You are here: Foswiki>Software Web>TCSSWReportFile_090315 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Mar 15 2009 to Mar 16 2009
 
    Reporting period beginning:   Sun Mar 15 17:57:02.416 2009
    Reporting period ending:      Mon Mar 16 06:57:58.028 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.MEncoders.earlyStrobe,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.abort . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          5          5                      
                                                                       0.00    0.05    0.05    0.05
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .   15.41    8.87    0.00   45.15    66.7 %         12          8          4           
                                                                      18.65   11.13    0.44   45.15

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:28:39.423 2009  to  Sun Mar 15 18:29:03.790 2009   ( 24.37) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:28:39.434 2009  to  Sun Mar 15 18:28:40.020 2009   (  0.59) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

   3  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:29:16.541 2009  to  Sun Mar 15 18:29:17.773 2009   (  1.23) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   4  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:29:57.978 2009  to  Mon Mar 16 04:30:03.233 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LUCIFER at bentGregorianFront focus

   5  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:30:03.233 2009  to  Mon Mar 16 04:30:05.634 2009   (  2.40) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   6  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:30:22.315 2009  to  Mon Mar 16 04:30:22.315 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left LUCIFER at bentGregorianFront focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   12.04   43.80   30.69   54.36   100.0 %          3          3                      
                                                                      12.04   43.80   30.69   54.36
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   15.96   66.46   17.68  106.02    78.1 %         64         46         14          4
                                                                      13.25   67.14   41.50  104.93
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    9.66    5.32    1.05   47.14    99.4 %        175        174                      
                                                                       9.66    5.32    1.05   47.14
     command.preset.(GUIDE) . . . . . . . . . . . . . . . . . . . .   47.47   56.94    0.00  425.24    81.0 %         84         63         16          5      abort =     1
                                                                      16.66   57.84   41.26  148.05
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   20.62    6.84    1.05  218.46   100.0 %        165        165                      
                                                                      20.62    6.84    1.05  218.46
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   49.15   80.08    0.72  266.33    93.1 %         29         26          2          1
                                                                      48.17   82.02   25.01  266.33
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    1.23    7.99    5.03   11.72   100.0 %        135        135                      
                                                                       1.23    7.99    5.03   11.72

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2
     trackMode. . . . . . . . . . . . . . . . . . . . . . . . . . .                             7

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 15 18:43:47.875 2009  to  Sun Mar 15 18:43:48.597 2009   (  0.72) secs
                     IIF Preset command started for left LUCIFER mode TRACK from IIF
                     IIF Preset alert for left LUCIFER mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 Az: 3.612356786104244e-01 El: -4.154021225526930e-01
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   2  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 15 18:44:59.070 2009  to  Sun Mar 15 18:46:48.145 2009   (109.08) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for left LUCIFER mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

   3  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 18:57:05.302 2009  to  Sun Mar 15 18:58:07.099 2009   ( 61.80) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   4  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 18:59:41.909 2009  to  Sun Mar 15 19:00:36.527 2009   ( 54.62) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   5  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 21:59:09.368 2009  to  Sun Mar 15 22:00:11.247 2009   ( 61.88) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   6  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:00:30.449 2009  to  Sun Mar 15 22:01:25.860 2009   ( 55.41) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   7  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:17:21.795 2009  to  Sun Mar 15 22:18:45.896 2009   ( 84.10) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 4233 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   8  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:20:06.149 2009  to  Sun Mar 15 22:21:25.371 2009   ( 79.22) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

   9  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:41:14.569 2009  to  Sun Mar 15 22:41:52.821 2009   ( 38.25) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  10  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:50:53.600 2009  to  Sun Mar 15 22:52:07.612 2009   ( 74.01) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  11  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:53:01.363 2009  to  Sun Mar 15 22:53:57.484 2009   ( 56.12) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  12  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 23:12:39.075 2009  to  Sun Mar 15 23:14:25.091 2009   (106.02) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode ACTIVE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 247
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  13  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:23:04.071 2009  to  Mon Mar 16 00:24:42.028 2009   ( 97.96) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  14  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:37:25.505 2009  to  Mon Mar 16 00:38:31.786 2009   ( 66.28) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  15  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:38:57.655 2009  to  Mon Mar 16 00:39:43.475 2009   ( 45.82) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  16  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:44:01.431 2009  to  Mon Mar 16 00:44:19.109 2009   ( 17.68) secs
                     IIF Preset command started for left LUCIFER mode ACTIVE from IIF
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGw command status: AGW1: Requested position is Out of Range
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGw command status: AGW1: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 175.595, 15.5391, 15.8079 mm.
                     IIF Preset alert for left LUCIFER mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  17  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:48:30.862 2009  to  Mon Mar 16 01:49:27.795 2009   ( 56.93) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  18  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:51:05.383 2009  to  Mon Mar 16 01:51:41.687 2009   ( 36.30) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  19  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:54:47.411 2009  to  Mon Mar 16 01:55:47.198 2009   ( 59.79) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  20  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:58:00.431 2009  to  Mon Mar 16 01:59:29.307 2009   ( 88.88) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 35
                     IIF Preset alert for left LUCIFER mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  21  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:08:49.858 2009  to  Mon Mar 16 02:09:52.794 2009   ( 62.94) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  22  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:23:43.005 2009  to  Mon Mar 16 02:24:14.011 2009   ( 31.01) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: IIF Preset command aborted for left LUCIFER mode GUIDE from IIF
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  23  SEQERROR  IIF        command.preset.elevationWait                                  Mon Mar 16 02:24:01.829 2009  to  Mon Mar 16 02:25:16.254 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for left LUCIFER

  24  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:24:29.581 2009  to  Mon Mar 16 02:24:31.102 2009   (  1.52) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  25  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:04:15.565 2009  to  Mon Mar 16 04:07:50.195 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

  26  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:07:50.195 2009  to  Mon Mar 16 04:08:05.814 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

  27  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:08:05.814 2009  to  Mon Mar 16 04:11:57.719 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

  28  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:11:57.719 2009  to  Mon Mar 16 04:17:15.516 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

  29  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:17:15.516 2009  to  Mon Mar 16 04:24:20.759 2009   (425.24) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset alert for left LUCIFER mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  30  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.802 2009  to  Mon Mar 16 04:24:20.802 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  31  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.814 2009  to  Mon Mar 16 04:24:20.814 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  32  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.878 2009  to  Mon Mar 16 04:24:20.878 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  33  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.888 2009  to  Mon Mar 16 04:24:20.888 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  34  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:28:32.077 2009  to  Mon Mar 16 04:28:54.896 2009   ( 22.82) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  35  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:41:58.004 2009  to  Mon Mar 16 04:42:25.827 2009   ( 27.82) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  36  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 05:17:50.396 2009  to  Mon Mar 16 05:18:10.330 2009   ( 19.93) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGw command status: AGW1: Axes had not been homed, yet
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.436301, 132.256, 22.4097 mm.
                     IIF Preset alert for left LUCIFER mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

  37  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 05:20:06.300 2009  to  Mon Mar 16 05:20:27.971 2009   ( 21.67) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGw command status: AGW1: Axes had not been homed, yet
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -0.321467, -0.0491577, 30.9874 mm.
                     IIF Preset alert for left LUCIFER mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  3864                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  7728                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      38                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       8
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .      10

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    9.26   20.94    0.00   53.32    91.1 %        135        130         12           
                                                                       8.32   19.92    0.00   43.98
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    2.32    1.59    0.00   16.09    95.9 %        135        148          6           
                                                                       1.25    1.29    0.00   11.02
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    1.98    7.82    4.50    9.62   100.0 %          6          6                      
                                                                       1.98    7.82    4.50    9.62
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %        215                                 
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .    0.10   51.50   51.40   51.64    98.1 %        215                     4           
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %        430                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %        215                                 
                                                                                                   
     command.parkActiveProbe. . . . . . . . . . . . . . . . . . . .                                   100.0 %         28                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    5.15    3.70    0.06    7.34   100.0 %          2          2                      
                                                                       5.15    3.70    0.06    7.34
     command.setGuidestarList . . . . . . . . . . . . . . . . . . .    8.82   24.06    0.00   65.25    98.0 %        150        150          3           
                                                                       8.87   24.17    0.00   65.25
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .    4.36    6.02    2.86   12.21    99.1 %        428                     4           
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          3                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .    0.04    0.06    0.04    0.33   100.0 %         50         50                      
                                                                       0.04    0.06    0.04    0.33
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .    0.01    0.06    0.05    0.06   100.0 %          3          3                      
                                                                       0.01    0.06    0.05    0.06
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .    1.31    0.86    0.11    9.61    59.5 %        190        113                      
                                                                       1.31    0.86    0.11    9.61
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .    1.43    0.86    0.00    6.92    98.0 %         51         50          1           
                                                                       1.14    0.73    0.00    5.40
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    5.78   13.81    0.80   56.49    98.0 %        150        147          3           
                                                                       5.73   13.94    7.10   56.49
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    1.28    2.85    0.67    8.18    98.1 %       4090       4012                        interrupted =    77
                                                                       1.28    2.85    0.67    8.18
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .   11.17   35.08   32.32   82.41    95.5 %        198        158          9             interrupted =    31
                                                                       0.07   32.42   32.32   32.58
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.05    0.20    0.15    0.41   100.0 %        150        150                      
                                                                       0.05    0.20    0.15    0.41
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    1.69    0.27    0.13   62.63   100.0 %       3698       3698                        interrupted =     4
                                                                       1.69    0.27    0.13   62.63
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.43    2.00    1.18    2.79   100.0 %        130        130                      
                                                                       0.43    2.00    1.18    2.79
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .   35.53   21.37    7.98  360.11   100.0 %        149        149                      
                                                                      35.53   21.37    7.98  360.11
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    1.41    7.47    5.69   22.31   100.0 %        156        156                      
                                                                       1.41    7.47    5.69   22.31

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .     130                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .      50                      
 *** guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                 31        216
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .      50                      
     guidethread.stopped. . . . . . . . . . . . . . . . . . . . . .     128                      
     wfsthread.warning. . . . . . . . . . . . . . . . . . . . . . .                             2

GCS Events of Interest

   1  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 18:57:50.790 2009  to  Sun Mar 15 18:58:06.883 2009   ( 16.09) secs
                     couldn''t find a star in any GS location.

   2  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 19:00:21.853 2009  to  Sun Mar 15 19:00:36.164 2009   ( 14.31) secs
                     couldn''t find a star in any GS location.

   3  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:23:43.911 2009  to  Sun Mar 15 21:25:05.291 2009   ( 81.38) secs
                     timeout waiting to receive an image

   4  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:25:17.022 2009  to  Sun Mar 15 21:26:38.444 2009   ( 81.42) secs
                     timeout waiting to receive an image

   5  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:26:44.977 2009  to  Sun Mar 15 21:28:06.366 2009   ( 81.39) secs
                     timeout waiting to receive an image

   6  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:28:12.677 2009  to  Sun Mar 15 21:29:34.092 2009   ( 81.42) secs
                     timeout waiting to receive an image

   7  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 21:30:08.651 2009  to  Sun Mar 15 21:30:08.651 2009   (  0.00) secs
                     left GCS ShutDown Command Started

   8  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 21:30:09.563 2009  to  Sun Mar 15 21:30:09.563 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

   9  STARTUP   GCS        startup                                                       Sun Mar 15 21:30:32.009 2009  to  Sun Mar 15 21:30:32.009 2009   (  0.00) secs
                     left GCS subsystem started

  10  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 21:59:49.206 2009  to  Sun Mar 15 22:00:10.944 2009   ( 21.74) secs
                     guiding was not stable within 6 cycles

  11  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:01:00.921 2009  to  Sun Mar 15 22:01:25.524 2009   ( 24.60) secs
                     guiding was not stable within 6 cycles

  12  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:18:09.343 2009  to  Sun Mar 15 22:18:45.575 2009   ( 36.23) secs
                     guiding was not stable within 6 cycles

  13  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:18:39.108 2009  to  Sun Mar 15 22:18:39.108 2009   (  0.00) secs
                     no guide star found

  14  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:18:43.998 2009  to  Sun Mar 15 22:18:43.998 2009   (  0.00) secs
                     no guide star found

  15  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:20:31.916 2009  to  Sun Mar 15 22:21:25.084 2009   ( 53.17) secs
                     guiding was not stable within 6 cycles

  16  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:04.007 2009  to  Sun Mar 15 22:21:04.007 2009   (  0.00) secs
                     no guide star found

  17  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:08.834 2009  to  Sun Mar 15 22:21:08.834 2009   (  0.00) secs
                     no guide star found

  18  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:13.709 2009  to  Sun Mar 15 22:21:13.709 2009   (  0.00) secs
                     no guide star found

  19  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:18.542 2009  to  Sun Mar 15 22:21:18.542 2009   (  0.00) secs
                     no guide star found

  20  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:23.401 2009  to  Sun Mar 15 22:21:23.401 2009   (  0.00) secs
                     no guide star found

  21  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:51:41.030 2009  to  Sun Mar 15 22:52:07.352 2009   ( 26.32) secs
                     guiding was not stable within 6 cycles

  22  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 22:53:45.909 2009  to  Sun Mar 15 22:53:57.363 2009   ( 11.45) secs
                     couldn''t find a star in any GS location.

  23  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 22:59:07.727 2009  to  Sun Mar 15 23:00:29.465 2009   ( 81.74) secs
                     timeout waiting to receive an image

  24  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:00:38.336 2009  to  Sun Mar 15 23:02:00.016 2009   ( 81.68) secs
                     timeout waiting to receive an image

  25  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:02:08.791 2009  to  Sun Mar 15 23:03:31.196 2009   ( 82.41) secs
                     timeout waiting to receive an image

  26  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:03:42.933 2009  to  Sun Mar 15 23:05:05.169 2009   ( 82.24) secs
                     timeout waiting to receive an image

  27  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:05:12.462 2009  to  Sun Mar 15 23:06:34.402 2009   ( 81.94) secs
                     timeout waiting to receive an image

  28  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 23:07:44.500 2009  to  Sun Mar 15 23:07:44.500 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  29  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 23:07:45.726 2009  to  Sun Mar 15 23:07:45.726 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  30  STARTUP   GCS        startup                                                       Sun Mar 15 23:08:13.259 2009  to  Sun Mar 15 23:08:13.259 2009   (  0.00) secs
                     left GCS subsystem started

  31  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 23:13:40.789 2009  to  Sun Mar 15 23:14:24.641 2009   ( 43.85) secs
                     guiding was not stable within 6 cycles

  32  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:11.970 2009  to  Sun Mar 15 23:14:11.970 2009   (  0.00) secs
                     no guide star found

  33  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:17.261 2009  to  Sun Mar 15 23:14:17.261 2009   (  0.00) secs
                     no guide star found

  34  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:22.798 2009  to  Sun Mar 15 23:14:22.798 2009   (  0.00) secs
                     no guide star found

  35  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:15:48.560 2009  to  Sun Mar 15 23:15:48.560 2009   (  0.00) secs
                     no guide star found

  36  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:15:57.585 2009  to  Sun Mar 15 23:15:57.585 2009   (  0.00) secs
                     no guide star found

  37  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:32.307 2009  to  Sun Mar 15 23:16:32.307 2009   (  0.00) secs
                     no guide star found

  38  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:38.147 2009  to  Sun Mar 15 23:16:38.147 2009   (  0.00) secs
                     no guide star found

  39  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:43.812 2009  to  Sun Mar 15 23:16:43.812 2009   (  0.00) secs
                     no guide star found

  40  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:49.238 2009  to  Sun Mar 15 23:16:49.238 2009   (  0.00) secs
                     no guide star found

  41  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:54.747 2009  to  Sun Mar 15 23:16:54.747 2009   (  0.00) secs
                     no guide star found

  42  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:00.357 2009  to  Sun Mar 15 23:17:00.357 2009   (  0.00) secs
                     no guide star found

  43  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:05.665 2009  to  Sun Mar 15 23:17:05.665 2009   (  0.00) secs
                     no guide star found

  44  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:11.156 2009  to  Sun Mar 15 23:17:11.156 2009   (  0.00) secs
                     no guide star found

  45  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:16.534 2009  to  Sun Mar 15 23:17:16.534 2009   (  0.00) secs
                     no guide star found

  46  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:22.009 2009  to  Sun Mar 15 23:17:22.009 2009   (  0.00) secs
                     no guide star found

  47  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:27.420 2009  to  Sun Mar 15 23:17:27.420 2009   (  0.00) secs
                     no guide star found

  48  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:32.924 2009  to  Sun Mar 15 23:17:32.924 2009   (  0.00) secs
                     no guide star found

  49  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 00:24:10.223 2009  to  Mon Mar 16 00:24:41.740 2009   ( 31.52) secs
                     guiding was not stable within 6 cycles

  50  FAILED    GCS        command.stopWFsensing                                         Mon Mar 16 00:34:31.810 2009  to  Mon Mar 16 00:34:38.732 2009   (  6.92) secs
                     WFS loop didn''t stop within timeout.

  51  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 00:38:08.624 2009  to  Mon Mar 16 00:38:31.498 2009   ( 22.87) secs
                     guiding was not stable within 6 cycles

  52  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 00:39:31.226 2009  to  Mon Mar 16 00:39:43.230 2009   ( 12.00) secs
                     couldn''t find a star in any GS location.

  53  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 00:44:02.869 2009  to  Mon Mar 16 00:44:18.828 2009   ( 15.96) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  54  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 00:44:17.968 2009  to  Mon Mar 16 00:44:18.773 2009   (  0.80) secs
                     couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGW1: Requested position is Out of Range

  55  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 01:31:31.456 2009  to  Mon Mar 16 01:31:31.456 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  56  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 01:31:32.700 2009  to  Mon Mar 16 01:31:32.700 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  57  STARTUP   GCS        startup                                                       Mon Mar 16 01:31:43.994 2009  to  Mon Mar 16 01:31:43.994 2009   (  0.00) secs
                     left GCS subsystem started

  58  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:49:05.463 2009  to  Mon Mar 16 01:49:27.503 2009   ( 22.04) secs
                     guiding was not stable within 6 cycles

  59  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 01:51:41.334 2009  to  Mon Mar 16 01:51:41.507 2009   (  0.17) secs
                    

  60  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 01:51:41.560 2009  to  Mon Mar 16 01:51:41.560 2009   (  0.00) secs
                     couldn''t find a star in any GS location.

  61  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:55:25.061 2009  to  Mon Mar 16 01:55:46.914 2009   ( 21.85) secs
                     guiding was not stable within 6 cycles

  62  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:58:35.542 2009  to  Mon Mar 16 01:59:28.859 2009   ( 53.32) secs
                     guiding was not stable within 6 cycles

  63  FAILED    GCS        guidethread.warning                                           Mon Mar 16 01:59:14.743 2009  to  Mon Mar 16 01:59:14.743 2009   (  0.00) secs
                     no guide star found

  64  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 02:09:26.514 2009  to  Mon Mar 16 02:09:52.510 2009   ( 26.00) secs
                     guiding was not stable within 6 cycles

  65  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 02:23:00.583 2009  to  Mon Mar 16 02:23:00.583 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  66  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 02:23:01.714 2009  to  Mon Mar 16 02:23:01.714 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  67  STARTUP   GCS        startup                                                       Mon Mar 16 02:23:09.512 2009  to  Mon Mar 16 02:23:09.512 2009   (  0.00) secs
                     left GCS subsystem started

  68  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:51:11.016 2009  to  Mon Mar 16 03:51:23.223 2009   ( 12.21) secs
                     could not set exposure time with AzCam server

  69  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 03:51:23.384 2009  to  Mon Mar 16 03:52:14.786 2009   ( 51.40) secs
                     AzCam server timed out waiting for full CCD readout

  70  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:52:14.871 2009  to  Mon Mar 16 03:52:17.949 2009   (  3.08) secs
                     could not set exposure time with AzCam server

  71  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:52:26.202 2009  to  Mon Mar 16 03:52:32.135 2009   (  5.93) secs
                     could not set exposure time with AzCam server

  72  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 03:52:32.310 2009  to  Mon Mar 16 03:53:23.817 2009   ( 51.51) secs
                     AzCam server timed out waiting for full CCD readout

  73  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 03:53:27.761 2009  to  Mon Mar 16 03:53:27.761 2009   (  0.00) secs
                     left GCS ShutDown Command Started

  74  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 03:53:29.640 2009  to  Mon Mar 16 03:53:29.640 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

  75  STARTUP   GCS        startup                                                       Mon Mar 16 03:53:57.192 2009  to  Mon Mar 16 03:53:57.192 2009   (  0.00) secs
                     left GCS subsystem started

  76  STARTUP   GCS        startup                                                       Mon Mar 16 04:06:56.272 2009  to  Mon Mar 16 04:06:56.272 2009   (  0.00) secs
                     left GCS subsystem started

  77  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 05:17:51.814 2009  to  Mon Mar 16 05:18:10.060 2009   ( 18.25) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  78  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 05:18:00.140 2009  to  Mon Mar 16 05:18:10.008 2009   (  9.87) secs
                     couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGW1: Axes had not been homed, yet

  79  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 05:20:07.367 2009  to  Mon Mar 16 05:20:27.696 2009   ( 20.33) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

  80  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 05:20:14.990 2009  to  Mon Mar 16 05:20:27.641 2009   ( 12.65) secs
                     couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGW1: Axes had not been homed, yet

  81  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 05:25:30.895 2009  to  Mon Mar 16 05:26:22.532 2009   ( 51.64) secs
                     AzCam server timed out waiting for full CCD readout

  82  STARTUP   GCS        startup                                                       Mon Mar 16 05:26:50.777 2009  to  Mon Mar 16 05:26:50.777 2009   (  0.00) secs
                     left GCS subsystem started

  83  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 05:57:28.871 2009  to  Mon Mar 16 05:57:31.730 2009   (  2.86) secs
                     could not set exposure time with AzCam server

  84  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 05:57:31.887 2009  to  Mon Mar 16 05:58:23.357 2009   ( 51.47) secs
                     AzCam server timed out waiting for full CCD readout

  85  STARTUP   GCS        startup                                                       Mon Mar 16 05:58:40.650 2009  to  Mon Mar 16 05:58:40.650 2009   (  0.00) secs
                     left GCS subsystem started
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      22                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       7                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                603           
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  5           
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 11           
     MCSPU.RTracker.badPoly . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             3
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       9                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            30
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            13
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      32                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      98                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           173
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             9
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      81                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       4                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      64                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      30                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      26                      
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      62                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Rotators.rHold . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.MEncoders.earlyStrobe. . . . . . . . . . . . . . . . . .                             1
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             2
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     357                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     270                      
     MCSPU.RTracker.computeSlewPath . . . . . . . . . . . . . . . .     306                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .     178                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     357                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     179                      
     MCSPU.Rotators/rotatorOnSourceChange . . . . . . . . . . . . .     227                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1950                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     638                      
     MCSPU.RTracker.trackLimitWarning . . . . . . . . . . . . . . .       7                      
     MCSPU.TPlcDevice.readError . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.brakeCmdTimeOut. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       8                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       4                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 16           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.ampsOnAckTimeOut . . . . . . . . . . . . . . . .                  6           
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  2           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Main.termination . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      38                      
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:02.416 2009  to  Sun Mar 15 17:57:02.416 2009   (  0.00) secs
                     EL bad poly no. 72872: BAD Poly: EL = -4.691297e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:05.401 2009  to  Sun Mar 15 17:57:05.401 2009   (  0.00) secs
                     EL bad poly no. 72927: BAD Poly: EL = -4.689845e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:08.426 2009  to  Sun Mar 15 17:57:08.426 2009   (  0.00) secs
                     EL bad poly no. 72981: BAD Poly: EL = -4.688373e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:11.428 2009  to  Sun Mar 15 17:57:11.428 2009   (  0.00) secs
                     EL bad poly no. 73035: BAD Poly: EL = -4.686912e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:14.472 2009  to  Sun Mar 15 17:57:14.472 2009   (  0.00) secs
                     EL bad poly no. 73090: BAD Poly: EL = -4.685431e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:17.501 2009  to  Sun Mar 15 17:57:17.501 2009   (  0.00) secs
                     EL bad poly no. 73144: BAD Poly: EL = -4.683956e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:20.573 2009  to  Sun Mar 15 17:57:20.573 2009   (  0.00) secs
                     EL bad poly no. 73199: BAD Poly: EL = -4.682460e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:23.620 2009  to  Sun Mar 15 17:57:23.620 2009   (  0.00) secs
                     EL bad poly no. 73253: BAD Poly: EL = -4.680977e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:26.633 2009  to  Sun Mar 15 17:57:26.633 2009   (  0.00) secs
                     EL bad poly no. 73306: BAD Poly: EL = -4.679510e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:29.666 2009  to  Sun Mar 15 17:57:29.666 2009   (  0.00) secs
                     EL bad poly no. 73360: BAD Poly: EL = -4.678032e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:32.704 2009  to  Sun Mar 15 17:57:32.704 2009   (  0.00) secs
                     EL bad poly no. 73413: BAD Poly: EL = -4.676552e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:35.771 2009  to  Sun Mar 15 17:57:35.771 2009   (  0.00) secs
                     EL bad poly no. 73471: BAD Poly: EL = -4.675058e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:38.800 2009  to  Sun Mar 15 17:57:38.800 2009   (  0.00) secs
                     EL bad poly no. 73531: BAD Poly: EL = -4.673582e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:41.824 2009  to  Sun Mar 15 17:57:41.824 2009   (  0.00) secs
                     EL bad poly no. 73591: BAD Poly: EL = -4.672108e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:44.833 2009  to  Sun Mar 15 17:57:44.833 2009   (  0.00) secs
                     EL bad poly no. 73647: BAD Poly: EL = -4.670641e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:47.883 2009  to  Sun Mar 15 17:57:47.883 2009   (  0.00) secs
                     EL bad poly no. 73702: BAD Poly: EL = -4.669154e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:50.908 2009  to  Sun Mar 15 17:57:50.908 2009   (  0.00) secs
                     EL bad poly no. 73757: BAD Poly: EL = -4.667680e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:53.942 2009  to  Sun Mar 15 17:57:53.942 2009   (  0.00) secs
                     EL bad poly no. 73815: BAD Poly: EL = -4.666200e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:56.977 2009  to  Sun Mar 15 17:57:56.977 2009   (  0.00) secs
                     EL bad poly no. 73875: BAD Poly: EL = -4.664720e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:00.001 2009  to  Sun Mar 15 17:58:00.001 2009   (  0.00) secs
                     EL bad poly no. 73934: BAD Poly: EL = -4.663245e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:02.987 2009  to  Sun Mar 15 17:58:02.987 2009   (  0.00) secs
                     EL bad poly no. 73993: BAD Poly: EL = -4.661788e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:06.008 2009  to  Sun Mar 15 17:58:06.008 2009   (  0.00) secs
                     EL bad poly no. 74051: BAD Poly: EL = -4.660315e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:09.019 2009  to  Sun Mar 15 17:58:09.019 2009   (  0.00) secs
                     EL bad poly no. 74110: BAD Poly: EL = -4.658845e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:12.032 2009  to  Sun Mar 15 17:58:12.032 2009   (  0.00) secs
                     EL bad poly no. 74168: BAD Poly: EL = -4.657375e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:15.046 2009  to  Sun Mar 15 17:58:15.046 2009   (  0.00) secs
                     EL bad poly no. 74226: BAD Poly: EL = -4.655905e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun Mar 15 18:07:18.198 2009  to  Sun Mar 15 18:07:18.198 2009   (  0.00) secs
                     LFBG bad poly no. 2: t0 is 2.500933e+00 seconds in the past!

  27  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:07:18.189 2009  to  Sun Mar 15 18:07:18.189 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:07:18.192 2009  to  Sun Mar 15 18:07:18.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:13:01.724 2009  to  Sun Mar 15 18:13:01.724 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:13:01.726 2009  to  Sun Mar 15 18:13:01.726 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun Mar 15 18:13:01.733 2009  to  Sun Mar 15 18:13:01.733 2009   (  0.00) secs
                     LFBG bad poly no. 3: t0 is 2.053242e+00 seconds in the past!

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:27:29.313 2009  to  Sun Mar 15 18:27:29.313 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:27:30.383 2009  to  Sun Mar 15 18:27:30.383 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  34  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Mon Mar 16 00:39:32.093 2009  to  Mon Mar 16 00:39:32.093 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 2 times

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:29:59.222 2009  to  Mon Mar 16 04:29:59.222 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:29:59.249 2009  to  Mon Mar 16 04:29:59.249 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  37  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Mar 16 04:30:00.251 2009  to  Mon Mar 16 04:30:00.251 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  38  FAILED    MCS.MCSPU  MCSPU.Brake.brakeCmdTimeOut                                   Mon Mar 16 04:39:34.498 2009  to  Mon Mar 16 04:39:34.498 2009   (  0.00) secs
                     EL brake command timed out. Didnt get msg back from PLC within time limit.

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:40:35.174 2009  to  Mon Mar 16 04:40:35.174 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:40:35.180 2009  to  Mon Mar 16 04:40:35.180 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  41  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 16 04:40:35.282 2009  to  Mon Mar 16 04:40:35.282 2009   (  0.00) secs
                     drive cabinet has turned on.

  42  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  43  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  44  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.292 2009  to  Mon Mar 16 04:40:36.292 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  47  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.294 2009  to  Mon Mar 16 04:40:36.294 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:42:55.494 2009  to  Mon Mar 16 04:42:55.494 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:42:55.521 2009  to  Mon Mar 16 04:42:55.521 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Mar 16 04:42:56.506 2009  to  Mon Mar 16 04:42:56.506 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  53  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:17.747 2009  to  Mon Mar 16 06:03:17.747 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  54  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:22.879 2009  to  Mon Mar 16 06:03:22.879 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  55  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:26.174 2009  to  Mon Mar 16 06:03:26.174 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  56  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:28.985 2009  to  Mon Mar 16 06:03:28.985 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  57  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:31.795 2009  to  Mon Mar 16 06:03:31.795 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  58  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Mon Mar 16 06:03:34.011 2009  to  Mon Mar 16 06:03:34.011 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

  59  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:04:12.321 2009  to  Mon Mar 16 06:04:12.321 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

  60  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 16 06:04:28.199 2009  to  Mon Mar 16 06:04:28.199 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  61  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Mon Mar 16 06:04:31.808 2009  to  Mon Mar 16 06:04:31.808 2009   (  0.00) secs
                     Main program is terminating.

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 06:05:14.501 2009  to  Mon Mar 16 06:05:14.501 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 06:05:14.504 2009  to  Mon Mar 16 06:05:14.504 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 16 06:05:14.608 2009  to  Mon Mar 16 06:05:14.608 2009   (  0.00) secs
                     drive cabinet has turned on.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.627 2009  to  Mon Mar 16 06:05:15.627 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.627 2009  to  Mon Mar 16 06:05:15.627 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.628 2009  to  Mon Mar 16 06:05:15.628 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.628 2009  to  Mon Mar 16 06:05:15.628 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  69  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.629 2009  to  Mon Mar 16 06:05:15.629 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  70  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  71  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  72  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

  73  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Mon Mar 16 06:07:44.751 2009  to  Mon Mar 16 06:07:44.751 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  74  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Mon Mar 16 06:07:44.752 2009  to  Mon Mar 16 06:07:44.752 2009   (  0.00) secs
                     A brake command failed to complete successfully.

  75  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 16 06:08:26.833 2009  to  Mon Mar 16 06:08:26.833 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

  76  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Mon Mar 16 06:08:30.535 2009  to  Mon Mar 16 06:08:30.535 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

  77  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Mon Mar 16 06:08:30.644 2009  to  Mon Mar 16 06:08:30.644 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     side[0].secondary_mirror.moveabs.command . . . . . . . . . . .    3.04    6.63    2.51   15.19   100.0 %        321        321                      
                                                                       3.04    6.63    2.51   15.19
     side[0].tertiary_mirror.adjustcurrfocalstation.command . . . .    0.81    4.77    3.40    8.21    95.4 %        174        166                      
                                                                       0.81    4.77    3.40    8.21
     side[0].tertiary_mirror.homemirror.command . . . . . . . . . .    0.00   30.37   30.37   30.37   100.0 %          1          1                      
                                                                       0.00   30.37   30.37   30.37
     side[0].tertiary_mirror.homesel.command. . . . . . . . . . . .    0.00   32.11   32.11   32.11   100.0 %          1          1                      
                                                                       0.00   32.11   32.11   32.11
     side[0].tertiary_mirror.init.command . . . . . . . . . . . . .    0.00    4.10    4.10    4.10   100.0 %          1          1                      
                                                                       0.00    4.10    4.10    4.10
     side[0].tertiary_mirror.movefocalstation.command . . . . . . .   11.47   28.43   17.46   44.07    66.7 %          6          4                      
                                                                      11.47   28.43   17.46   44.07

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.movefocalstation.failed. . . . . . . .                  2           
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             6
     side[0].tertiary_mirror.adjustcurrfocalstation.failed. . . . .                  3           

OSS Events of Interest

   1  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Sun Mar 15 18:29:17.529 2009  to  Sun Mar 15 18:34:06.527 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

   2  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Sun Mar 15 18:29:17.607 2009  to  Sun Mar 15 18:29:17.607 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

   3  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Sun Mar 15 18:30:22.375 2009  to  Sun Mar 15 18:30:22.375 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

   4  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Sun Mar 15 18:30:24.846 2009  to  Sun Mar 15 18:30:24.846 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete

   5  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Sun Mar 15 22:41:43.365 2009  to  Sun Mar 15 22:43:35.643 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   6  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Sun Mar 15 22:41:52.588 2009  to  Sun Mar 15 22:41:52.588 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out

   7  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:04:45.645 2009  to  Mon Mar 16 04:08:08.568 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   8  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:08:08.568 2009  to  Mon Mar 16 04:08:35.780 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

   9  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:08:35.780 2009  to  Mon Mar 16 04:12:51.140 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  10  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:12:51.140 2009  to  Mon Mar 16 04:17:36.680 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  11  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:17:36.680 2009  to  Mon Mar 16 04:28:51.861 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  12  STARTUP   OSS        startup                                                       Mon Mar 16 04:24:32.783 2009  to  Mon Mar 16 04:24:32.783 2009   (  0.00) secs
                     The oss was started.

  13  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:28:51.861 2009  to  Mon Mar 16 04:42:17.564 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  14  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Mon Mar 16 04:28:51.914 2009  to  Mon Mar 16 04:28:51.914 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  15  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Mon Mar 16 04:29:59.004 2009  to  Mon Mar 16 04:30:04.775 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  16  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Mon Mar 16 04:30:05.280 2009  to  Mon Mar 16 04:30:05.280 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  17  SHUTDOWN  OSS        shutdown                                                      Mon Mar 16 04:35:57.322 2009  to  Mon Mar 16 04:35:57.322 2009   (  0.00) secs
                     The oss was shut down.

  18  STARTUP   OSS        startup                                                       Mon Mar 16 04:36:17.645 2009  to  Mon Mar 16 04:36:17.645 2009   (  0.00) secs
                     The oss was started.

  19  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:42:17.564 2009  to  Mon Mar 16 04:44:12.849 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

  20  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Mon Mar 16 04:42:17.671 2009  to  Mon Mar 16 04:42:17.671 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.03    0.06    0.04    0.21   100.0 %        150        150                      
                                                                       0.03    0.06    0.04    0.21
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.02    0.06    0.03    0.39   100.0 %       3698       3698                      
                                                                       0.02    0.06    0.03    0.39
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    0.43    1.85    1.04    2.62   100.0 %        130        130                        largeUpdate =   124
                                                                       0.43    1.85    1.04    2.62
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          6          6                      
                                                                       0.00    0.05    0.05    0.05
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.05    0.04    0.06   100.0 %         16         16                      
                                                                       0.01    0.05    0.04    0.06
     telescope.command.setEquatorialTarget. . . . . . . . . . . . .    0.03    0.07    0.05    0.30    99.4 %        180        179          1           
                                                                       0.03    0.07    0.05    0.30
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.04    0.38    0.30    0.40   100.0 %          6          6                      
                                                                       0.04    0.38    0.30    0.40
     telescope.command.setPointingLog . . . . . . . . . . . . . . .    0.02    0.10    0.08    0.11   100.0 %          2          2                      
                                                                       0.02    0.10    0.08    0.11
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.20    0.55    0.29    0.86    99.4 %        179        178                      
                                                                       0.20    0.55    0.29    0.86
     telescope.command.stopPointingLog. . . . . . . . . . . . . . .    0.00    0.13    0.12    0.13   100.0 %          2          2                      
                                                                       0.00    0.13    0.12    0.13
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.04    0.03    0.00    0.08    83.3 %         12                     2           
                                                                       0.02    0.07    0.04    0.08

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      

PCS Events of Interest

   1  SHUTDOWN  PCS        shutdown                                                      Sun Mar 15 18:27:28.485 2009  to  Sun Mar 15 18:27:28.485 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

   2  FAILED    PCS        telescope.telemetryError                                      Sun Mar 15 18:27:28.566 2009  to  Sun Mar 15 18:27:28.566 2009   (  0.00) secs
                     PCS Telescope telemetry error: 2006: MySQL server has gone away

   3  STARTUP   PCS        startup                                                       Sun Mar 15 18:27:36.501 2009  to  Sun Mar 15 18:27:36.501 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

   4  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.497 2009  to  Sun Mar 15 18:28:39.562 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   5  FAILED    PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.562 2009  to  Sun Mar 15 18:28:39.607 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   6  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.670 2009  to  Sun Mar 15 18:28:39.670 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

   7  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:29:16.610 2009  to  Sun Mar 15 18:29:16.675 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

   8  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:29:16.814 2009  to  Sun Mar 15 18:29:16.814 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

   9  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:34:05.571 2009  to  Sun Mar 15 18:34:05.647 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  10  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:34:05.735 2009  to  Sun Mar 15 18:34:05.735 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  11  FAILED    PCS        telescope.command.setEquatorialTarget                         Sun Mar 15 18:43:48.424 2009  to  Sun Mar 15 18:43:48.477 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 RotMode: PARALLACTIC Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 Az: 3.612356786104244e-01 El: -4.154021225526930e-01

  12  SEQERROR  PCS        telescope.command.startTracking                               Mon Mar 16 02:24:30.255 2009  to  Mon Mar 16 02:24:58.453 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

  13  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:29:58.048 2009  to  Mon Mar 16 04:29:58.111 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  14  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:29:58.254 2009  to  Mon Mar 16 04:29:58.254 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  15  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:30:03.303 2009  to  Mon Mar 16 04:30:03.368 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  16  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:30:03.508 2009  to  Mon Mar 16 04:30:03.508 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  17  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:42:54.372 2009  to  Mon Mar 16 04:42:54.439 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  18  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:42:54.577 2009  to  Mon Mar 16 04:42:54.577 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.19    2.07    2.05    5.06   100.0 %        277        277                      
                                                                       0.19    2.07    2.05    5.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00   13.08   13.08   13.08   100.0 %          1          1                      
                                                                       0.00   13.08   13.08   13.08
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    4.93    4.26    2.06   13.08   100.0 %          5          5                      
                                                                       4.93    4.26    2.06   13.08
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    8.08    5.44    2.05   68.18    98.6 %        358        353          5           
                                                                       7.33    5.23    2.05   59.17

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     277                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             8
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 10           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      10                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:32:02.298 2009  to  Sun Mar 15 18:32:05.376 2009   (  3.08) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:45:39.708 2009  to  Sun Mar 15 18:46:47.890 2009   ( 68.18) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:47:05.352 2009  to  Sun Mar 15 18:47:07.409 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:47:08.831 2009  to  Sun Mar 15 18:47:10.888 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 19:01:37.368 2009  to  Sun Mar 15 19:02:02.469 2009   ( 25.10) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 15 19:40:52.216 2009  to  Sun Mar 15 19:40:52.216 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   7  FAILED    PMC        VxInterface.close                                             Sun Mar 15 19:40:52.268 2009  to  Sun Mar 15 19:40:52.268 2009   (  0.00) secs
                     left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 00:30:38.221 2009  to  Mon Mar 16 00:30:38.221 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Mon Mar 16 00:30:38.276 2009  to  Mon Mar 16 00:30:38.276 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 01:12:01.850 2009  to  Mon Mar 16 01:12:01.850 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Mon Mar 16 01:12:01.903 2009  to  Mon Mar 16 01:12:01.903 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 01:55:19.563 2009  to  Mon Mar 16 01:55:19.563 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  13  FAILED    PMC        VxInterface.close                                             Mon Mar 16 01:55:19.615 2009  to  Mon Mar 16 01:55:19.615 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 02:11:42.616 2009  to  Mon Mar 16 02:11:42.616 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Mon Mar 16 02:11:42.667 2009  to  Mon Mar 16 02:11:42.667 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.close                                             Mon Mar 16 03:12:54.820 2009  to  Mon Mar 16 03:12:54.820 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 03:12:54.768 2009  to  Mon Mar 16 03:12:54.768 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 04:00:17.443 2009  to  Mon Mar 16 04:00:17.443 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Mon Mar 16 04:00:17.496 2009  to  Mon Mar 16 04:00:17.496 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 04:17:38.288 2009  to  Mon Mar 16 04:17:38.288 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Mon Mar 16 04:17:38.338 2009  to  Mon Mar 16 04:17:38.338 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.close                                             Mon Mar 16 05:13:29.341 2009  to  Mon Mar 16 05:13:29.341 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 05:13:29.289 2009  to  Mon Mar 16 05:13:29.289 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  24  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 16 05:28:41.954 2009  to  Mon Mar 16 05:28:41.954 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  25  FAILED    PMC        thermal.badReceive                                            Mon Mar 16 05:28:42.058 2009  to  Mon Mar 16 05:28:42.058 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  26  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 16 05:28:42.006 2009  to  Mon Mar 16 05:28:42.006 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

  27  FAILED    PMC        VxInterface.close                                             Mon Mar 16 05:53:11.285 2009  to  Mon Mar 16 05:53:11.285 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 05:53:11.233 2009  to  Mon Mar 16 05:53:11.233 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.82   10.80    4.70   46.38   100.0 %        284        284                      
                                                                       3.82   10.80    4.70   46.38
     command.config . . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    1.47    0.63    0.26   12.68   100.0 %        180        180                      
                                                                       1.47    0.63    0.26   12.68
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    0.00   19.45   19.45   19.45   100.0 %          1          1                      
                                                                       0.00   19.45   19.45   19.45
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %         12         12                      
                                                                       0.00    0.05    0.05    0.05
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.82   10.91    4.81   46.49   100.0 %        284        284                      
                                                                       3.82   10.91    4.81   46.49
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    2.62    5.88    0.20   35.10   100.0 %        284        284                      
                                                                       2.62    5.88    0.20   35.10
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    8.08    5.58    2.18   68.32    98.6 %        358        353          5           
                                                                       7.33    5.38    2.18   59.29
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    4.92    4.39    2.17   13.20   100.0 %          5          5                      
                                                                       4.92    4.39    2.17   13.20
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00   14.31   14.31   14.31   100.0 %          1          1                      
                                                                       0.00   14.31   14.31   14.31
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.05    0.11    0.06    0.46   100.0 %       1446       1446                      
                                                                       0.05    0.11    0.06    0.46
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   17.48   17.48   17.48     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    8.53   12.07    3.29   31.37    91.7 %         12         11          1           
                                                                       7.79   10.86    3.29   31.37
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    0.00    7.31    7.31    7.31   100.0 %          1          1                      
                                                                       0.00    7.31    7.31    7.31
     primaryMirror.command.setSecondaryActiveOpticsOffload. . . . .    0.01    0.06    0.05    0.13   100.0 %        181        181                      
                                                                       0.01    0.06    0.05    0.13
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.71    2.84    2.34    3.35     0.0 %          2                     2           
                                                                                                   
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.06    0.05    0.10   100.0 %        284        284                      
                                                                       0.00    0.06    0.05    0.10
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    1.43    8.96    5.79   12.56   100.0 %        146        146                      
                                                                       1.43    8.96    5.79   12.56
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    2.99    6.89    2.65   15.93   100.0 %        321        321                      
                                                                       2.99    6.89    2.65   15.93
     secondaryMirror.command.calcActiveOpticsOffload. . . . . . . .    0.01    0.05    0.05    0.11   100.0 %        181        181                      
                                                                       0.01    0.05    0.05    0.11
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.04    0.06    0.05    0.57   100.0 %        146        146                      
                                                                       0.04    0.06    0.05    0.57
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .   30.28    7.22    0.00  404.05    95.4 %        174        166          8           
                                                                       0.85    5.07    3.63    8.57

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                187           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sun Mar 15 18:32:02.161 2009  to  Sun Mar 15 18:32:05.508 2009   (  3.35) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:32:02.214 2009  to  Sun Mar 15 18:32:05.450 2009   (  3.24) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:45:39.642 2009  to  Sun Mar 15 18:46:47.958 2009   ( 68.32) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   4  FAILED    PSF        primaryMirror.command.revert                                  Sun Mar 15 18:46:50.070 2009  to  Sun Mar 15 18:47:07.547 2009   ( 17.48) secs
                     left PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:47:05.289 2009  to  Sun Mar 15 18:47:07.486 2009   (  2.20) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   6  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sun Mar 15 18:47:08.669 2009  to  Sun Mar 15 18:47:11.010 2009   (  2.34) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:47:08.721 2009  to  Sun Mar 15 18:47:10.955 2009   (  2.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:33.865 2009  to  Sun Mar 15 18:54:33.865 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0849129e-04 3.3384562e-04 3.0190945e-03 2.2622108e-02 8.1604958e-02 2.1954775e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:34.122 2009  to  Sun Mar 15 18:54:34.122 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0849129e-04 3.3384562e-04 3.0190945e-03 2.2622108e-02 8.1604958e-02 2.1954775e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.058 2009  to  Sun Mar 15 18:54:41.058 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.316 2009  to  Sun Mar 15 18:54:41.316 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.565 2009  to  Sun Mar 15 18:54:41.565 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:47.890 2009  to  Sun Mar 15 18:54:47.890 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:48.144 2009  to  Sun Mar 15 18:54:48.144 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:01.553 2009  to  Sun Mar 15 18:55:01.553 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.0797821e-04 4.6789646e-05 3.0202270e-03 3.8274765e-02 5.4702282e-02 4.2569876e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:01.809 2009  to  Sun Mar 15 18:55:01.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.0797821e-04 4.6789646e-05 3.0202270e-03 3.8274765e-02 5.4702282e-02 4.2569876e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:11.787 2009  to  Sun Mar 15 18:55:11.787 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:12.042 2009  to  Sun Mar 15 18:55:12.042 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.105 2009  to  Sun Mar 15 18:55:13.105 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.361 2009  to  Sun Mar 15 18:55:13.361 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.616 2009  to  Sun Mar 15 18:55:13.616 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.871 2009  to  Sun Mar 15 18:55:13.871 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:16.554 2009  to  Sun Mar 15 18:55:16.554 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:16.810 2009  to  Sun Mar 15 18:55:16.810 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:30.225 2009  to  Sun Mar 15 18:55:30.225 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:30.480 2009  to  Sun Mar 15 18:55:30.480 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:32.148 2009  to  Sun Mar 15 18:55:32.148 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:32.405 2009  to  Sun Mar 15 18:55:32.405 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.065 2009  to  Sun Mar 15 18:55:33.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.321 2009  to  Sun Mar 15 18:55:33.321 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.578 2009  to  Sun Mar 15 18:55:33.578 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:35.095 2009  to  Sun Mar 15 18:55:35.095 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  33  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sun Mar 15 19:01:37.252 2009  to  Sun Mar 15 19:02:02.593 2009   ( 25.34) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  34  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 19:01:37.305 2009  to  Sun Mar 15 19:02:02.537 2009   ( 25.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  35  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Sun Mar 15 22:41:43.219 2009  to  Sun Mar 15 22:41:52.650 2009   (  9.43) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out

  36  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:04:45.586 2009  to  Mon Mar 16 04:08:08.083 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  37  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:08:08.083 2009  to  Mon Mar 16 04:08:35.666 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  38  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:08:35.666 2009  to  Mon Mar 16 04:12:51.080 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  39  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:12:51.080 2009  to  Mon Mar 16 04:17:36.565 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

  40  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:17:36.565 2009  to  Mon Mar 16 04:24:20.619 2009   (404.05) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

  41  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.620 2009  to  Mon Mar 16 04:24:20.620 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

  42  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.624 2009  to  Mon Mar 16 04:24:20.624 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

  43  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.625 2009  to  Mon Mar 16 04:24:20.625 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

  44  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.627 2009  to  Mon Mar 16 04:24:20.627 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

  45  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:28:51.786 2009  to  Mon Mar 16 04:28:51.981 2009   (  0.19) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

  46  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:42:17.498 2009  to  Mon Mar 16 04:42:17.937 2009   (  0.44) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:02.416 2009  to  Sun Mar 15 17:57:02.416 2009   (  0.00) secs
                     EL bad poly no. 72872: BAD Poly: EL = -4.691297e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:05.401 2009  to  Sun Mar 15 17:57:05.401 2009   (  0.00) secs
                     EL bad poly no. 72927: BAD Poly: EL = -4.689845e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:08.426 2009  to  Sun Mar 15 17:57:08.426 2009   (  0.00) secs
                     EL bad poly no. 72981: BAD Poly: EL = -4.688373e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:11.428 2009  to  Sun Mar 15 17:57:11.428 2009   (  0.00) secs
                     EL bad poly no. 73035: BAD Poly: EL = -4.686912e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:14.472 2009  to  Sun Mar 15 17:57:14.472 2009   (  0.00) secs
                     EL bad poly no. 73090: BAD Poly: EL = -4.685431e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:17.501 2009  to  Sun Mar 15 17:57:17.501 2009   (  0.00) secs
                     EL bad poly no. 73144: BAD Poly: EL = -4.683956e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:20.573 2009  to  Sun Mar 15 17:57:20.573 2009   (  0.00) secs
                     EL bad poly no. 73199: BAD Poly: EL = -4.682460e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:23.620 2009  to  Sun Mar 15 17:57:23.620 2009   (  0.00) secs
                     EL bad poly no. 73253: BAD Poly: EL = -4.680977e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:26.633 2009  to  Sun Mar 15 17:57:26.633 2009   (  0.00) secs
                     EL bad poly no. 73306: BAD Poly: EL = -4.679510e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:29.666 2009  to  Sun Mar 15 17:57:29.666 2009   (  0.00) secs
                     EL bad poly no. 73360: BAD Poly: EL = -4.678032e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:32.704 2009  to  Sun Mar 15 17:57:32.704 2009   (  0.00) secs
                     EL bad poly no. 73413: BAD Poly: EL = -4.676552e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:35.771 2009  to  Sun Mar 15 17:57:35.771 2009   (  0.00) secs
                     EL bad poly no. 73471: BAD Poly: EL = -4.675058e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:38.800 2009  to  Sun Mar 15 17:57:38.800 2009   (  0.00) secs
                     EL bad poly no. 73531: BAD Poly: EL = -4.673582e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:41.824 2009  to  Sun Mar 15 17:57:41.824 2009   (  0.00) secs
                     EL bad poly no. 73591: BAD Poly: EL = -4.672108e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:44.833 2009  to  Sun Mar 15 17:57:44.833 2009   (  0.00) secs
                     EL bad poly no. 73647: BAD Poly: EL = -4.670641e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:47.883 2009  to  Sun Mar 15 17:57:47.883 2009   (  0.00) secs
                     EL bad poly no. 73702: BAD Poly: EL = -4.669154e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:50.908 2009  to  Sun Mar 15 17:57:50.908 2009   (  0.00) secs
                     EL bad poly no. 73757: BAD Poly: EL = -4.667680e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:53.942 2009  to  Sun Mar 15 17:57:53.942 2009   (  0.00) secs
                     EL bad poly no. 73815: BAD Poly: EL = -4.666200e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:57:56.977 2009  to  Sun Mar 15 17:57:56.977 2009   (  0.00) secs
                     EL bad poly no. 73875: BAD Poly: EL = -4.664720e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:00.001 2009  to  Sun Mar 15 17:58:00.001 2009   (  0.00) secs
                     EL bad poly no. 73934: BAD Poly: EL = -4.663245e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:02.987 2009  to  Sun Mar 15 17:58:02.987 2009   (  0.00) secs
                     EL bad poly no. 73993: BAD Poly: EL = -4.661788e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:06.008 2009  to  Sun Mar 15 17:58:06.008 2009   (  0.00) secs
                     EL bad poly no. 74051: BAD Poly: EL = -4.660315e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:09.019 2009  to  Sun Mar 15 17:58:09.019 2009   (  0.00) secs
                     EL bad poly no. 74110: BAD Poly: EL = -4.658845e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:12.032 2009  to  Sun Mar 15 17:58:12.032 2009   (  0.00) secs
                     EL bad poly no. 74168: BAD Poly: EL = -4.657375e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Mar 15 17:58:15.046 2009  to  Sun Mar 15 17:58:15.046 2009   (  0.00) secs
                     EL bad poly no. 74226: BAD Poly: EL = -4.655905e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun Mar 15 18:07:18.198 2009  to  Sun Mar 15 18:07:18.198 2009   (  0.00) secs
                     LFBG bad poly no. 2: t0 is 2.500933e+00 seconds in the past!

  27  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:07:18.189 2009  to  Sun Mar 15 18:07:18.189 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:07:18.192 2009  to  Sun Mar 15 18:07:18.192 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:13:01.724 2009  to  Sun Mar 15 18:13:01.724 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:13:01.726 2009  to  Sun Mar 15 18:13:01.726 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.RTracker.badPoly                                        Sun Mar 15 18:13:01.733 2009  to  Sun Mar 15 18:13:01.733 2009   (  0.00) secs
                     LFBG bad poly no. 3: t0 is 2.053242e+00 seconds in the past!

  32  SHUTDOWN  PCS        shutdown                                                      Sun Mar 15 18:27:28.485 2009  to  Sun Mar 15 18:27:28.485 2009   (  0.00) secs
                     PCS subsystem shut down - PCS Version 3.33f

  33  FAILED    PCS        telescope.telemetryError                                      Sun Mar 15 18:27:28.566 2009  to  Sun Mar 15 18:27:28.566 2009   (  0.00) secs
                     PCS Telescope telemetry error: 2006: MySQL server has gone away

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Mar 15 18:27:29.313 2009  to  Sun Mar 15 18:27:29.313 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

  35  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Sun Mar 15 18:27:30.383 2009  to  Sun Mar 15 18:27:30.383 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

  36  STARTUP   PCS        startup                                                       Sun Mar 15 18:27:36.501 2009  to  Sun Mar 15 18:27:36.501 2009   (  0.00) secs
                     PCS subsystem started - PCS Version 3.33f

  37  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:28:39.423 2009  to  Sun Mar 15 18:29:03.790 2009   ( 24.37) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

  38  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.497 2009  to  Sun Mar 15 18:28:39.562 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  39  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:28:39.434 2009  to  Sun Mar 15 18:28:40.020 2009   (  0.59) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for right LBC at prime focus: PCS reports MCSPU error returned - ERROR: rotator is not READY
                     IIF TCS authorize command failed for right LBC at prime focus

  40  FAILED    PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.562 2009  to  Sun Mar 15 18:28:39.607 2009   (  0.04) secs
                    Started event but no Complete event
                     PCS will stop tracking target
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  41  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:28:39.670 2009  to  Sun Mar 15 18:28:39.670 2009   (  0.00) secs
                    Failed event but no Started event
                     PCS reports MCSPU error returned - ERROR: rotator is not READY

  42  FAILED    IIF GUI    IIFCommand.authorize                                          Sun Mar 15 18:29:16.541 2009  to  Sun Mar 15 18:29:17.773 2009   (  1.23) secs
                     IIF TCS authorize command started for right LBC at prime focus
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

  43  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:29:16.610 2009  to  Sun Mar 15 18:29:16.675 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  44  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:29:16.814 2009  to  Sun Mar 15 18:29:16.814 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  45  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Sun Mar 15 18:29:17.529 2009  to  Sun Mar 15 18:34:06.527 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

  46  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Sun Mar 15 18:29:17.607 2009  to  Sun Mar 15 18:29:17.607 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

  47  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Sun Mar 15 18:30:22.375 2009  to  Sun Mar 15 18:30:22.375 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.started

  48  STARTUP   OSS        side[0].tertiary_mirror.startup.command                       Sun Mar 15 18:30:24.846 2009  to  Sun Mar 15 18:30:24.846 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [startup] command.complete

  49  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sun Mar 15 18:32:02.161 2009  to  Sun Mar 15 18:32:05.508 2009   (  3.35) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:32:02.298 2009  to  Sun Mar 15 18:32:05.376 2009   (  3.08) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:32:02.214 2009  to  Sun Mar 15 18:32:05.450 2009   (  3.24) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:34:05.571 2009  to  Sun Mar 15 18:34:05.647 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

  53  SEQERROR  PCS        telescope.command.stopTracking                                Sun Mar 15 18:34:05.735 2009  to  Sun Mar 15 18:34:05.735 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

  54  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 15 18:43:47.875 2009  to  Sun Mar 15 18:43:48.597 2009   (  0.72) secs
                     IIF Preset command started for left LUCIFER mode TRACK from IIF
                     IIF Preset alert for left LUCIFER mode TRACK: PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 Az: 3.612356786104244e-01 El: -4.154021225526930e-01
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  55  FAILED    PCS        telescope.command.setEquatorialTarget                         Sun Mar 15 18:43:48.424 2009  to  Sun Mar 15 18:43:48.477 2009   (  0.05) secs
                     PCS will set new equatorial target to RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 RotMode: PARALLACTIC Angle: 0.000000000000000e+00 Wavelength: 0.0000000e+00 Side: 0
                     PCS setEquatorialTarget failed. Target below the horizon (-0.0174 radians) on side 0 with RA: 4.326496682768743e+00 Dec: 5.261585918345572e-01 Az: 3.612356786104244e-01 El: -4.154021225526930e-01

  56  FAILED    IIF        command.preset.(TRACK)                                        Sun Mar 15 18:44:59.070 2009  to  Sun Mar 15 18:46:48.145 2009   (109.08) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode TRACK: Primary mirror collimation reached limit
                     IIF Preset alert for left LUCIFER mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                     IIF Preset command failed for left LUCIFER mode TRACK from IIF

  57  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:45:39.642 2009  to  Sun Mar 15 18:46:47.958 2009   ( 68.32) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  58  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:45:39.708 2009  to  Sun Mar 15 18:46:47.890 2009   ( 68.18) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PSF        primaryMirror.command.revert                                  Sun Mar 15 18:46:50.070 2009  to  Sun Mar 15 18:47:07.547 2009   ( 17.48) secs
                     left PSF primary mirror revert to just collimation table failed because Primary mirror collimation reached limit

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:47:05.289 2009  to  Sun Mar 15 18:47:07.486 2009   (  2.20) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:47:05.352 2009  to  Sun Mar 15 18:47:07.409 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PSF        primaryMirror.command.setSecondaryOffload                     Sun Mar 15 18:47:08.669 2009  to  Sun Mar 15 18:47:11.010 2009   (  2.34) secs
                     left PSF primary mirror setSecondaryOffload failed because Primary mirror collimation failed

  63  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 18:47:08.721 2009  to  Sun Mar 15 18:47:10.955 2009   (  2.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 18:47:08.831 2009  to  Sun Mar 15 18:47:10.888 2009   (  2.06) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:33.865 2009  to  Sun Mar 15 18:54:33.865 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0849129e-04 3.3384562e-04 3.0190945e-03 2.2622108e-02 8.1604958e-02 2.1954775e-02

  66  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:34.122 2009  to  Sun Mar 15 18:54:34.122 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -3.0849129e-04 3.3384562e-04 3.0190945e-03 2.2622108e-02 8.1604958e-02 2.1954775e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.058 2009  to  Sun Mar 15 18:54:41.058 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  68  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.316 2009  to  Sun Mar 15 18:54:41.316 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  69  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:41.565 2009  to  Sun Mar 15 18:54:41.565 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  70  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:47.890 2009  to  Sun Mar 15 18:54:47.890 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  71  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:54:48.144 2009  to  Sun Mar 15 18:54:48.144 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:01.553 2009  to  Sun Mar 15 18:55:01.553 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.0797821e-04 4.6789646e-05 3.0202270e-03 3.8274765e-02 5.4702282e-02 4.2569876e-02

  73  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:01.809 2009  to  Sun Mar 15 18:55:01.809 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -8.0797821e-04 4.6789646e-05 3.0202270e-03 3.8274765e-02 5.4702282e-02 4.2569876e-02

  74  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:11.787 2009  to  Sun Mar 15 18:55:11.787 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  75  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:12.042 2009  to  Sun Mar 15 18:55:12.042 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  76  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.105 2009  to  Sun Mar 15 18:55:13.105 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  77  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.361 2009  to  Sun Mar 15 18:55:13.361 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  78  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.616 2009  to  Sun Mar 15 18:55:13.616 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  79  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:13.871 2009  to  Sun Mar 15 18:55:13.871 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.8432906e-04 3.4397840e-04 3.0303001e-03 -4.0721893e-04 4.2358398e-02 4.3141305e-02

  80  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:16.554 2009  to  Sun Mar 15 18:55:16.554 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  81  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:16.810 2009  to  Sun Mar 15 18:55:16.810 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  82  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:30.225 2009  to  Sun Mar 15 18:55:30.225 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  83  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:30.480 2009  to  Sun Mar 15 18:55:30.480 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  84  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:32.148 2009  to  Sun Mar 15 18:55:32.148 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  85  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:32.405 2009  to  Sun Mar 15 18:55:32.405 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  86  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.065 2009  to  Sun Mar 15 18:55:33.065 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  87  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.321 2009  to  Sun Mar 15 18:55:33.321 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  88  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:33.578 2009  to  Sun Mar 15 18:55:33.578 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  89  FAILED    PSF        primaryMirror.positionError                                   Sun Mar 15 18:55:35.095 2009  to  Sun Mar 15 18:55:35.095 2009   (  0.00) secs
                     left PSF primary mirror collimation position error: -2.9104203e-04 -2.5486946e-04 3.0233264e-03 3.1945229e-02 4.2994976e-02 2.1713495e-02

  90  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 18:57:05.302 2009  to  Sun Mar 15 18:58:07.099 2009   ( 61.80) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  91  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 18:57:50.790 2009  to  Sun Mar 15 18:58:06.883 2009   ( 16.09) secs
                     couldn''t find a star in any GS location.

  92  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 18:59:41.909 2009  to  Sun Mar 15 19:00:36.527 2009   ( 54.62) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

  93  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 19:00:21.853 2009  to  Sun Mar 15 19:00:36.164 2009   ( 14.31) secs
                     couldn''t find a star in any GS location.

  94  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Sun Mar 15 19:01:37.252 2009  to  Sun Mar 15 19:02:02.593 2009   ( 25.34) secs
                     left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  95  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Mar 15 19:01:37.368 2009  to  Sun Mar 15 19:02:02.469 2009   ( 25.10) secs
                     left PMC Mirror ChaseStop Command Started
                     left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  96  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Mar 15 19:01:37.305 2009  to  Sun Mar 15 19:02:02.537 2009   ( 25.23) secs
                     left PSF primary mirror chaseStop started
                     left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  97  FAILED    PMC        VxInterface.lengthError                                       Sun Mar 15 19:40:52.216 2009  to  Sun Mar 15 19:40:52.216 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

  98  FAILED    PMC        VxInterface.close                                             Sun Mar 15 19:40:52.268 2009  to  Sun Mar 15 19:40:52.268 2009   (  0.00) secs
                     left PMC Actuator closing network connection

  99  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:23:43.911 2009  to  Sun Mar 15 21:25:05.291 2009   ( 81.38) secs
                     timeout waiting to receive an image

 100  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:25:17.022 2009  to  Sun Mar 15 21:26:38.444 2009   ( 81.42) secs
                     timeout waiting to receive an image

 101  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:26:44.977 2009  to  Sun Mar 15 21:28:06.366 2009   ( 81.39) secs
                     timeout waiting to receive an image

 102  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 21:28:12.677 2009  to  Sun Mar 15 21:29:34.092 2009   ( 81.42) secs
                     timeout waiting to receive an image

 103  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 21:30:08.651 2009  to  Sun Mar 15 21:30:08.651 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 104  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 21:30:09.563 2009  to  Sun Mar 15 21:30:09.563 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 105  STARTUP   GCS        startup                                                       Sun Mar 15 21:30:32.009 2009  to  Sun Mar 15 21:30:32.009 2009   (  0.00) secs
                     left GCS subsystem started

 106  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 21:59:09.368 2009  to  Sun Mar 15 22:00:11.247 2009   ( 61.88) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 107  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 21:59:49.206 2009  to  Sun Mar 15 22:00:10.944 2009   ( 21.74) secs
                     guiding was not stable within 6 cycles

 108  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:00:30.449 2009  to  Sun Mar 15 22:01:25.860 2009   ( 55.41) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 109  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:01:00.921 2009  to  Sun Mar 15 22:01:25.524 2009   ( 24.60) secs
                     guiding was not stable within 6 cycles

 110  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:17:21.795 2009  to  Sun Mar 15 22:18:45.896 2009   ( 84.10) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 4233 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 111  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:18:09.343 2009  to  Sun Mar 15 22:18:45.575 2009   ( 36.23) secs
                     guiding was not stable within 6 cycles

 112  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:18:39.108 2009  to  Sun Mar 15 22:18:39.108 2009   (  0.00) secs
                     no guide star found

 113  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:18:43.998 2009  to  Sun Mar 15 22:18:43.998 2009   (  0.00) secs
                     no guide star found

 114  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:20:06.149 2009  to  Sun Mar 15 22:21:25.371 2009   ( 79.22) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 115  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:20:31.916 2009  to  Sun Mar 15 22:21:25.084 2009   ( 53.17) secs
                     guiding was not stable within 6 cycles

 116  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:04.007 2009  to  Sun Mar 15 22:21:04.007 2009   (  0.00) secs
                     no guide star found

 117  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:08.834 2009  to  Sun Mar 15 22:21:08.834 2009   (  0.00) secs
                     no guide star found

 118  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:13.709 2009  to  Sun Mar 15 22:21:13.709 2009   (  0.00) secs
                     no guide star found

 119  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:18.542 2009  to  Sun Mar 15 22:21:18.542 2009   (  0.00) secs
                     no guide star found

 120  FAILED    GCS        guidethread.warning                                           Sun Mar 15 22:21:23.401 2009  to  Sun Mar 15 22:21:23.401 2009   (  0.00) secs
                     no guide star found

 121  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:41:14.569 2009  to  Sun Mar 15 22:41:52.821 2009   ( 38.25) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 122  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Sun Mar 15 22:41:43.219 2009  to  Sun Mar 15 22:41:52.650 2009   (  9.43) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out

 123  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Sun Mar 15 22:41:43.365 2009  to  Sun Mar 15 22:43:35.643 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 124  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Sun Mar 15 22:41:52.588 2009  to  Sun Mar 15 22:41:52.588 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation.moveMirrorAbs.waitForInPositionAll] Wait for ''in position'' timed out

 125  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:50:53.600 2009  to  Sun Mar 15 22:52:07.612 2009   ( 74.01) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 126  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 22:51:41.030 2009  to  Sun Mar 15 22:52:07.352 2009   ( 26.32) secs
                     guiding was not stable within 6 cycles

 127  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 22:53:01.363 2009  to  Sun Mar 15 22:53:57.484 2009   ( 56.12) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 128  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Sun Mar 15 22:53:45.909 2009  to  Sun Mar 15 22:53:57.363 2009   ( 11.45) secs
                     couldn''t find a star in any GS location.

 129  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 22:59:07.727 2009  to  Sun Mar 15 23:00:29.465 2009   ( 81.74) secs
                     timeout waiting to receive an image

 130  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:00:38.336 2009  to  Sun Mar 15 23:02:00.016 2009   ( 81.68) secs
                     timeout waiting to receive an image

 131  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:02:08.791 2009  to  Sun Mar 15 23:03:31.196 2009   ( 82.41) secs
                     timeout waiting to receive an image

 132  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:03:42.933 2009  to  Sun Mar 15 23:05:05.169 2009   ( 82.24) secs
                     timeout waiting to receive an image

 133  FAILED    GCS        interface.azcam.wfsc.readout                                  Sun Mar 15 23:05:12.462 2009  to  Sun Mar 15 23:06:34.402 2009   ( 81.94) secs
                     timeout waiting to receive an image

 134  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 23:07:44.500 2009  to  Sun Mar 15 23:07:44.500 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 135  SHUTDOWN  GCS        command.shutdown                                              Sun Mar 15 23:07:45.726 2009  to  Sun Mar 15 23:07:45.726 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 136  STARTUP   GCS        startup                                                       Sun Mar 15 23:08:13.259 2009  to  Sun Mar 15 23:08:13.259 2009   (  0.00) secs
                     left GCS subsystem started

 137  FAILED    IIF        command.preset.(ACTIVE)                                       Sun Mar 15 23:12:39.075 2009  to  Sun Mar 15 23:14:25.091 2009   (106.02) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode ACTIVE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 247
                     IIF Preset alert for left LUCIFER mode ACTIVE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 138  FAILED    GCS        command.autoAcquireGuidestar                                  Sun Mar 15 23:13:40.789 2009  to  Sun Mar 15 23:14:24.641 2009   ( 43.85) secs
                     guiding was not stable within 6 cycles

 139  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:11.970 2009  to  Sun Mar 15 23:14:11.970 2009   (  0.00) secs
                     no guide star found

 140  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:17.261 2009  to  Sun Mar 15 23:14:17.261 2009   (  0.00) secs
                     no guide star found

 141  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:14:22.798 2009  to  Sun Mar 15 23:14:22.798 2009   (  0.00) secs
                     no guide star found

 142  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:15:48.560 2009  to  Sun Mar 15 23:15:48.560 2009   (  0.00) secs
                     no guide star found

 143  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:15:57.585 2009  to  Sun Mar 15 23:15:57.585 2009   (  0.00) secs
                     no guide star found

 144  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:32.307 2009  to  Sun Mar 15 23:16:32.307 2009   (  0.00) secs
                     no guide star found

 145  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:38.147 2009  to  Sun Mar 15 23:16:38.147 2009   (  0.00) secs
                     no guide star found

 146  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:43.812 2009  to  Sun Mar 15 23:16:43.812 2009   (  0.00) secs
                     no guide star found

 147  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:49.238 2009  to  Sun Mar 15 23:16:49.238 2009   (  0.00) secs
                     no guide star found

 148  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:16:54.747 2009  to  Sun Mar 15 23:16:54.747 2009   (  0.00) secs
                     no guide star found

 149  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:00.357 2009  to  Sun Mar 15 23:17:00.357 2009   (  0.00) secs
                     no guide star found

 150  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:05.665 2009  to  Sun Mar 15 23:17:05.665 2009   (  0.00) secs
                     no guide star found

 151  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:11.156 2009  to  Sun Mar 15 23:17:11.156 2009   (  0.00) secs
                     no guide star found

 152  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:16.534 2009  to  Sun Mar 15 23:17:16.534 2009   (  0.00) secs
                     no guide star found

 153  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:22.009 2009  to  Sun Mar 15 23:17:22.009 2009   (  0.00) secs
                     no guide star found

 154  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:27.420 2009  to  Sun Mar 15 23:17:27.420 2009   (  0.00) secs
                     no guide star found

 155  FAILED    GCS        guidethread.warning                                           Sun Mar 15 23:17:32.924 2009  to  Sun Mar 15 23:17:32.924 2009   (  0.00) secs
                     no guide star found

 156  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:23:04.071 2009  to  Mon Mar 16 00:24:42.028 2009   ( 97.96) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 157  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 00:24:10.223 2009  to  Mon Mar 16 00:24:41.740 2009   ( 31.52) secs
                     guiding was not stable within 6 cycles

 158  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 00:30:38.221 2009  to  Mon Mar 16 00:30:38.221 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 159  FAILED    PMC        VxInterface.close                                             Mon Mar 16 00:30:38.276 2009  to  Mon Mar 16 00:30:38.276 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 160  FAILED    GCS        command.stopWFsensing                                         Mon Mar 16 00:34:31.810 2009  to  Mon Mar 16 00:34:38.732 2009   (  6.92) secs
                     WFS loop didn''t stop within timeout.

 161  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:37:25.505 2009  to  Mon Mar 16 00:38:31.786 2009   ( 66.28) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 162  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 00:38:08.624 2009  to  Mon Mar 16 00:38:31.498 2009   ( 22.87) secs
                     guiding was not stable within 6 cycles

 163  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:38:57.655 2009  to  Mon Mar 16 00:39:43.475 2009   ( 45.82) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 164  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 00:39:31.226 2009  to  Mon Mar 16 00:39:43.230 2009   ( 12.00) secs
                     couldn''t find a star in any GS location.

 165  FAILED    MCS.MCSPU  MCSPU.TPlcDevice.readError                                    Mon Mar 16 00:39:32.093 2009  to  Mon Mar 16 00:39:32.093 2009   (  0.00) secs
                     A TPLC read produced an error (bad read size) 2 times

 166  FAILED    IIF        command.preset.(ACTIVE)                                       Mon Mar 16 00:44:01.431 2009  to  Mon Mar 16 00:44:19.109 2009   ( 17.68) secs
                     IIF Preset command started for left LUCIFER mode ACTIVE from IIF
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGw command status: AGW1: Requested position is Out of Range
                     IIF Preset alert for left LUCIFER mode ACTIVE: couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGw command status: AGW1: Requested position is Out of Rangeerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 175.595, 15.5391, 15.8079 mm.
                     IIF Preset alert for left LUCIFER mode ACTIVE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 167  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 00:44:02.869 2009  to  Mon Mar 16 00:44:18.828 2009   ( 15.96) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 168  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 00:44:17.968 2009  to  Mon Mar 16 00:44:18.773 2009   (  0.80) secs
                     couldn''t move probe to position (SFP) 175.595, 15.5391, focus: 15.8079 :AGW1: Requested position is Out of Range

 169  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 01:12:01.850 2009  to  Mon Mar 16 01:12:01.850 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 170  FAILED    PMC        VxInterface.close                                             Mon Mar 16 01:12:01.903 2009  to  Mon Mar 16 01:12:01.903 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 171  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 01:31:31.456 2009  to  Mon Mar 16 01:31:31.456 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 172  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 01:31:32.700 2009  to  Mon Mar 16 01:31:32.700 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 173  STARTUP   GCS        startup                                                       Mon Mar 16 01:31:43.994 2009  to  Mon Mar 16 01:31:43.994 2009   (  0.00) secs
                     left GCS subsystem started

 174  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:48:30.862 2009  to  Mon Mar 16 01:49:27.795 2009   ( 56.93) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 175  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:49:05.463 2009  to  Mon Mar 16 01:49:27.503 2009   ( 22.04) secs
                     guiding was not stable within 6 cycles

 176  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:51:05.383 2009  to  Mon Mar 16 01:51:41.687 2009   ( 36.30) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t find a star in any GS location.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 177  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 01:51:41.334 2009  to  Mon Mar 16 01:51:41.507 2009   (  0.17) secs
                    

 178  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Mon Mar 16 01:51:41.560 2009  to  Mon Mar 16 01:51:41.560 2009   (  0.00) secs
                     couldn''t find a star in any GS location.

 179  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:54:47.411 2009  to  Mon Mar 16 01:55:47.198 2009   ( 59.79) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 180  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 01:55:19.563 2009  to  Mon Mar 16 01:55:19.563 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 181  FAILED    PMC        VxInterface.close                                             Mon Mar 16 01:55:19.615 2009  to  Mon Mar 16 01:55:19.615 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 182  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:55:25.061 2009  to  Mon Mar 16 01:55:46.914 2009   ( 21.85) secs
                     guiding was not stable within 6 cycles

 183  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 01:58:00.431 2009  to  Mon Mar 16 01:59:29.307 2009   ( 88.88) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t adjust exposure time to meet low counts requirement. star too dim or guide rate too high.
                     IIF Preset alert for left LUCIFER mode GUIDE: maximum exposure time is 4600 ms at the given guide rate, estimated counts are 35
                     IIF Preset alert for left LUCIFER mode GUIDE: adjusted exposure time to 4600 ms
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 184  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 01:58:35.542 2009  to  Mon Mar 16 01:59:28.859 2009   ( 53.32) secs
                     guiding was not stable within 6 cycles

 185  FAILED    GCS        guidethread.warning                                           Mon Mar 16 01:59:14.743 2009  to  Mon Mar 16 01:59:14.743 2009   (  0.00) secs
                     no guide star found

 186  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:08:49.858 2009  to  Mon Mar 16 02:09:52.794 2009   ( 62.94) secs
                     IIF Preset command wait for telescope started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: guiding was not stable within 6 cycles
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 187  FAILED    GCS        command.autoAcquireGuidestar                                  Mon Mar 16 02:09:26.514 2009  to  Mon Mar 16 02:09:52.510 2009   ( 26.00) secs
                     guiding was not stable within 6 cycles

 188  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 02:11:42.616 2009  to  Mon Mar 16 02:11:42.616 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 189  FAILED    PMC        VxInterface.close                                             Mon Mar 16 02:11:42.667 2009  to  Mon Mar 16 02:11:42.667 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 190  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 02:23:00.583 2009  to  Mon Mar 16 02:23:00.583 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 191  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 02:23:01.714 2009  to  Mon Mar 16 02:23:01.714 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 192  STARTUP   GCS        startup                                                       Mon Mar 16 02:23:09.512 2009  to  Mon Mar 16 02:23:09.512 2009   (  0.00) secs
                     left GCS subsystem started

 193  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:23:43.005 2009  to  Mon Mar 16 02:24:14.011 2009   ( 31.01) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: IIF Preset command aborted for left LUCIFER mode GUIDE from IIF
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 194  SEQERROR  IIF        command.preset.elevationWait                                  Mon Mar 16 02:24:01.829 2009  to  Mon Mar 16 02:25:16.254 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command wait for elevation started for left LUCIFER

 195  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 02:24:29.581 2009  to  Mon Mar 16 02:24:31.102 2009   (  1.52) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 196  SEQERROR  PCS        telescope.command.startTracking                               Mon Mar 16 02:24:30.255 2009  to  Mon Mar 16 02:24:58.453 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will start tracking target

 197  FAILED    PMC        VxInterface.close                                             Mon Mar 16 03:12:54.820 2009  to  Mon Mar 16 03:12:54.820 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 198  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 03:12:54.768 2009  to  Mon Mar 16 03:12:54.768 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 199  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:51:11.016 2009  to  Mon Mar 16 03:51:23.223 2009   ( 12.21) secs
                     could not set exposure time with AzCam server

 200  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 03:51:23.384 2009  to  Mon Mar 16 03:52:14.786 2009   ( 51.40) secs
                     AzCam server timed out waiting for full CCD readout

 201  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:52:14.871 2009  to  Mon Mar 16 03:52:17.949 2009   (  3.08) secs
                     could not set exposure time with AzCam server

 202  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 03:52:26.202 2009  to  Mon Mar 16 03:52:32.135 2009   (  5.93) secs
                     could not set exposure time with AzCam server

 203  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 03:52:32.310 2009  to  Mon Mar 16 03:53:23.817 2009   ( 51.51) secs
                     AzCam server timed out waiting for full CCD readout

 204  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 03:53:27.761 2009  to  Mon Mar 16 03:53:27.761 2009   (  0.00) secs
                     left GCS ShutDown Command Started

 205  SHUTDOWN  GCS        command.shutdown                                              Mon Mar 16 03:53:29.640 2009  to  Mon Mar 16 03:53:29.640 2009   (  0.00) secs
                     left GCS ShutDown Command Complete

 206  STARTUP   GCS        startup                                                       Mon Mar 16 03:53:57.192 2009  to  Mon Mar 16 03:53:57.192 2009   (  0.00) secs
                     left GCS subsystem started

 207  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 04:00:17.443 2009  to  Mon Mar 16 04:00:17.443 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 208  FAILED    PMC        VxInterface.close                                             Mon Mar 16 04:00:17.496 2009  to  Mon Mar 16 04:00:17.496 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 209  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:04:15.565 2009  to  Mon Mar 16 04:07:50.195 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

 210  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:04:45.645 2009  to  Mon Mar 16 04:08:08.568 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 211  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:04:45.586 2009  to  Mon Mar 16 04:08:08.083 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

 212  STARTUP   GCS        startup                                                       Mon Mar 16 04:06:56.272 2009  to  Mon Mar 16 04:06:56.272 2009   (  0.00) secs
                     left GCS subsystem started

 213  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:07:50.195 2009  to  Mon Mar 16 04:08:05.814 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

 214  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:08:05.814 2009  to  Mon Mar 16 04:11:57.719 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

 215  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:08:08.083 2009  to  Mon Mar 16 04:08:35.666 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

 216  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:08:08.568 2009  to  Mon Mar 16 04:08:35.780 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 217  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:08:35.666 2009  to  Mon Mar 16 04:12:51.080 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

 218  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:08:35.780 2009  to  Mon Mar 16 04:12:51.140 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 219  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:11:57.719 2009  to  Mon Mar 16 04:17:15.516 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF

 220  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:12:51.080 2009  to  Mon Mar 16 04:17:36.565 2009   (  0.00) secs
                    Started event but no Complete event
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future

 221  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:12:51.140 2009  to  Mon Mar 16 04:17:36.680 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 222  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:17:15.516 2009  to  Mon Mar 16 04:24:20.759 2009   (425.24) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset alert for left LUCIFER mode GUIDE: Invalid buffer: RPCERROR
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 223  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:17:36.565 2009  to  Mon Mar 16 04:24:20.619 2009   (404.05) secs
                     left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

 224  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:17:36.680 2009  to  Mon Mar 16 04:28:51.861 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 225  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 04:17:38.288 2009  to  Mon Mar 16 04:17:38.288 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 226  FAILED    PMC        VxInterface.close                                             Mon Mar 16 04:17:38.338 2009  to  Mon Mar 16 04:17:38.338 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 227  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.620 2009  to  Mon Mar 16 04:24:20.620 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

 228  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.624 2009  to  Mon Mar 16 04:24:20.624 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

 229  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.625 2009  to  Mon Mar 16 04:24:20.625 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

 230  SEQERROR  PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:24:20.627 2009  to  Mon Mar 16 04:24:20.627 2009   (  0.00) secs
                    Failed event but no Started event
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because Invalid buffer: RPCERROR

 231  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.802 2009  to  Mon Mar 16 04:24:20.802 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 232  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.814 2009  to  Mon Mar 16 04:24:20.814 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 233  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.878 2009  to  Mon Mar 16 04:24:20.878 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 234  SEQERROR  IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:24:20.888 2009  to  Mon Mar 16 04:24:20.888 2009   (  0.00) secs
                    Failed event but no Started event
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 235  STARTUP   OSS        startup                                                       Mon Mar 16 04:24:32.783 2009  to  Mon Mar 16 04:24:32.783 2009   (  0.00) secs
                     The oss was started.

 236  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:28:32.077 2009  to  Mon Mar 16 04:28:54.896 2009   ( 22.82) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 237  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:28:51.786 2009  to  Mon Mar 16 04:28:51.981 2009   (  0.19) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

 238  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:28:51.861 2009  to  Mon Mar 16 04:42:17.564 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 239  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Mon Mar 16 04:28:51.914 2009  to  Mon Mar 16 04:28:51.914 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

 240  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:29:57.978 2009  to  Mon Mar 16 04:30:03.233 2009   (  0.00) secs
                    Started event but no Complete event
                     IIF TCS authorize command started for left LUCIFER at bentGregorianFront focus

 241  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:29:58.048 2009  to  Mon Mar 16 04:29:58.111 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 242  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:29:58.254 2009  to  Mon Mar 16 04:29:58.254 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 243  SEQERROR  OSS        side[0].tertiary_mirror.movefocalstation.command              Mon Mar 16 04:29:59.004 2009  to  Mon Mar 16 04:30:04.775 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [moveFocalStation] command.started

 244  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:29:59.222 2009  to  Mon Mar 16 04:29:59.222 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 245  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:29:59.249 2009  to  Mon Mar 16 04:29:59.249 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 246  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Mar 16 04:30:00.251 2009  to  Mon Mar 16 04:30:00.251 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 247  FAILED    IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:30:03.233 2009  to  Mon Mar 16 04:30:05.634 2009   (  2.40) secs
                     IIF TCS authorize alert for left LUCIFER at bentGregorianFront focus: oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.
                     IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

 248  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:30:03.303 2009  to  Mon Mar 16 04:30:03.368 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 249  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:30:03.508 2009  to  Mon Mar 16 04:30:03.508 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 250  FAILED    OSS        side[0].tertiary_mirror.movefocalstation.failed               Mon Mar 16 04:30:05.280 2009  to  Mon Mar 16 04:30:05.280 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [moveFocalStation.moveSelAbs] Umac brake not set.

 251  SEQERROR  IIF GUI    IIFCommand.authorize                                          Mon Mar 16 04:30:22.315 2009  to  Mon Mar 16 04:30:22.315 2009   (  0.00) secs
                    Complete event but no Started event
                     IIF TCS authorize command complete for left LUCIFER at bentGregorianFront focus

 252  SHUTDOWN  OSS        shutdown                                                      Mon Mar 16 04:35:57.322 2009  to  Mon Mar 16 04:35:57.322 2009   (  0.00) secs
                     The oss was shut down.

 253  STARTUP   OSS        startup                                                       Mon Mar 16 04:36:17.645 2009  to  Mon Mar 16 04:36:17.645 2009   (  0.00) secs
                     The oss was started.

 254  FAILED    MCS.MCSPU  MCSPU.Brake.brakeCmdTimeOut                                   Mon Mar 16 04:39:34.498 2009  to  Mon Mar 16 04:39:34.498 2009   (  0.00) secs
                     EL brake command timed out. Didnt get msg back from PLC within time limit.

 255  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:40:35.174 2009  to  Mon Mar 16 04:40:35.174 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 256  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:40:35.180 2009  to  Mon Mar 16 04:40:35.180 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 257  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 16 04:40:35.282 2009  to  Mon Mar 16 04:40:35.282 2009   (  0.00) secs
                     drive cabinet has turned on.

 258  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 259  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 260  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.291 2009  to  Mon Mar 16 04:40:36.291 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 261  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.292 2009  to  Mon Mar 16 04:40:36.292 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 262  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 263  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 264  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.293 2009  to  Mon Mar 16 04:40:36.293 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 265  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 04:40:36.294 2009  to  Mon Mar 16 04:40:36.294 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 266  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 04:41:58.004 2009  to  Mon Mar 16 04:42:25.827 2009   ( 27.82) secs
                     IIF Preset command wait for elevation started for left LUCIFER
                     IIF Preset alert for left LUCIFER mode GUIDE: oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 267  SEQERROR  OSS        side[0].tertiary_mirror.adjustcurrfocalstation.command        Mon Mar 16 04:42:17.564 2009  to  Mon Mar 16 04:44:12.849 2009   (  0.00) secs
                    Started event but no Complete event
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] command.started

 268  FAILED    PSF        tertiaryMirror.command.adjustMirrorCollimation                Mon Mar 16 04:42:17.498 2009  to  Mon Mar 16 04:42:17.937 2009   (  0.44) secs
                     left PSF tertiary mirror adjustMirrorCollimation started with rzColl 0 for 0 seconds in the future
                     left PSF tertiary mirror adjustMirrorCollimation with rzColl 0 for 0 seconds in the future failed because oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

 269  FAILED    OSS        side[0].tertiary_mirror.adjustcurrfocalstation.failed         Mon Mar 16 04:42:17.671 2009  to  Mon Mar 16 04:42:17.671 2009   (  0.00) secs
                     oss.side[0].tertiary_mirror: [adjustCurrFocalStation] Not at a focal station

 270  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:42:54.372 2009  to  Mon Mar 16 04:42:54.439 2009   (  0.00) secs
                    Started event but no Complete event
                     PCS will stop tracking target

 271  SEQERROR  PCS        telescope.command.stopTracking                                Mon Mar 16 04:42:54.577 2009  to  Mon Mar 16 04:42:54.577 2009   (  0.00) secs
                    Complete event but no Started event
                     PCS stopped tracking

 272  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:42:55.494 2009  to  Mon Mar 16 04:42:55.494 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 273  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 04:42:55.521 2009  to  Mon Mar 16 04:42:55.521 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 274  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Mon Mar 16 04:42:56.506 2009  to  Mon Mar 16 04:42:56.506 2009   (  0.00) secs
                     There have been no LFBG track polys for 2.000000000000000e+00 .

 275  FAILED    PMC        VxInterface.close                                             Mon Mar 16 05:13:29.341 2009  to  Mon Mar 16 05:13:29.341 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 276  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 05:13:29.289 2009  to  Mon Mar 16 05:13:29.289 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 277  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 05:17:50.396 2009  to  Mon Mar 16 05:18:10.330 2009   ( 19.93) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGw command status: AGW1: Axes had not been homed, yet
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.436301, 132.256, 22.4097 mm.
                     IIF Preset alert for left LUCIFER mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 278  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 05:17:51.814 2009  to  Mon Mar 16 05:18:10.060 2009   ( 18.25) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 279  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 05:18:00.140 2009  to  Mon Mar 16 05:18:10.008 2009   (  9.87) secs
                     couldn''t move probe to position (SFP) 0.436301, 132.256, focus: 22.4097 :AGW1: Axes had not been homed, yet

 280  FAILED    IIF        command.preset.(GUIDE)                                        Mon Mar 16 05:20:06.300 2009  to  Mon Mar 16 05:20:27.971 2009   ( 21.67) secs
                     IIF Preset command started for left LUCIFER mode GUIDE from IIF
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGw command status: AGW1: Axes had not been homed, yet
                     IIF Preset alert for left LUCIFER mode GUIDE: couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): -0.321467, -0.0491577, 30.9874 mm.
                     IIF Preset alert for left LUCIFER mode GUIDE: guidestar list successfully changed but probe couldn''t be moved to position.
                     IIF Preset command failed for left LUCIFER mode GUIDE from IIF

 281  FAILED    GCS        command.setGuidestarList                                      Mon Mar 16 05:20:07.367 2009  to  Mon Mar 16 05:20:27.696 2009   ( 20.33) secs
                     guidestar list successfully changed but probe couldn''t be moved to position

 282  FAILED    GCS        interface.agw.setProbePosition                                Mon Mar 16 05:20:14.990 2009  to  Mon Mar 16 05:20:27.641 2009   ( 12.65) secs
                     couldn''t move probe to position (SFP) -0.321467, -0.0491577, focus: 30.9874 :AGW1: Axes had not been homed, yet

 283  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 05:25:30.895 2009  to  Mon Mar 16 05:26:22.532 2009   ( 51.64) secs
                     AzCam server timed out waiting for full CCD readout

 284  STARTUP   GCS        startup                                                       Mon Mar 16 05:26:50.777 2009  to  Mon Mar 16 05:26:50.777 2009   (  0.00) secs
                     left GCS subsystem started

 285  FAILED    PMC        VxInterface.selectTimeout                                     Mon Mar 16 05:28:41.954 2009  to  Mon Mar 16 05:28:41.954 2009   (  0.00) secs
                     left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 286  FAILED    PMC        thermal.badReceive                                            Mon Mar 16 05:28:42.058 2009  to  Mon Mar 16 05:28:42.058 2009   (  0.00) secs
                     left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 287  FAILED    PMC        VxInterface.packetReadError                                   Mon Mar 16 05:28:42.006 2009  to  Mon Mar 16 05:28:42.006 2009   (  0.00) secs
                     left PMC Thermal packet read error: 5002

 288  FAILED    PMC        VxInterface.close                                             Mon Mar 16 05:53:11.285 2009  to  Mon Mar 16 05:53:11.285 2009   (  0.00) secs
                     left PMC Actuator closing network connection

 289  FAILED    PMC        VxInterface.lengthError                                       Mon Mar 16 05:53:11.233 2009  to  Mon Mar 16 05:53:11.233 2009   (  0.00) secs
                     left PMC Actuator length error: expected 152, got 96

 290  FAILED    GCS        command.setWFCamExposureTime                                  Mon Mar 16 05:57:28.871 2009  to  Mon Mar 16 05:57:31.730 2009   (  2.86) secs
                     could not set exposure time with AzCam server

 291  FAILED    GCS        command.getFullWFImage                                        Mon Mar 16 05:57:31.887 2009  to  Mon Mar 16 05:58:23.357 2009   ( 51.47) secs
                     AzCam server timed out waiting for full CCD readout

 292  STARTUP   GCS        startup                                                       Mon Mar 16 05:58:40.650 2009  to  Mon Mar 16 05:58:40.650 2009   (  0.00) secs
                     left GCS subsystem started

 293  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:17.747 2009  to  Mon Mar 16 06:03:17.747 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 294  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:22.879 2009  to  Mon Mar 16 06:03:22.879 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 295  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:26.174 2009  to  Mon Mar 16 06:03:26.174 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 296  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:28.985 2009  to  Mon Mar 16 06:03:28.985 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 297  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:03:31.795 2009  to  Mon Mar 16 06:03:31.795 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 298  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Mon Mar 16 06:03:34.011 2009  to  Mon Mar 16 06:03:34.011 2009   (  0.00) secs
                     TPLC has failed to acknowledge a command to turn on the power amplifiers.

 299  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckTimeOut                                Mon Mar 16 06:04:12.321 2009  to  Mon Mar 16 06:04:12.321 2009   (  0.00) secs
                     TPLC failed to ACK a command to turn on the power amplifiers after 1000

 300  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 16 06:04:28.199 2009  to  Mon Mar 16 06:04:28.199 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 301  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Mon Mar 16 06:04:31.808 2009  to  Mon Mar 16 06:04:31.808 2009   (  0.00) secs
                     Main program is terminating.

 302  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 06:05:14.501 2009  to  Mon Mar 16 06:05:14.501 2009   (  0.00) secs
                     There have been no AZ track polys for 1.000000000000000e+00 .

 303  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Mon Mar 16 06:05:14.504 2009  to  Mon Mar 16 06:05:14.504 2009   (  0.00) secs
                     There have been no EL track polys for 1.000000000000000e+00 .

 304  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Mon Mar 16 06:05:14.608 2009  to  Mon Mar 16 06:05:14.608 2009   (  0.00) secs
                     drive cabinet has turned on.

 305  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.627 2009  to  Mon Mar 16 06:05:15.627 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 306  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.627 2009  to  Mon Mar 16 06:05:15.627 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 307  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.628 2009  to  Mon Mar 16 06:05:15.628 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 308  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.628 2009  to  Mon Mar 16 06:05:15.628 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 309  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.629 2009  to  Mon Mar 16 06:05:15.629 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 310  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 311  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 312  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Mar 16 06:05:15.630 2009  to  Mon Mar 16 06:05:15.630 2009   (  0.00) secs
                     swingarms locked out because telescope is not stowed at zenith.

 313  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Mon Mar 16 06:07:44.751 2009  to  Mon Mar 16 06:07:44.751 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 314  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Mon Mar 16 06:07:44.752 2009  to  Mon Mar 16 06:07:44.752 2009   (  0.00) secs
                     A brake command failed to complete successfully.

 315  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Mon Mar 16 06:08:26.833 2009  to  Mon Mar 16 06:08:26.833 2009   (  0.00) secs
                     MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can''t follow tel. Going to "hold" mode.

 316  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Mon Mar 16 06:08:30.535 2009  to  Mon Mar 16 06:08:30.535 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 317  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Mon Mar 16 06:08:30.644 2009  to  Mon Mar 16 06:08:30.644 2009   (  0.00) secs
                     Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

**********************************************************