You are here: Foswiki>Software Web>TCSSWReportFile_090403 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Apr 3 2009 to Apr 4 2009
 
    Reporting period beginning:   Fri Apr  3 18:11:08.744 2009
    Reporting period ending:      Sat Apr  4 06:33:52.232 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   13.78    7.76    0.40   28.40    75.0 %          4          3          1           
                                                                      16.14    9.76    0.40   28.40

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Apr  3 22:11:12.452 2009  to  Fri Apr  3 22:11:14.194 2009   (  1.74) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.10    0.36    0.27    0.65   100.0 %         36         36                      
                                                                       0.10    0.36    0.27    0.65
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.06    0.20    0.16    0.68   100.0 %         62         62                      
                                                                       0.06    0.20    0.16    0.68
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.25    5.20    0.63   15.74    46.9 %         32         15         17           
                                                                       2.77   10.35    6.53   15.74
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.96    6.41    4.98    7.22   100.0 %          5          5                      
                                                                       0.96    6.41    4.98    7.22
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.97    5.79    4.46    6.67   100.0 %          5          5                      
                                                                       0.97    5.79    4.46    6.67
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   26.13  136.83  101.20  156.71     0.0 %          4                     4           
                                                                                                   
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   15.97   16.00    0.00   39.13   100.0 %         10         10                      
                                                                      15.86   17.78    1.05   39.13
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .    0.00  224.09  224.09  224.09     0.0 %          1                     1           
                                                                                                   
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    9.04    8.07    1.05   21.09   100.0 %          5          5                      
                                                                       9.04    8.07    1.05   21.09
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   29.84   24.89    0.00   73.28     0.0 %          5                     5           
                                                                                                   
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    2.33    2.34    0.69    3.98   100.0 %          2          2                      
                                                                       2.33    2.34    0.69    3.98
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    0.09    0.70    0.64    0.76     0.0 %          2                     2           
                                                                                                   

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr  3 21:57:33.845 2009  to  Fri Apr  3 22:01:17.938 2009   (224.09) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 443
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

   2  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 22:02:23.998 2009  to  Fri Apr  3 22:04:37.315 2009   (133.32) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 4082 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   3  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 22:06:12.146 2009  to  Fri Apr  3 22:07:53.347 2009   (101.20) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

   4  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 22:19:34.548 2009  to  Fri Apr  3 22:20:47.827 2009   ( 73.28) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

   5  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:20:49.120 2009  to  Fri Apr  3 22:20:49.792 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:23:05.668 2009  to  Fri Apr  3 22:23:06.300 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   7  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:26:14.947 2009  to  Fri Apr  3 22:26:15.583 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

   8  FAILED    IIF        command.stepFocus                                             Fri Apr  3 22:27:14.369 2009  to  Fri Apr  3 22:27:15.134 2009   (  0.76) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

   9  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:27:15.453 2009  to  Fri Apr  3 22:27:16.094 2009   (  0.64) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  10  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:29:48.735 2009  to  Fri Apr  3 22:29:49.377 2009   (  0.64) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  11  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:32:32.900 2009  to  Fri Apr  3 22:32:33.548 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  12  FAILED    IIF        command.stepFocus                                             Fri Apr  3 22:33:43.513 2009  to  Fri Apr  3 22:33:44.150 2009   (  0.64) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  13  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:33:44.701 2009  to  Fri Apr  3 22:33:45.346 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  14  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:36:18.033 2009  to  Fri Apr  3 22:36:18.658 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  15  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:39:00.217 2009  to  Fri Apr  3 22:39:00.869 2009   (  0.65) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  16  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:41:30.329 2009  to  Fri Apr  3 22:41:31.085 2009   (  0.76) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  17  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 22:52:17.863 2009  to  Fri Apr  3 22:52:22.821 2009   (  4.96) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

  18  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:52:23.987 2009  to  Fri Apr  3 22:52:24.624 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  19  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:53:15.537 2009  to  Fri Apr  3 22:53:16.201 2009   (  0.66) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  20  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:55:48.768 2009  to  Fri Apr  3 22:55:49.441 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  21  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:58:32.733 2009  to  Fri Apr  3 22:58:33.367 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

  22  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 23:19:50.520 2009  to  Fri Apr  3 23:20:03.709 2009   ( 13.19) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

  23  SEQERROR  IIF        command.preset.(TRACK)                                        Fri Apr  3 23:21:28.691 2009  to  Fri Apr  3 23:21:45.626 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

  24  SEQERROR  IIF        command.preset.elevationWait                                  Fri Apr  3 23:21:30.035 2009  to  Fri Apr  3 23:21:46.934 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

  25  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 23:21:45.626 2009  to  Fri Apr  3 23:22:18.656 2009   ( 33.03) secs
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

  26  SEQERROR  IIF        command.preset.elevationWait                                  Fri Apr  3 23:22:18.172 2009  to  Fri Apr  3 23:22:18.172 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for elevation complete for both LBC

  27  SEQERROR  IIF        command.preset.(TRACK)                                        Fri Apr  3 23:23:03.596 2009  to  Fri Apr  3 23:23:03.596 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for both LBC mode TRACK from IIF

  28  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:23:04.092 2009  to  Fri Apr  3 23:23:04.728 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 3.530000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.000000000000000e-02

  29  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:25:20.294 2009  to  Fri Apr  3 23:25:21.035 2009   (  0.74) secs
                     IIF MoveFocus command started for right LBC for 7.800000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

  30  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:27:25.103 2009  to  Fri Apr  3 23:27:25.821 2009   (  0.72) secs
                     IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

  31  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 23:37:40.713 2009  to  Fri Apr  3 23:40:17.423 2009   (156.71) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  32  FAILED    IIF        command.preset.(ACTIVE)                                       Sat Apr  4 01:07:15.555 2009  to  Sat Apr  4 01:09:51.637 2009   (156.08) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 4416 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3672                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7344                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    16                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      22                      
     instrumentCooling.badWeatherData . . . . . . . . . . . . . . .                             2
     hydraulicBearing.badWeatherData. . . . . . . . . . . . . . . .                             2
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                  1           
     hydraulicBearing.badPMCData. . . . . . . . . . . . . . . . . .                  1           

ECS Events of Interest

   1  FAILED    ECS        hydraulicBearing.badPMCData                                   Sat Apr  4 01:05:41.709 2009  to  Sat Apr  4 01:05:41.709 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   2  FAILED    ECS        instrumentCooling.badPMCData                                  Sat Apr  4 01:05:41.656 2009  to  Sat Apr  4 01:05:41.656 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .   39.51   36.75    0.00   86.26     0.0 %          5          5          5           
                                                                                                   
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .   10.68    7.24    0.00   26.26    50.0 %          5         10                      
                                                                      10.68    7.24    0.00   26.26
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    4.01   18.19   15.63   25.21   100.0 %          5          5                      
                                                                       4.01   18.19   15.63   25.21
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         12                                 
                                                                                                   
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    3.82   10.53    8.11   17.18   100.0 %          5          5                      
                                                                       3.82   10.53    8.11   17.18
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    0.51    4.85    4.27    6.94    88.9 %         45         40                        interrupted =     5
                                                                       0.51    4.85    4.27    6.94
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.00    0.18    0.18    0.18   100.0 %          5          5                      
                                                                       0.00    0.18    0.18    0.18
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.02    0.20    0.17    0.26   100.0 %         35         35                      
                                                                       0.02    0.20    0.17    0.26
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.69    3.19    2.50    3.97   100.0 %          5          5                      
                                                                       0.69    3.19    2.50    3.97

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .       5                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                            35
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .       5                      

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:00:14.824 2009  to  Fri Apr  3 22:01:17.412 2009   ( 62.59) secs
                     guiding was not stable within 6 cycles

   2  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:03:15.116 2009  to  Fri Apr  3 22:04:36.916 2009   ( 81.80) secs
                     guiding was not stable within 6 cycles

   3  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:06:36.230 2009  to  Fri Apr  3 22:07:52.939 2009   ( 76.71) secs
                     guiding was not stable within 6 cycles

   4  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 23:39:16.844 2009  to  Fri Apr  3 23:40:17.031 2009   ( 60.19) secs
                     guiding was not stable within 6 cycles

   5  FAILED    GCS        command.autoAcquireGuidestar                                  Sat Apr  4 01:08:24.922 2009  to  Sat Apr  4 01:09:51.186 2009   ( 86.26) secs
                     guiding was not stable within 6 cycles
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      16                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       7                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             5
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      47                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     163                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.Stowpins.retractWhileEngaging. . . . . . . . . .                             2
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      36                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            67
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            36
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      72                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     229                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           227
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      25                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  8           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .     122                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      86                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       5                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  4           
     MCSPU.ELDrive.Stowpins.stowpinMoving . . . . . . . . . . . . .                  4           
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.OpticalSupport.commandReceived . . . . . . . . . . . . .      11                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 80           
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            16
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      95                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       4                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .     131                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 22           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      32                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  8           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      43                      
     MCSPU.Rotators.resetSerdes . . . . . . . . . . . . . . . . . .                            11
     MCSPU.Tracker.timeDisagreement . . . . . . . . . . . . . . . .                 16           
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.amplifierFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      25                      
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.velocityNotZero. . . . . . . . . . . . . . . . .                  2           
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.earlyFiducial. . . . . . . . . . . . . . . . .                             2
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             2
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.timeDisparity. . . . . . . . . . . . . . . . . .                 11           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .       5                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     103                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     135                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     690                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     226                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeFailSet2. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.commandIgnored. . . . . . . . . . . . .                  8           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Side.doingCommand. . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.OpticalSupport.commandActionReceived . . . . . . . . . .       4                      
     MCSPU.Side.completedCommand. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.SwingArm.startingRetract . . . . . . . . . . . . . . . .       1                      
     MCSPU.Side.spontaneousHalt . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.stowpinCommandRejected . . . . . . . . . . . . .                  3           
     MCSPU.OpticalSupport.cmdRec. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.SwingArm.startingDeploy. . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.commandCompletion . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.deployRetractResult . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnTimeOut. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Diagn.elampsenable . . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 18:37:27.755 2009  to  Fri Apr  3 18:37:27.755 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   2  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 18:40:28.475 2009  to  Fri Apr  3 18:40:28.475 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:40:43.601 2009  to  Fri Apr  3 18:40:43.601 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:40:47.478 2009  to  Fri Apr  3 18:40:47.478 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.102 2009  to  Fri Apr  3 18:43:30.102 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.102 2009  to  Fri Apr  3 18:43:30.102 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:43:30.478 2009  to  Fri Apr  3 18:43:30.478 2009   (  0.00) secs
                     StowIdleIn: LFT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:43:33.437 2009  to  Fri Apr  3 18:43:33.437 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:40:07.544 2009  to  Fri Apr  3 20:40:07.544 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:40:07.547 2009  to  Fri Apr  3 20:40:07.547 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  17  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:40:07.650 2009  to  Fri Apr  3 20:40:07.650 2009   (  0.00) secs
                     drive cabinet has turned on.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:43:49.594 2009  to  Fri Apr  3 20:43:49.594 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:43:49.598 2009  to  Fri Apr  3 20:43:49.598 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:43:49.691 2009  to  Fri Apr  3 20:43:49.691 2009   (  0.00) secs
                     drive cabinet has turned on.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.699 2009  to  Fri Apr  3 20:43:50.699 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.701 2009  to  Fri Apr  3 20:43:50.701 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  35  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:57:31.827 2009  to  Fri Apr  3 20:57:31.827 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:57:31.829 2009  to  Fri Apr  3 20:57:31.829 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  39  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:57:31.932 2009  to  Fri Apr  3 20:57:31.932 2009   (  0.00) secs
                     drive cabinet has turned on.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:57:32.937 2009  to  Fri Apr  3 20:57:32.937 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:33.136 2009  to  Fri Apr  3 21:00:33.136 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-3.021982192993164e+00

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:33.143 2009  to  Fri Apr  3 21:00:33.143 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-3.029980659484863e+00

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:34.175 2009  to  Fri Apr  3 21:00:34.175 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-4.061914443969727e+00

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:34.183 2009  to  Fri Apr  3 21:00:34.183 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-4.069912910461426e+00

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:35.164 2009  to  Fri Apr  3 21:00:35.164 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-5.049851417541504e+00

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:35.223 2009  to  Fri Apr  3 21:00:35.223 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-5.109848022460938e+00

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:36.203 2009  to  Fri Apr  3 21:00:36.203 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-6.089783668518066e+00

  48  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:36.263 2009  to  Fri Apr  3 21:00:36.263 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-6.149784088134766e+00

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:37.243 2009  to  Fri Apr  3 21:00:37.243 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-7.129716873168945e+00

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:37.303 2009  to  Fri Apr  3 21:00:37.303 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-7.189716339111328e+00

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:38.284 2009  to  Fri Apr  3 21:00:38.284 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-8.170331001281738e+00

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:38.343 2009  to  Fri Apr  3 21:00:38.343 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-8.229654312133789e+00

  53  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:39.324 2009  to  Fri Apr  3 21:00:39.324 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-9.210591316223145e+00

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:39.383 2009  to  Fri Apr  3 21:00:39.383 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-9.269619941711426e+00

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:40.365 2009  to  Fri Apr  3 21:00:40.365 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-1.025154018402100e+01

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:40.423 2009  to  Fri Apr  3 21:00:40.423 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-1.030951881408691e+01

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:01:38.579 2009  to  Fri Apr  3 21:01:38.579 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:01:38.583 2009  to  Fri Apr  3 21:01:38.583 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:01:38.688 2009  to  Fri Apr  3 21:01:38.688 2009   (  0.00) secs
                     drive cabinet has turned on.

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:03:01.359 2009  to  Fri Apr  3 21:03:01.359 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:03:01.368 2009  to  Fri Apr  3 21:03:01.368 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  62  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:03:01.465 2009  to  Fri Apr  3 21:03:01.465 2009   (  0.00) secs
                     drive cabinet has turned on.

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:10:20.043 2009  to  Fri Apr  3 21:10:20.043 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:10:20.047 2009  to  Fri Apr  3 21:10:20.047 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:10:20.141 2009  to  Fri Apr  3 21:10:20.141 2009   (  0.00) secs
                     drive cabinet has turned on.

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:14:55.154 2009  to  Fri Apr  3 21:14:55.154 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:14:55.161 2009  to  Fri Apr  3 21:14:55.161 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  68  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:14:55.265 2009  to  Fri Apr  3 21:14:55.265 2009   (  0.00) secs
                     drive cabinet has turned on.

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:29:26.397 2009  to  Fri Apr  3 21:29:26.397 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:29:26.410 2009  to  Fri Apr  3 21:29:26.410 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  71  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:29:26.506 2009  to  Fri Apr  3 21:29:26.506 2009   (  0.00) secs
                     drive cabinet has turned on.

  72  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Fri Apr  3 21:33:32.856 2009  to  Fri Apr  3 21:33:32.856 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  73  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:48.577 2009  to  Fri Apr  3 21:33:48.577 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  74  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:54.251 2009  to  Fri Apr  3 21:33:54.251 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  75  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:57.655 2009  to  Fri Apr  3 21:33:57.655 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  76  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Apr  3 21:35:41.167 2009  to  Fri Apr  3 21:35:41.167 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  77  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Apr  3 21:35:44.761 2009  to  Fri Apr  3 21:35:44.761 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

  78  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Apr  3 21:35:44.871 2009  to  Fri Apr  3 21:35:44.871 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

  79  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 21:35:50.387 2009  to  Fri Apr  3 21:35:50.387 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  80  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 21:35:50.388 2009  to  Fri Apr  3 21:35:50.388 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  81  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:43:06.455 2009  to  Fri Apr  3 21:43:06.455 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  82  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Fri Apr  3 21:43:15.264 2009  to  Fri Apr  3 21:43:15.264 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  83  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Fri Apr  3 21:43:46.277 2009  to  Fri Apr  3 21:43:46.277 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.847 2009  to  Fri Apr  3 21:57:34.847 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888848891e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.745537888848891e+09 seq=0

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.848 2009  to  Fri Apr  3 21:57:34.848 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888850019e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745537888850019e+09 seq=0

  86  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.849 2009  to  Fri Apr  3 21:57:34.849 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888820411e+09 but t0 of the LFBG target polynomial is 0.000000000000000e+00. Difference= 4.745537888820411e+09 seq=0

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 22:11:13.693 2009  to  Fri Apr  3 22:11:13.693 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 22:11:13.730 2009  to  Fri Apr  3 22:11:13.730 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  89  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Apr  3 22:11:14.731 2009  to  Fri Apr  3 22:11:14.731 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 22:19:35.329 2009  to  Fri Apr  3 22:19:35.329 2009   (  0.00) secs
                     MJDsec from DSP is 4.745539209324274e+09 but t0 of the AZ target polynomial is 4.745538706660000e+09. Difference= 5.026642742156982e+02 seq=431845

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 22:19:35.330 2009  to  Fri Apr  3 22:19:35.330 2009   (  0.00) secs
                     MJDsec from DSP is 4.745539209325068e+09 but t0 of the EL target polynomial is 4.745538706660000e+09. Difference= 5.026650686264038e+02 seq=431845

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 23:37:03.441 2009  to  Fri Apr  3 23:37:03.441 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  93  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 23:37:03.471 2009  to  Fri Apr  3 23:37:03.471 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  94  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.492 2009  to  Fri Apr  3 23:37:41.492 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895482929e+09 but t0 of the AZ target polynomial is 4.745543856409000e+09. Difference= 3.907392883300781e+01 seq=534797

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.493 2009  to  Fri Apr  3 23:37:41.493 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895484084e+09 but t0 of the EL target polynomial is 4.745543856409000e+09. Difference= 3.907508373260498e+01 seq=534797

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.494 2009  to  Fri Apr  3 23:37:41.494 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895409586e+09 but t0 of the LFBG target polynomial is 4.745538706660000e+09. Difference= 5.188749586105347e+03 seq=431845

  97  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Apr  4 01:05:34.157 2009  to  Sat Apr  4 01:05:34.157 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  98  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Apr  4 01:05:34.168 2009  to  Sat Apr  4 01:05:34.168 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  99  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat Apr  4 01:05:35.263 2009  to  Sat Apr  4 01:05:35.263 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.331 2009  to  Sat Apr  4 01:07:16.331 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270311828e+09 but t0 of the AZ target polynomial is 4.745549167122000e+09. Difference= 1.031898279190063e+02 seq=640980

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.332 2009  to  Sat Apr  4 01:07:16.332 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270312785e+09 but t0 of the EL target polynomial is 4.745549167122000e+09. Difference= 1.031907854080200e+02 seq=640980

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.333 2009  to  Sat Apr  4 01:07:16.333 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270287866e+09 but t0 of the LFBG target polynomial is 4.745549167122000e+09. Difference= 1.031658658981323e+02 seq=538027

 103  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Sat Apr  4 02:04:25.761 2009  to  Sat Apr  4 02:04:25.761 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

 104  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Sat Apr  4 02:04:25.760 2009  to  Sat Apr  4 02:04:25.760 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 105  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:35.014 2009  to  Sat Apr  4 02:04:35.014 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 106  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:39.503 2009  to  Sat Apr  4 02:04:39.503 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 107  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:48.070 2009  to  Sat Apr  4 02:04:48.070 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 108  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat Apr  4 02:05:34.742 2009  to  Sat Apr  4 02:05:34.742 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 109  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:05:57.228 2009  to  Sat Apr  4 02:05:57.228 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 110  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:06:23.547 2009  to  Sat Apr  4 02:06:23.547 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 111  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:06:56.594 2009  to  Sat Apr  4 02:06:56.594 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 112  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sat Apr  4 02:09:58.670 2009  to  Sat Apr  4 02:09:58.670 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 113  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:12:42.845 2009  to  Sat Apr  4 02:12:42.845 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 114  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:13:13.113 2009  to  Sat Apr  4 02:13:13.113 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 115  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:13:15.157 2009  to  Sat Apr  4 02:13:15.157 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 116  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.cmdRec                                   Sat Apr  4 02:15:11.737 2009  to  Sat Apr  4 02:15:11.737 2009   (  0.00) secs
                     Received a clrreterr command.

 117  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:17:41.653 2009  to  Sat Apr  4 02:17:41.653 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: ignored a stowpin out command because stopwin not lined up

 118  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:17:54.301 2009  to  Sat Apr  4 02:17:54.301 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: ignored a stowpin out command because stopwin not lined up

 119  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:19:41.287 2009  to  Sat Apr  4 02:19:41.287 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 120  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Sat Apr  4 02:19:45.451 2009  to  Sat Apr  4 02:19:45.451 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 121  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:19:50.801 2009  to  Sat Apr  4 02:19:50.801 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 122  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Sat Apr  4 02:19:56.853 2009  to  Sat Apr  4 02:19:56.853 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 123  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:20:19.226 2009  to  Sat Apr  4 02:20:19.226 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    0.31    2.78    2.39    3.15   100.0 %          5          5                      
                                                                       0.31    2.78    2.39    3.15
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.20    3.15    2.94    3.49   100.0 %          5          5                      
                                                                       0.20    3.15    2.94    3.49
     side[0].tertiary_mirror.getfocalstationcount.command . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .   13.90   30.75   14.66   48.97   100.0 %          5          5                      
                                                                      13.90   30.75   14.66   48.97
     side[0].tertiary_mirror.moveselabs.command . . . . . . . . . .    7.61   20.87   15.48   26.25    66.7 %          3          2                      
                                                                       7.61   20.87   15.48   26.25
     side[0].tertiary_mirror.sendstring.command . . . . . . . . . .    0.00    0.08    0.08    0.08   100.0 %          1          1                      
                                                                       0.00    0.08    0.08    0.08
     side[1].sa_structure.clearretracterrors.command. . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     side[1].sa_structure.deployarmas.command . . . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     side[1].sa_structure.deployarmpf.command . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.06
     side[1].sa_structure.getstatusmsg.command. . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %         14         14                      
                                                                       0.00    0.06    0.06    0.06
     side[1].sa_structure.haltselectedarm.command . . . . . . . . .    0.00    0.06    0.06    0.07   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.07
     side[1].sa_structure.powermotoroff.command . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.06
     side[1].sa_structure.powermotoron.command. . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.06
     side[1].sa_structure.retractarmpf.command. . . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     side[1].sa_structure.selectarmnone.command . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06
     side[1].sa_structure.selectarmpf.command . . . . . . . . . . .    0.01    0.07    0.06    0.08   100.0 %          4          4                      
                                                                       0.01    0.07    0.06    0.08

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             7
     side[0].tertiary_mirror.moveselabs.failed. . . . . . . . . . .                  1           

OSS Events of Interest

   1  FAILED    OSS        side[0].tertiary_mirror.moveselabs.failed                     Fri Apr  3 20:19:58.220 2009  to  Fri Apr  3 20:19:58.220 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveSelAbs] Umac brake not set.

   2  SEQERROR  OSS        side[0].tertiary_mirror.moveselabs.command                    Fri Apr  3 20:19:58.166 2009  to  Fri Apr  3 20:20:35.024 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveSelAbs] command.started
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          5          5                      
                                                                       0.00    0.06    0.05    0.06
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.01    0.06    0.05    0.09   100.0 %         35         35                      
                                                                       0.01    0.06    0.05    0.09
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.02    0.06    0.04    0.21   100.0 %         62         62                      
                                                                       0.02    0.06    0.04    0.21
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.69    3.07    2.37    3.84   100.0 %          5          5                        largeUpdate =     5
                                                                       0.69    3.07    2.37    3.84
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.06    0.17    0.13    0.38   100.0 %         36         36                      
                                                                       0.06    0.17    0.13    0.38
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.04    0.05   100.0 %         63         63                      
                                                                       0.00    0.05    0.04    0.05
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.09    0.33    0.23    0.47   100.0 %          5          5                      
                                                                       0.09    0.33    0.23    0.47
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.03    0.08   100.0 %         58         58                      
                                                                       0.01    0.05    0.03    0.08
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.04    0.10    0.06    0.19   100.0 %         10         10                      
                                                                       0.04    0.10    0.06    0.19
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.02    0.41    0.39    0.42   100.0 %          2          2                      
                                                                       0.02    0.41    0.39    0.42
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.11    0.62    0.56    0.82   100.0 %         10         10                      
                                                                       0.11    0.62    0.56    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.04    0.03    0.00    0.08     0.0 %          4                     4           
                                                                       0.03    0.06    0.04    0.08

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 22:11:12.521 2009  to  Fri Apr  3 22:11:12.586 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   2  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 22:11:12.730 2009  to  Fri Apr  3 22:11:12.730 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   3  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 23:37:02.322 2009  to  Fri Apr  3 23:37:02.392 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   4  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 23:37:02.501 2009  to  Fri Apr  3 23:37:02.501 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   5  SHUTDOWN  PCS        shutdown                                                      Sat Apr  4 01:05:33.274 2009  to  Sat Apr  4 01:05:33.274 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33g

   6  STARTUP   PCS        startup                                                       Sat Apr  4 01:06:07.787 2009  to  Sat Apr  4 01:06:07.787 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.06    1.06    1.06   100.0 %          1          1                      
                                                                       0.00    1.06    1.06    1.06
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.07    0.49    0.44    0.54   100.0 %          2          2                      
                                                                       0.07    0.49    0.44    0.54
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.17   66.17   66.17   100.0 %          1          1                      
                                                                       0.00   66.17   66.17   66.17
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .   14.63    7.30    0.00   83.21    49.0 %         51         25         26           
                                                                      18.39   15.33    2.06   83.21
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  239.64  239.64  239.64   100.0 %          1          1                      
                                                                       0.00  239.64  239.64  239.64
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          1          1                      
                                                                       0.00    0.06    0.06    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      40                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      41                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  7           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      22                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             3
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                            22
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                            18
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                            15
     cellStatus.telemetryError. . . . . . . . . . . . . . . . . . .                  2           
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       2                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       2                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       2                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                             2
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 18:45:29.981 2009  to  Fri Apr  3 18:45:33.043 2009   (  3.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr  3 20:55:42.852 2009  to  Fri Apr  3 20:55:42.852 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   3  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr  3 20:55:42.906 2009  to  Fri Apr  3 20:55:42.906 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

   4  FAILED    PMC        thermal.badReceive                                            Fri Apr  3 20:55:42.956 2009  to  Fri Apr  3 20:55:42.956 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   5  FAILED    PMC        VxInterface.lengthError                                       Fri Apr  3 22:06:33.044 2009  to  Fri Apr  3 22:06:33.044 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

   6  FAILED    PMC        VxInterface.close                                             Fri Apr  3 22:06:33.096 2009  to  Fri Apr  3 22:06:33.096 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:20:04.876 2009  to  Fri Apr  3 22:20:04.930 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:20:49.358 2009  to  Fri Apr  3 22:20:49.412 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:23:05.899 2009  to  Fri Apr  3 22:23:05.953 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:26:15.181 2009  to  Fri Apr  3 22:26:15.234 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:27:14.599 2009  to  Fri Apr  3 22:27:14.652 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:27:15.688 2009  to  Fri Apr  3 22:27:15.740 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  13  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:29:48.968 2009  to  Fri Apr  3 22:29:49.024 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:32:33.129 2009  to  Fri Apr  3 22:32:33.185 2009   (  0.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:33:43.747 2009  to  Fri Apr  3 22:33:43.799 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:33:44.933 2009  to  Fri Apr  3 22:33:44.988 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  17  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:36:18.260 2009  to  Fri Apr  3 22:36:18.313 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:39:00.451 2009  to  Fri Apr  3 22:39:00.503 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:41:30.661 2009  to  Fri Apr  3 22:41:30.714 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  20  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:52:20.437 2009  to  Fri Apr  3 22:52:20.492 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  21  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:52:24.220 2009  to  Fri Apr  3 22:52:24.274 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  22  FAILED    PMC        VxInterface.close                                             Fri Apr  3 22:52:31.681 2009  to  Fri Apr  3 22:52:31.681 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Fri Apr  3 22:52:31.629 2009  to  Fri Apr  3 22:52:31.629 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:53:15.767 2009  to  Fri Apr  3 22:53:15.820 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:55:49.043 2009  to  Fri Apr  3 22:55:49.097 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  26  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:58:32.965 2009  to  Fri Apr  3 22:58:33.017 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:19:53.325 2009  to  Fri Apr  3 23:19:53.377 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  28  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr  3 23:20:35.166 2009  to  Fri Apr  3 23:20:35.166 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  29  FAILED    PMC        thermal.badReceive                                            Fri Apr  3 23:20:35.270 2009  to  Fri Apr  3 23:20:35.270 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  30  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr  3 23:20:35.218 2009  to  Fri Apr  3 23:20:35.218 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  31  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.175 2009  to  Fri Apr  3 23:22:18.228 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  32  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.173 2009  to  Fri Apr  3 23:22:18.294 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.294 2009  to  Fri Apr  3 23:22:18.348 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  34  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.302 2009  to  Fri Apr  3 23:22:18.355 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  35  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:23:03.325 2009  to  Fri Apr  3 23:23:03.325 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  36  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:29:46.871 2009  to  Sat Apr  4 00:29:46.871 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  37  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:29:46.977 2009  to  Sat Apr  4 00:29:46.977 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  38  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:29:46.924 2009  to  Sat Apr  4 00:29:46.924 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  39  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:30:08.230 2009  to  Sat Apr  4 00:30:08.230 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  40  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:30:08.178 2009  to  Sat Apr  4 00:30:08.178 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  41  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:30:08.282 2009  to  Sat Apr  4 00:30:08.282 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  42  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:48:26.816 2009  to  Sat Apr  4 00:48:26.816 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  43  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:48:26.762 2009  to  Sat Apr  4 00:48:26.762 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  44  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:48:26.868 2009  to  Sat Apr  4 00:48:26.868 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  45  FAILED    PMC        cellStatus.telemetryError                                     Sat Apr  4 01:05:36.341 2009  to  Sat Apr  4 01:05:36.341 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: 2006: MySQL server has gone away

  46  SHUTDOWN  PMC        shutdown                                                      Sat Apr  4 01:05:36.394 2009  to  Sat Apr  4 01:05:36.394 2009   (  0.00) secs
                     right PMC subsystem shut down

  47  FAILED    PMC        cellStatus.telemetryError                                     Sat Apr  4 01:05:40.296 2009  to  Sat Apr  4 01:05:40.296 2009   (  0.00) secs
                     left PMC CellStatus telemetry error: 2006: MySQL server has gone away

  48  SHUTDOWN  PMC        shutdown                                                      Sat Apr  4 01:05:40.348 2009  to  Sat Apr  4 01:05:40.348 2009   (  0.00) secs
                     left PMC subsystem shut down

  49  FAILED    PMC        actuator.telemetryError                                       Sat Apr  4 01:05:50.123 2009  to  Sat Apr  4 01:05:50.123 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  50  STARTUP   PMC        startup                                                       Sat Apr  4 01:05:53.316 2009  to  Sat Apr  4 01:05:53.316 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

  51  FAILED    PMC        actuator.telemetryError                                       Sat Apr  4 01:06:00.223 2009  to  Sat Apr  4 01:06:00.223 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  52  STARTUP   PMC        startup                                                       Sat Apr  4 01:06:04.167 2009  to  Sat Apr  4 01:06:04.167 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

  53  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 03:29:21.988 2009  to  Sat Apr  4 03:29:21.988 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  54  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 03:29:22.093 2009  to  Sat Apr  4 03:29:22.093 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  55  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 03:29:22.041 2009  to  Sat Apr  4 03:29:22.041 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  56  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 03:31:23.918 2009  to  Sat Apr  4 03:31:23.918 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  57  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 03:31:23.866 2009  to  Sat Apr  4 03:31:23.866 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  58  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 03:31:23.971 2009  to  Sat Apr  4 03:31:23.971 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.33    2.05    0.40    3.69   100.0 %          2          2                      
                                                                       2.33    2.05    0.40    3.69
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.11    0.12    0.05    0.27   100.0 %         15         15                      
                                                                       0.11    0.12    0.05    0.27
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.22    4.71    0.39   15.44    44.1 %         34         15         19           
                                                                       2.75   10.15    6.40   15.44
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.35    0.36    0.05    0.71    75.0 %          4          3          1           
                                                                       0.38    0.27    0.05    0.71
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.33    2.15    0.51    3.80   100.0 %          2          2                      
                                                                       2.33    2.15    0.51    3.80
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.32    1.83    0.19    3.47   100.0 %          2          2                      
                                                                       2.32    1.83    0.19    3.47
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   14.63    7.46    0.00   83.38    49.0 %         51         25         26           
                                                                      18.39   15.47    2.23   83.38
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.18    2.18    2.18   100.0 %          1          1                      
                                                                       0.00    2.18    2.18    2.18
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.03    0.26    0.23    0.28    50.0 %          2          1          1           
                                                                       0.00    0.28    0.28    0.28
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.23    4.60    0.29   15.32    44.1 %         34         15         19           
                                                                       2.74   10.04    6.30   15.32
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.00    0.05    0.05    0.05   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.05
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    3.31    3.31    3.31     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    0.31    2.91    2.52    3.28   100.0 %          5          5                      
                                                                       0.31    2.91    2.52    3.28
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.02    0.10    0.09    0.12   100.0 %          2          2                      
                                                                       0.02    0.10    0.09    0.12
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    0.20    3.28    3.07    3.61   100.0 %          5          5                      
                                                                       0.20    3.28    3.07    3.61
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.02    0.08    0.07    0.10   100.0 %          2          2                      
                                                                       0.02    0.08    0.07    0.10

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Fri Apr  3 18:45:29.855 2009  to  Fri Apr  3 18:45:33.167 2009   (  3.31) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 18:45:29.910 2009  to  Fri Apr  3 18:45:33.110 2009   (  3.20) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        command.setNewInstrument                                      Fri Apr  3 22:11:13.356 2009  to  Fri Apr  3 22:11:13.969 2009   (  0.61) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

   4  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Apr  3 22:11:13.409 2009  to  Fri Apr  3 22:11:13.643 2009   (  0.23) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:20:03.422 2009  to  Fri Apr  3 22:20:05.117 2009   (  1.69) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   6  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:20:49.187 2009  to  Fri Apr  3 22:20:49.593 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

   7  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:20:49.247 2009  to  Fri Apr  3 22:20:49.536 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:20:49.299 2009  to  Fri Apr  3 22:20:49.480 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   9  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:23:05.732 2009  to  Fri Apr  3 22:23:06.131 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:23:05.836 2009  to  Fri Apr  3 22:23:06.022 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  11  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:23:05.784 2009  to  Fri Apr  3 22:23:06.076 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  12  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:26:15.013 2009  to  Fri Apr  3 22:26:15.413 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  13  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:26:15.067 2009  to  Fri Apr  3 22:26:15.357 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  14  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:26:15.119 2009  to  Fri Apr  3 22:26:15.302 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  15  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:27:14.433 2009  to  Fri Apr  3 22:27:14.828 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  16  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:27:14.485 2009  to  Fri Apr  3 22:27:14.773 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:27:14.537 2009  to  Fri Apr  3 22:27:14.718 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  18  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:27:15.521 2009  to  Fri Apr  3 22:27:15.922 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  19  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:27:15.627 2009  to  Fri Apr  3 22:27:15.812 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  20  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:27:15.574 2009  to  Fri Apr  3 22:27:15.867 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  21  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:29:48.801 2009  to  Fri Apr  3 22:29:49.209 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

  22  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:29:48.908 2009  to  Fri Apr  3 22:29:49.096 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  23  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:29:48.855 2009  to  Fri Apr  3 22:29:49.153 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  24  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:32:32.964 2009  to  Fri Apr  3 22:32:33.376 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

  25  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:32:33.068 2009  to  Fri Apr  3 22:32:33.257 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  26  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:32:33.016 2009  to  Fri Apr  3 22:32:33.316 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  27  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:33:43.578 2009  to  Fri Apr  3 22:33:43.982 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  28  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:33:43.631 2009  to  Fri Apr  3 22:33:43.926 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:33:43.685 2009  to  Fri Apr  3 22:33:43.869 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  30  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:33:44.766 2009  to  Fri Apr  3 22:33:45.176 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

  31  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:33:44.871 2009  to  Fri Apr  3 22:33:45.065 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  32  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:33:44.818 2009  to  Fri Apr  3 22:33:45.120 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  33  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:36:18.097 2009  to  Fri Apr  3 22:36:18.491 2009   (  0.39) secs
                     right PSF SetInstrumentOffsets failed

  34  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:36:18.149 2009  to  Fri Apr  3 22:36:18.435 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:36:18.201 2009  to  Fri Apr  3 22:36:18.380 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  36  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:39:00.284 2009  to  Fri Apr  3 22:39:00.703 2009   (  0.42) secs
                     right PSF SetInstrumentOffsets failed

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:39:00.390 2009  to  Fri Apr  3 22:39:00.572 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  38  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:39:00.338 2009  to  Fri Apr  3 22:39:00.628 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  39  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:41:30.492 2009  to  Fri Apr  3 22:41:30.911 2009   (  0.42) secs
                     right PSF SetInstrumentOffsets failed

  40  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:41:30.544 2009  to  Fri Apr  3 22:41:30.851 2009   (  0.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  41  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:41:30.598 2009  to  Fri Apr  3 22:41:30.791 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:52:20.356 2009  to  Fri Apr  3 22:52:20.562 2009   (  0.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  43  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:52:24.054 2009  to  Fri Apr  3 22:52:24.455 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  44  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:52:24.109 2009  to  Fri Apr  3 22:52:24.399 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  45  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:52:24.161 2009  to  Fri Apr  3 22:52:24.344 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  46  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:53:15.604 2009  to  Fri Apr  3 22:53:16.032 2009   (  0.43) secs
                     right PSF SetInstrumentOffsets failed

  47  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:53:15.656 2009  to  Fri Apr  3 22:53:15.947 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:53:15.708 2009  to  Fri Apr  3 22:53:15.892 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  49  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:55:48.875 2009  to  Fri Apr  3 22:55:49.273 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  50  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:55:48.927 2009  to  Fri Apr  3 22:55:49.218 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:55:48.979 2009  to  Fri Apr  3 22:55:49.164 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  52  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:58:32.797 2009  to  Fri Apr  3 22:58:33.196 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  53  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:58:32.850 2009  to  Fri Apr  3 22:58:33.140 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:58:32.903 2009  to  Fri Apr  3 22:58:33.085 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  55  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:19:53.259 2009  to  Fri Apr  3 23:19:53.444 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  56  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.104 2009  to  Fri Apr  3 23:22:18.232 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  57  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.112 2009  to  Fri Apr  3 23:22:18.237 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.232 2009  to  Fri Apr  3 23:22:18.414 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  59  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.237 2009  to  Fri Apr  3 23:22:18.302 2009   (  0.06) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  60  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.424 2009  to  Fri Apr  3 23:22:18.424 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  61  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:23:04.161 2009  to  Fri Apr  3 23:23:04.559 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  62  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:23:04.213 2009  to  Fri Apr  3 23:23:04.505 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  63  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:25:20.360 2009  to  Fri Apr  3 23:25:20.865 2009   (  0.51) secs
                     right PSF SetInstrumentOffsets failed

  64  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:25:20.413 2009  to  Fri Apr  3 23:25:20.791 2009   (  0.38) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  65  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:27:25.228 2009  to  Fri Apr  3 23:27:25.655 2009   (  0.43) secs
                     right PSF SetInstrumentOffsets failed

  66  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:27:25.283 2009  to  Fri Apr  3 23:27:25.573 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 18:37:27.755 2009  to  Fri Apr  3 18:37:27.755 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   2  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 18:40:28.475 2009  to  Fri Apr  3 18:40:28.475 2009   (  0.00) secs
                     A brake command failed to complete successfully.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:40:43.601 2009  to  Fri Apr  3 18:40:43.601 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:40:47.478 2009  to  Fri Apr  3 18:40:47.478 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: stowpin is moving but hasn''t been commanded to move.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.100 2009  to  Fri Apr  3 18:43:30.100 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.101 2009  to  Fri Apr  3 18:43:30.101 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.102 2009  to  Fri Apr  3 18:43:30.102 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 18:43:30.102 2009  to  Fri Apr  3 18:43:30.102 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:43:30.478 2009  to  Fri Apr  3 18:43:30.478 2009   (  0.00) secs
                     StowIdleIn: LFT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Apr  3 18:43:33.437 2009  to  Fri Apr  3 18:43:33.437 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  15  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Fri Apr  3 18:45:29.855 2009  to  Fri Apr  3 18:45:33.167 2009   (  3.31) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 18:45:29.910 2009  to  Fri Apr  3 18:45:33.110 2009   (  3.20) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 18:45:29.981 2009  to  Fri Apr  3 18:45:33.043 2009   (  3.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    OSS        side[0].tertiary_mirror.moveselabs.failed                     Fri Apr  3 20:19:58.220 2009  to  Fri Apr  3 20:19:58.220 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveSelAbs] Umac brake not set.

  19  SEQERROR  OSS        side[0].tertiary_mirror.moveselabs.command                    Fri Apr  3 20:19:58.166 2009  to  Fri Apr  3 20:20:35.024 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveSelAbs] command.started

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:40:07.544 2009  to  Fri Apr  3 20:40:07.544 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:40:07.547 2009  to  Fri Apr  3 20:40:07.547 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  22  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:40:07.650 2009  to  Fri Apr  3 20:40:07.650 2009   (  0.00) secs
                     drive cabinet has turned on.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.659 2009  to  Fri Apr  3 20:40:08.659 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:40:08.660 2009  to  Fri Apr  3 20:40:08.660 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:43:49.594 2009  to  Fri Apr  3 20:43:49.594 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:43:49.598 2009  to  Fri Apr  3 20:43:49.598 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:43:49.691 2009  to  Fri Apr  3 20:43:49.691 2009   (  0.00) secs
                     drive cabinet has turned on.

  34  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.699 2009  to  Fri Apr  3 20:43:50.699 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  35  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  37  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.700 2009  to  Fri Apr  3 20:43:50.700 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.701 2009  to  Fri Apr  3 20:43:50.701 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:43:50.702 2009  to  Fri Apr  3 20:43:50.702 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  42  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr  3 20:55:42.852 2009  to  Fri Apr  3 20:55:42.852 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  43  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr  3 20:55:42.906 2009  to  Fri Apr  3 20:55:42.906 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  44  FAILED    PMC        thermal.badReceive                                            Fri Apr  3 20:55:42.956 2009  to  Fri Apr  3 20:55:42.956 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:57:31.827 2009  to  Fri Apr  3 20:57:31.827 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 20:57:31.829 2009  to  Fri Apr  3 20:57:31.829 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 20:57:31.932 2009  to  Fri Apr  3 20:57:31.932 2009   (  0.00) secs
                     drive cabinet has turned on.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Apr  3 20:57:32.937 2009  to  Fri Apr  3 20:57:32.937 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:33.136 2009  to  Fri Apr  3 21:00:33.136 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-3.021982192993164e+00

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:33.143 2009  to  Fri Apr  3 21:00:33.143 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-3.029980659484863e+00

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:34.175 2009  to  Fri Apr  3 21:00:34.175 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-4.061914443969727e+00

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:34.183 2009  to  Fri Apr  3 21:00:34.183 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-4.069912910461426e+00

  53  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:35.164 2009  to  Fri Apr  3 21:00:35.164 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-5.049851417541504e+00

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:35.223 2009  to  Fri Apr  3 21:00:35.223 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-5.109848022460938e+00

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:36.203 2009  to  Fri Apr  3 21:00:36.203 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-6.089783668518066e+00

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:36.263 2009  to  Fri Apr  3 21:00:36.263 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-6.149784088134766e+00

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:37.243 2009  to  Fri Apr  3 21:00:37.243 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-7.129716873168945e+00

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:37.303 2009  to  Fri Apr  3 21:00:37.303 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-7.189716339111328e+00

  59  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:38.284 2009  to  Fri Apr  3 21:00:38.284 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-8.170331001281738e+00

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:38.343 2009  to  Fri Apr  3 21:00:38.343 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-8.229654312133789e+00

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:39.324 2009  to  Fri Apr  3 21:00:39.324 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-9.210591316223145e+00

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:39.383 2009  to  Fri Apr  3 21:00:39.383 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-9.269619941711426e+00

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:40.365 2009  to  Fri Apr  3 21:00:40.365 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-1.025154018402100e+01

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisagreement                                Fri Apr  3 21:00:40.423 2009  to  Fri Apr  3 21:00:40.423 2009   (  0.00) secs
                     DSP has MJDsec=4.745534464113548e+09. Linux has MJDsec= %d. Difference =-1.030951881408691e+01

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:01:38.579 2009  to  Fri Apr  3 21:01:38.579 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:01:38.583 2009  to  Fri Apr  3 21:01:38.583 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:01:38.688 2009  to  Fri Apr  3 21:01:38.688 2009   (  0.00) secs
                     drive cabinet has turned on.

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:03:01.359 2009  to  Fri Apr  3 21:03:01.359 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:03:01.368 2009  to  Fri Apr  3 21:03:01.368 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:03:01.465 2009  to  Fri Apr  3 21:03:01.465 2009   (  0.00) secs
                     drive cabinet has turned on.

  71  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:10:20.043 2009  to  Fri Apr  3 21:10:20.043 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  72  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:10:20.047 2009  to  Fri Apr  3 21:10:20.047 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  73  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:10:20.141 2009  to  Fri Apr  3 21:10:20.141 2009   (  0.00) secs
                     drive cabinet has turned on.

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:14:55.154 2009  to  Fri Apr  3 21:14:55.154 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:14:55.161 2009  to  Fri Apr  3 21:14:55.161 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  76  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:14:55.265 2009  to  Fri Apr  3 21:14:55.265 2009   (  0.00) secs
                     drive cabinet has turned on.

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:29:26.397 2009  to  Fri Apr  3 21:29:26.397 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  78  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 21:29:26.410 2009  to  Fri Apr  3 21:29:26.410 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  79  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Apr  3 21:29:26.506 2009  to  Fri Apr  3 21:29:26.506 2009   (  0.00) secs
                     drive cabinet has turned on.

  80  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Fri Apr  3 21:33:32.856 2009  to  Fri Apr  3 21:33:32.856 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  81  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:48.577 2009  to  Fri Apr  3 21:33:48.577 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  82  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:54.251 2009  to  Fri Apr  3 21:33:54.251 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  83  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:33:57.655 2009  to  Fri Apr  3 21:33:57.655 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  84  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Apr  3 21:35:41.167 2009  to  Fri Apr  3 21:35:41.167 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  85  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Apr  3 21:35:44.761 2009  to  Fri Apr  3 21:35:44.761 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

  86  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Apr  3 21:35:44.871 2009  to  Fri Apr  3 21:35:44.871 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

  87  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 21:35:50.387 2009  to  Fri Apr  3 21:35:50.387 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  88  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Apr  3 21:35:50.388 2009  to  Fri Apr  3 21:35:50.388 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  89  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Apr  3 21:43:06.455 2009  to  Fri Apr  3 21:43:06.455 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  90  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Fri Apr  3 21:43:15.264 2009  to  Fri Apr  3 21:43:15.264 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  91  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Fri Apr  3 21:43:46.277 2009  to  Fri Apr  3 21:43:46.277 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  92  FAILED    IIF        command.preset.(GUIDE)                                        Fri Apr  3 21:57:33.845 2009  to  Fri Apr  3 22:01:17.938 2009   (224.09) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left IRTC mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 443
                     IIF Preset alert for left IRTC mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left IRTC mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode GUIDE from IIF

  93  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.847 2009  to  Fri Apr  3 21:57:34.847 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888848891e+09 but t0 of the AZ target polynomial is 0.000000000000000e+00. Difference= 4.745537888848891e+09 seq=0

  94  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.848 2009  to  Fri Apr  3 21:57:34.848 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888850019e+09 but t0 of the EL target polynomial is 0.000000000000000e+00. Difference= 4.745537888850019e+09 seq=0

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 21:57:34.849 2009  to  Fri Apr  3 21:57:34.849 2009   (  0.00) secs
                     MJDsec from DSP is 4.745537888820411e+09 but t0 of the LFBG target polynomial is 0.000000000000000e+00. Difference= 4.745537888820411e+09 seq=0

  96  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:00:14.824 2009  to  Fri Apr  3 22:01:17.412 2009   ( 62.59) secs
                     guiding was not stable within 6 cycles

  97  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 22:02:23.998 2009  to  Fri Apr  3 22:04:37.315 2009   (133.32) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 4082 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

  98  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:03:15.116 2009  to  Fri Apr  3 22:04:36.916 2009   ( 81.80) secs
                     guiding was not stable within 6 cycles

  99  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 22:06:12.146 2009  to  Fri Apr  3 22:07:53.347 2009   (101.20) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 100  FAILED    PMC        VxInterface.lengthError                                       Fri Apr  3 22:06:33.044 2009  to  Fri Apr  3 22:06:33.044 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 101  FAILED    PMC        VxInterface.close                                             Fri Apr  3 22:06:33.096 2009  to  Fri Apr  3 22:06:33.096 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 102  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 22:06:36.230 2009  to  Fri Apr  3 22:07:52.939 2009   ( 76.71) secs
                     guiding was not stable within 6 cycles

 103  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Apr  3 22:11:12.452 2009  to  Fri Apr  3 22:11:14.194 2009   (  1.74) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

 104  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 22:11:12.521 2009  to  Fri Apr  3 22:11:12.586 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 105  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 22:11:12.730 2009  to  Fri Apr  3 22:11:12.730 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 106  FAILED    PSF        command.setNewInstrument                                      Fri Apr  3 22:11:13.356 2009  to  Fri Apr  3 22:11:13.969 2009   (  0.61) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

 107  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Apr  3 22:11:13.409 2009  to  Fri Apr  3 22:11:13.643 2009   (  0.23) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 108  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 22:11:13.693 2009  to  Fri Apr  3 22:11:13.693 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 22:11:13.730 2009  to  Fri Apr  3 22:11:13.730 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 110  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Apr  3 22:11:14.731 2009  to  Fri Apr  3 22:11:14.731 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 111  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 22:19:34.548 2009  to  Fri Apr  3 22:20:47.827 2009   ( 73.28) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

 112  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 22:19:35.329 2009  to  Fri Apr  3 22:19:35.329 2009   (  0.00) secs
                     MJDsec from DSP is 4.745539209324274e+09 but t0 of the AZ target polynomial is 4.745538706660000e+09. Difference= 5.026642742156982e+02 seq=431845

 113  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 22:19:35.330 2009  to  Fri Apr  3 22:19:35.330 2009   (  0.00) secs
                     MJDsec from DSP is 4.745539209325068e+09 but t0 of the EL target polynomial is 4.745538706660000e+09. Difference= 5.026650686264038e+02 seq=431845

 114  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:20:03.422 2009  to  Fri Apr  3 22:20:05.117 2009   (  1.69) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 115  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:20:04.876 2009  to  Fri Apr  3 22:20:04.930 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 116  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:20:49.120 2009  to  Fri Apr  3 22:20:49.792 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 117  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:20:49.187 2009  to  Fri Apr  3 22:20:49.593 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

 118  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:20:49.247 2009  to  Fri Apr  3 22:20:49.536 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 119  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:20:49.299 2009  to  Fri Apr  3 22:20:49.480 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 120  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:20:49.358 2009  to  Fri Apr  3 22:20:49.412 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 121  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:23:05.668 2009  to  Fri Apr  3 22:23:06.300 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 122  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:23:05.732 2009  to  Fri Apr  3 22:23:06.131 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 123  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:23:05.836 2009  to  Fri Apr  3 22:23:06.022 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 124  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:23:05.784 2009  to  Fri Apr  3 22:23:06.076 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 125  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:23:05.899 2009  to  Fri Apr  3 22:23:05.953 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 126  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:26:14.947 2009  to  Fri Apr  3 22:26:15.583 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 127  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:26:15.013 2009  to  Fri Apr  3 22:26:15.413 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 128  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:26:15.067 2009  to  Fri Apr  3 22:26:15.357 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 129  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:26:15.119 2009  to  Fri Apr  3 22:26:15.302 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 130  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:26:15.181 2009  to  Fri Apr  3 22:26:15.234 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 131  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:27:14.433 2009  to  Fri Apr  3 22:27:14.828 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 132  FAILED    IIF        command.stepFocus                                             Fri Apr  3 22:27:14.369 2009  to  Fri Apr  3 22:27:15.134 2009   (  0.76) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 133  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:27:14.485 2009  to  Fri Apr  3 22:27:14.773 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 134  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:27:14.599 2009  to  Fri Apr  3 22:27:14.652 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 135  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:27:14.537 2009  to  Fri Apr  3 22:27:14.718 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 136  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:27:15.453 2009  to  Fri Apr  3 22:27:16.094 2009   (  0.64) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 137  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:27:15.521 2009  to  Fri Apr  3 22:27:15.922 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 138  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:27:15.627 2009  to  Fri Apr  3 22:27:15.812 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 139  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:27:15.574 2009  to  Fri Apr  3 22:27:15.867 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 140  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:27:15.688 2009  to  Fri Apr  3 22:27:15.740 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 141  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:29:48.735 2009  to  Fri Apr  3 22:29:49.377 2009   (  0.64) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 142  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:29:48.801 2009  to  Fri Apr  3 22:29:49.209 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

 143  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:29:48.908 2009  to  Fri Apr  3 22:29:49.096 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 144  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:29:48.855 2009  to  Fri Apr  3 22:29:49.153 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 145  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:29:48.968 2009  to  Fri Apr  3 22:29:49.024 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 146  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:32:32.900 2009  to  Fri Apr  3 22:32:33.548 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 147  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:32:32.964 2009  to  Fri Apr  3 22:32:33.376 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

 148  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:32:33.068 2009  to  Fri Apr  3 22:32:33.257 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 149  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:32:33.016 2009  to  Fri Apr  3 22:32:33.316 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 150  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:32:33.129 2009  to  Fri Apr  3 22:32:33.185 2009   (  0.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 151  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:33:43.578 2009  to  Fri Apr  3 22:33:43.982 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 152  FAILED    IIF        command.stepFocus                                             Fri Apr  3 22:33:43.513 2009  to  Fri Apr  3 22:33:44.150 2009   (  0.64) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 153  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:33:43.631 2009  to  Fri Apr  3 22:33:43.926 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 154  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:33:43.747 2009  to  Fri Apr  3 22:33:43.799 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 155  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:33:43.685 2009  to  Fri Apr  3 22:33:43.869 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 156  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:33:44.701 2009  to  Fri Apr  3 22:33:45.346 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 157  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:33:44.766 2009  to  Fri Apr  3 22:33:45.176 2009   (  0.41) secs
                     right PSF SetInstrumentOffsets failed

 158  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:33:44.871 2009  to  Fri Apr  3 22:33:45.065 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 159  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:33:44.818 2009  to  Fri Apr  3 22:33:45.120 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 160  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:33:44.933 2009  to  Fri Apr  3 22:33:44.988 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 161  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:36:18.033 2009  to  Fri Apr  3 22:36:18.658 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 162  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:36:18.097 2009  to  Fri Apr  3 22:36:18.491 2009   (  0.39) secs
                     right PSF SetInstrumentOffsets failed

 163  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:36:18.149 2009  to  Fri Apr  3 22:36:18.435 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 164  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:36:18.201 2009  to  Fri Apr  3 22:36:18.380 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 165  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:36:18.260 2009  to  Fri Apr  3 22:36:18.313 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 166  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:39:00.217 2009  to  Fri Apr  3 22:39:00.869 2009   (  0.65) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 167  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:39:00.284 2009  to  Fri Apr  3 22:39:00.703 2009   (  0.42) secs
                     right PSF SetInstrumentOffsets failed

 168  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:39:00.390 2009  to  Fri Apr  3 22:39:00.572 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 169  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:39:00.338 2009  to  Fri Apr  3 22:39:00.628 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 170  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:39:00.451 2009  to  Fri Apr  3 22:39:00.503 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 171  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:41:30.329 2009  to  Fri Apr  3 22:41:31.085 2009   (  0.76) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 172  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:41:30.492 2009  to  Fri Apr  3 22:41:30.911 2009   (  0.42) secs
                     right PSF SetInstrumentOffsets failed

 173  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:41:30.544 2009  to  Fri Apr  3 22:41:30.851 2009   (  0.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 174  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:41:30.661 2009  to  Fri Apr  3 22:41:30.714 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 175  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:41:30.598 2009  to  Fri Apr  3 22:41:30.791 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 176  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 22:52:17.863 2009  to  Fri Apr  3 22:52:22.821 2009   (  4.96) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

 177  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:52:20.356 2009  to  Fri Apr  3 22:52:20.562 2009   (  0.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 178  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:52:20.437 2009  to  Fri Apr  3 22:52:20.492 2009   (  0.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 179  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:52:23.987 2009  to  Fri Apr  3 22:52:24.624 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 180  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:52:24.054 2009  to  Fri Apr  3 22:52:24.455 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 181  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:52:24.109 2009  to  Fri Apr  3 22:52:24.399 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 182  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:52:24.161 2009  to  Fri Apr  3 22:52:24.344 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 183  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:52:24.220 2009  to  Fri Apr  3 22:52:24.274 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 184  FAILED    PMC        VxInterface.close                                             Fri Apr  3 22:52:31.681 2009  to  Fri Apr  3 22:52:31.681 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 185  FAILED    PMC        VxInterface.lengthError                                       Fri Apr  3 22:52:31.629 2009  to  Fri Apr  3 22:52:31.629 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 186  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:53:15.604 2009  to  Fri Apr  3 22:53:16.032 2009   (  0.43) secs
                     right PSF SetInstrumentOffsets failed

 187  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:53:15.537 2009  to  Fri Apr  3 22:53:16.201 2009   (  0.66) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 188  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:53:15.656 2009  to  Fri Apr  3 22:53:15.947 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 189  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:53:15.767 2009  to  Fri Apr  3 22:53:15.820 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 190  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:53:15.708 2009  to  Fri Apr  3 22:53:15.892 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 191  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:55:48.768 2009  to  Fri Apr  3 22:55:49.441 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 192  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:55:48.875 2009  to  Fri Apr  3 22:55:49.273 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 193  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:55:48.927 2009  to  Fri Apr  3 22:55:49.218 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 194  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:55:49.043 2009  to  Fri Apr  3 22:55:49.097 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 195  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:55:48.979 2009  to  Fri Apr  3 22:55:49.164 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 196  FAILED    IIF        command.moveFocus                                             Fri Apr  3 22:58:32.733 2009  to  Fri Apr  3 22:58:33.367 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 2.200000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 197  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 22:58:32.797 2009  to  Fri Apr  3 22:58:33.196 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 198  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 22:58:32.850 2009  to  Fri Apr  3 22:58:33.140 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 199  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 22:58:32.903 2009  to  Fri Apr  3 22:58:33.085 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 200  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 22:58:32.965 2009  to  Fri Apr  3 22:58:33.017 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 201  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 23:19:50.520 2009  to  Fri Apr  3 23:20:03.709 2009   ( 13.19) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

 202  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:19:53.259 2009  to  Fri Apr  3 23:19:53.444 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 203  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:19:53.325 2009  to  Fri Apr  3 23:19:53.377 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 204  FAILED    PMC        VxInterface.selectTimeout                                     Fri Apr  3 23:20:35.166 2009  to  Fri Apr  3 23:20:35.166 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 205  FAILED    PMC        thermal.badReceive                                            Fri Apr  3 23:20:35.270 2009  to  Fri Apr  3 23:20:35.270 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 206  FAILED    PMC        VxInterface.packetReadError                                   Fri Apr  3 23:20:35.218 2009  to  Fri Apr  3 23:20:35.218 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 207  SEQERROR  IIF        command.preset.(TRACK)                                        Fri Apr  3 23:21:28.691 2009  to  Fri Apr  3 23:21:45.626 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for both LBC mode TRACK from IIF

 208  SEQERROR  IIF        command.preset.elevationWait                                  Fri Apr  3 23:21:30.035 2009  to  Fri Apr  3 23:21:46.934 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

 209  FAILED    IIF        command.preset.(TRACK)                                        Fri Apr  3 23:21:45.626 2009  to  Fri Apr  3 23:22:18.656 2009   ( 33.03) secs
                     IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF Preset command failed for both LBC mode TRACK from IIF

 210  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.104 2009  to  Fri Apr  3 23:22:18.232 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 211  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.112 2009  to  Fri Apr  3 23:22:18.237 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 212  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.175 2009  to  Fri Apr  3 23:22:18.228 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 213  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.173 2009  to  Fri Apr  3 23:22:18.294 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 214  SEQERROR  IIF        command.preset.elevationWait                                  Fri Apr  3 23:22:18.172 2009  to  Fri Apr  3 23:22:18.172 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Preset command wait for elevation complete for both LBC

 215  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.232 2009  to  Fri Apr  3 23:22:18.414 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 216  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.237 2009  to  Fri Apr  3 23:22:18.302 2009   (  0.06) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 217  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.294 2009  to  Fri Apr  3 23:22:18.348 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 218  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:22:18.302 2009  to  Fri Apr  3 23:22:18.355 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 219  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Apr  3 23:22:18.424 2009  to  Fri Apr  3 23:22:18.424 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 220  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Apr  3 23:23:03.325 2009  to  Fri Apr  3 23:23:03.325 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

 221  SEQERROR  IIF        command.preset.(TRACK)                                        Fri Apr  3 23:23:03.596 2009  to  Fri Apr  3 23:23:03.596 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for both LBC mode TRACK from IIF

 222  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:23:04.161 2009  to  Fri Apr  3 23:23:04.559 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 223  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:23:04.092 2009  to  Fri Apr  3 23:23:04.728 2009   (  0.64) secs
                     IIF MoveFocus command started for left LBC for 3.530000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.000000000000000e-02

 224  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:23:04.213 2009  to  Fri Apr  3 23:23:04.505 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 225  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:25:20.294 2009  to  Fri Apr  3 23:25:21.035 2009   (  0.74) secs
                     IIF MoveFocus command started for right LBC for 7.800000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

 226  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:25:20.360 2009  to  Fri Apr  3 23:25:20.865 2009   (  0.51) secs
                     right PSF SetInstrumentOffsets failed

 227  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:25:20.413 2009  to  Fri Apr  3 23:25:20.791 2009   (  0.38) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 228  FAILED    IIF        command.moveFocus                                             Fri Apr  3 23:27:25.103 2009  to  Fri Apr  3 23:27:25.821 2009   (  0.72) secs
                     IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

 229  FAILED    PSF        command.setInstrumentOffsets                                  Fri Apr  3 23:27:25.228 2009  to  Fri Apr  3 23:27:25.655 2009   (  0.43) secs
                     right PSF SetInstrumentOffsets failed

 230  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Apr  3 23:27:25.283 2009  to  Fri Apr  3 23:27:25.573 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 231  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 23:37:02.322 2009  to  Fri Apr  3 23:37:02.392 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 232  SEQERROR  PCS        telescope.command.stopTracking                                Fri Apr  3 23:37:02.501 2009  to  Fri Apr  3 23:37:02.501 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 233  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 23:37:03.441 2009  to  Fri Apr  3 23:37:03.441 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 234  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Apr  3 23:37:03.471 2009  to  Fri Apr  3 23:37:03.471 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 235  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Apr  3 23:37:40.713 2009  to  Fri Apr  3 23:40:17.423 2009   (156.71) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 236  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.492 2009  to  Fri Apr  3 23:37:41.492 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895482929e+09 but t0 of the AZ target polynomial is 4.745543856409000e+09. Difference= 3.907392883300781e+01 seq=534797

 237  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.493 2009  to  Fri Apr  3 23:37:41.493 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895484084e+09 but t0 of the EL target polynomial is 4.745543856409000e+09. Difference= 3.907508373260498e+01 seq=534797

 238  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Fri Apr  3 23:37:41.494 2009  to  Fri Apr  3 23:37:41.494 2009   (  0.00) secs
                     MJDsec from DSP is 4.745543895409586e+09 but t0 of the LFBG target polynomial is 4.745538706660000e+09. Difference= 5.188749586105347e+03 seq=431845

 239  FAILED    GCS        command.autoAcquireGuidestar                                  Fri Apr  3 23:39:16.844 2009  to  Fri Apr  3 23:40:17.031 2009   ( 60.19) secs
                     guiding was not stable within 6 cycles

 240  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:29:46.871 2009  to  Sat Apr  4 00:29:46.871 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 241  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:29:46.977 2009  to  Sat Apr  4 00:29:46.977 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 242  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:29:46.924 2009  to  Sat Apr  4 00:29:46.924 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 243  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:30:08.230 2009  to  Sat Apr  4 00:30:08.230 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 244  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:30:08.178 2009  to  Sat Apr  4 00:30:08.178 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 245  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:30:08.282 2009  to  Sat Apr  4 00:30:08.282 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 246  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 00:48:26.816 2009  to  Sat Apr  4 00:48:26.816 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 247  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 00:48:26.762 2009  to  Sat Apr  4 00:48:26.762 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 248  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 00:48:26.868 2009  to  Sat Apr  4 00:48:26.868 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 249  SHUTDOWN  PCS        shutdown                                                      Sat Apr  4 01:05:33.274 2009  to  Sat Apr  4 01:05:33.274 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33g

 250  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Apr  4 01:05:34.157 2009  to  Sat Apr  4 01:05:34.157 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 251  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Apr  4 01:05:34.168 2009  to  Sat Apr  4 01:05:34.168 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 252  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sat Apr  4 01:05:35.263 2009  to  Sat Apr  4 01:05:35.263 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 253  FAILED    PMC        cellStatus.telemetryError                                     Sat Apr  4 01:05:36.341 2009  to  Sat Apr  4 01:05:36.341 2009   (  0.00) secs
                     right PMC CellStatus telemetry error: 2006: MySQL server has gone away

 254  SHUTDOWN  PMC        shutdown                                                      Sat Apr  4 01:05:36.394 2009  to  Sat Apr  4 01:05:36.394 2009   (  0.00) secs
                     right PMC subsystem shut down

 255  FAILED    PMC        cellStatus.telemetryError                                     Sat Apr  4 01:05:40.296 2009  to  Sat Apr  4 01:05:40.296 2009   (  0.00) secs
                     left PMC CellStatus telemetry error: 2006: MySQL server has gone away

 256  SHUTDOWN  PMC        shutdown                                                      Sat Apr  4 01:05:40.348 2009  to  Sat Apr  4 01:05:40.348 2009   (  0.00) secs
                     left PMC subsystem shut down

 257  FAILED    ECS        hydraulicBearing.badPMCData                                   Sat Apr  4 01:05:41.709 2009  to  Sat Apr  4 01:05:41.709 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

 258  FAILED    ECS        instrumentCooling.badPMCData                                  Sat Apr  4 01:05:41.656 2009  to  Sat Apr  4 01:05:41.656 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

 259  FAILED    PMC        actuator.telemetryError                                       Sat Apr  4 01:05:50.123 2009  to  Sat Apr  4 01:05:50.123 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 260  STARTUP   PMC        startup                                                       Sat Apr  4 01:05:53.316 2009  to  Sat Apr  4 01:05:53.316 2009   (  0.00) secs
                     left PMC subsystem started, version 4.8

 261  FAILED    PMC        actuator.telemetryError                                       Sat Apr  4 01:06:00.223 2009  to  Sat Apr  4 01:06:00.223 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

 262  STARTUP   PMC        startup                                                       Sat Apr  4 01:06:04.167 2009  to  Sat Apr  4 01:06:04.167 2009   (  0.00) secs
                     right PMC subsystem started, version 4.8

 263  STARTUP   PCS        startup                                                       Sat Apr  4 01:06:07.787 2009  to  Sat Apr  4 01:06:07.787 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33g

 264  FAILED    IIF        command.preset.(ACTIVE)                                       Sat Apr  4 01:07:15.555 2009  to  Sat Apr  4 01:09:51.637 2009   (156.08) secs
                     IIF Preset command wait for telescope started for left IRTC
                     IIF Preset alert for left IRTC mode ACTIVE: Primary mirror collimation reached limit
                     IIF Preset alert for left IRTC mode ACTIVE: adjusted exposure time to 4416 ms
                     IIF Preset alert for left IRTC mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left IRTC mode ACTIVE from IIF

 265  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.331 2009  to  Sat Apr  4 01:07:16.331 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270311828e+09 but t0 of the AZ target polynomial is 4.745549167122000e+09. Difference= 1.031898279190063e+02 seq=640980

 266  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.332 2009  to  Sat Apr  4 01:07:16.332 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270312785e+09 but t0 of the EL target polynomial is 4.745549167122000e+09. Difference= 1.031907854080200e+02 seq=640980

 267  FAILED    MCS.MCSPU  MCSPU.Tracker.timeDisparity                                   Sat Apr  4 01:07:16.333 2009  to  Sat Apr  4 01:07:16.333 2009   (  0.00) secs
                     MJDsec from DSP is 4.745549270287866e+09 but t0 of the LFBG target polynomial is 4.745549167122000e+09. Difference= 1.031658658981323e+02 seq=538027

 268  FAILED    GCS        command.autoAcquireGuidestar                                  Sat Apr  4 01:08:24.922 2009  to  Sat Apr  4 01:09:51.186 2009   ( 86.26) secs
                     guiding was not stable within 6 cycles

 269  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Sat Apr  4 02:04:25.761 2009  to  Sat Apr  4 02:04:25.761 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

 270  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Sat Apr  4 02:04:25.760 2009  to  Sat Apr  4 02:04:25.760 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 271  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:35.014 2009  to  Sat Apr  4 02:04:35.014 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 272  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:39.503 2009  to  Sat Apr  4 02:04:39.503 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 273  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:04:48.070 2009  to  Sat Apr  4 02:04:48.070 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 274  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Sat Apr  4 02:05:34.742 2009  to  Sat Apr  4 02:05:34.742 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 275  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:05:57.228 2009  to  Sat Apr  4 02:05:57.228 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 276  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:06:23.547 2009  to  Sat Apr  4 02:06:23.547 2009   (  0.00) secs
                     StowIdleOut: RT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 277  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:06:56.594 2009  to  Sat Apr  4 02:06:56.594 2009   (  0.00) secs
                     StowIdleOut: LFT StowIdleOut: ignored a stowpin IN command because pin not lined up with hole

 278  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sat Apr  4 02:09:58.670 2009  to  Sat Apr  4 02:09:58.670 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 279  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:12:42.845 2009  to  Sat Apr  4 02:12:42.845 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 280  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:13:13.113 2009  to  Sat Apr  4 02:13:13.113 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 281  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Sat Apr  4 02:13:15.157 2009  to  Sat Apr  4 02:13:15.157 2009   (  0.00) secs
                     A left stowpin command was not queued because queue was full or arguments were bad.

 282  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.cmdRec                                   Sat Apr  4 02:15:11.737 2009  to  Sat Apr  4 02:15:11.737 2009   (  0.00) secs
                     Received a clrreterr command.

 283  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:17:41.653 2009  to  Sat Apr  4 02:17:41.653 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: ignored a stowpin out command because stopwin not lined up

 284  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.commandIgnored                         Sat Apr  4 02:17:54.301 2009  to  Sat Apr  4 02:17:54.301 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: ignored a stowpin out command because stopwin not lined up

 285  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:19:41.287 2009  to  Sat Apr  4 02:19:41.287 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 286  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Sat Apr  4 02:19:45.451 2009  to  Sat Apr  4 02:19:45.451 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 287  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:19:50.801 2009  to  Sat Apr  4 02:19:50.801 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 288  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Sat Apr  4 02:19:56.853 2009  to  Sat Apr  4 02:19:56.853 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

 289  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Sat Apr  4 02:20:19.226 2009  to  Sat Apr  4 02:20:19.226 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 290  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 03:29:21.988 2009  to  Sat Apr  4 03:29:21.988 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 291  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 03:29:22.093 2009  to  Sat Apr  4 03:29:22.093 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 292  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 03:29:22.041 2009  to  Sat Apr  4 03:29:22.041 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 293  FAILED    PMC        VxInterface.packetReadError                                   Sat Apr  4 03:31:23.918 2009  to  Sat Apr  4 03:31:23.918 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 294  FAILED    PMC        VxInterface.selectTimeout                                     Sat Apr  4 03:31:23.866 2009  to  Sat Apr  4 03:31:23.866 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 295  FAILED    PMC        thermal.badReceive                                            Sat Apr  4 03:31:23.971 2009  to  Sat Apr  4 03:31:23.971 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

**********************************************************
    Reporting period ending:   Sat Apr  4 06:33:52.232 2009
********************************************************************************************************
Topic revision: r3 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback