********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 20 2009 to May 21 2009
 
    Reporting period beginning:   Wed May 20 21:22:07.040 2009
    Reporting period ending:      Thu May 21 00:33:57.203 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   12.31    8.20    0.05   24.62    83.3 %          6          5          1           
                                                                      10.42    4.92    0.05   23.56

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Thu May 21 03:06:07.986 2009  to  Thu May 21 03:06:32.610 2009   ( 24.62) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05     0.0 %          2                     2           
                                                                                                   
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .    0.00  116.21  116.21  116.21     0.0 %          1                     1           
                                                                                                   
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    0.00   20.07   20.07   20.07   100.0 %          1          1                      
                                                                       0.00   20.07   20.07   20.07
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.authorize                                             Wed May 20 21:32:15.289 2009  to  Wed May 20 21:32:15.341 2009   (  0.05) secs
                     IIF Authorize command started for left MAT at prime focus (IIF left side)
                     IIF Authorize command failed for left MAT at prime focus (IIF left side)

   2  STARTUP   IIF        startup                                                       Thu May 21 00:47:22.083 2009  to  Thu May 21 00:47:22.083 2009   (  0.00) secs
                     IIF subsystem started

   3  FAILED    IIF        command.preset.(GUIDE)                                        Thu May 21 05:33:18.346 2009  to  Thu May 21 05:35:14.555 2009   (116.21) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   4  FAILED    IIF        command.authorize                                             Thu May 21 05:44:36.075 2009  to  Thu May 21 05:44:36.127 2009   (  0.05) secs
                     IIF Authorize command started for left MAT at prime focus (IIF left side)
                     IIF Authorize command failed for left MAT at prime focus (IIF left side)
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  1487                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  2943                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 16           
     weatherStation.noWeatherData . . . . . . . . . . . . . . . . .                  1           
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .       4                      

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:18.493 2009  to  Thu May 21 00:46:18.493 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:28.678 2009  to  Thu May 21 00:46:28.678 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   3  FAILED    ECS        weatherStation.noWeatherData                                  Thu May 21 00:46:29.011 2009  to  Thu May 21 00:46:29.011 2009   (  0.00) secs
                     Stale or no data being received from SMT.

   4  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:39.275 2009  to  Thu May 21 00:46:39.275 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   5  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:49.767 2009  to  Thu May 21 00:46:49.767 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:00.438 2009  to  Thu May 21 00:47:00.438 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:11.045 2009  to  Thu May 21 00:47:11.045 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:21.623 2009  to  Thu May 21 00:47:21.623 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   9  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:32.317 2009  to  Thu May 21 00:47:32.317 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:42.898 2009  to  Thu May 21 00:47:42.898 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  11  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:53.526 2009  to  Thu May 21 00:47:53.526 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  12  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:04.021 2009  to  Thu May 21 00:48:04.021 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  13  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:14.622 2009  to  Thu May 21 00:48:14.622 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:25.250 2009  to  Thu May 21 00:48:25.250 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:35.888 2009  to  Thu May 21 00:48:35.888 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:46.481 2009  to  Thu May 21 00:48:46.481 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:57.153 2009  to  Thu May 21 00:48:57.153 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest

   1  STARTUP   ENV        startup                                                       Thu May 21 00:49:39.582 2009  to  Thu May 21 00:49:39.582 2009   (  0.00) secs
                     ENV subsystem started, version 1.0
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.00    0.05    0.05    0.05     0.0 %          1                     1           
                                                                                                   
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    0.00    3.41    3.41    3.41   100.0 %          1          1                      
                                                                       0.00    3.41    3.41    3.41
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    0.00   16.78   16.78   16.78   100.0 %          1          1                      
                                                                       0.00   16.78   16.78   16.78
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    0.00   16.40   16.40   16.40   100.0 %          1          1                      
                                                                       0.00   16.40   16.40   16.40
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    0.00    4.33    4.33    4.33   100.0 %          1          1                      
                                                                       0.00    4.33    4.33    4.33
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.00    0.17    0.17    0.17   100.0 %          1          1                      
                                                                       0.00    0.17    0.17    0.17

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest

   1  STARTUP   GCS        startup                                                       Thu May 21 00:49:51.214 2009  to  Thu May 21 00:49:51.214 2009   (  0.00) secs
                     left GCS subsystem started

   2  STARTUP   GCS        startup                                                       Thu May 21 00:50:00.751 2009  to  Thu May 21 00:50:00.751 2009   (  0.00) secs
                     right GCS subsystem started

   3  STARTUP   GCS        startup                                                       Thu May 21 03:15:14.089 2009  to  Thu May 21 03:15:14.089 2009   (  0.00) secs
                     left GCS subsystem started

   4  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu May 21 05:35:14.265 2009  to  Thu May 21 05:35:14.316 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      34                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      21                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Wed May 20 21:22:07.040 2009  to  Wed May 20 21:22:07.040 2009   (  0.00) secs
                     The LSS was started.

   2  STARTUP   LSS        startup                                                       Thu May 21 00:47:32.209 2009  to  Thu May 21 00:47:32.209 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            80
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      27                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      23                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      33                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             9
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .       9                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .      12                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      15                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      16                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .      43                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 20:17:25.746 2009  to  Wed May 20 20:17:25.746 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 20:17:25.761 2009  to  Wed May 20 20:17:25.761 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Wed May 20 20:17:26.799 2009  to  Wed May 20 20:17:26.799 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 23:11:12.825 2009  to  Wed May 20 23:11:12.825 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 23:11:12.827 2009  to  Wed May 20 23:11:12.827 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Wed May 20 23:11:13.884 2009  to  Wed May 20 23:11:13.884 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed May 20 23:22:33.895 2009  to  Wed May 20 23:22:33.895 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   8  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Thu May 21 00:32:45.948 2009  to  Thu May 21 00:32:45.948 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    0.00   17.03   17.03   17.03   100.0 %          1          1                      
                                                                       0.00   17.03   17.03   17.03
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .   18.24   13.25    2.35   34.31   100.0 %          3          3                      
                                                                      18.24   13.25    2.35   34.31
     side[0].tertiary_mirror.getfocalstationcount.command . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.44   23.21   22.90   23.52   100.0 %          2          2                      
                                                                       0.44   23.21   22.90   23.52
     side[0].tertiary_mirror.moveselabs.command . . . . . . . . . .    0.00   17.74   17.74   17.74   100.0 %          1          1                      
                                                                       0.00   17.74   17.74   17.74

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Thu May 21 00:47:49.689 2009  to  Thu May 21 00:47:49.689 2009   (  0.00) secs
                     The oss was started.

   2  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu May 21 04:30:40.774 2009  to  Thu May 21 04:30:40.774 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

   3  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu May 21 04:30:41.826 2009  to  Thu May 21 04:30:41.826 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.01    0.05    0.05    0.07   100.0 %          9          9                      
                                                                       0.01    0.05    0.05    0.07
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.22    0.66    0.32    0.83   100.0 %          9          9                      
                                                                       0.22    0.66    0.32    0.83
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.07    0.07    0.00    0.16   100.0 %          5          5                      
                                                                       0.05    0.11    0.06    0.16

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Thu May 21 00:49:35.962 2009  to  Thu May 21 00:49:35.962 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35a

   2  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:06:08.118 2009  to  Thu May 21 03:06:08.125 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   3  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:06:08.189 2009  to  Thu May 21 03:06:08.189 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   4  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:15:49.261 2009  to  Thu May 21 03:15:49.264 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   5  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:15:49.458 2009  to  Thu May 21 03:15:49.458 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.37    0.37    0.37   100.0 %          1          1                      
                                                                       0.00    0.37    0.37    0.37
     mirror.command.elevFlag. . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    0.00   70.16   70.16   70.16   100.0 %          1          1                      
                                                                       0.00   70.16   70.16   70.16

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      30                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  6           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       4                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       4                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       4                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       4                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       4                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       4                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       4                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            13
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             2
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           

PMC Events of Interest

   1  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:48:06.324 2009  to  Thu May 21 00:48:06.324 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   2  STARTUP   PMC        startup                                                       Thu May 21 00:48:09.648 2009  to  Thu May 21 00:48:09.648 2009   (  0.00) secs
                     right PMC subsystem started, version 4.13

   3  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:48:17.907 2009  to  Thu May 21 00:48:17.907 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

   4  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:49:44.236 2009  to  Thu May 21 00:49:44.236 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   5  STARTUP   PMC        startup                                                       Thu May 21 00:49:47.684 2009  to  Thu May 21 00:49:47.684 2009   (  0.00) secs
                     left PMC subsystem started, version 4.13

   6  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:49:53.108 2009  to  Thu May 21 00:49:53.108 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

   7  SHUTDOWN  PMC        shutdown                                                      Thu May 21 04:37:24.732 2009  to  Thu May 21 04:37:24.732 2009   (  0.00) secs
                     right PMC subsystem shut down

   8  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.783 2009  to  Thu May 21 04:37:24.783 2009   (  0.00) secs
                     right PMC PMC closing network connection

   9  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.884 2009  to  Thu May 21 04:37:24.884 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

  10  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.935 2009  to  Thu May 21 04:37:24.935 2009   (  0.00) secs
                     right PMC Async closing network connection

  11  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.037 2009  to  Thu May 21 04:37:25.037 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  12  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.088 2009  to  Thu May 21 04:37:25.088 2009   (  0.00) secs
                     right PMC Mount closing network connection

  13  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.189 2009  to  Thu May 21 04:37:25.189 2009   (  0.00) secs
                     right PMC Mirror closing network connection

  14  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.291 2009  to  Thu May 21 04:37:25.291 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  15  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.393 2009  to  Thu May 21 04:37:25.393 2009   (  0.00) secs
                     right PMC Motor closing network connection

  16  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.495 2009  to  Thu May 21 04:37:25.495 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

  17  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.547 2009  to  Thu May 21 04:37:25.547 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  18  FAILED    PMC        actuator.telemetryError                                       Thu May 21 04:38:04.456 2009  to  Thu May 21 04:38:04.456 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  19  STARTUP   PMC        startup                                                       Thu May 21 04:38:08.027 2009  to  Thu May 21 04:38:08.027 2009   (  0.00) secs
                     right PMC subsystem started, version 4.13

  20  FAILED    PMC        actuator.telemetryError                                       Thu May 21 04:38:18.311 2009  to  Thu May 21 04:38:18.311 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.27    0.27    0.27   100.0 %          1          1                      
                                                                       0.00    0.27    0.27    0.27
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.20    0.15    0.05    0.45    75.0 %          4          3          1           
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    0.00   70.28   70.28   70.28   100.0 %          1          1                      
                                                                       0.00   70.28   70.28   70.28
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.11    0.99    0.92    1.07   100.0 %          2          2                      
                                                                       0.11    0.99    0.92    1.07
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.13    0.24    0.09    0.34    33.3 %          3          1          2           
                                                                       0.00    0.29    0.29    0.29
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.12    0.81    0.72    0.89   100.0 %          2          2                      
                                                                       0.12    0.81    0.72    0.89
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    0.00   17.14   17.14   17.14   100.0 %          1          1                      
                                                                       0.00   17.14   17.14   17.14
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.13    0.74    0.65    0.83   100.0 %          2          2                      
                                                                       0.13    0.74    0.65    0.83
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.20    0.30    0.08    0.44   100.0 %          3          3                      
                                                                       0.20    0.30    0.08    0.44
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .   18.24   13.36    2.46   34.42   100.0 %          3          3                      
                                                                      18.24   13.36    2.46   34.42
     tertiaryMirror.command.enableRzCollimation . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.01    0.10    0.09    0.10   100.0 %          2          2                      
                                                                       0.01    0.10    0.09    0.10
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.15    0.23    0.07    0.36   100.0 %          3          3                      
                                                                       0.15    0.23    0.07    0.36

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  STARTUP   PSF        startup                                                       Thu May 21 00:49:49.338 2009  to  Thu May 21 00:49:49.338 2009   (  0.00) secs
                     left PSF subsystem started, version 4.34

   2  STARTUP   PSF        startup                                                       Thu May 21 00:49:59.154 2009  to  Thu May 21 00:49:59.154 2009   (  0.00) secs
                     right PSF subsystem started, version 4.34

   3  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu May 21 00:50:01.695 2009  to  Thu May 21 00:50:02.039 2009   (  0.34) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   4  FAILED    PSF        command.setNewInstrument                                      Thu May 21 03:06:08.376 2009  to  Thu May 21 03:06:08.822 2009   (  0.45) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

   5  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu May 21 03:06:08.426 2009  to  Thu May 21 03:06:08.520 2009   (  0.09) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  STARTUP   LSS        startup                                                       Wed May 20 21:22:07.040 2009  to  Wed May 20 21:22:07.040 2009   (  0.00) secs
                     The LSS was started.

   2  FAILED    IIF        command.authorize                                             Wed May 20 21:32:15.289 2009  to  Wed May 20 21:32:15.341 2009   (  0.05) secs
                     IIF Authorize command started for left MAT at prime focus (IIF left side)
                     IIF Authorize command failed for left MAT at prime focus (IIF left side)

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:18.493 2009  to  Thu May 21 00:46:18.493 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   4  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:28.678 2009  to  Thu May 21 00:46:28.678 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   5  FAILED    ECS        weatherStation.noWeatherData                                  Thu May 21 00:46:29.011 2009  to  Thu May 21 00:46:29.011 2009   (  0.00) secs
                     Stale or no data being received from SMT.

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:39.275 2009  to  Thu May 21 00:46:39.275 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:46:49.767 2009  to  Thu May 21 00:46:49.767 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:00.438 2009  to  Thu May 21 00:47:00.438 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   9  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:11.045 2009  to  Thu May 21 00:47:11.045 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:21.623 2009  to  Thu May 21 00:47:21.623 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  11  STARTUP   IIF        startup                                                       Thu May 21 00:47:22.083 2009  to  Thu May 21 00:47:22.083 2009   (  0.00) secs
                     IIF subsystem started

  12  STARTUP   LSS        startup                                                       Thu May 21 00:47:32.209 2009  to  Thu May 21 00:47:32.209 2009   (  0.00) secs
                     The LSS was started.

  13  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:32.317 2009  to  Thu May 21 00:47:32.317 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:42.898 2009  to  Thu May 21 00:47:42.898 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  15  STARTUP   OSS        startup                                                       Thu May 21 00:47:49.689 2009  to  Thu May 21 00:47:49.689 2009   (  0.00) secs
                     The oss was started.

  16  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:47:53.526 2009  to  Thu May 21 00:47:53.526 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:04.021 2009  to  Thu May 21 00:48:04.021 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  18  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:48:06.324 2009  to  Thu May 21 00:48:06.324 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  19  STARTUP   PMC        startup                                                       Thu May 21 00:48:09.648 2009  to  Thu May 21 00:48:09.648 2009   (  0.00) secs
                     right PMC subsystem started, version 4.13

  20  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:14.622 2009  to  Thu May 21 00:48:14.622 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  21  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:48:17.907 2009  to  Thu May 21 00:48:17.907 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  22  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:25.250 2009  to  Thu May 21 00:48:25.250 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  23  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:35.888 2009  to  Thu May 21 00:48:35.888 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  24  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:46.481 2009  to  Thu May 21 00:48:46.481 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  25  FAILED    ECS        instrumentCooling.badPMCData                                  Thu May 21 00:48:57.153 2009  to  Thu May 21 00:48:57.153 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  26  STARTUP   PCS        startup                                                       Thu May 21 00:49:35.962 2009  to  Thu May 21 00:49:35.962 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35a

  27  STARTUP   ENV        startup                                                       Thu May 21 00:49:39.582 2009  to  Thu May 21 00:49:39.582 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

  28  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:49:44.236 2009  to  Thu May 21 00:49:44.236 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  29  STARTUP   PMC        startup                                                       Thu May 21 00:49:47.684 2009  to  Thu May 21 00:49:47.684 2009   (  0.00) secs
                     left PMC subsystem started, version 4.13

  30  STARTUP   PSF        startup                                                       Thu May 21 00:49:49.338 2009  to  Thu May 21 00:49:49.338 2009   (  0.00) secs
                     left PSF subsystem started, version 4.34

  31  STARTUP   GCS        startup                                                       Thu May 21 00:49:51.214 2009  to  Thu May 21 00:49:51.214 2009   (  0.00) secs
                     left GCS subsystem started

  32  FAILED    PMC        actuator.telemetryError                                       Thu May 21 00:49:53.108 2009  to  Thu May 21 00:49:53.108 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  33  STARTUP   PSF        startup                                                       Thu May 21 00:49:59.154 2009  to  Thu May 21 00:49:59.154 2009   (  0.00) secs
                     right PSF subsystem started, version 4.34

  34  STARTUP   GCS        startup                                                       Thu May 21 00:50:00.751 2009  to  Thu May 21 00:50:00.751 2009   (  0.00) secs
                     right GCS subsystem started

  35  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu May 21 00:50:01.695 2009  to  Thu May 21 00:50:02.039 2009   (  0.34) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  36  FAILED    IIF GUI    IIFCommand.authorize                                          Thu May 21 03:06:07.986 2009  to  Thu May 21 03:06:32.610 2009   ( 24.62) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  37  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:06:08.118 2009  to  Thu May 21 03:06:08.125 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  38  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:06:08.189 2009  to  Thu May 21 03:06:08.189 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  39  FAILED    PSF        command.setNewInstrument                                      Thu May 21 03:06:08.376 2009  to  Thu May 21 03:06:08.822 2009   (  0.45) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

  40  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu May 21 03:06:08.426 2009  to  Thu May 21 03:06:08.520 2009   (  0.09) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  41  STARTUP   GCS        startup                                                       Thu May 21 03:15:14.089 2009  to  Thu May 21 03:15:14.089 2009   (  0.00) secs
                     left GCS subsystem started

  42  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:15:49.261 2009  to  Thu May 21 03:15:49.264 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  43  SEQERROR  PCS        telescope.command.stopTracking                                Thu May 21 03:15:49.458 2009  to  Thu May 21 03:15:49.458 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 20:17:25.746 2009  to  Wed May 20 20:17:25.746 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 20:17:25.761 2009  to  Wed May 20 20:17:25.761 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  46  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Wed May 20 20:17:26.799 2009  to  Wed May 20 20:17:26.799 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  47  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu May 21 04:30:40.774 2009  to  Thu May 21 04:30:40.774 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

  48  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu May 21 04:30:41.826 2009  to  Thu May 21 04:30:41.826 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete

  49  SHUTDOWN  PMC        shutdown                                                      Thu May 21 04:37:24.732 2009  to  Thu May 21 04:37:24.732 2009   (  0.00) secs
                     right PMC subsystem shut down

  50  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.783 2009  to  Thu May 21 04:37:24.783 2009   (  0.00) secs
                     right PMC PMC closing network connection

  51  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.884 2009  to  Thu May 21 04:37:24.884 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

  52  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:24.935 2009  to  Thu May 21 04:37:24.935 2009   (  0.00) secs
                     right PMC Async closing network connection

  53  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.037 2009  to  Thu May 21 04:37:25.037 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  54  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.088 2009  to  Thu May 21 04:37:25.088 2009   (  0.00) secs
                     right PMC Mount closing network connection

  55  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.189 2009  to  Thu May 21 04:37:25.189 2009   (  0.00) secs
                     right PMC Mirror closing network connection

  56  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.291 2009  to  Thu May 21 04:37:25.291 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  57  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.393 2009  to  Thu May 21 04:37:25.393 2009   (  0.00) secs
                     right PMC Motor closing network connection

  58  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.495 2009  to  Thu May 21 04:37:25.495 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

  59  FAILED    PMC        VxInterface.close                                             Thu May 21 04:37:25.547 2009  to  Thu May 21 04:37:25.547 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  60  FAILED    PMC        actuator.telemetryError                                       Thu May 21 04:38:04.456 2009  to  Thu May 21 04:38:04.456 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  61  STARTUP   PMC        startup                                                       Thu May 21 04:38:08.027 2009  to  Thu May 21 04:38:08.027 2009   (  0.00) secs
                     right PMC subsystem started, version 4.13

  62  FAILED    PMC        actuator.telemetryError                                       Thu May 21 04:38:18.311 2009  to  Thu May 21 04:38:18.311 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  63  FAILED    IIF        command.preset.(GUIDE)                                        Thu May 21 05:33:18.346 2009  to  Thu May 21 05:35:14.555 2009   (116.21) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  64  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu May 21 05:35:14.265 2009  to  Thu May 21 05:35:14.316 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

  65  FAILED    IIF        command.authorize                                             Thu May 21 05:44:36.075 2009  to  Thu May 21 05:44:36.127 2009   (  0.05) secs
                     IIF Authorize command started for left MAT at prime focus (IIF left side)
                     IIF Authorize command failed for left MAT at prime focus (IIF left side)

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 23:11:12.825 2009  to  Wed May 20 23:11:12.825 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed May 20 23:11:12.827 2009  to  Wed May 20 23:11:12.827 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  68  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Wed May 20 23:11:13.884 2009  to  Wed May 20 23:11:13.884 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  69  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed May 20 23:22:33.895 2009  to  Wed May 20 23:22:33.895 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  70  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Thu May 21 00:32:45.948 2009  to  Thu May 21 00:32:45.948 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

**********************************************************
    Reporting period ending:   Thu May 21 00:33:57.203 2009
********************************************************************************************************

This topic: Software > TCSSWReportFile_090520
Topic revision: 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback