You are here: Foswiki>Software Web>TCSSWReportFile_090423 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Apr 23 2009 to Apr 24 2009
 
    Reporting period beginning:   Thu Apr 23 18:25:00.410 2009
    Reporting period ending:      Fri Apr 24 06:09:55.215 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   10.32    6.31    0.00   25.63    58.8 %         34         20         14           
                                                                      11.92    8.87    0.05   25.63

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:12:06.258 2009  to  Thu Apr 23 19:12:30.242 2009   ( 23.98) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:12:06.262 2009  to  Thu Apr 23 19:12:07.163 2009   (  0.90) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:31.831 2009  to  Thu Apr 23 19:14:32.459 2009   (  0.63) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   4  SEQERROR  IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:31.828 2009  to  Thu Apr 23 19:14:42.100 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at bentGregorianFront focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:42.100 2009  to  Thu Apr 23 19:14:43.767 2009   (  1.67) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:42.106 2009  to  Thu Apr 23 19:14:42.826 2009   (  0.72) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   7  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:43.887 2009  to  Thu Apr 23 19:14:45.514 2009   (  1.63) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   8  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:43.890 2009  to  Thu Apr 23 19:14:44.591 2009   (  0.70) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   9  SEQERROR  IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:56.416 2009  to  Thu Apr 23 19:14:56.416 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  10  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:57.550 2009  to  Thu Apr 23 19:14:59.111 2009   (  1.56) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  11  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:57.553 2009  to  Thu Apr 23 19:14:58.236 2009   (  0.68) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  12  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:15:07.311 2009  to  Thu Apr 23 19:15:08.761 2009   (  1.45) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  13  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:15:07.317 2009  to  Thu Apr 23 19:15:07.883 2009   (  0.57) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  14  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 21:54:23.688 2009  to  Thu Apr 23 21:54:24.973 2009   (  1.28) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  15  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 21:55:59.216 2009  to  Thu Apr 23 21:56:00.514 2009   (  1.30) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    5.03   16.47   13.34   26.03   100.0 %          6          6                      
                                                                       5.03   16.47   13.34   26.03
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.60    3.16    2.07    3.66   100.0 %          6          6                      
                                                                       0.60    3.16    2.07    3.66
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   70.41   81.22   18.57  248.14    94.7 %         19         16          1                 abort =     1
                                                                      70.78   85.13   25.09  248.14
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   37.30   66.09   37.95  172.90    91.9 %         37         19          3         14
                                                                      30.71   62.08   37.95  167.76
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    8.60    5.49    1.05   43.13    98.2 %         56         55                      
                                                                       8.60    5.49    1.05   43.13
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   39.11   18.44    2.07  154.33   100.0 %         52         52                      
                                                                      39.11   18.44    2.07  154.33

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  SEQERROR  IIF        command.preset.(ACTIVE)                                       Thu Apr 23 20:56:44.074 2009  to  Thu Apr 23 22:25:08.324 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACTIVE from IIF

   2  SEQERROR  IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 21:03:24.384 2009  to  Thu Apr 23 21:09:44.113 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF

   3  SEQERROR  IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 21:09:44.113 2009  to  Thu Apr 23 22:02:20.497 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF

   4  STARTUP   IIF        startup                                                       Thu Apr 23 21:48:36.021 2009  to  Thu Apr 23 21:48:36.021 2009   (  0.00) secs
                     IIF subsystem started

   5  FAILED    IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 22:05:00.055 2009  to  Thu Apr 23 22:05:18.630 2009   ( 18.57) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: IIF Preset command aborted for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

   6  SEQERROR  IIF        command.preset.elevationWait                                  Thu Apr 23 22:05:17.417 2009  to  Thu Apr 23 22:06:12.258 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for left IRTC

   7  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 23 22:25:08.324 2009  to  Thu Apr 23 22:28:01.222 2009   (172.90) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   8  STARTUP   IIF        startup                                                       Thu Apr 23 23:04:45.941 2009  to  Thu Apr 23 23:04:45.941 2009   (  0.00) secs
                     IIF subsystem started

   9  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 24 01:36:44.097 2009  to  Fri Apr 24 01:37:40.085 2009   ( 55.99) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 51
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  10  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 24 01:38:38.099 2009  to  Fri Apr 24 01:39:23.675 2009   ( 45.58) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3221                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6426                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      49                      
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 14           
     hydraulicBearing.badPMCData. . . . . . . . . . . . . . . . . .                  7           
     weatherStation.noWeatherData . . . . . . . . . . . . . . . . .                  1           

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:29.854 2009  to  Thu Apr 23 21:49:29.854 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:29.908 2009  to  Thu Apr 23 21:49:29.908 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:40.001 2009  to  Thu Apr 23 21:49:40.001 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   4  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:40.053 2009  to  Thu Apr 23 21:49:40.053 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   5  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:50.202 2009  to  Thu Apr 23 21:49:50.202 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:50.149 2009  to  Thu Apr 23 21:49:50.149 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:00.293 2009  to  Thu Apr 23 21:50:00.293 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:00.338 2009  to  Thu Apr 23 21:50:00.338 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   9  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:10.476 2009  to  Thu Apr 23 21:50:10.476 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:10.424 2009  to  Thu Apr 23 21:50:10.424 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  11  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:20.604 2009  to  Thu Apr 23 21:50:20.604 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  12  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:20.656 2009  to  Thu Apr 23 21:50:20.656 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  13  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:30.801 2009  to  Thu Apr 23 21:50:30.801 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:30.749 2009  to  Thu Apr 23 21:50:30.749 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:05:40.284 2009  to  Thu Apr 23 23:05:40.284 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        weatherStation.noWeatherData                                  Thu Apr 23 23:05:50.817 2009  to  Thu Apr 23 23:05:50.817 2009   (  0.00) secs
                     Stale or no data being received from SMT.

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:05:52.545 2009  to  Thu Apr 23 23:05:52.545 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  18  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:03.361 2009  to  Thu Apr 23 23:06:03.361 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  19  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:14.063 2009  to  Thu Apr 23 23:06:14.063 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  20  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:24.741 2009  to  Thu Apr 23 23:06:24.741 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  21  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:36.189 2009  to  Thu Apr 23 23:06:36.189 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  22  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:46.773 2009  to  Thu Apr 23 23:06:46.773 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest

   1  STARTUP   ENV        startup                                                       Thu Apr 23 21:49:16.077 2009  to  Thu Apr 23 21:49:16.077 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

   2  SHUTDOWN  ENV        command.shutdown                                              Thu Apr 23 21:49:20.933 2009  to  Thu Apr 23 21:49:20.933 2009   (  0.00) secs
                     ENV shutdown command started

   3  SHUTDOWN  ENV        command.shutdown                                              Thu Apr 23 21:49:21.171 2009  to  Thu Apr 23 21:49:21.171 2009   (  0.00) secs
                     Env shutdown command complete

