    TCS Software Performance Report
 
    Observing Night:   Mar 20 2009 to Mar 21 2009
 
    Reporting period beginning:   Fri Mar 20 18:40:48.971 2009
    Reporting period ending:      Sat Mar 21 06:51:56.472 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.MEncoders.earlyStrobe,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.17    0.84    0.72    0.96   100.0 %          2          2                      
                                                                       0.17    0.84    0.72    0.96

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
 *** command.authorize. . . . . . . . . . . . . . . . . . . . . . .    5.75    1.10  -24.87   49.55    98.7 %        223        226                      
                                                                       5.95    1.18  -24.87   49.55
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    1.95    0.48    0.00   24.53    99.7 %        289        290                      
                                                                       1.96    0.49    0.24   24.53
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .   10.62    1.69    0.00   96.39   100.0 %        124        124                      
                                                                      10.71    1.72    0.13   96.39
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .   21.23   10.10    0.00  208.53    97.6 %        287        280          7           
                                                                      21.49   10.14    2.52  208.53
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.91    5.30    3.84    6.82   100.0 %         17         17                      
                                                                       0.91    5.30    3.84    6.82
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    0.92    4.71    3.26    6.27   100.0 %         17         17                      
                                                                       0.92    4.71    3.26    6.27
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   38.82   35.06    0.51  133.16    88.9 %         27         24          3           
                                                                      39.42   39.03    8.15  133.16
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   17.86   13.54    1.05   58.16   100.0 %         25         25                      
                                                                      17.86   13.54    1.05   58.16
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   12.15    7.45    2.07   45.14   100.0 %         24         24                      
                                                                      12.15    7.45    2.07   45.14
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .   13.60   10.04    0.00  106.26    99.4 %        349        349          2           
                                                                      13.39    9.99    0.69  106.26

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             4

IIF Events of Interest

   1  STARTUP   IIF        startup                                                       Fri Mar 20 18:42:25.092 2009  to  Fri Mar 20 18:42:25.092 2009   (  0.00) secs
                     IIF subsystem started

   2  STARTUP   IIF        startup                                                       Fri Mar 20 20:06:00.491 2009  to  Fri Mar 20 20:06:00.491 2009   (  0.00) secs
                     IIF subsystem started

   3  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 21:06:34.208 2009  to  Fri Mar 20 21:06:34.762 2009   (  0.55) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491117122685185e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.511091497144084e+00 El: -2.447831956774970e-01
                     IIF Preset command failed for both LBC mode TRACK from IIF

   4  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 21:11:09.966 2009  to  Fri Mar 20 21:11:10.474 2009   (  0.51) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491117442129629e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.525078554421745e+00 El: -2.565014359979753e-01
                     IIF Preset command failed for both LBC mode TRACK from IIF

   5  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 21:15:43.672 2009  to  Fri Mar 20 21:16:44.859 2009   ( 61.19) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   6  FAILED    IIF        command.moveFocus                                             Fri Mar 20 23:05:19.990 2009  to  Fri Mar 20 23:05:40.650 2009   ( 20.66) secs
                     IIF MoveFocus command started for right LBC for 2.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.000000000000000e-01

   7  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:13:14.981 2009  to  Fri Mar 20 23:13:14.981 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

   8  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:13:47.472 2009  to  Fri Mar 20 23:13:47.472 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

   9  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:23:25.160 2009  to  Fri Mar 20 23:23:30.163 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  10  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:23:28.211 2009  to  Fri Mar 20 23:23:28.211 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  11  SEQERROR  IIF        command.moveFocus                                             Fri Mar 20 23:31:31.059 2009  to  Fri Mar 20 23:36:25.026 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for left LBC for 0.000000000000000e+00

  12  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 23:48:46.060 2009  to  Fri Mar 20 23:48:55.011 2009   (  8.95) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

  13  SEQERROR  IIF        command.authorize                                             Sat Mar 21 00:03:27.656 2009  to  Sat Mar 21 00:03:27.656 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  14  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 00:03:44.972 2009  to  Sat Mar 21 00:15:07.647 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491130216435185e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

  15  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 00:05:33.266 2009  to  Sat Mar 21 00:05:33.266 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491129425925926e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

  16  SEQERROR  IIF        command.moveFocus                                             Sat Mar 21 00:06:27.590 2009  to  Sat Mar 21 00:06:27.590 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for left LBC for -8.000000000000000e-01

  17  FAILED    IIF        command.moveFocus                                             Sat Mar 21 01:15:40.497 2009  to  Sat Mar 21 01:16:00.174 2009   ( 19.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491134422453704e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  18  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:09:07.103 2009  to  Sat Mar 21 03:09:13.744 2009   (  6.64) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 8.000000000000000e-02

  19  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 03:14:15.947 2009  to  Sat Mar 21 03:14:42.729 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491142687500000e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  20  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 03:14:38.758 2009  to  Sat Mar 21 03:14:38.758 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491142656250000e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

  21  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:21.348 2009  to  Sat Mar 21 03:26:26.399 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  22  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:30.441 2009  to  Sat Mar 21 03:26:30.441 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  23  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:38.000 2009  to  Sat Mar 21 03:26:43.003 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  24  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:49.501 2009  to  Sat Mar 21 03:26:16.392 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  25  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:54.460 2009  to  Sat Mar 21 03:26:21.348 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  26  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:57.513 2009  to  Sat Mar 21 03:26:57.513 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  27  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:27:08.555 2009  to  Sat Mar 21 03:27:08.555 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  28  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:27:32.551 2009  to  Sat Mar 21 03:27:32.551 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  29  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 03:29:00.674 2009  to  Sat Mar 21 03:30:12.310 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for left LBC for M1

  30  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:29:21.738 2009  to  Sat Mar 21 03:30:14.425 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Guide command started for right LBC, coord1 1.074205966815659e-06, coord2 6.727076083712780e-07, rotation angle 0.000000000000000e+00

  31  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:29:31.042 2009  to  Sat Mar 21 03:29:31.042 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Guide command complete for right LBC, coord1 3.470147596268452e-07, coord2 2.765438789698833e-07, rotation angle 0.000000000000000e+00

  32  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 03:29:49.665 2009  to  Sat Mar 21 03:29:49.665 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for left LBC for M1

  33  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:32:38.268 2009  to  Sat Mar 21 03:34:43.857 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Guide command started for right LBC, coord1 0.000000000000000e+00, coord2 0.000000000000000e+00, rotation angle 0.000000000000000e+00

  34  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:33:16.036 2009  to  Sat Mar 21 03:33:16.036 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Guide command complete for right LBC, coord1 0.000000000000000e+00, coord2 0.000000000000000e+00, rotation angle 0.000000000000000e+00

  35  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:36:43.735 2009  to  Sat Mar 21 03:36:51.384 2009   (  7.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491144217592593e+04, time 4.350000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

  36  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:44:49.975 2009  to  Sat Mar 21 03:44:50.603 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.000000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.000000000000000e-02

  37  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:52.717 2009  to  Sat Mar 21 03:59:47.716 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  38  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:55.773 2009  to  Sat Mar 21 03:59:55.773 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  39  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:56.766 2009  to  Sat Mar 21 03:59:56.766 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  40  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:00:05.693 2009  to  Sat Mar 21 03:59:52.717 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  41  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:02:34.681 2009  to  Sat Mar 21 04:05:24.859 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491146208333333e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

  42  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:03:35.378 2009  to  Sat Mar 21 04:03:35.378 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491146011574074e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

  43  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:13:07.633 2009  to  Sat Mar 21 04:13:07.633 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for right LBC for M1

  44  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:14:48.040 2009  to  Sat Mar 21 04:15:32.499 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  45  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:11.016 2009  to  Sat Mar 21 04:15:54.080 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  46  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:21.042 2009  to  Sat Mar 21 04:15:48.961 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  47  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:27.520 2009  to  Sat Mar 21 04:15:21.042 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  48  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:37.501 2009  to  Sat Mar 21 04:15:43.980 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

  49  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:52.013 2009  to  Sat Mar 21 04:15:52.013 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  50  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:16:33.647 2009  to  Sat Mar 21 04:16:33.647 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  51  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:16:33.649 2009  to  Sat Mar 21 04:16:33.649 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

  52  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 04:26:47.516 2009  to  Sat Mar 21 04:27:02.494 2009   ( 14.98) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  53  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:35:20.220 2009  to  Sat Mar 21 04:35:20.220 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for right LBC for M1

  54  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:47:24.604 2009  to  Sat Mar 21 04:49:28.039 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for left LBC for M1

  55  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:48:32.434 2009  to  Sat Mar 21 04:48:32.434 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for left LBC for M1

  56  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:50:49.567 2009  to  Sat Mar 21 04:50:49.567 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491149311342592e+04, time 3.900000000000000e+02, interval 1.000000000000000e+00

  57  FAILED    IIF        command.moveFocus                                             Sat Mar 21 05:12:36.443 2009  to  Sat Mar 21 05:12:43.095 2009   (  6.65) secs
                     IIF MoveFocus command started for left LBC for 0.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01

  58  FAILED    IIF        command.moveFocus                                             Sat Mar 21 06:05:41.032 2009  to  Sat Mar 21 06:05:47.673 2009   (  6.64) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3079                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  6151                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    10                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     instrumentCooling.badWeatherData . . . . . . . . . . . . . . .                             2
     hydraulicBearing.badWeatherData. . . . . . . . . . . . . . . .                             2
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                 16           
     hydraulicBearing.badPMCData. . . . . . . . . . . . . . . . . .                 16           
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     170                      

ECS Events of Interest

   1  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:06:51.202 2009  to  Fri Mar 20 20:06:51.202 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   2  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:06:51.150 2009  to  Fri Mar 20 20:06:51.150 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   3  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:01.293 2009  to  Fri Mar 20 20:07:01.293 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   4  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:01.346 2009  to  Fri Mar 20 20:07:01.346 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   5  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:11.491 2009  to  Fri Mar 20 20:07:11.491 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:11.439 2009  to  Fri Mar 20 20:07:11.439 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:21.581 2009  to  Fri Mar 20 20:07:21.581 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

   8  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:21.633 2009  to  Fri Mar 20 20:07:21.633 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

   9  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:31.726 2009  to  Fri Mar 20 20:07:31.726 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  10  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:31.778 2009  to  Fri Mar 20 20:07:31.778 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  11  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:41.905 2009  to  Fri Mar 20 20:07:41.905 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  12  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:41.869 2009  to  Fri Mar 20 20:07:41.869 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  13  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:51.997 2009  to  Fri Mar 20 20:07:51.997 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  14  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:52.050 2009  to  Fri Mar 20 20:07:52.050 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:02.132 2009  to  Fri Mar 20 20:08:02.132 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:02.185 2009  to  Fri Mar 20 20:08:02.185 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  17  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:12.328 2009  to  Fri Mar 20 20:08:12.328 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  18  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:12.276 2009  to  Fri Mar 20 20:08:12.276 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  19  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:22.420 2009  to  Fri Mar 20 20:08:22.420 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  20  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:22.472 2009  to  Fri Mar 20 20:08:22.472 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  21  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:32.564 2009  to  Fri Mar 20 20:08:32.564 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  22  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:32.616 2009  to  Fri Mar 20 20:08:32.616 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  23  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:06.411 2009  to  Fri Mar 20 20:09:06.411 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  24  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:06.359 2009  to  Fri Mar 20 20:09:06.359 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  25  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:16.498 2009  to  Fri Mar 20 20:09:16.498 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  26  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:16.551 2009  to  Fri Mar 20 20:09:16.551 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  27  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:26.693 2009  to  Fri Mar 20 20:09:26.693 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  28  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:26.745 2009  to  Fri Mar 20 20:09:26.745 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  29  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:36.837 2009  to  Fri Mar 20 20:09:36.837 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  30  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:36.889 2009  to  Fri Mar 20 20:09:36.889 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  31  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:47.032 2009  to  Fri Mar 20 20:09:47.032 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  32  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:46.980 2009  to  Fri Mar 20 20:09:46.980 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      22                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       8                      

LSS Events of Interest

   1  STARTUP   LSS        startup                                                       Fri Mar 20 18:40:48.971 2009  to  Fri Mar 20 18:40:48.971 2009   (  0.00) secs
                     The LSS was started.

   2  STARTUP   LSS        startup                                                       Fri Mar 20 20:05:49.736 2009  to  Fri Mar 20 20:05:49.736 2009   (  0.00) secs
                     The LSS was started.
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      22                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      92                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           125
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      14                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      30                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            21
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            13
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     112                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       1                      
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                229           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       6                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      13                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                            10
     MCSPU.ELDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             1
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.MEncoders.earlyStrobe. . . . . . . . . . . . . . . . . .       6                     1
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             7
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.setVel . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.amplifierFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      54                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     112                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     306                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     102                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 20 19:01:53.530 2009  to  Fri Mar 20 19:01:53.530 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 20 19:01:53.536 2009  to  Fri Mar 20 19:01:53.536 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Mar 20 19:01:53.626 2009  to  Fri Mar 20 19:01:53.626 2009   (  0.00) secs
                     drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.648 2009  to  Fri Mar 20 19:01:54.648 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.650 2009  to  Fri Mar 20 19:01:54.650 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.650 2009  to  Fri Mar 20 19:01:54.650 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.651 2009  to  Fri Mar 20 19:01:54.651 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.651 2009  to  Fri Mar 20 19:01:54.651 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:01:56.552 2009  to  Fri Mar 20 19:01:56.552 2009   (  0.00) secs
                     EL bad poly no. 55: BAD Poly: EL = -1.053768e+00 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:01:59.602 2009  to  Fri Mar 20 19:01:59.602 2009   (  0.00) secs
                     EL bad poly no. 116: BAD Poly: EL = -1.053616e+00 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:02.603 2009  to  Fri Mar 20 19:02:02.603 2009   (  0.00) secs
                     EL bad poly no. 176: BAD Poly: EL = -1.053467e+00 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:05.607 2009  to  Fri Mar 20 19:02:05.607 2009   (  0.00) secs
                     EL bad poly no. 236: BAD Poly: EL = -1.053317e+00 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:08.653 2009  to  Fri Mar 20 19:02:08.653 2009   (  0.00) secs
                     EL bad poly no. 297: BAD Poly: EL = -1.053166e+00 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:11.657 2009  to  Fri Mar 20 19:02:11.657 2009   (  0.00) secs
                     EL bad poly no. 357: BAD Poly: EL = -1.053017e+00 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:14.709 2009  to  Fri Mar 20 19:02:14.709 2009   (  0.00) secs
                     EL bad poly no. 418: BAD Poly: EL = -1.052865e+00 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:17.767 2009  to  Fri Mar 20 19:02:17.767 2009   (  0.00) secs
                     EL bad poly no. 479: BAD Poly: EL = -1.052712e+00 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:20.820 2009  to  Fri Mar 20 19:02:20.820 2009   (  0.00) secs
                     EL bad poly no. 539: BAD Poly: EL = -1.052561e+00 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:23.849 2009  to  Fri Mar 20 19:02:23.849 2009   (  0.00) secs
                     EL bad poly no. 596: BAD Poly: EL = -1.052410e+00 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:26.868 2009  to  Fri Mar 20 19:02:26.868 2009   (  0.00) secs
                     EL bad poly no. 651: BAD Poly: EL = -1.052259e+00 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:29.889 2009  to  Fri Mar 20 19:02:29.889 2009   (  0.00) secs
                     EL bad poly no. 706: BAD Poly: EL = -1.052109e+00 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:32.915 2009  to  Fri Mar 20 19:02:32.915 2009   (  0.00) secs
                     EL bad poly no. 762: BAD Poly: EL = -1.051958e+00 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:35.937 2009  to  Fri Mar 20 19:02:35.937 2009   (  0.00) secs
                     EL bad poly no. 816: BAD Poly: EL = -1.051807e+00 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:38.948 2009  to  Fri Mar 20 19:02:38.948 2009   (  0.00) secs
                     EL bad poly no. 871: BAD Poly: EL = -1.051657e+00 rad. Too low.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:42.016 2009  to  Fri Mar 20 19:02:42.016 2009   (  0.00) secs
                     EL bad poly no. 926: BAD Poly: EL = -1.051504e+00 rad. Too low.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:45.040 2009  to  Fri Mar 20 19:02:45.040 2009   (  0.00) secs
                     EL bad poly no. 981: BAD Poly: EL = -1.051354e+00 rad. Too low.

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:48.092 2009  to  Fri Mar 20 19:02:48.092 2009   (  0.00) secs
                     EL bad poly no. 1036: BAD Poly: EL = -1.051201e+00 rad. Too low.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:51.117 2009  to  Fri Mar 20 19:02:51.117 2009   (  0.00) secs
                     EL bad poly no. 1091: BAD Poly: EL = -1.051050e+00 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:54.176 2009  to  Fri Mar 20 19:02:54.176 2009   (  0.00) secs
                     EL bad poly no. 1147: BAD Poly: EL = -1.050898e+00 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:57.226 2009  to  Fri Mar 20 19:02:57.226 2009   (  0.00) secs
                     EL bad poly no. 1202: BAD Poly: EL = -1.050746e+00 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:00.265 2009  to  Fri Mar 20 19:03:00.265 2009   (  0.00) secs
                     EL bad poly no. 1257: BAD Poly: EL = -1.050594e+00 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:03.264 2009  to  Fri Mar 20 19:03:03.264 2009   (  0.00) secs
                     EL bad poly no. 1311: BAD Poly: EL = -1.050444e+00 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:06.270 2009  to  Fri Mar 20 19:03:06.270 2009   (  0.00) secs
                     EL bad poly no. 1366: BAD Poly: EL = -1.050294e+00 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:09.270 2009  to  Fri Mar 20 19:03:09.270 2009   (  0.00) secs
                     EL bad poly no. 1421: BAD Poly: EL = -1.050144e+00 rad. Too low.

  37  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Mar 20 19:10:35.433 2009  to  Fri Mar 20 19:10:35.433 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  38  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Mar 20 19:10:35.621 2009  to  Fri Mar 20 19:10:35.621 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Mar 20 19:10:35.623 2009  to  Fri Mar 20 19:10:35.623 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:10:51.113 2009  to  Fri Mar 20 20:10:51.113 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  41  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:13:33.026 2009  to  Fri Mar 20 20:13:33.026 2009   (  0.00) secs
                    

  42  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:16:23.462 2009  to  Fri Mar 20 20:16:23.462 2009   (  0.00) secs
                    

  43  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:20:08.821 2009  to  Fri Mar 20 20:20:08.821 2009   (  0.00) secs
                    

  44  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:20:08.844 2009  to  Fri Mar 20 20:20:08.844 2009   (  0.00) secs
                    

  45  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:21:42.347 2009  to  Fri Mar 20 20:21:42.347 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  46  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:21:46.350 2009  to  Fri Mar 20 20:21:46.350 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  47  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Fri Mar 20 20:21:46.460 2009  to  Fri Mar 20 20:21:46.460 2009   (  0.00) secs
                     EL:FL pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  48  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:22:59.560 2009  to  Fri Mar 20 20:22:59.560 2009   (  0.00) secs
                    

  49  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:22:59.583 2009  to  Fri Mar 20 20:22:59.583 2009   (  0.00) secs
                    
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             1

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Fri Mar 20 20:08:27.261 2009  to  Fri Mar 20 20:08:27.261 2009   (  0.00) secs
                     The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    2.09    0.37    0.04   21.05   100.0 %        124        124                      
                                                                       2.09    0.37    0.04   21.05
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    1.25    0.20    0.00   21.40   100.0 %        289        289                      
                                                                       1.26    0.20    0.10   21.40
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    2.60    1.21    0.04    5.87   100.0 %          5          5                      
                                                                       2.60    1.21    0.04    5.87
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.08    0.24    0.06    0.37   100.0 %         17         17                      
                                                                       0.08    0.24    0.06    0.37
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.06    0.11    0.05    0.25    93.1 %         29         27          2           
                                                                       0.06    0.11    0.06    0.25
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.46    0.46    0.46   100.0 %          1          1                      
                                                                       0.00    0.46    0.46    0.46
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.19    0.60    0.31    0.83   100.0 %         27         27                      
                                                                       0.19    0.60    0.31    0.83
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.07    0.05    0.00    0.10     0.0 %          2                     2           
                                                                       0.00    0.10    0.10    0.10

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Fri Mar 20 20:08:13.989 2009  to  Fri Mar 20 20:08:13.989 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   2  SEQERROR  PCS        telescope.command.stopTracking                                Fri Mar 20 20:59:35.826 2009  to  Fri Mar 20 20:59:35.830 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   3  SEQERROR  PCS        telescope.command.stopTracking                                Fri Mar 20 20:59:35.962 2009  to  Fri Mar 20 20:59:35.962 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   4  FAILED    PCS        telescope.command.setEquatorialTarget                         Fri Mar 20 21:06:34.586 2009  to  Fri Mar 20 21:06:34.639 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 RotMode: IDLE Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.511091497144084e+00 El: -2.447831956774970e-01

   5  FAILED    PCS        telescope.command.setEquatorialTarget                         Fri Mar 20 21:11:10.299 2009  to  Fri Mar 20 21:11:10.354 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 RotMode: IDLE Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.525078554421745e+00 El: -2.565014359979753e-01

   6  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 00:05:18.006 2009  to  Sat Mar 21 00:15:07.708 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

   7  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 00:05:30.189 2009  to  Sat Mar 21 00:05:30.189 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

   8  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 03:14:16.009 2009  to  Sat Mar 21 03:22:21.256 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

   9  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 03:14:19.160 2009  to  Sat Mar 21 03:14:19.160 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

  10  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:02:46.129 2009  to  Sat Mar 21 04:05:24.920 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

  11  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:02:49.240 2009  to  Sat Mar 21 04:02:49.240 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

  12  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:50:16.593 2009  to  Sat Mar 21 04:52:18.279 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

  13  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:50:39.793 2009  to  Sat Mar 21 04:50:39.793 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          1          1                      
                                                                       0.00    1.05    1.05    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.11    2.65    2.04   11.05   100.0 %        193        193                      
                                                                       1.11    2.65    2.04   11.05
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.23    2.56    2.06    5.06   100.0 %          6          6                      
                                                                       1.23    2.56    2.06    5.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.00    5.06    5.06    5.06   100.0 %          1          1                      
                                                                       0.00    5.06    5.06    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.17   66.17   66.17   100.0 %          1          1                      
                                                                       0.00   66.17   66.17   66.17
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   10.86    7.39    0.00  205.07    98.5 %        670        658         10           
                                                                      10.93    7.38    2.05  205.07
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  231.65  231.65  231.65   100.0 %          1          1                      
                                                                       0.00  231.65  231.65  231.65
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.11    0.11    0.11   100.0 %          1          1                      
                                                                       0.00    0.11    0.11    0.11
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.86    0.31    0.05    3.05   100.0 %         12         12                      
                                                                       0.86    0.31    0.05    3.05

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                           658
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      42                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       2                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       2                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       2                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            12
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      15                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      12                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             9
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             6
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       6                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            32
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     193                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 22           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 22           
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           185
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             9
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             1
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  1           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        actuator.telemetryError                                       Fri Mar 20 20:08:45.287 2009  to  Fri Mar 20 20:08:45.287 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   2  STARTUP   PMC        startup                                                       Fri Mar 20 20:08:48.422 2009  to  Fri Mar 20 20:08:48.422 2009   (  0.00) secs
                     left PMC subsystem started, version 4.7

   3  FAILED    PMC        actuator.telemetryError                                       Fri Mar 20 20:08:57.620 2009  to  Fri Mar 20 20:08:57.620 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   4  STARTUP   PMC        startup                                                       Fri Mar 20 20:09:01.451 2009  to  Fri Mar 20 20:09:01.451 2009   (  0.00) secs
                     right PMC subsystem started, version 4.7

   5  FAILED    PMC        VxInterface.close                                             Fri Mar 20 20:47:55.856 2009  to  Fri Mar 20 20:47:55.856 2009   (  0.00) secs
                     left PMC Mirror closing network connection

   6  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 20:47:55.804 2009  to  Fri Mar 20 20:47:55.804 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 21:16:29.437 2009  to  Fri Mar 20 21:16:44.517 2009   ( 15.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PMC        VxInterface.close                                             Fri Mar 20 21:33:34.039 2009  to  Fri Mar 20 21:33:34.039 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   9  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 21:33:33.986 2009  to  Fri Mar 20 21:33:33.986 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:05:20.220 2009  to  Fri Mar 20 23:05:40.310 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:09:51.013 2009  to  Fri Mar 20 23:09:51.013 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:09:51.065 2009  to  Fri Mar 20 23:09:51.065 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:12:07.342 2009  to  Fri Mar 20 23:12:07.342 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:12:07.287 2009  to  Fri Mar 20 23:12:07.287 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:24:05.835 2009  to  Fri Mar 20 23:24:05.835 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:24:05.783 2009  to  Fri Mar 20 23:24:05.783 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:25:57.161 2009  to  Fri Mar 20 23:26:52.997 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

  18  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:26:11.240 2009  to  Fri Mar 20 23:26:11.240 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  19  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:27:59.948 2009  to  Fri Mar 20 23:27:59.948 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  20  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:28:00.005 2009  to  Fri Mar 20 23:28:00.005 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  21  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:29:17.333 2009  to  Fri Mar 20 23:29:17.333 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  22  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:29:35.534 2009  to  Fri Mar 20 23:28:58.272 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  23  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:31:31.302 2009  to  Fri Mar 20 23:34:43.332 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

  24  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:39:17.845 2009  to  Fri Mar 20 23:39:17.845 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:39:17.945 2009  to  Fri Mar 20 23:39:17.945 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  26  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:48:48.738 2009  to  Fri Mar 20 23:48:54.802 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:00:48.696 2009  to  Sat Mar 21 00:00:48.696 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:00:48.644 2009  to  Sat Mar 21 00:00:48.644 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:21:12.115 2009  to  Sat Mar 21 00:21:12.115 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:21:12.063 2009  to  Sat Mar 21 00:21:12.063 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:30:02.431 2009  to  Sat Mar 21 00:30:02.431 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:30:02.378 2009  to  Sat Mar 21 00:30:02.378 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:37:32.665 2009  to  Sat Mar 21 00:37:32.665 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:37:32.614 2009  to  Sat Mar 21 00:37:32.614 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:45:08.945 2009  to  Sat Mar 21 00:45:08.945 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  36  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:45:08.997 2009  to  Sat Mar 21 00:45:08.997 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  37  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 01:15:40.729 2009  to  Sat Mar 21 01:15:59.820 2009   ( 19.09) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 01:41:59.825 2009  to  Sat Mar 21 01:41:59.825 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Sat Mar 21 01:41:59.876 2009  to  Sat Mar 21 01:41:59.876 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 02:51:25.196 2009  to  Sat Mar 21 02:51:25.196 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.close                                             Sat Mar 21 02:51:25.248 2009  to  Sat Mar 21 02:51:25.248 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  42  FAILED    PMC        VxInterface.close                                             Sat Mar 21 02:53:54.926 2009  to  Sat Mar 21 02:53:54.926 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 02:53:54.873 2009  to  Sat Mar 21 02:53:54.873 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  44  FAILED    PMC        VxInterface.close                                             Sat Mar 21 03:01:53.054 2009  to  Sat Mar 21 03:01:53.054 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 03:01:53.002 2009  to  Sat Mar 21 03:01:53.002 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  46  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:09:07.332 2009  to  Sat Mar 21 03:09:13.397 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  47  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:32:08.931 2009  to  Sat Mar 21 03:33:54.924 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

  48  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:36:43.971 2009  to  Sat Mar 21 03:36:51.039 2009   (  7.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PMC        mirror.panic                                                  Sat Mar 21 03:44:09.801 2009  to  Sat Mar 21 03:44:09.801 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:44:50.204 2009  to  Sat Mar 21 03:44:50.257 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  51  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 04:26:51.071 2009  to  Sat Mar 21 04:27:02.144 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PMC        VxInterface.close                                             Sat Mar 21 04:32:46.632 2009  to  Sat Mar 21 04:32:46.632 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  53  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 04:32:46.581 2009  to  Sat Mar 21 04:32:46.581 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  54  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 04:54:57.074 2009  to  Sat Mar 21 04:54:57.074 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Sat Mar 21 04:54:57.126 2009  to  Sat Mar 21 04:54:57.126 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  56  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 05:12:36.681 2009  to  Sat Mar 21 05:12:42.748 2009   (  6.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  57  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:15:12.941 2009  to  Sat Mar 21 05:15:12.941 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:15:12.889 2009  to  Sat Mar 21 05:15:12.889 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  59  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:21:43.040 2009  to  Sat Mar 21 05:21:43.040 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:21:43.091 2009  to  Sat Mar 21 05:21:43.091 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  61  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:27:20.332 2009  to  Sat Mar 21 05:27:20.332 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:27:20.279 2009  to  Sat Mar 21 05:27:20.279 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 06:02:18.561 2009  to  Sat Mar 21 06:02:18.561 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Sat Mar 21 06:02:18.614 2009  to  Sat Mar 21 06:02:18.614 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  65  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 06:05:41.262 2009  to  Sat Mar 21 06:05:47.330 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .   12.87    9.63    0.00   99.74    99.4 %        350        347          2           
                                                                      12.62    9.52    0.45   99.74
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.05    0.09   100.0 %         54         54                      
                                                                       0.01    0.05    0.05    0.09
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .   13.14    7.94    0.00  205.42    97.5 %        285        281          7           
                                                                      13.30    7.99    2.40  205.42
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          2          2                      
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .   12.54    9.59    0.00   99.85    99.4 %        349        349          2           
                                                                      12.30    9.54    0.56   99.85
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .   10.87    8.71    0.00   99.52    99.4 %        354        351          2           
                                                                      10.55    8.62    0.24   99.52
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    9.60    7.59    0.00  108.18    98.5 %        670        659         10           
                                                                       9.65    7.59    2.18  108.18
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.20    3.14    2.18    5.19   100.0 %          6          6                      
                                                                       1.20    3.14    2.18    5.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    1.07    0.19    0.00   18.53   100.0 %        348        348                      
                                                                       1.08    0.19    0.07   18.53
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.19    0.23    0.06    0.42   100.0 %          6          6                      
                                                                       0.19    0.23    0.06    0.42
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.40    1.64    1.26    2.05   100.0 %          3          3                      
                                                                       0.40    1.64    1.26    2.05
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    4.43   53.87   49.62   58.46   100.0 %          3          3                      
                                                                       4.43   53.87   49.62   58.46
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   14.16   21.33   11.31   31.35   100.0 %          2          2                      
                                                                      14.16   21.33   11.31   31.35
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .   14.19    7.96    0.00  205.31    97.6 %        286        280          7           
                                                                      14.36    7.98    2.29  205.31
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.07   100.0 %          6          6                      
                                                                       0.00    0.06    0.06    0.07
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    2.43    0.22    0.00   45.04   100.0 %        356        356                      
                                                                       2.44    0.22    0.05   45.04
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.19    1.33    1.15    1.52   100.0 %          3          3                      
                                                                       0.19    1.33    1.15    1.52
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.04    0.82    0.77    0.85   100.0 %          3          3                      
                                                                       0.04    0.82    0.77    0.85
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.02    0.10    0.08    0.12   100.0 %          3          3                      
                                                                       0.02    0.10    0.08    0.12
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.17    0.64    0.51    0.83   100.0 %          3          3                      
                                                                       0.17    0.64    0.51    0.83

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               6586           

PSF Events of Interest

   1  STARTUP   PSF        startup                                                       Fri Mar 20 18:44:48.250 2009  to  Fri Mar 20 18:44:48.250 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

   2  STARTUP   PSF        startup                                                       Fri Mar 20 20:09:08.497 2009  to  Fri Mar 20 20:09:08.497 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

   3  STARTUP   PSF        startup                                                       Fri Mar 20 20:09:17.160 2009  to  Fri Mar 20 20:09:17.160 2009   (  0.00) secs
                     right PSF subsystem started, version 4.32

   4  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 21:15:43.797 2009  to  Fri Mar 20 21:16:44.690 2009   ( 60.89) secs
                     right PSF ApplyZernikes failed

   5  FAILED    PSF        command.setZernikes                                           Fri Mar 20 21:15:43.744 2009  to  Fri Mar 20 21:16:44.745 2009   ( 61.00) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

   6  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 21:15:43.960 2009  to  Fri Mar 20 21:16:44.635 2009   ( 60.68) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 21:16:29.379 2009  to  Fri Mar 20 21:16:44.580 2009   ( 15.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:38.337 2009  to  Fri Mar 20 21:56:38.337 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:38.593 2009  to  Fri Mar 20 21:56:38.593 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:39.859 2009  to  Fri Mar 20 21:56:39.859 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  11  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.114 2009  to  Fri Mar 20 21:56:40.114 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  12  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.369 2009  to  Fri Mar 20 21:56:40.369 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  13  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.624 2009  to  Fri Mar 20 21:56:40.624 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  14  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:42.295 2009  to  Fri Mar 20 21:56:42.295 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:42.550 2009  to  Fri Mar 20 21:56:42.550 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:43.412 2009  to  Fri Mar 20 21:56:43.412 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:50.142 2009  to  Fri Mar 20 21:56:50.142 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  18  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:58.494 2009  to  Fri Mar 20 21:56:58.494 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:03.204 2009  to  Fri Mar 20 21:57:03.204 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:03.459 2009  to  Fri Mar 20 21:57:03.459 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:04.523 2009  to  Fri Mar 20 21:57:04.523 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:04.777 2009  to  Fri Mar 20 21:57:04.777 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.032 2009  to  Fri Mar 20 21:57:05.032 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.490 2009  to  Fri Mar 20 21:57:05.490 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.746 2009  to  Fri Mar 20 21:57:05.746 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:06.002 2009  to  Fri Mar 20 21:57:06.002 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:09.088 2009  to  Fri Mar 20 21:57:09.088 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

  28  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:10.977 2009  to  Fri Mar 20 21:57:10.977 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:11.232 2009  to  Fri Mar 20 21:57:11.232 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:11.892 2009  to  Fri Mar 20 21:57:11.892 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:12.147 2009  to  Fri Mar 20 21:57:12.147 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:13.414 2009  to  Fri Mar 20 21:57:13.414 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

  33  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 23:05:20.053 2009  to  Fri Mar 20 23:05:40.483 2009   ( 20.43) secs
                     right PSF SetInstrumentOffsets failed

  34  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 23:05:20.105 2009  to  Fri Mar 20 23:05:40.428 2009   ( 20.32) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:05:20.157 2009  to  Fri Mar 20 23:05:40.373 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  36  SEQERROR  PSF        primaryMirror.command.setZernikes                             Fri Mar 20 23:13:55.006 2009  to  Fri Mar 20 23:14:55.279 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror getting Zernike coefficients

  37  SEQERROR  PSF        primaryMirror.command.setZernikes                             Fri Mar 20 23:14:03.243 2009  to  Fri Mar 20 23:14:03.243 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror Zernike coefficients received

  38  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Fri Mar 20 23:16:38.483 2009  to  Fri Mar 20 23:19:34.661 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror initForceCalc started

  39  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Fri Mar 20 23:16:38.599 2009  to  Fri Mar 20 23:16:38.599 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror initForceCalc complete for 12 modes, FCin flag 0

  40  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:25:40.040 2009  to  Fri Mar 20 23:26:52.934 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  41  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:26:20.301 2009  to  Fri Mar 20 23:26:20.301 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  42  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:28:49.201 2009  to  Fri Mar 20 23:31:20.812 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:29:29.012 2009  to  Fri Mar 20 23:29:29.012 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  44  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:48:48.674 2009  to  Fri Mar 20 23:48:54.888 2009   (  6.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  45  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 23:48:56.295 2009  to  Fri Mar 20 23:55:09.066 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror setLocalOffsets started

  46  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:52:21.547 2009  to  Fri Mar 20 23:52:21.547 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  47  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 00:06:27.469 2009  to  Sat Mar 21 00:06:27.469 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror setLocalOffsets complete

  48  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 00:06:27.525 2009  to  Sat Mar 21 00:06:27.525 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetInstrumentOffsets complete

  49  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 01:15:40.561 2009  to  Sat Mar 21 01:16:00.004 2009   ( 19.44) secs
                     right PSF SetInstrumentOffsets failed

  50  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 01:15:40.613 2009  to  Sat Mar 21 01:15:59.947 2009   ( 19.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 01:15:40.666 2009  to  Sat Mar 21 01:15:59.889 2009   ( 19.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:09:07.167 2009  to  Sat Mar 21 03:09:13.576 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  53  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:09:07.219 2009  to  Sat Mar 21 03:09:13.520 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:09:07.271 2009  to  Sat Mar 21 03:09:13.464 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:13:55.298 2009  to  Sat Mar 21 03:15:36.852 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  56  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:14:41.904 2009  to  Sat Mar 21 03:14:41.904 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

  57  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:17:15.532 2009  to  Sat Mar 21 03:22:05.667 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

  58  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:18:11.408 2009  to  Sat Mar 21 03:18:11.408 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF ApplyZernikes complete

  59  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 03:29:00.744 2009  to  Sat Mar 21 03:30:15.972 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF SetZernikes started for 28 coefficients to ope M1

  60  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:29:00.796 2009  to  Sat Mar 21 03:30:16.025 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

  61  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:29:00.956 2009  to  Sat Mar 21 03:30:16.189 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  62  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 03:29:04.609 2009  to  Sat Mar 21 03:29:04.609 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetZernikes complete for 28 coefficient to ope M1

  63  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:32:08.868 2009  to  Sat Mar 21 03:33:54.858 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  64  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:34:56.613 2009  to  Sat Mar 21 03:37:37.659 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

  65  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:34:56.774 2009  to  Sat Mar 21 03:37:37.822 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:34:57.015 2009  to  Sat Mar 21 03:36:43.918 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:36:43.797 2009  to  Sat Mar 21 03:36:51.216 2009   (  7.42) secs
                     right PSF SetInstrumentOffsets failed

  68  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:36:43.850 2009  to  Sat Mar 21 03:36:51.159 2009   (  7.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  69  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:36:43.903 2009  to  Sat Mar 21 03:36:51.103 2009   (  7.20) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  70  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:44:50.038 2009  to  Sat Mar 21 03:44:50.436 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

  71  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:44:50.091 2009  to  Sat Mar 21 03:44:50.380 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  72  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:44:50.144 2009  to  Sat Mar 21 03:44:50.324 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  73  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 04:04:06.729 2009  to  Sat Mar 21 04:04:06.729 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror setLocalOffsets complete

  74  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 04:04:06.784 2009  to  Sat Mar 21 04:04:06.784 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetInstrumentOffsets complete

  75  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 04:04:09.839 2009  to  Sat Mar 21 04:04:09.839 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete

  76  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Sat Mar 21 04:11:58.061 2009  to  Sat Mar 21 04:11:58.061 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror initForceCalc complete for 2 modes, FCin flag 0

  77  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Sat Mar 21 04:12:01.190 2009  to  Sat Mar 21 04:26:48.063 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror initForceCalc started

  78  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:13:07.458 2009  to  Sat Mar 21 04:13:07.458 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

  79  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 04:13:07.514 2009  to  Sat Mar 21 04:13:07.514 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF ApplyZernikes complete

  80  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:13:07.570 2009  to  Sat Mar 21 04:13:07.570 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetZernikes complete for 28 coefficient to ope M1

  81  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 04:26:47.638 2009  to  Sat Mar 21 04:27:02.322 2009   ( 14.68) secs
                     right PSF ApplyZernikes failed

  82  FAILED    PSF        command.setZernikes                                           Sat Mar 21 04:26:47.585 2009  to  Sat Mar 21 04:27:02.378 2009   ( 14.79) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  83  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:26:47.870 2009  to  Sat Mar 21 04:27:02.266 2009   ( 14.40) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 04:26:51.009 2009  to  Sat Mar 21 04:27:02.210 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:35:20.157 2009  to  Sat Mar 21 04:35:20.157 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetZernikes complete for 28 coefficient to ope M1

  86  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:37:01.031 2009  to  Sat Mar 21 04:38:28.265 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

  87  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:38:02.457 2009  to  Sat Mar 21 04:38:02.457 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

  88  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:47:48.234 2009  to  Sat Mar 21 04:49:28.106 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF SetZernikes started for 28 coefficients to ope M1

  89  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:48:32.368 2009  to  Sat Mar 21 04:48:32.368 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetZernikes complete for 28 coefficient to ope M1

  90  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 05:12:36.509 2009  to  Sat Mar 21 05:12:42.925 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

  91  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 05:12:36.615 2009  to  Sat Mar 21 05:12:42.815 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  92  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 05:12:36.562 2009  to  Sat Mar 21 05:12:42.870 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  93  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 06:05:41.097 2009  to  Sat Mar 21 06:05:47.505 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  94  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 06:05:41.150 2009  to  Sat Mar 21 06:05:47.449 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  95  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 06:05:41.201 2009  to  Sat Mar 21 06:05:47.394 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  STARTUP   LSS        startup                                                       Fri Mar 20 18:40:48.971 2009  to  Fri Mar 20 18:40:48.971 2009   (  0.00) secs
                     The LSS was started.

   2  STARTUP   IIF        startup                                                       Fri Mar 20 18:42:25.092 2009  to  Fri Mar 20 18:42:25.092 2009   (  0.00) secs
                     IIF subsystem started

   3  STARTUP   PSF        startup                                                       Fri Mar 20 18:44:48.250 2009  to  Fri Mar 20 18:44:48.250 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 20 19:01:53.530 2009  to  Fri Mar 20 19:01:53.530 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Mar 20 19:01:53.536 2009  to  Fri Mar 20 19:01:53.536 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Mar 20 19:01:53.626 2009  to  Fri Mar 20 19:01:53.626 2009   (  0.00) secs
                     drive cabinet has turned on.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.648 2009  to  Fri Mar 20 19:01:54.648 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.649 2009  to  Fri Mar 20 19:01:54.649 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.650 2009  to  Fri Mar 20 19:01:54.650 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.650 2009  to  Fri Mar 20 19:01:54.650 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.651 2009  to  Fri Mar 20 19:01:54.651 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Mar 20 19:01:54.651 2009  to  Fri Mar 20 19:01:54.651 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:01:56.552 2009  to  Fri Mar 20 19:01:56.552 2009   (  0.00) secs
                     EL bad poly no. 55: BAD Poly: EL = -1.053768e+00 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:01:59.602 2009  to  Fri Mar 20 19:01:59.602 2009   (  0.00) secs
                     EL bad poly no. 116: BAD Poly: EL = -1.053616e+00 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:02.603 2009  to  Fri Mar 20 19:02:02.603 2009   (  0.00) secs
                     EL bad poly no. 176: BAD Poly: EL = -1.053467e+00 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:05.607 2009  to  Fri Mar 20 19:02:05.607 2009   (  0.00) secs
                     EL bad poly no. 236: BAD Poly: EL = -1.053317e+00 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:08.653 2009  to  Fri Mar 20 19:02:08.653 2009   (  0.00) secs
                     EL bad poly no. 297: BAD Poly: EL = -1.053166e+00 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:11.657 2009  to  Fri Mar 20 19:02:11.657 2009   (  0.00) secs
                     EL bad poly no. 357: BAD Poly: EL = -1.053017e+00 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:14.709 2009  to  Fri Mar 20 19:02:14.709 2009   (  0.00) secs
                     EL bad poly no. 418: BAD Poly: EL = -1.052865e+00 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:17.767 2009  to  Fri Mar 20 19:02:17.767 2009   (  0.00) secs
                     EL bad poly no. 479: BAD Poly: EL = -1.052712e+00 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:20.820 2009  to  Fri Mar 20 19:02:20.820 2009   (  0.00) secs
                     EL bad poly no. 539: BAD Poly: EL = -1.052561e+00 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:23.849 2009  to  Fri Mar 20 19:02:23.849 2009   (  0.00) secs
                     EL bad poly no. 596: BAD Poly: EL = -1.052410e+00 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:26.868 2009  to  Fri Mar 20 19:02:26.868 2009   (  0.00) secs
                     EL bad poly no. 651: BAD Poly: EL = -1.052259e+00 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:29.889 2009  to  Fri Mar 20 19:02:29.889 2009   (  0.00) secs
                     EL bad poly no. 706: BAD Poly: EL = -1.052109e+00 rad. Too low.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:32.915 2009  to  Fri Mar 20 19:02:32.915 2009   (  0.00) secs
                     EL bad poly no. 762: BAD Poly: EL = -1.051958e+00 rad. Too low.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:35.937 2009  to  Fri Mar 20 19:02:35.937 2009   (  0.00) secs
                     EL bad poly no. 816: BAD Poly: EL = -1.051807e+00 rad. Too low.

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:38.948 2009  to  Fri Mar 20 19:02:38.948 2009   (  0.00) secs
                     EL bad poly no. 871: BAD Poly: EL = -1.051657e+00 rad. Too low.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:42.016 2009  to  Fri Mar 20 19:02:42.016 2009   (  0.00) secs
                     EL bad poly no. 926: BAD Poly: EL = -1.051504e+00 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:45.040 2009  to  Fri Mar 20 19:02:45.040 2009   (  0.00) secs
                     EL bad poly no. 981: BAD Poly: EL = -1.051354e+00 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:48.092 2009  to  Fri Mar 20 19:02:48.092 2009   (  0.00) secs
                     EL bad poly no. 1036: BAD Poly: EL = -1.051201e+00 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:51.117 2009  to  Fri Mar 20 19:02:51.117 2009   (  0.00) secs
                     EL bad poly no. 1091: BAD Poly: EL = -1.051050e+00 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:54.176 2009  to  Fri Mar 20 19:02:54.176 2009   (  0.00) secs
                     EL bad poly no. 1147: BAD Poly: EL = -1.050898e+00 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:02:57.226 2009  to  Fri Mar 20 19:02:57.226 2009   (  0.00) secs
                     EL bad poly no. 1202: BAD Poly: EL = -1.050746e+00 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:00.265 2009  to  Fri Mar 20 19:03:00.265 2009   (  0.00) secs
                     EL bad poly no. 1257: BAD Poly: EL = -1.050594e+00 rad. Too low.

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:03.264 2009  to  Fri Mar 20 19:03:03.264 2009   (  0.00) secs
                     EL bad poly no. 1311: BAD Poly: EL = -1.050444e+00 rad. Too low.

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:06.270 2009  to  Fri Mar 20 19:03:06.270 2009   (  0.00) secs
                     EL bad poly no. 1366: BAD Poly: EL = -1.050294e+00 rad. Too low.

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Mar 20 19:03:09.270 2009  to  Fri Mar 20 19:03:09.270 2009   (  0.00) secs
                     EL bad poly no. 1421: BAD Poly: EL = -1.050144e+00 rad. Too low.

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Mar 20 19:10:35.433 2009  to  Fri Mar 20 19:10:35.433 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  41  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Mar 20 19:10:35.621 2009  to  Fri Mar 20 19:10:35.621 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  42  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Mar 20 19:10:35.623 2009  to  Fri Mar 20 19:10:35.623 2009   (  0.00) secs
                     Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  43  STARTUP   LSS        startup                                                       Fri Mar 20 20:05:49.736 2009  to  Fri Mar 20 20:05:49.736 2009   (  0.00) secs
                     The LSS was started.

  44  STARTUP   IIF        startup                                                       Fri Mar 20 20:06:00.491 2009  to  Fri Mar 20 20:06:00.491 2009   (  0.00) secs
                     IIF subsystem started

  45  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:06:51.202 2009  to  Fri Mar 20 20:06:51.202 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  46  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:06:51.150 2009  to  Fri Mar 20 20:06:51.150 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  47  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:01.293 2009  to  Fri Mar 20 20:07:01.293 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  48  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:01.346 2009  to  Fri Mar 20 20:07:01.346 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  49  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:11.491 2009  to  Fri Mar 20 20:07:11.491 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  50  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:11.439 2009  to  Fri Mar 20 20:07:11.439 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  51  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:21.581 2009  to  Fri Mar 20 20:07:21.581 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  52  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:21.633 2009  to  Fri Mar 20 20:07:21.633 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  53  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:31.726 2009  to  Fri Mar 20 20:07:31.726 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  54  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:31.778 2009  to  Fri Mar 20 20:07:31.778 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  55  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:41.905 2009  to  Fri Mar 20 20:07:41.905 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  56  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:41.869 2009  to  Fri Mar 20 20:07:41.869 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  57  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:07:51.997 2009  to  Fri Mar 20 20:07:51.997 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  58  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:07:52.050 2009  to  Fri Mar 20 20:07:52.050 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  59  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:02.132 2009  to  Fri Mar 20 20:08:02.132 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  60  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:02.185 2009  to  Fri Mar 20 20:08:02.185 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  61  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:12.328 2009  to  Fri Mar 20 20:08:12.328 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  62  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:12.276 2009  to  Fri Mar 20 20:08:12.276 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  63  STARTUP   PCS        startup                                                       Fri Mar 20 20:08:13.989 2009  to  Fri Mar 20 20:08:13.989 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

  64  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:22.420 2009  to  Fri Mar 20 20:08:22.420 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  65  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:22.472 2009  to  Fri Mar 20 20:08:22.472 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  66  STARTUP   OSS        startup                                                       Fri Mar 20 20:08:27.261 2009  to  Fri Mar 20 20:08:27.261 2009   (  0.00) secs
                     The oss was started.

  67  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:08:32.564 2009  to  Fri Mar 20 20:08:32.564 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  68  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:08:32.616 2009  to  Fri Mar 20 20:08:32.616 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  69  FAILED    PMC        actuator.telemetryError                                       Fri Mar 20 20:08:45.287 2009  to  Fri Mar 20 20:08:45.287 2009   (  0.00) secs
                     left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  70  STARTUP   PMC        startup                                                       Fri Mar 20 20:08:48.422 2009  to  Fri Mar 20 20:08:48.422 2009   (  0.00) secs
                     left PMC subsystem started, version 4.7

  71  FAILED    PMC        actuator.telemetryError                                       Fri Mar 20 20:08:57.620 2009  to  Fri Mar 20 20:08:57.620 2009   (  0.00) secs
                     right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  72  STARTUP   PMC        startup                                                       Fri Mar 20 20:09:01.451 2009  to  Fri Mar 20 20:09:01.451 2009   (  0.00) secs
                     right PMC subsystem started, version 4.7

  73  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:06.411 2009  to  Fri Mar 20 20:09:06.411 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  74  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:06.359 2009  to  Fri Mar 20 20:09:06.359 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  75  STARTUP   PSF        startup                                                       Fri Mar 20 20:09:08.497 2009  to  Fri Mar 20 20:09:08.497 2009   (  0.00) secs
                     left PSF subsystem started, version 4.32

  76  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:16.498 2009  to  Fri Mar 20 20:09:16.498 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  77  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:16.551 2009  to  Fri Mar 20 20:09:16.551 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  78  STARTUP   PSF        startup                                                       Fri Mar 20 20:09:17.160 2009  to  Fri Mar 20 20:09:17.160 2009   (  0.00) secs
                     right PSF subsystem started, version 4.32

  79  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:26.693 2009  to  Fri Mar 20 20:09:26.693 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  80  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:26.745 2009  to  Fri Mar 20 20:09:26.745 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  81  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:36.837 2009  to  Fri Mar 20 20:09:36.837 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  82  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:36.889 2009  to  Fri Mar 20 20:09:36.889 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  83  FAILED    ECS        hydraulicBearing.badPMCData                                   Fri Mar 20 20:09:47.032 2009  to  Fri Mar 20 20:09:47.032 2009   (  0.00) secs
                     ECS hydraulic bearing setpoint: no current PMC thermal data

  84  FAILED    ECS        instrumentCooling.badPMCData                                  Fri Mar 20 20:09:46.980 2009  to  Fri Mar 20 20:09:46.980 2009   (  0.00) secs
                     ECS instrument cooling setpoint: no current PMC thermal data

  85  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:10:51.113 2009  to  Fri Mar 20 20:10:51.113 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  86  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:13:33.026 2009  to  Fri Mar 20 20:13:33.026 2009   (  0.00) secs
                    

  87  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:16:23.462 2009  to  Fri Mar 20 20:16:23.462 2009   (  0.00) secs
                    

  88  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:20:08.821 2009  to  Fri Mar 20 20:20:08.821 2009   (  0.00) secs
                    

  89  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:20:08.844 2009  to  Fri Mar 20 20:20:08.844 2009   (  0.00) secs
                    

  90  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:21:42.347 2009  to  Fri Mar 20 20:21:42.347 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  91  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Mar 20 20:21:46.350 2009  to  Fri Mar 20 20:21:46.350 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  92  FAILED    MCS.MCSPU  MCSPU.ELDrive.amplifierFail                                   Fri Mar 20 20:21:46.460 2009  to  Fri Mar 20 20:21:46.460 2009   (  0.00) secs
                     EL:FL pwr amp(s) NOT normal. power amplifier has (or amplifiers have) failed.

  93  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:22:59.560 2009  to  Fri Mar 20 20:22:59.560 2009   (  0.00) secs
                    

  94  SXDXBOTH  MCS.MCSPU  MCSPU.MEncoders.earlyStrobe                                   Fri Mar 20 20:22:59.583 2009  to  Fri Mar 20 20:22:59.583 2009   (  0.00) secs
                    

  95  FAILED    PMC        VxInterface.close                                             Fri Mar 20 20:47:55.856 2009  to  Fri Mar 20 20:47:55.856 2009   (  0.00) secs
                     left PMC Mirror closing network connection

  96  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 20:47:55.804 2009  to  Fri Mar 20 20:47:55.804 2009   (  0.00) secs
                     left PMC Mirror length error: expected 92, got 96

  97  SEQERROR  PCS        telescope.command.stopTracking                                Fri Mar 20 20:59:35.826 2009  to  Fri Mar 20 20:59:35.830 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  98  SEQERROR  PCS        telescope.command.stopTracking                                Fri Mar 20 20:59:35.962 2009  to  Fri Mar 20 20:59:35.962 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  99  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 21:06:34.208 2009  to  Fri Mar 20 21:06:34.762 2009   (  0.55) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491117122685185e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.511091497144084e+00 El: -2.447831956774970e-01
                     IIF Preset command failed for both LBC mode TRACK from IIF

 100  FAILED    PCS        telescope.command.setEquatorialTarget                         Fri Mar 20 21:06:34.586 2009  to  Fri Mar 20 21:06:34.639 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 RotMode: IDLE Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.511091497144084e+00 El: -2.447831956774970e-01

 101  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 21:11:09.966 2009  to  Fri Mar 20 21:11:10.474 2009   (  0.51) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491117442129629e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                     IIF Preset alert for both LBC mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.525078554421745e+00 El: -2.565014359979753e-01
                     IIF Preset command failed for both LBC mode TRACK from IIF

 102  FAILED    PCS        telescope.command.setEquatorialTarget                         Fri Mar 20 21:11:10.299 2009  to  Fri Mar 20 21:11:10.354 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 RotMode: IDLE Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 0.000000000000000e+00 Dec: 4.712388980384690e-01 Az: 5.525078554421745e+00 El: -2.565014359979753e-01

 103  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 21:15:43.672 2009  to  Fri Mar 20 21:16:44.859 2009   ( 61.19) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 104  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 21:15:43.797 2009  to  Fri Mar 20 21:16:44.690 2009   ( 60.89) secs
                     right PSF ApplyZernikes failed

 105  FAILED    PSF        command.setZernikes                                           Fri Mar 20 21:15:43.744 2009  to  Fri Mar 20 21:16:44.745 2009   ( 61.00) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 106  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 21:15:43.960 2009  to  Fri Mar 20 21:16:44.635 2009   ( 60.68) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 107  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 21:16:29.437 2009  to  Fri Mar 20 21:16:44.517 2009   ( 15.08) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 108  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 21:16:29.379 2009  to  Fri Mar 20 21:16:44.580 2009   ( 15.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 109  FAILED    PMC        VxInterface.close                                             Fri Mar 20 21:33:34.039 2009  to  Fri Mar 20 21:33:34.039 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 110  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 21:33:33.986 2009  to  Fri Mar 20 21:33:33.986 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 111  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:38.337 2009  to  Fri Mar 20 21:56:38.337 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 112  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:38.593 2009  to  Fri Mar 20 21:56:38.593 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 113  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:39.859 2009  to  Fri Mar 20 21:56:39.859 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 114  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.114 2009  to  Fri Mar 20 21:56:40.114 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 115  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.369 2009  to  Fri Mar 20 21:56:40.369 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 116  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:40.624 2009  to  Fri Mar 20 21:56:40.624 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 117  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:42.295 2009  to  Fri Mar 20 21:56:42.295 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

 118  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:42.550 2009  to  Fri Mar 20 21:56:42.550 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

 119  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:43.412 2009  to  Fri Mar 20 21:56:43.412 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 120  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:50.142 2009  to  Fri Mar 20 21:56:50.142 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 121  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:56:58.494 2009  to  Fri Mar 20 21:56:58.494 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 122  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:03.204 2009  to  Fri Mar 20 21:57:03.204 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 123  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:03.459 2009  to  Fri Mar 20 21:57:03.459 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 124  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:04.523 2009  to  Fri Mar 20 21:57:04.523 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

 125  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:04.777 2009  to  Fri Mar 20 21:57:04.777 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

 126  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.032 2009  to  Fri Mar 20 21:57:05.032 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 4.0066242e-04 -3.5268068e-04 3.2435656e-03 5.8964252e-02 7.8582764e-02 1.3921261e-02

 127  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.490 2009  to  Fri Mar 20 21:57:05.490 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 128  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:05.746 2009  to  Fri Mar 20 21:57:05.746 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 129  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:06.002 2009  to  Fri Mar 20 21:57:06.002 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 130  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:09.088 2009  to  Fri Mar 20 21:57:09.088 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.6231022e-04 -6.4808130e-04 3.0618310e-03 5.2397966e-02 1.0031891e-01 3.6280155e-03

 131  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:10.977 2009  to  Fri Mar 20 21:57:10.977 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 132  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:11.232 2009  to  Fri Mar 20 21:57:11.232 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 133  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:11.892 2009  to  Fri Mar 20 21:57:11.892 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 134  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:12.147 2009  to  Fri Mar 20 21:57:12.147 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 135  FAILED    PSF        primaryMirror.positionError                                   Fri Mar 20 21:57:13.414 2009  to  Fri Mar 20 21:57:13.414 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 5.8591366e-04 -6.5732002e-04 3.0511618e-03 7.5420856e-02 6.1054230e-02 2.4820805e-02

 136  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 23:05:20.053 2009  to  Fri Mar 20 23:05:40.483 2009   ( 20.43) secs
                     right PSF SetInstrumentOffsets failed

 137  FAILED    IIF        command.moveFocus                                             Fri Mar 20 23:05:19.990 2009  to  Fri Mar 20 23:05:40.650 2009   ( 20.66) secs
                     IIF MoveFocus command started for right LBC for 2.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.000000000000000e-01

 138  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 23:05:20.105 2009  to  Fri Mar 20 23:05:40.428 2009   ( 20.32) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 139  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:05:20.220 2009  to  Fri Mar 20 23:05:40.310 2009   ( 20.09) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 140  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:05:20.157 2009  to  Fri Mar 20 23:05:40.373 2009   ( 20.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 141  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:09:51.013 2009  to  Fri Mar 20 23:09:51.013 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 142  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:09:51.065 2009  to  Fri Mar 20 23:09:51.065 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 143  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:12:07.342 2009  to  Fri Mar 20 23:12:07.342 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:12:07.287 2009  to  Fri Mar 20 23:12:07.287 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 145  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:13:14.981 2009  to  Fri Mar 20 23:13:14.981 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 146  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:13:47.472 2009  to  Fri Mar 20 23:13:47.472 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 147  SEQERROR  PSF        primaryMirror.command.setZernikes                             Fri Mar 20 23:13:55.006 2009  to  Fri Mar 20 23:14:55.279 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror getting Zernike coefficients

 148  SEQERROR  PSF        primaryMirror.command.setZernikes                             Fri Mar 20 23:14:03.243 2009  to  Fri Mar 20 23:14:03.243 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror Zernike coefficients received

 149  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Fri Mar 20 23:16:38.483 2009  to  Fri Mar 20 23:19:34.661 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror initForceCalc started

 150  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Fri Mar 20 23:16:38.599 2009  to  Fri Mar 20 23:16:38.599 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror initForceCalc complete for 12 modes, FCin flag 0

 151  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:23:25.160 2009  to  Fri Mar 20 23:23:30.163 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 152  SEQERROR  IIF        command.authorize                                             Fri Mar 20 23:23:28.211 2009  to  Fri Mar 20 23:23:28.211 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 153  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:24:05.835 2009  to  Fri Mar 20 23:24:05.835 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:24:05.783 2009  to  Fri Mar 20 23:24:05.783 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 155  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:25:40.040 2009  to  Fri Mar 20 23:26:52.934 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 156  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:25:57.161 2009  to  Fri Mar 20 23:26:52.997 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

 157  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:26:11.240 2009  to  Fri Mar 20 23:26:11.240 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

 158  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:26:20.301 2009  to  Fri Mar 20 23:26:20.301 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 159  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:27:59.948 2009  to  Fri Mar 20 23:27:59.948 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 160  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:28:00.005 2009  to  Fri Mar 20 23:28:00.005 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 161  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:28:49.201 2009  to  Fri Mar 20 23:31:20.812 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 162  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:29:17.333 2009  to  Fri Mar 20 23:29:17.333 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

 163  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:29:29.012 2009  to  Fri Mar 20 23:29:29.012 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 164  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:29:35.534 2009  to  Fri Mar 20 23:28:58.272 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 165  SEQERROR  IIF        command.moveFocus                                             Fri Mar 20 23:31:31.059 2009  to  Fri Mar 20 23:36:25.026 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF MoveFocus command started for left LBC for 0.000000000000000e+00

 166  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:31:31.302 2009  to  Fri Mar 20 23:34:43.332 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started

 167  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 23:39:17.845 2009  to  Fri Mar 20 23:39:17.845 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 168  FAILED    PMC        VxInterface.close                                             Fri Mar 20 23:39:17.945 2009  to  Fri Mar 20 23:39:17.945 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 169  FAILED    IIF        command.preset.(TRACK)                                        Fri Mar 20 23:48:46.060 2009  to  Fri Mar 20 23:48:55.011 2009   (  8.95) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for both LBC mode TRACK from IIF

 170  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 23:48:48.738 2009  to  Fri Mar 20 23:48:54.802 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 171  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:48:48.674 2009  to  Fri Mar 20 23:48:54.888 2009   (  6.21) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 172  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 23:48:56.295 2009  to  Fri Mar 20 23:55:09.066 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror setLocalOffsets started

 173  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 23:52:21.547 2009  to  Fri Mar 20 23:52:21.547 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 174  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:00:48.696 2009  to  Sat Mar 21 00:00:48.696 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 175  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:00:48.644 2009  to  Sat Mar 21 00:00:48.644 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 176  SEQERROR  IIF        command.authorize                                             Sat Mar 21 00:03:27.656 2009  to  Sat Mar 21 00:03:27.656 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 177  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 00:03:44.972 2009  to  Sat Mar 21 00:15:07.647 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491130216435185e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

 178  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 00:05:18.006 2009  to  Sat Mar 21 00:15:07.708 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

 179  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 00:05:30.189 2009  to  Sat Mar 21 00:05:30.189 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

 180  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 00:05:33.266 2009  to  Sat Mar 21 00:05:33.266 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491129425925926e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

 181  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 00:06:27.469 2009  to  Sat Mar 21 00:06:27.469 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror setLocalOffsets complete

 182  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 00:06:27.525 2009  to  Sat Mar 21 00:06:27.525 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetInstrumentOffsets complete

 183  SEQERROR  IIF        command.moveFocus                                             Sat Mar 21 00:06:27.590 2009  to  Sat Mar 21 00:06:27.590 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF MoveFocus command complete for left LBC for -8.000000000000000e-01

 184  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:21:12.115 2009  to  Sat Mar 21 00:21:12.115 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 185  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:21:12.063 2009  to  Sat Mar 21 00:21:12.063 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 186  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:30:02.431 2009  to  Sat Mar 21 00:30:02.431 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 187  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:30:02.378 2009  to  Sat Mar 21 00:30:02.378 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 188  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:37:32.665 2009  to  Sat Mar 21 00:37:32.665 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 189  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:37:32.614 2009  to  Sat Mar 21 00:37:32.614 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 190  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 00:45:08.945 2009  to  Sat Mar 21 00:45:08.945 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 191  FAILED    PMC        VxInterface.close                                             Sat Mar 21 00:45:08.997 2009  to  Sat Mar 21 00:45:08.997 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 192  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 01:15:40.561 2009  to  Sat Mar 21 01:16:00.004 2009   ( 19.44) secs
                     right PSF SetInstrumentOffsets failed

 193  FAILED    IIF        command.moveFocus                                             Sat Mar 21 01:15:40.497 2009  to  Sat Mar 21 01:16:00.174 2009   ( 19.68) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491134422453704e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 194  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 01:15:40.613 2009  to  Sat Mar 21 01:15:59.947 2009   ( 19.33) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 195  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 01:15:40.729 2009  to  Sat Mar 21 01:15:59.820 2009   ( 19.09) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 196  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 01:15:40.666 2009  to  Sat Mar 21 01:15:59.889 2009   ( 19.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 197  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 01:41:59.825 2009  to  Sat Mar 21 01:41:59.825 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 198  FAILED    PMC        VxInterface.close                                             Sat Mar 21 01:41:59.876 2009  to  Sat Mar 21 01:41:59.876 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 199  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 02:51:25.196 2009  to  Sat Mar 21 02:51:25.196 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 200  FAILED    PMC        VxInterface.close                                             Sat Mar 21 02:51:25.248 2009  to  Sat Mar 21 02:51:25.248 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 201  FAILED    PMC        VxInterface.close                                             Sat Mar 21 02:53:54.926 2009  to  Sat Mar 21 02:53:54.926 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 202  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 02:53:54.873 2009  to  Sat Mar 21 02:53:54.873 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

 203  FAILED    PMC        VxInterface.close                                             Sat Mar 21 03:01:53.054 2009  to  Sat Mar 21 03:01:53.054 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 204  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 03:01:53.002 2009  to  Sat Mar 21 03:01:53.002 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 205  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:09:07.103 2009  to  Sat Mar 21 03:09:13.744 2009   (  6.64) secs
                     IIF MoveFocus command started for right LBC for 8.000000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 8.000000000000000e-02

 206  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:09:07.167 2009  to  Sat Mar 21 03:09:13.576 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 207  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:09:07.219 2009  to  Sat Mar 21 03:09:13.520 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 208  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:09:07.271 2009  to  Sat Mar 21 03:09:13.464 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 209  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:09:07.332 2009  to  Sat Mar 21 03:09:13.397 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 210  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:13:55.298 2009  to  Sat Mar 21 03:15:36.852 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 211  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 03:14:15.947 2009  to  Sat Mar 21 03:14:42.729 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491142687500000e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

 212  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 03:14:16.009 2009  to  Sat Mar 21 03:22:21.256 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

 213  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 03:14:19.160 2009  to  Sat Mar 21 03:14:19.160 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

 214  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 03:14:38.758 2009  to  Sat Mar 21 03:14:38.758 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491142656250000e+04, time 4.650000000000000e+02, interval 1.000000000000000e+00

 215  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:14:41.904 2009  to  Sat Mar 21 03:14:41.904 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror force adjustments complete

 216  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:17:15.532 2009  to  Sat Mar 21 03:22:05.667 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

 217  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:18:11.408 2009  to  Sat Mar 21 03:18:11.408 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF ApplyZernikes complete

 218  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:21.348 2009  to  Sat Mar 21 03:26:26.399 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 219  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:30.441 2009  to  Sat Mar 21 03:26:30.441 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 220  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:38.000 2009  to  Sat Mar 21 03:26:43.003 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 221  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:49.501 2009  to  Sat Mar 21 03:26:16.392 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 222  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:54.460 2009  to  Sat Mar 21 03:26:21.348 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 223  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:26:57.513 2009  to  Sat Mar 21 03:26:57.513 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 224  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:27:08.555 2009  to  Sat Mar 21 03:27:08.555 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 225  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:27:32.551 2009  to  Sat Mar 21 03:27:32.551 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 226  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 03:29:00.674 2009  to  Sat Mar 21 03:30:12.310 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for left LBC for M1

 227  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 03:29:00.744 2009  to  Sat Mar 21 03:30:15.972 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF SetZernikes started for 28 coefficients to ope M1

 228  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:29:00.796 2009  to  Sat Mar 21 03:30:16.025 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

 229  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:29:00.956 2009  to  Sat Mar 21 03:30:16.189 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 230  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 03:29:04.609 2009  to  Sat Mar 21 03:29:04.609 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetZernikes complete for 28 coefficient to ope M1

 231  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:29:21.738 2009  to  Sat Mar 21 03:30:14.425 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Guide command started for right LBC, coord1 1.074205966815659e-06, coord2 6.727076083712780e-07, rotation angle 0.000000000000000e+00

 232  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:29:31.042 2009  to  Sat Mar 21 03:29:31.042 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Guide command complete for right LBC, coord1 3.470147596268452e-07, coord2 2.765438789698833e-07, rotation angle 0.000000000000000e+00

 233  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 03:29:49.665 2009  to  Sat Mar 21 03:29:49.665 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for left LBC for M1

 234  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:32:08.931 2009  to  Sat Mar 21 03:33:54.924 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started

 235  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:32:08.868 2009  to  Sat Mar 21 03:33:54.858 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 236  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:32:38.268 2009  to  Sat Mar 21 03:34:43.857 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Guide command started for right LBC, coord1 0.000000000000000e+00, coord2 0.000000000000000e+00, rotation angle 0.000000000000000e+00

 237  SEQERROR  IIF        command.guide                                                 Sat Mar 21 03:33:16.036 2009  to  Sat Mar 21 03:33:16.036 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Guide command complete for right LBC, coord1 0.000000000000000e+00, coord2 0.000000000000000e+00, rotation angle 0.000000000000000e+00

 238  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 03:34:56.613 2009  to  Sat Mar 21 03:37:37.659 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF ApplyZernikes started

 239  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 03:34:56.774 2009  to  Sat Mar 21 03:37:37.822 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting primary mirror forces

 240  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:34:57.015 2009  to  Sat Mar 21 03:36:43.918 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 241  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:36:43.735 2009  to  Sat Mar 21 03:36:51.384 2009   (  7.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491144217592593e+04, time 4.350000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 7.800000000000000e-02

 242  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:36:43.797 2009  to  Sat Mar 21 03:36:51.216 2009   (  7.42) secs
                     right PSF SetInstrumentOffsets failed

 243  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:36:43.850 2009  to  Sat Mar 21 03:36:51.159 2009   (  7.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 244  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:36:43.903 2009  to  Sat Mar 21 03:36:51.103 2009   (  7.20) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 245  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:36:43.971 2009  to  Sat Mar 21 03:36:51.039 2009   (  7.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 246  FAILED    PMC        mirror.panic                                                  Sat Mar 21 03:44:09.801 2009  to  Sat Mar 21 03:44:09.801 2009   (  0.00) secs
                     right PMC ** PANIC: Disabled actuator set invalid

 247  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 03:44:50.038 2009  to  Sat Mar 21 03:44:50.436 2009   (  0.40) secs
                     right PSF SetInstrumentOffsets failed

 248  FAILED    IIF        command.moveFocus                                             Sat Mar 21 03:44:49.975 2009  to  Sat Mar 21 03:44:50.603 2009   (  0.63) secs
                     IIF MoveFocus command started for right LBC for 6.000000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 6.000000000000000e-02

 249  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 03:44:50.091 2009  to  Sat Mar 21 03:44:50.380 2009   (  0.29) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 250  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 03:44:50.204 2009  to  Sat Mar 21 03:44:50.257 2009   (  0.05) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 251  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 03:44:50.144 2009  to  Sat Mar 21 03:44:50.324 2009   (  0.18) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 252  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:52.717 2009  to  Sat Mar 21 03:59:47.716 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 253  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:55.773 2009  to  Sat Mar 21 03:59:55.773 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 254  SEQERROR  IIF        command.authorize                                             Sat Mar 21 03:59:56.766 2009  to  Sat Mar 21 03:59:56.766 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 255  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:00:05.693 2009  to  Sat Mar 21 03:59:52.717 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 256  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:02:34.681 2009  to  Sat Mar 21 04:05:24.859 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF GetTrajectory command started for both LBC, start time 5.491146208333333e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

 257  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:02:46.129 2009  to  Sat Mar 21 04:05:24.920 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

 258  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:02:49.240 2009  to  Sat Mar 21 04:02:49.240 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

 259  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:03:35.378 2009  to  Sat Mar 21 04:03:35.378 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491146011574074e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00

 260  SEQERROR  PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 04:04:06.729 2009  to  Sat Mar 21 04:04:06.729 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror setLocalOffsets complete

 261  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 04:04:06.784 2009  to  Sat Mar 21 04:04:06.784 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetInstrumentOffsets complete

 262  SEQERROR  PSF        command.setInstrumentOffsets                                  Sat Mar 21 04:04:09.839 2009  to  Sat Mar 21 04:04:09.839 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetInstrumentOffsets complete

 263  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Sat Mar 21 04:11:58.061 2009  to  Sat Mar 21 04:11:58.061 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror initForceCalc complete for 2 modes, FCin flag 0

 264  SEQERROR  PSF        primaryMirror.command.initForceCalc                           Sat Mar 21 04:12:01.190 2009  to  Sat Mar 21 04:26:48.063 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror initForceCalc started

 265  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:13:07.458 2009  to  Sat Mar 21 04:13:07.458 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

 266  SEQERROR  PSF        command.applyZernikes                                         Sat Mar 21 04:13:07.514 2009  to  Sat Mar 21 04:13:07.514 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF ApplyZernikes complete

 267  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:13:07.570 2009  to  Sat Mar 21 04:13:07.570 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetZernikes complete for 28 coefficient to ope M1

 268  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:13:07.633 2009  to  Sat Mar 21 04:13:07.633 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for right LBC for M1

 269  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:14:48.040 2009  to  Sat Mar 21 04:15:32.499 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 270  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:11.016 2009  to  Sat Mar 21 04:15:54.080 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 271  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:21.042 2009  to  Sat Mar 21 04:15:48.961 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 272  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:27.520 2009  to  Sat Mar 21 04:15:21.042 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 273  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:37.501 2009  to  Sat Mar 21 04:15:43.980 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Authorize command started for both LBC at prime focus (IIF both side)

 274  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:15:52.013 2009  to  Sat Mar 21 04:15:52.013 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 275  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:16:33.647 2009  to  Sat Mar 21 04:16:33.647 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 276  SEQERROR  IIF        command.authorize                                             Sat Mar 21 04:16:33.649 2009  to  Sat Mar 21 04:16:33.649 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF Authorize command complete for both LBC at prime focus (IIF both side)

 277  FAILED    IIF        command.sendWavefront                                         Sat Mar 21 04:26:47.516 2009  to  Sat Mar 21 04:27:02.494 2009   ( 14.98) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 278  FAILED    PSF        command.applyZernikes                                         Sat Mar 21 04:26:47.638 2009  to  Sat Mar 21 04:27:02.322 2009   ( 14.68) secs
                     right PSF ApplyZernikes failed

 279  FAILED    PSF        command.setZernikes                                           Sat Mar 21 04:26:47.585 2009  to  Sat Mar 21 04:27:02.378 2009   ( 14.79) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 280  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:26:47.870 2009  to  Sat Mar 21 04:27:02.266 2009   ( 14.40) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 281  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 04:26:51.009 2009  to  Sat Mar 21 04:27:02.210 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 282  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 04:26:51.071 2009  to  Sat Mar 21 04:27:02.144 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 283  FAILED    PMC        VxInterface.close                                             Sat Mar 21 04:32:46.632 2009  to  Sat Mar 21 04:32:46.632 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 284  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 04:32:46.581 2009  to  Sat Mar 21 04:32:46.581 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 285  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:35:20.157 2009  to  Sat Mar 21 04:35:20.157 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF SetZernikes complete for 28 coefficient to ope M1

 286  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:35:20.220 2009  to  Sat Mar 21 04:35:20.220 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for right LBC for M1

 287  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:37:01.031 2009  to  Sat Mar 21 04:38:28.265 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF adjusting primary mirror forces

 288  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Sat Mar 21 04:38:02.457 2009  to  Sat Mar 21 04:38:02.457 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror force adjustments complete

 289  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:47:24.604 2009  to  Sat Mar 21 04:49:28.039 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF SendWavefront command started for left LBC for M1

 290  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:47:48.234 2009  to  Sat Mar 21 04:49:28.106 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF SetZernikes started for 28 coefficients to ope M1

 291  SEQERROR  PSF        command.setZernikes                                           Sat Mar 21 04:48:32.368 2009  to  Sat Mar 21 04:48:32.368 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF SetZernikes complete for 28 coefficient to ope M1

 292  SEQERROR  IIF        command.sendWavefront                                         Sat Mar 21 04:48:32.434 2009  to  Sat Mar 21 04:48:32.434 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF SendWavefront command complete for left LBC for M1

 293  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:50:16.593 2009  to  Sat Mar 21 04:52:18.279 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS starting get rotator trajectory

 294  SEQERROR  PCS        rotator.command.getRotatorTrajectory                          Sat Mar 21 04:50:39.793 2009  to  Sat Mar 21 04:50:39.793 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS finished get rotator trajectory

 295  SEQERROR  IIF        command.getTrajectory                                         Sat Mar 21 04:50:49.567 2009  to  Sat Mar 21 04:50:49.567 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF GetTrajectory command complete for both LBC, start time 5.491149311342592e+04, time 3.900000000000000e+02, interval 1.000000000000000e+00

 296  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 04:54:57.074 2009  to  Sat Mar 21 04:54:57.074 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 297  FAILED    PMC        VxInterface.close                                             Sat Mar 21 04:54:57.126 2009  to  Sat Mar 21 04:54:57.126 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 298  FAILED    IIF        command.moveFocus                                             Sat Mar 21 05:12:36.443 2009  to  Sat Mar 21 05:12:43.095 2009   (  6.65) secs
                     IIF MoveFocus command started for left LBC for 0.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.390000000000000e-01

 299  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 05:12:36.509 2009  to  Sat Mar 21 05:12:42.925 2009   (  6.42) secs
                     right PSF SetInstrumentOffsets failed

 300  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 05:12:36.615 2009  to  Sat Mar 21 05:12:42.815 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 301  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 05:12:36.562 2009  to  Sat Mar 21 05:12:42.870 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 302  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 05:12:36.681 2009  to  Sat Mar 21 05:12:42.748 2009   (  6.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 303  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:15:12.941 2009  to  Sat Mar 21 05:15:12.941 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 304  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:15:12.889 2009  to  Sat Mar 21 05:15:12.889 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 305  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:21:43.040 2009  to  Sat Mar 21 05:21:43.040 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 306  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:21:43.091 2009  to  Sat Mar 21 05:21:43.091 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 307  FAILED    PMC        VxInterface.close                                             Sat Mar 21 05:27:20.332 2009  to  Sat Mar 21 05:27:20.332 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 308  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 05:27:20.279 2009  to  Sat Mar 21 05:27:20.279 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 309  FAILED    PMC        VxInterface.lengthError                                       Sat Mar 21 06:02:18.561 2009  to  Sat Mar 21 06:02:18.561 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 310  FAILED    PMC        VxInterface.close                                             Sat Mar 21 06:02:18.614 2009  to  Sat Mar 21 06:02:18.614 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 311  FAILED    IIF        command.moveFocus                                             Sat Mar 21 06:05:41.032 2009  to  Sat Mar 21 06:05:47.673 2009   (  6.64) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.200000000000000e-01

 312  FAILED    PSF        command.setInstrumentOffsets                                  Sat Mar 21 06:05:41.097 2009  to  Sat Mar 21 06:05:47.505 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 313  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Mar 21 06:05:41.150 2009  to  Sat Mar 21 06:05:47.449 2009   (  6.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 314  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Mar 21 06:05:41.262 2009  to  Sat Mar 21 06:05:47.330 2009   (  6.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 315  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Mar 21 06:05:41.201 2009  to  Sat Mar 21 06:05:47.394 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

**********************************************************
    Reporting period ending:   Sat Mar 21 06:51:56.472 2009
********************************************************************************************************