             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   16.03   11.78    0.44   23.12    50.0 %          2          1          1           
                                                                       0.00    0.44    0.44    0.44

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Fri May  8 18:50:31.639 2009  to  Fri May  8 18:50:54.758 2009   ( 23.12) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    6.61   17.31   11.33   56.27    94.9 %         59         56                     3
                                                                       6.61   17.31   11.33   56.27
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.54    2.99    2.07    4.26   100.0 %         59         59                      
                                                                       0.54    2.99    2.07    4.26
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   76.83   76.65   21.17  215.63   100.0 %          6          6                      
                                                                      76.83   76.65   21.17  215.63
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   25.38   59.25    4.25  187.18    91.0 %        111         61         10         40
                                                                      15.07   58.00   36.54  110.45
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    4.47    2.74    2.07   38.12   100.0 %        114        114                      
                                                                       4.47    2.74    2.07   38.12
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   21.03    6.52    2.07  160.35   100.0 %        114        114                      
                                                                      21.03    6.52    2.07  160.35
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    0.00   20.49   20.49   20.49   100.0 %          1          1                      
                                                                       0.00   20.49   20.49   20.49

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             2
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             1

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 19:46:47.598 2009  to  Fri May  8 19:47:35.816 2009   ( 48.22) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 304
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   2  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 19:48:15.665 2009  to  Fri May  8 19:49:32.395 2009   ( 76.73) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 263
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   3  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 20:14:22.086 2009  to  Fri May  8 20:17:29.264 2009   (187.18) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 426
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   4  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 20:30:03.112 2009  to  Fri May  8 20:31:30.252 2009   ( 87.14) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   5  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 22:51:55.857 2009  to  Fri May  8 22:52:44.301 2009   ( 48.44) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 117
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   6  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 23:05:41.275 2009  to  Fri May  8 23:07:01.807 2009   ( 80.53) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 87
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   7  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:23:16.746 2009  to  Sat May  9 01:23:22.110 2009   (  5.36) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   8  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:24:22.229 2009  to  Sat May  9 01:24:27.674 2009   (  5.45) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   9  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:25:16.811 2009  to  Sat May  9 01:25:21.065 2009   (  4.25) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  10  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 04:21:26.417 2009  to  Sat May  9 04:23:32.095 2009   (125.68) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3378                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6757                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      65                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    6.48   20.32    0.00   38.05    94.5 %        109        108          6          3
                                                                       5.83   20.07    0.00   25.88
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.63    0.13    0.00    9.26    99.5 %        109        216          1           
                                                                       0.09    0.09    0.00    0.58
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    0.00    6.60    6.60    6.60   100.0 %          1          1                      
                                                                       0.00    6.60    6.60    6.60
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.getEffectiveGuideRate. . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getMaximumGuideRate. . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          8                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    0.57    7.74    6.69    8.96   100.0 %         59         59                      
                                                                       0.57    7.74    6.69    8.96
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.21    0.23    0.10    1.04   100.0 %         59         59                      
                                                                       0.21    0.23    0.10    1.04
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    1.19    4.00    0.00   10.05   100.0 %         59         59                     2
                                                                       1.19    4.00    0.00   10.05
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    1.60    2.87    1.74    3.99   100.0 %          2          2                      
                                                                       1.60    2.87    1.74    3.99
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          7                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .   10.36   16.24    7.19   42.33    97.4 %        117        114                      
                                                                      10.36   16.24    7.19   42.33
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.11   100.0 %        102        102                      
                                                                       0.01    0.06    0.04    0.11
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.08   100.0 %          6          6                      
                                                                       0.01    0.06    0.05    0.08
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.46    0.65    0.35    2.30    84.3 %        121        102                      
                                                                       0.46    0.65    0.35    2.30
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.09    0.20    0.16    0.91   100.0 %        102        102                      
                                                                       0.09    0.20    0.16    0.91
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    2.60    8.98    6.36   21.72   100.0 %        173        173                      
                                                                       2.60    8.98    6.36   21.72
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.42    2.49    0.67   13.57    98.4 %       6806       6698                        interrupted =   108
                                                                       1.42    2.49    0.67   13.57
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    2.90   33.11   32.33   53.16    84.3 %        573        483                        interrupted =    90
                                                                       2.90   33.11   32.33   53.16
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.02    0.19    0.16    0.32   100.0 %        176        176                      
                                                                       0.02    0.19    0.16    0.32
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    5.60    0.29    0.13  439.04   100.0 %       6473       6473                        interrupted =     8
                                                                       5.60    0.29    0.13  439.04
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.46    2.14    1.17    3.51   100.0 %        108        108                      
                                                                       0.46    2.14    1.17    3.51
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   26.31   18.78    5.20  448.66   100.0 %        475        475                      
                                                                      26.31   18.78    5.20  448.66
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.05    0.22    0.15    0.66    99.6 %        482        480                      
                                                                       0.05    0.22    0.15    0.66

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .     108                      
 *** guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 27        101
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .     108                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .     102                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .     102                      
     wfsthread.warning. . . . . . . . . . . . . . . . . . . . . . .                             1

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 19:47:12.919 2009  to  Fri May  8 19:47:35.318 2009   ( 22.40) secs
                     guiding was not stable within 6 cycles

   2  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 19:48:53.842 2009  to  Fri May  8 19:49:31.893 2009   ( 38.05) secs
                     guiding was not stable within 6 cycles

   3  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 20:16:59.797 2009  to  Fri May  8 20:17:28.769 2009   ( 28.97) secs
                     guiding was not stable within 6 cycles

   4  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 20:30:52.320 2009  to  Fri May  8 20:31:29.901 2009   ( 37.58) secs
                     guiding was not stable within 6 cycles

   5  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:44.714 2009  to  Fri May  8 21:39:44.714 2009   (  0.00) secs
                     no guide star found

   6  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:47.701 2009  to  Fri May  8 21:39:47.701 2009   (  0.00) secs
                     no guide star found

   7  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:50.794 2009  to  Fri May  8 21:39:50.794 2009   (  0.00) secs
                     no guide star found

   8  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:53.684 2009  to  Fri May  8 21:39:53.684 2009   (  0.00) secs
                     no guide star found

   9  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:56.534 2009  to  Fri May  8 21:39:56.534 2009   (  0.00) secs
                     no guide star found

  10  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:59.518 2009  to  Fri May  8 21:39:59.518 2009   (  0.00) secs
                     no guide star found

  11  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:26.568 2009  to  Fri May  8 21:40:26.568 2009   (  0.00) secs
                     no guide star found

  12  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:29.566 2009  to  Fri May  8 21:40:29.566 2009   (  0.00) secs
                     no guide star found

  13  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:32.394 2009  to  Fri May  8 21:40:32.394 2009   (  0.00) secs
                     no guide star found

  14  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:35.895 2009  to  Fri May  8 21:40:35.895 2009   (  0.00) secs
                     no guide star found

  15  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:48.601 2009  to  Fri May  8 21:40:48.601 2009   (  0.00) secs
                     no guide star found

  16  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:51.618 2009  to  Fri May  8 21:40:51.618 2009   (  0.00) secs
                     no guide star found

  17  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:54.564 2009  to  Fri May  8 21:40:54.564 2009   (  0.00) secs
                     no guide star found

  18  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:57.401 2009  to  Fri May  8 21:40:57.401 2009   (  0.00) secs
                     no guide star found

  19  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:00.439 2009  to  Fri May  8 21:41:00.439 2009   (  0.00) secs
                     no guide star found

  20  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:03.424 2009  to  Fri May  8 21:41:03.424 2009   (  0.00) secs
                     no guide star found

  21  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:06.388 2009  to  Fri May  8 21:41:06.388 2009   (  0.00) secs
                     no guide star found

  22  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:09.444 2009  to  Fri May  8 21:41:09.444 2009   (  0.00) secs
                     no guide star found

  23  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:12.494 2009  to  Fri May  8 21:41:12.494 2009   (  0.00) secs
                     no guide star found

  24  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:15.553 2009  to  Fri May  8 21:41:15.553 2009   (  0.00) secs
                     no guide star found

  25  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:18.607 2009  to  Fri May  8 21:41:18.607 2009   (  0.00) secs
                     no guide star found

  26  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:21.724 2009  to  Fri May  8 21:41:21.724 2009   (  0.00) secs
                     no guide star found

  27  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:24.780 2009  to  Fri May  8 21:41:24.780 2009   (  0.00) secs
                     no guide star found

  28  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:27.917 2009  to  Fri May  8 21:41:27.917 2009   (  0.00) secs
                     no guide star found

  29  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:31.051 2009  to  Fri May  8 21:41:31.051 2009   (  0.00) secs
                     no guide star found

  30  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 22:52:21.336 2009  to  Fri May  8 22:52:43.808 2009   ( 22.47) secs
                     guiding was not stable within 6 cycles

  31  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 23:07:01.301 2009  to  Fri May  8 23:07:01.301 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

  32  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 01:22:17.001 2009  to  Sat May  9 01:22:17.001 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  33  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 01:22:17.583 2009  to  Sat May  9 01:22:17.583 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  34  STARTUP   GCS        startup                                                       Sat May  9 01:22:23.187 2009  to  Sat May  9 01:22:23.187 2009   (  0.00) secs
                     left GCS subsystem started

  35  STARTUP   GCS        startup                                                       Sat May  9 01:23:31.562 2009  to  Sat May  9 01:23:31.562 2009   (  0.00) secs
                     left GCS subsystem started

  36  STARTUP   GCS        startup                                                       Sat May  9 01:24:34.614 2009  to  Sat May  9 01:24:34.614 2009   (  0.00) secs
                     left GCS subsystem started

  37  STARTUP   GCS        startup                                                       Sat May  9 01:28:37.489 2009  to  Sat May  9 01:28:37.489 2009   (  0.00) secs
                     left GCS subsystem started

  38  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sat May  9 04:23:22.541 2009  to  Sat May  9 04:23:31.804 2009   (  9.26) secs
                     couldn''t find a star in any GS location.
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            20
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     234                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     135                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     152                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .     117                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     117                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     142                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     285                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1876                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     612                      
     MCSPU.RTracker.trackLimitWarning . . . . . . . . . . . . . . .      11                      
     MCSPU.RTracker.doingUnwrap . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .       9                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri May  8 18:50:32.903 2009  to  Fri May  8 18:50:32.903 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri May  8 18:50:33.919 2009  to  Fri May  8 18:50:33.919 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.847 2009  to  Fri May  8 19:41:48.847 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742819123e+09 but t0 of the AZ target polynomial is 4.748550665838000e+09. Difference= 3.076981122970581e+03 seq=1705455

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.848 2009  to  Fri May  8 19:41:48.848 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742820871e+09 but t0 of the EL target polynomial is 4.748515616774000e+09. Difference= 3.812604687118530e+04 seq=1004854

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.849 2009  to  Fri May  8 19:41:48.849 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742736571e+09 but t0 of the LFBG target polynomial is 4.748550665838000e+09. Difference= 3.076898571014404e+03 seq=1705455

   6  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sat May  9 05:03:18.448 2009  to  Sat May  9 05:03:18.448 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    1.92    7.93    0.35   20.40   100.0 %        641        641                      
                                                                       1.92    7.93    0.35   20.40
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.33    2.91    2.35    3.47   100.0 %        114        114                      
                                                                       0.33    2.91    2.35    3.47
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.00   21.66   21.66   21.66   100.0 %          1          1                      
                                                                       0.00   21.66   21.66   21.66

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             1

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %        176        176                      
                                                                       0.01    0.05    0.04    0.11
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.03    0.13   100.0 %       6473       6473                      
                                                                       0.01    0.05    0.03    0.13
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.46    2.00    1.05    3.38   100.0 %        108        108                        largeUpdate =   101
                                                                       0.46    2.00    1.05    3.38
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         18         18                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.00    0.05    0.05    0.07   100.0 %         59         59                      
                                                                       0.00    0.05    0.05    0.07
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.07   100.0 %         24         24                      
                                                                       0.01    0.05    0.04    0.07
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.06    0.05    0.09   100.0 %        117        117                      
                                                                       0.00    0.06    0.05    0.09
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.56    0.31    0.87   100.0 %        117        117                      
                                                                       0.20    0.56    0.31    0.87
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.04    0.00    0.08     0.0 %          2                     2           
                                                                       0.00    0.08    0.08    0.08

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Fri May  8 18:50:31.716 2009  to  Fri May  8 18:50:31.781 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   2  SEQERROR  PCS        telescope.command.stopTracking                                Fri May  8 18:50:31.923 2009  to  Fri May  8 18:50:31.923 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.10    2.06    2.05    4.06   100.0 %        472        472                      
                                                                       0.10    2.06    2.05    4.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    6.38    5.01    0.00   47.14    99.4 %        178        177          1           
                                                                       6.39    5.06    2.05   47.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                            14
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       8                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     472                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             5
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  3           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           

PMC Events of Interest

   1  FAILED    PMC        VxInterface.close                                             Fri May  8 19:45:28.689 2009  to  Fri May  8 19:45:28.689 2009   (  0.00) secs
                     left PMC PMC closing network connection

   2  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 19:45:28.637 2009  to  Fri May  8 19:45:28.637 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

   3  FAILED    PMC        VxInterface.close                                             Fri May  8 19:47:05.874 2009  to  Fri May  8 19:47:05.874 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 19:47:05.822 2009  to  Fri May  8 19:47:05.822 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.packetReadError                                   Fri May  8 21:35:22.212 2009  to  Fri May  8 21:35:22.212 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   6  FAILED    PMC        VxInterface.selectTimeout                                     Fri May  8 21:35:22.158 2009  to  Fri May  8 21:35:22.158 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   7  FAILED    PMC        thermal.badReceive                                            Fri May  8 21:35:22.265 2009  to  Fri May  8 21:35:22.265 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   8  FAILED    PMC        VxInterface.close                                             Fri May  8 23:06:16.718 2009  to  Fri May  8 23:06:16.718 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   9  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 23:06:16.667 2009  to  Fri May  8 23:06:16.667 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 23:52:40.036 2009  to  Fri May  8 23:52:40.036 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Fri May  8 23:52:40.088 2009  to  Fri May  8 23:52:40.088 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.close                                             Sat May  9 00:07:38.149 2009  to  Sat May  9 00:07:38.149 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:07:38.097 2009  to  Sat May  9 00:07:38.097 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Sat May  9 00:37:07.877 2009  to  Sat May  9 00:37:07.877 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:37:07.824 2009  to  Sat May  9 00:37:07.824 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  16  FAILED    PMC        VxInterface.close                                             Sat May  9 00:39:15.657 2009  to  Sat May  9 00:39:15.657 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:39:15.605 2009  to  Sat May  9 00:39:15.605 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  18  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 00:43:07.923 2009  to  Sat May  9 00:43:07.923 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  19  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 00:43:07.870 2009  to  Sat May  9 00:43:07.870 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  20  FAILED    PMC        thermal.badReceive                                            Sat May  9 00:43:07.976 2009  to  Sat May  9 00:43:07.976 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  21  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 01:50:28.668 2009  to  Sat May  9 01:50:28.668 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  22  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 01:50:28.615 2009  to  Sat May  9 01:50:28.615 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  23  FAILED    PMC        thermal.badReceive                                            Sat May  9 01:50:28.720 2009  to  Sat May  9 01:50:28.720 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  24  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 02:14:21.328 2009  to  Sat May  9 02:14:21.328 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Sat May  9 02:14:21.380 2009  to  Sat May  9 02:14:21.380 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:31:35.111 2009  to  Sat May  9 04:32:18.773 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:32:18.773 2009  to  Sat May  9 04:32:18.828 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  28  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:32:22.250 2009  to  Sat May  9 04:32:22.250 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    1.54   12.44    4.92   16.44   100.0 %        475        475                      
                                                                       1.54   12.44    4.92   16.44
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    3.16    2.00    0.27   15.35   100.0 %        164        164                      
                                                                       3.16    2.00    0.27   15.35
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    0.00   20.36   20.36   20.36   100.0 %          1          1                      
                                                                       0.00   20.36   20.36   20.36
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.38    0.32    0.05    0.59    50.0 %          2          1          1           
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    1.75   12.59    5.03   30.77   100.0 %        475        475                      
                                                                       1.75   12.59    5.03   30.77
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    0.35    3.84    0.19    5.56   100.0 %        475        475                      
                                                                       0.35    3.84    0.19    5.56
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    6.38    5.14    0.00   47.27    99.4 %        178        177          1           
                                                                       6.39    5.20    2.18   47.27
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          1          1                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.10    0.07    0.95   100.0 %       2712       2712                      
                                                                       0.04    0.10    0.07    0.95
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.05    0.09    0.06    0.12    50.0 %          2          1          1           
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00    4.54    4.54    4.54   100.0 %          1          1                      
                                                                       0.00    4.54    4.54    4.54
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   11.66    9.21    0.30   39.37    88.9 %          9          8          1           
                                                                      11.95   10.32    3.37   39.37
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    0.00   11.32   11.32   11.32   100.0 %          1          1                      
                                                                       0.00   11.32   11.32   11.32
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.05    0.05    0.10   100.0 %        165        165                      
                                                                       0.01    0.05    0.05    0.10
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .   24.89   18.66    3.30   47.38   100.0 %          3          3                      
                                                                      24.89   18.66    3.30   47.38
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.11   100.0 %        475        475                      
                                                                       0.00    0.05    0.05    0.11
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.59    8.21    0.58   13.94   100.0 %        475        475                      
                                                                       1.59    8.21    0.58   13.94
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    1.92    8.06    0.47   20.53   100.0 %        641        641                      
                                                                       1.92    8.06    0.47   20.53
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.09   100.0 %        165        165                      
                                                                       0.00    0.05    0.05    0.09
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.00    0.17    0.17    0.17   100.0 %          1          1                      
                                                                       0.00    0.17    0.17    0.17
     secondaryMirror.command.setGlobalOffsets . . . . . . . . . . .    4.78    9.79    2.65   12.68   100.0 %          4          4                      
                                                                       4.78    9.79    2.65   12.68
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.01    0.06    0.05    0.11   100.0 %        475        475                      
                                                                       0.01    0.06    0.05    0.11
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    0.33    3.05    2.47    3.63   100.0 %        114        114                      
                                                                       0.33    3.05    2.47    3.63
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.00    0.08    0.08    0.08   100.0 %          1          1                      
                                                                       0.00    0.08    0.08    0.08

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                183           

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Fri May  8 18:50:32.217 2009  to  Fri May  8 18:50:32.809 2009   (  0.59) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri May  8 18:50:32.269 2009  to  Fri May  8 18:50:32.392 2009   (  0.12) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:31.673 2009  to  Fri May  8 20:01:31.673 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5847504e-02 1.7277747e-02 -2.1725810e-01 4.8191071e-02 7.5428009e-02 -6.1380863e-04

   4  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:31.928 2009  to  Fri May  8 20:01:31.928 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

   5  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.183 2009  to  Fri May  8 20:01:32.183 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.437 2009  to  Fri May  8 20:01:32.437 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.692 2009  to  Fri May  8 20:01:32.692 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.947 2009  to  Fri May  8 20:01:32.947 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.202 2009  to  Fri May  8 20:01:33.202 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.458 2009  to  Fri May  8 20:01:33.458 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6582310e-02 1.8536925e-02 -2.1749079e-01 5.3222656e-02 9.9094391e-02 7.7880621e-03

  11  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.713 2009  to  Fri May  8 20:01:33.713 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6582310e-02 1.8536925e-02 -2.1749079e-01 5.3222656e-02 9.9094391e-02 7.7880621e-03

  12  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.968 2009  to  Fri May  8 20:01:33.968 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5862942e-02 1.7884269e-02 -2.1726310e-01 8.3381653e-02 1.1421967e-01 2.0348549e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.223 2009  to  Fri May  8 20:01:34.223 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5862942e-02 1.7884269e-02 -2.1726310e-01 8.3381653e-02 1.1421967e-01 2.0348549e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.478 2009  to  Fri May  8 20:01:34.478 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.733 2009  to  Fri May  8 20:01:34.733 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.989 2009  to  Fri May  8 20:01:34.989 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6202867e-02 1.7876476e-02 -2.1707964e-01 6.1054230e-02 1.0898590e-01 9.9529028e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.244 2009  to  Fri May  8 20:01:35.244 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.501 2009  to  Fri May  8 20:01:35.501 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.757 2009  to  Fri May  8 20:01:35.757 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.015 2009  to  Fri May  8 20:01:36.015 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6202867e-02 1.7876476e-02 -2.1707964e-01 6.1054230e-02 1.0898590e-01 9.9529028e-03

  21  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.271 2009  to  Fri May  8 20:01:36.271 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.527 2009  to  Fri May  8 20:01:36.527 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.783 2009  to  Fri May  8 20:01:36.783 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.039 2009  to  Fri May  8 20:01:37.039 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5664756e-02 1.7503098e-02 -2.1703720e-01 3.0723572e-02 1.4109421e-01 1.2355685e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.295 2009  to  Fri May  8 20:01:37.295 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6720593e-02 1.8179446e-02 -2.1708357e-01 6.7314148e-02 1.2076759e-01 3.0856490e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.553 2009  to  Fri May  8 20:01:37.553 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6720593e-02 1.8179446e-02 -2.1708357e-01 6.7314148e-02 1.2076759e-01 3.0856490e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.809 2009  to  Fri May  8 20:01:37.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6920447e-02 1.8544674e-02 -2.1730828e-01 7.5431824e-02 9.3889236e-02 1.8128753e-02

  28  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:31:35.048 2009  to  Sat May  9 04:32:18.712 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:32:18.712 2009  to  Sat May  9 04:32:18.895 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  30  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sat May  9 04:32:18.658 2009  to  Sat May  9 04:32:18.954 2009   (  0.30) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  31  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:32:22.314 2009  to  Sat May  9 04:32:22.314 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Fri May  8 18:50:31.639 2009  to  Fri May  8 18:50:54.758 2009   ( 23.12) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   2  SEQERROR  PCS        telescope.command.stopTracking                                Fri May  8 18:50:31.716 2009  to  Fri May  8 18:50:31.781 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   3  SEQERROR  PCS        telescope.command.stopTracking                                Fri May  8 18:50:31.923 2009  to  Fri May  8 18:50:31.923 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   4  FAILED    PSF        command.setNewInstrument                                      Fri May  8 18:50:32.217 2009  to  Fri May  8 18:50:32.809 2009   (  0.59) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

   5  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri May  8 18:50:32.269 2009  to  Fri May  8 18:50:32.392 2009   (  0.12) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri May  8 18:50:32.903 2009  to  Fri May  8 18:50:32.903 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri May  8 18:50:33.919 2009  to  Fri May  8 18:50:33.919 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.847 2009  to  Fri May  8 19:41:48.847 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742819123e+09 but t0 of the AZ target polynomial is 4.748550665838000e+09. Difference= 3.076981122970581e+03 seq=1705455

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.848 2009  to  Fri May  8 19:41:48.848 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742820871e+09 but t0 of the EL target polynomial is 4.748515616774000e+09. Difference= 3.812604687118530e+04 seq=1004854

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri May  8 19:41:48.849 2009  to  Fri May  8 19:41:48.849 2009   (  0.00) secs
                     MJDsec from DSP is 4.748553742736571e+09 but t0 of the LFBG target polynomial is 4.748550665838000e+09. Difference= 3.076898571014404e+03 seq=1705455

  11  FAILED    PMC        VxInterface.close                                             Fri May  8 19:45:28.689 2009  to  Fri May  8 19:45:28.689 2009   (  0.00) secs
                     left PMC PMC closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 19:45:28.637 2009  to  Fri May  8 19:45:28.637 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

  13  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 19:46:47.598 2009  to  Fri May  8 19:47:35.816 2009   ( 48.22) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 304
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  14  FAILED    PMC        VxInterface.close                                             Fri May  8 19:47:05.874 2009  to  Fri May  8 19:47:05.874 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 19:47:05.822 2009  to  Fri May  8 19:47:05.822 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  16  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 19:47:12.919 2009  to  Fri May  8 19:47:35.318 2009   ( 22.40) secs
                     guiding was not stable within 6 cycles

  17  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 19:48:15.665 2009  to  Fri May  8 19:49:32.395 2009   ( 76.73) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 263
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  18  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 19:48:53.842 2009  to  Fri May  8 19:49:31.893 2009   ( 38.05) secs
                     guiding was not stable within 6 cycles

  19  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:31.673 2009  to  Fri May  8 20:01:31.673 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5847504e-02 1.7277747e-02 -2.1725810e-01 4.8191071e-02 7.5428009e-02 -6.1380863e-04

  20  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:31.928 2009  to  Fri May  8 20:01:31.928 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.183 2009  to  Fri May  8 20:01:32.183 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.437 2009  to  Fri May  8 20:01:32.437 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.692 2009  to  Fri May  8 20:01:32.692 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:32.947 2009  to  Fri May  8 20:01:32.947 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.202 2009  to  Fri May  8 20:01:33.202 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6382456e-02 1.8171698e-02 -2.1726608e-01 4.5104980e-02 1.2597275e-01 2.0515800e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.458 2009  to  Fri May  8 20:01:33.458 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6582310e-02 1.8536925e-02 -2.1749079e-01 5.3222656e-02 9.9094391e-02 7.7880621e-03

  27  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.713 2009  to  Fri May  8 20:01:33.713 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6582310e-02 1.8536925e-02 -2.1749079e-01 5.3222656e-02 9.9094391e-02 7.7880621e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:33.968 2009  to  Fri May  8 20:01:33.968 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5862942e-02 1.7884269e-02 -2.1726310e-01 8.3381653e-02 1.1421967e-01 2.0348549e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.223 2009  to  Fri May  8 20:01:34.223 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5862942e-02 1.7884269e-02 -2.1726310e-01 8.3381653e-02 1.1421967e-01 2.0348549e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.478 2009  to  Fri May  8 20:01:34.478 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.733 2009  to  Fri May  8 20:01:34.733 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5840769e-02 1.7807052e-02 -2.1667254e-01 5.9509277e-02 1.5768814e-01 1.2372851e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:34.989 2009  to  Fri May  8 20:01:34.989 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6202867e-02 1.7876476e-02 -2.1707964e-01 6.1054230e-02 1.0898590e-01 9.9529028e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.244 2009  to  Fri May  8 20:01:35.244 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.501 2009  to  Fri May  8 20:01:35.501 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:35.757 2009  to  Fri May  8 20:01:35.757 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.015 2009  to  Fri May  8 20:01:36.015 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6202867e-02 1.7876476e-02 -2.1707964e-01 6.1054230e-02 1.0898590e-01 9.9529028e-03

  37  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.271 2009  to  Fri May  8 20:01:36.271 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.527 2009  to  Fri May  8 20:01:36.527 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:36.783 2009  to  Fri May  8 20:01:36.783 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6364992e-02 1.7580301e-02 -2.1726191e-01 5.4470062e-02 8.7190628e-02 2.0274520e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.039 2009  to  Fri May  8 20:01:37.039 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.5664756e-02 1.7503098e-02 -2.1703720e-01 3.0723572e-02 1.4109421e-01 1.2355685e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.295 2009  to  Fri May  8 20:01:37.295 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6720593e-02 1.8179446e-02 -2.1708357e-01 6.7314148e-02 1.2076759e-01 3.0856490e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.553 2009  to  Fri May  8 20:01:37.553 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6720593e-02 1.8179446e-02 -2.1708357e-01 6.7314148e-02 1.2076759e-01 3.0856490e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Fri May  8 20:01:37.809 2009  to  Fri May  8 20:01:37.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.6920447e-02 1.8544674e-02 -2.1730828e-01 7.5431824e-02 9.3889236e-02 1.8128753e-02

  44  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 20:14:22.086 2009  to  Fri May  8 20:17:29.264 2009   (187.18) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 426
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  45  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 20:16:59.797 2009  to  Fri May  8 20:17:28.769 2009   ( 28.97) secs
                     guiding was not stable within 6 cycles

  46  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 20:30:03.112 2009  to  Fri May  8 20:31:30.252 2009   ( 87.14) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  47  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 20:30:52.320 2009  to  Fri May  8 20:31:29.901 2009   ( 37.58) secs
                     guiding was not stable within 6 cycles

  48  FAILED    PMC        VxInterface.packetReadError                                   Fri May  8 21:35:22.212 2009  to  Fri May  8 21:35:22.212 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  49  FAILED    PMC        VxInterface.selectTimeout                                     Fri May  8 21:35:22.158 2009  to  Fri May  8 21:35:22.158 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  50  FAILED    PMC        thermal.badReceive                                            Fri May  8 21:35:22.265 2009  to  Fri May  8 21:35:22.265 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  51  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:44.714 2009  to  Fri May  8 21:39:44.714 2009   (  0.00) secs
                     no guide star found

  52  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:47.701 2009  to  Fri May  8 21:39:47.701 2009   (  0.00) secs
                     no guide star found

  53  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:50.794 2009  to  Fri May  8 21:39:50.794 2009   (  0.00) secs
                     no guide star found

  54  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:53.684 2009  to  Fri May  8 21:39:53.684 2009   (  0.00) secs
                     no guide star found

  55  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:56.534 2009  to  Fri May  8 21:39:56.534 2009   (  0.00) secs
                     no guide star found

  56  FAILED    GCS        guidethread.warning                                           Fri May  8 21:39:59.518 2009  to  Fri May  8 21:39:59.518 2009   (  0.00) secs
                     no guide star found

  57  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:26.568 2009  to  Fri May  8 21:40:26.568 2009   (  0.00) secs
                     no guide star found

  58  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:29.566 2009  to  Fri May  8 21:40:29.566 2009   (  0.00) secs
                     no guide star found

  59  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:32.394 2009  to  Fri May  8 21:40:32.394 2009   (  0.00) secs
                     no guide star found

  60  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:35.895 2009  to  Fri May  8 21:40:35.895 2009   (  0.00) secs
                     no guide star found

  61  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:48.601 2009  to  Fri May  8 21:40:48.601 2009   (  0.00) secs
                     no guide star found

  62  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:51.618 2009  to  Fri May  8 21:40:51.618 2009   (  0.00) secs
                     no guide star found

  63  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:54.564 2009  to  Fri May  8 21:40:54.564 2009   (  0.00) secs
                     no guide star found

  64  FAILED    GCS        guidethread.warning                                           Fri May  8 21:40:57.401 2009  to  Fri May  8 21:40:57.401 2009   (  0.00) secs
                     no guide star found

  65  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:00.439 2009  to  Fri May  8 21:41:00.439 2009   (  0.00) secs
                     no guide star found

  66  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:03.424 2009  to  Fri May  8 21:41:03.424 2009   (  0.00) secs
                     no guide star found

  67  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:06.388 2009  to  Fri May  8 21:41:06.388 2009   (  0.00) secs
                     no guide star found

  68  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:09.444 2009  to  Fri May  8 21:41:09.444 2009   (  0.00) secs
                     no guide star found

  69  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:12.494 2009  to  Fri May  8 21:41:12.494 2009   (  0.00) secs
                     no guide star found

  70  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:15.553 2009  to  Fri May  8 21:41:15.553 2009   (  0.00) secs
                     no guide star found

  71  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:18.607 2009  to  Fri May  8 21:41:18.607 2009   (  0.00) secs
                     no guide star found

  72  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:21.724 2009  to  Fri May  8 21:41:21.724 2009   (  0.00) secs
                     no guide star found

  73  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:24.780 2009  to  Fri May  8 21:41:24.780 2009   (  0.00) secs
                     no guide star found

  74  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:27.917 2009  to  Fri May  8 21:41:27.917 2009   (  0.00) secs
                     no guide star found

  75  FAILED    GCS        guidethread.warning                                           Fri May  8 21:41:31.051 2009  to  Fri May  8 21:41:31.051 2009   (  0.00) secs
                     no guide star found

  76  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 22:51:55.857 2009  to  Fri May  8 22:52:44.301 2009   ( 48.44) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 117
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  77  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 22:52:21.336 2009  to  Fri May  8 22:52:43.808 2009   ( 22.47) secs
                     guiding was not stable within 6 cycles

  78  FAILED    IIF        command.preset.(ACTIVE)                                       Fri May  8 23:05:41.275 2009  to  Fri May  8 23:07:01.807 2009   ( 80.53) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 87
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  79  FAILED    PMC        VxInterface.close                                             Fri May  8 23:06:16.718 2009  to  Fri May  8 23:06:16.718 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  80  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 23:06:16.667 2009  to  Fri May  8 23:06:16.667 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  81  FAILED    GCS        command.autoAcquireGuidestar                                  Fri May  8 23:07:01.301 2009  to  Fri May  8 23:07:01.301 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

  82  FAILED    PMC        VxInterface.lengthError                                       Fri May  8 23:52:40.036 2009  to  Fri May  8 23:52:40.036 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  83  FAILED    PMC        VxInterface.close                                             Fri May  8 23:52:40.088 2009  to  Fri May  8 23:52:40.088 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  84  FAILED    PMC        VxInterface.close                                             Sat May  9 00:07:38.149 2009  to  Sat May  9 00:07:38.149 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  85  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:07:38.097 2009  to  Sat May  9 00:07:38.097 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  86  FAILED    PMC        VxInterface.close                                             Sat May  9 00:37:07.877 2009  to  Sat May  9 00:37:07.877 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  87  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:37:07.824 2009  to  Sat May  9 00:37:07.824 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  88  FAILED    PMC        VxInterface.close                                             Sat May  9 00:39:15.657 2009  to  Sat May  9 00:39:15.657 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  89  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 00:39:15.605 2009  to  Sat May  9 00:39:15.605 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  90  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 00:43:07.923 2009  to  Sat May  9 00:43:07.923 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  91  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 00:43:07.870 2009  to  Sat May  9 00:43:07.870 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  92  FAILED    PMC        thermal.badReceive                                            Sat May  9 00:43:07.976 2009  to  Sat May  9 00:43:07.976 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  93  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 01:22:17.001 2009  to  Sat May  9 01:22:17.001 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  94  SHUTDOWN  GCS        command.shutdown                                              Sat May  9 01:22:17.583 2009  to  Sat May  9 01:22:17.583 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  95  STARTUP   GCS        startup                                                       Sat May  9 01:22:23.187 2009  to  Sat May  9 01:22:23.187 2009   (  0.00) secs
                     left GCS subsystem started

  96  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:23:16.746 2009  to  Sat May  9 01:23:22.110 2009   (  5.36) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  97  STARTUP   GCS        startup                                                       Sat May  9 01:23:31.562 2009  to  Sat May  9 01:23:31.562 2009   (  0.00) secs
                     left GCS subsystem started

  98  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:24:22.229 2009  to  Sat May  9 01:24:27.674 2009   (  5.45) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  99  STARTUP   GCS        startup                                                       Sat May  9 01:24:34.614 2009  to  Sat May  9 01:24:34.614 2009   (  0.00) secs
                     left GCS subsystem started

 100  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 01:25:16.811 2009  to  Sat May  9 01:25:21.065 2009   (  4.25) secs
                     IIF Preset command started for left IRTC mode ACTIVE from IIF
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 101  STARTUP   GCS        startup                                                       Sat May  9 01:28:37.489 2009  to  Sat May  9 01:28:37.489 2009   (  0.00) secs
                     left GCS subsystem started

 102  FAILED    PMC        VxInterface.packetReadError                                   Sat May  9 01:50:28.668 2009  to  Sat May  9 01:50:28.668 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 103  FAILED    PMC        VxInterface.selectTimeout                                     Sat May  9 01:50:28.615 2009  to  Sat May  9 01:50:28.615 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 104  FAILED    PMC        thermal.badReceive                                            Sat May  9 01:50:28.720 2009  to  Sat May  9 01:50:28.720 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 105  FAILED    PMC        VxInterface.lengthError                                       Sat May  9 02:14:21.328 2009  to  Sat May  9 02:14:21.328 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 106  FAILED    PMC        VxInterface.close                                             Sat May  9 02:14:21.380 2009  to  Sat May  9 02:14:21.380 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 107  FAILED    IIF        command.preset.(ACTIVE)                                       Sat May  9 04:21:26.417 2009  to  Sat May  9 04:23:32.095 2009   (125.68) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 108  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sat May  9 04:23:22.541 2009  to  Sat May  9 04:23:31.804 2009   (  9.26) secs
                     couldn''t find a star in any GS location.

 109  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:31:35.111 2009  to  Sat May  9 04:32:18.773 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 110  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:31:35.048 2009  to  Sat May  9 04:32:18.712 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 111  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:32:18.712 2009  to  Sat May  9 04:32:18.895 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 112  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sat May  9 04:32:18.658 2009  to  Sat May  9 04:32:18.954 2009   (  0.30) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

 113  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:32:18.773 2009  to  Sat May  9 04:32:18.828 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 114  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat May  9 04:32:22.250 2009  to  Sat May  9 04:32:22.250 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

 115  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat May  9 04:32:22.314 2009  to  Sat May  9 04:32:22.314 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 116  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Sat May  9 05:03:18.448 2009  to  Sat May  9 05:03:18.448 2009   (  0.00) secs
                     LFBG axis servo has unexpectedly changed to velocity mode!

**********************************************************
    Reporting period ending:   Sat May  9 05:54:59.772 2009
********************************************************************************************************