   4  SHUTDOWN  ENV        shutdown                                                      Thu Apr 23 21:49:21.224 2009  to  Thu Apr 23 21:49:21.224 2009   (  0.00) secs
                     ENV subsystem shut down
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    6.06   13.49    0.00   27.61    97.2 %         36         34          1          3
                                                                       5.67   13.88    0.00   27.61
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    2.02    0.46    0.00   12.24    97.1 %         36         68          2           
                                                                       0.16    0.12    0.00    0.79
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    0.01    8.44    8.43    8.45   100.0 %          2          2                      
                                                                       0.01    8.44    8.43    8.45
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         13                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getEffectiveGuideRate. . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getMaximumGuideRate. . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         25                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    0.51    7.98    7.22    8.45   100.0 %          6          6                      
                                                                       0.51    7.98    7.22    8.45
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.02    0.14    0.10    0.15   100.0 %          6          6                      
                                                                       0.02    0.14    0.10    0.15
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    0.00    4.88    4.88    4.89   100.0 %          6          6                      
                                                                       0.00    4.88    4.88    4.89
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    4.06    2.73    0.09   11.49   100.0 %         12         12                      
                                                                       4.06    2.73    0.09   11.49
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    7.74   19.82   13.83   44.95   100.0 %         56         56                      
                                                                       7.74   19.82   13.83   44.95
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         24                                 
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.03    0.07    0.05    0.18   100.0 %         34         34                      
                                                                       0.03    0.07    0.05    0.18
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.02    0.06    0.05    0.12   100.0 %         16         16                      
                                                                       0.02    0.06    0.05    0.12
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    1.32    1.02    0.16    7.40    45.1 %         71         32                      
                                                                       1.32    1.02    0.16    7.40
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    1.08    0.67    0.00    6.02    97.0 %         33         33          1           
                                                                       0.53    0.51    0.00    1.95
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    3.16    9.24    6.60   23.23   100.0 %         62         62                      
                                                                       3.16    9.24    6.60   23.23
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.32    3.40    0.68    7.99    98.3 %       1587       1560                        interrupted =    27
                                                                       1.32    3.40    0.68    7.99
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    3.95   31.22   17.33   32.57    86.4 %        154        133                        interrupted =    20
                                                                       3.95   31.22   17.33   32.57
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.05    0.20    0.15    0.35   100.0 %         62         62                      
                                                                       0.05    0.20    0.15    0.35
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .   15.07    0.85    0.15  524.69   100.0 %       1466       1466                        interrupted =     6
                                                                      15.07    0.85    0.15  524.69
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.52    2.10    1.18    3.50   100.0 %         34         34                      
                                                                       0.52    2.10    1.18    3.50
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   50.98   22.12    8.44  541.28   100.0 %        113        113                      
                                                                      50.98   22.12    8.44  541.28
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.81    7.59    5.82    9.55    90.0 %        130        117                      
                                                                       0.81    7.59    5.82    9.55

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .      34                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 19        450
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .      34                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .      33                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .      33                      
     wfsthread.warning. . . . . . . . . . . . . . . . . . . . . . .                             1

GCS Events of Interest

   1  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:47.914 2009  to  Thu Apr 23 20:53:47.914 2009   (  0.00) secs
                     no guide star found

   2  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:53.517 2009  to  Thu Apr 23 20:53:53.517 2009   (  0.00) secs
                     no guide star found

   3  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:59.048 2009  to  Thu Apr 23 20:53:59.048 2009   (  0.00) secs
                     no guide star found

   4  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:04.552 2009  to  Thu Apr 23 20:54:04.552 2009   (  0.00) secs
                     no guide star found

   5  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:10.090 2009  to  Thu Apr 23 20:54:10.090 2009   (  0.00) secs
                     no guide star found

   6  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:44.884 2009  to  Thu Apr 23 20:54:44.884 2009   (  0.00) secs
                     no guide star found

   7  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:50.365 2009  to  Thu Apr 23 20:54:50.365 2009   (  0.00) secs
                     no guide star found

   8  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:55.862 2009  to  Thu Apr 23 20:54:55.862 2009   (  0.00) secs
                     no guide star found

   9  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:01.501 2009  to  Thu Apr 23 20:55:01.501 2009   (  0.00) secs
                     no guide star found

  10  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:07.458 2009  to  Thu Apr 23 20:55:07.458 2009   (  0.00) secs
                     no guide star found

  11  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:12.983 2009  to  Thu Apr 23 20:55:12.983 2009   (  0.00) secs
                     no guide star found

  12  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:18.496 2009  to  Thu Apr 23 20:55:18.496 2009   (  0.00) secs
                     no guide star found

  13  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:46.881 2009  to  Thu Apr 23 20:55:46.881 2009   (  0.00) secs
                     no guide star found

  14  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:52.427 2009  to  Thu Apr 23 20:55:52.427 2009   (  0.00) secs
                     no guide star found

  15  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:57.819 2009  to  Thu Apr 23 20:55:57.819 2009   (  0.00) secs
                     no guide star found

  16  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:03.332 2009  to  Thu Apr 23 20:56:03.332 2009   (  0.00) secs
                     no guide star found

  17  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:09.037 2009  to  Thu Apr 23 20:56:09.037 2009   (  0.00) secs
                     no guide star found

  18  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:37.537 2009  to  Thu Apr 23 20:56:37.537 2009   (  0.00) secs
                     no guide star found

  19  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:42.979 2009  to  Thu Apr 23 20:56:42.979 2009   (  0.00) secs
                     no guide star found

  20  SHUTDOWN  GCS        command.shutdown                                              Thu Apr 23 21:02:14.674 2009  to  Thu Apr 23 21:02:14.674 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  21  SHUTDOWN  GCS        command.shutdown                                              Thu Apr 23 21:02:15.897 2009  to  Thu Apr 23 21:02:15.897 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  22  STARTUP   GCS        startup                                                       Thu Apr 23 21:02:23.077 2009  to  Thu Apr 23 21:02:23.077 2009   (  0.00) secs
                     left GCS subsystem started

  23  STARTUP   GCS        startup                                                       Thu Apr 23 21:49:38.903 2009  to  Thu Apr 23 21:49:38.903 2009   (  0.00) secs
                     left GCS subsystem started

  24  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 23 22:27:48.740 2009  to  Thu Apr 23 22:28:00.978 2009   ( 12.24) secs
                     couldn''t find a star in any GS location.

  25  STARTUP   GCS        startup                                                       Thu Apr 23 23:06:05.414 2009  to  Thu Apr 23 23:06:05.414 2009   (  0.00) secs
                     left GCS subsystem started

  26  FAILED    GCS        command.stopWFsensing                                         Thu Apr 23 23:34:47.095 2009  to  Thu Apr 23 23:34:53.119 2009   (  6.02) secs
                     WFS loop didn''t stop within timeout.

  27  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr 24 01:37:39.587 2009  to  Fri Apr 24 01:37:39.587 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

  28  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 24 01:39:11.353 2009  to  Fri Apr 24 01:39:23.352 2009   ( 12.00) secs
                     couldn''t find a star in any GS location.
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      37                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       6                      

LSS Events of Interest

   1  SHUTDOWN  LSS        shutdown                                                      Thu Apr 23 21:12:16.188 2009  to  Thu Apr 23 21:12:16.188 2009   (  0.00) secs
                     The LSS was shut down.

   2  STARTUP   LSS        startup                                                       Thu Apr 23 21:48:30.921 2009  to  Thu Apr 23 21:48:30.921 2009   (  0.00) secs
                     The LSS was started.

   3  SHUTDOWN  LSS        shutdown                                                      Thu Apr 23 22:49:16.290 2009  to  Thu Apr 23 22:49:16.290 2009   (  0.00) secs
                     The LSS was shut down.

   4  STARTUP   LSS        startup                                                       Thu Apr 23 23:04:40.650 2009  to  Thu Apr 23 23:04:40.650 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      44                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           222
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      77                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      10                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            11
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             4
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      91                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      74                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.MEncoders.earlyFiducial. . . . . . . . . . . . . . . . .                             1
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             2
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      28                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.resetSerdes . . . . . . . . . . . . . . . . . .                             2
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      87                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  9           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     112                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      77                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      56                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      61                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     115                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     131                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1034                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     336                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  2           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 18:37:30.721 2009  to  Thu Apr 23 18:37:30.721 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 18:37:30.724 2009  to  Thu Apr 23 18:37:30.724 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Thu Apr 23 18:37:30.818 2009  to  Thu Apr 23 18:37:30.818 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.829 2009  to  Thu Apr 23 18:37:31.829 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.830 2009  to  Thu Apr 23 18:37:31.830 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.830 2009  to  Thu Apr 23 18:37:31.830 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.831 2009  to  Thu Apr 23 18:37:31.831 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.831 2009  to  Thu Apr 23 18:37:31.831 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.832 2009  to  Thu Apr 23 18:37:31.832 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.832 2009  to  Thu Apr 23 18:37:31.832 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.833 2009  to  Thu Apr 23 18:37:31.833 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Thu Apr 23 18:41:16.892 2009  to  Thu Apr 23 18:41:16.892 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.266 2009  to  Thu Apr 23 19:28:02.266 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916265575e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.747256916265575e+09 seq=0

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.267 2009  to  Thu Apr 23 19:28:02.267 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916266599e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747256916266599e+09 seq=0

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.268 2009  to  Thu Apr 23 19:28:02.268 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916242118e+09 but t0 of the LFBG target polynomial is 0.000000000000000e+00. Difference= 4.747256916242118e+09 seq=0

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 21:12:18.817 2009  to  Thu Apr 23 21:12:18.817 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 21:12:18.857 2009  to  Thu Apr 23 21:12:18.857 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  18  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 23 21:12:19.906 2009  to  Thu Apr 23 21:12:19.906 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.321 2009  to  Thu Apr 23 22:02:21.321 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175319629e+09 but t0 of the AZ target polynomial is 4.747263171806000e+09. Difference= 3.003513628959656e+03 seq=243127

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.323 2009  to  Thu Apr 23 22:02:21.323 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175321654e+09 but t0 of the EL target polynomial is 4.747263171806000e+09. Difference= 3.003515654563904e+03 seq=243127

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.324 2009  to  Thu Apr 23 22:02:21.324 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175276394e+09 but t0 of the LFBG target polynomial is 4.747263171806000e+09. Difference= 3.003470394134521e+03 seq=243127

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 22:49:17.356 2009  to  Thu Apr 23 22:49:17.356 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 22:49:17.356 2009  to  Thu Apr 23 22:49:17.356 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  24  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 23 22:49:18.346 2009  to  Thu Apr 23 22:49:18.346 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.734 2009  to  Thu Apr 23 23:14:12.734 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486732409e+09 but t0 of the AZ target polynomial is 4.747268990307000e+09. Difference= 1.496425408363342e+03 seq=72272

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.735 2009  to  Thu Apr 23 23:14:12.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486733920e+09 but t0 of the EL target polynomial is 4.747268990307000e+09. Difference= 1.496426919937134e+03 seq=72272

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.735 2009  to  Thu Apr 23 23:14:12.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486639170e+09 but t0 of the LFBG target polynomial is 4.747268990307000e+09. Difference= 1.496332169532776e+03 seq=66431
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    4.57    8.46    2.25   44.02   100.0 %        186        186                      
                                                                       4.57    8.46    2.25   44.02
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.34    3.17    2.56    3.76    94.5 %         55         52                      
                                                                       0.34    3.17    2.56    3.76
     side[0].tertiary_mirror.getfocalstationcount.command . . . . .    0.00    0.06    0.06    0.06   100.0 %          3          3                      
                                                                       0.00    0.06    0.06    0.06
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    4.15   21.89   11.00   24.22    60.0 %         15          9                      
                                                                       4.15   21.89   11.00   24.22

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                            11
     side[0].tertiary_mirror.movefocalstation.failed. . . . . . . .                  6           

OSS Events of Interest

   1  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:33.128 2009  to  Thu Apr 23 19:14:43.438 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

   2  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:43.438 2009  to  Thu Apr 23 19:14:45.246 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

   3  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:43.491 2009  to  Thu Apr 23 19:14:43.491 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

   4  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:45.300 2009  to  Thu Apr 23 19:14:45.300 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

   5  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:58.897 2009  to  Thu Apr 23 19:14:58.897 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

   6  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:58.844 2009  to  Thu Apr 23 19:15:08.495 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

   7  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:15:08.495 2009  to  Thu Apr 23 19:24:40.370 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

   8  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:15:08.547 2009  to  Thu Apr 23 19:15:08.547 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

   9  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 20:57:04.905 2009  to  Thu Apr 23 21:03:42.548 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  10  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 21:03:42.548 2009  to  Thu Apr 23 21:10:30.770 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  11  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 21:10:30.770 2009  to  Thu Apr 23 22:02:44.406 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  12  STARTUP   OSS        startup                                                       Thu Apr 23 21:49:07.087 2009  to  Thu Apr 23 21:49:07.087 2009   (  0.00) secs
                     The oss was started.

  13  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 21:54:24.754 2009  to  Thu Apr 23 21:55:35.290 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  14  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 21:54:24.808 2009  to  Thu Apr 23 21:54:24.808 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  15  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 21:56:00.301 2009  to  Thu Apr 23 21:56:43.854 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  16  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 21:56:00.354 2009  to  Thu Apr 23 21:56:00.354 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  17  STARTUP   OSS        startup                                                       Thu Apr 23 23:05:38.890 2009  to  Thu Apr 23 23:05:38.890 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.02    0.06    0.04    0.17   100.0 %         62         62                      
                                                                       0.02    0.06    0.04    0.17
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.04    0.28   100.0 %       1466       1466                      
                                                                       0.01    0.05    0.04    0.28
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.53    1.95    1.05    3.38   100.0 %         34         34                        largeUpdate =    31
                                                                       0.53    1.95    1.05    3.38
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         26         26                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.04    0.07   100.0 %         80         80                      
                                                                       0.00    0.05    0.04    0.07
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.02    0.06    0.05    0.15   100.0 %         56         56                      
                                                                       0.02    0.06    0.05    0.15
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.06    0.41    0.22    0.46   100.0 %         15         15                      
                                                                       0.06    0.41    0.22    0.46
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.53    0.31    0.87   100.0 %         56         56                      
                                                                       0.20    0.53    0.31    0.87
 *** telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.03    0.03    0.00    0.08    60.0 %         30                    12           
                                                                       0.02    0.06    0.01    0.08

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.330 2009  to  Thu Apr 23 19:12:06.399 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.399 2009  to  Thu Apr 23 19:12:06.414 2009   (  0.01) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.746 2009  to  Thu Apr 23 19:12:06.746 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   4  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:31.891 2009  to  Thu Apr 23 19:14:31.966 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   5  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:31.966 2009  to  Thu Apr 23 19:14:32.002 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:32.076 2009  to  Thu Apr 23 19:14:32.076 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.239 2009  to  Thu Apr 23 19:14:42.279 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   8  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.169 2009  to  Thu Apr 23 19:14:42.239 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   9  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.351 2009  to  Thu Apr 23 19:14:42.351 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  10  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:43.950 2009  to  Thu Apr 23 19:14:44.019 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  11  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:44.019 2009  to  Thu Apr 23 19:14:44.062 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  12  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:44.128 2009  to  Thu Apr 23 19:14:44.128 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  13  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.614 2009  to  Thu Apr 23 19:14:57.680 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  14  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.680 2009  to  Thu Apr 23 19:14:57.723 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  15  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.793 2009  to  Thu Apr 23 19:14:57.793 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  16  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.380 2009  to  Thu Apr 23 19:15:07.446 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  17  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.446 2009  to  Thu Apr 23 19:15:07.489 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  18  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.557 2009  to  Thu Apr 23 19:15:07.557 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  19  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:24:39.362 2009  to  Thu Apr 23 19:24:39.428 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  20  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:24:39.571 2009  to  Thu Apr 23 19:24:39.571 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  21  STARTUP   PCS        startup                                                       Thu Apr 23 21:49:00.413 2009  to  Thu Apr 23 21:49:00.413 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

  22  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:53:53.374 2009  to  Thu Apr 23 21:53:53.498 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  23  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:53:53.606 2009  to  Thu Apr 23 21:53:53.606 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  24  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:54:23.757 2009  to  Thu Apr 23 21:54:23.826 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  25  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:54:23.967 2009  to  Thu Apr 23 21:54:23.967 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  26  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:55:34.327 2009  to  Thu Apr 23 21:55:34.458 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  27  STARTUP   PCS        startup                                                       Thu Apr 23 23:05:33.017 2009  to  Thu Apr 23 23:05:33.017 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.01    2.06    2.05    2.12   100.0 %         98         98                      
                                                                       0.01    2.06    2.05    2.12
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.06    5.06    5.06   100.0 %          1          1                      
                                                                       0.00    5.06    5.06    5.06
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.23    0.53    0.35    0.79   100.0 %          3          3                      
                                                                       0.23    0.53    0.35    0.79
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   15.31   11.94    2.06   68.19   100.0 %         58         58                      
                                                                      15.31   11.94    2.06   68.19

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  4           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      98                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 19           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      42                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             4
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       7                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       6                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       5                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       5                      
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       5                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  8           
     servoLoop.telemetryError . . . . . . . . . . . . . . . . . . .                  8           
     thermal.telemetryError . . . . . . . . . . . . . . . . . . . .                  8           
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            24
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                           338
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             3

PMC Events of Interest

   1  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 19:43:22.540 2009  to  Thu Apr 23 19:43:22.540 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   2  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 19:43:22.488 2009  to  Thu Apr 23 19:43:22.488 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   3  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 19:43:22.592 2009  to  Thu Apr 23 19:43:22.592 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   4  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 20:40:48.663 2009  to  Thu Apr 23 20:40:48.663 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.close                                             Thu Apr 23 20:40:48.715 2009  to  Thu Apr 23 20:40:48.715 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   6  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 21:12:14.902 2009  to  Thu Apr 23 21:12:14.902 2009   (  0.00) secs
                     left PMC subsystem shut down

   7  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:14.954 2009  to  Thu Apr 23 21:12:14.954 2009   (  0.00) secs
                     left PMC PMC closing network connection

   8  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.006 2009  to  Thu Apr 23 21:12:15.006 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

   9  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.058 2009  to  Thu Apr 23 21:12:15.058 2009   (  0.00) secs
                     left PMC Async closing network connection

  10  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.110 2009  to  Thu Apr 23 21:12:15.110 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  11  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.162 2009  to  Thu Apr 23 21:12:15.162 2009   (  0.00) secs
                     left PMC Mount closing network connection

  12  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.266 2009  to  Thu Apr 23 21:12:15.266 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  13  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.370 2009  to  Thu Apr 23 21:12:15.370 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  14  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.474 2009  to  Thu Apr 23 21:12:15.474 2009   (  0.00) secs
                     left PMC Motor closing network connection

  15  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.578 2009  to  Thu Apr 23 21:12:15.578 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  16  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.631 2009  to  Thu Apr 23 21:12:15.631 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 21:12:17.104 2009  to  Thu Apr 23 21:12:17.104 2009   (  0.00) secs
                     right PMC subsystem shut down

  18  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:17.156 2009  to  Thu Apr 23 21:12:17.156 2009   (  0.00) secs
                     right PMC PMC closing network connection

  19  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:17.208 2009  to  Thu Apr 23 21:12:17.208 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

  20  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:27.875 2009  to  Thu Apr 23 21:49:27.875 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  21  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:28.989 2009  to  Thu Apr 23 21:49:28.989 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLnAEHiL'' (Errcode: 28)

  22  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:49:31.324 2009  to  Thu Apr 23 21:49:31.324 2009   (  0.00) secs
                     left PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLE8qfMX'' (Errcode: 28)

  23  STARTUP   PMC        startup                                                       Thu Apr 23 21:49:31.476 2009  to  Thu Apr 23 21:49:31.476 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

  24  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:33.332 2009  to  Thu Apr 23 21:49:33.332 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

  25  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:52.024 2009  to  Thu Apr 23 21:49:52.024 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  26  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:53.317 2009  to  Thu Apr 23 21:49:53.317 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  27  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:54.327 2009  to  Thu Apr 23 21:49:54.327 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLdhjXqY'' (Errcode: 28)

  28  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:49:57.272 2009  to  Thu Apr 23 21:49:57.272 2009   (  0.00) secs
                     right PMC Thermal telemetry error: 3: Error writing file ''/tmp/ML0CMxr5'' (Errcode: 28)

  29  STARTUP   PMC        startup                                                       Thu Apr 23 21:49:57.377 2009  to  Thu Apr 23 21:49:57.377 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

  30  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:50:02.485 2009  to  Thu Apr 23 21:50:02.485 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

  31  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:50:22.285 2009  to  Thu Apr 23 21:50:22.285 2009   (  0.00) secs
                     left PMC Thermal telemetry error: No telemetry since telemeter registration failed.

  32  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:50:33.921 2009  to  Thu Apr 23 21:50:33.921 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  33  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:50:48.513 2009  to  Thu Apr 23 21:50:48.513 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

  34  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 22:27:30.933 2009  to  Thu Apr 23 22:27:30.933 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  35  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 22:27:30.986 2009  to  Thu Apr 23 22:27:30.986 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  36  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 22:27:31.038 2009  to  Thu Apr 23 22:27:31.038 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  37  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 22:49:16.571 2009  to  Thu Apr 23 22:49:16.571 2009   (  0.00) secs
                     left PMC subsystem shut down

  38  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.623 2009  to  Thu Apr 23 22:49:16.623 2009   (  0.00) secs
                     left PMC PMC closing network connection

  39  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.675 2009  to  Thu Apr 23 22:49:16.675 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

  40  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.728 2009  to  Thu Apr 23 22:49:16.728 2009   (  0.00) secs
                     left PMC Async closing network connection

  41  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.779 2009  to  Thu Apr 23 22:49:16.779 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  42  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.831 2009  to  Thu Apr 23 22:49:16.831 2009   (  0.00) secs
                     left PMC Mount closing network connection

  43  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.935 2009  to  Thu Apr 23 22:49:16.935 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  44  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:05:44.438 2009  to  Thu Apr 23 23:05:44.438 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  45  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:05:45.350 2009  to  Thu Apr 23 23:05:45.350 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/ML90hl6p'' (Errcode: 28)

  46  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:05:47.443 2009  to  Thu Apr 23 23:05:47.443 2009   (  0.00) secs
                     left PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLGVvGyl'' (Errcode: 28)

  47  STARTUP   PMC        startup                                                       Thu Apr 23 23:05:47.547 2009  to  Thu Apr 23 23:05:47.547 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

  48  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:05:49.308 2009  to  Thu Apr 23 23:05:49.308 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

  49  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:06:06.920 2009  to  Thu Apr 23 23:06:06.920 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  50  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:06:18.418 2009  to  Thu Apr 23 23:06:18.418 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  51  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:06:19.335 2009  to  Thu Apr 23 23:06:19.335 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLjPfYxo'' (Errcode: 28)

  52  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:06:22.299 2009  to  Thu Apr 23 23:06:22.299 2009   (  0.00) secs
                     right PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLiYURNx'' (Errcode: 28)

  53  STARTUP   PMC        startup                                                       Thu Apr 23 23:06:22.399 2009  to  Thu Apr 23 23:06:22.399 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

  54  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:06:26.978 2009  to  Thu Apr 23 23:06:26.978 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

  55  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:06:38.276 2009  to  Thu Apr 23 23:06:38.276 2009   (  0.00) secs
                     left PMC Thermal telemetry error: No telemetry since telemeter registration failed.

  56  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:07:00.495 2009  to  Thu Apr 23 23:07:00.495 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

  57  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:07:13.623 2009  to  Thu Apr 23 23:07:13.623 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

  58  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 00:32:32.594 2009  to  Fri Apr 24 00:32:32.594 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  59  FAILED    PMC        thermal.badReceive                                            Fri Apr 24 00:32:32.699 2009  to  Fri Apr 24 00:32:32.699 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  60  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 24 00:32:32.647 2009  to  Fri Apr 24 00:32:32.647 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  61  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:42.866 2009  to  Fri Apr 24 01:09:42.866 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  62  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 24 01:09:42.918 2009  to  Fri Apr 24 01:09:42.918 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

  63  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.273 2009  to  Fri Apr 24 01:09:43.273 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  64  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.629 2009  to  Fri Apr 24 01:09:43.629 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  65  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.983 2009  to  Fri Apr 24 01:09:43.983 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.76   13.53    8.13   41.40   100.0 %        113        113                      
                                                                       4.76   13.53    8.13   41.40
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    2.79    1.31    0.27   14.18   100.0 %         58         58                      
                                                                       2.79    1.31    0.27   14.18
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.13    0.09    0.04    0.54   100.0 %         30         30                      
                                                                       0.13    0.09    0.04    0.54
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.76   13.64    8.24   41.53   100.0 %        113        113                      
                                                                       4.76   13.64    8.24   41.53
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.20    4.16    0.19   29.39   100.0 %        113        113                      
                                                                       4.20    4.16    0.19   29.39
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   15.31   12.07    2.18   68.32   100.0 %         58         58                      
                                                                      15.31   12.07    2.18   68.32
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.17    0.11    0.07    2.48   100.0 %        531        531                      
                                                                       0.17    0.11    0.07    2.48
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.22    0.32    0.07    0.58   100.0 %          7          7                      
                                                                       0.22    0.32    0.07    0.58
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.39    1.67    1.25    2.05   100.0 %          4          4                      
                                                                       0.39    1.67    1.25    2.05
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.06    0.05    0.11   100.0 %         58         58                      
                                                                       0.01    0.06    0.05    0.11
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.06    0.07    0.05    0.50   100.0 %        113        113                      
                                                                       0.06    0.07    0.05    0.50
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.54    8.92    4.94   13.12   100.0 %        119        119                      
                                                                       1.54    8.92    4.94   13.12
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    4.57    8.64    2.37   44.15   100.0 %        186        186                      
                                                                       4.57    8.64    2.37   44.15
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.06    0.05    0.09   100.0 %         58         58                      
                                                                       0.01    0.06    0.05    0.09
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.34    1.48    1.19    1.91   100.0 %          4          4                      
                                                                       0.34    1.48    1.19    1.91
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.45    0.46    0.06    1.15   100.0 %          9          9                      
                                                                       0.45    0.46    0.06    1.15
     secondaryMirror.command.setGains . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.06    0.06
     secondaryMirror.command.setGlobalOffsets . . . . . . . . . . .   14.28   16.58    8.07   44.25   100.0 %         10         10                      
                                                                      14.28   16.58    8.07   44.25
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.06    0.07    0.05    0.50   100.0 %        117        117                      
                                                                       0.06    0.07    0.05    0.50
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    0.34    3.30    2.68    3.88    94.5 %         55         52                      
                                                                       0.34    3.30    2.68    3.88
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.06    0.14    0.08    0.20   100.0 %          4          4                      
                                                                       0.06    0.14    0.08    0.20
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.29    0.37    0.06    0.70   100.0 %          7          7                      
                                                                       0.29    0.37    0.06    0.70

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 20:57:04.843 2009  to  Thu Apr 23 21:03:42.488 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

   2  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 21:03:42.488 2009  to  Thu Apr 23 21:10:30.708 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

   3  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 21:10:30.708 2009  to  Thu Apr 23 22:02:44.345 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

   4  STARTUP   PSF        startup                                                       Thu Apr 23 21:49:32.756 2009  to  Thu Apr 23 21:49:32.756 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

   5  STARTUP   PSF        startup                                                       Thu Apr 23 21:49:59.993 2009  to  Thu Apr 23 21:49:59.993 2009   (  0.00) secs
                     right PSF subsystem started, version 4.33

   6  STARTUP   PSF        startup                                                       Thu Apr 23 23:05:50.476 2009  to  Thu Apr 23 23:05:50.476 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

   7  STARTUP   PSF        startup                                                       Thu Apr 23 23:06:24.864 2009  to  Thu Apr 23 23:06:24.864 2009   (  0.00) secs
                     right PSF subsystem started, version 4.33
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 18:37:30.721 2009  to  Thu Apr 23 18:37:30.721 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 18:37:30.724 2009  to  Thu Apr 23 18:37:30.724 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Thu Apr 23 18:37:30.818 2009  to  Thu Apr 23 18:37:30.818 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.829 2009  to  Thu Apr 23 18:37:31.829 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.830 2009  to  Thu Apr 23 18:37:31.830 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.830 2009  to  Thu Apr 23 18:37:31.830 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.831 2009  to  Thu Apr 23 18:37:31.831 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.831 2009  to  Thu Apr 23 18:37:31.831 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.832 2009  to  Thu Apr 23 18:37:31.832 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.832 2009  to  Thu Apr 23 18:37:31.832 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Apr 23 18:37:31.833 2009  to  Thu Apr 23 18:37:31.833 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Thu Apr 23 18:41:16.892 2009  to  Thu Apr 23 18:41:16.892 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  13  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:12:06.258 2009  to  Thu Apr 23 19:12:30.242 2009   ( 23.98) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  14  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:12:06.262 2009  to  Thu Apr 23 19:12:07.163 2009   (  0.90) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  15  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.330 2009  to  Thu Apr 23 19:12:06.399 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  16  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.399 2009  to  Thu Apr 23 19:12:06.414 2009   (  0.01) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  17  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:12:06.746 2009  to  Thu Apr 23 19:12:06.746 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  18  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:31.831 2009  to  Thu Apr 23 19:14:32.459 2009   (  0.63) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  19  SEQERROR  IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:31.828 2009  to  Thu Apr 23 19:14:42.100 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left IRTC at bentGregorianFront focus

  20  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:31.891 2009  to  Thu Apr 23 19:14:31.966 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  21  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:31.966 2009  to  Thu Apr 23 19:14:32.002 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  22  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:32.076 2009  to  Thu Apr 23 19:14:32.076 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  23  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:33.128 2009  to  Thu Apr 23 19:14:43.438 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  24  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:42.100 2009  to  Thu Apr 23 19:14:43.767 2009   (  1.67) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  25  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:42.106 2009  to  Thu Apr 23 19:14:42.826 2009   (  0.72) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  26  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.239 2009  to  Thu Apr 23 19:14:42.279 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  27  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.169 2009  to  Thu Apr 23 19:14:42.239 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  28  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:42.351 2009  to  Thu Apr 23 19:14:42.351 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  29  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:43.438 2009  to  Thu Apr 23 19:14:45.246 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  30  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:43.491 2009  to  Thu Apr 23 19:14:43.491 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  31  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:43.950 2009  to  Thu Apr 23 19:14:44.019 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  32  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:43.887 2009  to  Thu Apr 23 19:14:45.514 2009   (  1.63) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  33  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:43.890 2009  to  Thu Apr 23 19:14:44.591 2009   (  0.70) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  34  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:44.019 2009  to  Thu Apr 23 19:14:44.062 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  35  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:44.128 2009  to  Thu Apr 23 19:14:44.128 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  36  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:45.300 2009  to  Thu Apr 23 19:14:45.300 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  37  SEQERROR  IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:56.416 2009  to  Thu Apr 23 19:14:56.416 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  38  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.614 2009  to  Thu Apr 23 19:14:57.680 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  39  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:57.550 2009  to  Thu Apr 23 19:14:59.111 2009   (  1.56) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  40  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:14:57.553 2009  to  Thu Apr 23 19:14:58.236 2009   (  0.68) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  41  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.680 2009  to  Thu Apr 23 19:14:57.723 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  42  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:14:57.793 2009  to  Thu Apr 23 19:14:57.793 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  43  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:14:58.897 2009  to  Thu Apr 23 19:14:58.897 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  44  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:14:58.844 2009  to  Thu Apr 23 19:15:08.495 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  45  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.380 2009  to  Thu Apr 23 19:15:07.446 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  46  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:15:07.311 2009  to  Thu Apr 23 19:15:08.761 2009   (  1.45) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  47  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 19:15:07.317 2009  to  Thu Apr 23 19:15:07.883 2009   (  0.57) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  48  FAILED    PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.446 2009  to  Thu Apr 23 19:15:07.489 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  49  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:15:07.557 2009  to  Thu Apr 23 19:15:07.557 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  50  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 19:15:08.495 2009  to  Thu Apr 23 19:24:40.370 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  51  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 19:15:08.547 2009  to  Thu Apr 23 19:15:08.547 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  52  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:24:39.362 2009  to  Thu Apr 23 19:24:39.428 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  53  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 19:24:39.571 2009  to  Thu Apr 23 19:24:39.571 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.266 2009  to  Thu Apr 23 19:28:02.266 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916265575e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.747256916265575e+09 seq=0

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.267 2009  to  Thu Apr 23 19:28:02.267 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916266599e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747256916266599e+09 seq=0

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 19:28:02.268 2009  to  Thu Apr 23 19:28:02.268 2009   (  0.00) secs
                     MJDsec from DSP is 4.747256916242118e+09 but t0 of the LFBG target polynomial is 0.000000000000000e+00. Difference= 4.747256916242118e+09 seq=0

  57  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 19:43:22.540 2009  to  Thu Apr 23 19:43:22.540 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  58  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 19:43:22.488 2009  to  Thu Apr 23 19:43:22.488 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  59  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 19:43:22.592 2009  to  Thu Apr 23 19:43:22.592 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  60  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 20:40:48.663 2009  to  Thu Apr 23 20:40:48.663 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Thu Apr 23 20:40:48.715 2009  to  Thu Apr 23 20:40:48.715 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  62  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:47.914 2009  to  Thu Apr 23 20:53:47.914 2009   (  0.00) secs
                     no guide star found

  63  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:53.517 2009  to  Thu Apr 23 20:53:53.517 2009   (  0.00) secs
                     no guide star found

  64  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:53:59.048 2009  to  Thu Apr 23 20:53:59.048 2009   (  0.00) secs
                     no guide star found

  65  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:04.552 2009  to  Thu Apr 23 20:54:04.552 2009   (  0.00) secs
                     no guide star found

  66  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:10.090 2009  to  Thu Apr 23 20:54:10.090 2009   (  0.00) secs
                     no guide star found

  67  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:44.884 2009  to  Thu Apr 23 20:54:44.884 2009   (  0.00) secs
                     no guide star found

  68  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:50.365 2009  to  Thu Apr 23 20:54:50.365 2009   (  0.00) secs
                     no guide star found

  69  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:54:55.862 2009  to  Thu Apr 23 20:54:55.862 2009   (  0.00) secs
                     no guide star found

  70  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:01.501 2009  to  Thu Apr 23 20:55:01.501 2009   (  0.00) secs
                     no guide star found

  71  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:07.458 2009  to  Thu Apr 23 20:55:07.458 2009   (  0.00) secs
                     no guide star found

  72  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:12.983 2009  to  Thu Apr 23 20:55:12.983 2009   (  0.00) secs
                     no guide star found

  73  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:18.496 2009  to  Thu Apr 23 20:55:18.496 2009   (  0.00) secs
                     no guide star found

  74  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:46.881 2009  to  Thu Apr 23 20:55:46.881 2009   (  0.00) secs
                     no guide star found

  75  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:52.427 2009  to  Thu Apr 23 20:55:52.427 2009   (  0.00) secs
                     no guide star found

  76  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:55:57.819 2009  to  Thu Apr 23 20:55:57.819 2009   (  0.00) secs
                     no guide star found

  77  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:03.332 2009  to  Thu Apr 23 20:56:03.332 2009   (  0.00) secs
                     no guide star found

  78  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:09.037 2009  to  Thu Apr 23 20:56:09.037 2009   (  0.00) secs
                     no guide star found

  79  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:37.537 2009  to  Thu Apr 23 20:56:37.537 2009   (  0.00) secs
                     no guide star found

  80  FAILED    GCS        guidethread.warning                                           Thu Apr 23 20:56:42.979 2009  to  Thu Apr 23 20:56:42.979 2009   (  0.00) secs
                     no guide star found

  81  SEQERROR  IIF        command.preset.(ACTIVE)                                       Thu Apr 23 20:56:44.074 2009  to  Thu Apr 23 22:25:08.324 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACTIVE from IIF

  82  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 20:57:04.843 2009  to  Thu Apr 23 21:03:42.488 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  83  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 20:57:04.905 2009  to  Thu Apr 23 21:03:42.548 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  84  SHUTDOWN  GCS        command.shutdown                                              Thu Apr 23 21:02:14.674 2009  to  Thu Apr 23 21:02:14.674 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  85  SHUTDOWN  GCS        command.shutdown                                              Thu Apr 23 21:02:15.897 2009  to  Thu Apr 23 21:02:15.897 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  86  STARTUP   GCS        startup                                                       Thu Apr 23 21:02:23.077 2009  to  Thu Apr 23 21:02:23.077 2009   (  0.00) secs
                     left GCS subsystem started

  87  SEQERROR  IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 21:03:24.384 2009  to  Thu Apr 23 21:09:44.113 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF

  88  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 21:03:42.548 2009  to  Thu Apr 23 21:10:30.770 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  89  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 21:03:42.488 2009  to  Thu Apr 23 21:10:30.708 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  90  SEQERROR  IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 21:09:44.113 2009  to  Thu Apr 23 22:02:20.497 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF

  91  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Thu Apr 23 21:10:30.770 2009  to  Thu Apr 23 22:02:44.406 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  92  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Thu Apr 23 21:10:30.708 2009  to  Thu Apr 23 22:02:44.345 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  93  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 21:12:14.902 2009  to  Thu Apr 23 21:12:14.902 2009   (  0.00) secs
                     left PMC subsystem shut down

  94  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:14.954 2009  to  Thu Apr 23 21:12:14.954 2009   (  0.00) secs
                     left PMC PMC closing network connection

  95  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.006 2009  to  Thu Apr 23 21:12:15.006 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

  96  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.058 2009  to  Thu Apr 23 21:12:15.058 2009   (  0.00) secs
                     left PMC Async closing network connection

  97  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.110 2009  to  Thu Apr 23 21:12:15.110 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  98  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.162 2009  to  Thu Apr 23 21:12:15.162 2009   (  0.00) secs
                     left PMC Mount closing network connection

  99  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.266 2009  to  Thu Apr 23 21:12:15.266 2009   (  0.00) secs
                     left PMC Mirror closing network connection

 100  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.370 2009  to  Thu Apr 23 21:12:15.370 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 101  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.474 2009  to  Thu Apr 23 21:12:15.474 2009   (  0.00) secs
                     left PMC Motor closing network connection

 102  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.578 2009  to  Thu Apr 23 21:12:15.578 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

 103  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:15.631 2009  to  Thu Apr 23 21:12:15.631 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 104  SHUTDOWN  LSS        shutdown                                                      Thu Apr 23 21:12:16.188 2009  to  Thu Apr 23 21:12:16.188 2009   (  0.00) secs
                     The LSS was shut down.

 105  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 21:12:17.104 2009  to  Thu Apr 23 21:12:17.104 2009   (  0.00) secs
                     right PMC subsystem shut down

 106  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:17.156 2009  to  Thu Apr 23 21:12:17.156 2009   (  0.00) secs
                     right PMC PMC closing network connection

 107  FAILED    PMC        VxInterface.close                                             Thu Apr 23 21:12:17.208 2009  to  Thu Apr 23 21:12:17.208 2009   (  0.00) secs
                     right PMC PMCLogger closing network connection

 108  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 21:12:18.817 2009  to  Thu Apr 23 21:12:18.817 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 21:12:18.857 2009  to  Thu Apr 23 21:12:18.857 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 110  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 23 21:12:19.906 2009  to  Thu Apr 23 21:12:19.906 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 111  STARTUP   LSS        startup                                                       Thu Apr 23 21:48:30.921 2009  to  Thu Apr 23 21:48:30.921 2009   (  0.00) secs
                     The LSS was started.

 112  STARTUP   IIF        startup                                                       Thu Apr 23 21:48:36.021 2009  to  Thu Apr 23 21:48:36.021 2009   (  0.00) secs
                     IIF subsystem started

 113  STARTUP   PCS        startup                                                       Thu Apr 23 21:49:00.413 2009  to  Thu Apr 23 21:49:00.413 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

 114  STARTUP   OSS        startup                                                       Thu Apr 23 21:49:07.087 2009  to  Thu Apr 23 21:49:07.087 2009   (  0.00) secs
                     The oss was started.

 115  STARTUP   ENV        startup                                                       Thu Apr 23 21:49:16.077 2009  to  Thu Apr 23 21:49:16.077 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

 116  SHUTDOWN  ENV        command.shutdown                                              Thu Apr 23 21:49:20.933 2009  to  Thu Apr 23 21:49:20.933 2009   (  0.00) secs
                     ENV shutdown command started

 117  SHUTDOWN  ENV        command.shutdown                                              Thu Apr 23 21:49:21.171 2009  to  Thu Apr 23 21:49:21.171 2009   (  0.00) secs
                     Env shutdown command complete

 118  SHUTDOWN  ENV        shutdown                                                      Thu Apr 23 21:49:21.224 2009  to  Thu Apr 23 21:49:21.224 2009   (  0.00) secs
                     ENV subsystem shut down

 119  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:27.875 2009  to  Thu Apr 23 21:49:27.875 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 120  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:28.989 2009  to  Thu Apr 23 21:49:28.989 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLnAEHiL'' (Errcode: 28)

 121  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:29.854 2009  to  Thu Apr 23 21:49:29.854 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 122  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:29.908 2009  to  Thu Apr 23 21:49:29.908 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 123  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:49:31.324 2009  to  Thu Apr 23 21:49:31.324 2009   (  0.00) secs
                     left PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLE8qfMX'' (Errcode: 28)

 124  STARTUP   PMC        startup                                                       Thu Apr 23 21:49:31.476 2009  to  Thu Apr 23 21:49:31.476 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

 125  STARTUP   PSF        startup                                                       Thu Apr 23 21:49:32.756 2009  to  Thu Apr 23 21:49:32.756 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

 126  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:33.332 2009  to  Thu Apr 23 21:49:33.332 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 127  STARTUP   GCS        startup                                                       Thu Apr 23 21:49:38.903 2009  to  Thu Apr 23 21:49:38.903 2009   (  0.00) secs
                     left GCS subsystem started

 128  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:40.001 2009  to  Thu Apr 23 21:49:40.001 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 129  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:40.053 2009  to  Thu Apr 23 21:49:40.053 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 130  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:49:50.202 2009  to  Thu Apr 23 21:49:50.202 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 131  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:49:50.149 2009  to  Thu Apr 23 21:49:50.149 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 132  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:52.024 2009  to  Thu Apr 23 21:49:52.024 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

 133  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:49:53.317 2009  to  Thu Apr 23 21:49:53.317 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 134  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:49:54.327 2009  to  Thu Apr 23 21:49:54.327 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLdhjXqY'' (Errcode: 28)

 135  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:49:57.272 2009  to  Thu Apr 23 21:49:57.272 2009   (  0.00) secs
                     right PMC Thermal telemetry error: 3: Error writing file ''/tmp/ML0CMxr5'' (Errcode: 28)

 136  STARTUP   PMC        startup                                                       Thu Apr 23 21:49:57.377 2009  to  Thu Apr 23 21:49:57.377 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

 137  STARTUP   PSF        startup                                                       Thu Apr 23 21:49:59.993 2009  to  Thu Apr 23 21:49:59.993 2009   (  0.00) secs
                     right PSF subsystem started, version 4.33

 138  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:00.293 2009  to  Thu Apr 23 21:50:00.293 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 139  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:00.338 2009  to  Thu Apr 23 21:50:00.338 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 140  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 21:50:02.485 2009  to  Thu Apr 23 21:50:02.485 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 141  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:10.476 2009  to  Thu Apr 23 21:50:10.476 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 142  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:10.424 2009  to  Thu Apr 23 21:50:10.424 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 143  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:20.604 2009  to  Thu Apr 23 21:50:20.604 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 144  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:20.656 2009  to  Thu Apr 23 21:50:20.656 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 145  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:50:22.285 2009  to  Thu Apr 23 21:50:22.285 2009   (  0.00) secs
                     left PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 146  FAILED    ECS        hydraulicBearing.badPMCData                                   Thu Apr 23 21:50:30.801 2009  to  Thu Apr 23 21:50:30.801 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 147  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 21:50:30.749 2009  to  Thu Apr 23 21:50:30.749 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 148  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 21:50:33.921 2009  to  Thu Apr 23 21:50:33.921 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

 149  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 21:50:48.513 2009  to  Thu Apr 23 21:50:48.513 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 150  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:53:53.374 2009  to  Thu Apr 23 21:53:53.498 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 151  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:53:53.606 2009  to  Thu Apr 23 21:53:53.606 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 152  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 21:54:23.688 2009  to  Thu Apr 23 21:54:24.973 2009   (  1.28) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

 153  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:54:23.757 2009  to  Thu Apr 23 21:54:23.826 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 154  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:54:23.967 2009  to  Thu Apr 23 21:54:23.967 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 155  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 21:54:24.754 2009  to  Thu Apr 23 21:55:35.290 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

 156  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 21:54:24.808 2009  to  Thu Apr 23 21:54:24.808 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

 157  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 23 21:55:34.327 2009  to  Thu Apr 23 21:55:34.458 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 158  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Apr 23 21:55:59.216 2009  to  Thu Apr 23 21:56:00.514 2009   (  1.30) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

 159  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Thu Apr 23 21:56:00.301 2009  to  Thu Apr 23 21:56:43.854 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

 160  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Thu Apr 23 21:56:00.354 2009  to  Thu Apr 23 21:56:00.354 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

 161  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.321 2009  to  Thu Apr 23 22:02:21.321 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175319629e+09 but t0 of the AZ target polynomial is 4.747263171806000e+09. Difference= 3.003513628959656e+03 seq=243127

 162  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.323 2009  to  Thu Apr 23 22:02:21.323 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175321654e+09 but t0 of the EL target polynomial is 4.747263171806000e+09. Difference= 3.003515654563904e+03 seq=243127

 163  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 22:02:21.324 2009  to  Thu Apr 23 22:02:21.324 2009   (  0.00) secs
                     MJDsec from DSP is 4.747266175276394e+09 but t0 of the LFBG target polynomial is 4.747263171806000e+09. Difference= 3.003470394134521e+03 seq=243127

 164  FAILED    IIF        command.preset.(ACQUIRE)                                      Thu Apr 23 22:05:00.055 2009  to  Thu Apr 23 22:05:18.630 2009   ( 18.57) secs
                     IIF Preset command wait for elevation started for left IRTC
                     IIF Preset alert for left IRTC mode ACQUIRE: IIF Preset command aborted for left IRTC mode ACQUIRE from IIF
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

 165  SEQERROR  IIF        command.preset.elevationWait                                  Thu Apr 23 22:05:17.417 2009  to  Thu Apr 23 22:06:12.258 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for left IRTC

 166  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 23 22:25:08.324 2009  to  Thu Apr 23 22:28:01.222 2009   (172.90) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 167  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 22:27:30.933 2009  to  Thu Apr 23 22:27:30.933 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 168  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 22:27:30.986 2009  to  Thu Apr 23 22:27:30.986 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 169  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 22:27:31.038 2009  to  Thu Apr 23 22:27:31.038 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 170  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 23 22:27:48.740 2009  to  Thu Apr 23 22:28:00.978 2009   ( 12.24) secs
                     couldn''t find a star in any GS location.

 171  SHUTDOWN  LSS        shutdown                                                      Thu Apr 23 22:49:16.290 2009  to  Thu Apr 23 22:49:16.290 2009   (  0.00) secs
                     The LSS was shut down.

 172  SHUTDOWN  PMC        shutdown                                                      Thu Apr 23 22:49:16.571 2009  to  Thu Apr 23 22:49:16.571 2009   (  0.00) secs
                     left PMC subsystem shut down

 173  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.623 2009  to  Thu Apr 23 22:49:16.623 2009   (  0.00) secs
                     left PMC PMC closing network connection

 174  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.675 2009  to  Thu Apr 23 22:49:16.675 2009   (  0.00) secs
                     left PMC PMCLogger closing network connection

 175  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.728 2009  to  Thu Apr 23 22:49:16.728 2009   (  0.00) secs
                     left PMC Async closing network connection

 176  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.779 2009  to  Thu Apr 23 22:49:16.779 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 177  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.831 2009  to  Thu Apr 23 22:49:16.831 2009   (  0.00) secs
                     left PMC Mount closing network connection

 178  FAILED    PMC        VxInterface.close                                             Thu Apr 23 22:49:16.935 2009  to  Thu Apr 23 22:49:16.935 2009   (  0.00) secs
                     left PMC Mirror closing network connection

 179  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 22:49:17.356 2009  to  Thu Apr 23 22:49:17.356 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 180  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 23 22:49:17.356 2009  to  Thu Apr 23 22:49:17.356 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 181  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 23 22:49:18.346 2009  to  Thu Apr 23 22:49:18.346 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 182  STARTUP   LSS        startup                                                       Thu Apr 23 23:04:40.650 2009  to  Thu Apr 23 23:04:40.650 2009   (  0.00) secs
                     The LSS was started.

 183  STARTUP   IIF        startup                                                       Thu Apr 23 23:04:45.941 2009  to  Thu Apr 23 23:04:45.941 2009   (  0.00) secs
                     IIF subsystem started

 184  STARTUP   PCS        startup                                                       Thu Apr 23 23:05:33.017 2009  to  Thu Apr 23 23:05:33.017 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.34

 185  STARTUP   OSS        startup                                                       Thu Apr 23 23:05:38.890 2009  to  Thu Apr 23 23:05:38.890 2009   (  0.00) secs
                     The oss was started.

 186  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:05:40.284 2009  to  Thu Apr 23 23:05:40.284 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 187  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:05:44.438 2009  to  Thu Apr 23 23:05:44.438 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 188  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:05:45.350 2009  to  Thu Apr 23 23:05:45.350 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/ML90hl6p'' (Errcode: 28)

 189  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:05:47.443 2009  to  Thu Apr 23 23:05:47.443 2009   (  0.00) secs
                     left PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLGVvGyl'' (Errcode: 28)

 190  STARTUP   PMC        startup                                                       Thu Apr 23 23:05:47.547 2009  to  Thu Apr 23 23:05:47.547 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

 191  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:05:49.308 2009  to  Thu Apr 23 23:05:49.308 2009   (  0.00) secs
                     left PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 192  STARTUP   PSF        startup                                                       Thu Apr 23 23:05:50.476 2009  to  Thu Apr 23 23:05:50.476 2009   (  0.00) secs
                     left PSF subsystem started, version 4.33

 193  FAILED    ECS        weatherStation.noWeatherData                                  Thu Apr 23 23:05:50.817 2009  to  Thu Apr 23 23:05:50.817 2009   (  0.00) secs
                     Stale or no data being received from SMT.

 194  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:05:52.545 2009  to  Thu Apr 23 23:05:52.545 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 195  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:03.361 2009  to  Thu Apr 23 23:06:03.361 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 196  STARTUP   GCS        startup                                                       Thu Apr 23 23:06:05.414 2009  to  Thu Apr 23 23:06:05.414 2009   (  0.00) secs
                     left GCS subsystem started

 197  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:06:06.920 2009  to  Thu Apr 23 23:06:06.920 2009   (  0.00) secs
                     left PMC Actuator telemetry error: No telemetry since telemeter registration failed.

 198  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:14.063 2009  to  Thu Apr 23 23:06:14.063 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 199  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:06:18.418 2009  to  Thu Apr 23 23:06:18.418 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 200  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:06:19.335 2009  to  Thu Apr 23 23:06:19.335 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: 3: Error writing file ''/tmp/MLjPfYxo'' (Errcode: 28)

 201  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:06:22.299 2009  to  Thu Apr 23 23:06:22.299 2009   (  0.00) secs
                     right PMC Thermal telemetry error: 3: Error writing file ''/tmp/MLiYURNx'' (Errcode: 28)

 202  STARTUP   PMC        startup                                                       Thu Apr 23 23:06:22.399 2009  to  Thu Apr 23 23:06:22.399 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

 203  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:24.741 2009  to  Thu Apr 23 23:06:24.741 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 204  STARTUP   PSF        startup                                                       Thu Apr 23 23:06:24.864 2009  to  Thu Apr 23 23:06:24.864 2009   (  0.00) secs
                     right PSF subsystem started, version 4.33

 205  FAILED    PMC        servoLoop.telemetryError                                      Thu Apr 23 23:06:26.978 2009  to  Thu Apr 23 23:06:26.978 2009   (  0.00) secs
                     right PMC ServoLoop telemetry error: No telemetry since telemeter registration failed.

 206  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:36.189 2009  to  Thu Apr 23 23:06:36.189 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 207  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:06:38.276 2009  to  Thu Apr 23 23:06:38.276 2009   (  0.00) secs
                     left PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 208  FAILED    ECS        instrumentCooling.badPMCData                                  Thu Apr 23 23:06:46.773 2009  to  Thu Apr 23 23:06:46.773 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 209  FAILED    PMC        actuator.telemetryError                                       Thu Apr 23 23:07:00.495 2009  to  Thu Apr 23 23:07:00.495 2009   (  0.00) secs
                     right PMC Actuator telemetry error: No telemetry since telemeter registration failed.

 210  FAILED    PMC        thermal.telemetryError                                        Thu Apr 23 23:07:13.623 2009  to  Thu Apr 23 23:07:13.623 2009   (  0.00) secs
                     right PMC Thermal telemetry error: No telemetry since telemeter registration failed.

 211  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.734 2009  to  Thu Apr 23 23:14:12.734 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486732409e+09 but t0 of the AZ target polynomial is 4.747268990307000e+09. Difference= 1.496425408363342e+03 seq=72272

 212  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.735 2009  to  Thu Apr 23 23:14:12.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486733920e+09 but t0 of the EL target polynomial is 4.747268990307000e+09. Difference= 1.496426919937134e+03 seq=72272

 213  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 23 23:14:12.735 2009  to  Thu Apr 23 23:14:12.735 2009   (  0.00) secs
                     MJDsec from DSP is 4.747270486639170e+09 but t0 of the LFBG target polynomial is 4.747268990307000e+09. Difference= 1.496332169532776e+03 seq=66431

 214  FAILED    GCS        command.stopWFsensing                                         Thu Apr 23 23:34:47.095 2009  to  Thu Apr 23 23:34:53.119 2009   (  6.02) secs
                     WFS loop didn''t stop within timeout.

 215  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 00:32:32.594 2009  to  Fri Apr 24 00:32:32.594 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 216  FAILED    PMC        thermal.badReceive                                            Fri Apr 24 00:32:32.699 2009  to  Fri Apr 24 00:32:32.699 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 217  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 24 00:32:32.647 2009  to  Fri Apr 24 00:32:32.647 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 218  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:42.866 2009  to  Fri Apr 24 01:09:42.866 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 219  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 24 01:09:42.918 2009  to  Fri Apr 24 01:09:42.918 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

 220  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.273 2009  to  Fri Apr 24 01:09:43.273 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 221  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.629 2009  to  Fri Apr 24 01:09:43.629 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 222  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 24 01:09:43.983 2009  to  Fri Apr 24 01:09:43.983 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 223  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 24 01:36:44.097 2009  to  Fri Apr 24 01:37:40.085 2009   ( 55.99) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode ACTIVE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 51
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 224  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr 24 01:37:39.587 2009  to  Fri Apr 24 01:37:39.587 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

 225  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 24 01:38:38.099 2009  to  Fri Apr 24 01:39:23.675 2009   ( 45.58) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 226  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 24 01:39:11.353 2009  to  Fri Apr 24 01:39:23.352 2009   ( 12.00) secs
                     couldn''t find a star in any GS location.

**********************************************************
    Reporting period ending:   Fri Apr 24 06:09:55.215 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback