You are here: Foswiki>Software Web>TCSSWReportFile_090317 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 17 2009 to Mar 18 2009
 
    Reporting period beginning:   Tue Mar 17 17:58:02.037 2009
    Reporting period ending:      Wed Mar 18 06:55:56.963 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.MEncoders.earlyStrobe,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    1.88    2.52    0.00    5.73    37.5 %          8                     5           
                                                                       1.76    3.34    2.09    4.58

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:18.972 2009  to  Tue Mar 17 19:46:20.375 2009   (  1.40) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:27.860 2009  to  Tue Mar 17 19:46:28.812 2009   (  0.95) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

   3  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:27.856 2009  to  Tue Mar 17 19:46:32.078 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LUCIFER at bentGregorianFront focus

   4  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:32.078 2009  to  Tue Mar 17 19:46:34.756 2009   (  2.68) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:38.452 2009  to  Tue Mar 17 19:46:44.182 2009   (  5.73) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   6  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:38.462 2009  to  Tue Mar 17 19:46:41.163 2009   (  2.70) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

   7  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:54.133 2009  to  Tue Mar 17 19:46:54.133 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left LUCIFER at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .   58.77   36.52    0.23  445.76    96.4 %         83         65          3         15
                                                                       7.42   27.22   14.55   49.81
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.57    5.88    2.26    9.67   100.0 %         82         82                      
                                                                       1.57    5.88    2.26    9.67
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .    1.32   37.23   36.33   38.75    75.0 %          4          3                     1
                                                                       1.32   37.23   36.33   38.75
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   24.26   68.84    0.00  151.71    81.9 %         72         53         13          7
                                                                      19.12   69.67   40.27  132.91
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    2.79    2.86    1.05   17.08   100.0 %         90         90                      
                                                                       2.79    2.86    1.05   17.08
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   16.95    7.78    2.07  108.28   100.0 %         86         86                      
                                                                      16.95    7.78    2.07  108.28
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   34.19   40.84    1.23  140.53    64.3 %         14          9          5           
                                                                      36.80   51.67   21.36  140.53

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             5

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:27:13.020 2009  to  Tue Mar 17 19:27:14.253 2009   (  1.23) secs
                     IIF Preset command started for left LUCIFER mode TRACK from IIF
                     IIF Preset alert for left LUCIFER mode TRACK: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   2  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:28:02.008 2009  to  Tue Mar 17 19:28:54.333 2009   ( 52.33) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   3  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:33:16.119 2009  to  Tue Mar 17 19:33:32.869 2009   ( 16.75) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   4  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:38:53.038 2009  to  Tue Mar 17 19:39:11.730 2009   ( 18.69) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   5  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:41:03.895 2009  to  Tue Mar 17 19:41:21.651 2009   ( 17.76) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   6  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 20:00:12.372 2009  to  Tue Mar 17 20:02:31.974 2009   (139.60) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 500 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   7  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 22:20:47.135 2009  to  Tue Mar 17 22:23:18.840 2009   (151.71) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   8  SEQERROR  IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:43:18.546 2009  to  Tue Mar 17 23:43:18.546 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   9  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:48:20.988 2009  to  Tue Mar 17 23:49:05.101 2009   ( 44.11) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  10  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:51:39.169 2009  to  Tue Mar 17 23:52:38.746 2009   ( 59.58) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  11  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 00:09:37.832 2009  to  Wed Mar 18 00:10:48.309 2009   ( 70.48) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  12  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 02:59:22.443 2009  to  Wed Mar 18 03:00:37.644 2009   ( 75.20) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  13  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:11:15.974 2009  to  Wed Mar 18 03:12:07.233 2009   ( 51.26) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  14  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:12:36.930 2009  to  Wed Mar 18 03:13:24.037 2009   ( 47.11) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  15  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:25:42.418 2009  to  Wed Mar 18 03:26:35.474 2009   ( 53.06) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  16  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:36:09.046 2009  to  Wed Mar 18 03:37:02.387 2009   ( 53.34) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  17  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 04:05:22.161 2009  to  Wed Mar 18 04:06:19.776 2009   ( 57.61) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  18  FAILED    IIF        command.offset                                                Wed Mar 18 05:48:41.215 2009  to  Wed Mar 18 05:56:06.976 2009   (445.76) secs
                     IIF Offset command wait for telescope started for left LUCIFER
                     IIF Offset alert for left LUCIFER: Invalid buffer: RPCERROR
                     IIF Offset command failed for left LUCIFER from IIF

  19  FAILED    IIF        command.offset                                                Wed Mar 18 06:00:42.292 2009  to  Wed Mar 18 06:05:10.137 2009   (267.85) secs
                     IIF Offset command wait for telescope started for left LUCIFER
                     IIF Offset alert for left LUCIFER: Invalid buffer: RPCERROR
                     IIF Offset command failed for left LUCIFER from IIF

  20  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 06:07:37.073 2009  to  Wed Mar 18 06:08:24.570 2009   ( 47.50) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  21  FAILED    IIF        command.offset                                                Wed Mar 18 06:08:24.997 2009  to  Wed Mar 18 06:08:25.229 2009   (  0.23) secs
                     IIF Offset command started for left LUCIFER from IIF
                     IIF Offset alert for left LUCIFER: guiding is not active
                     IIF Offset command failed for left LUCIFER from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3827                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7653                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      46                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    5.88   20.97    0.00   31.65    97.3 %         73         62          2           
                                                                       5.81   20.76    0.00   31.65
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    3.48    3.09    0.05   11.61    84.9 %         73         62         11           
                                                                       1.24    1.83    0.72    7.83
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    1.91    7.45    1.74    8.39   100.0 %         11         11                      
                                                                       1.91    7.45    1.74    8.39
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getEffectiveGuideRate. . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getMaximumGuideRate. . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getPositionAGW . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getVersionString . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          1                                 
                                                                                                   
     command.offsetGuiding. . . . . . . . . . . . . . . . . . . . .    5.52    8.50    0.00   19.45    82.9 %         82         82         14           
                                                                       5.00    9.74    0.00   19.45
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .                                   100.0 %         13                                 
                                                                                                   
     command.pauseGuiding . . . . . . . . . . . . . . . . . . . . .    0.80    0.73    0.04    3.61    98.8 %         83         82          1           
                                                                       0.80    0.74    0.05    3.61
     command.resumeGuiding. . . . . . . . . . . . . . . . . . . . .    5.56   10.76    0.00   26.54    97.1 %         68         66                     1
                                                                       5.56   10.76    0.00   26.54
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    7.73   24.57   14.57   45.21   100.0 %         77         77                      
                                                                       7.73   24.57   14.57   45.21
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          4                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.03    0.06    0.04    0.30   100.0 %         61         61                      
                                                                       0.03    0.06    0.04    0.30
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          4          4                      
                                                                       0.00    0.06    0.06    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .   12.70    2.53    0.17   96.49    58.2 %         98         57                      
                                                                      12.70    2.53    0.17   96.49
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    0.71    0.45    0.16    5.16    98.3 %         59         58                      
                                                                       0.71    0.45    0.16    5.16
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    4.32   10.45    0.56   24.24    91.2 %        159        145         14           
                                                                       3.21   11.40    7.11   24.24
 *** interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.69    3.15    0.04    9.11    94.9 %       5730       4169        291             interrupted =    57    timeout =   291
                                                                       1.54    3.35    0.67    9.11
 *** interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .   12.03   26.87    0.04   81.38    86.8 %        567        438         75             interrupted =    53
                                                                       4.06   30.81   17.33   32.57
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.12    0.29    0.17    0.68   100.0 %        159        159                      
                                                                       0.12    0.29    0.17    0.68
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    5.75    0.46    0.00  294.51   100.0 %       3975       3976                        interrupted =    12    timeout =     3
                                                                       5.75    0.46    0.00  294.51
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.89    2.48    1.24    5.59   100.0 %         62         62                      
                                                                       0.89    2.48    1.24    5.59
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   42.61   18.82    5.38  565.93    99.7 %        377        376                      
                                                                      42.61   18.82    5.38  565.93
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.64    6.40    5.25    8.88    88.4 %        438        387                      
                                                                       0.64    6.40    5.25    8.88

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .      62                      
 *** guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 72        116
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .      59                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .      61                      
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .      58                      

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar                                  Tue Mar 17 20:02:08.405 2009  to  Tue Mar 17 20:02:31.588 2009   ( 23.18) secs
                     guiding was not stable within 6 cycles

   2  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:44.171 2009  to  Tue Mar 17 20:04:44.223 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   3  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:46.039 2009  to  Tue Mar 17 20:04:46.091 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   4  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:47.595 2009  to  Tue Mar 17 20:04:47.645 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   5  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:50.156 2009  to  Tue Mar 17 20:04:50.209 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   6  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:52.031 2009  to  Tue Mar 17 20:04:52.083 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   7  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:53.610 2009  to  Tue Mar 17 20:04:53.663 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   8  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:55.202 2009  to  Tue Mar 17 20:04:55.254 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

   9  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:57.619 2009  to  Tue Mar 17 20:04:57.671 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  10  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:59.718 2009  to  Tue Mar 17 20:04:59.767 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  11  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:01.141 2009  to  Tue Mar 17 20:05:01.244 2009   (  0.10) secs
                     error requesting an image in WFSingThread. Lost connection?

  12  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:03.955 2009  to  Tue Mar 17 20:05:04.006 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  13  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:06.366 2009  to  Tue Mar 17 20:05:06.419 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  14  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:07.796 2009  to  Tue Mar 17 20:05:07.847 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  15  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:09.321 2009  to  Tue Mar 17 20:05:09.373 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  16  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:11.816 2009  to  Tue Mar 17 20:05:11.868 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  17  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:13.577 2009  to  Tue Mar 17 20:05:13.620 2009   (  0.04) secs
                     error requesting an image in WFSingThread. Lost connection?

  18  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:15.314 2009  to  Tue Mar 17 20:05:15.361 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  19  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:16.827 2009  to  Tue Mar 17 20:05:16.879 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  20  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:19.588 2009  to  Tue Mar 17 20:05:19.639 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  21  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:21.384 2009  to  Tue Mar 17 20:05:21.436 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  22  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:22.987 2009  to  Tue Mar 17 20:05:23.035 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  23  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:24.923 2009  to  Tue Mar 17 20:05:24.974 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  24  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:27.675 2009  to  Tue Mar 17 20:05:27.726 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  25  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:29.442 2009  to  Tue Mar 17 20:05:29.494 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  26  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:30.978 2009  to  Tue Mar 17 20:05:31.030 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  27  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:40.136 2009  to  Tue Mar 17 20:05:43.051 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  28  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:46.412 2009  to  Tue Mar 17 20:05:46.906 2009   (  0.49) secs
                     timeout occured waiting for a guide image

  29  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:51.011 2009  to  Tue Mar 17 20:05:53.918 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  30  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:57.456 2009  to  Tue Mar 17 20:06:00.346 2009   (  2.89) secs
                     timeout occured waiting for a guide image

  31  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:03.666 2009  to  Tue Mar 17 20:06:06.575 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  32  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:10.273 2009  to  Tue Mar 17 20:06:13.182 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  33  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:16.423 2009  to  Tue Mar 17 20:06:19.336 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  34  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:22.682 2009  to  Tue Mar 17 20:06:25.587 2009   (  2.91) secs
                     timeout occured waiting for a guide image

  35  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:28.994 2009  to  Tue Mar 17 20:06:31.893 2009   (  2.90) secs
                     timeout occured waiting for a guide image

  36  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:35.154 2009  to  Tue Mar 17 20:06:38.056 2009   (  2.90) secs
                     timeout occured waiting for a guide image

  37  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:41.376 2009  to  Tue Mar 17 20:06:44.273 2009   (  2.90) secs
                     timeout occured waiting for a guide image

  38  SHUTDOWN  GCS        command.shutdown                                              Tue Mar 17 20:07:11.606 2009  to  Tue Mar 17 20:07:11.606 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  39  SHUTDOWN  GCS        command.shutdown                                              Tue Mar 17 20:07:12.403 2009  to  Tue Mar 17 20:07:12.403 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  40  STARTUP   GCS        startup                                                       Tue Mar 17 20:07:39.134 2009  to  Tue Mar 17 20:07:39.134 2009   (  0.00) secs
                     left GCS subsystem started

  41  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:18.139 2009  to  Tue Mar 17 20:40:18.139 2009   (  0.00) secs
                     no guide star found

  42  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:23.379 2009  to  Tue Mar 17 20:40:23.379 2009   (  0.00) secs
                     no guide star found

  43  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:28.606 2009  to  Tue Mar 17 20:40:28.606 2009   (  0.00) secs
                     no guide star found

  44  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:33.870 2009  to  Tue Mar 17 20:40:33.870 2009   (  0.00) secs
                     no guide star found

  45  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:39.056 2009  to  Tue Mar 17 20:40:39.056 2009   (  0.00) secs
                     no guide star found

  46  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:44.356 2009  to  Tue Mar 17 20:40:44.356 2009   (  0.00) secs
                     no guide star found

  47  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:49.620 2009  to  Tue Mar 17 20:40:49.620 2009   (  0.00) secs
                     no guide star found

  48  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:54.923 2009  to  Tue Mar 17 20:40:54.923 2009   (  0.00) secs
                     no guide star found

  49  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:00.246 2009  to  Tue Mar 17 20:41:00.246 2009   (  0.00) secs
                     no guide star found

  50  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:05.513 2009  to  Tue Mar 17 20:41:05.513 2009   (  0.00) secs
                     no guide star found

  51  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:10.791 2009  to  Tue Mar 17 20:41:10.791 2009   (  0.00) secs
                     no guide star found

  52  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:16.064 2009  to  Tue Mar 17 20:41:16.064 2009   (  0.00) secs
                     no guide star found

  53  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:21.336 2009  to  Tue Mar 17 20:41:21.336 2009   (  0.00) secs
                     no guide star found

  54  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:26.625 2009  to  Tue Mar 17 20:41:26.625 2009   (  0.00) secs
                     no guide star found

  55  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:31.859 2009  to  Tue Mar 17 20:41:31.859 2009   (  0.00) secs
                     no guide star found

  56  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:37.180 2009  to  Tue Mar 17 20:41:37.180 2009   (  0.00) secs
                     no guide star found

  57  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:42.422 2009  to  Tue Mar 17 20:41:42.422 2009   (  0.00) secs
                     no guide star found

  58  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:47.645 2009  to  Tue Mar 17 20:41:47.645 2009   (  0.00) secs
                     no guide star found

  59  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:52.909 2009  to  Tue Mar 17 20:41:52.909 2009   (  0.00) secs
                     no guide star found

  60  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:58.234 2009  to  Tue Mar 17 20:41:58.234 2009   (  0.00) secs
                     no guide star found

  61  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:03.479 2009  to  Tue Mar 17 20:42:03.479 2009   (  0.00) secs
                     no guide star found

  62  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:08.806 2009  to  Tue Mar 17 20:42:08.806 2009   (  0.00) secs
                     no guide star found

  63  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:14.057 2009  to  Tue Mar 17 20:42:14.057 2009   (  0.00) secs
                     no guide star found

  64  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:19.281 2009  to  Tue Mar 17 20:42:19.281 2009   (  0.00) secs
                     no guide star found

  65  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:24.550 2009  to  Tue Mar 17 20:42:24.550 2009   (  0.00) secs
                     no guide star found

  66  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:28:25.919 2009  to  Tue Mar 17 21:28:26.858 2009   (  0.94) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  67  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:28:26.247 2009  to  Tue Mar 17 21:28:26.802 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -488.994, 334.434, focus: -139.032 :AGW1: Requested position is Out of Range

  68  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:31:08.555 2009  to  Tue Mar 17 21:31:09.891 2009   (  1.34) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  69  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:31:09.281 2009  to  Tue Mar 17 21:31:09.837 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -470.42, 334.207, focus: -130.34 :AGW1: Requested position is Out of Range

  70  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:32:54.817 2009  to  Tue Mar 17 21:32:56.006 2009   (  1.19) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  71  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:32:55.330 2009  to  Tue Mar 17 21:32:55.886 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -507.612, 334.679, focus: -148.083 :AGW1: Requested position is Out of Range

  72  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:36:22.207 2009  to  Tue Mar 17 21:36:23.340 2009   (  1.13) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  73  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:36:22.724 2009  to  Tue Mar 17 21:36:23.281 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -563.44, 317, focus: -171.425 :AGW1: Requested position is Out of Range

  74  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:42:18.144 2009  to  Tue Mar 17 21:42:19.489 2009   (  1.34) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  75  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:42:18.626 2009  to  Tue Mar 17 21:42:19.434 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -563.984, 353.944, focus: -183.706 :AGW1: Requested position is Out of Range

  76  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 22:23:07.295 2009  to  Tue Mar 17 22:23:18.603 2009   ( 11.31) secs
                     couldn''t find a star in any GS location.

  77  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:43:07.159 2009  to  Tue Mar 17 23:43:18.315 2009   ( 11.16) secs
                     couldn''t find a star in any GS location.

  78  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:48:53.791 2009  to  Tue Mar 17 23:49:04.870 2009   ( 11.08) secs
                     couldn''t find a star in any GS location.

  79  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:52:27.492 2009  to  Tue Mar 17 23:52:38.534 2009   ( 11.04) secs
                     couldn''t find a star in any GS location.

  80  FAILED    GCS        command.autoAcquireGuidestar                                  Wed Mar 18 00:10:16.374 2009  to  Wed Mar 18 00:10:48.024 2009   ( 31.65) secs
                     guiding was not stable within 6 cycles

  81  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 00:56:27.085 2009  to  Wed Mar 18 00:56:28.392 2009   (  1.31) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  82  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 00:56:27.530 2009  to  Wed Mar 18 00:56:28.338 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -5.04415, 202.921, focus: 10.8922 :AGW1: Requested position is Out of Range

  83  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 01:21:25.846 2009  to  Wed Mar 18 01:21:26.947 2009   (  1.10) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Error on UMAC

  84  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 01:21:26.344 2009  to  Wed Mar 18 01:21:26.900 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -71.2183, 120.615, focus: 21.3744 :AGW1: Error on UMAC

  85  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 02:06:49.874 2009  to  Wed Mar 18 02:06:50.950 2009   (  1.08) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

  86  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 02:06:50.337 2009  to  Wed Mar 18 02:06:50.894 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 109.535, -8.28849, focus: 25.0513 :AGW1: Requested position is Out of Range

  87  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:33.644 2009  to  Wed Mar 18 02:33:41.350 2009   (  7.71) secs
                     timeout occured waiting for a guide image

  88  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:43.111 2009  to  Wed Mar 18 02:33:43.176 2009   (  0.07) secs
                     timeout occured waiting for a guide image

  89  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:46.798 2009  to  Wed Mar 18 02:33:46.861 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  90  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:50.484 2009  to  Wed Mar 18 02:33:50.548 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  91  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:54.170 2009  to  Wed Mar 18 02:33:54.229 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  92  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:57.850 2009  to  Wed Mar 18 02:33:57.914 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  93  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:01.536 2009  to  Wed Mar 18 02:34:01.600 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  94  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:05.223 2009  to  Wed Mar 18 02:34:05.287 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  95  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:08.911 2009  to  Wed Mar 18 02:34:08.977 2009   (  0.07) secs
                     timeout occured waiting for a guide image

  96  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:12.598 2009  to  Wed Mar 18 02:34:12.662 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  97  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:16.284 2009  to  Wed Mar 18 02:34:16.348 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  98  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:19.970 2009  to  Wed Mar 18 02:34:20.034 2009   (  0.06) secs
                     timeout occured waiting for a guide image

  99  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:26.074 2009  to  Wed Mar 18 02:34:26.436 2009   (  0.36) secs
                     timeout occured waiting for a guide image

 100  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:29.754 2009  to  Wed Mar 18 02:34:29.818 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 101  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:00:26.038 2009  to  Wed Mar 18 03:00:37.423 2009   ( 11.39) secs
                     couldn''t find a star in any GS location.

 102  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:11:55.494 2009  to  Wed Mar 18 03:12:07.107 2009   ( 11.61) secs
                     couldn''t find a star in any GS location.

 103  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:13:12.738 2009  to  Wed Mar 18 03:13:23.793 2009   ( 11.05) secs
                     couldn''t find a star in any GS location.

 104  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:26:23.803 2009  to  Wed Mar 18 03:26:35.354 2009   ( 11.55) secs
                     couldn''t find a star in any GS location.

 105  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:36:50.992 2009  to  Wed Mar 18 03:37:02.171 2009   ( 11.18) secs
                     couldn''t find a star in any GS location.

 106  STARTUP   GCS        startup                                                       Wed Mar 18 03:57:01.422 2009  to  Wed Mar 18 03:57:01.422 2009   (  0.00) secs
                     left GCS subsystem started

 107  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 04:06:08.332 2009  to  Wed Mar 18 04:06:19.548 2009   ( 11.22) secs
                     couldn''t find a star in any GS location.

 108  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:22:17.671 2009  to  Wed Mar 18 05:22:18.874 2009   (  1.20) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 109  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:22:18.019 2009  to  Wed Mar 18 05:22:18.826 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 22.035, -496.093, focus: -88.5537 :AGW1: Requested position is Out of Range

 110  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:23:49.835 2009  to  Wed Mar 18 05:23:50.733 2009   (  0.90) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 111  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:23:50.120 2009  to  Wed Mar 18 05:23:50.676 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 3.85268, -477.568, focus: -79.6 :AGW1: Requested position is Out of Range

 112  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:25:17.079 2009  to  Wed Mar 18 05:25:18.525 2009   (  1.45) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 113  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:25:17.411 2009  to  Wed Mar 18 05:25:18.471 2009   (  1.06) secs
                     couldn''t move probe to position (SFP) 40.2421, -514.667, focus: -98.1836 :AGW1: Requested position is Out of Range

 114  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:44:19.152 2009  to  Wed Mar 18 05:44:20.623 2009   (  1.47) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 115  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:44:19.759 2009  to  Wed Mar 18 05:44:20.568 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 41.4432, -515.886, focus: -98.8384 :AGW1: Requested position is Out of Range

 116  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:45:49.009 2009  to  Wed Mar 18 05:45:50.241 2009   (  1.23) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 117  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:45:49.380 2009  to  Wed Mar 18 05:45:50.187 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 23.2654, -534.457, focus: -107.704 :AGW1: Requested position is Out of Range

 118  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:47:15.593 2009  to  Wed Mar 18 05:47:17.326 2009   (  1.73) secs
                    

 119  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:47:16.380 2009  to  Wed Mar 18 05:47:17.187 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 59.5953, -497.361, focus: -90.6461 :AGW1: Requested position is Out of Range

 120  STARTUP   GCS        startup                                                       Wed Mar 18 05:56:16.909 2009  to  Wed Mar 18 05:56:16.909 2009   (  0.00) secs
                     left GCS subsystem started

 121  STARTUP   GCS        startup                                                       Wed Mar 18 06:07:29.422 2009  to  Wed Mar 18 06:07:29.422 2009   (  0.00) secs
                     left GCS subsystem started

 122  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 06:08:24.395 2009  to  Wed Mar 18 06:08:24.447 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

 123  FAILED    GCS        command.pauseGuiding                                          Wed Mar 18 06:08:25.057 2009  to  Wed Mar 18 06:08:25.097 2009   (  0.04) secs
                     guiding is not active
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       7                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               1475           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           111
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      14                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      23                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       7                      
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      28                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.MEncoders.earlyStrobe. . . . . . . . . . . . . . . . . .                             1
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             3
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      31                      
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            11
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      58                      
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  5           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     182                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      91                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     458                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      13                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      19                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     180                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     194                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     122                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     360                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     558                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     542                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.TPlcDevice.readError . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  1           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:02.037 2009  to  Tue Mar 17 17:58:02.037 2009   (  0.00) secs
                     EL bad poly no. 84465: BAD Poly: EL = -4.430208e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:05.094 2009  to  Tue Mar 17 17:58:05.094 2009   (  0.00) secs
                     EL bad poly no. 84512: BAD Poly: EL = -4.428686e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:08.099 2009  to  Tue Mar 17 17:58:08.099 2009   (  0.00) secs
                     EL bad poly no. 84555: BAD Poly: EL = -4.427190e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:11.099 2009  to  Tue Mar 17 17:58:11.099 2009   (  0.00) secs
                     EL bad poly no. 84598: BAD Poly: EL = -4.425696e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:14.161 2009  to  Tue Mar 17 17:58:14.161 2009   (  0.00) secs
                     EL bad poly no. 84645: BAD Poly: EL = -4.424171e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:17.145 2009  to  Tue Mar 17 17:58:17.145 2009   (  0.00) secs
                     EL bad poly no. 84691: BAD Poly: EL = -4.422684e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:20.205 2009  to  Tue Mar 17 17:58:20.205 2009   (  0.00) secs
                     EL bad poly no. 84735: BAD Poly: EL = -4.421160e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:23.268 2009  to  Tue Mar 17 17:58:23.268 2009   (  0.00) secs
                     EL bad poly no. 84779: BAD Poly: EL = -4.419634e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:26.370 2009  to  Tue Mar 17 17:58:26.370 2009   (  0.00) secs
                     EL bad poly no. 84826: BAD Poly: EL = -4.418088e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:29.382 2009  to  Tue Mar 17 17:58:29.382 2009   (  0.00) secs
                     EL bad poly no. 84866: BAD Poly: EL = -4.416587e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:32.463 2009  to  Tue Mar 17 17:58:32.463 2009   (  0.00) secs
                     EL bad poly no. 84911: BAD Poly: EL = -4.415051e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:35.535 2009  to  Tue Mar 17 17:58:35.535 2009   (  0.00) secs
                     EL bad poly no. 84958: BAD Poly: EL = -4.413520e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:38.578 2009  to  Tue Mar 17 17:58:38.578 2009   (  0.00) secs
                     EL bad poly no. 85001: BAD Poly: EL = -4.412003e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:41.678 2009  to  Tue Mar 17 17:58:41.678 2009   (  0.00) secs
                     EL bad poly no. 85045: BAD Poly: EL = -4.410457e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:44.766 2009  to  Tue Mar 17 17:58:44.766 2009   (  0.00) secs
                     EL bad poly no. 85092: BAD Poly: EL = -4.408917e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:47.782 2009  to  Tue Mar 17 17:58:47.782 2009   (  0.00) secs
                     EL bad poly no. 85137: BAD Poly: EL = -4.407413e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:50.840 2009  to  Tue Mar 17 17:58:50.840 2009   (  0.00) secs
                     EL bad poly no. 85178: BAD Poly: EL = -4.405887e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:53.844 2009  to  Tue Mar 17 17:58:53.844 2009   (  0.00) secs
                     EL bad poly no. 85224: BAD Poly: EL = -4.404389e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:56.869 2009  to  Tue Mar 17 17:58:56.869 2009   (  0.00) secs
                     EL bad poly no. 85267: BAD Poly: EL = -4.402879e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:59.879 2009  to  Tue Mar 17 17:58:59.879 2009   (  0.00) secs
                     EL bad poly no. 85308: BAD Poly: EL = -4.401377e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:02.940 2009  to  Tue Mar 17 17:59:02.940 2009   (  0.00) secs
                     EL bad poly no. 85353: BAD Poly: EL = -4.399850e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:05.990 2009  to  Tue Mar 17 17:59:05.990 2009   (  0.00) secs
                     EL bad poly no. 85392: BAD Poly: EL = -4.398327e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:09.062 2009  to  Tue Mar 17 17:59:09.062 2009   (  0.00) secs
                     EL bad poly no. 85438: BAD Poly: EL = -4.396794e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:12.135 2009  to  Tue Mar 17 17:59:12.135 2009   (  0.00) secs
                     EL bad poly no. 85484: BAD Poly: EL = -4.395259e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:15.191 2009  to  Tue Mar 17 17:59:15.191 2009   (  0.00) secs
                     EL bad poly no. 85528: BAD Poly: EL = -4.393734e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Tue Mar 17 19:00:47.349 2009  to  Tue Mar 17 19:00:47.349 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  27  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Tue Mar 17 19:00:51.270 2009  to  Tue Mar 17 19:00:51.270 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Right Bumper limit!

  28  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Tue Mar 17 19:00:51.380 2009  to  Tue Mar 17 19:00:51.380 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Right Bumper limit!

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:12:47.755 2009  to  Tue Mar 17 19:12:47.755 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:12:48.760 2009  to  Tue Mar 17 19:12:48.760 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:27:33.210 2009  to  Tue Mar 17 19:27:33.210 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:27:33.230 2009  to  Tue Mar 17 19:27:33.230 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:27:34.141 2009  to  Tue Mar 17 19:27:34.141 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  34  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue Mar 17 19:27:36.688 2009  to  Tue Mar 17 19:27:36.688 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 4.528843e+00 seconds in the past!

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:46:20.154 2009  to  Tue Mar 17 19:46:20.154 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:46:20.178 2009  to  Tue Mar 17 19:46:20.178 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:46:21.215 2009  to  Tue Mar 17 19:46:21.215 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Wed Mar 18 01:26:32.187 2009  to  Wed Mar 18 01:26:32.187 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 3 times

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Wed Mar 18 06:23:25.211 2009  to  Wed Mar 18 06:23:25.211 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  40  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Wed Mar 18 06:23:25.809 2009  to  Wed Mar 18 06:23:25.809 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  41  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Wed Mar 18 06:23:27.214 2009  to  Wed Mar 18 06:23:27.214 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    3.14    7.28    2.21   20.38    99.7 %        367        366                      
                                                                       3.14    7.28    2.21   20.38
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    1.17    5.12    3.03    8.62    95.6 %         90         86                      
                                                                       1.17    5.12    3.03    8.62
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .    0.00   13.24   13.24   13.24    33.3 %          3          1                      
                                                                       0.00   13.24   13.24   13.24
     side[1].tertiary_mirror.movefocalstation.command . . . . . . .                                   100.0 %          3                                 
                                                                                                   

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             3
     side[0].tertiary_mirror.adjustcurrfocalstation.failed. . . . .                  4           
     side[1].tertiary_mirror.movefocalstation.failed. . . . . . . .                  3           
     side[0].tertiary_mirror.movefocalstation.failed. . . . . . . .                  2           

OSS Events of Interest

   1  STARTUP   OSS        startup                                                       Tue Mar 17 18:29:28.912 2009  to  Tue Mar 17 18:29:28.912 2009   (  0.00) secs
                     The oss was started.

   2  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:28:32.026 2009  to  Tue Mar 17 19:33:30.198 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   3  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:28:32.079 2009  to  Tue Mar 17 19:28:32.079 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   4  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:33:30.252 2009  to  Tue Mar 17 19:33:30.252 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   5  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:33:30.198 2009  to  Tue Mar 17 19:39:06.563 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   6  STARTUP   OSS        startup                                                       Tue Mar 17 19:38:21.907 2009  to  Tue Mar 17 19:38:21.907 2009   (  0.00) secs
                     The oss was started.

   7  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:39:06.617 2009  to  Tue Mar 17 19:39:06.617 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   8  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:39:06.563 2009  to  Tue Mar 17 19:41:18.244 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   9  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:41:18.297 2009  to  Tue Mar 17 19:41:18.297 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  10  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:41:18.244 2009  to  Tue Mar 17 19:47:12.973 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  11  SEQERROR  OSS        side[1].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:20.158 2009  to  Tue Mar 17 19:46:28.594 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[1].tertiary_mirror: [moveFocalStation] command.started

  12  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:20.211 2009  to  Tue Mar 17 19:46:20.211 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  13  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:28.647 2009  to  Tue Mar 17 19:46:28.647 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  14  SEQERROR  OSS        side[1].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:28.594 2009  to  Tue Mar 17 19:46:40.178 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[1].tertiary_mirror: [moveFocalStation] command.started

  15  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:29.767 2009  to  Tue Mar 17 19:46:34.257 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  16  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:34.257 2009  to  Tue Mar 17 19:46:40.809 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  17  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:34.377 2009  to  Tue Mar 17 19:46:34.377 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  18  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:40.749 2009  to  Tue Mar 17 19:46:40.749 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  19  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:40.990 2009  to  Tue Mar 17 19:46:40.990 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  20  SEQERROR  OSS        side[0].secondary_mirror.moveabs.command                      Tue Mar 17 23:36:29.939 2009  to  Tue Mar 17 23:41:49.082 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].secondary_mirror: [moveAbs] command.started
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.10    0.13    0.05    0.41   100.0 %        159        159                      
                                                                       0.10    0.13    0.05    0.41
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.05    0.06    0.04    3.05   100.0 %       3975       3975                      
                                                                       0.05    0.06    0.04    3.05
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.89    2.35    1.11    5.46   100.0 %         62         62                        largeUpdate =    62
                                                                       0.89    2.35    1.11    5.46
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.04    0.06   100.0 %         16         16                      
                                                                       0.00    0.05    0.04    0.06
     telescope.command.loadPointingModel. . . . . . . . . . . . . .    0.00    0.06    0.06    0.06   100.0 %          2          2                      
                                                                       0.00    0.06    0.06    0.06
     telescope.command.offsetTelescopeDETXY . . . . . . . . . . . .    0.03    0.07    0.04    0.21   100.0 %         82         82                      
                                                                       0.03    0.07    0.04    0.21
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.05    0.05    0.06   100.0 %         27         27                      
                                                                       0.00    0.05    0.05    0.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.07    0.10    0.05    0.31   100.0 %         91         91                      
                                                                       0.07    0.10    0.05    0.31
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.14    0.54    0.36    0.67   100.0 %          4          4                      
                                                                       0.14    0.54    0.36    0.67
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.21    0.57    0.30    1.07    98.9 %         91         90          1           
                                                                       0.21    0.58    0.30    1.07
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.05    0.06    0.00    0.11     0.0 %          8                     8           
                                                                       0.01    0.09    0.08    0.11

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Tue Mar 17 19:13:01.629 2009  to  Tue Mar 17 19:13:01.629 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   2  FAILED    PCS        telescope.command.startTracking                               Tue Mar 17 19:27:13.816 2009  to  Tue Mar 17 19:27:14.134 2009   (  0.32) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

   3  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:19.058 2009  to  Tue Mar 17 19:46:19.104 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   4  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:19.241 2009  to  Tue Mar 17 19:46:19.241 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   5  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:32.145 2009  to  Tue Mar 17 19:46:32.215 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   6  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:32.402 2009  to  Tue Mar 17 19:46:32.402 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   7  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:38.525 2009  to  Tue Mar 17 19:46:38.589 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   8  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:38.728 2009  to  Tue Mar 17 19:46:38.728 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.11    2.07    2.05    3.06   100.0 %        348        348                      
                                                                       0.11    2.07    2.05    3.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    2.45    3.06    2.05    8.07   100.0 %          6          6                      
                                                                       2.45    3.06    2.05    8.07
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.73    6.45    2.05   72.19   100.0 %        312        312                      
                                                                       7.73    6.45    2.05   72.19
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06   100.0 %          8          8                      
                                                                       0.01    0.06    0.05    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       5                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            25
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       6                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             3
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 13           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 13           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      13                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     348                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            10
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             3
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             1
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:12:41.451 2009  to  Tue Mar 17 20:12:41.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:12:41.503 2009  to  Tue Mar 17 20:12:41.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:12:47.350 2009  to  Tue Mar 17 20:12:47.350 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   4  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:12:47.402 2009  to  Tue Mar 17 20:12:47.402 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:15:52.422 2009  to  Tue Mar 17 20:15:52.422 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:15:52.475 2009  to  Tue Mar 17 20:15:52.475 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   7  FAILED    PMC        VxInterface.close                                             Tue Mar 17 22:25:50.188 2009  to  Tue Mar 17 22:25:50.188 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 22:25:50.136 2009  to  Tue Mar 17 22:25:50.136 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Tue Mar 17 23:18:20.411 2009  to  Tue Mar 17 23:18:20.411 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 23:18:20.360 2009  to  Tue Mar 17 23:18:20.360 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  11  FAILED    PMC        VxInterface.close                                             Tue Mar 17 23:18:33.109 2009  to  Tue Mar 17 23:18:33.109 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 23:18:33.057 2009  to  Tue Mar 17 23:18:33.057 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  13  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 01:26:20.495 2009  to  Wed Mar 18 01:26:20.495 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Wed Mar 18 01:26:20.547 2009  to  Wed Mar 18 01:26:20.547 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.close                                             Wed Mar 18 03:03:05.369 2009  to  Wed Mar 18 03:03:05.369 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 03:03:05.316 2009  to  Wed Mar 18 03:03:05.316 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.selectTimeout                                     Wed Mar 18 03:58:02.813 2009  to  Wed Mar 18 03:58:02.813 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  18  FAILED    PMC        thermal.badReceive                                            Wed Mar 18 03:58:02.917 2009  to  Wed Mar 18 03:58:02.917 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  19  FAILED    PMC        VxInterface.packetReadError                                   Wed Mar 18 03:58:02.865 2009  to  Wed Mar 18 03:58:02.865 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  20  FAILED    PMC        VxInterface.close                                             Wed Mar 18 04:11:45.547 2009  to  Wed Mar 18 04:11:45.547 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 04:11:45.494 2009  to  Wed Mar 18 04:11:45.494 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Wed Mar 18 04:48:21.915 2009  to  Wed Mar 18 04:48:21.915 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 04:48:21.863 2009  to  Wed Mar 18 04:48:21.863 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

  24  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 05:37:48.513 2009  to  Wed Mar 18 05:37:48.513 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  25  FAILED    PMC        VxInterface.close                                             Wed Mar 18 05:37:48.565 2009  to  Wed Mar 18 05:37:48.565 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 05:41:56.776 2009  to  Wed Mar 18 05:41:56.776 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Wed Mar 18 05:41:56.828 2009  to  Wed Mar 18 05:41:56.828 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 06:00:09.611 2009  to  Wed Mar 18 06:00:09.611 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

  29  FAILED    PMC        VxInterface.close                                             Wed Mar 18 06:00:09.696 2009  to  Wed Mar 18 06:00:09.696 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

  30  FAILED    PMC        VxInterface.selectTimeout                                     Wed Mar 18 06:44:43.121 2009  to  Wed Mar 18 06:44:43.121 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  31  FAILED    PMC        VxInterface.packetReadError                                   Wed Mar 18 06:44:43.174 2009  to  Wed Mar 18 06:44:43.174 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  32  FAILED    PMC        thermal.badReceive                                            Wed Mar 18 06:44:43.226 2009  to  Wed Mar 18 06:44:43.226 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .   16.81   11.66    4.84  332.78   100.0 %        377        377                      
                                                                      16.81   11.66    4.84  332.78
     command.config . . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    2.74    1.36    0.25   12.42   100.0 %        136        136                      
                                                                       2.74    1.36    0.25   12.42
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    1.14    0.64    0.05    3.42   100.0 %          8          8                      
                                                                       1.14    0.64    0.05    3.42
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .   16.81   11.77    4.95  332.89   100.0 %        377        377                      
                                                                      16.81   11.77    4.95  332.89
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    5.42    5.46    0.19   97.18   100.0 %        378        378                      
                                                                       5.42    5.46    0.19   97.18
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.73    6.59    2.17   72.32   100.0 %        312        312                      
                                                                       7.73    6.59    2.17   72.32
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    2.45    3.19    2.18    8.20   100.0 %          6          6                      
                                                                       2.45    3.19    2.18    8.20
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.10    0.06    0.37   100.0 %       1885       1885                      
                                                                       0.03    0.10    0.06    0.37
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    1.48    0.85    0.10    3.07   100.0 %          4          4                      
                                                                       1.48    0.85    0.10    3.07
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   34.28   23.34    4.58   74.70   100.0 %          4          4                      
                                                                      34.28   23.34    4.58   74.70
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    7.06   11.13    3.29   29.34   100.0 %         15         15                      
                                                                       7.06   11.13    3.29   29.34
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.05    0.05    0.11   100.0 %        136        136                      
                                                                       0.01    0.05    0.05    0.11
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .   16.85   31.87   16.32   55.40   100.0 %          4          4                      
                                                                      16.85   31.87   16.32   55.40
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.05    0.05    0.11   100.0 %        377        377                      
                                                                       0.00    0.05    0.05    0.11
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.58    8.84    3.77   16.33    99.6 %        226        225                      
                                                                       1.58    8.84    3.77   16.33
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    3.11    7.46    2.34   20.51    99.7 %        367        366                      
                                                                       3.11    7.46    2.34   20.51
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.05    0.04    0.10   100.0 %        136        136                      
                                                                       0.01    0.05    0.04    0.10
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.01    0.08    0.07    0.09   100.0 %          4          4                      
                                                                       0.01    0.08    0.07    0.09
     secondaryMirror.command.revert . . . . . . . . . . . . . . . .    2.49    4.15    2.71    7.02   100.0 %          3          3                      
                                                                       2.49    4.15    2.71    7.02
     secondaryMirror.command.setGlobalOffsets . . . . . . . . . . .    1.32   14.65   13.74   16.16   100.0 %          3          3                      
                                                                       1.32   14.65   13.74   16.16
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.01    0.06    0.05    0.12   100.0 %        226        226                      
                                                                       0.01    0.06    0.05    0.12
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    1.63    5.21    0.42    9.26    95.6 %         90         86          4           
                                                                       1.34    5.42    3.24    9.26
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.04    0.08    0.06    0.14   100.0 %          4          4                      
                                                                       0.04    0.08    0.06    0.14

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     primaryMirror.positionError. . . . . . . . . . . . . . . . . .                  2           

PSF Events of Interest

   1  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:28:31.964 2009  to  Tue Mar 17 19:28:32.769 2009   (  0.80) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   2  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:33:30.133 2009  to  Tue Mar 17 19:33:30.729 2009   (  0.60) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   3  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:39:06.400 2009  to  Tue Mar 17 19:39:07.374 2009   (  0.97) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   4  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:41:18.182 2009  to  Tue Mar 17 19:41:18.599 2009   (  0.42) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

   5  SEQERROR  PSF        secondaryMirror.command.adjustMirror                          Tue Mar 17 23:36:29.826 2009  to  Tue Mar 17 23:41:48.966 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting secondary mirror forces

   6  SEQERROR  PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Mar 17 23:36:29.882 2009  to  Tue Mar 17 23:41:49.022 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future

   7  FAILED    PSF        primaryMirror.positionError                                   Wed Mar 18 01:18:01.065 2009  to  Wed Mar 18 01:18:01.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.6341629e-04 3.4123659e-04 -4.2383373e-04 2.5482178e-03 1.6587067e-01 1.2408257e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Wed Mar 18 01:18:01.320 2009  to  Wed Mar 18 01:18:01.320 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.6341629e-04 3.4123659e-04 -4.2383373e-04 2.5482178e-03 1.6587067e-01 1.2408257e-02
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:02.037 2009  to  Tue Mar 17 17:58:02.037 2009   (  0.00) secs
                     EL bad poly no. 84465: BAD Poly: EL = -4.430208e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:05.094 2009  to  Tue Mar 17 17:58:05.094 2009   (  0.00) secs
                     EL bad poly no. 84512: BAD Poly: EL = -4.428686e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:08.099 2009  to  Tue Mar 17 17:58:08.099 2009   (  0.00) secs
                     EL bad poly no. 84555: BAD Poly: EL = -4.427190e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:11.099 2009  to  Tue Mar 17 17:58:11.099 2009   (  0.00) secs
                     EL bad poly no. 84598: BAD Poly: EL = -4.425696e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:14.161 2009  to  Tue Mar 17 17:58:14.161 2009   (  0.00) secs
                     EL bad poly no. 84645: BAD Poly: EL = -4.424171e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:17.145 2009  to  Tue Mar 17 17:58:17.145 2009   (  0.00) secs
                     EL bad poly no. 84691: BAD Poly: EL = -4.422684e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:20.205 2009  to  Tue Mar 17 17:58:20.205 2009   (  0.00) secs
                     EL bad poly no. 84735: BAD Poly: EL = -4.421160e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:23.268 2009  to  Tue Mar 17 17:58:23.268 2009   (  0.00) secs
                     EL bad poly no. 84779: BAD Poly: EL = -4.419634e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:26.370 2009  to  Tue Mar 17 17:58:26.370 2009   (  0.00) secs
                     EL bad poly no. 84826: BAD Poly: EL = -4.418088e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:29.382 2009  to  Tue Mar 17 17:58:29.382 2009   (  0.00) secs
                     EL bad poly no. 84866: BAD Poly: EL = -4.416587e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:32.463 2009  to  Tue Mar 17 17:58:32.463 2009   (  0.00) secs
                     EL bad poly no. 84911: BAD Poly: EL = -4.415051e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:35.535 2009  to  Tue Mar 17 17:58:35.535 2009   (  0.00) secs
                     EL bad poly no. 84958: BAD Poly: EL = -4.413520e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:38.578 2009  to  Tue Mar 17 17:58:38.578 2009   (  0.00) secs
                     EL bad poly no. 85001: BAD Poly: EL = -4.412003e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:41.678 2009  to  Tue Mar 17 17:58:41.678 2009   (  0.00) secs
                     EL bad poly no. 85045: BAD Poly: EL = -4.410457e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:44.766 2009  to  Tue Mar 17 17:58:44.766 2009   (  0.00) secs
                     EL bad poly no. 85092: BAD Poly: EL = -4.408917e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:47.782 2009  to  Tue Mar 17 17:58:47.782 2009   (  0.00) secs
                     EL bad poly no. 85137: BAD Poly: EL = -4.407413e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:50.840 2009  to  Tue Mar 17 17:58:50.840 2009   (  0.00) secs
                     EL bad poly no. 85178: BAD Poly: EL = -4.405887e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:53.844 2009  to  Tue Mar 17 17:58:53.844 2009   (  0.00) secs
                     EL bad poly no. 85224: BAD Poly: EL = -4.404389e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:56.869 2009  to  Tue Mar 17 17:58:56.869 2009   (  0.00) secs
                     EL bad poly no. 85267: BAD Poly: EL = -4.402879e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:58:59.879 2009  to  Tue Mar 17 17:58:59.879 2009   (  0.00) secs
                     EL bad poly no. 85308: BAD Poly: EL = -4.401377e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:02.940 2009  to  Tue Mar 17 17:59:02.940 2009   (  0.00) secs
                     EL bad poly no. 85353: BAD Poly: EL = -4.399850e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:05.990 2009  to  Tue Mar 17 17:59:05.990 2009   (  0.00) secs
                     EL bad poly no. 85392: BAD Poly: EL = -4.398327e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:09.062 2009  to  Tue Mar 17 17:59:09.062 2009   (  0.00) secs
                     EL bad poly no. 85438: BAD Poly: EL = -4.396794e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:12.135 2009  to  Tue Mar 17 17:59:12.135 2009   (  0.00) secs
                     EL bad poly no. 85484: BAD Poly: EL = -4.395259e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Mar 17 17:59:15.191 2009  to  Tue Mar 17 17:59:15.191 2009   (  0.00) secs
                     EL bad poly no. 85528: BAD Poly: EL = -4.393734e-01 rad. Too low.

  26  STARTUP   OSS        startup                                                       Tue Mar 17 18:29:28.912 2009  to  Tue Mar 17 18:29:28.912 2009   (  0.00) secs
                     The oss was started.

  27  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Tue Mar 17 19:00:47.349 2009  to  Tue Mar 17 19:00:47.349 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  28  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Tue Mar 17 19:00:51.270 2009  to  Tue Mar 17 19:00:51.270 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Right Bumper limit!

  29  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Tue Mar 17 19:00:51.380 2009  to  Tue Mar 17 19:00:51.380 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Right Bumper limit!

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:12:47.755 2009  to  Tue Mar 17 19:12:47.755 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:12:48.760 2009  to  Tue Mar 17 19:12:48.760 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  32  STARTUP   PCS        startup                                                       Tue Mar 17 19:13:01.629 2009  to  Tue Mar 17 19:13:01.629 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

  33  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:27:13.020 2009  to  Tue Mar 17 19:27:14.253 2009   (  1.23) secs
                     IIF Preset command started for left LUCIFER mode TRACK from IIF
                     IIF Preset alert for left LUCIFER mode TRACK: PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  34  FAILED    PCS        telescope.command.startTracking                               Tue Mar 17 19:27:13.816 2009  to  Tue Mar 17 19:27:14.134 2009   (  0.32) secs
                     PCS will start tracking target
                     PCS reports MCSPU error returned - ERROR rotator is not movable (Not ''READY'' for some reason).

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:27:33.210 2009  to  Tue Mar 17 19:27:33.210 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:27:33.230 2009  to  Tue Mar 17 19:27:33.230 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:27:34.141 2009  to  Tue Mar 17 19:27:34.141 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Tue Mar 17 19:27:36.688 2009  to  Tue Mar 17 19:27:36.688 2009   (  0.00) secs
                     LFBG bad poly no. 1: t0 is 4.528843e+00 seconds in the past!

  39  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:28:02.008 2009  to  Tue Mar 17 19:28:54.333 2009   ( 52.33) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  40  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:28:32.026 2009  to  Tue Mar 17 19:33:30.198 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  41  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:28:31.964 2009  to  Tue Mar 17 19:28:32.769 2009   (  0.80) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  42  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:28:32.079 2009  to  Tue Mar 17 19:28:32.079 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  43  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:33:16.119 2009  to  Tue Mar 17 19:33:32.869 2009   ( 16.75) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  44  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:33:30.133 2009  to  Tue Mar 17 19:33:30.729 2009   (  0.60) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  45  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:33:30.252 2009  to  Tue Mar 17 19:33:30.252 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  46  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:33:30.198 2009  to  Tue Mar 17 19:39:06.563 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  47  STARTUP   OSS        startup                                                       Tue Mar 17 19:38:21.907 2009  to  Tue Mar 17 19:38:21.907 2009   (  0.00) secs
                     The oss was started.

  48  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:38:53.038 2009  to  Tue Mar 17 19:39:11.730 2009   ( 18.69) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  49  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:39:06.400 2009  to  Tue Mar 17 19:39:07.374 2009   (  0.97) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  50  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:39:06.617 2009  to  Tue Mar 17 19:39:06.617 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  51  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:39:06.563 2009  to  Tue Mar 17 19:41:18.244 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  52  FAILED    IIF        command.preset.(TRACK)                                        Tue Mar 17 19:41:03.895 2009  to  Tue Mar 17 19:41:21.651 2009   ( 17.76) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  53  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Tue Mar 17 19:41:18.182 2009  to  Tue Mar 17 19:41:18.599 2009   (  0.42) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  54  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Tue Mar 17 19:41:18.297 2009  to  Tue Mar 17 19:41:18.297 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  55  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Tue Mar 17 19:41:18.244 2009  to  Tue Mar 17 19:47:12.973 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  56  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:18.972 2009  to  Tue Mar 17 19:46:20.375 2009   (  1.40) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

  57  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:19.058 2009  to  Tue Mar 17 19:46:19.104 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  58  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:19.241 2009  to  Tue Mar 17 19:46:19.241 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  59  SEQERROR  OSS        side[1].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:20.158 2009  to  Tue Mar 17 19:46:28.594 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[1].tertiary_mirror: [moveFocalStation] command.started

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:46:20.154 2009  to  Tue Mar 17 19:46:20.154 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Tue Mar 17 19:46:20.178 2009  to  Tue Mar 17 19:46:20.178 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  62  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:20.211 2009  to  Tue Mar 17 19:46:20.211 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  63  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Tue Mar 17 19:46:21.215 2009  to  Tue Mar 17 19:46:21.215 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  64  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:27.860 2009  to  Tue Mar 17 19:46:28.812 2009   (  0.95) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

  65  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:27.856 2009  to  Tue Mar 17 19:46:32.078 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LUCIFER at bentGregorianFront focus

  66  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:28.647 2009  to  Tue Mar 17 19:46:28.647 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  67  SEQERROR  OSS        side[1].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:28.594 2009  to  Tue Mar 17 19:46:40.178 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[1].tertiary_mirror: [moveFocalStation] command.started

  68  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:29.767 2009  to  Tue Mar 17 19:46:34.257 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  69  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:32.078 2009  to  Tue Mar 17 19:46:34.756 2009   (  2.68) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

  70  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:32.145 2009  to  Tue Mar 17 19:46:32.215 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  71  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:32.402 2009  to  Tue Mar 17 19:46:32.402 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  72  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Tue Mar 17 19:46:34.257 2009  to  Tue Mar 17 19:46:40.809 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  73  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:34.377 2009  to  Tue Mar 17 19:46:34.377 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  74  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:38.452 2009  to  Tue Mar 17 19:46:44.182 2009   (  5.73) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

  75  FAILED    IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:38.462 2009  to  Tue Mar 17 19:46:41.163 2009   (  2.70) secs
                     IIF TCS authorize command started for right LUCIFER at bentGregorianFront focus
                     IIF TCS authorize alert for right LUCIFER at bentGregorianFront focus: oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for right LUCIFER at bentGregorianFront focus

  76  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:38.525 2009  to  Tue Mar 17 19:46:38.589 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  77  SEQERROR  PCS        telescope.command.stopTracking                                Tue Mar 17 19:46:38.728 2009  to  Tue Mar 17 19:46:38.728 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  78  FAILED    OSS        side[1].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:40.749 2009  to  Tue Mar 17 19:46:40.749 2009   (  0.00) secs
                     oss.side[1].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  79  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Tue Mar 17 19:46:40.990 2009  to  Tue Mar 17 19:46:40.990 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  80  SEQERROR  IIF GUI    IIFCommand.authorize                                          Tue Mar 17 19:46:54.133 2009  to  Tue Mar 17 19:46:54.133 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left LUCIFER at bentGregorianFront focus

  81  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 20:00:12.372 2009  to  Tue Mar 17 20:02:31.974 2009   (139.60) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: WARNING: guide cam exposure time is less than 2000 ms which might cause guiding on atmospheric dispersions
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 500 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  82  FAILED    GCS        command.autoAcquireGuidestar                                  Tue Mar 17 20:02:08.405 2009  to  Tue Mar 17 20:02:31.588 2009   ( 23.18) secs
                     guiding was not stable within 6 cycles

  83  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:44.171 2009  to  Tue Mar 17 20:04:44.223 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  84  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:46.039 2009  to  Tue Mar 17 20:04:46.091 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  85  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:47.595 2009  to  Tue Mar 17 20:04:47.645 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  86  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:50.156 2009  to  Tue Mar 17 20:04:50.209 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  87  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:52.031 2009  to  Tue Mar 17 20:04:52.083 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  88  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:53.610 2009  to  Tue Mar 17 20:04:53.663 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  89  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:55.202 2009  to  Tue Mar 17 20:04:55.254 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  90  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:57.619 2009  to  Tue Mar 17 20:04:57.671 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  91  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:04:59.718 2009  to  Tue Mar 17 20:04:59.767 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  92  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:01.141 2009  to  Tue Mar 17 20:05:01.244 2009   (  0.10) secs
                     error requesting an image in WFSingThread. Lost connection?

  93  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:03.955 2009  to  Tue Mar 17 20:05:04.006 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  94  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:06.366 2009  to  Tue Mar 17 20:05:06.419 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  95  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:07.796 2009  to  Tue Mar 17 20:05:07.847 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  96  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:09.321 2009  to  Tue Mar 17 20:05:09.373 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  97  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:11.816 2009  to  Tue Mar 17 20:05:11.868 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

  98  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:13.577 2009  to  Tue Mar 17 20:05:13.620 2009   (  0.04) secs
                     error requesting an image in WFSingThread. Lost connection?

  99  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:15.314 2009  to  Tue Mar 17 20:05:15.361 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 100  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:16.827 2009  to  Tue Mar 17 20:05:16.879 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 101  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:19.588 2009  to  Tue Mar 17 20:05:19.639 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 102  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:21.384 2009  to  Tue Mar 17 20:05:21.436 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 103  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:22.987 2009  to  Tue Mar 17 20:05:23.035 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 104  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:24.923 2009  to  Tue Mar 17 20:05:24.974 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 105  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:27.675 2009  to  Tue Mar 17 20:05:27.726 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 106  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:29.442 2009  to  Tue Mar 17 20:05:29.494 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 107  FAILED    GCS        interface.azcam.wfsc.readout                                  Tue Mar 17 20:05:30.978 2009  to  Tue Mar 17 20:05:31.030 2009   (  0.05) secs
                     error requesting an image in WFSingThread. Lost connection?

 108  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:40.136 2009  to  Tue Mar 17 20:05:43.051 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 109  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:46.412 2009  to  Tue Mar 17 20:05:46.906 2009   (  0.49) secs
                     timeout occured waiting for a guide image

 110  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:51.011 2009  to  Tue Mar 17 20:05:53.918 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 111  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:05:57.456 2009  to  Tue Mar 17 20:06:00.346 2009   (  2.89) secs
                     timeout occured waiting for a guide image

 112  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:03.666 2009  to  Tue Mar 17 20:06:06.575 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 113  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:10.273 2009  to  Tue Mar 17 20:06:13.182 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 114  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:16.423 2009  to  Tue Mar 17 20:06:19.336 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 115  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:22.682 2009  to  Tue Mar 17 20:06:25.587 2009   (  2.91) secs
                     timeout occured waiting for a guide image

 116  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:28.994 2009  to  Tue Mar 17 20:06:31.893 2009   (  2.90) secs
                     timeout occured waiting for a guide image

 117  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:35.154 2009  to  Tue Mar 17 20:06:38.056 2009   (  2.90) secs
                     timeout occured waiting for a guide image

 118  FAILED    GCS        interface.azcam.guider.readout                                Tue Mar 17 20:06:41.376 2009  to  Tue Mar 17 20:06:44.273 2009   (  2.90) secs
                     timeout occured waiting for a guide image

 119  SHUTDOWN  GCS        command.shutdown                                              Tue Mar 17 20:07:11.606 2009  to  Tue Mar 17 20:07:11.606 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 120  SHUTDOWN  GCS        command.shutdown                                              Tue Mar 17 20:07:12.403 2009  to  Tue Mar 17 20:07:12.403 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 121  STARTUP   GCS        startup                                                       Tue Mar 17 20:07:39.134 2009  to  Tue Mar 17 20:07:39.134 2009   (  0.00) secs
                     left GCS subsystem started

 122  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:12:41.451 2009  to  Tue Mar 17 20:12:41.451 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 123  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:12:41.503 2009  to  Tue Mar 17 20:12:41.503 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 124  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:12:47.350 2009  to  Tue Mar 17 20:12:47.350 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 125  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:12:47.402 2009  to  Tue Mar 17 20:12:47.402 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 126  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 20:15:52.422 2009  to  Tue Mar 17 20:15:52.422 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 127  FAILED    PMC        VxInterface.close                                             Tue Mar 17 20:15:52.475 2009  to  Tue Mar 17 20:15:52.475 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 128  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:18.139 2009  to  Tue Mar 17 20:40:18.139 2009   (  0.00) secs
                     no guide star found

 129  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:23.379 2009  to  Tue Mar 17 20:40:23.379 2009   (  0.00) secs
                     no guide star found

 130  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:28.606 2009  to  Tue Mar 17 20:40:28.606 2009   (  0.00) secs
                     no guide star found

 131  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:33.870 2009  to  Tue Mar 17 20:40:33.870 2009   (  0.00) secs
                     no guide star found

 132  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:39.056 2009  to  Tue Mar 17 20:40:39.056 2009   (  0.00) secs
                     no guide star found

 133  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:44.356 2009  to  Tue Mar 17 20:40:44.356 2009   (  0.00) secs
                     no guide star found

 134  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:49.620 2009  to  Tue Mar 17 20:40:49.620 2009   (  0.00) secs
                     no guide star found

 135  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:40:54.923 2009  to  Tue Mar 17 20:40:54.923 2009   (  0.00) secs
                     no guide star found

 136  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:00.246 2009  to  Tue Mar 17 20:41:00.246 2009   (  0.00) secs
                     no guide star found

 137  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:05.513 2009  to  Tue Mar 17 20:41:05.513 2009   (  0.00) secs
                     no guide star found

 138  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:10.791 2009  to  Tue Mar 17 20:41:10.791 2009   (  0.00) secs
                     no guide star found

 139  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:16.064 2009  to  Tue Mar 17 20:41:16.064 2009   (  0.00) secs
                     no guide star found

 140  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:21.336 2009  to  Tue Mar 17 20:41:21.336 2009   (  0.00) secs
                     no guide star found

 141  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:26.625 2009  to  Tue Mar 17 20:41:26.625 2009   (  0.00) secs
                     no guide star found

 142  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:31.859 2009  to  Tue Mar 17 20:41:31.859 2009   (  0.00) secs
                     no guide star found

 143  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:37.180 2009  to  Tue Mar 17 20:41:37.180 2009   (  0.00) secs
                     no guide star found

 144  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:42.422 2009  to  Tue Mar 17 20:41:42.422 2009   (  0.00) secs
                     no guide star found

 145  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:47.645 2009  to  Tue Mar 17 20:41:47.645 2009   (  0.00) secs
                     no guide star found

 146  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:52.909 2009  to  Tue Mar 17 20:41:52.909 2009   (  0.00) secs
                     no guide star found

 147  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:41:58.234 2009  to  Tue Mar 17 20:41:58.234 2009   (  0.00) secs
                     no guide star found

 148  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:03.479 2009  to  Tue Mar 17 20:42:03.479 2009   (  0.00) secs
                     no guide star found

 149  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:08.806 2009  to  Tue Mar 17 20:42:08.806 2009   (  0.00) secs
                     no guide star found

 150  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:14.057 2009  to  Tue Mar 17 20:42:14.057 2009   (  0.00) secs
                     no guide star found

 151  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:19.281 2009  to  Tue Mar 17 20:42:19.281 2009   (  0.00) secs
                     no guide star found

 152  FAILED    GCS        guidethread.warning                                           Tue Mar 17 20:42:24.550 2009  to  Tue Mar 17 20:42:24.550 2009   (  0.00) secs
                     no guide star found

 153  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:28:25.919 2009  to  Tue Mar 17 21:28:26.858 2009   (  0.94) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 154  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:28:26.247 2009  to  Tue Mar 17 21:28:26.802 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -488.994, 334.434, focus: -139.032 :AGW1: Requested position is Out of Range

 155  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:31:08.555 2009  to  Tue Mar 17 21:31:09.891 2009   (  1.34) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 156  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:31:09.281 2009  to  Tue Mar 17 21:31:09.837 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -470.42, 334.207, focus: -130.34 :AGW1: Requested position is Out of Range

 157  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:32:54.817 2009  to  Tue Mar 17 21:32:56.006 2009   (  1.19) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 158  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:32:55.330 2009  to  Tue Mar 17 21:32:55.886 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -507.612, 334.679, focus: -148.083 :AGW1: Requested position is Out of Range

 159  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:36:22.207 2009  to  Tue Mar 17 21:36:23.340 2009   (  1.13) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 160  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:36:22.724 2009  to  Tue Mar 17 21:36:23.281 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -563.44, 317, focus: -171.425 :AGW1: Requested position is Out of Range

 161  FAILED    GCS        command.offsetGuiding                                         Tue Mar 17 21:42:18.144 2009  to  Tue Mar 17 21:42:19.489 2009   (  1.34) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 162  FAILED    GCS        interface.agw.setProbePosition                                Tue Mar 17 21:42:18.626 2009  to  Tue Mar 17 21:42:19.434 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -563.984, 353.944, focus: -183.706 :AGW1: Requested position is Out of Range

 163  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 22:20:47.135 2009  to  Tue Mar 17 22:23:18.840 2009   (151.71) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 164  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 22:23:07.295 2009  to  Tue Mar 17 22:23:18.603 2009   ( 11.31) secs
                     couldn''t find a star in any GS location.

 165  FAILED    PMC        VxInterface.close                                             Tue Mar 17 22:25:50.188 2009  to  Tue Mar 17 22:25:50.188 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 166  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 22:25:50.136 2009  to  Tue Mar 17 22:25:50.136 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 167  FAILED    PMC        VxInterface.close                                             Tue Mar 17 23:18:20.411 2009  to  Tue Mar 17 23:18:20.411 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 168  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 23:18:20.360 2009  to  Tue Mar 17 23:18:20.360 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 169  FAILED    PMC        VxInterface.close                                             Tue Mar 17 23:18:33.109 2009  to  Tue Mar 17 23:18:33.109 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 170  FAILED    PMC        VxInterface.lengthError                                       Tue Mar 17 23:18:33.057 2009  to  Tue Mar 17 23:18:33.057 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 171  SEQERROR  PSF        secondaryMirror.command.adjustMirror                          Tue Mar 17 23:36:29.826 2009  to  Tue Mar 17 23:41:48.966 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF adjusting secondary mirror forces

 172  SEQERROR  PSF        secondaryMirror.command.adjustMirrorCollimation               Tue Mar 17 23:36:29.882 2009  to  Tue Mar 17 23:41:49.022 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF secondary mirror adjustMirrorCollimation started for 0 seconds in the future

 173  SEQERROR  OSS        side[0].secondary_mirror.moveabs.command                      Tue Mar 17 23:36:29.939 2009  to  Tue Mar 17 23:41:49.082 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].secondary_mirror: [moveAbs] command.started

 174  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:43:07.159 2009  to  Tue Mar 17 23:43:18.315 2009   ( 11.16) secs
                     couldn''t find a star in any GS location.

 175  SEQERROR  IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:43:18.546 2009  to  Tue Mar 17 23:43:18.546 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 176  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:48:20.988 2009  to  Tue Mar 17 23:49:05.101 2009   ( 44.11) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 177  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:48:53.791 2009  to  Tue Mar 17 23:49:04.870 2009   ( 11.08) secs
                     couldn''t find a star in any GS location.

 178  FAILED    IIF        command.preset.(ACTIVE)                                       Tue Mar 17 23:51:39.169 2009  to  Tue Mar 17 23:52:38.746 2009   ( 59.58) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 179  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Tue Mar 17 23:52:27.492 2009  to  Tue Mar 17 23:52:38.534 2009   ( 11.04) secs
                     couldn''t find a star in any GS location.

 180  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 00:09:37.832 2009  to  Wed Mar 18 00:10:48.309 2009   ( 70.48) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 181  FAILED    GCS        command.autoAcquireGuidestar                                  Wed Mar 18 00:10:16.374 2009  to  Wed Mar 18 00:10:48.024 2009   ( 31.65) secs
                     guiding was not stable within 6 cycles

 182  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 00:56:27.085 2009  to  Wed Mar 18 00:56:28.392 2009   (  1.31) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 183  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 00:56:27.530 2009  to  Wed Mar 18 00:56:28.338 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) -5.04415, 202.921, focus: 10.8922 :AGW1: Requested position is Out of Range

 184  FAILED    PSF        primaryMirror.positionError                                   Wed Mar 18 01:18:01.065 2009  to  Wed Mar 18 01:18:01.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.6341629e-04 3.4123659e-04 -4.2383373e-04 2.5482178e-03 1.6587067e-01 1.2408257e-02

 185  FAILED    PSF        primaryMirror.positionError                                   Wed Mar 18 01:18:01.320 2009  to  Wed Mar 18 01:18:01.320 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: 7.6341629e-04 3.4123659e-04 -4.2383373e-04 2.5482178e-03 1.6587067e-01 1.2408257e-02

 186  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 01:21:25.846 2009  to  Wed Mar 18 01:21:26.947 2009   (  1.10) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Error on UMAC

 187  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 01:21:26.344 2009  to  Wed Mar 18 01:21:26.900 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) -71.2183, 120.615, focus: 21.3744 :AGW1: Error on UMAC

 188  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 01:26:20.495 2009  to  Wed Mar 18 01:26:20.495 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 189  FAILED    PMC        VxInterface.close                                             Wed Mar 18 01:26:20.547 2009  to  Wed Mar 18 01:26:20.547 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 190  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Wed Mar 18 01:26:32.187 2009  to  Wed Mar 18 01:26:32.187 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 3 times

 191  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 02:06:49.874 2009  to  Wed Mar 18 02:06:50.950 2009   (  1.08) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 192  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 02:06:50.337 2009  to  Wed Mar 18 02:06:50.894 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 109.535, -8.28849, focus: 25.0513 :AGW1: Requested position is Out of Range

 193  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:33.644 2009  to  Wed Mar 18 02:33:41.350 2009   (  7.71) secs
                     timeout occured waiting for a guide image

 194  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:43.111 2009  to  Wed Mar 18 02:33:43.176 2009   (  0.07) secs
                     timeout occured waiting for a guide image

 195  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:46.798 2009  to  Wed Mar 18 02:33:46.861 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 196  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:50.484 2009  to  Wed Mar 18 02:33:50.548 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 197  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:54.170 2009  to  Wed Mar 18 02:33:54.229 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 198  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:33:57.850 2009  to  Wed Mar 18 02:33:57.914 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 199  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:01.536 2009  to  Wed Mar 18 02:34:01.600 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 200  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:05.223 2009  to  Wed Mar 18 02:34:05.287 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 201  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:08.911 2009  to  Wed Mar 18 02:34:08.977 2009   (  0.07) secs
                     timeout occured waiting for a guide image

 202  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:12.598 2009  to  Wed Mar 18 02:34:12.662 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 203  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:16.284 2009  to  Wed Mar 18 02:34:16.348 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 204  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:19.970 2009  to  Wed Mar 18 02:34:20.034 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 205  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:26.074 2009  to  Wed Mar 18 02:34:26.436 2009   (  0.36) secs
                     timeout occured waiting for a guide image

 206  FAILED    GCS        interface.azcam.guider.readout                                Wed Mar 18 02:34:29.754 2009  to  Wed Mar 18 02:34:29.818 2009   (  0.06) secs
                     timeout occured waiting for a guide image

 207  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 02:59:22.443 2009  to  Wed Mar 18 03:00:37.644 2009   ( 75.20) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 208  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:00:26.038 2009  to  Wed Mar 18 03:00:37.423 2009   ( 11.39) secs
                     couldn''t find a star in any GS location.

 209  FAILED    PMC        VxInterface.close                                             Wed Mar 18 03:03:05.369 2009  to  Wed Mar 18 03:03:05.369 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 210  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 03:03:05.316 2009  to  Wed Mar 18 03:03:05.316 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 211  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:11:15.974 2009  to  Wed Mar 18 03:12:07.233 2009   ( 51.26) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 212  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:11:55.494 2009  to  Wed Mar 18 03:12:07.107 2009   ( 11.61) secs
                     couldn''t find a star in any GS location.

 213  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:12:36.930 2009  to  Wed Mar 18 03:13:24.037 2009   ( 47.11) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 214  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:13:12.738 2009  to  Wed Mar 18 03:13:23.793 2009   ( 11.05) secs
                     couldn''t find a star in any GS location.

 215  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:25:42.418 2009  to  Wed Mar 18 03:26:35.474 2009   ( 53.06) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 216  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:26:23.803 2009  to  Wed Mar 18 03:26:35.354 2009   ( 11.55) secs
                     couldn''t find a star in any GS location.

 217  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 03:36:09.046 2009  to  Wed Mar 18 03:37:02.387 2009   ( 53.34) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 218  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 03:36:50.992 2009  to  Wed Mar 18 03:37:02.171 2009   ( 11.18) secs
                     couldn''t find a star in any GS location.

 219  STARTUP   GCS        startup                                                       Wed Mar 18 03:57:01.422 2009  to  Wed Mar 18 03:57:01.422 2009   (  0.00) secs
                     left GCS subsystem started

 220  FAILED    PMC        VxInterface.selectTimeout                                     Wed Mar 18 03:58:02.813 2009  to  Wed Mar 18 03:58:02.813 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 221  FAILED    PMC        thermal.badReceive                                            Wed Mar 18 03:58:02.917 2009  to  Wed Mar 18 03:58:02.917 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 222  FAILED    PMC        VxInterface.packetReadError                                   Wed Mar 18 03:58:02.865 2009  to  Wed Mar 18 03:58:02.865 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 223  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 04:05:22.161 2009  to  Wed Mar 18 04:06:19.776 2009   ( 57.61) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 224  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 04:06:08.332 2009  to  Wed Mar 18 04:06:19.548 2009   ( 11.22) secs
                     couldn''t find a star in any GS location.

 225  FAILED    PMC        VxInterface.close                                             Wed Mar 18 04:11:45.547 2009  to  Wed Mar 18 04:11:45.547 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 226  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 04:11:45.494 2009  to  Wed Mar 18 04:11:45.494 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 227  FAILED    PMC        VxInterface.close                                             Wed Mar 18 04:48:21.915 2009  to  Wed Mar 18 04:48:21.915 2009   (  0.00) secs
                     left PMC ServoLoop closing network connection

 228  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 04:48:21.863 2009  to  Wed Mar 18 04:48:21.863 2009   (  0.00) secs
                     left PMC ServoLoop length error: expected 544, got 96

 229  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:22:17.671 2009  to  Wed Mar 18 05:22:18.874 2009   (  1.20) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 230  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:22:18.019 2009  to  Wed Mar 18 05:22:18.826 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 22.035, -496.093, focus: -88.5537 :AGW1: Requested position is Out of Range

 231  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:23:49.835 2009  to  Wed Mar 18 05:23:50.733 2009   (  0.90) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 232  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:23:50.120 2009  to  Wed Mar 18 05:23:50.676 2009   (  0.56) secs
                     couldn''t move probe to position (SFP) 3.85268, -477.568, focus: -79.6 :AGW1: Requested position is Out of Range

 233  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:25:17.079 2009  to  Wed Mar 18 05:25:18.525 2009   (  1.45) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 234  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:25:17.411 2009  to  Wed Mar 18 05:25:18.471 2009   (  1.06) secs
                     couldn''t move probe to position (SFP) 40.2421, -514.667, focus: -98.1836 :AGW1: Requested position is Out of Range

 235  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 05:37:48.513 2009  to  Wed Mar 18 05:37:48.513 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 236  FAILED    PMC        VxInterface.close                                             Wed Mar 18 05:37:48.565 2009  to  Wed Mar 18 05:37:48.565 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 237  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 05:41:56.776 2009  to  Wed Mar 18 05:41:56.776 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 238  FAILED    PMC        VxInterface.close                                             Wed Mar 18 05:41:56.828 2009  to  Wed Mar 18 05:41:56.828 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 239  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:44:19.152 2009  to  Wed Mar 18 05:44:20.623 2009   (  1.47) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 240  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:44:19.759 2009  to  Wed Mar 18 05:44:20.568 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 41.4432, -515.886, focus: -98.8384 :AGW1: Requested position is Out of Range

 241  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:45:49.009 2009  to  Wed Mar 18 05:45:50.241 2009   (  1.23) secs
                     offsetGuiding command failed as probe couldn''t be moved on new position: AGW1: Requested position is Out of Range

 242  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:45:49.380 2009  to  Wed Mar 18 05:45:50.187 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 23.2654, -534.457, focus: -107.704 :AGW1: Requested position is Out of Range

 243  FAILED    GCS        command.offsetGuiding                                         Wed Mar 18 05:47:15.593 2009  to  Wed Mar 18 05:47:17.326 2009   (  1.73) secs
                    

 244  FAILED    GCS        interface.agw.setProbePosition                                Wed Mar 18 05:47:16.380 2009  to  Wed Mar 18 05:47:17.187 2009   (  0.81) secs
                     couldn''t move probe to position (SFP) 59.5953, -497.361, focus: -90.6461 :AGW1: Requested position is Out of Range

 245  FAILED    IIF        command.offset                                                Wed Mar 18 05:48:41.215 2009  to  Wed Mar 18 05:56:06.976 2009   (445.76) secs
                     IIF Offset command wait for telescope started for left LUCIFER
                     IIF Offset alert for left LUCIFER: Invalid buffer: RPCERROR
                     IIF Offset command failed for left LUCIFER from IIF

 246  STARTUP   GCS        startup                                                       Wed Mar 18 05:56:16.909 2009  to  Wed Mar 18 05:56:16.909 2009   (  0.00) secs
                     left GCS subsystem started

 247  FAILED    PMC        VxInterface.lengthError                                       Wed Mar 18 06:00:09.611 2009  to  Wed Mar 18 06:00:09.611 2009   (  0.00) secs
                     left PMC Hardpoint length error: expected 304, got 96

 248  FAILED    PMC        VxInterface.close                                             Wed Mar 18 06:00:09.696 2009  to  Wed Mar 18 06:00:09.696 2009   (  0.00) secs
                     left PMC Hardpoint closing network connection

 249  FAILED    IIF        command.offset                                                Wed Mar 18 06:00:42.292 2009  to  Wed Mar 18 06:05:10.137 2009   (267.85) secs
                     IIF Offset command wait for telescope started for left LUCIFER
                     IIF Offset alert for left LUCIFER: Invalid buffer: RPCERROR
                     IIF Offset command failed for left LUCIFER from IIF

 250  STARTUP   GCS        startup                                                       Wed Mar 18 06:07:29.422 2009  to  Wed Mar 18 06:07:29.422 2009   (  0.00) secs
                     left GCS subsystem started

 251  FAILED    IIF        command.preset.(ACTIVE)                                       Wed Mar 18 06:07:37.073 2009  to  Wed Mar 18 06:08:24.570 2009   ( 47.50) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: full CCD readout is fully saturated. Processing impossible.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 252  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Wed Mar 18 06:08:24.395 2009  to  Wed Mar 18 06:08:24.447 2009   (  0.05) secs
                     full CCD readout is fully saturated. Processing impossible.

 253  FAILED    IIF        command.offset                                                Wed Mar 18 06:08:24.997 2009  to  Wed Mar 18 06:08:25.229 2009   (  0.23) secs
                     IIF Offset command started for left LUCIFER from IIF
                     IIF Offset alert for left LUCIFER: guiding is not active
                     IIF Offset command failed for left LUCIFER from IIF

 254  FAILED    GCS        command.pauseGuiding                                          Wed Mar 18 06:08:25.057 2009  to  Wed Mar 18 06:08:25.097 2009   (  0.04) secs
                     guiding is not active

 255  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Wed Mar 18 06:23:25.211 2009  to  Wed Mar 18 06:23:25.211 2009   (  0.00) secs
                     Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 256  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Wed Mar 18 06:23:25.809 2009  to  Wed Mar 18 06:23:25.809 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 257  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Wed Mar 18 06:23:27.214 2009  to  Wed Mar 18 06:23:27.214 2009   (  0.00) secs
                     Cannot set all brakes or release all brakes.

 258  FAILED    PMC        VxInterface.selectTimeout                                     Wed Mar 18 06:44:43.121 2009  to  Wed Mar 18 06:44:43.121 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 259  FAILED    PMC        VxInterface.packetReadError                                   Wed Mar 18 06:44:43.174 2009  to  Wed Mar 18 06:44:43.174 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 260  FAILED    PMC        thermal.badReceive                                            Wed Mar 18 06:44:43.226 2009  to  Wed Mar 18 06:44:43.226 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

**********************************************************
    Reporting period ending:   Wed Mar 18 06:55:56.963 2009
********************************************************************************************************