You are here: Foswiki>Software Web>TCSSWReportFile_090421 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Apr 21 2009 to Apr 22 2009
 
    Reporting period beginning:   Tue Apr 21 18:24:00.766 2009
    Reporting period ending:      Wed Apr 22 06:11:51.932 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.04    0.07   100.0 %         40         40                      
                                                                       0.00    0.05    0.04    0.07
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.37    0.69    0.24    1.77   100.0 %        248        248                      
                                                                       0.37    0.69    0.24    1.77
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.16    0.28    0.18    0.75   100.0 %         41         41                      
                                                                       0.16    0.28    0.18    0.75
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.24    5.77    2.52   27.62   100.0 %        242        242                      
                                                                       4.24    5.77    2.52   27.62
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.61    4.92    3.22   10.45   100.0 %         62         62                      
                                                                       1.61    4.92    3.22   10.45
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.80    3.69    2.05    9.07   100.0 %         62         62                      
                                                                       1.80    3.69    2.05    9.07
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   16.55   11.89    1.05   60.17    92.0 %         25         23                      
                                                                      16.55   11.89    1.05   60.17
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   47.60   26.07    2.07  151.33   100.0 %         22         22                      
                                                                      47.60   26.07    2.07  151.33
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   97.16   74.42    8.46  303.36    88.0 %         25         19          3          3    timeout =     2
                                                                      68.01   50.83    8.46  208.22
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    2.09    4.54    0.64   18.17    99.5 %        556        553          3           
                                                                       2.09    4.52    0.64   18.17
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.57    3.61    2.52    6.59   100.0 %         47         47                      
                                                                       1.57    3.61    2.52    6.59

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             8

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Tue Apr 21 20:09:31.008 2009  to  Tue Apr 21 20:14:34.366 2009   (303.36) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494313164351852e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

   2  SEQERROR  IIF        command.preset.elevationWait                                  Tue Apr 21 20:09:33.585 2009  to  Tue Apr 21 21:14:58.753 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

   3  FAILED    IIF        command.sendWavefront                                         Tue Apr 21 21:39:19.934 2009  to  Tue Apr 21 21:39:27.233 2009   (  7.30) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

   4  FAILED    IIF        command.sendWavefront                                         Wed Apr 22 04:06:52.369 2009  to  Wed Apr 22 04:06:59.327 2009   (  6.96) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

   5  FAILED    IIF        command.sendWavefront                                         Wed Apr 22 04:17:52.808 2009  to  Wed Apr 22 04:17:59.834 2009   (  7.03) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

   6  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 04:34:37.725 2009  to  Wed Apr 22 04:39:40.030 2009   (302.31) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494348239583334e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

   7  SEQERROR  IIF        command.preset.elevationWait                                  Wed Apr 22 04:34:39.179 2009  to  Wed Apr 22 04:42:35.664 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

   8  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 04:48:15.561 2009  to  Wed Apr 22 04:49:21.405 2009   ( 65.84) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494349186342592e+04, time 3.470000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3189                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7056                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    21                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     7                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     121                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         29                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            33
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            23
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      88                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           160
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .      11                      
     MCSPU.AZDrive.energizeAckFail. . . . . . . . . . . . . . . . .                  8           
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      27                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      97                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      30                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      30                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.MEncoders.earlyFiducial. . . . . . . . . . . . . . . . .                            10
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             9
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      41                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      41                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Tracker.unexpectedVelMode. . . . . . . . . . . . . . . .                  1           
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      10                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            10
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      73                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       3                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      62                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     194                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     708                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     240                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       5                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:25:42.350 2009  to  Tue Apr 21 18:25:42.350 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15100

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:26:06.178 2009  to  Tue Apr 21 18:26:06.178 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15155

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:27:10.731 2009  to  Tue Apr 21 18:27:10.731 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15223

   4  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:30:45.791 2009  to  Tue Apr 21 18:30:45.791 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15105

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:31:19.445 2009  to  Tue Apr 21 18:31:19.445 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15187

   6  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:32:17.567 2009  to  Tue Apr 21 18:32:17.567 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15075

   7  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:33:03.488 2009  to  Tue Apr 21 18:33:03.488 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15079

   8  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:33:49.134 2009  to  Tue Apr 21 18:33:49.134 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15088

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Tue Apr 21 19:21:58.104 2009  to  Tue Apr 21 19:21:58.104 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr 21 19:30:36.259 2009  to  Tue Apr 21 19:30:36.259 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr 21 19:30:36.270 2009  to  Tue Apr 21 19:30:36.270 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  12  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr 21 19:30:36.365 2009  to  Tue Apr 21 19:30:36.365 2009   (  0.00) secs
                     drive cabinet has turned on.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.371 2009  to  Tue Apr 21 19:30:37.371 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.371 2009  to  Tue Apr 21 19:30:37.371 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.372 2009  to  Tue Apr 21 19:30:37.372 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.372 2009  to  Tue Apr 21 19:30:37.372 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.373 2009  to  Tue Apr 21 19:30:37.373 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.374 2009  to  Tue Apr 21 19:30:37.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.374 2009  to  Tue Apr 21 19:30:37.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.375 2009  to  Tue Apr 21 19:30:37.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr 21 19:56:38.974 2009  to  Tue Apr 21 19:56:38.974 2009   (  0.00) secs
                     MJDsec from DSP is 4.747085832981978e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.747085832981978e+09 seq=0

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr 21 19:56:38.976 2009  to  Tue Apr 21 19:56:38.976 2009   (  0.00) secs
                     MJDsec from DSP is 4.747085832983670e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747085832983670e+09 seq=0
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.05    0.08    0.04    0.23   100.0 %         41         41                      
                                                                       0.05    0.08    0.04    0.23
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.10    0.23    0.11    0.63   100.0 %        248        248                      
                                                                       0.10    0.23    0.11    0.63
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.05    0.06
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.23    0.55    0.05    1.16   100.0 %         62         62                      
                                                                       0.23    0.55    0.05    1.16
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.03    0.06    0.05    0.13   100.0 %          7          7                      
                                                                       0.03    0.06    0.05    0.13
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.25    0.24    0.06    0.68   100.0 %         26         26                      
                                                                       0.25    0.24    0.06    0.68
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.24    0.55    0.30    1.07   100.0 %         26         26                      
                                                                       0.24    0.55    0.30    1.07

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.05    2.93    2.05    6.06   100.0 %         38         38                      
                                                                       1.05    2.93    2.05    6.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    6.07    6.07    6.07   100.0 %          1          1                      
                                                                       0.00    6.07    6.07    6.07
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.86    4.65    0.00   89.21    99.3 %        868        862          6           
                                                                       4.87    4.68    2.05   89.21

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      15                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      15                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            28
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            24
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 31           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 31           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      31                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      38                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1
     servoLoop.upperLimit.exceeded. . . . . . . . . . . . . . . . .                            10

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:15:19.082 2009  to  Tue Apr 21 21:15:19.082 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

   2  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:15:19.134 2009  to  Tue Apr 21 21:15:19.134 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   3  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:18:26.739 2009  to  Tue Apr 21 21:18:26.739 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   4  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:18:26.791 2009  to  Tue Apr 21 21:18:26.791 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:37:49.428 2009  to  Tue Apr 21 21:37:49.428 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

   6  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:37:49.481 2009  to  Tue Apr 21 21:37:49.481 2009   (  0.00) secs
                     left PMC Mirror closing network connection

   7  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:37:55.040 2009  to  Tue Apr 21 21:38:04.101 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:38:04.101 2009  to  Tue Apr 21 21:38:04.153 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:38:10.119 2009  to  Tue Apr 21 21:38:10.119 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  10  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:06.981 2009  to  Tue Apr 21 21:39:26.830 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:26.830 2009  to  Tue Apr 21 21:39:26.883 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  12  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:48.118 2009  to  Tue Apr 21 21:39:48.118 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  13  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:46:17.304 2009  to  Tue Apr 21 21:46:17.304 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:46:17.252 2009  to  Tue Apr 21 21:46:17.252 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Tue Apr 21 22:11:09.590 2009  to  Tue Apr 21 22:11:09.590 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 22:11:09.537 2009  to  Tue Apr 21 22:11:09.537 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:26:44.408 2009  to  Wed Apr 22 00:26:44.408 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:26:44.460 2009  to  Wed Apr 22 00:26:44.460 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:34:28.036 2009  to  Wed Apr 22 00:34:28.036 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  20  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:34:28.088 2009  to  Wed Apr 22 00:34:28.088 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:40:09.583 2009  to  Wed Apr 22 00:40:09.583 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  22  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:40:09.635 2009  to  Wed Apr 22 00:40:09.635 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:43:01.657 2009  to  Wed Apr 22 00:43:01.657 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  24  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:43:01.709 2009  to  Wed Apr 22 00:43:01.709 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  25  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 01:07:03.340 2009  to  Wed Apr 22 01:07:03.340 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Wed Apr 22 01:07:03.391 2009  to  Wed Apr 22 01:07:03.391 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  27  FAILED    PMC        VxInterface.close                                             Wed Apr 22 01:20:25.670 2009  to  Wed Apr 22 01:20:25.670 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 01:20:25.619 2009  to  Wed Apr 22 01:20:25.619 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:06:30.651 2009  to  Wed Apr 22 02:06:30.651 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:06:30.599 2009  to  Wed Apr 22 02:06:30.599 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  31  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:10:13.216 2009  to  Wed Apr 22 02:10:13.216 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:10:13.165 2009  to  Wed Apr 22 02:10:13.165 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:21:46.059 2009  to  Wed Apr 22 02:21:46.059 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:21:46.111 2009  to  Wed Apr 22 02:21:46.111 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:24:47.331 2009  to  Wed Apr 22 02:24:47.331 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:24:47.383 2009  to  Wed Apr 22 02:24:47.383 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr 22 02:32:25.562 2009  to  Wed Apr 22 02:32:25.562 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  38  FAILED    PMC        thermal.badReceive                                            Wed Apr 22 02:32:25.666 2009  to  Wed Apr 22 02:32:25.666 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  39  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr 22 02:32:25.614 2009  to  Wed Apr 22 02:32:25.614 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  40  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:37:48.709 2009  to  Wed Apr 22 02:37:48.709 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  41  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:37:48.760 2009  to  Wed Apr 22 02:37:48.760 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  42  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:38:48.516 2009  to  Wed Apr 22 02:38:48.516 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:38:48.465 2009  to  Wed Apr 22 02:38:48.465 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  44  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:01:45.974 2009  to  Wed Apr 22 03:01:45.974 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:01:46.025 2009  to  Wed Apr 22 03:01:46.025 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:23:47.305 2009  to  Wed Apr 22 03:23:47.305 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:23:47.254 2009  to  Wed Apr 22 03:23:47.254 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  48  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:23:49.705 2009  to  Wed Apr 22 03:23:49.705 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:23:49.653 2009  to  Wed Apr 22 03:23:49.653 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:40:49.595 2009  to  Wed Apr 22 03:40:49.595 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:40:49.646 2009  to  Wed Apr 22 03:40:49.646 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:57:16.194 2009  to  Wed Apr 22 03:57:16.194 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:57:16.142 2009  to  Wed Apr 22 03:57:16.142 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:00:41.607 2009  to  Wed Apr 22 04:00:41.607 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  55  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:00:41.660 2009  to  Wed Apr 22 04:00:41.660 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  56  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:01:10.755 2009  to  Wed Apr 22 04:01:10.755 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:01:10.703 2009  to  Wed Apr 22 04:01:10.703 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:06:52.920 2009  to  Wed Apr 22 04:06:58.981 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:11:03.611 2009  to  Wed Apr 22 04:11:03.611 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:11:03.664 2009  to  Wed Apr 22 04:11:03.664 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:17:53.418 2009  to  Wed Apr 22 04:17:59.482 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:35.073 2009  to  Wed Apr 22 04:48:53.917 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:53.917 2009  to  Wed Apr 22 04:48:53.970 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:58.167 2009  to  Wed Apr 22 04:48:58.167 2009   (  0.00) secs
                    Failed event but no Started event
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.adjustPointing . . . . . . . . . . . . . . . . . . . .    6.02    6.29    0.00   15.40    93.3 %         15                     1           
                                                                       4.95    9.04    2.40   15.40
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.09    4.28    0.40   17.93    99.5 %        556        553          3           
                                                                       2.09    4.27    0.40   17.93
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.10   100.0 %         50         50                      
                                                                       0.01    0.05    0.05    0.10
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.01    5.28    2.39   27.44   100.0 %        289        289                      
                                                                       4.01    5.28    2.39   27.44
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.09    4.39    0.51   18.04    99.5 %        556        553          3           
                                                                       2.09    4.38    0.51   18.04
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.12    4.07    0.00   17.72    99.5 %        558        555          3           
                                                                       2.11    4.06    0.19   17.72
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.86    4.79    0.00   89.34    99.3 %        868        862          6           
                                                                       4.87    4.82    2.18   89.34
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    6.20    6.20    6.20   100.0 %          1          1                      
                                                                       0.00    6.20    6.20    6.20
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.05    0.10    0.07    0.30   100.0 %         51         51                      
                                                                       0.05    0.10    0.07    0.30
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   10.55   10.55   10.55   100.0 %          1          1                      
                                                                       0.00   10.55   10.55   10.55
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    3.90    5.10    2.28   27.34   100.0 %        289        289                      
                                                                       3.90    5.10    2.28   27.34
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setPointingOffsets . . . . . . . . . . .    6.62   11.84    2.29   23.33    93.3 %         15         14          1           
                                                                       6.03   11.02    2.29   19.32
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.04    0.12   100.0 %        558        558                      
                                                                       0.01    0.06    0.04    0.12

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1389           

PSF Events of Interest

   1  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:33.038 2009  to  Tue Apr 21 21:37:40.439 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip -1.0000000e+01, tilt 0.0000000e+00

   2  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:40.439 2009  to  Tue Apr 21 21:37:44.792 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt 0.0000000e+00

   3  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:54.873 2009  to  Tue Apr 21 21:37:54.873 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip -1.0000000e+01, tilt 0.0000000e+00

   4  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:37:54.981 2009  to  Tue Apr 21 21:38:04.042 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:38:04.042 2009  to  Tue Apr 21 21:38:04.224 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:38:10.186 2009  to  Tue Apr 21 21:38:10.186 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   7  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:38:10.297 2009  to  Tue Apr 21 21:38:10.297 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt 0.0000000e+00

   8  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:06.701 2009  to  Tue Apr 21 21:39:20.214 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

   9  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:06.922 2009  to  Tue Apr 21 21:39:26.773 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PSF        command.applyZernikes                                         Tue Apr 21 21:39:20.053 2009  to  Tue Apr 21 21:39:27.064 2009   (  7.01) secs
                     left PSF ApplyZernikes failed

  11  FAILED    PSF        command.setZernikes                                           Tue Apr 21 21:39:20.002 2009  to  Tue Apr 21 21:39:27.119 2009   (  7.12) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  12  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:20.214 2009  to  Tue Apr 21 21:39:27.009 2009   (  6.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:26.773 2009  to  Tue Apr 21 21:39:26.954 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  14  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:48.185 2009  to  Tue Apr 21 21:39:48.185 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  15  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:48.241 2009  to  Tue Apr 21 21:39:48.241 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  16  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.302 2009  to  Tue Apr 21 21:39:48.302 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.555 2009  to  Tue Apr 21 21:39:48.555 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  18  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.809 2009  to  Tue Apr 21 21:39:48.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.9561391e-03 -1.2673587e-03 1.0946357e-01 -2.5310516e-03 -2.7275085e-03 1.5489474e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.064 2009  to  Tue Apr 21 21:39:49.064 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  20  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.319 2009  to  Tue Apr 21 21:39:49.319 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  21  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.574 2009  to  Tue Apr 21 21:39:49.574 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  22  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.829 2009  to  Tue Apr 21 21:39:49.829 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  23  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.087 2009  to  Tue Apr 21 21:39:50.087 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  24  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.342 2009  to  Tue Apr 21 21:39:50.342 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.597 2009  to  Tue Apr 21 21:39:50.597 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2961240e-03 -1.2595654e-03 1.0928002e-01 1.9798279e-02 2.5062561e-03 2.5886908e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.852 2009  to  Tue Apr 21 21:39:50.852 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2961240e-03 -1.2595654e-03 1.0928002e-01 1.9798279e-02 2.5062561e-03 2.5886908e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.107 2009  to  Tue Apr 21 21:39:51.107 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.362 2009  to  Tue Apr 21 21:39:51.362 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  29  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.617 2009  to  Tue Apr 21 21:39:51.617 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.872 2009  to  Tue Apr 21 21:39:51.872 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.127 2009  to  Tue Apr 21 21:39:52.127 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.382 2009  to  Tue Apr 21 21:39:52.382 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.649 2009  to  Tue Apr 21 21:39:52.649 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2779446e-03 -1.1934787e-03 1.0924423e-01 4.3720245e-02 -4.0969849e-02 2.7867705e-03

  34  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.903 2009  to  Tue Apr 21 21:39:52.903 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.158 2009  to  Tue Apr 21 21:39:53.158 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.413 2009  to  Tue Apr 21 21:39:53.413 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.668 2009  to  Tue Apr 21 21:39:53.668 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  38  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.924 2009  to  Tue Apr 21 21:39:53.924 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3143630e-03 -1.8562526e-03 1.0983557e-01 2.9283524e-02 -3.6617279e-02 -5.5829138e-03

  39  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:54.180 2009  to  Tue Apr 21 21:39:54.180 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3143630e-03 -1.8562526e-03 1.0983557e-01 2.9283524e-02 -3.6617279e-02 -5.5829138e-03

  40  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:54.436 2009  to  Tue Apr 21 21:39:54.436 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  41  FAILED    PSF        command.setZernikes                                           Wed Apr 22 04:06:52.454 2009  to  Wed Apr 22 04:06:59.225 2009   (  6.77) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  42  FAILED    PSF        command.applyZernikes                                         Wed Apr 22 04:06:52.508 2009  to  Wed Apr 22 04:06:59.169 2009   (  6.66) secs
                     left PSF ApplyZernikes failed

  43  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Apr 22 04:06:52.671 2009  to  Wed Apr 22 04:06:59.111 2009   (  6.44) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:06:52.864 2009  to  Wed Apr 22 04:06:59.055 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  45  FAILED    PSF        command.setZernikes                                           Wed Apr 22 04:17:52.892 2009  to  Wed Apr 22 04:17:59.731 2009   (  6.84) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  46  FAILED    PSF        command.applyZernikes                                         Wed Apr 22 04:17:52.944 2009  to  Wed Apr 22 04:17:59.673 2009   (  6.73) secs
                     left PSF ApplyZernikes failed

  47  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Apr 22 04:17:53.109 2009  to  Wed Apr 22 04:17:59.615 2009   (  6.51) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:17:53.301 2009  to  Wed Apr 22 04:17:59.557 2009   (  6.26) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Wed Apr 22 04:48:34.964 2009  to  Wed Apr 22 04:48:58.298 2009   ( 23.33) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

  50  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:48:34.911 2009  to  Wed Apr 22 04:48:40.506 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 0.0000000e+00, tilt 0.0000000e+00

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:35.016 2009  to  Wed Apr 22 04:48:53.860 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  52  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:48:40.506 2009  to  Wed Apr 22 04:48:45.310 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip -2.0000000e+01, tilt 0.0000000e+00

  53  FAILED    PSF        command.adjustPointing                                        Wed Apr 22 04:48:45.310 2009  to  Wed Apr 22 04:48:58.355 2009   ( 13.04) secs
                     left PSF AdjustPointing failed for tip 0.0000000e+00, tilt 2.0000000e+01

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:53.860 2009  to  Wed Apr 22 04:48:54.041 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  55  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:58.242 2009  to  Wed Apr 22 04:48:58.242 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  56  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:49:15.790 2009  to  Wed Apr 22 04:49:15.790 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 0.0000000e+00, tilt 0.0000000e+00

  57  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:49:31.621 2009  to  Wed Apr 22 04:49:31.621 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip -3.0000000e+01, tilt 0.0000000e+00

  58  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:50:36.703 2009  to  Wed Apr 22 04:50:45.386 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt -1.0000000e+01

  59  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:51:08.552 2009  to  Wed Apr 22 04:51:08.552 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt -1.0000000e+01
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:25:42.350 2009  to  Tue Apr 21 18:25:42.350 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15100

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:26:06.178 2009  to  Tue Apr 21 18:26:06.178 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15155

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:27:10.731 2009  to  Tue Apr 21 18:27:10.731 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15223

   4  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:30:45.791 2009  to  Tue Apr 21 18:30:45.791 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15105

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:31:19.445 2009  to  Tue Apr 21 18:31:19.445 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15187

   6  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:32:17.567 2009  to  Tue Apr 21 18:32:17.567 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15075

   7  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:33:03.488 2009  to  Tue Apr 21 18:33:03.488 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15079

   8  FAILED    MCS.MCSPU  MCSPU.AZDrive.energizeAckFail                                 Tue Apr 21 18:33:49.134 2009  to  Tue Apr 21 18:33:49.134 2009   (  0.00) secs
                     Energize command was not acknowledged by TPLC after 15088

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Tue Apr 21 19:21:58.104 2009  to  Tue Apr 21 19:21:58.104 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr 21 19:30:36.259 2009  to  Tue Apr 21 19:30:36.259 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr 21 19:30:36.270 2009  to  Tue Apr 21 19:30:36.270 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  12  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr 21 19:30:36.365 2009  to  Tue Apr 21 19:30:36.365 2009   (  0.00) secs
                     drive cabinet has turned on.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.371 2009  to  Tue Apr 21 19:30:37.371 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.371 2009  to  Tue Apr 21 19:30:37.371 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.372 2009  to  Tue Apr 21 19:30:37.372 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.372 2009  to  Tue Apr 21 19:30:37.372 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.373 2009  to  Tue Apr 21 19:30:37.373 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.374 2009  to  Tue Apr 21 19:30:37.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.374 2009  to  Tue Apr 21 19:30:37.374 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr 21 19:30:37.375 2009  to  Tue Apr 21 19:30:37.375 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr 21 19:56:38.974 2009  to  Tue Apr 21 19:56:38.974 2009   (  0.00) secs
                     MJDsec from DSP is 4.747085832981978e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.747085832981978e+09 seq=0

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr 21 19:56:38.976 2009  to  Tue Apr 21 19:56:38.976 2009   (  0.00) secs
                     MJDsec from DSP is 4.747085832983670e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.747085832983670e+09 seq=0

  23  FAILED    IIF        command.preset.(TRACK)                                        Tue Apr 21 20:09:31.008 2009  to  Tue Apr 21 20:14:34.366 2009   (303.36) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494313164351852e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

  24  SEQERROR  IIF        command.preset.elevationWait                                  Tue Apr 21 20:09:33.585 2009  to  Tue Apr 21 21:14:58.753 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

  25  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:15:19.082 2009  to  Tue Apr 21 21:15:19.082 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  26  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:15:19.134 2009  to  Tue Apr 21 21:15:19.134 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:18:26.739 2009  to  Tue Apr 21 21:18:26.739 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  28  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:18:26.791 2009  to  Tue Apr 21 21:18:26.791 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  29  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:33.038 2009  to  Tue Apr 21 21:37:40.439 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip -1.0000000e+01, tilt 0.0000000e+00

  30  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:40.439 2009  to  Tue Apr 21 21:37:44.792 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt 0.0000000e+00

  31  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:37:49.428 2009  to  Tue Apr 21 21:37:49.428 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  32  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:37:49.481 2009  to  Tue Apr 21 21:37:49.481 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  33  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:37:54.873 2009  to  Tue Apr 21 21:37:54.873 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip -1.0000000e+01, tilt 0.0000000e+00

  34  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:37:54.981 2009  to  Tue Apr 21 21:38:04.042 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  35  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:37:55.040 2009  to  Tue Apr 21 21:38:04.101 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:38:04.042 2009  to  Tue Apr 21 21:38:04.224 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:38:04.101 2009  to  Tue Apr 21 21:38:04.153 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  38  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:38:10.119 2009  to  Tue Apr 21 21:38:10.119 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  39  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:38:10.186 2009  to  Tue Apr 21 21:38:10.186 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  40  SEQERROR  PSF        command.adjustPointing                                        Tue Apr 21 21:38:10.297 2009  to  Tue Apr 21 21:38:10.297 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt 0.0000000e+00

  41  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:06.701 2009  to  Tue Apr 21 21:39:20.214 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  42  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:06.922 2009  to  Tue Apr 21 21:39:26.773 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  43  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:06.981 2009  to  Tue Apr 21 21:39:26.830 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  44  FAILED    IIF        command.sendWavefront                                         Tue Apr 21 21:39:19.934 2009  to  Tue Apr 21 21:39:27.233 2009   (  7.30) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

  45  FAILED    PSF        command.applyZernikes                                         Tue Apr 21 21:39:20.053 2009  to  Tue Apr 21 21:39:27.064 2009   (  7.01) secs
                     left PSF ApplyZernikes failed

  46  FAILED    PSF        command.setZernikes                                           Tue Apr 21 21:39:20.002 2009  to  Tue Apr 21 21:39:27.119 2009   (  7.12) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  47  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:20.214 2009  to  Tue Apr 21 21:39:27.009 2009   (  6.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:26.773 2009  to  Tue Apr 21 21:39:26.954 2009   (  0.18) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:26.830 2009  to  Tue Apr 21 21:39:26.883 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Apr 21 21:39:48.118 2009  to  Tue Apr 21 21:39:48.118 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Apr 21 21:39:48.185 2009  to  Tue Apr 21 21:39:48.185 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  52  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Apr 21 21:39:48.241 2009  to  Tue Apr 21 21:39:48.241 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  53  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.302 2009  to  Tue Apr 21 21:39:48.302 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  54  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.555 2009  to  Tue Apr 21 21:39:48.555 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  55  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:48.809 2009  to  Tue Apr 21 21:39:48.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 3.9561391e-03 -1.2673587e-03 1.0946357e-01 -2.5310516e-03 -2.7275085e-03 1.5489474e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.064 2009  to  Tue Apr 21 21:39:49.064 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  57  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.319 2009  to  Tue Apr 21 21:39:49.319 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  58  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.574 2009  to  Tue Apr 21 21:39:49.574 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  59  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:49.829 2009  to  Tue Apr 21 21:39:49.829 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  60  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.087 2009  to  Tue Apr 21 21:39:50.087 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  61  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.342 2009  to  Tue Apr 21 21:39:50.342 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  62  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.597 2009  to  Tue Apr 21 21:39:50.597 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2961240e-03 -1.2595654e-03 1.0928002e-01 1.9798279e-02 2.5062561e-03 2.5886908e-02

  63  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:50.852 2009  to  Tue Apr 21 21:39:50.852 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2961240e-03 -1.2595654e-03 1.0928002e-01 1.9798279e-02 2.5062561e-03 2.5886908e-02

  64  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.107 2009  to  Tue Apr 21 21:39:51.107 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  65  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.362 2009  to  Tue Apr 21 21:39:51.362 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  66  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.617 2009  to  Tue Apr 21 21:39:51.617 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  67  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:51.872 2009  to  Tue Apr 21 21:39:51.872 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1174293e-03 -9.7250938e-04 1.0964495e-01 4.0245056e-03 1.8970490e-02 5.2145869e-03

  68  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.127 2009  to  Tue Apr 21 21:39:52.127 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  69  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.382 2009  to  Tue Apr 21 21:39:52.382 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  70  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.649 2009  to  Tue Apr 21 21:39:52.649 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.2779446e-03 -1.1934787e-03 1.0924423e-01 4.3720245e-02 -4.0969849e-02 2.7867705e-03

  71  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:52.903 2009  to  Tue Apr 21 21:39:52.903 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.158 2009  to  Tue Apr 21 21:39:53.158 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  73  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.413 2009  to  Tue Apr 21 21:39:53.413 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4757128e-03 -1.5614033e-03 1.1001694e-01 3.5839081e-02 -1.4923096e-02 -1.5857801e-02

  74  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.668 2009  to  Tue Apr 21 21:39:53.668 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  75  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:53.924 2009  to  Tue Apr 21 21:39:53.924 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3143630e-03 -1.8562526e-03 1.0983557e-01 2.9283524e-02 -3.6617279e-02 -5.5829138e-03

  76  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:54.180 2009  to  Tue Apr 21 21:39:54.180 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.3143630e-03 -1.8562526e-03 1.0983557e-01 2.9283524e-02 -3.6617279e-02 -5.5829138e-03

  77  FAILED    PSF        primaryMirror.positionError                                   Tue Apr 21 21:39:54.436 2009  to  Tue Apr 21 21:39:54.436 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.1352510e-03 -1.5618056e-03 1.0964957e-01 1.3376236e-02 -1.9672394e-02 4.9532801e-03

  78  FAILED    PMC        VxInterface.close                                             Tue Apr 21 21:46:17.304 2009  to  Tue Apr 21 21:46:17.304 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  79  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 21:46:17.252 2009  to  Tue Apr 21 21:46:17.252 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  80  FAILED    PMC        VxInterface.close                                             Tue Apr 21 22:11:09.590 2009  to  Tue Apr 21 22:11:09.590 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  81  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 22:11:09.537 2009  to  Tue Apr 21 22:11:09.537 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  82  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:26:44.408 2009  to  Wed Apr 22 00:26:44.408 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  83  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:26:44.460 2009  to  Wed Apr 22 00:26:44.460 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  84  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:34:28.036 2009  to  Wed Apr 22 00:34:28.036 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  85  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:34:28.088 2009  to  Wed Apr 22 00:34:28.088 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  86  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:40:09.583 2009  to  Wed Apr 22 00:40:09.583 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  87  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:40:09.635 2009  to  Wed Apr 22 00:40:09.635 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  88  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 00:43:01.657 2009  to  Wed Apr 22 00:43:01.657 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  89  FAILED    PMC        VxInterface.close                                             Wed Apr 22 00:43:01.709 2009  to  Wed Apr 22 00:43:01.709 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 01:07:03.340 2009  to  Wed Apr 22 01:07:03.340 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  91  FAILED    PMC        VxInterface.close                                             Wed Apr 22 01:07:03.391 2009  to  Wed Apr 22 01:07:03.391 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  92  FAILED    PMC        VxInterface.close                                             Wed Apr 22 01:20:25.670 2009  to  Wed Apr 22 01:20:25.670 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  93  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 01:20:25.619 2009  to  Wed Apr 22 01:20:25.619 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  94  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:06:30.651 2009  to  Wed Apr 22 02:06:30.651 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  95  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:06:30.599 2009  to  Wed Apr 22 02:06:30.599 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  96  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:10:13.216 2009  to  Wed Apr 22 02:10:13.216 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  97  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:10:13.165 2009  to  Wed Apr 22 02:10:13.165 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  98  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:21:46.059 2009  to  Wed Apr 22 02:21:46.059 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  99  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:21:46.111 2009  to  Wed Apr 22 02:21:46.111 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 100  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:24:47.331 2009  to  Wed Apr 22 02:24:47.331 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 101  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:24:47.383 2009  to  Wed Apr 22 02:24:47.383 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr 22 02:32:25.562 2009  to  Wed Apr 22 02:32:25.562 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 103  FAILED    PMC        thermal.badReceive                                            Wed Apr 22 02:32:25.666 2009  to  Wed Apr 22 02:32:25.666 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 104  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr 22 02:32:25.614 2009  to  Wed Apr 22 02:32:25.614 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 105  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:37:48.709 2009  to  Wed Apr 22 02:37:48.709 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

 106  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:37:48.760 2009  to  Wed Apr 22 02:37:48.760 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 107  FAILED    PMC        VxInterface.close                                             Wed Apr 22 02:38:48.516 2009  to  Wed Apr 22 02:38:48.516 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 108  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 02:38:48.465 2009  to  Wed Apr 22 02:38:48.465 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 109  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:01:45.974 2009  to  Wed Apr 22 03:01:45.974 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 110  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:01:46.025 2009  to  Wed Apr 22 03:01:46.025 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 111  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:23:47.305 2009  to  Wed Apr 22 03:23:47.305 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 112  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:23:47.254 2009  to  Wed Apr 22 03:23:47.254 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 113  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:23:49.705 2009  to  Wed Apr 22 03:23:49.705 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 114  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:23:49.653 2009  to  Wed Apr 22 03:23:49.653 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 115  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:40:49.595 2009  to  Wed Apr 22 03:40:49.595 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 116  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:40:49.646 2009  to  Wed Apr 22 03:40:49.646 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 117  FAILED    PMC        VxInterface.close                                             Wed Apr 22 03:57:16.194 2009  to  Wed Apr 22 03:57:16.194 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 118  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 03:57:16.142 2009  to  Wed Apr 22 03:57:16.142 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 119  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:00:41.607 2009  to  Wed Apr 22 04:00:41.607 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

 120  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:00:41.660 2009  to  Wed Apr 22 04:00:41.660 2009   (  0.00) secs
                     left PMC Mirror closing network connection

 121  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:01:10.755 2009  to  Wed Apr 22 04:01:10.755 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 122  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:01:10.703 2009  to  Wed Apr 22 04:01:10.703 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 123  FAILED    IIF        command.sendWavefront                                         Wed Apr 22 04:06:52.369 2009  to  Wed Apr 22 04:06:59.327 2009   (  6.96) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

 124  FAILED    PSF        command.setZernikes                                           Wed Apr 22 04:06:52.454 2009  to  Wed Apr 22 04:06:59.225 2009   (  6.77) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 125  FAILED    PSF        command.applyZernikes                                         Wed Apr 22 04:06:52.508 2009  to  Wed Apr 22 04:06:59.169 2009   (  6.66) secs
                     left PSF ApplyZernikes failed

 126  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Apr 22 04:06:52.671 2009  to  Wed Apr 22 04:06:59.111 2009   (  6.44) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 127  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:06:52.864 2009  to  Wed Apr 22 04:06:59.055 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 128  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:06:52.920 2009  to  Wed Apr 22 04:06:58.981 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 129  FAILED    PMC        VxInterface.lengthError                                       Wed Apr 22 04:11:03.611 2009  to  Wed Apr 22 04:11:03.611 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 130  FAILED    PMC        VxInterface.close                                             Wed Apr 22 04:11:03.664 2009  to  Wed Apr 22 04:11:03.664 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 131  FAILED    IIF        command.sendWavefront                                         Wed Apr 22 04:17:52.808 2009  to  Wed Apr 22 04:17:59.834 2009   (  7.03) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

 132  FAILED    PSF        command.setZernikes                                           Wed Apr 22 04:17:52.892 2009  to  Wed Apr 22 04:17:59.731 2009   (  6.84) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 133  FAILED    PSF        command.applyZernikes                                         Wed Apr 22 04:17:52.944 2009  to  Wed Apr 22 04:17:59.673 2009   (  6.73) secs
                     left PSF ApplyZernikes failed

 134  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Apr 22 04:17:53.109 2009  to  Wed Apr 22 04:17:59.615 2009   (  6.51) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 135  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:17:53.301 2009  to  Wed Apr 22 04:17:59.557 2009   (  6.26) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 136  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:17:53.418 2009  to  Wed Apr 22 04:17:59.482 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 137  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 04:34:37.725 2009  to  Wed Apr 22 04:39:40.030 2009   (302.31) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494348239583334e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

 138  SEQERROR  IIF        command.preset.elevationWait                                  Wed Apr 22 04:34:39.179 2009  to  Wed Apr 22 04:42:35.664 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

 139  FAILED    IIF        command.preset.(TRACK)                                        Wed Apr 22 04:48:15.561 2009  to  Wed Apr 22 04:49:21.405 2009   ( 65.84) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494349186342592e+04, time 3.470000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset command failed for both LBC mode TRACK from IIF

 140  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Wed Apr 22 04:48:34.964 2009  to  Wed Apr 22 04:48:58.298 2009   ( 23.33) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

 141  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:48:34.911 2009  to  Wed Apr 22 04:48:40.506 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 0.0000000e+00, tilt 0.0000000e+00

 142  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:35.016 2009  to  Wed Apr 22 04:48:53.860 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 143  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:35.073 2009  to  Wed Apr 22 04:48:53.917 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 144  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:48:40.506 2009  to  Wed Apr 22 04:48:45.310 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip -2.0000000e+01, tilt 0.0000000e+00

 145  FAILED    PSF        command.adjustPointing                                        Wed Apr 22 04:48:45.310 2009  to  Wed Apr 22 04:48:58.355 2009   ( 13.04) secs
                     left PSF AdjustPointing failed for tip 0.0000000e+00, tilt 2.0000000e+01

 146  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:53.860 2009  to  Wed Apr 22 04:48:54.041 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 147  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:53.917 2009  to  Wed Apr 22 04:48:53.970 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 148  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Apr 22 04:48:58.167 2009  to  Wed Apr 22 04:48:58.167 2009   (  0.00) secs
                    Failed event but no Started event
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 149  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Apr 22 04:48:58.242 2009  to  Wed Apr 22 04:48:58.242 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 150  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:49:15.790 2009  to  Wed Apr 22 04:49:15.790 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 0.0000000e+00, tilt 0.0000000e+00

 151  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:49:31.621 2009  to  Wed Apr 22 04:49:31.621 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip -3.0000000e+01, tilt 0.0000000e+00

 152  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:50:36.703 2009  to  Wed Apr 22 04:50:45.386 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 2.0000000e+01, tilt -1.0000000e+01

 153  SEQERROR  PSF        command.adjustPointing                                        Wed Apr 22 04:51:08.552 2009  to  Wed Apr 22 04:51:08.552 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 2.0000000e+01, tilt -1.0000000e+01

**********************************************************
    Reporting period ending:   Wed Apr 22 06:11:51.932 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback