You are here: Foswiki>Software Web>TCSSWReportFile_090512 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 12 2009 to May 13 2009
 
    Reporting period beginning:   Tue May 12 18:49:30.070 2009
    Reporting period ending:      Wed May 13 05:51:49.487 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = aos.command.shutdown.done,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.41    0.55    0.28    1.38    83.3 %          6          5          1           
                                                                       0.07    0.39    0.28    0.44

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 12 18:56:29.409 2009  to  Tue May 12 18:56:30.791 2009   (  1.38) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.move . . . . . . . . . . . . . . . . . . . . . . . . .    4.76    6.07    1.27   18.63   100.0 %         31         31                      
                                                                       4.76    6.07    1.27   18.63
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    3.46   17.05    9.42   26.38    99.2 %        118        117                     1
                                                                       3.46   17.05    9.42   26.38
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.98    3.20    1.66    5.46   100.0 %        118        118                      
                                                                       0.98    3.20    1.66    5.46
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   60.84   58.45    3.08  164.07    87.5 %          8          7          1           
                                                                      61.11   66.36   16.63  164.07
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   22.70   54.09    2.29  245.68    93.2 %        133        113          9         11
                                                                      21.25   56.18   30.12  245.68
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    5.30    2.92    2.07   51.14   100.0 %        136        136                      
                                                                       5.30    2.92    2.07   51.14
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   18.08    6.10    2.07  146.31   100.0 %        135        135                      
                                                                      18.08    6.10    2.07  146.31

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             5
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             3

IIF Events of Interest

   1  STARTUP   IIF        startup                                                       Tue May 12 20:03:24.364 2009  to  Tue May 12 20:03:24.364 2009   (  0.00) secs
                     IIF subsystem started

   2  FAILED    IIF        command.preset.(ACQUIRE)                                      Tue May 12 20:06:41.000 2009  to  Tue May 12 20:06:44.079 2009   (  3.08) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGw command status: AGW2: Axes had not been homed, yet
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGw command status: AGW2: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -3.0397e-08, 0.177361, 30.9876 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   3  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:17:36.170 2009  to  Tue May 12 21:17:38.892 2009   (  2.72) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -195.818, 86.41, 11.0561 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   4  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:22:45.093 2009  to  Tue May 12 21:23:11.546 2009   ( 26.45) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   5  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:53:59.641 2009  to  Tue May 12 21:54:05.977 2009   (  6.34) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -193.591, 74.5469, 12.4031 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   6  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:33:41.819 2009  to  Tue May 12 22:34:37.766 2009   ( 55.95) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   7  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:35:51.082 2009  to  Tue May 12 22:36:26.901 2009   ( 35.82) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   8  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:37:39.712 2009  to  Tue May 12 22:38:14.312 2009   ( 34.60) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   9  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:44:22.208 2009  to  Tue May 12 22:45:36.992 2009   ( 74.78) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  10  FAILED    IIF        command.preset.(ACTIVE)                                       Wed May 13 04:29:35.146 2009  to  Wed May 13 04:29:46.828 2009   ( 11.68) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -173.46, 80.3089, 15.5558 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  11  FAILED    IIF        command.preset.(ACTIVE)                                       Wed May 13 04:31:01.695 2009  to  Wed May 13 04:31:03.986 2009   (  2.29) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -183.369, 71.9957, 14.4542 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest

   1  STARTUP   AOS        startup                                                       Tue May 12 20:24:21.499 2009  to  Tue May 12 20:24:21.499 2009   (  0.00) secs
                     AOS subsystem started - AOS Version .

   2  SHUTDOWN  AOS        command.shutdown                                              Tue May 12 20:24:41.922 2009  to  Tue May 12 20:24:41.922 2009   (  0.00) secs
                    

   3  SHUTDOWN  AOS        shutdown                                                      Tue May 12 20:24:41.973 2009  to  Tue May 12 20:24:41.973 2009   (  0.00) secs
                     AOS subsystem shut down - AOS Version .
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                    99.7 %                  3341         11           
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6682          2           
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 10           
     weatherStation.noWeatherData . . . . . . . . . . . . . . . . .                  2           
     plc.read.failed. . . . . . . . . . . . . . . . . . . . . . . .                 18           
     plc.writeHS.failed . . . . . . . . . . . . . . . . . . . . . .                 23           
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      30                      

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 18:51:14.098 2009  to  Tue May 12 18:51:14.098 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        weatherStation.noWeatherData                                  Tue May 12 18:51:24.619 2009  to  Tue May 12 18:51:24.619 2009   (  0.00) secs
                     Stale or no data being received from SMT.

   3  FAILED    ECS        plc.read.failed                                               Tue May 12 18:54:19.868 2009  to  Tue May 12 18:54:19.868 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

   4  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 18:57:28.856 2009  to  Tue May 12 18:57:28.856 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0577999e+01, because Not Connected to PLC

   5  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 18:57:28.915 2009  to  Tue May 12 18:57:28.915 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.8999996e-01

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 18:57:39.059 2009  to  Tue May 12 18:57:39.059 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:00:37.844 2009  to  Tue May 12 19:00:37.844 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component SM_DELAY, value 2, because Not Connected to PLC

   8  FAILED    ECS        plc.read.failed                                               Tue May 12 19:03:46.832 2009  to  Tue May 12 19:03:46.832 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

   9  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:06:55.820 2009  to  Tue May 12 19:06:55.820 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0671600e+01, because Not Connected to PLC

  10  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:06:55.882 2009  to  Tue May 12 19:06:55.882 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.3799992e-01

  11  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:07:05.966 2009  to  Tue May 12 19:07:05.966 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  12  FAILED    ECS        plc.read.failed                                               Tue May 12 19:10:04.809 2009  to  Tue May 12 19:10:04.809 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  13  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:13:13.797 2009  to  Tue May 12 19:13:13.797 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0689600e+01, because Not Connected to PLC

  14  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:13:13.873 2009  to  Tue May 12 19:13:13.873 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.2799969e-01

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:13:23.962 2009  to  Tue May 12 19:13:23.962 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        plc.read.failed                                               Tue May 12 19:16:22.786 2009  to  Tue May 12 19:16:22.786 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  17  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:19:31.774 2009  to  Tue May 12 19:19:31.774 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0712999e+01, because Not Connected to PLC

  18  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:19:31.839 2009  to  Tue May 12 19:19:31.839 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.1500015e-01

  19  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:19:41.934 2009  to  Tue May 12 19:19:41.934 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  20  FAILED    ECS        plc.read.failed                                               Tue May 12 19:22:40.763 2009  to  Tue May 12 19:22:40.763 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  21  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:25:49.812 2009  to  Tue May 12 19:25:49.812 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.0600033e-01

  22  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:25:49.751 2009  to  Tue May 12 19:25:49.751 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0729198e+01, because Not Connected to PLC

  23  FAILED    ECS        plc.read.failed                                               Tue May 12 19:28:58.740 2009  to  Tue May 12 19:28:58.740 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  24  FAILED    ECS        plc.read.failed                                               Tue May 12 19:32:07.896 2009  to  Tue May 12 19:32:07.896 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  25  FAILED    ECS        plc.read.failed                                               Tue May 12 19:35:17.051 2009  to  Tue May 12 19:35:17.051 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  26  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:42:43.595 2009  to  Tue May 12 19:42:43.595 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  27  FAILED    ECS        weatherStation.noWeatherData                                  Tue May 12 19:42:54.121 2009  to  Tue May 12 19:42:54.121 2009   (  0.00) secs
                     Stale or no data being received from SMT.

  28  FAILED    ECS        plc.read.failed                                               Tue May 12 19:45:52.320 2009  to  Tue May 12 19:45:52.320 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  29  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:49:01.379 2009  to  Tue May 12 19:49:01.379 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.9600010e-01

  30  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:49:01.321 2009  to  Tue May 12 19:49:01.321 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0747200e+01, because Not Connected to PLC

  31  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:49:11.459 2009  to  Tue May 12 19:49:11.459 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  32  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:52:10.322 2009  to  Tue May 12 19:52:10.322 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component SM_DELAY, value 2, because Not Connected to PLC

  33  FAILED    ECS        plc.read.failed                                               Tue May 12 19:55:19.324 2009  to  Tue May 12 19:55:19.324 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  34  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:58:28.325 2009  to  Tue May 12 19:58:28.325 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0808401e+01, because Not Connected to PLC

  35  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:58:28.381 2009  to  Tue May 12 19:58:28.381 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.6199970e-01

  36  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:58:38.457 2009  to  Tue May 12 19:58:38.457 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  37  FAILED    ECS        plc.read.failed                                               Tue May 12 20:01:37.327 2009  to  Tue May 12 20:01:37.327 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  38  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:04:46.328 2009  to  Tue May 12 20:04:46.328 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0826399e+01, because Not Connected to PLC

  39  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:04:46.391 2009  to  Tue May 12 20:04:46.391 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.5200043e-01

  40  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 20:04:56.489 2009  to  Tue May 12 20:04:56.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  41  FAILED    ECS        plc.read.failed                                               Tue May 12 20:07:55.330 2009  to  Tue May 12 20:07:55.330 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  42  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:11:04.332 2009  to  Tue May 12 20:11:04.332 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0857000e+01, because Not Connected to PLC

  43  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:11:04.413 2009  to  Tue May 12 20:11:04.413 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.3500023e-01

  44  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 20:11:14.489 2009  to  Tue May 12 20:11:14.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  45  FAILED    ECS        plc.read.failed                                               Tue May 12 20:14:13.334 2009  to  Tue May 12 20:14:13.334 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  46  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:17:22.335 2009  to  Tue May 12 20:17:22.335 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0875000e+01, because Not Connected to PLC

  47  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:17:22.401 2009  to  Tue May 12 20:17:22.401 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.2500000e-01

  48  FAILED    ECS        plc.read.failed                                               Tue May 12 20:20:31.337 2009  to  Tue May 12 20:20:31.337 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  49  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:23:40.339 2009  to  Tue May 12 20:23:40.339 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  50  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:26:49.340 2009  to  Tue May 12 20:26:49.340 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  51  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:29:58.340 2009  to  Tue May 12 20:29:58.340 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_LEFT, value 4.8496403e+01, because Not Connected to PLC

  52  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue May 12 20:29:58.393 2009  to  Tue May 12 20:29:58.393 2009   (  0.00) secs
                     Instrument cooling command set temperature set pt failed:temp 9.1646671e+00

  53  FAILED    ECS        plc.read.failed                                               Tue May 12 20:33:07.341 2009  to  Tue May 12 20:33:07.341 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  54  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:36:16.342 2009  to  Tue May 12 20:36:16.342 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  55  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:39:25.343 2009  to  Tue May 12 20:39:25.343 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  56  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue May 12 20:42:34.397 2009  to  Tue May 12 20:42:34.397 2009   (  0.00) secs
                     Instrument cooling command set temperature set pt failed:temp 9.3906670e+00

  57  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:42:34.344 2009  to  Tue May 12 20:42:34.344 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_RIGHT, value 4.8903202e+01, because Not Connected to PLC

  58  FAILED    ECS        plc.read.failed                                               Tue May 12 20:45:43.345 2009  to  Tue May 12 20:45:43.345 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  59  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:48:52.346 2009  to  Tue May 12 20:48:52.346 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  60  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:52:01.347 2009  to  Tue May 12 20:52:01.347 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  61  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:55:10.403 2009  to  Tue May 12 20:55:10.403 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.1299992e-01

  62  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:55:10.347 2009  to  Tue May 12 20:55:10.347 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0896601e+01, because Not Connected to PLC

  63  FAILED    ECS        plc.read.failed                                               Tue May 12 20:58:19.348 2009  to  Tue May 12 20:58:19.348 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  64  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 21:01:28.349 2009  to  Tue May 12 21:01:28.349 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  65  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 21:04:37.350 2009  to  Tue May 12 21:04:37.350 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  66  FAILED    ECS        plc.read.failed                                               Tue May 12 21:07:46.350 2009  to  Tue May 12 21:07:46.350 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC
**********************************************************
ENV Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest

   1  STARTUP   ENV        startup                                                       Tue May 12 20:19:42.910 2009  to  Tue May 12 20:19:42.910 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

   2  SHUTDOWN  ENV        command.shutdown                                              Tue May 12 20:20:37.111 2009  to  Tue May 12 20:20:37.111 2009   (  0.00) secs
                     ENV shutdown command started

   3  SHUTDOWN  ENV        command.shutdown                                              Tue May 12 20:20:37.358 2009  to  Tue May 12 20:20:37.358 2009   (  0.00) secs
                     Env shutdown command complete

   4  SHUTDOWN  ENV        shutdown                                                      Tue May 12 20:20:37.409 2009  to  Tue May 12 20:20:37.409 2009   (  0.00) secs
                     ENV subsystem shut down
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       9
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    4.93   20.60    0.00   40.58    99.2 %        129        125          1          3
                                                                       4.61   20.44    0.00   26.31
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    1.34    0.45    0.00   10.12    98.4 %        129        250          4           
                                                                       0.61    0.30    0.00    5.03
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    0.18    6.98    6.84    7.24   100.0 %          4          4                      
                                                                       0.18    6.98    6.84    7.24
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.getEffectiveGuideRate. . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .    8.29    6.78    1.85   22.37    75.0 %         44                    11           
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .    0.00    3.25    3.25    3.26    75.0 %          8                     2           
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         92                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getMaximumGuideRate. . . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         20                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    0.81    8.40    6.94   11.76   100.0 %        116        116                      
                                                                       0.81    8.40    6.94   11.76
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.47    0.48    0.08    2.17   100.0 %        116        116                      
                                                                       0.47    0.48    0.08    2.17
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    1.27    4.14    0.00    8.09   100.0 %        116        116                     1
                                                                       1.27    4.14    0.00    8.09
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .   14.84   10.18    0.00   50.18    85.0 %         20         13          3           
                                                                      13.05    7.45    0.00   50.18
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         88                                 
                                                                                                   
     command.setGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    5.83   14.54    0.00   34.57    96.5 %        141        141          5           
                                                                       5.43   14.97    0.00   34.57
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          7                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.17   100.0 %        124        124                      
                                                                       0.01    0.06    0.04    0.17
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.05    0.07   100.0 %          7          7                      
                                                                       0.00    0.06    0.05    0.07
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.79    0.98    0.17    4.82    82.7 %        150        124                      
                                                                       0.79    0.98    0.17    4.82
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.45    0.25    0.15    4.30   100.0 %        124        124                      
                                                                       0.45    0.25    0.15    4.30
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    2.30    8.57    0.30   20.97    98.1 %        257        252          5           
                                                                       2.03    8.73    6.37   20.97
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.76    2.14    0.48   12.76    98.0 %       5444       5336                        interrupted =   107
                                                                       1.76    2.14    0.48   12.76
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    7.46   31.17   17.32   49.87    64.4 %        458        295                        interrupted =   163
                                                                       7.46   31.17   17.32   49.87
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.02    0.19    0.15    0.34   100.0 %        257        257                      
                                                                       0.02    0.19    0.15    0.34
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    3.24    0.28    0.14  216.74   100.0 %       5074       5074                        interrupted =     4
                                                                       3.24    0.28    0.14  216.74
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.55    2.08    1.18    4.51   100.0 %        125        125                      
                                                                       0.55    2.08    1.18    4.51
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   24.09   19.31    5.03  354.70   100.0 %        281        281                      
                                                                      24.09   19.31    5.03  354.70
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.41    4.32    3.60    6.20    96.9 %        294        285                      
                                                                       0.41    4.32    3.60    6.20

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .     125                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .     124                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .     124                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .     125                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                           138

GCS Events of Interest

   1  STARTUP   GCS        startup                                                       Tue May 12 19:09:07.500 2009  to  Tue May 12 19:09:07.500 2009   (  0.00) secs
                     left GCS subsystem started

   2  STARTUP   GCS        startup                                                       Tue May 12 20:13:24.747 2009  to  Tue May 12 20:13:24.747 2009   (  0.00) secs
                     left GCS subsystem started

   3  STARTUP   GCS        startup                                                       Tue May 12 20:41:43.126 2009  to  Tue May 12 20:41:43.126 2009   (  0.00) secs
                     left GCS subsystem started

   4  STARTUP   GCS        startup                                                       Tue May 12 20:52:23.694 2009  to  Tue May 12 20:52:23.694 2009   (  0.00) secs
                     left GCS subsystem started

   5  STARTUP   GCS        startup                                                       Tue May 12 21:06:53.257 2009  to  Tue May 12 21:06:53.257 2009   (  0.00) secs
                     left GCS subsystem started

   6  FAILED    GCS        command.setAGW                                                Tue May 12 21:07:02.893 2009  to  Tue May 12 21:07:02.960 2009   (  0.07) secs
                     COULD NOT change active AGW configuration to -u

   7  FAILED    GCS        command.setAGW                                                Tue May 12 18:40:19.841 2009  to  Tue May 12 18:40:49.865 2009   ( 30.02) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

   8  FAILED    GCS        command.setAGW                                                Tue May 12 18:41:27.924 2009  to  Tue May 12 18:42:03.883 2009   ( 35.96) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

   9  SHUTDOWN  GCS        command.shutdown                                              Tue May 12 18:53:41.436 2009  to  Tue May 12 18:53:41.436 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  10  SHUTDOWN  GCS        command.shutdown                                              Tue May 12 18:53:43.183 2009  to  Tue May 12 18:53:43.183 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  11  STARTUP   GCS        startup                                                       Tue May 12 18:53:49.228 2009  to  Tue May 12 18:53:49.228 2009   (  0.00) secs
                     left GCS subsystem started

  12  STARTUP   GCS        startup                                                       Tue May 12 18:56:42.382 2009  to  Tue May 12 18:56:42.382 2009   (  0.00) secs
                     left GCS subsystem started

  13  STARTUP   GCS        startup                                                       Tue May 12 19:05:51.999 2009  to  Tue May 12 19:05:51.999 2009   (  0.00) secs
                     left GCS subsystem started

  14  STARTUP   GCS        startup                                                       Tue May 12 19:26:59.151 2009  to  Tue May 12 19:26:59.151 2009   (  0.00) secs
                     left GCS subsystem started

  15  FAILED    GCS        command.getFullWFImage                                        Tue May 12 19:48:24.143 2009  to  Tue May 12 19:48:27.399 2009   (  3.26) secs
                     AzCam server timed out waiting for full CCD readout

  16  FAILED    GCS        command.getFullWFImage                                        Tue May 12 19:48:46.031 2009  to  Tue May 12 19:48:49.281 2009   (  3.25) secs
                     AzCam server timed out waiting for full CCD readout

  17  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:54:31.568 2009  to  Tue May 12 19:54:33.422 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

  18  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:54:49.846 2009  to  Tue May 12 19:54:51.699 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

  19  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:16.714 2009  to  Tue May 12 19:55:18.571 2009   (  1.86) secs
                     AzCam server timed out waiting for full CCD readout

  20  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:25.491 2009  to  Tue May 12 19:55:27.596 2009   (  2.11) secs
                     AzCam server timed out waiting for full CCD readout

  21  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:44.130 2009  to  Tue May 12 19:55:46.223 2009   (  2.09) secs
                     AzCam server timed out waiting for full CCD readout

  22  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:56:28.608 2009  to  Tue May 12 19:56:30.948 2009   (  2.34) secs
                     AzCam server timed out waiting for full CCD readout

  23  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:56:44.348 2009  to  Tue May 12 19:56:46.932 2009   (  2.58) secs
                     AzCam server timed out waiting for full CCD readout

  24  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:57:32.492 2009  to  Tue May 12 19:57:35.311 2009   (  2.82) secs
                     AzCam server timed out waiting for full CCD readout

  25  FAILED    GCS        command.setGuidestarList                                      Tue May 12 20:06:42.535 2009  to  Tue May 12 20:06:43.756 2009   (  1.22) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  26  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 20:06:42.891 2009  to  Tue May 12 20:06:43.701 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGW2: Axes had not been homed, yet

  27  FAILED    GCS        command.setGuidestarList                                      Tue May 12 21:17:37.667 2009  to  Tue May 12 21:17:38.567 2009   (  0.90) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  28  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 21:17:37.957 2009  to  Tue May 12 21:17:38.512 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGW2: Requested position is Out of Range

  29  FAILED    GCS        command.setGuidestarList                                      Tue May 12 21:54:04.752 2009  to  Tue May 12 21:54:05.654 2009   (  0.90) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  30  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 21:54:05.043 2009  to  Tue May 12 21:54:05.600 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGW2: Requested position is Out of Range

  31  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:34:28.036 2009  to  Tue May 12 22:34:37.593 2009   (  9.56) secs
                     couldn''t find a star in any GS location.

  32  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:36:16.612 2009  to  Tue May 12 22:36:26.731 2009   ( 10.12) secs
                     couldn''t find a star in any GS location.

  33  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:38:04.241 2009  to  Tue May 12 22:38:14.141 2009   (  9.90) secs
                     couldn''t find a star in any GS location.

  34  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:45:27.075 2009  to  Tue May 12 22:45:36.821 2009   (  9.75) secs
                     couldn''t find a star in any GS location.

  35  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:14:41.148 2009  to  Wed May 13 01:14:53.515 2009   ( 12.37) secs
                     request to AzCam server for a full CCD readout failed

  36  FAILED    GCS        command.autoAcquireGuidestar                                  Wed May 13 01:18:35.252 2009  to  Wed May 13 01:19:15.835 2009   ( 40.58) secs
                     guiding was not stable within 6 cycles

  37  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:23:34.981 2009  to  Wed May 13 01:23:57.349 2009   ( 22.37) secs
                     request to AzCam server for a full CCD readout failed

  38  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:30:48.982 2009  to  Wed May 13 01:31:11.349 2009   ( 22.37) secs
                     request to AzCam server for a full CCD readout failed

  39  FAILED    GCS        command.setGuidestarList                                      Wed May 13 04:29:37.946 2009  to  Wed May 13 04:29:46.499 2009   (  8.55) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  40  FAILED    GCS        interface.agw.setProbePosition                                Wed May 13 04:29:45.886 2009  to  Wed May 13 04:29:46.444 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGW2: Requested position is Out of Range

  41  FAILED    GCS        command.setGuidestarList                                      Wed May 13 04:31:03.007 2009  to  Wed May 13 04:31:03.659 2009   (  0.65) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  42  FAILED    GCS        interface.agw.setProbePosition                                Wed May 13 04:31:03.298 2009  to  Wed May 13 04:31:03.602 2009   (  0.30) secs
                     couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGW2: Requested position is Out of Range
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      21                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      18                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Tue May 12 18:49:30.070 2009  to  Tue May 12 18:49:30.070 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            42
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      51                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       6                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      22                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     175                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     282                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     154                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .     141                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     141                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     286                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     351                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    2842                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     922                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 12 18:47:38.745 2009  to  Tue May 12 18:47:38.745 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 12 18:47:38.766 2009  to  Tue May 12 18:47:38.766 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue May 12 18:47:38.862 2009  to  Tue May 12 18:47:38.862 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.871 2009  to  Tue May 12 18:47:39.871 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.871 2009  to  Tue May 12 18:47:39.871 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.872 2009  to  Tue May 12 18:47:39.872 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.872 2009  to  Tue May 12 18:47:39.872 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.873 2009  to  Tue May 12 18:47:39.873 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.873 2009  to  Tue May 12 18:47:39.873 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.874 2009  to  Tue May 12 18:47:39.874 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.874 2009  to  Tue May 12 18:47:39.874 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Wed May 13 05:03:47.961 2009  to  Wed May 13 05:03:47.961 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    2.14    7.68    0.35   18.08   100.0 %        539        539                      
                                                                       2.14    7.68    0.35   18.08

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             1

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Tue May 12 19:03:55.576 2009  to  Tue May 12 19:03:55.576 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.05    0.04    0.09   100.0 %        257        257                      
                                                                       0.00    0.05    0.04    0.09
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.00    0.05    0.03    0.15   100.0 %       5074       5074                      
                                                                       0.00    0.05    0.03    0.15
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.54    1.93    1.05    4.38   100.0 %        125        125                        largeUpdate =   117
                                                                       0.54    1.93    1.05    4.38
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          8          8                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         65         65                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.01    0.05    0.05    0.09   100.0 %         53         53                      
                                                                       0.01    0.05    0.05    0.09
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         20         20                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.01    0.06    0.05    0.14   100.0 %        142        142                      
                                                                       0.01    0.06    0.05    0.14
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.09    0.10    0.05    0.20   100.0 %          3          3                      
                                                                       0.09    0.10    0.05    0.20
     telescope.command.setPointingLog . . . . . . . . . . . . . . .    0.00    0.17    0.17    0.17   100.0 %          1          1                      
                                                                       0.00    0.17    0.17    0.17
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.59    0.31    0.87    99.3 %        142        141          1           
                                                                       0.20    0.58    0.31    0.87
     telescope.command.stopPointingLog. . . . . . . . . . . . . . .    0.00    0.19    0.19    0.19   100.0 %          1          1                      
                                                                       0.00    0.19    0.19    0.19
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.07    0.09    0.00    0.18    75.0 %          8                     2           
                                                                       0.02    0.10    0.07    0.11

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       3                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       3                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Tue May 12 19:57:02.799 2009  to  Tue May 12 19:57:02.799 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

   2  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 20:04:20.192 2009  to  Tue May 12 20:04:20.204 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   3  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 20:04:20.346 2009  to  Tue May 12 20:04:20.346 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   4  FAILED    PCS        telescope.command.startTracking                               Tue May 12 20:08:08.835 2009  to  Tue May 12 20:08:09.655 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

   5  FAILED    PCS        telescope.command.stopTracking                                Tue May 12 20:08:18.787 2009  to  Tue May 12 20:08:18.932 2009   (  0.15) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  FAILED    PCS        telescope.command.stopTracking                                Tue May 12 20:08:34.839 2009  to  Tue May 12 20:08:35.022 2009   (  0.18) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  SHUTDOWN  PCS        shutdown                                                      Tue May 12 20:08:59.501 2009  to  Tue May 12 20:08:59.501 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.35

   8  STARTUP   PCS        startup                                                       Tue May 12 20:09:10.642 2009  to  Tue May 12 20:09:10.642 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

   9  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 18:56:29.601 2009  to  Tue May 12 18:56:29.601 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  10  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 18:56:29.711 2009  to  Tue May 12 18:56:29.711 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          1          1                      
                                                                       0.00    1.05    1.05    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.56    2.23    2.05    6.06   100.0 %        276        276                      
                                                                       0.56    2.23    2.05    6.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00   16.09   16.09   16.09   100.0 %          1          1                      
                                                                       0.00   16.09   16.09   16.09
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    2.89    3.39    0.05    5.06    66.7 %          3          2          1           
                                                                       0.00    5.06    5.05    5.06
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.72    0.72    0.72   100.0 %          1          1                      
                                                                       0.00    0.72    0.72    0.72
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.16   66.16   66.16   100.0 %          1          1                      
                                                                       0.00   66.16   66.16   66.16
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          2          2                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    5.28    4.63    0.05   63.18    99.2 %        259        257          2           
                                                                       5.29    4.67    2.06   63.18
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    0.00   11.07   11.07   11.07   100.0 %          1          1                      
                                                                       0.00   11.07   11.07   11.07
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  102.40  102.40  102.40     0.0 %          1                     1           
                                                                                                   
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.10    0.10    0.10   100.0 %          1          1                      
                                                                       0.00    0.10    0.10    0.10
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.09   100.0 %         10         10                      
                                                                       0.01    0.06    0.05    0.09

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  4           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       3                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       3                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       3                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       3                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       3                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                             9
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      32                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 22           
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                            11
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     276                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 12           
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            13
     actuator.Z.upperLimit.exceeded . . . . . . . . . . . . . . . .                             2
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             2
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                          4137
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             9
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                          3852
     actuator.getForce.readError. . . . . . . . . . . . . . . . . .                  3           
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                             2
     actuator.setForce.addressError . . . . . . . . . . . . . . . .                  4           
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                  4           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                 29           

PMC Events of Interest

   1  FAILED    PMC        actuator.telemetryError                                       Tue May 12 18:58:46.645 2009  to  Tue May 12 18:58:46.645 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   2  STARTUP   PMC        startup                                                       Tue May 12 18:59:16.292 2009  to  Tue May 12 18:59:16.292 2009   (  0.00) secs
                     left PMC subsystem started, version 4.9

   3  FAILED    PMC        actuator.telemetryError                                       Tue May 12 19:33:56.512 2009  to  Tue May 12 19:33:56.512 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

   4  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.400 2009  to  Tue May 12 20:18:11.400 2009   (  0.00) secs
                     left PMC PMC closing network connection

   5  SHUTDOWN  PMC        shutdown                                                      Tue May 12 20:18:11.349 2009  to  Tue May 12 20:18:11.349 2009   (  0.00) secs
                     left PMC subsystem shut down

   6  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.503 2009  to  Tue May 12 20:18:11.503 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

   7  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.554 2009  to  Tue May 12 20:18:11.554 2009   (  0.00) secs
                     left PMC Async closing network connection

   8  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.656 2009  to  Tue May 12 20:18:11.656 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   9  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.757 2009  to  Tue May 12 20:18:11.757 2009   (  0.00) secs
                     left PMC Mount closing network connection

  10  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.859 2009  to  Tue May 12 20:18:11.859 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  11  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.961 2009  to  Tue May 12 20:18:11.961 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  12  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.063 2009  to  Tue May 12 20:18:12.063 2009   (  0.00) secs
                     left PMC Motor closing network connection

  13  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.165 2009  to  Tue May 12 20:18:12.165 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  14  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.217 2009  to  Tue May 12 20:18:12.217 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  15  FAILED    PMC        actuator.telemetryError                                       Tue May 12 20:18:23.053 2009  to  Tue May 12 20:18:23.053 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  16  STARTUP   PMC        startup                                                       Tue May 12 20:18:25.916 2009  to  Tue May 12 20:18:25.916 2009   (  0.00) secs
                     left PMC subsystem started, version 4.9

  17  FAILED    PMC        actuator.telemetryError                                       Tue May 12 20:18:31.109 2009  to  Tue May 12 20:18:31.109 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  18  FAILED    PMC        VxInterface.close                                             Tue May 12 20:20:12.315 2009  to  Tue May 12 20:20:12.315 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:20:12.263 2009  to  Tue May 12 20:20:12.263 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  20  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:21:33.006 2009  to  Tue May 12 20:21:33.006 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Tue May 12 20:21:33.059 2009  to  Tue May 12 20:21:33.059 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:38:34.775 2009  to  Tue May 12 20:38:34.775 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Tue May 12 20:38:34.827 2009  to  Tue May 12 20:38:34.827 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  FAILED    PMC        mirror.panic                                                  Tue May 12 21:22:59.627 2009  to  Tue May 12 21:22:59.627 2009   (  0.00) secs
                     left PMC ** PANIC: Outer loop stalled

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 12 21:23:08.164 2009  to  Tue May 12 21:23:08.217 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  26  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 12 21:25:57.685 2009  to  Tue May 12 21:25:57.787 2009   (  0.10) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  27  FAILED    PMC        mirror.command.raise.auto                                     Tue May 12 21:27:07.988 2009  to  Tue May 12 21:28:50.389 2009   (102.40) secs
                     left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

  28  FAILED    PMC        VxInterface.close                                             Tue May 12 22:37:56.024 2009  to  Tue May 12 22:37:56.024 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  29  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 22:37:55.973 2009  to  Tue May 12 22:37:55.973 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  30  FAILED    PMC        VxInterface.close                                             Tue May 12 23:09:22.997 2009  to  Tue May 12 23:09:22.997 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 23:09:22.944 2009  to  Tue May 12 23:09:22.944 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:04:05.183 2009  to  Wed May 13 00:04:05.183 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Wed May 13 00:04:05.236 2009  to  Wed May 13 00:04:05.236 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:20:03.834 2009  to  Wed May 13 00:20:03.834 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.close                                             Wed May 13 00:20:03.886 2009  to  Wed May 13 00:20:03.886 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:51:21.049 2009  to  Wed May 13 00:51:21.049 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Wed May 13 00:51:21.103 2009  to  Wed May 13 00:51:21.103 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 01:50:38.506 2009  to  Wed May 13 01:50:38.506 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Wed May 13 01:50:38.558 2009  to  Wed May 13 01:50:38.558 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 02:06:46.635 2009  to  Wed May 13 02:06:46.635 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.close                                             Wed May 13 02:06:46.688 2009  to  Wed May 13 02:06:46.688 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  42  FAILED    PMC        mirror.panic                                                  Wed May 13 03:14:56.494 2009  to  Wed May 13 03:14:56.494 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  43  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:56.598 2009  to  Wed May 13 03:14:56.598 2009   (  0.00) secs
                     right PMC Actuator 124 get force read error: -3

  44  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:58.519 2009  to  Wed May 13 03:14:58.519 2009   (  0.00) secs
                     right PMC Actuator 242 get force read error: -3

  45  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:14:58.467 2009  to  Wed May 13 03:14:58.467 2009   (  0.00) secs
                     right PMC Actuator 440 set force bad return: 163 instead of 19

  46  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:14:58.826 2009  to  Wed May 13 03:14:58.826 2009   (  0.00) secs
                     right PMC Actuator 114 set force read error: -3

  47  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:14:59.130 2009  to  Wed May 13 03:14:59.130 2009   (  0.00) secs
                     right PMC Actuator 103 set force bad return: 170 instead of 1

  48  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:59.182 2009  to  Wed May 13 03:14:59.182 2009   (  0.00) secs
                     right PMC Actuator 233 get force read error: -3

  49  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.234 2009  to  Wed May 13 03:14:59.234 2009   (  0.00) secs
                     right PMC Actuator 113 has been reset

  50  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.286 2009  to  Wed May 13 03:14:59.286 2009   (  0.00) secs
                     right PMC Actuator 109 has been reset

  51  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.338 2009  to  Wed May 13 03:14:59.338 2009   (  0.00) secs
                     right PMC Actuator 127 has been reset

  52  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.390 2009  to  Wed May 13 03:14:59.390 2009   (  0.00) secs
                     right PMC Actuator 117 has been reset

  53  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.442 2009  to  Wed May 13 03:14:59.442 2009   (  0.00) secs
                     right PMC Actuator 120 has been reset

  54  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.494 2009  to  Wed May 13 03:14:59.494 2009   (  0.00) secs
                     right PMC Actuator 134 has been reset

  55  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.546 2009  to  Wed May 13 03:14:59.546 2009   (  0.00) secs
                     right PMC Actuator 125 has been reset

  56  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.598 2009  to  Wed May 13 03:14:59.598 2009   (  0.00) secs
                     right PMC Actuator 131 has been reset

  57  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.650 2009  to  Wed May 13 03:14:59.650 2009   (  0.00) secs
                     right PMC Actuator 136 has been reset

  58  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.702 2009  to  Wed May 13 03:14:59.702 2009   (  0.00) secs
                     right PMC Actuator 129 has been reset

  59  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.754 2009  to  Wed May 13 03:14:59.754 2009   (  0.00) secs
                     right PMC Actuator 138 has been reset

  60  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.806 2009  to  Wed May 13 03:14:59.806 2009   (  0.00) secs
                     right PMC Actuator 143 has been reset

  61  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.858 2009  to  Wed May 13 03:14:59.858 2009   (  0.00) secs
                     right PMC Actuator 208 has been reset

  62  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:14:59.910 2009  to  Wed May 13 03:14:59.910 2009   (  0.00) secs
                     right PMC Actuator 121 set force read error: -3

  63  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.962 2009  to  Wed May 13 03:14:59.962 2009   (  0.00) secs
                     right PMC Actuator 130 has been reset

  64  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.015 2009  to  Wed May 13 03:15:00.015 2009   (  0.00) secs
                     right PMC Actuator 124 has been reset

  65  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.067 2009  to  Wed May 13 03:15:00.067 2009   (  0.00) secs
                     right PMC Actuator 137 has been reset

  66  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.119 2009  to  Wed May 13 03:15:00.119 2009   (  0.00) secs
                     right PMC Actuator 126 has been reset

  67  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.171 2009  to  Wed May 13 03:15:00.171 2009   (  0.00) secs
                     right PMC Actuator 142 has been reset

  68  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.223 2009  to  Wed May 13 03:15:00.223 2009   (  0.00) secs
                     right PMC Actuator 212 has been reset

  69  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:15:00.528 2009  to  Wed May 13 03:15:00.528 2009   (  0.00) secs
                     right PMC Actuator 101 set force bad return: 160 instead of 1

  70  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:15:00.580 2009  to  Wed May 13 03:15:00.580 2009   (  0.00) secs
                     right PMC Actuator 133 set force read error: -3

  71  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.632 2009  to  Wed May 13 03:15:00.632 2009   (  0.00) secs
                     right PMC Actuator 333 has been reset

  72  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.684 2009  to  Wed May 13 03:15:00.684 2009   (  0.00) secs
                     right PMC Actuator 419 has been reset

  73  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.736 2009  to  Wed May 13 03:15:00.736 2009   (  0.00) secs
                     right PMC Actuator 407 has been reset

  74  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.788 2009  to  Wed May 13 03:15:00.788 2009   (  0.00) secs
                     right PMC Actuator 422 has been reset

  75  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.840 2009  to  Wed May 13 03:15:00.840 2009   (  0.00) secs
                     right PMC Actuator 413 has been reset

  76  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.892 2009  to  Wed May 13 03:15:00.892 2009   (  0.00) secs
                     right PMC Actuator 427 has been reset

  77  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:15:01.205 2009  to  Wed May 13 03:15:01.205 2009   (  0.00) secs
                     right PMC Actuator 209 set force bad return: 0 instead of 6

  78  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:15:01.153 2009  to  Wed May 13 03:15:01.153 2009   (  0.00) secs
                     right PMC Actuator 140 set force read error: -3

  79  FAILED    PMC        command.recoverPanic                                          Wed May 13 03:15:04.580 2009  to  Wed May 13 03:15:04.633 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

  80  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 03:55:35.862 2009  to  Wed May 13 03:55:35.862 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  81  FAILED    PMC        VxInterface.close                                             Wed May 13 03:55:35.914 2009  to  Wed May 13 03:55:35.914 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.close                                             Wed May 13 04:01:53.956 2009  to  Wed May 13 04:01:53.956 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  83  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 04:01:53.904 2009  to  Wed May 13 04:01:53.904 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.07   13.76    4.70   47.49   100.0 %        281        281                      
                                                                       3.07   13.76    4.70   47.49
     command.move . . . . . . . . . . . . . . . . . . . . . . . . .    4.75    5.91    1.13   18.44   100.0 %         31         31                      
                                                                       4.75    5.91    1.13   18.44
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    1.94    0.84    0.27   15.78   100.0 %        245        245                      
                                                                       1.94    0.84    0.27   15.78
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.50    0.50    0.50     0.0 %          1                     1           
                                                                                                   
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.07   13.87    4.81   47.60   100.0 %        281        281                      
                                                                       3.07   13.87    4.81   47.60
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.75    5.08    0.19   37.69   100.0 %        281        281                      
                                                                       2.75    5.08    0.19   37.69
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    5.28    4.78    0.22   63.31    99.2 %        259        257          2           
                                                                       5.28    4.81    2.18   63.31
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.01    2.20    2.19    2.20   100.0 %          2          2                      
                                                                       0.01    2.20    2.19    2.20
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00   16.26   16.26   16.26   100.0 %          1          1                      
                                                                       0.00   16.26   16.26   16.26
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.07    0.12    0.07    1.32   100.0 %       2338       2338                      
                                                                       0.07    0.12    0.07    1.32
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.11    0.18    0.10    0.26    50.0 %          2          1          1           
                                                                       0.00    0.26    0.26    0.26
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.00    0.80    0.80    0.80   100.0 %          1          1                      
                                                                       0.00    0.80    0.80    0.80
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    0.58    2.54    2.29    4.32   100.0 %         14         14                      
                                                                       0.58    2.54    2.29    4.32
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.08   100.0 %        245        245                      
                                                                       0.00    0.05    0.05    0.08
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    0.36    0.36    0.36     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.03    0.06    0.05    0.58   100.0 %        281        281                      
                                                                       0.03    0.06    0.05    0.58
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.33    8.28    0.58   12.31   100.0 %        281        281                      
                                                                       1.33    8.28    0.58   12.31
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    2.14    7.81    0.47   18.20   100.0 %        539        539                      
                                                                       2.14    7.81    0.47   18.20
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.10   100.0 %        245        245                      
                                                                       0.00    0.05    0.05    0.10
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.00    0.58    0.58    0.58   100.0 %          1          1                      
                                                                       0.00    0.58    0.58    0.58
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.26    0.29    0.11    0.48   100.0 %          2          2                      
                                                                       0.26    0.29    0.11    0.48
     secondaryMirror.command.setLocalOffsets. . . . . . . . . . . .    5.29    8.95    1.02   18.31   100.0 %         18         18                      
                                                                       5.29    8.95    1.02   18.31
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.03    0.06    0.05    0.61   100.0 %        281        281                      
                                                                       0.03    0.06    0.05    0.61
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.00    0.12    0.12    0.12   100.0 %          1          1                      
                                                                       0.00    0.12    0.12    0.12
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.24    0.24    0.07    0.41   100.0 %          2          2                      
                                                                       0.24    0.24    0.07    0.41

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                301           

PSF Events of Interest

   1  STARTUP   PSF        startup                                                       Tue May 12 20:21:40.287 2009  to  Tue May 12 20:21:40.287 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

   2  FAILED    PSF        command.setNewInstrument                                      Tue May 12 18:56:30.074 2009  to  Tue May 12 18:56:30.577 2009   (  0.50) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

   3  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May 12 18:56:30.127 2009  to  Tue May 12 18:56:30.227 2009   (  0.10) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   4  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:27:59.864 2009  to  Tue May 12 20:27:59.864 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

   5  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:28:00.120 2009  to  Tue May 12 20:28:00.120 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:28:10.698 2009  to  Tue May 12 20:28:10.698 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:29:47.909 2009  to  Tue May 12 20:29:47.909 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:30:30.069 2009  to  Tue May 12 20:30:30.069 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:30:30.324 2009  to  Tue May 12 20:30:30.324 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 12 21:23:08.056 2009  to  Tue May 12 21:23:08.279 2009   (  0.22) secs
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  11  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 12 21:25:57.604 2009  to  Tue May 12 21:25:57.853 2009   (  0.25) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  12  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Tue May 12 21:25:57.549 2009  to  Tue May 12 21:25:57.909 2009   (  0.36) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  13  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:55.769 2009  to  Tue May 12 23:18:55.769 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0371506e-03 1.3239980e-03 9.3084574e-04 2.7816772e-02 2.0489502e-01 -2.1824062e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:56.024 2009  to  Tue May 12 23:18:56.024 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0371506e-03 1.3239980e-03 9.3084574e-04 2.7816772e-02 2.0489502e-01 -2.1824062e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:57.291 2009  to  Tue May 12 23:18:57.291 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.3780187e-04 1.3831258e-03 1.5991926e-04 6.7367554e-03 1.5177155e-01 -3.1401515e-03

  16  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:57.545 2009  to  Tue May 12 23:18:57.545 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.3780187e-04 1.3831258e-03 1.5991926e-04 6.7367554e-03 1.5177155e-01 -3.1401515e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:23.911 2009  to  Tue May 12 23:19:23.911 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:24.167 2009  to  Tue May 12 23:19:24.167 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:24.423 2009  to  Tue May 12 23:19:24.423 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:44:34.953 2009  to  Tue May 12 23:44:34.953 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.3650358e-03 7.9464912e-04 6.4736605e-04 2.7740479e-02 1.6037750e-01 -9.9938512e-03

  21  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:44:50.794 2009  to  Tue May 12 23:44:50.794 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.9080801e-04 1.4425516e-03 7.9226494e-04 1.9989014e-02 1.5053368e-01 -4.3238044e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:48:19.114 2009  to  Tue May 12 23:48:19.114 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0920912e-03 1.7356873e-04 6.4980984e-04 -1.8764496e-02 1.6863251e-01 -6.4556889e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:49:47.811 2009  to  Tue May 12 23:49:47.811 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.0705163e-04 1.2641549e-03 3.6305189e-04 3.5400391e-03 1.6621208e-01 -1.9912422e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:49:48.066 2009  to  Tue May 12 23:49:48.066 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.0705163e-04 1.2641549e-03 3.6305189e-04 3.5400391e-03 1.6621208e-01 -1.9912422e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.188 2009  to  Wed May 13 00:13:18.188 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

  26  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.443 2009  to  Wed May 13 00:13:18.443 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

  27  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.698 2009  to  Wed May 13 00:13:18.698 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:24:03.598 2009  to  Wed May 13 00:24:03.598 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4450164e-04 5.4478645e-04 7.8690052e-04 -7.2364807e-03 1.7189407e-01 -2.1437503e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:24:03.852 2009  to  Wed May 13 00:24:03.852 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4450164e-04 5.4478645e-04 7.8690052e-04 -7.2364807e-03 1.7189407e-01 -2.1437503e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:43:49.340 2009  to  Wed May 13 00:43:49.340 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.4700842e-05 1.7277598e-03 1.0418892e-04 -3.5039902e-02 1.5536308e-01 4.1458309e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:43:49.595 2009  to  Wed May 13 00:43:49.595 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.4700842e-05 1.7277598e-03 1.0418892e-04 -3.5039902e-02 1.5536308e-01 4.1458309e-03
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  STARTUP   LSS        startup                                                       Tue May 12 18:49:30.070 2009  to  Tue May 12 18:49:30.070 2009   (  0.00) secs
                     The LSS was started.

   2  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 18:51:14.098 2009  to  Tue May 12 18:51:14.098 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   3  FAILED    ECS        weatherStation.noWeatherData                                  Tue May 12 18:51:24.619 2009  to  Tue May 12 18:51:24.619 2009   (  0.00) secs
                     Stale or no data being received from SMT.

   4  FAILED    ECS        plc.read.failed                                               Tue May 12 18:54:19.868 2009  to  Tue May 12 18:54:19.868 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

   5  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 18:57:28.856 2009  to  Tue May 12 18:57:28.856 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0577999e+01, because Not Connected to PLC

   6  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 18:57:28.915 2009  to  Tue May 12 18:57:28.915 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.8999996e-01

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 18:57:39.059 2009  to  Tue May 12 18:57:39.059 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    PMC        actuator.telemetryError                                       Tue May 12 18:58:46.645 2009  to  Tue May 12 18:58:46.645 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   9  STARTUP   PMC        startup                                                       Tue May 12 18:59:16.292 2009  to  Tue May 12 18:59:16.292 2009   (  0.00) secs
                     left PMC subsystem started, version 4.9

  10  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:00:37.844 2009  to  Tue May 12 19:00:37.844 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component SM_DELAY, value 2, because Not Connected to PLC

  11  FAILED    ECS        plc.read.failed                                               Tue May 12 19:03:46.832 2009  to  Tue May 12 19:03:46.832 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  12  STARTUP   OSS        startup                                                       Tue May 12 19:03:55.576 2009  to  Tue May 12 19:03:55.576 2009   (  0.00) secs
                     The oss was started.

  13  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:06:55.820 2009  to  Tue May 12 19:06:55.820 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0671600e+01, because Not Connected to PLC

  14  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:06:55.882 2009  to  Tue May 12 19:06:55.882 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.3799992e-01

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:07:05.966 2009  to  Tue May 12 19:07:05.966 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  STARTUP   GCS        startup                                                       Tue May 12 19:09:07.500 2009  to  Tue May 12 19:09:07.500 2009   (  0.00) secs
                     left GCS subsystem started

  17  FAILED    ECS        plc.read.failed                                               Tue May 12 19:10:04.809 2009  to  Tue May 12 19:10:04.809 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  18  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:13:13.797 2009  to  Tue May 12 19:13:13.797 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0689600e+01, because Not Connected to PLC

  19  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:13:13.873 2009  to  Tue May 12 19:13:13.873 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.2799969e-01

  20  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:13:23.962 2009  to  Tue May 12 19:13:23.962 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  21  FAILED    ECS        plc.read.failed                                               Tue May 12 19:16:22.786 2009  to  Tue May 12 19:16:22.786 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  22  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:19:31.774 2009  to  Tue May 12 19:19:31.774 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0712999e+01, because Not Connected to PLC

  23  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:19:31.839 2009  to  Tue May 12 19:19:31.839 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.1500015e-01

  24  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:19:41.934 2009  to  Tue May 12 19:19:41.934 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  25  FAILED    ECS        plc.read.failed                                               Tue May 12 19:22:40.763 2009  to  Tue May 12 19:22:40.763 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  26  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:25:49.812 2009  to  Tue May 12 19:25:49.812 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -7.0600033e-01

  27  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:25:49.751 2009  to  Tue May 12 19:25:49.751 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0729198e+01, because Not Connected to PLC

  28  FAILED    ECS        plc.read.failed                                               Tue May 12 19:28:58.740 2009  to  Tue May 12 19:28:58.740 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  29  FAILED    ECS        plc.read.failed                                               Tue May 12 19:32:07.896 2009  to  Tue May 12 19:32:07.896 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  30  FAILED    PMC        actuator.telemetryError                                       Tue May 12 19:33:56.512 2009  to  Tue May 12 19:33:56.512 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  31  FAILED    ECS        plc.read.failed                                               Tue May 12 19:35:17.051 2009  to  Tue May 12 19:35:17.051 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  32  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:42:43.595 2009  to  Tue May 12 19:42:43.595 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  33  FAILED    ECS        weatherStation.noWeatherData                                  Tue May 12 19:42:54.121 2009  to  Tue May 12 19:42:54.121 2009   (  0.00) secs
                     Stale or no data being received from SMT.

  34  FAILED    ECS        plc.read.failed                                               Tue May 12 19:45:52.320 2009  to  Tue May 12 19:45:52.320 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  35  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:49:01.379 2009  to  Tue May 12 19:49:01.379 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.9600010e-01

  36  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:49:01.321 2009  to  Tue May 12 19:49:01.321 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0747200e+01, because Not Connected to PLC

  37  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:49:11.459 2009  to  Tue May 12 19:49:11.459 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  38  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:52:10.322 2009  to  Tue May 12 19:52:10.322 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component SM_DELAY, value 2, because Not Connected to PLC

  39  FAILED    ECS        plc.read.failed                                               Tue May 12 19:55:19.324 2009  to  Tue May 12 19:55:19.324 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  40  STARTUP   PCS        startup                                                       Tue May 12 19:57:02.799 2009  to  Tue May 12 19:57:02.799 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

  41  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 19:58:28.325 2009  to  Tue May 12 19:58:28.325 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0808401e+01, because Not Connected to PLC

  42  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 19:58:28.381 2009  to  Tue May 12 19:58:28.381 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.6199970e-01

  43  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 19:58:38.457 2009  to  Tue May 12 19:58:38.457 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  44  FAILED    ECS        plc.read.failed                                               Tue May 12 20:01:37.327 2009  to  Tue May 12 20:01:37.327 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  45  STARTUP   IIF        startup                                                       Tue May 12 20:03:24.364 2009  to  Tue May 12 20:03:24.364 2009   (  0.00) secs
                     IIF subsystem started

  46  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 20:04:20.192 2009  to  Tue May 12 20:04:20.204 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  47  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 20:04:20.346 2009  to  Tue May 12 20:04:20.346 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  48  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:04:46.328 2009  to  Tue May 12 20:04:46.328 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0826399e+01, because Not Connected to PLC

  49  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:04:46.391 2009  to  Tue May 12 20:04:46.391 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.5200043e-01

  50  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 20:04:56.489 2009  to  Tue May 12 20:04:56.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  51  FAILED    ECS        plc.read.failed                                               Tue May 12 20:07:55.330 2009  to  Tue May 12 20:07:55.330 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  52  FAILED    PCS        telescope.command.startTracking                               Tue May 12 20:08:08.835 2009  to  Tue May 12 20:08:09.655 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

  53  FAILED    PCS        telescope.command.stopTracking                                Tue May 12 20:08:18.787 2009  to  Tue May 12 20:08:18.932 2009   (  0.15) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  54  FAILED    PCS        telescope.command.stopTracking                                Tue May 12 20:08:34.839 2009  to  Tue May 12 20:08:35.022 2009   (  0.18) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  55  SHUTDOWN  PCS        shutdown                                                      Tue May 12 20:08:59.501 2009  to  Tue May 12 20:08:59.501 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.35

  56  STARTUP   PCS        startup                                                       Tue May 12 20:09:10.642 2009  to  Tue May 12 20:09:10.642 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.35

  57  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:11:04.332 2009  to  Tue May 12 20:11:04.332 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0857000e+01, because Not Connected to PLC

  58  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:11:04.413 2009  to  Tue May 12 20:11:04.413 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.3500023e-01

  59  FAILED    ECS        instrumentCooling.badPMCData                                  Tue May 12 20:11:14.489 2009  to  Tue May 12 20:11:14.489 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  60  STARTUP   GCS        startup                                                       Tue May 12 20:13:24.747 2009  to  Tue May 12 20:13:24.747 2009   (  0.00) secs
                     left GCS subsystem started

  61  FAILED    ECS        plc.read.failed                                               Tue May 12 20:14:13.334 2009  to  Tue May 12 20:14:13.334 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  62  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:17:22.335 2009  to  Tue May 12 20:17:22.335 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0875000e+01, because Not Connected to PLC

  63  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:17:22.401 2009  to  Tue May 12 20:17:22.401 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.2500000e-01

  64  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.400 2009  to  Tue May 12 20:18:11.400 2009   (  0.00) secs
                     left PMC PMC closing network connection

  65  SHUTDOWN  PMC        shutdown                                                      Tue May 12 20:18:11.349 2009  to  Tue May 12 20:18:11.349 2009   (  0.00) secs
                     left PMC subsystem shut down

  66  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.503 2009  to  Tue May 12 20:18:11.503 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

  67  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.554 2009  to  Tue May 12 20:18:11.554 2009   (  0.00) secs
                     left PMC Async closing network connection

  68  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.656 2009  to  Tue May 12 20:18:11.656 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  69  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.757 2009  to  Tue May 12 20:18:11.757 2009   (  0.00) secs
                     left PMC Mount closing network connection

  70  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.859 2009  to  Tue May 12 20:18:11.859 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  71  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:11.961 2009  to  Tue May 12 20:18:11.961 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  72  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.063 2009  to  Tue May 12 20:18:12.063 2009   (  0.00) secs
                     left PMC Motor closing network connection

  73  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.165 2009  to  Tue May 12 20:18:12.165 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  74  FAILED    PMC        VxInterface.close                                             Tue May 12 20:18:12.217 2009  to  Tue May 12 20:18:12.217 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  75  FAILED    PMC        actuator.telemetryError                                       Tue May 12 20:18:23.053 2009  to  Tue May 12 20:18:23.053 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  76  STARTUP   PMC        startup                                                       Tue May 12 20:18:25.916 2009  to  Tue May 12 20:18:25.916 2009   (  0.00) secs
                     left PMC subsystem started, version 4.9

  77  FAILED    PMC        actuator.telemetryError                                       Tue May 12 20:18:31.109 2009  to  Tue May 12 20:18:31.109 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  78  STARTUP   ENV        startup                                                       Tue May 12 20:19:42.910 2009  to  Tue May 12 20:19:42.910 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

  79  FAILED    ECS        plc.read.failed                                               Tue May 12 20:20:31.337 2009  to  Tue May 12 20:20:31.337 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  80  SHUTDOWN  ENV        command.shutdown                                              Tue May 12 20:20:37.111 2009  to  Tue May 12 20:20:37.111 2009   (  0.00) secs
                     ENV shutdown command started

  81  SHUTDOWN  ENV        command.shutdown                                              Tue May 12 20:20:37.358 2009  to  Tue May 12 20:20:37.358 2009   (  0.00) secs
                     Env shutdown command complete

  82  SHUTDOWN  ENV        shutdown                                                      Tue May 12 20:20:37.409 2009  to  Tue May 12 20:20:37.409 2009   (  0.00) secs
                     ENV subsystem shut down

  83  STARTUP   PSF        startup                                                       Tue May 12 20:21:40.287 2009  to  Tue May 12 20:21:40.287 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

  84  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:23:40.339 2009  to  Tue May 12 20:23:40.339 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  85  STARTUP   AOS        startup                                                       Tue May 12 20:24:21.499 2009  to  Tue May 12 20:24:21.499 2009   (  0.00) secs
                     AOS subsystem started - AOS Version .

  86  SHUTDOWN  AOS        command.shutdown                                              Tue May 12 20:24:41.922 2009  to  Tue May 12 20:24:41.922 2009   (  0.00) secs
                    

  87  SHUTDOWN  AOS        shutdown                                                      Tue May 12 20:24:41.973 2009  to  Tue May 12 20:24:41.973 2009   (  0.00) secs
                     AOS subsystem shut down - AOS Version .

  88  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:26:49.340 2009  to  Tue May 12 20:26:49.340 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  89  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:29:58.340 2009  to  Tue May 12 20:29:58.340 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_LEFT, value 4.8496403e+01, because Not Connected to PLC

  90  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue May 12 20:29:58.393 2009  to  Tue May 12 20:29:58.393 2009   (  0.00) secs
                     Instrument cooling command set temperature set pt failed:temp 9.1646671e+00

  91  FAILED    ECS        plc.read.failed                                               Tue May 12 20:33:07.341 2009  to  Tue May 12 20:33:07.341 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  92  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:36:16.342 2009  to  Tue May 12 20:36:16.342 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  93  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:39:25.343 2009  to  Tue May 12 20:39:25.343 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  94  STARTUP   GCS        startup                                                       Tue May 12 20:41:43.126 2009  to  Tue May 12 20:41:43.126 2009   (  0.00) secs
                     left GCS subsystem started

  95  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue May 12 20:42:34.397 2009  to  Tue May 12 20:42:34.397 2009   (  0.00) secs
                     Instrument cooling command set temperature set pt failed:temp 9.3906670e+00

  96  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:42:34.344 2009  to  Tue May 12 20:42:34.344 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_RIGHT, value 4.8903202e+01, because Not Connected to PLC

  97  FAILED    ECS        plc.read.failed                                               Tue May 12 20:45:43.345 2009  to  Tue May 12 20:45:43.345 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

  98  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:48:52.346 2009  to  Tue May 12 20:48:52.346 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

  99  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:52:01.347 2009  to  Tue May 12 20:52:01.347 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

 100  STARTUP   GCS        startup                                                       Tue May 12 20:52:23.694 2009  to  Tue May 12 20:52:23.694 2009   (  0.00) secs
                     left GCS subsystem started

 101  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Tue May 12 20:55:10.403 2009  to  Tue May 12 20:55:10.403 2009   (  0.00) secs
                     Hydraulic bearing command set temperature set point failed:temp -6.1299992e-01

 102  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 20:55:10.347 2009  to  Tue May 12 20:55:10.347 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 3.0896601e+01, because Not Connected to PLC

 103  FAILED    ECS        plc.read.failed                                               Tue May 12 20:58:19.348 2009  to  Tue May 12 20:58:19.348 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

 104  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 21:01:28.349 2009  to  Tue May 12 21:01:28.349 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

 105  FAILED    ECS        plc.writeHS.failed                                            Tue May 12 21:04:37.350 2009  to  Tue May 12 21:04:37.350 2009   (  0.00) secs
                     ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT_LEFT, value 4.6572800e+01, because Not Connected to PLC

 106  STARTUP   GCS        startup                                                       Tue May 12 21:06:53.257 2009  to  Tue May 12 21:06:53.257 2009   (  0.00) secs
                     left GCS subsystem started

 107  FAILED    GCS        command.setAGW                                                Tue May 12 21:07:02.893 2009  to  Tue May 12 21:07:02.960 2009   (  0.07) secs
                     COULD NOT change active AGW configuration to -u

 108  FAILED    ECS        plc.read.failed                                               Tue May 12 21:07:46.350 2009  to  Tue May 12 21:07:46.350 2009   (  0.00) secs
                     ECS PLC read failed because Not Connected to PLC

 109  FAILED    GCS        command.setAGW                                                Tue May 12 18:40:19.841 2009  to  Tue May 12 18:40:49.865 2009   ( 30.02) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

 110  FAILED    GCS        command.setAGW                                                Tue May 12 18:41:27.924 2009  to  Tue May 12 18:42:03.883 2009   ( 35.96) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

 111  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 12 18:47:38.745 2009  to  Tue May 12 18:47:38.745 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 112  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May 12 18:47:38.766 2009  to  Tue May 12 18:47:38.766 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 113  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue May 12 18:47:38.862 2009  to  Tue May 12 18:47:38.862 2009   (  0.00) secs
                     drive cabinet has turned on.

 114  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.871 2009  to  Tue May 12 18:47:39.871 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 115  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.871 2009  to  Tue May 12 18:47:39.871 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 116  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.872 2009  to  Tue May 12 18:47:39.872 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 117  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.872 2009  to  Tue May 12 18:47:39.872 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 118  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.873 2009  to  Tue May 12 18:47:39.873 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 119  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.873 2009  to  Tue May 12 18:47:39.873 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 120  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.874 2009  to  Tue May 12 18:47:39.874 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 121  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue May 12 18:47:39.874 2009  to  Tue May 12 18:47:39.874 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 122  SHUTDOWN  GCS        command.shutdown                                              Tue May 12 18:53:41.436 2009  to  Tue May 12 18:53:41.436 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 123  SHUTDOWN  GCS        command.shutdown                                              Tue May 12 18:53:43.183 2009  to  Tue May 12 18:53:43.183 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 124  STARTUP   GCS        startup                                                       Tue May 12 18:53:49.228 2009  to  Tue May 12 18:53:49.228 2009   (  0.00) secs
                     left GCS subsystem started

 125  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May 12 18:56:29.409 2009  to  Tue May 12 18:56:30.791 2009   (  1.38) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

 126  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 18:56:29.601 2009  to  Tue May 12 18:56:29.601 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 127  SEQERROR  PCS        telescope.command.stopTracking                                Tue May 12 18:56:29.711 2009  to  Tue May 12 18:56:29.711 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 128  FAILED    PSF        command.setNewInstrument                                      Tue May 12 18:56:30.074 2009  to  Tue May 12 18:56:30.577 2009   (  0.50) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

 129  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May 12 18:56:30.127 2009  to  Tue May 12 18:56:30.227 2009   (  0.10) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 130  STARTUP   GCS        startup                                                       Tue May 12 18:56:42.382 2009  to  Tue May 12 18:56:42.382 2009   (  0.00) secs
                     left GCS subsystem started

 131  STARTUP   GCS        startup                                                       Tue May 12 19:05:51.999 2009  to  Tue May 12 19:05:51.999 2009   (  0.00) secs
                     left GCS subsystem started

 132  STARTUP   GCS        startup                                                       Tue May 12 19:26:59.151 2009  to  Tue May 12 19:26:59.151 2009   (  0.00) secs
                     left GCS subsystem started

 133  FAILED    GCS        command.getFullWFImage                                        Tue May 12 19:48:24.143 2009  to  Tue May 12 19:48:27.399 2009   (  3.26) secs
                     AzCam server timed out waiting for full CCD readout

 134  FAILED    GCS        command.getFullWFImage                                        Tue May 12 19:48:46.031 2009  to  Tue May 12 19:48:49.281 2009   (  3.25) secs
                     AzCam server timed out waiting for full CCD readout

 135  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:54:31.568 2009  to  Tue May 12 19:54:33.422 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

 136  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:54:49.846 2009  to  Tue May 12 19:54:51.699 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

 137  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:16.714 2009  to  Tue May 12 19:55:18.571 2009   (  1.86) secs
                     AzCam server timed out waiting for full CCD readout

 138  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:25.491 2009  to  Tue May 12 19:55:27.596 2009   (  2.11) secs
                     AzCam server timed out waiting for full CCD readout

 139  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:55:44.130 2009  to  Tue May 12 19:55:46.223 2009   (  2.09) secs
                     AzCam server timed out waiting for full CCD readout

 140  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:56:28.608 2009  to  Tue May 12 19:56:30.948 2009   (  2.34) secs
                     AzCam server timed out waiting for full CCD readout

 141  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:56:44.348 2009  to  Tue May 12 19:56:46.932 2009   (  2.58) secs
                     AzCam server timed out waiting for full CCD readout

 142  FAILED    GCS        command.getFullGuideImage                                     Tue May 12 19:57:32.492 2009  to  Tue May 12 19:57:35.311 2009   (  2.82) secs
                     AzCam server timed out waiting for full CCD readout

 143  FAILED    IIF        command.preset.(ACQUIRE)                                      Tue May 12 20:06:41.000 2009  to  Tue May 12 20:06:44.079 2009   (  3.08) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGw command status: AGW2: Axes had not been homed, yet
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGw command status: AGW2: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -3.0397e-08, 0.177361, 30.9876 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 144  FAILED    GCS        command.setGuidestarList                                      Tue May 12 20:06:42.535 2009  to  Tue May 12 20:06:43.756 2009   (  1.22) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 145  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 20:06:42.891 2009  to  Tue May 12 20:06:43.701 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -3.0397e-08, 0.177361, focus: 30.9876 :AGW2: Axes had not been homed, yet

 146  FAILED    PMC        VxInterface.close                                             Tue May 12 20:20:12.315 2009  to  Tue May 12 20:20:12.315 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 147  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:20:12.263 2009  to  Tue May 12 20:20:12.263 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 148  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:21:33.006 2009  to  Tue May 12 20:21:33.006 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 149  FAILED    PMC        VxInterface.close                                             Tue May 12 20:21:33.059 2009  to  Tue May 12 20:21:33.059 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 150  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:27:59.864 2009  to  Tue May 12 20:27:59.864 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 151  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:28:00.120 2009  to  Tue May 12 20:28:00.120 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 152  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:28:10.698 2009  to  Tue May 12 20:28:10.698 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 153  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:29:47.909 2009  to  Tue May 12 20:29:47.909 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 154  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:30:30.069 2009  to  Tue May 12 20:30:30.069 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 155  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 20:30:30.324 2009  to  Tue May 12 20:30:30.324 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.1575222e-03 -2.0980835e-05 -5.7339668e-04 -4.9922943e-02 -1.5407372e-01 4.3534279e-02

 156  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 20:38:34.775 2009  to  Tue May 12 20:38:34.775 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 157  FAILED    PMC        VxInterface.close                                             Tue May 12 20:38:34.827 2009  to  Tue May 12 20:38:34.827 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 158  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:17:36.170 2009  to  Tue May 12 21:17:38.892 2009   (  2.72) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -195.818, 86.41, 11.0561 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 159  FAILED    GCS        command.setGuidestarList                                      Tue May 12 21:17:37.667 2009  to  Tue May 12 21:17:38.567 2009   (  0.90) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 160  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 21:17:37.957 2009  to  Tue May 12 21:17:38.512 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -195.818, 86.41, focus: 11.0561 :AGW2: Requested position is Out of Range

 161  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:22:45.093 2009  to  Tue May 12 21:23:11.546 2009   ( 26.45) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 162  FAILED    PMC        mirror.panic                                                  Tue May 12 21:22:59.627 2009  to  Tue May 12 21:22:59.627 2009   (  0.00) secs
                     left PMC ** PANIC: Outer loop stalled

 163  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 12 21:23:08.056 2009  to  Tue May 12 21:23:08.279 2009   (  0.22) secs
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 164  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 12 21:23:08.164 2009  to  Tue May 12 21:23:08.217 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 165  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue May 12 21:25:57.604 2009  to  Tue May 12 21:25:57.853 2009   (  0.25) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 166  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Tue May 12 21:25:57.549 2009  to  Tue May 12 21:25:57.909 2009   (  0.36) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

 167  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue May 12 21:25:57.685 2009  to  Tue May 12 21:25:57.787 2009   (  0.10) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 168  FAILED    PMC        mirror.command.raise.auto                                     Tue May 12 21:27:07.988 2009  to  Tue May 12 21:28:50.389 2009   (102.40) secs
                     left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

 169  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 21:53:59.641 2009  to  Tue May 12 21:54:05.977 2009   (  6.34) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -193.591, 74.5469, 12.4031 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 170  FAILED    GCS        command.setGuidestarList                                      Tue May 12 21:54:04.752 2009  to  Tue May 12 21:54:05.654 2009   (  0.90) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 171  FAILED    GCS        interface.agw.setProbePosition                                Tue May 12 21:54:05.043 2009  to  Tue May 12 21:54:05.600 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -193.591, 74.5469, focus: 12.4031 :AGW2: Requested position is Out of Range

 172  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:33:41.819 2009  to  Tue May 12 22:34:37.766 2009   ( 55.95) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 173  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:34:28.036 2009  to  Tue May 12 22:34:37.593 2009   (  9.56) secs
                     couldn''t find a star in any GS location.

 174  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:35:51.082 2009  to  Tue May 12 22:36:26.901 2009   ( 35.82) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 175  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:36:16.612 2009  to  Tue May 12 22:36:26.731 2009   ( 10.12) secs
                     couldn''t find a star in any GS location.

 176  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:37:39.712 2009  to  Tue May 12 22:38:14.312 2009   ( 34.60) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 177  FAILED    PMC        VxInterface.close                                             Tue May 12 22:37:56.024 2009  to  Tue May 12 22:37:56.024 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 178  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 22:37:55.973 2009  to  Tue May 12 22:37:55.973 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 179  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:38:04.241 2009  to  Tue May 12 22:38:14.141 2009   (  9.90) secs
                     couldn''t find a star in any GS location.

 180  FAILED    IIF        command.preset.(ACTIVE)                                       Tue May 12 22:44:22.208 2009  to  Tue May 12 22:45:36.992 2009   ( 74.78) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 181  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue May 12 22:45:27.075 2009  to  Tue May 12 22:45:36.821 2009   (  9.75) secs
                     couldn''t find a star in any GS location.

 182  FAILED    PMC        VxInterface.close                                             Tue May 12 23:09:22.997 2009  to  Tue May 12 23:09:22.997 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 183  FAILED    PMC        VxInterface.lengthError                                       Tue May 12 23:09:22.944 2009  to  Tue May 12 23:09:22.944 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 184  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:55.769 2009  to  Tue May 12 23:18:55.769 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0371506e-03 1.3239980e-03 9.3084574e-04 2.7816772e-02 2.0489502e-01 -2.1824062e-02

 185  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:56.024 2009  to  Tue May 12 23:18:56.024 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0371506e-03 1.3239980e-03 9.3084574e-04 2.7816772e-02 2.0489502e-01 -2.1824062e-02

 186  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:57.291 2009  to  Tue May 12 23:18:57.291 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.3780187e-04 1.3831258e-03 1.5991926e-04 6.7367554e-03 1.5177155e-01 -3.1401515e-03

 187  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:18:57.545 2009  to  Tue May 12 23:18:57.545 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.3780187e-04 1.3831258e-03 1.5991926e-04 6.7367554e-03 1.5177155e-01 -3.1401515e-03

 188  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:23.911 2009  to  Tue May 12 23:19:23.911 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

 189  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:24.167 2009  to  Tue May 12 23:19:24.167 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

 190  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:19:24.423 2009  to  Tue May 12 23:19:24.423 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0186359e-03 1.3936758e-03 3.4433603e-04 5.1521301e-02 1.6191864e-01 -1.3586223e-02

 191  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:44:34.953 2009  to  Tue May 12 23:44:34.953 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.3650358e-03 7.9464912e-04 6.4736605e-04 2.7740479e-02 1.6037750e-01 -9.9938512e-03

 192  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:44:50.794 2009  to  Tue May 12 23:44:50.794 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.9080801e-04 1.4425516e-03 7.9226494e-04 1.9989014e-02 1.5053368e-01 -4.3238044e-02

 193  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:48:19.114 2009  to  Tue May 12 23:48:19.114 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.0920912e-03 1.7356873e-04 6.4980984e-04 -1.8764496e-02 1.6863251e-01 -6.4556889e-02

 194  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:49:47.811 2009  to  Tue May 12 23:49:47.811 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.0705163e-04 1.2641549e-03 3.6305189e-04 3.5400391e-03 1.6621208e-01 -1.9912422e-02

 195  FAILED    PSF        primaryMirror.positionError                                   Tue May 12 23:49:48.066 2009  to  Tue May 12 23:49:48.066 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.0705163e-04 1.2641549e-03 3.6305189e-04 3.5400391e-03 1.6621208e-01 -1.9912422e-02

 196  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:04:05.183 2009  to  Wed May 13 00:04:05.183 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 197  FAILED    PMC        VxInterface.close                                             Wed May 13 00:04:05.236 2009  to  Wed May 13 00:04:05.236 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 198  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.188 2009  to  Wed May 13 00:13:18.188 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

 199  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.443 2009  to  Wed May 13 00:13:18.443 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

 200  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:13:18.698 2009  to  Wed May 13 00:13:18.698 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.5706501e-04 -3.1633377e-03 -2.4676323e-05 4.0702820e-03 -9.6727371e-02 8.6682998e-03

 201  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:20:03.834 2009  to  Wed May 13 00:20:03.834 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 202  FAILED    PMC        VxInterface.close                                             Wed May 13 00:20:03.886 2009  to  Wed May 13 00:20:03.886 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 203  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:24:03.598 2009  to  Wed May 13 00:24:03.598 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4450164e-04 5.4478645e-04 7.8690052e-04 -7.2364807e-03 1.7189407e-01 -2.1437503e-02

 204  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:24:03.852 2009  to  Wed May 13 00:24:03.852 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4450164e-04 5.4478645e-04 7.8690052e-04 -7.2364807e-03 1.7189407e-01 -2.1437503e-02

 205  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:43:49.340 2009  to  Wed May 13 00:43:49.340 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.4700842e-05 1.7277598e-03 1.0418892e-04 -3.5039902e-02 1.5536308e-01 4.1458309e-03

 206  FAILED    PSF        primaryMirror.positionError                                   Wed May 13 00:43:49.595 2009  to  Wed May 13 00:43:49.595 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.4700842e-05 1.7277598e-03 1.0418892e-04 -3.5039902e-02 1.5536308e-01 4.1458309e-03

 207  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 00:51:21.049 2009  to  Wed May 13 00:51:21.049 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 208  FAILED    PMC        VxInterface.close                                             Wed May 13 00:51:21.103 2009  to  Wed May 13 00:51:21.103 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 209  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:14:41.148 2009  to  Wed May 13 01:14:53.515 2009   ( 12.37) secs
                     request to AzCam server for a full CCD readout failed

 210  FAILED    GCS        command.autoAcquireGuidestar                                  Wed May 13 01:18:35.252 2009  to  Wed May 13 01:19:15.835 2009   ( 40.58) secs
                     guiding was not stable within 6 cycles

 211  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:23:34.981 2009  to  Wed May 13 01:23:57.349 2009   ( 22.37) secs
                     request to AzCam server for a full CCD readout failed

 212  FAILED    GCS        command.getFullGuideImage                                     Wed May 13 01:30:48.982 2009  to  Wed May 13 01:31:11.349 2009   ( 22.37) secs
                     request to AzCam server for a full CCD readout failed

 213  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 01:50:38.506 2009  to  Wed May 13 01:50:38.506 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 214  FAILED    PMC        VxInterface.close                                             Wed May 13 01:50:38.558 2009  to  Wed May 13 01:50:38.558 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 215  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 02:06:46.635 2009  to  Wed May 13 02:06:46.635 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 216  FAILED    PMC        VxInterface.close                                             Wed May 13 02:06:46.688 2009  to  Wed May 13 02:06:46.688 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 217  FAILED    PMC        mirror.panic                                                  Wed May 13 03:14:56.494 2009  to  Wed May 13 03:14:56.494 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

 218  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:56.598 2009  to  Wed May 13 03:14:56.598 2009   (  0.00) secs
                     right PMC Actuator 124 get force read error: -3

 219  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:58.519 2009  to  Wed May 13 03:14:58.519 2009   (  0.00) secs
                     right PMC Actuator 242 get force read error: -3

 220  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:14:58.467 2009  to  Wed May 13 03:14:58.467 2009   (  0.00) secs
                     right PMC Actuator 440 set force bad return: 163 instead of 19

 221  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:14:58.826 2009  to  Wed May 13 03:14:58.826 2009   (  0.00) secs
                     right PMC Actuator 114 set force read error: -3

 222  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:14:59.130 2009  to  Wed May 13 03:14:59.130 2009   (  0.00) secs
                     right PMC Actuator 103 set force bad return: 170 instead of 1

 223  FAILED    PMC        actuator.getForce.readError                                   Wed May 13 03:14:59.182 2009  to  Wed May 13 03:14:59.182 2009   (  0.00) secs
                     right PMC Actuator 233 get force read error: -3

 224  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.234 2009  to  Wed May 13 03:14:59.234 2009   (  0.00) secs
                     right PMC Actuator 113 has been reset

 225  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.286 2009  to  Wed May 13 03:14:59.286 2009   (  0.00) secs
                     right PMC Actuator 109 has been reset

 226  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.338 2009  to  Wed May 13 03:14:59.338 2009   (  0.00) secs
                     right PMC Actuator 127 has been reset

 227  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.390 2009  to  Wed May 13 03:14:59.390 2009   (  0.00) secs
                     right PMC Actuator 117 has been reset

 228  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.442 2009  to  Wed May 13 03:14:59.442 2009   (  0.00) secs
                     right PMC Actuator 120 has been reset

 229  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.494 2009  to  Wed May 13 03:14:59.494 2009   (  0.00) secs
                     right PMC Actuator 134 has been reset

 230  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.546 2009  to  Wed May 13 03:14:59.546 2009   (  0.00) secs
                     right PMC Actuator 125 has been reset

 231  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.598 2009  to  Wed May 13 03:14:59.598 2009   (  0.00) secs
                     right PMC Actuator 131 has been reset

 232  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.650 2009  to  Wed May 13 03:14:59.650 2009   (  0.00) secs
                     right PMC Actuator 136 has been reset

 233  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.702 2009  to  Wed May 13 03:14:59.702 2009   (  0.00) secs
                     right PMC Actuator 129 has been reset

 234  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.754 2009  to  Wed May 13 03:14:59.754 2009   (  0.00) secs
                     right PMC Actuator 138 has been reset

 235  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.806 2009  to  Wed May 13 03:14:59.806 2009   (  0.00) secs
                     right PMC Actuator 143 has been reset

 236  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.858 2009  to  Wed May 13 03:14:59.858 2009   (  0.00) secs
                     right PMC Actuator 208 has been reset

 237  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:14:59.910 2009  to  Wed May 13 03:14:59.910 2009   (  0.00) secs
                     right PMC Actuator 121 set force read error: -3

 238  FAILED    PMC        actuator.reset                                                Wed May 13 03:14:59.962 2009  to  Wed May 13 03:14:59.962 2009   (  0.00) secs
                     right PMC Actuator 130 has been reset

 239  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.015 2009  to  Wed May 13 03:15:00.015 2009   (  0.00) secs
                     right PMC Actuator 124 has been reset

 240  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.067 2009  to  Wed May 13 03:15:00.067 2009   (  0.00) secs
                     right PMC Actuator 137 has been reset

 241  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.119 2009  to  Wed May 13 03:15:00.119 2009   (  0.00) secs
                     right PMC Actuator 126 has been reset

 242  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.171 2009  to  Wed May 13 03:15:00.171 2009   (  0.00) secs
                     right PMC Actuator 142 has been reset

 243  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.223 2009  to  Wed May 13 03:15:00.223 2009   (  0.00) secs
                     right PMC Actuator 212 has been reset

 244  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:15:00.528 2009  to  Wed May 13 03:15:00.528 2009   (  0.00) secs
                     right PMC Actuator 101 set force bad return: 160 instead of 1

 245  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:15:00.580 2009  to  Wed May 13 03:15:00.580 2009   (  0.00) secs
                     right PMC Actuator 133 set force read error: -3

 246  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.632 2009  to  Wed May 13 03:15:00.632 2009   (  0.00) secs
                     right PMC Actuator 333 has been reset

 247  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.684 2009  to  Wed May 13 03:15:00.684 2009   (  0.00) secs
                     right PMC Actuator 419 has been reset

 248  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.736 2009  to  Wed May 13 03:15:00.736 2009   (  0.00) secs
                     right PMC Actuator 407 has been reset

 249  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.788 2009  to  Wed May 13 03:15:00.788 2009   (  0.00) secs
                     right PMC Actuator 422 has been reset

 250  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.840 2009  to  Wed May 13 03:15:00.840 2009   (  0.00) secs
                     right PMC Actuator 413 has been reset

 251  FAILED    PMC        actuator.reset                                                Wed May 13 03:15:00.892 2009  to  Wed May 13 03:15:00.892 2009   (  0.00) secs
                     right PMC Actuator 427 has been reset

 252  FAILED    PMC        actuator.setForce.addressError                                Wed May 13 03:15:01.205 2009  to  Wed May 13 03:15:01.205 2009   (  0.00) secs
                     right PMC Actuator 209 set force bad return: 0 instead of 6

 253  FAILED    PMC        actuator.setForce.readError                                   Wed May 13 03:15:01.153 2009  to  Wed May 13 03:15:01.153 2009   (  0.00) secs
                     right PMC Actuator 140 set force read error: -3

 254  FAILED    PMC        command.recoverPanic                                          Wed May 13 03:15:04.580 2009  to  Wed May 13 03:15:04.633 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

 255  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 03:55:35.862 2009  to  Wed May 13 03:55:35.862 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 256  FAILED    PMC        VxInterface.close                                             Wed May 13 03:55:35.914 2009  to  Wed May 13 03:55:35.914 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 257  FAILED    PMC        VxInterface.close                                             Wed May 13 04:01:53.956 2009  to  Wed May 13 04:01:53.956 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 258  FAILED    PMC        VxInterface.lengthError                                       Wed May 13 04:01:53.904 2009  to  Wed May 13 04:01:53.904 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 259  FAILED    IIF        command.preset.(ACTIVE)                                       Wed May 13 04:29:35.146 2009  to  Wed May 13 04:29:46.828 2009   ( 11.68) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -173.46, 80.3089, 15.5558 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 260  FAILED    GCS        command.setGuidestarList                                      Wed May 13 04:29:37.946 2009  to  Wed May 13 04:29:46.499 2009   (  8.55) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 261  FAILED    GCS        interface.agw.setProbePosition                                Wed May 13 04:29:45.886 2009  to  Wed May 13 04:29:46.444 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -173.46, 80.3089, focus: 15.5558 :AGW2: Requested position is Out of Range

 262  FAILED    IIF        command.preset.(ACTIVE)                                       Wed May 13 04:31:01.695 2009  to  Wed May 13 04:31:03.986 2009   (  2.29) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -183.369, 71.9957, 14.4542 mm.
                     IIF Preset alert for left IRTC mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 263  FAILED    GCS        command.setGuidestarList                                      Wed May 13 04:31:03.007 2009  to  Wed May 13 04:31:03.659 2009   (  0.65) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 264  FAILED    GCS        interface.agw.setProbePosition                                Wed May 13 04:31:03.298 2009  to  Wed May 13 04:31:03.602 2009   (  0.30) secs
                     couldn''t move probe to position (SFP) -183.369, 71.9957, focus: 14.4542 :AGW2: Requested position is Out of Range

 265  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Wed May 13 05:03:47.961 2009  to  Wed May 13 05:03:47.961 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

**********************************************************
    Reporting period ending:   Wed May 13 05:51:49.487 2009
********************************************************************************************************