You are here: Foswiki>Software Web>TCSSWReportFile_090327 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 27 2009 to Mar 28 2009
 
    Reporting period beginning:   Fri Mar 27 18:06:03.203 2009
    Reporting period ending:      Sat Mar 28 06:42:58.094 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.11   100.0 %        222        222                      
                                                                       0.01    0.05    0.05    0.11
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.11    0.33    0.24    1.06   100.0 %        330        330                      
                                                                       0.11    0.33    0.24    1.06
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.19    0.16    0.53   100.0 %        611        611                      
                                                                       0.03    0.19    0.16    0.53
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.30    6.11    0.64   35.60    97.3 %        367        357         10           
                                                                       5.28    6.19    2.52   35.60
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.39    4.65    2.69    7.25   100.0 %         36         36                      
                                                                       1.39    4.65    2.69    7.25
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.35    3.96    2.06    6.47   100.0 %         36         36                      
                                                                       1.35    3.96    2.06    6.47
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    9.45   13.20    6.62   44.87   100.0 %         26         26                      
                                                                       9.45   13.20    6.62   44.87
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    3.16    1.89    1.05   17.08   100.0 %         26         26                      
                                                                       3.16    1.89    1.05   17.08
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    6.31    4.19    2.06   28.11   100.0 %         26         26                      
                                                                       6.31    4.19    2.06   28.11
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    4.57    5.90    0.64   57.42    99.2 %        915        908          7           
                                                                       4.53    5.87    0.64   57.42
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.83    5.00    2.53    8.58   100.0 %         36         36                      
                                                                       1.83    5.00    2.53    8.58

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            30

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Fri Mar 27 19:43:20.888 2009  to  Fri Mar 27 19:43:21.534 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   2  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 20:22:06.988 2009  to  Fri Mar 27 20:22:23.022 2009   ( 16.03) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   3  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:22:45.270 2009  to  Fri Mar 27 20:22:56.953 2009   ( 11.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491814081018518e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   4  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 20:24:15.332 2009  to  Fri Mar 27 20:24:39.419 2009   ( 24.09) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   5  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:24:48.026 2009  to  Fri Mar 27 20:25:04.760 2009   ( 16.73) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491814223379629e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:27:21.893 2009  to  Fri Mar 27 20:27:22.559 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   7  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 22:21:08.084 2009  to  Fri Mar 27 22:21:12.504 2009   (  4.42) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

   8  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 22:21:14.613 2009  to  Fri Mar 27 22:21:18.963 2009   (  4.35) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

   9  FAILED    IIF        command.moveFocus                                             Fri Mar 27 22:21:25.321 2009  to  Fri Mar 27 22:21:25.962 2009   (  0.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491822320601852e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  10  FAILED    IIF        command.moveFocus                                             Fri Mar 27 22:21:25.343 2009  to  Fri Mar 27 22:21:25.980 2009   (  0.64) secs
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  11  FAILED    IIF        command.moveFocus                                             Sat Mar 28 01:20:46.742 2009  to  Sat Mar 28 01:20:47.504 2009   (  0.76) secs
                     IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

  12  FAILED    IIF        command.moveFocus                                             Sat Mar 28 01:20:46.743 2009  to  Sat Mar 28 01:20:47.503 2009   (  0.76) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

  13  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:28:42.778 2009  to  Sat Mar 28 02:28:52.222 2009   (  9.44) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  14  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:44:51.375 2009  to  Sat Mar 28 02:44:55.776 2009   (  4.40) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

  15  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:44:58.138 2009  to  Sat Mar 28 02:45:02.452 2009   (  4.31) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

  16  FAILED    IIF        command.moveFocus                                             Sat Mar 28 02:45:08.587 2009  to  Sat Mar 28 02:45:09.296 2009   (  0.71) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  17  FAILED    IIF        command.moveFocus                                             Sat Mar 28 02:45:08.587 2009  to  Sat Mar 28 02:45:09.370 2009   (  0.78) secs
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3747                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7494                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     270                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       8                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      22                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      56                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      20                      
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.Stowpins.retractTimeout. . . . . . . . . . . . .                 12           
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      70                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            37
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      22                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            24
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      39                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnTimeOut. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampsOnTimeOut. . . . . . . . . . . . . . . . . .                  5           
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.ELDrive.Stowpins.stowpinMoving . . . . . . . . . . . . .                  2           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      82                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     173                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     558                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     186                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:21:17.948 2009  to  Fri Mar 27 18:21:17.948 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

   2  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:21:21.610 2009  to  Fri Mar 27 18:21:21.610 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:22:57.492 2009  to  Fri Mar 27 18:22:57.492 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:23:03.009 2009  to  Fri Mar 27 18:23:03.009 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 27 18:25:05.990 2009  to  Fri Mar 27 18:25:05.990 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 27 18:25:05.993 2009  to  Fri Mar 27 18:25:05.993 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   7  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Mar 27 18:25:06.098 2009  to  Fri Mar 27 18:25:06.098 2009   (  0.00) secs
                     drive cabinet has turned on.

   8  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:27:22.779 2009  to  Fri Mar 27 18:27:22.779 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

   9  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:27:23.596 2009  to  Fri Mar 27 18:27:23.596 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  10  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Fri Mar 27 18:27:53.310 2009  to  Fri Mar 27 18:27:53.310 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  11  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:27:55.039 2009  to  Fri Mar 27 18:27:55.039 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  12  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Fri Mar 27 18:28:12.704 2009  to  Fri Mar 27 18:28:12.704 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  13  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:28:13.624 2009  to  Fri Mar 27 18:28:13.624 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  14  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 27 18:28:25.348 2009  to  Fri Mar 27 18:28:25.348 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  15  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:31:30.636 2009  to  Fri Mar 27 18:31:30.636 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  16  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:31:31.247 2009  to  Fri Mar 27 18:31:31.247 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  17  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:34:03.871 2009  to  Fri Mar 27 18:34:03.871 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  18  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 27 18:34:18.400 2009  to  Fri Mar 27 18:34:18.400 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  19  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:37:06.487 2009  to  Fri Mar 27 18:37:06.487 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  20  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:37:30.471 2009  to  Fri Mar 27 18:37:30.471 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  21  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:43:42.373 2009  to  Fri Mar 27 18:43:42.373 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  22  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:43:42.986 2009  to  Fri Mar 27 18:43:42.986 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  23  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.827 2009  to  Fri Mar 27 18:48:33.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  24  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.827 2009  to  Fri Mar 27 18:48:33.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  25  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.828 2009  to  Fri Mar 27 18:48:33.828 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.828 2009  to  Fri Mar 27 18:48:33.828 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.855 2009  to  Fri Mar 27 18:48:33.855 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.855 2009  to  Fri Mar 27 18:48:33.855 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.856 2009  to  Fri Mar 27 18:48:33.856 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.856 2009  to  Fri Mar 27 18:48:33.856 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Mar 27 18:48:34.710 2009  to  Fri Mar 27 18:48:34.710 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Mar 27 18:49:06.125 2009  to  Fri Mar 27 18:49:06.125 2009   (  0.00) secs
                     StowIdleIn: LFT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:53:36.632 2009  to  Fri Mar 27 18:53:36.632 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:56:27.580 2009  to  Fri Mar 27 18:56:27.580 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Mar 28 06:05:52.252 2009  to  Sat Mar 28 06:05:52.252 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Mar 28 06:05:52.267 2009  to  Sat Mar 28 06:05:52.267 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.20   100.0 %        611        611                      
                                                                       0.01    0.06    0.04    0.20
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.14    0.11    0.23   100.0 %        330        330                      
                                                                       0.03    0.14    0.11    0.23
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.06    0.07    0.05    0.22   100.0 %          9          9                      
                                                                       0.06    0.07    0.05    0.22
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.12    0.33    0.06    0.87   100.0 %         36         36                      
                                                                       0.12    0.33    0.06    0.87
     telescope.command.reloadAuthorizedPM . . . . . . . . . . . . .    0.06    0.09    0.05    0.14   100.0 %          2          2                      
                                                                       0.06    0.09    0.05    0.14
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          7          7                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.13    0.12    0.06    0.74   100.0 %         41         41                      
                                                                       0.13    0.12    0.06    0.74
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.21    0.58    0.31    0.84   100.0 %         41         41                      
                                                                       0.21    0.58    0.31    0.84

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  SHUTDOWN  PCS        shutdown                                                      Sat Mar 28 06:05:51.372 2009  to  Sat Mar 28 06:05:51.372 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

   2  STARTUP   PCS        startup                                                       Sat Mar 28 06:08:30.578 2009  to  Sat Mar 28 06:08:30.578 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.71    0.55    0.05    1.06    50.0 %          2          1          1           
                                                                       0.00    1.06    1.06    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.19    2.78    2.05    7.07   100.0 %        214        214                      
                                                                       1.19    2.78    2.05    7.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.98    2.63    2.06    4.06   100.0 %          7          7                      
                                                                       0.98    2.63    2.06    4.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    3.54    2.56    0.05    5.06    50.0 %          2          1          1           
                                                                       0.00    5.06    5.06    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .   46.76   33.11    0.05   66.18    50.0 %          2          1          1           
                                                                       0.00   66.18   66.18   66.18
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.05    2.06   100.0 %          6          6                      
                                                                       0.00    2.06    2.05    2.06
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .    5.78    5.31    0.00   69.19    98.2 %       1358       1335         24           
                                                                       5.73    5.34    1.67   69.19
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    0.00   11.07   11.07   11.07   100.0 %          1          1                      
                                                                       0.00   11.07   11.07   11.07
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .   98.70   49.53    0.00  197.58     0.0 %          3          1          3           
                                                                       0.00  197.58  197.58  197.58
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.04    0.14    0.09    0.18   100.0 %          3          3                      
                                                                       0.04    0.14    0.09    0.18
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.07   100.0 %          5          5                      
                                                                       0.01    0.06    0.05    0.07

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       7                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            58
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     214                      
     mirror.autoRaiseRaiseTimeOut . . . . . . . . . . . . . . . . .                  1           
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             4
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             9
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           372
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor2.panic . . . . . . . . . . . . . . . . .                  1           
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 51           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 51           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      51                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           324
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           306
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  9           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  3           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:06:39.434 2009  to  Fri Mar 27 18:06:39.434 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   2  FAILED    PMC        mirror.command.raise.auto                                     Fri Mar 27 18:09:27.676 2009  to  Fri Mar 27 18:09:27.920 2009   (  0.24) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 8.5833611e+01
                     right PMC Mirror AutoRaise Command Failed because Wrong mirror state

   3  FAILED    PMC        mirror.command.raise.auto                                     Fri Mar 27 18:10:50.994 2009  to  Fri Mar 27 18:10:51.279 2009   (  0.28) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 9.0000008e+01
                     right PMC Mirror AutoRaise Command Failed because Wrong mirror state

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:10:59.894 2009  to  Fri Mar 27 18:10:59.946 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   5  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Fri Mar 27 18:11:09.480 2009  to  Fri Mar 27 18:11:09.480 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

   6  FAILED    PMC        mirror.panic                                                  Fri Mar 27 18:11:09.533 2009  to  Fri Mar 27 18:11:09.533 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

   7  SEQERROR  PMC        mirror.command.raise.auto                                     Fri Mar 27 18:11:10.123 2009  to  Fri Mar 27 18:11:10.123 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

   8  FAILED    PMC        command.recoverPanic                                          Fri Mar 27 18:11:13.251 2009  to  Fri Mar 27 18:11:13.304 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

   9  FAILED    PMC        command.turnAllAirLoops                                       Fri Mar 27 18:11:15.219 2009  to  Fri Mar 27 18:11:15.272 2009   (  0.05) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because Wrong mirror state

  10  FAILED    PMC        actuator.command.activate.all                                 Fri Mar 27 18:12:42.385 2009  to  Fri Mar 27 18:12:42.435 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:16:36.164 2009  to  Fri Mar 27 18:16:56.254 2009   ( 20.09) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Mar 27 19:00:28.365 2009  to  Fri Mar 27 19:00:28.365 2009   (  0.00) secs
                     right PMC Actuator 212 force monitor 2 PANIC! -186.9 lbs, limit is -62.8

  13  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:21:30.044 2009  to  Fri Mar 27 19:21:37.112 2009   (  7.07) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:26:17.916 2009  to  Fri Mar 27 19:26:17.916 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:26:17.969 2009  to  Fri Mar 27 19:26:17.969 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:26:21.816 2009  to  Fri Mar 27 19:26:21.816 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:26:21.867 2009  to  Fri Mar 27 19:26:21.867 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:31:44.519 2009  to  Fri Mar 27 19:31:44.519 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:31:44.467 2009  to  Fri Mar 27 19:31:44.467 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  20  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:33:51.607 2009  to  Fri Mar 27 19:34:09.693 2009   ( 18.09) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:34:33.246 2009  to  Fri Mar 27 19:34:49.328 2009   ( 16.08) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:35:54.634 2009  to  Fri Mar 27 19:35:54.634 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:35:54.686 2009  to  Fri Mar 27 19:35:54.686 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  24  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:05.691 2009  to  Fri Mar 27 19:43:21.118 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:21.118 2009  to  Fri Mar 27 19:43:21.170 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:21.774 2009  to  Fri Mar 27 19:43:21.774 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  27  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:46:11.887 2009  to  Fri Mar 27 19:46:11.887 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:46:11.835 2009  to  Fri Mar 27 19:46:11.835 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  29  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:22:10.601 2009  to  Fri Mar 27 20:22:22.677 2009   ( 12.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  30  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:22:45.508 2009  to  Fri Mar 27 20:22:56.582 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:24:18.914 2009  to  Fri Mar 27 20:24:39.003 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  32  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:24:48.266 2009  to  Fri Mar 27 20:25:04.354 2009   ( 16.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:25:07.542 2009  to  Fri Mar 27 20:25:29.638 2009   ( 22.10) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:17.737 2009  to  Fri Mar 27 20:27:22.136 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  35  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:20.430 2009  to  Fri Mar 27 20:27:22.127 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  36  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:22.127 2009  to  Fri Mar 27 20:27:22.180 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:23.487 2009  to  Fri Mar 27 20:27:23.487 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  38  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:24.195 2009  to  Fri Mar 27 20:27:24.195 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  39  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 27 20:33:51.102 2009  to  Fri Mar 27 20:33:51.102 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

  40  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.050 2009  to  Fri Mar 27 20:33:51.050 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  41  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.456 2009  to  Fri Mar 27 20:33:51.456 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  42  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.810 2009  to  Fri Mar 27 20:33:51.810 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  43  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:52.164 2009  to  Fri Mar 27 20:33:52.164 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  44  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:35:17.504 2009  to  Fri Mar 27 20:35:17.504 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:35:17.555 2009  to  Fri Mar 27 20:35:17.555 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:40:33.409 2009  to  Fri Mar 27 20:40:33.409 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:40:33.357 2009  to  Fri Mar 27 20:40:33.357 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:44:44.572 2009  to  Fri Mar 27 20:44:44.572 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:44:44.519 2009  to  Fri Mar 27 20:44:44.519 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  50  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:47:37.546 2009  to  Fri Mar 27 20:47:37.546 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:47:37.494 2009  to  Fri Mar 27 20:47:37.494 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:13:43.159 2009  to  Fri Mar 27 21:13:43.159 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:13:43.211 2009  to  Fri Mar 27 21:13:43.211 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:22:22.710 2009  to  Fri Mar 27 21:22:22.710 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:22:22.658 2009  to  Fri Mar 27 21:22:22.658 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  56  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:33:24.534 2009  to  Fri Mar 27 21:33:24.534 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:33:24.482 2009  to  Fri Mar 27 21:33:24.482 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:43:27.066 2009  to  Fri Mar 27 21:43:27.066 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  59  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:43:27.117 2009  to  Fri Mar 27 21:43:27.117 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:51:39.792 2009  to  Fri Mar 27 21:51:39.792 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:51:39.844 2009  to  Fri Mar 27 21:51:39.844 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:55:12.086 2009  to  Fri Mar 27 21:55:12.086 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:55:12.138 2009  to  Fri Mar 27 21:55:12.138 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:13:38.120 2009  to  Fri Mar 27 22:13:38.120 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:13:38.173 2009  to  Fri Mar 27 22:13:38.173 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:20:57.479 2009  to  Fri Mar 27 22:21:12.103 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:20:59.990 2009  to  Fri Mar 27 22:21:18.520 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:12.103 2009  to  Fri Mar 27 22:21:12.158 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:18.520 2009  to  Fri Mar 27 22:21:18.572 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:25.557 2009  to  Fri Mar 27 22:21:25.610 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  71  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:25.575 2009  to  Fri Mar 27 22:21:25.629 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  72  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:23:14.055 2009  to  Fri Mar 27 22:23:14.055 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  73  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:23:14.002 2009  to  Fri Mar 27 22:23:14.002 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  74  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:26:01.509 2009  to  Fri Mar 27 22:26:01.509 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  75  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:26:01.561 2009  to  Fri Mar 27 22:26:01.561 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:29:53.374 2009  to  Fri Mar 27 22:29:53.374 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:29:53.427 2009  to  Fri Mar 27 22:29:53.427 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:29:53.842 2009  to  Fri Mar 27 22:29:53.842 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  79  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:29:53.894 2009  to  Fri Mar 27 22:29:53.894 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  80  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:34:19.253 2009  to  Fri Mar 27 22:34:19.253 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  81  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:34:19.201 2009  to  Fri Mar 27 22:34:19.201 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  82  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:41:52.067 2009  to  Fri Mar 27 22:41:52.067 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  83  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:41:52.120 2009  to  Fri Mar 27 22:41:52.120 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  84  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 27 22:51:04.941 2009  to  Fri Mar 27 22:51:04.941 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  85  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 22:51:04.886 2009  to  Fri Mar 27 22:51:04.886 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  86  FAILED    PMC        thermal.badReceive                                            Fri Mar 27 22:51:04.994 2009  to  Fri Mar 27 22:51:04.994 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  87  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 23:17:34.006 2009  to  Fri Mar 27 23:17:34.006 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  88  FAILED    PMC        VxInterface.close                                             Fri Mar 27 23:17:34.060 2009  to  Fri Mar 27 23:17:34.060 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  89  FAILED    PMC        VxInterface.close                                             Sat Mar 28 00:06:53.907 2009  to  Sat Mar 28 00:06:53.907 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 28 00:06:53.855 2009  to  Sat Mar 28 00:06:53.855 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  91  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 28 00:15:21.129 2009  to  Sat Mar 28 00:15:21.129 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  92  FAILED    PMC        VxInterface.close                                             Sat Mar 28 00:15:21.182 2009  to  Sat Mar 28 00:15:21.182 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  93  FAILED    PMC        VxInterface.packetReadError                                   Sat Mar 28 01:30:06.266 2009  to  Sat Mar 28 01:30:06.266 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

  94  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.214 2009  to  Sat Mar 28 01:30:06.214 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  95  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.620 2009  to  Sat Mar 28 01:30:06.620 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  96  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.976 2009  to  Sat Mar 28 01:30:06.976 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  97  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:07.330 2009  to  Sat Mar 28 01:30:07.330 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.57    5.64    0.41   57.18    99.2 %        915        908          7           
                                                                       4.53    5.62    0.41   57.18
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.12   100.0 %         52         52                      
                                                                       0.01    0.05    0.05    0.12
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.10    5.87    0.40   35.47    97.5 %        403        393         10           
                                                                       5.07    5.94    2.40   35.47
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.57    5.75    0.52   57.29    99.2 %        915        908          7           
                                                                       4.53    5.73    0.52   57.29
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.77    5.52    0.00   56.96    98.9 %        928        918         10           
                                                                       4.71    5.48    0.19   56.96
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    5.78    5.45    0.00   69.32    98.2 %       1358       1335         24           
                                                                       5.73    5.47    1.80   69.32
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.04    2.20    2.18    2.29   100.0 %          6          6                      
                                                                       0.04    2.20    2.18    2.29
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.97    2.77    2.18    4.19   100.0 %          7          7                      
                                                                       0.97    2.77    2.18    4.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.06    0.10    0.07    0.80   100.0 %        372        372                      
                                                                       0.06    0.10    0.07    0.80
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.19    0.25    0.06    0.43    33.3 %          3          1          2           
                                                                       0.00    0.43    0.43    0.43
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   22.13   14.69    0.00   47.63    75.0 %          3          4                      
                                                                      24.31   19.59    4.53   47.63
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   20.53   33.70   11.32   59.40    83.3 %          6          5          1           
                                                                      22.10   35.96   11.32   59.40
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.10    5.76    0.29   35.36    97.5 %        403        393         10           
                                                                       5.07    5.83    2.29   35.36
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %         13         13                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.05    0.05    0.13   100.0 %        928        928                      
                                                                       0.01    0.05    0.05    0.13

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                642           

PSF Events of Interest

   1  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:06:39.501 2009  to  Fri Mar 27 18:06:39.501 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   2  SEQERROR  PSF        primaryMirror.command.revert                                  Fri Mar 27 18:06:39.556 2009  to  Fri Mar 27 18:06:39.556 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror revert to just collimation table complete

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:10:59.831 2009  to  Fri Mar 27 18:11:00.017 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:16:36.105 2009  to  Fri Mar 27 18:16:56.325 2009   ( 20.22) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:21:29.899 2009  to  Fri Mar 27 19:21:37.178 2009   (  7.28) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   6  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Mar 27 19:21:38.574 2009  to  Fri Mar 27 19:21:38.830 2009   (  0.26) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   7  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Mar 27 19:21:41.173 2009  to  Fri Mar 27 19:21:41.228 2009   (  0.06) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   8  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 19:33:51.289 2009  to  Fri Mar 27 19:34:09.816 2009   ( 18.53) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:33:51.534 2009  to  Fri Mar 27 19:34:09.758 2009   ( 18.22) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 19:34:32.988 2009  to  Fri Mar 27 19:34:49.450 2009   ( 16.46) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:34:33.184 2009  to  Fri Mar 27 19:34:49.394 2009   ( 16.21) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:05.626 2009  to  Fri Mar 27 19:43:21.054 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  13  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 19:43:20.949 2009  to  Fri Mar 27 19:43:21.364 2009   (  0.41) secs
                     left PSF SetInstrumentOffsets failed

  14  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:21.054 2009  to  Fri Mar 27 19:43:21.234 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  15  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 19:43:21.002 2009  to  Fri Mar 27 19:43:21.308 2009   (  0.31) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  16  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:21.836 2009  to  Fri Mar 27 19:43:21.836 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  17  FAILED    PSF        command.setZernikes                                           Fri Mar 27 20:22:07.057 2009  to  Fri Mar 27 20:22:22.905 2009   ( 15.85) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  18  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 20:22:07.110 2009  to  Fri Mar 27 20:22:22.850 2009   ( 15.74) secs
                     right PSF ApplyZernikes failed

  19  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 20:22:07.271 2009  to  Fri Mar 27 20:22:22.795 2009   ( 15.52) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:22:10.538 2009  to  Fri Mar 27 20:22:22.741 2009   ( 12.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:22:45.333 2009  to  Fri Mar 27 20:22:56.786 2009   ( 11.45) secs
                     right PSF SetInstrumentOffsets failed

  22  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:22:45.386 2009  to  Fri Mar 27 20:22:56.731 2009   ( 11.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  23  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:22:45.438 2009  to  Fri Mar 27 20:22:56.646 2009   ( 11.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PSF        command.setZernikes                                           Fri Mar 27 20:24:15.402 2009  to  Fri Mar 27 20:24:39.238 2009   ( 23.84) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  25  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 20:24:15.455 2009  to  Fri Mar 27 20:24:39.182 2009   ( 23.73) secs
                     right PSF ApplyZernikes failed

  26  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 20:24:15.616 2009  to  Fri Mar 27 20:24:39.127 2009   ( 23.51) secs
                     right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  27  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:24:18.847 2009  to  Fri Mar 27 20:24:39.070 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  28  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:24:48.091 2009  to  Fri Mar 27 20:25:04.538 2009   ( 16.45) secs
                     right PSF SetInstrumentOffsets failed

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:24:48.196 2009  to  Fri Mar 27 20:25:04.423 2009   ( 16.23) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  30  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:24:48.143 2009  to  Fri Mar 27 20:25:04.479 2009   ( 16.34) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  31  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Fri Mar 27 20:25:07.401 2009  to  Fri Mar 27 20:25:29.758 2009   ( 22.36) secs
                     right PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  32  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:25:07.475 2009  to  Fri Mar 27 20:25:29.702 2009   ( 22.23) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:17.593 2009  to  Fri Mar 27 20:27:22.068 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  34  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:20.364 2009  to  Fri Mar 27 20:27:22.061 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  35  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:27:21.955 2009  to  Fri Mar 27 20:27:22.392 2009   (  0.44) secs
                     left PSF SetInstrumentOffsets failed

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:22.061 2009  to  Fri Mar 27 20:27:22.279 2009   (  0.22) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:27:22.008 2009  to  Fri Mar 27 20:27:22.335 2009   (  0.33) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  38  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:23.551 2009  to  Fri Mar 27 20:27:23.551 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  39  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:24.260 2009  to  Fri Mar 27 20:27:24.260 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  40  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:03.370 2009  to  Fri Mar 27 20:47:03.370 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:03.625 2009  to  Fri Mar 27 20:47:03.625 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:05.708 2009  to  Fri Mar 27 20:47:05.708 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:05.965 2009  to  Fri Mar 27 20:47:05.965 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:08.656 2009  to  Fri Mar 27 20:47:08.656 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.1464310e-04 -1.3368130e-03 3.1356812e-03 1.0906219e-01 7.6103210e-02 6.9839478e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:08.911 2009  to  Fri Mar 27 20:47:08.911 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.1464310e-04 -1.3368130e-03 3.1356812e-03 1.0906219e-01 7.6103210e-02 6.9839478e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:14.617 2009  to  Fri Mar 27 20:47:14.617 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.276 2009  to  Fri Mar 27 20:47:15.276 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.531 2009  to  Fri Mar 27 20:47:15.531 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.786 2009  to  Fri Mar 27 20:47:15.786 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

  50  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.243 2009  to  Fri Mar 27 20:47:16.243 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

  51  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.498 2009  to  Fri Mar 27 20:47:16.498 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

  52  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.753 2009  to  Fri Mar 27 20:47:16.753 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

  53  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:19.843 2009  to  Fri Mar 27 20:47:19.843 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1198521e-03 -1.0499954e-03 3.1311512e-03 9.3006134e-02 4.9118042e-02 9.0631485e-02

  54  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.098 2009  to  Fri Mar 27 20:47:20.098 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1198521e-03 -1.0499954e-03 3.1311512e-03 9.3006134e-02 4.9118042e-02 9.0631485e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.353 2009  to  Fri Mar 27 20:47:20.353 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.608 2009  to  Fri Mar 27 20:47:20.608 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

  57  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.866 2009  to  Fri Mar 27 20:47:20.866 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  58  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:21.121 2009  to  Fri Mar 27 20:47:21.121 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

  59  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:22.594 2009  to  Fri Mar 27 20:47:22.594 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

  60  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:22.851 2009  to  Fri Mar 27 20:47:22.851 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

  61  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:23.106 2009  to  Fri Mar 27 20:47:23.106 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

  62  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:24.783 2009  to  Fri Mar 27 20:47:24.783 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

  63  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:25.038 2009  to  Fri Mar 27 20:47:25.038 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1374950e-03 -1.0560751e-03 3.1458139e-03 2.4360657e-02 8.8432312e-02 9.0721130e-02

  64  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:25.294 2009  to  Fri Mar 27 20:47:25.294 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1374950e-03 -1.0560751e-03 3.1458139e-03 2.4360657e-02 8.8432312e-02 9.0721130e-02

  65  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:20:57.410 2009  to  Fri Mar 27 22:21:12.033 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:20:59.927 2009  to  Fri Mar 27 22:21:18.458 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  FAILED    PSF        command.setZernikes                                           Fri Mar 27 22:21:08.150 2009  to  Fri Mar 27 22:21:12.388 2009   (  4.24) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  68  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 22:21:08.203 2009  to  Fri Mar 27 22:21:12.333 2009   (  4.13) secs
                     right PSF ApplyZernikes failed

  69  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 22:21:08.364 2009  to  Fri Mar 27 22:21:12.278 2009   (  3.91) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:12.033 2009  to  Fri Mar 27 22:21:12.223 2009   (  0.19) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  71  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 22:21:14.734 2009  to  Fri Mar 27 22:21:18.793 2009   (  4.06) secs
                     left PSF ApplyZernikes failed

  72  FAILED    PSF        command.setZernikes                                           Fri Mar 27 22:21:14.681 2009  to  Fri Mar 27 22:21:18.849 2009   (  4.17) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  73  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 22:21:14.896 2009  to  Fri Mar 27 22:21:18.700 2009   (  3.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  74  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:18.458 2009  to  Fri Mar 27 22:21:18.643 2009   (  0.19) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  75  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 22:21:25.390 2009  to  Fri Mar 27 22:21:25.793 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

  76  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 22:21:25.408 2009  to  Fri Mar 27 22:21:25.810 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  77  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 22:21:25.443 2009  to  Fri Mar 27 22:21:25.736 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  78  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 22:21:25.460 2009  to  Fri Mar 27 22:21:25.755 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  79  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:25.496 2009  to  Fri Mar 27 22:21:25.678 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  80  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:25.512 2009  to  Fri Mar 27 22:21:25.700 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  81  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 23:55:55.950 2009  to  Fri Mar 27 23:56:01.393 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  82  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 23:56:14.560 2009  to  Fri Mar 27 23:56:14.560 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  83  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:08.627 2009  to  Sat Mar 28 00:03:11.550 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  84  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:11.550 2009  to  Sat Mar 28 00:03:16.590 2009   (  5.04) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  85  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:17.430 2009  to  Sat Mar 28 00:03:17.430 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  86  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 01:20:46.803 2009  to  Sat Mar 28 01:20:47.261 2009   (  0.46) secs
                     left PSF SetInstrumentOffsets failed

  87  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 01:20:46.804 2009  to  Sat Mar 28 01:20:47.258 2009   (  0.45) secs
                     right PSF SetInstrumentOffsets failed

  88  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 01:20:46.856 2009  to  Sat Mar 28 01:20:47.205 2009   (  0.35) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  89  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 01:20:46.857 2009  to  Sat Mar 28 01:20:47.203 2009   (  0.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  90  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:28:42.846 2009  to  Sat Mar 28 02:28:52.104 2009   (  9.26) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  91  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:28:42.898 2009  to  Sat Mar 28 02:28:52.047 2009   (  9.15) secs
                     right PSF ApplyZernikes failed

  92  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:28:43.059 2009  to  Sat Mar 28 02:28:51.991 2009   (  8.93) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  93  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:44:51.440 2009  to  Sat Mar 28 02:44:55.661 2009   (  4.22) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  94  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:44:51.492 2009  to  Sat Mar 28 02:44:55.606 2009   (  4.11) secs
                     right PSF ApplyZernikes failed

  95  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:44:51.653 2009  to  Sat Mar 28 02:44:55.551 2009   (  3.90) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  96  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:44:58.203 2009  to  Sat Mar 28 02:45:02.336 2009   (  4.13) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  97  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:44:58.256 2009  to  Sat Mar 28 02:45:02.279 2009   (  4.02) secs
                     left PSF ApplyZernikes failed

  98  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:44:58.419 2009  to  Sat Mar 28 02:45:02.221 2009   (  3.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  99  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 02:45:08.649 2009  to  Sat Mar 28 02:45:09.050 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

 100  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 02:45:08.649 2009  to  Sat Mar 28 02:45:09.202 2009   (  0.55) secs
                     right PSF SetInstrumentOffsets failed

 101  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 02:45:08.702 2009  to  Sat Mar 28 02:45:08.994 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 102  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 02:45:08.702 2009  to  Sat Mar 28 02:45:09.146 2009   (  0.44) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:06:39.434 2009  to  Fri Mar 27 18:06:39.434 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   2  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:06:39.501 2009  to  Fri Mar 27 18:06:39.501 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   3  SEQERROR  PSF        primaryMirror.command.revert                                  Fri Mar 27 18:06:39.556 2009  to  Fri Mar 27 18:06:39.556 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror revert to just collimation table complete

   4  FAILED    PMC        mirror.command.raise.auto                                     Fri Mar 27 18:09:27.676 2009  to  Fri Mar 27 18:09:27.920 2009   (  0.24) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 8.5833611e+01
                     right PMC Mirror AutoRaise Command Failed because Wrong mirror state

   5  FAILED    PMC        mirror.command.raise.auto                                     Fri Mar 27 18:10:50.994 2009  to  Fri Mar 27 18:10:51.279 2009   (  0.28) secs
                     right PMC Mirror Command Set Elevation Angle Started for elevation 9.0000008e+01
                     right PMC Mirror AutoRaise Command Failed because Wrong mirror state

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:10:59.894 2009  to  Fri Mar 27 18:10:59.946 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:10:59.831 2009  to  Fri Mar 27 18:11:00.017 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   8  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Fri Mar 27 18:11:09.480 2009  to  Fri Mar 27 18:11:09.480 2009   (  0.00) secs
                     right PMC Auto-raise time-out: raise failed to finish in alloted time

   9  FAILED    PMC        mirror.panic                                                  Fri Mar 27 18:11:09.533 2009  to  Fri Mar 27 18:11:09.533 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  10  SEQERROR  PMC        mirror.command.raise.auto                                     Fri Mar 27 18:11:10.123 2009  to  Fri Mar 27 18:11:10.123 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  11  FAILED    PMC        command.recoverPanic                                          Fri Mar 27 18:11:13.251 2009  to  Fri Mar 27 18:11:13.304 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

  12  FAILED    PMC        command.turnAllAirLoops                                       Fri Mar 27 18:11:15.219 2009  to  Fri Mar 27 18:11:15.272 2009   (  0.05) secs
                     right PMC TurnAllAirLoops Command Started for ONOFF Flag: 0
                     right PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because Wrong mirror state

  13  FAILED    PMC        actuator.command.activate.all                                 Fri Mar 27 18:12:42.385 2009  to  Fri Mar 27 18:12:42.435 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 18:16:36.164 2009  to  Fri Mar 27 18:16:56.254 2009   ( 20.09) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 18:16:36.105 2009  to  Fri Mar 27 18:16:56.325 2009   ( 20.22) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:21:17.948 2009  to  Fri Mar 27 18:21:17.948 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  17  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:21:21.610 2009  to  Fri Mar 27 18:21:21.610 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  18  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:22:57.492 2009  to  Fri Mar 27 18:22:57.492 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  19  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:23:03.009 2009  to  Fri Mar 27 18:23:03.009 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 27 18:25:05.990 2009  to  Fri Mar 27 18:25:05.990 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 27 18:25:05.993 2009  to  Fri Mar 27 18:25:05.993 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  22  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Mar 27 18:25:06.098 2009  to  Fri Mar 27 18:25:06.098 2009   (  0.00) secs
                     drive cabinet has turned on.

  23  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:27:22.779 2009  to  Fri Mar 27 18:27:22.779 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  24  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:27:23.596 2009  to  Fri Mar 27 18:27:23.596 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  25  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Fri Mar 27 18:27:53.310 2009  to  Fri Mar 27 18:27:53.310 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  26  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:27:55.039 2009  to  Fri Mar 27 18:27:55.039 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  27  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnTimeOut                                   Fri Mar 27 18:28:12.704 2009  to  Fri Mar 27 18:28:12.704 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  28  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:28:13.624 2009  to  Fri Mar 27 18:28:13.624 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  29  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 27 18:28:25.348 2009  to  Fri Mar 27 18:28:25.348 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  30  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:31:30.636 2009  to  Fri Mar 27 18:31:30.636 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:31:31.247 2009  to  Fri Mar 27 18:31:31.247 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:34:03.871 2009  to  Fri Mar 27 18:34:03.871 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 27 18:34:18.400 2009  to  Fri Mar 27 18:34:18.400 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:37:06.487 2009  to  Fri Mar 27 18:37:06.487 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  35  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Fri Mar 27 18:37:30.471 2009  to  Fri Mar 27 18:37:30.471 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  36  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:43:42.373 2009  to  Fri Mar 27 18:43:42.373 2009   (  0.00) secs
                     StowRetracting: RT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  37  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:43:42.986 2009  to  Fri Mar 27 18:43:42.986 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.827 2009  to  Fri Mar 27 18:48:33.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.827 2009  to  Fri Mar 27 18:48:33.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.828 2009  to  Fri Mar 27 18:48:33.828 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.828 2009  to  Fri Mar 27 18:48:33.828 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  42  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.855 2009  to  Fri Mar 27 18:48:33.855 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.855 2009  to  Fri Mar 27 18:48:33.855 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.856 2009  to  Fri Mar 27 18:48:33.856 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 27 18:48:33.856 2009  to  Fri Mar 27 18:48:33.856 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Mar 27 18:48:34.710 2009  to  Fri Mar 27 18:48:34.710 2009   (  0.00) secs
                     StowIdleIn: RT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  47  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Mar 27 18:49:06.125 2009  to  Fri Mar 27 18:49:06.125 2009   (  0.00) secs
                     StowIdleIn: LFT StowIdleIn: stowpin is moving but hasn''t been commanded to move.

  48  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:53:36.632 2009  to  Fri Mar 27 18:53:36.632 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  49  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.retractTimeout                         Fri Mar 27 18:56:27.580 2009  to  Fri Mar 27 18:56:27.580 2009   (  0.00) secs
                     StowRetracting: LFT StowRetracting: stowpin retract process has timed out. It ran more than 90000 seconds without completing.

  50  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Mar 27 19:00:28.365 2009  to  Fri Mar 27 19:00:28.365 2009   (  0.00) secs
                     right PMC Actuator 212 force monitor 2 PANIC! -186.9 lbs, limit is -62.8

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:21:29.899 2009  to  Fri Mar 27 19:21:37.178 2009   (  7.28) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  52  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:21:30.044 2009  to  Fri Mar 27 19:21:37.112 2009   (  7.07) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Mar 27 19:21:38.574 2009  to  Fri Mar 27 19:21:38.830 2009   (  0.26) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  54  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Fri Mar 27 19:21:41.173 2009  to  Fri Mar 27 19:21:41.228 2009   (  0.06) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  55  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:26:17.916 2009  to  Fri Mar 27 19:26:17.916 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:26:17.969 2009  to  Fri Mar 27 19:26:17.969 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:26:21.816 2009  to  Fri Mar 27 19:26:21.816 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:26:21.867 2009  to  Fri Mar 27 19:26:21.867 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:31:44.519 2009  to  Fri Mar 27 19:31:44.519 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:31:44.467 2009  to  Fri Mar 27 19:31:44.467 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  61  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 19:33:51.289 2009  to  Fri Mar 27 19:34:09.816 2009   ( 18.53) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:33:51.534 2009  to  Fri Mar 27 19:34:09.758 2009   ( 18.22) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:33:51.607 2009  to  Fri Mar 27 19:34:09.693 2009   ( 18.09) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 19:34:32.988 2009  to  Fri Mar 27 19:34:49.450 2009   ( 16.46) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:34:33.246 2009  to  Fri Mar 27 19:34:49.328 2009   ( 16.08) secs
                     right PMC Mirror ChaseStop Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:34:33.184 2009  to  Fri Mar 27 19:34:49.394 2009   ( 16.21) secs
                     right PSF primary mirror chaseStop started
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:35:54.634 2009  to  Fri Mar 27 19:35:54.634 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  68  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:35:54.686 2009  to  Fri Mar 27 19:35:54.686 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  69  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:05.691 2009  to  Fri Mar 27 19:43:21.118 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  70  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:05.626 2009  to  Fri Mar 27 19:43:21.054 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  71  FAILED    IIF        command.moveFocus                                             Fri Mar 27 19:43:20.888 2009  to  Fri Mar 27 19:43:21.534 2009   (  0.65) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  72  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 19:43:20.949 2009  to  Fri Mar 27 19:43:21.364 2009   (  0.41) secs
                     left PSF SetInstrumentOffsets failed

  73  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:21.054 2009  to  Fri Mar 27 19:43:21.234 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  74  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 19:43:21.002 2009  to  Fri Mar 27 19:43:21.308 2009   (  0.31) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  75  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:21.118 2009  to  Fri Mar 27 19:43:21.170 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  76  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 19:43:21.774 2009  to  Fri Mar 27 19:43:21.774 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  77  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 19:43:21.836 2009  to  Fri Mar 27 19:43:21.836 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  78  FAILED    PMC        VxInterface.close                                             Fri Mar 27 19:46:11.887 2009  to  Fri Mar 27 19:46:11.887 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  79  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 19:46:11.835 2009  to  Fri Mar 27 19:46:11.835 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  80  FAILED    PSF        command.setZernikes                                           Fri Mar 27 20:22:07.057 2009  to  Fri Mar 27 20:22:22.905 2009   ( 15.85) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  81  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 20:22:06.988 2009  to  Fri Mar 27 20:22:23.022 2009   ( 16.03) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  82  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 20:22:07.110 2009  to  Fri Mar 27 20:22:22.850 2009   ( 15.74) secs
                     right PSF ApplyZernikes failed

  83  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 20:22:07.271 2009  to  Fri Mar 27 20:22:22.795 2009   ( 15.52) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:22:10.601 2009  to  Fri Mar 27 20:22:22.677 2009   ( 12.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:22:10.538 2009  to  Fri Mar 27 20:22:22.741 2009   ( 12.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  86  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:22:45.333 2009  to  Fri Mar 27 20:22:56.786 2009   ( 11.45) secs
                     right PSF SetInstrumentOffsets failed

  87  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:22:45.270 2009  to  Fri Mar 27 20:22:56.953 2009   ( 11.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491814081018518e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  88  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:22:45.386 2009  to  Fri Mar 27 20:22:56.731 2009   ( 11.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  89  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:22:45.508 2009  to  Fri Mar 27 20:22:56.582 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  90  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:22:45.438 2009  to  Fri Mar 27 20:22:56.646 2009   ( 11.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  91  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 20:24:15.332 2009  to  Fri Mar 27 20:24:39.419 2009   ( 24.09) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  92  FAILED    PSF        command.setZernikes                                           Fri Mar 27 20:24:15.402 2009  to  Fri Mar 27 20:24:39.238 2009   ( 23.84) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  93  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 20:24:15.455 2009  to  Fri Mar 27 20:24:39.182 2009   ( 23.73) secs
                     right PSF ApplyZernikes failed

  94  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 20:24:15.616 2009  to  Fri Mar 27 20:24:39.127 2009   ( 23.51) secs
                     right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  95  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:24:18.847 2009  to  Fri Mar 27 20:24:39.070 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  96  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:24:18.914 2009  to  Fri Mar 27 20:24:39.003 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:24:48.091 2009  to  Fri Mar 27 20:25:04.538 2009   ( 16.45) secs
                     right PSF SetInstrumentOffsets failed

  98  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:24:48.026 2009  to  Fri Mar 27 20:25:04.760 2009   ( 16.73) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491814223379629e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  99  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:24:48.196 2009  to  Fri Mar 27 20:25:04.423 2009   ( 16.23) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 100  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:24:48.143 2009  to  Fri Mar 27 20:25:04.479 2009   ( 16.34) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 101  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:24:48.266 2009  to  Fri Mar 27 20:25:04.354 2009   ( 16.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 102  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Fri Mar 27 20:25:07.401 2009  to  Fri Mar 27 20:25:29.758 2009   ( 22.36) secs
                     right PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

 103  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:25:07.542 2009  to  Fri Mar 27 20:25:29.638 2009   ( 22.10) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 104  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:25:07.475 2009  to  Fri Mar 27 20:25:29.702 2009   ( 22.23) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 105  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:17.593 2009  to  Fri Mar 27 20:27:22.068 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 106  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:17.737 2009  to  Fri Mar 27 20:27:22.136 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 107  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:20.430 2009  to  Fri Mar 27 20:27:22.127 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 108  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:20.364 2009  to  Fri Mar 27 20:27:22.061 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 109  FAILED    IIF        command.moveFocus                                             Fri Mar 27 20:27:21.893 2009  to  Fri Mar 27 20:27:22.559 2009   (  0.67) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 110  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 20:27:21.955 2009  to  Fri Mar 27 20:27:22.392 2009   (  0.44) secs
                     left PSF SetInstrumentOffsets failed

 111  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:22.061 2009  to  Fri Mar 27 20:27:22.279 2009   (  0.22) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 112  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 20:27:22.008 2009  to  Fri Mar 27 20:27:22.335 2009   (  0.33) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 113  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:22.127 2009  to  Fri Mar 27 20:27:22.180 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 114  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:23.487 2009  to  Fri Mar 27 20:27:23.487 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

 115  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:23.551 2009  to  Fri Mar 27 20:27:23.551 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 116  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 20:27:24.195 2009  to  Fri Mar 27 20:27:24.195 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

 117  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 20:27:24.260 2009  to  Fri Mar 27 20:27:24.260 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 118  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 27 20:33:51.102 2009  to  Fri Mar 27 20:33:51.102 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

 119  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.050 2009  to  Fri Mar 27 20:33:51.050 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 120  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.456 2009  to  Fri Mar 27 20:33:51.456 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 121  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:51.810 2009  to  Fri Mar 27 20:33:51.810 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 122  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 20:33:52.164 2009  to  Fri Mar 27 20:33:52.164 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 123  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:35:17.504 2009  to  Fri Mar 27 20:35:17.504 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 124  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:35:17.555 2009  to  Fri Mar 27 20:35:17.555 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 125  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:40:33.409 2009  to  Fri Mar 27 20:40:33.409 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 126  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:40:33.357 2009  to  Fri Mar 27 20:40:33.357 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 127  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:44:44.572 2009  to  Fri Mar 27 20:44:44.572 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 128  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:44:44.519 2009  to  Fri Mar 27 20:44:44.519 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 129  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:03.370 2009  to  Fri Mar 27 20:47:03.370 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 130  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:03.625 2009  to  Fri Mar 27 20:47:03.625 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 131  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:05.708 2009  to  Fri Mar 27 20:47:05.708 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 132  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:05.965 2009  to  Fri Mar 27 20:47:05.965 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 133  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:08.656 2009  to  Fri Mar 27 20:47:08.656 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.1464310e-04 -1.3368130e-03 3.1356812e-03 1.0906219e-01 7.6103210e-02 6.9839478e-02

 134  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:08.911 2009  to  Fri Mar 27 20:47:08.911 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -6.1464310e-04 -1.3368130e-03 3.1356812e-03 1.0906219e-01 7.6103210e-02 6.9839478e-02

 135  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:14.617 2009  to  Fri Mar 27 20:47:14.617 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 136  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.276 2009  to  Fri Mar 27 20:47:15.276 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

 137  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.531 2009  to  Fri Mar 27 20:47:15.531 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

 138  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:15.786 2009  to  Fri Mar 27 20:47:15.786 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

 139  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.243 2009  to  Fri Mar 27 20:47:16.243 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

 140  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.498 2009  to  Fri Mar 27 20:47:16.498 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

 141  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:16.753 2009  to  Fri Mar 27 20:47:16.753 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1372566e-03 -1.6379356e-03 3.1352043e-03 1.0230255e-01 8.7684631e-02 9.0860367e-02

 142  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:19.843 2009  to  Fri Mar 27 20:47:19.843 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1198521e-03 -1.0499954e-03 3.1311512e-03 9.3006134e-02 4.9118042e-02 9.0631485e-02

 143  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.098 2009  to  Fri Mar 27 20:47:20.098 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1198521e-03 -1.0499954e-03 3.1311512e-03 9.3006134e-02 4.9118042e-02 9.0631485e-02

 144  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.353 2009  to  Fri Mar 27 20:47:20.353 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

 145  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.608 2009  to  Fri Mar 27 20:47:20.608 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -7.9321861e-04 -1.0482073e-03 3.3315420e-03 4.6966553e-02 9.3727112e-02 8.0192566e-02

 146  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:20.866 2009  to  Fri Mar 27 20:47:20.866 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 147  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:21.121 2009  to  Fri Mar 27 20:47:21.121 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1439323e-03 -1.0401011e-03 3.1422377e-03 7.0003510e-02 8.8325500e-02 6.9467545e-02

 148  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:22.594 2009  to  Fri Mar 27 20:47:22.594 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

 149  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:22.851 2009  to  Fri Mar 27 20:47:22.851 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

 150  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:23.106 2009  to  Fri Mar 27 20:47:23.106 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

 151  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:24.783 2009  to  Fri Mar 27 20:47:24.783 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6493797e-03 -7.5340271e-04 3.1378269e-03 5.3947449e-02 6.1347961e-02 9.0263367e-02

 152  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:25.038 2009  to  Fri Mar 27 20:47:25.038 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1374950e-03 -1.0560751e-03 3.1458139e-03 2.4360657e-02 8.8432312e-02 9.0721130e-02

 153  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 27 20:47:25.294 2009  to  Fri Mar 27 20:47:25.294 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.1374950e-03 -1.0560751e-03 3.1458139e-03 2.4360657e-02 8.8432312e-02 9.0721130e-02

 154  FAILED    PMC        VxInterface.close                                             Fri Mar 27 20:47:37.546 2009  to  Fri Mar 27 20:47:37.546 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 155  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 20:47:37.494 2009  to  Fri Mar 27 20:47:37.494 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 156  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:13:43.159 2009  to  Fri Mar 27 21:13:43.159 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 157  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:13:43.211 2009  to  Fri Mar 27 21:13:43.211 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 158  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:22:22.710 2009  to  Fri Mar 27 21:22:22.710 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 159  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:22:22.658 2009  to  Fri Mar 27 21:22:22.658 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

 160  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:33:24.534 2009  to  Fri Mar 27 21:33:24.534 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 161  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:33:24.482 2009  to  Fri Mar 27 21:33:24.482 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 162  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:43:27.066 2009  to  Fri Mar 27 21:43:27.066 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 163  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:43:27.117 2009  to  Fri Mar 27 21:43:27.117 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 164  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:51:39.792 2009  to  Fri Mar 27 21:51:39.792 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 165  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:51:39.844 2009  to  Fri Mar 27 21:51:39.844 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 166  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 21:55:12.086 2009  to  Fri Mar 27 21:55:12.086 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 167  FAILED    PMC        VxInterface.close                                             Fri Mar 27 21:55:12.138 2009  to  Fri Mar 27 21:55:12.138 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 168  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:13:38.120 2009  to  Fri Mar 27 22:13:38.120 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 169  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:13:38.173 2009  to  Fri Mar 27 22:13:38.173 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 170  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:20:57.479 2009  to  Fri Mar 27 22:21:12.103 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 171  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:20:57.410 2009  to  Fri Mar 27 22:21:12.033 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 172  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:20:59.927 2009  to  Fri Mar 27 22:21:18.458 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 173  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:20:59.990 2009  to  Fri Mar 27 22:21:18.520 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 174  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 22:21:08.084 2009  to  Fri Mar 27 22:21:12.504 2009   (  4.42) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

 175  FAILED    PSF        command.setZernikes                                           Fri Mar 27 22:21:08.150 2009  to  Fri Mar 27 22:21:12.388 2009   (  4.24) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 176  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 22:21:08.203 2009  to  Fri Mar 27 22:21:12.333 2009   (  4.13) secs
                     right PSF ApplyZernikes failed

 177  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 22:21:08.364 2009  to  Fri Mar 27 22:21:12.278 2009   (  3.91) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 178  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:12.033 2009  to  Fri Mar 27 22:21:12.223 2009   (  0.19) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 179  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:12.103 2009  to  Fri Mar 27 22:21:12.158 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 180  FAILED    IIF        command.sendWavefront                                         Fri Mar 27 22:21:14.613 2009  to  Fri Mar 27 22:21:18.963 2009   (  4.35) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

 181  FAILED    PSF        command.applyZernikes                                         Fri Mar 27 22:21:14.734 2009  to  Fri Mar 27 22:21:18.793 2009   (  4.06) secs
                     left PSF ApplyZernikes failed

 182  FAILED    PSF        command.setZernikes                                           Fri Mar 27 22:21:14.681 2009  to  Fri Mar 27 22:21:18.849 2009   (  4.17) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 183  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 22:21:14.896 2009  to  Fri Mar 27 22:21:18.700 2009   (  3.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 184  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:18.458 2009  to  Fri Mar 27 22:21:18.643 2009   (  0.19) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 185  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:18.520 2009  to  Fri Mar 27 22:21:18.572 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 186  FAILED    IIF        command.moveFocus                                             Fri Mar 27 22:21:25.321 2009  to  Fri Mar 27 22:21:25.962 2009   (  0.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491822320601852e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 187  FAILED    IIF        command.moveFocus                                             Fri Mar 27 22:21:25.343 2009  to  Fri Mar 27 22:21:25.980 2009   (  0.64) secs
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 188  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 22:21:25.390 2009  to  Fri Mar 27 22:21:25.793 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

 189  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 27 22:21:25.408 2009  to  Fri Mar 27 22:21:25.810 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 190  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 22:21:25.443 2009  to  Fri Mar 27 22:21:25.736 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 191  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 27 22:21:25.460 2009  to  Fri Mar 27 22:21:25.755 2009   (  0.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 192  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:25.557 2009  to  Fri Mar 27 22:21:25.610 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 193  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:25.496 2009  to  Fri Mar 27 22:21:25.678 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 194  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 27 22:21:25.512 2009  to  Fri Mar 27 22:21:25.700 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 195  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 27 22:21:25.575 2009  to  Fri Mar 27 22:21:25.629 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 196  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:23:14.055 2009  to  Fri Mar 27 22:23:14.055 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 197  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:23:14.002 2009  to  Fri Mar 27 22:23:14.002 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 198  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:26:01.509 2009  to  Fri Mar 27 22:26:01.509 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 199  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:26:01.561 2009  to  Fri Mar 27 22:26:01.561 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 200  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:29:53.374 2009  to  Fri Mar 27 22:29:53.374 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 201  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:29:53.427 2009  to  Fri Mar 27 22:29:53.427 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 202  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:29:53.842 2009  to  Fri Mar 27 22:29:53.842 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 203  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:29:53.894 2009  to  Fri Mar 27 22:29:53.894 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 204  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:34:19.253 2009  to  Fri Mar 27 22:34:19.253 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 205  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:34:19.201 2009  to  Fri Mar 27 22:34:19.201 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 206  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 22:41:52.067 2009  to  Fri Mar 27 22:41:52.067 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

 207  FAILED    PMC        VxInterface.close                                             Fri Mar 27 22:41:52.120 2009  to  Fri Mar 27 22:41:52.120 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

 208  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 27 22:51:04.941 2009  to  Fri Mar 27 22:51:04.941 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 209  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 27 22:51:04.886 2009  to  Fri Mar 27 22:51:04.886 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 210  FAILED    PMC        thermal.badReceive                                            Fri Mar 27 22:51:04.994 2009  to  Fri Mar 27 22:51:04.994 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 211  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 27 23:17:34.006 2009  to  Fri Mar 27 23:17:34.006 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 212  FAILED    PMC        VxInterface.close                                             Fri Mar 27 23:17:34.060 2009  to  Fri Mar 27 23:17:34.060 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 213  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 23:55:55.950 2009  to  Fri Mar 27 23:56:01.393 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 214  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Mar 27 23:56:14.560 2009  to  Fri Mar 27 23:56:14.560 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

 215  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:08.627 2009  to  Sat Mar 28 00:03:11.550 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 216  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:11.550 2009  to  Sat Mar 28 00:03:16.590 2009   (  5.04) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 217  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 00:03:17.430 2009  to  Sat Mar 28 00:03:17.430 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

 218  FAILED    PMC        VxInterface.close                                             Sat Mar 28 00:06:53.907 2009  to  Sat Mar 28 00:06:53.907 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 219  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 28 00:06:53.855 2009  to  Sat Mar 28 00:06:53.855 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 220  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 28 00:15:21.129 2009  to  Sat Mar 28 00:15:21.129 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 221  FAILED    PMC        VxInterface.close                                             Sat Mar 28 00:15:21.182 2009  to  Sat Mar 28 00:15:21.182 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 222  FAILED    IIF        command.moveFocus                                             Sat Mar 28 01:20:46.742 2009  to  Sat Mar 28 01:20:47.504 2009   (  0.76) secs
                     IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

 223  FAILED    IIF        command.moveFocus                                             Sat Mar 28 01:20:46.743 2009  to  Sat Mar 28 01:20:47.503 2009   (  0.76) secs
                     IIF MoveFocus command started for right LBC for 6.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.300000000000000e-02

 224  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 01:20:46.803 2009  to  Sat Mar 28 01:20:47.261 2009   (  0.46) secs
                     left PSF SetInstrumentOffsets failed

 225  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 01:20:46.804 2009  to  Sat Mar 28 01:20:47.258 2009   (  0.45) secs
                     right PSF SetInstrumentOffsets failed

 226  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 01:20:46.856 2009  to  Sat Mar 28 01:20:47.205 2009   (  0.35) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 227  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 01:20:46.857 2009  to  Sat Mar 28 01:20:47.203 2009   (  0.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 228  FAILED    PMC        VxInterface.packetReadError                                   Sat Mar 28 01:30:06.266 2009  to  Sat Mar 28 01:30:06.266 2009   (  0.00) secs
                     left PMC PMCLogger packet read error: 5002

 229  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.214 2009  to  Sat Mar 28 01:30:06.214 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 230  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.620 2009  to  Sat Mar 28 01:30:06.620 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 231  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:06.976 2009  to  Sat Mar 28 01:30:06.976 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 232  FAILED    PMC        VxInterface.selectTimeout                                     Sat Mar 28 01:30:07.330 2009  to  Sat Mar 28 01:30:07.330 2009   (  0.00) secs
                     left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 233  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:28:42.846 2009  to  Sat Mar 28 02:28:52.104 2009   (  9.26) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 234  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:28:42.778 2009  to  Sat Mar 28 02:28:52.222 2009   (  9.44) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 235  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:28:42.898 2009  to  Sat Mar 28 02:28:52.047 2009   (  9.15) secs
                     right PSF ApplyZernikes failed

 236  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:28:43.059 2009  to  Sat Mar 28 02:28:51.991 2009   (  8.93) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 237  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:44:51.375 2009  to  Sat Mar 28 02:44:55.776 2009   (  4.40) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

 238  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:44:51.440 2009  to  Sat Mar 28 02:44:55.661 2009   (  4.22) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 239  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:44:51.492 2009  to  Sat Mar 28 02:44:55.606 2009   (  4.11) secs
                     right PSF ApplyZernikes failed

 240  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:44:51.653 2009  to  Sat Mar 28 02:44:55.551 2009   (  3.90) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 241  FAILED    IIF        command.sendWavefront                                         Sat Mar 28 02:44:58.138 2009  to  Sat Mar 28 02:45:02.452 2009   (  4.31) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for left LBC for M1

 242  FAILED    PSF        command.setZernikes                                           Sat Mar 28 02:44:58.203 2009  to  Sat Mar 28 02:45:02.336 2009   (  4.13) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 243  FAILED    PSF        command.applyZernikes                                         Sat Mar 28 02:44:58.256 2009  to  Sat Mar 28 02:45:02.279 2009   (  4.02) secs
                     left PSF ApplyZernikes failed

 244  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 28 02:44:58.419 2009  to  Sat Mar 28 02:45:02.221 2009   (  3.80) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 245  FAILED    IIF        command.moveFocus                                             Sat Mar 28 02:45:08.587 2009  to  Sat Mar 28 02:45:09.296 2009   (  0.71) secs
                     IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 246  FAILED    IIF        command.moveFocus                                             Sat Mar 28 02:45:08.587 2009  to  Sat Mar 28 02:45:09.370 2009   (  0.78) secs
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 247  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 02:45:08.649 2009  to  Sat Mar 28 02:45:09.050 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

 248  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 28 02:45:08.649 2009  to  Sat Mar 28 02:45:09.202 2009   (  0.55) secs
                     right PSF SetInstrumentOffsets failed

 249  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 02:45:08.702 2009  to  Sat Mar 28 02:45:08.994 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 250  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 28 02:45:08.702 2009  to  Sat Mar 28 02:45:09.146 2009   (  0.44) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 251  SHUTDOWN  PCS        shutdown                                                      Sat Mar 28 06:05:51.372 2009  to  Sat Mar 28 06:05:51.372 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

 252  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Mar 28 06:05:52.252 2009  to  Sat Mar 28 06:05:52.252 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 253  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Mar 28 06:05:52.267 2009  to  Sat Mar 28 06:05:52.267 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 254  STARTUP   PCS        startup                                                       Sat Mar 28 06:08:30.578 2009  to  Sat Mar 28 06:08:30.578 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

**********************************************************
    Reporting period ending:   Sat Mar 28 06:42:58.094 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.