    TCS Software Performance Report
 
    Observing Night:   Apr 20 2009 to Apr 21 2009
 
    Reporting period beginning:   Mon Apr 20 18:23:00.187 2009
    Reporting period ending:      Tue Apr 21 06:12:55.642 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = pcs.guider.command.enableGuiding.started,  priority = 0, 2
      event = pcs.guider.command.enableGuiding.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.07   100.0 %         78         78                      
                                                                       0.00    0.05    0.05    0.07
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.35    0.57    0.25    1.71   100.0 %        342        342                      
                                                                       0.35    0.57    0.25    1.71
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.02    0.19    0.16    0.31   100.0 %        390        390                      
                                                                       0.02    0.19    0.16    0.31
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.24    6.42    2.52   41.72    99.6 %        263        262          1           
                                                                       5.24    6.43    2.52   41.72
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .   33.76    9.04    0.00  301.11    98.7 %         77         76          1               timeout =     1
                                                                       1.50    5.34    0.22    8.73
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.61    4.27    0.00    7.67    98.7 %         77         76                      
                                                                       1.47    4.39    2.06    7.67
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   11.09    6.27    1.05   47.14    96.7 %         30         29                      
                                                                      11.09    6.27    1.05   47.14
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   43.71   18.96    2.06  188.41   100.0 %         29         29                      
                                                                      43.71   18.96    2.06  188.41
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   74.41   42.36    7.71  301.82    96.7 %         30         27          1          2    timeout =     1
                                                                      55.36   32.75    7.71  243.47
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    3.35    5.26    0.64   33.17   100.0 %        400        400                      
                                                                       3.35    5.26    0.64   33.17
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.32    3.71    2.53    6.59   100.0 %         25         25                      
                                                                       1.32    3.71    2.53    6.59

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            10

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Mon Apr 20 19:14:30.326 2009  to  Mon Apr 20 19:14:32.957 2009   (  2.63) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494209341435185e+04, time 3.458000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 3.530000000000000e-01

   2  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:20.439 2009  to  Tue Apr 21 03:21:23.501 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

   3  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:20.658 2009  to  Tue Apr 21 03:21:23.683 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

   4  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:23.501 2009  to  Tue Apr 21 03:21:27.580 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

   5  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:27.763 2009  to  Tue Apr 21 03:21:31.831 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

   6  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:39.953 2009  to  Tue Apr 21 03:21:39.953 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

   7  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:39.900 2009  to  Tue Apr 21 03:21:39.900 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

   8  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:40.206 2009  to  Tue Apr 21 03:21:40.206 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

   9  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:40.152 2009  to  Tue Apr 21 03:21:40.152 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

  10  FAILED    IIF        command.preset.(TRACK)                                        Tue Apr 21 03:24:11.475 2009  to  Tue Apr 21 03:29:13.299 2009   (301.82) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494243348379630e+04, time 5.250000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

  11  SEQERROR  IIF        command.preset.elevationWait                                  Tue Apr 21 03:24:12.472 2009  to  Tue Apr 21 03:31:22.124 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

  12  FAILED    IIF        command.offset                                                Tue Apr 21 03:38:39.612 2009  to  Tue Apr 21 03:43:40.720 2009   (301.11) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  13  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:38:39.996 2009  to  Tue Apr 21 04:14:44.510 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3517                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7034                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      31                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         35                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            56
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             7
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      68                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     206                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     732                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     246                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon Apr 20 19:03:36.761 2009  to  Mon Apr 20 19:03:36.761 2009   (  0.00) secs
                     MJDsec from DSP is 4.746996250769176e+09 but t0 of the AZ target polynomial is 4.746984677429000e+09. Difference= 1.157334017562866e+04 seq=4770344

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon Apr 20 19:03:36.763 2009  to  Mon Apr 20 19:03:36.763 2009   (  0.00) secs
                     MJDsec from DSP is 4.746996250770908e+09 but t0 of the EL target polynomial is 4.746966806296000e+09. Difference= 2.944447490882874e+04 seq=4445031

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr 21 03:29:29.770 2009  to  Tue Apr 21 03:29:29.770 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.enableGuiding . . . . . . . . . . . . . . . . .    0.02    0.06    0.05    0.09   100.0 %          4          4                      
                                                                       0.02    0.06    0.05    0.09
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %        390        390                        guidingNotEnabled =     2
                                                                       0.01    0.05    0.04    0.11
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.08    0.21    0.11    0.59   100.0 %        342        342                      
                                                                       0.08    0.21    0.11    0.59
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.30    0.47    0.05    1.14   100.0 %         77         77                      
                                                                       0.30    0.47    0.05    1.14
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.07    0.08    0.05    0.34   100.0 %         31         31                      
                                                                       0.07    0.08    0.05    0.34
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.21    0.59    0.31    0.85   100.0 %         31         31                      
                                                                       0.21    0.59    0.31    0.85

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 01:13:43.851 2009  to  Tue Apr 21 01:13:43.939 2009   (  0.09) secs
                    

   2  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 03:00:32.742 2009  to  Tue Apr 21 03:00:32.795 2009   (  0.05) secs
                    

   3  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 03:06:17.643 2009  to  Tue Apr 21 03:06:17.695 2009   (  0.05) secs
                    
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.05    2.91    2.05    6.07   100.0 %         80         80                      
                                                                       1.05    2.91    2.05    6.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.33    2.89    2.06    5.06   100.0 %          6          6                      
                                                                       1.33    2.89    2.06    5.06
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.92    1.44    0.00    2.06   100.0 %          5          5                      
                                                                       0.52    1.79    1.01    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    5.85    5.41    2.05   72.19    99.3 %        738        733          5           
                                                                       5.82    5.39    2.05   72.19

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       6                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            19
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  6           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  6           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  6           
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             6
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      80                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 21           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 21           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      21                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 19:14:30.564 2009  to  Mon Apr 20 19:14:32.619 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Apr 20 19:14:32.369 2009  to  Mon Apr 20 19:14:35.418 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 19:14:33.228 2009  to  Mon Apr 20 19:14:36.285 2009   (  3.06) secs
                    Started event but no Complete event
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Apr 20 19:14:37.473 2009  to  Mon Apr 20 19:14:37.473 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror ChaseStop Command Complete

   5  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 19:37:44.543 2009  to  Mon Apr 20 19:37:44.543 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   6  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 19:37:44.491 2009  to  Mon Apr 20 19:37:44.491 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   7  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 19:37:44.595 2009  to  Mon Apr 20 19:37:44.595 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   8  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 20:19:34.440 2009  to  Mon Apr 20 20:19:34.440 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Mon Apr 20 20:19:34.491 2009  to  Mon Apr 20 20:19:34.491 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 20:29:13.172 2009  to  Mon Apr 20 20:29:13.172 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  11  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 20:29:13.119 2009  to  Mon Apr 20 20:29:13.119 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  12  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 20:29:13.224 2009  to  Mon Apr 20 20:29:13.224 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  13  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:11:21.468 2009  to  Mon Apr 20 21:11:21.468 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:11:21.519 2009  to  Mon Apr 20 21:11:21.519 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:14:03.743 2009  to  Mon Apr 20 21:14:03.743 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:14:03.795 2009  to  Mon Apr 20 21:14:03.795 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:28:49.608 2009  to  Mon Apr 20 21:28:49.608 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  18  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:28:49.660 2009  to  Mon Apr 20 21:28:49.660 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  19  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:59:09.381 2009  to  Mon Apr 20 21:59:09.381 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:59:09.329 2009  to  Mon Apr 20 21:59:09.329 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:09:17.288 2009  to  Mon Apr 20 22:09:17.288 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:09:17.236 2009  to  Mon Apr 20 22:09:17.236 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  23  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:15:40.730 2009  to  Mon Apr 20 22:15:40.730 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:15:40.677 2009  to  Mon Apr 20 22:15:40.677 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:32:19.225 2009  to  Mon Apr 20 22:32:19.225 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:32:19.277 2009  to  Mon Apr 20 22:32:19.277 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:45:31.803 2009  to  Mon Apr 20 22:45:31.803 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  28  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:45:31.855 2009  to  Mon Apr 20 22:45:31.855 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  29  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:50:28.158 2009  to  Mon Apr 20 22:50:28.158 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  30  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:50:28.210 2009  to  Mon Apr 20 22:50:28.210 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  31  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:55:26.565 2009  to  Mon Apr 20 22:55:26.565 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:55:26.512 2009  to  Mon Apr 20 22:55:26.512 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:22:22.766 2009  to  Mon Apr 20 23:22:22.766 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:22:22.819 2009  to  Mon Apr 20 23:22:22.819 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:26:15.531 2009  to  Mon Apr 20 23:26:15.531 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  36  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:26:15.583 2009  to  Mon Apr 20 23:26:15.583 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  37  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:40:01.157 2009  to  Mon Apr 20 23:40:01.157 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:40:01.105 2009  to  Mon Apr 20 23:40:01.105 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:45:48.851 2009  to  Mon Apr 20 23:45:50.907 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  40  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:45:53.484 2009  to  Mon Apr 20 23:46:18.583 2009   ( 25.10) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  41  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:46:20.586 2009  to  Mon Apr 20 23:46:26.648 2009   (  6.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 23:54:44.598 2009  to  Mon Apr 20 23:54:44.598 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  43  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 23:54:44.705 2009  to  Mon Apr 20 23:54:44.705 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  44  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 23:54:44.652 2009  to  Mon Apr 20 23:54:44.652 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  45  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:03:16.193 2009  to  Tue Apr 21 00:03:16.193 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  46  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:03:16.245 2009  to  Tue Apr 21 00:03:16.245 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:20:11.290 2009  to  Tue Apr 21 00:20:11.290 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  48  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:20:11.238 2009  to  Tue Apr 21 00:20:11.238 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:40:03.758 2009  to  Tue Apr 21 00:40:03.758 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  50  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:40:03.809 2009  to  Tue Apr 21 00:40:03.809 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:40:40.652 2009  to  Tue Apr 21 00:40:40.652 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:40:40.705 2009  to  Tue Apr 21 00:40:40.705 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 00:50:50.930 2009  to  Tue Apr 21 00:50:50.930 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  54  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 00:50:50.873 2009  to  Tue Apr 21 00:50:50.873 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  55  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 00:50:50.983 2009  to  Tue Apr 21 00:50:50.983 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  56  FAILED    PMC        VxInterface.close                                             Tue Apr 21 01:13:08.309 2009  to  Tue Apr 21 01:13:08.309 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 01:13:08.257 2009  to  Tue Apr 21 01:13:08.257 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 02:47:19.096 2009  to  Tue Apr 21 02:47:19.096 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  59  FAILED    PMC        VxInterface.close                                             Tue Apr 21 02:47:19.148 2009  to  Tue Apr 21 02:47:19.148 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  60  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 02:47:32.090 2009  to  Tue Apr 21 02:47:32.090 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  61  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 02:47:32.036 2009  to  Tue Apr 21 02:47:32.036 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  62  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 02:47:32.143 2009  to  Tue Apr 21 02:47:32.143 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  63  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 02:52:17.451 2009  to  Tue Apr 21 02:52:17.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Tue Apr 21 02:52:17.503 2009  to  Tue Apr 21 02:52:17.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  65  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 06:04:06.786 2009  to  Tue Apr 21 06:04:06.786 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  66  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 06:04:06.896 2009  to  Tue Apr 21 06:04:06.896 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  67  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 06:04:06.842 2009  to  Tue Apr 21 06:04:06.842 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.adjustPointing . . . . . . . . . . . . . . . . . . . .    7.00    6.72    0.00   17.43   100.0 %          9          9                      
                                                                       6.98    7.56    0.25   17.43
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.36    4.99    0.41   32.92   100.0 %        400        400                      
                                                                       3.36    4.99    0.41   32.92
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.12   100.0 %         60         60                      
                                                                       0.01    0.06    0.05    0.12
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.07    6.04    2.39   41.47    99.7 %        288        287          1           
                                                                       5.08    6.05    2.39   41.47
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.35    5.11    0.51   33.03   100.0 %        400        400                      
                                                                       3.35    5.11    0.51   33.03
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.36    5.04    0.19   41.55   100.0 %        410        410                      
                                                                       4.36    5.04    0.19   41.55
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    5.86    5.55    2.18   72.31    99.3 %        738        733          5           
                                                                       5.83    5.54    2.18   72.31
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.97    1.53    0.00    2.18   100.0 %          5          5                      
                                                                       0.52    1.92    1.14    2.18
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.33    3.03    2.19    5.19   100.0 %          6          6                      
                                                                       1.33    3.03    2.19    5.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.06    0.10    0.06    0.51   100.0 %        122        122                      
                                                                       0.06    0.10    0.06    0.51
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   29.54   24.18    5.55   74.67    60.0 %          5          3          2           
                                                                      34.59   36.27    7.54   74.67
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.03    5.90    2.28   41.36    99.3 %        289        287          2           
                                                                       5.04    5.91    2.28   41.36
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.02    0.06    0.06    0.11   100.0 %         10         10                      
                                                                       0.02    0.06    0.06    0.11
     primaryMirror.command.setPointingOffsets . . . . . . . . . . .    7.17   10.72    2.36   25.34    90.0 %         10          9          1           
                                                                       5.31    9.10    2.36   17.32
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.10   100.0 %        410        410                      
                                                                       0.00    0.05    0.05    0.10

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1736           

PSF Events of Interest

   1  FAILED    PSF        command.setInstrumentOffsets                                  Mon Apr 20 19:14:30.397 2009  to  Mon Apr 20 19:14:32.794 2009   (  2.40) secs
                     left PSF SetInstrumentOffsets failed

   2  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Apr 20 19:14:30.448 2009  to  Mon Apr 20 19:14:32.739 2009   (  2.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 19:14:30.501 2009  to  Mon Apr 20 19:14:32.684 2009   (  2.18) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.revert                                  Mon Apr 20 19:14:30.853 2009  to  Mon Apr 20 19:14:36.405 2009   (  5.55) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Apr 20 19:14:32.310 2009  to  Mon Apr 20 19:14:35.357 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 19:14:33.167 2009  to  Mon Apr 20 19:14:36.349 2009   (  3.18) secs
                    Started event but no Complete event
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Apr 20 19:14:37.537 2009  to  Mon Apr 20 19:14:37.537 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror chaseStop complete

   8  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:09.022 2009  to  Mon Apr 20 20:44:09.022 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

   9  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:09.293 2009  to  Mon Apr 20 20:44:09.293 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  10  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:25.536 2009  to  Mon Apr 20 20:44:25.536 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  11  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:25.791 2009  to  Mon Apr 20 20:44:25.791 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  12  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:29.082 2009  to  Mon Apr 20 20:44:29.082 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  13  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:29.337 2009  to  Mon Apr 20 20:44:29.337 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  14  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:30.720 2009  to  Mon Apr 20 20:45:30.720 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  15  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:30.975 2009  to  Mon Apr 20 20:45:30.975 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  16  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.457 2009  to  Mon Apr 20 20:45:33.457 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  17  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.712 2009  to  Mon Apr 20 20:45:33.712 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  18  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.967 2009  to  Mon Apr 20 20:45:33.967 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  19  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:11.781 2009  to  Mon Apr 20 20:47:11.781 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.6004524e-04 -1.2693405e-03 -3.1501055e-03 -8.2340240e-03 -4.8542976e-02 2.3739457e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:12.038 2009  to  Mon Apr 20 20:47:12.038 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.6004524e-04 -1.2693405e-03 -3.1501055e-03 -8.2340240e-03 -4.8542976e-02 2.3739457e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:27.272 2009  to  Mon Apr 20 20:47:27.272 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  22  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:27.527 2009  to  Mon Apr 20 20:47:27.527 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  23  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.106 2009  to  Mon Apr 20 20:47:38.106 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 7.4446201e-05 -2.4385452e-03 -3.3154488e-03 -1.2439728e-02 7.8766823e-02 -2.8759360e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.361 2009  to  Mon Apr 20 20:47:38.361 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.615 2009  to  Mon Apr 20 20:47:38.615 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.870 2009  to  Mon Apr 20 20:47:38.870 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:39.529 2009  to  Mon Apr 20 20:47:39.529 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.392 2009  to  Mon Apr 20 20:47:40.392 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.646 2009  to  Mon Apr 20 20:47:40.646 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.901 2009  to  Mon Apr 20 20:47:40.901 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.0360641e-05 -1.8478632e-03 -3.3180714e-03 -2.1688461e-02 4.0013313e-02 -2.8906226e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:41.156 2009  to  Mon Apr 20 20:47:41.156 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.0360641e-05 -1.8478632e-03 -3.3180714e-03 -2.1688461e-02 4.0013313e-02 -2.8906226e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:41.411 2009  to  Mon Apr 20 20:47:41.411 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.7513199e-05 -2.4465322e-03 -3.3254623e-03 1.0652542e-02 3.9334297e-02 -7.4828863e-03

  33  SEQERROR  PSF        command.adjustPointing                                        Mon Apr 20 23:11:27.886 2009  to  Mon Apr 20 23:11:36.389 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 0.0000000e+00, tilt -3.0000000e+01

  34  SEQERROR  PSF        command.adjustPointing                                        Mon Apr 20 23:12:00.792 2009  to  Mon Apr 20 23:12:00.792 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 0.0000000e+00, tilt -5.0000000e+01

  35  FAILED    PSF        primaryMirror.command.revert                                  Mon Apr 20 23:45:44.485 2009  to  Mon Apr 20 23:45:51.032 2009   (  6.55) secs
                     left PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:45:48.785 2009  to  Mon Apr 20 23:45:50.975 2009   (  2.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:45:53.419 2009  to  Mon Apr 20 23:46:18.649 2009   ( 25.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  38  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Mon Apr 20 23:45:53.367 2009  to  Mon Apr 20 23:46:18.705 2009   ( 25.34) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

  39  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Apr 20 23:46:20.470 2009  to  Mon Apr 20 23:46:26.771 2009   (  6.30) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:46:20.523 2009  to  Mon Apr 20 23:46:26.714 2009   (  6.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon Apr 20 19:03:36.761 2009  to  Mon Apr 20 19:03:36.761 2009   (  0.00) secs
                     MJDsec from DSP is 4.746996250769176e+09 but t0 of the AZ target polynomial is 4.746984677429000e+09. Difference= 1.157334017562866e+04 seq=4770344

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Mon Apr 20 19:03:36.763 2009  to  Mon Apr 20 19:03:36.763 2009   (  0.00) secs
                     MJDsec from DSP is 4.746996250770908e+09 but t0 of the EL target polynomial is 4.746966806296000e+09. Difference= 2.944447490882874e+04 seq=4445031

   3  FAILED    PSF        command.setInstrumentOffsets                                  Mon Apr 20 19:14:30.397 2009  to  Mon Apr 20 19:14:32.794 2009   (  2.40) secs
                     left PSF SetInstrumentOffsets failed

   4  FAILED    IIF        command.moveFocus                                             Mon Apr 20 19:14:30.326 2009  to  Mon Apr 20 19:14:32.957 2009   (  2.63) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494209341435185e+04, time 3.458000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 3.530000000000000e-01

   5  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Apr 20 19:14:30.448 2009  to  Mon Apr 20 19:14:32.739 2009   (  2.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 19:14:30.564 2009  to  Mon Apr 20 19:14:32.619 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 19:14:30.501 2009  to  Mon Apr 20 19:14:32.684 2009   (  2.18) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.command.revert                                  Mon Apr 20 19:14:30.853 2009  to  Mon Apr 20 19:14:36.405 2009   (  5.55) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Apr 20 19:14:32.369 2009  to  Mon Apr 20 19:14:35.418 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Apr 20 19:14:32.310 2009  to  Mon Apr 20 19:14:35.357 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 19:14:33.167 2009  to  Mon Apr 20 19:14:36.349 2009   (  3.18) secs
                    Started event but no Complete event
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 19:14:33.228 2009  to  Mon Apr 20 19:14:36.285 2009   (  3.06) secs
                    Started event but no Complete event
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Apr 20 19:14:37.473 2009  to  Mon Apr 20 19:14:37.473 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror ChaseStop Command Complete

  14  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Apr 20 19:14:37.537 2009  to  Mon Apr 20 19:14:37.537 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror chaseStop complete

  15  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 19:37:44.543 2009  to  Mon Apr 20 19:37:44.543 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  16  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 19:37:44.491 2009  to  Mon Apr 20 19:37:44.491 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  17  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 19:37:44.595 2009  to  Mon Apr 20 19:37:44.595 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  18  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 20:19:34.440 2009  to  Mon Apr 20 20:19:34.440 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Mon Apr 20 20:19:34.491 2009  to  Mon Apr 20 20:19:34.491 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 20:29:13.172 2009  to  Mon Apr 20 20:29:13.172 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  21  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 20:29:13.119 2009  to  Mon Apr 20 20:29:13.119 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  22  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 20:29:13.224 2009  to  Mon Apr 20 20:29:13.224 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  23  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:09.022 2009  to  Mon Apr 20 20:44:09.022 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  24  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:09.293 2009  to  Mon Apr 20 20:44:09.293 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:25.536 2009  to  Mon Apr 20 20:44:25.536 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  26  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:25.791 2009  to  Mon Apr 20 20:44:25.791 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  27  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:29.082 2009  to  Mon Apr 20 20:44:29.082 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:44:29.337 2009  to  Mon Apr 20 20:44:29.337 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:30.720 2009  to  Mon Apr 20 20:45:30.720 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:30.975 2009  to  Mon Apr 20 20:45:30.975 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.457 2009  to  Mon Apr 20 20:45:33.457 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.712 2009  to  Mon Apr 20 20:45:33.712 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:45:33.967 2009  to  Mon Apr 20 20:45:33.967 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:11.781 2009  to  Mon Apr 20 20:47:11.781 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.6004524e-04 -1.2693405e-03 -3.1501055e-03 -8.2340240e-03 -4.8542976e-02 2.3739457e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:12.038 2009  to  Mon Apr 20 20:47:12.038 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -5.6004524e-04 -1.2693405e-03 -3.1501055e-03 -8.2340240e-03 -4.8542976e-02 2.3739457e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:27.272 2009  to  Mon Apr 20 20:47:27.272 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  37  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:27.527 2009  to  Mon Apr 20 20:47:27.527 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -4.9293041e-05 -1.5586615e-03 -3.1450987e-03 8.0146790e-03 -2.1304131e-02 2.7328730e-03

  38  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.106 2009  to  Mon Apr 20 20:47:38.106 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 7.4446201e-05 -2.4385452e-03 -3.3154488e-03 -1.2439728e-02 7.8766823e-02 -2.8759360e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.361 2009  to  Mon Apr 20 20:47:38.361 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.615 2009  to  Mon Apr 20 20:47:38.615 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:38.870 2009  to  Mon Apr 20 20:47:38.870 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.3845177e-04 -1.8398762e-03 -3.1301975e-03 1.1711121e-03 4.5371056e-02 -3.9550185e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:39.529 2009  to  Mon Apr 20 20:47:39.529 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.392 2009  to  Mon Apr 20 20:47:40.392 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.646 2009  to  Mon Apr 20 20:47:40.646 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 2.5296211e-04 -2.1450520e-03 -3.5008192e-03 -2.8293610e-02 6.1879158e-02 -3.9261222e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:40.901 2009  to  Mon Apr 20 20:47:40.901 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.0360641e-05 -1.8478632e-03 -3.3180714e-03 -2.1688461e-02 4.0013313e-02 -2.8906226e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:41.156 2009  to  Mon Apr 20 20:47:41.156 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.0360641e-05 -1.8478632e-03 -3.3180714e-03 -2.1688461e-02 4.0013313e-02 -2.8906226e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Mon Apr 20 20:47:41.411 2009  to  Mon Apr 20 20:47:41.411 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 9.7513199e-05 -2.4465322e-03 -3.3254623e-03 1.0652542e-02 3.9334297e-02 -7.4828863e-03

  48  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:11:21.468 2009  to  Mon Apr 20 21:11:21.468 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:11:21.519 2009  to  Mon Apr 20 21:11:21.519 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:14:03.743 2009  to  Mon Apr 20 21:14:03.743 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:14:03.795 2009  to  Mon Apr 20 21:14:03.795 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:28:49.608 2009  to  Mon Apr 20 21:28:49.608 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  53  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:28:49.660 2009  to  Mon Apr 20 21:28:49.660 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  54  FAILED    PMC        VxInterface.close                                             Mon Apr 20 21:59:09.381 2009  to  Mon Apr 20 21:59:09.381 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 21:59:09.329 2009  to  Mon Apr 20 21:59:09.329 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:09:17.288 2009  to  Mon Apr 20 22:09:17.288 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:09:17.236 2009  to  Mon Apr 20 22:09:17.236 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  58  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:15:40.730 2009  to  Mon Apr 20 22:15:40.730 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:15:40.677 2009  to  Mon Apr 20 22:15:40.677 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:32:19.225 2009  to  Mon Apr 20 22:32:19.225 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:32:19.277 2009  to  Mon Apr 20 22:32:19.277 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:45:31.803 2009  to  Mon Apr 20 22:45:31.803 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  63  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:45:31.855 2009  to  Mon Apr 20 22:45:31.855 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:50:28.158 2009  to  Mon Apr 20 22:50:28.158 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  65  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:50:28.210 2009  to  Mon Apr 20 22:50:28.210 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  66  FAILED    PMC        VxInterface.close                                             Mon Apr 20 22:55:26.565 2009  to  Mon Apr 20 22:55:26.565 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  67  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 22:55:26.512 2009  to  Mon Apr 20 22:55:26.512 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  68  SEQERROR  PSF        command.adjustPointing                                        Mon Apr 20 23:11:27.886 2009  to  Mon Apr 20 23:11:36.389 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF AdjustPointing started for tip 0.0000000e+00, tilt -3.0000000e+01

  69  SEQERROR  PSF        command.adjustPointing                                        Mon Apr 20 23:12:00.792 2009  to  Mon Apr 20 23:12:00.792 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF AdjustPointing complete for tip 0.0000000e+00, tilt -5.0000000e+01

  70  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:22:22.766 2009  to  Mon Apr 20 23:22:22.766 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:22:22.819 2009  to  Mon Apr 20 23:22:22.819 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:26:15.531 2009  to  Mon Apr 20 23:26:15.531 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  73  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:26:15.583 2009  to  Mon Apr 20 23:26:15.583 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  74  FAILED    PMC        VxInterface.close                                             Mon Apr 20 23:40:01.157 2009  to  Mon Apr 20 23:40:01.157 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  75  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 23:40:01.105 2009  to  Mon Apr 20 23:40:01.105 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  76  FAILED    PSF        primaryMirror.command.revert                                  Mon Apr 20 23:45:44.485 2009  to  Mon Apr 20 23:45:51.032 2009   (  6.55) secs
                     left PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

  77  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:45:48.851 2009  to  Mon Apr 20 23:45:50.907 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:45:48.785 2009  to  Mon Apr 20 23:45:50.975 2009   (  2.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  79  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:45:53.419 2009  to  Mon Apr 20 23:46:18.649 2009   ( 25.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  80  FAILED    PSF        primaryMirror.command.setPointingOffsets                      Mon Apr 20 23:45:53.367 2009  to  Mon Apr 20 23:46:18.705 2009   ( 25.34) secs
                     left PSF primary mirror setPointingOffsets failed because Primary mirror collimation failed

  81  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:45:53.484 2009  to  Mon Apr 20 23:46:18.583 2009   ( 25.10) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  82  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Apr 20 23:46:20.470 2009  to  Mon Apr 20 23:46:26.771 2009   (  6.30) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  83  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 23:46:20.523 2009  to  Mon Apr 20 23:46:26.714 2009   (  6.19) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  84  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 23:46:20.586 2009  to  Mon Apr 20 23:46:26.648 2009   (  6.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 23:54:44.598 2009  to  Mon Apr 20 23:54:44.598 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  86  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 23:54:44.705 2009  to  Mon Apr 20 23:54:44.705 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  87  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 23:54:44.652 2009  to  Mon Apr 20 23:54:44.652 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  88  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:03:16.193 2009  to  Tue Apr 21 00:03:16.193 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  89  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:03:16.245 2009  to  Tue Apr 21 00:03:16.245 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:20:11.290 2009  to  Tue Apr 21 00:20:11.290 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  91  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:20:11.238 2009  to  Tue Apr 21 00:20:11.238 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  92  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:40:03.758 2009  to  Tue Apr 21 00:40:03.758 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  93  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:40:03.809 2009  to  Tue Apr 21 00:40:03.809 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  94  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 00:40:40.652 2009  to  Tue Apr 21 00:40:40.652 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  95  FAILED    PMC        VxInterface.close                                             Tue Apr 21 00:40:40.705 2009  to  Tue Apr 21 00:40:40.705 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  96  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 00:50:50.930 2009  to  Tue Apr 21 00:50:50.930 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  97  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 00:50:50.873 2009  to  Tue Apr 21 00:50:50.873 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  98  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 00:50:50.983 2009  to  Tue Apr 21 00:50:50.983 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  99  FAILED    PMC        VxInterface.close                                             Tue Apr 21 01:13:08.309 2009  to  Tue Apr 21 01:13:08.309 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 100  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 01:13:08.257 2009  to  Tue Apr 21 01:13:08.257 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 101  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 01:13:43.851 2009  to  Tue Apr 21 01:13:43.939 2009   (  0.09) secs
                    

 102  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 02:47:19.096 2009  to  Tue Apr 21 02:47:19.096 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

 103  FAILED    PMC        VxInterface.close                                             Tue Apr 21 02:47:19.148 2009  to  Tue Apr 21 02:47:19.148 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 104  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 02:47:32.090 2009  to  Tue Apr 21 02:47:32.090 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 105  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 02:47:32.036 2009  to  Tue Apr 21 02:47:32.036 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 106  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 02:47:32.143 2009  to  Tue Apr 21 02:47:32.143 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 107  FAILED    PMC        VxInterface.lengthError                                       Tue Apr 21 02:52:17.451 2009  to  Tue Apr 21 02:52:17.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 108  FAILED    PMC        VxInterface.close                                             Tue Apr 21 02:52:17.503 2009  to  Tue Apr 21 02:52:17.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 109  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 03:00:32.742 2009  to  Tue Apr 21 03:00:32.795 2009   (  0.05) secs
                    

 110  SXDXBOTH  PCS        guider.command.enableGuiding                                  Tue Apr 21 03:06:17.643 2009  to  Tue Apr 21 03:06:17.695 2009   (  0.05) secs
                    

 111  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:20.439 2009  to  Tue Apr 21 03:21:23.501 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

 112  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:20.658 2009  to  Tue Apr 21 03:21:23.683 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 113  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:23.501 2009  to  Tue Apr 21 03:21:27.580 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

 114  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:27.763 2009  to  Tue Apr 21 03:21:31.831 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 115  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:39.953 2009  to  Tue Apr 21 03:21:39.953 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

 116  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:39.900 2009  to  Tue Apr 21 03:21:39.900 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

 117  SEQERROR  IIF        command.offset                                                Tue Apr 21 03:21:40.206 2009  to  Tue Apr 21 03:21:40.206 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

 118  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:21:40.152 2009  to  Tue Apr 21 03:21:40.152 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

 119  FAILED    IIF        command.preset.(TRACK)                                        Tue Apr 21 03:24:11.475 2009  to  Tue Apr 21 03:29:13.299 2009   (301.82) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494243348379630e+04, time 5.250000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

 120  SEQERROR  IIF        command.preset.elevationWait                                  Tue Apr 21 03:24:12.472 2009  to  Tue Apr 21 03:31:22.124 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

 121  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr 21 03:29:29.770 2009  to  Tue Apr 21 03:29:29.770 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 122  FAILED    IIF        command.offset                                                Tue Apr 21 03:38:39.612 2009  to  Tue Apr 21 03:43:40.720 2009   (301.11) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

 123  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Apr 21 03:38:39.996 2009  to  Tue Apr 21 04:14:44.510 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 124  FAILED    PMC        VxInterface.selectTimeout                                     Tue Apr 21 06:04:06.786 2009  to  Tue Apr 21 06:04:06.786 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 125  FAILED    PMC        thermal.badReceive                                            Tue Apr 21 06:04:06.896 2009  to  Tue Apr 21 06:04:06.896 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 126  FAILED    PMC        VxInterface.packetReadError                                   Tue Apr 21 06:04:06.842 2009  to  Tue Apr 21 06:04:06.842 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

**********************************************************
    Reporting period ending:   Tue Apr 21 06:12:55.642 2009
********************************************************************************************************