    TCS Software Performance Report
 
    Observing Night:   May 3 2009 to May 4 2009
 
    Reporting period beginning:   Sun May  3 18:32:02.785 2009
    Reporting period ending:      Mon May  4 05:59:53.186 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = pcs.guider.command.enableGuiding.started,  priority = 0, 2
      event = pcs.guider.command.enableGuiding.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    7.06    3.04    0.44   25.42    33.3 %         12          4          8           
                                                                      12.37    6.86    0.44   25.42

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:48:46.487 2009  to  Sun May  3 18:48:48.346 2009   (  1.86) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:48:46.490 2009  to  Sun May  3 18:48:47.028 2009   (  0.54) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:01.357 2009  to  Sun May  3 18:53:02.683 2009   (  1.33) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   4  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:01.363 2009  to  Sun May  3 18:53:02.015 2009   (  0.65) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:18.006 2009  to  Sun May  3 18:53:19.348 2009   (  1.34) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:18.008 2009  to  Sun May  3 18:53:18.726 2009   (  0.72) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   7  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 19:27:53.811 2009  to  Sun May  3 19:27:55.565 2009   (  1.75) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   8  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 19:27:53.816 2009  to  Sun May  3 19:27:54.613 2009   (  0.80) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    3.09    6.26    2.09   12.20   100.0 %         17         17                      
                                                                       3.09    6.26    2.09   12.20
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    3.27    3.95    1.66   11.68   100.0 %         17         17                      
                                                                       3.27    3.95    1.66   11.68
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .  219.39  147.36    1.44  649.73    78.1 %         32         25          7               timeout =     1
                                                                     234.11  173.72   24.48  649.73
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .    0.00  456.92  456.92  456.92     0.0 %          1                     1           
                                                                                                   
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .  127.75  114.41   10.10  590.94    29.2 %         24          5         17          2
                                                                       4.38   42.50   38.03   47.21
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    0.00  202.91  202.91  202.91   100.0 %          1          1                      
                                                                       0.00  202.91  202.91  202.91
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   10.63    4.13    2.07   75.19   100.0 %         51         51                      
                                                                      10.63    4.13    2.07   75.19
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   41.94   18.04    2.06  210.44    98.0 %         51         50                      
                                                                      41.94   18.04    2.06  210.44

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             3
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 19:39:30.728 2009  to  Sun May  3 19:39:35.730 2009   (  5.00) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGw command status: AGW1: Network Error
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGw command status: AGW1: Network Errorerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0392042, 0.109685, 35.2977 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   2  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 19:42:21.838 2009  to  Sun May  3 19:42:25.119 2009   (  3.28) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGw command status: AGW1: Network Error
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGw command status: AGW1: Network Errorerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0423887, 0.110007, 35.2977 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   3  FAILED    IIF        command.preset.(ACTIVE)                                       Sun May  3 21:16:19.544 2009  to  Sun May  3 21:23:56.463 2009   (456.92) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   4  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 21:26:44.761 2009  to  Sun May  3 21:32:01.626 2009   (316.87) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   5  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 21:34:04.441 2009  to  Sun May  3 21:43:55.385 2009   (590.94) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 500 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   6  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:20:01.820 2009  to  Sun May  3 23:25:43.621 2009   (341.80) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: IIF Preset command timed out in 300 seconds for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   7  SEQERROR  IIF        command.preset.telescopeWait                                  Sun May  3 23:20:58.891 2009  to  Sun May  3 23:35:05.716 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for left IRTC

   8  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:28:16.255 2009  to  Sun May  3 23:28:17.691 2009   (  1.44) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   9  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:30:53.578 2009  to  Sun May  3 23:30:55.166 2009   (  1.59) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  10  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:47:40.437 2009  to  Sun May  3 23:52:14.380 2009   (273.94) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 500 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  11  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:53:32.039 2009  to  Sun May  3 23:54:51.950 2009   ( 79.91) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  12  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:58:23.193 2009  to  Sun May  3 23:59:37.276 2009   ( 74.08) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  13  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:02:11.941 2009  to  Mon May  4 00:03:56.735 2009   (104.79) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  14  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:09:18.022 2009  to  Mon May  4 00:09:28.120 2009   ( 10.10) secs
                     IIF Preset command started for left IRTC mode GUIDE from IIF
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -84.9235, -72.0354, 24.8883 mm.
                     IIF Preset alert for left IRTC mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  15  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:10:21.580 2009  to  Mon May  4 00:11:42.099 2009   ( 80.52) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 60
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  16  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:17:16.730 2009  to  Mon May  4 00:19:07.832 2009   (111.10) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 94
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  17  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon May  4 01:16:57.701 2009  to  Mon May  4 01:17:07.313 2009   (  9.61) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0912439, -111.293, 24.8956 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  18  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon May  4 01:20:58.696 2009  to  Mon May  4 01:21:08.548 2009   (  9.85) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0933201, -111.288, 24.8961 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  19  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:28:46.286 2009  to  Mon May  4 01:29:57.528 2009   ( 71.24) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  20  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:39:06.993 2009  to  Mon May  4 01:40:27.915 2009   ( 80.92) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  21  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:43:57.203 2009  to  Mon May  4 01:45:23.512 2009   ( 86.31) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  22  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:48:39.011 2009  to  Mon May  4 01:50:06.436 2009   ( 87.43) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  23  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:51:17.727 2009  to  Mon May  4 01:52:32.678 2009   ( 74.95) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  24  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 02:01:05.748 2009  to  Mon May  4 02:02:31.340 2009   ( 85.59) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  25  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 02:04:30.145 2009  to  Mon May  4 02:05:56.311 2009   ( 86.17) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  26  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 03:34:01.941 2009  to  Mon May  4 03:35:31.503 2009   ( 89.56) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3418                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6836                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      48                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .      13
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .   92.03   35.53    0.00  566.44    36.0 %         25         22         16          3
                                                                       8.04    4.09    0.00   23.41
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    1.72    0.96    0.00    7.41    50.0 %         22         44                      
                                                                       1.72    0.96    0.00    7.41
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         70                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         17                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06    87.5 %         16                     2           
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .    0.21    1.33    1.19    1.48    87.5 %         16                     2           
                                                                                                   
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .    1.68    0.93    0.05    3.44    95.5 %         88                     4           
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .                                   100.0 %         43                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         34                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         17                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %        102                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         76                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .   31.36   12.54    0.00  126.21    79.5 %         39         37          8           
                                                                       1.01    0.22    0.00    6.22
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         20                                 
                                                                                                   
     command.setGuideStar . . . . . . . . . . . . . . . . . . . . .    0.00    1.27    1.27    1.27     0.0 %          1                     1           
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    6.40   14.74    0.00   36.89    90.9 %         55         55          5           
                                                                       6.00   15.54    0.00   36.89
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         85                                 
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %         25                                 
                                                                                                   
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.12   100.0 %         22         22                      
                                                                       0.01    0.06    0.05    0.12
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.13    0.22    0.16    0.51     9.7 %         72          7                      
                                                                       0.13    0.22    0.16    0.51
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    3.67    8.52    0.56   22.98    89.3 %         56         50          6           
                                                                       2.74    9.41    7.11   22.98
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.34    4.41    0.21   13.99    99.9 %        676        655          1             interrupted =    19    timeout =     1
                                                                       1.29    4.40    0.21    7.11
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.11    0.20    0.17    0.98   100.0 %         55         55                      
                                                                       0.11    0.20    0.17    0.98
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.12    0.24    0.16    2.75   100.0 %        507        507                      
                                                                       0.12    0.24    0.16    2.75
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.71    2.09    1.18    4.09   100.0 %         22         22                      
                                                                       0.71    2.09    1.18    4.09

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .      22                      
 *** guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 39        698
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .      21                      

GCS Events of Interest

   1  FAILED    GCS        command.setGuidestarList                                      Sun May  3 19:39:31.753 2009  to  Sun May  3 19:39:35.404 2009   (  3.65) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

   2  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:39:32.524 2009  to  Sun May  3 19:39:35.348 2009   (  2.82) secs
                     couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGW1: Network Error

   3  FAILED    GCS        command.getFocus                                              Sun May  3 19:41:20.953 2009  to  Sun May  3 19:41:22.138 2009   (  1.19) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

   4  FAILED    GCS        command.getFilter                                             Sun May  3 19:41:22.212 2009  to  Sun May  3 19:41:22.267 2009   (  0.06) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

   5  FAILED    GCS        command.setAGW                                                Sun May  3 19:41:55.130 2009  to  Sun May  3 19:41:55.184 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

   6  FAILED    GCS        command.setGuidestarList                                      Sun May  3 19:42:23.435 2009  to  Sun May  3 19:42:24.791 2009   (  1.36) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

   7  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:42:24.179 2009  to  Sun May  3 19:42:24.737 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGW1: Network Error

   8  FAILED    GCS        command.setGuideStar                                          Sun May  3 19:45:49.083 2009  to  Sun May  3 19:45:50.349 2009   (  1.27) secs
                     oacontrol indicated a problem moving the probe onto the target position: AGW1: Network Error

   9  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:45:49.742 2009  to  Sun May  3 19:45:50.297 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0, 0, focus: 35.31 :AGW1: Network Error

  10  FAILED    GCS        command.getFocus                                              Sun May  3 19:46:00.279 2009  to  Sun May  3 19:46:01.764 2009   (  1.48) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

  11  FAILED    GCS        command.getFilter                                             Sun May  3 19:46:01.837 2009  to  Sun May  3 19:46:01.891 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

  12  STARTUP   GCS        startup                                                       Sun May  3 19:54:20.309 2009  to  Sun May  3 19:54:20.309 2009   (  0.00) secs
                     left GCS subsystem started

  13  FAILED    GCS        command.setAGW                                                Sun May  3 19:54:49.825 2009  to  Sun May  3 19:56:19.204 2009   ( 89.38) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  14  FAILED    GCS        command.setAGW                                                Sun May  3 19:58:27.267 2009  to  Sun May  3 19:59:19.842 2009   ( 52.57) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  15  FAILED    GCS        command.setAGW                                                Sun May  3 20:01:11.408 2009  to  Sun May  3 20:02:39.412 2009   ( 88.00) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  16  FAILED    GCS        command.setAGW                                                Sun May  3 20:07:35.836 2009  to  Sun May  3 20:09:42.050 2009   (126.21) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  17  SHUTDOWN  GCS        command.shutdown                                              Sun May  3 20:13:19.716 2009  to  Sun May  3 20:13:19.716 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  18  SHUTDOWN  GCS        command.shutdown                                              Sun May  3 20:13:38.540 2009  to  Sun May  3 20:13:38.540 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  19  STARTUP   GCS        startup                                                       Sun May  3 20:14:48.361 2009  to  Sun May  3 20:14:48.361 2009   (  0.00) secs
                     left GCS subsystem started

  20  FAILED    GCS        command.setAGW                                                Sun May  3 20:15:27.772 2009  to  Sun May  3 20:17:08.911 2009   (101.14) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  21  FAILED    GCS        command.setAGW                                                Sun May  3 20:21:20.740 2009  to  Sun May  3 20:22:30.033 2009   ( 69.29) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  22  STARTUP   GCS        startup                                                       Sun May  3 20:48:10.536 2009  to  Sun May  3 20:48:10.536 2009   (  0.00) secs
                     left GCS subsystem started

  23  FAILED    GCS        command.getFullGuideImage                                     Sun May  3 20:53:04.011 2009  to  Sun May  3 20:53:07.456 2009   (  3.44) secs
                     couldn''t save full WFS CCD readout to disk: guider

  24  FAILED    GCS        command.setAGW                                                Sun May  3 21:21:45.927 2009  to  Sun May  3 21:22:15.124 2009   ( 29.20) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  25  STARTUP   GCS        startup                                                       Sun May  3 21:24:08.337 2009  to  Sun May  3 21:24:08.337 2009   (  0.00) secs
                     left GCS subsystem started

  26  STARTUP   GCS        startup                                                       Sun May  3 21:32:13.516 2009  to  Sun May  3 21:32:13.516 2009   (  0.00) secs
                     left GCS subsystem started

  27  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 21:34:28.498 2009  to  Sun May  3 21:43:54.938 2009   (566.44) secs
                     guiding was not stable within 6 cycles

  28  FAILED    GCS        command.getFullGuideImage                                     Sun May  3 21:43:21.173 2009  to  Sun May  3 21:43:21.225 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

  29  STARTUP   GCS        startup                                                       Sun May  3 23:13:10.284 2009  to  Sun May  3 23:13:10.284 2009   (  0.00) secs
                     left GCS subsystem started

  30  STARTUP   GCS        startup                                                       Sun May  3 23:30:35.750 2009  to  Sun May  3 23:30:35.750 2009   (  0.00) secs
                     left GCS subsystem started

  31  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:45:50.266 2009  to  Sun May  3 23:45:50.319 2009   (  0.05) secs
                     GCS already in guiding mode.

  32  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:51:33.112 2009  to  Sun May  3 23:52:13.924 2009   ( 40.81) secs
                     guiding was not stable within 6 cycles

  33  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:54:15.376 2009  to  Sun May  3 23:54:51.588 2009   ( 36.21) secs
                     guiding was not stable within 6 cycles

  34  STARTUP   GCS        startup                                                       Sun May  3 23:57:37.987 2009  to  Sun May  3 23:57:37.987 2009   (  0.00) secs
                     left GCS subsystem started

  35  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:58:45.885 2009  to  Sun May  3 23:59:36.930 2009   ( 51.05) secs
                     guiding was not stable within 6 cycles

  36  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:23.904 2009  to  Sun May  3 23:59:23.904 2009   (  0.00) secs
                     no guide star found

  37  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:29.356 2009  to  Sun May  3 23:59:29.356 2009   (  0.00) secs
                     no guide star found

  38  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:34.845 2009  to  Sun May  3 23:59:34.845 2009   (  0.00) secs
                     no guide star found

  39  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:03:03.366 2009  to  Mon May  4 00:03:56.400 2009   ( 53.03) secs
                     guiding was not stable within 6 cycles

  40  FAILED    GCS        guidethread.warning                                           Mon May  4 00:03:48.460 2009  to  Mon May  4 00:03:48.460 2009   (  0.00) secs
                     no guide star found

  41  FAILED    GCS        guidethread.warning                                           Mon May  4 00:03:54.009 2009  to  Mon May  4 00:03:54.009 2009   (  0.00) secs
                     no guide star found

  42  FAILED    GCS        command.setGuidestarList                                      Mon May  4 00:09:19.624 2009  to  Mon May  4 00:09:27.753 2009   (  8.13) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  43  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 00:09:26.889 2009  to  Mon May  4 00:09:27.698 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGW2: Requested position is Out of Range

  44  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:11:41.603 2009  to  Mon May  4 00:11:41.603 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

  45  STARTUP   GCS        startup                                                       Mon May  4 00:16:30.678 2009  to  Mon May  4 00:16:30.678 2009   (  0.00) secs
                     left GCS subsystem started

  46  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:17:41.305 2009  to  Mon May  4 00:19:07.448 2009   ( 86.14) secs
                     guiding was not stable within 6 cycles

  47  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:12.589 2009  to  Mon May  4 00:18:12.589 2009   (  0.00) secs
                     no guide star found

  48  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:18.012 2009  to  Mon May  4 00:18:18.012 2009   (  0.00) secs
                     no guide star found

  49  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:23.447 2009  to  Mon May  4 00:18:23.447 2009   (  0.00) secs
                     no guide star found

  50  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:28.942 2009  to  Mon May  4 00:18:28.942 2009   (  0.00) secs
                     no guide star found

  51  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:34.443 2009  to  Mon May  4 00:18:34.443 2009   (  0.00) secs
                     no guide star found

  52  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:39.937 2009  to  Mon May  4 00:18:39.937 2009   (  0.00) secs
                     no guide star found

  53  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:45.420 2009  to  Mon May  4 00:18:45.420 2009   (  0.00) secs
                     no guide star found

  54  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:50.829 2009  to  Mon May  4 00:18:50.829 2009   (  0.00) secs
                     no guide star found

  55  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:56.275 2009  to  Mon May  4 00:18:56.275 2009   (  0.00) secs
                     no guide star found

  56  FAILED    GCS        guidethread.warning                                           Mon May  4 00:19:01.752 2009  to  Mon May  4 00:19:01.752 2009   (  0.00) secs
                     no guide star found

  57  FAILED    GCS        guidethread.warning                                           Mon May  4 01:05:04.918 2009  to  Mon May  4 01:05:04.918 2009   (  0.00) secs
                     no guide star found

  58  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:02.091 2009  to  Mon May  4 01:06:02.091 2009   (  0.00) secs
                     no guide star found

  59  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:07.552 2009  to  Mon May  4 01:06:07.552 2009   (  0.00) secs
                     no guide star found

  60  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:13.036 2009  to  Mon May  4 01:06:13.036 2009   (  0.00) secs
                     no guide star found

  61  FAILED    GCS        command.setGuidestarList                                      Mon May  4 01:16:59.197 2009  to  Mon May  4 01:17:06.985 2009   (  7.79) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  62  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 01:17:06.373 2009  to  Mon May  4 01:17:06.929 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGW2: Requested position is Out of Range

  63  STARTUP   GCS        startup                                                       Mon May  4 01:20:41.756 2009  to  Mon May  4 01:20:41.756 2009   (  0.00) secs
                     left GCS subsystem started

  64  FAILED    GCS        command.setGuidestarList                                      Mon May  4 01:20:59.776 2009  to  Mon May  4 01:21:08.217 2009   (  8.44) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  65  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 01:21:06.849 2009  to  Mon May  4 01:21:08.161 2009   (  1.31) secs
                     couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGW2: Requested position is Out of Range

  66  STARTUP   GCS        startup                                                       Mon May  4 01:28:26.493 2009  to  Mon May  4 01:28:26.493 2009   (  0.00) secs
                     left GCS subsystem started

  67  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:29:13.635 2009  to  Mon May  4 01:29:57.191 2009   ( 43.56) secs
                     guiding was not stable within 6 cycles

  68  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:39:31.615 2009  to  Mon May  4 01:40:27.574 2009   ( 55.96) secs
                     guiding was not stable within 6 cycles

  69  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:44:33.901 2009  to  Mon May  4 01:45:23.174 2009   ( 49.27) secs
                     guiding was not stable within 6 cycles

  70  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:49:16.308 2009  to  Mon May  4 01:50:06.092 2009   ( 49.78) secs
                     guiding was not stable within 6 cycles

  71  FAILED    GCS        guidethread.warning                                           Mon May  4 01:49:53.629 2009  to  Mon May  4 01:49:53.629 2009   (  0.00) secs
                     no guide star found

  72  FAILED    GCS        guidethread.warning                                           Mon May  4 01:49:59.130 2009  to  Mon May  4 01:49:59.130 2009   (  0.00) secs
                     no guide star found

  73  FAILED    GCS        guidethread.warning                                           Mon May  4 01:50:04.588 2009  to  Mon May  4 01:50:04.588 2009   (  0.00) secs
                     no guide star found

  74  STARTUP   GCS        startup                                                       Mon May  4 01:50:36.450 2009  to  Mon May  4 01:50:36.450 2009   (  0.00) secs
                     left GCS subsystem started

  75  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:51:41.608 2009  to  Mon May  4 01:52:32.339 2009   ( 50.73) secs
                     guiding was not stable within 6 cycles

  76  FAILED    GCS        guidethread.warning                                           Mon May  4 01:52:24.597 2009  to  Mon May  4 01:52:24.597 2009   (  0.00) secs
                     no guide star found

  77  FAILED    GCS        guidethread.warning                                           Mon May  4 01:52:30.031 2009  to  Mon May  4 01:52:30.031 2009   (  0.00) secs
                     no guide star found

  78  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 02:01:30.172 2009  to  Mon May  4 02:02:30.951 2009   ( 60.78) secs
                     guiding was not stable within 6 cycles

  79  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 02:04:56.668 2009  to  Mon May  4 02:05:55.972 2009   ( 59.30) secs
                     guiding was not stable within 6 cycles

  80  FAILED    GCS        guidethread.warning                                           Mon May  4 02:14:31.406 2009  to  Mon May  4 02:14:31.406 2009   (  0.00) secs
                     no guide star found

  81  STARTUP   GCS        startup                                                       Mon May  4 02:46:45.360 2009  to  Mon May  4 02:46:45.360 2009   (  0.00) secs
                     left GCS subsystem started

  82  FAILED    GCS        command.getFullGuideImage                                     Mon May  4 02:56:16.604 2009  to  Mon May  4 02:56:16.734 2009   (  0.13) secs
                     request to AzCam server for a full CCD readout failed

  83  FAILED    GCS        command.getFullGuideImage                                     Mon May  4 02:56:28.751 2009  to  Mon May  4 02:56:28.849 2009   (  0.10) secs
                     request to AzCam server for a full CCD readout failed

  84  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 03:34:34.146 2009  to  Mon May  4 03:35:31.152 2009   ( 57.01) secs
                     guiding was not stable within 6 cycles

  85  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 04:09:30.308 2009  to  Mon May  4 04:09:44.302 2009   ( 13.99) secs
                     timeout occured waiting for a guide image
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Sun May  3 20:20:27.546 2009  to  Sun May  3 20:20:27.546 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           154
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      67                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .     109                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     160                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       4                      
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.OpticalSupport.commandActionReceived . . . . . . . . . .       1                      
     MCSPU.Side.doingCommand. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Side.completedCommand. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.OpticalSupport.commandReceived . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.startingRetract . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.commandCompletion . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.resetSerdes . . . . . . . . . . . . . . . . . .                             4
     MCSPU.RTracker.commandToVelMode. . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rVelMode. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cEnergize . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     106                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       5                      
 *** MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                 42           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     122                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      79                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      63                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      60                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     120                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     146                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1744                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     568                      
 *** MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 26           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                 13           
     MCSPU.RTracker.setVel. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   2  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   3  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.890 2009  to  Sun May  3 18:59:03.890 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.890 2009  to  Sun May  3 18:59:03.890 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.591 2009  to  Sun May  3 19:35:19.591 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353587672e+09 but t0 of the AZ target polynomial is 4.748117239632000e+09. Difference= 4.113955672264099e+03 seq=4681502

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.592 2009  to  Sun May  3 19:35:19.592 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353589280e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.748121353589280e+09 seq=0

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.594 2009  to  Sun May  3 19:35:19.594 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353513733e+09 but t0 of the LDG target polynomial is 0.000000000000000e+00. Difference= 4.748121353513733e+09 seq=0

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 22:24:47.876 2009  to  Sun May  3 22:24:47.876 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 22:24:47.909 2009  to  Sun May  3 22:24:47.909 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  14  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 22:24:48.967 2009  to  Sun May  3 22:24:48.967 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.364 2009  to  Sun May  3 22:27:36.364 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690364279e+09 but t0 of the AZ target polynomial is 4.748131520831000e+09. Difference= 1.695332784652710e+02 seq=285224

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.365 2009  to  Sun May  3 22:27:36.365 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690366099e+09 but t0 of the EL target polynomial is 4.748131520831000e+09. Difference= 1.695350990295410e+02 seq=285224

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.366 2009  to  Sun May  3 22:27:36.366 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690359738e+09 but t0 of the LDG target polynomial is 4.748131520831000e+09. Difference= 1.695287380218506e+02 seq=285224

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:10:09.472 2009  to  Sun May  3 23:10:09.472 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:10:09.499 2009  to  Sun May  3 23:10:09.499 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  20  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:10:10.475 2009  to  Sun May  3 23:10:10.475 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.731 2009  to  Sun May  3 23:13:50.731 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464731819e+09 but t0 of the AZ target polynomial is 4.748134242454000e+09. Difference= 2.222778196334839e+02 seq=54172

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.733 2009  to  Sun May  3 23:13:50.733 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464733714e+09 but t0 of the EL target polynomial is 4.748134242454000e+09. Difference= 2.222797145843506e+02 seq=54172

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.735 2009  to  Sun May  3 23:13:50.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464645374e+09 but t0 of the LDG target polynomial is 4.748134242454000e+09. Difference= 2.221913747787476e+02 seq=54172

  24  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:20:04.554 2009  to  Sun May  3 23:20:04.554 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:33:56.762 2009  to  Sun May  3 23:33:56.762 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:33:56.774 2009  to  Sun May  3 23:33:56.774 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.043 2009  to  Sun May  3 23:34:44.043 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718043835e+09 but t0 of the AZ target polynomial is 4.748135669720000e+09. Difference= 4.832383441925049e+01 seq=28238

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.044 2009  to  Sun May  3 23:34:44.044 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718044894e+09 but t0 of the EL target polynomial is 4.748135669720000e+09. Difference= 4.832489395141602e+01 seq=28238

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.045 2009  to  Sun May  3 23:34:44.045 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718038951e+09 but t0 of the LDG target polynomial is 4.748134836458000e+09. Difference= 8.815809507369995e+02 seq=11639

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:45:53.180 2009  to  Sun May  3 23:45:53.180 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:45:53.228 2009  to  Sun May  3 23:45:53.228 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:45:54.150 2009  to  Sun May  3 23:45:54.150 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.230 2009  to  Sun May  3 23:47:41.230 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495229877e+09 but t0 of the AZ target polynomial is 4.748136386141999e+09. Difference= 1.090878782272339e+02 seq=14034

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.231 2009  to  Sun May  3 23:47:41.231 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495231033e+09 but t0 of the EL target polynomial is 4.748136386141999e+09. Difference= 1.090890340805054e+02 seq=14034

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.232 2009  to  Sun May  3 23:47:41.232 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495134983e+09 but t0 of the LDG target polynomial is 4.748136386141999e+09. Difference= 1.089929838180542e+02 seq=14034

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:49:08.707 2009  to  Sun May  3 23:49:08.707 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:49:08.763 2009  to  Sun May  3 23:49:08.763 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:49:09.679 2009  to  Sun May  3 23:49:09.679 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  39  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun May  3 23:49:13.249 2009  to  Sun May  3 23:49:13.249 2009   (  0.00) secs
                     LDG bad poly no. 16600: t0 is 5.547512e+00 seconds in the past!

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.256 2009  to  Sun May  3 23:49:13.256 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587256086e+09 but t0 of the AZ target polynomial is 4.748136581701000e+09. Difference= 5.555086135864258e+00 seq=3697

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.257 2009  to  Sun May  3 23:49:13.257 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587257349e+09 but t0 of the EL target polynomial is 4.748136581701000e+09. Difference= 5.556348800659180e+00 seq=3697

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.258 2009  to  Sun May  3 23:49:13.258 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587234512e+09 but t0 of the LDG target polynomial is 4.748136581651000e+09. Difference= 5.583512306213379e+00 seq=3696

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:00:53.852 2009  to  Mon May  4 00:00:53.852 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:00:53.903 2009  to  Mon May  4 00:00:53.903 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:00:54.969 2009  to  Mon May  4 00:00:54.969 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.750 2009  to  Mon May  4 00:02:12.750 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366749619e+09 but t0 of the AZ target polynomial is 4.748137286846000e+09. Difference= 7.990361976623535e+01 seq=17686

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.751 2009  to  Mon May  4 00:02:12.751 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366751026e+09 but t0 of the EL target polynomial is 4.748137286846000e+09. Difference= 7.990502643585205e+01 seq=17686

  48  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.752 2009  to  Mon May  4 00:02:12.752 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366730529e+09 but t0 of the LDG target polynomial is 4.748137286846000e+09. Difference= 7.988452911376953e+01 seq=17686

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:21:09.272 2009  to  Mon May  4 00:21:09.272 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:21:09.332 2009  to  Mon May  4 00:21:09.332 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:21:10.248 2009  to  Mon May  4 00:21:10.248 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon May  4 00:21:13.782 2009  to  Mon May  4 00:21:13.782 2009   (  0.00) secs
                     LDG bad poly no. 16601: t0 is 5.518375e+00 seconds in the past!

  53  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.789 2009  to  Mon May  4 00:21:13.789 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507789005e+09 but t0 of the AZ target polynomial is 4.748138502264000e+09. Difference= 5.525005340576172e+00 seq=24002

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.790 2009  to  Mon May  4 00:21:13.790 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507789979e+09 but t0 of the EL target polynomial is 4.748138502264000e+09. Difference= 5.525979042053223e+00 seq=24002

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.792 2009  to  Mon May  4 00:21:13.792 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507724694e+09 but t0 of the LDG target polynomial is 4.748138502214000e+09. Difference= 5.510694503784180e+00 seq=24001

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:30:22.176 2009  to  Mon May  4 00:30:22.176 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:30:22.214 2009  to  Mon May  4 00:30:22.214 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:30:23.156 2009  to  Mon May  4 00:30:23.156 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon May  4 00:30:26.710 2009  to  Mon May  4 00:30:26.710 2009   (  0.00) secs
                     LDG bad poly no. 16602: t0 is 5.538527e+00 seconds in the past!

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:30:26.721 2009  to  Mon May  4 00:30:26.721 2009   (  0.00) secs
                     MJDsec from DSP is 4.748139060721246e+09 but t0 of the AZ target polynomial is 4.748139055172000e+09. Difference= 5.549245834350586e+00 seq=34948

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:43:30.535 2009  to  Mon May  4 00:43:30.535 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:43:30.559 2009  to  Mon May  4 00:43:30.559 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  63  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:43:31.559 2009  to  Mon May  4 00:43:31.559 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:57:59.020 2009  to  Mon May  4 00:57:59.020 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:57:59.078 2009  to  Mon May  4 00:57:59.078 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  66  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:58:00.095 2009  to  Mon May  4 00:58:00.095 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:00:41.442 2009  to  Mon May  4 01:00:41.442 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:00:41.490 2009  to  Mon May  4 01:00:41.490 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  69  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:00:42.472 2009  to  Mon May  4 01:00:42.472 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:16:15.367 2009  to  Mon May  4 01:16:15.367 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  71  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:16:15.405 2009  to  Mon May  4 01:16:15.405 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  72  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:16:16.421 2009  to  Mon May  4 01:16:16.421 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:38:20.992 2009  to  Mon May  4 01:38:20.992 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  74  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:38:22.136 2009  to  Mon May  4 01:38:22.136 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Mon May  4 04:17:24.557 2009  to  Mon May  4 04:17:24.557 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    6.98    4.08    2.34   43.07   100.0 %         63         63                      
                                                                       6.98    4.08    2.34   43.07
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.00   23.93   23.93   23.93   100.0 %          1          1                      
                                                                       0.00   23.93   23.93   23.93

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             2

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Sun May  3 21:33:33.604 2009  to  Sun May  3 21:33:33.604 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .      10
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.01    0.06    0.05    0.13   100.0 %         55         55                      
                                                                       0.01    0.06    0.05    0.13
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.03    0.09    0.04    0.40   100.0 %        507        507                        guidingNotEnabled =   297
                                                                       0.03    0.09    0.04    0.40
     guider.command.enableGuiding . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.43    1.77    1.05    2.62   100.0 %         22         22                        largeUpdate =    21
                                                                       0.43    1.77    1.05    2.62
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.01    0.05    0.04    0.10   100.0 %         62         62                      
                                                                       0.01    0.05    0.04    0.10
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.02    0.06    0.05    0.12   100.0 %         17         17                      
                                                                       0.02    0.06    0.05    0.12
     telescope.command.reloadAuthorizedPM . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %        154        154                      
                                                                       0.01    0.05    0.04    0.11
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.04    0.07    0.05    0.19   100.0 %         58         58                      
                                                                       0.04    0.07    0.05    0.19
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.03    0.44    0.40    0.48   100.0 %          6          6                      
                                                                       0.03    0.44    0.40    0.48
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.23    0.60    0.05    1.07    98.3 %         59         56          1           
                                                                       0.22    0.61    0.31    1.07
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.03    0.03    0.00    0.09    33.3 %         12                     8           
                                                                       0.00    0.07    0.07    0.07

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .      11                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .      11                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .      11                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.556 2009  to  Sun May  3 18:48:46.630 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.630 2009  to  Sun May  3 18:48:46.678 2009   (  0.05) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.716 2009  to  Sun May  3 18:48:46.716 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.428 2009  to  Sun May  3 18:53:01.499 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   5  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.499 2009  to  Sun May  3 18:53:01.525 2009   (  0.03) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.585 2009  to  Sun May  3 18:53:01.585 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.073 2009  to  Sun May  3 18:53:18.140 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   8  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.140 2009  to  Sun May  3 18:53:18.231 2009   (  0.09) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   9  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.282 2009  to  Sun May  3 18:53:18.282 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  10  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:09:50.087 2009  to  Sun May  3 19:09:50.154 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  11  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:09:50.326 2009  to  Sun May  3 19:09:50.326 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  12  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:13.470 2009  to  Sun May  3 19:27:13.538 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  13  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:13.678 2009  to  Sun May  3 19:27:13.678 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  14  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:53.879 2009  to  Sun May  3 19:27:53.947 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  15  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 19:27:53.947 2009  to  Sun May  3 19:27:53.989 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  16  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:54.058 2009  to  Sun May  3 19:27:54.058 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  17  FAILED    PCS        telescope.command.startTracking                               Sun May  3 19:32:50.906 2009  to  Sun May  3 19:32:50.959 2009   (  0.05) secs
                     PCS will start tracking target
                     PCS could not start tracking because no target

  18  STARTUP   PCS        startup                                                       Sun May  3 22:24:57.332 2009  to  Sun May  3 22:24:57.332 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34a

  19  STARTUP   PCS        startup                                                       Sun May  3 23:10:18.523 2009  to  Sun May  3 23:10:18.523 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  20  SEQERROR  PCS        telescope.command.startTracking                               Sun May  3 23:28:16.898 2009  to  Sun May  3 23:30:54.221 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

  21  SEQERROR  PCS        telescope.command.startTracking                               Sun May  3 23:30:54.221 2009  to  Sun May  3 23:34:43.954 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

  22  STARTUP   PCS        startup                                                       Sun May  3 23:34:08.580 2009  to  Sun May  3 23:34:08.580 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  23  STARTUP   PCS        startup                                                       Sun May  3 23:46:00.739 2009  to  Sun May  3 23:46:00.739 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  24  STARTUP   PCS        startup                                                       Mon May  4 00:01:05.832 2009  to  Mon May  4 00:01:05.832 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  25  SHUTDOWN  PCS        shutdown                                                      Mon May  4 00:43:29.616 2009  to  Mon May  4 00:43:29.616 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.34b

  26  STARTUP   PCS        startup                                                       Mon May  4 00:43:50.146 2009  to  Mon May  4 00:43:50.146 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  27  STARTUP   PCS        startup                                                       Mon May  4 00:58:13.361 2009  to  Mon May  4 00:58:13.361 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  28  STARTUP   PCS        startup                                                       Mon May  4 01:00:48.359 2009  to  Mon May  4 01:00:48.359 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  29  STARTUP   PCS        startup                                                       Mon May  4 01:16:24.965 2009  to  Mon May  4 01:16:24.965 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34c

  30  STARTUP   PCS        startup                                                       Mon May  4 01:38:36.846 2009  to  Mon May  4 01:38:36.846 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.01    2.06    2.06    2.07   100.0 %          3          3                      
                                                                       0.01    2.06    2.06    2.07
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   11.39    7.28    2.05   76.19   100.0 %        119        119                      
                                                                      11.39    7.28    2.05   76.19
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06   100.0 %          2          2                      
                                                                       0.01    0.06    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       3                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       4                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             2

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Sun May  3 19:29:34.205 2009  to  Sun May  3 19:29:34.205 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Sun May  3 19:29:34.257 2009  to  Sun May  3 19:29:34.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.packetReadError                                   Sun May  3 19:51:42.520 2009  to  Sun May  3 19:51:42.520 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   4  FAILED    PMC        VxInterface.selectTimeout                                     Sun May  3 19:51:42.468 2009  to  Sun May  3 19:51:42.468 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   5  FAILED    PMC        thermal.badReceive                                            Sun May  3 19:51:42.572 2009  to  Sun May  3 19:51:42.572 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   6  FAILED    PMC        VxInterface.lengthError                                       Sun May  3 20:39:01.468 2009  to  Sun May  3 20:39:01.468 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

   7  FAILED    PMC        VxInterface.close                                             Sun May  3 20:39:01.519 2009  to  Sun May  3 20:39:01.519 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   8  FAILED    PMC        VxInterface.close                                             Mon May  4 00:24:48.656 2009  to  Mon May  4 00:24:48.656 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

   9  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 00:24:48.604 2009  to  Mon May  4 00:24:48.604 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  10  FAILED    PMC        VxInterface.close                                             Mon May  4 02:33:55.776 2009  to  Mon May  4 02:33:55.776 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  11  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 02:33:55.723 2009  to  Mon May  4 02:33:55.723 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.config . . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.02    0.28    0.27    0.35   100.0 %         68         68                      
                                                                       0.02    0.28    0.27    0.35
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.18    0.16    0.05    0.55    91.7 %         12         11          1           
                                                                       0.14    0.12    0.05    0.42
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.12   19.72   15.56   26.59   100.0 %          6          6                      
                                                                       4.12   19.72   15.56   26.59
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   11.39    7.41    2.18   76.32   100.0 %        119        119                      
                                                                      11.39    7.41    2.18   76.32
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.02    2.20    2.18    2.23   100.0 %          3          3                      
                                                                       0.02    2.20    2.18    2.23
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.04    0.07    0.06    0.14    40.0 %          5          2          3           
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   73.68   73.68   73.68   100.0 %          1          1                      
                                                                       0.00   73.68   73.68   73.68
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   13.86    9.70    2.29   76.43   100.0 %         33         33                      
                                                                      13.86    9.70    2.29   76.43
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          5          5                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.09   100.0 %         68         68                      
                                                                       0.00    0.05    0.05    0.09
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    6.07    9.15    3.29   20.32   100.0 %         12         12                      
                                                                       6.07    9.15    3.29   20.32
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          5          5                      
                                                                       0.00    0.06    0.05    0.06
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    6.98    4.21    2.46   43.20   100.0 %         63         63                      
                                                                       6.98    4.21    2.46   43.20
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.06    0.05    0.11   100.0 %         68         68                      
                                                                       0.01    0.06    0.05    0.11
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.02    0.07    0.06    0.11   100.0 %          6          6                      
                                                                       0.02    0.07    0.06    0.11
     secondaryMirror.command.revert . . . . . . . . . . . . . . . .    0.00   41.72   41.72   41.72   100.0 %          1          1                      
                                                                       0.00   41.72   41.72   41.72
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.02    0.07    0.05    0.09   100.0 %          3          3                      
                                                                       0.02    0.07    0.05    0.09

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Sun May  3 18:48:47.489 2009  to  Sun May  3 18:48:48.034 2009   (  0.55) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 18:48:47.541 2009  to  Sun May  3 18:48:47.682 2009   (  0.14) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 18:51:56.012 2009  to  Sun May  3 18:51:56.069 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   4  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 19:10:27.045 2009  to  Sun May  3 19:10:27.101 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:48:46.487 2009  to  Sun May  3 18:48:48.346 2009   (  1.86) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left IRTC at directGregorian focus: left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:48:46.490 2009  to  Sun May  3 18:48:47.028 2009   (  0.54) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.556 2009  to  Sun May  3 18:48:46.630 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.630 2009  to  Sun May  3 18:48:46.678 2009   (  0.05) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   5  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:48:46.716 2009  to  Sun May  3 18:48:46.716 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  FAILED    PSF        command.setNewInstrument                                      Sun May  3 18:48:47.489 2009  to  Sun May  3 18:48:48.034 2009   (  0.55) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument IRTCD, focal station directGregorian

   7  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 18:48:47.541 2009  to  Sun May  3 18:48:47.682 2009   (  0.14) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   8  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 18:51:56.012 2009  to  Sun May  3 18:51:56.069 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   9  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:01.357 2009  to  Sun May  3 18:53:02.683 2009   (  1.33) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  10  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:01.363 2009  to  Sun May  3 18:53:02.015 2009   (  0.65) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  11  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.428 2009  to  Sun May  3 18:53:01.499 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  12  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.499 2009  to  Sun May  3 18:53:01.525 2009   (  0.03) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  13  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:01.585 2009  to  Sun May  3 18:53:01.585 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  14  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.073 2009  to  Sun May  3 18:53:18.140 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  15  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:18.006 2009  to  Sun May  3 18:53:19.348 2009   (  1.34) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  16  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 18:53:18.008 2009  to  Sun May  3 18:53:18.726 2009   (  0.72) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  17  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.140 2009  to  Sun May  3 18:53:18.231 2009   (  0.09) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  18  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 18:53:18.282 2009  to  Sun May  3 18:53:18.282 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.889 2009  to  Sun May  3 18:59:03.889 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.890 2009  to  Sun May  3 18:59:03.890 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.890 2009  to  Sun May  3 18:59:03.890 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Sun May  3 18:59:03.891 2009  to  Sun May  3 18:59:03.891 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:09:50.087 2009  to  Sun May  3 19:09:50.154 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  28  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:09:50.326 2009  to  Sun May  3 19:09:50.326 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  29  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun May  3 19:10:27.045 2009  to  Sun May  3 19:10:27.101 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  30  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:13.470 2009  to  Sun May  3 19:27:13.538 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  31  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:13.678 2009  to  Sun May  3 19:27:13.678 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  32  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 19:27:53.811 2009  to  Sun May  3 19:27:55.565 2009   (  1.75) secs
                     IIF TCS authorize alert for left IRTC at directGregorian focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at directGregorian focus

  33  FAILED    IIF GUI    IIFCommand.authorize                                          Sun May  3 19:27:53.816 2009  to  Sun May  3 19:27:54.613 2009   (  0.80) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  34  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:53.879 2009  to  Sun May  3 19:27:53.947 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  35  FAILED    PCS        telescope.command.stopTracking                                Sun May  3 19:27:53.947 2009  to  Sun May  3 19:27:53.989 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  36  SEQERROR  PCS        telescope.command.stopTracking                                Sun May  3 19:27:54.058 2009  to  Sun May  3 19:27:54.058 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  37  FAILED    PMC        VxInterface.lengthError                                       Sun May  3 19:29:34.205 2009  to  Sun May  3 19:29:34.205 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        VxInterface.close                                             Sun May  3 19:29:34.257 2009  to  Sun May  3 19:29:34.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  39  FAILED    PCS        telescope.command.startTracking                               Sun May  3 19:32:50.906 2009  to  Sun May  3 19:32:50.959 2009   (  0.05) secs
                     PCS will start tracking target
                     PCS could not start tracking because no target

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.591 2009  to  Sun May  3 19:35:19.591 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353587672e+09 but t0 of the AZ target polynomial is 4.748117239632000e+09. Difference= 4.113955672264099e+03 seq=4681502

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.592 2009  to  Sun May  3 19:35:19.592 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353589280e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.748121353589280e+09 seq=0

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 19:35:19.594 2009  to  Sun May  3 19:35:19.594 2009   (  0.00) secs
                     MJDsec from DSP is 4.748121353513733e+09 but t0 of the LDG target polynomial is 0.000000000000000e+00. Difference= 4.748121353513733e+09 seq=0

  43  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 19:39:30.728 2009  to  Sun May  3 19:39:35.730 2009   (  5.00) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGw command status: AGW1: Network Error
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGw command status: AGW1: Network Errorerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0392042, 0.109685, 35.2977 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  44  FAILED    GCS        command.setGuidestarList                                      Sun May  3 19:39:31.753 2009  to  Sun May  3 19:39:35.404 2009   (  3.65) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  45  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:39:32.524 2009  to  Sun May  3 19:39:35.348 2009   (  2.82) secs
                     couldn''t move probe to position (SFP) 0.0392042, 0.109685, focus: 35.2977 :AGW1: Network Error

  46  FAILED    GCS        command.getFocus                                              Sun May  3 19:41:20.953 2009  to  Sun May  3 19:41:22.138 2009   (  1.19) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

  47  FAILED    GCS        command.getFilter                                             Sun May  3 19:41:22.212 2009  to  Sun May  3 19:41:22.267 2009   (  0.06) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

  48  FAILED    GCS        command.setAGW                                                Sun May  3 19:41:55.130 2009  to  Sun May  3 19:41:55.184 2009   (  0.05) secs
                     COULD NOT change active AGW configuration to junk

  49  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 19:42:21.838 2009  to  Sun May  3 19:42:25.119 2009   (  3.28) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGw command status: AGW1: Network Error
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGw command status: AGW1: Network Errorerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0423887, 0.110007, 35.2977 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  50  FAILED    GCS        command.setGuidestarList                                      Sun May  3 19:42:23.435 2009  to  Sun May  3 19:42:24.791 2009   (  1.36) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  51  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:42:24.179 2009  to  Sun May  3 19:42:24.737 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0.0423887, 0.110007, focus: 35.2977 :AGW1: Network Error

  52  FAILED    GCS        command.setGuideStar                                          Sun May  3 19:45:49.083 2009  to  Sun May  3 19:45:50.349 2009   (  1.27) secs
                     oacontrol indicated a problem moving the probe onto the target position: AGW1: Network Error

  53  FAILED    GCS        interface.agw.setProbePosition                                Sun May  3 19:45:49.742 2009  to  Sun May  3 19:45:50.297 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0, 0, focus: 35.31 :AGW1: Network Error

  54  FAILED    GCS        command.getFocus                                              Sun May  3 19:46:00.279 2009  to  Sun May  3 19:46:01.764 2009   (  1.48) secs
                     oacontrol returned an error determining the current focus: AGW1: Network Error

  55  FAILED    GCS        command.getFilter                                             Sun May  3 19:46:01.837 2009  to  Sun May  3 19:46:01.891 2009   (  0.05) secs
                     AGWDevice->getFilter() failed with: AGW1: Network Error

  56  FAILED    PMC        VxInterface.packetReadError                                   Sun May  3 19:51:42.520 2009  to  Sun May  3 19:51:42.520 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  57  FAILED    PMC        VxInterface.selectTimeout                                     Sun May  3 19:51:42.468 2009  to  Sun May  3 19:51:42.468 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  58  FAILED    PMC        thermal.badReceive                                            Sun May  3 19:51:42.572 2009  to  Sun May  3 19:51:42.572 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  59  STARTUP   GCS        startup                                                       Sun May  3 19:54:20.309 2009  to  Sun May  3 19:54:20.309 2009   (  0.00) secs
                     left GCS subsystem started

  60  FAILED    GCS        command.setAGW                                                Sun May  3 19:54:49.825 2009  to  Sun May  3 19:56:19.204 2009   ( 89.38) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  61  FAILED    GCS        command.setAGW                                                Sun May  3 19:58:27.267 2009  to  Sun May  3 19:59:19.842 2009   ( 52.57) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  62  FAILED    GCS        command.setAGW                                                Sun May  3 20:01:11.408 2009  to  Sun May  3 20:02:39.412 2009   ( 88.00) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  63  FAILED    GCS        command.setAGW                                                Sun May  3 20:07:35.836 2009  to  Sun May  3 20:09:42.050 2009   (126.21) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  64  SHUTDOWN  GCS        command.shutdown                                              Sun May  3 20:13:19.716 2009  to  Sun May  3 20:13:19.716 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  65  SHUTDOWN  GCS        command.shutdown                                              Sun May  3 20:13:38.540 2009  to  Sun May  3 20:13:38.540 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  66  STARTUP   GCS        startup                                                       Sun May  3 20:14:48.361 2009  to  Sun May  3 20:14:48.361 2009   (  0.00) secs
                     left GCS subsystem started

  67  FAILED    GCS        command.setAGW                                                Sun May  3 20:15:27.772 2009  to  Sun May  3 20:17:08.911 2009   (101.14) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  68  STARTUP   LSS        startup                                                       Sun May  3 20:20:27.546 2009  to  Sun May  3 20:20:27.546 2009   (  0.00) secs
                     The LSS was started.

  69  FAILED    GCS        command.setAGW                                                Sun May  3 20:21:20.740 2009  to  Sun May  3 20:22:30.033 2009   ( 69.29) secs
                     COULD NOT change active AGW configuration to AIP_DG_L.cfg

  70  FAILED    PMC        VxInterface.lengthError                                       Sun May  3 20:39:01.468 2009  to  Sun May  3 20:39:01.468 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  71  FAILED    PMC        VxInterface.close                                             Sun May  3 20:39:01.519 2009  to  Sun May  3 20:39:01.519 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  72  STARTUP   GCS        startup                                                       Sun May  3 20:48:10.536 2009  to  Sun May  3 20:48:10.536 2009   (  0.00) secs
                     left GCS subsystem started

  73  FAILED    GCS        command.getFullGuideImage                                     Sun May  3 20:53:04.011 2009  to  Sun May  3 20:53:07.456 2009   (  3.44) secs
                     couldn''t save full WFS CCD readout to disk: guider

  74  FAILED    IIF        command.preset.(ACTIVE)                                       Sun May  3 21:16:19.544 2009  to  Sun May  3 21:23:56.463 2009   (456.92) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  75  FAILED    GCS        command.setAGW                                                Sun May  3 21:21:45.927 2009  to  Sun May  3 21:22:15.124 2009   ( 29.20) secs
                     COULD NOT change active AGW configuration to AIP_L.cfg

  76  STARTUP   GCS        startup                                                       Sun May  3 21:24:08.337 2009  to  Sun May  3 21:24:08.337 2009   (  0.00) secs
                     left GCS subsystem started

  77  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 21:26:44.761 2009  to  Sun May  3 21:32:01.626 2009   (316.87) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  78  STARTUP   GCS        startup                                                       Sun May  3 21:32:13.516 2009  to  Sun May  3 21:32:13.516 2009   (  0.00) secs
                     left GCS subsystem started

  79  STARTUP   OSS        startup                                                       Sun May  3 21:33:33.604 2009  to  Sun May  3 21:33:33.604 2009   (  0.00) secs
                     The oss was started.

  80  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 21:34:04.441 2009  to  Sun May  3 21:43:55.385 2009   (590.94) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 500 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  81  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 21:34:28.498 2009  to  Sun May  3 21:43:54.938 2009   (566.44) secs
                     guiding was not stable within 6 cycles

  82  FAILED    GCS        command.getFullGuideImage                                     Sun May  3 21:43:21.173 2009  to  Sun May  3 21:43:21.225 2009   (  0.05) secs
                     request to AzCam server for a full CCD readout failed

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 22:24:47.876 2009  to  Sun May  3 22:24:47.876 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 22:24:47.909 2009  to  Sun May  3 22:24:47.909 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  85  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 22:24:48.967 2009  to  Sun May  3 22:24:48.967 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  86  STARTUP   PCS        startup                                                       Sun May  3 22:24:57.332 2009  to  Sun May  3 22:24:57.332 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34a

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.364 2009  to  Sun May  3 22:27:36.364 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690364279e+09 but t0 of the AZ target polynomial is 4.748131520831000e+09. Difference= 1.695332784652710e+02 seq=285224

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.365 2009  to  Sun May  3 22:27:36.365 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690366099e+09 but t0 of the EL target polynomial is 4.748131520831000e+09. Difference= 1.695350990295410e+02 seq=285224

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 22:27:36.366 2009  to  Sun May  3 22:27:36.366 2009   (  0.00) secs
                     MJDsec from DSP is 4.748131690359738e+09 but t0 of the LDG target polynomial is 4.748131520831000e+09. Difference= 1.695287380218506e+02 seq=285224

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:10:09.472 2009  to  Sun May  3 23:10:09.472 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:10:09.499 2009  to  Sun May  3 23:10:09.499 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  92  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:10:10.475 2009  to  Sun May  3 23:10:10.475 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

  93  STARTUP   PCS        startup                                                       Sun May  3 23:10:18.523 2009  to  Sun May  3 23:10:18.523 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

  94  STARTUP   GCS        startup                                                       Sun May  3 23:13:10.284 2009  to  Sun May  3 23:13:10.284 2009   (  0.00) secs
                     left GCS subsystem started

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.731 2009  to  Sun May  3 23:13:50.731 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464731819e+09 but t0 of the AZ target polynomial is 4.748134242454000e+09. Difference= 2.222778196334839e+02 seq=54172

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.733 2009  to  Sun May  3 23:13:50.733 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464733714e+09 but t0 of the EL target polynomial is 4.748134242454000e+09. Difference= 2.222797145843506e+02 seq=54172

  97  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:13:50.735 2009  to  Sun May  3 23:13:50.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.748134464645374e+09 but t0 of the LDG target polynomial is 4.748134242454000e+09. Difference= 2.221913747787476e+02 seq=54172

  98  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:20:01.820 2009  to  Sun May  3 23:25:43.621 2009   (341.80) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: IIF Preset command timed out in 300 seconds for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  99  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:20:04.554 2009  to  Sun May  3 23:20:04.554 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 100  SEQERROR  IIF        command.preset.telescopeWait                                  Sun May  3 23:20:58.891 2009  to  Sun May  3 23:35:05.716 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for telescope started for left IRTC

 101  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:28:16.255 2009  to  Sun May  3 23:28:17.691 2009   (  1.44) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 102  SEQERROR  PCS        telescope.command.startTracking                               Sun May  3 23:28:16.898 2009  to  Sun May  3 23:30:54.221 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

 103  STARTUP   GCS        startup                                                       Sun May  3 23:30:35.750 2009  to  Sun May  3 23:30:35.750 2009   (  0.00) secs
                     left GCS subsystem started

 104  FAILED    IIF        command.preset.(ACQUIRE)                                      Sun May  3 23:30:53.578 2009  to  Sun May  3 23:30:55.166 2009   (  1.59) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 105  SEQERROR  PCS        telescope.command.startTracking                               Sun May  3 23:30:54.221 2009  to  Sun May  3 23:34:43.954 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

 106  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:33:56.762 2009  to  Sun May  3 23:33:56.762 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 107  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:33:56.774 2009  to  Sun May  3 23:33:56.774 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 108  STARTUP   PCS        startup                                                       Sun May  3 23:34:08.580 2009  to  Sun May  3 23:34:08.580 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.043 2009  to  Sun May  3 23:34:44.043 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718043835e+09 but t0 of the AZ target polynomial is 4.748135669720000e+09. Difference= 4.832383441925049e+01 seq=28238

 110  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.044 2009  to  Sun May  3 23:34:44.044 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718044894e+09 but t0 of the EL target polynomial is 4.748135669720000e+09. Difference= 4.832489395141602e+01 seq=28238

 111  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:34:44.045 2009  to  Sun May  3 23:34:44.045 2009   (  0.00) secs
                     MJDsec from DSP is 4.748135718038951e+09 but t0 of the LDG target polynomial is 4.748134836458000e+09. Difference= 8.815809507369995e+02 seq=11639

 112  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:45:50.266 2009  to  Sun May  3 23:45:50.319 2009   (  0.05) secs
                     GCS already in guiding mode.

 113  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:45:53.180 2009  to  Sun May  3 23:45:53.180 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 114  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:45:53.228 2009  to  Sun May  3 23:45:53.228 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 115  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:45:54.150 2009  to  Sun May  3 23:45:54.150 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 116  STARTUP   PCS        startup                                                       Sun May  3 23:46:00.739 2009  to  Sun May  3 23:46:00.739 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 117  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:47:40.437 2009  to  Sun May  3 23:52:14.380 2009   (273.94) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 500 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 118  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.230 2009  to  Sun May  3 23:47:41.230 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495229877e+09 but t0 of the AZ target polynomial is 4.748136386141999e+09. Difference= 1.090878782272339e+02 seq=14034

 119  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.231 2009  to  Sun May  3 23:47:41.231 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495231033e+09 but t0 of the EL target polynomial is 4.748136386141999e+09. Difference= 1.090890340805054e+02 seq=14034

 120  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:47:41.232 2009  to  Sun May  3 23:47:41.232 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136495134983e+09 but t0 of the LDG target polynomial is 4.748136386141999e+09. Difference= 1.089929838180542e+02 seq=14034

 121  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:49:08.707 2009  to  Sun May  3 23:49:08.707 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 122  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun May  3 23:49:08.763 2009  to  Sun May  3 23:49:08.763 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 123  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun May  3 23:49:09.679 2009  to  Sun May  3 23:49:09.679 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 124  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun May  3 23:49:13.249 2009  to  Sun May  3 23:49:13.249 2009   (  0.00) secs
                     LDG bad poly no. 16600: t0 is 5.547512e+00 seconds in the past!

 125  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.256 2009  to  Sun May  3 23:49:13.256 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587256086e+09 but t0 of the AZ target polynomial is 4.748136581701000e+09. Difference= 5.555086135864258e+00 seq=3697

 126  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.257 2009  to  Sun May  3 23:49:13.257 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587257349e+09 but t0 of the EL target polynomial is 4.748136581701000e+09. Difference= 5.556348800659180e+00 seq=3697

 127  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun May  3 23:49:13.258 2009  to  Sun May  3 23:49:13.258 2009   (  0.00) secs
                     MJDsec from DSP is 4.748136587234512e+09 but t0 of the LDG target polynomial is 4.748136581651000e+09. Difference= 5.583512306213379e+00 seq=3696

 128  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:51:33.112 2009  to  Sun May  3 23:52:13.924 2009   ( 40.81) secs
                     guiding was not stable within 6 cycles

 129  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:53:32.039 2009  to  Sun May  3 23:54:51.950 2009   ( 79.91) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 130  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:54:15.376 2009  to  Sun May  3 23:54:51.588 2009   ( 36.21) secs
                     guiding was not stable within 6 cycles

 131  STARTUP   GCS        startup                                                       Sun May  3 23:57:37.987 2009  to  Sun May  3 23:57:37.987 2009   (  0.00) secs
                     left GCS subsystem started

 132  FAILED    IIF        command.preset.(GUIDE)                                        Sun May  3 23:58:23.193 2009  to  Sun May  3 23:59:37.276 2009   ( 74.08) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 133  FAILED    GCS        command.autoAcquireGuidestar                                  Sun May  3 23:58:45.885 2009  to  Sun May  3 23:59:36.930 2009   ( 51.05) secs
                     guiding was not stable within 6 cycles

 134  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:23.904 2009  to  Sun May  3 23:59:23.904 2009   (  0.00) secs
                     no guide star found

 135  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:29.356 2009  to  Sun May  3 23:59:29.356 2009   (  0.00) secs
                     no guide star found

 136  FAILED    GCS        guidethread.warning                                           Sun May  3 23:59:34.845 2009  to  Sun May  3 23:59:34.845 2009   (  0.00) secs
                     no guide star found

 137  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:00:53.852 2009  to  Mon May  4 00:00:53.852 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 138  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:00:53.903 2009  to  Mon May  4 00:00:53.903 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 139  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:00:54.969 2009  to  Mon May  4 00:00:54.969 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 140  STARTUP   PCS        startup                                                       Mon May  4 00:01:05.832 2009  to  Mon May  4 00:01:05.832 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 141  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:02:11.941 2009  to  Mon May  4 00:03:56.735 2009   (104.79) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 142  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.750 2009  to  Mon May  4 00:02:12.750 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366749619e+09 but t0 of the AZ target polynomial is 4.748137286846000e+09. Difference= 7.990361976623535e+01 seq=17686

 143  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.751 2009  to  Mon May  4 00:02:12.751 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366751026e+09 but t0 of the EL target polynomial is 4.748137286846000e+09. Difference= 7.990502643585205e+01 seq=17686

 144  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:02:12.752 2009  to  Mon May  4 00:02:12.752 2009   (  0.00) secs
                     MJDsec from DSP is 4.748137366730529e+09 but t0 of the LDG target polynomial is 4.748137286846000e+09. Difference= 7.988452911376953e+01 seq=17686

 145  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:03:03.366 2009  to  Mon May  4 00:03:56.400 2009   ( 53.03) secs
                     guiding was not stable within 6 cycles

 146  FAILED    GCS        guidethread.warning                                           Mon May  4 00:03:48.460 2009  to  Mon May  4 00:03:48.460 2009   (  0.00) secs
                     no guide star found

 147  FAILED    GCS        guidethread.warning                                           Mon May  4 00:03:54.009 2009  to  Mon May  4 00:03:54.009 2009   (  0.00) secs
                     no guide star found

 148  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:09:18.022 2009  to  Mon May  4 00:09:28.120 2009   ( 10.10) secs
                     IIF Preset command started for left IRTC mode GUIDE from IIF
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -84.9235, -72.0354, 24.8883 mm.
                     IIF Preset alert for left IRTC mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 149  FAILED    GCS        command.setGuidestarList                                      Mon May  4 00:09:19.624 2009  to  Mon May  4 00:09:27.753 2009   (  8.13) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 150  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 00:09:26.889 2009  to  Mon May  4 00:09:27.698 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -84.9235, -72.0354, focus: 24.8883 :AGW2: Requested position is Out of Range

 151  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:10:21.580 2009  to  Mon May  4 00:11:42.099 2009   ( 80.52) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 60
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 152  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:11:41.603 2009  to  Mon May  4 00:11:41.603 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

 153  STARTUP   GCS        startup                                                       Mon May  4 00:16:30.678 2009  to  Mon May  4 00:16:30.678 2009   (  0.00) secs
                     left GCS subsystem started

 154  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 00:17:16.730 2009  to  Mon May  4 00:19:07.832 2009   (111.10) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 94
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 155  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 00:17:41.305 2009  to  Mon May  4 00:19:07.448 2009   ( 86.14) secs
                     guiding was not stable within 6 cycles

 156  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:12.589 2009  to  Mon May  4 00:18:12.589 2009   (  0.00) secs
                     no guide star found

 157  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:18.012 2009  to  Mon May  4 00:18:18.012 2009   (  0.00) secs
                     no guide star found

 158  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:23.447 2009  to  Mon May  4 00:18:23.447 2009   (  0.00) secs
                     no guide star found

 159  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:28.942 2009  to  Mon May  4 00:18:28.942 2009   (  0.00) secs
                     no guide star found

 160  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:34.443 2009  to  Mon May  4 00:18:34.443 2009   (  0.00) secs
                     no guide star found

 161  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:39.937 2009  to  Mon May  4 00:18:39.937 2009   (  0.00) secs
                     no guide star found

 162  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:45.420 2009  to  Mon May  4 00:18:45.420 2009   (  0.00) secs
                     no guide star found

 163  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:50.829 2009  to  Mon May  4 00:18:50.829 2009   (  0.00) secs
                     no guide star found

 164  FAILED    GCS        guidethread.warning                                           Mon May  4 00:18:56.275 2009  to  Mon May  4 00:18:56.275 2009   (  0.00) secs
                     no guide star found

 165  FAILED    GCS        guidethread.warning                                           Mon May  4 00:19:01.752 2009  to  Mon May  4 00:19:01.752 2009   (  0.00) secs
                     no guide star found

 166  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:21:09.272 2009  to  Mon May  4 00:21:09.272 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 167  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:21:09.332 2009  to  Mon May  4 00:21:09.332 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 168  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:21:10.248 2009  to  Mon May  4 00:21:10.248 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 169  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon May  4 00:21:13.782 2009  to  Mon May  4 00:21:13.782 2009   (  0.00) secs
                     LDG bad poly no. 16601: t0 is 5.518375e+00 seconds in the past!

 170  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.789 2009  to  Mon May  4 00:21:13.789 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507789005e+09 but t0 of the AZ target polynomial is 4.748138502264000e+09. Difference= 5.525005340576172e+00 seq=24002

 171  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.790 2009  to  Mon May  4 00:21:13.790 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507789979e+09 but t0 of the EL target polynomial is 4.748138502264000e+09. Difference= 5.525979042053223e+00 seq=24002

 172  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:21:13.792 2009  to  Mon May  4 00:21:13.792 2009   (  0.00) secs
                     MJDsec from DSP is 4.748138507724694e+09 but t0 of the LDG target polynomial is 4.748138502214000e+09. Difference= 5.510694503784180e+00 seq=24001

 173  FAILED    PMC        VxInterface.close                                             Mon May  4 00:24:48.656 2009  to  Mon May  4 00:24:48.656 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

 174  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 00:24:48.604 2009  to  Mon May  4 00:24:48.604 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

 175  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:30:22.176 2009  to  Mon May  4 00:30:22.176 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 176  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:30:22.214 2009  to  Mon May  4 00:30:22.214 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 177  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:30:23.156 2009  to  Mon May  4 00:30:23.156 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 178  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Mon May  4 00:30:26.710 2009  to  Mon May  4 00:30:26.710 2009   (  0.00) secs
                     LDG bad poly no. 16602: t0 is 5.538527e+00 seconds in the past!

 179  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon May  4 00:30:26.721 2009  to  Mon May  4 00:30:26.721 2009   (  0.00) secs
                     MJDsec from DSP is 4.748139060721246e+09 but t0 of the AZ target polynomial is 4.748139055172000e+09. Difference= 5.549245834350586e+00 seq=34948

 180  SHUTDOWN  PCS        shutdown                                                      Mon May  4 00:43:29.616 2009  to  Mon May  4 00:43:29.616 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.34b

 181  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:43:30.535 2009  to  Mon May  4 00:43:30.535 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 182  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:43:30.559 2009  to  Mon May  4 00:43:30.559 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 183  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:43:31.559 2009  to  Mon May  4 00:43:31.559 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 184  STARTUP   PCS        startup                                                       Mon May  4 00:43:50.146 2009  to  Mon May  4 00:43:50.146 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 185  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:57:59.020 2009  to  Mon May  4 00:57:59.020 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 186  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 00:57:59.078 2009  to  Mon May  4 00:57:59.078 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 187  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 00:58:00.095 2009  to  Mon May  4 00:58:00.095 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 188  STARTUP   PCS        startup                                                       Mon May  4 00:58:13.361 2009  to  Mon May  4 00:58:13.361 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 189  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:00:41.442 2009  to  Mon May  4 01:00:41.442 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 190  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:00:41.490 2009  to  Mon May  4 01:00:41.490 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 191  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:00:42.472 2009  to  Mon May  4 01:00:42.472 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 192  STARTUP   PCS        startup                                                       Mon May  4 01:00:48.359 2009  to  Mon May  4 01:00:48.359 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 193  FAILED    GCS        guidethread.warning                                           Mon May  4 01:05:04.918 2009  to  Mon May  4 01:05:04.918 2009   (  0.00) secs
                     no guide star found

 194  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:02.091 2009  to  Mon May  4 01:06:02.091 2009   (  0.00) secs
                     no guide star found

 195  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:07.552 2009  to  Mon May  4 01:06:07.552 2009   (  0.00) secs
                     no guide star found

 196  FAILED    GCS        guidethread.warning                                           Mon May  4 01:06:13.036 2009  to  Mon May  4 01:06:13.036 2009   (  0.00) secs
                     no guide star found

 197  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:16:15.367 2009  to  Mon May  4 01:16:15.367 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 198  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:16:15.405 2009  to  Mon May  4 01:16:15.405 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 199  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:16:16.421 2009  to  Mon May  4 01:16:16.421 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 200  STARTUP   PCS        startup                                                       Mon May  4 01:16:24.965 2009  to  Mon May  4 01:16:24.965 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34c

 201  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon May  4 01:16:57.701 2009  to  Mon May  4 01:17:07.313 2009   (  9.61) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0912439, -111.293, 24.8956 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 202  FAILED    GCS        command.setGuidestarList                                      Mon May  4 01:16:59.197 2009  to  Mon May  4 01:17:06.985 2009   (  7.79) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 203  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 01:17:06.373 2009  to  Mon May  4 01:17:06.929 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 0.0912439, -111.293, focus: 24.8956 :AGW2: Requested position is Out of Range

 204  STARTUP   GCS        startup                                                       Mon May  4 01:20:41.756 2009  to  Mon May  4 01:20:41.756 2009   (  0.00) secs
                     left GCS subsystem started

 205  FAILED    IIF        command.preset.(ACQUIRE)                                      Mon May  4 01:20:58.696 2009  to  Mon May  4 01:21:08.548 2009   (  9.85) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGw command status: AGW2: Requested position is Out of Range
                     IIF Preset alert for left IRTC mode ACQUIRE: couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGw command status: AGW2: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.0933201, -111.288, 24.8961 mm.
                     IIF Preset alert for left IRTC mode ACQUIRE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 206  FAILED    GCS        command.setGuidestarList                                      Mon May  4 01:20:59.776 2009  to  Mon May  4 01:21:08.217 2009   (  8.44) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 207  FAILED    GCS        interface.agw.setProbePosition                                Mon May  4 01:21:06.849 2009  to  Mon May  4 01:21:08.161 2009   (  1.31) secs
                     couldn''t move probe to position (SFP) 0.0933201, -111.288, focus: 24.8961 :AGW2: Requested position is Out of Range

 208  STARTUP   GCS        startup                                                       Mon May  4 01:28:26.493 2009  to  Mon May  4 01:28:26.493 2009   (  0.00) secs
                     left GCS subsystem started

 209  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:28:46.286 2009  to  Mon May  4 01:29:57.528 2009   ( 71.24) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 210  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:29:13.635 2009  to  Mon May  4 01:29:57.191 2009   ( 43.56) secs
                     guiding was not stable within 6 cycles

 211  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon May  4 01:38:20.992 2009  to  Mon May  4 01:38:20.992 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 212  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon May  4 01:38:22.136 2009  to  Mon May  4 01:38:22.136 2009   (  0.00) secs
                     There have been no LDG track polys for 2.000000000000000e+00 .

 213  STARTUP   PCS        startup                                                       Mon May  4 01:38:36.846 2009  to  Mon May  4 01:38:36.846 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34b

 214  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:39:06.993 2009  to  Mon May  4 01:40:27.915 2009   ( 80.92) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 215  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:39:31.615 2009  to  Mon May  4 01:40:27.574 2009   ( 55.96) secs
                     guiding was not stable within 6 cycles

 216  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:43:57.203 2009  to  Mon May  4 01:45:23.512 2009   ( 86.31) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 217  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:44:33.901 2009  to  Mon May  4 01:45:23.174 2009   ( 49.27) secs
                     guiding was not stable within 6 cycles

 218  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:48:39.011 2009  to  Mon May  4 01:50:06.436 2009   ( 87.43) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 219  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:49:16.308 2009  to  Mon May  4 01:50:06.092 2009   ( 49.78) secs
                     guiding was not stable within 6 cycles

 220  FAILED    GCS        guidethread.warning                                           Mon May  4 01:49:53.629 2009  to  Mon May  4 01:49:53.629 2009   (  0.00) secs
                     no guide star found

 221  FAILED    GCS        guidethread.warning                                           Mon May  4 01:49:59.130 2009  to  Mon May  4 01:49:59.130 2009   (  0.00) secs
                     no guide star found

 222  FAILED    GCS        guidethread.warning                                           Mon May  4 01:50:04.588 2009  to  Mon May  4 01:50:04.588 2009   (  0.00) secs
                     no guide star found

 223  STARTUP   GCS        startup                                                       Mon May  4 01:50:36.450 2009  to  Mon May  4 01:50:36.450 2009   (  0.00) secs
                     left GCS subsystem started

 224  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 01:51:17.727 2009  to  Mon May  4 01:52:32.678 2009   ( 74.95) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 225  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 01:51:41.608 2009  to  Mon May  4 01:52:32.339 2009   ( 50.73) secs
                     guiding was not stable within 6 cycles

 226  FAILED    GCS        guidethread.warning                                           Mon May  4 01:52:24.597 2009  to  Mon May  4 01:52:24.597 2009   (  0.00) secs
                     no guide star found

 227  FAILED    GCS        guidethread.warning                                           Mon May  4 01:52:30.031 2009  to  Mon May  4 01:52:30.031 2009   (  0.00) secs
                     no guide star found

 228  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 02:01:05.748 2009  to  Mon May  4 02:02:31.340 2009   ( 85.59) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 229  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 02:01:30.172 2009  to  Mon May  4 02:02:30.951 2009   ( 60.78) secs
                     guiding was not stable within 6 cycles

 230  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 02:04:30.145 2009  to  Mon May  4 02:05:56.311 2009   ( 86.17) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 231  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 02:04:56.668 2009  to  Mon May  4 02:05:55.972 2009   ( 59.30) secs
                     guiding was not stable within 6 cycles

 232  FAILED    GCS        guidethread.warning                                           Mon May  4 02:14:31.406 2009  to  Mon May  4 02:14:31.406 2009   (  0.00) secs
                     no guide star found

 233  FAILED    PMC        VxInterface.close                                             Mon May  4 02:33:55.776 2009  to  Mon May  4 02:33:55.776 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 234  FAILED    PMC        VxInterface.lengthError                                       Mon May  4 02:33:55.723 2009  to  Mon May  4 02:33:55.723 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 235  STARTUP   GCS        startup                                                       Mon May  4 02:46:45.360 2009  to  Mon May  4 02:46:45.360 2009   (  0.00) secs
                     left GCS subsystem started

 236  FAILED    GCS        command.getFullGuideImage                                     Mon May  4 02:56:16.604 2009  to  Mon May  4 02:56:16.734 2009   (  0.13) secs
                     request to AzCam server for a full CCD readout failed

 237  FAILED    GCS        command.getFullGuideImage                                     Mon May  4 02:56:28.751 2009  to  Mon May  4 02:56:28.849 2009   (  0.10) secs
                     request to AzCam server for a full CCD readout failed

 238  FAILED    IIF        command.preset.(GUIDE)                                        Mon May  4 03:34:01.941 2009  to  Mon May  4 03:35:31.503 2009   ( 89.56) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 239  FAILED    GCS        command.autoAcquireGuidestar                                  Mon May  4 03:34:34.146 2009  to  Mon May  4 03:35:31.152 2009   ( 57.01) secs
                     guiding was not stable within 6 cycles

 240  FAILED    GCS        interface.azcam.guider.readout                                Mon May  4 04:09:30.308 2009  to  Mon May  4 04:09:44.302 2009   ( 13.99) secs
                     timeout occured waiting for a guide image

 241  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Mon May  4 04:17:24.557 2009  to  Mon May  4 04:17:24.557 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

**********************************************************
    Reporting period ending:   Mon May  4 05:59:53.186 2009
********************************************************************************************************