You are here: Foswiki>Software Web>TCSSWReportFile_090329 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 29 2009 to Mar 30 2009
 
    Reporting period beginning:   Sun Mar 29 18:07:01.750 2009
    Reporting period ending:      Mon Mar 30 06:39:53.396 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.01    0.31    0.31    0.32   100.0 %          2          2                      
                                                                       0.01    0.31    0.31    0.32
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    0.00  400.81  400.81  400.81     0.0 %          1                     1               timeout =     1
                                                                                                   
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    0.00   46.14   46.14   46.14   100.0 %          1          1                      
                                                                       0.00   46.14   46.14   46.14
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 29 21:33:49.469 2009  to  Sun Mar 29 21:40:30.283 2009   (400.81) secs
                     IIF Preset command wait for telescope started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3721                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7442                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .       4                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                          
      Nothing to report

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               4006           
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            24
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .       3                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:01.750 2009  to  Sun Mar 29 18:07:01.750 2009   (  0.00) secs
                     EL bad poly no. 283747: BAD Poly: EL = -7.410665e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:04.821 2009  to  Sun Mar 29 18:07:04.821 2009   (  0.00) secs
                     EL bad poly no. 283803: BAD Poly: EL = -7.411334e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:07.821 2009  to  Sun Mar 29 18:07:07.821 2009   (  0.00) secs
                     EL bad poly no. 283858: BAD Poly: EL = -7.411987e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:10.878 2009  to  Sun Mar 29 18:07:10.878 2009   (  0.00) secs
                     EL bad poly no. 283914: BAD Poly: EL = -7.412652e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:13.890 2009  to  Sun Mar 29 18:07:13.890 2009   (  0.00) secs
                     EL bad poly no. 283969: BAD Poly: EL = -7.413306e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:16.912 2009  to  Sun Mar 29 18:07:16.912 2009   (  0.00) secs
                     EL bad poly no. 284024: BAD Poly: EL = -7.413963e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:19.949 2009  to  Sun Mar 29 18:07:19.949 2009   (  0.00) secs
                     EL bad poly no. 284079: BAD Poly: EL = -7.414622e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:22.964 2009  to  Sun Mar 29 18:07:22.964 2009   (  0.00) secs
                     EL bad poly no. 284134: BAD Poly: EL = -7.415275e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:25.973 2009  to  Sun Mar 29 18:07:25.973 2009   (  0.00) secs
                     EL bad poly no. 284188: BAD Poly: EL = -7.415927e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:28.985 2009  to  Sun Mar 29 18:07:28.985 2009   (  0.00) secs
                     EL bad poly no. 284242: BAD Poly: EL = -7.416579e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:32.038 2009  to  Sun Mar 29 18:07:32.038 2009   (  0.00) secs
                     EL bad poly no. 284296: BAD Poly: EL = -7.417240e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:35.048 2009  to  Sun Mar 29 18:07:35.048 2009   (  0.00) secs
                     EL bad poly no. 284349: BAD Poly: EL = -7.417890e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:38.095 2009  to  Sun Mar 29 18:07:38.095 2009   (  0.00) secs
                     EL bad poly no. 284402: BAD Poly: EL = -7.418549e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:41.152 2009  to  Sun Mar 29 18:07:41.152 2009   (  0.00) secs
                     EL bad poly no. 284456: BAD Poly: EL = -7.419209e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:44.205 2009  to  Sun Mar 29 18:07:44.205 2009   (  0.00) secs
                     EL bad poly no. 284511: BAD Poly: EL = -7.419867e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:47.236 2009  to  Sun Mar 29 18:07:47.236 2009   (  0.00) secs
                     EL bad poly no. 284566: BAD Poly: EL = -7.420520e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:50.251 2009  to  Sun Mar 29 18:07:50.251 2009   (  0.00) secs
                     EL bad poly no. 284620: BAD Poly: EL = -7.421170e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:53.275 2009  to  Sun Mar 29 18:07:53.275 2009   (  0.00) secs
                     EL bad poly no. 284674: BAD Poly: EL = -7.421821e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:56.295 2009  to  Sun Mar 29 18:07:56.295 2009   (  0.00) secs
                     EL bad poly no. 284728: BAD Poly: EL = -7.422470e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:59.332 2009  to  Sun Mar 29 18:07:59.332 2009   (  0.00) secs
                     EL bad poly no. 284782: BAD Poly: EL = -7.423122e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:02.367 2009  to  Sun Mar 29 18:08:02.367 2009   (  0.00) secs
                     EL bad poly no. 284837: BAD Poly: EL = -7.423774e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:05.369 2009  to  Sun Mar 29 18:08:05.369 2009   (  0.00) secs
                     EL bad poly no. 284891: BAD Poly: EL = -7.424418e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:08.414 2009  to  Sun Mar 29 18:08:08.414 2009   (  0.00) secs
                     EL bad poly no. 284947: BAD Poly: EL = -7.425071e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:11.423 2009  to  Sun Mar 29 18:08:11.423 2009   (  0.00) secs
                     EL bad poly no. 285002: BAD Poly: EL = -7.425716e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:14.439 2009  to  Sun Mar 29 18:08:14.439 2009   (  0.00) secs
                     EL bad poly no. 285057: BAD Poly: EL = -7.426361e-01 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.01    0.16    0.15    0.16   100.0 %          2          2                      
                                                                       0.01    0.16    0.15    0.16
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.23    0.23    0.06    0.39   100.0 %          2          2                      
                                                                       0.23    0.23    0.06    0.39
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.18    0.44    0.31    0.57   100.0 %          2          2                      
                                                                       0.18    0.44    0.31    0.57

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   38.77   22.41    0.00   67.17    66.7 %          3                     1           
                                                                       0.00   67.17   67.17   67.17

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            77
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       6                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       6                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:34:37.174 2009  to  Sun Mar 29 21:35:18.164 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:35:18.164 2009  to  Sun Mar 29 21:35:18.216 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   3  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:36:15.416 2009  to  Sun Mar 29 21:36:15.416 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   4  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 30 03:40:11.731 2009  to  Mon Mar 30 03:40:11.731 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   5  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 30 03:40:11.785 2009  to  Mon Mar 30 03:40:11.785 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

   6  FAILED    PMC        thermal.badReceive                                            Mon Mar 30 03:40:11.838 2009  to  Mon Mar 30 03:40:11.838 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.02    0.07    0.05    0.08   100.0 %          2          2                      
                                                                       0.02    0.07    0.05    0.08
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   38.85   22.53    0.00   67.39    66.7 %          3                     1           
                                                                       0.00   67.39   67.39   67.39
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.17    0.17    0.17     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    0.00    0.32    0.32    0.32     0.0 %          1                     1           
                                                                                                   

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:34:37.109 2009  to  Sun Mar 29 21:35:18.097 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   2  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sun Mar 29 21:35:18.043 2009  to  Sun Mar 29 21:35:18.364 2009   (  0.32) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:35:18.097 2009  to  Sun Mar 29 21:35:18.304 2009   (  0.21) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:36:15.480 2009  to  Sun Mar 29 21:36:15.480 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   5  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun Mar 29 21:39:25.475 2009  to  Sun Mar 29 21:39:25.646 2009   (  0.17) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:01.750 2009  to  Sun Mar 29 18:07:01.750 2009   (  0.00) secs
                     EL bad poly no. 283747: BAD Poly: EL = -7.410665e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:04.821 2009  to  Sun Mar 29 18:07:04.821 2009   (  0.00) secs
                     EL bad poly no. 283803: BAD Poly: EL = -7.411334e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:07.821 2009  to  Sun Mar 29 18:07:07.821 2009   (  0.00) secs
                     EL bad poly no. 283858: BAD Poly: EL = -7.411987e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:10.878 2009  to  Sun Mar 29 18:07:10.878 2009   (  0.00) secs
                     EL bad poly no. 283914: BAD Poly: EL = -7.412652e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:13.890 2009  to  Sun Mar 29 18:07:13.890 2009   (  0.00) secs
                     EL bad poly no. 283969: BAD Poly: EL = -7.413306e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:16.912 2009  to  Sun Mar 29 18:07:16.912 2009   (  0.00) secs
                     EL bad poly no. 284024: BAD Poly: EL = -7.413963e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:19.949 2009  to  Sun Mar 29 18:07:19.949 2009   (  0.00) secs
                     EL bad poly no. 284079: BAD Poly: EL = -7.414622e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:22.964 2009  to  Sun Mar 29 18:07:22.964 2009   (  0.00) secs
                     EL bad poly no. 284134: BAD Poly: EL = -7.415275e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:25.973 2009  to  Sun Mar 29 18:07:25.973 2009   (  0.00) secs
                     EL bad poly no. 284188: BAD Poly: EL = -7.415927e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:28.985 2009  to  Sun Mar 29 18:07:28.985 2009   (  0.00) secs
                     EL bad poly no. 284242: BAD Poly: EL = -7.416579e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:32.038 2009  to  Sun Mar 29 18:07:32.038 2009   (  0.00) secs
                     EL bad poly no. 284296: BAD Poly: EL = -7.417240e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:35.048 2009  to  Sun Mar 29 18:07:35.048 2009   (  0.00) secs
                     EL bad poly no. 284349: BAD Poly: EL = -7.417890e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:38.095 2009  to  Sun Mar 29 18:07:38.095 2009   (  0.00) secs
                     EL bad poly no. 284402: BAD Poly: EL = -7.418549e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:41.152 2009  to  Sun Mar 29 18:07:41.152 2009   (  0.00) secs
                     EL bad poly no. 284456: BAD Poly: EL = -7.419209e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:44.205 2009  to  Sun Mar 29 18:07:44.205 2009   (  0.00) secs
                     EL bad poly no. 284511: BAD Poly: EL = -7.419867e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:47.236 2009  to  Sun Mar 29 18:07:47.236 2009   (  0.00) secs
                     EL bad poly no. 284566: BAD Poly: EL = -7.420520e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:50.251 2009  to  Sun Mar 29 18:07:50.251 2009   (  0.00) secs
                     EL bad poly no. 284620: BAD Poly: EL = -7.421170e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:53.275 2009  to  Sun Mar 29 18:07:53.275 2009   (  0.00) secs
                     EL bad poly no. 284674: BAD Poly: EL = -7.421821e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:56.295 2009  to  Sun Mar 29 18:07:56.295 2009   (  0.00) secs
                     EL bad poly no. 284728: BAD Poly: EL = -7.422470e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:07:59.332 2009  to  Sun Mar 29 18:07:59.332 2009   (  0.00) secs
                     EL bad poly no. 284782: BAD Poly: EL = -7.423122e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:02.367 2009  to  Sun Mar 29 18:08:02.367 2009   (  0.00) secs
                     EL bad poly no. 284837: BAD Poly: EL = -7.423774e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:05.369 2009  to  Sun Mar 29 18:08:05.369 2009   (  0.00) secs
                     EL bad poly no. 284891: BAD Poly: EL = -7.424418e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:08.414 2009  to  Sun Mar 29 18:08:08.414 2009   (  0.00) secs
                     EL bad poly no. 284947: BAD Poly: EL = -7.425071e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:11.423 2009  to  Sun Mar 29 18:08:11.423 2009   (  0.00) secs
                     EL bad poly no. 285002: BAD Poly: EL = -7.425716e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 29 18:08:14.439 2009  to  Sun Mar 29 18:08:14.439 2009   (  0.00) secs
                     EL bad poly no. 285057: BAD Poly: EL = -7.426361e-01 rad. Too low.

  26  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 29 21:33:49.469 2009  to  Sun Mar 29 21:40:30.283 2009   (400.81) secs
                     IIF Preset command wait for telescope started for both LBC
                     IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command timed out in 300 seconds for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

  27  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:34:37.109 2009  to  Sun Mar 29 21:35:18.097 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  28  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:34:37.174 2009  to  Sun Mar 29 21:35:18.164 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  29  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sun Mar 29 21:35:18.043 2009  to  Sun Mar 29 21:35:18.364 2009   (  0.32) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  30  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:35:18.164 2009  to  Sun Mar 29 21:35:18.216 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  31  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:35:18.097 2009  to  Sun Mar 29 21:35:18.304 2009   (  0.21) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  32  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Mar 29 21:36:15.416 2009  to  Sun Mar 29 21:36:15.416 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 29 21:36:15.480 2009  to  Sun Mar 29 21:36:15.480 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  34  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Sun Mar 29 21:39:25.475 2009  to  Sun Mar 29 21:39:25.646 2009   (  0.17) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  35  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 30 03:40:11.731 2009  to  Mon Mar 30 03:40:11.731 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  36  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 30 03:40:11.785 2009  to  Mon Mar 30 03:40:11.785 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  37  FAILED    PMC        thermal.badReceive                                            Mon Mar 30 03:40:11.838 2009  to  Mon Mar 30 03:40:11.838 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

**********************************************************