You are here: Foswiki>Software Web>TCSSWReportFile_090321 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 21 2009 to Mar 22 2009
 
    Reporting period beginning:   Sat Mar 21 18:01:02.417 2009
    Reporting period ending:      Sun Mar 22 06:50:51.094 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.04    0.10   100.0 %        176        176                      
                                                                       0.01    0.05    0.04    0.10
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.22    0.31    0.22    3.41   100.0 %        234        234                      
                                                                       0.22    0.31    0.22    3.41
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.16    0.20    0.14    3.18   100.0 %        477        477                      
                                                                       0.16    0.20    0.14    3.18
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.98    6.50    2.52   20.64   100.0 %        234        234                      
                                                                       4.98    6.50    2.52   20.64
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   10.06   25.79    7.56   39.52   100.0 %         11         11                      
                                                                      10.06   25.79    7.56   39.52
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    5.48   10.16    1.05   17.09   100.0 %         11         11                      
                                                                       5.48   10.16    1.05   17.09
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    7.67    5.89    1.05   23.09   100.0 %         11         11                      
                                                                       7.67    5.89    1.05   23.09
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    5.74    6.11    0.69   55.26    99.6 %        766        763          3           
                                                                       5.71    6.08    0.69   55.26
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.54    4.48    2.53    7.53    98.6 %         73         72          1           
                                                                       1.52    4.45    2.53    7.53

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            18

IIF Events of Interest

   1  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 20:51:55.474 2009  to  Sat Mar 21 20:52:02.482 2009   (  7.01) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

   2  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 22:38:28.889 2009  to  Sat Mar 21 22:38:39.844 2009   ( 10.96) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   3  FAILED    IIF        command.sendWavefront                                         Sun Mar 22 01:56:50.472 2009  to  Sun Mar 22 01:57:14.424 2009   ( 23.95) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   4  FAILED    IIF        command.stepFocus                                             Sun Mar 22 02:48:04.182 2009  to  Sun Mar 22 02:48:10.817 2009   (  6.63) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3809                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7618                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                    17                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.damper.command.open . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.damper.command.setState . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     178                      
     instrumentCooling.badWeatherData . . . . . . . . . . . . . . .                             2
     hydraulicBearing.badWeatherData. . . . . . . . . . . . . . . .                             2

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       7                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       5                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               1220           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       5                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             6
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      34                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            22
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      46                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      46                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     138                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      46                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:02.417 2009  to  Sat Mar 21 18:01:02.417 2009   (  0.00) secs
                     EL bad poly no. 404701: BAD Poly: EL = -5.481066e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:05.452 2009  to  Sat Mar 21 18:01:05.452 2009   (  0.00) secs
                     EL bad poly no. 404754: BAD Poly: EL = -5.480724e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:08.443 2009  to  Sat Mar 21 18:01:08.443 2009   (  0.00) secs
                     EL bad poly no. 404807: BAD Poly: EL = -5.480386e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:11.474 2009  to  Sat Mar 21 18:01:11.474 2009   (  0.00) secs
                     EL bad poly no. 404860: BAD Poly: EL = -5.480043e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:14.496 2009  to  Sat Mar 21 18:01:14.496 2009   (  0.00) secs
                     EL bad poly no. 404913: BAD Poly: EL = -5.479700e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:17.547 2009  to  Sat Mar 21 18:01:17.547 2009   (  0.00) secs
                     EL bad poly no. 404967: BAD Poly: EL = -5.479354e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:20.591 2009  to  Sat Mar 21 18:01:20.591 2009   (  0.00) secs
                     EL bad poly no. 405019: BAD Poly: EL = -5.479008e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:23.610 2009  to  Sat Mar 21 18:01:23.610 2009   (  0.00) secs
                     EL bad poly no. 405073: BAD Poly: EL = -5.478665e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:26.621 2009  to  Sat Mar 21 18:01:26.621 2009   (  0.00) secs
                     EL bad poly no. 405124: BAD Poly: EL = -5.478322e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:29.648 2009  to  Sat Mar 21 18:01:29.648 2009   (  0.00) secs
                     EL bad poly no. 405178: BAD Poly: EL = -5.477977e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:32.702 2009  to  Sat Mar 21 18:01:32.702 2009   (  0.00) secs
                     EL bad poly no. 405230: BAD Poly: EL = -5.477628e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:35.720 2009  to  Sat Mar 21 18:01:35.720 2009   (  0.00) secs
                     EL bad poly no. 405281: BAD Poly: EL = -5.477283e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:38.784 2009  to  Sat Mar 21 18:01:38.784 2009   (  0.00) secs
                     EL bad poly no. 405333: BAD Poly: EL = -5.476933e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:41.837 2009  to  Sat Mar 21 18:01:41.837 2009   (  0.00) secs
                     EL bad poly no. 405385: BAD Poly: EL = -5.476583e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:44.849 2009  to  Sat Mar 21 18:01:44.849 2009   (  0.00) secs
                     EL bad poly no. 405436: BAD Poly: EL = -5.476237e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:47.865 2009  to  Sat Mar 21 18:01:47.865 2009   (  0.00) secs
                     EL bad poly no. 405487: BAD Poly: EL = -5.475891e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:50.865 2009  to  Sat Mar 21 18:01:50.865 2009   (  0.00) secs
                     EL bad poly no. 405537: BAD Poly: EL = -5.475546e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:53.909 2009  to  Sat Mar 21 18:01:53.909 2009   (  0.00) secs
                     EL bad poly no. 405590: BAD Poly: EL = -5.475195e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:56.955 2009  to  Sat Mar 21 18:01:56.955 2009   (  0.00) secs
                     EL bad poly no. 405640: BAD Poly: EL = -5.474844e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:00.005 2009  to  Sat Mar 21 18:02:00.005 2009   (  0.00) secs
                     EL bad poly no. 405692: BAD Poly: EL = -5.474492e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:03.018 2009  to  Sat Mar 21 18:02:03.018 2009   (  0.00) secs
                     EL bad poly no. 405742: BAD Poly: EL = -5.474144e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:06.023 2009  to  Sat Mar 21 18:02:06.023 2009   (  0.00) secs
                     EL bad poly no. 405794: BAD Poly: EL = -5.473796e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:09.071 2009  to  Sat Mar 21 18:02:09.071 2009   (  0.00) secs
                     EL bad poly no. 405844: BAD Poly: EL = -5.473443e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:12.090 2009  to  Sat Mar 21 18:02:12.090 2009   (  0.00) secs
                     EL bad poly no. 405895: BAD Poly: EL = -5.473093e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:15.140 2009  to  Sat Mar 21 18:02:15.140 2009   (  0.00) secs
                     EL bad poly no. 405947: BAD Poly: EL = -5.472739e-01 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.14    0.06    0.04    3.06   100.0 %        477        477                      
                                                                       0.14    0.06    0.04    3.06
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.14    0.11    0.20   100.0 %        234        234                      
                                                                       0.02    0.14    0.11    0.20
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.10    0.10    0.05    0.54   100.0 %         23         23                      
                                                                       0.10    0.10    0.05    0.54
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.24    0.62    0.30    0.84   100.0 %         23         23                      
                                                                       0.24    0.62    0.30    0.84

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           

PCS Events of Interest

   1  FAILED    PCS        telescope.telemetryError                                      Sat Mar 21 19:02:35.430 2009  to  Sat Mar 21 19:02:35.430 2009   (  0.00) secs
                     PCS Telescope telemetry error: 2006: MySQL server has gone away

   2  FAILED    PCS        guider.telemetryError                                         Sat Mar 21 20:45:18.359 2009  to  Sat Mar 21 20:45:18.359 2009   (  0.00) secs
                     PCS Guider telemetry error: 2006: MySQL server has gone away
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.06    1.06    1.06   100.0 %          1          1                      
                                                                       0.00    1.06    1.06    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.31    2.86    2.05   11.07   100.0 %        169        169                      
                                                                       1.31    2.86    2.05   11.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.95    2.36    2.05    5.06   100.0 %         10         10                      
                                                                       0.95    2.36    2.05    5.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.05    5.05    5.05   100.0 %          1          1                      
                                                                       0.00    5.05    5.05    5.05
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.16   66.16   66.16   100.0 %          1          1                      
                                                                       0.00   66.16   66.16   66.16
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.27    5.50    0.00  103.25    99.5 %       1059       1054          5           
                                                                       6.93    5.42    2.05  103.25
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  304.76  304.76  304.76   100.0 %          1          1                      
                                                                       0.00  304.76  304.76  304.76
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.08    0.08    0.08   100.0 %          1          1                      
                                                                       0.00    0.08    0.08    0.08
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.07   100.0 %          4          4                      
                                                                       0.01    0.06    0.05    0.07

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             6
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .      10                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                            24
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                            24
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                            15
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             2
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 31           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 31           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      31                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     169                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           142
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            39
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                             5

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 18:33:58.245 2009  to  Sat Mar 21 18:35:15.443 2009   ( 77.20) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.panic                                                  Sat Mar 21 18:35:15.097 2009  to  Sat Mar 21 18:35:15.097 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

   3  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 18:50:39.659 2009  to  Sat Mar 21 18:50:39.659 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   4  FAILED    PMC        VxInterface.close                                             Sat Mar 21 18:50:39.710 2009  to  Sat Mar 21 18:50:39.710 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 19:41:18.635 2009  to  Sat Mar 21 19:41:18.635 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

   6  FAILED    PMC        VxInterface.close                                             Sat Mar 21 19:41:18.686 2009  to  Sat Mar 21 19:41:18.686 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

   7  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:20:45.214 2009  to  Sat Mar 21 20:20:45.214 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:20:45.162 2009  to  Sat Mar 21 20:20:45.162 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:21:00.759 2009  to  Sat Mar 21 20:21:00.759 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  10  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:21:00.811 2009  to  Sat Mar 21 20:21:00.811 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  11  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:23:21.692 2009  to  Sat Mar 21 20:23:21.692 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:23:21.638 2009  to  Sat Mar 21 20:23:21.638 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  13  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:49:44.326 2009  to  Sat Mar 21 20:49:44.422 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  14  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:49:50.390 2009  to  Sat Mar 21 20:49:50.390 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:51:56.062 2009  to  Sat Mar 21 20:52:02.126 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:52:20.242 2009  to  Sat Mar 21 20:52:20.242 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:52:20.190 2009  to  Sat Mar 21 20:52:20.190 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  18  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:14:28.188 2009  to  Sat Mar 21 21:14:28.188 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  19  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:14:28.240 2009  to  Sat Mar 21 21:14:28.240 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  20  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:34:49.541 2009  to  Sat Mar 21 21:34:49.541 2009   (  0.00) secs
                     left PMC PMC closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:34:49.489 2009  to  Sat Mar 21 21:34:49.489 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

  22  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:48:48.576 2009  to  Sat Mar 21 21:48:48.576 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:48:48.628 2009  to  Sat Mar 21 21:48:48.628 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:54:53.021 2009  to  Sat Mar 21 21:54:53.021 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:54:53.073 2009  to  Sat Mar 21 21:54:53.073 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:06:31.401 2009  to  Sat Mar 21 22:06:31.401 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:06:31.453 2009  to  Sat Mar 21 22:06:31.453 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:23:27.947 2009  to  Sat Mar 21 22:23:27.947 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:23:27.999 2009  to  Sat Mar 21 22:23:27.999 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  30  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 22:38:32.425 2009  to  Sat Mar 21 22:38:39.489 2009   (  7.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:41:50.580 2009  to  Sat Mar 21 22:41:50.580 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:41:50.633 2009  to  Sat Mar 21 22:41:50.633 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:51:22.493 2009  to  Sat Mar 21 22:51:22.493 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  34  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:51:22.546 2009  to  Sat Mar 21 22:51:22.546 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:04:37.473 2009  to  Sat Mar 21 23:04:37.473 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:04:37.525 2009  to  Sat Mar 21 23:04:37.525 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:09:08.132 2009  to  Sat Mar 21 23:09:08.132 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  38  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:09:08.184 2009  to  Sat Mar 21 23:09:08.184 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:38:33.465 2009  to  Sat Mar 21 23:38:33.465 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:38:33.517 2009  to  Sat Mar 21 23:38:33.517 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:48:14.677 2009  to  Sat Mar 21 23:48:14.677 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:48:14.730 2009  to  Sat Mar 21 23:48:14.730 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:06:03.716 2009  to  Sun Mar 22 00:06:03.716 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:06:03.769 2009  to  Sun Mar 22 00:06:03.769 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  45  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:07:41.852 2009  to  Sun Mar 22 00:07:41.852 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  46  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:07:41.801 2009  to  Sun Mar 22 00:07:41.801 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  47  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:09:54.481 2009  to  Sun Mar 22 00:09:54.481 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:09:54.532 2009  to  Sun Mar 22 00:09:54.532 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:19:18.061 2009  to  Sun Mar 22 00:19:18.061 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:19:18.010 2009  to  Sun Mar 22 00:19:18.010 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:47:10.743 2009  to  Sun Mar 22 00:47:10.743 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:47:10.795 2009  to  Sun Mar 22 00:47:10.795 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:51:53.553 2009  to  Sun Mar 22 00:51:53.553 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:51:53.500 2009  to  Sun Mar 22 00:51:53.500 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Sun Mar 22 01:16:46.742 2009  to  Sun Mar 22 01:16:46.742 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  56  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 01:16:46.690 2009  to  Sun Mar 22 01:16:46.690 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 22 01:56:53.976 2009  to  Sun Mar 22 01:57:14.064 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 22 02:48:04.412 2009  to  Sun Mar 22 02:48:10.474 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    5.74    5.85    0.45   55.02    99.6 %        766        763          3           
                                                                       5.71    5.82    0.45   55.02
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.11   100.0 %         22         22                      
                                                                       0.01    0.06    0.05    0.11
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.49    5.88    2.39   20.50    99.7 %        307        306          1           
                                                                       4.50    5.88    2.39   20.50
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    5.74    5.97    0.56   55.13    99.6 %        766        763          3           
                                                                       5.71    5.94    0.56   55.13
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    5.80    5.72    0.24   54.80    99.6 %        783        780          3           
                                                                       5.77    5.69    0.24   54.80
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.27    5.65    0.00  103.38    99.5 %       1059       1054          5           
                                                                       6.93    5.57    2.18  103.38
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.94    2.52    2.19    5.20   100.0 %         10         10                      
                                                                       0.94    2.52    2.19    5.20
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.10    0.06    0.54   100.0 %        287        287                      
                                                                       0.04    0.10    0.06    0.54
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.16    0.16    0.16   100.0 %          1          1                      
                                                                       0.00    0.16    0.16    0.16
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   40.26   68.52   11.56  105.75    80.0 %          5          4          1           
                                                                      45.92   65.70   11.56  105.75
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.49    5.76    2.29   20.39    99.7 %        307        306          1           
                                                                       4.50    5.76    2.29   20.39
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.06    0.05    0.08   100.0 %         23         23                      
                                                                       0.01    0.06    0.05    0.08
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.11    0.06    0.05    3.05   100.0 %        789        789                      
                                                                       0.11    0.06    0.05    3.05

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     primaryMirror.positionError. . . . . . . . . . . . . . . . . .                  6           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Sat Mar 21 18:33:55.762 2009  to  Sat Mar 21 18:35:15.568 2009   ( 79.81) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 18:33:58.184 2009  to  Sat Mar 21 18:35:15.512 2009   ( 77.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   3  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:47:25.504 2009  to  Sat Mar 21 20:47:25.504 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.4964342e-03 1.8435717e-03 -1.7102361e-03 -1.1053658e-01 1.5119171e-01 7.3651969e-02

   4  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:47:25.758 2009  to  Sat Mar 21 20:47:25.758 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.4964342e-03 1.8435717e-03 -1.7102361e-03 -1.1053658e-01 1.5119171e-01 7.3651969e-02

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:49:44.258 2009  to  Sat Mar 21 20:49:44.361 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

   6  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:49:50.456 2009  to  Sat Mar 21 20:49:50.456 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   7  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:50:46.726 2009  to  Sat Mar 21 20:50:46.726 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0661483e-03 2.2869110e-03 -1.4009476e-03 -1.3487625e-01 1.7007446e-01 8.8093638e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:50:46.980 2009  to  Sat Mar 21 20:50:46.980 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0661483e-03 2.2869110e-03 -1.4009476e-03 -1.3487625e-01 1.7007446e-01 8.8093638e-02

   9  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 20:51:55.596 2009  to  Sat Mar 21 20:52:02.309 2009   (  6.71) secs
                     left PSF ApplyZernikes failed

  10  FAILED    PSF        command.setZernikes                                           Sat Mar 21 20:51:55.543 2009  to  Sat Mar 21 20:52:02.365 2009   (  6.82) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  11  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 20:51:55.759 2009  to  Sat Mar 21 20:52:02.253 2009   (  6.49) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:51:55.998 2009  to  Sat Mar 21 20:52:02.194 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PSF        command.setZernikes                                           Sat Mar 21 22:38:28.960 2009  to  Sat Mar 21 22:38:39.727 2009   ( 10.77) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  14  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 22:38:29.012 2009  to  Sat Mar 21 22:38:39.671 2009   ( 10.66) secs
                     right PSF ApplyZernikes failed

  15  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 22:38:29.173 2009  to  Sat Mar 21 22:38:39.615 2009   ( 10.44) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 22:38:32.360 2009  to  Sat Mar 21 22:38:39.559 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PSF        command.setZernikes                                           Sun Mar 22 01:56:50.543 2009  to  Sun Mar 22 01:57:14.305 2009   ( 23.76) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  18  FAILED    PSF        command.applyZernikes                                         Sun Mar 22 01:56:50.596 2009  to  Sun Mar 22 01:57:14.248 2009   ( 23.65) secs
                     right PSF ApplyZernikes failed

  19  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Mar 22 01:56:50.757 2009  to  Sun Mar 22 01:57:14.192 2009   ( 23.43) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 22 01:56:53.914 2009  to  Sun Mar 22 01:57:14.135 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PSF        command.setInstrumentOffsets                                  Sun Mar 22 02:48:04.247 2009  to  Sun Mar 22 02:48:10.649 2009   (  6.40) secs
                     right PSF SetInstrumentOffsets failed

  22  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Mar 22 02:48:04.300 2009  to  Sun Mar 22 02:48:10.593 2009   (  6.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  23  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 22 02:48:04.352 2009  to  Sun Mar 22 02:48:10.538 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 22 03:01:06.463 2009  to  Sun Mar 22 03:01:06.463 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.8057823e-03 -2.9885769e-04 1.6062856e-03 -1.5729475e-01 5.0819397e-02 6.2399387e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 22 03:01:06.719 2009  to  Sun Mar 22 03:01:06.719 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.8057823e-03 -2.9885769e-04 1.6062856e-03 -1.5729475e-01 5.0819397e-02 6.2399387e-02
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:02.417 2009  to  Sat Mar 21 18:01:02.417 2009   (  0.00) secs
                     EL bad poly no. 404701: BAD Poly: EL = -5.481066e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:05.452 2009  to  Sat Mar 21 18:01:05.452 2009   (  0.00) secs
                     EL bad poly no. 404754: BAD Poly: EL = -5.480724e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:08.443 2009  to  Sat Mar 21 18:01:08.443 2009   (  0.00) secs
                     EL bad poly no. 404807: BAD Poly: EL = -5.480386e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:11.474 2009  to  Sat Mar 21 18:01:11.474 2009   (  0.00) secs
                     EL bad poly no. 404860: BAD Poly: EL = -5.480043e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:14.496 2009  to  Sat Mar 21 18:01:14.496 2009   (  0.00) secs
                     EL bad poly no. 404913: BAD Poly: EL = -5.479700e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:17.547 2009  to  Sat Mar 21 18:01:17.547 2009   (  0.00) secs
                     EL bad poly no. 404967: BAD Poly: EL = -5.479354e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:20.591 2009  to  Sat Mar 21 18:01:20.591 2009   (  0.00) secs
                     EL bad poly no. 405019: BAD Poly: EL = -5.479008e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:23.610 2009  to  Sat Mar 21 18:01:23.610 2009   (  0.00) secs
                     EL bad poly no. 405073: BAD Poly: EL = -5.478665e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:26.621 2009  to  Sat Mar 21 18:01:26.621 2009   (  0.00) secs
                     EL bad poly no. 405124: BAD Poly: EL = -5.478322e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:29.648 2009  to  Sat Mar 21 18:01:29.648 2009   (  0.00) secs
                     EL bad poly no. 405178: BAD Poly: EL = -5.477977e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:32.702 2009  to  Sat Mar 21 18:01:32.702 2009   (  0.00) secs
                     EL bad poly no. 405230: BAD Poly: EL = -5.477628e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:35.720 2009  to  Sat Mar 21 18:01:35.720 2009   (  0.00) secs
                     EL bad poly no. 405281: BAD Poly: EL = -5.477283e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:38.784 2009  to  Sat Mar 21 18:01:38.784 2009   (  0.00) secs
                     EL bad poly no. 405333: BAD Poly: EL = -5.476933e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:41.837 2009  to  Sat Mar 21 18:01:41.837 2009   (  0.00) secs
                     EL bad poly no. 405385: BAD Poly: EL = -5.476583e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:44.849 2009  to  Sat Mar 21 18:01:44.849 2009   (  0.00) secs
                     EL bad poly no. 405436: BAD Poly: EL = -5.476237e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:47.865 2009  to  Sat Mar 21 18:01:47.865 2009   (  0.00) secs
                     EL bad poly no. 405487: BAD Poly: EL = -5.475891e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:50.865 2009  to  Sat Mar 21 18:01:50.865 2009   (  0.00) secs
                     EL bad poly no. 405537: BAD Poly: EL = -5.475546e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:53.909 2009  to  Sat Mar 21 18:01:53.909 2009   (  0.00) secs
                     EL bad poly no. 405590: BAD Poly: EL = -5.475195e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:01:56.955 2009  to  Sat Mar 21 18:01:56.955 2009   (  0.00) secs
                     EL bad poly no. 405640: BAD Poly: EL = -5.474844e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:00.005 2009  to  Sat Mar 21 18:02:00.005 2009   (  0.00) secs
                     EL bad poly no. 405692: BAD Poly: EL = -5.474492e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:03.018 2009  to  Sat Mar 21 18:02:03.018 2009   (  0.00) secs
                     EL bad poly no. 405742: BAD Poly: EL = -5.474144e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:06.023 2009  to  Sat Mar 21 18:02:06.023 2009   (  0.00) secs
                     EL bad poly no. 405794: BAD Poly: EL = -5.473796e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:09.071 2009  to  Sat Mar 21 18:02:09.071 2009   (  0.00) secs
                     EL bad poly no. 405844: BAD Poly: EL = -5.473443e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:12.090 2009  to  Sat Mar 21 18:02:12.090 2009   (  0.00) secs
                     EL bad poly no. 405895: BAD Poly: EL = -5.473093e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Mar 21 18:02:15.140 2009  to  Sat Mar 21 18:02:15.140 2009   (  0.00) secs
                     EL bad poly no. 405947: BAD Poly: EL = -5.472739e-01 rad. Too low.

  26  FAILED    PSF        primaryMirror.command.revert                                  Sat Mar 21 18:33:55.762 2009  to  Sat Mar 21 18:35:15.568 2009   ( 79.81) secs
                     right PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 18:33:58.245 2009  to  Sat Mar 21 18:35:15.443 2009   ( 77.20) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  28  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 18:33:58.184 2009  to  Sat Mar 21 18:35:15.512 2009   ( 77.33) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  29  FAILED    PMC        mirror.panic                                                  Sat Mar 21 18:35:15.097 2009  to  Sat Mar 21 18:35:15.097 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  30  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 18:50:39.659 2009  to  Sat Mar 21 18:50:39.659 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.close                                             Sat Mar 21 18:50:39.710 2009  to  Sat Mar 21 18:50:39.710 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  32  FAILED    PCS        telescope.telemetryError                                      Sat Mar 21 19:02:35.430 2009  to  Sat Mar 21 19:02:35.430 2009   (  0.00) secs
                     PCS Telescope telemetry error: 2006: MySQL server has gone away

  33  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 19:41:18.635 2009  to  Sat Mar 21 19:41:18.635 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  34  FAILED    PMC        VxInterface.close                                             Sat Mar 21 19:41:18.686 2009  to  Sat Mar 21 19:41:18.686 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  35  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:20:45.214 2009  to  Sat Mar 21 20:20:45.214 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:20:45.162 2009  to  Sat Mar 21 20:20:45.162 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:21:00.759 2009  to  Sat Mar 21 20:21:00.759 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  38  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:21:00.811 2009  to  Sat Mar 21 20:21:00.811 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  39  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:23:21.692 2009  to  Sat Mar 21 20:23:21.692 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:23:21.638 2009  to  Sat Mar 21 20:23:21.638 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  41  FAILED    PCS        guider.telemetryError                                         Sat Mar 21 20:45:18.359 2009  to  Sat Mar 21 20:45:18.359 2009   (  0.00) secs
                     PCS Guider telemetry error: 2006: MySQL server has gone away

  42  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:47:25.504 2009  to  Sat Mar 21 20:47:25.504 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.4964342e-03 1.8435717e-03 -1.7102361e-03 -1.1053658e-01 1.5119171e-01 7.3651969e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:47:25.758 2009  to  Sat Mar 21 20:47:25.758 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.4964342e-03 1.8435717e-03 -1.7102361e-03 -1.1053658e-01 1.5119171e-01 7.3651969e-02

  44  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:49:44.258 2009  to  Sat Mar 21 20:49:44.361 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  45  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:49:44.326 2009  to  Sat Mar 21 20:49:44.422 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  46  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:49:50.390 2009  to  Sat Mar 21 20:49:50.390 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  47  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:49:50.456 2009  to  Sat Mar 21 20:49:50.456 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  48  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:50:46.726 2009  to  Sat Mar 21 20:50:46.726 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0661483e-03 2.2869110e-03 -1.4009476e-03 -1.3487625e-01 1.7007446e-01 8.8093638e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Sat Mar 21 20:50:46.980 2009  to  Sat Mar 21 20:50:46.980 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -1.0661483e-03 2.2869110e-03 -1.4009476e-03 -1.3487625e-01 1.7007446e-01 8.8093638e-02

  50  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 20:51:55.474 2009  to  Sat Mar 21 20:52:02.482 2009   (  7.01) secs
                     IIF SendWavefront command started for left LBC for M1
                     IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for left LBC for M1

  51  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 20:51:55.596 2009  to  Sat Mar 21 20:52:02.309 2009   (  6.71) secs
                     left PSF ApplyZernikes failed

  52  FAILED    PSF        command.setZernikes                                           Sat Mar 21 20:51:55.543 2009  to  Sat Mar 21 20:52:02.365 2009   (  6.82) secs
                     left PSF SetZernikes failed for 28 coefficients to ope M1

  53  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 20:51:55.759 2009  to  Sat Mar 21 20:52:02.253 2009   (  6.49) secs
                     left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 20:51:55.998 2009  to  Sat Mar 21 20:52:02.194 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 20:51:56.062 2009  to  Sat Mar 21 20:52:02.126 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PMC        VxInterface.close                                             Sat Mar 21 20:52:20.242 2009  to  Sat Mar 21 20:52:20.242 2009   (  0.00) secs
                     right PMC Hardpoint closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 20:52:20.190 2009  to  Sat Mar 21 20:52:20.190 2009   (  0.00) secs
                     right PMC Hardpoint length error: expected 304, got 96

  58  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:14:28.188 2009  to  Sat Mar 21 21:14:28.188 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  59  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:14:28.240 2009  to  Sat Mar 21 21:14:28.240 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  60  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:34:49.541 2009  to  Sat Mar 21 21:34:49.541 2009   (  0.00) secs
                     left PMC PMC closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:34:49.489 2009  to  Sat Mar 21 21:34:49.489 2009   (  0.00) secs
                     left PMC PMC length error: expected 32, got 96

  62  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:48:48.576 2009  to  Sat Mar 21 21:48:48.576 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:48:48.628 2009  to  Sat Mar 21 21:48:48.628 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 21:54:53.021 2009  to  Sat Mar 21 21:54:53.021 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        VxInterface.close                                             Sat Mar 21 21:54:53.073 2009  to  Sat Mar 21 21:54:53.073 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:06:31.401 2009  to  Sat Mar 21 22:06:31.401 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:06:31.453 2009  to  Sat Mar 21 22:06:31.453 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  68  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:23:27.947 2009  to  Sat Mar 21 22:23:27.947 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  69  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:23:27.999 2009  to  Sat Mar 21 22:23:27.999 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  70  FAILED    PSF        command.setZernikes                                           Sat Mar 21 22:38:28.960 2009  to  Sat Mar 21 22:38:39.727 2009   ( 10.77) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  71  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 22:38:28.889 2009  to  Sat Mar 21 22:38:39.844 2009   ( 10.96) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  72  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 22:38:29.012 2009  to  Sat Mar 21 22:38:39.671 2009   ( 10.66) secs
                     right PSF ApplyZernikes failed

  73  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 22:38:29.173 2009  to  Sat Mar 21 22:38:39.615 2009   ( 10.44) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  74  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 22:38:32.360 2009  to  Sat Mar 21 22:38:39.559 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  75  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 22:38:32.425 2009  to  Sat Mar 21 22:38:39.489 2009   (  7.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  76  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:41:50.580 2009  to  Sat Mar 21 22:41:50.580 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:41:50.633 2009  to  Sat Mar 21 22:41:50.633 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 22:51:22.493 2009  to  Sat Mar 21 22:51:22.493 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  79  FAILED    PMC        VxInterface.close                                             Sat Mar 21 22:51:22.546 2009  to  Sat Mar 21 22:51:22.546 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  80  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:04:37.473 2009  to  Sat Mar 21 23:04:37.473 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  81  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:04:37.525 2009  to  Sat Mar 21 23:04:37.525 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:09:08.132 2009  to  Sat Mar 21 23:09:08.132 2009   (  0.00) secs
                     left PMC AirPressure length error: expected 100, got 96

  83  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:09:08.184 2009  to  Sat Mar 21 23:09:08.184 2009   (  0.00) secs
                     left PMC AirPressure closing network connection

  84  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:38:33.465 2009  to  Sat Mar 21 23:38:33.465 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  85  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:38:33.517 2009  to  Sat Mar 21 23:38:33.517 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  86  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 23:48:14.677 2009  to  Sat Mar 21 23:48:14.677 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  87  FAILED    PMC        VxInterface.close                                             Sat Mar 21 23:48:14.730 2009  to  Sat Mar 21 23:48:14.730 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  88  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:06:03.716 2009  to  Sun Mar 22 00:06:03.716 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  89  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:06:03.769 2009  to  Sun Mar 22 00:06:03.769 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:07:41.852 2009  to  Sun Mar 22 00:07:41.852 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  91  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:07:41.801 2009  to  Sun Mar 22 00:07:41.801 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  92  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:09:54.481 2009  to  Sun Mar 22 00:09:54.481 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  93  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:09:54.532 2009  to  Sun Mar 22 00:09:54.532 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  94  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:19:18.061 2009  to  Sun Mar 22 00:19:18.061 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  95  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:19:18.010 2009  to  Sun Mar 22 00:19:18.010 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  96  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:47:10.743 2009  to  Sun Mar 22 00:47:10.743 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  97  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:47:10.795 2009  to  Sun Mar 22 00:47:10.795 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  98  FAILED    PMC        VxInterface.close                                             Sun Mar 22 00:51:53.553 2009  to  Sun Mar 22 00:51:53.553 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  99  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 00:51:53.500 2009  to  Sun Mar 22 00:51:53.500 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 100  FAILED    PMC        VxInterface.close                                             Sun Mar 22 01:16:46.742 2009  to  Sun Mar 22 01:16:46.742 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 101  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 22 01:16:46.690 2009  to  Sun Mar 22 01:16:46.690 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 102  FAILED    IIF        command.sendWavefront                                         Sun Mar 22 01:56:50.472 2009  to  Sun Mar 22 01:57:14.424 2009   ( 23.95) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 103  FAILED    PSF        command.setZernikes                                           Sun Mar 22 01:56:50.543 2009  to  Sun Mar 22 01:57:14.305 2009   ( 23.76) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 104  FAILED    PSF        command.applyZernikes                                         Sun Mar 22 01:56:50.596 2009  to  Sun Mar 22 01:57:14.248 2009   ( 23.65) secs
                     right PSF ApplyZernikes failed

 105  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Mar 22 01:56:50.757 2009  to  Sun Mar 22 01:57:14.192 2009   ( 23.43) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 106  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 22 01:56:53.914 2009  to  Sun Mar 22 01:57:14.135 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 107  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 22 01:56:53.976 2009  to  Sun Mar 22 01:57:14.064 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 108  FAILED    PSF        command.setInstrumentOffsets                                  Sun Mar 22 02:48:04.247 2009  to  Sun Mar 22 02:48:10.649 2009   (  6.40) secs
                     right PSF SetInstrumentOffsets failed

 109  FAILED    IIF        command.stepFocus                                             Sun Mar 22 02:48:04.182 2009  to  Sun Mar 22 02:48:10.817 2009   (  6.63) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF StepFocus command failed for right LBC for 0.000000000000000e+00

 110  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Mar 22 02:48:04.300 2009  to  Sun Mar 22 02:48:10.593 2009   (  6.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 111  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 22 02:48:04.412 2009  to  Sun Mar 22 02:48:10.474 2009   (  6.06) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 112  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 22 02:48:04.352 2009  to  Sun Mar 22 02:48:10.538 2009   (  6.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 113  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 22 03:01:06.463 2009  to  Sun Mar 22 03:01:06.463 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.8057823e-03 -2.9885769e-04 1.6062856e-03 -1.5729475e-01 5.0819397e-02 6.2399387e-02

 114  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 22 03:01:06.719 2009  to  Sun Mar 22 03:01:06.719 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.8057823e-03 -2.9885769e-04 1.6062856e-03 -1.5729475e-01 5.0819397e-02 6.2399387e-02

**********************************************************
    Reporting period ending:   Sun Mar 22 06:50:51.094 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback