You are here: Foswiki>Software Web>TCSSWReportFile_090509 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 9 2009 to May 10 2009
 
    Reporting period beginning:   Sat May  9 18:37:00.721 2009
    Reporting period ending:      Sun May 10 05:53:58.335 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.45    0.77    0.43    1.42    50.0 %          4          2          2           
                                                                       0.20    0.57    0.43    0.71

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Sat May  9 20:11:15.658 2009  to  Sat May  9 20:11:17.077 2009   (  1.42) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Sat May  9 20:11:15.661 2009  to  Sat May  9 20:11:16.179 2009   (  0.52) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command. . . . . . . . . . . . . . . . . . . . . . . . . . . .                                    50.0 %                                              notAuthorized =     1
                                                                                                   
     command.move . . . . . . . . . . . . . . . . . . . . . . . . .    5.20    7.08    2.54   20.84   100.0 %         16         16                      
                                                                       5.20    7.08    2.54   20.84
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.64   15.23   13.48   18.36   100.0 %          9          9                      
                                                                       1.64   15.23   13.48   18.36
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.38    2.55    1.86    3.26   100.0 %          9          9                      
                                                                       0.38    2.55    1.86    3.26
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   72.14   94.26   16.94  172.32   100.0 %          6          6                      
                                                                      72.14   94.26   16.94  172.32
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   11.74   51.29   25.27   95.11    98.5 %         68         63          1          4
                                                                      11.83   51.34   25.27   95.11
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   18.00   49.92    5.31  108.65    95.6 %         45         33          2         10
                                                                      13.20   49.50   26.29   87.40
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    2.62    2.35    2.07   30.11   100.0 %        118        118                      
                                                                       2.62    2.35    2.07   30.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   18.15    7.85    1.05  119.27   100.0 %        118        118                      
                                                                      18.15    7.85    1.05  119.27
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    1.82    8.78    5.90   16.03   100.0 %         62         62                      
                                                                       1.82    8.78    5.90   16.03
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    0.00   15.84   15.84   15.84   100.0 %          1          1                      
                                                                       0.00   15.84   15.84   15.84

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             2
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             1

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 22:46:56.248 2009  to  Sat May  9 22:47:44.132 2009   ( 47.88) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   2  FAILED    IIF        command.preset.(GUIDE)                                        Sat May  9 22:48:52.429 2009  to  Sat May  9 22:48:57.736 2009   (  5.31) secs
                     IIF Preset command started for left IRTC mode GUIDE from IIF
                     IIF Preset alert for left IRTC mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   3  FAILED    IIF        command.preset.(GUIDE)                                        Sat May  9 22:59:42.262 2009  to  Sat May  9 23:01:30.910 2009   (108.65) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: did not receive full CCD readout from guide camera within timeout period of 6502 ms and for 5 consecutive attempts.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3368                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6736                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     140                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .      11
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    4.58   18.89    0.00   22.11    95.5 %        112        110          5           
                                                                       2.77   19.65    6.67   22.11
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.09    0.09    0.00    0.33    50.0 %        111        222                      
                                                                       0.09    0.09    0.00    0.33
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %        146                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.getEffectiveGuideRate. . . . . . . . . . . . . . . . .                                   100.0 %          8                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .    0.00    3.47    3.47    3.47    99.2 %        130                     1           
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getMaximumGuideRate. . . . . . . . . . . . . . . . . .                                   100.0 %          8                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %        269                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %        149                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          9                                 
                                                                                                   
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    0.67    8.39    6.98    9.05   100.0 %          9          9                      
                                                                       0.67    8.39    6.98    9.05
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.45    0.60    0.13    1.28   100.0 %         10         10                      
                                                                       0.45    0.60    0.13    1.28
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    1.61    4.81    1.90    8.59   100.0 %         10         10                      
                                                                       1.61    4.81    1.90    8.59
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    2.61    4.01    0.06    8.84    46.7 %         15          7                      
                                                                       2.61    4.01    0.06    8.84
     command.setDeltaFocus. . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    8.41   17.12    7.18   44.43    99.2 %        119        118                      
                                                                       8.41   17.12    7.18   44.43
     command.setSendZernikesToPSF . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %        258                                 
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.09   100.0 %         68         68                      
                                                                       0.01    0.06    0.04    0.09
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06   100.0 %          6          6                      
                                                                       0.01    0.06    0.05    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.49    0.57    0.10    2.32    88.7 %        124        110                      
                                                                       0.49    0.57    0.10    2.32
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.02    0.18    0.15    0.26   100.0 %         68         68                      
                                                                       0.02    0.18    0.15    0.26
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    3.95   11.96    6.60   21.22   100.0 %        127        127                      
                                                                       3.95   11.96    6.60   21.22
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.71    1.68    0.00   12.48    99.9 %       5940       5887          5             interrupted =    51
                                                                       1.70    1.68    0.47   12.48
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    6.33   28.62   18.12   46.64    77.3 %        299        231                        interrupted =    68
                                                                       6.33   28.62   18.12   46.64
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.02    0.19    0.16    0.29   100.0 %        128        128                      
                                                                       0.02    0.19    0.16    0.29
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    1.37    0.22    0.14   78.20   100.0 %       5672       5672                        interrupted =     3
                                                                       1.37    0.22    0.14   78.20
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.41    2.20    1.17    2.76   100.0 %        111        111                      
                                                                       0.41    2.20    1.17    2.76
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   64.86   18.92    4.93  722.05    98.9 %        186        184                      
                                                                      64.86   18.92    4.93  722.05
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.05    0.23    0.17    0.55    95.2 %        227        216                      
                                                                       0.05    0.23    0.17    0.55

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .     111                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .      68                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .      68                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .     110                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 12        122
     wfsthread.warning. . . . . . . . . . . . . . . . . . . . . . .                             3

GCS Events of Interest

   1  STARTUP   GCS        startup                                                       Sat May  9 19:52:43.469 2009  to  Sat May  9 19:52:43.469 2009   (  0.00) secs
                     left GCS subsystem started

   2  STARTUP   GCS        startup                                                       Sat May  9 20:08:16.245 2009  to  Sat May  9 20:08:16.245 2009   (  0.00) secs
                     left GCS subsystem started

   3  STARTUP   GCS        startup                                                       Sat May  9 20:10:58.763 2009  to  Sat May  9 20:10:58.763 2009   (  0.00) secs
                     left GCS subsystem started

   4  STARTUP   GCS        startup                                                       Sat May  9 20:13:25.083 2009  to  Sat May  9 20:13:25.083 2009   (  0.00) secs
                     left GCS subsystem started

   5  STARTUP   GCS        startup                                                       Sat May  9 20:16:53.928 2009  to  Sat May  9 20:16:53.928 2009   (  0.00) secs
                     left GCS subsystem started

   6  STARTUP   GCS        startup                                                       Sat May  9 20:27:43.469 2009  to  Sat May  9 20:27:43.469 2009   (  0.00) secs
                     left GCS subsystem started

   7  STARTUP   GCS        startup                                                       Sat May  9 20:31:29.736 2009  to  Sat May  9 20:31:29.736 2009   (  0.00) secs
                     left GCS subsystem started

   8  STARTUP   GCS        startup                                                       Sat May  9 21:13:09.509 2009  to  Sat May  9 21:13:09.509 2009   (  0.00) secs
                     left GCS subsystem started

   9  STARTUP   GCS        startup                                                       Sat May  9 22:48:29.810 2009  to  Sat May  9 22:48:29.810 2009   (  0.00) secs
                     left GCS subsystem started

  10  STARTUP   GCS        startup                                                       Sat May  9 22:49:12.612 2009  to  Sat May  9 22:49:12.612 2009   (  0.00) secs
                     left GCS subsystem started

  11  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:00:24.715 2009  to  Sat May  9 23:00:35.466 2009   ( 10.75) secs
                     1. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  12  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:00:25.161 2009  to  Sat May  9 23:00:35.414 2009   ( 10.25) secs
                     size: full CCD, exptime: 2000 ms
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  13  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:00:49.287 2009  to  Sat May  9 23:00:49.287 2009   (  0.00) secs
                     2. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  14  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:00:49.234 2009  to  Sat May  9 23:00:49.234 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  15  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:03.103 2009  to  Sat May  9 23:01:03.103 2009   (  0.00) secs
                     3. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  16  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:03.050 2009  to  Sat May  9 23:01:03.050 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  17  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:16.914 2009  to  Sat May  9 23:01:16.914 2009   (  0.00) secs
                     4. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  18  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:16.861 2009  to  Sat May  9 23:01:16.861 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  19  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:30.670 2009  to  Sat May  9 23:01:30.670 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  20  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:30.718 2009  to  Sat May  9 23:01:30.718 2009   (  0.00) secs
                     did not receive full CCD readout from guide camera within timeout period of 6502 ms and for 5 consecutive attempts.

  21  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 23:01:46.904 2009  to  Sat May  9 23:01:46.904 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  22  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 23:01:48.248 2009  to  Sat May  9 23:01:48.248 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  23  STARTUP   GCS        startup                                                       Sat May  9 23:01:55.196 2009  to  Sat May  9 23:01:55.196 2009   (  0.00) secs
                     left GCS subsystem started

  24  FAILED    GCS        command.getFullWFImage                                        Sat May  9 23:12:58.823 2009  to  Sat May  9 23:13:02.298 2009   (  3.47) secs
                     couldn''t save full WFS CCD readout to disk: wfsc

  25  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:28.397 2009  to  Sun May 10 01:32:28.397 2009   (  0.00) secs
                     no guide star found

  26  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:33.582 2009  to  Sun May 10 01:32:33.582 2009   (  0.00) secs
                     no guide star found

  27  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:37.297 2009  to  Sun May 10 01:32:37.297 2009   (  0.00) secs
                     no guide star found

  28  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:35.981 2009  to  Sun May 10 01:33:35.981 2009   (  0.00) secs
                     no guide star found

  29  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:39.715 2009  to  Sun May 10 01:33:39.715 2009   (  0.00) secs
                     no guide star found

  30  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:43.165 2009  to  Sun May 10 01:33:43.165 2009   (  0.00) secs
                     no guide star found

  31  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:46.623 2009  to  Sun May 10 01:33:46.623 2009   (  0.00) secs
                     no guide star found

  32  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:45.840 2009  to  Sun May 10 03:07:45.840 2009   (  0.00) secs
                     no guide star found

  33  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:49.928 2009  to  Sun May 10 03:07:49.928 2009   (  0.00) secs
                     no guide star found

  34  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:54.023 2009  to  Sun May 10 03:07:54.023 2009   (  0.00) secs
                     no guide star found

  35  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:58.047 2009  to  Sun May 10 03:07:58.047 2009   (  0.00) secs
                     no guide star found

  36  FAILED    GCS        guidethread.warning                                           Sun May 10 03:08:01.806 2009  to  Sun May 10 03:08:01.806 2009   (  0.00) secs
                     no guide star found
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      11                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            56
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      51                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       8                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      22                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.amplifierFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     238                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     160                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     195                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .     119                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     248                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     119                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     162                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1534                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     494                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 19:23:49.761 2009  to  Sat May  9 19:23:49.761 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:02:53.638 2009  to  Sat May  9 20:02:53.638 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:02:53.645 2009  to  Sat May  9 20:02:53.645 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   4  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Sat May  9 20:02:53.734 2009  to  Sat May  9 20:02:53.734 2009   (  0.00) secs
                     drive cabinet has turned on.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.743 2009  to  Sat May  9 20:02:54.743 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.743 2009  to  Sat May  9 20:02:54.743 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.744 2009  to  Sat May  9 20:02:54.744 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.744 2009  to  Sat May  9 20:02:54.744 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.745 2009  to  Sat May  9 20:02:54.745 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.745 2009  to  Sat May  9 20:02:54.745 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.746 2009  to  Sat May  9 20:02:54.746 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.746 2009  to  Sat May  9 20:02:54.746 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Sat May  9 20:06:30.767 2009  to  Sat May  9 20:06:30.767 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat May  9 20:06:53.676 2009  to  Sat May  9 20:06:53.676 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  15  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat May  9 20:11:18.076 2009  to  Sat May  9 20:11:18.076 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:15:10.600 2009  to  Sat May  9 20:15:10.600 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat May  9 20:15:11.605 2009  to  Sat May  9 20:15:11.605 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  18  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sun May 10 04:57:49.366 2009  to  Sun May 10 04:57:49.366 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    3.17    5.63    0.40   17.15   100.0 %        201        201                      
                                                                       3.17    5.63    0.40   17.15

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %        128        128                      
                                                                       0.01    0.05    0.04    0.11
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.03    0.13   100.0 %       5672       5672                      
                                                                       0.01    0.05    0.03    0.13
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.41    2.06    1.05    2.62   100.0 %        111        111                        largeUpdate =   104
                                                                       0.41    2.06    1.05    2.62
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         15         15                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          9          9                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.10   100.0 %         18         18                      
                                                                       0.01    0.05    0.04    0.10
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %        119        119                      
                                                                       0.00    0.06    0.05    0.06
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.58    0.31    0.88   100.0 %        119        119                      
                                                                       0.20    0.58    0.31    0.88
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.04    0.03    0.00    0.07    50.0 %          4                     2           
                                                                       0.00    0.07    0.07    0.07

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.728 2009  to  Sat May  9 20:11:15.793 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.793 2009  to  Sat May  9 20:11:15.847 2009   (  0.05) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.904 2009  to  Sat May  9 20:11:15.904 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:15:09.379 2009  to  Sat May  9 20:15:09.447 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   5  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:15:09.584 2009  to  Sat May  9 20:15:09.584 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.00    2.06    2.05    2.10   100.0 %        245        245                      
                                                                       0.00    2.06    2.05    2.10
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          2          2                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.94    3.91    0.00   83.21    99.5 %        389        387          2           
                                                                       4.95    3.92    2.05   83.21
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.07   100.0 %          5          5                      
                                                                       0.01    0.06    0.05    0.07

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  3           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       3                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                          3401
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      10                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     245                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            10

PMC Events of Interest

   1  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 19:26:55.829 2009  to  Sat May  9 19:26:55.829 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   2  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 19:26:55.881 2009  to  Sat May  9 19:26:55.881 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   3  FAILED    PMC        thermal.badReceive                                            Sat May  9 19:26:55.934 2009  to  Sat May  9 19:26:55.934 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   4  FAILED    PMC        VxInterface.close                                             Sat May  9 21:30:51.503 2009  to  Sat May  9 21:30:51.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 21:30:51.451 2009  to  Sat May  9 21:30:51.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 23:46:53.394 2009  to  Sat May  9 23:46:53.394 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   7  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 23:46:53.341 2009  to  Sat May  9 23:46:53.341 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   8  FAILED    PMC        thermal.badReceive                                            Sat May  9 23:46:53.447 2009  to  Sat May  9 23:46:53.447 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   9  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:14:31.029 2009  to  Sun May 10 00:14:31.029 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.close                                             Sun May 10 00:14:31.081 2009  to  Sun May 10 00:14:31.081 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:21.200 2009  to  Sun May 10 00:17:22.328 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:22.328 2009  to  Sun May 10 00:17:22.381 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  13  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:24.259 2009  to  Sun May 10 00:17:24.259 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  14  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:37:47.516 2009  to  Sun May 10 00:37:47.516 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Sun May 10 00:37:47.568 2009  to  Sun May 10 00:37:47.568 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:50:35.298 2009  to  Sun May 10 00:50:35.298 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.close                                             Sun May 10 00:50:35.349 2009  to  Sun May 10 00:50:35.349 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:58:35.423 2009  to  Sun May 10 00:58:35.423 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Sun May 10 00:58:35.476 2009  to  Sun May 10 00:58:35.476 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 01:26:45.463 2009  to  Sun May 10 01:26:45.463 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Sun May 10 01:26:45.515 2009  to  Sun May 10 01:26:45.515 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.close                                             Sun May 10 02:12:54.789 2009  to  Sun May 10 02:12:54.789 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 02:12:54.736 2009  to  Sun May 10 02:12:54.736 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  24  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 03:13:09.593 2009  to  Sun May 10 03:13:09.593 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  25  FAILED    PMC        VxInterface.close                                             Sun May 10 03:13:09.646 2009  to  Sun May 10 03:13:09.646 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  26  FAILED    PMC        VxInterface.packetReadError                                   Sun May 10 03:57:15.827 2009  to  Sun May 10 03:57:15.827 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  27  FAILED    PMC        VxInterface.selectTimeout                                     Sun May 10 03:57:15.775 2009  to  Sun May 10 03:57:15.775 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  28  FAILED    PMC        thermal.badReceive                                            Sun May 10 03:57:15.879 2009  to  Sun May 10 03:57:15.879 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  29  FAILED    PMC        VxInterface.close                                             Sun May 10 04:20:57.816 2009  to  Sun May 10 04:20:57.816 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 04:20:57.764 2009  to  Sun May 10 04:20:57.764 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.close                                             Sun May 10 04:31:18.321 2009  to  Sun May 10 04:31:18.321 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 04:31:18.269 2009  to  Sun May 10 04:31:18.269 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun May 10 05:05:21.565 2009  to  Sun May 10 05:05:28.632 2009   (  7.07) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.99    9.54    4.65   18.29   100.0 %        248        248                      
                                                                       2.99    9.54    4.65   18.29
     command.config . . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.move . . . . . . . . . . . . . . . . . . . . . . . . .    5.21    6.94    2.40   20.72   100.0 %         16         16                      
                                                                       5.21    6.94    2.40   20.72
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.53    0.38    0.27    4.59   100.0 %        126        126                      
                                                                       0.53    0.38    0.27    4.59
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    0.00   13.18   13.18   13.18   100.0 %          1          1                      
                                                                       0.00   13.18   13.18   13.18
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.31    0.21    0.05    0.68    75.0 %          4          3          1           
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.98    9.67    4.76   18.40   100.0 %        248        248                      
                                                                       2.98    9.67    4.76   18.40
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    1.90    7.06    0.19   12.15   100.0 %        249        249                      
                                                                       1.90    7.06    0.19   12.15
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.94    4.05    0.00   83.34    99.5 %        389        387          2           
                                                                       4.95    4.06    2.18   83.34
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          1          1                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.88    2.82    2.20    3.44   100.0 %          2          2                      
                                                                       0.88    2.82    2.20    3.44
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.10    0.07    0.89   100.0 %       1357       1357                      
                                                                       0.04    0.10    0.07    0.89
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.16    0.17    0.06    0.28    50.0 %          2          1          1           
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   21.25   26.59   11.56   41.62    50.0 %          2          1          1           
                                                                       0.00   41.62   41.62   41.62
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   39.74   23.84    3.30   83.45   100.0 %          4          4                      
                                                                      39.74   23.84    3.30   83.45
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    0.76    2.80    2.29    4.30   100.0 %          8          8                      
                                                                       0.76    2.80    2.29    4.30
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.05    0.05    0.11   100.0 %        127        127                      
                                                                       0.01    0.05    0.05    0.11
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    4.96    6.80    3.30   10.31   100.0 %          2          2                      
                                                                       4.96    6.80    3.30   10.31
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.05    0.10   100.0 %        249        249                      
                                                                       0.01    0.06    0.05    0.10
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.41    8.27    0.64   11.39   100.0 %         66         66                      
                                                                       1.41    8.27    0.64   11.39
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    3.17    5.75    0.52   17.27   100.0 %        201        201                      
                                                                       3.17    5.75    0.52   17.27
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.06    0.05    0.13   100.0 %        127        127                      
                                                                       0.01    0.06    0.05    0.13
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.04    0.09    0.06    0.12   100.0 %          2          2                      
                                                                       0.04    0.09    0.06    0.12
     secondaryMirror.command.setLocalOffsets. . . . . . . . . . . .    4.86    9.15    2.72   17.38   100.0 %          9          9                      
                                                                       4.86    9.15    2.72   17.38
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.00    0.05    0.05    0.08   100.0 %         66         66                      
                                                                       0.00    0.05    0.05    0.08
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     primaryMirror.positionError. . . . . . . . . . . . . . . . . .                  1           

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Sat May  9 20:11:16.117 2009  to  Sat May  9 20:11:16.798 2009   (  0.68) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sat May  9 20:11:16.170 2009  to  Sat May  9 20:11:16.450 2009   (  0.28) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:21.137 2009  to  Sun May 10 00:17:22.265 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:22.265 2009  to  Sun May 10 00:17:22.447 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:24.328 2009  to  Sun May 10 00:17:24.328 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   6  FAILED    PSF        primaryMirror.positionError                                   Sun May 10 02:23:03.474 2009  to  Sun May 10 02:23:03.474 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.7990036e-04 -3.9514899e-04 1.5032291e-04 1.0639191e-02 1.5382385e-01 9.5105171e-04

   7  FAILED    PSF        primaryMirror.command.revert                                  Sun May 10 05:05:17.212 2009  to  Sun May 10 05:05:28.775 2009   ( 11.56) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 05:05:21.481 2009  to  Sun May 10 05:05:28.707 2009   (  7.23) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 19:23:49.761 2009  to  Sat May  9 19:23:49.761 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 19:26:55.829 2009  to  Sat May  9 19:26:55.829 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   3  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 19:26:55.881 2009  to  Sat May  9 19:26:55.881 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   4  FAILED    PMC        thermal.badReceive                                            Sat May  9 19:26:55.934 2009  to  Sat May  9 19:26:55.934 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   5  STARTUP   GCS        startup                                                       Sat May  9 19:52:43.469 2009  to  Sat May  9 19:52:43.469 2009   (  0.00) secs
                     left GCS subsystem started

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:02:53.638 2009  to  Sat May  9 20:02:53.638 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:02:53.645 2009  to  Sat May  9 20:02:53.645 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   8  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Sat May  9 20:02:53.734 2009  to  Sat May  9 20:02:53.734 2009   (  0.00) secs
                     drive cabinet has turned on.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.743 2009  to  Sat May  9 20:02:54.743 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.743 2009  to  Sat May  9 20:02:54.743 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.744 2009  to  Sat May  9 20:02:54.744 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.744 2009  to  Sat May  9 20:02:54.744 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.745 2009  to  Sat May  9 20:02:54.745 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.745 2009  to  Sat May  9 20:02:54.745 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.746 2009  to  Sat May  9 20:02:54.746 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sat May  9 20:02:54.746 2009  to  Sat May  9 20:02:54.746 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Sat May  9 20:06:30.767 2009  to  Sat May  9 20:06:30.767 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  18  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat May  9 20:06:53.676 2009  to  Sat May  9 20:06:53.676 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  19  STARTUP   GCS        startup                                                       Sat May  9 20:08:16.245 2009  to  Sat May  9 20:08:16.245 2009   (  0.00) secs
                     left GCS subsystem started

  20  STARTUP   GCS        startup                                                       Sat May  9 20:10:58.763 2009  to  Sat May  9 20:10:58.763 2009   (  0.00) secs
                     left GCS subsystem started

  21  FAILED    IIF GUI    IIFCommand.authorize                                          Sat May  9 20:11:15.658 2009  to  Sat May  9 20:11:17.077 2009   (  1.42) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  22  FAILED    IIF GUI    IIFCommand.authorize                                          Sat May  9 20:11:15.661 2009  to  Sat May  9 20:11:16.179 2009   (  0.52) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  23  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.728 2009  to  Sat May  9 20:11:15.793 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  24  FAILED    PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.793 2009  to  Sat May  9 20:11:15.847 2009   (  0.05) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  25  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:11:15.904 2009  to  Sat May  9 20:11:15.904 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  26  FAILED    PSF        command.setNewInstrument                                      Sat May  9 20:11:16.117 2009  to  Sat May  9 20:11:16.798 2009   (  0.68) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

  27  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sat May  9 20:11:16.170 2009  to  Sat May  9 20:11:16.450 2009   (  0.28) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  28  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat May  9 20:11:18.076 2009  to  Sat May  9 20:11:18.076 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  29  STARTUP   GCS        startup                                                       Sat May  9 20:13:25.083 2009  to  Sat May  9 20:13:25.083 2009   (  0.00) secs
                     left GCS subsystem started

  30  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:15:09.379 2009  to  Sat May  9 20:15:09.447 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  31  SEQERROR  PCS        telescope.command.stopTracking                                Sat May  9 20:15:09.584 2009  to  Sat May  9 20:15:09.584 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat May  9 20:15:10.600 2009  to  Sat May  9 20:15:10.600 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat May  9 20:15:11.605 2009  to  Sat May  9 20:15:11.605 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  34  STARTUP   GCS        startup                                                       Sat May  9 20:16:53.928 2009  to  Sat May  9 20:16:53.928 2009   (  0.00) secs
                     left GCS subsystem started

  35  STARTUP   GCS        startup                                                       Sat May  9 20:27:43.469 2009  to  Sat May  9 20:27:43.469 2009   (  0.00) secs
                     left GCS subsystem started

  36  STARTUP   GCS        startup                                                       Sat May  9 20:31:29.736 2009  to  Sat May  9 20:31:29.736 2009   (  0.00) secs
                     left GCS subsystem started

  37  STARTUP   GCS        startup                                                       Sat May  9 21:13:09.509 2009  to  Sat May  9 21:13:09.509 2009   (  0.00) secs
                     left GCS subsystem started

  38  FAILED    PMC        VxInterface.close                                             Sat May  9 21:30:51.503 2009  to  Sat May  9 21:30:51.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 21:30:51.451 2009  to  Sat May  9 21:30:51.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  40  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 22:46:56.248 2009  to  Sat May  9 22:47:44.132 2009   ( 47.88) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  41  STARTUP   GCS        startup                                                       Sat May  9 22:48:29.810 2009  to  Sat May  9 22:48:29.810 2009   (  0.00) secs
                     left GCS subsystem started

  42  FAILED    IIF        command.preset.(GUIDE)                                        Sat May  9 22:48:52.429 2009  to  Sat May  9 22:48:57.736 2009   (  5.31) secs
                     IIF Preset command started for left IRTC mode GUIDE from IIF
                     IIF Preset alert for left IRTC mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  43  STARTUP   GCS        startup                                                       Sat May  9 22:49:12.612 2009  to  Sat May  9 22:49:12.612 2009   (  0.00) secs
                     left GCS subsystem started

  44  FAILED    IIF        command.preset.(GUIDE)                                        Sat May  9 22:59:42.262 2009  to  Sat May  9 23:01:30.910 2009   (108.65) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: did not receive full CCD readout from guide camera within timeout period of 6502 ms and for 5 consecutive attempts.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  45  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:00:24.715 2009  to  Sat May  9 23:00:35.466 2009   ( 10.75) secs
                     1. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  46  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:00:25.161 2009  to  Sat May  9 23:00:35.414 2009   ( 10.25) secs
                     size: full CCD, exptime: 2000 ms
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  47  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:00:49.287 2009  to  Sat May  9 23:00:49.287 2009   (  0.00) secs
                     2. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  48  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:00:49.234 2009  to  Sat May  9 23:00:49.234 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  49  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:03.103 2009  to  Sat May  9 23:01:03.103 2009   (  0.00) secs
                     3. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  50  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:03.050 2009  to  Sat May  9 23:01:03.050 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  51  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:16.914 2009  to  Sat May  9 23:01:16.914 2009   (  0.00) secs
                     4. reception of image failed to arrive within timeout period of 6502 ms, trying again in 2 seconds...

  52  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:16.861 2009  to  Sat May  9 23:01:16.861 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  53  FAILED    GCS        interface.azcam.guider.readout                                Sat May  9 23:01:30.670 2009  to  Sat May  9 23:01:30.670 2009   (  0.00) secs
                     in autoAcquireGuidestar: timeout occured waiting for an image to arrive from AzCam server

  54  FAILED    GCS        command.autoAcquireGuidestar                                  Sat May  9 23:01:30.718 2009  to  Sat May  9 23:01:30.718 2009   (  0.00) secs
                     did not receive full CCD readout from guide camera within timeout period of 6502 ms and for 5 consecutive attempts.

  55  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 23:01:46.904 2009  to  Sat May  9 23:01:46.904 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  56  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 23:01:48.248 2009  to  Sat May  9 23:01:48.248 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  57  STARTUP   GCS        startup                                                       Sat May  9 23:01:55.196 2009  to  Sat May  9 23:01:55.196 2009   (  0.00) secs
                     left GCS subsystem started

  58  FAILED    GCS        command.getFullWFImage                                        Sat May  9 23:12:58.823 2009  to  Sat May  9 23:13:02.298 2009   (  3.47) secs
                     couldn''t save full WFS CCD readout to disk: wfsc

  59  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 23:46:53.394 2009  to  Sat May  9 23:46:53.394 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  60  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 23:46:53.341 2009  to  Sat May  9 23:46:53.341 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  61  FAILED    PMC        thermal.badReceive                                            Sat May  9 23:46:53.447 2009  to  Sat May  9 23:46:53.447 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  62  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:14:31.029 2009  to  Sun May 10 00:14:31.029 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Sun May 10 00:14:31.081 2009  to  Sun May 10 00:14:31.081 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  64  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:21.137 2009  to  Sun May 10 00:17:22.265 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  65  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:21.200 2009  to  Sun May 10 00:17:22.328 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:22.265 2009  to  Sun May 10 00:17:22.447 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:22.328 2009  to  Sun May 10 00:17:22.381 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun May 10 00:17:24.259 2009  to  Sun May 10 00:17:24.259 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  69  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 00:17:24.328 2009  to  Sun May 10 00:17:24.328 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  70  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:37:47.516 2009  to  Sun May 10 00:37:47.516 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Sun May 10 00:37:47.568 2009  to  Sun May 10 00:37:47.568 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:50:35.298 2009  to  Sun May 10 00:50:35.298 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  73  FAILED    PMC        VxInterface.close                                             Sun May 10 00:50:35.349 2009  to  Sun May 10 00:50:35.349 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 00:58:35.423 2009  to  Sun May 10 00:58:35.423 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  75  FAILED    PMC        VxInterface.close                                             Sun May 10 00:58:35.476 2009  to  Sun May 10 00:58:35.476 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 01:26:45.463 2009  to  Sun May 10 01:26:45.463 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Sun May 10 01:26:45.515 2009  to  Sun May 10 01:26:45.515 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  78  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:28.397 2009  to  Sun May 10 01:32:28.397 2009   (  0.00) secs
                     no guide star found

  79  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:33.582 2009  to  Sun May 10 01:32:33.582 2009   (  0.00) secs
                     no guide star found

  80  FAILED    GCS        guidethread.warning                                           Sun May 10 01:32:37.297 2009  to  Sun May 10 01:32:37.297 2009   (  0.00) secs
                     no guide star found

  81  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:35.981 2009  to  Sun May 10 01:33:35.981 2009   (  0.00) secs
                     no guide star found

  82  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:39.715 2009  to  Sun May 10 01:33:39.715 2009   (  0.00) secs
                     no guide star found

  83  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:43.165 2009  to  Sun May 10 01:33:43.165 2009   (  0.00) secs
                     no guide star found

  84  FAILED    GCS        guidethread.warning                                           Sun May 10 01:33:46.623 2009  to  Sun May 10 01:33:46.623 2009   (  0.00) secs
                     no guide star found

  85  FAILED    PMC        VxInterface.close                                             Sun May 10 02:12:54.789 2009  to  Sun May 10 02:12:54.789 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  86  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 02:12:54.736 2009  to  Sun May 10 02:12:54.736 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  87  FAILED    PSF        primaryMirror.positionError                                   Sun May 10 02:23:03.474 2009  to  Sun May 10 02:23:03.474 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 9.7990036e-04 -3.9514899e-04 1.5032291e-04 1.0639191e-02 1.5382385e-01 9.5105171e-04

  88  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:45.840 2009  to  Sun May 10 03:07:45.840 2009   (  0.00) secs
                     no guide star found

  89  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:49.928 2009  to  Sun May 10 03:07:49.928 2009   (  0.00) secs
                     no guide star found

  90  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:54.023 2009  to  Sun May 10 03:07:54.023 2009   (  0.00) secs
                     no guide star found

  91  FAILED    GCS        guidethread.warning                                           Sun May 10 03:07:58.047 2009  to  Sun May 10 03:07:58.047 2009   (  0.00) secs
                     no guide star found

  92  FAILED    GCS        guidethread.warning                                           Sun May 10 03:08:01.806 2009  to  Sun May 10 03:08:01.806 2009   (  0.00) secs
                     no guide star found

  93  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 03:13:09.593 2009  to  Sun May 10 03:13:09.593 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  94  FAILED    PMC        VxInterface.close                                             Sun May 10 03:13:09.646 2009  to  Sun May 10 03:13:09.646 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  95  FAILED    PMC        VxInterface.packetReadError                                   Sun May 10 03:57:15.827 2009  to  Sun May 10 03:57:15.827 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  96  FAILED    PMC        VxInterface.selectTimeout                                     Sun May 10 03:57:15.775 2009  to  Sun May 10 03:57:15.775 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  97  FAILED    PMC        thermal.badReceive                                            Sun May 10 03:57:15.879 2009  to  Sun May 10 03:57:15.879 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  98  FAILED    PMC        VxInterface.close                                             Sun May 10 04:20:57.816 2009  to  Sun May 10 04:20:57.816 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  99  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 04:20:57.764 2009  to  Sun May 10 04:20:57.764 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 100  FAILED    PMC        VxInterface.close                                             Sun May 10 04:31:18.321 2009  to  Sun May 10 04:31:18.321 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 101  FAILED    PMC        VxInterface.lengthError                                       Sun May 10 04:31:18.269 2009  to  Sun May 10 04:31:18.269 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 102  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sun May 10 04:57:49.366 2009  to  Sun May 10 04:57:49.366 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 103  FAILED    PSF        primaryMirror.command.revert                                  Sun May 10 05:05:17.212 2009  to  Sun May 10 05:05:28.775 2009   ( 11.56) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

 104  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun May 10 05:05:21.481 2009  to  Sun May 10 05:05:28.707 2009   (  7.23) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 105  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun May 10 05:05:21.565 2009  to  Sun May 10 05:05:28.632 2009   (  7.07) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

**********************************************************
    Reporting period ending:   Sun May 10 05:53:58.335 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback