You are here: Foswiki>Software Web>TCSSWReportFile_090422 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Apr 22 2009 to Apr 23 2009
 
    Reporting period beginning:   Wed Apr 22 18:24:08.924 2009
    Reporting period ending:      Thu Apr 23 06:10:54.099 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.08   100.0 %         67         67                      
                                                                       0.00    0.05    0.05    0.08
     command.getMultiDDEntry. . . . . . . . . . . . . . . . . . . .                                   100.0 %                                2           
                                                                                                   
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.34    0.57    0.24    1.86   100.0 %        248        248                      
                                                                       0.34    0.57    0.24    1.86
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.24    0.41    0.16    1.08   100.0 %        828        828                      
                                                                       0.24    0.41    0.16    1.08
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.51    6.44    2.52   70.66   100.0 %        243        243                      
                                                                       6.51    6.44    2.52   70.66
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.97    4.24    2.70    8.62   100.0 %        121        121                      
                                                                       0.97    4.24    2.70    8.62
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.95    3.45    2.05    7.87   100.0 %        121        121                      
                                                                       0.95    3.45    2.05    7.87
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   15.83   10.49    1.05   43.14   100.0 %         24         24                      
                                                                      15.83   10.49    1.05   43.14
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   57.61   32.74    1.05  181.40   100.0 %         23         23                      
                                                                      57.61   32.74    1.05  181.40
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   81.02   55.55    7.65  267.19    95.8 %         24         22          1          1
                                                                      82.29   57.65    7.65  267.19
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    3.79    6.56    0.64   23.87   100.0 %        180        180                      
                                                                       3.79    6.56    0.64   23.87

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             8

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 21:04:22.885 2009  to  Wed Apr 22 21:04:32.322 2009   (  9.44) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494416974537037e+04, time 5.700000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

   2  SEQERROR  IIF        command.getMultiDDEntry                                       Thu Apr 23 01:39:46.019 2009  to  Thu Apr 23 01:39:46.019 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left DIMM

   3  SEQERROR  IIF        command.getMultiDDEntry                                       Thu Apr 23 01:40:03.919 2009  to  Thu Apr 23 01:40:03.919 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left DIMM
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3500                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7000                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      49                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         28                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      23                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      30                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            42
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      12                      
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       8                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      52                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     270                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1152                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     386                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Apr 22 19:01:05.167 2009  to  Wed Apr 22 19:01:05.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Apr 22 19:01:05.171 2009  to  Wed Apr 22 19:01:05.171 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Apr 22 19:01:05.274 2009  to  Wed Apr 22 19:01:05.274 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.287 2009  to  Wed Apr 22 19:01:06.287 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.288 2009  to  Wed Apr 22 19:01:06.288 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.288 2009  to  Wed Apr 22 19:01:06.288 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.289 2009  to  Wed Apr 22 19:01:06.289 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.291 2009  to  Wed Apr 22 19:01:06.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Wed Apr 22 19:21:32.439 2009  to  Wed Apr 22 19:21:32.439 2009   (  0.00) secs
                     MJDsec from DSP is 4.747170126438996e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747170126438996e+09 seq=0
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.08    0.12    0.05    0.38   100.0 %        828        828                      
                                                                       0.08    0.12    0.05    0.38
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.09    0.22    0.11    0.46   100.0 %        248        248                      
                                                                       0.09    0.22    0.11    0.46
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.25    0.37    0.05    1.19   100.0 %        121        121                      
                                                                       0.25    0.37    0.05    1.19
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.21    0.16    0.05    0.64   100.0 %         26         26                      
                                                                       0.21    0.16    0.05    0.64
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.16    0.54    0.31    0.84   100.0 %         26         26                      
                                                                       0.16    0.54    0.31    0.84

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.99    2.92    2.05    6.06   100.0 %         66         66                      
                                                                       0.99    2.92    2.05    6.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    3.08    3.08    3.08   100.0 %          1          1                      
                                                                       0.00    3.08    3.08    3.08
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          2          2                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.03    6.28    2.05   70.18    99.4 %        473        470          3           
                                                                       7.05    6.29    2.05   70.18

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      10                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            12
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             5
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      66                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 19:28:05.170 2009  to  Wed Apr 22 19:28:07.228 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 19:28:08.807 2009  to  Wed Apr 22 19:28:13.870 2009   (  5.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 19:41:03.858 2009  to  Wed Apr 22 19:41:03.858 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

   4  FAILED    PMC        VxInterface.close                                             Wed Apr 22 19:41:03.910 2009  to  Wed Apr 22 19:41:03.910 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 20:33:15.177 2009  to  Wed Apr 22 20:33:15.177 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Wed Apr 22 20:33:15.229 2009  to  Wed Apr 22 20:33:15.229 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   7  FAILED    PMC        VxInterface.close                                             Wed Apr 22 20:55:15.027 2009  to  Wed Apr 22 20:55:15.027 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 20:55:14.975 2009  to  Wed Apr 22 20:55:14.975 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 21:04:25.004 2009  to  Wed Apr 22 21:04:32.071 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 21:21:52.130 2009  to  Wed Apr 22 21:21:52.130 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Wed Apr 22 21:21:52.183 2009  to  Wed Apr 22 21:21:52.183 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.close                                             Wed Apr 22 21:21:53.682 2009  to  Wed Apr 22 21:21:53.682 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 21:21:53.630 2009  to  Wed Apr 22 21:21:53.630 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  14  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 23:02:53.606 2009  to  Wed Apr 22 23:02:53.606 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  15  FAILED    PMC        VxInterface.close                                             Wed Apr 22 23:02:53.658 2009  to  Wed Apr 22 23:02:53.658 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  16  FAILED    PMC        VxInterface.close                                             Wed Apr 22 23:48:56.140 2009  to  Wed Apr 22 23:48:56.140 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 23:48:56.089 2009  to  Wed Apr 22 23:48:56.089 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 00:04:23.747 2009  to  Thu Apr 23 00:04:23.747 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Thu Apr 23 00:04:23.800 2009  to  Thu Apr 23 00:04:23.800 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.close                                             Thu Apr 23 01:06:23.534 2009  to  Thu Apr 23 01:06:23.534 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 01:06:23.482 2009  to  Thu Apr 23 01:06:23.482 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  22  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 01:44:40.655 2009  to  Thu Apr 23 01:44:40.655 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  23  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 01:44:40.711 2009  to  Thu Apr 23 01:44:40.711 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  24  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 01:44:40.763 2009  to  Thu Apr 23 01:44:40.763 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  25  FAILED    PMC        VxInterface.close                                             Thu Apr 23 01:57:51.565 2009  to  Thu Apr 23 01:57:51.565 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 01:57:51.513 2009  to  Thu Apr 23 01:57:51.513 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.adjustPointing . . . . . . . . . . . . . . . . . . . .   13.27    9.77    0.00   38.47   100.0 %          8          8                      
                                                                      13.68   11.17    0.50   38.47
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.78    6.31    0.41   23.63   100.0 %        180        180                      
                                                                       3.78    6.31    0.41   23.63
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         48         48                      
                                                                       0.00    0.05    0.05    0.06
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    6.51    6.30    2.40   70.52   100.0 %        243        243                      
                                                                       6.51    6.30    2.40   70.52
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.78    6.42    0.51   23.74   100.0 %        180        180                      
                                                                       3.78    6.42    0.51   23.74
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.92    6.41    0.19   42.51   100.0 %        182        182                      
                                                                       4.92    6.41    0.19   42.51
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.03    6.41    2.18   70.30    99.4 %        473        470          3           
                                                                       7.05    6.42    2.18   70.30
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          2          2                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    3.23    3.23    3.23   100.0 %          1          1                      
                                                                       0.00    3.23    3.23    3.23
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.06    0.10    0.07    0.52   100.0 %        102        102                      
                                                                       0.06    0.10    0.07    0.52
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00    5.58    5.58    5.58     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    6.51    6.19    2.29   70.41   100.0 %        243        243                      
                                                                       6.51    6.19    2.29   70.41
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.02    0.07    0.06    0.09   100.0 %          2          2                      
                                                                       0.02    0.07    0.06    0.09
     primaryMirror.command.setPointingOffsets . . . . . . . . . . .   10.38   13.10    4.31   38.36    88.9 %          9          8          1           
                                                                      10.65   14.08    4.31   38.36
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.05    0.13   100.0 %        182        182                      
                                                                       0.01    0.06    0.05    0.13

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                839           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Wed Apr 22 19:28:01.768 2009  to  Wed Apr 22 19:28:07.351 2009   (  5.58) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 19:28:05.109 2009  to  Wed Apr 22 19:28:07.295 2009   (  2.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Wed Apr 22 19:28:08.693 2009  to  Wed Apr 22 19:28:13.993 2009   (  5.30) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 19:28:08.746 2009  to  Wed Apr 22 19:28:13.935 2009   (  5.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:25.888 2009  to  Wed Apr 22 19:54:25.888 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:26.144 2009  to  Wed Apr 22 19:54:26.144 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:34.092 2009  to  Wed Apr 22 19:54:34.092 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

   8  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:34.346 2009  to  Wed Apr 22 19:54:34.346 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

   9  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:37.635 2009  to  Wed Apr 22 19:54:37.635 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:37.890 2009  to  Wed Apr 22 19:54:37.890 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:56.967 2009  to  Wed Apr 22 19:54:56.967 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:57.222 2009  to  Wed Apr 22 19:54:57.222 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.330 2009  to  Wed Apr 22 19:54:58.330 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  14  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.585 2009  to  Wed Apr 22 19:54:58.585 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  15  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.839 2009  to  Wed Apr 22 19:54:58.839 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  16  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:59.904 2009  to  Wed Apr 22 19:54:59.904 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:00.158 2009  to  Wed Apr 22 19:55:00.158 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:04.258 2009  to  Wed Apr 22 19:55:04.258 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.3962727e-04 -3.7775561e-04 3.1013489e-03 1.5583903e-02 1.0467529e-02 -3.1614304e-03

  19  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:04.512 2009  to  Wed Apr 22 19:55:04.512 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.3962727e-04 -3.7775561e-04 3.1013489e-03 1.5583903e-02 1.0467529e-02 -3.1614304e-03

  20  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.210 2009  to  Wed Apr 22 19:55:08.210 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.464 2009  to  Wed Apr 22 19:55:08.464 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.718 2009  to  Wed Apr 22 19:55:08.718 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.973 2009  to  Wed Apr 22 19:55:08.973 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:09.228 2009  to  Wed Apr 22 19:55:09.228 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:10.090 2009  to  Wed Apr 22 19:55:10.090 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:10.345 2009  to  Wed Apr 22 19:55:10.345 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:11.216 2009  to  Wed Apr 22 19:55:11.216 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:11.470 2009  to  Wed Apr 22 19:55:11.470 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:13.548 2009  to  Wed Apr 22 19:55:13.548 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 21:04:24.940 2009  to  Wed Apr 22 21:04:32.142 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 23:02:15.006 2009  to  Wed Apr 22 23:02:24.786 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt 2.0000000e+01

  32  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 23:02:54.689 2009  to  Wed Apr 22 23:02:54.689 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt -4.0000000e+01
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Apr 22 19:01:05.167 2009  to  Wed Apr 22 19:01:05.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Apr 22 19:01:05.171 2009  to  Wed Apr 22 19:01:05.171 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Apr 22 19:01:05.274 2009  to  Wed Apr 22 19:01:05.274 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.287 2009  to  Wed Apr 22 19:01:06.287 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.288 2009  to  Wed Apr 22 19:01:06.288 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.288 2009  to  Wed Apr 22 19:01:06.288 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.289 2009  to  Wed Apr 22 19:01:06.289 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.290 2009  to  Wed Apr 22 19:01:06.290 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Apr 22 19:01:06.291 2009  to  Wed Apr 22 19:01:06.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Wed Apr 22 19:21:32.439 2009  to  Wed Apr 22 19:21:32.439 2009   (  0.00) secs
                     MJDsec from DSP is 4.747170126438996e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747170126438996e+09 seq=0

  13  FAILED    PSF        primaryMirror.command.revert                                  Wed Apr 22 19:28:01.768 2009  to  Wed Apr 22 19:28:07.351 2009   (  5.58) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 19:28:05.109 2009  to  Wed Apr 22 19:28:07.295 2009   (  2.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 19:28:05.170 2009  to  Wed Apr 22 19:28:07.228 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Wed Apr 22 19:28:08.693 2009  to  Wed Apr 22 19:28:13.993 2009   (  5.30) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 19:28:08.746 2009  to  Wed Apr 22 19:28:13.935 2009   (  5.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 19:28:08.807 2009  to  Wed Apr 22 19:28:13.870 2009   (  5.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 19:41:03.858 2009  to  Wed Apr 22 19:41:03.858 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  20  FAILED    PMC        VxInterface.close                                             Wed Apr 22 19:41:03.910 2009  to  Wed Apr 22 19:41:03.910 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  21  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:25.888 2009  to  Wed Apr 22 19:54:25.888 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:26.144 2009  to  Wed Apr 22 19:54:26.144 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:34.092 2009  to  Wed Apr 22 19:54:34.092 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

  24  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:34.346 2009  to  Wed Apr 22 19:54:34.346 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:37.635 2009  to  Wed Apr 22 19:54:37.635 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:37.890 2009  to  Wed Apr 22 19:54:37.890 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:56.967 2009  to  Wed Apr 22 19:54:56.967 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:57.222 2009  to  Wed Apr 22 19:54:57.222 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.330 2009  to  Wed Apr 22 19:54:58.330 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.585 2009  to  Wed Apr 22 19:54:58.585 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:58.839 2009  to  Wed Apr 22 19:54:58.839 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.5524368e-04 2.3785606e-04 3.1029582e-03 6.0085356e-03 5.0876617e-02 -3.2525063e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:54:59.904 2009  to  Wed Apr 22 19:54:59.904 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:00.158 2009  to  Wed Apr 22 19:55:00.158 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:04.258 2009  to  Wed Apr 22 19:55:04.258 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.3962727e-04 -3.7775561e-04 3.1013489e-03 1.5583903e-02 1.0467529e-02 -3.1614304e-03

  35  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:04.512 2009  to  Wed Apr 22 19:55:04.512 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.3962727e-04 -3.7775561e-04 3.1013489e-03 1.5583903e-02 1.0467529e-02 -3.1614304e-03

  36  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.210 2009  to  Wed Apr 22 19:55:08.210 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.464 2009  to  Wed Apr 22 19:55:08.464 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.7964535e-04 -6.3331798e-05 3.1014085e-03 -8.7890029e-04 6.2423706e-02 1.7822742e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.718 2009  to  Wed Apr 22 19:55:08.718 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:08.973 2009  to  Wed Apr 22 19:55:08.973 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -8.6402893e-04 -6.7894347e-04 3.0997396e-03 8.6964667e-03 2.2014618e-02 1.7913818e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:09.228 2009  to  Wed Apr 22 19:55:09.228 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:10.090 2009  to  Wed Apr 22 19:55:10.090 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:10.345 2009  to  Wed Apr 22 19:55:10.345 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:11.216 2009  to  Wed Apr 22 19:55:11.216 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:11.470 2009  to  Wed Apr 22 19:55:11.470 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -3.4797192e-04 -3.6045536e-04 3.0955076e-03 3.8330466e-02 5.0197601e-02 1.8153667e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Wed Apr 22 19:55:13.548 2009  to  Wed Apr 22 19:55:13.548 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.1796436e-04 -6.7101046e-04 3.2866001e-03 3.1426340e-02 2.7343750e-02 7.3308945e-03

  46  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 20:33:15.177 2009  to  Wed Apr 22 20:33:15.177 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  47  FAILED    PMC        VxInterface.close                                             Wed Apr 22 20:33:15.229 2009  to  Wed Apr 22 20:33:15.229 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  48  FAILED    PMC        VxInterface.close                                             Wed Apr 22 20:55:15.027 2009  to  Wed Apr 22 20:55:15.027 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 20:55:14.975 2009  to  Wed Apr 22 20:55:14.975 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  50  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 21:04:22.885 2009  to  Wed Apr 22 21:04:32.322 2009   (  9.44) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494416974537037e+04, time 5.700000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 21:04:24.940 2009  to  Wed Apr 22 21:04:32.142 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 21:04:25.004 2009  to  Wed Apr 22 21:04:32.071 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 21:21:52.130 2009  to  Wed Apr 22 21:21:52.130 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        VxInterface.close                                             Wed Apr 22 21:21:52.183 2009  to  Wed Apr 22 21:21:52.183 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.close                                             Wed Apr 22 21:21:53.682 2009  to  Wed Apr 22 21:21:53.682 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  56  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 21:21:53.630 2009  to  Wed Apr 22 21:21:53.630 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  57  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 23:02:15.006 2009  to  Wed Apr 22 23:02:24.786 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt 2.0000000e+01

  58  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 23:02:53.606 2009  to  Wed Apr 22 23:02:53.606 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  59  FAILED    PMC        VxInterface.close                                             Wed Apr 22 23:02:53.658 2009  to  Wed Apr 22 23:02:53.658 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  60  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 23:02:54.689 2009  to  Wed Apr 22 23:02:54.689 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt -4.0000000e+01

  61  FAILED    PMC        VxInterface.close                                             Wed Apr 22 23:48:56.140 2009  to  Wed Apr 22 23:48:56.140 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 23:48:56.089 2009  to  Wed Apr 22 23:48:56.089 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 00:04:23.747 2009  to  Thu Apr 23 00:04:23.747 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Thu Apr 23 00:04:23.800 2009  to  Thu Apr 23 00:04:23.800 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  65  FAILED    PMC        VxInterface.close                                             Thu Apr 23 01:06:23.534 2009  to  Thu Apr 23 01:06:23.534 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 01:06:23.482 2009  to  Thu Apr 23 01:06:23.482 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  67  SEQERROR  IIF        command.getMultiDDEntry                                       Thu Apr 23 01:39:46.019 2009  to  Thu Apr 23 01:39:46.019 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left DIMM

  68  SEQERROR  IIF        command.getMultiDDEntry                                       Thu Apr 23 01:40:03.919 2009  to  Thu Apr 23 01:40:03.919 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF GetMultiDDEntry command failed for left DIMM

  69  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 23 01:44:40.655 2009  to  Thu Apr 23 01:44:40.655 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  70  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 23 01:44:40.711 2009  to  Thu Apr 23 01:44:40.711 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  71  FAILED    PMC        thermal.badReceive                                            Thu Apr 23 01:44:40.763 2009  to  Thu Apr 23 01:44:40.763 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  72  FAILED    PMC        VxInterface.close                                             Thu Apr 23 01:57:51.565 2009  to  Thu Apr 23 01:57:51.565 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  73  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 23 01:57:51.513 2009  to  Thu Apr 23 01:57:51.513 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

**********************************************************
    Reporting period ending:   Thu Apr 23 06:10:54.099 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback