    TCS Software Performance Report
 
    Observing Night:   Apr 7 2009 to Apr 8 2009
 
    Reporting period beginning:   Tue Apr  7 18:13:03.008 2009
    Reporting period ending:      Wed Apr  8 06:27:59.775 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   13.04    6.94    0.49   37.89    40.0 %         10          4          6           
                                                                      18.57   10.04    0.53   37.89

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:00.490 2009  to  Tue Apr  7 19:21:02.382 2009   (  1.89) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:00.496 2009  to  Tue Apr  7 19:21:01.168 2009   (  0.67) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:12.550 2009  to  Tue Apr  7 19:21:36.358 2009   ( 23.81) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

   4  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:12.553 2009  to  Tue Apr  7 19:21:13.038 2009   (  0.49) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for right LBC at prime focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 21:29:26.758 2009  to  Tue Apr  7 21:29:28.525 2009   (  1.77) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LBC at prime focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 21:29:26.764 2009  to  Tue Apr  7 21:29:27.334 2009   (  0.57) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   29.11   53.63   33.04   74.21     0.0 %          2                     2           
                                                                                                   
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   18.91   16.23    2.07   55.15   100.0 %          7          7                      
                                                                      18.91   16.23    2.07   55.15
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   56.16   70.31   30.60  110.02     0.0 %          2                     2           
                                                                                                   
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   23.16   17.66    2.07   67.18   100.0 %          7          7                      
                                                                      23.16   17.66    2.07   67.18
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   82.22   93.43   24.05  184.24   100.0 %          3          3                      
                                                                      82.22   93.43   24.05  184.24

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Apr  7 23:00:42.283 2009  to  Tue Apr  7 23:01:56.495 2009   ( 74.21) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   2  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Apr  7 23:02:23.092 2009  to  Tue Apr  7 23:02:56.131 2009   ( 33.04) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   3  FAILED    IIF        command.preset.(GUIDE)                                        Wed Apr  8 00:00:42.465 2009  to  Wed Apr  8 00:02:32.482 2009   (110.02) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   4  FAILED    IIF        command.preset.(GUIDE)                                        Wed Apr  8 00:03:40.568 2009  to  Wed Apr  8 00:04:11.164 2009   ( 30.60) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3638                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7276                      
                                                                                                   

ECS Single Event Activity                                          
      Nothing to report

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       5
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       6

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    0.04    0.07    0.05    0.13     0.0 %          4                     4           
                                                                                                   
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getPositionAGW . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    0.00    6.29    6.29    6.29   100.0 %          1          1                      
                                                                       0.00    6.29    6.29    6.29
     command.setGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    3.95   19.54   16.25   25.26   100.0 %          4          4                      
                                                                       3.95   19.54   16.25   25.26
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    3.08   10.32    8.10   16.93   100.0 %          7          7                      
                                                                       3.08   10.32    8.10   16.93
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    0.01    4.33    4.33    4.34   100.0 %          4          4                      
                                                                       0.01    4.33    4.33    4.34
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.00    0.18    0.18    0.18   100.0 %          4          4                      
                                                                       0.00    0.18    0.18    0.18

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest

   1  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:53:30.252 2009  to  Tue Apr  7 20:53:30.252 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   2  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:53:30.890 2009  to  Tue Apr  7 20:53:30.890 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   3  STARTUP   GCS        startup                                                       Tue Apr  7 20:55:04.006 2009  to  Tue Apr  7 20:55:04.006 2009   (  0.00) secs
                     left GCS subsystem started

   4  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:58:20.957 2009  to  Tue Apr  7 20:58:20.957 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   5  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:58:22.642 2009  to  Tue Apr  7 20:58:22.642 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   6  STARTUP   GCS        startup                                                       Tue Apr  7 20:58:30.786 2009  to  Tue Apr  7 20:58:30.786 2009   (  0.00) secs
                     left GCS subsystem started

   7  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 21:06:11.642 2009  to  Tue Apr  7 21:06:11.642 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   8  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 21:06:12.543 2009  to  Tue Apr  7 21:06:12.543 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   9  STARTUP   GCS        startup                                                       Tue Apr  7 21:07:08.730 2009  to  Tue Apr  7 21:07:08.730 2009   (  0.00) secs
                     left GCS subsystem started

  10  STARTUP   GCS        startup                                                       Tue Apr  7 21:15:46.624 2009  to  Tue Apr  7 21:15:46.624 2009   (  0.00) secs
                     left GCS subsystem started

  11  STARTUP   GCS        startup                                                       Tue Apr  7 21:22:29.636 2009  to  Tue Apr  7 21:22:29.636 2009   (  0.00) secs
                     left GCS subsystem started

  12  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Apr  7 23:01:56.270 2009  to  Tue Apr  7 23:01:56.323 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

  13  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Apr  7 23:02:55.831 2009  to  Tue Apr  7 23:02:55.961 2009   (  0.13) secs
                     full CCD readout is fully saturated. Processing impossible.

  14  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Apr  8 00:02:32.256 2009  to  Wed Apr  8 00:02:32.308 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

  15  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Apr  8 00:04:10.933 2009  to  Wed Apr  8 00:04:10.987 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .     283                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           689
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .     105                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .     104                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .     488                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .     337                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .     151                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .     429                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .      27                      
 *** MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 85           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      51                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .     108                      
 *** MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                 27           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .      27                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     341                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .     130                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                           149
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            69
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     249                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            70
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      52                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                208           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      52                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .      24                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .      23                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .      23                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .      23                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .      23                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      68                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     105                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      69                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      68                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       7                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
 *** MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                 33           
     MCSPU.Tracker.newOffset. . . . . . . . . . . . . . . . . . . .      33                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      25                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Main.termination . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.ampsOnTimeOut. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             6
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      10                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.torqueLimit. . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             3
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .      70                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      72                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .       7                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .      63                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     157                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      14                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .      54                      
     MCSPU.RTracker.trackLimitWarning . . . . . . . . . . . . . . .      14                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      24                      
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeFailSet2. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                  6           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:16:09.046 2009  to  Tue Apr  7 18:16:09.046 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:16:09.050 2009  to  Tue Apr  7 18:16:09.050 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:16:09.141 2009  to  Tue Apr  7 18:16:09.141 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.148 2009  to  Tue Apr  7 18:16:10.148 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.149 2009  to  Tue Apr  7 18:16:10.149 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.149 2009  to  Tue Apr  7 18:16:10.149 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.150 2009  to  Tue Apr  7 18:16:10.150 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.152 2009  to  Tue Apr  7 18:16:10.152 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:19:46.167 2009  to  Tue Apr  7 18:19:46.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:19:46.171 2009  to  Tue Apr  7 18:19:46.171 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  14  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:19:46.275 2009  to  Tue Apr  7 18:19:46.275 2009   (  0.00) secs
                     drive cabinet has turned on.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.301 2009  to  Tue Apr  7 18:19:47.301 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.303 2009  to  Tue Apr  7 18:19:47.303 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.304 2009  to  Tue Apr  7 18:19:47.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.304 2009  to  Tue Apr  7 18:19:47.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.305 2009  to  Tue Apr  7 18:19:47.305 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:44:23.192 2009  to  Tue Apr  7 18:44:23.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:44:23.196 2009  to  Tue Apr  7 18:44:23.196 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:44:23.289 2009  to  Tue Apr  7 18:44:23.289 2009   (  0.00) secs
                     drive cabinet has turned on.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.301 2009  to  Tue Apr  7 18:44:24.301 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.303 2009  to  Tue Apr  7 18:44:24.303 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.304 2009  to  Tue Apr  7 18:44:24.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.304 2009  to  Tue Apr  7 18:44:24.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.305 2009  to  Tue Apr  7 18:44:24.305 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 18:47:44.511 2009  to  Tue Apr  7 18:47:44.511 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:49:49.341 2009  to  Tue Apr  7 18:49:49.341 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:50:04.579 2009  to  Tue Apr  7 18:50:04.579 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872238567198e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745872238567198e+09 seq=0

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:51:26.613 2009  to  Tue Apr  7 18:51:26.613 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:51:32.555 2009  to  Tue Apr  7 18:51:32.555 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872326543407e+09 but t0 of the EL target polynomial is 4.745872319535654e+09. Difference= 7.007753372192383e+00 seq=1554

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:53:29.321 2009  to  Tue Apr  7 18:53:29.321 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:53:39.007 2009  to  Tue Apr  7 18:53:39.007 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872452994713e+09 but t0 of the EL target polynomial is 4.745872442282442e+09. Difference= 1.071227073669434e+01 seq=2222

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:55:30.022 2009  to  Tue Apr  7 18:55:30.022 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:55:38.628 2009  to  Tue Apr  7 18:55:38.628 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872572615923e+09 but t0 of the AZ target polynomial is 4.745872222339904e+09. Difference= 3.502760190963745e+02 seq=50029

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:55:47.199 2009  to  Tue Apr  7 18:55:47.199 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:55:55.396 2009  to  Tue Apr  7 18:55:55.396 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872589384363e+09 but t0 of the AZ target polynomial is 4.745872580166443e+09. Difference= 9.217920303344727e+00 seq=146

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:59:09.897 2009  to  Tue Apr  7 18:59:09.897 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:59:09.901 2009  to  Tue Apr  7 18:59:09.901 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:59:09.993 2009  to  Tue Apr  7 18:59:09.993 2009   (  0.00) secs
                     drive cabinet has turned on.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:59:11.006 2009  to  Tue Apr  7 18:59:11.006 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:04:50.465 2009  to  Tue Apr  7 19:04:50.465 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:04:50.470 2009  to  Tue Apr  7 19:04:50.470 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:04:50.573 2009  to  Tue Apr  7 19:04:50.573 2009   (  0.00) secs
                     drive cabinet has turned on.

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:05:04.136 2009  to  Tue Apr  7 19:05:04.136 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  53  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue Apr  7 19:05:10.006 2009  to  Tue Apr  7 19:05:10.006 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:05:15.068 2009  to  Tue Apr  7 19:05:15.068 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873149055085e+09 but t0 of the AZ target polynomial is 4.745873137102951e+09. Difference= 1.195213413238525e+01 seq=10449

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:05:45.635 2009  to  Tue Apr  7 19:05:45.635 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:05:50.723 2009  to  Tue Apr  7 19:05:50.723 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873184710453e+09 but t0 of the AZ target polynomial is 4.745873178607600e+09. Difference= 6.102852821350098e+00 seq=568

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:08:23.375 2009  to  Tue Apr  7 19:08:23.375 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:08:23.379 2009  to  Tue Apr  7 19:08:23.379 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:08:23.472 2009  to  Tue Apr  7 19:08:23.472 2009   (  0.00) secs
                     drive cabinet has turned on.

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:15.668 2009  to  Tue Apr  7 19:09:15.668 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:15.673 2009  to  Tue Apr  7 19:09:15.673 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  62  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:09:15.775 2009  to  Tue Apr  7 19:09:15.775 2009   (  0.00) secs
                     drive cabinet has turned on.

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:53.297 2009  to  Tue Apr  7 19:09:53.297 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:10:01.121 2009  to  Tue Apr  7 19:10:01.121 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873435107819e+09 but t0 of the AZ target polynomial is 4.745873426264675e+09. Difference= 8.843143463134766e+00 seq=4590

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:14:14.293 2009  to  Tue Apr  7 19:14:14.293 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:14:22.234 2009  to  Tue Apr  7 19:14:22.234 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873696220369e+09 but t0 of the AZ target polynomial is 4.745873687274321e+09. Difference= 8.946048736572266e+00 seq=4840

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:15:20.589 2009  to  Tue Apr  7 19:15:20.589 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:15:27.090 2009  to  Tue Apr  7 19:15:27.090 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873761076637e+09 but t0 of the AZ target polynomial is 4.745873753524364e+09. Difference= 7.552272796630859e+00 seq=1101

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:17:22.916 2009  to  Tue Apr  7 19:17:22.916 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:17:23.022 2009  to  Tue Apr  7 19:17:23.022 2009   (  0.00) secs
                     drive cabinet has turned on.

  71  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:21:46.703 2009  to  Tue Apr  7 19:21:46.703 2009   (  0.00) secs
                     drive cabinet has turned on.

  72  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:24:04.993 2009  to  Tue Apr  7 19:24:04.993 2009   (  0.00) secs
                     MJDsec from DSP is 4.745874278978759e+09 but t0 of the AZ target polynomial is 4.745874268794850e+09. Difference= 1.018390846252441e+01 seq=9703

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:24:54.088 2009  to  Tue Apr  7 19:24:54.088 2009   (  0.00) secs
                     MJDsec from DSP is 4.745874328073582e+09 but t0 of the AZ target polynomial is 4.745874321211411e+09. Difference= 6.862170219421387e+00 seq=812

  74  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:27:48.658 2009  to  Tue Apr  7 19:27:48.658 2009   (  0.00) secs
                     drive cabinet has turned on.

  75  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:30:42.991 2009  to  Tue Apr  7 19:30:42.991 2009   (  0.00) secs
                     drive cabinet has turned on.

  76  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:33:02.247 2009  to  Tue Apr  7 19:33:02.247 2009   (  0.00) secs
                     drive cabinet has turned on.

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:36:39.927 2009  to  Tue Apr  7 19:36:39.927 2009   (  0.00) secs
                     MJDsec from DSP is 4.745875033912567e+09 but t0 of the AZ target polynomial is 4.745875024284292e+09. Difference= 9.628274917602539e+00 seq=13291

  78  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:47:52.628 2009  to  Tue Apr  7 19:47:52.628 2009   (  0.00) secs
                     drive cabinet has turned on.

  79  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:52:47.177 2009  to  Tue Apr  7 19:52:47.177 2009   (  0.00) secs
                     drive cabinet has turned on.

  80  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:55:55.711 2009  to  Tue Apr  7 19:55:55.711 2009   (  0.00) secs
                     drive cabinet has turned on.

  81  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:03:39.632 2009  to  Tue Apr  7 20:03:39.632 2009   (  0.00) secs
                     drive cabinet has turned on.

  82  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:06:20.918 2009  to  Tue Apr  7 20:06:20.918 2009   (  0.00) secs
                     drive cabinet has turned on.

  83  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue Apr  7 20:06:35.164 2009  to  Tue Apr  7 20:06:35.164 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:08:20.493 2009  to  Tue Apr  7 20:08:20.493 2009   (  0.00) secs
                     MJDsec from DSP is 4.745876934474568e+09 but t0 of the AZ target polynomial is 4.745876925933081e+09. Difference= 8.541487693786621e+00 seq=36197

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:09:39.986 2009  to  Tue Apr  7 20:09:39.986 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877013967783e+09 but t0 of the AZ target polynomial is 4.745877004496625e+09. Difference= 9.471158027648926e+00 seq=1345

  86  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:10:05.779 2009  to  Tue Apr  7 20:10:05.779 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877039761190e+09 but t0 of the AZ target polynomial is 4.745877033388358e+09. Difference= 6.372832298278809e+00 seq=373

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:10:35.588 2009  to  Tue Apr  7 20:10:35.588 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877069569585e+09 but t0 of the AZ target polynomial is 4.745877059453619e+09. Difference= 1.011596584320068e+01 seq=379

  88  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:17:07.414 2009  to  Tue Apr  7 20:17:07.414 2009   (  0.00) secs
                     drive cabinet has turned on.

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:19:24.550 2009  to  Tue Apr  7 20:19:24.550 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877598530915e+09 but t0 of the AZ target polynomial is 4.745877590674951e+09. Difference= 7.855964660644531e+00 seq=9978

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:20:11.255 2009  to  Tue Apr  7 20:20:11.255 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877645236246e+09 but t0 of the AZ target polynomial is 4.745877636844805e+09. Difference= 8.391441345214844e+00 seq=736

  91  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:25:58.235 2009  to  Tue Apr  7 20:25:58.235 2009   (  0.00) secs
                     drive cabinet has turned on.

  92  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:28:08.322 2009  to  Tue Apr  7 20:28:08.322 2009   (  0.00) secs
                     drive cabinet has turned on.

  93  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:30:58.731 2009  to  Tue Apr  7 20:30:58.731 2009   (  0.00) secs
                     drive cabinet has turned on.

  94  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:32:50.764 2009  to  Tue Apr  7 20:32:50.764 2009   (  0.00) secs
                     drive cabinet has turned on.

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:33:48.561 2009  to  Tue Apr  7 20:33:48.561 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878462540753e+09 but t0 of the AZ target polynomial is 4.745878452730825e+09. Difference= 9.809927940368652e+00 seq=15407

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:34:20.110 2009  to  Tue Apr  7 20:34:20.110 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878494089639e+09 but t0 of the AZ target polynomial is 4.745878488193910e+09. Difference= 5.895729064941406e+00 seq=493

  97  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:34:52.675 2009  to  Tue Apr  7 20:34:52.675 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878526654520e+09 but t0 of the AZ target polynomial is 4.745878515563083e+09. Difference= 1.109143733978271e+01 seq=413

  98  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:35:19.917 2009  to  Tue Apr  7 20:35:19.917 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878553896922e+09 but t0 of the AZ target polynomial is 4.745878546585891e+09. Difference= 7.311031341552734e+00 seq=384

  99  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:36:58.978 2009  to  Tue Apr  7 20:36:58.978 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878652957567e+09 but t0 of the AZ target polynomial is 4.745878624056015e+09. Difference= 2.890155220031738e+01 seq=1347

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:37:37.058 2009  to  Tue Apr  7 20:37:37.058 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878691037227e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745878691037227e+09 seq=0

 101  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:44:43.524 2009  to  Tue Apr  7 20:44:43.524 2009   (  0.00) secs
                     drive cabinet has turned on.

 102  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 20:44:57.712 2009  to  Tue Apr  7 20:44:57.712 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 103  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Tue Apr  7 20:48:25.931 2009  to  Tue Apr  7 20:48:25.931 2009   (  0.00) secs
                     Main program is terminating.

 104  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:49:04.039 2009  to  Tue Apr  7 20:49:04.039 2009   (  0.00) secs
                     drive cabinet has turned on.

 105  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Tue Apr  7 20:49:23.473 2009  to  Tue Apr  7 20:49:23.473 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 106  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:54:03.743 2009  to  Tue Apr  7 20:54:03.743 2009   (  0.00) secs
                     drive cabinet has turned on.

 107  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 20:56:02.994 2009  to  Tue Apr  7 20:56:02.994 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 108  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Wed Apr  8 02:38:33.023 2009  to  Wed Apr  8 02:38:33.023 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 109  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Wed Apr  8 02:38:36.942 2009  to  Wed Apr  8 02:38:36.942 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 110  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Wed Apr  8 02:38:37.051 2009  to  Wed Apr  8 02:38:37.051 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 111  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Wed Apr  8 02:41:46.876 2009  to  Wed Apr  8 02:41:46.876 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 112  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Wed Apr  8 02:45:29.046 2009  to  Wed Apr  8 02:45:29.046 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

 113  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Wed Apr  8 02:45:29.046 2009  to  Wed Apr  8 02:45:29.046 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 114  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Apr  8 02:45:36.505 2009  to  Wed Apr  8 02:45:36.505 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 115  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:25:32.765 2009  to  Wed Apr  8 06:25:32.765 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly:LOWEL = -1.264986e-02 rad. Too low.

 116  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:25:35.815 2009  to  Wed Apr  8 06:25:35.815 2009   (  0.00) secs
                     EL bad poly no. 62: BAD Poly:LOWEL = -3.372927e-01 rad. Too low.

 117  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:31.348 2009  to  Wed Apr  8 06:27:31.348 2009   (  0.00) secs
                     EL bad poly no. 84: BAD Poly:LOWEL = -1.927470e-03 rad. Too low.

 118  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:34.403 2009  to  Wed Apr  8 06:27:34.403 2009   (  0.00) secs
                     EL bad poly no. 145: BAD Poly:LOWEL = -8.735369e-02 rad. Too low.

 119  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:37.399 2009  to  Wed Apr  8 06:27:37.399 2009   (  0.00) secs
                     EL bad poly no. 205: BAD Poly:LOWEL = -3.291176e-01 rad. Too low.

 120  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:41.751 2009  to  Wed Apr  8 06:27:41.751 2009   (  0.00) secs
                     EL bad poly no. 209: BAD Poly:LOWEL = -2.655672e-02 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    2.21    3.91    2.65    8.90   100.0 %          7          7                      
                                                                       2.21    3.91    2.65    8.90
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.24    3.25    3.03    3.74   100.0 %          7          7                      
                                                                       0.24    3.25    3.03    3.74
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .   10.11   29.28   22.13   36.43   100.0 %          2          2                      
                                                                      10.11   29.28   22.13   36.43

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             2

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.05    0.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.07    0.05    0.13   100.0 %          7          7                      
                                                                       0.03    0.07    0.05    0.13
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.03    0.42    0.39    0.45   100.0 %          5          5                      
                                                                       0.03    0.42    0.39    0.45
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.46    0.31    0.82   100.0 %          7          7                      
                                                                       0.20    0.46    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.03    0.05    0.00    0.11    40.0 %         10                     6           
                                                                       0.00    0.04    0.03    0.04

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Tue Apr  7 18:41:06.392 2009  to  Tue Apr  7 18:41:06.392 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

   2  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:00.565 2009  to  Tue Apr  7 19:21:00.617 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

   3  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:00.633 2009  to  Tue Apr  7 19:21:00.685 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

   4  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:12.616 2009  to  Tue Apr  7 19:21:12.667 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

   5  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:12.680 2009  to  Tue Apr  7 19:21:12.735 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

   6  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 21:29:26.825 2009  to  Tue Apr  7 21:29:26.886 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 21:29:27.004 2009  to  Tue Apr  7 21:29:27.115 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   8  STARTUP   PCS        startup                                                       Tue Apr  7 21:29:53.683 2009  to  Tue Apr  7 21:29:53.683 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

   9  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:45.481 2009  to  Tue Apr  7 22:19:45.549 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  10  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:45.680 2009  to  Tue Apr  7 22:19:45.680 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  11  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:51.458 2009  to  Tue Apr  7 22:19:51.529 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  12  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:51.636 2009  to  Tue Apr  7 22:19:51.636 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   17.67   18.23    2.06   43.14   100.0 %          7          7                      
                                                                      17.67   18.23    2.06   43.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      56                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      56                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       2                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  3           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Tue Apr  7 22:32:09.731 2009  to  Tue Apr  7 22:32:09.731 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

   2  FAILED    PMC        VxInterface.close                                             Tue Apr  7 22:32:09.784 2009  to  Tue Apr  7 22:32:09.784 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   3  FAILED    PMC        VxInterface.close                                             Wed Apr  8 00:02:05.059 2009  to  Wed Apr  8 00:02:05.059 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Wed Apr  8 00:02:05.007 2009  to  Wed Apr  8 00:02:05.007 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 00:30:51.853 2009  to  Wed Apr  8 00:30:51.853 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   6  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 00:30:51.959 2009  to  Wed Apr  8 00:30:51.959 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   7  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 00:30:51.907 2009  to  Wed Apr  8 00:30:51.907 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   8  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 02:48:57.103 2009  to  Wed Apr  8 02:48:57.103 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   9  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 02:48:57.050 2009  to  Wed Apr  8 02:48:57.050 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  10  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 02:48:57.156 2009  to  Wed Apr  8 02:48:57.156 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  11  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 03:47:01.124 2009  to  Wed Apr  8 03:47:01.124 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  12  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 03:47:01.284 2009  to  Wed Apr  8 03:47:01.284 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  13  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 03:47:01.336 2009  to  Wed Apr  8 03:47:01.336 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.07    0.33    0.27    0.42   100.0 %          7          7                      
                                                                       0.07    0.33    0.27    0.42
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.21    0.21    0.05    0.56    90.0 %         10          9          1           
                                                                       0.17    0.17    0.05    0.42
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   17.69   18.39    2.20   43.36   100.0 %          7          7                      
                                                                      17.69   18.39    2.20   43.36
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.06    0.09    0.06    0.19    75.0 %          4          3          1           
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.05    0.07    0.05    0.19   100.0 %          7          7                      
                                                                       0.05    0.07    0.05    0.19
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    2.21    4.05    2.78    9.03   100.0 %          7          7                      
                                                                       2.21    4.05    2.78    9.03
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          7          7                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.01    0.07    0.06    0.08   100.0 %          4          4                      
                                                                       0.01    0.07    0.06    0.08
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    0.24    3.41    3.16    3.87   100.0 %          7          7                      
                                                                       0.24    3.41    3.16    3.87
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.01    0.06    0.05    0.07   100.0 %          4          4                      
                                                                       0.01    0.06    0.05    0.07

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Tue Apr  7 19:21:01.539 2009  to  Tue Apr  7 19:21:02.102 2009   (  0.56) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Apr  7 19:21:01.592 2009  to  Tue Apr  7 19:21:01.777 2009   (  0.19) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:16:09.046 2009  to  Tue Apr  7 18:16:09.046 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:16:09.050 2009  to  Tue Apr  7 18:16:09.050 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:16:09.141 2009  to  Tue Apr  7 18:16:09.141 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.148 2009  to  Tue Apr  7 18:16:10.148 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.149 2009  to  Tue Apr  7 18:16:10.149 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.149 2009  to  Tue Apr  7 18:16:10.149 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.150 2009  to  Tue Apr  7 18:16:10.150 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.151 2009  to  Tue Apr  7 18:16:10.151 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:16:10.152 2009  to  Tue Apr  7 18:16:10.152 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:19:46.167 2009  to  Tue Apr  7 18:19:46.167 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:19:46.171 2009  to  Tue Apr  7 18:19:46.171 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  14  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:19:46.275 2009  to  Tue Apr  7 18:19:46.275 2009   (  0.00) secs
                     drive cabinet has turned on.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.301 2009  to  Tue Apr  7 18:19:47.301 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.302 2009  to  Tue Apr  7 18:19:47.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.303 2009  to  Tue Apr  7 18:19:47.303 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.304 2009  to  Tue Apr  7 18:19:47.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.304 2009  to  Tue Apr  7 18:19:47.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:19:47.305 2009  to  Tue Apr  7 18:19:47.305 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  STARTUP   PCS        startup                                                       Tue Apr  7 18:41:06.392 2009  to  Tue Apr  7 18:41:06.392 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:44:23.192 2009  to  Tue Apr  7 18:44:23.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:44:23.196 2009  to  Tue Apr  7 18:44:23.196 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  26  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:44:23.289 2009  to  Tue Apr  7 18:44:23.289 2009   (  0.00) secs
                     drive cabinet has turned on.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.301 2009  to  Tue Apr  7 18:44:24.301 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.302 2009  to  Tue Apr  7 18:44:24.302 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.303 2009  to  Tue Apr  7 18:44:24.303 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.304 2009  to  Tue Apr  7 18:44:24.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.304 2009  to  Tue Apr  7 18:44:24.304 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:44:24.305 2009  to  Tue Apr  7 18:44:24.305 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  35  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 18:47:44.511 2009  to  Tue Apr  7 18:47:44.511 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:49:49.341 2009  to  Tue Apr  7 18:49:49.341 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:50:04.579 2009  to  Tue Apr  7 18:50:04.579 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872238567198e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745872238567198e+09 seq=0

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:51:26.613 2009  to  Tue Apr  7 18:51:26.613 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:51:32.555 2009  to  Tue Apr  7 18:51:32.555 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872326543407e+09 but t0 of the EL target polynomial is 4.745872319535654e+09. Difference= 7.007753372192383e+00 seq=1554

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:53:29.321 2009  to  Tue Apr  7 18:53:29.321 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:53:39.007 2009  to  Tue Apr  7 18:53:39.007 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872452994713e+09 but t0 of the EL target polynomial is 4.745872442282442e+09. Difference= 1.071227073669434e+01 seq=2222

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:55:30.022 2009  to  Tue Apr  7 18:55:30.022 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:55:38.628 2009  to  Tue Apr  7 18:55:38.628 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872572615923e+09 but t0 of the AZ target polynomial is 4.745872222339904e+09. Difference= 3.502760190963745e+02 seq=50029

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:55:47.199 2009  to  Tue Apr  7 18:55:47.199 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 18:55:55.396 2009  to  Tue Apr  7 18:55:55.396 2009   (  0.00) secs
                     MJDsec from DSP is 4.745872589384363e+09 but t0 of the AZ target polynomial is 4.745872580166443e+09. Difference= 9.217920303344727e+00 seq=146

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:59:09.897 2009  to  Tue Apr  7 18:59:09.897 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 18:59:09.901 2009  to  Tue Apr  7 18:59:09.901 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  48  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 18:59:09.993 2009  to  Tue Apr  7 18:59:09.993 2009   (  0.00) secs
                     drive cabinet has turned on.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Apr  7 18:59:11.006 2009  to  Tue Apr  7 18:59:11.006 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:04:50.465 2009  to  Tue Apr  7 19:04:50.465 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:04:50.470 2009  to  Tue Apr  7 19:04:50.470 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:04:50.573 2009  to  Tue Apr  7 19:04:50.573 2009   (  0.00) secs
                     drive cabinet has turned on.

  53  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:05:04.136 2009  to  Tue Apr  7 19:05:04.136 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  54  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue Apr  7 19:05:10.006 2009  to  Tue Apr  7 19:05:10.006 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:05:15.068 2009  to  Tue Apr  7 19:05:15.068 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873149055085e+09 but t0 of the AZ target polynomial is 4.745873137102951e+09. Difference= 1.195213413238525e+01 seq=10449

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:05:45.635 2009  to  Tue Apr  7 19:05:45.635 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:05:50.723 2009  to  Tue Apr  7 19:05:50.723 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873184710453e+09 but t0 of the AZ target polynomial is 4.745873178607600e+09. Difference= 6.102852821350098e+00 seq=568

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:08:23.375 2009  to  Tue Apr  7 19:08:23.375 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:08:23.379 2009  to  Tue Apr  7 19:08:23.379 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  60  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:08:23.472 2009  to  Tue Apr  7 19:08:23.472 2009   (  0.00) secs
                     drive cabinet has turned on.

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:15.668 2009  to  Tue Apr  7 19:09:15.668 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:15.673 2009  to  Tue Apr  7 19:09:15.673 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  63  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:09:15.775 2009  to  Tue Apr  7 19:09:15.775 2009   (  0.00) secs
                     drive cabinet has turned on.

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:09:53.297 2009  to  Tue Apr  7 19:09:53.297 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:10:01.121 2009  to  Tue Apr  7 19:10:01.121 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873435107819e+09 but t0 of the AZ target polynomial is 4.745873426264675e+09. Difference= 8.843143463134766e+00 seq=4590

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:14:14.293 2009  to  Tue Apr  7 19:14:14.293 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:14:22.234 2009  to  Tue Apr  7 19:14:22.234 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873696220369e+09 but t0 of the AZ target polynomial is 4.745873687274321e+09. Difference= 8.946048736572266e+00 seq=4840

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:15:20.589 2009  to  Tue Apr  7 19:15:20.589 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:15:27.090 2009  to  Tue Apr  7 19:15:27.090 2009   (  0.00) secs
                     MJDsec from DSP is 4.745873761076637e+09 but t0 of the AZ target polynomial is 4.745873753524364e+09. Difference= 7.552272796630859e+00 seq=1101

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Apr  7 19:17:22.916 2009  to  Tue Apr  7 19:17:22.916 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  71  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:17:23.022 2009  to  Tue Apr  7 19:17:23.022 2009   (  0.00) secs
                     drive cabinet has turned on.

  72  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:00.490 2009  to  Tue Apr  7 19:21:02.382 2009   (  1.89) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

  73  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:00.496 2009  to  Tue Apr  7 19:21:01.168 2009   (  0.67) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for right LBC at prime focus

  74  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:00.565 2009  to  Tue Apr  7 19:21:00.617 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

  75  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:00.633 2009  to  Tue Apr  7 19:21:00.685 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

  76  FAILED    PSF        command.setNewInstrument                                      Tue Apr  7 19:21:01.539 2009  to  Tue Apr  7 19:21:02.102 2009   (  0.56) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

  77  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Tue Apr  7 19:21:01.592 2009  to  Tue Apr  7 19:21:01.777 2009   (  0.19) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  78  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:12.550 2009  to  Tue Apr  7 19:21:36.358 2009   ( 23.81) secs
                     IIF TCS authorize alert for left IRTC at bentGregorianFront focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for left IRTC at bentGregorianFront focus

  79  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 19:21:12.553 2009  to  Tue Apr  7 19:21:13.038 2009   (  0.49) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                     IIF TCS authorize command failed for right LBC at prime focus

  80  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:12.616 2009  to  Tue Apr  7 19:21:12.667 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

  81  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 19:21:12.680 2009  to  Tue Apr  7 19:21:12.735 2009   (  0.05) secs
                     PCS will stop tracking target
                     PCS stop tracking command failed because ERROR: MCSPU is not connected.

  82  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:21:46.703 2009  to  Tue Apr  7 19:21:46.703 2009   (  0.00) secs
                     drive cabinet has turned on.

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:24:04.993 2009  to  Tue Apr  7 19:24:04.993 2009   (  0.00) secs
                     MJDsec from DSP is 4.745874278978759e+09 but t0 of the AZ target polynomial is 4.745874268794850e+09. Difference= 1.018390846252441e+01 seq=9703

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:24:54.088 2009  to  Tue Apr  7 19:24:54.088 2009   (  0.00) secs
                     MJDsec from DSP is 4.745874328073582e+09 but t0 of the AZ target polynomial is 4.745874321211411e+09. Difference= 6.862170219421387e+00 seq=812

  85  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:27:48.658 2009  to  Tue Apr  7 19:27:48.658 2009   (  0.00) secs
                     drive cabinet has turned on.

  86  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:30:42.991 2009  to  Tue Apr  7 19:30:42.991 2009   (  0.00) secs
                     drive cabinet has turned on.

  87  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:33:02.247 2009  to  Tue Apr  7 19:33:02.247 2009   (  0.00) secs
                     drive cabinet has turned on.

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 19:36:39.927 2009  to  Tue Apr  7 19:36:39.927 2009   (  0.00) secs
                     MJDsec from DSP is 4.745875033912567e+09 but t0 of the AZ target polynomial is 4.745875024284292e+09. Difference= 9.628274917602539e+00 seq=13291

  89  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:47:52.628 2009  to  Tue Apr  7 19:47:52.628 2009   (  0.00) secs
                     drive cabinet has turned on.

  90  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:52:47.177 2009  to  Tue Apr  7 19:52:47.177 2009   (  0.00) secs
                     drive cabinet has turned on.

  91  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 19:55:55.711 2009  to  Tue Apr  7 19:55:55.711 2009   (  0.00) secs
                     drive cabinet has turned on.

  92  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:03:39.632 2009  to  Tue Apr  7 20:03:39.632 2009   (  0.00) secs
                     drive cabinet has turned on.

  93  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:06:20.918 2009  to  Tue Apr  7 20:06:20.918 2009   (  0.00) secs
                     drive cabinet has turned on.

  94  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Tue Apr  7 20:06:35.164 2009  to  Tue Apr  7 20:06:35.164 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:08:20.493 2009  to  Tue Apr  7 20:08:20.493 2009   (  0.00) secs
                     MJDsec from DSP is 4.745876934474568e+09 but t0 of the AZ target polynomial is 4.745876925933081e+09. Difference= 8.541487693786621e+00 seq=36197

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:09:39.986 2009  to  Tue Apr  7 20:09:39.986 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877013967783e+09 but t0 of the AZ target polynomial is 4.745877004496625e+09. Difference= 9.471158027648926e+00 seq=1345

  97  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:10:05.779 2009  to  Tue Apr  7 20:10:05.779 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877039761190e+09 but t0 of the AZ target polynomial is 4.745877033388358e+09. Difference= 6.372832298278809e+00 seq=373

  98  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:10:35.588 2009  to  Tue Apr  7 20:10:35.588 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877069569585e+09 but t0 of the AZ target polynomial is 4.745877059453619e+09. Difference= 1.011596584320068e+01 seq=379

  99  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:17:07.414 2009  to  Tue Apr  7 20:17:07.414 2009   (  0.00) secs
                     drive cabinet has turned on.

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:19:24.550 2009  to  Tue Apr  7 20:19:24.550 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877598530915e+09 but t0 of the AZ target polynomial is 4.745877590674951e+09. Difference= 7.855964660644531e+00 seq=9978

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:20:11.255 2009  to  Tue Apr  7 20:20:11.255 2009   (  0.00) secs
                     MJDsec from DSP is 4.745877645236246e+09 but t0 of the AZ target polynomial is 4.745877636844805e+09. Difference= 8.391441345214844e+00 seq=736

 102  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:25:58.235 2009  to  Tue Apr  7 20:25:58.235 2009   (  0.00) secs
                     drive cabinet has turned on.

 103  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:28:08.322 2009  to  Tue Apr  7 20:28:08.322 2009   (  0.00) secs
                     drive cabinet has turned on.

 104  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:30:58.731 2009  to  Tue Apr  7 20:30:58.731 2009   (  0.00) secs
                     drive cabinet has turned on.

 105  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:32:50.764 2009  to  Tue Apr  7 20:32:50.764 2009   (  0.00) secs
                     drive cabinet has turned on.

 106  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:33:48.561 2009  to  Tue Apr  7 20:33:48.561 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878462540753e+09 but t0 of the AZ target polynomial is 4.745878452730825e+09. Difference= 9.809927940368652e+00 seq=15407

 107  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:34:20.110 2009  to  Tue Apr  7 20:34:20.110 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878494089639e+09 but t0 of the AZ target polynomial is 4.745878488193910e+09. Difference= 5.895729064941406e+00 seq=493

 108  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:34:52.675 2009  to  Tue Apr  7 20:34:52.675 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878526654520e+09 but t0 of the AZ target polynomial is 4.745878515563083e+09. Difference= 1.109143733978271e+01 seq=413

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:35:19.917 2009  to  Tue Apr  7 20:35:19.917 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878553896922e+09 but t0 of the AZ target polynomial is 4.745878546585891e+09. Difference= 7.311031341552734e+00 seq=384

 110  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:36:58.978 2009  to  Tue Apr  7 20:36:58.978 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878652957567e+09 but t0 of the AZ target polynomial is 4.745878624056015e+09. Difference= 2.890155220031738e+01 seq=1347

 111  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Tue Apr  7 20:37:37.058 2009  to  Tue Apr  7 20:37:37.058 2009   (  0.00) secs
                     MJDsec from DSP is 4.745878691037227e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745878691037227e+09 seq=0

 112  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:44:43.524 2009  to  Tue Apr  7 20:44:43.524 2009   (  0.00) secs
                     drive cabinet has turned on.

 113  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 20:44:57.712 2009  to  Tue Apr  7 20:44:57.712 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 114  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Tue Apr  7 20:48:25.931 2009  to  Tue Apr  7 20:48:25.931 2009   (  0.00) secs
                     Main program is terminating.

 115  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:49:04.039 2009  to  Tue Apr  7 20:49:04.039 2009   (  0.00) secs
                     drive cabinet has turned on.

 116  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Tue Apr  7 20:49:23.473 2009  to  Tue Apr  7 20:49:23.473 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 117  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:53:30.252 2009  to  Tue Apr  7 20:53:30.252 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 118  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:53:30.890 2009  to  Tue Apr  7 20:53:30.890 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 119  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Apr  7 20:54:03.743 2009  to  Tue Apr  7 20:54:03.743 2009   (  0.00) secs
                     drive cabinet has turned on.

 120  STARTUP   GCS        startup                                                       Tue Apr  7 20:55:04.006 2009  to  Tue Apr  7 20:55:04.006 2009   (  0.00) secs
                     left GCS subsystem started

 121  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Apr  7 20:56:02.994 2009  to  Tue Apr  7 20:56:02.994 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 122  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:58:20.957 2009  to  Tue Apr  7 20:58:20.957 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 123  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 20:58:22.642 2009  to  Tue Apr  7 20:58:22.642 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 124  STARTUP   GCS        startup                                                       Tue Apr  7 20:58:30.786 2009  to  Tue Apr  7 20:58:30.786 2009   (  0.00) secs
                     left GCS subsystem started

 125  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 21:06:11.642 2009  to  Tue Apr  7 21:06:11.642 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 126  SHUTDOWN  GCS        command.shutdown                                              Tue Apr  7 21:06:12.543 2009  to  Tue Apr  7 21:06:12.543 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 127  STARTUP   GCS        startup                                                       Tue Apr  7 21:07:08.730 2009  to  Tue Apr  7 21:07:08.730 2009   (  0.00) secs
                     left GCS subsystem started

 128  STARTUP   GCS        startup                                                       Tue Apr  7 21:15:46.624 2009  to  Tue Apr  7 21:15:46.624 2009   (  0.00) secs
                     left GCS subsystem started

 129  STARTUP   GCS        startup                                                       Tue Apr  7 21:22:29.636 2009  to  Tue Apr  7 21:22:29.636 2009   (  0.00) secs
                     left GCS subsystem started

 130  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 21:29:26.758 2009  to  Tue Apr  7 21:29:28.525 2009   (  1.77) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LBC at prime focus

 131  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Apr  7 21:29:26.764 2009  to  Tue Apr  7 21:29:27.334 2009   (  0.57) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

 132  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 21:29:26.825 2009  to  Tue Apr  7 21:29:26.886 2009   (  0.06) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 133  FAILED    PCS        telescope.command.stopTracking                                Tue Apr  7 21:29:27.004 2009  to  Tue Apr  7 21:29:27.115 2009   (  0.11) secs
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

 134  STARTUP   PCS        startup                                                       Tue Apr  7 21:29:53.683 2009  to  Tue Apr  7 21:29:53.683 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

 135  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:45.481 2009  to  Tue Apr  7 22:19:45.549 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 136  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:45.680 2009  to  Tue Apr  7 22:19:45.680 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 137  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:51.458 2009  to  Tue Apr  7 22:19:51.529 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 138  SEQERROR  PCS        telescope.command.stopTracking                                Tue Apr  7 22:19:51.636 2009  to  Tue Apr  7 22:19:51.636 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 139  FAILED    PMC        VxInterface.lengthError                                       Tue Apr  7 22:32:09.731 2009  to  Tue Apr  7 22:32:09.731 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 140  FAILED    PMC        VxInterface.close                                             Tue Apr  7 22:32:09.784 2009  to  Tue Apr  7 22:32:09.784 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 141  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Apr  7 23:00:42.283 2009  to  Tue Apr  7 23:01:56.495 2009   ( 74.21) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 142  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Apr  7 23:01:56.270 2009  to  Tue Apr  7 23:01:56.323 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

 143  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Apr  7 23:02:23.092 2009  to  Tue Apr  7 23:02:56.131 2009   ( 33.04) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 144  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Apr  7 23:02:55.831 2009  to  Tue Apr  7 23:02:55.961 2009   (  0.13) secs
                     full CCD readout is fully saturated. Processing impossible.

 145  FAILED    IIF        command.preset.(GUIDE)                                        Wed Apr  8 00:00:42.465 2009  to  Wed Apr  8 00:02:32.482 2009   (110.02) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 146  FAILED    PMC        VxInterface.close                                             Wed Apr  8 00:02:05.059 2009  to  Wed Apr  8 00:02:05.059 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 147  FAILED    PMC        VxInterface.lengthError                                       Wed Apr  8 00:02:05.007 2009  to  Wed Apr  8 00:02:05.007 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 148  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Apr  8 00:02:32.256 2009  to  Wed Apr  8 00:02:32.308 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

 149  FAILED    IIF        command.preset.(GUIDE)                                        Wed Apr  8 00:03:40.568 2009  to  Wed Apr  8 00:04:11.164 2009   ( 30.60) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

 150  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Apr  8 00:04:10.933 2009  to  Wed Apr  8 00:04:10.987 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

 151  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 00:30:51.853 2009  to  Wed Apr  8 00:30:51.853 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 152  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 00:30:51.959 2009  to  Wed Apr  8 00:30:51.959 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 153  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 00:30:51.907 2009  to  Wed Apr  8 00:30:51.907 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 154  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Wed Apr  8 02:38:33.023 2009  to  Wed Apr  8 02:38:33.023 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 155  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Wed Apr  8 02:38:36.942 2009  to  Wed Apr  8 02:38:36.942 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 156  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Wed Apr  8 02:38:37.051 2009  to  Wed Apr  8 02:38:37.051 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 157  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Wed Apr  8 02:41:46.876 2009  to  Wed Apr  8 02:41:46.876 2009   (  0.00) secs
                     The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 158  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Wed Apr  8 02:45:29.046 2009  to  Wed Apr  8 02:45:29.046 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

 159  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Wed Apr  8 02:45:29.046 2009  to  Wed Apr  8 02:45:29.046 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 160  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Apr  8 02:45:36.505 2009  to  Wed Apr  8 02:45:36.505 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 161  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 02:48:57.103 2009  to  Wed Apr  8 02:48:57.103 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 162  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 02:48:57.050 2009  to  Wed Apr  8 02:48:57.050 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 163  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 02:48:57.156 2009  to  Wed Apr  8 02:48:57.156 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 164  FAILED    PMC        VxInterface.selectTimeout                                     Wed Apr  8 03:47:01.124 2009  to  Wed Apr  8 03:47:01.124 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 165  FAILED    PMC        VxInterface.packetReadError                                   Wed Apr  8 03:47:01.284 2009  to  Wed Apr  8 03:47:01.284 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 166  FAILED    PMC        thermal.badReceive                                            Wed Apr  8 03:47:01.336 2009  to  Wed Apr  8 03:47:01.336 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 167  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:25:32.765 2009  to  Wed Apr  8 06:25:32.765 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly:LOWEL = -1.264986e-02 rad. Too low.

 168  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:25:35.815 2009  to  Wed Apr  8 06:25:35.815 2009   (  0.00) secs
                     EL bad poly no. 62: BAD Poly:LOWEL = -3.372927e-01 rad. Too low.

 169  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:31.348 2009  to  Wed Apr  8 06:27:31.348 2009   (  0.00) secs
                     EL bad poly no. 84: BAD Poly:LOWEL = -1.927470e-03 rad. Too low.

 170  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:34.403 2009  to  Wed Apr  8 06:27:34.403 2009   (  0.00) secs
                     EL bad poly no. 145: BAD Poly:LOWEL = -8.735369e-02 rad. Too low.

 171  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:37.399 2009  to  Wed Apr  8 06:27:37.399 2009   (  0.00) secs
                     EL bad poly no. 205: BAD Poly:LOWEL = -3.291176e-01 rad. Too low.

 172  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Apr  8 06:27:41.751 2009  to  Wed Apr  8 06:27:41.751 2009   (  0.00) secs
                     EL bad poly no. 209: BAD Poly:LOWEL = -2.655672e-02 rad. Too low.

**********************************************************
    Reporting period ending:   Wed Apr  8 06:27:59.775 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing