    TCS Software Performance Report
 
    Observing Night:   Mar 23 2009 to Mar 24 2009
 
    Reporting period beginning:   Mon Mar 23 18:03:03.516 2009
    Reporting period ending:      Tue Mar 24 06:47:58.297 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.10   100.0 %        157        157                      
                                                                       0.01    0.05    0.05    0.10
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.23    0.33    0.23    3.38   100.0 %        215        215                      
                                                                       0.23    0.33    0.23    3.38
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.02    0.19    0.15    0.31   100.0 %        200        200                      
                                                                       0.02    0.19    0.15    0.31
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.68    7.38    0.63   35.80    97.2 %        214        208          6           
                                                                       5.37    7.32    2.51   20.56
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    3.15    8.11    0.00   16.76   100.0 %         20         20                      
                                                                       2.58    8.53    4.75   16.76
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    2.72    7.37    0.00   13.48   100.0 %         20         20                      
                                                                       2.15    7.76    4.06   13.48
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    7.04   12.81    1.70   26.86    88.9 %         18         12          2          4
                                                                       6.80   13.82    7.81   26.86
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    9.05    6.42    1.26   33.11   100.0 %         17         17                      
                                                                       9.05    6.42    1.26   33.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.25    2.01    1.05    2.08   100.0 %         16         16                      
                                                                       0.25    2.01    1.05    2.08
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    8.21    8.96    0.00   55.02    98.7 %        379        374          5           
                                                                       7.89    8.89    0.68   52.98
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.00    4.06    3.53    5.56   100.0 %          4          4                      
                                                                       1.00    4.06    3.53    5.56

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            16

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Mon Mar 23 18:56:39.101 2009  to  Mon Mar 23 18:56:39.734 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

   2  FAILED    IIF        command.moveFocus                                             Mon Mar 23 18:58:44.250 2009  to  Mon Mar 23 18:58:44.882 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

   3  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:02:57.297 2009  to  Mon Mar 23 19:03:03.937 2009   (  6.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491408539351852e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

   4  SEQERROR  IIF        command.offset                                                Mon Mar 23 19:03:31.456 2009  to  Mon Mar 23 19:04:12.023 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

   5  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 23 19:03:32.141 2009  to  Mon Mar 23 19:04:12.622 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

   6  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 23 19:04:18.478 2009  to  Mon Mar 23 19:04:18.478 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

   7  SEQERROR  IIF        command.offset                                                Mon Mar 23 19:04:18.530 2009  to  Mon Mar 23 19:04:18.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

   8  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:37:04.411 2009  to  Mon Mar 23 19:37:11.097 2009   (  6.69) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491410908564815e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   9  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:41:13.953 2009  to  Mon Mar 23 19:41:20.592 2009   (  6.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491411197916666e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  10  FAILED    IIF        command.sendWavefront                                         Mon Mar 23 19:46:40.904 2009  to  Mon Mar 23 19:46:44.785 2009   (  3.88) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

  11  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 23 20:41:56.901 2009  to  Mon Mar 23 20:42:08.769 2009   ( 11.87) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  12  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 01:24:43.730 2009  to  Tue Mar 24 01:25:38.748 2009   ( 55.02) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  13  FAILED    IIF        command.moveFocus                                             Tue Mar 24 01:26:01.092 2009  to  Tue Mar 24 01:26:36.890 2009   ( 35.80) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491435141203704e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  14  SEQERROR  IIF        command.sendWavefront                                         Tue Mar 24 01:27:33.915 2009  to  Tue Mar 24 01:28:07.810 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  15  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 01:28:07.810 2009  to  Tue Mar 24 01:28:09.935 2009   (  2.12) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  16  SEQERROR  IIF        command.sendWavefront                                         Tue Mar 24 01:28:11.109 2009  to  Tue Mar 24 01:28:11.109 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF SendWavefront command failed for right LBC for M1

  17  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 03:07:38.182 2009  to  Tue Mar 24 03:07:51.097 2009   ( 12.92) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  18  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 24 03:31:49.982 2009  to  Tue Mar 24 03:31:51.686 2009   (  1.70) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491443878472222e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - BAD Poly:last poly t0 = 4744607545.004 which is > current poly t0 = 4744607544.
                     IIF Preset command failed for both LBC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.on . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     chiller.controlValve.command.setState. . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3796                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7592                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     180                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       4                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      56                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     114                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     276                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      92                      
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                 72           
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                             6
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:50.417 2009  to  Tue Mar 24 03:31:50.417 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly: EL = -9.358467e-03 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 03:31:51.421 2009  to  Tue Mar 24 03:31:51.421 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:53.452 2009  to  Tue Mar 24 03:31:53.452 2009   (  0.00) secs
                     EL bad poly no. 41: BAD Poly: EL = -1.895775e-02 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:56.503 2009  to  Tue Mar 24 03:31:56.503 2009   (  0.00) secs
                     EL bad poly no. 102: BAD Poly: EL = -1.576364e-02 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:59.526 2009  to  Tue Mar 24 03:31:59.526 2009   (  0.00) secs
                     EL bad poly no. 152: BAD Poly: EL = -1.514399e-02 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:02.545 2009  to  Tue Mar 24 03:32:02.545 2009   (  0.00) secs
                     EL bad poly no. 183: BAD Poly: EL = -1.528635e-02 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:05.635 2009  to  Tue Mar 24 03:32:05.635 2009   (  0.00) secs
                     EL bad poly no. 214: BAD Poly: EL = -1.531917e-02 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:08.716 2009  to  Tue Mar 24 03:32:08.716 2009   (  0.00) secs
                     EL bad poly no. 245: BAD Poly: EL = -1.531142e-02 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:11.761 2009  to  Tue Mar 24 03:32:11.761 2009   (  0.00) secs
                     EL bad poly no. 278: BAD Poly: EL = -1.530964e-02 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:14.771 2009  to  Tue Mar 24 03:32:14.771 2009   (  0.00) secs
                     EL bad poly no. 325: BAD Poly: EL = -1.531007e-02 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:17.775 2009  to  Tue Mar 24 03:32:17.775 2009   (  0.00) secs
                     EL bad poly no. 385: BAD Poly: EL = -1.531019e-02 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:20.825 2009  to  Tue Mar 24 03:32:20.825 2009   (  0.00) secs
                     EL bad poly no. 446: BAD Poly: EL = -1.531020e-02 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:23.826 2009  to  Tue Mar 24 03:32:23.826 2009   (  0.00) secs
                     EL bad poly no. 506: BAD Poly: EL = -1.531025e-02 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:26.874 2009  to  Tue Mar 24 03:32:26.874 2009   (  0.00) secs
                     EL bad poly no. 567: BAD Poly: EL = -1.531034e-02 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:29.874 2009  to  Tue Mar 24 03:32:29.874 2009   (  0.00) secs
                     EL bad poly no. 627: BAD Poly: EL = -1.531041e-02 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:32.874 2009  to  Tue Mar 24 03:32:32.874 2009   (  0.00) secs
                     EL bad poly no. 687: BAD Poly: EL = -1.531053e-02 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:35.876 2009  to  Tue Mar 24 03:32:35.876 2009   (  0.00) secs
                     EL bad poly no. 747: BAD Poly: EL = -1.531063e-02 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:38.926 2009  to  Tue Mar 24 03:32:38.926 2009   (  0.00) secs
                     EL bad poly no. 808: BAD Poly: EL = -1.531078e-02 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:41.927 2009  to  Tue Mar 24 03:32:41.927 2009   (  0.00) secs
                     EL bad poly no. 868: BAD Poly: EL = -1.531090e-02 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:44.978 2009  to  Tue Mar 24 03:32:44.978 2009   (  0.00) secs
                     EL bad poly no. 929: BAD Poly: EL = -1.531119e-02 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:48.029 2009  to  Tue Mar 24 03:32:48.029 2009   (  0.00) secs
                     EL bad poly no. 990: BAD Poly: EL = -1.531132e-02 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:51.077 2009  to  Tue Mar 24 03:32:51.077 2009   (  0.00) secs
                     EL bad poly no. 1051: BAD Poly: EL = -1.531154e-02 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:54.126 2009  to  Tue Mar 24 03:32:54.126 2009   (  0.00) secs
                     EL bad poly no. 1112: BAD Poly: EL = -1.531172e-02 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:57.137 2009  to  Tue Mar 24 03:32:57.137 2009   (  0.00) secs
                     EL bad poly no. 1170: BAD Poly: EL = -1.531198e-02 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:33:00.181 2009  to  Tue Mar 24 03:33:00.181 2009   (  0.00) secs
                     EL bad poly no. 1224: BAD Poly: EL = -1.531225e-02 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:33:03.184 2009  to  Tue Mar 24 03:33:03.184 2009   (  0.00) secs
                     EL bad poly no. 1278: BAD Poly: EL = -1.531248e-02 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.06    0.04    0.11   100.0 %        200        200                      
                                                                       0.01    0.06    0.04    0.11
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.13    0.10    0.22   100.0 %        215        215                      
                                                                       0.03    0.13    0.10    0.22
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.62    0.43    0.12    3.06   100.0 %         20         20                      
                                                                       0.62    0.43    0.12    3.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.09    0.10    0.05    0.51   100.0 %         28         28                      
                                                                       0.09    0.10    0.05    0.51
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.19    0.55    0.31    0.84    96.4 %         28         27          1           
                                                                       0.19    0.56    0.31    0.84

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  FAILED    PCS        telescope.command.startTracking                               Tue Mar 24 03:31:50.713 2009  to  Tue Mar 24 03:31:51.112 2009   (  0.40) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - BAD Poly:last poly t0 = 4744607545.004 which is > current poly t0 = 4744607544.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.58    0.55    0.05    1.06    50.0 %          4          2          2           
                                                                       0.00    1.06    1.06    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.73    3.38    0.05    8.07    99.4 %        157        156          1           
                                                                       1.72    3.40    2.05    8.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.02    2.07    2.06    2.09   100.0 %          4          4                      
                                                                       0.02    2.07    2.06    2.09
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.06    5.05    5.06   100.0 %          2          2                      
                                                                       0.00    5.06    5.05    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.17   66.17   66.17   100.0 %          2          2                      
                                                                       0.00   66.17   66.17   66.17
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.06    2.05    2.06   100.0 %          4          4                      
                                                                       0.00    2.06    2.05    2.06
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .   11.16    7.77    0.00  198.42    97.4 %        644        627         17           
                                                                       7.89    7.37    0.13  105.25
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .   13.48  295.28  285.75  304.81   100.0 %          2          2                      
                                                                      13.48  295.28  285.75  304.81
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.02    0.11    0.10    0.12   100.0 %          2          2                      
                                                                       0.02    0.11    0.10    0.12
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06   100.0 %          7          7                      
                                                                       0.01    0.06    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       4                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           524
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     156                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            34
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 22           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 22           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      22                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           408
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           399
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             8
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      10                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      10                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             5
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor2.panic . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:55:43.456 2009  to  Mon Mar 23 18:56:39.332 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:56:39.332 2009  to  Mon Mar 23 18:56:39.386 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   3  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:56:41.623 2009  to  Mon Mar 23 18:56:41.623 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   4  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:41.178 2009  to  Mon Mar 23 18:58:44.480 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:44.480 2009  to  Mon Mar 23 18:58:44.533 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:54.254 2009  to  Mon Mar 23 18:58:54.254 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:02:57.533 2009  to  Mon Mar 23 19:03:03.596 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:03:31.740 2009  to  Mon Mar 23 19:03:34.666 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:03:36.722 2009  to  Mon Mar 23 19:03:36.722 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  10  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:38.535 2009  to  Mon Mar 23 19:22:52.389 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:52.389 2009  to  Mon Mar 23 19:22:52.441 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  12  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:53.613 2009  to  Mon Mar 23 19:22:53.613 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  13  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 19:31:02.530 2009  to  Mon Mar 23 19:31:02.530 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Mon Mar 23 19:31:02.581 2009  to  Mon Mar 23 19:31:02.581 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:37:04.649 2009  to  Mon Mar 23 19:37:10.716 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:41:14.185 2009  to  Mon Mar 23 19:41:20.250 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:28.920 2009  to  Mon Mar 23 19:46:44.386 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:44.386 2009  to  Mon Mar 23 19:46:44.439 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  19  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:45.002 2009  to  Mon Mar 23 19:46:45.002 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  20  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 20:32:01.961 2009  to  Mon Mar 23 20:32:01.961 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  21  FAILED    PMC        VxInterface.close                                             Mon Mar 23 20:32:02.013 2009  to  Mon Mar 23 20:32:02.013 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  22  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 20:41:59.511 2009  to  Mon Mar 23 20:42:08.580 2009   (  9.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 23 20:56:13.179 2009  to  Mon Mar 23 20:56:13.179 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  24  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 23 20:56:13.232 2009  to  Mon Mar 23 20:56:13.232 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  25  FAILED    PMC        thermal.badReceive                                            Mon Mar 23 20:56:13.284 2009  to  Mon Mar 23 20:56:13.284 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  26  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 20:57:46.730 2009  to  Mon Mar 23 20:57:46.730 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  27  FAILED    PMC        VxInterface.close                                             Mon Mar 23 20:57:46.776 2009  to  Mon Mar 23 20:57:46.776 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:06:09.155 2009  to  Mon Mar 23 21:06:09.155 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:06:09.207 2009  to  Mon Mar 23 21:06:09.207 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:22:14.763 2009  to  Mon Mar 23 21:22:14.763 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:22:14.711 2009  to  Mon Mar 23 21:22:14.711 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:22:17.268 2009  to  Mon Mar 23 21:22:17.268 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:22:17.216 2009  to  Mon Mar 23 21:22:17.216 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:39:35.612 2009  to  Mon Mar 23 21:39:35.612 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:39:35.559 2009  to  Mon Mar 23 21:39:35.559 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:43:39.519 2009  to  Mon Mar 23 21:43:39.519 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:43:39.571 2009  to  Mon Mar 23 21:43:39.571 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:58:42.384 2009  to  Mon Mar 23 21:58:42.384 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:58:42.437 2009  to  Mon Mar 23 21:58:42.437 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:08:31.796 2009  to  Mon Mar 23 22:08:31.796 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:08:31.848 2009  to  Mon Mar 23 22:08:31.848 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  42  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:24:08.156 2009  to  Mon Mar 23 22:24:08.156 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  43  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:24:08.209 2009  to  Mon Mar 23 22:24:08.209 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  44  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:38:58.923 2009  to  Mon Mar 23 22:38:58.923 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:38:58.974 2009  to  Mon Mar 23 22:38:58.974 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:01:10.637 2009  to  Tue Mar 24 00:01:10.637 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:01:10.586 2009  to  Tue Mar 24 00:01:10.586 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:35:24.556 2009  to  Tue Mar 24 00:35:24.556 2009   (  0.00) secs
                     right PMC AirPressure length error: expected 100, got 96

  49  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:35:24.608 2009  to  Tue Mar 24 00:35:24.608 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:35:54.251 2009  to  Tue Mar 24 00:35:54.251 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:35:54.303 2009  to  Tue Mar 24 00:35:54.303 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:38:42.904 2009  to  Tue Mar 24 00:38:42.904 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:38:42.851 2009  to  Tue Mar 24 00:38:42.851 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:24:47.240 2009  to  Tue Mar 24 01:25:38.392 2009   ( 51.15) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:26:01.426 2009  to  Tue Mar 24 01:26:36.543 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:26:58.383 2009  to  Tue Mar 24 01:27:33.502 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:27:37.384 2009  to  Tue Mar 24 01:28:09.496 2009   ( 32.11) secs
                     right PMC ** PANIC: Hardpoint breakaway
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PMC        mirror.panic                                                  Tue Mar 24 01:28:09.475 2009  to  Tue Mar 24 01:28:09.475 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 01:28:10.417 2009  to  Tue Mar 24 01:28:10.470 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  60  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:28:10.597 2009  to  Tue Mar 24 01:28:10.650 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:31:34.065 2009  to  Tue Mar 24 01:31:34.120 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  62  FAILED    PMC        actuator.command.activate.all                                 Tue Mar 24 01:34:20.360 2009  to  Tue Mar 24 01:34:20.414 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:40:05.434 2009  to  Tue Mar 24 01:43:23.856 2009   (198.42) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PMC        mirror.panic                                                  Tue Mar 24 01:44:06.652 2009  to  Tue Mar 24 01:44:06.652 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

  65  FAILED    PMC        actuator.command.activate.all                                 Tue Mar 24 01:57:13.853 2009  to  Tue Mar 24 01:57:13.907 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

  66  FAILED    PMC        actuator.forceMonitor2.panic                                  Tue Mar 24 01:59:30.016 2009  to  Tue Mar 24 01:59:30.016 2009   (  0.00) secs
                     right PMC Actuator 210 force monitor 2 PANIC! 165.8 lbs, limit is 64.1

  67  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:09:16.093 2009  to  Tue Mar 24 02:09:16.093 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  68  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:09:16.041 2009  to  Tue Mar 24 02:09:16.041 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  69  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:19:01.018 2009  to  Tue Mar 24 02:19:01.018 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  70  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:19:01.071 2009  to  Tue Mar 24 02:19:01.071 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  71  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:19:01.518 2009  to  Tue Mar 24 02:19:01.518 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  72  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:19:01.571 2009  to  Tue Mar 24 02:19:01.571 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  73  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:28:40.783 2009  to  Tue Mar 24 02:28:40.783 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:28:40.731 2009  to  Tue Mar 24 02:28:40.731 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  75  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:48:19.590 2009  to  Tue Mar 24 02:48:19.590 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  76  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:48:19.641 2009  to  Tue Mar 24 02:48:19.641 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  77  FAILED    PMC        VxInterface.close                                             Tue Mar 24 03:18:41.868 2009  to  Tue Mar 24 03:18:41.868 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 03:18:41.817 2009  to  Tue Mar 24 03:18:41.817 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  79  FAILED    PMC        VxInterface.packetReadError                                   Tue Mar 24 03:19:33.454 2009  to  Tue Mar 24 03:19:33.454 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  80  FAILED    PMC        VxInterface.selectTimeout                                     Tue Mar 24 03:19:33.402 2009  to  Tue Mar 24 03:19:33.402 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  81  FAILED    PMC        thermal.badReceive                                            Tue Mar 24 03:19:33.506 2009  to  Tue Mar 24 03:19:33.506 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    8.32    8.80    0.45   54.72    98.7 %        379        374          5           
                                                                       7.89    8.63    0.45   52.68
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         36         36                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.64    7.17    0.40   35.49    97.2 %        218        212          6           
                                                                       5.33    7.11    2.39   20.43
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    8.21    8.82    0.00   54.83    98.7 %        379        374          5           
                                                                       7.89    8.74    0.56   52.79
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    8.38    8.81    0.00   54.50    98.7 %        397        392          5           
                                                                       7.97    8.67    0.24   52.46
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   11.17    7.90    0.00  198.55    97.4 %        644        627         17           
                                                                       7.89    7.51    0.26  105.39
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.03    2.20    2.18    2.25   100.0 %          4          4                      
                                                                       0.03    2.20    2.18    2.25
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.02    2.21    2.18    2.23   100.0 %          4          4                      
                                                                       0.02    2.21    2.18    2.23
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.09    0.07    0.61   100.0 %        246        246                      
                                                                       0.04    0.09    0.07    0.61
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.07    0.13    0.09    0.18   100.0 %          2          2                      
                                                                       0.07    0.13    0.09    0.18
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   40.75   61.33   31.59  107.78   100.0 %          3          3                      
                                                                      40.75   61.33   31.59  107.78
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    9.04   12.72    0.29   25.37    80.0 %          5          4          1           
                                                                       6.68   15.83   10.32   25.37
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.64    7.05    0.29   35.38    97.2 %        218        212          6           
                                                                       5.34    6.99    2.29   20.32
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.06    0.06    0.10   100.0 %         18         18                      
                                                                       0.01    0.06    0.06    0.10
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.06    0.05    0.12   100.0 %        397        397                      
                                                                       0.01    0.06    0.05    0.12

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .              18112           

PSF Events of Interest

   1  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:55:43.393 2009  to  Mon Mar 23 18:56:39.268 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   2  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 18:56:39.163 2009  to  Mon Mar 23 18:56:39.561 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

   3  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 18:56:39.215 2009  to  Mon Mar 23 18:56:39.505 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:56:39.268 2009  to  Mon Mar 23 18:56:39.449 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:56:41.684 2009  to  Mon Mar 23 18:56:41.684 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   6  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:41.111 2009  to  Mon Mar 23 18:58:44.417 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   7  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 18:58:44.312 2009  to  Mon Mar 23 18:58:44.713 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

   8  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 18:58:44.365 2009  to  Mon Mar 23 18:58:44.657 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   9  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:44.417 2009  to  Mon Mar 23 18:58:44.601 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:54.322 2009  to  Mon Mar 23 18:58:54.322 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  11  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:02:57.364 2009  to  Mon Mar 23 19:03:03.769 2009   (  6.40) secs
                     right PSF SetInstrumentOffsets failed

  12  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:02:57.470 2009  to  Mon Mar 23 19:03:03.659 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:02:57.417 2009  to  Mon Mar 23 19:03:03.714 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  14  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:03:31.677 2009  to  Mon Mar 23 19:03:34.603 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  15  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:03:36.787 2009  to  Mon Mar 23 19:03:36.787 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  16  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:38.468 2009  to  Mon Mar 23 19:22:52.325 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:52.325 2009  to  Mon Mar 23 19:22:52.503 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  18  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:53.675 2009  to  Mon Mar 23 19:22:53.675 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  19  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:37:04.483 2009  to  Mon Mar 23 19:37:10.893 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  20  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:37:04.535 2009  to  Mon Mar 23 19:37:10.838 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:37:04.587 2009  to  Mon Mar 23 19:37:10.783 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:41:14.017 2009  to  Mon Mar 23 19:41:20.426 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  23  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:41:14.070 2009  to  Mon Mar 23 19:41:20.369 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:41:14.123 2009  to  Mon Mar 23 19:41:20.314 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:28.612 2009  to  Mon Mar 23 19:46:41.186 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

  26  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:28.856 2009  to  Mon Mar 23 19:46:44.325 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  27  FAILED    PSF        command.setZernikes                                           Mon Mar 23 19:46:40.973 2009  to  Mon Mar 23 19:46:44.670 2009   (  3.70) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  28  FAILED    PSF        command.applyZernikes                                         Mon Mar 23 19:46:41.025 2009  to  Mon Mar 23 19:46:44.614 2009   (  3.59) secs
                     right PSF ApplyZernikes failed

  29  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:41.186 2009  to  Mon Mar 23 19:46:44.558 2009   (  3.37) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:44.325 2009  to  Mon Mar 23 19:46:44.503 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  31  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:45.071 2009  to  Mon Mar 23 19:46:45.071 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  32  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:45.128 2009  to  Mon Mar 23 19:46:45.128 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:52.346 2009  to  Mon Mar 23 20:11:52.346 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.6138973e-04 -1.0121465e-03 3.0442476e-03 4.4746399e-03 3.0403137e-02 2.8483629e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.008 2009  to  Mon Mar 23 20:11:53.008 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.264 2009  to  Mon Mar 23 20:11:53.264 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.520 2009  to  Mon Mar 23 20:11:53.520 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.777 2009  to  Mon Mar 23 20:11:53.777 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:03.954 2009  to  Mon Mar 23 20:12:03.954 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  39  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:07.238 2009  to  Mon Mar 23 20:12:07.238 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  40  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:07.492 2009  to  Mon Mar 23 20:12:07.492 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  41  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:11.179 2009  to  Mon Mar 23 20:12:11.179 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.8145313e-04 -1.0187030e-03 3.0598640e-03 -4.0422440e-02 6.1340332e-03 8.1212521e-03

  42  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:11.434 2009  to  Mon Mar 23 20:12:11.434 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.8145313e-04 -1.0187030e-03 3.0598640e-03 -4.0422440e-02 6.1340332e-03 8.1212521e-03

  43  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:13.102 2009  to  Mon Mar 23 20:12:13.102 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6166439e-04 -7.2455406e-04 3.0434132e-03 -1.1168480e-02 5.7342529e-02 7.8518391e-03

  44  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:13.357 2009  to  Mon Mar 23 20:12:13.357 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6166439e-04 -7.2455406e-04 3.0434132e-03 -1.1168480e-02 5.7342529e-02 7.8518391e-03

  45  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:17.462 2009  to  Mon Mar 23 20:12:17.462 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  46  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:17.717 2009  to  Mon Mar 23 20:12:17.717 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  47  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:19.393 2009  to  Mon Mar 23 20:12:19.393 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  48  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:19.648 2009  to  Mon Mar 23 20:12:19.648 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  49  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:20.917 2009  to  Mon Mar 23 20:12:20.917 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  50  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:21.172 2009  to  Mon Mar 23 20:12:21.172 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  51  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:24.268 2009  to  Mon Mar 23 20:12:24.268 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  52  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:24.524 2009  to  Mon Mar 23 20:12:24.524 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  53  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:33.504 2009  to  Mon Mar 23 20:12:33.504 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  54  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:33.758 2009  to  Mon Mar 23 20:12:33.758 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:37.466 2009  to  Mon Mar 23 20:12:37.466 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  56  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:37.721 2009  to  Mon Mar 23 20:12:37.721 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  57  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:42.646 2009  to  Mon Mar 23 20:12:42.646 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0085106e-04 -3.3962727e-04 3.1927824e-03 -3.2901764e-03 -5.0125122e-03 -4.9331188e-03

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 20:41:59.448 2009  to  Mon Mar 23 20:42:08.643 2009   (  9.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PSF        command.setZernikes                                           Tue Mar 24 01:24:43.798 2009  to  Tue Mar 24 01:25:38.628 2009   ( 54.83) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  60  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:24:43.851 2009  to  Tue Mar 24 01:25:38.573 2009   ( 54.72) secs
                     right PSF ApplyZernikes failed

  61  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:24:44.013 2009  to  Tue Mar 24 01:25:38.518 2009   ( 54.50) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:24:47.176 2009  to  Tue Mar 24 01:25:38.460 2009   ( 51.28) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PSF        command.setInstrumentOffsets                                  Tue Mar 24 01:26:01.228 2009  to  Tue Mar 24 01:26:36.722 2009   ( 35.49) secs
                     right PSF SetInstrumentOffsets failed

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:26:01.334 2009  to  Tue Mar 24 01:26:36.611 2009   ( 35.28) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Mar 24 01:26:01.282 2009  to  Tue Mar 24 01:26:36.667 2009   ( 35.38) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:26:58.322 2009  to  Tue Mar 24 01:27:33.572 2009   ( 35.25) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:27:34.035 2009  to  Tue Mar 24 01:28:09.675 2009   ( 35.64) secs
                     right PSF ApplyZernikes failed

  68  SEQERROR  PSF        command.setZernikes                                           Tue Mar 24 01:27:33.982 2009  to  Tue Mar 24 01:28:07.876 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetZernikes started for 28 coefficients to ope M1
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  69  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:27:34.197 2009  to  Tue Mar 24 01:28:09.618 2009   ( 35.42) secs
                     right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  70  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:27:37.324 2009  to  Tue Mar 24 01:28:09.561 2009   ( 32.24) secs
                    Started event but no Complete event
                     right PSF SetZernikes started for 28 coefficients to ope M1
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  71  FAILED    PSF        command.setZernikes                                           Tue Mar 24 01:28:07.876 2009  to  Tue Mar 24 01:28:09.763 2009   (  1.89) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  72  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:28:09.819 2009  to  Tue Mar 24 01:28:10.828 2009   (  1.01) secs
                     right PSF ApplyZernikes failed

  73  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:28:09.982 2009  to  Tue Mar 24 01:28:10.772 2009   (  0.79) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

  74  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:28:10.536 2009  to  Tue Mar 24 01:28:10.715 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  75  SEQERROR  PSF        command.setZernikes                                           Tue Mar 24 01:28:10.885 2009  to  Tue Mar 24 01:28:10.885 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  76  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Tue Mar 24 01:31:33.951 2009  to  Tue Mar 24 01:31:34.246 2009   (  0.29) secs
                     right PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  77  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:31:34.004 2009  to  Tue Mar 24 01:31:34.190 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  78  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:40:05.371 2009  to  Tue Mar 24 01:43:23.923 2009   (198.55) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 03:07:38.307 2009  to  Tue Mar 24 03:07:50.926 2009   ( 12.62) secs
                     right PSF ApplyZernikes failed

  80  FAILED    PSF        command.setZernikes                                           Tue Mar 24 03:07:38.255 2009  to  Tue Mar 24 03:07:50.981 2009   ( 12.73) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  81  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 03:07:38.468 2009  to  Tue Mar 24 03:07:50.871 2009   ( 12.40) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:55:43.393 2009  to  Mon Mar 23 18:56:39.268 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   2  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:55:43.456 2009  to  Mon Mar 23 18:56:39.332 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

   3  FAILED    IIF        command.moveFocus                                             Mon Mar 23 18:56:39.101 2009  to  Mon Mar 23 18:56:39.734 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

   4  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 18:56:39.163 2009  to  Mon Mar 23 18:56:39.561 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

   5  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 18:56:39.215 2009  to  Mon Mar 23 18:56:39.505 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:56:39.268 2009  to  Mon Mar 23 18:56:39.449 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:56:39.332 2009  to  Mon Mar 23 18:56:39.386 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:56:41.623 2009  to  Mon Mar 23 18:56:41.623 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   9  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:56:41.684 2009  to  Mon Mar 23 18:56:41.684 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  10  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:41.111 2009  to  Mon Mar 23 18:58:44.417 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:41.178 2009  to  Mon Mar 23 18:58:44.480 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  12  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 18:58:44.312 2009  to  Mon Mar 23 18:58:44.713 2009   (  0.40) secs
                     left PSF SetInstrumentOffsets failed

  13  FAILED    IIF        command.moveFocus                                             Mon Mar 23 18:58:44.250 2009  to  Mon Mar 23 18:58:44.882 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

  14  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 18:58:44.365 2009  to  Mon Mar 23 18:58:44.657 2009   (  0.29) secs
                     left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:44.480 2009  to  Mon Mar 23 18:58:44.533 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:44.417 2009  to  Mon Mar 23 18:58:44.601 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 18:58:54.254 2009  to  Mon Mar 23 18:58:54.254 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  18  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 18:58:54.322 2009  to  Mon Mar 23 18:58:54.322 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  19  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:02:57.297 2009  to  Mon Mar 23 19:03:03.937 2009   (  6.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491408539351852e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

  20  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:02:57.364 2009  to  Mon Mar 23 19:03:03.769 2009   (  6.40) secs
                     right PSF SetInstrumentOffsets failed

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:02:57.470 2009  to  Mon Mar 23 19:03:03.659 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:02:57.417 2009  to  Mon Mar 23 19:03:03.714 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:02:57.533 2009  to  Mon Mar 23 19:03:03.596 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  SEQERROR  IIF        command.offset                                                Mon Mar 23 19:03:31.456 2009  to  Mon Mar 23 19:04:12.023 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command started for both LBC from IIF

  25  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:03:31.677 2009  to  Mon Mar 23 19:03:34.603 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:03:31.740 2009  to  Mon Mar 23 19:03:34.666 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

  27  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 23 19:03:32.141 2009  to  Mon Mar 23 19:04:12.622 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

  28  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:03:36.722 2009  to  Mon Mar 23 19:03:36.722 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  29  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:03:36.787 2009  to  Mon Mar 23 19:03:36.787 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  30  SEQERROR  IIF        command.offset.telescopeWait                                  Mon Mar 23 19:04:18.478 2009  to  Mon Mar 23 19:04:18.478 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command wait for telescope complete for both LBC

  31  SEQERROR  IIF        command.offset                                                Mon Mar 23 19:04:18.530 2009  to  Mon Mar 23 19:04:18.530 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Offset command complete for both LBC from IIF

  32  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:38.468 2009  to  Mon Mar 23 19:22:52.325 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  33  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:38.535 2009  to  Mon Mar 23 19:22:52.389 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  34  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:52.389 2009  to  Mon Mar 23 19:22:52.441 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:52.325 2009  to  Mon Mar 23 19:22:52.503 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  36  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:22:53.613 2009  to  Mon Mar 23 19:22:53.613 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  37  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:22:53.675 2009  to  Mon Mar 23 19:22:53.675 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  38  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 19:31:02.530 2009  to  Mon Mar 23 19:31:02.530 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Mon Mar 23 19:31:02.581 2009  to  Mon Mar 23 19:31:02.581 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  40  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:37:04.411 2009  to  Mon Mar 23 19:37:11.097 2009   (  6.69) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491410908564815e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  41  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:37:04.483 2009  to  Mon Mar 23 19:37:10.893 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  42  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:37:04.535 2009  to  Mon Mar 23 19:37:10.838 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  43  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:37:04.587 2009  to  Mon Mar 23 19:37:10.783 2009   (  6.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:37:04.649 2009  to  Mon Mar 23 19:37:10.716 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  45  FAILED    IIF        command.moveFocus                                             Mon Mar 23 19:41:13.953 2009  to  Mon Mar 23 19:41:20.592 2009   (  6.64) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491411197916666e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  46  FAILED    PSF        command.setInstrumentOffsets                                  Mon Mar 23 19:41:14.017 2009  to  Mon Mar 23 19:41:20.426 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  47  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Mar 23 19:41:14.070 2009  to  Mon Mar 23 19:41:20.369 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:41:14.123 2009  to  Mon Mar 23 19:41:20.314 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:41:14.185 2009  to  Mon Mar 23 19:41:20.250 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  50  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:28.612 2009  to  Mon Mar 23 19:46:41.186 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:28.856 2009  to  Mon Mar 23 19:46:44.325 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  52  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:28.920 2009  to  Mon Mar 23 19:46:44.386 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  FAILED    IIF        command.sendWavefront                                         Mon Mar 23 19:46:40.904 2009  to  Mon Mar 23 19:46:44.785 2009   (  3.88) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                     IIF SendWavefront command failed for right LBC for M1

  54  FAILED    PSF        command.setZernikes                                           Mon Mar 23 19:46:40.973 2009  to  Mon Mar 23 19:46:44.670 2009   (  3.70) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  55  FAILED    PSF        command.applyZernikes                                         Mon Mar 23 19:46:41.025 2009  to  Mon Mar 23 19:46:44.614 2009   (  3.59) secs
                     right PSF ApplyZernikes failed

  56  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:41.186 2009  to  Mon Mar 23 19:46:44.558 2009   (  3.37) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  57  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:44.325 2009  to  Mon Mar 23 19:46:44.503 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  58  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:44.386 2009  to  Mon Mar 23 19:46:44.439 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  59  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 19:46:45.002 2009  to  Mon Mar 23 19:46:45.002 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  60  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 19:46:45.071 2009  to  Mon Mar 23 19:46:45.071 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  61  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Mon Mar 23 19:46:45.128 2009  to  Mon Mar 23 19:46:45.128 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

  62  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:52.346 2009  to  Mon Mar 23 20:11:52.346 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -7.6138973e-04 -1.0121465e-03 3.0442476e-03 4.4746399e-03 3.0403137e-02 2.8483629e-02

  63  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.008 2009  to  Mon Mar 23 20:11:53.008 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  64  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.264 2009  to  Mon Mar 23 20:11:53.264 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  65  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.520 2009  to  Mon Mar 23 20:11:53.520 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  66  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:11:53.777 2009  to  Mon Mar 23 20:11:53.777 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:03.954 2009  to  Mon Mar 23 20:12:03.954 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  68  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:07.238 2009  to  Mon Mar 23 20:12:07.238 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  69  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:07.492 2009  to  Mon Mar 23 20:12:07.492 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  70  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:11.179 2009  to  Mon Mar 23 20:12:11.179 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.8145313e-04 -1.0187030e-03 3.0598640e-03 -4.0422440e-02 6.1340332e-03 8.1212521e-03

  71  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:11.434 2009  to  Mon Mar 23 20:12:11.434 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.8145313e-04 -1.0187030e-03 3.0598640e-03 -4.0422440e-02 6.1340332e-03 8.1212521e-03

  72  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:13.102 2009  to  Mon Mar 23 20:12:13.102 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6166439e-04 -7.2455406e-04 3.0434132e-03 -1.1168480e-02 5.7342529e-02 7.8518391e-03

  73  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:13.357 2009  to  Mon Mar 23 20:12:13.357 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.6166439e-04 -7.2455406e-04 3.0434132e-03 -1.1168480e-02 5.7342529e-02 7.8518391e-03

  74  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:17.462 2009  to  Mon Mar 23 20:12:17.462 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  75  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:17.717 2009  to  Mon Mar 23 20:12:17.717 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 4.4298172e-04 -7.2336197e-04 3.2415390e-03 -3.3857346e-02 2.7866364e-02 -2.1703243e-03

  76  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:19.393 2009  to  Mon Mar 23 20:12:19.393 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  77  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:19.648 2009  to  Mon Mar 23 20:12:19.648 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 2.6249886e-04 -4.2653084e-04 3.0540228e-03 -4.9894333e-02 4.4952393e-02 8.4536076e-03

  78  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:20.917 2009  to  Mon Mar 23 20:12:20.917 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  79  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:21.172 2009  to  Mon Mar 23 20:12:21.172 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  80  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:24.268 2009  to  Mon Mar 23 20:12:24.268 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  81  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:24.524 2009  to  Mon Mar 23 20:12:24.524 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  82  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:33.504 2009  to  Mon Mar 23 20:12:33.504 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  83  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:33.758 2009  to  Mon Mar 23 20:12:33.758 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.3722649e-04 -7.1412325e-04 3.0548573e-03 -3.4251213e-02 1.8013000e-02 2.9085875e-02

  84  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:37.466 2009  to  Mon Mar 23 20:12:37.466 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  85  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:37.721 2009  to  Mon Mar 23 20:12:37.721 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.4271011e-04 -1.3167262e-03 3.0492544e-03 -1.6965866e-03 1.8524170e-02 7.5194836e-03

  86  FAILED    PSF        primaryMirror.positionError                                   Mon Mar 23 20:12:42.646 2009  to  Mon Mar 23 20:12:42.646 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0085106e-04 -3.3962727e-04 3.1927824e-03 -3.2901764e-03 -5.0125122e-03 -4.9331188e-03

  87  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 20:32:01.961 2009  to  Mon Mar 23 20:32:01.961 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  88  FAILED    PMC        VxInterface.close                                             Mon Mar 23 20:32:02.013 2009  to  Mon Mar 23 20:32:02.013 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  89  FAILED    IIF        command.preset.(TRACK)                                        Mon Mar 23 20:41:56.901 2009  to  Mon Mar 23 20:42:08.769 2009   ( 11.87) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  90  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Mar 23 20:41:59.448 2009  to  Mon Mar 23 20:42:08.643 2009   (  9.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  91  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Mar 23 20:41:59.511 2009  to  Mon Mar 23 20:42:08.580 2009   (  9.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  92  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 23 20:56:13.179 2009  to  Mon Mar 23 20:56:13.179 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  93  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 23 20:56:13.232 2009  to  Mon Mar 23 20:56:13.232 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  94  FAILED    PMC        thermal.badReceive                                            Mon Mar 23 20:56:13.284 2009  to  Mon Mar 23 20:56:13.284 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  95  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 20:57:46.730 2009  to  Mon Mar 23 20:57:46.730 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  96  FAILED    PMC        VxInterface.close                                             Mon Mar 23 20:57:46.776 2009  to  Mon Mar 23 20:57:46.776 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  97  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:06:09.155 2009  to  Mon Mar 23 21:06:09.155 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  98  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:06:09.207 2009  to  Mon Mar 23 21:06:09.207 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  99  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:22:14.763 2009  to  Mon Mar 23 21:22:14.763 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 100  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:22:14.711 2009  to  Mon Mar 23 21:22:14.711 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 101  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:22:17.268 2009  to  Mon Mar 23 21:22:17.268 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:22:17.216 2009  to  Mon Mar 23 21:22:17.216 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 103  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:39:35.612 2009  to  Mon Mar 23 21:39:35.612 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 104  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:39:35.559 2009  to  Mon Mar 23 21:39:35.559 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 105  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:43:39.519 2009  to  Mon Mar 23 21:43:39.519 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 106  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:43:39.571 2009  to  Mon Mar 23 21:43:39.571 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 107  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 21:58:42.384 2009  to  Mon Mar 23 21:58:42.384 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 108  FAILED    PMC        VxInterface.close                                             Mon Mar 23 21:58:42.437 2009  to  Mon Mar 23 21:58:42.437 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 109  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:08:31.796 2009  to  Mon Mar 23 22:08:31.796 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 110  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:08:31.848 2009  to  Mon Mar 23 22:08:31.848 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 111  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:24:08.156 2009  to  Mon Mar 23 22:24:08.156 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 112  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:24:08.209 2009  to  Mon Mar 23 22:24:08.209 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 113  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 23 22:38:58.923 2009  to  Mon Mar 23 22:38:58.923 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 114  FAILED    PMC        VxInterface.close                                             Mon Mar 23 22:38:58.974 2009  to  Mon Mar 23 22:38:58.974 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 115  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:01:10.637 2009  to  Tue Mar 24 00:01:10.637 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 116  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:01:10.586 2009  to  Tue Mar 24 00:01:10.586 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 117  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:35:24.556 2009  to  Tue Mar 24 00:35:24.556 2009   (  0.00) secs
                     right PMC AirPressure length error: expected 100, got 96

 118  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:35:24.608 2009  to  Tue Mar 24 00:35:24.608 2009   (  0.00) secs
                     right PMC AirPressure closing network connection

 119  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:35:54.251 2009  to  Tue Mar 24 00:35:54.251 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 120  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:35:54.303 2009  to  Tue Mar 24 00:35:54.303 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 121  FAILED    PMC        VxInterface.close                                             Tue Mar 24 00:38:42.904 2009  to  Tue Mar 24 00:38:42.904 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 122  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 00:38:42.851 2009  to  Tue Mar 24 00:38:42.851 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 123  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 01:24:43.730 2009  to  Tue Mar 24 01:25:38.748 2009   ( 55.02) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 124  FAILED    PSF        command.setZernikes                                           Tue Mar 24 01:24:43.798 2009  to  Tue Mar 24 01:25:38.628 2009   ( 54.83) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 125  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:24:43.851 2009  to  Tue Mar 24 01:25:38.573 2009   ( 54.72) secs
                     right PSF ApplyZernikes failed

 126  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:24:44.013 2009  to  Tue Mar 24 01:25:38.518 2009   ( 54.50) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 127  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:24:47.176 2009  to  Tue Mar 24 01:25:38.460 2009   ( 51.28) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 128  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:24:47.240 2009  to  Tue Mar 24 01:25:38.392 2009   ( 51.15) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 129  FAILED    IIF        command.moveFocus                                             Tue Mar 24 01:26:01.092 2009  to  Tue Mar 24 01:26:36.890 2009   ( 35.80) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491435141203704e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 130  FAILED    PSF        command.setInstrumentOffsets                                  Tue Mar 24 01:26:01.228 2009  to  Tue Mar 24 01:26:36.722 2009   ( 35.49) secs
                     right PSF SetInstrumentOffsets failed

 131  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:26:01.334 2009  to  Tue Mar 24 01:26:36.611 2009   ( 35.28) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 132  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Mar 24 01:26:01.282 2009  to  Tue Mar 24 01:26:36.667 2009   ( 35.38) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 133  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:26:01.426 2009  to  Tue Mar 24 01:26:36.543 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 134  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:26:58.322 2009  to  Tue Mar 24 01:27:33.572 2009   ( 35.25) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 135  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:26:58.383 2009  to  Tue Mar 24 01:27:33.502 2009   ( 35.12) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 136  SEQERROR  IIF        command.sendWavefront                                         Tue Mar 24 01:27:33.915 2009  to  Tue Mar 24 01:28:07.810 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 137  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:27:34.035 2009  to  Tue Mar 24 01:28:09.675 2009   ( 35.64) secs
                     right PSF ApplyZernikes failed

 138  SEQERROR  PSF        command.setZernikes                                           Tue Mar 24 01:27:33.982 2009  to  Tue Mar 24 01:28:07.876 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF SetZernikes started for 28 coefficients to ope M1
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 139  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:27:34.197 2009  to  Tue Mar 24 01:28:09.618 2009   ( 35.42) secs
                     right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

 140  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:27:37.324 2009  to  Tue Mar 24 01:28:09.561 2009   ( 32.24) secs
                    Started event but no Complete event
                     right PSF SetZernikes started for 28 coefficients to ope M1
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 141  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:27:37.384 2009  to  Tue Mar 24 01:28:09.496 2009   ( 32.11) secs
                     right PMC ** PANIC: Hardpoint breakaway
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 142  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 01:28:07.810 2009  to  Tue Mar 24 01:28:09.935 2009   (  2.12) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 143  FAILED    PSF        command.setZernikes                                           Tue Mar 24 01:28:07.876 2009  to  Tue Mar 24 01:28:09.763 2009   (  1.89) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 144  FAILED    PMC        mirror.panic                                                  Tue Mar 24 01:28:09.475 2009  to  Tue Mar 24 01:28:09.475 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 145  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 01:28:09.819 2009  to  Tue Mar 24 01:28:10.828 2009   (  1.01) secs
                     right PSF ApplyZernikes failed

 146  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 01:28:09.982 2009  to  Tue Mar 24 01:28:10.772 2009   (  0.79) secs
                     right PSF primary mirror force adjustments failed because right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 147  FAILED    PMC        actuator.command.changeOffsets.all                            Tue Mar 24 01:28:10.417 2009  to  Tue Mar 24 01:28:10.470 2009   (  0.05) secs
                     right PMC Actuator ChangeAllOffsets Command Started
                     right PMC Actuator ChangeAllOffsets Command Failed because Wrong mirror state

 148  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:28:10.597 2009  to  Tue Mar 24 01:28:10.650 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 149  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:28:10.536 2009  to  Tue Mar 24 01:28:10.715 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 150  SEQERROR  PSF        command.setZernikes                                           Tue Mar 24 01:28:10.885 2009  to  Tue Mar 24 01:28:10.885 2009   (  0.00) secs
                    Failed event but no Started event
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 151  SEQERROR  IIF        command.sendWavefront                                         Tue Mar 24 01:28:11.109 2009  to  Tue Mar 24 01:28:11.109 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF SendWavefront command failed for right LBC for M1

 152  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Tue Mar 24 01:31:33.951 2009  to  Tue Mar 24 01:31:34.246 2009   (  0.29) secs
                     right PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

 153  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:31:34.065 2009  to  Tue Mar 24 01:31:34.120 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 154  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:31:34.004 2009  to  Tue Mar 24 01:31:34.190 2009   (  0.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 155  FAILED    PMC        actuator.command.activate.all                                 Tue Mar 24 01:34:20.360 2009  to  Tue Mar 24 01:34:20.414 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

 156  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Mar 24 01:40:05.371 2009  to  Tue Mar 24 01:43:23.923 2009   (198.55) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 157  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Mar 24 01:40:05.434 2009  to  Tue Mar 24 01:43:23.856 2009   (198.42) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 158  FAILED    PMC        mirror.panic                                                  Tue Mar 24 01:44:06.652 2009  to  Tue Mar 24 01:44:06.652 2009   (  0.00) secs
                     right PMC ** PANIC: Hardpoint breakaway

 159  FAILED    PMC        actuator.command.activate.all                                 Tue Mar 24 01:57:13.853 2009  to  Tue Mar 24 01:57:13.907 2009   (  0.05) secs
                     right PMC Actuator Activate All Command Started
                     right PMC Actuator Activate All Command Failed because Wrong cell state

 160  FAILED    PMC        actuator.forceMonitor2.panic                                  Tue Mar 24 01:59:30.016 2009  to  Tue Mar 24 01:59:30.016 2009   (  0.00) secs
                     right PMC Actuator 210 force monitor 2 PANIC! 165.8 lbs, limit is 64.1

 161  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:09:16.093 2009  to  Tue Mar 24 02:09:16.093 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 162  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:09:16.041 2009  to  Tue Mar 24 02:09:16.041 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 163  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:19:01.018 2009  to  Tue Mar 24 02:19:01.018 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 164  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:19:01.071 2009  to  Tue Mar 24 02:19:01.071 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 165  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:19:01.518 2009  to  Tue Mar 24 02:19:01.518 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

 166  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:19:01.571 2009  to  Tue Mar 24 02:19:01.571 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

 167  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:28:40.783 2009  to  Tue Mar 24 02:28:40.783 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 168  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:28:40.731 2009  to  Tue Mar 24 02:28:40.731 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 169  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 02:48:19.590 2009  to  Tue Mar 24 02:48:19.590 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 170  FAILED    PMC        VxInterface.close                                             Tue Mar 24 02:48:19.641 2009  to  Tue Mar 24 02:48:19.641 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 171  FAILED    IIF        command.sendWavefront                                         Tue Mar 24 03:07:38.182 2009  to  Tue Mar 24 03:07:51.097 2009   ( 12.92) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 172  FAILED    PSF        command.applyZernikes                                         Tue Mar 24 03:07:38.307 2009  to  Tue Mar 24 03:07:50.926 2009   ( 12.62) secs
                     right PSF ApplyZernikes failed

 173  FAILED    PSF        command.setZernikes                                           Tue Mar 24 03:07:38.255 2009  to  Tue Mar 24 03:07:50.981 2009   ( 12.73) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 174  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Mar 24 03:07:38.468 2009  to  Tue Mar 24 03:07:50.871 2009   ( 12.40) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 175  FAILED    PMC        VxInterface.close                                             Tue Mar 24 03:18:41.868 2009  to  Tue Mar 24 03:18:41.868 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 176  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 24 03:18:41.817 2009  to  Tue Mar 24 03:18:41.817 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 177  FAILED    PMC        VxInterface.packetReadError                                   Tue Mar 24 03:19:33.454 2009  to  Tue Mar 24 03:19:33.454 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 178  FAILED    PMC        VxInterface.selectTimeout                                     Tue Mar 24 03:19:33.402 2009  to  Tue Mar 24 03:19:33.402 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 179  FAILED    PMC        thermal.badReceive                                            Tue Mar 24 03:19:33.506 2009  to  Tue Mar 24 03:19:33.506 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 180  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 24 03:31:49.982 2009  to  Tue Mar 24 03:31:51.686 2009   (  1.70) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491443878472222e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS reports MCSPU error returned - BAD Poly:last poly t0 = 4744607545.004 which is > current poly t0 = 4744607544.
                     IIF Preset command failed for both LBC mode TRACK from IIF

 181  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:50.417 2009  to  Tue Mar 24 03:31:50.417 2009   (  0.00) secs
                     EL bad poly no. 1: BAD Poly: EL = -9.358467e-03 rad. Too low.

 182  FAILED    PCS        telescope.command.startTracking                               Tue Mar 24 03:31:50.713 2009  to  Tue Mar 24 03:31:51.112 2009   (  0.40) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - BAD Poly:last poly t0 = 4744607545.004 which is > current poly t0 = 4744607544.

 183  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 24 03:31:51.421 2009  to  Tue Mar 24 03:31:51.421 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 184  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:53.452 2009  to  Tue Mar 24 03:31:53.452 2009   (  0.00) secs
                     EL bad poly no. 41: BAD Poly: EL = -1.895775e-02 rad. Too low.

 185  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:56.503 2009  to  Tue Mar 24 03:31:56.503 2009   (  0.00) secs
                     EL bad poly no. 102: BAD Poly: EL = -1.576364e-02 rad. Too low.

 186  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:31:59.526 2009  to  Tue Mar 24 03:31:59.526 2009   (  0.00) secs
                     EL bad poly no. 152: BAD Poly: EL = -1.514399e-02 rad. Too low.

 187  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:02.545 2009  to  Tue Mar 24 03:32:02.545 2009   (  0.00) secs
                     EL bad poly no. 183: BAD Poly: EL = -1.528635e-02 rad. Too low.

 188  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:05.635 2009  to  Tue Mar 24 03:32:05.635 2009   (  0.00) secs
                     EL bad poly no. 214: BAD Poly: EL = -1.531917e-02 rad. Too low.

 189  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:08.716 2009  to  Tue Mar 24 03:32:08.716 2009   (  0.00) secs
                     EL bad poly no. 245: BAD Poly: EL = -1.531142e-02 rad. Too low.

 190  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:11.761 2009  to  Tue Mar 24 03:32:11.761 2009   (  0.00) secs
                     EL bad poly no. 278: BAD Poly: EL = -1.530964e-02 rad. Too low.

 191  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:14.771 2009  to  Tue Mar 24 03:32:14.771 2009   (  0.00) secs
                     EL bad poly no. 325: BAD Poly: EL = -1.531007e-02 rad. Too low.

 192  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:17.775 2009  to  Tue Mar 24 03:32:17.775 2009   (  0.00) secs
                     EL bad poly no. 385: BAD Poly: EL = -1.531019e-02 rad. Too low.

 193  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:20.825 2009  to  Tue Mar 24 03:32:20.825 2009   (  0.00) secs
                     EL bad poly no. 446: BAD Poly: EL = -1.531020e-02 rad. Too low.

 194  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:23.826 2009  to  Tue Mar 24 03:32:23.826 2009   (  0.00) secs
                     EL bad poly no. 506: BAD Poly: EL = -1.531025e-02 rad. Too low.

 195  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:26.874 2009  to  Tue Mar 24 03:32:26.874 2009   (  0.00) secs
                     EL bad poly no. 567: BAD Poly: EL = -1.531034e-02 rad. Too low.

 196  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:29.874 2009  to  Tue Mar 24 03:32:29.874 2009   (  0.00) secs
                     EL bad poly no. 627: BAD Poly: EL = -1.531041e-02 rad. Too low.

 197  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:32.874 2009  to  Tue Mar 24 03:32:32.874 2009   (  0.00) secs
                     EL bad poly no. 687: BAD Poly: EL = -1.531053e-02 rad. Too low.

 198  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:35.876 2009  to  Tue Mar 24 03:32:35.876 2009   (  0.00) secs
                     EL bad poly no. 747: BAD Poly: EL = -1.531063e-02 rad. Too low.

 199  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:38.926 2009  to  Tue Mar 24 03:32:38.926 2009   (  0.00) secs
                     EL bad poly no. 808: BAD Poly: EL = -1.531078e-02 rad. Too low.

 200  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:41.927 2009  to  Tue Mar 24 03:32:41.927 2009   (  0.00) secs
                     EL bad poly no. 868: BAD Poly: EL = -1.531090e-02 rad. Too low.

 201  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:44.978 2009  to  Tue Mar 24 03:32:44.978 2009   (  0.00) secs
                     EL bad poly no. 929: BAD Poly: EL = -1.531119e-02 rad. Too low.

 202  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:48.029 2009  to  Tue Mar 24 03:32:48.029 2009   (  0.00) secs
                     EL bad poly no. 990: BAD Poly: EL = -1.531132e-02 rad. Too low.

 203  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:51.077 2009  to  Tue Mar 24 03:32:51.077 2009   (  0.00) secs
                     EL bad poly no. 1051: BAD Poly: EL = -1.531154e-02 rad. Too low.

 204  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:54.126 2009  to  Tue Mar 24 03:32:54.126 2009   (  0.00) secs
                     EL bad poly no. 1112: BAD Poly: EL = -1.531172e-02 rad. Too low.

 205  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:32:57.137 2009  to  Tue Mar 24 03:32:57.137 2009   (  0.00) secs
                     EL bad poly no. 1170: BAD Poly: EL = -1.531198e-02 rad. Too low.

 206  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:33:00.181 2009  to  Tue Mar 24 03:33:00.181 2009   (  0.00) secs
                     EL bad poly no. 1224: BAD Poly: EL = -1.531225e-02 rad. Too low.

 207  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 24 03:33:03.184 2009  to  Tue Mar 24 03:33:03.184 2009   (  0.00) secs
                     EL bad poly no. 1278: BAD Poly: EL = -1.531248e-02 rad. Too low.

**********************************************************