You are here: Foswiki>Software Web>TCSSWReportFile_090330 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 30 2009 to Mar 31 2009
 
    Reporting period beginning:   Mon Mar 30 18:08:07.214 2009
    Reporting period ending:      Tue Mar 31 06:38:59.129 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.07    0.31    0.24    0.47   100.0 %         18         18                      
                                                                       0.07    0.31    0.24    0.47
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .   12.81    9.80    0.00   53.80    50.0 %         18          9          9           
                                                                       9.06    7.26    2.61   31.31
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.00  301.26  301.26  301.27     0.0 %          3                     3               timeout =     3
                                                                                                   
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    0.04    1.35    1.32    1.38     0.0 %          2                     2           
                                                                                                   

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  SEQERROR  IIF        command.moveFocus                                             Mon Mar 30 21:31:56.410 2009  to  Mon Mar 30 21:32:40.698 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02

   2  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:32:40.698 2009  to  Mon Mar 30 21:33:34.500 2009   ( 53.80) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492118936342592e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   3  SEQERROR  IIF        command.moveFocus                                             Mon Mar 30 21:33:45.930 2009  to  Mon Mar 30 21:33:45.930 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   4  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:35:10.289 2009  to  Mon Mar 30 21:35:20.076 2009   (  9.79) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492119109953703e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   5  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:44:32.711 2009  to  Mon Mar 30 21:44:39.417 2009   (  6.71) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492119760416666e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   6  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 30 22:24:20.994 2009  to  Mon Mar 30 22:24:22.318 2009   (  1.32) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492122525462963e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for both LBC mode TRACK from IIF

   7  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:24:23.069 2009  to  Mon Mar 30 22:24:29.872 2009   (  6.80) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

   8  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 30 22:34:48.005 2009  to  Mon Mar 30 22:34:49.388 2009   (  1.38) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123251157408e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for both LBC mode TRACK from IIF

   9  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:34:50.081 2009  to  Mon Mar 30 22:34:56.782 2009   (  6.70) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  10  FAILED    IIF        command.offset                                                Mon Mar 30 22:35:57.655 2009  to  Mon Mar 30 22:40:58.916 2009   (301.26) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123331018518e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  11  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 30 22:35:58.189 2009  to  Mon Mar 30 22:41:23.728 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

  12  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:40:59.367 2009  to  Mon Mar 30 22:41:06.072 2009   (  6.70) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  13  FAILED    IIF        command.offset                                                Mon Mar 30 22:41:23.186 2009  to  Mon Mar 30 22:46:24.455 2009   (301.27) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123708333333e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  14  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 30 22:41:23.728 2009  to  Mon Mar 30 22:46:49.102 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

  15  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:46:24.842 2009  to  Mon Mar 30 22:46:33.674 2009   (  8.83) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  16  FAILED    IIF        command.offset                                                Mon Mar 30 22:46:48.546 2009  to  Mon Mar 30 22:51:49.807 2009   (301.26) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492124084490741e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  17  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:51:50.131 2009  to  Mon Mar 30 22:52:01.839 2009   ( 11.71) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3721                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7442                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     124                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      16                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             6
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       4                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            20
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            10
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      21                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            67
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                            89
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      53                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       5                      
 *** MCSPU.ERPlcDevice.readError. . . . . . . . . . . . . . . . . .               3045           
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  1           
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      60                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 17           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      16                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      48                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       8                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 40           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.SwingArm.lockfailELRIO2Power . . . . . . . . . . . . . .                  8           
     MCSPU.Enclosure.eroff. . . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.Enclosure.erstop . . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.Enclosure.eron . . . . . . . . . . . . . . . . . . . . .                            11
     MCSPU.Enclosure.ergo . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               4672           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Mon Mar 30 18:59:49.172 2009  to  Mon Mar 30 18:59:49.172 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 30 19:01:06.021 2009  to  Mon Mar 30 19:01:06.021 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Mon Mar 30 19:03:21.617 2009  to  Mon Mar 30 19:03:21.617 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   4  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 30 19:03:31.347 2009  to  Mon Mar 30 19:03:31.347 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   5  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:43.118 2009  to  Mon Mar 30 19:35:43.118 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 1 times

   6  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:44.151 2009  to  Mon Mar 30 19:35:44.151 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 2 times

   7  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:45.195 2009  to  Mon Mar 30 19:35:45.195 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 3 times

   8  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:46.227 2009  to  Mon Mar 30 19:35:46.227 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 4 times

   9  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:47.266 2009  to  Mon Mar 30 19:35:47.266 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 5 times

  10  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:48.315 2009  to  Mon Mar 30 19:35:48.315 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 6 times

  11  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:49.361 2009  to  Mon Mar 30 19:35:49.361 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 7 times

  12  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:50.397 2009  to  Mon Mar 30 19:35:50.397 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 8 times

  13  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:51.442 2009  to  Mon Mar 30 19:35:51.442 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 9 times

  14  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:52.478 2009  to  Mon Mar 30 19:35:52.478 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 10 times

  15  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:53.511 2009  to  Mon Mar 30 19:35:53.511 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 11 times

  16  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:54.556 2009  to  Mon Mar 30 19:35:54.556 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 12 times

  17  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:55.591 2009  to  Mon Mar 30 19:35:55.591 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 13 times

  18  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:56.620 2009  to  Mon Mar 30 19:35:56.620 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 14 times

  19  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:57.657 2009  to  Mon Mar 30 19:35:57.657 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 15 times

  20  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:58.701 2009  to  Mon Mar 30 19:35:58.701 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 16 times

  21  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:59.742 2009  to  Mon Mar 30 19:35:59.742 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 17 times

  22  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:00.790 2009  to  Mon Mar 30 19:36:00.790 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 18 times

  23  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:01.835 2009  to  Mon Mar 30 19:36:01.835 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 19 times

  24  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:02.878 2009  to  Mon Mar 30 19:36:02.878 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 20 times

  25  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:03.910 2009  to  Mon Mar 30 19:36:03.910 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 21 times

  26  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:04.952 2009  to  Mon Mar 30 19:36:04.952 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 22 times

  27  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:05.985 2009  to  Mon Mar 30 19:36:05.985 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 23 times

  28  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:07.031 2009  to  Mon Mar 30 19:36:07.031 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 24 times

  29  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:08.067 2009  to  Mon Mar 30 19:36:08.067 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 25 times

  30  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Mon Mar 30 19:46:49.738 2009  to  Mon Mar 30 19:46:49.738 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Mon Mar 30 19:46:51.740 2009  to  Mon Mar 30 19:46:51.740 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 19:47:38.909 2009  to  Mon Mar 30 19:47:38.909 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 19:47:38.916 2009  to  Mon Mar 30 19:47:38.916 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  34  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 19:47:39.014 2009  to  Mon Mar 30 19:47:39.014 2009   (  0.00) secs
                     drive cabinet has turned on.

  35  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.023 2009  to  Mon Mar 30 19:47:40.023 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.023 2009  to  Mon Mar 30 19:47:40.023 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  37  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.024 2009  to  Mon Mar 30 19:47:40.024 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.024 2009  to  Mon Mar 30 19:47:40.024 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.025 2009  to  Mon Mar 30 19:47:40.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.025 2009  to  Mon Mar 30 19:47:40.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.026 2009  to  Mon Mar 30 19:47:40.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  42  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.026 2009  to  Mon Mar 30 19:47:40.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 20:49:33.845 2009  to  Mon Mar 30 20:49:33.845 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 20:49:33.850 2009  to  Mon Mar 30 20:49:33.850 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 20:49:33.942 2009  to  Mon Mar 30 20:49:33.942 2009   (  0.00) secs
                     drive cabinet has turned on.

  46  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  47  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.952 2009  to  Mon Mar 30 20:49:34.952 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  51  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  52  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  53  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.954 2009  to  Mon Mar 30 20:49:34.954 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  54  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.968 2009  to  Mon Mar 30 21:01:13.968 2009   (  0.00) secs
                     Left PF is locked out by power being off in ELRIO rack 2.

  55  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.969 2009  to  Mon Mar 30 21:01:13.969 2009   (  0.00) secs
                     Left M2 is locked out by power being off in ELRIO rack 2.

  56  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.969 2009  to  Mon Mar 30 21:01:13.969 2009   (  0.00) secs
                     Left M3 is locked out by power being off in ELRIO rack 2.

  57  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Left MC is locked out by power being off in ELRIO rack 2.

  58  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Right PF is locked out by power being off in ELRIO rack 2.

  59  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Right M2 is locked out by power being off in ELRIO rack 2.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.971 2009  to  Mon Mar 30 21:01:13.971 2009   (  0.00) secs
                     Right M3 is locked out by power being off in ELRIO rack 2.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.971 2009  to  Mon Mar 30 21:01:13.971 2009   (  0.00) secs
                     Right MC is locked out by power being off in ELRIO rack 2.

  62  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.965 2009  to  Mon Mar 30 21:02:20.965 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  63  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.965 2009  to  Mon Mar 30 21:02:20.965 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  64  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.967 2009  to  Mon Mar 30 21:02:20.967 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.967 2009  to  Mon Mar 30 21:02:20.967 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.969 2009  to  Mon Mar 30 21:02:20.969 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 21:34:31.960 2009  to  Mon Mar 30 21:34:31.960 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  71  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 21:34:31.963 2009  to  Mon Mar 30 21:34:31.963 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  72  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 21:34:32.057 2009  to  Mon Mar 30 21:34:32.057 2009   (  0.00) secs
                     drive cabinet has turned on.

  73  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:34:33.073 2009  to  Mon Mar 30 21:34:33.073 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 23:47:18.291 2009  to  Mon Mar 30 23:47:18.291 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 23:47:18.297 2009  to  Mon Mar 30 23:47:18.297 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  76  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 23:47:18.396 2009  to  Mon Mar 30 23:47:18.396 2009   (  0.00) secs
                     drive cabinet has turned on.

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:40.271 2009  to  Tue Mar 31 02:14:40.271 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly: EL = -1.531318e-03 rad. Too low.

  78  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:14:41.224 2009  to  Tue Mar 31 02:14:41.224 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  79  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:43.317 2009  to  Tue Mar 31 02:14:43.317 2009   (  0.00) secs
                     EL bad poly no. 62: BAD Poly: EL = -9.797888e-02 rad. Too low.

  80  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:46.319 2009  to  Tue Mar 31 02:14:46.319 2009   (  0.00) secs
                     EL bad poly no. 122: BAD Poly: EL = -1.922620e-01 rad. Too low.

  81  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:22.538 2009  to  Tue Mar 31 02:17:22.538 2009   (  0.00) secs
                     EL bad poly no. 126: BAD Poly: EL = -8.010463e-03 rad. Too low.

  82  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:17:23.532 2009  to  Tue Mar 31 02:17:23.532 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:25.590 2009  to  Tue Mar 31 02:17:25.590 2009   (  0.00) secs
                     EL bad poly no. 187: BAD Poly: EL = -9.552354e-02 rad. Too low.

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:28.645 2009  to  Tue Mar 31 02:17:28.645 2009   (  0.00) secs
                     EL bad poly no. 248: BAD Poly: EL = -3.931341e-01 rad. Too low.

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:18:31.169 2009  to  Tue Mar 31 02:18:31.169 2009   (  0.00) secs
                     EL bad poly no. 250: BAD Poly: EL = -1.761124e-01 rad. Too low.

  86  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:18:32.131 2009  to  Tue Mar 31 02:18:32.131 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:38.117 2009  to  Tue Mar 31 02:20:38.117 2009   (  0.00) secs
                     EL bad poly no. 292: BAD Poly: EL = -1.680639e-02 rad. Too low.

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:20:39.075 2009  to  Tue Mar 31 02:20:39.075 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:41.164 2009  to  Tue Mar 31 02:20:41.164 2009   (  0.00) secs
                     EL bad poly no. 353: BAD Poly: EL = -9.403850e-02 rad. Too low.

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:44.216 2009  to  Tue Mar 31 02:20:44.216 2009   (  0.00) secs
                     EL bad poly no. 414: BAD Poly: EL = -3.720931e-01 rad. Too low.

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:50.571 2009  to  Tue Mar 31 02:20:50.571 2009   (  0.00) secs
                     EL bad poly no. 417: BAD Poly: EL = -7.057742e-02 rad. Too low.

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:20:51.554 2009  to  Tue Mar 31 02:20:51.554 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  93  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:23:51.555 2009  to  Tue Mar 31 02:23:51.555 2009   (  0.00) secs
                     EL bad poly no. 459: BAD Poly: EL = -8.770329e-02 rad. Too low.

  94  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:23:52.532 2009  to  Tue Mar 31 02:23:52.532 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:23:54.610 2009  to  Tue Mar 31 02:23:54.610 2009   (  0.00) secs
                     EL bad poly no. 520: BAD Poly: EL = -3.505208e-01 rad. Too low.

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:24:37.319 2009  to  Tue Mar 31 02:24:37.319 2009   (  0.00) secs
                     EL bad poly no. 542: BAD Poly: EL = -6.245784e-04 rad. Too low.

  97  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:24:38.293 2009  to  Tue Mar 31 02:24:38.293 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  98  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:24:40.322 2009  to  Tue Mar 31 02:24:40.322 2009   (  0.00) secs
                     EL bad poly no. 602: BAD Poly: EL = -9.358626e-03 rad. Too low.

  99  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:44.898 2009  to  Tue Mar 31 02:28:44.898 2009   (  0.00) secs
                     EL bad poly no. 625: BAD Poly: EL = -8.003483e-02 rad. Too low.

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:28:45.881 2009  to  Tue Mar 31 02:28:45.881 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:47.948 2009  to  Tue Mar 31 02:28:47.948 2009   (  0.00) secs
                     EL bad poly no. 686: BAD Poly: EL = -1.684111e-02 rad. Too low.

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:51.000 2009  to  Tue Mar 31 02:28:51.000 2009   (  0.00) secs
                     EL bad poly no. 747: BAD Poly: EL = -7.107865e-03 rad. Too low.

 103  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:54.027 2009  to  Tue Mar 31 02:28:54.027 2009   (  0.00) secs
                     EL bad poly no. 804: BAD Poly: EL = -3.557116e-03 rad. Too low.

 104  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:57.042 2009  to  Tue Mar 31 02:28:57.042 2009   (  0.00) secs
                     EL bad poly no. 855: BAD Poly: EL = -1.281188e-02 rad. Too low.

 105  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:02.387 2009  to  Tue Mar 31 02:44:02.387 2009   (  0.00) secs
                     EL bad poly no. 861: BAD Poly: EL = -9.304027e-04 rad. Too low.

 106  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:44:03.348 2009  to  Tue Mar 31 02:44:03.348 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 107  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:05.389 2009  to  Tue Mar 31 02:44:05.389 2009   (  0.00) secs
                     EL bad poly no. 921: BAD Poly: EL = -6.349880e-02 rad. Too low.

 108  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:08.440 2009  to  Tue Mar 31 02:44:08.440 2009   (  0.00) secs
                     EL bad poly no. 978: BAD Poly: EL = -3.710378e-03 rad. Too low.

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:11.442 2009  to  Tue Mar 31 02:44:11.442 2009   (  0.00) secs
                     EL bad poly no. 1029: BAD Poly: EL = -6.082026e-03 rad. Too low.

 110  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:14.466 2009  to  Tue Mar 31 02:44:14.466 2009   (  0.00) secs
                     EL bad poly no. 1083: BAD Poly: EL = -1.611520e-02 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.01    0.12    0.11    0.13   100.0 %         18         18                      
                                                                       0.01    0.12    0.11    0.13
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.00    0.27    0.27    0.28   100.0 %          3          3                      
                                                                       0.00    0.27    0.27    0.28
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.09    0.12    0.06    0.19   100.0 %          2          2                      
                                                                       0.09    0.12    0.06    0.19
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.17    0.44    0.32    0.56     0.0 %          2                     2           
                                                                                                   

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  FAILED    PCS        telescope.command.startTracking                               Mon Mar 30 22:24:21.729 2009  to  Mon Mar 30 22:24:22.046 2009   (  0.32) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

   2  FAILED    PCS        telescope.command.startTracking                               Mon Mar 30 22:34:48.706 2009  to  Mon Mar 30 22:34:49.269 2009   (  0.56) secs
                     PCS starting get rotator trajectory
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   22.12   12.24    2.06   97.24    50.0 %         18          9          9           
                                                                       8.85    6.62    2.06   30.11

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      10                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      10                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                         32739
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                         32739
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            20
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             1
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 30 19:04:35.003 2009  to  Mon Mar 30 19:04:35.003 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   2  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 30 19:04:34.948 2009  to  Mon Mar 30 19:04:34.948 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   3  FAILED    PMC        thermal.badReceive                                            Mon Mar 30 19:04:35.056 2009  to  Mon Mar 30 19:04:35.056 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:31:56.856 2009  to  Mon Mar 30 21:33:34.097 2009   ( 97.24) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:33:34.452 2009  to  Mon Mar 30 21:33:45.525 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:35:10.603 2009  to  Mon Mar 30 21:35:19.672 2009   (  9.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:44:32.950 2009  to  Mon Mar 30 21:44:39.013 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:24:23.349 2009  to  Mon Mar 30 22:24:29.412 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 30 22:24:26.199 2009  to  Mon Mar 30 22:24:26.199 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.close                                             Mon Mar 30 22:24:26.257 2009  to  Mon Mar 30 22:24:26.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:34:50.314 2009  to  Mon Mar 30 22:34:56.376 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:40:59.603 2009  to  Mon Mar 30 22:41:05.667 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:46:25.204 2009  to  Mon Mar 30 22:46:33.272 2009   (  8.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:51:50.369 2009  to  Mon Mar 30 22:52:01.444 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          4          4                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .   12.76    9.54    0.00   53.52    50.0 %         18          9          9           
                                                                       8.95    7.02    2.41   30.77
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   22.14   12.39    2.19   97.44    50.0 %         18          9          9           
                                                                       8.89    6.78    2.19   30.36
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .   22.14   12.51    2.30   97.55    50.0 %         18          9          9           
                                                                       8.92    6.89    2.30   30.57

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:31:56.673 2009  to  Mon Mar 30 21:33:34.225 2009   ( 97.55) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   2  SEQERROR  PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:31:56.621 2009  to  Mon Mar 30 21:32:40.764 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:31:56.727 2009  to  Mon Mar 30 21:33:34.167 2009   ( 97.44) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   4  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:32:40.764 2009  to  Mon Mar 30 21:33:34.281 2009   ( 53.52) secs
                     right PSF SetInstrumentOffsets failed

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:33:34.388 2009  to  Mon Mar 30 21:33:45.592 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   6  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:33:34.334 2009  to  Mon Mar 30 21:33:45.651 2009   ( 11.32) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   7  SEQERROR  PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:33:45.709 2009  to  Mon Mar 30 21:33:45.709 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF SetInstrumentOffsets failed

   8  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:35:10.433 2009  to  Mon Mar 30 21:35:19.855 2009   (  9.42) secs
                     right PSF SetInstrumentOffsets failed

   9  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:35:10.537 2009  to  Mon Mar 30 21:35:19.741 2009   (  9.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  10  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:35:10.485 2009  to  Mon Mar 30 21:35:19.799 2009   (  9.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  11  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:44:32.779 2009  to  Mon Mar 30 21:44:39.193 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  12  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:44:32.832 2009  to  Mon Mar 30 21:44:39.137 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:44:32.886 2009  to  Mon Mar 30 21:44:39.080 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  14  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:24:23.133 2009  to  Mon Mar 30 22:24:29.593 2009   (  6.46) secs
                     right PSF SetInstrumentOffsets failed

  15  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:24:23.186 2009  to  Mon Mar 30 22:24:29.538 2009   (  6.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:24:23.239 2009  to  Mon Mar 30 22:24:29.482 2009   (  6.24) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  17  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:34:50.143 2009  to  Mon Mar 30 22:34:56.556 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  18  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:34:50.197 2009  to  Mon Mar 30 22:34:56.500 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  19  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:34:50.250 2009  to  Mon Mar 30 22:34:56.444 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  20  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:40:59.432 2009  to  Mon Mar 30 22:41:05.848 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:40:59.540 2009  to  Mon Mar 30 22:41:05.735 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  22  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:40:59.487 2009  to  Mon Mar 30 22:41:05.792 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  23  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:46:25.033 2009  to  Mon Mar 30 22:46:33.452 2009   (  8.42) secs
                     right PSF SetInstrumentOffsets failed

  24  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:46:25.087 2009  to  Mon Mar 30 22:46:33.396 2009   (  8.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  25  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:46:25.139 2009  to  Mon Mar 30 22:46:33.340 2009   (  8.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  26  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:51:50.198 2009  to  Mon Mar 30 22:52:01.617 2009   ( 11.42) secs
                     right PSF SetInstrumentOffsets failed

  27  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:51:50.305 2009  to  Mon Mar 30 22:52:01.507 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  28  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:51:50.252 2009  to  Mon Mar 30 22:52:01.562 2009   ( 11.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Mon Mar 30 18:59:49.172 2009  to  Mon Mar 30 18:59:49.172 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 30 19:01:06.021 2009  to  Mon Mar 30 19:01:06.021 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Mon Mar 30 19:03:21.617 2009  to  Mon Mar 30 19:03:21.617 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   4  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 30 19:03:31.347 2009  to  Mon Mar 30 19:03:31.347 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

   5  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 30 19:04:35.003 2009  to  Mon Mar 30 19:04:35.003 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   6  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 30 19:04:34.948 2009  to  Mon Mar 30 19:04:34.948 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   7  FAILED    PMC        thermal.badReceive                                            Mon Mar 30 19:04:35.056 2009  to  Mon Mar 30 19:04:35.056 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   8  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:43.118 2009  to  Mon Mar 30 19:35:43.118 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 1 times

   9  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:44.151 2009  to  Mon Mar 30 19:35:44.151 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 2 times

  10  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:45.195 2009  to  Mon Mar 30 19:35:45.195 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 3 times

  11  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:46.227 2009  to  Mon Mar 30 19:35:46.227 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 4 times

  12  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:47.266 2009  to  Mon Mar 30 19:35:47.266 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 5 times

  13  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:48.315 2009  to  Mon Mar 30 19:35:48.315 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 6 times

  14  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:49.361 2009  to  Mon Mar 30 19:35:49.361 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 7 times

  15  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:50.397 2009  to  Mon Mar 30 19:35:50.397 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 8 times

  16  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:51.442 2009  to  Mon Mar 30 19:35:51.442 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 9 times

  17  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:52.478 2009  to  Mon Mar 30 19:35:52.478 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 10 times

  18  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:53.511 2009  to  Mon Mar 30 19:35:53.511 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 11 times

  19  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:54.556 2009  to  Mon Mar 30 19:35:54.556 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 12 times

  20  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:55.591 2009  to  Mon Mar 30 19:35:55.591 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 13 times

  21  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:56.620 2009  to  Mon Mar 30 19:35:56.620 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 14 times

  22  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:57.657 2009  to  Mon Mar 30 19:35:57.657 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 15 times

  23  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:58.701 2009  to  Mon Mar 30 19:35:58.701 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 16 times

  24  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:35:59.742 2009  to  Mon Mar 30 19:35:59.742 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 17 times

  25  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:00.790 2009  to  Mon Mar 30 19:36:00.790 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 18 times

  26  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:01.835 2009  to  Mon Mar 30 19:36:01.835 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 19 times

  27  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:02.878 2009  to  Mon Mar 30 19:36:02.878 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 20 times

  28  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:03.910 2009  to  Mon Mar 30 19:36:03.910 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 21 times

  29  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:04.952 2009  to  Mon Mar 30 19:36:04.952 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 22 times

  30  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:05.985 2009  to  Mon Mar 30 19:36:05.985 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 23 times

  31  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:07.031 2009  to  Mon Mar 30 19:36:07.031 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 24 times

  32  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Mon Mar 30 19:36:08.067 2009  to  Mon Mar 30 19:36:08.067 2009   (  0.00) secs
                     ERPLC read produced an error (bad read size) 25 times

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Mon Mar 30 19:46:49.738 2009  to  Mon Mar 30 19:46:49.738 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Mon Mar 30 19:46:51.740 2009  to  Mon Mar 30 19:46:51.740 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 19:47:38.909 2009  to  Mon Mar 30 19:47:38.909 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 19:47:38.916 2009  to  Mon Mar 30 19:47:38.916 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 19:47:39.014 2009  to  Mon Mar 30 19:47:39.014 2009   (  0.00) secs
                     drive cabinet has turned on.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.023 2009  to  Mon Mar 30 19:47:40.023 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.023 2009  to  Mon Mar 30 19:47:40.023 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.024 2009  to  Mon Mar 30 19:47:40.024 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.024 2009  to  Mon Mar 30 19:47:40.024 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  42  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.025 2009  to  Mon Mar 30 19:47:40.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.025 2009  to  Mon Mar 30 19:47:40.025 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.026 2009  to  Mon Mar 30 19:47:40.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 19:47:40.026 2009  to  Mon Mar 30 19:47:40.026 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 20:49:33.845 2009  to  Mon Mar 30 20:49:33.845 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 20:49:33.850 2009  to  Mon Mar 30 20:49:33.850 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  48  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 20:49:33.942 2009  to  Mon Mar 30 20:49:33.942 2009   (  0.00) secs
                     drive cabinet has turned on.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  51  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.951 2009  to  Mon Mar 30 20:49:34.951 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  52  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.952 2009  to  Mon Mar 30 20:49:34.952 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  53  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  54  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  55  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.953 2009  to  Mon Mar 30 20:49:34.953 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  56  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 20:49:34.954 2009  to  Mon Mar 30 20:49:34.954 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  57  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.968 2009  to  Mon Mar 30 21:01:13.968 2009   (  0.00) secs
                     Left PF is locked out by power being off in ELRIO rack 2.

  58  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.969 2009  to  Mon Mar 30 21:01:13.969 2009   (  0.00) secs
                     Left M2 is locked out by power being off in ELRIO rack 2.

  59  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.969 2009  to  Mon Mar 30 21:01:13.969 2009   (  0.00) secs
                     Left M3 is locked out by power being off in ELRIO rack 2.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Left MC is locked out by power being off in ELRIO rack 2.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Right PF is locked out by power being off in ELRIO rack 2.

  62  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.970 2009  to  Mon Mar 30 21:01:13.970 2009   (  0.00) secs
                     Right M2 is locked out by power being off in ELRIO rack 2.

  63  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.971 2009  to  Mon Mar 30 21:01:13.971 2009   (  0.00) secs
                     Right M3 is locked out by power being off in ELRIO rack 2.

  64  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockfailELRIO2Power                            Mon Mar 30 21:01:13.971 2009  to  Mon Mar 30 21:01:13.971 2009   (  0.00) secs
                     Right MC is locked out by power being off in ELRIO rack 2.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.965 2009  to  Mon Mar 30 21:02:20.965 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.965 2009  to  Mon Mar 30 21:02:20.965 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.966 2009  to  Mon Mar 30 21:02:20.966 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.967 2009  to  Mon Mar 30 21:02:20.967 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.967 2009  to  Mon Mar 30 21:02:20.967 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:02:20.969 2009  to  Mon Mar 30 21:02:20.969 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  SEQERROR  IIF        command.moveFocus                                             Mon Mar 30 21:31:56.410 2009  to  Mon Mar 30 21:32:40.698 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02

  74  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:31:56.673 2009  to  Mon Mar 30 21:33:34.225 2009   ( 97.55) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  75  SEQERROR  PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:31:56.621 2009  to  Mon Mar 30 21:32:40.764 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetInstrumentOffsets started

  76  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:31:56.727 2009  to  Mon Mar 30 21:33:34.167 2009   ( 97.44) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  77  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:31:56.856 2009  to  Mon Mar 30 21:33:34.097 2009   ( 97.24) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:32:40.698 2009  to  Mon Mar 30 21:33:34.500 2009   ( 53.80) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492118936342592e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  79  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:32:40.764 2009  to  Mon Mar 30 21:33:34.281 2009   ( 53.52) secs
                     right PSF SetInstrumentOffsets failed

  80  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:33:34.388 2009  to  Mon Mar 30 21:33:45.592 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  81  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:33:34.334 2009  to  Mon Mar 30 21:33:45.651 2009   ( 11.32) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  82  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:33:34.452 2009  to  Mon Mar 30 21:33:45.525 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  SEQERROR  PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:33:45.709 2009  to  Mon Mar 30 21:33:45.709 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF SetInstrumentOffsets failed

  84  SEQERROR  IIF        command.moveFocus                                             Mon Mar 30 21:33:45.930 2009  to  Mon Mar 30 21:33:45.930 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 21:34:31.960 2009  to  Mon Mar 30 21:34:31.960 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  86  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 21:34:31.963 2009  to  Mon Mar 30 21:34:31.963 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  87  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 21:34:32.057 2009  to  Mon Mar 30 21:34:32.057 2009   (  0.00) secs
                     drive cabinet has turned on.

  88  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 30 21:34:33.073 2009  to  Mon Mar 30 21:34:33.073 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  89  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:35:10.289 2009  to  Mon Mar 30 21:35:20.076 2009   (  9.79) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492119109953703e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  90  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:35:10.433 2009  to  Mon Mar 30 21:35:19.855 2009   (  9.42) secs
                     right PSF SetInstrumentOffsets failed

  91  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:35:10.537 2009  to  Mon Mar 30 21:35:19.741 2009   (  9.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  92  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:35:10.485 2009  to  Mon Mar 30 21:35:19.799 2009   (  9.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  93  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:35:10.603 2009  to  Mon Mar 30 21:35:19.672 2009   (  9.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  94  FAILED    IIF        command.moveFocus                                             Mon Mar 30 21:44:32.711 2009  to  Mon Mar 30 21:44:39.417 2009   (  6.71) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492119760416666e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  95  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 21:44:32.779 2009  to  Mon Mar 30 21:44:39.193 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  96  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 21:44:32.832 2009  to  Mon Mar 30 21:44:39.137 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  97  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 21:44:32.886 2009  to  Mon Mar 30 21:44:39.080 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  98  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 21:44:32.950 2009  to  Mon Mar 30 21:44:39.013 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  99  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 30 22:24:20.994 2009  to  Mon Mar 30 22:24:22.318 2009   (  1.32) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492122525462963e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for both LBC mode TRACK from IIF

 100  FAILED    PCS        telescope.command.startTracking                               Mon Mar 30 22:24:21.729 2009  to  Mon Mar 30 22:24:22.046 2009   (  0.32) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

 101  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:24:23.069 2009  to  Mon Mar 30 22:24:29.872 2009   (  6.80) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 102  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:24:23.133 2009  to  Mon Mar 30 22:24:29.593 2009   (  6.46) secs
                     right PSF SetInstrumentOffsets failed

 103  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:24:23.186 2009  to  Mon Mar 30 22:24:29.538 2009   (  6.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 104  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:24:23.239 2009  to  Mon Mar 30 22:24:29.482 2009   (  6.24) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 105  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:24:23.349 2009  to  Mon Mar 30 22:24:29.412 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 106  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 30 22:24:26.199 2009  to  Mon Mar 30 22:24:26.199 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 107  FAILED    PMC        VxInterface.close                                             Mon Mar 30 22:24:26.257 2009  to  Mon Mar 30 22:24:26.257 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 108  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 30 22:34:48.005 2009  to  Mon Mar 30 22:34:49.388 2009   (  1.38) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123251157408e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.
                     IIF Preset command failed for both LBC mode TRACK from IIF

 109  FAILED    PCS        telescope.command.startTracking                               Mon Mar 30 22:34:48.706 2009  to  Mon Mar 30 22:34:49.269 2009   (  0.56) secs
                     PCS starting get rotator trajectory
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

 110  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:34:50.081 2009  to  Mon Mar 30 22:34:56.782 2009   (  6.70) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 111  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:34:50.143 2009  to  Mon Mar 30 22:34:56.556 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 112  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:34:50.197 2009  to  Mon Mar 30 22:34:56.500 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 113  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:34:50.250 2009  to  Mon Mar 30 22:34:56.444 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 114  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:34:50.314 2009  to  Mon Mar 30 22:34:56.376 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 115  FAILED    IIF        command.offset                                                Mon Mar 30 22:35:57.655 2009  to  Mon Mar 30 22:40:58.916 2009   (301.26) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123331018518e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

 116  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 30 22:35:58.189 2009  to  Mon Mar 30 22:41:23.728 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 117  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:40:59.367 2009  to  Mon Mar 30 22:41:06.072 2009   (  6.70) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 118  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:40:59.432 2009  to  Mon Mar 30 22:41:05.848 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

 119  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:40:59.540 2009  to  Mon Mar 30 22:41:05.735 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 120  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:40:59.487 2009  to  Mon Mar 30 22:41:05.792 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 121  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:40:59.603 2009  to  Mon Mar 30 22:41:05.667 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 122  FAILED    IIF        command.offset                                                Mon Mar 30 22:41:23.186 2009  to  Mon Mar 30 22:46:24.455 2009   (301.27) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492123708333333e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

 123  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 30 22:41:23.728 2009  to  Mon Mar 30 22:46:49.102 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 124  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:46:24.842 2009  to  Mon Mar 30 22:46:33.674 2009   (  8.83) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 125  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:46:25.033 2009  to  Mon Mar 30 22:46:33.452 2009   (  8.42) secs
                     right PSF SetInstrumentOffsets failed

 126  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:46:25.087 2009  to  Mon Mar 30 22:46:33.396 2009   (  8.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 127  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:46:25.204 2009  to  Mon Mar 30 22:46:33.272 2009   (  8.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 128  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:46:25.139 2009  to  Mon Mar 30 22:46:33.340 2009   (  8.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 129  FAILED    IIF        command.offset                                                Mon Mar 30 22:46:48.546 2009  to  Mon Mar 30 22:51:49.807 2009   (301.26) secs
                     IIF GetTrajectory command started for both LBC, start time 5.492124084490741e+04, time 3.453000000000000e+02, interval 1.000000000000000e+00
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

 130  FAILED    IIF        command.moveFocus                                             Mon Mar 30 22:51:50.131 2009  to  Mon Mar 30 22:52:01.839 2009   ( 11.71) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 131  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 30 22:51:50.198 2009  to  Mon Mar 30 22:52:01.617 2009   ( 11.42) secs
                     right PSF SetInstrumentOffsets failed

 132  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 30 22:51:50.305 2009  to  Mon Mar 30 22:52:01.507 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 133  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 30 22:51:50.252 2009  to  Mon Mar 30 22:52:01.562 2009   ( 11.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 134  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 30 22:51:50.369 2009  to  Mon Mar 30 22:52:01.444 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 135  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 23:47:18.291 2009  to  Mon Mar 30 23:47:18.291 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 136  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 30 23:47:18.297 2009  to  Mon Mar 30 23:47:18.297 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 137  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 30 23:47:18.396 2009  to  Mon Mar 30 23:47:18.396 2009   (  0.00) secs
                     drive cabinet has turned on.

 138  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:40.271 2009  to  Tue Mar 31 02:14:40.271 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly: EL = -1.531318e-03 rad. Too low.

 139  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:14:41.224 2009  to  Tue Mar 31 02:14:41.224 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 140  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:43.317 2009  to  Tue Mar 31 02:14:43.317 2009   (  0.00) secs
                     EL bad poly no. 62: BAD Poly: EL = -9.797888e-02 rad. Too low.

 141  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:14:46.319 2009  to  Tue Mar 31 02:14:46.319 2009   (  0.00) secs
                     EL bad poly no. 122: BAD Poly: EL = -1.922620e-01 rad. Too low.

 142  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:22.538 2009  to  Tue Mar 31 02:17:22.538 2009   (  0.00) secs
                     EL bad poly no. 126: BAD Poly: EL = -8.010463e-03 rad. Too low.

 143  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:17:23.532 2009  to  Tue Mar 31 02:17:23.532 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 144  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:25.590 2009  to  Tue Mar 31 02:17:25.590 2009   (  0.00) secs
                     EL bad poly no. 187: BAD Poly: EL = -9.552354e-02 rad. Too low.

 145  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:17:28.645 2009  to  Tue Mar 31 02:17:28.645 2009   (  0.00) secs
                     EL bad poly no. 248: BAD Poly: EL = -3.931341e-01 rad. Too low.

 146  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:18:31.169 2009  to  Tue Mar 31 02:18:31.169 2009   (  0.00) secs
                     EL bad poly no. 250: BAD Poly: EL = -1.761124e-01 rad. Too low.

 147  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:18:32.131 2009  to  Tue Mar 31 02:18:32.131 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 148  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:38.117 2009  to  Tue Mar 31 02:20:38.117 2009   (  0.00) secs
                     EL bad poly no. 292: BAD Poly: EL = -1.680639e-02 rad. Too low.

 149  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:20:39.075 2009  to  Tue Mar 31 02:20:39.075 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 150  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:41.164 2009  to  Tue Mar 31 02:20:41.164 2009   (  0.00) secs
                     EL bad poly no. 353: BAD Poly: EL = -9.403850e-02 rad. Too low.

 151  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:44.216 2009  to  Tue Mar 31 02:20:44.216 2009   (  0.00) secs
                     EL bad poly no. 414: BAD Poly: EL = -3.720931e-01 rad. Too low.

 152  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:20:50.571 2009  to  Tue Mar 31 02:20:50.571 2009   (  0.00) secs
                     EL bad poly no. 417: BAD Poly: EL = -7.057742e-02 rad. Too low.

 153  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:20:51.554 2009  to  Tue Mar 31 02:20:51.554 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 154  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:23:51.555 2009  to  Tue Mar 31 02:23:51.555 2009   (  0.00) secs
                     EL bad poly no. 459: BAD Poly: EL = -8.770329e-02 rad. Too low.

 155  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:23:52.532 2009  to  Tue Mar 31 02:23:52.532 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 156  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:23:54.610 2009  to  Tue Mar 31 02:23:54.610 2009   (  0.00) secs
                     EL bad poly no. 520: BAD Poly: EL = -3.505208e-01 rad. Too low.

 157  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:24:37.319 2009  to  Tue Mar 31 02:24:37.319 2009   (  0.00) secs
                     EL bad poly no. 542: BAD Poly: EL = -6.245784e-04 rad. Too low.

 158  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:24:38.293 2009  to  Tue Mar 31 02:24:38.293 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 159  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:24:40.322 2009  to  Tue Mar 31 02:24:40.322 2009   (  0.00) secs
                     EL bad poly no. 602: BAD Poly: EL = -9.358626e-03 rad. Too low.

 160  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:44.898 2009  to  Tue Mar 31 02:28:44.898 2009   (  0.00) secs
                     EL bad poly no. 625: BAD Poly: EL = -8.003483e-02 rad. Too low.

 161  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:28:45.881 2009  to  Tue Mar 31 02:28:45.881 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 162  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:47.948 2009  to  Tue Mar 31 02:28:47.948 2009   (  0.00) secs
                     EL bad poly no. 686: BAD Poly: EL = -1.684111e-02 rad. Too low.

 163  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:51.000 2009  to  Tue Mar 31 02:28:51.000 2009   (  0.00) secs
                     EL bad poly no. 747: BAD Poly: EL = -7.107865e-03 rad. Too low.

 164  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:54.027 2009  to  Tue Mar 31 02:28:54.027 2009   (  0.00) secs
                     EL bad poly no. 804: BAD Poly: EL = -3.557116e-03 rad. Too low.

 165  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:28:57.042 2009  to  Tue Mar 31 02:28:57.042 2009   (  0.00) secs
                     EL bad poly no. 855: BAD Poly: EL = -1.281188e-02 rad. Too low.

 166  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:02.387 2009  to  Tue Mar 31 02:44:02.387 2009   (  0.00) secs
                     EL bad poly no. 861: BAD Poly: EL = -9.304027e-04 rad. Too low.

 167  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 31 02:44:03.348 2009  to  Tue Mar 31 02:44:03.348 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 168  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:05.389 2009  to  Tue Mar 31 02:44:05.389 2009   (  0.00) secs
                     EL bad poly no. 921: BAD Poly: EL = -6.349880e-02 rad. Too low.

 169  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:08.440 2009  to  Tue Mar 31 02:44:08.440 2009   (  0.00) secs
                     EL bad poly no. 978: BAD Poly: EL = -3.710378e-03 rad. Too low.

 170  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:11.442 2009  to  Tue Mar 31 02:44:11.442 2009   (  0.00) secs
                     EL bad poly no. 1029: BAD Poly: EL = -6.082026e-03 rad. Too low.

 171  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 31 02:44:14.466 2009  to  Tue Mar 31 02:44:14.466 2009   (  0.00) secs
                     EL bad poly no. 1083: BAD Poly: EL = -1.611520e-02 rad. Too low.

**********************************************************
    Reporting period ending:   Tue Mar 31 06:38:59.129 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback