You are here: Foswiki>Software Web>TCSSWReportFile_090324 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 24 2009 to Mar 25 2009
 
    Reporting period beginning:   Tue Mar 24 18:04:00.012 2009
    Reporting period ending:      Wed Mar 25 06:46:53.023 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.51    0.16    0.00    3.50   100.0 %         81         81                      
                                                                       0.51    0.16    0.05    3.50
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.08    0.31    0.25    0.69   100.0 %         89         89                      
                                                                       0.08    0.31    0.25    0.69
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.02    0.19    0.15    0.27   100.0 %        196        196                      
                                                                       0.02    0.19    0.15    0.27
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.16    8.23    2.52   30.58    98.9 %         89         88          1           
                                                                       6.19    8.24    2.52   30.58
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    3.57   27.75   24.97   33.78   100.0 %          5          5                      
                                                                       3.57   27.75   24.97   33.78
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    2.08   13.68   12.07   17.08   100.0 %          5          5                      
                                                                       2.08   13.68   12.07   17.08
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.00    2.07    2.07    2.07   100.0 %          5          5                      
                                                                       0.00    2.07    2.07    2.07
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    4.18    5.51    0.69   30.07    94.8 %        305        289         16           
                                                                       4.16    5.67    0.69   30.07
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.68    5.33    2.54    7.65    85.7 %         28         24          4           
                                                                       1.67    5.06    2.54    7.54

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            10

IIF Events of Interest

   1  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:16:21.784 2009  to  Tue Mar 24 21:16:23.263 2009   (  1.48) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

   2  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:16:27.141 2009  to  Tue Mar 24 21:16:28.869 2009   (  1.73) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

   3  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:43:19.732 2009  to  Tue Mar 24 21:43:21.156 2009   (  1.42) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

   4  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:43:23.634 2009  to  Tue Mar 24 21:43:25.246 2009   (  1.61) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

   5  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:48:37.409 2009  to  Tue Mar 24 21:48:38.770 2009   (  1.36) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

   6  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:48:41.602 2009  to  Tue Mar 24 21:48:43.097 2009   (  1.49) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

   7  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:51:22.036 2009  to  Tue Mar 24 21:51:24.887 2009   (  2.85) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

   8  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:52:02.517 2009  to  Tue Mar 24 21:52:18.132 2009   ( 15.62) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

   9  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:58:53.577 2009  to  Tue Mar 24 21:58:54.942 2009   (  1.37) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

  10  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:58:57.406 2009  to  Tue Mar 24 21:58:59.106 2009   (  1.70) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

  11  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:00:07.898 2009  to  Tue Mar 24 22:00:09.889 2009   (  1.99) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

  12  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:00:45.830 2009  to  Tue Mar 24 22:00:47.994 2009   (  2.16) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

  13  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:03:45.790 2009  to  Tue Mar 24 22:03:47.757 2009   (  1.97) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

  14  SEQERROR  IIF        command.authorize                                             Tue Mar 24 22:04:23.268 2009  to  Tue Mar 24 22:04:32.415 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  15  SEQERROR  IIF        command.authorize                                             Tue Mar 24 22:04:26.319 2009  to  Tue Mar 24 22:04:26.319 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  16  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:28.120 2009  to  Tue Mar 24 22:04:30.185 2009   (  2.06) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

  17  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:32.940 2009  to  Tue Mar 24 22:04:34.309 2009   (  1.37) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

  18  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:37.126 2009  to  Tue Mar 24 22:04:38.697 2009   (  1.57) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

  19  FAILED    IIF        command.moveFocus                                             Wed Mar 25 03:12:47.000 2009  to  Wed Mar 25 03:12:53.675 2009   (  6.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491542555555556e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  20  FAILED    IIF        command.stepFocus                                             Wed Mar 25 03:20:59.451 2009  to  Wed Mar 25 03:21:06.155 2009   (  6.70) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  21  FAILED    IIF        command.stepFocus                                             Wed Mar 25 03:48:48.698 2009  to  Wed Mar 25 03:48:55.358 2009   (  6.66) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  22  FAILED    IIF        command.stepFocus                                             Wed Mar 25 04:13:00.614 2009  to  Wed Mar 25 04:13:08.264 2009   (  7.65) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  23  FAILED    IIF        command.stepFocus                                             Wed Mar 25 04:58:37.070 2009  to  Wed Mar 25 04:58:43.732 2009   (  6.66) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     airCompressor.command.enable . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     airCompressor.command.resetCompressorAlarm . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     chiller.command.on . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     chiller.command.resetChillerWaterFlowAlarm . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     chiller.command.resetChillerWaterPressureAlarm . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     chiller.controlValve.command.resetAlarm. . . . . . . . . . . .                                   100.0 %                                4           
                                                                                                   
     chiller.controlValve.command.setState. . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3373                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6746                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     127                      

ECS Events of Interest

   1  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 20:32:58.465 2009  to  Tue Mar 24 20:32:58.465 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

   2  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 22:36:50.289 2009  to  Tue Mar 24 22:36:50.289 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

   3  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 23:27:56.444 2009  to  Tue Mar 24 23:27:56.444 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

   4  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 23:28:21.267 2009  to  Tue Mar 24 23:28:21.267 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0412
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         10                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               4464           
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      18                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     150                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      48                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      48                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           263
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .     153                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .     153                      
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      73                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      60                      
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            61
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            37
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  8           
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             5
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      30                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .     217                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .      14                      
 *** MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 33           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      56                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                 14           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     595                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            18
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      28                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                112           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Main.termination . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.amplifierFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .     233                      
     MCSPU.Rotators.cEnergize . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.cEnable . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Rotators.rEnergize . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.RTracker.commandToVelMode. . . . . . . . . . . . . . . .       4                      
     MCSPU.Rotators.rVelMode. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rEnable . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators.rOverride . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators.rBrake. . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.Rotators.rIdle . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.setVel. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rVelCmd . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rMotionEnable . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Rotators.cMotionEnable . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Rotators.rServoReset . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .      37                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .      34                      
     MCSPU.ELDrive.Stowpins.illegalState. . . . . . . . . . . . . .                  2           
     MCSPU.RTracker.unexpectedVelMode . . . . . . . . . . . . . . .                  3           
     MCSPU.TPlcDevice.readError . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             2
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      24                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .      72                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      24                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:01.786 2009  to  Tue Mar 24 18:04:01.786 2009   (  0.00) secs
                     EL bad poly no. 5527: BAD Poly: EL = -1.070657e+00 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:04.812 2009  to  Tue Mar 24 18:04:04.812 2009   (  0.00) secs
                     EL bad poly no. 5581: BAD Poly: EL = -1.070505e+00 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:07.814 2009  to  Tue Mar 24 18:04:07.814 2009   (  0.00) secs
                     EL bad poly no. 5634: BAD Poly: EL = -1.070355e+00 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:10.870 2009  to  Tue Mar 24 18:04:10.870 2009   (  0.00) secs
                     EL bad poly no. 5688: BAD Poly: EL = -1.070201e+00 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:13.893 2009  to  Tue Mar 24 18:04:13.893 2009   (  0.00) secs
                     EL bad poly no. 5741: BAD Poly: EL = -1.070050e+00 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:16.912 2009  to  Tue Mar 24 18:04:16.912 2009   (  0.00) secs
                     EL bad poly no. 5795: BAD Poly: EL = -1.069898e+00 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:19.938 2009  to  Tue Mar 24 18:04:19.938 2009   (  0.00) secs
                     EL bad poly no. 5848: BAD Poly: EL = -1.069746e+00 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:22.985 2009  to  Tue Mar 24 18:04:22.985 2009   (  0.00) secs
                     EL bad poly no. 5902: BAD Poly: EL = -1.069594e+00 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:26.026 2009  to  Tue Mar 24 18:04:26.026 2009   (  0.00) secs
                     EL bad poly no. 5956: BAD Poly: EL = -1.069441e+00 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:29.055 2009  to  Tue Mar 24 18:04:29.055 2009   (  0.00) secs
                     EL bad poly no. 6011: BAD Poly: EL = -1.069289e+00 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:32.079 2009  to  Tue Mar 24 18:04:32.079 2009   (  0.00) secs
                     EL bad poly no. 6064: BAD Poly: EL = -1.069137e+00 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:35.111 2009  to  Tue Mar 24 18:04:35.111 2009   (  0.00) secs
                     EL bad poly no. 6118: BAD Poly: EL = -1.068985e+00 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:38.157 2009  to  Tue Mar 24 18:04:38.157 2009   (  0.00) secs
                     EL bad poly no. 6172: BAD Poly: EL = -1.068832e+00 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:41.183 2009  to  Tue Mar 24 18:04:41.183 2009   (  0.00) secs
                     EL bad poly no. 6226: BAD Poly: EL = -1.068680e+00 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:44.211 2009  to  Tue Mar 24 18:04:44.211 2009   (  0.00) secs
                     EL bad poly no. 6279: BAD Poly: EL = -1.068528e+00 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:47.217 2009  to  Tue Mar 24 18:04:47.217 2009   (  0.00) secs
                     EL bad poly no. 6332: BAD Poly: EL = -1.068378e+00 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:50.264 2009  to  Tue Mar 24 18:04:50.264 2009   (  0.00) secs
                     EL bad poly no. 6386: BAD Poly: EL = -1.068225e+00 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:53.342 2009  to  Tue Mar 24 18:04:53.342 2009   (  0.00) secs
                     EL bad poly no. 6440: BAD Poly: EL = -1.068070e+00 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:56.379 2009  to  Tue Mar 24 18:04:56.379 2009   (  0.00) secs
                     EL bad poly no. 6493: BAD Poly: EL = -1.067918e+00 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:59.409 2009  to  Tue Mar 24 18:04:59.409 2009   (  0.00) secs
                     EL bad poly no. 6547: BAD Poly: EL = -1.067765e+00 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:02.396 2009  to  Tue Mar 24 18:05:02.396 2009   (  0.00) secs
                     EL bad poly no. 6603: BAD Poly: EL = -1.067615e+00 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:05.421 2009  to  Tue Mar 24 18:05:05.421 2009   (  0.00) secs
                     EL bad poly no. 6659: BAD Poly: EL = -1.067464e+00 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:08.464 2009  to  Tue Mar 24 18:05:08.464 2009   (  0.00) secs
                     EL bad poly no. 6716: BAD Poly: EL = -1.067311e+00 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:11.499 2009  to  Tue Mar 24 18:05:11.499 2009   (  0.00) secs
                     EL bad poly no. 6772: BAD Poly: EL = -1.067158e+00 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:14.566 2009  to  Tue Mar 24 18:05:14.566 2009   (  0.00) secs
                     EL bad poly no. 6828: BAD Poly: EL = -1.067004e+00 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 18:11:01.174 2009  to  Tue Mar 24 18:11:01.174 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Tue Mar 24 18:12:25.523 2009  to  Tue Mar 24 18:12:25.523 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  28  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.903 2009  to  Tue Mar 24 18:12:25.903 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  29  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.904 2009  to  Tue Mar 24 18:12:25.904 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  30  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.904 2009  to  Tue Mar 24 18:12:25.904 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  31  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.959 2009  to  Tue Mar 24 18:12:25.959 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Tue Mar 24 18:12:27.525 2009  to  Tue Mar 24 18:12:27.525 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 18:17:51.269 2009  to  Tue Mar 24 18:17:51.269 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Tue Mar 24 18:19:57.122 2009  to  Tue Mar 24 18:19:57.122 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  35  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.502 2009  to  Tue Mar 24 18:19:57.502 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  36  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.503 2009  to  Tue Mar 24 18:19:57.503 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  37  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.504 2009  to  Tue Mar 24 18:19:57.504 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  38  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.505 2009  to  Tue Mar 24 18:19:57.505 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Tue Mar 24 18:19:59.125 2009  to  Tue Mar 24 18:19:59.125 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:43:12.731 2009  to  Tue Mar 24 18:43:12.731 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:43:12.735 2009  to  Tue Mar 24 18:43:12.735 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  42  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 18:43:12.830 2009  to  Tue Mar 24 18:43:12.830 2009   (  0.00) secs
                     drive cabinet has turned on.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.838 2009  to  Tue Mar 24 18:43:13.838 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.838 2009  to  Tue Mar 24 18:43:13.838 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.839 2009  to  Tue Mar 24 18:43:13.839 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.839 2009  to  Tue Mar 24 18:43:13.839 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  47  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.840 2009  to  Tue Mar 24 18:43:13.840 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:52:11.096 2009  to  Tue Mar 24 18:52:11.096 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:52:11.105 2009  to  Tue Mar 24 18:52:11.105 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  53  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 18:52:11.200 2009  to  Tue Mar 24 18:52:11.200 2009   (  0.00) secs
                     drive cabinet has turned on.

  54  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.207 2009  to  Tue Mar 24 18:52:12.207 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  55  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.207 2009  to  Tue Mar 24 18:52:12.207 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  56  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.208 2009  to  Tue Mar 24 18:52:12.208 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  57  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.208 2009  to  Tue Mar 24 18:52:12.208 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  58  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.209 2009  to  Tue Mar 24 18:52:12.209 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  59  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.209 2009  to  Tue Mar 24 18:52:12.209 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.210 2009  to  Tue Mar 24 18:52:12.210 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.210 2009  to  Tue Mar 24 18:52:12.210 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  62  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Tue Mar 24 18:53:01.404 2009  to  Tue Mar 24 18:53:01.404 2009   (  0.00) secs
                     Main program is terminating.

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:09:04.886 2009  to  Tue Mar 24 19:09:04.886 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:09:04.893 2009  to  Tue Mar 24 19:09:04.893 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 19:09:04.991 2009  to  Tue Mar 24 19:09:04.991 2009   (  0.00) secs
                     drive cabinet has turned on.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.014 2009  to  Tue Mar 24 19:09:06.014 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.015 2009  to  Tue Mar 24 19:09:06.015 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  74  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Tue Mar 24 19:10:07.568 2009  to  Tue Mar 24 19:10:07.568 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  75  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 19:10:20.151 2009  to  Tue Mar 24 19:10:20.151 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  76  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:21:17.067 2009  to  Tue Mar 24 19:21:17.067 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:21:17.071 2009  to  Tue Mar 24 19:21:17.071 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  78  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 19:21:17.166 2009  to  Tue Mar 24 19:21:17.166 2009   (  0.00) secs
                     drive cabinet has turned on.

  79  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:21:18.177 2009  to  Tue Mar 24 19:21:18.177 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  80  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:13:11.815 2009  to  Tue Mar 24 20:13:11.815 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  81  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:13:11.819 2009  to  Tue Mar 24 20:13:11.819 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  82  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:13:11.913 2009  to  Tue Mar 24 20:13:11.913 2009   (  0.00) secs
                     drive cabinet has turned on.

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:22:13.707 2009  to  Tue Mar 24 20:22:13.707 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:22:13.715 2009  to  Tue Mar 24 20:22:13.715 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  85  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:22:13.812 2009  to  Tue Mar 24 20:22:13.812 2009   (  0.00) secs
                     drive cabinet has turned on.

  86  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:41:58.717 2009  to  Tue Mar 24 20:41:58.717 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:41:58.724 2009  to  Tue Mar 24 20:41:58.724 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  88  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:41:58.829 2009  to  Tue Mar 24 20:41:58.829 2009   (  0.00) secs
                     drive cabinet has turned on.

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:53:21.769 2009  to  Tue Mar 24 20:53:21.769 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:53:21.777 2009  to  Tue Mar 24 20:53:21.777 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  91  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:53:21.874 2009  to  Tue Mar 24 20:53:21.874 2009   (  0.00) secs
                     drive cabinet has turned on.

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:10:54.577 2009  to  Tue Mar 24 21:10:54.577 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  93  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:10:54.585 2009  to  Tue Mar 24 21:10:54.585 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  94  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 21:10:54.682 2009  to  Tue Mar 24 21:10:54.682 2009   (  0.00) secs
                     drive cabinet has turned on.

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:45:26.393 2009  to  Tue Mar 24 21:45:26.393 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:45:26.400 2009  to  Tue Mar 24 21:45:26.400 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  97  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 21:45:26.489 2009  to  Tue Mar 24 21:45:26.489 2009   (  0.00) secs
                     drive cabinet has turned on.

  98  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.illegalState                           Tue Mar 24 21:52:40.878 2009  to  Tue Mar 24 21:52:40.878 2009   (  0.00) secs
                     Stow pin state machine''s state number =17 is illegal.

  99  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.illegalState                           Tue Mar 24 21:58:24.495 2009  to  Tue Mar 24 21:58:24.495 2009   (  0.00) secs
                     Stow pin state machine''s state number =17 is illegal.

 100  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:10:55.745 2009  to  Tue Mar 24 22:10:55.745 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:11:43.062 2009  to  Tue Mar 24 22:11:43.062 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:11:43.066 2009  to  Tue Mar 24 22:11:43.066 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 103  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:11:43.160 2009  to  Tue Mar 24 22:11:43.160 2009   (  0.00) secs
                     drive cabinet has turned on.

 104  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:23:03.363 2009  to  Tue Mar 24 22:23:03.363 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 105  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:23:03.371 2009  to  Tue Mar 24 22:23:03.371 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 106  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:23:03.469 2009  to  Tue Mar 24 22:23:03.469 2009   (  0.00) secs
                     drive cabinet has turned on.

 107  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:27:52.332 2009  to  Tue Mar 24 22:27:52.332 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 108  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:36:41.079 2009  to  Tue Mar 24 22:36:41.079 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 109  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:37:44.192 2009  to  Tue Mar 24 22:37:44.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 110  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:37:44.290 2009  to  Tue Mar 24 22:37:44.290 2009   (  0.00) secs
                     drive cabinet has turned on.

 111  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 23:01:28.154 2009  to  Tue Mar 24 23:01:28.154 2009   (  0.00) secs
                     drive cabinet has turned on.

 112  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Tue Mar 24 23:59:07.867 2009  to  Tue Mar 24 23:59:07.867 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 2 times
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.14   100.0 %        196        196                      
                                                                       0.01    0.06    0.04    0.14
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.14    0.11    0.20   100.0 %         89         89                      
                                                                       0.02    0.14    0.11    0.20
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.04    0.08    0.06    0.21   100.0 %         12         12                      
                                                                       0.04    0.08    0.06    0.21
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.22    0.51    0.30    0.86   100.0 %         12         12                      
                                                                       0.22    0.51    0.30    0.86

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    1.63    0.86    0.00    6.68    90.5 %         21         19          2           
                                                                       2.01    1.80    0.04    6.68
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    2.15    3.08    0.05    6.07    80.5 %         82         66         16           
                                                                       1.71    3.82    2.05    6.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    6.16    7.47    2.06   14.08   100.0 %          5          5                      
                                                                       6.16    7.47    2.06   14.08
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    2.74    3.05    0.05    5.06    60.0 %          5          3          2           
                                                                       0.00    5.06    5.06    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    6.81   70.11   66.17   77.98   100.0 %          3          3                      
                                                                       6.81   70.11   66.17   77.98
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.06    2.06   100.0 %          1          1                      
                                                                       0.00    2.06    2.06    2.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.83    5.92    0.05   89.22    94.6 %        429        406         23           
                                                                       7.57    5.98    2.05   89.22
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    2.09   12.55   11.07   14.03   100.0 %          2          2                      
                                                                       2.09   12.55   11.07   14.03
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .  205.07  231.64    2.18  389.90    60.0 %          5          3          2           
                                                                       9.58  381.30  370.97  389.90
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.41    0.28    0.08    1.02   100.0 %          5          5                      
                                                                       0.41    0.28    0.08    1.02
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.18    0.11    0.05    0.74   100.0 %         14         14                      
                                                                       0.18    0.11    0.05    0.74

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                         119753
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                         191840
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  2           
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  3           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      15                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      15                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       5                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           152
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                            12
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             3
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            17
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       5                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      66                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      10                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       4                      

PMC Events of Interest

   1  FAILED    PMC        actuator.forceMonitor1.panic                                  Tue Mar 24 20:17:22.829 2009  to  Tue Mar 24 20:17:22.829 2009   (  0.00) secs
                     left PMC Actuator 228 force monitor 1 PANIC! 101.4 lbs, limit is 0.0

   2  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:16:22.610 2009  to  Tue Mar 24 21:16:22.676 2009   (  0.07) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:16:22.803 2009  to  Tue Mar 24 21:16:22.855 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   4  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:16:28.037 2009  to  Tue Mar 24 21:16:28.090 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:16:28.248 2009  to  Tue Mar 24 21:16:28.301 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   6  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:43:20.507 2009  to  Tue Mar 24 21:43:20.560 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:43:20.691 2009  to  Tue Mar 24 21:43:20.746 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   8  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:43:24.502 2009  to  Tue Mar 24 21:43:24.556 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:43:24.686 2009  to  Tue Mar 24 21:43:24.739 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  10  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:48:38.136 2009  to  Tue Mar 24 21:48:38.188 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:48:38.315 2009  to  Tue Mar 24 21:48:38.368 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  12  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:48:42.443 2009  to  Tue Mar 24 21:48:42.495 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  13  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:48:42.631 2009  to  Tue Mar 24 21:48:42.685 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  14  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:51:24.239 2009  to  Tue Mar 24 21:51:24.292 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:51:24.416 2009  to  Tue Mar 24 21:51:24.470 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  16  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:52:17.418 2009  to  Tue Mar 24 21:52:17.471 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  17  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:52:17.605 2009  to  Tue Mar 24 21:52:17.659 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  18  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:58:54.294 2009  to  Tue Mar 24 21:58:54.349 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:58:54.481 2009  to  Tue Mar 24 21:58:54.534 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  20  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:58:58.213 2009  to  Tue Mar 24 21:58:58.265 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  21  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:58:58.510 2009  to  Tue Mar 24 21:58:58.563 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  22  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:00:09.252 2009  to  Tue Mar 24 22:00:09.304 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:00:09.429 2009  to  Tue Mar 24 22:00:09.481 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  24  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:00:47.330 2009  to  Tue Mar 24 22:00:47.383 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:00:47.518 2009  to  Tue Mar 24 22:00:47.569 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  26  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:03:47.117 2009  to  Tue Mar 24 22:03:47.169 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:03:47.304 2009  to  Tue Mar 24 22:03:47.356 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  28  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:29.535 2009  to  Tue Mar 24 22:04:29.589 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  29  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:29.722 2009  to  Tue Mar 24 22:04:29.775 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  30  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:33.668 2009  to  Tue Mar 24 22:04:33.721 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  31  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:33.849 2009  to  Tue Mar 24 22:04:33.903 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  32  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:37.903 2009  to  Tue Mar 24 22:04:37.955 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:38.111 2009  to  Tue Mar 24 22:04:38.164 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  34  FAILED    PMC        mirror.command.raise.auto                                     Wed Mar 25 00:33:07.964 2009  to  Wed Mar 25 00:33:20.093 2009   ( 12.13) secs
                     left PMC Mirror AutoRaise Command Failed because Raise never started

  35  FAILED    PMC        mirror.command.raise.auto                                     Wed Mar 25 00:33:17.831 2009  to  Wed Mar 25 00:33:20.015 2009   (  2.18) secs
                     right PMC Mirror AutoRaise Command Failed because Raise never started

  36  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:03.733 2009  to  Wed Mar 25 01:26:04.487 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

  37  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:04.487 2009  to  Wed Mar 25 01:26:04.751 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

  38  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:05.541 2009  to  Wed Mar 25 01:26:05.541 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

  39  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:05.805 2009  to  Wed Mar 25 01:26:05.805 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

  40  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:17.163 2009  to  Wed Mar 25 01:26:17.172 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

  41  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:18.226 2009  to  Wed Mar 25 01:26:18.226 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

  42  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:28.678 2009  to  Wed Mar 25 01:26:29.854 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

  43  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:29.854 2009  to  Wed Mar 25 01:26:30.119 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

  44  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:30.119 2009  to  Wed Mar 25 01:26:33.407 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

  45  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:33.407 2009  to  Wed Mar 25 01:26:33.617 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

  46  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.906 2009  to  Wed Mar 25 01:26:34.906 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

  47  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.906 2009  to  Wed Mar 25 01:26:34.906 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

  48  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.908 2009  to  Wed Mar 25 01:26:34.908 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

  49  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.911 2009  to  Wed Mar 25 01:26:34.911 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

  50  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:15.260 2009  to  Wed Mar 25 01:27:15.453 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

  51  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:16.506 2009  to  Wed Mar 25 01:27:16.506 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

  52  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:19.696 2009  to  Wed Mar 25 01:27:19.897 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

  53  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:20.952 2009  to  Wed Mar 25 01:27:20.952 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

  54  FAILED    PMC        command.recoverPanic                                          Wed Mar 25 01:27:39.103 2009  to  Wed Mar 25 01:27:39.156 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

  55  FAILED    PMC        command.recoverPanic                                          Wed Mar 25 01:27:42.323 2009  to  Wed Mar 25 01:27:42.375 2009   (  0.05) secs
                     left PMC RecoverPanic Command Started
                     left PMC RecoverPanic Command Failed because Wrong mirror state

  56  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:28:34.960 2009  to  Wed Mar 25 01:28:34.960 2009   (  0.00) secs
                     left PMC ** PANIC: User Button

  57  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 01:28:54.825 2009  to  Wed Mar 25 01:28:54.878 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  58  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:29:23.912 2009  to  Wed Mar 25 01:29:23.912 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

  59  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Mar 25 01:33:55.239 2009  to  Wed Mar 25 01:33:55.239 2009   (  0.00) secs
                     left PMC Actuator 437 force monitor 1 PANIC! -262.4 lbs, limit is -114.6

  60  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:45:40.291 2009  to  Wed Mar 25 01:45:40.291 2009   (  0.00) secs
                     left PMC ** PANIC: Disabled actuator set invalid

  61  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 01:47:11.336 2009  to  Wed Mar 25 01:47:11.389 2009   (  0.05) secs
                     left PMC Actuator Activate All Command Started
                     left PMC Actuator Activate All Command Failed because Wrong cell state

  62  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 02:06:42.607 2009  to  Wed Mar 25 02:07:28.753 2009   ( 46.15) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 02:06:44.493 2009  to  Wed Mar 25 02:07:19.610 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 02:16:03.993 2009  to  Wed Mar 25 02:16:03.993 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        VxInterface.close                                             Wed Mar 25 02:16:04.045 2009  to  Wed Mar 25 02:16:04.045 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 03:04:35.678 2009  to  Wed Mar 25 03:04:35.678 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.close                                             Wed Mar 25 03:04:35.731 2009  to  Wed Mar 25 03:04:35.731 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  68  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:12:47.233 2009  to  Wed Mar 25 03:12:53.296 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  69  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:20:59.684 2009  to  Wed Mar 25 03:21:05.749 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  70  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 03:42:57.035 2009  to  Wed Mar 25 03:42:57.035 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Wed Mar 25 03:42:57.087 2009  to  Wed Mar 25 03:42:57.087 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  72  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:48:48.952 2009  to  Wed Mar 25 03:48:55.015 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  73  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:09:00.265 2009  to  Wed Mar 25 04:09:00.265 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  74  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:09:00.311 2009  to  Wed Mar 25 04:09:00.311 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  75  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:12:37.021 2009  to  Wed Mar 25 04:12:37.021 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:12:36.969 2009  to  Wed Mar 25 04:12:36.969 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 04:13:00.846 2009  to  Wed Mar 25 04:13:07.911 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:13:44.611 2009  to  Wed Mar 25 04:13:44.611 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  79  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:13:44.560 2009  to  Wed Mar 25 04:13:44.560 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  80  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 04:58:37.304 2009  to  Wed Mar 25 04:58:43.366 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  81  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:01:12.586 2009  to  Wed Mar 25 05:01:12.586 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:01:12.534 2009  to  Wed Mar 25 05:01:12.534 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  83  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:04:37.209 2009  to  Wed Mar 25 05:04:37.209 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  84  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:04:37.156 2009  to  Wed Mar 25 05:04:37.156 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  85  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:04:43.503 2009  to  Wed Mar 25 05:04:43.503 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  86  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:04:43.555 2009  to  Wed Mar 25 05:04:43.555 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  87  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:21:46.800 2009  to  Wed Mar 25 05:21:46.800 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  88  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:21:46.851 2009  to  Wed Mar 25 05:21:46.851 2009   (  0.00) secs
                     right PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.19    5.26    0.45   29.81    94.8 %        305        289         16           
                                                                       4.17    5.42    0.45   29.81
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.02    0.06    0.05    0.12   100.0 %         10         10                      
                                                                       0.02    0.06    0.05    0.12
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.57    7.39    2.40   30.46    95.7 %        117        112          5           
                                                                       5.69    7.43    2.40   30.46
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.19    5.37    0.56   29.92    94.8 %        305        289         16           
                                                                       4.16    5.53    0.56   29.92
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.36    5.18    0.00   29.59    94.9 %        312        296         16           
                                                                       4.34    5.37    0.24   29.59
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.83    6.06    0.18   89.35    94.6 %        429        406         23           
                                                                       7.57    6.12    2.18   89.35
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.18    2.18    2.18   100.0 %          1          1                      
                                                                       0.00    2.18    2.18    2.18
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    6.17    7.60    2.19   14.23   100.0 %          5          5                      
                                                                       6.17    7.60    2.19   14.23
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.32    0.14    0.07    3.09   100.0 %         90         90                      
                                                                       0.32    0.14    0.07    3.09
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.01    0.14    0.14    0.14   100.0 %          2          2                      
                                                                       0.01    0.14    0.14    0.14
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    6.39   63.18   58.66   67.70   100.0 %          2          2                      
                                                                       6.39   63.18   58.66   67.70
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.57    7.28    2.29   30.35    95.7 %        117        112          5           
                                                                       5.69    7.31    2.29   30.35
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          7          7                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.04    0.12   100.0 %        312        312                      
                                                                       0.01    0.06    0.04    0.12

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:16:21.956 2009  to  Tue Mar 24 21:16:23.093 2009   (  1.14) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

   2  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:16:22.010 2009  to  Tue Mar 24 21:16:23.035 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

   3  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:16:22.172 2009  to  Tue Mar 24 21:16:22.978 2009   (  0.81) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:16:22.740 2009  to  Tue Mar 24 21:16:22.923 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   5  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:16:27.266 2009  to  Tue Mar 24 21:16:28.646 2009   (  1.38) secs
                     left PSF ApplyZernikes failed

   6  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:16:27.212 2009  to  Tue Mar 24 21:16:28.702 2009   (  1.49) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

   7  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:16:27.429 2009  to  Tue Mar 24 21:16:28.590 2009   (  1.16) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:16:28.179 2009  to  Tue Mar 24 21:16:28.509 2009   (  0.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

   9  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:43:19.903 2009  to  Tue Mar 24 21:43:20.925 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

  10  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:43:19.850 2009  to  Tue Mar 24 21:43:20.982 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  11  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:43:20.068 2009  to  Tue Mar 24 21:43:20.867 2009   (  0.80) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  12  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:43:20.627 2009  to  Tue Mar 24 21:43:20.811 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  13  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:43:23.811 2009  to  Tue Mar 24 21:43:25.022 2009   (  1.21) secs
                     left PSF ApplyZernikes failed

  14  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:43:23.759 2009  to  Tue Mar 24 21:43:25.078 2009   (  1.32) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  15  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:43:23.972 2009  to  Tue Mar 24 21:43:24.964 2009   (  0.99) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:43:24.623 2009  to  Tue Mar 24 21:43:24.909 2009   (  0.29) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  17  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:48:37.528 2009  to  Tue Mar 24 21:48:38.543 2009   (  1.01) secs
                     right PSF ApplyZernikes failed

  18  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:48:37.476 2009  to  Tue Mar 24 21:48:38.600 2009   (  1.12) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  19  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:48:37.693 2009  to  Tue Mar 24 21:48:38.487 2009   (  0.79) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  20  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:48:38.253 2009  to  Tue Mar 24 21:48:38.431 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  21  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:48:41.671 2009  to  Tue Mar 24 21:48:42.924 2009   (  1.25) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  22  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:48:41.724 2009  to  Tue Mar 24 21:48:42.866 2009   (  1.14) secs
                     left PSF ApplyZernikes failed

  23  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:48:41.888 2009  to  Tue Mar 24 21:48:42.809 2009   (  0.92) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:48:42.566 2009  to  Tue Mar 24 21:48:42.751 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  25  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:51:22.105 2009  to  Tue Mar 24 21:51:24.711 2009   (  2.61) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  26  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:51:22.157 2009  to  Tue Mar 24 21:51:24.653 2009   (  2.50) secs
                     right PSF ApplyZernikes failed

  27  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:51:22.319 2009  to  Tue Mar 24 21:51:24.596 2009   (  2.28) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  28  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:51:24.355 2009  to  Tue Mar 24 21:51:24.537 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  29  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:52:02.638 2009  to  Tue Mar 24 21:52:17.906 2009   ( 15.27) secs
                     left PSF ApplyZernikes failed

  30  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:52:02.585 2009  to  Tue Mar 24 21:52:17.961 2009   ( 15.38) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  31  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:52:02.805 2009  to  Tue Mar 24 21:52:17.805 2009   ( 15.00) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  32  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:52:17.542 2009  to  Tue Mar 24 21:52:17.749 2009   (  0.21) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  33  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:58:53.645 2009  to  Tue Mar 24 21:58:54.770 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  34  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:58:53.698 2009  to  Tue Mar 24 21:58:54.713 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

  35  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:58:53.859 2009  to  Tue Mar 24 21:58:54.656 2009   (  0.80) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:58:54.418 2009  to  Tue Mar 24 21:58:54.599 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  37  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:58:57.530 2009  to  Tue Mar 24 21:58:58.795 2009   (  1.27) secs
                     left PSF ApplyZernikes failed

  38  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:58:57.475 2009  to  Tue Mar 24 21:58:58.851 2009   (  1.38) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  39  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:58:57.693 2009  to  Tue Mar 24 21:58:58.739 2009   (  1.05) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:58:58.334 2009  to  Tue Mar 24 21:58:58.684 2009   (  0.35) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  41  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:00:08.024 2009  to  Tue Mar 24 22:00:09.662 2009   (  1.64) secs
                     right PSF ApplyZernikes failed

  42  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:00:07.971 2009  to  Tue Mar 24 22:00:09.719 2009   (  1.75) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  43  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:00:08.188 2009  to  Tue Mar 24 22:00:09.607 2009   (  1.42) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  44  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:00:09.367 2009  to  Tue Mar 24 22:00:09.551 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  45  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:00:45.965 2009  to  Tue Mar 24 22:00:47.750 2009   (  1.78) secs
                     left PSF ApplyZernikes failed

  46  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:00:45.912 2009  to  Tue Mar 24 22:00:47.822 2009   (  1.91) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  47  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:00:46.129 2009  to  Tue Mar 24 22:00:47.694 2009   (  1.56) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:00:47.454 2009  to  Tue Mar 24 22:00:47.637 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  49  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:03:45.857 2009  to  Tue Mar 24 22:03:47.585 2009   (  1.73) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  50  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:03:45.909 2009  to  Tue Mar 24 22:03:47.530 2009   (  1.62) secs
                     right PSF ApplyZernikes failed

  51  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:03:46.070 2009  to  Tue Mar 24 22:03:47.475 2009   (  1.41) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:03:47.240 2009  to  Tue Mar 24 22:03:47.420 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  53  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:28.188 2009  to  Tue Mar 24 22:04:30.016 2009   (  1.83) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  54  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:28.241 2009  to  Tue Mar 24 22:04:29.961 2009   (  1.72) secs
                     left PSF ApplyZernikes failed

  55  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:28.405 2009  to  Tue Mar 24 22:04:29.905 2009   (  1.50) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:29.660 2009  to  Tue Mar 24 22:04:29.849 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  57  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:33.007 2009  to  Tue Mar 24 22:04:34.139 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  58  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:33.060 2009  to  Tue Mar 24 22:04:34.083 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

  59  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:33.221 2009  to  Tue Mar 24 22:04:34.027 2009   (  0.81) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:33.786 2009  to  Tue Mar 24 22:04:33.972 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  61  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:37.246 2009  to  Tue Mar 24 22:04:38.469 2009   (  1.22) secs
                     left PSF ApplyZernikes failed

  62  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:37.192 2009  to  Tue Mar 24 22:04:38.526 2009   (  1.33) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  63  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:37.407 2009  to  Tue Mar 24 22:04:38.413 2009   (  1.01) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:38.028 2009  to  Tue Mar 24 22:04:38.357 2009   (  0.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  65  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 02:06:42.542 2009  to  Wed Mar 25 02:07:28.823 2009   ( 46.28) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 02:06:44.431 2009  to  Wed Mar 25 02:07:19.687 2009   ( 35.26) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Wed Mar 25 02:54:40.647 2009  to  Wed Mar 25 02:54:47.697 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  68  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Wed Mar 25 02:54:58.597 2009  to  Wed Mar 25 02:54:58.597 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  69  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:12:47.059 2009  to  Wed Mar 25 03:12:53.495 2009   (  6.44) secs
                     right PSF SetInstrumentOffsets failed

  70  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:12:47.112 2009  to  Wed Mar 25 03:12:53.439 2009   (  6.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  71  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:12:47.164 2009  to  Wed Mar 25 03:12:53.383 2009   (  6.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  72  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:20:59.509 2009  to  Wed Mar 25 03:21:05.924 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  73  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:20:59.562 2009  to  Wed Mar 25 03:21:05.868 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  74  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:20:59.615 2009  to  Wed Mar 25 03:21:05.811 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  75  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:48:48.763 2009  to  Wed Mar 25 03:48:55.188 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

  76  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:48:48.835 2009  to  Wed Mar 25 03:48:55.132 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  77  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:48:48.887 2009  to  Wed Mar 25 03:48:55.076 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 04:13:00.679 2009  to  Wed Mar 25 04:13:08.086 2009   (  7.41) secs
                     right PSF SetInstrumentOffsets failed

  79  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 04:13:00.783 2009  to  Wed Mar 25 04:13:07.975 2009   (  7.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  80  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 04:13:00.731 2009  to  Wed Mar 25 04:13:08.031 2009   (  7.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  81  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 04:58:37.133 2009  to  Wed Mar 25 04:58:43.557 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

  82  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 04:58:37.238 2009  to  Wed Mar 25 04:58:43.439 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 04:58:37.186 2009  to  Wed Mar 25 04:58:43.498 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:01.786 2009  to  Tue Mar 24 18:04:01.786 2009   (  0.00) secs
                     EL bad poly no. 5527: BAD Poly: EL = -1.070657e+00 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:04.812 2009  to  Tue Mar 24 18:04:04.812 2009   (  0.00) secs
                     EL bad poly no. 5581: BAD Poly: EL = -1.070505e+00 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:07.814 2009  to  Tue Mar 24 18:04:07.814 2009   (  0.00) secs
                     EL bad poly no. 5634: BAD Poly: EL = -1.070355e+00 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:10.870 2009  to  Tue Mar 24 18:04:10.870 2009   (  0.00) secs
                     EL bad poly no. 5688: BAD Poly: EL = -1.070201e+00 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:13.893 2009  to  Tue Mar 24 18:04:13.893 2009   (  0.00) secs
                     EL bad poly no. 5741: BAD Poly: EL = -1.070050e+00 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:16.912 2009  to  Tue Mar 24 18:04:16.912 2009   (  0.00) secs
                     EL bad poly no. 5795: BAD Poly: EL = -1.069898e+00 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:19.938 2009  to  Tue Mar 24 18:04:19.938 2009   (  0.00) secs
                     EL bad poly no. 5848: BAD Poly: EL = -1.069746e+00 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:22.985 2009  to  Tue Mar 24 18:04:22.985 2009   (  0.00) secs
                     EL bad poly no. 5902: BAD Poly: EL = -1.069594e+00 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:26.026 2009  to  Tue Mar 24 18:04:26.026 2009   (  0.00) secs
                     EL bad poly no. 5956: BAD Poly: EL = -1.069441e+00 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:29.055 2009  to  Tue Mar 24 18:04:29.055 2009   (  0.00) secs
                     EL bad poly no. 6011: BAD Poly: EL = -1.069289e+00 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:32.079 2009  to  Tue Mar 24 18:04:32.079 2009   (  0.00) secs
                     EL bad poly no. 6064: BAD Poly: EL = -1.069137e+00 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:35.111 2009  to  Tue Mar 24 18:04:35.111 2009   (  0.00) secs
                     EL bad poly no. 6118: BAD Poly: EL = -1.068985e+00 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:38.157 2009  to  Tue Mar 24 18:04:38.157 2009   (  0.00) secs
                     EL bad poly no. 6172: BAD Poly: EL = -1.068832e+00 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:41.183 2009  to  Tue Mar 24 18:04:41.183 2009   (  0.00) secs
                     EL bad poly no. 6226: BAD Poly: EL = -1.068680e+00 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:44.211 2009  to  Tue Mar 24 18:04:44.211 2009   (  0.00) secs
                     EL bad poly no. 6279: BAD Poly: EL = -1.068528e+00 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:47.217 2009  to  Tue Mar 24 18:04:47.217 2009   (  0.00) secs
                     EL bad poly no. 6332: BAD Poly: EL = -1.068378e+00 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:50.264 2009  to  Tue Mar 24 18:04:50.264 2009   (  0.00) secs
                     EL bad poly no. 6386: BAD Poly: EL = -1.068225e+00 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:53.342 2009  to  Tue Mar 24 18:04:53.342 2009   (  0.00) secs
                     EL bad poly no. 6440: BAD Poly: EL = -1.068070e+00 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:56.379 2009  to  Tue Mar 24 18:04:56.379 2009   (  0.00) secs
                     EL bad poly no. 6493: BAD Poly: EL = -1.067918e+00 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:04:59.409 2009  to  Tue Mar 24 18:04:59.409 2009   (  0.00) secs
                     EL bad poly no. 6547: BAD Poly: EL = -1.067765e+00 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:02.396 2009  to  Tue Mar 24 18:05:02.396 2009   (  0.00) secs
                     EL bad poly no. 6603: BAD Poly: EL = -1.067615e+00 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:05.421 2009  to  Tue Mar 24 18:05:05.421 2009   (  0.00) secs
                     EL bad poly no. 6659: BAD Poly: EL = -1.067464e+00 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:08.464 2009  to  Tue Mar 24 18:05:08.464 2009   (  0.00) secs
                     EL bad poly no. 6716: BAD Poly: EL = -1.067311e+00 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:11.499 2009  to  Tue Mar 24 18:05:11.499 2009   (  0.00) secs
                     EL bad poly no. 6772: BAD Poly: EL = -1.067158e+00 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 18:05:14.566 2009  to  Tue Mar 24 18:05:14.566 2009   (  0.00) secs
                     EL bad poly no. 6828: BAD Poly: EL = -1.067004e+00 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 18:11:01.174 2009  to  Tue Mar 24 18:11:01.174 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Tue Mar 24 18:12:25.523 2009  to  Tue Mar 24 18:12:25.523 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  28  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.903 2009  to  Tue Mar 24 18:12:25.903 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  29  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.904 2009  to  Tue Mar 24 18:12:25.904 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  30  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.904 2009  to  Tue Mar 24 18:12:25.904 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  31  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:12:25.959 2009  to  Tue Mar 24 18:12:25.959 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Tue Mar 24 18:12:27.525 2009  to  Tue Mar 24 18:12:27.525 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 18:17:51.269 2009  to  Tue Mar 24 18:17:51.269 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Tue Mar 24 18:19:57.122 2009  to  Tue Mar 24 18:19:57.122 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  35  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.502 2009  to  Tue Mar 24 18:19:57.502 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  36  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.503 2009  to  Tue Mar 24 18:19:57.503 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  37  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.504 2009  to  Tue Mar 24 18:19:57.504 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  38  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Tue Mar 24 18:19:57.505 2009  to  Tue Mar 24 18:19:57.505 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Tue Mar 24 18:19:59.125 2009  to  Tue Mar 24 18:19:59.125 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:43:12.731 2009  to  Tue Mar 24 18:43:12.731 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:43:12.735 2009  to  Tue Mar 24 18:43:12.735 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  42  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 18:43:12.830 2009  to  Tue Mar 24 18:43:12.830 2009   (  0.00) secs
                     drive cabinet has turned on.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.838 2009  to  Tue Mar 24 18:43:13.838 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.838 2009  to  Tue Mar 24 18:43:13.838 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.839 2009  to  Tue Mar 24 18:43:13.839 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.839 2009  to  Tue Mar 24 18:43:13.839 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  47  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.840 2009  to  Tue Mar 24 18:43:13.840 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:43:13.841 2009  to  Tue Mar 24 18:43:13.841 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:52:11.096 2009  to  Tue Mar 24 18:52:11.096 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 18:52:11.105 2009  to  Tue Mar 24 18:52:11.105 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  53  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 18:52:11.200 2009  to  Tue Mar 24 18:52:11.200 2009   (  0.00) secs
                     drive cabinet has turned on.

  54  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.207 2009  to  Tue Mar 24 18:52:12.207 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  55  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.207 2009  to  Tue Mar 24 18:52:12.207 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  56  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.208 2009  to  Tue Mar 24 18:52:12.208 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  57  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.208 2009  to  Tue Mar 24 18:52:12.208 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  58  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.209 2009  to  Tue Mar 24 18:52:12.209 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  59  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.209 2009  to  Tue Mar 24 18:52:12.209 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.210 2009  to  Tue Mar 24 18:52:12.210 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 18:52:12.210 2009  to  Tue Mar 24 18:52:12.210 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  62  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Tue Mar 24 18:53:01.404 2009  to  Tue Mar 24 18:53:01.404 2009   (  0.00) secs
                     Main program is terminating.

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:09:04.886 2009  to  Tue Mar 24 19:09:04.886 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:09:04.893 2009  to  Tue Mar 24 19:09:04.893 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  65  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 19:09:04.991 2009  to  Tue Mar 24 19:09:04.991 2009   (  0.00) secs
                     drive cabinet has turned on.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.013 2009  to  Tue Mar 24 19:09:06.013 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.014 2009  to  Tue Mar 24 19:09:06.014 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.015 2009  to  Tue Mar 24 19:09:06.015 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:09:06.016 2009  to  Tue Mar 24 19:09:06.016 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  74  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Tue Mar 24 19:10:07.568 2009  to  Tue Mar 24 19:10:07.568 2009   (  0.00) secs
                     EL:FR pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  75  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Tue Mar 24 19:10:20.151 2009  to  Tue Mar 24 19:10:20.151 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  76  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:21:17.067 2009  to  Tue Mar 24 19:21:17.067 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 19:21:17.071 2009  to  Tue Mar 24 19:21:17.071 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  78  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 19:21:17.166 2009  to  Tue Mar 24 19:21:17.166 2009   (  0.00) secs
                     drive cabinet has turned on.

  79  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Tue Mar 24 19:21:18.177 2009  to  Tue Mar 24 19:21:18.177 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  80  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:13:11.815 2009  to  Tue Mar 24 20:13:11.815 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  81  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:13:11.819 2009  to  Tue Mar 24 20:13:11.819 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  82  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:13:11.913 2009  to  Tue Mar 24 20:13:11.913 2009   (  0.00) secs
                     drive cabinet has turned on.

  83  FAILED    PMC        actuator.forceMonitor1.panic                                  Tue Mar 24 20:17:22.829 2009  to  Tue Mar 24 20:17:22.829 2009   (  0.00) secs
                     left PMC Actuator 228 force monitor 1 PANIC! 101.4 lbs, limit is 0.0

  84  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:22:13.707 2009  to  Tue Mar 24 20:22:13.707 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  85  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:22:13.715 2009  to  Tue Mar 24 20:22:13.715 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  86  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:22:13.812 2009  to  Tue Mar 24 20:22:13.812 2009   (  0.00) secs
                     drive cabinet has turned on.

  87  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 20:32:58.465 2009  to  Tue Mar 24 20:32:58.465 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:41:58.717 2009  to  Tue Mar 24 20:41:58.717 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:41:58.724 2009  to  Tue Mar 24 20:41:58.724 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  90  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:41:58.829 2009  to  Tue Mar 24 20:41:58.829 2009   (  0.00) secs
                     drive cabinet has turned on.

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:53:21.769 2009  to  Tue Mar 24 20:53:21.769 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 20:53:21.777 2009  to  Tue Mar 24 20:53:21.777 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  93  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 20:53:21.874 2009  to  Tue Mar 24 20:53:21.874 2009   (  0.00) secs
                     drive cabinet has turned on.

  94  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:10:54.577 2009  to  Tue Mar 24 21:10:54.577 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  95  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:10:54.585 2009  to  Tue Mar 24 21:10:54.585 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  96  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 21:10:54.682 2009  to  Tue Mar 24 21:10:54.682 2009   (  0.00) secs
                     drive cabinet has turned on.

  97  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:16:21.784 2009  to  Tue Mar 24 21:16:23.263 2009   (  1.48) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

  98  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:16:21.956 2009  to  Tue Mar 24 21:16:23.093 2009   (  1.14) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  99  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:16:22.010 2009  to  Tue Mar 24 21:16:23.035 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

 100  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:16:22.172 2009  to  Tue Mar 24 21:16:22.978 2009   (  0.81) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 101  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:16:22.610 2009  to  Tue Mar 24 21:16:22.676 2009   (  0.07) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 102  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:16:22.740 2009  to  Tue Mar 24 21:16:22.923 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 103  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:16:22.803 2009  to  Tue Mar 24 21:16:22.855 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 104  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:16:27.141 2009  to  Tue Mar 24 21:16:28.869 2009   (  1.73) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 105  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:16:27.266 2009  to  Tue Mar 24 21:16:28.646 2009   (  1.38) secs
                     left PSF ApplyZernikes failed

 106  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:16:27.212 2009  to  Tue Mar 24 21:16:28.702 2009   (  1.49) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 107  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:16:27.429 2009  to  Tue Mar 24 21:16:28.590 2009   (  1.16) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 108  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:16:28.037 2009  to  Tue Mar 24 21:16:28.090 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 109  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:16:28.179 2009  to  Tue Mar 24 21:16:28.509 2009   (  0.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 110  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:16:28.248 2009  to  Tue Mar 24 21:16:28.301 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 111  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:43:19.732 2009  to  Tue Mar 24 21:43:21.156 2009   (  1.42) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 112  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:43:19.903 2009  to  Tue Mar 24 21:43:20.925 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

 113  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:43:19.850 2009  to  Tue Mar 24 21:43:20.982 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 114  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:43:20.068 2009  to  Tue Mar 24 21:43:20.867 2009   (  0.80) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 115  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:43:20.507 2009  to  Tue Mar 24 21:43:20.560 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 116  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:43:20.691 2009  to  Tue Mar 24 21:43:20.746 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 117  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:43:20.627 2009  to  Tue Mar 24 21:43:20.811 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 118  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:43:23.634 2009  to  Tue Mar 24 21:43:25.246 2009   (  1.61) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 119  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:43:23.811 2009  to  Tue Mar 24 21:43:25.022 2009   (  1.21) secs
                     left PSF ApplyZernikes failed

 120  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:43:23.759 2009  to  Tue Mar 24 21:43:25.078 2009   (  1.32) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 121  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:43:23.972 2009  to  Tue Mar 24 21:43:24.964 2009   (  0.99) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 122  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:43:24.502 2009  to  Tue Mar 24 21:43:24.556 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 123  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:43:24.623 2009  to  Tue Mar 24 21:43:24.909 2009   (  0.29) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 124  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:43:24.686 2009  to  Tue Mar 24 21:43:24.739 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 125  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:45:26.393 2009  to  Tue Mar 24 21:45:26.393 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 126  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 21:45:26.400 2009  to  Tue Mar 24 21:45:26.400 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 127  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 21:45:26.489 2009  to  Tue Mar 24 21:45:26.489 2009   (  0.00) secs
                     drive cabinet has turned on.

 128  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:48:37.409 2009  to  Tue Mar 24 21:48:38.770 2009   (  1.36) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 129  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:48:37.528 2009  to  Tue Mar 24 21:48:38.543 2009   (  1.01) secs
                     right PSF ApplyZernikes failed

 130  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:48:37.476 2009  to  Tue Mar 24 21:48:38.600 2009   (  1.12) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 131  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:48:37.693 2009  to  Tue Mar 24 21:48:38.487 2009   (  0.79) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 132  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:48:38.136 2009  to  Tue Mar 24 21:48:38.188 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 133  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:48:38.315 2009  to  Tue Mar 24 21:48:38.368 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 134  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:48:38.253 2009  to  Tue Mar 24 21:48:38.431 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 135  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:48:41.671 2009  to  Tue Mar 24 21:48:42.924 2009   (  1.25) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 136  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:48:41.602 2009  to  Tue Mar 24 21:48:43.097 2009   (  1.49) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 137  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:48:41.724 2009  to  Tue Mar 24 21:48:42.866 2009   (  1.14) secs
                     left PSF ApplyZernikes failed

 138  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:48:41.888 2009  to  Tue Mar 24 21:48:42.809 2009   (  0.92) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 139  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:48:42.443 2009  to  Tue Mar 24 21:48:42.495 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 140  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:48:42.631 2009  to  Tue Mar 24 21:48:42.685 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 141  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:48:42.566 2009  to  Tue Mar 24 21:48:42.751 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 142  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:51:22.036 2009  to  Tue Mar 24 21:51:24.887 2009   (  2.85) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 143  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:51:22.105 2009  to  Tue Mar 24 21:51:24.711 2009   (  2.61) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 144  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:51:22.157 2009  to  Tue Mar 24 21:51:24.653 2009   (  2.50) secs
                     right PSF ApplyZernikes failed

 145  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:51:22.319 2009  to  Tue Mar 24 21:51:24.596 2009   (  2.28) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 146  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:51:24.239 2009  to  Tue Mar 24 21:51:24.292 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 147  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:51:24.355 2009  to  Tue Mar 24 21:51:24.537 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 148  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:51:24.416 2009  to  Tue Mar 24 21:51:24.470 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 149  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:52:02.517 2009  to  Tue Mar 24 21:52:18.132 2009   ( 15.62) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 150  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:52:02.638 2009  to  Tue Mar 24 21:52:17.906 2009   ( 15.27) secs
                     left PSF ApplyZernikes failed

 151  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:52:02.585 2009  to  Tue Mar 24 21:52:17.961 2009   ( 15.38) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 152  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:52:02.805 2009  to  Tue Mar 24 21:52:17.805 2009   ( 15.00) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 153  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:52:17.418 2009  to  Tue Mar 24 21:52:17.471 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 154  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:52:17.542 2009  to  Tue Mar 24 21:52:17.749 2009   (  0.21) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 155  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:52:17.605 2009  to  Tue Mar 24 21:52:17.659 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 156  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.illegalState                           Tue Mar 24 21:52:40.878 2009  to  Tue Mar 24 21:52:40.878 2009   (  0.00) secs
                     Stow pin state machine''s state number =17 is illegal.

 157  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.illegalState                           Tue Mar 24 21:58:24.495 2009  to  Tue Mar 24 21:58:24.495 2009   (  0.00) secs
                     Stow pin state machine''s state number =17 is illegal.

 158  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:58:53.645 2009  to  Tue Mar 24 21:58:54.770 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 159  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:58:53.577 2009  to  Tue Mar 24 21:58:54.942 2009   (  1.37) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 160  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:58:53.698 2009  to  Tue Mar 24 21:58:54.713 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

 161  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:58:53.859 2009  to  Tue Mar 24 21:58:54.656 2009   (  0.80) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 162  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:58:54.294 2009  to  Tue Mar 24 21:58:54.349 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 163  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:58:54.418 2009  to  Tue Mar 24 21:58:54.599 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 164  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:58:54.481 2009  to  Tue Mar 24 21:58:54.534 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 165  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 21:58:57.406 2009  to  Tue Mar 24 21:58:59.106 2009   (  1.70) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 166  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 21:58:57.530 2009  to  Tue Mar 24 21:58:58.795 2009   (  1.27) secs
                     left PSF ApplyZernikes failed

 167  FAILED    PSF        command.setZernikes                                           Tue Mar 24 21:58:57.475 2009  to  Tue Mar 24 21:58:58.851 2009   (  1.38) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 168  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 21:58:57.693 2009  to  Tue Mar 24 21:58:58.739 2009   (  1.05) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 169  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 21:58:58.213 2009  to  Tue Mar 24 21:58:58.265 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 170  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 21:58:58.334 2009  to  Tue Mar 24 21:58:58.684 2009   (  0.35) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 171  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 21:58:58.510 2009  to  Tue Mar 24 21:58:58.563 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 172  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:00:07.898 2009  to  Tue Mar 24 22:00:09.889 2009   (  1.99) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 173  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:00:08.024 2009  to  Tue Mar 24 22:00:09.662 2009   (  1.64) secs
                     right PSF ApplyZernikes failed

 174  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:00:07.971 2009  to  Tue Mar 24 22:00:09.719 2009   (  1.75) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 175  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:00:08.188 2009  to  Tue Mar 24 22:00:09.607 2009   (  1.42) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 176  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:00:09.252 2009  to  Tue Mar 24 22:00:09.304 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 177  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:00:09.429 2009  to  Tue Mar 24 22:00:09.481 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 178  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:00:09.367 2009  to  Tue Mar 24 22:00:09.551 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 179  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:00:45.830 2009  to  Tue Mar 24 22:00:47.994 2009   (  2.16) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 180  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:00:45.965 2009  to  Tue Mar 24 22:00:47.750 2009   (  1.78) secs
                     left PSF ApplyZernikes failed

 181  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:00:45.912 2009  to  Tue Mar 24 22:00:47.822 2009   (  1.91) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 182  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:00:46.129 2009  to  Tue Mar 24 22:00:47.694 2009   (  1.56) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 183  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:00:47.330 2009  to  Tue Mar 24 22:00:47.383 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 184  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:00:47.518 2009  to  Tue Mar 24 22:00:47.569 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 185  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:00:47.454 2009  to  Tue Mar 24 22:00:47.637 2009   (  0.18) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 186  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:03:45.857 2009  to  Tue Mar 24 22:03:47.585 2009   (  1.73) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 187  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:03:45.790 2009  to  Tue Mar 24 22:03:47.757 2009   (  1.97) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 188  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:03:45.909 2009  to  Tue Mar 24 22:03:47.530 2009   (  1.62) secs
                     right PSF ApplyZernikes failed

 189  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:03:46.070 2009  to  Tue Mar 24 22:03:47.475 2009   (  1.41) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 190  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:03:47.117 2009  to  Tue Mar 24 22:03:47.169 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 191  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:03:47.240 2009  to  Tue Mar 24 22:03:47.420 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 192  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:03:47.304 2009  to  Tue Mar 24 22:03:47.356 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 193  SEQERROR  IIF        command.authorize                                             Tue Mar 24 22:04:23.268 2009  to  Tue Mar 24 22:04:32.415 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 194  SEQERROR  IIF        command.authorize                                             Tue Mar 24 22:04:26.319 2009  to  Tue Mar 24 22:04:26.319 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 195  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:28.188 2009  to  Tue Mar 24 22:04:30.016 2009   (  1.83) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 196  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:28.120 2009  to  Tue Mar 24 22:04:30.185 2009   (  2.06) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 197  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:28.241 2009  to  Tue Mar 24 22:04:29.961 2009   (  1.72) secs
                     left PSF ApplyZernikes failed

 198  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:28.405 2009  to  Tue Mar 24 22:04:29.905 2009   (  1.50) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 199  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:29.535 2009  to  Tue Mar 24 22:04:29.589 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 200  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:29.660 2009  to  Tue Mar 24 22:04:29.849 2009   (  0.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 201  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:29.722 2009  to  Tue Mar 24 22:04:29.775 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 202  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:32.940 2009  to  Tue Mar 24 22:04:34.309 2009   (  1.37) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for right LBC for M1

 203  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:33.007 2009  to  Tue Mar 24 22:04:34.139 2009   (  1.13) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 204  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:33.060 2009  to  Tue Mar 24 22:04:34.083 2009   (  1.02) secs
                     right PSF ApplyZernikes failed

 205  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:33.221 2009  to  Tue Mar 24 22:04:34.027 2009   (  0.81) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 206  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:33.668 2009  to  Tue Mar 24 22:04:33.721 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 207  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:33.786 2009  to  Tue Mar 24 22:04:33.972 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 208  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:33.849 2009  to  Tue Mar 24 22:04:33.903 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 209  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 22:04:37.126 2009  to  Tue Mar 24 22:04:38.697 2009   (  1.57) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF SendWavefront command failed for left LBC for M1

 210  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 22:04:37.246 2009  to  Tue Mar 24 22:04:38.469 2009   (  1.22) secs
                     left PSF ApplyZernikes failed

 211  FAILED    PSF        command.setZernikes                                           Tue Mar 24 22:04:37.192 2009  to  Tue Mar 24 22:04:38.526 2009   (  1.33) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

 212  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 22:04:37.407 2009  to  Tue Mar 24 22:04:38.413 2009   (  1.01) secs
                     left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 213  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 22:04:37.903 2009  to  Tue Mar 24 22:04:37.955 2009   (  0.05) secs
                     left PMC Actuator ChangeAllOffsets Command Started
                     left PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 214  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 22:04:38.028 2009  to  Tue Mar 24 22:04:38.357 2009   (  0.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 215  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 22:04:38.111 2009  to  Tue Mar 24 22:04:38.164 2009   (  0.05) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 216  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:10:55.745 2009  to  Tue Mar 24 22:10:55.745 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 217  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:11:43.062 2009  to  Tue Mar 24 22:11:43.062 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 218  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:11:43.066 2009  to  Tue Mar 24 22:11:43.066 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 219  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:11:43.160 2009  to  Tue Mar 24 22:11:43.160 2009   (  0.00) secs
                     drive cabinet has turned on.

 220  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:23:03.363 2009  to  Tue Mar 24 22:23:03.363 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 221  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:23:03.371 2009  to  Tue Mar 24 22:23:03.371 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 222  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:23:03.469 2009  to  Tue Mar 24 22:23:03.469 2009   (  0.00) secs
                     drive cabinet has turned on.

 223  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:27:52.332 2009  to  Tue Mar 24 22:27:52.332 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 224  FAILED    MCS.MCSPU  MCSPU.RTracker.unexpectedVelMode                              Tue Mar 24 22:36:41.079 2009  to  Tue Mar 24 22:36:41.079 2009   (  0.00) secs
                     LDG axis servo has unexpectedly changed to velocity mode!

 225  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 22:36:50.289 2009  to  Tue Mar 24 22:36:50.289 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

 226  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 22:37:44.192 2009  to  Tue Mar 24 22:37:44.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 227  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 22:37:44.290 2009  to  Tue Mar 24 22:37:44.290 2009   (  0.00) secs
                     drive cabinet has turned on.

 228  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Tue Mar 24 23:01:28.154 2009  to  Tue Mar 24 23:01:28.154 2009   (  0.00) secs
                     drive cabinet has turned on.

 229  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 23:27:56.444 2009  to  Tue Mar 24 23:27:56.444 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0410

 230  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Mar 24 23:28:21.267 2009  to  Tue Mar 24 23:28:21.267 2009   (  0.00) secs
                     Chiller control valve command reset alarm failed:index CV0412

 231  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Tue Mar 24 23:59:07.867 2009  to  Tue Mar 24 23:59:07.867 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 2 times

 232  FAILED    PMC        mirror.command.raise.auto                                     Wed Mar 25 00:33:07.964 2009  to  Wed Mar 25 00:33:20.093 2009   ( 12.13) secs
                     left PMC Mirror AutoRaise Command Failed because Raise never started

 233  FAILED    PMC        mirror.command.raise.auto                                     Wed Mar 25 00:33:17.831 2009  to  Wed Mar 25 00:33:20.015 2009   (  2.18) secs
                     right PMC Mirror AutoRaise Command Failed because Raise never started

 234  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:03.733 2009  to  Wed Mar 25 01:26:04.487 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

 235  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:04.487 2009  to  Wed Mar 25 01:26:04.751 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

 236  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:05.541 2009  to  Wed Mar 25 01:26:05.541 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

 237  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:05.805 2009  to  Wed Mar 25 01:26:05.805 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

 238  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:17.163 2009  to  Wed Mar 25 01:26:17.172 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

 239  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:18.226 2009  to  Wed Mar 25 01:26:18.226 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

 240  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:28.678 2009  to  Wed Mar 25 01:26:29.854 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

 241  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:29.854 2009  to  Wed Mar 25 01:26:30.119 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

 242  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:30.119 2009  to  Wed Mar 25 01:26:33.407 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

 243  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:33.407 2009  to  Wed Mar 25 01:26:33.617 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

 244  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.906 2009  to  Wed Mar 25 01:26:34.906 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

 245  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.906 2009  to  Wed Mar 25 01:26:34.906 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

 246  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.908 2009  to  Wed Mar 25 01:26:34.908 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

 247  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:26:34.911 2009  to  Wed Mar 25 01:26:34.911 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

 248  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:15.260 2009  to  Wed Mar 25 01:27:15.453 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Actuator Activate All Command Started

 249  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:16.506 2009  to  Wed Mar 25 01:27:16.506 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Actuator Activate All Command Complete

 250  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:19.696 2009  to  Wed Mar 25 01:27:19.897 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Actuator Activate All Command Started

 251  SEQERROR  PMC        actuator.command.activate.all                                 Wed Mar 25 01:27:20.952 2009  to  Wed Mar 25 01:27:20.952 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Actuator Activate All Command Complete

 252  FAILED    PMC        command.recoverPanic                                          Wed Mar 25 01:27:39.103 2009  to  Wed Mar 25 01:27:39.156 2009   (  0.05) secs
                     right PMC RecoverPanic Command Started
                     right PMC RecoverPanic Command Failed because Wrong mirror state

 253  FAILED    PMC        command.recoverPanic                                          Wed Mar 25 01:27:42.323 2009  to  Wed Mar 25 01:27:42.375 2009   (  0.05) secs
                     left PMC RecoverPanic Command Started
                     left PMC RecoverPanic Command Failed because Wrong mirror state

 254  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:28:34.960 2009  to  Wed Mar 25 01:28:34.960 2009   (  0.00) secs
                     left PMC ** PANIC: User Button

 255  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 01:28:54.825 2009  to  Wed Mar 25 01:28:54.878 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Failed because Wrong cell state

 256  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:29:23.912 2009  to  Wed Mar 25 01:29:23.912 2009   (  0.00) secs
                     right PMC ** PANIC: User Button

 257  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Mar 25 01:33:55.239 2009  to  Wed Mar 25 01:33:55.239 2009   (  0.00) secs
                     left PMC Actuator 437 force monitor 1 PANIC! -262.4 lbs, limit is -114.6

 258  FAILED    PMC        mirror.panic                                                  Wed Mar 25 01:45:40.291 2009  to  Wed Mar 25 01:45:40.291 2009   (  0.00) secs
                     left PMC ** PANIC: Disabled actuator set invalid

 259  FAILED    PMC        actuator.command.activate.all                                 Wed Mar 25 01:47:11.336 2009  to  Wed Mar 25 01:47:11.389 2009   (  0.05) secs
                     left PMC Actuator Activate All Command Started
                     left PMC Actuator Activate All Command Failed because Wrong cell state

 260  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 02:06:42.542 2009  to  Wed Mar 25 02:07:28.823 2009   ( 46.28) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 261  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 02:06:42.607 2009  to  Wed Mar 25 02:07:28.753 2009   ( 46.15) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 262  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 02:06:44.431 2009  to  Wed Mar 25 02:07:19.687 2009   ( 35.26) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 263  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 02:06:44.493 2009  to  Wed Mar 25 02:07:19.610 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 264  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 02:16:03.993 2009  to  Wed Mar 25 02:16:03.993 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 265  FAILED    PMC        VxInterface.close                                             Wed Mar 25 02:16:04.045 2009  to  Wed Mar 25 02:16:04.045 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 266  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Wed Mar 25 02:54:40.647 2009  to  Wed Mar 25 02:54:47.697 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 267  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Wed Mar 25 02:54:58.597 2009  to  Wed Mar 25 02:54:58.597 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

 268  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 03:04:35.678 2009  to  Wed Mar 25 03:04:35.678 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 269  FAILED    PMC        VxInterface.close                                             Wed Mar 25 03:04:35.731 2009  to  Wed Mar 25 03:04:35.731 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 270  FAILED    IIF        command.moveFocus                                             Wed Mar 25 03:12:47.000 2009  to  Wed Mar 25 03:12:53.675 2009   (  6.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491542555555556e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 271  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:12:47.059 2009  to  Wed Mar 25 03:12:53.495 2009   (  6.44) secs
                     right PSF SetInstrumentOffsets failed

 272  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:12:47.112 2009  to  Wed Mar 25 03:12:53.439 2009   (  6.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 273  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:12:47.164 2009  to  Wed Mar 25 03:12:53.383 2009   (  6.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 274  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:12:47.233 2009  to  Wed Mar 25 03:12:53.296 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 275  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:20:59.509 2009  to  Wed Mar 25 03:21:05.924 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 276  FAILED    IIF        command.stepFocus                                             Wed Mar 25 03:20:59.451 2009  to  Wed Mar 25 03:21:06.155 2009   (  6.70) secs
                     IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 277  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:20:59.562 2009  to  Wed Mar 25 03:21:05.868 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 278  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:20:59.684 2009  to  Wed Mar 25 03:21:05.749 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 279  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:20:59.615 2009  to  Wed Mar 25 03:21:05.811 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 280  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 03:42:57.035 2009  to  Wed Mar 25 03:42:57.035 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 281  FAILED    PMC        VxInterface.close                                             Wed Mar 25 03:42:57.087 2009  to  Wed Mar 25 03:42:57.087 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 282  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 03:48:48.763 2009  to  Wed Mar 25 03:48:55.188 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

 283  FAILED    IIF        command.stepFocus                                             Wed Mar 25 03:48:48.698 2009  to  Wed Mar 25 03:48:55.358 2009   (  6.66) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 284  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 03:48:48.835 2009  to  Wed Mar 25 03:48:55.132 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 285  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 03:48:48.887 2009  to  Wed Mar 25 03:48:55.076 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 286  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 03:48:48.952 2009  to  Wed Mar 25 03:48:55.015 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 287  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:09:00.265 2009  to  Wed Mar 25 04:09:00.265 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 288  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:09:00.311 2009  to  Wed Mar 25 04:09:00.311 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 289  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:12:37.021 2009  to  Wed Mar 25 04:12:37.021 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 290  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:12:36.969 2009  to  Wed Mar 25 04:12:36.969 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 291  FAILED    IIF        command.stepFocus                                             Wed Mar 25 04:13:00.614 2009  to  Wed Mar 25 04:13:08.264 2009   (  7.65) secs
                     IIF StepFocus command started for right LBC for 0.000000000000000e+00
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 292  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 04:13:00.679 2009  to  Wed Mar 25 04:13:08.086 2009   (  7.41) secs
                     right PSF SetInstrumentOffsets failed

 293  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 04:13:00.783 2009  to  Wed Mar 25 04:13:07.975 2009   (  7.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 294  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 04:13:00.731 2009  to  Wed Mar 25 04:13:08.031 2009   (  7.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 295  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 04:13:00.846 2009  to  Wed Mar 25 04:13:07.911 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 296  FAILED    PMC        VxInterface.close                                             Wed Mar 25 04:13:44.611 2009  to  Wed Mar 25 04:13:44.611 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 297  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 04:13:44.560 2009  to  Wed Mar 25 04:13:44.560 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 298  FAILED    IIF        command.stepFocus                                             Wed Mar 25 04:58:37.070 2009  to  Wed Mar 25 04:58:43.732 2009   (  6.66) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 299  FAILED    PSF        command.setInstrumentOffsets                                  Wed Mar 25 04:58:37.133 2009  to  Wed Mar 25 04:58:43.557 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

 300  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Mar 25 04:58:37.238 2009  to  Wed Mar 25 04:58:43.439 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 301  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Mar 25 04:58:37.186 2009  to  Wed Mar 25 04:58:43.498 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 302  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Mar 25 04:58:37.304 2009  to  Wed Mar 25 04:58:43.366 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 303  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:01:12.586 2009  to  Wed Mar 25 05:01:12.586 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 304  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:01:12.534 2009  to  Wed Mar 25 05:01:12.534 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 305  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:04:37.209 2009  to  Wed Mar 25 05:04:37.209 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 306  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:04:37.156 2009  to  Wed Mar 25 05:04:37.156 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

 307  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:04:43.503 2009  to  Wed Mar 25 05:04:43.503 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 308  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:04:43.555 2009  to  Wed Mar 25 05:04:43.555 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 309  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 25 05:21:46.800 2009  to  Wed Mar 25 05:21:46.800 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 310  FAILED    PMC        VxInterface.close                                             Wed Mar 25 05:21:46.851 2009  to  Wed Mar 25 05:21:46.851 2009   (  0.00) secs
                     right PMC Actuator closing network connection

**********************************************************
    Reporting period ending:   Wed Mar 25 06:46:53.023 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback