             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.Tracker.timeDisparity,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   11.82    6.68    0.43   24.39   100.0 %          4          4                      
                                                                      11.82    6.68    0.43   24.39

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command. . . . . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                                              notAuthorized =     1
                                                                                                   
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.07    18.2 %         11          2          9           
                                                                       0.00    0.05    0.05    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.14    0.33    0.25    0.81   100.0 %         31         31                      
                                                                       0.14    0.33    0.25    0.81
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.84    5.39    2.53   34.60   100.0 %         30         30                      
                                                                       5.84    5.39    2.53   34.60
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.51    6.81    2.35    8.31   100.0 %         12         12                      
                                                                       1.51    6.81    2.35    8.31
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.44    3.30    2.07    3.66   100.0 %         12         12                      
                                                                       0.44    3.30    2.07    3.66
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   57.36   57.82    1.38  234.56    85.7 %         21         18          3           
                                                                      56.72   67.21   25.10  234.56
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   56.29   82.64   37.85  177.37    57.1 %          7          2          3          2
                                                                       4.87   41.29   37.85   44.74
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   10.92    8.14    1.05   45.13   100.0 %         35         35                      
                                                                      10.92    8.14    1.05   45.13
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   30.86   72.23   50.41   94.05     0.0 %          2                     2           
                                                                                                   
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   41.87   24.56    2.07  193.41   100.0 %         35         35                      
                                                                      41.87   24.56    2.07  193.41
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   41.69   48.74    1.91  118.72    88.9 %          9          7          1          1
                                                                      40.12   55.43    9.79  118.72

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             8

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 16 18:21:04.596 2009  to  Thu Apr 16 18:22:11.595 2009   ( 67.00) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   2  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 16 18:24:17.202 2009  to  Thu Apr 16 18:25:43.456 2009   ( 86.25) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   3  FAILED    IIF        command.preset.(TRACK)                                        Thu Apr 16 18:33:11.342 2009  to  Thu Apr 16 18:33:13.256 2009   (  1.91) secs
                     IIF Preset command started for both LBC mode TRACK from IIF
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly:LOW EL = -1.854979e-02 rad. Too low.
                     IIF Preset command failed for both LBC mode TRACK from IIF

   4  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:16.353 2009  to  Fri Apr 17 00:41:16.427 2009   (  0.07) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

   5  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:17.492 2009  to  Fri Apr 17 00:41:17.545 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

   6  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:18.612 2009  to  Fri Apr 17 00:41:18.665 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

   7  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:18.732 2009  to  Fri Apr 17 00:41:18.785 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

   8  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:19.852 2009  to  Fri Apr 17 00:41:19.904 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

   9  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:20.972 2009  to  Fri Apr 17 00:41:21.025 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  10  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:21.092 2009  to  Fri Apr 17 00:41:21.145 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  11  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:22.274 2009  to  Fri Apr 17 00:41:22.326 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  12  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:23.412 2009  to  Fri Apr 17 00:41:23.464 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  13  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 17 01:09:03.108 2009  to  Fri Apr 17 01:12:00.476 2009   (177.37) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  14  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr 17 02:40:24.474 2009  to  Fri Apr 17 02:41:14.880 2009   ( 50.41) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  15  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr 17 02:45:21.383 2009  to  Fri Apr 17 02:46:55.435 2009   ( 94.05) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 40
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  16  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 02:54:44.958 2009  to  Fri Apr 17 02:54:46.626 2009   (  1.67) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  17  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 02:56:10.760 2009  to  Fri Apr 17 02:56:12.141 2009   (  1.38) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  18  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 03:04:41.806 2009  to  Fri Apr 17 03:04:43.242 2009   (  1.44) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.off. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.command.on . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.controlValve.command.resetAlarm. . . . . . . . . . . .                                   100.0 %                                1           
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3608                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7216                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    14                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.defrostHeater.command.run . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.defrostHeater.command.setState. . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     314                      

ECS Events of Interest

   1  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Apr 16 22:55:18.353 2009  to  Thu Apr 16 22:55:18.353 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    9.46    7.66    0.00   23.26    88.9 %          9          5          1          2
                                                                       9.70    9.20    0.00   23.26
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    5.38    3.53    0.00   11.85    60.0 %          9         10          4           
                                                                       0.44    0.26    0.00    1.43
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    0.14    8.22    8.05    8.38   100.0 %          4          4                      
                                                                       0.14    8.22    8.05    8.38
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    7.74   20.61   14.65   43.24   100.0 %         27         27                      
                                                                       7.74   20.61   14.65   43.24
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %         18                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.03    0.08    0.06    0.11   100.0 %          4          4                      
                                                                       0.03    0.08    0.06    0.11
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.04    0.07    0.05    0.23   100.0 %         18         18                      
                                                                       0.04    0.07    0.05    0.23
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    0.77    0.86    0.37    1.99     8.7 %         46          4                      
                                                                       0.77    0.86    0.37    1.99
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.19    0.30    0.16    0.55   100.0 %          4          4                      
                                                                       0.19    0.30    0.16    0.55
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    5.02   11.43    6.86   27.77   100.0 %         27         27                      
                                                                       5.02   11.43    6.86   27.77
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.07    3.29    2.18    6.72    98.4 %        193        190                        interrupted =     3
                                                                       1.07    3.29    2.18    6.72
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    0.07   32.41   32.33   32.56    84.2 %         19         16                        interrupted =     3
                                                                       0.07   32.41   32.33   32.56
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.03    0.20    0.16    0.29   100.0 %         27         27                      
                                                                       0.03    0.20    0.16    0.29
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.09    0.21    0.16    0.93   100.0 %        178        178                      
                                                                       0.09    0.21    0.16    0.93
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.60    2.08    1.23    2.81   100.0 %          5          5                      
                                                                       0.60    2.08    1.23    2.81
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . . 1261.36  330.28   10.87 5060.30   100.0 %         16         16                      
                                                                    1261.36  330.28   10.87 5060.30
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.80    7.56    6.45    8.93   100.0 %         16         16                      
                                                                       0.80    7.56    6.45    8.93

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .       5                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .       4                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                            33
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .       4                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .       5                      

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 16 18:21:59.733 2009  to  Thu Apr 16 18:22:11.307 2009   ( 11.57) secs
                     couldn''t find a star in any GS location.

   2  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 16 18:25:31.643 2009  to  Thu Apr 16 18:25:43.270 2009   ( 11.63) secs
                     couldn''t find a star in any GS location.

   3  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 17 01:11:48.524 2009  to  Fri Apr 17 01:12:00.294 2009   ( 11.77) secs
                     couldn''t find a star in any GS location.

   4  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 17 02:41:02.852 2009  to  Fri Apr 17 02:41:14.698 2009   ( 11.85) secs
                     couldn''t find a star in any GS location.

   5  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr 17 02:46:54.930 2009  to  Fri Apr 17 02:46:54.930 2009   (  0.00) secs
                     guiding was not stable within 6 cycles
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       9                      
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      10                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      75                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      36                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      29                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      27                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     456                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    2416                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     808                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            76
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     312                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  9           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .       4          3          1
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      55                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      13                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            15
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             8
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       4                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  3           
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      46                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      41                      
     MCSPU.RTracker.commandToVelMode. . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      26                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rSoftFailureClearAll. . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cSoftFailureClearAll. . . . . . . . . . . . . .       1                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 16 18:30:43.450 2009  to  Thu Apr 16 18:30:43.450 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 16 18:30:43.459 2009  to  Thu Apr 16 18:30:43.459 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 16 18:30:44.471 2009  to  Thu Apr 16 18:30:44.471 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

   4  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 16 18:35:22.705 2009  to  Thu Apr 16 18:35:22.705 2009   (  0.00) secs
                    

   5  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Apr 16 19:34:57.925 2009  to  Thu Apr 16 19:34:57.925 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   6  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Apr 16 19:34:57.926 2009  to  Thu Apr 16 19:34:57.926 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   7  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Apr 16 23:14:37.227 2009  to  Thu Apr 16 23:14:37.227 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 00:40:02.313 2009  to  Fri Apr 17 00:40:02.313 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 00:40:02.340 2009  to  Fri Apr 17 00:40:02.340 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  10  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.379 2009  to  Fri Apr 17 00:45:07.379 2009   (  0.00) secs
                    

  11  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.381 2009  to  Fri Apr 17 00:45:07.381 2009   (  0.00) secs
                    

  12  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.383 2009  to  Fri Apr 17 00:45:07.383 2009   (  0.00) secs
                    

  13  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Fri Apr 17 02:56:35.614 2009  to  Fri Apr 17 02:56:35.614 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 1.010072e+00 seconds in the past!

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 02:56:35.617 2009  to  Fri Apr 17 02:56:35.617 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:23.195 2009  to  Fri Apr 17 03:03:23.195 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:23.202 2009  to  Fri Apr 17 03:03:23.202 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr 17 03:03:23.299 2009  to  Fri Apr 17 03:03:23.299 2009   (  0.00) secs
                     drive cabinet has turned on.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.319 2009  to  Fri Apr 17 03:03:24.319 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.321 2009  to  Fri Apr 17 03:03:24.321 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:51.012 2009  to  Fri Apr 17 03:03:51.012 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:51.017 2009  to  Fri Apr 17 03:03:51.017 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Apr 17 03:03:51.976 2009  to  Fri Apr 17 03:03:51.976 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Fri Apr 17 03:03:54.531 2009  to  Fri Apr 17 03:03:54.531 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 4.540564e+00 seconds in the past!

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.539 2009  to  Fri Apr 17 03:03:54.539 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468534849e+09 but t0 of the AZ target polynomial is 4.746679463991000e+09. Difference= 4.543848991394043e+00 seq=676573

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.539 2009  to  Fri Apr 17 03:03:54.539 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468535529e+09 but t0 of the EL target polynomial is 4.746679463991000e+09. Difference= 4.544528961181641e+00 seq=676573

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.541 2009  to  Fri Apr 17 03:03:54.541 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468486069e+09 but t0 of the LFBG target polynomial is 4.746679463941000e+09. Difference= 4.545068740844727e+00 seq=231665

  33  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Fri Apr 17 03:05:13.629 2009  to  Fri Apr 17 03:05:13.629 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  34  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr 17 03:05:15.361 2009  to  Fri Apr 17 03:05:15.361 2009   (  0.00) secs
                     A brake command failed to complete successfully.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    3.94    5.20    2.16   22.20   100.0 %         54         54                      
                                                                       3.94    5.20    2.16   22.20
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    5.76    4.91    2.68   27.90   100.0 %         27         27                      
                                                                       5.76    4.91    2.68   27.90
     side[0].tertiary_mirror.getfocalstationcount.command . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.00   22.89   22.89   22.89   100.0 %          1          1                      
                                                                       0.00   22.89   22.89   22.89
     side[0].tertiary_mirror.moveselabs.command . . . . . . . . . .    0.00   13.37   13.37   13.37   100.0 %          1          1                      
                                                                       0.00   13.37   13.37   13.37

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             4

OSS Events of Interest

   1  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu Apr 16 18:22:48.549 2009  to  Thu Apr 16 18:22:48.549 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

   2  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu Apr 16 18:22:51.000 2009  to  Thu Apr 16 18:22:51.000 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.05    0.04    0.06   100.0 %         27         27                      
                                                                       0.00    0.05    0.04    0.06
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.05    0.04    0.10   100.0 %        178        178                      
                                                                       0.01    0.05    0.04    0.10
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.58    1.92    1.11    2.62   100.0 %          5          5                        largeUpdate =     5
                                                                       0.58    1.92    1.11    2.62
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.14    0.11    0.22   100.0 %         31         31                      
                                                                       0.03    0.14    0.11    0.22
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.01    0.05    0.04    0.11   100.0 %        289        289                      
                                                                       0.01    0.05    0.04    0.11
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.01    0.06    0.05    0.08   100.0 %         12         12                      
                                                                       0.01    0.06    0.05    0.08
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.12   100.0 %        359        359                      
                                                                       0.01    0.05    0.04    0.12
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.07    0.07    0.05    0.51   100.0 %         39         39                      
                                                                       0.07    0.07    0.05    0.51
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.02    0.38    0.37    0.39   100.0 %          2          2                      
                                                                       0.02    0.38    0.37    0.39
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.22    0.55    0.31    1.07    89.7 %         39         35          4           
                                                                       0.20    0.53    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.05    0.00    0.11   100.0 %          4          4                      
                                                                       0.04    0.07    0.03    0.11

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 16 18:30:42.243 2009  to  Thu Apr 16 18:30:42.381 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   2  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 16 18:30:42.521 2009  to  Thu Apr 16 18:30:42.521 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   3  FAILED    PCS        telescope.command.startTracking                               Thu Apr 16 18:33:11.924 2009  to  Thu Apr 16 18:33:12.989 2009   (  1.07) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly:LOW EL = -1.854979e-02 rad. Too low.

   4  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 02:54:45.637 2009  to  Fri Apr 17 02:54:46.455 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

   5  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 02:56:11.405 2009  to  Fri Apr 17 02:56:11.971 2009   (  0.57) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

   6  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 03:04:42.518 2009  to  Fri Apr 17 03:04:43.080 2009   (  0.56) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.00    2.06    2.06    2.07   100.0 %         13         13                      
                                                                       0.00    2.06    2.06    2.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          5          5                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    9.87    8.44    2.06   47.14   100.0 %         99         99                      
                                                                       9.87    8.44    2.06   47.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       8                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             5
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             8
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  1           
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  3           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       5                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            19
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      13                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      

PMC Events of Interest

   1  FAILED    PMC        VxInterface.close                                             Thu Apr 16 18:33:15.100 2009  to  Thu Apr 16 18:33:15.100 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   2  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 18:33:15.048 2009  to  Thu Apr 16 18:33:15.048 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   3  FAILED    PMC        actuator.forceMonitor1.panic                                  Thu Apr 16 18:35:58.005 2009  to  Thu Apr 16 18:35:58.005 2009   (  0.00) secs
                     left PMC Actuator 316 force monitor 1 PANIC! -282.0 lbs, limit is -114.2

   4  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 16 18:40:34.011 2009  to  Thu Apr 16 18:40:34.011 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   5  FAILED    PMC        thermal.badReceive                                            Thu Apr 16 18:40:34.117 2009  to  Thu Apr 16 18:40:34.117 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   6  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 16 18:40:34.064 2009  to  Thu Apr 16 18:40:34.064 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   7  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 16 19:25:38.939 2009  to  Thu Apr 16 19:25:38.939 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   8  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 16 19:25:38.885 2009  to  Thu Apr 16 19:25:38.885 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   9  FAILED    PMC        thermal.badReceive                                            Thu Apr 16 19:25:38.991 2009  to  Thu Apr 16 19:25:38.991 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  10  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 19:25:47.217 2009  to  Thu Apr 16 19:25:47.217 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  11  FAILED    PMC        VxInterface.close                                             Thu Apr 16 19:25:47.269 2009  to  Thu Apr 16 19:25:47.269 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  12  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:23:52.090 2009  to  Thu Apr 16 23:23:52.090 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:23:52.038 2009  to  Thu Apr 16 23:23:52.038 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:27:21.458 2009  to  Thu Apr 16 23:27:21.458 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:27:21.405 2009  to  Thu Apr 16 23:27:21.405 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:30:08.184 2009  to  Thu Apr 16 23:30:08.184 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  17  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:30:08.236 2009  to  Thu Apr 16 23:30:08.236 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:33:17.257 2009  to  Thu Apr 16 23:33:17.257 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:33:17.310 2009  to  Thu Apr 16 23:33:17.310 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:42:28.668 2009  to  Thu Apr 16 23:42:28.668 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:42:28.720 2009  to  Thu Apr 16 23:42:28.720 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Fri Apr 17 00:58:02.407 2009  to  Fri Apr 17 00:58:02.407 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Fri Apr 17 00:58:02.459 2009  to  Fri Apr 17 00:58:02.459 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 17 05:39:58.489 2009  to  Fri Apr 17 05:39:58.489 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  25  FAILED    PMC        thermal.badReceive                                            Fri Apr 17 05:39:58.593 2009  to  Fri Apr 17 05:39:58.593 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  26  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 17 05:39:58.541 2009  to  Fri Apr 17 05:39:58.541 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    6.76   14.47   10.50   39.34   100.0 %         16         16                      
                                                                       6.76   14.47   10.50   39.34
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    1.23    0.37    0.05    9.60   100.0 %         59         59                      
                                                                       1.23    0.37    0.05    9.60
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.85    5.25    2.40   34.47   100.0 %         30         30                      
                                                                       5.85    5.25    2.40   34.47
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.19    0.22    0.05    0.40   100.0 %          4          4                      
                                                                       0.19    0.22    0.05    0.40
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    6.76   14.58   10.61   39.45   100.0 %         16         16                      
                                                                       6.76   14.58   10.61   39.45
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.31    4.70    0.19   27.96   100.0 %         16         16                      
                                                                       6.31    4.70    0.19   27.96
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    9.87    8.58    2.18   47.27   100.0 %         99         99                      
                                                                       9.87    8.58    2.18   47.27
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.43    2.38    2.18    3.15   100.0 %          5          5                      
                                                                       0.43    2.38    2.18    3.15
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.02    0.09    0.07    0.22   100.0 %         65         65                      
                                                                       0.02    0.09    0.07    0.22
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    4.30   12.36    7.97   16.56   100.0 %          3          3                      
                                                                       4.30   12.36    7.97   16.56
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    5.96   16.32    9.31   23.34   100.0 %          4          4                      
                                                                       5.96   16.32    9.31   23.34
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.85    5.15    2.29   34.36   100.0 %         30         30                      
                                                                       5.85    5.15    2.29   34.36
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.05    0.05    0.11   100.0 %         41         41                      
                                                                       0.01    0.05    0.05    0.11
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    7.31    7.31    7.31   100.0 %          1          1                      
                                                                       0.00    7.31    7.31    7.31
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         16         16                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.22    9.36    7.30   11.67   100.0 %         16         16                      
                                                                       1.22    9.36    7.30   11.67
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    3.95    5.38    2.39   22.32   100.0 %         54         54                      
                                                                       3.95    5.38    2.39   22.32
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.05    0.05    0.11   100.0 %         41         41                      
                                                                       0.01    0.05    0.05    0.11
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.05    0.06
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.10    0.08    0.05    0.44   100.0 %         16         16                      
                                                                       0.10    0.08    0.05    0.44
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    5.75    5.06    2.81   28.03   100.0 %         27         27                      
                                                                       5.75    5.06    2.81   28.03
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.06

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest
      Nothing to report
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 16 18:21:04.596 2009  to  Thu Apr 16 18:22:11.595 2009   ( 67.00) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   2  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 16 18:21:59.733 2009  to  Thu Apr 16 18:22:11.307 2009   ( 11.57) secs
                     couldn''t find a star in any GS location.

   3  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu Apr 16 18:22:48.549 2009  to  Thu Apr 16 18:22:48.549 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

   4  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Thu Apr 16 18:22:51.000 2009  to  Thu Apr 16 18:22:51.000 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete

   5  FAILED    IIF        command.preset.(ACTIVE)                                       Thu Apr 16 18:24:17.202 2009  to  Thu Apr 16 18:25:43.456 2009   ( 86.25) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   6  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Thu Apr 16 18:25:31.643 2009  to  Thu Apr 16 18:25:43.270 2009   ( 11.63) secs
                     couldn''t find a star in any GS location.

   7  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 16 18:30:42.243 2009  to  Thu Apr 16 18:30:42.381 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   8  SEQERROR  PCS        telescope.command.stopTracking                                Thu Apr 16 18:30:42.521 2009  to  Thu Apr 16 18:30:42.521 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 16 18:30:43.450 2009  to  Thu Apr 16 18:30:43.450 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Apr 16 18:30:43.459 2009  to  Thu Apr 16 18:30:43.459 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  11  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Apr 16 18:30:44.471 2009  to  Thu Apr 16 18:30:44.471 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  12  FAILED    IIF        command.preset.(TRACK)                                        Thu Apr 16 18:33:11.342 2009  to  Thu Apr 16 18:33:13.256 2009   (  1.91) secs
                     IIF Preset command started for both LBC mode TRACK from IIF
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly:LOW EL = -1.854979e-02 rad. Too low.
                     IIF Preset command failed for both LBC mode TRACK from IIF

  13  FAILED    PCS        telescope.command.startTracking                               Thu Apr 16 18:33:11.924 2009  to  Thu Apr 16 18:33:12.989 2009   (  1.07) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR: Can''t slewToTrack becausetracking polynomials are being recv''d but aren''t usable: BAD Poly:LOW EL = -1.854979e-02 rad. Too low.

  14  FAILED    PMC        VxInterface.close                                             Thu Apr 16 18:33:15.100 2009  to  Thu Apr 16 18:33:15.100 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 18:33:15.048 2009  to  Thu Apr 16 18:33:15.048 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  16  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Thu Apr 16 18:35:22.705 2009  to  Thu Apr 16 18:35:22.705 2009   (  0.00) secs
                    

  17  FAILED    PMC        actuator.forceMonitor1.panic                                  Thu Apr 16 18:35:58.005 2009  to  Thu Apr 16 18:35:58.005 2009   (  0.00) secs
                     left PMC Actuator 316 force monitor 1 PANIC! -282.0 lbs, limit is -114.2

  18  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 16 18:40:34.011 2009  to  Thu Apr 16 18:40:34.011 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  19  FAILED    PMC        thermal.badReceive                                            Thu Apr 16 18:40:34.117 2009  to  Thu Apr 16 18:40:34.117 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  20  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 16 18:40:34.064 2009  to  Thu Apr 16 18:40:34.064 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  21  FAILED    PMC        VxInterface.packetReadError                                   Thu Apr 16 19:25:38.939 2009  to  Thu Apr 16 19:25:38.939 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  22  FAILED    PMC        VxInterface.selectTimeout                                     Thu Apr 16 19:25:38.885 2009  to  Thu Apr 16 19:25:38.885 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  23  FAILED    PMC        thermal.badReceive                                            Thu Apr 16 19:25:38.991 2009  to  Thu Apr 16 19:25:38.991 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  24  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 19:25:47.217 2009  to  Thu Apr 16 19:25:47.217 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  25  FAILED    PMC        VxInterface.close                                             Thu Apr 16 19:25:47.269 2009  to  Thu Apr 16 19:25:47.269 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  26  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Apr 16 19:34:57.925 2009  to  Thu Apr 16 19:34:57.925 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  27  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Apr 16 19:34:57.926 2009  to  Thu Apr 16 19:34:57.926 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  28  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Apr 16 22:55:18.353 2009  to  Thu Apr 16 22:55:18.353 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

  29  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Apr 16 23:14:37.227 2009  to  Thu Apr 16 23:14:37.227 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  30  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:23:52.090 2009  to  Thu Apr 16 23:23:52.090 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:23:52.038 2009  to  Thu Apr 16 23:23:52.038 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:27:21.458 2009  to  Thu Apr 16 23:27:21.458 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:27:21.405 2009  to  Thu Apr 16 23:27:21.405 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:30:08.184 2009  to  Thu Apr 16 23:30:08.184 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  35  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:30:08.236 2009  to  Thu Apr 16 23:30:08.236 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:33:17.257 2009  to  Thu Apr 16 23:33:17.257 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:33:17.310 2009  to  Thu Apr 16 23:33:17.310 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Thu Apr 16 23:42:28.668 2009  to  Thu Apr 16 23:42:28.668 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Thu Apr 16 23:42:28.720 2009  to  Thu Apr 16 23:42:28.720 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 00:40:02.313 2009  to  Fri Apr 17 00:40:02.313 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 00:40:02.340 2009  to  Fri Apr 17 00:40:02.340 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  42  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:16.353 2009  to  Fri Apr 17 00:41:16.427 2009   (  0.07) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  43  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:17.492 2009  to  Fri Apr 17 00:41:17.545 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  44  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:18.612 2009  to  Fri Apr 17 00:41:18.665 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  45  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:18.732 2009  to  Fri Apr 17 00:41:18.785 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  46  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:19.852 2009  to  Fri Apr 17 00:41:19.904 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  47  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:20.972 2009  to  Fri Apr 17 00:41:21.025 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  48  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:21.092 2009  to  Fri Apr 17 00:41:21.145 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  49  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:22.274 2009  to  Fri Apr 17 00:41:22.326 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  50  FAILED    IIF        command.authorize                                             Fri Apr 17 00:41:23.412 2009  to  Fri Apr 17 00:41:23.464 2009   (  0.05) secs
                     IIF Authorize command started for both LBC at prime focus (IIF both side)
                     IIF Authorize command failed for both LBC at prime focus (IIF both side)

  51  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.379 2009  to  Fri Apr 17 00:45:07.379 2009   (  0.00) secs
                    

  52  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.381 2009  to  Fri Apr 17 00:45:07.381 2009   (  0.00) secs
                    

  53  SXDXBOTH  MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 00:45:07.383 2009  to  Fri Apr 17 00:45:07.383 2009   (  0.00) secs
                    

  54  FAILED    PMC        VxInterface.lengthError                                       Fri Apr 17 00:58:02.407 2009  to  Fri Apr 17 00:58:02.407 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Fri Apr 17 00:58:02.459 2009  to  Fri Apr 17 00:58:02.459 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  56  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr 17 01:09:03.108 2009  to  Fri Apr 17 01:12:00.476 2009   (177.37) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  57  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 17 01:11:48.524 2009  to  Fri Apr 17 01:12:00.294 2009   ( 11.77) secs
                     couldn''t find a star in any GS location.

  58  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr 17 02:40:24.474 2009  to  Fri Apr 17 02:41:14.880 2009   ( 50.41) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  59  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Apr 17 02:41:02.852 2009  to  Fri Apr 17 02:41:14.698 2009   ( 11.85) secs
                     couldn''t find a star in any GS location.

  60  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr 17 02:45:21.383 2009  to  Fri Apr 17 02:46:55.435 2009   ( 94.05) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet minimum counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 40
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time but continuing to close guide loop as star was detected and met minimum requirements.
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  61  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr 17 02:46:54.930 2009  to  Fri Apr 17 02:46:54.930 2009   (  0.00) secs
                     guiding was not stable within 6 cycles

  62  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 02:54:44.958 2009  to  Fri Apr 17 02:54:46.626 2009   (  1.67) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  63  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 02:54:45.637 2009  to  Fri Apr 17 02:54:46.455 2009   (  0.82) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

  64  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 02:56:10.760 2009  to  Fri Apr 17 02:56:12.141 2009   (  1.38) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  65  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 02:56:11.405 2009  to  Fri Apr 17 02:56:11.971 2009   (  0.57) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

  66  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Fri Apr 17 02:56:35.614 2009  to  Fri Apr 17 02:56:35.614 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 1.010072e+00 seconds in the past!

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 02:56:35.617 2009  to  Fri Apr 17 02:56:35.617 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:23.195 2009  to  Fri Apr 17 03:03:23.195 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:23.202 2009  to  Fri Apr 17 03:03:23.202 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr 17 03:03:23.299 2009  to  Fri Apr 17 03:03:23.299 2009   (  0.00) secs
                     drive cabinet has turned on.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.319 2009  to  Fri Apr 17 03:03:24.319 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  74  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.320 2009  to  Fri Apr 17 03:03:24.320 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  75  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.321 2009  to  Fri Apr 17 03:03:24.321 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  76  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  77  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  78  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr 17 03:03:24.322 2009  to  Fri Apr 17 03:03:24.322 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  79  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:51.012 2009  to  Fri Apr 17 03:03:51.012 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  80  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr 17 03:03:51.017 2009  to  Fri Apr 17 03:03:51.017 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  81  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Apr 17 03:03:51.976 2009  to  Fri Apr 17 03:03:51.976 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  82  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Fri Apr 17 03:03:54.531 2009  to  Fri Apr 17 03:03:54.531 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 4.540564e+00 seconds in the past!

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.539 2009  to  Fri Apr 17 03:03:54.539 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468534849e+09 but t0 of the AZ target polynomial is 4.746679463991000e+09. Difference= 4.543848991394043e+00 seq=676573

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.539 2009  to  Fri Apr 17 03:03:54.539 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468535529e+09 but t0 of the EL target polynomial is 4.746679463991000e+09. Difference= 4.544528961181641e+00 seq=676573

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr 17 03:03:54.541 2009  to  Fri Apr 17 03:03:54.541 2009   (  0.00) secs
                     MJDsec from DSP is 4.746679468486069e+09 but t0 of the LFBG target polynomial is 4.746679463941000e+09. Difference= 4.545068740844727e+00 seq=231665

  86  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Apr 17 03:04:41.806 2009  to  Fri Apr 17 03:04:43.242 2009   (  1.44) secs
                     IIF Preset command started for left IRTC mode ACQUIRE from IIF
                     IIF Preset alert for left IRTC mode ACQUIRE: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for left IRTC mode ACQUIRE from IIF

  87  FAILED    PCS        telescope.command.startTracking                               Fri Apr 17 03:04:42.518 2009  to  Fri Apr 17 03:04:43.080 2009   (  0.56) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

  88  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Fri Apr 17 03:05:13.629 2009  to  Fri Apr 17 03:05:13.629 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  89  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr 17 03:05:15.361 2009  to  Fri Apr 17 03:05:15.361 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  90  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr 17 05:39:58.489 2009  to  Fri Apr 17 05:39:58.489 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  91  FAILED    PMC        thermal.badReceive                                            Fri Apr 17 05:39:58.593 2009  to  Fri Apr 17 05:39:58.593 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  92  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr 17 05:39:58.541 2009  to  Fri Apr 17 05:39:58.541 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

**********************************************************
    Reporting period ending:   Fri Apr 17 06:17:59.410 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback