70.0 %         10          7          3           
                                                                      28.40   50.06    2.20   77.41
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.20    2.20    2.20   100.0 %          1          1                      
                                                                       0.00    2.20    2.20    2.20
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.44    2.39    2.20    3.38   100.0 %          7          7                      
                                                                       0.44    2.39    2.20    3.38
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   40.17   59.56    4.56  129.56    85.7 %          7          6          1           
                                                                      28.16   47.89    4.56   79.77
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    9.92   84.52   77.51   91.54    50.0 %          2          1          1           
                                                                       0.00   77.51   77.51   77.51
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    0.48    0.48    0.48     0.0 %          1                     1           
                                                                                                   

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Sat May 23 18:56:38.514 2009  to  Sat May 23 18:58:48.071 2009   (129.56) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 18:56:42.506 2009  to  Sat May 23 18:58:48.014 2009   (125.51) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 19:30:49.639 2009  to  Sat May 23 19:30:50.015 2009   (  0.38) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   4  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sat May 23 19:30:49.586 2009  to  Sat May 23 19:30:50.071 2009   (  0.48) secs
                     right PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

   5  FAILED    PSF        command.setInstrumentOffsets                                  Sat May 23 19:48:27.839 2009  to  Sat May 23 19:49:59.484 2009   ( 91.65) secs
                     right PSF SetInstrumentOffsets failed

   6  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat May 23 19:48:27.891 2009  to  Sat May 23 19:49:59.428 2009   ( 91.54) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 19:48:27.943 2009  to  Sat May 23 19:49:59.371 2009   ( 91.43) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PSF        primaryMirror.command.revert                                  Sat May 23 18:56:38.514 2009  to  Sat May 23 18:58:48.071 2009   (129.56) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 18:56:42.568 2009  to  Sat May 23 18:58:47.941 2009   (125.37) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 18:56:42.506 2009  to  Sat May 23 18:58:48.014 2009   (125.51) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   4  FAILED    PMC        mirror.panic                                                  Sat May 23 19:00:27.191 2009  to  Sat May 23 19:00:27.191 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

   5  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.373 2009  to  Sat May 23 19:00:29.373 2009   (  0.00) secs
                     right PMC Actuator 219 has been reset

   6  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:29.321 2009  to  Sat May 23 19:00:29.321 2009   (  0.00) secs
                     right PMC Actuator 231 set force bad return: 179 instead of 7

   7  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.425 2009  to  Sat May 23 19:00:29.425 2009   (  0.00) secs
                     right PMC Actuator 227 has been reset

   8  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.529 2009  to  Sat May 23 19:00:29.529 2009   (  0.00) secs
                     right PMC Actuator 230 has been reset

   9  FAILED    PMC        actuator.setForce.readError                                   Sat May 23 19:00:29.477 2009  to  Sat May 23 19:00:29.477 2009   (  0.00) secs
                     right PMC Actuator 221 set force read error: -3

  10  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.836 2009  to  Sat May 23 19:00:29.836 2009   (  0.00) secs
                     right PMC Actuator 235 has been reset

  11  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.890 2009  to  Sat May 23 19:00:29.890 2009   (  0.00) secs
                     right PMC Actuator 307 has been reset

  12  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.944 2009  to  Sat May 23 19:00:29.944 2009   (  0.00) secs
                     right PMC Actuator 323 has been reset

  13  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:29.997 2009  to  Sat May 23 19:00:29.997 2009   (  0.00) secs
                     right PMC Actuator 325 has been reset

  14  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.053 2009  to  Sat May 23 19:00:30.053 2009   (  0.00) secs
                     right PMC Actuator 326 has been reset

  15  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.106 2009  to  Sat May 23 19:00:30.106 2009   (  0.00) secs
                     right PMC Actuator 333 has been reset

  16  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.160 2009  to  Sat May 23 19:00:30.160 2009   (  0.00) secs
                     right PMC Actuator 407 has been reset

  17  FAILED    PMC        actuator.setForce.readError                                   Sat May 23 19:00:30.212 2009  to  Sat May 23 19:00:30.212 2009   (  0.00) secs
                     right PMC Actuator 225 set force read error: -3

  18  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.325 2009  to  Sat May 23 19:00:30.325 2009   (  0.00) secs
                     right PMC Actuator 306 has been reset

  19  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:30.271 2009  to  Sat May 23 19:00:30.271 2009   (  0.00) secs
                     right PMC Actuator 232 set force bad return: 36 instead of 8

  20  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.383 2009  to  Sat May 23 19:00:30.383 2009   (  0.00) secs
                     right PMC Actuator 311 has been reset

  21  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.436 2009  to  Sat May 23 19:00:30.436 2009   (  0.00) secs
                     right PMC Actuator 304 has been reset

  22  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.490 2009  to  Sat May 23 19:00:30.490 2009   (  0.00) secs
                     right PMC Actuator 310 has been reset

  23  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.546 2009  to  Sat May 23 19:00:30.546 2009   (  0.00) secs
                     right PMC Actuator 312 has been reset

  24  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.600 2009  to  Sat May 23 19:00:30.600 2009   (  0.00) secs
                     right PMC Actuator 316 has been reset

  25  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.655 2009  to  Sat May 23 19:00:30.655 2009   (  0.00) secs
                     right PMC Actuator 315 has been reset

  26  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.707 2009  to  Sat May 23 19:00:30.707 2009   (  0.00) secs
                     right PMC Actuator 308 has been reset

  27  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.760 2009  to  Sat May 23 19:00:30.760 2009   (  0.00) secs
                     right PMC Actuator 309 has been reset

  28  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.813 2009  to  Sat May 23 19:00:30.813 2009   (  0.00) secs
                     right PMC Actuator 314 has been reset

  29  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.865 2009  to  Sat May 23 19:00:30.865 2009   (  0.00) secs
                     right PMC Actuator 321 has been reset

  30  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.917 2009  to  Sat May 23 19:00:30.917 2009   (  0.00) secs
                     right PMC Actuator 322 has been reset

  31  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:30.969 2009  to  Sat May 23 19:00:30.969 2009   (  0.00) secs
                     right PMC Actuator 328 has been reset

  32  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:31.025 2009  to  Sat May 23 19:00:31.025 2009   (  0.00) secs
                     right PMC Actuator 319 has been reset

  33  FAILED    PMC        actuator.reset                                                Sat May 23 19:00:31.077 2009  to  Sat May 23 19:00:31.077 2009   (  0.00) secs
                     right PMC Actuator 313 has been reset

  34  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:00:32.518 2009  to  Sat May 23 19:00:32.518 2009   (  0.00) secs
                     right PMC Actuator 226 set force bad return: 254 instead of 9

  35  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:11:10.826 2009  to  Sat May 23 19:13:37.377 2009   (146.55) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  36  FAILED    PMC        mirror.command.lower.auto                                     Sat May 23 19:13:33.136 2009  to  Sat May 23 19:13:33.199 2009   (  0.06) secs
                     right PMC Mirror AutoLower Command Started
                     right PMC Mirror AutoLower Command Failed because Wrong mirror state

  37  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Sat May 23 19:13:36.856 2009  to  Sat May 23 19:13:36.856 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

  38  FAILED    PMC        mirror.panic                                                  Sat May 23 19:13:36.912 2009  to  Sat May 23 19:13:36.912 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  39  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:17:27.412 2009  to  Sat May 23 19:17:27.584 2009   (  0.17) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 9.0000000e+01
                     right PMC Mirror AutoRaise Command Failed because Air not on

  40  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:27:42.181 2009  to  Sat May 23 19:27:56.260 2009   ( 14.08) secs
                     right PMC No AIR pressure on BLUE loop: 62.8 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  41  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:27:55.372 2009  to  Sat May 23 19:27:55.372 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 62.8 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  42  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:28:40.798 2009  to  Sat May 23 19:28:56.887 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 48.5 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  43  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:28:56.468 2009  to  Sat May 23 19:28:56.468 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 48.5 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  44  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 19:28:59.901 2009  to  Sat May 23 19:28:59.959 2009   (  0.06) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  45  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 19:29:04.000 2009  to  Sat May 23 19:29:04.053 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  46  FAILED    PMC        mirror.command.panic                                          Sat May 23 19:29:11.292 2009  to  Sat May 23 19:29:22.369 2009   ( 11.08) secs
                     right PMC RecoverPanic Command Started
                     right PMC Mirror Panic Command Failed because PANIC failed to complete

  47  FAILED    PMC        mirror.panic                                                  Sat May 23 19:29:11.433 2009  to  Sat May 23 19:29:11.433 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  48  FAILED    PMC        command.recoverPanic                                          Sat May 23 19:29:40.513 2009  to  Sat May 23 19:29:40.573 2009   (  0.06) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong cell state

  49  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:29:46.300 2009  to  Sat May 23 19:30:02.388 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  50  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:30:02.356 2009  to  Sat May 23 19:30:02.356 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  51  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:30:45.850 2009  to  Sat May 23 19:31:01.942 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 19:30:49.639 2009  to  Sat May 23 19:30:50.015 2009   (  0.38) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  53  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sat May 23 19:30:49.586 2009  to  Sat May 23 19:30:50.071 2009   (  0.48) secs
                     right PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  54  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 19:30:49.709 2009  to  Sat May 23 19:30:49.763 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  55  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:31:01.791 2009  to  Sat May 23 19:31:01.791 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  56  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:31:10.482 2009  to  Sat May 23 19:31:10.543 2009   (  0.06) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 1
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: OFF because Wrong air state

  57  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:31:12.805 2009  to  Sat May 23 19:31:28.896 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.2 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  58  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:31:28.809 2009  to  Sat May 23 19:31:28.809 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.2 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  59  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 19:32:10.688 2009  to  Sat May 23 19:32:26.781 2009   ( 16.09) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  60  FAILED    PMC        airPressure.noAir                                             Sat May 23 19:32:26.392 2009  to  Sat May 23 19:32:26.392 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  61  FAILED    IIF        command.moveFocus                                             Sat May 23 19:48:27.772 2009  to  Sat May 23 19:49:59.703 2009   ( 91.93) secs
                     IIF GetTrajectory command started for both LBC, start time 5.497511699074074e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  62  FAILED    PSF        command.setInstrumentOffsets                                  Sat May 23 19:48:27.839 2009  to  Sat May 23 19:49:59.484 2009   ( 91.65) secs
                     right PSF SetInstrumentOffsets failed

  63  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat May 23 19:48:27.891 2009  to  Sat May 23 19:49:59.428 2009   ( 91.54) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May 23 19:48:27.943 2009  to  Sat May 23 19:49:59.371 2009   ( 91.43) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  65  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May 23 19:48:28.020 2009  to  Sat May 23 19:49:59.293 2009   ( 91.27) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PMC        mirror.panic                                                  Sat May 23 19:50:00.048 2009  to  Sat May 23 19:50:00.048 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  67  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:01.473 2009  to  Sat May 23 19:50:01.473 2009   (  0.00) secs
                     right PMC Actuator 305 get force read error: -3

  68  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:02.290 2009  to  Sat May 23 19:50:02.290 2009   (  0.00) secs
                     right PMC Actuator 314 get force read error: -3

  69  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:03.105 2009  to  Sat May 23 19:50:03.105 2009   (  0.00) secs
                     right PMC Actuator 330 get force read error: -3

  70  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:04.426 2009  to  Sat May 23 19:50:04.426 2009   (  0.00) secs
                     right PMC Actuator 323 get force read error: -3

  71  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:05.235 2009  to  Sat May 23 19:50:05.235 2009   (  0.00) secs
                     right PMC Actuator 333 get force read error: -3

  72  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:06.046 2009  to  Sat May 23 19:50:06.046 2009   (  0.00) secs
                     right PMC Actuator 333 get force read error: -3

  73  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:07.113 2009  to  Sat May 23 19:50:07.113 2009   (  0.00) secs
                     right PMC Actuator 103 get force read error: -3

  74  FAILED    PMC        actuator.getForce.readError                                   Sat May 23 19:50:08.177 2009  to  Sat May 23 19:50:08.177 2009   (  0.00) secs
                     right PMC Actuator 212 get force read error: -3

  75  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:50:09.347 2009  to  Sat May 23 19:50:09.347 2009   (  0.00) secs
                     right PMC Actuator 101 set force bad return: 43 instead of 1

  76  FAILED    PMC        actuator.setForce.addressError                                Sat May 23 19:50:10.857 2009  to  Sat May 23 19:50:10.857 2009   (  0.00) secs
                     right PMC Actuator 116 set force bad return: 225 instead of 2

  77  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:58:16.614 2009  to  Sat May 23 19:58:16.824 2009   (  0.21) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 8.9998947e+01
                     right PMC Mirror AutoRaise Command Failed because Air not on

  78  FAILED    PMC        mirror.command.raise.auto                                     Sat May 23 19:59:45.208 2009  to  Sat May 23 20:00:12.520 2009   ( 27.31) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  79  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Sat May 23 20:00:12.362 2009  to  Sat May 23 20:00:12.362 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

  80  FAILED    PMC        mirror.panic                                                  Sat May 23 20:00:12.415 2009  to  Sat May 23 20:00:12.415 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  81  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.044 2009  to  Sat May 23 20:45:00.044 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  82  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.045 2009  to  Sat May 23 20:45:00.045 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  83  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.045 2009  to  Sat May 23 20:45:00.045 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  84  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat May 23 20:45:00.046 2009  to  Sat May 23 20:45:00.046 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  85  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sat May 23 22:19:09.855 2009  to  Sat May 23 22:19:09.855 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  86  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sat May 23 22:19:09.860 2009  to  Sat May 23 22:19:09.860 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

  87  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat May 23 23:23:16.275 2009  to  Sat May 23 23:23:16.275 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  88  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat May 23 23:23:31.420 2009  to  Sat May 23 23:23:31.420 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  89  FAILED    MCS.MCSPU  MCSPU.AZDrive.hbsNotReady                                     Sat May 23 23:23:33.211 2009  to  Sat May 23 23:23:33.211 2009   (  0.00) secs
                     Cannot leave IDLE state, because HBS is not ready or shows alarm.

  90  FAILED    PMC        mirror.panic                                                  Sat May 23 23:27:57.672 2009  to  Sat May 23 23:27:57.672 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  91  FAILED    PMC        mirror.panic                                                  Sat May 23 23:50:10.743 2009  to  Sat May 23 23:50:10.743 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  92  FAILED    PMC        actuator.command.activate.all                                 Sat May 23 23:50:13.712 2009  to  Sat May 23 23:50:13.758 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  93  FAILED    PMC        command.recoverPanic                                          Sat May 23 23:50:16.266 2009  to  Sat May 23 23:50:16.320 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

  94  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:51:39.886 2009  to  Sat May 23 23:51:55.970 2009   ( 16.08) secs
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  95  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:51:56.036 2009  to  Sat May 23 23:51:56.036 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0

  96  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:55:02.649 2009  to  Sat May 23 23:55:18.745 2009   ( 16.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  97  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:55:18.677 2009  to  Sat May 23 23:55:18.677 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  98  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:55:29.172 2009  to  Sat May 23 23:55:46.268 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

  99  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:55:45.483 2009  to  Sat May 23 23:55:45.483 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 100  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:11.666 2009  to  Sat May 23 23:56:28.765 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 101  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:56:27.969 2009  to  Sat May 23 23:56:27.969 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 102  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:31.559 2009  to  Sat May 23 23:56:47.645 2009   ( 16.09) secs
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 103  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:56:47.728 2009  to  Sat May 23 23:56:47.728 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0

 104  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:56:56.423 2009  to  Sat May 23 23:57:13.522 2009   ( 17.10) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 105  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:57:12.575 2009  to  Sat May 23 23:57:12.575 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 106  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:57:17.268 2009  to  Sat May 23 23:57:34.353 2009   ( 17.08) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 107  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:57:33.403 2009  to  Sat May 23 23:57:33.403 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 108  FAILED    PMC        command.turnAllAirLoops                                       Sat May 23 23:57:47.045 2009  to  Sat May 23 23:58:04.128 2009   ( 17.08) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 109  FAILED    PMC        airPressure.noAir                                             Sat May 23 23:58:03.242 2009  to  Sat May 23 23:58:03.242 2009   (  0.00) secs
                     right PMC No AIR pressure on BLUE loop: 1.6 psi, minimum is 90.0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because All air on failed to complete

 110  FAILED    PMC        command.recoverPanic                                          Sat May 23 23:58:25.553 2009  to  Sat May 23 23:58:25.606 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong cell state

 111  FAILED    PMC        mirror.command.raise.auto                                     Sun May 24 00:39:10.631 2009  to  Sun May 24 01:08:14.372 2009   (1743.74) secs
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 112  FAILED    PMC        actuator.command.activate.all                                 Sun May 24 00:39:15.069 2009  to  Sun May 24 00:39:15.123 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong mirror state

 113  FAILED    PMC        mirror.autoRaiseChaseTimeOut                                  Sun May 24 00:55:13.946 2009  to  Sun May 24 00:55:13.946 2009   (  0.00) secs
                     right PMC Auto-raise time-out: chase failed to finish in alloted time

 114  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May 24 01:00:13.549 2009  to  Sun May 24 01:00:13.549 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 115  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May 24 01:00:13.553 2009  to  Sun May 24 01:00:13.553 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 116  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Sun May 24 01:00:13.649 2009  to  Sun May 24 01:00:13.649 2009   (  0.00) secs
                     drive cabinet has turned on.

 117  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.669 2009  to  Sun May 24 01:00:14.669 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 118  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.670 2009  to  Sun May 24 01:00:14.670 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 119  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.670 2009  to  Sun May 24 01:00:14.670 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 120  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.671 2009  to  Sun May 24 01:00:14.671 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 121  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.672 2009  to  Sun May 24 01:00:14.672 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 122  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.673 2009  to  Sun May 24 01:00:14.673 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 123  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.673 2009  to  Sun May 24 01:00:14.673 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 124  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May 24 01:00:14.674 2009  to  Sun May 24 01:00:14.674 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 125  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sun May 24 01:00:29.498 2009  to  Sun May 24 01:00:29.498 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 126  FAILED    PMC        command.turnAllAirLoops                                       Sun May 24 01:08:03.023 2009  to  Sun May 24 01:08:03.078 2009   (  0.05) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 1
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: OFF because Wrong mirror state

 127  FAILED    PMC        mirror.command.lower.auto                                     Sun May 24 01:08:06.043 2009  to  Sun May 24 01:08:06.096 2009   (  0.05) secs
                     right PMC Mirror AutoLower Command Started
                     right PMC Mirror AutoLower Command Failed because Chase state not IDLE

 128  FAILED    PMC        mirror.panic                                                  Sun May 24 01:08:14.259 2009  to  Sun May 24 01:08:14.259 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

 129  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sun May 24 01:08:33.647 2009  to  Sun May 24 01:08:33.647 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 130  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:13:27.674 2009  to  Sun May 24 01:13:27.674 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

 131  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:13:27.675 2009  to  Sun May 24 01:13:27.675 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

 132  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:21:25.425 2009  to  Sun May 24 01:21:25.425 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

 133  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Sun May 24 01:21:25.427 2009  to  Sun May 24 01:21:25.427 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

**********************************************************
    Reporting period ending:   Sun May 24 05:44:49.825 2009
********************************************************************************************************