You are here: Foswiki>Software Web>TCSSWReportFile_090325 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 25 2009 to Mar 26 2009
 
    Reporting period beginning:   Wed Mar 25 18:20:55.211 2009
    Reporting period ending:      Thu Mar 26 06:44:58.352 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.12    0.49    0.36    0.60   100.0 %          3          3                      
                                                                       0.12    0.49    0.36    0.60

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.13   100.0 %        123        123                      
                                                                       0.01    0.05    0.05    0.13
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.09    0.31    0.22    0.80   100.0 %        195        195                      
                                                                       0.09    0.31    0.22    0.80
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.19    0.14    0.56   100.0 %        312        312                      
                                                                       0.03    0.19    0.14    0.56
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.37    6.84    0.62   28.58    98.5 %        195        192          3           
                                                                       5.30    6.84    2.51   28.58
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    9.14    7.70    0.00   38.67   100.0 %         16         16                      
                                                                       9.27    8.80    2.04   38.67
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    9.08    7.14    0.00   38.12   100.0 %         16         16                      
                                                                       9.29    8.15    1.26   38.12
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    8.30   22.26    6.96   32.89   100.0 %          9          9                      
                                                                       8.30   22.26    6.96   32.89
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    5.85    9.65    1.26   19.09   100.0 %          9          9                      
                                                                       5.85    9.65    1.26   19.09
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    4.08    4.18    2.06   14.09   100.0 %          9          9                      
                                                                       4.08    4.18    2.06   14.09
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    6.41    6.22    0.65   70.98    99.8 %        514        513          1           
                                                                       6.42    6.22    0.65   70.98
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.78    4.45    2.53    7.56   100.0 %         40         40                      
                                                                       1.78    4.45    2.53    7.56

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            18

IIF Events of Interest

   1  STARTUP   IIF        startup                                                       Wed Mar 25 18:33:58.035 2009  to  Wed Mar 25 18:33:58.035 2009   (  0.00) secs
                     IIF subsystem started

   2  FAILED    IIF        command.moveFocus                                             Wed Mar 25 23:22:39.726 2009  to  Wed Mar 25 23:22:58.599 2009   ( 18.87) secs
                     IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

   3  FAILED    IIF        command.sendWavefront                                         Thu Mar 26 01:20:58.369 2009  to  Thu Mar 26 01:21:02.610 2009   (  4.24) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

   4  FAILED    IIF        command.moveFocus                                             Thu Mar 26 05:32:18.324 2009  to  Thu Mar 26 05:32:18.947 2009   (  0.62) secs
                     IIF MoveFocus command started for right LBC for 1.390000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

   5  FAILED    IIF        command.moveFocus                                             Thu Mar 26 05:32:18.334 2009  to  Thu Mar 26 05:32:19.028 2009   (  0.69) secs
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01

   6  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:50:51.903 2009  to  Thu Mar 26 05:51:30.866 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

   7  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:50:52.564 2009  to  Thu Mar 26 05:51:31.543 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

   8  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:51:30.866 2009  to  Thu Mar 26 05:53:18.605 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

   9  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:51:31.543 2009  to  Thu Mar 26 05:53:19.439 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

  10  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:53:24.861 2009  to  Thu Mar 26 05:53:24.861 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

  11  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:53:24.809 2009  to  Thu Mar 26 05:53:24.809 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

  12  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:53:25.106 2009  to  Thu Mar 26 05:53:25.106 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

  13  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:53:25.158 2009  to  Thu Mar 26 05:53:25.158 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.on . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3375                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6750                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 60           
 *** hydraulicBearing.badPMCData. . . . . . . . . . . . . . . . . .                 60           
     instrumentCooling.badWeatherData . . . . . . . . . . . . . . .                             2
     hydraulicBearing.badWeatherData. . . . . . . . . . . . . . . .                             2
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      96                      

ECS Events of Interest

   1  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:23:51.869 2009  to  Wed Mar 25 18:23:51.869 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   2  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:23:51.921 2009  to  Wed Mar 25 18:23:51.921 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   3  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:02.060 2009  to  Wed Mar 25 18:24:02.060 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   4  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:02.008 2009  to  Wed Mar 25 18:24:02.008 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   5  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:12.151 2009  to  Wed Mar 25 18:24:12.151 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   6  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:12.203 2009  to  Wed Mar 25 18:24:12.203 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:22.294 2009  to  Wed Mar 25 18:24:22.294 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:22.345 2009  to  Wed Mar 25 18:24:22.345 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   9  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:32.491 2009  to  Wed Mar 25 18:24:32.491 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:32.438 2009  to  Wed Mar 25 18:24:32.438 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  11  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:42.582 2009  to  Wed Mar 25 18:24:42.582 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  12  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:42.633 2009  to  Wed Mar 25 18:24:42.633 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  13  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:52.772 2009  to  Wed Mar 25 18:24:52.772 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:52.720 2009  to  Wed Mar 25 18:24:52.720 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:02.864 2009  to  Wed Mar 25 18:25:02.864 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:02.917 2009  to  Wed Mar 25 18:25:02.917 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:13.007 2009  to  Wed Mar 25 18:25:13.007 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  18  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:13.059 2009  to  Wed Mar 25 18:25:13.059 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  19  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:23.213 2009  to  Wed Mar 25 18:25:23.213 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  20  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:23.160 2009  to  Wed Mar 25 18:25:23.160 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  21  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:33.304 2009  to  Wed Mar 25 18:25:33.304 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  22  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:33.356 2009  to  Wed Mar 25 18:25:33.356 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  23  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:43.499 2009  to  Wed Mar 25 18:25:43.499 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  24  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:43.447 2009  to  Wed Mar 25 18:25:43.447 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  25  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:53.591 2009  to  Wed Mar 25 18:25:53.591 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  26  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:53.643 2009  to  Wed Mar 25 18:25:53.643 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  27  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:03.734 2009  to  Wed Mar 25 18:26:03.734 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  28  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:03.786 2009  to  Wed Mar 25 18:26:03.786 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  29  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:13.930 2009  to  Wed Mar 25 18:26:13.930 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  30  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:13.878 2009  to  Wed Mar 25 18:26:13.878 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  31  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:24.021 2009  to  Wed Mar 25 18:26:24.021 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  32  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:24.073 2009  to  Wed Mar 25 18:26:24.073 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  33  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:34.217 2009  to  Wed Mar 25 18:26:34.217 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  34  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:34.165 2009  to  Wed Mar 25 18:26:34.165 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  35  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:44.307 2009  to  Wed Mar 25 18:26:44.307 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  36  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:44.358 2009  to  Wed Mar 25 18:26:44.358 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  37  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:54.452 2009  to  Wed Mar 25 18:26:54.452 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  38  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:54.500 2009  to  Wed Mar 25 18:26:54.500 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  39  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:04.625 2009  to  Wed Mar 25 18:27:04.625 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  40  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:04.573 2009  to  Wed Mar 25 18:27:04.573 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  41  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:14.719 2009  to  Wed Mar 25 18:27:14.719 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  42  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:14.771 2009  to  Wed Mar 25 18:27:14.771 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  43  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:24.865 2009  to  Wed Mar 25 18:27:24.865 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  44  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:24.917 2009  to  Wed Mar 25 18:27:24.917 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  45  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:35.062 2009  to  Wed Mar 25 18:27:35.062 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  46  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:35.010 2009  to  Wed Mar 25 18:27:35.010 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  47  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:45.152 2009  to  Wed Mar 25 18:27:45.152 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  48  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:45.204 2009  to  Wed Mar 25 18:27:45.204 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  49  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:55.348 2009  to  Wed Mar 25 18:27:55.348 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  50  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:55.296 2009  to  Wed Mar 25 18:27:55.296 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest

   1  STARTUP   ENV        startup                                                       Wed Mar 25 19:19:36.834 2009  to  Wed Mar 25 19:19:36.834 2009   (  0.00) secs
                     ENV subsystem started, version 1.0
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      19                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      10                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Wed Mar 25 18:20:55.211 2009  to  Wed Mar 25 18:20:55.211 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           195
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      77                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      63                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     179                      
     MCSPU.Tracker.unexpectedVelMode. . . . . . . . . . . . . . . .                  5           
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      42                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            79
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            46
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      90                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     323                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .      19                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      76                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .     144                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .     144                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      67                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      84                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            13
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       6                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      90                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 14           
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      72                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      12                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 48           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     810                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     274                      
     MCSPU.ELDrive.velocityNotZero. . . . . . . . . . . . . . . . .                  8           
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.ELDrive.torqueLimit. . . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.BrakeFailSet2. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  3           
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:38:30.129 2009  to  Wed Mar 25 18:38:30.129 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

   2  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed Mar 25 18:39:07.856 2009  to  Wed Mar 25 18:39:07.856 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   3  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:13.229 2009  to  Wed Mar 25 18:40:13.229 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   4  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:20.908 2009  to  Wed Mar 25 18:40:20.908 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:29.011 2009  to  Wed Mar 25 18:40:29.011 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:40:56.200 2009  to  Wed Mar 25 18:40:56.200 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:40:56.267 2009  to  Wed Mar 25 18:40:56.267 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:08:41.965 2009  to  Wed Mar 25 19:08:41.965 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:08:41.972 2009  to  Wed Mar 25 19:08:41.972 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  10  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 19:08:42.061 2009  to  Wed Mar 25 19:08:42.061 2009   (  0.00) secs
                     drive cabinet has turned on.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.083 2009  to  Wed Mar 25 19:08:43.083 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.085 2009  to  Wed Mar 25 19:08:43.085 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:11:00.830 2009  to  Wed Mar 25 19:11:00.830 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:11:00.830 2009  to  Wed Mar 25 19:11:00.830 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 19:14:30.766 2009  to  Wed Mar 25 19:14:30.766 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 19:14:30.787 2009  to  Wed Mar 25 19:14:30.787 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:15:37.341 2009  to  Wed Mar 25 20:15:37.341 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:15:37.349 2009  to  Wed Mar 25 20:15:37.349 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:15:37.447 2009  to  Wed Mar 25 20:15:37.447 2009   (  0.00) secs
                     drive cabinet has turned on.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.460 2009  to  Wed Mar 25 20:15:38.460 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.460 2009  to  Wed Mar 25 20:15:38.460 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.461 2009  to  Wed Mar 25 20:15:38.461 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.461 2009  to  Wed Mar 25 20:15:38.461 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.462 2009  to  Wed Mar 25 20:15:38.462 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.462 2009  to  Wed Mar 25 20:15:38.462 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.463 2009  to  Wed Mar 25 20:15:38.463 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.463 2009  to  Wed Mar 25 20:15:38.463 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:30:45.692 2009  to  Wed Mar 25 20:30:45.692 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:30:45.697 2009  to  Wed Mar 25 20:30:45.697 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:30:45.798 2009  to  Wed Mar 25 20:30:45.798 2009   (  0.00) secs
                     drive cabinet has turned on.

  37  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.823 2009  to  Wed Mar 25 20:30:46.823 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  38  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.823 2009  to  Wed Mar 25 20:30:46.823 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  39  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.824 2009  to  Wed Mar 25 20:30:46.824 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  40  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.824 2009  to  Wed Mar 25 20:30:46.824 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  41  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.825 2009  to  Wed Mar 25 20:30:46.825 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  42  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.825 2009  to  Wed Mar 25 20:30:46.825 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.826 2009  to  Wed Mar 25 20:30:46.826 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.827 2009  to  Wed Mar 25 20:30:46.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:35:03.986 2009  to  Wed Mar 25 20:35:03.986 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:35:03.988 2009  to  Wed Mar 25 20:35:03.988 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:35:04.079 2009  to  Wed Mar 25 20:35:04.079 2009   (  0.00) secs
                     drive cabinet has turned on.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:35:05.106 2009  to  Wed Mar 25 20:35:05.106 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:41:01.239 2009  to  Wed Mar 25 22:41:01.239 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:41:01.246 2009  to  Wed Mar 25 22:41:01.246 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 22:41:01.344 2009  to  Wed Mar 25 22:41:01.344 2009   (  0.00) secs
                     drive cabinet has turned on.

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:46:17.153 2009  to  Wed Mar 25 22:46:17.153 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  53  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:46:17.158 2009  to  Wed Mar 25 22:46:17.158 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  54  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 22:46:17.251 2009  to  Wed Mar 25 22:46:17.251 2009   (  0.00) secs
                     drive cabinet has turned on.

  55  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 26 03:17:48.926 2009  to  Thu Mar 26 03:17:48.926 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  56  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:18:03.842 2009  to  Thu Mar 26 03:18:03.842 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  57  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:18:54.912 2009  to  Thu Mar 26 03:18:54.912 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  58  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Thu Mar 26 03:39:25.179 2009  to  Thu Mar 26 03:39:25.179 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  59  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Thu Mar 26 03:39:25.179 2009  to  Thu Mar 26 03:39:25.179 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

  60  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:40:21.803 2009  to  Thu Mar 26 03:40:21.803 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  61  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:41:16.911 2009  to  Thu Mar 26 03:41:16.911 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  62  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:45:25.442 2009  to  Thu Mar 26 03:45:25.442 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  63  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 26 03:54:42.706 2009  to  Thu Mar 26 03:54:42.706 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  64  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:55:50.247 2009  to  Thu Mar 26 03:55:50.247 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  65  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:55:50.899 2009  to  Thu Mar 26 03:55:50.899 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  66  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:55:50.899 2009  to  Thu Mar 26 03:55:50.899 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  67  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:56:10.081 2009  to  Thu Mar 26 03:56:10.081 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  68  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:57:46.366 2009  to  Thu Mar 26 03:57:46.366 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  69  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 04:01:04.703 2009  to  Thu Mar 26 04:01:04.703 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

  70  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Thu Mar 26 06:10:17.779 2009  to  Thu Mar 26 06:10:17.779 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  71  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Thu Mar 26 06:10:23.942 2009  to  Thu Mar 26 06:10:23.942 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  72  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Thu Mar 26 06:10:23.942 2009  to  Thu Mar 26 06:10:23.942 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             1

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Wed Mar 25 19:20:31.683 2009  to  Wed Mar 25 19:20:31.683 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.15   100.0 %        312        312                      
                                                                       0.01    0.06    0.04    0.15
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.13    0.11    0.20   100.0 %        195        195                      
                                                                       0.02    0.13    0.11    0.20
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.12    0.31    0.06    0.49   100.0 %         16         16                      
                                                                       0.12    0.31    0.06    0.49
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.04    0.08    0.05    0.17   100.0 %         32         32                      
                                                                       0.04    0.08    0.05    0.17
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.05    0.09    0.05    0.12   100.0 %          2          2                      
                                                                       0.05    0.09    0.05    0.12
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.59    0.31    0.82    96.9 %         32         30          1           
                                                                       0.20    0.59    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.01    0.09    0.08    0.11   100.0 %          3          3                      
                                                                       0.01    0.09    0.08    0.11

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       3                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       3                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Wed Mar 25 18:21:30.418 2009  to  Wed Mar 25 18:21:30.418 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   2  FAILED    PCS        telescope.command.startTracking                               Wed Mar 25 18:38:26.215 2009  to  Wed Mar 25 18:38:27.027 2009   (  0.81) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! EL axis not in EL_READY state.

   3  SHUTDOWN  PCS        shutdown                                                      Wed Mar 25 19:10:59.922 2009  to  Wed Mar 25 19:10:59.922 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

   4  STARTUP   PCS        startup                                                       Wed Mar 25 19:11:14.622 2009  to  Wed Mar 25 19:11:14.622 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   5  SEQERROR  PCS        telescope.command.startTracking                               Thu Mar 26 05:30:33.170 2009  to  Thu Mar 26 05:31:12.865 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.71    0.55    0.05    1.05    50.0 %          2          1          1           
                                                                       0.00    1.05    1.05    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.68    3.54    2.04    6.07   100.0 %        126        126                      
                                                                       1.68    3.54    2.04    6.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.23    2.56    2.05    5.06   100.0 %          6          6                      
                                                                       1.23    2.56    2.05    5.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.05    5.05    5.05   100.0 %          1          1                      
                                                                       0.00    5.05    5.05    5.05
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.18   66.18   66.18   100.0 %          1          1                      
                                                                       0.00   66.18   66.18   66.18
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    9.45    5.79    0.00  190.43    98.8 %        756        747          9           
                                                                       6.36    5.51    2.05   99.25
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  389.03  389.03  389.03   100.0 %          1          1                      
                                                                       0.00  389.03  389.03  389.03
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.09    0.09    0.09   100.0 %          1          1                      
                                                                       0.00    0.09    0.09    0.09
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.05    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      45                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       2                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       2                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      19                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      19                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            24
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                             9
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       6                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           211
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           210
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           322
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     126                      
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             4
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            23
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 25           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 25           
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           

PMC Events of Interest

   1  FAILED    PMC        actuator.telemetryError                                       Wed Mar 25 19:20:45.427 2009  to  Wed Mar 25 19:20:45.427 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   2  STARTUP   PMC        startup                                                       Wed Mar 25 19:20:48.473 2009  to  Wed Mar 25 19:20:48.473 2009   (  0.00) secs
                     left PMC subsystem started, version 4.7

   3  FAILED    PMC        actuator.telemetryError                                       Wed Mar 25 19:20:53.891 2009  to  Wed Mar 25 19:20:53.891 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   4  STARTUP   PMC        startup                                                       Wed Mar 25 19:20:58.057 2009  to  Wed Mar 25 19:20:58.057 2009   (  0.00) secs
                     right PMC subsystem started, version 4.7

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:05:57.107 2009  to  Wed Mar 25 22:09:07.541 2009   (190.43) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:09:23.680 2009  to  Wed Mar 25 22:10:22.844 2009   ( 59.16) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        mirror.panic                                                  Wed Mar 25 22:10:22.327 2009  to  Wed Mar 25 22:10:22.327 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:10:40.094 2009  to  Wed Mar 25 22:10:40.147 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   9  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 22:12:45.138 2009  to  Wed Mar 25 22:12:45.191 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  10  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 22:52:07.230 2009  to  Wed Mar 25 22:52:07.230 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Wed Mar 25 22:52:07.282 2009  to  Wed Mar 25 22:52:07.282 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.close                                             Wed Mar 25 22:52:34.978 2009  to  Wed Mar 25 22:52:34.978 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 22:52:34.926 2009  to  Wed Mar 25 22:52:34.926 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 23:22:39.978 2009  to  Wed Mar 25 23:22:58.065 2009   ( 18.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:22:53.960 2009  to  Wed Mar 25 23:22:53.960 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:22:53.908 2009  to  Wed Mar 25 23:22:53.908 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:32:22.824 2009  to  Wed Mar 25 23:32:22.824 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:32:22.771 2009  to  Wed Mar 25 23:32:22.771 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  19  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:36:17.987 2009  to  Wed Mar 25 23:36:17.987 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:36:17.936 2009  to  Wed Mar 25 23:36:17.936 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:53:48.629 2009  to  Wed Mar 25 23:53:48.629 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:53:48.577 2009  to  Wed Mar 25 23:53:48.577 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Thu Mar 26 00:04:58.227 2009  to  Thu Mar 26 00:04:58.227 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  24  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 00:04:58.175 2009  to  Thu Mar 26 00:04:58.175 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  25  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:03:58.647 2009  to  Thu Mar 26 01:03:58.647 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:03:58.699 2009  to  Thu Mar 26 01:03:58.699 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  27  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:12:33.223 2009  to  Thu Mar 26 01:12:33.223 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:12:33.170 2009  to  Thu Mar 26 01:12:33.170 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:13:07.718 2009  to  Thu Mar 26 01:13:07.718 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:13:07.666 2009  to  Thu Mar 26 01:13:07.666 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  31  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:20:53.147 2009  to  Thu Mar 26 01:21:02.080 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  32  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:21:02.080 2009  to  Thu Mar 26 01:21:02.133 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  33  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:21:03.217 2009  to  Thu Mar 26 01:21:03.217 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:28:42.261 2009  to  Thu Mar 26 01:28:42.261 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:28:42.313 2009  to  Thu Mar 26 01:28:42.313 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:39:03.767 2009  to  Thu Mar 26 01:39:03.767 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:39:03.819 2009  to  Thu Mar 26 01:39:03.819 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:57:32.199 2009  to  Thu Mar 26 01:57:32.199 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:57:32.251 2009  to  Thu Mar 26 01:57:32.251 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:58:03.216 2009  to  Thu Mar 26 01:58:03.216 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:58:03.164 2009  to  Thu Mar 26 01:58:03.164 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:00:20.326 2009  to  Thu Mar 26 02:00:20.326 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:00:20.273 2009  to  Thu Mar 26 02:00:20.273 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:09:18.692 2009  to  Thu Mar 26 02:09:18.692 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:09:18.744 2009  to  Thu Mar 26 02:09:18.744 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:31:51.462 2009  to  Thu Mar 26 02:31:51.462 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  47  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:31:51.513 2009  to  Thu Mar 26 02:31:51.513 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  48  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 26 02:34:08.281 2009  to  Thu Mar 26 02:34:08.281 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  49  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 26 02:34:08.333 2009  to  Thu Mar 26 02:34:08.333 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  50  FAILED    PMC        thermal.badReceive                                            Thu Mar 26 02:34:08.386 2009  to  Thu Mar 26 02:34:08.386 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  51  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:38:59.550 2009  to  Thu Mar 26 02:38:59.550 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:38:59.498 2009  to  Thu Mar 26 02:38:59.498 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Thu Mar 26 03:00:15.681 2009  to  Thu Mar 26 03:00:15.681 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 03:00:15.628 2009  to  Thu Mar 26 03:00:15.628 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 03:05:46.578 2009  to  Thu Mar 26 03:05:46.578 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Thu Mar 26 03:05:46.630 2009  to  Thu Mar 26 03:05:46.630 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:14:41.854 2009  to  Thu Mar 26 04:14:41.854 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  58  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:14:41.906 2009  to  Thu Mar 26 04:14:41.906 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  59  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:17:55.777 2009  to  Thu Mar 26 04:17:55.777 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:17:55.724 2009  to  Thu Mar 26 04:17:55.724 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:24:37.615 2009  to  Thu Mar 26 04:24:37.615 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:24:37.563 2009  to  Thu Mar 26 04:24:37.563 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:26:39.935 2009  to  Thu Mar 26 04:26:39.935 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:26:39.987 2009  to  Thu Mar 26 04:26:39.987 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  65  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:09.879 2009  to  Thu Mar 26 05:32:18.550 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:11.296 2009  to  Thu Mar 26 05:32:18.568 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:18.550 2009  to  Thu Mar 26 05:32:18.603 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:18.568 2009  to  Thu Mar 26 05:32:18.620 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:55.436 2009  to  Thu Mar 26 05:32:55.436 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  70  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:58.026 2009  to  Thu Mar 26 05:32:58.026 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  71  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 26 05:35:45.956 2009  to  Thu Mar 26 05:35:45.956 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  72  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 26 05:35:46.008 2009  to  Thu Mar 26 05:35:46.008 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  73  FAILED    PMC        thermal.badReceive                                            Thu Mar 26 05:35:46.061 2009  to  Thu Mar 26 05:35:46.061 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  74  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 05:44:51.535 2009  to  Thu Mar 26 05:44:51.535 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  75  FAILED    PMC        VxInterface.close                                             Thu Mar 26 05:44:51.587 2009  to  Thu Mar 26 05:44:51.587 2009   (  0.00) secs
                     left PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    6.41    5.97    0.41   70.72    99.8 %        514        513          1           
                                                                       6.42    5.97    0.41   70.72
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.02    0.06    0.05    0.11   100.0 %         18         18                      
                                                                       0.02    0.06    0.05    0.11
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.03    6.30    0.39   28.45    98.7 %        235        232          3           
                                                                       4.96    6.29    2.38   28.45
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    6.41    6.08    0.52   70.84    99.8 %        514        513          1           
                                                                       6.42    6.08    0.52   70.84
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.64    5.87    0.00   70.50    99.6 %        523        521          2           
                                                                       6.65    5.90    0.19   70.50
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    9.46    5.92    0.00  190.56    98.8 %        756        747          9           
                                                                       6.36    5.64    2.17   99.39
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.18    3.05    2.17    5.19   100.0 %          6          6                      
                                                                       1.18    3.05    2.17    5.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.16    0.11    0.06    1.62   100.0 %        186        186                      
                                                                       0.16    0.11    0.06    1.62
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.33    0.32    0.06    0.75     0.0 %          4                     4           
                                                                                                   
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.42    1.76    1.46    2.05   100.0 %          2          2                      
                                                                       0.42    1.76    1.46    2.05
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   68.23  100.23   38.61  194.53    75.0 %          4          3          1           
                                                                      32.45   68.79   38.61  103.11
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.03    6.19    0.29   28.35    98.7 %        235        232          3           
                                                                       4.96    6.18    2.28   28.35
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %         11         11                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.05    0.04    0.13   100.0 %        525        525                      
                                                                       0.01    0.05    0.04    0.13
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.13    1.46    1.37    1.55   100.0 %          2          2                      
                                                                       0.13    1.46    1.37    1.55
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.15    1.32    1.21    1.43   100.0 %          2          2                      
                                                                       0.15    1.32    1.21    1.43
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.01    0.11    0.10    0.11   100.0 %          2          2                      
                                                                       0.01    0.11    0.10    0.11
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.06    0.92    0.88    0.96   100.0 %          2          2                      
                                                                       0.06    0.92    0.88    0.96

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               6208           

PSF Events of Interest

   1  STARTUP   PSF        startup                                                       Wed Mar 25 19:21:10.140 2009  to  Wed Mar 25 19:21:10.140 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 19:21:15.213 2009  to  Wed Mar 25 19:21:15.644 2009   (  0.43) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  STARTUP   PSF        startup                                                       Wed Mar 25 19:21:18.313 2009  to  Wed Mar 25 19:21:18.313 2009   (  0.00) secs
                     right PSF subsystem started, version 4.32

   4  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 19:21:23.654 2009  to  Wed Mar 25 19:21:24.403 2009   (  0.75) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   5  FAILED    PSF        primaryMirror.command.revert                                  Wed Mar 25 22:05:53.140 2009  to  Wed Mar 25 22:09:07.673 2009   (194.53) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:05:57.044 2009  to  Wed Mar 25 22:09:07.609 2009   (190.56) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   7  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 22:08:15.285 2009  to  Wed Mar 25 22:08:15.341 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:09:23.618 2009  to  Wed Mar 25 22:10:22.911 2009   ( 59.29) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   9  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 22:10:34.507 2009  to  Wed Mar 25 22:10:34.564 2009   (  0.06) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:10:40.031 2009  to  Wed Mar 25 22:10:40.236 2009   (  0.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  11  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 23:22:39.790 2009  to  Wed Mar 25 23:22:58.379 2009   ( 18.59) secs
                     right PSF SetInstrumentOffsets failed

  12  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 23:22:39.842 2009  to  Wed Mar 25 23:22:58.323 2009   ( 18.48) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 23:22:39.894 2009  to  Wed Mar 25 23:22:58.267 2009   ( 18.37) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:20:48.213 2009  to  Thu Mar 26 01:20:58.738 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

  15  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:20:53.082 2009  to  Thu Mar 26 01:21:02.012 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  FAILED    PSF        command.applyZernikes                                         Thu Mar 26 01:20:58.576 2009  to  Thu Mar 26 01:21:02.413 2009   (  3.84) secs
                     right PSF ApplyZernikes failed

  17  FAILED    PSF        command.setZernikes                                           Thu Mar 26 01:20:58.524 2009  to  Thu Mar 26 01:21:02.490 2009   (  3.97) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  18  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:20:58.738 2009  to  Thu Mar 26 01:21:02.351 2009   (  3.61) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  19  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:21:02.012 2009  to  Thu Mar 26 01:21:02.295 2009   (  0.28) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  20  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:21:03.338 2009  to  Thu Mar 26 01:21:03.338 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:21:03.277 2009  to  Thu Mar 26 01:21:03.277 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:23:31.785 2009  to  Thu Mar 26 01:23:37.848 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

  23  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:23:51.295 2009  to  Thu Mar 26 01:23:51.295 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

  24  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.186 2009  to  Thu Mar 26 04:52:11.186 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.442 2009  to  Thu Mar 26 04:52:11.442 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.723 2009  to  Thu Mar 26 04:52:11.723 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.181 2009  to  Thu Mar 26 04:52:12.181 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.436 2009  to  Thu Mar 26 04:52:12.436 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.691 2009  to  Thu Mar 26 04:52:12.691 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:16.802 2009  to  Thu Mar 26 04:52:16.802 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:18.073 2009  to  Thu Mar 26 04:52:18.073 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:18.331 2009  to  Thu Mar 26 04:52:18.331 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:19.604 2009  to  Thu Mar 26 04:52:19.604 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3167858e-03 -1.2088716e-03 3.1179190e-03 8.2476616e-02 5.8826447e-02 4.0385008e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:19.860 2009  to  Thu Mar 26 04:52:19.860 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3167858e-03 -1.2088716e-03 3.1179190e-03 8.2476616e-02 5.8826447e-02 4.0385008e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:20.116 2009  to  Thu Mar 26 04:52:20.116 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:20.365 2009  to  Thu Mar 26 04:52:20.365 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:21.026 2009  to  Thu Mar 26 04:52:21.026 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:21.282 2009  to  Thu Mar 26 04:52:21.282 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.345 2009  to  Thu Mar 26 04:52:22.345 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.599 2009  to  Thu Mar 26 04:52:22.599 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.853 2009  to  Thu Mar 26 04:52:22.853 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:23.511 2009  to  Thu Mar 26 04:52:23.511 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:23.765 2009  to  Thu Mar 26 04:52:23.765 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:24.826 2009  to  Thu Mar 26 04:52:24.826 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.080 2009  to  Thu Mar 26 04:52:25.080 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.334 2009  to  Thu Mar 26 04:52:25.334 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.588 2009  to  Thu Mar 26 04:52:25.588 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5022755e-03 -9.0387464e-04 3.3105612e-03 6.5997124e-02 7.6381683e-02 2.9471159e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.842 2009  to  Thu Mar 26 04:52:25.842 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

  49  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:09.780 2009  to  Thu Mar 26 05:32:18.490 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  50  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:11.229 2009  to  Thu Mar 26 05:32:18.503 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  FAILED    PSF        command.setInstrumentOffsets                                  Thu Mar 26 05:32:18.385 2009  to  Thu Mar 26 05:32:18.780 2009   (  0.39) secs
                     left PSF SetInstrumentOffsets failed

  52  FAILED    PSF        command.setInstrumentOffsets                                  Thu Mar 26 05:32:18.398 2009  to  Thu Mar 26 05:32:18.854 2009   (  0.46) secs
                     right PSF SetInstrumentOffsets failed

  53  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:18.490 2009  to  Thu Mar 26 05:32:18.670 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:18.503 2009  to  Thu Mar 26 05:32:18.739 2009   (  0.24) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Mar 26 05:32:18.438 2009  to  Thu Mar 26 05:32:18.725 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  56  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Mar 26 05:32:18.451 2009  to  Thu Mar 26 05:32:18.798 2009   (  0.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  57  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:55.500 2009  to  Thu Mar 26 05:32:55.500 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:58.093 2009  to  Thu Mar 26 05:32:58.093 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  STARTUP   LSS        startup                                                       Wed Mar 25 18:20:55.211 2009  to  Wed Mar 25 18:20:55.211 2009   (  0.00) secs
                     The LSS was started.

   2  STARTUP   PCS        startup                                                       Wed Mar 25 18:21:30.418 2009  to  Wed Mar 25 18:21:30.418 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:23:51.869 2009  to  Wed Mar 25 18:23:51.869 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   4  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:23:51.921 2009  to  Wed Mar 25 18:23:51.921 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   5  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:02.060 2009  to  Wed Mar 25 18:24:02.060 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:02.008 2009  to  Wed Mar 25 18:24:02.008 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:12.151 2009  to  Wed Mar 25 18:24:12.151 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:12.203 2009  to  Wed Mar 25 18:24:12.203 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   9  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:22.294 2009  to  Wed Mar 25 18:24:22.294 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  10  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:22.345 2009  to  Wed Mar 25 18:24:22.345 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  11  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:32.491 2009  to  Wed Mar 25 18:24:32.491 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  12  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:32.438 2009  to  Wed Mar 25 18:24:32.438 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  13  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:42.582 2009  to  Wed Mar 25 18:24:42.582 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  14  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:42.633 2009  to  Wed Mar 25 18:24:42.633 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  15  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:24:52.772 2009  to  Wed Mar 25 18:24:52.772 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  16  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:24:52.720 2009  to  Wed Mar 25 18:24:52.720 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  17  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:02.864 2009  to  Wed Mar 25 18:25:02.864 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  18  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:02.917 2009  to  Wed Mar 25 18:25:02.917 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  19  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:13.007 2009  to  Wed Mar 25 18:25:13.007 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  20  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:13.059 2009  to  Wed Mar 25 18:25:13.059 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  21  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:23.213 2009  to  Wed Mar 25 18:25:23.213 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  22  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:23.160 2009  to  Wed Mar 25 18:25:23.160 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  23  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:33.304 2009  to  Wed Mar 25 18:25:33.304 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  24  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:33.356 2009  to  Wed Mar 25 18:25:33.356 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  25  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:43.499 2009  to  Wed Mar 25 18:25:43.499 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  26  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:43.447 2009  to  Wed Mar 25 18:25:43.447 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  27  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:25:53.591 2009  to  Wed Mar 25 18:25:53.591 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  28  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:25:53.643 2009  to  Wed Mar 25 18:25:53.643 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  29  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:03.734 2009  to  Wed Mar 25 18:26:03.734 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  30  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:03.786 2009  to  Wed Mar 25 18:26:03.786 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  31  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:13.930 2009  to  Wed Mar 25 18:26:13.930 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  32  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:13.878 2009  to  Wed Mar 25 18:26:13.878 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  33  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:24.021 2009  to  Wed Mar 25 18:26:24.021 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  34  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:24.073 2009  to  Wed Mar 25 18:26:24.073 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  35  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:34.217 2009  to  Wed Mar 25 18:26:34.217 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  36  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:34.165 2009  to  Wed Mar 25 18:26:34.165 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  37  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:44.307 2009  to  Wed Mar 25 18:26:44.307 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  38  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:44.358 2009  to  Wed Mar 25 18:26:44.358 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  39  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:26:54.452 2009  to  Wed Mar 25 18:26:54.452 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  40  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:26:54.500 2009  to  Wed Mar 25 18:26:54.500 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  41  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:04.625 2009  to  Wed Mar 25 18:27:04.625 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  42  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:04.573 2009  to  Wed Mar 25 18:27:04.573 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  43  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:14.719 2009  to  Wed Mar 25 18:27:14.719 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  44  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:14.771 2009  to  Wed Mar 25 18:27:14.771 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  45  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:24.865 2009  to  Wed Mar 25 18:27:24.865 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  46  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:24.917 2009  to  Wed Mar 25 18:27:24.917 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  47  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:35.062 2009  to  Wed Mar 25 18:27:35.062 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  48  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:35.010 2009  to  Wed Mar 25 18:27:35.010 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  49  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:45.152 2009  to  Wed Mar 25 18:27:45.152 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  50  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:45.204 2009  to  Wed Mar 25 18:27:45.204 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  51  FAILED    ECS        hydraulicBearing.badPMCData                                   Wed Mar 25 18:27:55.348 2009  to  Wed Mar 25 18:27:55.348 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  52  FAILED    ECS        instrumentCooling.badPMCData                                  Wed Mar 25 18:27:55.296 2009  to  Wed Mar 25 18:27:55.296 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  53  STARTUP   IIF        startup                                                       Wed Mar 25 18:33:58.035 2009  to  Wed Mar 25 18:33:58.035 2009   (  0.00) secs
                     IIF subsystem started

  54  FAILED    PCS        telescope.command.startTracking                               Wed Mar 25 18:38:26.215 2009  to  Wed Mar 25 18:38:27.027 2009   (  0.81) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR Cmd. ignored! EL axis not in EL_READY state.

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:38:30.129 2009  to  Wed Mar 25 18:38:30.129 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  56  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed Mar 25 18:39:07.856 2009  to  Wed Mar 25 18:39:07.856 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  57  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:13.229 2009  to  Wed Mar 25 18:40:13.229 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  58  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:20.908 2009  to  Wed Mar 25 18:40:20.908 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  59  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Wed Mar 25 18:40:29.011 2009  to  Wed Mar 25 18:40:29.011 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:40:56.200 2009  to  Wed Mar 25 18:40:56.200 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 18:40:56.267 2009  to  Wed Mar 25 18:40:56.267 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:08:41.965 2009  to  Wed Mar 25 19:08:41.965 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:08:41.972 2009  to  Wed Mar 25 19:08:41.972 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 19:08:42.061 2009  to  Wed Mar 25 19:08:42.061 2009   (  0.00) secs
                     drive cabinet has turned on.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.083 2009  to  Wed Mar 25 19:08:43.083 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.084 2009  to  Wed Mar 25 19:08:43.084 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.085 2009  to  Wed Mar 25 19:08:43.085 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 19:08:43.086 2009  to  Wed Mar 25 19:08:43.086 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  SHUTDOWN  PCS        shutdown                                                      Wed Mar 25 19:10:59.922 2009  to  Wed Mar 25 19:10:59.922 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:11:00.830 2009  to  Wed Mar 25 19:11:00.830 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 19:11:00.830 2009  to  Wed Mar 25 19:11:00.830 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  76  STARTUP   PCS        startup                                                       Wed Mar 25 19:11:14.622 2009  to  Wed Mar 25 19:11:14.622 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 19:14:30.766 2009  to  Wed Mar 25 19:14:30.766 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  78  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Wed Mar 25 19:14:30.787 2009  to  Wed Mar 25 19:14:30.787 2009   (  0.00) secs
                     The EL Servo DSP changed to Velocity mode unexpectedly.

  79  STARTUP   ENV        startup                                                       Wed Mar 25 19:19:36.834 2009  to  Wed Mar 25 19:19:36.834 2009   (  0.00) secs
                     ENV subsystem started, version 1.0

  80  STARTUP   OSS        startup                                                       Wed Mar 25 19:20:31.683 2009  to  Wed Mar 25 19:20:31.683 2009   (  0.00) secs
                     The oss was started.

  81  FAILED    PMC        actuator.telemetryError                                       Wed Mar 25 19:20:45.427 2009  to  Wed Mar 25 19:20:45.427 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  82  STARTUP   PMC        startup                                                       Wed Mar 25 19:20:48.473 2009  to  Wed Mar 25 19:20:48.473 2009   (  0.00) secs
                     left PMC subsystem started, version 4.7

  83  FAILED    PMC        actuator.telemetryError                                       Wed Mar 25 19:20:53.891 2009  to  Wed Mar 25 19:20:53.891 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  84  STARTUP   PMC        startup                                                       Wed Mar 25 19:20:58.057 2009  to  Wed Mar 25 19:20:58.057 2009   (  0.00) secs
                     right PMC subsystem started, version 4.7

  85  STARTUP   PSF        startup                                                       Wed Mar 25 19:21:10.140 2009  to  Wed Mar 25 19:21:10.140 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

  86  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 19:21:15.213 2009  to  Wed Mar 25 19:21:15.644 2009   (  0.43) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  87  STARTUP   PSF        startup                                                       Wed Mar 25 19:21:18.313 2009  to  Wed Mar 25 19:21:18.313 2009   (  0.00) secs
                     right PSF subsystem started, version 4.32

  88  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 19:21:23.654 2009  to  Wed Mar 25 19:21:24.403 2009   (  0.75) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:15:37.341 2009  to  Wed Mar 25 20:15:37.341 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:15:37.349 2009  to  Wed Mar 25 20:15:37.349 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  91  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:15:37.447 2009  to  Wed Mar 25 20:15:37.447 2009   (  0.00) secs
                     drive cabinet has turned on.

  92  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.460 2009  to  Wed Mar 25 20:15:38.460 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  93  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.460 2009  to  Wed Mar 25 20:15:38.460 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  94  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.461 2009  to  Wed Mar 25 20:15:38.461 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  95  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.461 2009  to  Wed Mar 25 20:15:38.461 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  96  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.462 2009  to  Wed Mar 25 20:15:38.462 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  97  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.462 2009  to  Wed Mar 25 20:15:38.462 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  98  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.463 2009  to  Wed Mar 25 20:15:38.463 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  99  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:15:38.463 2009  to  Wed Mar 25 20:15:38.463 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 100  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:30:45.692 2009  to  Wed Mar 25 20:30:45.692 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:30:45.697 2009  to  Wed Mar 25 20:30:45.697 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 102  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:30:45.798 2009  to  Wed Mar 25 20:30:45.798 2009   (  0.00) secs
                     drive cabinet has turned on.

 103  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.823 2009  to  Wed Mar 25 20:30:46.823 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 104  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.823 2009  to  Wed Mar 25 20:30:46.823 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 105  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.824 2009  to  Wed Mar 25 20:30:46.824 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 106  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.824 2009  to  Wed Mar 25 20:30:46.824 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 107  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.825 2009  to  Wed Mar 25 20:30:46.825 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 108  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.825 2009  to  Wed Mar 25 20:30:46.825 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 109  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.826 2009  to  Wed Mar 25 20:30:46.826 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 110  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:30:46.827 2009  to  Wed Mar 25 20:30:46.827 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 111  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:35:03.986 2009  to  Wed Mar 25 20:35:03.986 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 112  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 20:35:03.988 2009  to  Wed Mar 25 20:35:03.988 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 113  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 20:35:04.079 2009  to  Wed Mar 25 20:35:04.079 2009   (  0.00) secs
                     drive cabinet has turned on.

 114  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Mar 25 20:35:05.106 2009  to  Wed Mar 25 20:35:05.106 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 115  FAILED    PSF        primaryMirror.command.revert                                  Wed Mar 25 22:05:53.140 2009  to  Wed Mar 25 22:09:07.673 2009   (194.53) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

 116  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:05:57.044 2009  to  Wed Mar 25 22:09:07.609 2009   (190.56) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 117  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:05:57.107 2009  to  Wed Mar 25 22:09:07.541 2009   (190.43) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 118  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 22:08:15.285 2009  to  Wed Mar 25 22:08:15.341 2009   (  0.06) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 119  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:09:23.680 2009  to  Wed Mar 25 22:10:22.844 2009   ( 59.16) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 120  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:09:23.618 2009  to  Wed Mar 25 22:10:22.911 2009   ( 59.29) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 121  FAILED    PMC        mirror.panic                                                  Wed Mar 25 22:10:22.327 2009  to  Wed Mar 25 22:10:22.327 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

 122  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Wed Mar 25 22:10:34.507 2009  to  Wed Mar 25 22:10:34.564 2009   (  0.06) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

 123  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 22:10:40.031 2009  to  Wed Mar 25 22:10:40.236 2009   (  0.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 124  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 22:10:40.094 2009  to  Wed Mar 25 22:10:40.147 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 125  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 22:12:45.138 2009  to  Wed Mar 25 22:12:45.191 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

 126  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:41:01.239 2009  to  Wed Mar 25 22:41:01.239 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 127  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:41:01.246 2009  to  Wed Mar 25 22:41:01.246 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 128  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 22:41:01.344 2009  to  Wed Mar 25 22:41:01.344 2009   (  0.00) secs
                     drive cabinet has turned on.

 129  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:46:17.153 2009  to  Wed Mar 25 22:46:17.153 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 130  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Mar 25 22:46:17.158 2009  to  Wed Mar 25 22:46:17.158 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 131  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Mar 25 22:46:17.251 2009  to  Wed Mar 25 22:46:17.251 2009   (  0.00) secs
                     drive cabinet has turned on.

 132  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 22:52:07.230 2009  to  Wed Mar 25 22:52:07.230 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 133  FAILED    PMC        VxInterface.close                                             Wed Mar 25 22:52:07.282 2009  to  Wed Mar 25 22:52:07.282 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 134  FAILED    PMC        VxInterface.close                                             Wed Mar 25 22:52:34.978 2009  to  Wed Mar 25 22:52:34.978 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 135  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 22:52:34.926 2009  to  Wed Mar 25 22:52:34.926 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 136  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 23:22:39.790 2009  to  Wed Mar 25 23:22:58.379 2009   ( 18.59) secs
                     right PSF SetInstrumentOffsets failed

 137  FAILED    IIF        command.moveFocus                                             Wed Mar 25 23:22:39.726 2009  to  Wed Mar 25 23:22:58.599 2009   ( 18.87) secs
                     IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

 138  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 23:22:39.842 2009  to  Wed Mar 25 23:22:58.323 2009   ( 18.48) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 139  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 23:22:39.978 2009  to  Wed Mar 25 23:22:58.065 2009   ( 18.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 140  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 23:22:39.894 2009  to  Wed Mar 25 23:22:58.267 2009   ( 18.37) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 141  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:22:53.960 2009  to  Wed Mar 25 23:22:53.960 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 142  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:22:53.908 2009  to  Wed Mar 25 23:22:53.908 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 143  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:32:22.824 2009  to  Wed Mar 25 23:32:22.824 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:32:22.771 2009  to  Wed Mar 25 23:32:22.771 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

 145  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:36:17.987 2009  to  Wed Mar 25 23:36:17.987 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:36:17.936 2009  to  Wed Mar 25 23:36:17.936 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 147  FAILED    PMC        VxInterface.close                                             Wed Mar 25 23:53:48.629 2009  to  Wed Mar 25 23:53:48.629 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 23:53:48.577 2009  to  Wed Mar 25 23:53:48.577 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 149  FAILED    PMC        VxInterface.close                                             Thu Mar 26 00:04:58.227 2009  to  Thu Mar 26 00:04:58.227 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

 150  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 00:04:58.175 2009  to  Thu Mar 26 00:04:58.175 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

 151  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:03:58.647 2009  to  Thu Mar 26 01:03:58.647 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 152  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:03:58.699 2009  to  Thu Mar 26 01:03:58.699 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 153  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:12:33.223 2009  to  Thu Mar 26 01:12:33.223 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:12:33.170 2009  to  Thu Mar 26 01:12:33.170 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 155  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:13:07.718 2009  to  Thu Mar 26 01:13:07.718 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 156  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:13:07.666 2009  to  Thu Mar 26 01:13:07.666 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 157  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:20:48.213 2009  to  Thu Mar 26 01:20:58.738 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

 158  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:20:53.147 2009  to  Thu Mar 26 01:21:02.080 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 159  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:20:53.082 2009  to  Thu Mar 26 01:21:02.012 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 160  FAILED    IIF        command.sendWavefront                                         Thu Mar 26 01:20:58.369 2009  to  Thu Mar 26 01:21:02.610 2009   (  4.24) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

 161  FAILED    PSF        command.applyZernikes                                         Thu Mar 26 01:20:58.576 2009  to  Thu Mar 26 01:21:02.413 2009   (  3.84) secs
                     right PSF ApplyZernikes failed

 162  FAILED    PSF        command.setZernikes                                           Thu Mar 26 01:20:58.524 2009  to  Thu Mar 26 01:21:02.490 2009   (  3.97) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 163  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:20:58.738 2009  to  Thu Mar 26 01:21:02.351 2009   (  3.61) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 164  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:21:02.012 2009  to  Thu Mar 26 01:21:02.295 2009   (  0.28) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 165  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:21:02.080 2009  to  Thu Mar 26 01:21:02.133 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 166  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 01:21:03.217 2009  to  Thu Mar 26 01:21:03.217 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 167  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:21:03.338 2009  to  Thu Mar 26 01:21:03.338 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 168  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 01:21:03.277 2009  to  Thu Mar 26 01:21:03.277 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 169  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:23:31.785 2009  to  Thu Mar 26 01:23:37.848 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

 170  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Mar 26 01:23:51.295 2009  to  Thu Mar 26 01:23:51.295 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

 171  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:28:42.261 2009  to  Thu Mar 26 01:28:42.261 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 172  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:28:42.313 2009  to  Thu Mar 26 01:28:42.313 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 173  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:39:03.767 2009  to  Thu Mar 26 01:39:03.767 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 174  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:39:03.819 2009  to  Thu Mar 26 01:39:03.819 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 175  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:57:32.199 2009  to  Thu Mar 26 01:57:32.199 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 176  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:57:32.251 2009  to  Thu Mar 26 01:57:32.251 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 177  FAILED    PMC        VxInterface.close                                             Thu Mar 26 01:58:03.216 2009  to  Thu Mar 26 01:58:03.216 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 178  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 01:58:03.164 2009  to  Thu Mar 26 01:58:03.164 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 179  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:00:20.326 2009  to  Thu Mar 26 02:00:20.326 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 180  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:00:20.273 2009  to  Thu Mar 26 02:00:20.273 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 181  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:09:18.692 2009  to  Thu Mar 26 02:09:18.692 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 182  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:09:18.744 2009  to  Thu Mar 26 02:09:18.744 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 183  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:31:51.462 2009  to  Thu Mar 26 02:31:51.462 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 184  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:31:51.513 2009  to  Thu Mar 26 02:31:51.513 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 185  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 26 02:34:08.281 2009  to  Thu Mar 26 02:34:08.281 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 186  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 26 02:34:08.333 2009  to  Thu Mar 26 02:34:08.333 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 187  FAILED    PMC        thermal.badReceive                                            Thu Mar 26 02:34:08.386 2009  to  Thu Mar 26 02:34:08.386 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 188  FAILED    PMC        VxInterface.close                                             Thu Mar 26 02:38:59.550 2009  to  Thu Mar 26 02:38:59.550 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 189  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 02:38:59.498 2009  to  Thu Mar 26 02:38:59.498 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 190  FAILED    PMC        VxInterface.close                                             Thu Mar 26 03:00:15.681 2009  to  Thu Mar 26 03:00:15.681 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 191  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 03:00:15.628 2009  to  Thu Mar 26 03:00:15.628 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 192  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 03:05:46.578 2009  to  Thu Mar 26 03:05:46.578 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 193  FAILED    PMC        VxInterface.close                                             Thu Mar 26 03:05:46.630 2009  to  Thu Mar 26 03:05:46.630 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 194  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 26 03:17:48.926 2009  to  Thu Mar 26 03:17:48.926 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 195  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:18:03.842 2009  to  Thu Mar 26 03:18:03.842 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 196  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:18:54.912 2009  to  Thu Mar 26 03:18:54.912 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 197  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Thu Mar 26 03:39:25.179 2009  to  Thu Mar 26 03:39:25.179 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 198  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Thu Mar 26 03:39:25.179 2009  to  Thu Mar 26 03:39:25.179 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

 199  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:40:21.803 2009  to  Thu Mar 26 03:40:21.803 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 200  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:41:16.911 2009  to  Thu Mar 26 03:41:16.911 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 201  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:45:25.442 2009  to  Thu Mar 26 03:45:25.442 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 202  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 26 03:54:42.706 2009  to  Thu Mar 26 03:54:42.706 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 203  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:55:50.247 2009  to  Thu Mar 26 03:55:50.247 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 204  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:55:50.899 2009  to  Thu Mar 26 03:55:50.899 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 205  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Thu Mar 26 03:55:50.899 2009  to  Thu Mar 26 03:55:50.899 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 206  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:56:10.081 2009  to  Thu Mar 26 03:56:10.081 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 207  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 03:57:46.366 2009  to  Thu Mar 26 03:57:46.366 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 208  FAILED    MCS.MCSPU  MCSPU.ELDrive.velocityNotZero                                 Thu Mar 26 04:01:04.703 2009  to  Thu Mar 26 04:01:04.703 2009   (  0.00) secs
                     Can''t proceed to next state because telescope is not motionless. It is moving at

 209  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:14:41.854 2009  to  Thu Mar 26 04:14:41.854 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

 210  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:14:41.906 2009  to  Thu Mar 26 04:14:41.906 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 211  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:17:55.777 2009  to  Thu Mar 26 04:17:55.777 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 212  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:17:55.724 2009  to  Thu Mar 26 04:17:55.724 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 213  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:24:37.615 2009  to  Thu Mar 26 04:24:37.615 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 214  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:24:37.563 2009  to  Thu Mar 26 04:24:37.563 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 215  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 04:26:39.935 2009  to  Thu Mar 26 04:26:39.935 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 216  FAILED    PMC        VxInterface.close                                             Thu Mar 26 04:26:39.987 2009  to  Thu Mar 26 04:26:39.987 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 217  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.186 2009  to  Thu Mar 26 04:52:11.186 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 218  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.442 2009  to  Thu Mar 26 04:52:11.442 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 219  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:11.723 2009  to  Thu Mar 26 04:52:11.723 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 220  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.181 2009  to  Thu Mar 26 04:52:12.181 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 221  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.436 2009  to  Thu Mar 26 04:52:12.436 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 222  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:12.691 2009  to  Thu Mar 26 04:52:12.691 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 223  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:16.802 2009  to  Thu Mar 26 04:52:16.802 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 224  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:18.073 2009  to  Thu Mar 26 04:52:18.073 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 225  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:18.331 2009  to  Thu Mar 26 04:52:18.331 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3239384e-03 -6.1067939e-04 3.1254292e-03 5.0158501e-02 5.9509277e-02 1.8980742e-02

 226  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:19.604 2009  to  Thu Mar 26 04:52:19.604 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3167858e-03 -1.2088716e-03 3.1179190e-03 8.2476616e-02 5.8826447e-02 4.0385008e-02

 227  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:19.860 2009  to  Thu Mar 26 04:52:19.860 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.3167858e-03 -1.2088716e-03 3.1179190e-03 8.2476616e-02 5.8826447e-02 4.0385008e-02

 228  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:20.116 2009  to  Thu Mar 26 04:52:20.116 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 229  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:20.365 2009  to  Thu Mar 26 04:52:20.365 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 230  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:21.026 2009  to  Thu Mar 26 04:52:21.026 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 231  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:21.282 2009  to  Thu Mar 26 04:52:21.282 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 232  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.345 2009  to  Thu Mar 26 04:52:22.345 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 233  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.599 2009  to  Thu Mar 26 04:52:22.599 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 234  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:22.853 2009  to  Thu Mar 26 04:52:22.853 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 235  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:23.511 2009  to  Thu Mar 26 04:52:23.511 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 236  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:23.765 2009  to  Thu Mar 26 04:52:23.765 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 237  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:24.826 2009  to  Thu Mar 26 04:52:24.826 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 238  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.080 2009  to  Thu Mar 26 04:52:25.080 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 239  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.334 2009  to  Thu Mar 26 04:52:25.334 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 240  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.588 2009  to  Thu Mar 26 04:52:25.588 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5022755e-03 -9.0387464e-04 3.3105612e-03 6.5997124e-02 7.6381683e-02 2.9471159e-02

 241  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 26 04:52:25.842 2009  to  Thu Mar 26 04:52:25.842 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8488169e-03 -9.1181695e-04 3.1235218e-03 4.3237686e-02 7.1046829e-02 4.0067911e-02

 242  SEQERROR  PCS        telescope.command.startTracking                               Thu Mar 26 05:30:33.170 2009  to  Thu Mar 26 05:31:12.865 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

 243  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:09.780 2009  to  Thu Mar 26 05:32:18.490 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 244  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:09.879 2009  to  Thu Mar 26 05:32:18.550 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 245  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:11.229 2009  to  Thu Mar 26 05:32:18.503 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 246  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:11.296 2009  to  Thu Mar 26 05:32:18.568 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 247  FAILED    IIF        command.moveFocus                                             Thu Mar 26 05:32:18.324 2009  to  Thu Mar 26 05:32:18.947 2009   (  0.62) secs
                     IIF MoveFocus command started for right LBC for 1.390000000000000e-01
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

 248  FAILED    IIF        command.moveFocus                                             Thu Mar 26 05:32:18.334 2009  to  Thu Mar 26 05:32:19.028 2009   (  0.69) secs
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01

 249  FAILED    PSF        command.setInstrumentOffsets                                  Thu Mar 26 05:32:18.385 2009  to  Thu Mar 26 05:32:18.780 2009   (  0.39) secs
                     left PSF SetInstrumentOffsets failed

 250  FAILED    PSF        command.setInstrumentOffsets                                  Thu Mar 26 05:32:18.398 2009  to  Thu Mar 26 05:32:18.854 2009   (  0.46) secs
                     right PSF SetInstrumentOffsets failed

 251  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:18.490 2009  to  Thu Mar 26 05:32:18.670 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 252  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:18.503 2009  to  Thu Mar 26 05:32:18.739 2009   (  0.24) secs
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 253  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Mar 26 05:32:18.438 2009  to  Thu Mar 26 05:32:18.725 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 254  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Mar 26 05:32:18.451 2009  to  Thu Mar 26 05:32:18.798 2009   (  0.35) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 255  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:18.550 2009  to  Thu Mar 26 05:32:18.603 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 256  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:18.568 2009  to  Thu Mar 26 05:32:18.620 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 257  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:55.436 2009  to  Thu Mar 26 05:32:55.436 2009   (  0.00) secs
                    Failed event but no Started event
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 258  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:55.500 2009  to  Thu Mar 26 05:32:55.500 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 259  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 26 05:32:58.026 2009  to  Thu Mar 26 05:32:58.026 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

 260  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 26 05:32:58.093 2009  to  Thu Mar 26 05:32:58.093 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 261  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 26 05:35:45.956 2009  to  Thu Mar 26 05:35:45.956 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 262  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 26 05:35:46.008 2009  to  Thu Mar 26 05:35:46.008 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 263  FAILED    PMC        thermal.badReceive                                            Thu Mar 26 05:35:46.061 2009  to  Thu Mar 26 05:35:46.061 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 264  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 26 05:44:51.535 2009  to  Thu Mar 26 05:44:51.535 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 265  FAILED    PMC        VxInterface.close                                             Thu Mar 26 05:44:51.587 2009  to  Thu Mar 26 05:44:51.587 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 266  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:50:51.903 2009  to  Thu Mar 26 05:51:30.866 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

 267  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:50:52.564 2009  to  Thu Mar 26 05:51:31.543 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 268  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:51:30.866 2009  to  Thu Mar 26 05:53:18.605 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

 269  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:51:31.543 2009  to  Thu Mar 26 05:53:19.439 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

 270  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:53:24.861 2009  to  Thu Mar 26 05:53:24.861 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

 271  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:53:24.809 2009  to  Thu Mar 26 05:53:24.809 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

 272  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 26 05:53:25.106 2009  to  Thu Mar 26 05:53:25.106 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

 273  SEQERROR  IIF        command.offset                                                Thu Mar 26 05:53:25.158 2009  to  Thu Mar 26 05:53:25.158 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

 274  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Thu Mar 26 06:10:17.779 2009  to  Thu Mar 26 06:10:17.779 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 275  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Thu Mar 26 06:10:23.942 2009  to  Thu Mar 26 06:10:23.942 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 276  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Thu Mar 26 06:10:23.942 2009  to  Thu Mar 26 06:10:23.942 2009   (  0.00) secs
                     Tried to set brakes a second time and they failed to set again.

**********************************************************
    Reporting period ending:   Thu Mar 26 06:44:58.352 2009
********************************************************************************************************