You are here: Foswiki>Software Web>TCSSWReportFile_090319 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 19 2009 to Mar 20 2009
 
    Reporting period beginning:   Thu Mar 19 18:00:00.398 2009
    Reporting period ending:      Fri Mar 20 06:52:55.656 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.33    2.53    2.29    2.76     0.0 %          2                     2           
                                                                                                   

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Mar 19 18:23:38.271 2009  to  Thu Mar 19 18:23:41.035 2009   (  2.76) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Mar 19 18:23:38.335 2009  to  Thu Mar 19 18:23:40.629 2009   (  2.29) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for right LBC at prime focus: right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for right LBC at prime focus: right PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.05    0.04    0.12   100.0 %        354        354                      
                                                                       0.01    0.05    0.04    0.12
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.13    0.35    0.23    0.87   100.0 %        607        607                      
                                                                       0.13    0.35    0.23    0.87
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.05    0.22    0.19    0.34   100.0 %         10         10                      
                                                                       0.05    0.22    0.19    0.34
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.48    6.34    2.52   84.89    99.5 %        599        596          3           
                                                                       6.50    6.34    2.52   84.89
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .   97.98   40.80    4.79  301.14    88.2 %         17         15          2               timeout =     2
                                                                       1.40    6.10    4.79    8.97
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.42    5.40    4.06    8.27    88.2 %         17         15                      
                                                                       1.42    5.40    4.06    8.27
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   15.22   27.46    1.06   47.14    92.3 %         13         12                      
                                                                      15.22   27.46    1.06   47.14
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   13.01    5.83    2.07   47.15   100.0 %         12         12                      
                                                                      13.01    5.83    2.07   47.15
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   31.03   54.03   10.53   96.68    92.3 %         13         12          1                 abort =     1
                                                                      29.85   57.38   10.53   96.68
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    4.62    9.14    0.65   43.34    98.5 %        397        391          6           
                                                                       4.53    9.04    0.65   43.34

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             4

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Thu Mar 19 18:28:50.664 2009  to  Thu Mar 19 18:29:04.469 2009   ( 13.81) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command aborted for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

   2  SEQERROR  IIF        command.preset.elevationWait                                  Thu Mar 19 18:28:52.287 2009  to  Thu Mar 19 19:30:49.237 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

   3  FAILED    IIF        command.offset                                                Thu Mar 19 18:30:48.538 2009  to  Thu Mar 19 18:35:49.678 2009   (301.14) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

   4  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 19 18:30:48.956 2009  to  Thu Mar 19 18:36:18.428 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

   5  FAILED    IIF        command.offset                                                Thu Mar 19 18:36:18.094 2009  to  Thu Mar 19 18:41:19.156 2009   (301.06) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

   6  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 19 18:36:18.428 2009  to  Thu Mar 19 18:54:16.321 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

   7  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 20:21:59.959 2009  to  Thu Mar 19 20:22:11.177 2009   ( 11.22) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   8  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 20:34:04.451 2009  to  Thu Mar 19 20:34:14.553 2009   ( 10.10) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

   9  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 21:31:30.684 2009  to  Thu Mar 19 21:31:44.758 2009   ( 14.07) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  10  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 01:13:56.801 2009  to  Fri Mar 20 01:14:11.193 2009   ( 14.39) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  11  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 03:02:24.446 2009  to  Fri Mar 20 03:02:53.534 2009   ( 29.09) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  12  FAILED    IIF        command.moveFocus                                             Fri Mar 20 04:35:03.120 2009  to  Fri Mar 20 04:35:11.772 2009   (  8.65) secs
                     IIF MoveFocus command started for right LBC for 2.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.000000000000000e-01

  13  FAILED    IIF        command.moveFocus                                             Fri Mar 20 04:38:22.266 2009  to  Fri Mar 20 04:38:27.902 2009   (  5.64) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.200000000000000e-01

  14  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 05:25:39.128 2009  to  Fri Mar 20 05:25:52.132 2009   ( 13.00) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  15  FAILED    IIF        command.moveFocus                                             Fri Mar 20 05:26:14.838 2009  to  Fri Mar 20 05:26:21.485 2009   (  6.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491051822916666e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3823                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7646                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      72                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         16                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                469           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            14
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            35
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.torqueLimit. . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnTimeOut. . . . . . . . . . . . . . . . . .                  3           
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  4           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Tracker.unexpectedVelMode. . . . . . . . . . . . . . . .                  1           
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .      64                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .      60                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     180                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  3           
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:00.398 2009  to  Thu Mar 19 18:00:00.398 2009   (  0.00) secs
                     EL bad poly no. 105003: BAD Poly: EL = -1.154589e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:03.399 2009  to  Thu Mar 19 18:00:03.399 2009   (  0.00) secs
                     EL bad poly no. 105053: BAD Poly: EL = -1.154945e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:06.438 2009  to  Thu Mar 19 18:00:06.438 2009   (  0.00) secs
                     EL bad poly no. 105109: BAD Poly: EL = -1.155307e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:09.495 2009  to  Thu Mar 19 18:00:09.495 2009   (  0.00) secs
                     EL bad poly no. 105162: BAD Poly: EL = -1.155670e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:12.498 2009  to  Thu Mar 19 18:00:12.498 2009   (  0.00) secs
                     EL bad poly no. 105214: BAD Poly: EL = -1.156027e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:15.556 2009  to  Thu Mar 19 18:00:15.556 2009   (  0.00) secs
                     EL bad poly no. 105272: BAD Poly: EL = -1.156390e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:18.569 2009  to  Thu Mar 19 18:00:18.569 2009   (  0.00) secs
                     EL bad poly no. 105328: BAD Poly: EL = -1.156747e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:21.578 2009  to  Thu Mar 19 18:00:21.578 2009   (  0.00) secs
                     EL bad poly no. 105382: BAD Poly: EL = -1.157104e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:24.624 2009  to  Thu Mar 19 18:00:24.624 2009   (  0.00) secs
                     EL bad poly no. 105438: BAD Poly: EL = -1.157464e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:27.629 2009  to  Thu Mar 19 18:00:27.629 2009   (  0.00) secs
                     EL bad poly no. 105493: BAD Poly: EL = -1.157820e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:30.645 2009  to  Thu Mar 19 18:00:30.645 2009   (  0.00) secs
                     EL bad poly no. 105548: BAD Poly: EL = -1.158176e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:33.682 2009  to  Thu Mar 19 18:00:33.682 2009   (  0.00) secs
                     EL bad poly no. 105604: BAD Poly: EL = -1.158536e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:36.691 2009  to  Thu Mar 19 18:00:36.691 2009   (  0.00) secs
                     EL bad poly no. 105661: BAD Poly: EL = -1.158891e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:39.721 2009  to  Thu Mar 19 18:00:39.721 2009   (  0.00) secs
                     EL bad poly no. 105716: BAD Poly: EL = -1.159248e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:42.754 2009  to  Thu Mar 19 18:00:42.754 2009   (  0.00) secs
                     EL bad poly no. 105771: BAD Poly: EL = -1.159606e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:45.800 2009  to  Thu Mar 19 18:00:45.800 2009   (  0.00) secs
                     EL bad poly no. 105826: BAD Poly: EL = -1.159965e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:48.829 2009  to  Thu Mar 19 18:00:48.829 2009   (  0.00) secs
                     EL bad poly no. 105882: BAD Poly: EL = -1.160322e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:51.873 2009  to  Thu Mar 19 18:00:51.873 2009   (  0.00) secs
                     EL bad poly no. 105937: BAD Poly: EL = -1.160680e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:54.890 2009  to  Thu Mar 19 18:00:54.890 2009   (  0.00) secs
                     EL bad poly no. 105992: BAD Poly: EL = -1.161035e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:57.892 2009  to  Thu Mar 19 18:00:57.892 2009   (  0.00) secs
                     EL bad poly no. 106047: BAD Poly: EL = -1.161387e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:00.909 2009  to  Thu Mar 19 18:01:00.909 2009   (  0.00) secs
                     EL bad poly no. 106099: BAD Poly: EL = -1.161741e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:03.941 2009  to  Thu Mar 19 18:01:03.941 2009   (  0.00) secs
                     EL bad poly no. 106149: BAD Poly: EL = -1.162097e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:06.951 2009  to  Thu Mar 19 18:01:06.951 2009   (  0.00) secs
                     EL bad poly no. 106203: BAD Poly: EL = -1.162450e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:09.966 2009  to  Thu Mar 19 18:01:09.966 2009   (  0.00) secs
                     EL bad poly no. 106257: BAD Poly: EL = -1.162803e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:13.016 2009  to  Thu Mar 19 18:01:13.016 2009   (  0.00) secs
                     EL bad poly no. 106312: BAD Poly: EL = -1.163160e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Mar 19 18:23:42.042 2009  to  Thu Mar 19 18:23:42.042 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:23:57.744 2009  to  Thu Mar 19 18:23:57.744 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  28  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:24:25.402 2009  to  Thu Mar 19 18:24:25.402 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  29  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:24:29.185 2009  to  Thu Mar 19 18:24:29.185 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  30  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:24:34.807 2009  to  Thu Mar 19 18:24:34.807 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:25:27.111 2009  to  Thu Mar 19 18:25:27.111 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:25:36.511 2009  to  Thu Mar 19 18:25:36.511 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  33  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:25:51.959 2009  to  Thu Mar 19 18:25:51.959 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Thu Mar 19 18:29:10.158 2009  to  Thu Mar 19 18:29:10.158 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Mar 19 18:29:11.199 2009  to  Thu Mar 19 18:29:11.199 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Mar 19 18:29:11.199 2009  to  Thu Mar 19 18:29:11.199 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Mar 20 06:13:27.508 2009  to  Fri Mar 20 06:13:27.508 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  38  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.888 2009  to  Fri Mar 20 06:13:27.888 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  39  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.943 2009  to  Fri Mar 20 06:13:27.943 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  40  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.944 2009  to  Fri Mar 20 06:13:27.944 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  41  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Fri Mar 20 06:13:29.511 2009  to  Fri Mar 20 06:13:29.511 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    0.00   43.77   43.77   43.77   100.0 %          1          1                      
                                                                       0.00   43.77   43.77   43.77

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.00    0.07    0.07    0.08   100.0 %         10         10                      
                                                                       0.00    0.07    0.07    0.08
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.12    0.09    0.25   100.0 %        607        607                      
                                                                       0.02    0.12    0.09    0.25
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %          3          3                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.15    0.34    0.07    0.58   100.0 %         17         17                      
                                                                       0.15    0.34    0.07    0.58
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.10    0.07    0.17   100.0 %         14         14                      
                                                                       0.03    0.10    0.07    0.17
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.52    0.52    0.52   100.0 %          1          1                      
                                                                       0.00    0.52    0.52    0.52
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.62    0.31    0.82   100.0 %         14         14                      
                                                                       0.20    0.62    0.31    0.82
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.06    0.07    0.00    0.12    33.3 %          3          1          2           
                                                                       0.00    0.08    0.08    0.08

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.501 2009  to  Thu Mar 19 18:23:38.649 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   2  FAILED    PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.649 2009  to  Thu Mar 19 18:23:38.766 2009   (  0.12) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   3  SEQERROR  PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.899 2009  to  Thu Mar 19 18:23:38.899 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.74    2.48    2.05    8.07   100.0 %        364        364                      
                                                                       0.74    2.48    2.05    8.07
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.25    2.93    2.05    5.06   100.0 %          8          8                      
                                                                       1.25    2.93    2.05    5.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    5.74    6.21    0.00   84.23    98.9 %       1004        993         11           
                                                                       5.73    6.20    2.05   84.23
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.07   100.0 %          6          6                      
                                                                       0.01    0.06    0.05    0.07

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       8                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 34           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 34           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      34                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     364                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           289
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            29
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  7           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  4           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  3           

PMC Events of Interest

   1  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:00.326 2009  to  Thu Mar 19 18:50:10.142 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   2  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:00.372 2009  to  Thu Mar 19 18:50:11.645 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:10.142 2009  to  Thu Mar 19 18:50:10.195 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:11.645 2009  to  Thu Mar 19 18:50:11.697 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 18:50:35.345 2009  to  Thu Mar 19 18:50:35.345 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Thu Mar 19 18:50:35.398 2009  to  Thu Mar 19 18:50:35.398 2009   (  0.00) secs
                     right PMC Actuator closing network connection

   7  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:36.492 2009  to  Thu Mar 19 18:50:36.492 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:51:24.544 2009  to  Thu Mar 19 18:51:24.544 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

   9  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:11:45.853 2009  to  Thu Mar 19 19:11:45.853 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  10  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:11:45.962 2009  to  Thu Mar 19 19:11:45.962 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  11  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:42:27.571 2009  to  Thu Mar 19 19:42:27.571 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:42:27.624 2009  to  Thu Mar 19 19:42:27.624 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:56:09.504 2009  to  Thu Mar 19 19:56:09.504 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:56:09.452 2009  to  Thu Mar 19 19:56:09.452 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 20:22:03.717 2009  to  Thu Mar 19 20:22:10.783 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 20:34:08.135 2009  to  Thu Mar 19 20:34:14.198 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:04:01.877 2009  to  Thu Mar 19 21:04:01.877 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:04:01.825 2009  to  Thu Mar 19 21:04:01.825 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:21:54.030 2009  to  Thu Mar 19 21:21:54.030 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:21:53.976 2009  to  Thu Mar 19 21:21:53.976 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:21:55.927 2009  to  Thu Mar 19 21:21:55.927 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:21:55.875 2009  to  Thu Mar 19 21:21:55.875 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 21:31:34.332 2009  to  Thu Mar 19 21:31:44.401 2009   ( 10.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:37:36.134 2009  to  Thu Mar 19 21:37:36.134 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:37:36.185 2009  to  Thu Mar 19 21:37:36.185 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:42:25.574 2009  to  Thu Mar 19 21:42:25.574 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:42:25.627 2009  to  Thu Mar 19 21:42:25.627 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:58:34.795 2009  to  Thu Mar 19 21:58:34.795 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  29  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:58:34.744 2009  to  Thu Mar 19 21:58:34.744 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  30  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:58:35.644 2009  to  Thu Mar 19 21:58:35.644 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:58:35.695 2009  to  Thu Mar 19 21:58:35.695 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 19 22:28:14.371 2009  to  Thu Mar 19 22:28:14.371 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  33  FAILED    PMC        thermal.badReceive                                            Thu Mar 19 22:28:14.476 2009  to  Thu Mar 19 22:28:14.476 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  34  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 19 22:28:14.424 2009  to  Thu Mar 19 22:28:14.424 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

  35  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 19 22:35:46.234 2009  to  Thu Mar 19 22:35:46.234 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  36  FAILED    PMC        thermal.badReceive                                            Thu Mar 19 22:35:46.341 2009  to  Thu Mar 19 22:35:46.341 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  37  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 19 22:35:46.287 2009  to  Thu Mar 19 22:35:46.287 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  38  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 22:45:18.799 2009  to  Thu Mar 19 22:45:18.799 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Thu Mar 19 22:45:18.851 2009  to  Thu Mar 19 22:45:18.851 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:00:52.479 2009  to  Thu Mar 19 23:00:52.479 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:00:52.532 2009  to  Thu Mar 19 23:00:52.532 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  42  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:28:14.931 2009  to  Thu Mar 19 23:28:14.931 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  43  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:28:14.984 2009  to  Thu Mar 19 23:28:14.984 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  44  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:41:24.788 2009  to  Thu Mar 19 23:41:24.788 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:41:24.840 2009  to  Thu Mar 19 23:41:24.840 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:47:33.909 2009  to  Thu Mar 19 23:47:33.909 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:47:33.856 2009  to  Thu Mar 19 23:47:33.856 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:50:24.383 2009  to  Thu Mar 19 23:50:24.383 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:50:24.332 2009  to  Thu Mar 19 23:50:24.332 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

  50  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:55:47.756 2009  to  Thu Mar 19 23:55:47.756 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:55:47.808 2009  to  Thu Mar 19 23:55:47.808 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:00:54.635 2009  to  Fri Mar 20 00:00:54.635 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:00:54.688 2009  to  Fri Mar 20 00:00:54.688 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:51:21.478 2009  to  Fri Mar 20 00:51:21.478 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:51:21.530 2009  to  Fri Mar 20 00:51:21.530 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  56  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:52:37.266 2009  to  Fri Mar 20 00:52:37.266 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:52:37.318 2009  to  Fri Mar 20 00:52:37.318 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:54:55.797 2009  to  Fri Mar 20 00:54:55.797 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:54:55.745 2009  to  Fri Mar 20 00:54:55.745 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:57:50.719 2009  to  Fri Mar 20 00:57:50.719 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:57:50.770 2009  to  Fri Mar 20 00:57:50.770 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  62  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 01:13:59.773 2009  to  Fri Mar 20 01:14:10.843 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 01:54:12.076 2009  to  Fri Mar 20 01:54:12.076 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Fri Mar 20 01:54:12.129 2009  to  Fri Mar 20 01:54:12.129 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  65  FAILED    PMC        VxInterface.close                                             Fri Mar 20 02:38:22.328 2009  to  Fri Mar 20 02:38:22.328 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 02:38:22.274 2009  to  Fri Mar 20 02:38:22.274 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 03:02:28.082 2009  to  Fri Mar 20 03:02:53.179 2009   ( 25.10) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 03:22:56.549 2009  to  Fri Mar 20 03:22:56.549 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  69  FAILED    PMC        thermal.badReceive                                            Fri Mar 20 03:22:56.657 2009  to  Fri Mar 20 03:22:56.657 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  70  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 20 03:22:56.603 2009  to  Fri Mar 20 03:22:56.603 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  71  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 04:35:03.360 2009  to  Fri Mar 20 04:35:11.428 2009   (  8.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  72  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 04:38:22.495 2009  to  Fri Mar 20 04:38:27.556 2009   (  5.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  73  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:03.979 2009  to  Fri Mar 20 05:10:03.979 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  74  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 20 05:10:04.031 2009  to  Fri Mar 20 05:10:04.031 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

  75  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:04.386 2009  to  Fri Mar 20 05:10:04.386 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  76  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:04.741 2009  to  Fri Mar 20 05:10:04.741 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  77  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:05.095 2009  to  Fri Mar 20 05:10:05.095 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  78  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 05:25:42.711 2009  to  Fri Mar 20 05:25:51.775 2009   (  9.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 05:26:15.068 2009  to  Fri Mar 20 05:26:21.135 2009   (  6.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.62    8.89    0.41   43.09    98.5 %        397        391          6           
                                                                       4.52    8.79    0.41   43.09
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         26         26                      
                                                                       0.00    0.05    0.05    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    6.48    6.20    2.39   84.60    99.5 %        599        596          3           
                                                                       6.50    6.20    2.39   84.60
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.07    0.48    0.44    0.53     0.0 %          2                     2           
                                                                                                   
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.62    9.00    0.52   43.20    98.5 %        397        391          6           
                                                                       4.52    8.90    0.52   43.20
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    4.57    8.70    0.19   42.88    98.6 %        418        412          6           
                                                                       4.48    8.61    0.19   42.88
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    5.74    6.34    0.00   84.38    98.9 %       1004        993         11           
                                                                       5.73    6.33    2.18   84.38
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.25    3.07    2.19    5.19   100.0 %          8          8                      
                                                                       1.25    3.07    2.19    5.19
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.10    0.07    0.60   100.0 %        695        695                      
                                                                       0.04    0.10    0.07    0.60
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.16    0.20    0.08    0.38    33.3 %          3          1          2           
                                                                       0.00    0.38    0.38    0.38
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    9.09   13.23    2.55   23.58    66.7 %          6          4          2           
                                                                       6.57   18.07    8.54   23.58
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    6.48    6.09    2.29   84.49    99.5 %        599        596          3           
                                                                       6.50    6.08    2.29   84.49
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %         21         21                      
                                                                       0.00    0.06    0.06    0.06
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    8.30    8.30    8.30   100.0 %          1          1                      
                                                                       0.00    8.30    8.30    8.30
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.11   100.0 %        418        418                      
                                                                       0.00    0.05    0.05    0.11
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    0.00   43.89   43.89   43.89   100.0 %          1          1                      
                                                                       0.00   43.89   43.89   43.89
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.01    0.07    0.07    0.08   100.0 %          2          2                      
                                                                       0.01    0.07    0.07    0.08
     secondaryMirror.command.revert . . . . . . . . . . . . . . . .    0.00   44.00   44.00   44.00   100.0 %          1          1                      
                                                                       0.00   44.00   44.00   44.00
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.02    0.07    0.06    0.09   100.0 %          2          2                      
                                                                       0.02    0.07    0.06    0.09

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                402           

PSF Events of Interest

   1  FAILED    PSF        command.setNewInstrument                                      Thu Mar 19 18:23:39.822 2009  to  Thu Mar 19 18:23:40.355 2009   (  0.53) secs
                     left PSF SetNewInstrument started for instrument LBC, focal station prime
                     right PSF SetNewInstrument failed for instrument LBC, focal station prime

   2  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu Mar 19 18:23:39.874 2009  to  Thu Mar 19 18:23:40.023 2009   (  0.15) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   3  FAILED    PSF        command.setNewInstrument                                      Thu Mar 19 18:23:40.318 2009  to  Thu Mar 19 18:23:40.754 2009   (  0.44) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

   4  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu Mar 19 18:23:40.371 2009  to  Thu Mar 19 18:23:40.453 2009   (  0.08) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

   5  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:00.262 2009  to  Thu Mar 19 18:50:10.078 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:00.280 2009  to  Thu Mar 19 18:50:11.580 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  FAILED    PSF        primaryMirror.command.revert                                  Thu Mar 19 18:50:05.777 2009  to  Thu Mar 19 18:50:10.320 2009   (  4.54) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   8  FAILED    PSF        primaryMirror.command.revert                                  Thu Mar 19 18:50:09.273 2009  to  Thu Mar 19 18:50:11.821 2009   (  2.55) secs
                     right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:10.078 2009  to  Thu Mar 19 18:50:10.264 2009   (  0.19) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:11.580 2009  to  Thu Mar 19 18:50:11.764 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:36.557 2009  to  Thu Mar 19 18:50:36.557 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  12  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:51:24.612 2009  to  Thu Mar 19 18:51:24.612 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  13  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 19:47:13.310 2009  to  Thu Mar 19 19:47:13.310 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.2406111e-03 -4.3308735e-04 5.4347515e-04 -1.5396118e-01 5.9013367e-03 3.2849312e-02

  14  FAILED    PSF        command.setZernikes                                           Thu Mar 19 20:22:00.032 2009  to  Thu Mar 19 20:22:11.061 2009   ( 11.03) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  15  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 20:22:00.085 2009  to  Thu Mar 19 20:22:10.963 2009   ( 10.88) secs
                     right PSF ApplyZernikes failed

  16  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 20:22:00.249 2009  to  Thu Mar 19 20:22:10.907 2009   ( 10.66) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 20:22:03.654 2009  to  Thu Mar 19 20:22:10.850 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 20:34:04.579 2009  to  Thu Mar 19 20:34:14.379 2009   (  9.80) secs
                     right PSF ApplyZernikes failed

  19  FAILED    PSF        command.setZernikes                                           Thu Mar 19 20:34:04.527 2009  to  Thu Mar 19 20:34:14.436 2009   (  9.91) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  20  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 20:34:04.741 2009  to  Thu Mar 19 20:34:14.320 2009   (  9.58) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 20:34:08.074 2009  to  Thu Mar 19 20:34:14.265 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        command.setZernikes                                           Thu Mar 19 21:31:30.757 2009  to  Thu Mar 19 21:31:44.639 2009   ( 13.88) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  23  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 21:31:30.808 2009  to  Thu Mar 19 21:31:44.583 2009   ( 13.77) secs
                     right PSF ApplyZernikes failed

  24  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 21:31:30.970 2009  to  Thu Mar 19 21:31:44.527 2009   ( 13.56) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 21:31:34.269 2009  to  Thu Mar 19 21:31:44.471 2009   ( 10.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  26  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 21:34:31.061 2009  to  Thu Mar 19 21:34:31.061 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1457672e-03 3.7199259e-04 -8.5887313e-04 1.5599489e-01 -1.3256073e-02 -4.9012184e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:46.621 2009  to  Thu Mar 19 22:37:46.621 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:46.877 2009  to  Thu Mar 19 22:37:46.877 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:47.133 2009  to  Thu Mar 19 22:37:47.133 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:48.809 2009  to  Thu Mar 19 22:37:48.809 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:49.674 2009  to  Thu Mar 19 22:37:49.674 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6683340e-03 5.3837895e-04 -7.0366263e-04 1.5987396e-01 -7.1510315e-02 -9.3309164e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:49.930 2009  to  Thu Mar 19 22:37:49.930 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6683340e-03 5.3837895e-04 -7.0366263e-04 1.5987396e-01 -7.1510315e-02 -9.3309164e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:53.020 2009  to  Thu Mar 19 22:37:53.020 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:53.274 2009  to  Thu Mar 19 22:37:53.274 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:07.666 2009  to  Thu Mar 19 22:38:07.666 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:07.921 2009  to  Thu Mar 19 22:38:07.921 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:31.493 2009  to  Thu Mar 19 22:38:31.493 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:31.747 2009  to  Thu Mar 19 22:38:31.747 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:33.819 2009  to  Thu Mar 19 22:38:33.819 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:34.074 2009  to  Thu Mar 19 22:38:34.074 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:34.327 2009  to  Thu Mar 19 22:38:34.327 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:38.419 2009  to  Thu Mar 19 22:38:38.419 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8705130e-03 2.5373697e-04 -5.0759315e-04 1.5270615e-01 -1.5319824e-02 -1.0400701e-01

  43  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:42.713 2009  to  Thu Mar 19 22:38:42.713 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.392 2009  to  Thu Mar 19 22:38:45.392 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.646 2009  to  Thu Mar 19 22:38:45.646 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.901 2009  to  Thu Mar 19 22:38:45.901 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:47.166 2009  to  Thu Mar 19 22:38:47.166 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:50.869 2009  to  Thu Mar 19 22:38:50.869 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5065670e-03 2.4271011e-04 -8.8554621e-04 1.5330124e-01 -4.9753189e-02 -1.0361266e-01

  49  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:51.124 2009  to  Thu Mar 19 22:38:51.124 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5065670e-03 2.4271011e-04 -8.8554621e-04 1.5330124e-01 -4.9753189e-02 -1.0361266e-01

  50  FAILED    PSF        command.setZernikes                                           Fri Mar 20 01:13:56.870 2009  to  Fri Mar 20 01:14:11.076 2009   ( 14.21) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  51  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 01:13:56.923 2009  to  Fri Mar 20 01:14:11.020 2009   ( 14.10) secs
                     right PSF ApplyZernikes failed

  52  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 01:13:57.085 2009  to  Fri Mar 20 01:14:10.964 2009   ( 13.88) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 01:13:59.709 2009  to  Fri Mar 20 01:14:10.908 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  54  FAILED    PSF        command.setZernikes                                           Fri Mar 20 03:02:24.517 2009  to  Fri Mar 20 03:02:53.414 2009   ( 28.90) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  55  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 03:02:24.600 2009  to  Fri Mar 20 03:02:53.358 2009   ( 28.76) secs
                     right PSF ApplyZernikes failed

  56  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 03:02:24.763 2009  to  Fri Mar 20 03:02:53.301 2009   ( 28.54) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  57  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 03:02:28.021 2009  to  Fri Mar 20 03:02:53.245 2009   ( 25.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 04:35:03.187 2009  to  Fri Mar 20 04:35:11.605 2009   (  8.42) secs
                     right PSF SetInstrumentOffsets failed

  59  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 04:35:03.240 2009  to  Fri Mar 20 04:35:11.549 2009   (  8.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 04:35:03.293 2009  to  Fri Mar 20 04:35:11.493 2009   (  8.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 04:38:22.329 2009  to  Fri Mar 20 04:38:27.734 2009   (  5.41) secs
                     right PSF SetInstrumentOffsets failed

  62  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 04:38:22.382 2009  to  Fri Mar 20 04:38:27.678 2009   (  5.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  63  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 04:38:22.434 2009  to  Fri Mar 20 04:38:27.622 2009   (  5.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 05:25:39.249 2009  to  Fri Mar 20 05:25:51.955 2009   ( 12.71) secs
                     right PSF ApplyZernikes failed

  65  FAILED    PSF        command.setZernikes                                           Fri Mar 20 05:25:39.197 2009  to  Fri Mar 20 05:25:52.014 2009   ( 12.82) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  66  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 05:25:39.411 2009  to  Fri Mar 20 05:25:51.899 2009   ( 12.49) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 05:25:42.652 2009  to  Fri Mar 20 05:25:51.842 2009   (  9.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 05:26:14.902 2009  to  Fri Mar 20 05:26:21.315 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

  69  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 05:26:15.006 2009  to  Fri Mar 20 05:26:21.204 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  70  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 05:26:14.954 2009  to  Fri Mar 20 05:26:21.259 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:00.398 2009  to  Thu Mar 19 18:00:00.398 2009   (  0.00) secs
                     EL bad poly no. 105003: BAD Poly: EL = -1.154589e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:03.399 2009  to  Thu Mar 19 18:00:03.399 2009   (  0.00) secs
                     EL bad poly no. 105053: BAD Poly: EL = -1.154945e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:06.438 2009  to  Thu Mar 19 18:00:06.438 2009   (  0.00) secs
                     EL bad poly no. 105109: BAD Poly: EL = -1.155307e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:09.495 2009  to  Thu Mar 19 18:00:09.495 2009   (  0.00) secs
                     EL bad poly no. 105162: BAD Poly: EL = -1.155670e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:12.498 2009  to  Thu Mar 19 18:00:12.498 2009   (  0.00) secs
                     EL bad poly no. 105214: BAD Poly: EL = -1.156027e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:15.556 2009  to  Thu Mar 19 18:00:15.556 2009   (  0.00) secs
                     EL bad poly no. 105272: BAD Poly: EL = -1.156390e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:18.569 2009  to  Thu Mar 19 18:00:18.569 2009   (  0.00) secs
                     EL bad poly no. 105328: BAD Poly: EL = -1.156747e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:21.578 2009  to  Thu Mar 19 18:00:21.578 2009   (  0.00) secs
                     EL bad poly no. 105382: BAD Poly: EL = -1.157104e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:24.624 2009  to  Thu Mar 19 18:00:24.624 2009   (  0.00) secs
                     EL bad poly no. 105438: BAD Poly: EL = -1.157464e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:27.629 2009  to  Thu Mar 19 18:00:27.629 2009   (  0.00) secs
                     EL bad poly no. 105493: BAD Poly: EL = -1.157820e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:30.645 2009  to  Thu Mar 19 18:00:30.645 2009   (  0.00) secs
                     EL bad poly no. 105548: BAD Poly: EL = -1.158176e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:33.682 2009  to  Thu Mar 19 18:00:33.682 2009   (  0.00) secs
                     EL bad poly no. 105604: BAD Poly: EL = -1.158536e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:36.691 2009  to  Thu Mar 19 18:00:36.691 2009   (  0.00) secs
                     EL bad poly no. 105661: BAD Poly: EL = -1.158891e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:39.721 2009  to  Thu Mar 19 18:00:39.721 2009   (  0.00) secs
                     EL bad poly no. 105716: BAD Poly: EL = -1.159248e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:42.754 2009  to  Thu Mar 19 18:00:42.754 2009   (  0.00) secs
                     EL bad poly no. 105771: BAD Poly: EL = -1.159606e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:45.800 2009  to  Thu Mar 19 18:00:45.800 2009   (  0.00) secs
                     EL bad poly no. 105826: BAD Poly: EL = -1.159965e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:48.829 2009  to  Thu Mar 19 18:00:48.829 2009   (  0.00) secs
                     EL bad poly no. 105882: BAD Poly: EL = -1.160322e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:51.873 2009  to  Thu Mar 19 18:00:51.873 2009   (  0.00) secs
                     EL bad poly no. 105937: BAD Poly: EL = -1.160680e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:54.890 2009  to  Thu Mar 19 18:00:54.890 2009   (  0.00) secs
                     EL bad poly no. 105992: BAD Poly: EL = -1.161035e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:00:57.892 2009  to  Thu Mar 19 18:00:57.892 2009   (  0.00) secs
                     EL bad poly no. 106047: BAD Poly: EL = -1.161387e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:00.909 2009  to  Thu Mar 19 18:01:00.909 2009   (  0.00) secs
                     EL bad poly no. 106099: BAD Poly: EL = -1.161741e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:03.941 2009  to  Thu Mar 19 18:01:03.941 2009   (  0.00) secs
                     EL bad poly no. 106149: BAD Poly: EL = -1.162097e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:06.951 2009  to  Thu Mar 19 18:01:06.951 2009   (  0.00) secs
                     EL bad poly no. 106203: BAD Poly: EL = -1.162450e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:09.966 2009  to  Thu Mar 19 18:01:09.966 2009   (  0.00) secs
                     EL bad poly no. 106257: BAD Poly: EL = -1.162803e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Mar 19 18:01:13.016 2009  to  Thu Mar 19 18:01:13.016 2009   (  0.00) secs
                     EL bad poly no. 106312: BAD Poly: EL = -1.163160e-01 rad. Too low.

  26  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Mar 19 18:23:38.271 2009  to  Thu Mar 19 18:23:41.035 2009   (  2.76) secs
                     IIF TCS authorize alert for left LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for left LBC at prime focus: left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for left LBC at prime focus: left PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for left LBC at prime focus

  27  FAILED    IIF GUI    IIFCommand.authorize                                          Thu Mar 19 18:23:38.335 2009  to  Thu Mar 19 18:23:40.629 2009   (  2.29) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize alert for right LBC at prime focus: right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit
                     IIF TCS authorize alert for right LBC at prime focus: right PSF SetNewInstrument failed for instrument LBC, focal station prime
                     IIF TCS authorize command failed for right LBC at prime focus

  28  SEQERROR  PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.501 2009  to  Thu Mar 19 18:23:38.649 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  29  FAILED    PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.649 2009  to  Thu Mar 19 18:23:38.766 2009   (  0.12) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  30  SEQERROR  PCS        telescope.command.stopTracking                                Thu Mar 19 18:23:38.899 2009  to  Thu Mar 19 18:23:38.899 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  31  FAILED    PSF        command.setNewInstrument                                      Thu Mar 19 18:23:39.822 2009  to  Thu Mar 19 18:23:40.355 2009   (  0.53) secs
                     left PSF SetNewInstrument started for instrument LBC, focal station prime
                     right PSF SetNewInstrument failed for instrument LBC, focal station prime

  32  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu Mar 19 18:23:39.874 2009  to  Thu Mar 19 18:23:40.023 2009   (  0.15) secs
                     right PSF primary mirror initMirrorCollimation started
                     right PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  33  FAILED    PSF        command.setNewInstrument                                      Thu Mar 19 18:23:40.318 2009  to  Thu Mar 19 18:23:40.754 2009   (  0.44) secs
                     left PSF tertiary mirror initMirrorCollimation started
                     left PSF SetNewInstrument failed for instrument LBC, focal station prime

  34  FAILED    PSF        primaryMirror.command.initMirrorCollimation                   Thu Mar 19 18:23:40.371 2009  to  Thu Mar 19 18:23:40.453 2009   (  0.08) secs
                     left PSF primary mirror initMirrorCollimation started
                     left PSF primary mirror initMirrorCollimation failed because Primary mirror collimation reached limit

  35  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Thu Mar 19 18:23:42.042 2009  to  Thu Mar 19 18:23:42.042 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:23:57.744 2009  to  Thu Mar 19 18:23:57.744 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  37  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:24:25.402 2009  to  Thu Mar 19 18:24:25.402 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  38  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:24:29.185 2009  to  Thu Mar 19 18:24:29.185 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:24:34.807 2009  to  Thu Mar 19 18:24:34.807 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:25:27.111 2009  to  Thu Mar 19 18:25:27.111 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  41  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Thu Mar 19 18:25:36.511 2009  to  Thu Mar 19 18:25:36.511 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  42  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnTimeOut                                   Thu Mar 19 18:25:51.959 2009  to  Thu Mar 19 18:25:51.959 2009   (  0.00) secs
                     Timed out waiting for power amplifiers to turn on.

  43  FAILED    IIF        command.preset.(TRACK)                                        Thu Mar 19 18:28:50.664 2009  to  Thu Mar 19 18:29:04.469 2009   ( 13.81) secs
                     IIF Preset command wait for elevation started for both LBC
                     IIF Preset alert for both LBC mode TRACK: IIF Preset command aborted for both LBC mode TRACK from IIF
                     IIF Preset command failed for both LBC mode TRACK from IIF

  44  SEQERROR  IIF        command.preset.elevationWait                                  Thu Mar 19 18:28:52.287 2009  to  Thu Mar 19 19:30:49.237 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for both LBC

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.unexpectedVelMode                               Thu Mar 19 18:29:10.158 2009  to  Thu Mar 19 18:29:10.158 2009   (  0.00) secs
                     The AZ Servo DSP changed to Velocity mode unexpectedly.

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Mar 19 18:29:11.199 2009  to  Thu Mar 19 18:29:11.199 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Mar 19 18:29:11.199 2009  to  Thu Mar 19 18:29:11.199 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  48  FAILED    IIF        command.offset                                                Thu Mar 19 18:30:48.538 2009  to  Thu Mar 19 18:35:49.678 2009   (301.14) secs
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  49  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 19 18:30:48.956 2009  to  Thu Mar 19 18:36:18.428 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  50  FAILED    IIF        command.offset                                                Thu Mar 19 18:36:18.094 2009  to  Thu Mar 19 18:41:19.156 2009   (301.06) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC
                     IIF Offset alert for both LBC: IIF Offset command mount timed out in 300 seconds for both LBC from IIF
                     IIF Offset command failed for both LBC from IIF

  51  SEQERROR  IIF        command.offset.telescopeWait                                  Thu Mar 19 18:36:18.428 2009  to  Thu Mar 19 18:54:16.321 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Offset command wait for telescope started for both LBC

  52  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:00.262 2009  to  Thu Mar 19 18:50:10.078 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:00.280 2009  to  Thu Mar 19 18:50:11.580 2009   (  0.00) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:00.326 2009  to  Thu Mar 19 18:50:10.142 2009   (  0.00) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:00.372 2009  to  Thu Mar 19 18:50:11.645 2009   (  0.00) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  56  FAILED    PSF        primaryMirror.command.revert                                  Thu Mar 19 18:50:05.777 2009  to  Thu Mar 19 18:50:10.320 2009   (  4.54) secs
                     left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  57  FAILED    PSF        primaryMirror.command.revert                                  Thu Mar 19 18:50:09.273 2009  to  Thu Mar 19 18:50:11.821 2009   (  2.55) secs
                     right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  58  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:10.142 2009  to  Thu Mar 19 18:50:10.195 2009   (  0.05) secs
                    Started event but no Complete event
                     left PMC Mirror GoToPositionAbs Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  59  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:10.078 2009  to  Thu Mar 19 18:50:10.264 2009   (  0.19) secs
                    Started event but no Complete event
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:11.580 2009  to  Thu Mar 19 18:50:11.764 2009   (  0.18) secs
                    Started event but no Complete event
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:11.645 2009  to  Thu Mar 19 18:50:11.697 2009   (  0.05) secs
                    Started event but no Complete event
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 18:50:35.345 2009  to  Thu Mar 19 18:50:35.345 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Thu Mar 19 18:50:35.398 2009  to  Thu Mar 19 18:50:35.398 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  64  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:50:36.492 2009  to  Thu Mar 19 18:50:36.492 2009   (  0.00) secs
                    Complete event but no Started event
                     right PMC Mirror GoToPositionAbs Command Complete

  65  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:50:36.557 2009  to  Thu Mar 19 18:50:36.557 2009   (  0.00) secs
                    Complete event but no Started event
                     right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 18:51:24.544 2009  to  Thu Mar 19 18:51:24.544 2009   (  0.00) secs
                    Complete event but no Started event
                     left PMC Mirror GoToPositionAbs Command Complete

  67  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 18:51:24.612 2009  to  Thu Mar 19 18:51:24.612 2009   (  0.00) secs
                    Complete event but no Started event
                     left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  68  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:11:45.853 2009  to  Thu Mar 19 19:11:45.853 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  69  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:11:45.962 2009  to  Thu Mar 19 19:11:45.962 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:42:27.571 2009  to  Thu Mar 19 19:42:27.571 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:42:27.624 2009  to  Thu Mar 19 19:42:27.624 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  72  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 19:47:13.310 2009  to  Thu Mar 19 19:47:13.310 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: 1.2406111e-03 -4.3308735e-04 5.4347515e-04 -1.5396118e-01 5.9013367e-03 3.2849312e-02

  73  FAILED    PMC        VxInterface.close                                             Thu Mar 19 19:56:09.504 2009  to  Thu Mar 19 19:56:09.504 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 19:56:09.452 2009  to  Thu Mar 19 19:56:09.452 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  75  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 20:21:59.959 2009  to  Thu Mar 19 20:22:11.177 2009   ( 11.22) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  76  FAILED    PSF        command.setZernikes                                           Thu Mar 19 20:22:00.032 2009  to  Thu Mar 19 20:22:11.061 2009   ( 11.03) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  77  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 20:22:00.085 2009  to  Thu Mar 19 20:22:10.963 2009   ( 10.88) secs
                     right PSF ApplyZernikes failed

  78  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 20:22:00.249 2009  to  Thu Mar 19 20:22:10.907 2009   ( 10.66) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 20:22:03.654 2009  to  Thu Mar 19 20:22:10.850 2009   (  7.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  80  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 20:22:03.717 2009  to  Thu Mar 19 20:22:10.783 2009   (  7.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  81  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 20:34:04.451 2009  to  Thu Mar 19 20:34:14.553 2009   ( 10.10) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  82  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 20:34:04.579 2009  to  Thu Mar 19 20:34:14.379 2009   (  9.80) secs
                     right PSF ApplyZernikes failed

  83  FAILED    PSF        command.setZernikes                                           Thu Mar 19 20:34:04.527 2009  to  Thu Mar 19 20:34:14.436 2009   (  9.91) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  84  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 20:34:04.741 2009  to  Thu Mar 19 20:34:14.320 2009   (  9.58) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 20:34:08.135 2009  to  Thu Mar 19 20:34:14.198 2009   (  6.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  86  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 20:34:08.074 2009  to  Thu Mar 19 20:34:14.265 2009   (  6.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:04:01.877 2009  to  Thu Mar 19 21:04:01.877 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  88  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:04:01.825 2009  to  Thu Mar 19 21:04:01.825 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  89  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:21:54.030 2009  to  Thu Mar 19 21:21:54.030 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:21:53.976 2009  to  Thu Mar 19 21:21:53.976 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  91  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:21:55.927 2009  to  Thu Mar 19 21:21:55.927 2009   (  0.00) secs
                     right PMC Actuator closing network connection

  92  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:21:55.875 2009  to  Thu Mar 19 21:21:55.875 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

  93  FAILED    PSF        command.setZernikes                                           Thu Mar 19 21:31:30.757 2009  to  Thu Mar 19 21:31:44.639 2009   ( 13.88) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

  94  FAILED    IIF        command.sendWavefront                                         Thu Mar 19 21:31:30.684 2009  to  Thu Mar 19 21:31:44.758 2009   ( 14.07) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

  95  FAILED    PSF        command.applyZernikes                                         Thu Mar 19 21:31:30.808 2009  to  Thu Mar 19 21:31:44.583 2009   ( 13.77) secs
                     right PSF ApplyZernikes failed

  96  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Mar 19 21:31:30.970 2009  to  Thu Mar 19 21:31:44.527 2009   ( 13.56) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Mar 19 21:31:34.269 2009  to  Thu Mar 19 21:31:44.471 2009   ( 10.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  98  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Mar 19 21:31:34.332 2009  to  Thu Mar 19 21:31:44.401 2009   ( 10.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  99  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 21:34:31.061 2009  to  Thu Mar 19 21:34:31.061 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1457672e-03 3.7199259e-04 -8.5887313e-04 1.5599489e-01 -1.3256073e-02 -4.9012184e-02

 100  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:37:36.134 2009  to  Thu Mar 19 21:37:36.134 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 101  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:37:36.185 2009  to  Thu Mar 19 21:37:36.185 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:42:25.574 2009  to  Thu Mar 19 21:42:25.574 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 103  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:42:25.627 2009  to  Thu Mar 19 21:42:25.627 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 104  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:58:34.795 2009  to  Thu Mar 19 21:58:34.795 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 105  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:58:34.744 2009  to  Thu Mar 19 21:58:34.744 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 106  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 21:58:35.644 2009  to  Thu Mar 19 21:58:35.644 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 107  FAILED    PMC        VxInterface.close                                             Thu Mar 19 21:58:35.695 2009  to  Thu Mar 19 21:58:35.695 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 108  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 19 22:28:14.371 2009  to  Thu Mar 19 22:28:14.371 2009   (  0.00) secs
                     right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 109  FAILED    PMC        thermal.badReceive                                            Thu Mar 19 22:28:14.476 2009  to  Thu Mar 19 22:28:14.476 2009   (  0.00) secs
                     right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 110  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 19 22:28:14.424 2009  to  Thu Mar 19 22:28:14.424 2009   (  0.00) secs
                     right PMC Thermal packet read error: 5002

 111  FAILED    PMC        VxInterface.selectTimeout                                     Thu Mar 19 22:35:46.234 2009  to  Thu Mar 19 22:35:46.234 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 112  FAILED    PMC        thermal.badReceive                                            Thu Mar 19 22:35:46.341 2009  to  Thu Mar 19 22:35:46.341 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 113  FAILED    PMC        VxInterface.packetReadError                                   Thu Mar 19 22:35:46.287 2009  to  Thu Mar 19 22:35:46.287 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 114  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:46.621 2009  to  Thu Mar 19 22:37:46.621 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 115  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:46.877 2009  to  Thu Mar 19 22:37:46.877 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 116  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:47.133 2009  to  Thu Mar 19 22:37:47.133 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 117  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:48.809 2009  to  Thu Mar 19 22:37:48.809 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 118  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:49.674 2009  to  Thu Mar 19 22:37:49.674 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6683340e-03 5.3837895e-04 -7.0366263e-04 1.5987396e-01 -7.1510315e-02 -9.3309164e-02

 119  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:49.930 2009  to  Thu Mar 19 22:37:49.930 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.6683340e-03 5.3837895e-04 -7.0366263e-04 1.5987396e-01 -7.1510315e-02 -9.3309164e-02

 120  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:53.020 2009  to  Thu Mar 19 22:37:53.020 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 121  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:37:53.274 2009  to  Thu Mar 19 22:37:53.274 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 122  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:07.666 2009  to  Thu Mar 19 22:38:07.666 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 123  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:07.921 2009  to  Thu Mar 19 22:38:07.921 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 124  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:31.493 2009  to  Thu Mar 19 22:38:31.493 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 125  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:31.747 2009  to  Thu Mar 19 22:38:31.747 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 126  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:33.819 2009  to  Thu Mar 19 22:38:33.819 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 127  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:34.074 2009  to  Thu Mar 19 22:38:34.074 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 128  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:34.327 2009  to  Thu Mar 19 22:38:34.327 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 129  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:38.419 2009  to  Thu Mar 19 22:38:38.419 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.8705130e-03 2.5373697e-04 -5.0759315e-04 1.5270615e-01 -1.5319824e-02 -1.0400701e-01

 130  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:42.713 2009  to  Thu Mar 19 22:38:42.713 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.0323396e-03 5.4940581e-04 -3.2570958e-04 1.5927887e-01 -3.7076950e-02 -9.3703508e-02

 131  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.392 2009  to  Thu Mar 19 22:38:45.392 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 132  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.646 2009  to  Thu Mar 19 22:38:45.646 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 133  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:45.901 2009  to  Thu Mar 19 22:38:45.901 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 134  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:47.166 2009  to  Thu Mar 19 22:38:47.166 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -2.1932721e-03 2.3677945e-04 -7.0510805e-04 1.5299511e-01 -5.9942245e-02 -7.2211266e-02

 135  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:50.869 2009  to  Thu Mar 19 22:38:50.869 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5065670e-03 2.4271011e-04 -8.8554621e-04 1.5330124e-01 -4.9753189e-02 -1.0361266e-01

 136  FAILED    PSF        primaryMirror.positionError                                   Thu Mar 19 22:38:51.124 2009  to  Thu Mar 19 22:38:51.124 2009   (  0.00) secs
                     right PSF primary mirror collimation position error: -1.5065670e-03 2.4271011e-04 -8.8554621e-04 1.5330124e-01 -4.9753189e-02 -1.0361266e-01

 137  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 22:45:18.799 2009  to  Thu Mar 19 22:45:18.799 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 138  FAILED    PMC        VxInterface.close                                             Thu Mar 19 22:45:18.851 2009  to  Thu Mar 19 22:45:18.851 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 139  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:00:52.479 2009  to  Thu Mar 19 23:00:52.479 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 140  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:00:52.532 2009  to  Thu Mar 19 23:00:52.532 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 141  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:28:14.931 2009  to  Thu Mar 19 23:28:14.931 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 142  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:28:14.984 2009  to  Thu Mar 19 23:28:14.984 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 143  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:41:24.788 2009  to  Thu Mar 19 23:41:24.788 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 144  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:41:24.840 2009  to  Thu Mar 19 23:41:24.840 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 145  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:47:33.909 2009  to  Thu Mar 19 23:47:33.909 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:47:33.856 2009  to  Thu Mar 19 23:47:33.856 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 147  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:50:24.383 2009  to  Thu Mar 19 23:50:24.383 2009   (  0.00) secs
                     right PMC ServoLoop closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:50:24.332 2009  to  Thu Mar 19 23:50:24.332 2009   (  0.00) secs
                     right PMC ServoLoop length error: expected 544, got 96

 149  FAILED    PMC        VxInterface.lengthError                                       Thu Mar 19 23:55:47.756 2009  to  Thu Mar 19 23:55:47.756 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 150  FAILED    PMC        VxInterface.close                                             Thu Mar 19 23:55:47.808 2009  to  Thu Mar 19 23:55:47.808 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 151  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:00:54.635 2009  to  Fri Mar 20 00:00:54.635 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 152  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:00:54.688 2009  to  Fri Mar 20 00:00:54.688 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 153  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:51:21.478 2009  to  Fri Mar 20 00:51:21.478 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 154  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:51:21.530 2009  to  Fri Mar 20 00:51:21.530 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 155  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:52:37.266 2009  to  Fri Mar 20 00:52:37.266 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 156  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:52:37.318 2009  to  Fri Mar 20 00:52:37.318 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 157  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:54:55.797 2009  to  Fri Mar 20 00:54:55.797 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 158  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:54:55.745 2009  to  Fri Mar 20 00:54:55.745 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 159  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 00:57:50.719 2009  to  Fri Mar 20 00:57:50.719 2009   (  0.00) secs
                     right PMC Actuator length error: expected 152, got 96

 160  FAILED    PMC        VxInterface.close                                             Fri Mar 20 00:57:50.770 2009  to  Fri Mar 20 00:57:50.770 2009   (  0.00) secs
                     right PMC Actuator closing network connection

 161  FAILED    PSF        command.setZernikes                                           Fri Mar 20 01:13:56.870 2009  to  Fri Mar 20 01:14:11.076 2009   ( 14.21) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 162  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 01:13:56.801 2009  to  Fri Mar 20 01:14:11.193 2009   ( 14.39) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 163  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 01:13:56.923 2009  to  Fri Mar 20 01:14:11.020 2009   ( 14.10) secs
                     right PSF ApplyZernikes failed

 164  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 01:13:57.085 2009  to  Fri Mar 20 01:14:10.964 2009   ( 13.88) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 165  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 01:13:59.709 2009  to  Fri Mar 20 01:14:10.908 2009   ( 11.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 166  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 01:13:59.773 2009  to  Fri Mar 20 01:14:10.843 2009   ( 11.07) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 167  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 01:54:12.076 2009  to  Fri Mar 20 01:54:12.076 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 168  FAILED    PMC        VxInterface.close                                             Fri Mar 20 01:54:12.129 2009  to  Fri Mar 20 01:54:12.129 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 169  FAILED    PMC        VxInterface.close                                             Fri Mar 20 02:38:22.328 2009  to  Fri Mar 20 02:38:22.328 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 170  FAILED    PMC        VxInterface.lengthError                                       Fri Mar 20 02:38:22.274 2009  to  Fri Mar 20 02:38:22.274 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 171  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 03:02:24.446 2009  to  Fri Mar 20 03:02:53.534 2009   ( 29.09) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 172  FAILED    PSF        command.setZernikes                                           Fri Mar 20 03:02:24.517 2009  to  Fri Mar 20 03:02:53.414 2009   ( 28.90) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 173  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 03:02:24.600 2009  to  Fri Mar 20 03:02:53.358 2009   ( 28.76) secs
                     right PSF ApplyZernikes failed

 174  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 03:02:24.763 2009  to  Fri Mar 20 03:02:53.301 2009   ( 28.54) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 175  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 03:02:28.021 2009  to  Fri Mar 20 03:02:53.245 2009   ( 25.22) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 176  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 03:02:28.082 2009  to  Fri Mar 20 03:02:53.179 2009   ( 25.10) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 177  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 03:22:56.549 2009  to  Fri Mar 20 03:22:56.549 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 178  FAILED    PMC        thermal.badReceive                                            Fri Mar 20 03:22:56.657 2009  to  Fri Mar 20 03:22:56.657 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 179  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 20 03:22:56.603 2009  to  Fri Mar 20 03:22:56.603 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 180  FAILED    IIF        command.moveFocus                                             Fri Mar 20 04:35:03.120 2009  to  Fri Mar 20 04:35:11.772 2009   (  8.65) secs
                     IIF MoveFocus command started for right LBC for 2.000000000000000e-01
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 2.000000000000000e-01

 181  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 04:35:03.187 2009  to  Fri Mar 20 04:35:11.605 2009   (  8.42) secs
                     right PSF SetInstrumentOffsets failed

 182  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 04:35:03.240 2009  to  Fri Mar 20 04:35:11.549 2009   (  8.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 183  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 04:35:03.293 2009  to  Fri Mar 20 04:35:11.493 2009   (  8.20) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 184  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 04:35:03.360 2009  to  Fri Mar 20 04:35:11.428 2009   (  8.07) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 185  FAILED    IIF        command.moveFocus                                             Fri Mar 20 04:38:22.266 2009  to  Fri Mar 20 04:38:27.902 2009   (  5.64) secs
                     IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for 1.200000000000000e-01

 186  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 04:38:22.329 2009  to  Fri Mar 20 04:38:27.734 2009   (  5.41) secs
                     right PSF SetInstrumentOffsets failed

 187  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 04:38:22.382 2009  to  Fri Mar 20 04:38:27.678 2009   (  5.30) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 188  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 04:38:22.434 2009  to  Fri Mar 20 04:38:27.622 2009   (  5.19) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 189  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 04:38:22.495 2009  to  Fri Mar 20 04:38:27.556 2009   (  5.06) secs
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 190  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:03.979 2009  to  Fri Mar 20 05:10:03.979 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 191  FAILED    PMC        VxInterface.packetReadError                                   Fri Mar 20 05:10:04.031 2009  to  Fri Mar 20 05:10:04.031 2009   (  0.00) secs
                     right PMC PMCLogger packet read error: 5002

 192  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:04.386 2009  to  Fri Mar 20 05:10:04.386 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 193  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:04.741 2009  to  Fri Mar 20 05:10:04.741 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 194  FAILED    PMC        VxInterface.selectTimeout                                     Fri Mar 20 05:10:05.095 2009  to  Fri Mar 20 05:10:05.095 2009   (  0.00) secs
                     right PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 195  FAILED    IIF        command.sendWavefront                                         Fri Mar 20 05:25:39.128 2009  to  Fri Mar 20 05:25:52.132 2009   ( 13.00) secs
                     IIF SendWavefront command started for right LBC for M1
                     IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF SendWavefront command failed for right LBC for M1

 196  FAILED    PSF        command.applyZernikes                                         Fri Mar 20 05:25:39.249 2009  to  Fri Mar 20 05:25:51.955 2009   ( 12.71) secs
                     right PSF ApplyZernikes failed

 197  FAILED    PSF        command.setZernikes                                           Fri Mar 20 05:25:39.197 2009  to  Fri Mar 20 05:25:52.014 2009   ( 12.82) secs
                     right PSF SetZernikes failed for 28 coefficients to ope M1

 198  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Mar 20 05:25:39.411 2009  to  Fri Mar 20 05:25:51.899 2009   ( 12.49) secs
                     right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 199  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 05:25:42.711 2009  to  Fri Mar 20 05:25:51.775 2009   (  9.06) secs
                     right PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 200  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 05:25:42.652 2009  to  Fri Mar 20 05:25:51.842 2009   (  9.19) secs
                     right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 201  FAILED    IIF        command.moveFocus                                             Fri Mar 20 05:26:14.838 2009  to  Fri Mar 20 05:26:21.485 2009   (  6.65) secs
                     IIF GetTrajectory command started for both LBC, start time 5.491051822916666e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                     IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                     IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 202  FAILED    PSF        command.setInstrumentOffsets                                  Fri Mar 20 05:26:14.902 2009  to  Fri Mar 20 05:26:21.315 2009   (  6.41) secs
                     right PSF SetInstrumentOffsets failed

 203  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Mar 20 05:26:15.006 2009  to  Fri Mar 20 05:26:21.204 2009   (  6.20) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 204  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Mar 20 05:26:14.954 2009  to  Fri Mar 20 05:26:21.259 2009   (  6.31) secs
                     right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 205  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Mar 20 05:26:15.068 2009  to  Fri Mar 20 05:26:21.135 2009   (  6.07) secs
                     left PMC Mirror GoToPositionAbs Command Started
                     right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 206  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Mar 20 06:13:27.508 2009  to  Fri Mar 20 06:13:27.508 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 207  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.888 2009  to  Fri Mar 20 06:13:27.888 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 208  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.943 2009  to  Fri Mar 20 06:13:27.943 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 209  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Mar 20 06:13:27.944 2009  to  Fri Mar 20 06:13:27.944 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 210  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Fri Mar 20 06:13:29.511 2009  to  Fri Mar 20 06:13:29.511 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

**********************************************************
    Reporting period ending:   Fri Mar 20 06:52:55.656 2009
********************************************************************************************************