You are here: Foswiki>Software Web>TCSSWReportFile_090226 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Feb 26 2009 to Feb 27 2009
 
    Reporting period beginning:   Thu Feb 26 17:44:01.601 2009
    Reporting period ending:      Fri Feb 27 07:19:53.748 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.eventQueueFull,  priority = 0, 2
      event = MCS.MCSPU.MEncoders.earlyStrobe,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.06   100.0 %        183        183                      
                                                                       0.01    0.02    0.01    0.06
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.32    0.40    0.12    1.90   100.0 %        456        456                      
                                                                       0.32    0.40    0.12    1.90
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.09    0.09    0.05    1.05   100.0 %        244        244                      
                                                                       0.09    0.09    0.05    1.05
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.54    6.12    0.35   65.53    99.1 %        456        452          4           
                                                                       5.93    6.01    2.19   63.42
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .   28.25    8.75    3.33  285.28   100.0 %         98         98                      
                                                                      28.25    8.75    3.33  285.28
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .   28.27    7.98    2.01  284.60   100.0 %         98         98                      
                                                                      28.27    7.98    2.01  284.60
     command.preset.elevationWait . . . . . . . . . . . . . . . . .    0.45    1.43    1.01    2.04   100.0 %         13         13                      
                                                                       0.45    1.43    1.01    2.04
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.02    2.04    2.03    2.10   100.0 %         13         13                      
                                                                       0.02    2.04    2.03    2.10
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .    1.68   10.51    8.17   12.89   100.0 %         13         13                      
                                                                       1.68   10.51    8.17   12.89
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    8.89    6.73    0.32  122.48    99.1 %        543        538          5           
                                                                       5.97    6.30    0.32   43.91
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.42    5.23    4.22    6.23   100.0 %          2          2                      
                                                                       1.42    5.23    4.22    6.23

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            18

IIF Events of Interest

   1  FAILED    IIF        command.sendWavefront                                         Thu Feb 26 19:12:15.441 2009  to  Thu Feb 26 19:12:45.942 2009   ( 30.50) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

   2  FAILED    IIF        command.sendWavefront                                         Thu Feb 26 23:09:03.066 2009  to  Thu Feb 26 23:09:09.597 2009   (  6.53) secs
                    IIF Guide command started for right LBC, coord1 8.677418826079772e-07, coord2 1.682495302043813e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

   3  FAILED    IIF        command.moveFocus                                             Thu Feb 26 23:20:39.118 2009  to  Thu Feb 26 23:20:39.469 2009   (  0.35) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

   4  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:18:34.108 2009  to  Fri Feb 27 00:20:18.826 2009   (104.72) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

   5  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:22:19.618 2009  to  Fri Feb 27 00:24:22.095 2009   (122.48) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

   6  FAILED    IIF        command.moveFocus                                             Fri Feb 27 00:24:55.354 2009  to  Fri Feb 27 00:26:00.889 2009   ( 65.53) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488930898148148e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   7  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:27:22.629 2009  to  Fri Feb 27 00:27:23.209 2009   (  0.58) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF SendWavefront command failed for right LBC for M1

   8  FAILED    IIF        command.moveFocus                                             Fri Feb 27 00:27:24.515 2009  to  Fri Feb 27 00:27:24.952 2009   (  0.44) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   9  FAILED    IIF        command.moveFocus                                             Fri Feb 27 06:01:30.263 2009  to  Fri Feb 27 06:01:38.538 2009   (  8.28) secs
                    IIF MoveFocus command started for right LBC for 2.390000000000000e-01
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 2.390000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     7                      
                                                                                                   
     chiller.controlValve.command.close . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.controlValve.command.open. . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.controlValve.command.resetAlarm. . . . . . . . . . . .                                   100.0 %                                2           
                                                                                                   
     chiller.controlValve.command.setState. . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     chiller.pump.command.setState. . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4210                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8420                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                    13                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                    13                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     168                      

ECS Events of Interest

   1  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Feb 26 23:45:44.490 2009  to  Thu Feb 26 23:45:44.490 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

   2  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Feb 26 23:55:33.744 2009  to  Thu Feb 26 23:55:33.744 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       7
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       4

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         46                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.getFullGuideImage. . . . . . . . . . . . . . . . . . .    2.92    2.68    0.06    5.84    98.2 %        628                    11           
                                                                                                   
     command.getFullWFImage . . . . . . . . . . . . . . . . . . . .    2.41    1.42    0.09    6.02    98.2 %        879                    16           
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         34                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          6                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         46                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         23                                 
                                                                                                   
     command.setAGW . . . . . . . . . . . . . . . . . . . . . . . .    3.37    1.72    0.01   11.68    97.9 %         48         47                      
                                                                       3.37    1.72    0.01   11.68
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %         29                                 
                                                                                                   
     command.setWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %         42                                 
                                                                                                   
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         22                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest

   1  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:16:33.015 2009  to  Thu Feb 26 20:16:38.853 2009   (  5.84) secs
                    AzCam server timed out waiting for full CCD readout

   2  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:17:04.267 2009  to  Thu Feb 26 20:17:04.595 2009   (  0.33) secs
                    request to AzCam server for a full CCD readout failed

   3  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:42:35.414 2009  to  Thu Feb 26 20:42:41.171 2009   (  5.76) secs
                    AzCam server timed out waiting for full CCD readout

   4  STARTUP   GCS        startup                                                       Thu Feb 26 21:05:29.100 2009  to  Thu Feb 26 21:05:29.100 2009   (  0.00) secs
                    left GCS subsystem started

   5  STARTUP   GCS        startup                                                       Thu Feb 26 21:07:18.662 2009  to  Thu Feb 26 21:07:18.662 2009   (  0.00) secs
                    left GCS subsystem started

   6  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:20:09.322 2009  to  Thu Feb 26 21:20:15.007 2009   (  5.68) secs
                    AzCam server timed out waiting for full CCD readout

   7  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:21:17.491 2009  to  Thu Feb 26 21:21:20.847 2009   (  3.36) secs
                    AzCam server timed out waiting for full CCD readout

   8  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:09.484 2009  to  Thu Feb 26 21:23:09.615 2009   (  0.13) secs
                    request to AzCam server for a full CCD readout failed

   9  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:17.748 2009  to  Thu Feb 26 21:23:17.902 2009   (  0.15) secs
                    request to AzCam server for a full CCD readout failed

  10  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:26.981 2009  to  Thu Feb 26 21:23:27.088 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  11  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:39.654 2009  to  Thu Feb 26 21:23:39.759 2009   (  0.10) secs
                    request to AzCam server for a full CCD readout failed

  12  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:58.374 2009  to  Thu Feb 26 21:23:58.491 2009   (  0.12) secs
                    request to AzCam server for a full CCD readout failed

  13  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:25:10.540 2009  to  Thu Feb 26 21:25:10.633 2009   (  0.09) secs
                    request to AzCam server for a full CCD readout failed

  14  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:27:35.737 2009  to  Thu Feb 26 21:27:35.842 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  15  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:27:55.897 2009  to  Thu Feb 26 21:27:56.015 2009   (  0.12) secs
                    request to AzCam server for a full CCD readout failed

  16  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:28:34.636 2009  to  Thu Feb 26 21:28:34.742 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  17  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 21:36:56.608 2009  to  Thu Feb 26 21:36:56.608 2009   (  0.00) secs
                    left GCS ShutDown Command Started

  18  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 21:36:57.963 2009  to  Thu Feb 26 21:36:57.963 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

  19  STARTUP   GCS        startup                                                       Thu Feb 26 21:39:52.477 2009  to  Thu Feb 26 21:39:52.477 2009   (  0.00) secs
                    left GCS subsystem started

  20  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:41:04.392 2009  to  Thu Feb 26 21:41:10.416 2009   (  6.02) secs
                    AzCam server timed out waiting for full CCD readout

  21  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:41:24.820 2009  to  Thu Feb 26 21:41:24.926 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  22  STARTUP   GCS        startup                                                       Thu Feb 26 21:41:49.575 2009  to  Thu Feb 26 21:41:49.575 2009   (  0.00) secs
                    left GCS subsystem started

  23  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:49:21.646 2009  to  Thu Feb 26 21:49:27.354 2009   (  5.71) secs
                    AzCam server timed out waiting for full CCD readout

  24  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:49:40.694 2009  to  Thu Feb 26 21:49:40.828 2009   (  0.13) secs
                    request to AzCam server for a full CCD readout failed

  25  STARTUP   GCS        startup                                                       Thu Feb 26 21:50:55.181 2009  to  Thu Feb 26 21:50:55.181 2009   (  0.00) secs
                    left GCS subsystem started

  26  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:57:44.988 2009  to  Thu Feb 26 21:57:50.901 2009   (  5.91) secs
                    AzCam server timed out waiting for full CCD readout

  27  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:59:01.879 2009  to  Thu Feb 26 21:59:07.898 2009   (  6.02) secs
                    AzCam server timed out waiting for full CCD readout

  28  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:59:23.069 2009  to  Thu Feb 26 21:59:23.176 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  29  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 22:04:28.152 2009  to  Thu Feb 26 22:04:28.257 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  30  STARTUP   GCS        startup                                                       Thu Feb 26 22:06:12.754 2009  to  Thu Feb 26 22:06:12.754 2009   (  0.00) secs
                    left GCS subsystem started

  31  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:09:49.367 2009  to  Thu Feb 26 22:09:55.058 2009   (  5.69) secs
                    AzCam server timed out waiting for full CCD readout

  32  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:10:32.163 2009  to  Thu Feb 26 22:10:32.224 2009   (  0.06) secs
                    request to AzCam server for a full CCD readout failed

  33  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:10:37.389 2009  to  Thu Feb 26 22:10:37.489 2009   (  0.10) secs
                    request to AzCam server for a full CCD readout failed

  34  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:11:21.705 2009  to  Thu Feb 26 22:11:21.810 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

  35  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:16:02.032 2009  to  Thu Feb 26 22:16:02.125 2009   (  0.09) secs
                    request to AzCam server for a full CCD readout failed

  36  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 22:16:13.384 2009  to  Thu Feb 26 22:16:13.384 2009   (  0.00) secs
                    left GCS ShutDown Command Started

  37  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 22:16:14.560 2009  to  Thu Feb 26 22:16:14.560 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

  38  STARTUP   GCS        startup                                                       Thu Feb 26 22:16:50.012 2009  to  Thu Feb 26 22:16:50.012 2009   (  0.00) secs
                    left GCS subsystem started
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       7                      
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                845           
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .     185                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .     114                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                            10
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           252
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      45                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      45                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      55                      
     MCSPU.Tracker.toPosMode. . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .     108                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      51                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .     102                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      62                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     716                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     762                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     254                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 16           
     MCSPU.ELDrive.regen_ok_not . . . . . . . . . . . . . . . . . .                          6127
     MCSPU.eventQueueFull . . . . . . . . . . . . . . . . . . . . .       3                     1
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      75                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            97
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            42
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     442                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .      17                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .      18                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      54                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                 17           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .     129                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .     265                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .     265                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      55                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.ElBrakes.elbrk . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Brake.unsuccessfulCompletion . . . . . . . . . . . . . .                 14           
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      67                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            11
     MCSPU.Main.termination . . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      20                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  5           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      60                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 40           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      10                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       3                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Diagn.elenergize . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Diagn.elampsenable . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.BrakeFailSet2. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       8                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Servo.disarm . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.MEncoders.earlyStrobe. . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.foundPressureOn . . . . . . . . . . .      21                      
     MCSPU.AZDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:01.601 2009  to  Thu Feb 26 17:44:01.601 2009   (  0.00) secs
                    EL bad poly no. 67297: BAD Poly: EL = -3.623907e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:04.659 2009  to  Thu Feb 26 17:44:04.659 2009   (  0.00) secs
                    EL bad poly no. 67342: BAD Poly: EL = -3.622278e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:07.720 2009  to  Thu Feb 26 17:44:07.720 2009   (  0.00) secs
                    EL bad poly no. 67384: BAD Poly: EL = -3.620648e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:10.798 2009  to  Thu Feb 26 17:44:10.798 2009   (  0.00) secs
                    EL bad poly no. 67429: BAD Poly: EL = -3.619007e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:13.809 2009  to  Thu Feb 26 17:44:13.809 2009   (  0.00) secs
                    EL bad poly no. 67471: BAD Poly: EL = -3.617402e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:16.860 2009  to  Thu Feb 26 17:44:16.860 2009   (  0.00) secs
                    EL bad poly no. 67516: BAD Poly: EL = -3.615777e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:19.865 2009  to  Thu Feb 26 17:44:19.865 2009   (  0.00) secs
                    EL bad poly no. 67558: BAD Poly: EL = -3.614175e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:22.900 2009  to  Thu Feb 26 17:44:22.900 2009   (  0.00) secs
                    EL bad poly no. 67602: BAD Poly: EL = -3.612558e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:25.967 2009  to  Thu Feb 26 17:44:25.967 2009   (  0.00) secs
                    EL bad poly no. 67645: BAD Poly: EL = -3.610923e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:28.981 2009  to  Thu Feb 26 17:44:28.981 2009   (  0.00) secs
                    EL bad poly no. 67689: BAD Poly: EL = -3.609316e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:32.022 2009  to  Thu Feb 26 17:44:32.022 2009   (  0.00) secs
                    EL bad poly no. 67731: BAD Poly: EL = -3.607695e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:35.022 2009  to  Thu Feb 26 17:44:35.022 2009   (  0.00) secs
                    EL bad poly no. 67774: BAD Poly: EL = -3.606095e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:38.066 2009  to  Thu Feb 26 17:44:38.066 2009   (  0.00) secs
                    EL bad poly no. 67817: BAD Poly: EL = -3.604472e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:41.097 2009  to  Thu Feb 26 17:44:41.097 2009   (  0.00) secs
                    EL bad poly no. 67861: BAD Poly: EL = -3.602856e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:44.124 2009  to  Thu Feb 26 17:44:44.124 2009   (  0.00) secs
                    EL bad poly no. 67903: BAD Poly: EL = -3.601242e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:47.171 2009  to  Thu Feb 26 17:44:47.171 2009   (  0.00) secs
                    EL bad poly no. 67947: BAD Poly: EL = -3.599616e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:50.211 2009  to  Thu Feb 26 17:44:50.211 2009   (  0.00) secs
                    EL bad poly no. 67989: BAD Poly: EL = -3.597995e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:53.272 2009  to  Thu Feb 26 17:44:53.272 2009   (  0.00) secs
                    EL bad poly no. 68034: BAD Poly: EL = -3.596361e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:56.288 2009  to  Thu Feb 26 17:44:56.288 2009   (  0.00) secs
                    EL bad poly no. 68075: BAD Poly: EL = -3.594753e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:59.282 2009  to  Thu Feb 26 17:44:59.282 2009   (  0.00) secs
                    EL bad poly no. 68117: BAD Poly: EL = -3.593155e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:02.308 2009  to  Thu Feb 26 17:45:02.308 2009   (  0.00) secs
                    EL bad poly no. 68158: BAD Poly: EL = -3.591541e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:05.332 2009  to  Thu Feb 26 17:45:05.332 2009   (  0.00) secs
                    EL bad poly no. 68201: BAD Poly: EL = -3.589926e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:08.412 2009  to  Thu Feb 26 17:45:08.412 2009   (  0.00) secs
                    EL bad poly no. 68242: BAD Poly: EL = -3.588283e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:11.437 2009  to  Thu Feb 26 17:45:11.437 2009   (  0.00) secs
                    EL bad poly no. 68285: BAD Poly: EL = -3.586668e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:14.434 2009  to  Thu Feb 26 17:45:14.434 2009   (  0.00) secs
                    EL bad poly no. 68325: BAD Poly: EL = -3.585069e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 26 23:30:03.265 2009  to  Thu Feb 26 23:30:03.265 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 26 23:30:03.333 2009  to  Thu Feb 26 23:30:03.333 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 00:12:32.140 2009  to  Fri Feb 27 00:12:32.140 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 00:12:32.182 2009  to  Fri Feb 27 00:12:32.182 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:30:23.196 2009  to  Fri Feb 27 00:30:23.196 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  31  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:30:27.685 2009  to  Fri Feb 27 00:30:27.685 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  32  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:31:14.528 2009  to  Fri Feb 27 00:31:14.528 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  33  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 00:34:16.217 2009  to  Fri Feb 27 00:34:16.217 2009   (  0.00) secs
                    

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:45:13.971 2009  to  Fri Feb 27 00:45:13.971 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  35  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 00:48:32.372 2009  to  Fri Feb 27 00:48:32.372 2009   (  0.00) secs
                    

  36  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 01:08:50.828 2009  to  Fri Feb 27 01:08:50.828 2009   (  0.00) secs
                    

  37  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:28:56.645 2009  to  Fri Feb 27 01:28:56.645 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  38  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:29:44.530 2009  to  Fri Feb 27 01:29:44.530 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:29:53.235 2009  to  Fri Feb 27 01:29:53.235 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:31:15.200 2009  to  Fri Feb 27 01:31:15.200 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  41  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:32:34.633 2009  to  Fri Feb 27 01:32:34.633 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  42  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:33:15.927 2009  to  Fri Feb 27 01:33:15.927 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  43  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:34:51.352 2009  to  Fri Feb 27 01:34:51.352 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  44  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:35:17.188 2009  to  Fri Feb 27 01:35:17.188 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  45  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:35:30.104 2009  to  Fri Feb 27 01:35:30.104 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  46  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.346 2009  to  Fri Feb 27 01:38:33.346 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  47  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.347 2009  to  Fri Feb 27 01:38:33.347 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  48  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.348 2009  to  Fri Feb 27 01:38:33.348 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  49  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.507 2009  to  Fri Feb 27 01:38:49.507 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  50  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.508 2009  to  Fri Feb 27 01:38:49.508 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  51  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.563 2009  to  Fri Feb 27 01:38:49.563 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  52  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.610 2009  to  Fri Feb 27 01:39:07.610 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  53  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.665 2009  to  Fri Feb 27 01:39:07.665 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  54  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.667 2009  to  Fri Feb 27 01:39:07.667 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  55  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:52:20.651 2009  to  Fri Feb 27 01:52:20.651 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  56  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Fri Feb 27 01:56:05.780 2009  to  Fri Feb 27 01:56:05.780 2009   (  0.00) secs
                    Main program is terminating.

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 01:56:51.680 2009  to  Fri Feb 27 01:56:51.680 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 01:56:51.689 2009  to  Fri Feb 27 01:56:51.689 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  59  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 01:56:51.785 2009  to  Fri Feb 27 01:56:51.785 2009   (  0.00) secs
                    drive cabinet has turned on.

  60  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.294 2009  to  Fri Feb 27 01:56:52.294 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  61  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.294 2009  to  Fri Feb 27 01:56:52.294 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  62  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.295 2009  to  Fri Feb 27 01:56:52.295 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  63  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.295 2009  to  Fri Feb 27 01:56:52.295 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  64  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.296 2009  to  Fri Feb 27 01:56:52.296 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  65  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.296 2009  to  Fri Feb 27 01:56:52.296 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  66  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.297 2009  to  Fri Feb 27 01:56:52.297 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  67  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.298 2009  to  Fri Feb 27 01:56:52.298 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  68  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.676 2009  to  Fri Feb 27 01:58:28.676 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  69  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.677 2009  to  Fri Feb 27 01:58:28.677 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  70  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.786 2009  to  Fri Feb 27 01:58:28.786 2009   (  0.00) secs
                    A brake command failed to complete successfully.

  71  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:59:18.172 2009  to  Fri Feb 27 01:59:18.172 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  72  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:09:56.338 2009  to  Fri Feb 27 02:09:56.338 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:09:56.345 2009  to  Fri Feb 27 02:09:56.345 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  74  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:09:56.443 2009  to  Fri Feb 27 02:09:56.443 2009   (  0.00) secs
                    drive cabinet has turned on.

  75  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.962 2009  to  Fri Feb 27 02:09:56.962 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  76  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.962 2009  to  Fri Feb 27 02:09:56.962 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  77  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.963 2009  to  Fri Feb 27 02:09:56.963 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  78  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.963 2009  to  Fri Feb 27 02:09:56.963 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  79  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.964 2009  to  Fri Feb 27 02:09:56.964 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  80  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  81  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  82  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  83  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 02:10:32.614 2009  to  Fri Feb 27 02:10:32.614 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  84  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 02:21:27.436 2009  to  Fri Feb 27 02:21:27.436 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  85  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Fri Feb 27 02:22:41.100 2009  to  Fri Feb 27 02:22:41.100 2009   (  0.00) secs
                    Tried to set brakes a second time and they failed to set again.

  86  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Feb 27 02:22:41.099 2009  to  Fri Feb 27 02:22:41.099 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

  87  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:24:28.072 2009  to  Fri Feb 27 02:24:28.072 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  88  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:24:28.079 2009  to  Fri Feb 27 02:24:28.079 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  89  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:24:28.176 2009  to  Fri Feb 27 02:24:28.176 2009   (  0.00) secs
                    drive cabinet has turned on.

  90  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  91  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  92  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  93  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.692 2009  to  Fri Feb 27 02:24:28.692 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  94  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.693 2009  to  Fri Feb 27 02:24:28.693 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  95  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.693 2009  to  Fri Feb 27 02:24:28.693 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  96  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.694 2009  to  Fri Feb 27 02:24:28.694 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  97  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.694 2009  to  Fri Feb 27 02:24:28.694 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  98  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:30:29.846 2009  to  Fri Feb 27 02:30:29.846 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  99  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:30:29.850 2009  to  Fri Feb 27 02:30:29.850 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 100  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:30:29.944 2009  to  Fri Feb 27 02:30:29.944 2009   (  0.00) secs
                    drive cabinet has turned on.

 101  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:30:30.461 2009  to  Fri Feb 27 02:30:30.461 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:37:12.359 2009  to  Fri Feb 27 02:37:12.359 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 103  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:37:12.367 2009  to  Fri Feb 27 02:37:12.367 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 104  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:37:12.465 2009  to  Fri Feb 27 02:37:12.465 2009   (  0.00) secs
                    drive cabinet has turned on.

 105  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Feb 27 06:47:37.363 2009  to  Fri Feb 27 06:47:37.363 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

 106  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Feb 27 06:47:40.902 2009  to  Fri Feb 27 06:47:40.902 2009   (  0.00) secs
                    Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 107  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Feb 27 06:47:41.011 2009  to  Fri Feb 27 06:47:41.011 2009   (  0.00) secs
                    Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 108  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Feb 27 06:48:46.989 2009  to  Fri Feb 27 06:48:46.989 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 109  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 06:48:47.318 2009  to  Fri Feb 27 06:48:47.318 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 110  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 06:48:47.372 2009  to  Fri Feb 27 06:48:47.372 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 111  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Fri Feb 27 06:48:48.995 2009  to  Fri Feb 27 06:48:48.995 2009   (  0.00) secs
                    Cannot set all brakes or release all brakes.

 112  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 07:10:02.928 2009  to  Fri Feb 27 07:10:02.928 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 113  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 07:10:02.933 2009  to  Fri Feb 27 07:10:02.933 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.02    0.02    0.01    0.30   100.0 %        244        244                      
                                                                       0.02    0.02    0.01    0.30
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.10    0.06    0.25   100.0 %        456        456                      
                                                                       0.02    0.10    0.06    0.25
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.22    0.21    0.01    0.89   100.0 %         98         98                      
                                                                       0.22    0.21    0.01    0.89
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.32    0.21    0.02    1.25   100.0 %         31         31                      
                                                                       0.32    0.21    0.02    1.25
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.31    0.40    0.00    0.78     0.0 %         31                    31           
                                                                       0.12    0.61    0.52    0.78
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:00:28.950 2009  to  Thu Feb 26 19:43:15.453 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   2  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:00:29.220 2009  to  Thu Feb 26 19:00:29.220 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   3  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:43:15.453 2009  to  Thu Feb 26 19:53:02.804 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:43:15.720 2009  to  Thu Feb 26 19:43:15.720 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:06:09.597 2009  to  Thu Feb 26 20:17:12.068 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   6  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:06:09.866 2009  to  Thu Feb 26 20:06:09.866 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   7  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:39:29.666 2009  to  Thu Feb 26 20:51:16.349 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:39:29.933 2009  to  Thu Feb 26 20:39:29.933 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:20:06.091 2009  to  Thu Feb 26 21:32:02.409 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:20:06.359 2009  to  Thu Feb 26 21:20:06.359 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:58:42.332 2009  to  Thu Feb 26 22:26:48.092 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:58:42.600 2009  to  Thu Feb 26 21:58:42.600 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 23:33:15.449 2009  to  Thu Feb 26 23:43:11.879 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 23:33:15.713 2009  to  Thu Feb 26 23:33:15.713 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 01:06:04.389 2009  to  Fri Feb 27 03:26:39.032 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 01:06:04.659 2009  to  Fri Feb 27 01:06:04.659 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  17  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 05:11:19.449 2009  to  Fri Feb 27 05:20:03.342 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  18  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 05:11:19.716 2009  to  Fri Feb 27 05:11:19.716 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  19  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:08:56.384 2009  to  Fri Feb 27 06:09:28.147 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  20  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:08:56.652 2009  to  Fri Feb 27 06:08:56.652 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  21  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:09:28.414 2009  to  Fri Feb 27 06:09:28.414 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.02    1.02    1.02   100.0 %          3          3                      
                                                                       0.00    1.02    1.02    1.02
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.56    3.32    2.02    7.04   100.0 %        176        176                      
                                                                       1.56    3.32    2.02    7.04
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    6.01    5.45    2.02   22.06   100.0 %         12         12                      
                                                                       6.01    5.45    2.02   22.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    2.50    3.77    0.02    5.03    75.0 %          4          3          1           
                                                                       0.01    5.02    5.02    5.03
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.01   66.13   66.12   66.14   100.0 %          3          3                      
                                                                       0.01   66.13   66.12   66.14
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    8.15    6.16    0.00  117.25    98.9 %        980        969         11           
                                                                       6.33    5.91    2.02   67.15
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    0.00   11.04   11.04   11.04   100.0 %          1          1                      
                                                                       0.00   11.04   11.04   11.04
     mirror.command.pause . . . . . . . . . . . . . . . . . . . . .    0.00    0.02    0.02    0.02   100.0 %          1          1                      
                                                                       0.00    0.02    0.02    0.02
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .  109.55  162.40   48.16  266.56    33.3 %          3          1          2           
                                                                       0.00  172.49  172.49  172.49
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.04    0.05    0.03    0.09   100.0 %          3          3                      
                                                                       0.04    0.05    0.03    0.09
     mirror.command.unPause . . . . . . . . . . . . . . . . . . . .    0.00    0.02    0.02    0.02     0.0 %          1                     1           
                                                                                                   
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.01    0.04    0.02    0.05   100.0 %          7          7                      
                                                                       0.01    0.04    0.02    0.05

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             5
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 31           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 31           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      31                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            43
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     135                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           394
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       9                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  4           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       8                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           215
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           214
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  3           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       3                      
 *** actuator.neighborCheck.tripped . . . . . . . . . . . . . . . .                 36           
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             3
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                            18
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      15                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      15                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      15                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.autoRaiseRaiseTimeOut . . . . . . . . . . . . . . . . .                  1           
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                  4           
     actuator.getForce.readError. . . . . . . . . . . . . . . . . .                  2           
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                             4
     actuator.setForce.addressError . . . . . . . . . . . . . . . .                  4           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                 91           
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             7
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:40:57.527 2009  to  Thu Feb 26 18:40:57.527 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:40:57.552 2009  to  Thu Feb 26 18:40:57.552 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:41:04.540 2009  to  Thu Feb 26 18:41:04.540 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:41:04.516 2009  to  Thu Feb 26 18:41:04.516 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:44:15.821 2009  to  Thu Feb 26 18:44:15.821 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   6  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:44:15.798 2009  to  Thu Feb 26 18:44:15.798 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   7  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:04:19.431 2009  to  Thu Feb 26 19:04:19.431 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:04:19.413 2009  to  Thu Feb 26 19:04:19.413 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:07:30.208 2009  to  Thu Feb 26 19:07:30.208 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:07:30.175 2009  to  Thu Feb 26 19:07:30.175 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 19:12:18.682 2009  to  Thu Feb 26 19:12:45.753 2009   ( 27.07) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:12:44.263 2009  to  Thu Feb 26 19:12:44.263 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:12:44.235 2009  to  Thu Feb 26 19:12:44.235 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:18:16.393 2009  to  Thu Feb 26 19:18:16.393 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:18:16.377 2009  to  Thu Feb 26 19:18:16.377 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:02:06.299 2009  to  Thu Feb 26 20:02:06.299 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:02:06.278 2009  to  Thu Feb 26 20:02:06.278 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:18:33.447 2009  to  Thu Feb 26 20:18:33.447 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  19  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:18:33.432 2009  to  Thu Feb 26 20:18:33.432 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  20  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:27:35.447 2009  to  Thu Feb 26 20:27:35.447 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:27:35.472 2009  to  Thu Feb 26 20:27:35.472 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:56:00.109 2009  to  Thu Feb 26 20:56:00.109 2009   (  0.00) secs
                    left PMC Motor closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:56:00.088 2009  to  Thu Feb 26 20:56:00.088 2009   (  0.00) secs
                    left PMC Motor length error: expected 40, got 96

  24  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:09:07.987 2009  to  Thu Feb 26 21:09:07.987 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  25  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:09:07.968 2009  to  Thu Feb 26 21:09:07.968 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:10:38.172 2009  to  Thu Feb 26 21:10:38.172 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:10:38.155 2009  to  Thu Feb 26 21:10:38.155 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  28  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:33:45.445 2009  to  Thu Feb 26 21:33:45.445 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:33:45.462 2009  to  Thu Feb 26 21:33:45.462 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:38:49.217 2009  to  Thu Feb 26 21:38:49.217 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:38:49.198 2009  to  Thu Feb 26 21:38:49.198 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:58:54.831 2009  to  Thu Feb 26 21:58:54.831 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:58:54.816 2009  to  Thu Feb 26 21:58:54.816 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  34  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:03:26.392 2009  to  Thu Feb 26 22:03:26.392 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:03:26.375 2009  to  Thu Feb 26 22:03:26.375 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:22:47.318 2009  to  Thu Feb 26 22:22:47.318 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:22:47.300 2009  to  Thu Feb 26 22:22:47.300 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:38:22.469 2009  to  Thu Feb 26 22:38:22.469 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:38:22.452 2009  to  Thu Feb 26 22:38:22.452 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:48:49.085 2009  to  Thu Feb 26 22:48:49.085 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:48:49.064 2009  to  Thu Feb 26 22:48:49.064 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:05:24.019 2009  to  Thu Feb 26 23:05:24.019 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:05:24.006 2009  to  Thu Feb 26 23:05:24.006 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:09:03.444 2009  to  Thu Feb 26 23:09:09.469 2009   (  6.02) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  45  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:09:28.193 2009  to  Thu Feb 26 23:09:28.193 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:09:28.176 2009  to  Thu Feb 26 23:09:28.176 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  47  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:37.612 2009  to  Thu Feb 26 23:20:39.302 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:39.302 2009  to  Thu Feb 26 23:20:39.324 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:53.655 2009  to  Thu Feb 26 23:20:53.655 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  50  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:15.981 2009  to  Thu Feb 26 23:22:18.790 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:18.790 2009  to  Thu Feb 26 23:22:18.806 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  52  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:22.048 2009  to  Thu Feb 26 23:22:22.048 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  53  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:22:52.146 2009  to  Thu Feb 26 23:22:52.146 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:22:52.168 2009  to  Thu Feb 26 23:22:52.168 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.packetReadError                                   Thu Feb 26 23:24:15.509 2009  to  Thu Feb 26 23:24:15.509 2009   (  0.00) secs
                    left PMC PMCLogger packet read error: 5002

  56  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:15.492 2009  to  Thu Feb 26 23:24:15.492 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  57  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:15.835 2009  to  Thu Feb 26 23:24:15.835 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  58  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:16.154 2009  to  Thu Feb 26 23:24:16.154 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  59  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:16.480 2009  to  Thu Feb 26 23:24:16.480 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  60  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:32.745 2009  to  Thu Feb 26 23:24:32.934 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:32.934 2009  to  Thu Feb 26 23:24:32.948 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:38.785 2009  to  Thu Feb 26 23:24:38.785 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  63  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:43:14.678 2009  to  Thu Feb 26 23:43:14.678 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:43:14.661 2009  to  Thu Feb 26 23:43:14.661 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:18:34.469 2009  to  Fri Feb 27 00:20:18.682 2009   (104.21) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:22:24.690 2009  to  Fri Feb 27 00:24:21.937 2009   (117.25) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:24:55.540 2009  to  Fri Feb 27 00:26:00.694 2009   ( 65.15) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:26:29.493 2009  to  Fri Feb 27 00:26:29.493 2009   (  0.00) secs
                    right PMC ** PANIC: Hardpoint breakaway

  69  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:33.823 2009  to  Fri Feb 27 00:26:33.823 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 22)

  70  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:33.881 2009  to  Fri Feb 27 00:26:33.881 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 23)

  71  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.149 2009  to  Fri Feb 27 00:26:34.149 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 24)

  72  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.198 2009  to  Fri Feb 27 00:26:34.198 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 25)

  73  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.475 2009  to  Fri Feb 27 00:26:34.475 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 26)

  74  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.780 2009  to  Fri Feb 27 00:26:34.780 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 27)

  75  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.794 2009  to  Fri Feb 27 00:26:34.794 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 28)

  76  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.067 2009  to  Fri Feb 27 00:26:35.067 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 29)

  77  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.119 2009  to  Fri Feb 27 00:26:35.119 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 30)

  78  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.393 2009  to  Fri Feb 27 00:26:35.393 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 31)

  79  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.410 2009  to  Fri Feb 27 00:26:35.410 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 32)

  80  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.682 2009  to  Fri Feb 27 00:26:35.682 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 33)

  81  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.696 2009  to  Fri Feb 27 00:26:35.696 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 34)

  82  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.971 2009  to  Fri Feb 27 00:26:35.971 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 35)

  83  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.240 2009  to  Fri Feb 27 00:26:36.240 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 36)

  84  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.325 2009  to  Fri Feb 27 00:26:36.325 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 37)

  85  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.604 2009  to  Fri Feb 27 00:26:36.604 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 38)

  86  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.621 2009  to  Fri Feb 27 00:26:36.621 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 39)

  87  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.889 2009  to  Fri Feb 27 00:26:36.889 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 40)

  88  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.915 2009  to  Fri Feb 27 00:26:36.915 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 41)

  89  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.184 2009  to  Fri Feb 27 00:26:37.184 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 42)

  90  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.258 2009  to  Fri Feb 27 00:26:37.258 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 43)

  91  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.526 2009  to  Fri Feb 27 00:26:37.526 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 44)

  92  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.539 2009  to  Fri Feb 27 00:26:37.539 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 45)

  93  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.812 2009  to  Fri Feb 27 00:26:37.812 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 46)

  94  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:27:23.040 2009  to  Fri Feb 27 00:27:23.055 2009   (  0.01) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  95  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:27:24.750 2009  to  Fri Feb 27 00:27:24.795 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  96  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 27 00:28:51.641 2009  to  Fri Feb 27 00:29:39.797 2009   ( 48.16) secs
                    right PMC Actuator 101 get force read error: -3
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

  97  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Fri Feb 27 00:29:39.210 2009  to  Fri Feb 27 00:29:39.210 2009   (  0.00) secs
                    right PMC Auto-raise time-out: raise failed to finish in alloted time

  98  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:29:39.296 2009  to  Fri Feb 27 00:29:39.296 2009   (  0.00) secs
                    right PMC Actuator 434 set force read error: -3

  99  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:29:39.243 2009  to  Fri Feb 27 00:29:39.243 2009   (  0.00) secs
                    right PMC ** PANIC: User Button

 100  FAILED    PMC        actuator.getForce.readError                                   Fri Feb 27 00:29:39.322 2009  to  Fri Feb 27 00:29:39.322 2009   (  0.00) secs
                    right PMC Actuator 101 get force read error: -3
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 101  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:29:41.390 2009  to  Fri Feb 27 00:29:41.390 2009   (  0.00) secs
                    right PMC Actuator 337 set force bad return: 173 instead of 16

 102  FAILED    PMC        actuator.getForce.readError                                   Fri Feb 27 00:29:41.695 2009  to  Fri Feb 27 00:29:41.695 2009   (  0.00) secs
                    right PMC Actuator 211 get force read error: -3

 103  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.709 2009  to  Fri Feb 27 00:29:41.709 2009   (  0.00) secs
                    right PMC Actuator 421 has been reset

 104  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:29:41.681 2009  to  Fri Feb 27 00:29:41.681 2009   (  0.00) secs
                    right PMC Actuator 338 set force read error: -3

 105  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.738 2009  to  Fri Feb 27 00:29:41.738 2009   (  0.00) secs
                    right PMC Actuator 419 has been reset

 106  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.752 2009  to  Fri Feb 27 00:29:41.752 2009   (  0.00) secs
                    right PMC Actuator 417 has been reset

 107  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.778 2009  to  Fri Feb 27 00:29:41.778 2009   (  0.00) secs
                    right PMC Actuator 441 has been reset

 108  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.805 2009  to  Fri Feb 27 00:29:41.805 2009   (  0.00) secs
                    right PMC Actuator 415 has been reset

 109  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.821 2009  to  Fri Feb 27 00:29:41.821 2009   (  0.00) secs
                    right PMC Actuator 429 has been reset

 110  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.846 2009  to  Fri Feb 27 00:29:41.846 2009   (  0.00) secs
                    right PMC Actuator 422 has been reset

 111  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.862 2009  to  Fri Feb 27 00:29:41.862 2009   (  0.00) secs
                    right PMC Actuator 425 has been reset

 112  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.879 2009  to  Fri Feb 27 00:29:41.879 2009   (  0.00) secs
                    right PMC Actuator 426 has been reset

 113  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.893 2009  to  Fri Feb 27 00:29:41.893 2009   (  0.00) secs
                    right PMC Actuator 439 has been reset

 114  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.911 2009  to  Fri Feb 27 00:29:41.911 2009   (  0.00) secs
                    right PMC Actuator 427 has been reset

 115  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.948 2009  to  Fri Feb 27 00:29:41.948 2009   (  0.00) secs
                    right PMC Actuator 428 has been reset

 116  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.979 2009  to  Fri Feb 27 00:29:41.979 2009   (  0.00) secs
                    right PMC Actuator 431 has been reset

 117  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.995 2009  to  Fri Feb 27 00:29:41.995 2009   (  0.00) secs
                    right PMC Actuator 440 has been reset

 118  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.015 2009  to  Fri Feb 27 00:29:42.015 2009   (  0.00) secs
                    right PMC Actuator 436 has been reset

 119  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.048 2009  to  Fri Feb 27 00:29:42.048 2009   (  0.00) secs
                    right PMC Actuator 437 has been reset

 120  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.079 2009  to  Fri Feb 27 00:29:42.079 2009   (  0.00) secs
                    right PMC Actuator 443 has been reset

 121  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.095 2009  to  Fri Feb 27 00:29:42.095 2009   (  0.00) secs
                    right PMC Actuator 442 has been reset

 122  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.388 2009  to  Fri Feb 27 00:29:42.388 2009   (  0.00) secs
                    right PMC Actuator 411 has been reset

 123  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.416 2009  to  Fri Feb 27 00:29:42.416 2009   (  0.00) secs
                    right PMC Actuator 424 has been reset

 124  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:29:42.369 2009  to  Fri Feb 27 00:29:42.369 2009   (  0.00) secs
                    right PMC Actuator 410 set force bad return: 171 instead of 16

 125  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.437 2009  to  Fri Feb 27 00:29:42.437 2009   (  0.00) secs
                    right PMC Actuator 420 has been reset

 126  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.463 2009  to  Fri Feb 27 00:29:42.463 2009   (  0.00) secs
                    right PMC Actuator 434 has been reset

 127  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.481 2009  to  Fri Feb 27 00:29:42.481 2009   (  0.00) secs
                    right PMC Actuator 430 has been reset

 128  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.497 2009  to  Fri Feb 27 00:29:42.497 2009   (  0.00) secs
                    right PMC Actuator 438 has been reset

 129  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.514 2009  to  Fri Feb 27 00:29:42.514 2009   (  0.00) secs
                    right PMC Actuator 339 has been reset

 130  FAILED    PMC        mirror.command.unPause                                        Fri Feb 27 00:32:37.065 2009  to  Fri Feb 27 00:32:37.090 2009   (  0.02) secs
                    right PMC Mirror UnPause Command Started
                    right PMC Mirror UnPause Command Failed because Wrong mirror state

 131  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 27 00:34:00.010 2009  to  Fri Feb 27 00:38:26.574 2009   (266.56) secs
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 132  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:38:26.409 2009  to  Fri Feb 27 00:38:26.409 2009   (  0.00) secs
                    right PMC ** PANIC: Hardpoint breakaway

 133  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:38:28.491 2009  to  Fri Feb 27 00:38:28.491 2009   (  0.00) secs
                    right PMC Actuator 112 set force bad return: 179 instead of 2

 134  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:38:28.761 2009  to  Fri Feb 27 00:38:28.761 2009   (  0.00) secs
                    right PMC Actuator 118 set force read error: -3

 135  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:38:29.051 2009  to  Fri Feb 27 00:38:29.051 2009   (  0.00) secs
                    right PMC Actuator 117 set force bad return: 244 instead of 3

 136  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:38:29.033 2009  to  Fri Feb 27 00:38:29.033 2009   (  0.00) secs
                    right PMC Actuator 122 set force read error: -3

 137  FAILED    PMC        command.recoverPanic                                          Fri Feb 27 00:38:35.690 2009  to  Fri Feb 27 00:38:35.706 2009   (  0.02) secs
                    right PMC RecoverPanic Command Started
                    right PMC RecoverPanic Command Failed because Wrong mirror state

 138  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 27 03:37:53.248 2009  to  Fri Feb 27 03:37:53.248 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 139  FAILED    PMC        VxInterface.close                                             Fri Feb 27 03:37:53.274 2009  to  Fri Feb 27 03:37:53.274 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 140  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 06:01:30.342 2009  to  Fri Feb 27 06:01:38.373 2009   (  8.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    8.89    6.61    0.22  122.34    99.1 %        543        538          5           
                                                                       5.97    6.19    0.22   43.79
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.05   100.0 %         26         26                      
                                                                       0.01    0.02    0.01    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    6.52    6.04    0.22   65.37    99.1 %        458        454          4           
                                                                       5.91    5.93    2.14   63.36
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    8.89    6.66    0.26  122.38    99.1 %        543        538          5           
                                                                       5.97    6.23    0.26   43.85
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    8.85    6.60    0.00  122.26    98.8 %        571        564          7           
                                                                       6.10    6.24    0.15   43.71
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    8.15    6.24    0.00  117.30    98.9 %        980        969         11           
                                                                       6.33    5.99    2.07   67.21
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    6.01    5.53    2.08   22.13   100.0 %         12         12                      
                                                                       6.01    5.53    2.08   22.13
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.06    0.03    0.28   100.0 %        261        261                      
                                                                       0.03    0.06    0.03    0.28
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   19.33   57.88   36.31   87.42   100.0 %          6          6                      
                                                                      19.33   57.88   36.31   87.42
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    5.08    6.94    2.15   15.17   100.0 %          5          5                      
                                                                       5.08    6.94    2.15   15.17
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    6.52    5.99    0.16   65.33    99.1 %        458        454          4           
                                                                       5.91    5.88    2.10   63.30
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.03    0.02    0.06   100.0 %         22         22                      
                                                                       0.01    0.03    0.02    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.02    0.01    0.08   100.0 %        565        565                      
                                                                       0.01    0.02    0.01    0.08

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               2043           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:41.814 2009  to  Thu Feb 26 18:26:41.814 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

   2  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.068 2009  to  Thu Feb 26 18:26:42.068 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

   3  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.286 2009  to  Thu Feb 26 18:26:42.286 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

   4  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.510 2009  to  Thu Feb 26 18:26:42.510 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

   5  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.730 2009  to  Thu Feb 26 18:26:42.730 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

   6  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.948 2009  to  Thu Feb 26 18:26:42.948 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

   7  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.172 2009  to  Thu Feb 26 18:26:43.172 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

   8  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.392 2009  to  Thu Feb 26 18:26:43.392 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

   9  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.614 2009  to  Thu Feb 26 18:26:43.614 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  10  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.833 2009  to  Thu Feb 26 18:26:43.833 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  11  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.069 2009  to  Thu Feb 26 18:26:44.069 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  12  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.294 2009  to  Thu Feb 26 18:26:44.294 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

  13  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.523 2009  to  Thu Feb 26 18:26:44.523 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  14  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.743 2009  to  Thu Feb 26 18:26:44.743 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  15  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.968 2009  to  Thu Feb 26 18:26:44.968 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  16  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.192 2009  to  Thu Feb 26 18:26:45.192 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  17  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.414 2009  to  Thu Feb 26 18:26:45.414 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  18  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.634 2009  to  Thu Feb 26 18:26:45.634 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  19  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.869 2009  to  Thu Feb 26 18:26:45.869 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  20  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.091 2009  to  Thu Feb 26 18:26:46.091 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2947741e-03 -1.1221737e-02 -1.2902319e-03 -1.7406535e-01 -3.9291382e-04 1.2330723e-01

  21  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.337 2009  to  Thu Feb 26 18:26:46.337 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2947741e-03 -1.1221737e-02 -1.2902319e-03 -1.7406535e-01 -3.9291382e-04 1.2330723e-01

  22  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.558 2009  to  Thu Feb 26 18:26:46.558 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.1446896e-03 -1.0263771e-02 -1.1374652e-03 -1.7600513e-01 -2.2674561e-02 1.1144590e-01

  23  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.782 2009  to  Thu Feb 26 18:26:46.782 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.1446896e-03 -1.0263771e-02 -1.1374652e-03 -1.7600513e-01 -2.2674561e-02 1.1144590e-01

  24  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:47.001 2009  to  Thu Feb 26 18:26:47.001 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.9593191e-03 -9.9590719e-03 -9.4497204e-04 -1.9246554e-01 -4.0210724e-02 1.2234926e-01

  25  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:47.226 2009  to  Thu Feb 26 18:26:47.226 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.9593191e-03 -9.9590719e-03 -9.4497204e-04 -1.9246554e-01 -4.0210724e-02 1.2234926e-01

  26  FAILED    PSF        command.applyZernikes                                         Thu Feb 26 19:12:15.526 2009  to  Thu Feb 26 19:12:45.840 2009   ( 30.31) secs
                    right PSF ApplyZernikes failed

  27  FAILED    PSF        command.setZernikes                                           Thu Feb 26 19:12:15.472 2009  to  Thu Feb 26 19:12:45.889 2009   ( 30.42) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  28  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 19:12:15.631 2009  to  Thu Feb 26 19:12:45.816 2009   ( 30.18) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 19:12:18.647 2009  to  Thu Feb 26 19:12:45.790 2009   ( 27.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  30  FAILED    PSF        command.applyZernikes                                         Thu Feb 26 23:09:03.125 2009  to  Thu Feb 26 23:09:09.536 2009   (  6.41) secs
                    left PSF ApplyZernikes failed

  31  FAILED    PSF        command.setZernikes                                           Thu Feb 26 23:09:03.098 2009  to  Thu Feb 26 23:09:09.556 2009   (  6.46) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  32  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:09:03.263 2009  to  Thu Feb 26 23:09:09.515 2009   (  6.25) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  33  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:09:03.418 2009  to  Thu Feb 26 23:09:09.496 2009   (  6.08) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:37.587 2009  to  Thu Feb 26 23:20:39.255 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  35  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 26 23:20:39.182 2009  to  Thu Feb 26 23:20:39.403 2009   (  0.22) secs
                    right PSF SetInstrumentOffsets failed

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:39.255 2009  to  Thu Feb 26 23:20:39.358 2009   (  0.10) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 26 23:20:39.214 2009  to  Thu Feb 26 23:20:39.379 2009   (  0.16) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  38  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:53.685 2009  to  Thu Feb 26 23:20:53.685 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  39  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:15.776 2009  to  Thu Feb 26 23:22:18.592 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  40  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:15.941 2009  to  Thu Feb 26 23:22:18.765 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  41  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:18.592 2009  to  Thu Feb 26 23:22:18.873 2009   (  0.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:18.765 2009  to  Thu Feb 26 23:22:18.852 2009   (  0.09) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:22.079 2009  to  Thu Feb 26 23:22:22.079 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  44  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:22.098 2009  to  Thu Feb 26 23:22:22.098 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  45  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:32.549 2009  to  Thu Feb 26 23:24:32.742 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  46  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:32.712 2009  to  Thu Feb 26 23:24:32.905 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  47  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:32.742 2009  to  Thu Feb 26 23:24:33.020 2009   (  0.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:32.905 2009  to  Thu Feb 26 23:24:32.995 2009   (  0.09) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:38.814 2009  to  Thu Feb 26 23:24:38.814 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  50  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:38.833 2009  to  Thu Feb 26 23:24:38.833 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  51  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:18:34.162 2009  to  Fri Feb 27 00:20:18.769 2009   (104.61) secs
                    right PSF ApplyZernikes failed

  52  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:18:34.144 2009  to  Fri Feb 27 00:20:18.789 2009   (104.64) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  53  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:18:34.237 2009  to  Fri Feb 27 00:20:18.749 2009   (104.51) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:18:34.444 2009  to  Fri Feb 27 00:20:18.724 2009   (104.28) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:22:19.670 2009  to  Fri Feb 27 00:24:22.010 2009   (122.34) secs
                    right PSF ApplyZernikes failed

  56  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:22:19.654 2009  to  Fri Feb 27 00:24:22.033 2009   (122.38) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  57  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:22:19.732 2009  to  Fri Feb 27 00:24:21.988 2009   (122.26) secs
                    right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:22:24.664 2009  to  Fri Feb 27 00:24:21.966 2009   (117.30) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  59  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 00:24:55.397 2009  to  Fri Feb 27 00:26:00.770 2009   ( 65.37) secs
                    right PSF SetInstrumentOffsets failed

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:24:55.478 2009  to  Fri Feb 27 00:26:00.730 2009   ( 65.25) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  61  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 00:24:55.426 2009  to  Fri Feb 27 00:26:00.751 2009   ( 65.33) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  62  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:27:22.678 2009  to  Fri Feb 27 00:27:23.131 2009   (  0.45) secs
                    right PSF ApplyZernikes failed

  63  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:27:22.661 2009  to  Fri Feb 27 00:27:23.152 2009   (  0.49) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  64  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:27:22.736 2009  to  Fri Feb 27 00:27:23.109 2009   (  0.37) secs
                    right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  65  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:27:23.015 2009  to  Fri Feb 27 00:27:23.087 2009   (  0.07) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  66  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 00:27:24.583 2009  to  Fri Feb 27 00:27:24.881 2009   (  0.30) secs
                    right PSF SetInstrumentOffsets failed

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:27:24.688 2009  to  Fri Feb 27 00:27:24.841 2009   (  0.15) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  68  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 00:27:24.636 2009  to  Fri Feb 27 00:27:24.861 2009   (  0.22) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  69  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 06:01:30.284 2009  to  Fri Feb 27 06:01:38.472 2009   (  8.19) secs
                    right PSF SetInstrumentOffsets failed

  70  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 06:01:30.314 2009  to  Fri Feb 27 06:01:38.422 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  71  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 06:01:30.299 2009  to  Fri Feb 27 06:01:38.451 2009   (  8.15) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:01.601 2009  to  Thu Feb 26 17:44:01.601 2009   (  0.00) secs
                    EL bad poly no. 67297: BAD Poly: EL = -3.623907e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:04.659 2009  to  Thu Feb 26 17:44:04.659 2009   (  0.00) secs
                    EL bad poly no. 67342: BAD Poly: EL = -3.622278e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:07.720 2009  to  Thu Feb 26 17:44:07.720 2009   (  0.00) secs
                    EL bad poly no. 67384: BAD Poly: EL = -3.620648e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:10.798 2009  to  Thu Feb 26 17:44:10.798 2009   (  0.00) secs
                    EL bad poly no. 67429: BAD Poly: EL = -3.619007e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:13.809 2009  to  Thu Feb 26 17:44:13.809 2009   (  0.00) secs
                    EL bad poly no. 67471: BAD Poly: EL = -3.617402e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:16.860 2009  to  Thu Feb 26 17:44:16.860 2009   (  0.00) secs
                    EL bad poly no. 67516: BAD Poly: EL = -3.615777e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:19.865 2009  to  Thu Feb 26 17:44:19.865 2009   (  0.00) secs
                    EL bad poly no. 67558: BAD Poly: EL = -3.614175e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:22.900 2009  to  Thu Feb 26 17:44:22.900 2009   (  0.00) secs
                    EL bad poly no. 67602: BAD Poly: EL = -3.612558e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:25.967 2009  to  Thu Feb 26 17:44:25.967 2009   (  0.00) secs
                    EL bad poly no. 67645: BAD Poly: EL = -3.610923e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:28.981 2009  to  Thu Feb 26 17:44:28.981 2009   (  0.00) secs
                    EL bad poly no. 67689: BAD Poly: EL = -3.609316e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:32.022 2009  to  Thu Feb 26 17:44:32.022 2009   (  0.00) secs
                    EL bad poly no. 67731: BAD Poly: EL = -3.607695e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:35.022 2009  to  Thu Feb 26 17:44:35.022 2009   (  0.00) secs
                    EL bad poly no. 67774: BAD Poly: EL = -3.606095e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:38.066 2009  to  Thu Feb 26 17:44:38.066 2009   (  0.00) secs
                    EL bad poly no. 67817: BAD Poly: EL = -3.604472e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:41.097 2009  to  Thu Feb 26 17:44:41.097 2009   (  0.00) secs
                    EL bad poly no. 67861: BAD Poly: EL = -3.602856e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:44.124 2009  to  Thu Feb 26 17:44:44.124 2009   (  0.00) secs
                    EL bad poly no. 67903: BAD Poly: EL = -3.601242e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:47.171 2009  to  Thu Feb 26 17:44:47.171 2009   (  0.00) secs
                    EL bad poly no. 67947: BAD Poly: EL = -3.599616e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:50.211 2009  to  Thu Feb 26 17:44:50.211 2009   (  0.00) secs
                    EL bad poly no. 67989: BAD Poly: EL = -3.597995e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:53.272 2009  to  Thu Feb 26 17:44:53.272 2009   (  0.00) secs
                    EL bad poly no. 68034: BAD Poly: EL = -3.596361e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:56.288 2009  to  Thu Feb 26 17:44:56.288 2009   (  0.00) secs
                    EL bad poly no. 68075: BAD Poly: EL = -3.594753e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:44:59.282 2009  to  Thu Feb 26 17:44:59.282 2009   (  0.00) secs
                    EL bad poly no. 68117: BAD Poly: EL = -3.593155e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:02.308 2009  to  Thu Feb 26 17:45:02.308 2009   (  0.00) secs
                    EL bad poly no. 68158: BAD Poly: EL = -3.591541e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:05.332 2009  to  Thu Feb 26 17:45:05.332 2009   (  0.00) secs
                    EL bad poly no. 68201: BAD Poly: EL = -3.589926e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:08.412 2009  to  Thu Feb 26 17:45:08.412 2009   (  0.00) secs
                    EL bad poly no. 68242: BAD Poly: EL = -3.588283e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:11.437 2009  to  Thu Feb 26 17:45:11.437 2009   (  0.00) secs
                    EL bad poly no. 68285: BAD Poly: EL = -3.586668e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 26 17:45:14.434 2009  to  Thu Feb 26 17:45:14.434 2009   (  0.00) secs
                    EL bad poly no. 68325: BAD Poly: EL = -3.585069e-01 rad. Too low.

  26  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:41.814 2009  to  Thu Feb 26 18:26:41.814 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

  27  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.068 2009  to  Thu Feb 26 18:26:42.068 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

  28  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.286 2009  to  Thu Feb 26 18:26:42.286 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

  29  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.510 2009  to  Thu Feb 26 18:26:42.510 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.6681376e-03 -1.0560721e-02 -1.1474490e-03 -1.3733745e-01 -1.0343552e-02 1.1088133e-01

  30  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.730 2009  to  Thu Feb 26 18:26:42.730 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  31  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:42.948 2009  to  Thu Feb 26 18:26:42.948 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  32  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.172 2009  to  Thu Feb 26 18:26:43.172 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

  33  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.392 2009  to  Thu Feb 26 18:26:43.392 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

  34  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.614 2009  to  Thu Feb 26 18:26:43.614 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  35  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:43.833 2009  to  Thu Feb 26 18:26:43.833 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  36  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.069 2009  to  Thu Feb 26 18:26:44.069 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2864294e-03 -1.0614932e-02 -7.3418021e-04 -1.6177821e-01 -1.4686584e-03 1.3429165e-01

  37  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.294 2009  to  Thu Feb 26 18:26:44.294 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4827671e-03 -1.0256022e-02 -9.5495582e-04 -1.5379977e-01 -2.7877808e-02 1.2178469e-01

  38  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.523 2009  to  Thu Feb 26 18:26:44.523 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  39  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.743 2009  to  Thu Feb 26 18:26:44.743 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.4911118e-03 -1.0862827e-02 -1.5110373e-03 -1.6608691e-01 -2.6803970e-02 1.1080027e-01

  40  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:44.968 2009  to  Thu Feb 26 18:26:44.968 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  41  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.192 2009  to  Thu Feb 26 18:26:45.192 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  42  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.414 2009  to  Thu Feb 26 18:26:45.414 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  43  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.634 2009  to  Thu Feb 26 18:26:45.634 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  44  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:45.869 2009  to  Thu Feb 26 18:26:45.869 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.3300600e-03 -1.0568470e-02 -1.3299584e-03 -1.5954280e-01 -5.1403046e-03 1.0054255e-01

  45  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.091 2009  to  Thu Feb 26 18:26:46.091 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2947741e-03 -1.1221737e-02 -1.2902319e-03 -1.7406535e-01 -3.9291382e-04 1.2330723e-01

  46  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.337 2009  to  Thu Feb 26 18:26:46.337 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.2947741e-03 -1.1221737e-02 -1.2902319e-03 -1.7406535e-01 -3.9291382e-04 1.2330723e-01

  47  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.558 2009  to  Thu Feb 26 18:26:46.558 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.1446896e-03 -1.0263771e-02 -1.1374652e-03 -1.7600513e-01 -2.2674561e-02 1.1144590e-01

  48  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:46.782 2009  to  Thu Feb 26 18:26:46.782 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -7.1446896e-03 -1.0263771e-02 -1.1374652e-03 -1.7600513e-01 -2.2674561e-02 1.1144590e-01

  49  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:47.001 2009  to  Thu Feb 26 18:26:47.001 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.9593191e-03 -9.9590719e-03 -9.4497204e-04 -1.9246554e-01 -4.0210724e-02 1.2234926e-01

  50  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 26 18:26:47.226 2009  to  Thu Feb 26 18:26:47.226 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.9593191e-03 -9.9590719e-03 -9.4497204e-04 -1.9246554e-01 -4.0210724e-02 1.2234926e-01

  51  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:40:57.527 2009  to  Thu Feb 26 18:40:57.527 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:40:57.552 2009  to  Thu Feb 26 18:40:57.552 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:41:04.540 2009  to  Thu Feb 26 18:41:04.540 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:41:04.516 2009  to  Thu Feb 26 18:41:04.516 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Thu Feb 26 18:44:15.821 2009  to  Thu Feb 26 18:44:15.821 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  56  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 18:44:15.798 2009  to  Thu Feb 26 18:44:15.798 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  57  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:00:28.950 2009  to  Thu Feb 26 19:43:15.453 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  58  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:00:29.220 2009  to  Thu Feb 26 19:00:29.220 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  59  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:04:19.431 2009  to  Thu Feb 26 19:04:19.431 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:04:19.413 2009  to  Thu Feb 26 19:04:19.413 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:07:30.208 2009  to  Thu Feb 26 19:07:30.208 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:07:30.175 2009  to  Thu Feb 26 19:07:30.175 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  63  FAILED    IIF        command.sendWavefront                                         Thu Feb 26 19:12:15.441 2009  to  Thu Feb 26 19:12:45.942 2009   ( 30.50) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

  64  FAILED    PSF        command.applyZernikes                                         Thu Feb 26 19:12:15.526 2009  to  Thu Feb 26 19:12:45.840 2009   ( 30.31) secs
                    right PSF ApplyZernikes failed

  65  FAILED    PSF        command.setZernikes                                           Thu Feb 26 19:12:15.472 2009  to  Thu Feb 26 19:12:45.889 2009   ( 30.42) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  66  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 19:12:15.631 2009  to  Thu Feb 26 19:12:45.816 2009   ( 30.18) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 19:12:18.647 2009  to  Thu Feb 26 19:12:45.790 2009   ( 27.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 19:12:18.682 2009  to  Thu Feb 26 19:12:45.753 2009   ( 27.07) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  69  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:12:44.263 2009  to  Thu Feb 26 19:12:44.263 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:12:44.235 2009  to  Thu Feb 26 19:12:44.235 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Thu Feb 26 19:18:16.393 2009  to  Thu Feb 26 19:18:16.393 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 19:18:16.377 2009  to  Thu Feb 26 19:18:16.377 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  73  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:43:15.453 2009  to  Thu Feb 26 19:53:02.804 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  74  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 19:43:15.720 2009  to  Thu Feb 26 19:43:15.720 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  75  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:02:06.299 2009  to  Thu Feb 26 20:02:06.299 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:02:06.278 2009  to  Thu Feb 26 20:02:06.278 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  77  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:06:09.597 2009  to  Thu Feb 26 20:17:12.068 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  78  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:06:09.866 2009  to  Thu Feb 26 20:06:09.866 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  79  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:16:33.015 2009  to  Thu Feb 26 20:16:38.853 2009   (  5.84) secs
                    AzCam server timed out waiting for full CCD readout

  80  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:17:04.267 2009  to  Thu Feb 26 20:17:04.595 2009   (  0.33) secs
                    request to AzCam server for a full CCD readout failed

  81  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:18:33.447 2009  to  Thu Feb 26 20:18:33.447 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:18:33.432 2009  to  Thu Feb 26 20:18:33.432 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  83  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:27:35.447 2009  to  Thu Feb 26 20:27:35.447 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  84  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:27:35.472 2009  to  Thu Feb 26 20:27:35.472 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  85  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:39:29.666 2009  to  Thu Feb 26 20:51:16.349 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  86  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 20:39:29.933 2009  to  Thu Feb 26 20:39:29.933 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  87  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 20:42:35.414 2009  to  Thu Feb 26 20:42:41.171 2009   (  5.76) secs
                    AzCam server timed out waiting for full CCD readout

  88  FAILED    PMC        VxInterface.close                                             Thu Feb 26 20:56:00.109 2009  to  Thu Feb 26 20:56:00.109 2009   (  0.00) secs
                    left PMC Motor closing network connection

  89  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 20:56:00.088 2009  to  Thu Feb 26 20:56:00.088 2009   (  0.00) secs
                    left PMC Motor length error: expected 40, got 96

  90  STARTUP   GCS        startup                                                       Thu Feb 26 21:05:29.100 2009  to  Thu Feb 26 21:05:29.100 2009   (  0.00) secs
                    left GCS subsystem started

  91  STARTUP   GCS        startup                                                       Thu Feb 26 21:07:18.662 2009  to  Thu Feb 26 21:07:18.662 2009   (  0.00) secs
                    left GCS subsystem started

  92  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:09:07.987 2009  to  Thu Feb 26 21:09:07.987 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  93  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:09:07.968 2009  to  Thu Feb 26 21:09:07.968 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  94  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:10:38.172 2009  to  Thu Feb 26 21:10:38.172 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  95  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:10:38.155 2009  to  Thu Feb 26 21:10:38.155 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  96  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:20:06.091 2009  to  Thu Feb 26 21:32:02.409 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  97  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:20:06.359 2009  to  Thu Feb 26 21:20:06.359 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  98  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:20:09.322 2009  to  Thu Feb 26 21:20:15.007 2009   (  5.68) secs
                    AzCam server timed out waiting for full CCD readout

  99  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:21:17.491 2009  to  Thu Feb 26 21:21:20.847 2009   (  3.36) secs
                    AzCam server timed out waiting for full CCD readout

 100  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:09.484 2009  to  Thu Feb 26 21:23:09.615 2009   (  0.13) secs
                    request to AzCam server for a full CCD readout failed

 101  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:17.748 2009  to  Thu Feb 26 21:23:17.902 2009   (  0.15) secs
                    request to AzCam server for a full CCD readout failed

 102  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:26.981 2009  to  Thu Feb 26 21:23:27.088 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 103  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:39.654 2009  to  Thu Feb 26 21:23:39.759 2009   (  0.10) secs
                    request to AzCam server for a full CCD readout failed

 104  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:23:58.374 2009  to  Thu Feb 26 21:23:58.491 2009   (  0.12) secs
                    request to AzCam server for a full CCD readout failed

 105  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:25:10.540 2009  to  Thu Feb 26 21:25:10.633 2009   (  0.09) secs
                    request to AzCam server for a full CCD readout failed

 106  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:27:35.737 2009  to  Thu Feb 26 21:27:35.842 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 107  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:27:55.897 2009  to  Thu Feb 26 21:27:56.015 2009   (  0.12) secs
                    request to AzCam server for a full CCD readout failed

 108  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:28:34.636 2009  to  Thu Feb 26 21:28:34.742 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 109  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:33:45.445 2009  to  Thu Feb 26 21:33:45.445 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 110  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:33:45.462 2009  to  Thu Feb 26 21:33:45.462 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 111  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 21:36:56.608 2009  to  Thu Feb 26 21:36:56.608 2009   (  0.00) secs
                    left GCS ShutDown Command Started

 112  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 21:36:57.963 2009  to  Thu Feb 26 21:36:57.963 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

 113  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:38:49.217 2009  to  Thu Feb 26 21:38:49.217 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 114  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:38:49.198 2009  to  Thu Feb 26 21:38:49.198 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 115  STARTUP   GCS        startup                                                       Thu Feb 26 21:39:52.477 2009  to  Thu Feb 26 21:39:52.477 2009   (  0.00) secs
                    left GCS subsystem started

 116  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:41:04.392 2009  to  Thu Feb 26 21:41:10.416 2009   (  6.02) secs
                    AzCam server timed out waiting for full CCD readout

 117  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:41:24.820 2009  to  Thu Feb 26 21:41:24.926 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 118  STARTUP   GCS        startup                                                       Thu Feb 26 21:41:49.575 2009  to  Thu Feb 26 21:41:49.575 2009   (  0.00) secs
                    left GCS subsystem started

 119  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:49:21.646 2009  to  Thu Feb 26 21:49:27.354 2009   (  5.71) secs
                    AzCam server timed out waiting for full CCD readout

 120  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 21:49:40.694 2009  to  Thu Feb 26 21:49:40.828 2009   (  0.13) secs
                    request to AzCam server for a full CCD readout failed

 121  STARTUP   GCS        startup                                                       Thu Feb 26 21:50:55.181 2009  to  Thu Feb 26 21:50:55.181 2009   (  0.00) secs
                    left GCS subsystem started

 122  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:57:44.988 2009  to  Thu Feb 26 21:57:50.901 2009   (  5.91) secs
                    AzCam server timed out waiting for full CCD readout

 123  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:58:42.332 2009  to  Thu Feb 26 22:26:48.092 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 124  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 21:58:42.600 2009  to  Thu Feb 26 21:58:42.600 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 125  FAILED    PMC        VxInterface.close                                             Thu Feb 26 21:58:54.831 2009  to  Thu Feb 26 21:58:54.831 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 126  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 21:58:54.816 2009  to  Thu Feb 26 21:58:54.816 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 127  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:59:01.879 2009  to  Thu Feb 26 21:59:07.898 2009   (  6.02) secs
                    AzCam server timed out waiting for full CCD readout

 128  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 21:59:23.069 2009  to  Thu Feb 26 21:59:23.176 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 129  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:03:26.392 2009  to  Thu Feb 26 22:03:26.392 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 130  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:03:26.375 2009  to  Thu Feb 26 22:03:26.375 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 131  FAILED    GCS        command.getFullWFImage                                        Thu Feb 26 22:04:28.152 2009  to  Thu Feb 26 22:04:28.257 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 132  STARTUP   GCS        startup                                                       Thu Feb 26 22:06:12.754 2009  to  Thu Feb 26 22:06:12.754 2009   (  0.00) secs
                    left GCS subsystem started

 133  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:09:49.367 2009  to  Thu Feb 26 22:09:55.058 2009   (  5.69) secs
                    AzCam server timed out waiting for full CCD readout

 134  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:10:32.163 2009  to  Thu Feb 26 22:10:32.224 2009   (  0.06) secs
                    request to AzCam server for a full CCD readout failed

 135  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:10:37.389 2009  to  Thu Feb 26 22:10:37.489 2009   (  0.10) secs
                    request to AzCam server for a full CCD readout failed

 136  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:11:21.705 2009  to  Thu Feb 26 22:11:21.810 2009   (  0.11) secs
                    request to AzCam server for a full CCD readout failed

 137  FAILED    GCS        command.getFullGuideImage                                     Thu Feb 26 22:16:02.032 2009  to  Thu Feb 26 22:16:02.125 2009   (  0.09) secs
                    request to AzCam server for a full CCD readout failed

 138  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 22:16:13.384 2009  to  Thu Feb 26 22:16:13.384 2009   (  0.00) secs
                    left GCS ShutDown Command Started

 139  SHUTDOWN  GCS        command.shutdown                                              Thu Feb 26 22:16:14.560 2009  to  Thu Feb 26 22:16:14.560 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

 140  STARTUP   GCS        startup                                                       Thu Feb 26 22:16:50.012 2009  to  Thu Feb 26 22:16:50.012 2009   (  0.00) secs
                    left GCS subsystem started

 141  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:22:47.318 2009  to  Thu Feb 26 22:22:47.318 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 142  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:22:47.300 2009  to  Thu Feb 26 22:22:47.300 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 143  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:38:22.469 2009  to  Thu Feb 26 22:38:22.469 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:38:22.452 2009  to  Thu Feb 26 22:38:22.452 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 145  FAILED    PMC        VxInterface.close                                             Thu Feb 26 22:48:49.085 2009  to  Thu Feb 26 22:48:49.085 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 22:48:49.064 2009  to  Thu Feb 26 22:48:49.064 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 147  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:05:24.019 2009  to  Thu Feb 26 23:05:24.019 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:05:24.006 2009  to  Thu Feb 26 23:05:24.006 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 149  FAILED    IIF        command.sendWavefront                                         Thu Feb 26 23:09:03.066 2009  to  Thu Feb 26 23:09:09.597 2009   (  6.53) secs
                    IIF Guide command started for right LBC, coord1 8.677418826079772e-07, coord2 1.682495302043813e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 150  FAILED    PSF        command.applyZernikes                                         Thu Feb 26 23:09:03.125 2009  to  Thu Feb 26 23:09:09.536 2009   (  6.41) secs
                    left PSF ApplyZernikes failed

 151  FAILED    PSF        command.setZernikes                                           Thu Feb 26 23:09:03.098 2009  to  Thu Feb 26 23:09:09.556 2009   (  6.46) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 152  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:09:03.263 2009  to  Thu Feb 26 23:09:09.515 2009   (  6.25) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 153  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:09:03.444 2009  to  Thu Feb 26 23:09:09.469 2009   (  6.02) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 154  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:09:03.418 2009  to  Thu Feb 26 23:09:09.496 2009   (  6.08) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 155  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:09:28.193 2009  to  Thu Feb 26 23:09:28.193 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 156  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:09:28.176 2009  to  Thu Feb 26 23:09:28.176 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 157  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:37.612 2009  to  Thu Feb 26 23:20:39.302 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 158  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:37.587 2009  to  Thu Feb 26 23:20:39.255 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 159  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 26 23:20:39.182 2009  to  Thu Feb 26 23:20:39.403 2009   (  0.22) secs
                    right PSF SetInstrumentOffsets failed

 160  FAILED    IIF        command.moveFocus                                             Thu Feb 26 23:20:39.118 2009  to  Thu Feb 26 23:20:39.469 2009   (  0.35) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

 161  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:39.255 2009  to  Thu Feb 26 23:20:39.358 2009   (  0.10) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 162  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 26 23:20:39.214 2009  to  Thu Feb 26 23:20:39.379 2009   (  0.16) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 163  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:39.302 2009  to  Thu Feb 26 23:20:39.324 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 164  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:20:53.655 2009  to  Thu Feb 26 23:20:53.655 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 165  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:20:53.685 2009  to  Thu Feb 26 23:20:53.685 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 166  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:15.776 2009  to  Thu Feb 26 23:22:18.592 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

 167  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:15.941 2009  to  Thu Feb 26 23:22:18.765 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 168  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:15.981 2009  to  Thu Feb 26 23:22:18.790 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 169  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:18.592 2009  to  Thu Feb 26 23:22:18.873 2009   (  0.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 170  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:18.790 2009  to  Thu Feb 26 23:22:18.806 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 171  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:18.765 2009  to  Thu Feb 26 23:22:18.852 2009   (  0.09) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 172  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:22:22.048 2009  to  Thu Feb 26 23:22:22.048 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 173  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:22:22.079 2009  to  Thu Feb 26 23:22:22.079 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 174  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:22:22.098 2009  to  Thu Feb 26 23:22:22.098 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

 175  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:22:52.146 2009  to  Thu Feb 26 23:22:52.146 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 176  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:22:52.168 2009  to  Thu Feb 26 23:22:52.168 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 177  FAILED    PMC        VxInterface.packetReadError                                   Thu Feb 26 23:24:15.509 2009  to  Thu Feb 26 23:24:15.509 2009   (  0.00) secs
                    left PMC PMCLogger packet read error: 5002

 178  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:15.492 2009  to  Thu Feb 26 23:24:15.492 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 179  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:15.835 2009  to  Thu Feb 26 23:24:15.835 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 180  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:16.154 2009  to  Thu Feb 26 23:24:16.154 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 181  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 26 23:24:16.480 2009  to  Thu Feb 26 23:24:16.480 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 182  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:32.549 2009  to  Thu Feb 26 23:24:32.742 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

 183  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:32.712 2009  to  Thu Feb 26 23:24:32.905 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 184  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:32.745 2009  to  Thu Feb 26 23:24:32.934 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 185  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:32.742 2009  to  Thu Feb 26 23:24:33.020 2009   (  0.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 186  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:32.934 2009  to  Thu Feb 26 23:24:32.948 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 187  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:32.905 2009  to  Thu Feb 26 23:24:32.995 2009   (  0.09) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 188  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 26 23:24:38.785 2009  to  Thu Feb 26 23:24:38.785 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 189  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 26 23:24:38.814 2009  to  Thu Feb 26 23:24:38.814 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 190  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 26 23:24:38.833 2009  to  Thu Feb 26 23:24:38.833 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

 191  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 26 23:30:03.265 2009  to  Thu Feb 26 23:30:03.265 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 192  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 26 23:30:03.333 2009  to  Thu Feb 26 23:30:03.333 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 193  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 23:33:15.449 2009  to  Thu Feb 26 23:43:11.879 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 194  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 26 23:33:15.713 2009  to  Thu Feb 26 23:33:15.713 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 195  FAILED    PMC        VxInterface.close                                             Thu Feb 26 23:43:14.678 2009  to  Thu Feb 26 23:43:14.678 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 196  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 26 23:43:14.661 2009  to  Thu Feb 26 23:43:14.661 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 197  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Feb 26 23:45:44.490 2009  to  Thu Feb 26 23:45:44.490 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

 198  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Thu Feb 26 23:55:33.744 2009  to  Thu Feb 26 23:55:33.744 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

 199  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 00:12:32.140 2009  to  Fri Feb 27 00:12:32.140 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 200  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 00:12:32.182 2009  to  Fri Feb 27 00:12:32.182 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 201  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:18:34.108 2009  to  Fri Feb 27 00:20:18.826 2009   (104.72) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 202  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:18:34.162 2009  to  Fri Feb 27 00:20:18.769 2009   (104.61) secs
                    right PSF ApplyZernikes failed

 203  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:18:34.144 2009  to  Fri Feb 27 00:20:18.789 2009   (104.64) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 204  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:18:34.237 2009  to  Fri Feb 27 00:20:18.749 2009   (104.51) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 205  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:18:34.444 2009  to  Fri Feb 27 00:20:18.724 2009   (104.28) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 206  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:18:34.469 2009  to  Fri Feb 27 00:20:18.682 2009   (104.21) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 207  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:22:19.670 2009  to  Fri Feb 27 00:24:22.010 2009   (122.34) secs
                    right PSF ApplyZernikes failed

 208  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:22:19.654 2009  to  Fri Feb 27 00:24:22.033 2009   (122.38) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 209  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:22:19.618 2009  to  Fri Feb 27 00:24:22.095 2009   (122.48) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 210  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:22:19.732 2009  to  Fri Feb 27 00:24:21.988 2009   (122.26) secs
                    right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

 211  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:22:24.690 2009  to  Fri Feb 27 00:24:21.937 2009   (117.25) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 212  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:22:24.664 2009  to  Fri Feb 27 00:24:21.966 2009   (117.30) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 213  FAILED    IIF        command.moveFocus                                             Fri Feb 27 00:24:55.354 2009  to  Fri Feb 27 00:26:00.889 2009   ( 65.53) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488930898148148e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 214  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 00:24:55.397 2009  to  Fri Feb 27 00:26:00.770 2009   ( 65.37) secs
                    right PSF SetInstrumentOffsets failed

 215  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:24:55.478 2009  to  Fri Feb 27 00:26:00.730 2009   ( 65.25) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 216  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 00:24:55.426 2009  to  Fri Feb 27 00:26:00.751 2009   ( 65.33) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 217  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:24:55.540 2009  to  Fri Feb 27 00:26:00.694 2009   ( 65.15) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 218  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:26:29.493 2009  to  Fri Feb 27 00:26:29.493 2009   (  0.00) secs
                    right PMC ** PANIC: Hardpoint breakaway

 219  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:33.823 2009  to  Fri Feb 27 00:26:33.823 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 22)

 220  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:33.881 2009  to  Fri Feb 27 00:26:33.881 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 23)

 221  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.149 2009  to  Fri Feb 27 00:26:34.149 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 24)

 222  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.198 2009  to  Fri Feb 27 00:26:34.198 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 25)

 223  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.475 2009  to  Fri Feb 27 00:26:34.475 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 26)

 224  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.780 2009  to  Fri Feb 27 00:26:34.780 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 27)

 225  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:34.794 2009  to  Fri Feb 27 00:26:34.794 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 28)

 226  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.067 2009  to  Fri Feb 27 00:26:35.067 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 29)

 227  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.119 2009  to  Fri Feb 27 00:26:35.119 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 30)

 228  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.393 2009  to  Fri Feb 27 00:26:35.393 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 31)

 229  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.410 2009  to  Fri Feb 27 00:26:35.410 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 32)

 230  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.682 2009  to  Fri Feb 27 00:26:35.682 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 33)

 231  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.696 2009  to  Fri Feb 27 00:26:35.696 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 34)

 232  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:35.971 2009  to  Fri Feb 27 00:26:35.971 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 35)

 233  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.240 2009  to  Fri Feb 27 00:26:36.240 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 36)

 234  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.325 2009  to  Fri Feb 27 00:26:36.325 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 37)

 235  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.604 2009  to  Fri Feb 27 00:26:36.604 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 38)

 236  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.621 2009  to  Fri Feb 27 00:26:36.621 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 39)

 237  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.889 2009  to  Fri Feb 27 00:26:36.889 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 40)

 238  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:36.915 2009  to  Fri Feb 27 00:26:36.915 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 41)

 239  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.184 2009  to  Fri Feb 27 00:26:37.184 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 42)

 240  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.258 2009  to  Fri Feb 27 00:26:37.258 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 43)

 241  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.526 2009  to  Fri Feb 27 00:26:37.526 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 44)

 242  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.539 2009  to  Fri Feb 27 00:26:37.539 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 45)

 243  FAILED    PMC        actuator.neighborCheck.tripped                                Fri Feb 27 00:26:37.812 2009  to  Fri Feb 27 00:26:37.812 2009   (  0.00) secs
                    right PMC Actuator 335 near neighbor force check failed, (count = 46)

 244  FAILED    PSF        command.applyZernikes                                         Fri Feb 27 00:27:22.678 2009  to  Fri Feb 27 00:27:23.131 2009   (  0.45) secs
                    right PSF ApplyZernikes failed

 245  FAILED    PSF        command.setZernikes                                           Fri Feb 27 00:27:22.661 2009  to  Fri Feb 27 00:27:23.152 2009   (  0.49) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 246  FAILED    IIF        command.sendWavefront                                         Fri Feb 27 00:27:22.629 2009  to  Fri Feb 27 00:27:23.209 2009   (  0.58) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF SendWavefront command failed for right LBC for M1

 247  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 27 00:27:22.736 2009  to  Fri Feb 27 00:27:23.109 2009   (  0.37) secs
                    right PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

 248  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:27:23.040 2009  to  Fri Feb 27 00:27:23.055 2009   (  0.01) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 249  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:27:23.015 2009  to  Fri Feb 27 00:27:23.087 2009   (  0.07) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 250  FAILED    IIF        command.moveFocus                                             Fri Feb 27 00:27:24.515 2009  to  Fri Feb 27 00:27:24.952 2009   (  0.44) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 251  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 00:27:24.583 2009  to  Fri Feb 27 00:27:24.881 2009   (  0.30) secs
                    right PSF SetInstrumentOffsets failed

 252  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 00:27:24.688 2009  to  Fri Feb 27 00:27:24.841 2009   (  0.15) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 253  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 00:27:24.636 2009  to  Fri Feb 27 00:27:24.861 2009   (  0.22) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 254  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 00:27:24.750 2009  to  Fri Feb 27 00:27:24.795 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 255  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 27 00:28:51.641 2009  to  Fri Feb 27 00:29:39.797 2009   ( 48.16) secs
                    right PMC Actuator 101 get force read error: -3
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 256  FAILED    PMC        mirror.autoRaiseRaiseTimeOut                                  Fri Feb 27 00:29:39.210 2009  to  Fri Feb 27 00:29:39.210 2009   (  0.00) secs
                    right PMC Auto-raise time-out: raise failed to finish in alloted time

 257  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:29:39.296 2009  to  Fri Feb 27 00:29:39.296 2009   (  0.00) secs
                    right PMC Actuator 434 set force read error: -3

 258  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:29:39.243 2009  to  Fri Feb 27 00:29:39.243 2009   (  0.00) secs
                    right PMC ** PANIC: User Button

 259  FAILED    PMC        actuator.getForce.readError                                   Fri Feb 27 00:29:39.322 2009  to  Fri Feb 27 00:29:39.322 2009   (  0.00) secs
                    right PMC Actuator 101 get force read error: -3
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 260  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:29:41.390 2009  to  Fri Feb 27 00:29:41.390 2009   (  0.00) secs
                    right PMC Actuator 337 set force bad return: 173 instead of 16

 261  FAILED    PMC        actuator.getForce.readError                                   Fri Feb 27 00:29:41.695 2009  to  Fri Feb 27 00:29:41.695 2009   (  0.00) secs
                    right PMC Actuator 211 get force read error: -3

 262  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.709 2009  to  Fri Feb 27 00:29:41.709 2009   (  0.00) secs
                    right PMC Actuator 421 has been reset

 263  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:29:41.681 2009  to  Fri Feb 27 00:29:41.681 2009   (  0.00) secs
                    right PMC Actuator 338 set force read error: -3

 264  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.738 2009  to  Fri Feb 27 00:29:41.738 2009   (  0.00) secs
                    right PMC Actuator 419 has been reset

 265  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.752 2009  to  Fri Feb 27 00:29:41.752 2009   (  0.00) secs
                    right PMC Actuator 417 has been reset

 266  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.778 2009  to  Fri Feb 27 00:29:41.778 2009   (  0.00) secs
                    right PMC Actuator 441 has been reset

 267  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.805 2009  to  Fri Feb 27 00:29:41.805 2009   (  0.00) secs
                    right PMC Actuator 415 has been reset

 268  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.821 2009  to  Fri Feb 27 00:29:41.821 2009   (  0.00) secs
                    right PMC Actuator 429 has been reset

 269  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.846 2009  to  Fri Feb 27 00:29:41.846 2009   (  0.00) secs
                    right PMC Actuator 422 has been reset

 270  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.862 2009  to  Fri Feb 27 00:29:41.862 2009   (  0.00) secs
                    right PMC Actuator 425 has been reset

 271  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.879 2009  to  Fri Feb 27 00:29:41.879 2009   (  0.00) secs
                    right PMC Actuator 426 has been reset

 272  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.893 2009  to  Fri Feb 27 00:29:41.893 2009   (  0.00) secs
                    right PMC Actuator 439 has been reset

 273  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.911 2009  to  Fri Feb 27 00:29:41.911 2009   (  0.00) secs
                    right PMC Actuator 427 has been reset

 274  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.948 2009  to  Fri Feb 27 00:29:41.948 2009   (  0.00) secs
                    right PMC Actuator 428 has been reset

 275  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.979 2009  to  Fri Feb 27 00:29:41.979 2009   (  0.00) secs
                    right PMC Actuator 431 has been reset

 276  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:41.995 2009  to  Fri Feb 27 00:29:41.995 2009   (  0.00) secs
                    right PMC Actuator 440 has been reset

 277  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.015 2009  to  Fri Feb 27 00:29:42.015 2009   (  0.00) secs
                    right PMC Actuator 436 has been reset

 278  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.048 2009  to  Fri Feb 27 00:29:42.048 2009   (  0.00) secs
                    right PMC Actuator 437 has been reset

 279  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.079 2009  to  Fri Feb 27 00:29:42.079 2009   (  0.00) secs
                    right PMC Actuator 443 has been reset

 280  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.095 2009  to  Fri Feb 27 00:29:42.095 2009   (  0.00) secs
                    right PMC Actuator 442 has been reset

 281  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.388 2009  to  Fri Feb 27 00:29:42.388 2009   (  0.00) secs
                    right PMC Actuator 411 has been reset

 282  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.416 2009  to  Fri Feb 27 00:29:42.416 2009   (  0.00) secs
                    right PMC Actuator 424 has been reset

 283  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:29:42.369 2009  to  Fri Feb 27 00:29:42.369 2009   (  0.00) secs
                    right PMC Actuator 410 set force bad return: 171 instead of 16

 284  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.437 2009  to  Fri Feb 27 00:29:42.437 2009   (  0.00) secs
                    right PMC Actuator 420 has been reset

 285  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.463 2009  to  Fri Feb 27 00:29:42.463 2009   (  0.00) secs
                    right PMC Actuator 434 has been reset

 286  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.481 2009  to  Fri Feb 27 00:29:42.481 2009   (  0.00) secs
                    right PMC Actuator 430 has been reset

 287  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.497 2009  to  Fri Feb 27 00:29:42.497 2009   (  0.00) secs
                    right PMC Actuator 438 has been reset

 288  FAILED    PMC        actuator.reset                                                Fri Feb 27 00:29:42.514 2009  to  Fri Feb 27 00:29:42.514 2009   (  0.00) secs
                    right PMC Actuator 339 has been reset

 289  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:30:23.196 2009  to  Fri Feb 27 00:30:23.196 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 290  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:30:27.685 2009  to  Fri Feb 27 00:30:27.685 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 291  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:31:14.528 2009  to  Fri Feb 27 00:31:14.528 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 292  FAILED    PMC        mirror.command.unPause                                        Fri Feb 27 00:32:37.065 2009  to  Fri Feb 27 00:32:37.090 2009   (  0.02) secs
                    right PMC Mirror UnPause Command Started
                    right PMC Mirror UnPause Command Failed because Wrong mirror state

 293  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 27 00:34:00.010 2009  to  Fri Feb 27 00:38:26.574 2009   (266.56) secs
                    right PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 294  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 00:34:16.217 2009  to  Fri Feb 27 00:34:16.217 2009   (  0.00) secs
                    

 295  FAILED    PMC        mirror.panic                                                  Fri Feb 27 00:38:26.409 2009  to  Fri Feb 27 00:38:26.409 2009   (  0.00) secs
                    right PMC ** PANIC: Hardpoint breakaway

 296  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:38:28.491 2009  to  Fri Feb 27 00:38:28.491 2009   (  0.00) secs
                    right PMC Actuator 112 set force bad return: 179 instead of 2

 297  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:38:28.761 2009  to  Fri Feb 27 00:38:28.761 2009   (  0.00) secs
                    right PMC Actuator 118 set force read error: -3

 298  FAILED    PMC        actuator.setForce.addressError                                Fri Feb 27 00:38:29.051 2009  to  Fri Feb 27 00:38:29.051 2009   (  0.00) secs
                    right PMC Actuator 117 set force bad return: 244 instead of 3

 299  FAILED    PMC        actuator.setForce.readError                                   Fri Feb 27 00:38:29.033 2009  to  Fri Feb 27 00:38:29.033 2009   (  0.00) secs
                    right PMC Actuator 122 set force read error: -3

 300  FAILED    PMC        command.recoverPanic                                          Fri Feb 27 00:38:35.690 2009  to  Fri Feb 27 00:38:35.706 2009   (  0.02) secs
                    right PMC RecoverPanic Command Started
                    right PMC RecoverPanic Command Failed because Wrong mirror state

 301  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 00:45:13.971 2009  to  Fri Feb 27 00:45:13.971 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 302  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 00:48:32.372 2009  to  Fri Feb 27 00:48:32.372 2009   (  0.00) secs
                    

 303  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 01:06:04.389 2009  to  Fri Feb 27 03:26:39.032 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 304  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 01:06:04.659 2009  to  Fri Feb 27 01:06:04.659 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 305  SXDXBOTH  MCS.MCSPU  MCSPU.eventQueueFull                                          Fri Feb 27 01:08:50.828 2009  to  Fri Feb 27 01:08:50.828 2009   (  0.00) secs
                    

 306  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:28:56.645 2009  to  Fri Feb 27 01:28:56.645 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 307  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:29:44.530 2009  to  Fri Feb 27 01:29:44.530 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 308  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:29:53.235 2009  to  Fri Feb 27 01:29:53.235 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 309  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:31:15.200 2009  to  Fri Feb 27 01:31:15.200 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 310  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:32:34.633 2009  to  Fri Feb 27 01:32:34.633 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 311  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:33:15.927 2009  to  Fri Feb 27 01:33:15.927 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 312  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:34:51.352 2009  to  Fri Feb 27 01:34:51.352 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 313  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:35:17.188 2009  to  Fri Feb 27 01:35:17.188 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 314  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:35:30.104 2009  to  Fri Feb 27 01:35:30.104 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 315  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.346 2009  to  Fri Feb 27 01:38:33.346 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 316  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.347 2009  to  Fri Feb 27 01:38:33.347 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 317  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:33.348 2009  to  Fri Feb 27 01:38:33.348 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 318  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.507 2009  to  Fri Feb 27 01:38:49.507 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 319  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.508 2009  to  Fri Feb 27 01:38:49.508 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 320  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:38:49.563 2009  to  Fri Feb 27 01:38:49.563 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 321  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.610 2009  to  Fri Feb 27 01:39:07.610 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 322  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.665 2009  to  Fri Feb 27 01:39:07.665 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 323  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:39:07.667 2009  to  Fri Feb 27 01:39:07.667 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 324  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:52:20.651 2009  to  Fri Feb 27 01:52:20.651 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 325  FAILED    MCS.MCSPU  MCSPU.Main.termination                                        Fri Feb 27 01:56:05.780 2009  to  Fri Feb 27 01:56:05.780 2009   (  0.00) secs
                    Main program is terminating.

 326  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 01:56:51.680 2009  to  Fri Feb 27 01:56:51.680 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 327  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 01:56:51.689 2009  to  Fri Feb 27 01:56:51.689 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 328  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 01:56:51.785 2009  to  Fri Feb 27 01:56:51.785 2009   (  0.00) secs
                    drive cabinet has turned on.

 329  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.294 2009  to  Fri Feb 27 01:56:52.294 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 330  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.294 2009  to  Fri Feb 27 01:56:52.294 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 331  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.295 2009  to  Fri Feb 27 01:56:52.295 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 332  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.295 2009  to  Fri Feb 27 01:56:52.295 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 333  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.296 2009  to  Fri Feb 27 01:56:52.296 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 334  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.296 2009  to  Fri Feb 27 01:56:52.296 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 335  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.297 2009  to  Fri Feb 27 01:56:52.297 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 336  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 01:56:52.298 2009  to  Fri Feb 27 01:56:52.298 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 337  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.676 2009  to  Fri Feb 27 01:58:28.676 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 338  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.677 2009  to  Fri Feb 27 01:58:28.677 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 339  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 01:58:28.786 2009  to  Fri Feb 27 01:58:28.786 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 340  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 01:59:18.172 2009  to  Fri Feb 27 01:59:18.172 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 341  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:09:56.338 2009  to  Fri Feb 27 02:09:56.338 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 342  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:09:56.345 2009  to  Fri Feb 27 02:09:56.345 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 343  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:09:56.443 2009  to  Fri Feb 27 02:09:56.443 2009   (  0.00) secs
                    drive cabinet has turned on.

 344  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.962 2009  to  Fri Feb 27 02:09:56.962 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 345  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.962 2009  to  Fri Feb 27 02:09:56.962 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 346  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.963 2009  to  Fri Feb 27 02:09:56.963 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 347  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.963 2009  to  Fri Feb 27 02:09:56.963 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 348  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.964 2009  to  Fri Feb 27 02:09:56.964 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 349  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 350  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 351  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:09:56.965 2009  to  Fri Feb 27 02:09:56.965 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 352  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 02:10:32.614 2009  to  Fri Feb 27 02:10:32.614 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 353  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 27 02:21:27.436 2009  to  Fri Feb 27 02:21:27.436 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

 354  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet2                                   Fri Feb 27 02:22:41.100 2009  to  Fri Feb 27 02:22:41.100 2009   (  0.00) secs
                    Tried to set brakes a second time and they failed to set again.

 355  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Feb 27 02:22:41.099 2009  to  Fri Feb 27 02:22:41.099 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 356  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:24:28.072 2009  to  Fri Feb 27 02:24:28.072 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 357  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:24:28.079 2009  to  Fri Feb 27 02:24:28.079 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 358  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:24:28.176 2009  to  Fri Feb 27 02:24:28.176 2009   (  0.00) secs
                    drive cabinet has turned on.

 359  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 360  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 361  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.691 2009  to  Fri Feb 27 02:24:28.691 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 362  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.692 2009  to  Fri Feb 27 02:24:28.692 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 363  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.693 2009  to  Fri Feb 27 02:24:28.693 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 364  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.693 2009  to  Fri Feb 27 02:24:28.693 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 365  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.694 2009  to  Fri Feb 27 02:24:28.694 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 366  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:24:28.694 2009  to  Fri Feb 27 02:24:28.694 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 367  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:30:29.846 2009  to  Fri Feb 27 02:30:29.846 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 368  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:30:29.850 2009  to  Fri Feb 27 02:30:29.850 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 369  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:30:29.944 2009  to  Fri Feb 27 02:30:29.944 2009   (  0.00) secs
                    drive cabinet has turned on.

 370  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Feb 27 02:30:30.461 2009  to  Fri Feb 27 02:30:30.461 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 371  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:37:12.359 2009  to  Fri Feb 27 02:37:12.359 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 372  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 02:37:12.367 2009  to  Fri Feb 27 02:37:12.367 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 373  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Feb 27 02:37:12.465 2009  to  Fri Feb 27 02:37:12.465 2009   (  0.00) secs
                    drive cabinet has turned on.

 374  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 27 03:37:53.248 2009  to  Fri Feb 27 03:37:53.248 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 375  FAILED    PMC        VxInterface.close                                             Fri Feb 27 03:37:53.274 2009  to  Fri Feb 27 03:37:53.274 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 376  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 05:11:19.449 2009  to  Fri Feb 27 05:20:03.342 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 377  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 05:11:19.716 2009  to  Fri Feb 27 05:11:19.716 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 378  FAILED    IIF        command.moveFocus                                             Fri Feb 27 06:01:30.263 2009  to  Fri Feb 27 06:01:38.538 2009   (  8.28) secs
                    IIF MoveFocus command started for right LBC for 2.390000000000000e-01
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 2.390000000000000e-01

 379  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 27 06:01:30.342 2009  to  Fri Feb 27 06:01:38.373 2009   (  8.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 380  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 27 06:01:30.284 2009  to  Fri Feb 27 06:01:38.472 2009   (  8.19) secs
                    right PSF SetInstrumentOffsets failed

 381  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 27 06:01:30.314 2009  to  Fri Feb 27 06:01:38.422 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 382  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 27 06:01:30.299 2009  to  Fri Feb 27 06:01:38.451 2009   (  8.15) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 383  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:08:56.384 2009  to  Fri Feb 27 06:09:28.147 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 384  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:08:56.652 2009  to  Fri Feb 27 06:08:56.652 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 385  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 27 06:09:28.414 2009  to  Fri Feb 27 06:09:28.414 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 386  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Fri Feb 27 06:47:37.363 2009  to  Fri Feb 27 06:47:37.363 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

 387  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Feb 27 06:47:40.902 2009  to  Fri Feb 27 06:47:40.902 2009   (  0.00) secs
                    Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 388  FAILED    MCS.MCSPU  MCSPU.AZDrive.mcrProblem                                      Fri Feb 27 06:47:41.011 2009  to  Fri Feb 27 06:47:41.011 2009   (  0.00) secs
                    Master Ctrl Relay has opened because AZ MCR is off: Left Bumper limit!

 389  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Fri Feb 27 06:48:46.989 2009  to  Fri Feb 27 06:48:46.989 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 390  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 06:48:47.318 2009  to  Fri Feb 27 06:48:47.318 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 391  FAILED    MCS.MCSPU  MCSPU.Brake.unsuccessfulCompletion                            Fri Feb 27 06:48:47.372 2009  to  Fri Feb 27 06:48:47.372 2009   (  0.00) secs
                    A brake command failed to complete successfully.

 392  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Fri Feb 27 06:48:48.995 2009  to  Fri Feb 27 06:48:48.995 2009   (  0.00) secs
                    Cannot set all brakes or release all brakes.

 393  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 07:10:02.928 2009  to  Fri Feb 27 07:10:02.928 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 394  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Feb 27 07:10:02.933 2009  to  Fri Feb 27 07:10:02.933 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

**********************************************************
    Reporting period ending:   Fri Feb 27 07:19:53.748 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback