You are here: Foswiki>Software Web>TCSSWReportFile_090504 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   May 4 2009 to May 5 2009
 
    Reporting period beginning:   Mon May  4 18:33:06.736 2009
    Reporting period ending:      Tue May  5 05:58:59.277 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    9.17    4.30    0.00   26.18    21.4 %         14          3         11           
                                                                      14.47    8.97    0.60   25.69

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Mon May  4 18:46:18.508 2009  to  Mon May  4 18:46:19.709 2009   (  1.20) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Mon May  4 18:46:18.513 2009  to  Mon May  4 18:46:19.095 2009   (  0.58) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:03:21.855 2009  to  Tue May  5 04:03:48.040 2009   ( 26.18) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   4  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:03:21.861 2009  to  Tue May  5 04:03:22.342 2009   (  0.48) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:04:28.532 2009  to  Tue May  5 04:04:29.779 2009   (  1.25) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:04:28.538 2009  to  Tue May  5 04:04:29.047 2009   (  0.51) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   7  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:04.666 2009  to  Tue May  5 04:06:05.171 2009   (  0.51) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   8  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:04.663 2009  to  Tue May  5 04:06:45.309 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at directGregorian focus

   9  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:45.309 2009  to  Tue May  5 04:06:46.502 2009   (  1.19) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianCenter focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize command failed for left IRTC at bentGregorianCenter focus

  10  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:46.556 2009  to  Tue May  5 04:06:46.556 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  11  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:09:43.954 2009  to  Tue May  5 04:09:44.732 2009   (  0.78) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  12  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:09:43.958 2009  to  Tue May  5 04:09:44.561 2009   (  0.60) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    2.83    9.03    6.49   12.72   100.0 %          5          5                      
                                                                       2.83    9.03    6.49   12.72
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.36    6.55    4.46    7.87   100.0 %          5          5                      
                                                                       1.36    6.55    4.46    7.87
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   70.61  101.56   32.98  181.57   100.0 %          6          6                      
                                                                      70.61  101.56   32.98  181.57
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .    5.52   37.27   30.41   47.50    93.8 %         16         14          1          1
                                                                       5.55   37.61   30.41   47.50
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   34.17   52.01   26.83  135.07    62.5 %          8          5          3           
                                                                       3.06   41.13   37.92   45.76
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    8.82    5.25    2.07   37.21   100.0 %         30         30                      
                                                                       8.82    5.25    2.07   37.21
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   29.77   13.45    2.07  129.30   100.0 %         30         30                      
                                                                      29.77   13.45    2.07  129.30

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                            12
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             1

IIF Events of Interest

   1  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 18:33:38.498 2009  to  Mon May  4 18:35:53.566 2009   (135.07) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   2  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 18:41:28.771 2009  to  Mon May  4 18:41:55.598 2009   ( 26.83) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   3  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 20:57:13.610 2009  to  Mon May  4 20:58:02.119 2009   ( 48.51) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 56
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   4  FAILED    IIF        command.preset.(ACTIVE)                                       Mon May  4 22:48:07.628 2009  to  Mon May  4 22:48:40.061 2009   ( 32.43) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3405                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6812                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      22                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .      15
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .      12

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    5.86   13.23    0.00   29.03    91.7 %         24         22          2           
                                                                       4.98   12.67    0.00   23.80
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.11    0.10    0.00    0.38    95.5 %         24         44          2           
                                                                       0.11    0.10    0.00    0.38
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         41                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         13                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05    50.0 %          4                     2           
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .    1.30    1.35    0.28    3.02     0.0 %          4                     4           
                                                                                                   
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .    2.78    3.46    1.85    6.68    97.7 %        129                     3           
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .   20.05   20.32    0.05   39.35    92.2 %        129                    10           
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         22                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         13                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         42                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         27                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .   13.36    3.60    0.00  100.05    69.8 %         53         53         16           
                                                                       1.35    0.55    0.00    4.64
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         15                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    7.83   15.40   10.08   38.42   100.0 %         30         30                      
                                                                       7.83   15.40   10.08   38.42
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .    9.27    3.63    0.05   32.36    64.7 %         34                    12           
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         15         15                      
                                                                       0.00    0.05    0.05    0.06
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          5          5                      
                                                                       0.00    0.06    0.05    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.14    0.34    0.16    0.55    24.4 %         41         10                      
                                                                       0.14    0.34    0.16    0.55
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.04    0.19    0.16    0.27   100.0 %          5          5                      
                                                                       0.04    0.19    0.16    0.27
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    4.27    9.81    6.85   21.72   100.0 %         30         30                      
                                                                       4.27    9.81    6.85   21.72
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.21    3.87    2.18   10.48    99.8 %       1504       1490          3             interrupted =    11    timeout =     3
                                                                       1.18    3.86    2.18    6.60
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    4.14   34.09   32.33   81.42    99.3 %        148        142          1             interrupted =     5
                                                                       1.13   33.76   32.33   36.41
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.02    0.19    0.17    0.28   100.0 %         30         30                      
                                                                       0.02    0.19    0.17    0.28
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.03    0.20    0.17    0.39   100.0 %       1454       1454                      
                                                                       0.03    0.20    0.17    0.39
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.38    2.21    1.24    2.80   100.0 %         22         22                      
                                                                       0.38    2.21    1.24    2.80
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .    4.74    7.45    3.05   51.76   100.0 %        110        110                      
                                                                       4.74    7.45    3.05   51.76
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.04    0.23    0.17    0.34    99.1 %        111        110                      
                                                                       0.04    0.23    0.17    0.34

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .      21                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                           564
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .      12                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .      15                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .       6                      

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon May  4 18:35:53.337 2009  to  Mon May  4 18:35:53.388 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

   2  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon May  4 18:41:55.256 2009  to  Mon May  4 18:41:55.309 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

   3  FAILED    GCS        command.setAGW                                                Mon May  4 18:48:20.939 2009  to  Mon May  4 18:48:46.414 2009   ( 25.48) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

   4  FAILED    GCS        command.getFocus                                              Mon May  4 18:52:58.024 2009  to  Mon May  4 18:53:01.048 2009   (  3.02) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

   5  FAILED    GCS        command.getFilter                                             Mon May  4 18:53:01.123 2009  to  Mon May  4 18:53:01.177 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

   6  FAILED    GCS        command.getFocus                                              Mon May  4 18:53:07.510 2009  to  Mon May  4 18:53:09.272 2009   (  1.76) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

   7  FAILED    GCS        command.getFilter                                             Mon May  4 18:53:09.348 2009  to  Mon May  4 18:53:09.402 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

   8  FAILED    GCS        command.setAGW                                                Mon May  4 18:54:54.469 2009  to  Mon May  4 18:54:54.525 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

   9  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 20:16:15.869 2009  to  Mon May  4 20:16:15.869 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  10  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 20:16:16.856 2009  to  Mon May  4 20:16:16.856 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  11  STARTUP   GCS        startup                                                       Mon May  4 20:16:24.170 2009  to  Mon May  4 20:16:24.170 2009   (  0.00) secs
                     left GCS subsystem started

  12  STARTUP   GCS        startup                                                       Mon May  4 20:24:30.176 2009  to  Mon May  4 20:24:30.176 2009   (  0.00) secs
                     left GCS subsystem started

  13  STARTUP   GCS        startup                                                       Mon May  4 20:26:31.390 2009  to  Mon May  4 20:26:31.390 2009   (  0.00) secs
                     left GCS subsystem started

  14  STARTUP   GCS        startup                                                       Mon May  4 20:32:38.750 2009  to  Mon May  4 20:32:38.750 2009   (  0.00) secs
                     left GCS subsystem started

  15  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 20:57:32.586 2009  to  Mon May  4 20:58:01.616 2009   ( 29.03) secs
                     guiding was not stable within 6 cycles

  16  FAILED    GCS        command.getFullWFImage                                        Mon May  4 21:15:07.845 2009  to  Mon May  4 21:15:47.194 2009   ( 39.35) secs
                     AzCam server timed out waiting for full CCD readout

  17  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 21:32:24.337 2009  to  Mon May  4 21:32:24.337 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  18  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 21:32:25.979 2009  to  Mon May  4 21:32:25.979 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  19  STARTUP   GCS        startup                                                       Mon May  4 21:32:31.192 2009  to  Mon May  4 21:32:31.192 2009   (  0.00) secs
                     left GCS subsystem started

  20  STARTUP   GCS        startup                                                       Mon May  4 21:46:48.417 2009  to  Mon May  4 21:46:48.417 2009   (  0.00) secs
                     left GCS subsystem started

  21  STARTUP   GCS        startup                                                       Mon May  4 21:50:58.633 2009  to  Mon May  4 21:50:58.633 2009   (  0.00) secs
                     left GCS subsystem started

  22  STARTUP   GCS        startup                                                       Mon May  4 22:19:12.798 2009  to  Mon May  4 22:19:12.798 2009   (  0.00) secs
                     left GCS subsystem started

  23  STARTUP   GCS        startup                                                       Mon May  4 22:22:35.927 2009  to  Mon May  4 22:22:35.927 2009   (  0.00) secs
                     left GCS subsystem started

  24  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon May  4 22:24:58.888 2009  to  Mon May  4 22:26:20.304 2009   ( 81.42) secs
                     timeout waiting to receive an image

  25  STARTUP   GCS        startup                                                       Mon May  4 22:27:50.213 2009  to  Mon May  4 22:27:50.213 2009   (  0.00) secs
                     left GCS subsystem started

  26  STARTUP   GCS        startup                                                       Mon May  4 22:45:07.591 2009  to  Mon May  4 22:45:07.591 2009   (  0.00) secs
                     left GCS subsystem started

  27  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 22:48:29.998 2009  to  Mon May  4 22:48:39.728 2009   (  9.73) secs
                     guiding was not stable within 6 cycles

  28  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 23:06:21.965 2009  to  Mon May  4 23:06:21.965 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  29  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 23:06:22.861 2009  to  Mon May  4 23:06:22.861 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  30  STARTUP   GCS        startup                                                       Mon May  4 23:06:27.042 2009  to  Mon May  4 23:06:27.042 2009   (  0.00) secs
                     left GCS subsystem started

  31  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 23:31:32.970 2009  to  Mon May  4 23:31:43.171 2009   ( 10.20) secs
                     timeout occured waiting for a guide image

  32  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 23:56:14.256 2009  to  Mon May  4 23:56:24.732 2009   ( 10.48) secs
                     timeout occured waiting for a guide image

  33  FAILED    GCS        interface.azcam.guider.readout                                Tue May  5 00:32:47.715 2009  to  Tue May  5 00:32:58.167 2009   ( 10.45) secs
                     timeout occured waiting for a guide image

  34  FAILED    GCS        command.setAGW                                                Tue May  5 00:58:12.090 2009  to  Tue May  5 00:58:37.954 2009   ( 25.86) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  35  FAILED    GCS        command.setAGW                                                Tue May  5 00:59:05.049 2009  to  Tue May  5 00:59:05.103 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

  36  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 00:59:36.149 2009  to  Tue May  5 00:59:38.006 2009   (  1.86) secs
                     AzCam server timed out waiting for full CCD readout

  37  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 00:59:58.342 2009  to  Tue May  5 01:00:00.194 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

  38  FAILED    GCS        command.setAGW                                                Tue May  5 01:40:22.692 2009  to  Tue May  5 01:40:22.740 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

  39  FAILED    GCS        command.setAGW                                                Tue May  5 01:40:28.893 2009  to  Tue May  5 01:42:08.941 2009   (100.05) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

  40  FAILED    GCS        command.setAGW                                                Tue May  5 01:42:10.499 2009  to  Tue May  5 01:42:10.554 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

  41  FAILED    GCS        command.setAGW                                                Tue May  5 01:43:45.885 2009  to  Tue May  5 01:43:54.693 2009   (  8.81) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

  42  FAILED    GCS        command.setAGW                                                Tue May  5 01:45:25.929 2009  to  Tue May  5 01:45:25.929 2009   (  0.00) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

  43  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:00:26.251 2009  to  Tue May  5 02:01:05.566 2009   ( 39.31) secs
                     AzCam server timed out waiting for full CCD readout

  44  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:01:38.156 2009  to  Tue May  5 02:01:38.447 2009   (  0.29) secs
                     could not set exposure time with AzCam server

  45  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:01:38.591 2009  to  Tue May  5 02:02:17.866 2009   ( 39.27) secs
                     AzCam server timed out waiting for full CCD readout

  46  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:02:17.960 2009  to  Tue May  5 02:02:18.218 2009   (  0.26) secs
                     could not set exposure time with AzCam server

  47  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:02:32.590 2009  to  Tue May  5 02:02:32.672 2009   (  0.08) secs
                     could not set exposure time with AzCam server

  48  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:02:32.825 2009  to  Tue May  5 02:03:12.142 2009   ( 39.32) secs
                     AzCam server timed out waiting for full CCD readout

  49  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:03:12.223 2009  to  Tue May  5 02:03:14.936 2009   (  2.71) secs
                     could not set exposure time with AzCam server

  50  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:14.658 2009  to  Tue May  5 02:04:14.931 2009   (  0.27) secs
                     could not set exposure time with AzCam server

  51  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:04:15.086 2009  to  Tue May  5 02:04:15.134 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

  52  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:15.217 2009  to  Tue May  5 02:04:15.269 2009   (  0.05) secs
                     could not set exposure time with AzCam server

  53  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:29.181 2009  to  Tue May  5 02:04:29.234 2009   (  0.05) secs
                     could not set exposure time with AzCam server

  54  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:04:29.381 2009  to  Tue May  5 02:04:29.433 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

  55  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:29.518 2009  to  Tue May  5 02:05:01.883 2009   ( 32.36) secs
                     could not set exposure time with AzCam server

  56  FAILED    GCS        command.setAGW                                                Tue May  5 02:05:09.612 2009  to  Tue May  5 02:05:09.667 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

  57  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:05:59.332 2009  to  Tue May  5 02:05:59.400 2009   (  0.07) secs
                     could not set exposure time with AzCam server

  58  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:05:59.585 2009  to  Tue May  5 02:06:38.870 2009   ( 39.28) secs
                     AzCam server timed out waiting for full CCD readout

  59  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:07:00.968 2009  to  Tue May  5 02:07:01.239 2009   (  0.27) secs
                     could not set exposure time with AzCam server

  60  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:07:01.499 2009  to  Tue May  5 02:07:04.762 2009   (  3.26) secs
                     AzCam server timed out waiting for full CCD readout

  61  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:07:04.870 2009  to  Tue May  5 02:07:11.898 2009   (  7.03) secs
                     could not set exposure time with AzCam server

  62  FAILED    GCS        command.setAGW                                                Tue May  5 02:08:27.885 2009  to  Tue May  5 02:08:27.973 2009   (  0.09) secs
                     COULD NOT change active AGW configuration to junk

  63  FAILED    GCS        command.getFocus                                              Tue May  5 02:09:02.647 2009  to  Tue May  5 02:09:02.924 2009   (  0.28) secs
                    

  64  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:09:15.998 2009  to  Tue May  5 02:09:16.143 2009   (  0.14) secs
                     could not set exposure time with AzCam server

  65  FAILED    GCS        command.setAGW                                                Tue May  5 02:10:16.089 2009  to  Tue May  5 02:10:16.143 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

  66  FAILED    GCS        command.setAGW                                                Tue May  5 02:10:21.211 2009  to  Tue May  5 02:10:25.363 2009   (  4.15) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

  67  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:11:02.317 2009  to  Tue May  5 02:11:02.317 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  68  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:11:03.210 2009  to  Tue May  5 02:11:03.210 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  69  STARTUP   GCS        startup                                                       Tue May  5 02:11:11.504 2009  to  Tue May  5 02:11:11.504 2009   (  0.00) secs
                     left GCS subsystem started

  70  FAILED    GCS        command.getFocus                                              Tue May  5 02:12:11.325 2009  to  Tue May  5 02:12:11.682 2009   (  0.36) secs
                    

  71  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 02:13:21.349 2009  to  Tue May  5 02:13:28.026 2009   (  6.68) secs
                     AzCam server timed out waiting for full CCD readout

  72  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:13:23.657 2009  to  Tue May  5 02:13:26.911 2009   (  3.25) secs
                     AzCam server timed out waiting for full CCD readout

  73  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:18:55.506 2009  to  Tue May  5 02:18:55.570 2009   (  0.06) secs
                     AzCam server timed out waiting for full CCD readout

  74  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:19:13.625 2009  to  Tue May  5 02:19:13.625 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  75  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:19:14.895 2009  to  Tue May  5 02:19:14.895 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  76  STARTUP   GCS        startup                                                       Tue May  5 02:19:23.182 2009  to  Tue May  5 02:19:23.182 2009   (  0.00) secs
                     left GCS subsystem started

  77  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:26:10.456 2009  to  Tue May  5 02:26:10.456 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  78  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:26:11.231 2009  to  Tue May  5 02:26:11.231 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  79  STARTUP   GCS        startup                                                       Tue May  5 02:26:19.094 2009  to  Tue May  5 02:26:19.094 2009   (  0.00) secs
                     left GCS subsystem started

  80  FAILED    GCS        command.setAGW                                                Tue May  5 03:53:39.706 2009  to  Tue May  5 03:53:39.761 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

  81  FAILED    GCS        command.setAGW                                                Tue May  5 03:55:26.888 2009  to  Tue May  5 03:55:54.830 2009   ( 27.94) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_L.cfg

  82  FAILED    GCS        command.setAGW                                                Tue May  5 04:08:08.839 2009  to  Tue May  5 04:08:35.576 2009   ( 26.74) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                 14           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      60                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      47                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      60                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      31                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      36                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .      60                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     111                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    2530                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     830                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  8           
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            76
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      34                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      30                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       7                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      31                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      47                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                  2           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.515 2009  to  Mon May  4 18:33:39.515 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053514594e+09 but t0 of the AZ target polynomial is 4.748169907730000e+09. Difference= 3.414578459453583e+04 seq=534477

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.516 2009  to  Mon May  4 18:33:39.516 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053515789e+09 but t0 of the EL target polynomial is 4.748169907730000e+09. Difference= 3.414578578948975e+04 seq=534477

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.517 2009  to  Mon May  4 18:33:39.517 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053473617e+09 but t0 of the LDG target polynomial is 4.748169907730000e+09. Difference= 3.414574361705780e+04 seq=534477

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:40:31.353 2009  to  Mon May  4 18:40:31.353 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:40:31.353 2009  to  Mon May  4 18:40:31.353 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 18:40:32.414 2009  to  Mon May  4 18:40:32.414 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.745 2009  to  Mon May  4 18:41:29.745 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523744061e+09 but t0 of the AZ target polynomial is 4.748204464270000e+09. Difference= 5.947406101226807e+01 seq=123489

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.746 2009  to  Mon May  4 18:41:29.746 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523745769e+09 but t0 of the EL target polynomial is 4.748204464270000e+09. Difference= 5.947576808929443e+01 seq=123489

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.748 2009  to  Mon May  4 18:41:29.748 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523671175e+09 but t0 of the LDG target polynomial is 4.748204464270000e+09. Difference= 5.940117454528809e+01 seq=123489

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:45:11.985 2009  to  Mon May  4 18:45:11.985 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:45:12.008 2009  to  Mon May  4 18:45:12.008 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  12  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 18:45:12.979 2009  to  Mon May  4 18:45:12.979 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.200 2009  to  Mon May  4 19:29:29.200 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403198875e+09 but t0 of the AZ target polynomial is 4.748204744948999e+09. Difference= 2.658249876022339e+03 seq=5386

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.201 2009  to  Mon May  4 19:29:29.201 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403199766e+09 but t0 of the EL target polynomial is 4.748204744948999e+09. Difference= 2.658250766754150e+03 seq=5386

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.202 2009  to  Mon May  4 19:29:29.202 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403156416e+09 but t0 of the LDG target polynomial is 4.748204744948999e+09. Difference= 2.658207416534424e+03 seq=5386

  16  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue May  5 00:38:03.079 2009  to  Tue May  5 00:38:03.079 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 02:28:38.442 2009  to  Tue May  5 02:28:38.442 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 02:28:38.467 2009  to  Tue May  5 02:28:38.467 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  19  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 02:28:39.406 2009  to  Tue May  5 02:28:39.406 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  20  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue May  5 02:28:42.948 2009  to  Tue May  5 02:28:42.948 2009   (  0.00) secs
                     LDG bad poly no. 16605: t0 is 5.521651e+00 seconds in the past!

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.953 2009  to  Tue May  5 02:28:42.953 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556952669e+09 but t0 of the AZ target polynomial is 4.748232551426000e+09. Difference= 5.526669502258301e+00 seq=561345

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.955 2009  to  Tue May  5 02:28:42.955 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556953327e+09 but t0 of the EL target polynomial is 4.748232551426000e+09. Difference= 5.527327537536621e+00 seq=561345

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.956 2009  to  Tue May  5 02:28:42.956 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556928873e+09 but t0 of the LDG target polynomial is 4.748232551376000e+09. Difference= 5.552872657775879e+00 seq=561344

  24  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue May  5 03:33:47.061 2009  to  Tue May  5 03:33:47.061 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 04:03:22.335 2009  to  Tue May  5 04:03:22.335 2009   (  0.00) secs
                     MJDsec from DSP is 4.748238236251384e+09 but t0 of the LFBG target polynomial is 4.748117239571000e+09. Difference= 1.209966803836823e+05 seq=4681501

  26  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:03:24.292 2009  to  Tue May  5 04:03:24.292 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue May  5 04:04:28.905 2009  to  Tue May  5 04:04:28.905 2009   (  0.00) secs
                     LDG bad poly no. 16606: t0 is 6.662779e+01 seconds in the past!

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May  5 04:04:28.902 2009  to  Tue May  5 04:04:28.902 2009   (  0.00) secs
                     AZ bad poly no. 3: BAD Poly:t0 is -6.662529e+01 seconds in the past!

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May  5 04:04:28.903 2009  to  Tue May  5 04:04:28.903 2009   (  0.00) secs
                     EL bad poly no. 159347: BAD Poly:t0 is -6.662644e+01 seconds in the past!

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 04:04:28.953 2009  to  Tue May  5 04:04:28.953 2009   (  0.00) secs
                     MJDsec from DSP is 4.748238302899689e+09 but t0 of the LDG target polynomial is 4.748238236277000e+09. Difference= 6.662268829345703e+01 seq=674884

  31  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:04:30.857 2009  to  Tue May  5 04:04:30.857 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:06:07.084 2009  to  Tue May  5 04:06:07.084 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 04:06:46.500 2009  to  Tue May  5 04:06:46.500 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 04:06:46.530 2009  to  Tue May  5 04:06:46.530 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    0.32    2.71    2.18    3.27   100.0 %         32         32                      
                                                                       0.32    2.71    2.18    3.27
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    9.25   30.02   24.42   40.69   100.0 %          3          3                      
                                                                       9.25   30.02   24.42   40.69

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             3

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         30         30                      
                                                                       0.00    0.05    0.05    0.06
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.04    0.20   100.0 %       1454       1454                      
                                                                       0.01    0.05    0.04    0.20
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.39    2.07    1.11    2.68   100.0 %         22         22                        largeUpdate =    22
                                                                       0.39    2.07    1.11    2.68
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         10         10                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.06    0.05    0.11   100.0 %         26         26                      
                                                                       0.01    0.06    0.05    0.11
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.02    0.06    0.05    0.14   100.0 %         30         30                      
                                                                       0.02    0.06    0.05    0.14
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.03    0.07    0.05    0.15   100.0 %          7          7                      
                                                                       0.03    0.07    0.05    0.15
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.23    0.60    0.31    1.07   100.0 %         30         30                      
                                                                       0.23    0.60    0.31    1.07
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.03    0.03    0.00    0.11    28.6 %         14                    10           
                                                                       0.02    0.05    0.04    0.07

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  SHUTDOWN  PCS        shutdown                                                      Mon May  4 18:40:30.401 2009  to  Mon May  4 18:40:30.401 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.34b

   2  STARTUP   PCS        startup                                                       Mon May  4 18:40:40.570 2009  to  Mon May  4 18:40:40.570 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34a

   3  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:45:10.864 2009  to  Mon May  4 18:45:10.935 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   4  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:45:11.071 2009  to  Mon May  4 18:45:11.071 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   5  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.577 2009  to  Mon May  4 18:46:18.648 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  FAILED    PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.648 2009  to  Mon May  4 18:46:18.691 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.760 2009  to  Mon May  4 18:46:18.760 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   8  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:03:21.922 2009  to  Tue May  5 04:03:21.987 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   9  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:03:22.055 2009  to  Tue May  5 04:03:22.167 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  10  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.599 2009  to  Tue May  5 04:04:28.666 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  11  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.666 2009  to  Tue May  5 04:04:28.709 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  12  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.775 2009  to  Tue May  5 04:04:28.775 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  13  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.733 2009  to  Tue May  5 04:06:04.798 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  14  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.798 2009  to  Tue May  5 04:06:04.842 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  15  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.911 2009  to  Tue May  5 04:06:04.911 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  16  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:45.374 2009  to  Tue May  5 04:06:45.447 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  17  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:45.555 2009  to  Tue May  5 04:06:45.555 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  18  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.022 2009  to  Tue May  5 04:09:44.090 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  19  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.090 2009  to  Tue May  5 04:09:44.134 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  20  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.204 2009  to  Tue May  5 04:09:44.204 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.02    2.06    2.05    2.16   100.0 %         90         90                      
                                                                       0.02    2.06    2.05    2.16
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.35    5.73    2.05   55.16   100.0 %        155        155                      
                                                                       7.35    5.73    2.05   55.16
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.03    0.06    0.05    0.16   100.0 %         15         15                      
                                                                       0.03    0.06    0.05    0.16

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       4                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             3
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      90                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  3           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 18:41:46.833 2009  to  Mon May  4 18:41:46.833 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Mon May  4 18:41:46.885 2009  to  Mon May  4 18:41:46.885 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.close                                             Mon May  4 20:25:16.433 2009  to  Mon May  4 20:25:16.433 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 20:25:16.380 2009  to  Mon May  4 20:25:16.380 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 22:48:24.166 2009  to  Mon May  4 22:48:24.166 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Mon May  4 22:48:24.218 2009  to  Mon May  4 22:48:24.218 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   7  FAILED    PMC        VxInterface.selectTimeout                                     Mon May  4 23:56:56.526 2009  to  Mon May  4 23:56:56.526 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   8  FAILED    PMC        VxInterface.packetReadError                                   Mon May  4 23:56:56.580 2009  to  Mon May  4 23:56:56.580 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   9  FAILED    PMC        thermal.badReceive                                            Mon May  4 23:56:56.633 2009  to  Mon May  4 23:56:56.633 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  10  FAILED    PMC        VxInterface.lengthError                                       Tue May  5 00:20:03.429 2009  to  Tue May  5 00:20:03.429 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Tue May  5 00:20:03.481 2009  to  Tue May  5 00:20:03.481 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.selectTimeout                                     Tue May  5 00:26:55.478 2009  to  Tue May  5 00:26:55.478 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  13  FAILED    PMC        VxInterface.packetReadError                                   Tue May  5 00:26:55.531 2009  to  Tue May  5 00:26:55.531 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  14  FAILED    PMC        thermal.badReceive                                            Tue May  5 00:26:55.584 2009  to  Tue May  5 00:26:55.584 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  15  FAILED    PMC        VxInterface.selectTimeout                                     Tue May  5 02:46:36.176 2009  to  Tue May  5 02:46:36.176 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  16  FAILED    PMC        VxInterface.packetReadError                                   Tue May  5 02:46:36.228 2009  to  Tue May  5 02:46:36.228 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  17  FAILED    PMC        thermal.badReceive                                            Tue May  5 02:46:36.280 2009  to  Tue May  5 02:46:36.280 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.09    6.73    2.71   14.79   100.0 %        110        110                      
                                                                       2.09    6.73    2.71   14.79
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.19    0.32    0.27    1.33   100.0 %         32         32                      
                                                                       0.19    0.32    0.27    1.33
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.21    0.24    0.05    0.61    78.6 %         14         11          3           
                                                                       0.21    0.19    0.05    0.61
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.09    6.85    2.82   14.90   100.0 %        110        110                      
                                                                       2.09    6.85    2.82   14.90
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.92    6.27    0.24   22.58   100.0 %        118        118                      
                                                                       2.92    6.27    0.24   22.58
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.35    5.87    2.18   55.30   100.0 %        155        155                      
                                                                       7.35    5.87    2.18   55.30
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          1          1                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.11    0.18    0.11    0.67   100.0 %         27         27                      
                                                                       0.11    0.18    0.11    0.67
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.06    0.10    0.06    0.22    50.0 %          6          3          3           
                                                                       0.08    0.13    0.08    0.22
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   25.58   25.58   25.58   100.0 %          1          1                      
                                                                       0.00   25.58   25.58   25.58
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    1.21    7.32    5.30    8.37   100.0 %          8          8                      
                                                                       1.21    7.32    5.30    8.37
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          8          8                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.06   100.0 %         32         32                      
                                                                       0.00    0.05    0.05    0.06
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .   23.61   26.85    3.30   55.41   100.0 %          4          4                      
                                                                      23.61   26.85    3.30   55.41
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.02    0.06    0.05    0.17   100.0 %        118        118                      
                                                                       0.02    0.06    0.05    0.17
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    0.33    2.84    2.31    3.40   100.0 %         32         32                      
                                                                       0.33    2.84    2.31    3.40
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.02    0.06    0.05    0.19   100.0 %         32         32                      
                                                                       0.02    0.06    0.05    0.19
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.02    0.07    0.05    0.10   100.0 %          6          6                      
                                                                       0.02    0.07    0.05    0.10
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.01    0.06    0.05    0.08   100.0 %          6          6                      
                                                                       0.01    0.06    0.05    0.08

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                896           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:48:19.261 2009  to  Mon May  4 19:48:19.261 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.3035536e-04 -2.2776048e-03 -2.6476383e-04 -1.4469147e-02 -1.8545723e-01 1.6427755e-02

   2  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:48:19.516 2009  to  Mon May  4 19:48:19.516 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.3035536e-04 -2.2776048e-03 -2.6476383e-04 -1.4469147e-02 -1.8545723e-01 1.6427755e-02

   3  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:04.126 2009  to  Mon May  4 19:55:04.126 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.9762936e-04 -1.2922795e-03 -9.7382069e-04 -1.6708374e-03 -1.8394470e-01 1.1287451e-02

   4  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:04.382 2009  to  Mon May  4 19:55:04.382 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.9762936e-04 -1.2922795e-03 -9.7382069e-04 -1.6708374e-03 -1.8394470e-01 1.1287451e-02

   5  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:05.044 2009  to  Mon May  4 19:55:05.044 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.5790930e-04 -1.6683261e-03 -9.2983246e-04 -3.2066345e-02 -1.5163612e-01 1.3783216e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:05.299 2009  to  Mon May  4 19:55:05.299 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.5790930e-04 -1.6683261e-03 -9.2983246e-04 -3.2066345e-02 -1.5163612e-01 1.3783216e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:48.631 2009  to  Mon May  4 19:55:48.631 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

   8  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:48.886 2009  to  Mon May  4 19:55:48.886 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

   9  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:49.141 2009  to  Mon May  4 19:55:49.141 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

  10  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:57.494 2009  to  Mon May  4 19:55:57.494 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6053190e-04 -2.2610635e-03 -3.8480759e-04 4.5177460e-02 -1.5145111e-01 -1.8286943e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:57.750 2009  to  Mon May  4 19:55:57.750 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6053190e-04 -2.2610635e-03 -3.8480759e-04 4.5177460e-02 -1.5145111e-01 -1.8286943e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:20.876 2009  to  Mon May  4 19:56:20.876 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.9610605e-04 -1.6605766e-03 -7.4732304e-04 -9.8571777e-03 -1.5684128e-01 2.4122953e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:21.130 2009  to  Mon May  4 19:56:21.130 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.9610605e-04 -1.6605766e-03 -7.4732304e-04 -9.8571777e-03 -1.5684128e-01 2.4122953e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:31.100 2009  to  Mon May  4 19:56:31.100 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.4459782e-05 -2.5650780e-03 -7.4958801e-04 1.6380310e-02 -1.6805077e-01 -1.8302202e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:31.355 2009  to  Mon May  4 19:56:31.355 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.4459782e-05 -2.5650780e-03 -7.4958801e-04 1.6380310e-02 -1.6805077e-01 -1.8302202e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:39.892 2009  to  Mon May  4 19:56:39.892 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.2265654e-04 -2.5573284e-03 -5.6707859e-04 3.8589478e-02 -1.7325592e-01 -7.9624653e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:40.148 2009  to  Mon May  4 19:56:40.148 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.2265654e-04 -2.5573284e-03 -5.6707859e-04 3.8589478e-02 -1.7325592e-01 -7.9624653e-03

  18  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:00:45.294 2009  to  Mon May  4 20:00:45.294 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:00:45.549 2009  to  Mon May  4 20:00:45.549 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:03:53.201 2009  to  Mon May  4 20:03:53.201 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.8247318e-04 -2.5617094e-03 5.8734417e-04 2.2216797e-02 -1.7052460e-01 -7.3463917e-03

  21  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:03:53.456 2009  to  Mon May  4 20:03:53.456 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.8247318e-04 -2.5617094e-03 5.8734417e-04 2.2216797e-02 -1.7052460e-01 -7.3463917e-03

  22  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.384 2009  to  Mon May  4 20:04:17.384 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.639 2009  to  Mon May  4 20:04:17.639 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.894 2009  to  Mon May  4 20:04:17.894 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:24.842 2009  to  Mon May  4 20:04:24.842 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0270557e-04 -2.2661299e-03 4.0066242e-04 6.2484741e-03 -1.5351105e-01 3.2298565e-03

  26  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:03:22.391 2009  to  Tue May  5 04:03:22.774 2009   (  0.38) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

  27  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:03:22.443 2009  to  Tue May  5 04:03:22.500 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  28  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:04:28.997 2009  to  Tue May  5 04:04:29.507 2009   (  0.51) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

  29  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:04:29.050 2009  to  Tue May  5 04:04:29.140 2009   (  0.09) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  30  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:06:45.946 2009  to  Tue May  5 04:06:46.335 2009   (  0.39) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

  31  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:06:45.999 2009  to  Tue May  5 04:06:46.055 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 18:33:38.498 2009  to  Mon May  4 18:35:53.566 2009   (135.07) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.515 2009  to  Mon May  4 18:33:39.515 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053514594e+09 but t0 of the AZ target polynomial is 4.748169907730000e+09. Difference= 3.414578459453583e+04 seq=534477

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.516 2009  to  Mon May  4 18:33:39.516 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053515789e+09 but t0 of the EL target polynomial is 4.748169907730000e+09. Difference= 3.414578578948975e+04 seq=534477

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:33:39.517 2009  to  Mon May  4 18:33:39.517 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204053473617e+09 but t0 of the LDG target polynomial is 4.748169907730000e+09. Difference= 3.414574361705780e+04 seq=534477

   5  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon May  4 18:35:53.337 2009  to  Mon May  4 18:35:53.388 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

   6  SHUTDOWN  PCS        shutdown                                                      Mon May  4 18:40:30.401 2009  to  Mon May  4 18:40:30.401 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.34b

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:40:31.353 2009  to  Mon May  4 18:40:31.353 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:40:31.353 2009  to  Mon May  4 18:40:31.353 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   9  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 18:40:32.414 2009  to  Mon May  4 18:40:32.414 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  10  STARTUP   PCS        startup                                                       Mon May  4 18:40:40.570 2009  to  Mon May  4 18:40:40.570 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34a

  11  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 18:41:28.771 2009  to  Mon May  4 18:41:55.598 2009   ( 26.83) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.745 2009  to  Mon May  4 18:41:29.745 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523744061e+09 but t0 of the AZ target polynomial is 4.748204464270000e+09. Difference= 5.947406101226807e+01 seq=123489

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.746 2009  to  Mon May  4 18:41:29.746 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523745769e+09 but t0 of the EL target polynomial is 4.748204464270000e+09. Difference= 5.947576808929443e+01 seq=123489

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 18:41:29.748 2009  to  Mon May  4 18:41:29.748 2009   (  0.00) secs
                     MJDsec from DSP is 4.748204523671175e+09 but t0 of the LDG target polynomial is 4.748204464270000e+09. Difference= 5.940117454528809e+01 seq=123489

  15  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 18:41:46.833 2009  to  Mon May  4 18:41:46.833 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Mon May  4 18:41:46.885 2009  to  Mon May  4 18:41:46.885 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon May  4 18:41:55.256 2009  to  Mon May  4 18:41:55.309 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

  18  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:45:10.864 2009  to  Mon May  4 18:45:10.935 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  19  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:45:11.071 2009  to  Mon May  4 18:45:11.071 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:45:11.985 2009  to  Mon May  4 18:45:11.985 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 18:45:12.008 2009  to  Mon May  4 18:45:12.008 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  22  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 18:45:12.979 2009  to  Mon May  4 18:45:12.979 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  23  FAILED    IIF GUI    IIFCommand.authorize                                          Mon May  4 18:46:18.508 2009  to  Mon May  4 18:46:19.709 2009   (  1.20) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  24  FAILED    IIF GUI    IIFCommand.authorize                                          Mon May  4 18:46:18.513 2009  to  Mon May  4 18:46:19.095 2009   (  0.58) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  25  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.577 2009  to  Mon May  4 18:46:18.648 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  26  FAILED    PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.648 2009  to  Mon May  4 18:46:18.691 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  27  SEQERROR  PCS        telescope.command.stopTracking                                Mon May  4 18:46:18.760 2009  to  Mon May  4 18:46:18.760 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  28  FAILED    GCS        command.setAGW                                                Mon May  4 18:48:20.939 2009  to  Mon May  4 18:48:46.414 2009   ( 25.48) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  29  FAILED    GCS        command.getFocus                                              Mon May  4 18:52:58.024 2009  to  Mon May  4 18:53:01.048 2009   (  3.02) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

  30  FAILED    GCS        command.getFilter                                             Mon May  4 18:53:01.123 2009  to  Mon May  4 18:53:01.177 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

  31  FAILED    GCS        command.getFocus                                              Mon May  4 18:53:07.510 2009  to  Mon May  4 18:53:09.272 2009   (  1.76) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

  32  FAILED    GCS        command.getFilter                                             Mon May  4 18:53:09.348 2009  to  Mon May  4 18:53:09.402 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

  33  FAILED    GCS        command.setAGW                                                Mon May  4 18:54:54.469 2009  to  Mon May  4 18:54:54.525 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.200 2009  to  Mon May  4 19:29:29.200 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403198875e+09 but t0 of the AZ target polynomial is 4.748204744948999e+09. Difference= 2.658249876022339e+03 seq=5386

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.201 2009  to  Mon May  4 19:29:29.201 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403199766e+09 but t0 of the EL target polynomial is 4.748204744948999e+09. Difference= 2.658250766754150e+03 seq=5386

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 19:29:29.202 2009  to  Mon May  4 19:29:29.202 2009   (  0.00) secs
                     MJDsec from DSP is 4.748207403156416e+09 but t0 of the LDG target polynomial is 4.748204744948999e+09. Difference= 2.658207416534424e+03 seq=5386

  37  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:48:19.261 2009  to  Mon May  4 19:48:19.261 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.3035536e-04 -2.2776048e-03 -2.6476383e-04 -1.4469147e-02 -1.8545723e-01 1.6427755e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:48:19.516 2009  to  Mon May  4 19:48:19.516 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.3035536e-04 -2.2776048e-03 -2.6476383e-04 -1.4469147e-02 -1.8545723e-01 1.6427755e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:04.126 2009  to  Mon May  4 19:55:04.126 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.9762936e-04 -1.2922795e-03 -9.7382069e-04 -1.6708374e-03 -1.8394470e-01 1.1287451e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:04.382 2009  to  Mon May  4 19:55:04.382 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.9762936e-04 -1.2922795e-03 -9.7382069e-04 -1.6708374e-03 -1.8394470e-01 1.1287451e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:05.044 2009  to  Mon May  4 19:55:05.044 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.5790930e-04 -1.6683261e-03 -9.2983246e-04 -3.2066345e-02 -1.5163612e-01 1.3783216e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:05.299 2009  to  Mon May  4 19:55:05.299 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.5790930e-04 -1.6683261e-03 -9.2983246e-04 -3.2066345e-02 -1.5163612e-01 1.3783216e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:48.631 2009  to  Mon May  4 19:55:48.631 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

  44  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:48.886 2009  to  Mon May  4 19:55:48.886 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

  45  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:49.141 2009  to  Mon May  4 19:55:49.141 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -6.3550472e-04 -9.9601457e-04 -7.9154968e-04 4.9171448e-03 -1.6213989e-01 9.6297264e-04

  46  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:57.494 2009  to  Mon May  4 19:55:57.494 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6053190e-04 -2.2610635e-03 -3.8480759e-04 4.5177460e-02 -1.5145111e-01 -1.8286943e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:55:57.750 2009  to  Mon May  4 19:55:57.750 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6053190e-04 -2.2610635e-03 -3.8480759e-04 4.5177460e-02 -1.5145111e-01 -1.8286943e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:20.876 2009  to  Mon May  4 19:56:20.876 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.9610605e-04 -1.6605766e-03 -7.4732304e-04 -9.8571777e-03 -1.5684128e-01 2.4122953e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:21.130 2009  to  Mon May  4 19:56:21.130 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -5.9610605e-04 -1.6605766e-03 -7.4732304e-04 -9.8571777e-03 -1.5684128e-01 2.4122953e-02

  50  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:31.100 2009  to  Mon May  4 19:56:31.100 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.4459782e-05 -2.5650780e-03 -7.4958801e-04 1.6380310e-02 -1.6805077e-01 -1.8302202e-02

  51  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:31.355 2009  to  Mon May  4 19:56:31.355 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.4459782e-05 -2.5650780e-03 -7.4958801e-04 1.6380310e-02 -1.6805077e-01 -1.8302202e-02

  52  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:39.892 2009  to  Mon May  4 19:56:39.892 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.2265654e-04 -2.5573284e-03 -5.6707859e-04 3.8589478e-02 -1.7325592e-01 -7.9624653e-03

  53  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 19:56:40.148 2009  to  Mon May  4 19:56:40.148 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -4.2265654e-04 -2.5573284e-03 -5.6707859e-04 3.8589478e-02 -1.7325592e-01 -7.9624653e-03

  54  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:00:45.294 2009  to  Mon May  4 20:00:45.294 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:00:45.549 2009  to  Mon May  4 20:00:45.549 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:03:53.201 2009  to  Mon May  4 20:03:53.201 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.8247318e-04 -2.5617094e-03 5.8734417e-04 2.2216797e-02 -1.7052460e-01 -7.3463917e-03

  57  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:03:53.456 2009  to  Mon May  4 20:03:53.456 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 6.8247318e-04 -2.5617094e-03 5.8734417e-04 2.2216797e-02 -1.7052460e-01 -7.3463917e-03

  58  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.384 2009  to  Mon May  4 20:04:17.384 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  59  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.639 2009  to  Mon May  4 20:04:17.639 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  60  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:17.894 2009  to  Mon May  4 20:04:17.894 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 1.6087294e-04 -2.2669942e-03 3.1709671e-05 -1.6296387e-02 -1.5831757e-01 2.4122953e-02

  61  FAILED    PSF        primaryMirror.positionError                                   Mon May  4 20:04:24.842 2009  to  Mon May  4 20:04:24.842 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 5.0270557e-04 -2.2661299e-03 4.0066242e-04 6.2484741e-03 -1.5351105e-01 3.2298565e-03

  62  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 20:16:15.869 2009  to  Mon May  4 20:16:15.869 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  63  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 20:16:16.856 2009  to  Mon May  4 20:16:16.856 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  64  STARTUP   GCS        startup                                                       Mon May  4 20:16:24.170 2009  to  Mon May  4 20:16:24.170 2009   (  0.00) secs
                     left GCS subsystem started

  65  STARTUP   GCS        startup                                                       Mon May  4 20:24:30.176 2009  to  Mon May  4 20:24:30.176 2009   (  0.00) secs
                     left GCS subsystem started

  66  FAILED    PMC        VxInterface.close                                             Mon May  4 20:25:16.433 2009  to  Mon May  4 20:25:16.433 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  67  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 20:25:16.380 2009  to  Mon May  4 20:25:16.380 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  68  STARTUP   GCS        startup                                                       Mon May  4 20:26:31.390 2009  to  Mon May  4 20:26:31.390 2009   (  0.00) secs
                     left GCS subsystem started

  69  STARTUP   GCS        startup                                                       Mon May  4 20:32:38.750 2009  to  Mon May  4 20:32:38.750 2009   (  0.00) secs
                     left GCS subsystem started

  70  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 20:57:13.610 2009  to  Mon May  4 20:58:02.119 2009   ( 48.51) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 2100 ms at the given guide rate, estimated counts are 56
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 2100 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  71  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 20:57:32.586 2009  to  Mon May  4 20:58:01.616 2009   ( 29.03) secs
                     guiding was not stable within 6 cycles

  72  FAILED    GCS        command.getFullWFImage                                        Mon May  4 21:15:07.845 2009  to  Mon May  4 21:15:47.194 2009   ( 39.35) secs
                     AzCam server timed out waiting for full CCD readout

  73  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 21:32:24.337 2009  to  Mon May  4 21:32:24.337 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  74  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 21:32:25.979 2009  to  Mon May  4 21:32:25.979 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  75  STARTUP   GCS        startup                                                       Mon May  4 21:32:31.192 2009  to  Mon May  4 21:32:31.192 2009   (  0.00) secs
                     left GCS subsystem started

  76  STARTUP   GCS        startup                                                       Mon May  4 21:46:48.417 2009  to  Mon May  4 21:46:48.417 2009   (  0.00) secs
                     left GCS subsystem started

  77  STARTUP   GCS        startup                                                       Mon May  4 21:50:58.633 2009  to  Mon May  4 21:50:58.633 2009   (  0.00) secs
                     left GCS subsystem started

  78  STARTUP   GCS        startup                                                       Mon May  4 22:19:12.798 2009  to  Mon May  4 22:19:12.798 2009   (  0.00) secs
                     left GCS subsystem started

  79  STARTUP   GCS        startup                                                       Mon May  4 22:22:35.927 2009  to  Mon May  4 22:22:35.927 2009   (  0.00) secs
                     left GCS subsystem started

  80  FAILED    GCS        interface.azcam.wfsc.readout                                  Mon May  4 22:24:58.888 2009  to  Mon May  4 22:26:20.304 2009   ( 81.42) secs
                     timeout waiting to receive an image

  81  STARTUP   GCS        startup                                                       Mon May  4 22:27:50.213 2009  to  Mon May  4 22:27:50.213 2009   (  0.00) secs
                     left GCS subsystem started

  82  STARTUP   GCS        startup                                                       Mon May  4 22:45:07.591 2009  to  Mon May  4 22:45:07.591 2009   (  0.00) secs
                     left GCS subsystem started

  83  FAILED    IIF        command.preset.(ACTIVE)                                       Mon May  4 22:48:07.628 2009  to  Mon May  4 22:48:40.061 2009   ( 32.43) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  84  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 22:48:24.166 2009  to  Mon May  4 22:48:24.166 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  85  FAILED    PMC        VxInterface.close                                             Mon May  4 22:48:24.218 2009  to  Mon May  4 22:48:24.218 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  86  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 22:48:29.998 2009  to  Mon May  4 22:48:39.728 2009   (  9.73) secs
                     guiding was not stable within 6 cycles

  87  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 23:06:21.965 2009  to  Mon May  4 23:06:21.965 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  88  SHUTDOWN  GCS        command.shutdown                                              Mon May  4 23:06:22.861 2009  to  Mon May  4 23:06:22.861 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  89  STARTUP   GCS        startup                                                       Mon May  4 23:06:27.042 2009  to  Mon May  4 23:06:27.042 2009   (  0.00) secs
                     left GCS subsystem started

  90  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 23:31:32.970 2009  to  Mon May  4 23:31:43.171 2009   ( 10.20) secs
                     timeout occured waiting for a guide image

  91  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 23:56:14.256 2009  to  Mon May  4 23:56:24.732 2009   ( 10.48) secs
                     timeout occured waiting for a guide image

  92  FAILED    PMC        VxInterface.selectTimeout                                     Mon May  4 23:56:56.526 2009  to  Mon May  4 23:56:56.526 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  93  FAILED    PMC        VxInterface.packetReadError                                   Mon May  4 23:56:56.580 2009  to  Mon May  4 23:56:56.580 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  94  FAILED    PMC        thermal.badReceive                                            Mon May  4 23:56:56.633 2009  to  Mon May  4 23:56:56.633 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  95  FAILED    PMC        VxInterface.lengthError                                       Tue May  5 00:20:03.429 2009  to  Tue May  5 00:20:03.429 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  96  FAILED    PMC        VxInterface.close                                             Tue May  5 00:20:03.481 2009  to  Tue May  5 00:20:03.481 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  97  FAILED    PMC        VxInterface.selectTimeout                                     Tue May  5 00:26:55.478 2009  to  Tue May  5 00:26:55.478 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  98  FAILED    PMC        VxInterface.packetReadError                                   Tue May  5 00:26:55.531 2009  to  Tue May  5 00:26:55.531 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  99  FAILED    PMC        thermal.badReceive                                            Tue May  5 00:26:55.584 2009  to  Tue May  5 00:26:55.584 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 100  FAILED    GCS        interface.azcam.guider.readout                                Tue May  5 00:32:47.715 2009  to  Tue May  5 00:32:58.167 2009   ( 10.45) secs
                     timeout occured waiting for a guide image

 101  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue May  5 00:38:03.079 2009  to  Tue May  5 00:38:03.079 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 102  FAILED    GCS        command.setAGW                                                Tue May  5 00:58:12.090 2009  to  Tue May  5 00:58:37.954 2009   ( 25.86) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

 103  FAILED    GCS        command.setAGW                                                Tue May  5 00:59:05.049 2009  to  Tue May  5 00:59:05.103 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

 104  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 00:59:36.149 2009  to  Tue May  5 00:59:38.006 2009   (  1.86) secs
                     AzCam server timed out waiting for full CCD readout

 105  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 00:59:58.342 2009  to  Tue May  5 01:00:00.194 2009   (  1.85) secs
                     AzCam server timed out waiting for full CCD readout

 106  FAILED    GCS        command.setAGW                                                Tue May  5 01:40:22.692 2009  to  Tue May  5 01:40:22.740 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

 107  FAILED    GCS        command.setAGW                                                Tue May  5 01:40:28.893 2009  to  Tue May  5 01:42:08.941 2009   (100.05) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

 108  FAILED    GCS        command.setAGW                                                Tue May  5 01:42:10.499 2009  to  Tue May  5 01:42:10.554 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

 109  FAILED    GCS        command.setAGW                                                Tue May  5 01:43:45.885 2009  to  Tue May  5 01:43:54.693 2009   (  8.81) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

 110  FAILED    GCS        command.setAGW                                                Tue May  5 01:45:25.929 2009  to  Tue May  5 01:45:25.929 2009   (  0.00) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

 111  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:00:26.251 2009  to  Tue May  5 02:01:05.566 2009   ( 39.31) secs
                     AzCam server timed out waiting for full CCD readout

 112  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:01:38.156 2009  to  Tue May  5 02:01:38.447 2009   (  0.29) secs
                     could not set exposure time with AzCam server

 113  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:01:38.591 2009  to  Tue May  5 02:02:17.866 2009   ( 39.27) secs
                     AzCam server timed out waiting for full CCD readout

 114  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:02:17.960 2009  to  Tue May  5 02:02:18.218 2009   (  0.26) secs
                     could not set exposure time with AzCam server

 115  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:02:32.590 2009  to  Tue May  5 02:02:32.672 2009   (  0.08) secs
                     could not set exposure time with AzCam server

 116  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:02:32.825 2009  to  Tue May  5 02:03:12.142 2009   ( 39.32) secs
                     AzCam server timed out waiting for full CCD readout

 117  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:03:12.223 2009  to  Tue May  5 02:03:14.936 2009   (  2.71) secs
                     could not set exposure time with AzCam server

 118  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:14.658 2009  to  Tue May  5 02:04:14.931 2009   (  0.27) secs
                     could not set exposure time with AzCam server

 119  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:04:15.086 2009  to  Tue May  5 02:04:15.134 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

 120  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:15.217 2009  to  Tue May  5 02:04:15.269 2009   (  0.05) secs
                     could not set exposure time with AzCam server

 121  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:29.181 2009  to  Tue May  5 02:04:29.234 2009   (  0.05) secs
                     could not set exposure time with AzCam server

 122  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:04:29.381 2009  to  Tue May  5 02:04:29.433 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

 123  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:04:29.518 2009  to  Tue May  5 02:05:01.883 2009   ( 32.36) secs
                     could not set exposure time with AzCam server

 124  FAILED    GCS        command.setAGW                                                Tue May  5 02:05:09.612 2009  to  Tue May  5 02:05:09.667 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

 125  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:05:59.332 2009  to  Tue May  5 02:05:59.400 2009   (  0.07) secs
                     could not set exposure time with AzCam server

 126  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:05:59.585 2009  to  Tue May  5 02:06:38.870 2009   ( 39.28) secs
                     AzCam server timed out waiting for full CCD readout

 127  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:07:00.968 2009  to  Tue May  5 02:07:01.239 2009   (  0.27) secs
                     could not set exposure time with AzCam server

 128  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:07:01.499 2009  to  Tue May  5 02:07:04.762 2009   (  3.26) secs
                     AzCam server timed out waiting for full CCD readout

 129  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:07:04.870 2009  to  Tue May  5 02:07:11.898 2009   (  7.03) secs
                     could not set exposure time with AzCam server

 130  FAILED    GCS        command.setAGW                                                Tue May  5 02:08:27.885 2009  to  Tue May  5 02:08:27.973 2009   (  0.09) secs
                     COULD NOT change active AGW configuration to junk

 131  FAILED    GCS        command.getFocus                                              Tue May  5 02:09:02.647 2009  to  Tue May  5 02:09:02.924 2009   (  0.28) secs
                    

 132  FAILED    GCS        command.setWFCamExposureTime                                  Tue May  5 02:09:15.998 2009  to  Tue May  5 02:09:16.143 2009   (  0.14) secs
                     could not set exposure time with AzCam server

 133  FAILED    GCS        command.setAGW                                                Tue May  5 02:10:16.089 2009  to  Tue May  5 02:10:16.143 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

 134  FAILED    GCS        command.setAGW                                                Tue May  5 02:10:21.211 2009  to  Tue May  5 02:10:25.363 2009   (  4.15) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_DG_L.cfg

 135  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:11:02.317 2009  to  Tue May  5 02:11:02.317 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 136  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:11:03.210 2009  to  Tue May  5 02:11:03.210 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 137  STARTUP   GCS        startup                                                       Tue May  5 02:11:11.504 2009  to  Tue May  5 02:11:11.504 2009   (  0.00) secs
                     left GCS subsystem started

 138  FAILED    GCS        command.getFocus                                              Tue May  5 02:12:11.325 2009  to  Tue May  5 02:12:11.682 2009   (  0.36) secs
                    

 139  FAILED    GCS        command.getFullGuideImage                                     Tue May  5 02:13:21.349 2009  to  Tue May  5 02:13:28.026 2009   (  6.68) secs
                     AzCam server timed out waiting for full CCD readout

 140  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:13:23.657 2009  to  Tue May  5 02:13:26.911 2009   (  3.25) secs
                     AzCam server timed out waiting for full CCD readout

 141  FAILED    GCS        command.getFullWFImage                                        Tue May  5 02:18:55.506 2009  to  Tue May  5 02:18:55.570 2009   (  0.06) secs
                     AzCam server timed out waiting for full CCD readout

 142  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:19:13.625 2009  to  Tue May  5 02:19:13.625 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 143  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:19:14.895 2009  to  Tue May  5 02:19:14.895 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 144  STARTUP   GCS        startup                                                       Tue May  5 02:19:23.182 2009  to  Tue May  5 02:19:23.182 2009   (  0.00) secs
                     left GCS subsystem started

 145  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:26:10.456 2009  to  Tue May  5 02:26:10.456 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 146  SHUTDOWN  GCS        command.shutdown                                              Tue May  5 02:26:11.231 2009  to  Tue May  5 02:26:11.231 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 147  STARTUP   GCS        startup                                                       Tue May  5 02:26:19.094 2009  to  Tue May  5 02:26:19.094 2009   (  0.00) secs
                     left GCS subsystem started

 148  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 02:28:38.442 2009  to  Tue May  5 02:28:38.442 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 149  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 02:28:38.467 2009  to  Tue May  5 02:28:38.467 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 150  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 02:28:39.406 2009  to  Tue May  5 02:28:39.406 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 151  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue May  5 02:28:42.948 2009  to  Tue May  5 02:28:42.948 2009   (  0.00) secs
                     LDG bad poly no. 16605: t0 is 5.521651e+00 seconds in the past!

 152  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.953 2009  to  Tue May  5 02:28:42.953 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556952669e+09 but t0 of the AZ target polynomial is 4.748232551426000e+09. Difference= 5.526669502258301e+00 seq=561345

 153  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.955 2009  to  Tue May  5 02:28:42.955 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556953327e+09 but t0 of the EL target polynomial is 4.748232551426000e+09. Difference= 5.527327537536621e+00 seq=561345

 154  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 02:28:42.956 2009  to  Tue May  5 02:28:42.956 2009   (  0.00) secs
                     MJDsec from DSP is 4.748232556928873e+09 but t0 of the LDG target polynomial is 4.748232551376000e+09. Difference= 5.552872657775879e+00 seq=561344

 155  FAILED    PMC        VxInterface.selectTimeout                                     Tue May  5 02:46:36.176 2009  to  Tue May  5 02:46:36.176 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 156  FAILED    PMC        VxInterface.packetReadError                                   Tue May  5 02:46:36.228 2009  to  Tue May  5 02:46:36.228 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 157  FAILED    PMC        thermal.badReceive                                            Tue May  5 02:46:36.280 2009  to  Tue May  5 02:46:36.280 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 158  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue May  5 03:33:47.061 2009  to  Tue May  5 03:33:47.061 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 159  FAILED    GCS        command.setAGW                                                Tue May  5 03:53:39.706 2009  to  Tue May  5 03:53:39.761 2009   (  0.06) secs
                     COULD NOT change active AGW configuration to junk

 160  FAILED    GCS        command.setAGW                                                Tue May  5 03:55:26.888 2009  to  Tue May  5 03:55:54.830 2009   ( 27.94) secs
                     COULD NOT change active AGW configuration to AIP_IRTC_L.cfg

 161  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:03:21.922 2009  to  Tue May  5 04:03:21.987 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 162  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:03:21.855 2009  to  Tue May  5 04:03:48.040 2009   ( 26.18) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

 163  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:03:21.861 2009  to  Tue May  5 04:03:22.342 2009   (  0.48) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 164  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:03:22.055 2009  to  Tue May  5 04:03:22.167 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 165  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 04:03:22.335 2009  to  Tue May  5 04:03:22.335 2009   (  0.00) secs
                     MJDsec from DSP is 4.748238236251384e+09 but t0 of the LFBG target polynomial is 4.748117239571000e+09. Difference= 1.209966803836823e+05 seq=4681501

 166  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:03:22.391 2009  to  Tue May  5 04:03:22.774 2009   (  0.38) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCF, focal station bentGregorianFront

 167  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:03:22.443 2009  to  Tue May  5 04:03:22.500 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 168  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:03:24.292 2009  to  Tue May  5 04:03:24.292 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 169  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:04:28.532 2009  to  Tue May  5 04:04:29.779 2009   (  1.25) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

 170  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:04:28.538 2009  to  Tue May  5 04:04:29.047 2009   (  0.51) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 171  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.599 2009  to  Tue May  5 04:04:28.666 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 172  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.666 2009  to  Tue May  5 04:04:28.709 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 173  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:04:28.775 2009  to  Tue May  5 04:04:28.775 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 174  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue May  5 04:04:28.905 2009  to  Tue May  5 04:04:28.905 2009   (  0.00) secs
                     LDG bad poly no. 16606: t0 is 6.662779e+01 seconds in the past!

 175  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May  5 04:04:28.902 2009  to  Tue May  5 04:04:28.902 2009   (  0.00) secs
                     AZ bad poly no. 3: BAD Poly:t0 is -6.662529e+01 seconds in the past!

 176  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue May  5 04:04:28.903 2009  to  Tue May  5 04:04:28.903 2009   (  0.00) secs
                     EL bad poly no. 159347: BAD Poly:t0 is -6.662644e+01 seconds in the past!

 177  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue May  5 04:04:28.953 2009  to  Tue May  5 04:04:28.953 2009   (  0.00) secs
                     MJDsec from DSP is 4.748238302899689e+09 but t0 of the LDG target polynomial is 4.748238236277000e+09. Difference= 6.662268829345703e+01 seq=674884

 178  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:04:28.997 2009  to  Tue May  5 04:04:29.507 2009   (  0.51) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

 179  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:04:29.050 2009  to  Tue May  5 04:04:29.140 2009   (  0.09) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 180  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:04:30.857 2009  to  Tue May  5 04:04:30.857 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 181  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:04.666 2009  to  Tue May  5 04:06:05.171 2009   (  0.51) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 182  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:04.663 2009  to  Tue May  5 04:06:45.309 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at directGregorian focus

 183  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.733 2009  to  Tue May  5 04:06:04.798 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 184  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.798 2009  to  Tue May  5 04:06:04.842 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 185  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:04.911 2009  to  Tue May  5 04:06:04.911 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 186  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue May  5 04:06:07.084 2009  to  Tue May  5 04:06:07.084 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 187  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:45.309 2009  to  Tue May  5 04:06:46.502 2009   (  1.19) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianCenter focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize command failed for left IRTC at bentGregorianCenter focus

 188  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:45.374 2009  to  Tue May  5 04:06:45.447 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 189  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:06:45.555 2009  to  Tue May  5 04:06:45.555 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 190  FAILED    PSF        command.setNewInstrument                                      Tue May  5 04:06:45.946 2009  to  Tue May  5 04:06:46.335 2009   (  0.39) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

 191  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue May  5 04:06:45.999 2009  to  Tue May  5 04:06:46.055 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 192  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 04:06:46.500 2009  to  Tue May  5 04:06:46.500 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 193  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue May  5 04:06:46.556 2009  to  Tue May  5 04:06:46.556 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

 194  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue May  5 04:06:46.530 2009  to  Tue May  5 04:06:46.530 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 195  FAILED    GCS        command.setAGW                                                Tue May  5 04:08:08.839 2009  to  Tue May  5 04:08:35.576 2009   ( 26.74) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

 196  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:09:43.954 2009  to  Tue May  5 04:09:44.732 2009   (  0.78) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

 197  FAILED    IIF GUI    IIFCommand.authorize                                          Tue May  5 04:09:43.958 2009  to  Tue May  5 04:09:44.561 2009   (  0.60) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 198  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.022 2009  to  Tue May  5 04:09:44.090 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 199  FAILED    PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.090 2009  to  Tue May  5 04:09:44.134 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 200  SEQERROR  PCS        telescope.command.stopTracking                                Tue May  5 04:09:44.204 2009  to  Tue May  5 04:09:44.204 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

**********************************************************
    Reporting period ending:   Tue May  5 05:58:59.277 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback