You are here: Foswiki>Software Web>TCSSWReportFile_090419 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Apr 19 2009 to Apr 20 2009
 
    Reporting period beginning:   Sun Apr 19 18:22:00.317 2009
    Reporting period ending:      Mon Apr 20 06:13:57.630 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.00    0.80    0.80    0.80   100.0 %          1          1                      
                                                                       0.00    0.80    0.80    0.80

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.11   100.0 %         76         76                      
                                                                       0.01    0.05    0.05    0.11
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.28    0.51    0.24    1.63   100.0 %        408        408                      
                                                                       0.28    0.51    0.24    1.63
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.69    5.46    2.52   31.60    99.6 %        246        245          1           
                                                                       4.70    5.45    2.52   31.60
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.39    4.83    2.98   11.05   100.0 %        110        110                      
                                                                       1.39    4.83    2.98   11.05
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.51    3.98    2.05   10.27   100.0 %        110        110                      
                                                                       1.51    3.98    2.05   10.27
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   16.86   11.05    1.05   50.15   100.0 %         22         22                      
                                                                      16.86   11.05    1.05   50.15
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   49.37   26.35    1.06  166.36   100.0 %         21         21                      
                                                                      49.37   26.35    1.06  166.36
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   73.48   52.09    6.94  261.17    95.5 %         22         21          1           
                                                                      74.80   53.89    6.94  261.17
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    2.20    4.06    0.64   19.92   100.0 %        983        983                      
                                                                       2.20    4.06    0.64   19.92
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    0.69    2.95    2.50    4.58   100.0 %         20         20                      
                                                                       0.69    2.95    2.50    4.58

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             6

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Sun Apr 19 19:17:31.040 2009  to  Sun Apr 19 19:17:38.784 2009   (  7.74) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494109550925926e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

   2  FAILED    IIF        command.preset.(TRACK)                                        Mon Apr 20 00:37:05.955 2009  to  Mon Apr 20 00:37:20.271 2009   ( 14.32) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494131746527777e+04, time 5.700000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3528                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7055                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      33                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         26                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                          
      Nothing to report

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            10
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      48                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     242                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     322                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     954                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun Apr 19 19:06:21.347 2009  to  Sun Apr 19 19:06:21.347 2009   (  0.00) secs
                     MJDsec from DSP is 4.746910015346698e+09 but t0 of the AZ target polynomial is 4.746907219858000e+09. Difference= 2.795488698005676e+03 seq=3253751

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun Apr 19 19:06:21.348 2009  to  Sun Apr 19 19:06:21.348 2009   (  0.00) secs
                     MJDsec from DSP is 4.746910015347677e+09 but t0 of the EL target polynomial is 4.746883420793000e+09. Difference= 2.659455467700958e+04 seq=2837892
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.09    0.21    0.11    0.54   100.0 %        408        408                      
                                                                       0.09    0.21    0.11    0.54
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.25    0.47    0.05    0.97   100.0 %        110        110                      
                                                                       0.25    0.47    0.05    0.97
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %         24         24                      
                                                                       0.00    0.06    0.05    0.06
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.19    0.58    0.31    0.88   100.0 %         24         24                      
                                                                       0.19    0.58    0.31    0.88
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.00    0.11    0.11    0.11   100.0 %          1          1                      
                                                                       0.00    0.11    0.11    0.11

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.11    2.99    2.05    6.07   100.0 %         74         74                      
                                                                       1.11    2.99    2.05    6.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          3          3                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.09    3.95    2.05   52.15    99.8 %       1207       1205          2           
                                                                       4.09    3.94    2.05   52.15
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .                                    99.8 %                                1           
                                                                                                   

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       3                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            41
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            33
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      74                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 41           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 41           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      41                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  4           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           

PMC Events of Interest

   1  SEQERROR  PMC        mirror.command.raise.auto                                     Sun Apr 19 18:24:31.429 2009  to  Sun Apr 19 18:24:31.429 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror AutoRaise Command Complete

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Apr 19 19:17:31.368 2009  to  Sun Apr 19 19:17:38.437 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:11:20.592 2009  to  Sun Apr 19 20:11:20.592 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   4  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:11:20.645 2009  to  Sun Apr 19 20:11:20.645 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:32:08.619 2009  to  Sun Apr 19 20:32:08.619 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:32:08.672 2009  to  Sun Apr 19 20:32:08.672 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   7  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:45:57.145 2009  to  Sun Apr 19 20:45:57.145 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:45:57.092 2009  to  Sun Apr 19 20:45:57.092 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:50:17.889 2009  to  Sun Apr 19 20:50:17.889 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:50:17.837 2009  to  Sun Apr 19 20:50:17.837 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:58:26.663 2009  to  Sun Apr 19 20:58:26.663 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:58:26.716 2009  to  Sun Apr 19 20:58:26.716 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.close                                             Sun Apr 19 21:41:42.121 2009  to  Sun Apr 19 21:41:42.121 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 21:41:42.069 2009  to  Sun Apr 19 21:41:42.069 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 21:51:36.778 2009  to  Sun Apr 19 21:51:36.778 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Sun Apr 19 21:51:36.830 2009  to  Sun Apr 19 21:51:36.830 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.packetReadError                                   Sun Apr 19 21:54:30.800 2009  to  Sun Apr 19 21:54:30.800 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  18  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 21:54:30.747 2009  to  Sun Apr 19 21:54:30.747 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  19  FAILED    PMC        thermal.badReceive                                            Sun Apr 19 21:54:30.852 2009  to  Sun Apr 19 21:54:30.852 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  20  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:29:56.783 2009  to  Sun Apr 19 22:29:56.783 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:29:56.730 2009  to  Sun Apr 19 22:29:56.730 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  22  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:18.478 2009  to  Sun Apr 19 22:41:18.478 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  23  FAILED    PMC        VxInterface.packetReadError                                   Sun Apr 19 22:41:18.530 2009  to  Sun Apr 19 22:41:18.530 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

  24  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:18.885 2009  to  Sun Apr 19 22:41:18.885 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  25  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:19.287 2009  to  Sun Apr 19 22:41:19.287 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  26  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:19.638 2009  to  Sun Apr 19 22:41:19.638 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  27  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:43:46.205 2009  to  Sun Apr 19 22:43:46.205 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  28  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:43:46.257 2009  to  Sun Apr 19 22:43:46.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  29  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:48:57.158 2009  to  Sun Apr 19 22:48:57.158 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  30  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:48:57.210 2009  to  Sun Apr 19 22:48:57.210 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:50:54.740 2009  to  Sun Apr 19 22:50:54.740 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:50:54.793 2009  to  Sun Apr 19 22:50:54.793 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:53:29.317 2009  to  Sun Apr 19 22:53:29.317 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:53:29.369 2009  to  Sun Apr 19 22:53:29.369 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:15:58.713 2009  to  Sun Apr 19 23:15:58.713 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:15:58.766 2009  to  Sun Apr 19 23:15:58.766 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:22:51.803 2009  to  Sun Apr 19 23:22:51.803 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:22:51.751 2009  to  Sun Apr 19 23:22:51.751 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:24:37.287 2009  to  Sun Apr 19 23:24:37.287 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:24:37.235 2009  to  Sun Apr 19 23:24:37.235 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:51:00.296 2009  to  Sun Apr 19 23:51:00.296 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:51:00.348 2009  to  Sun Apr 19 23:51:00.348 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:12:53.350 2009  to  Mon Apr 20 00:12:53.350 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  44  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:12:53.298 2009  to  Mon Apr 20 00:12:53.298 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:28:11.760 2009  to  Mon Apr 20 00:28:11.760 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  46  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:28:11.811 2009  to  Mon Apr 20 00:28:11.811 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  47  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 00:37:08.963 2009  to  Mon Apr 20 00:37:20.037 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  48  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:39:42.256 2009  to  Mon Apr 20 00:39:42.256 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:39:42.307 2009  to  Mon Apr 20 00:39:42.307 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:41:16.941 2009  to  Mon Apr 20 00:41:16.941 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:41:16.994 2009  to  Mon Apr 20 00:41:16.994 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:58:13.088 2009  to  Mon Apr 20 00:58:13.088 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:58:13.140 2009  to  Mon Apr 20 00:58:13.140 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:59:33.229 2009  to  Mon Apr 20 00:59:33.229 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:59:33.176 2009  to  Mon Apr 20 00:59:33.176 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:10:27.777 2009  to  Mon Apr 20 01:10:27.777 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:10:27.829 2009  to  Mon Apr 20 01:10:27.829 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:10:59.924 2009  to  Mon Apr 20 01:10:59.924 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:10:59.872 2009  to  Mon Apr 20 01:10:59.872 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:13:48.999 2009  to  Mon Apr 20 01:13:48.999 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:13:48.947 2009  to  Mon Apr 20 01:13:48.947 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  62  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 02:39:58.394 2009  to  Mon Apr 20 02:39:58.394 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  63  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 02:39:58.499 2009  to  Mon Apr 20 02:39:58.499 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  64  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 02:39:58.446 2009  to  Mon Apr 20 02:39:58.446 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  65  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 03:47:28.505 2009  to  Mon Apr 20 03:47:28.505 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  66  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 03:47:28.452 2009  to  Mon Apr 20 03:47:28.452 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  67  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 03:47:28.557 2009  to  Mon Apr 20 03:47:28.557 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.adjustPointing . . . . . . . . . . . . . . . . . . . .    0.00   11.42   11.42   11.42   100.0 %          1          1                      
                                                                       0.00   11.42   11.42   11.42
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.20    3.81    0.40   19.63   100.0 %        983        983                      
                                                                       2.20    3.81    0.40   19.63
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %         44         44                      
                                                                       0.01    0.05    0.04    0.11
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.56    5.13    2.39   31.47    99.6 %        266        265          1           
                                                                       4.57    5.13    2.39   31.47
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.20    3.92    0.51   19.73   100.0 %        983        983                      
                                                                       2.20    3.92    0.51   19.73
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.20    3.59    0.19   19.41   100.0 %        983        983                      
                                                                       2.20    3.59    0.19   19.41
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.09    4.08    2.17   52.29    99.8 %       1207       1205          2           
                                                                       4.09    4.08    2.17   52.29
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    2.19    2.19    2.19   100.0 %          3          3                      
                                                                       0.00    2.19    2.19    2.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.05    0.10    0.07    0.52   100.0 %        112        112                      
                                                                       0.05    0.10    0.07    0.52
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.03    0.07    0.06    0.09   100.0 %          2          2                      
                                                                       0.03    0.07    0.06    0.09
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   28.39   24.61    4.54   44.69   100.0 %          2          2                      
                                                                      28.39   24.61    4.54   44.69
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.56    5.02    2.28   31.36    99.6 %        266        265          1           
                                                                       4.57    5.02    2.28   31.36
     primaryMirror.command.setPointingOffsets . . . . . . . . . . .    0.00   11.31   11.31   11.31   100.0 %          1          1                      
                                                                       0.00   11.31   11.31   11.31
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    2.30    2.30    2.30   100.0 %          1          1                      
                                                                       0.00    2.30    2.30    2.30
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.11   100.0 %        983        983                      
                                                                       0.00    0.05    0.05    0.11

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        command.setInstrumentOffsets                                  Sun Apr 19 19:17:31.192 2009  to  Sun Apr 19 19:17:38.613 2009   (  7.42) secs
                     right PSF SetInstrumentOffsets failed

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Apr 19 19:17:31.298 2009  to  Sun Apr 19 19:17:38.501 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Apr 19 19:17:31.245 2009  to  Sun Apr 19 19:17:38.557 2009   (  7.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 00:37:08.893 2009  to  Mon Apr 20 00:37:20.102 2009   ( 11.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  SEQERROR  PMC        mirror.command.raise.auto                                     Sun Apr 19 18:24:31.429 2009  to  Sun Apr 19 18:24:31.429 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror AutoRaise Command Complete

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun Apr 19 19:06:21.347 2009  to  Sun Apr 19 19:06:21.347 2009   (  0.00) secs
                     MJDsec from DSP is 4.746910015346698e+09 but t0 of the AZ target polynomial is 4.746907219858000e+09. Difference= 2.795488698005676e+03 seq=3253751

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sun Apr 19 19:06:21.348 2009  to  Sun Apr 19 19:06:21.348 2009   (  0.00) secs
                     MJDsec from DSP is 4.746910015347677e+09 but t0 of the EL target polynomial is 4.746883420793000e+09. Difference= 2.659455467700958e+04 seq=2837892

   4  FAILED    IIF        command.moveFocus                                             Sun Apr 19 19:17:31.040 2009  to  Sun Apr 19 19:17:38.784 2009   (  7.74) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494109550925926e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

   5  FAILED    PSF        command.setInstrumentOffsets                                  Sun Apr 19 19:17:31.192 2009  to  Sun Apr 19 19:17:38.613 2009   (  7.42) secs
                     right PSF SetInstrumentOffsets failed

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Apr 19 19:17:31.298 2009  to  Sun Apr 19 19:17:38.501 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Apr 19 19:17:31.245 2009  to  Sun Apr 19 19:17:38.557 2009   (  7.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Apr 19 19:17:31.368 2009  to  Sun Apr 19 19:17:38.437 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:11:20.592 2009  to  Sun Apr 19 20:11:20.592 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:11:20.645 2009  to  Sun Apr 19 20:11:20.645 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  11  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:32:08.619 2009  to  Sun Apr 19 20:32:08.619 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:32:08.672 2009  to  Sun Apr 19 20:32:08.672 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:45:57.145 2009  to  Sun Apr 19 20:45:57.145 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:45:57.092 2009  to  Sun Apr 19 20:45:57.092 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:50:17.889 2009  to  Sun Apr 19 20:50:17.889 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:50:17.837 2009  to  Sun Apr 19 20:50:17.837 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 20:58:26.663 2009  to  Sun Apr 19 20:58:26.663 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Sun Apr 19 20:58:26.716 2009  to  Sun Apr 19 20:58:26.716 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.close                                             Sun Apr 19 21:41:42.121 2009  to  Sun Apr 19 21:41:42.121 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 21:41:42.069 2009  to  Sun Apr 19 21:41:42.069 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 21:51:36.778 2009  to  Sun Apr 19 21:51:36.778 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Sun Apr 19 21:51:36.830 2009  to  Sun Apr 19 21:51:36.830 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.packetReadError                                   Sun Apr 19 21:54:30.800 2009  to  Sun Apr 19 21:54:30.800 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  24  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 21:54:30.747 2009  to  Sun Apr 19 21:54:30.747 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  25  FAILED    PMC        thermal.badReceive                                            Sun Apr 19 21:54:30.852 2009  to  Sun Apr 19 21:54:30.852 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  26  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:29:56.783 2009  to  Sun Apr 19 22:29:56.783 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:29:56.730 2009  to  Sun Apr 19 22:29:56.730 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  28  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:18.478 2009  to  Sun Apr 19 22:41:18.478 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  29  FAILED    PMC        VxInterface.packetReadError                                   Sun Apr 19 22:41:18.530 2009  to  Sun Apr 19 22:41:18.530 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

  30  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:18.885 2009  to  Sun Apr 19 22:41:18.885 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  31  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:19.287 2009  to  Sun Apr 19 22:41:19.287 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  32  FAILED    PMC        VxInterface.selectTimeout                                     Sun Apr 19 22:41:19.638 2009  to  Sun Apr 19 22:41:19.638 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  33  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:43:46.205 2009  to  Sun Apr 19 22:43:46.205 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:43:46.257 2009  to  Sun Apr 19 22:43:46.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:48:57.158 2009  to  Sun Apr 19 22:48:57.158 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:48:57.210 2009  to  Sun Apr 19 22:48:57.210 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:50:54.740 2009  to  Sun Apr 19 22:50:54.740 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:50:54.793 2009  to  Sun Apr 19 22:50:54.793 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 22:53:29.317 2009  to  Sun Apr 19 22:53:29.317 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Sun Apr 19 22:53:29.369 2009  to  Sun Apr 19 22:53:29.369 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:15:58.713 2009  to  Sun Apr 19 23:15:58.713 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:15:58.766 2009  to  Sun Apr 19 23:15:58.766 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:22:51.803 2009  to  Sun Apr 19 23:22:51.803 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  44  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:22:51.751 2009  to  Sun Apr 19 23:22:51.751 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:24:37.287 2009  to  Sun Apr 19 23:24:37.287 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:24:37.235 2009  to  Sun Apr 19 23:24:37.235 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  47  FAILED    PMC        VxInterface.lengthError                                       Sun Apr 19 23:51:00.296 2009  to  Sun Apr 19 23:51:00.296 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Sun Apr 19 23:51:00.348 2009  to  Sun Apr 19 23:51:00.348 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:12:53.350 2009  to  Mon Apr 20 00:12:53.350 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:12:53.298 2009  to  Mon Apr 20 00:12:53.298 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:28:11.760 2009  to  Mon Apr 20 00:28:11.760 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  52  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:28:11.811 2009  to  Mon Apr 20 00:28:11.811 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  53  FAILED    IIF        command.preset.(TRACK)                                        Mon Apr 20 00:37:05.955 2009  to  Mon Apr 20 00:37:20.271 2009   ( 14.32) secs
                     IIF GetTrajectory command started for both LBC, start time 5.494131746527777e+04, time 5.700000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Apr 20 00:37:08.893 2009  to  Mon Apr 20 00:37:20.102 2009   ( 11.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Apr 20 00:37:08.963 2009  to  Mon Apr 20 00:37:20.037 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:39:42.256 2009  to  Mon Apr 20 00:39:42.256 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:39:42.307 2009  to  Mon Apr 20 00:39:42.307 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:41:16.941 2009  to  Mon Apr 20 00:41:16.941 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  59  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:41:16.994 2009  to  Mon Apr 20 00:41:16.994 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:58:13.088 2009  to  Mon Apr 20 00:58:13.088 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:58:13.140 2009  to  Mon Apr 20 00:58:13.140 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.close                                             Mon Apr 20 00:59:33.229 2009  to  Mon Apr 20 00:59:33.229 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  63  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 00:59:33.176 2009  to  Mon Apr 20 00:59:33.176 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:10:27.777 2009  to  Mon Apr 20 01:10:27.777 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:10:27.829 2009  to  Mon Apr 20 01:10:27.829 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:10:59.924 2009  to  Mon Apr 20 01:10:59.924 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  67  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:10:59.872 2009  to  Mon Apr 20 01:10:59.872 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  68  FAILED    PMC        VxInterface.close                                             Mon Apr 20 01:13:48.999 2009  to  Mon Apr 20 01:13:48.999 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  69  FAILED    PMC        VxInterface.lengthError                                       Mon Apr 20 01:13:48.947 2009  to  Mon Apr 20 01:13:48.947 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  70  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 02:39:58.394 2009  to  Mon Apr 20 02:39:58.394 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  71  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 02:39:58.499 2009  to  Mon Apr 20 02:39:58.499 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  72  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 02:39:58.446 2009  to  Mon Apr 20 02:39:58.446 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  73  FAILED    PMC        VxInterface.packetReadError                                   Mon Apr 20 03:47:28.505 2009  to  Mon Apr 20 03:47:28.505 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  74  FAILED    PMC        VxInterface.selectTimeout                                     Mon Apr 20 03:47:28.452 2009  to  Mon Apr 20 03:47:28.452 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  75  FAILED    PMC        thermal.badReceive                                            Mon Apr 20 03:47:28.557 2009  to  Mon Apr 20 03:47:28.557 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

**********************************************************
    Reporting period ending:   Mon Apr 20 06:13:57.630 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback