             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = ecs.lights.command.enable.complete,  priority = 0, 2
      event = ecs.lights.command.disable.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.08   100.0 %        127        127                      
                                                                       0.01    0.03    0.02    0.08
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.27    0.36    0.13    1.76   100.0 %        312        312                      
                                                                       0.27    0.36    0.13    1.76
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.04    0.08    0.06    0.40   100.0 %        342        342                      
                                                                       0.04    0.08    0.06    0.40
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.81    5.82    0.50   70.60    99.7 %        311        310          1           
                                                                       6.82    5.84    2.30   70.60
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    4.08    5.11    0.00   28.73   100.0 %         49         49                      
                                                                       4.02    5.32    2.87   28.73
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    4.09    4.38    0.00   28.11   100.0 %         49         49                      
                                                                       4.07    4.57    2.02   28.11
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   23.77   17.50    1.02   58.15   100.0 %         15         15                      
                                                                      23.77   17.50    1.02   58.15
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   45.12   19.37    0.00  166.36   100.0 %         15         15                      
                                                                      46.49   20.75    1.02  166.36
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   43.07   27.53    0.00  135.10    80.0 %         15         12                     3
                                                                      44.25   30.03    7.97  135.10
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    4.88    5.14    0.41   74.67    99.5 %        573        570          3           
                                                                       4.86    5.11    0.41   74.67
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.94    4.42    2.29   11.48    96.2 %         53         51          2           
                                                                       1.63    4.22    2.29    6.53

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            12

IIF Events of Interest

   1  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:22:33.009 2009  to  Tue Feb 24 18:23:31.730 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

   2  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:22:33.729 2009  to  Tue Feb 24 18:23:31.925 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command wait for telescope started for both LBC

   3  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:23:31.730 2009  to  Tue Feb 24 18:24:20.150 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

   4  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:23:31.925 2009  to  Tue Feb 24 18:24:20.741 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command wait for telescope started for both LBC

   5  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:24:49.039 2009  to  Tue Feb 24 18:24:49.039 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

   6  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:24:49.024 2009  to  Tue Feb 24 18:24:49.024 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command wait for telescope complete for both LBC

   7  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:24:49.129 2009  to  Tue Feb 24 18:24:49.129 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

   8  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:24:49.091 2009  to  Tue Feb 24 18:24:49.091 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command wait for telescope complete for both LBC

   9  FAILED    IIF        command.stepFocus                                             Tue Feb 24 19:22:48.481 2009  to  Tue Feb 24 19:22:56.000 2009   (  7.52) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  10  FAILED    IIF        command.sendWavefront                                         Tue Feb 24 19:41:15.973 2009  to  Tue Feb 24 19:41:16.610 2009   (  0.64) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for left LBC for M1

  11  FAILED    IIF        command.stepFocus                                             Tue Feb 24 20:13:25.130 2009  to  Tue Feb 24 20:13:36.606 2009   ( 11.48) secs
                    IIF MoveFocus command started for left LBC for 8.300000000000000e-02
                    IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  12  FAILED    IIF        command.sendWavefront                                         Tue Feb 24 20:30:30.525 2009  to  Tue Feb 24 20:30:45.274 2009   ( 14.75) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

  13  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 21:57:52.342 2009  to  Tue Feb 24 22:01:24.049 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

  14  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 22:02:45.524 2009  to  Tue Feb 24 22:02:45.524 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command complete for both LBC mode TRACK from IIF

  15  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 22:30:56.119 2009  to  Tue Feb 24 22:33:50.235 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

  16  SEQERROR  IIF        command.preset.telescopeWait                                  Tue Feb 24 22:32:43.946 2009  to  Tue Feb 24 22:33:59.618 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command wait for telescope started for both LBC
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit

  17  SEQERROR  IIF        command.preset.telescopeWait                                  Tue Feb 24 22:34:27.693 2009  to  Tue Feb 24 22:34:27.693 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command wait for telescope complete for both LBC

  18  FAILED    IIF        command.moveFocus                                             Wed Feb 25 01:19:50.928 2009  to  Wed Feb 25 01:19:51.427 2009   (  0.50) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

  19  FAILED    IIF        command.sendWavefront                                         Wed Feb 25 02:44:12.430 2009  to  Wed Feb 25 02:44:26.601 2009   ( 14.17) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     airCompressor.command.setDeadBandTemperature . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     chiller.command.setNormalFlow. . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4234                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8468                      
                                                                                                   
     lights.command.disable . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     7                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     157                      

ECS Events of Interest

   1  SXDXBOTH  ECS        lights.command.enable                                         Tue Feb 24 18:32:08.780 2009  to  Tue Feb 24 18:32:08.780 2009   (  0.00) secs
                    

   2  SXDXBOTH  ECS        lights.command.disable                                        Wed Feb 25 06:57:04.787 2009  to  Wed Feb 25 06:57:04.787 2009   (  0.00) secs
                    
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         21                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      46                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     322                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     402                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     134                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            16
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             5
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       4                      
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  4           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      12                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:41.374 2009  to  Wed Feb 25 07:02:41.374 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:41.376 2009  to  Wed Feb 25 07:02:41.376 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Feb 25 07:02:41.480 2009  to  Wed Feb 25 07:02:41.480 2009   (  0.00) secs
                    drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:44.174 2009  to  Wed Feb 25 07:02:44.174 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:44.178 2009  to  Wed Feb 25 07:02:44.178 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.509 2009  to  Wed Feb 25 07:02:44.509 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Feb 25 07:02:44.501 2009  to  Wed Feb 25 07:02:44.501 2009   (  0.00) secs
                    AZ bad poly no. 1: BAD Poly:t0 is -1.317222e+00 seconds in the past!

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Feb 25 07:02:44.502 2009  to  Wed Feb 25 07:02:44.502 2009   (  0.00) secs
                    EL bad poly no. 1: BAD Poly:t0 is -1.318205e+00 seconds in the past!
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.14   100.0 %        342        342                      
                                                                       0.01    0.02    0.01    0.14
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.11    0.06    0.21   100.0 %        312        312                      
                                                                       0.03    0.11    0.06    0.21
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.23    0.22    0.01    1.30   100.0 %         49         49                      
                                                                       0.23    0.22    0.01    1.30
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.30    0.25    0.01    1.06   100.0 %         22         22                      
                                                                       0.30    0.25    0.01    1.06
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.33    0.44    0.00    0.84   100.0 %         22         22                      
                                                                       0.14    0.65    0.52    0.84

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       1                      
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           

PCS Events of Interest

   1  FAILED    PCS        telescope.telemetryError                                      Tue Feb 24 18:22:31.454 2009  to  Tue Feb 24 18:22:31.454 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2006: MySQL server has gone away

   2  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 18:22:31.540 2009  to  Tue Feb 24 18:22:35.653 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   3  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 18:22:31.845 2009  to  Tue Feb 24 18:22:31.845 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   4  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 19:20:02.965 2009  to  Tue Feb 24 19:47:55.504 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   5  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 19:20:03.296 2009  to  Tue Feb 24 19:20:03.296 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   6  FAILED    PCS        guider.telemetryError                                         Tue Feb 24 19:21:10.247 2009  to  Tue Feb 24 19:21:10.247 2009   (  0.00) secs
                    PCS Guider telemetry error: 2006: MySQL server has gone away

   7  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:07:44.823 2009  to  Tue Feb 24 21:57:53.104 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:07:45.097 2009  to  Tue Feb 24 21:07:45.097 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:57:53.104 2009  to  Tue Feb 24 22:01:24.802 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:57:53.430 2009  to  Tue Feb 24 21:57:53.430 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:01:24.802 2009  to  Tue Feb 24 22:17:21.217 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:01:25.068 2009  to  Tue Feb 24 22:01:25.068 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:17:21.217 2009  to  Tue Feb 24 22:20:10.737 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:17:21.487 2009  to  Tue Feb 24 22:17:21.487 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:33:51.629 2009  to  Tue Feb 24 23:16:40.560 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:33:51.899 2009  to  Tue Feb 24 22:33:51.899 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate. . . . . . . . . . . . . . . . . . .    0.00    1.05    1.05    1.05   100.0 %          1          1                      
                                                                       0.00    1.05    1.05    1.05
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.01    1.05    1.04    1.06   100.0 %          3          3                      
                                                                       0.01    1.05    1.04    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.64    2.52    2.03    5.06   100.0 %        119        119                      
                                                                       0.64    2.52    2.03    5.06
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    6.42    5.05    0.00   71.16    99.3 %        942        935          7           
                                                                       6.43    5.06    2.02   71.16

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       3                      
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            29
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            91
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      94                      
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  4           
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 32           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 32           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      32                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             6
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             2
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .      34                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .      29                      

PMC Events of Interest

   1  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 18:33:20.503 2009  to  Tue Feb 24 18:33:20.503 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   2  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 18:42:57.872 2009  to  Tue Feb 24 18:42:57.872 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   3  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 18:57:34.851 2009  to  Tue Feb 24 18:57:34.851 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   4  FAILED    PMC        VxInterface.close                                             Tue Feb 24 18:57:34.897 2009  to  Tue Feb 24 18:57:34.897 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:20:29.539 2009  to  Tue Feb 24 19:20:29.539 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:20:29.574 2009  to  Tue Feb 24 19:20:29.574 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:22:48.673 2009  to  Tue Feb 24 19:22:55.708 2009   (  7.04) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:44.134 2009  to  Tue Feb 24 19:32:44.631 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:44.631 2009  to  Tue Feb 24 19:32:44.684 2009   (  0.05) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:46.167 2009  to  Tue Feb 24 19:32:46.167 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  11  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:37:14.125 2009  to  Tue Feb 24 19:37:14.125 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:37:14.152 2009  to  Tue Feb 24 19:37:14.152 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  13  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:40:26.524 2009  to  Tue Feb 24 19:40:26.524 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:40:26.496 2009  to  Tue Feb 24 19:40:26.496 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  15  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:13.032 2009  to  Tue Feb 24 19:41:16.346 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:16.346 2009  to  Tue Feb 24 19:41:16.369 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:18.070 2009  to  Tue Feb 24 19:41:18.070 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  18  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:45:33.173 2009  to  Tue Feb 24 19:45:33.173 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:45:33.149 2009  to  Tue Feb 24 19:45:33.149 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  20  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:52:02.918 2009  to  Tue Feb 24 19:52:02.918 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:52:02.890 2009  to  Tue Feb 24 19:52:02.890 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Tue Feb 24 20:07:17.381 2009  to  Tue Feb 24 20:07:17.381 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  23  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 20:07:17.351 2009  to  Tue Feb 24 20:07:17.351 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 20:13:25.267 2009  to  Tue Feb 24 20:13:36.339 2009   ( 11.07) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 20:16:12.370 2009  to  Tue Feb 24 20:16:12.370 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  26  FAILED    PMC        VxInterface.close                                             Tue Feb 24 20:16:12.421 2009  to  Tue Feb 24 20:16:12.421 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  27  FAILED    PMC        VxInterface.packetReadError                                   Tue Feb 24 20:27:42.026 2009  to  Tue Feb 24 20:27:42.026 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  28  FAILED    PMC        VxInterface.selectTimeout                                     Tue Feb 24 20:27:41.974 2009  to  Tue Feb 24 20:27:41.974 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  29  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 20:27:42.077 2009  to  Tue Feb 24 20:27:42.077 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  30  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 20:30:33.918 2009  to  Tue Feb 24 20:30:44.964 2009   ( 11.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  FAILED    PMC        VxInterface.close                                             Tue Feb 24 21:10:02.408 2009  to  Tue Feb 24 21:10:02.408 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 21:10:02.378 2009  to  Tue Feb 24 21:10:02.378 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Tue Feb 24 21:17:55.634 2009  to  Tue Feb 24 21:17:55.634 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 21:17:55.606 2009  to  Tue Feb 24 21:17:55.606 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 21:43:07.027 2009  to  Tue Feb 24 21:43:07.027 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  36  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:18:14.604 2009  to  Tue Feb 24 22:18:14.604 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:18:14.656 2009  to  Tue Feb 24 22:18:14.656 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:20:15.367 2009  to  Tue Feb 24 22:20:15.367 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:20:15.339 2009  to  Tue Feb 24 22:20:15.339 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  40  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:22:27.046 2009  to  Tue Feb 24 22:22:27.046 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:22:27.019 2009  to  Tue Feb 24 22:22:27.019 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:32:26.902 2009  to  Tue Feb 24 22:32:26.902 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:32:26.873 2009  to  Tue Feb 24 22:32:26.873 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 23:50:03.721 2009  to  Tue Feb 24 23:50:03.721 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Tue Feb 24 23:50:03.750 2009  to  Tue Feb 24 23:50:03.750 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  46  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:07:46.482 2009  to  Wed Feb 25 00:07:46.482 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:07:46.460 2009  to  Wed Feb 25 00:07:46.460 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:24:04.643 2009  to  Wed Feb 25 00:24:04.643 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:24:04.611 2009  to  Wed Feb 25 00:24:04.611 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:30:11.955 2009  to  Wed Feb 25 00:30:11.955 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  51  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:30:11.985 2009  to  Wed Feb 25 00:30:11.985 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:54:47.564 2009  to  Wed Feb 25 00:54:47.564 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:54:47.594 2009  to  Wed Feb 25 00:54:47.594 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:58:03.102 2009  to  Wed Feb 25 00:58:03.102 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  55  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:58:03.155 2009  to  Wed Feb 25 00:58:03.155 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  56  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:02:14.795 2009  to  Wed Feb 25 01:02:14.795 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:02:14.763 2009  to  Wed Feb 25 01:02:14.763 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:02:34.787 2009  to  Wed Feb 25 01:02:34.787 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:02:34.760 2009  to  Wed Feb 25 01:02:34.760 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  60  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:48.043 2009  to  Wed Feb 25 01:19:51.103 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:51.103 2009  to  Wed Feb 25 01:19:51.159 2009   (  0.06) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:54.092 2009  to  Wed Feb 25 01:19:54.092 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  63  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:28:06.692 2009  to  Wed Feb 25 01:28:06.692 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:28:06.659 2009  to  Wed Feb 25 01:28:06.659 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  65  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:36:18.416 2009  to  Wed Feb 25 01:36:18.416 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:36:18.384 2009  to  Wed Feb 25 01:36:18.384 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:50:11.028 2009  to  Wed Feb 25 01:50:11.028 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  68  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:50:11.079 2009  to  Wed Feb 25 01:50:11.079 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  69  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 02:44:16.295 2009  to  Wed Feb 25 02:44:26.365 2009   ( 10.07) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    4.88    4.97    0.27   74.52    99.5 %        573        570          3           
                                                                       4.85    4.95    0.27   74.52
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.08   100.0 %         30         30                      
                                                                       0.01    0.03    0.02    0.08
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    6.35    5.52    0.37   70.47    99.2 %        364        361          3           
                                                                       6.37    5.51    2.21   70.47
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    4.88    5.04    0.33   74.59    99.5 %        573        570          3           
                                                                       4.86    5.02    0.33   74.59
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    5.25    5.00    0.00   74.36    99.3 %        588        584          4           
                                                                       5.24    5.01    0.16   74.36
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    6.42    5.15    0.00   71.25    99.3 %        942        935          7           
                                                                       6.43    5.16    2.10   71.25
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.07    0.04    0.35   100.0 %        195        195                      
                                                                       0.03    0.07    0.04    0.35
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    6.35    5.44    0.29   70.39    99.2 %        364        361          3           
                                                                       6.36    5.43    2.16   70.39
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.05    0.03    0.06   100.0 %         13         13                      
                                                                       0.01    0.05    0.03    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.04    0.02    0.09   100.0 %        586        586                      
                                                                       0.01    0.04    0.02    0.09

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               6990           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:24:56.982 2009  to  Tue Feb 24 18:24:56.982 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.6889315e-04 3.5417080e-04 -4.5442581e-04 -5.5851460e-02 1.5963364e-01 3.6803722e-02

   2  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:28:27.824 2009  to  Tue Feb 24 18:28:27.824 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.9284101e-04 1.2818575e-03 -4.5537949e-04 -6.5039158e-02 1.5658951e-01 3.8438797e-02

   3  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:28:28.056 2009  to  Tue Feb 24 18:28:28.056 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.9284101e-04 1.2818575e-03 -4.5537949e-04 -6.5039158e-02 1.5658951e-01 3.8438797e-02

   4  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:29:09.159 2009  to  Tue Feb 24 18:29:09.159 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.1906922e-03 1.8506050e-03 -1.1436939e-03 -1.0438919e-01 1.6751671e-01 6.6559315e-02

   5  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:29:09.414 2009  to  Tue Feb 24 18:29:09.414 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.1906922e-03 1.8506050e-03 -1.1436939e-03 -1.0438919e-01 1.6751671e-01 6.6559315e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:22.184 2009  to  Tue Feb 24 18:33:22.184 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0767450e-03 -2.2161007e-04 -7.5900555e-04 1.5656567e-01 -5.8914185e-02 -6.9613099e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:22.431 2009  to  Tue Feb 24 18:33:22.431 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0767450e-03 -2.2161007e-04 -7.5900555e-04 1.5656567e-01 -5.8914185e-02 -6.9613099e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:29.358 2009  to  Tue Feb 24 18:33:29.358 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2549629e-03 -5.1462650e-04 -5.7387352e-04 1.7239666e-01 -4.2045593e-02 -5.9126496e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:29.604 2009  to  Tue Feb 24 18:33:29.604 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2549629e-03 -5.1462650e-04 -5.7387352e-04 1.7239666e-01 -4.2045593e-02 -5.9126496e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:27.604 2009  to  Tue Feb 24 18:34:27.604 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:27.855 2009  to  Tue Feb 24 18:34:27.855 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:28.093 2009  to  Tue Feb 24 18:34:28.093 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:45.266 2009  to  Tue Feb 24 19:02:45.266 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:46.536 2009  to  Tue Feb 24 19:02:46.536 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5501976e-03 -2.4129152e-03 -1.5949011e-03 1.6595364e-01 -1.2758255e-02 4.6798229e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:47.161 2009  to  Tue Feb 24 19:02:47.161 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:47.404 2009  to  Tue Feb 24 19:02:47.404 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.415 2009  to  Tue Feb 24 19:02:48.415 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.643 2009  to  Tue Feb 24 19:02:48.643 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.899 2009  to  Tue Feb 24 19:02:48.899 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:49.127 2009  to  Tue Feb 24 19:02:49.127 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:50.802 2009  to  Tue Feb 24 19:02:50.802 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:51.033 2009  to  Tue Feb 24 19:02:51.033 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.097 2009  to  Tue Feb 24 19:02:53.097 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.097 2009  to  Tue Feb 24 19:02:53.097 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.323 2009  to  Tue Feb 24 19:02:53.323 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  26  FAILED    PSF        command.setInstrumentOffsets                                  Tue Feb 24 19:22:48.525 2009  to  Tue Feb 24 19:22:55.863 2009   (  7.34) secs
                    right PSF SetInstrumentOffsets failed

  27  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Feb 24 19:22:48.580 2009  to  Tue Feb 24 19:22:55.807 2009   (  7.23) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  28  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:22:48.627 2009  to  Tue Feb 24 19:22:55.751 2009   (  7.12) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  29  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:43.912 2009  to  Tue Feb 24 19:32:44.398 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  30  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:44.086 2009  to  Tue Feb 24 19:32:44.568 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  31  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:44.398 2009  to  Tue Feb 24 19:32:44.804 2009   (  0.41) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  32  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:44.568 2009  to  Tue Feb 24 19:32:44.747 2009   (  0.18) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:46.232 2009  to  Tue Feb 24 19:32:46.232 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  34  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:46.258 2009  to  Tue Feb 24 19:32:46.258 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  35  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:12.817 2009  to  Tue Feb 24 19:41:16.145 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  36  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:12.994 2009  to  Tue Feb 24 19:41:16.309 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  FAILED    PSF        command.applyZernikes                                         Tue Feb 24 19:41:16.042 2009  to  Tue Feb 24 19:41:16.471 2009   (  0.43) secs
                    left PSF ApplyZernikes failed

  38  FAILED    PSF        command.setZernikes                                           Tue Feb 24 19:41:16.005 2009  to  Tue Feb 24 19:41:16.515 2009   (  0.51) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  39  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:16.145 2009  to  Tue Feb 24 19:41:16.439 2009   (  0.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:16.309 2009  to  Tue Feb 24 19:41:16.407 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  41  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:18.137 2009  to  Tue Feb 24 19:41:18.137 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  42  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:18.192 2009  to  Tue Feb 24 19:41:18.192 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  43  FAILED    PSF        command.setInstrumentOffsets                                  Tue Feb 24 20:13:25.160 2009  to  Tue Feb 24 20:13:36.493 2009   ( 11.33) secs
                    right PSF SetInstrumentOffsets failed

  44  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Feb 24 20:13:25.200 2009  to  Tue Feb 24 20:13:36.435 2009   ( 11.24) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  45  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 20:13:25.226 2009  to  Tue Feb 24 20:13:36.378 2009   ( 11.15) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  46  FAILED    PSF        command.applyZernikes                                         Tue Feb 24 20:30:30.585 2009  to  Tue Feb 24 20:30:45.108 2009   ( 14.52) secs
                    right PSF ApplyZernikes failed

  47  FAILED    PSF        command.setZernikes                                           Tue Feb 24 20:30:30.560 2009  to  Tue Feb 24 20:30:45.164 2009   ( 14.60) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  48  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 20:30:30.726 2009  to  Tue Feb 24 20:30:45.052 2009   ( 14.33) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 20:30:33.885 2009  to  Tue Feb 24 20:30:45.017 2009   ( 11.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  50  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:48.007 2009  to  Wed Feb 25 01:19:51.041 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  51  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 25 01:19:50.960 2009  to  Wed Feb 25 01:19:51.333 2009   (  0.37) secs
                    left PSF SetInstrumentOffsets failed

  52  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 25 01:19:50.989 2009  to  Wed Feb 25 01:19:51.277 2009   (  0.29) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  53  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:51.041 2009  to  Wed Feb 25 01:19:51.222 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:54.157 2009  to  Wed Feb 25 01:19:54.157 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  55  FAILED    PSF        command.setZernikes                                           Wed Feb 25 02:44:12.503 2009  to  Wed Feb 25 02:44:26.527 2009   ( 14.02) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  56  FAILED    PSF        command.applyZernikes                                         Wed Feb 25 02:44:12.535 2009  to  Wed Feb 25 02:44:26.485 2009   ( 13.95) secs
                    right PSF ApplyZernikes failed

  57  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Feb 25 02:44:12.653 2009  to  Wed Feb 25 02:44:26.442 2009   ( 13.79) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 02:44:16.256 2009  to  Wed Feb 25 02:44:26.413 2009   ( 10.16) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PCS        telescope.telemetryError                                      Tue Feb 24 18:22:31.454 2009  to  Tue Feb 24 18:22:31.454 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2006: MySQL server has gone away

   2  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 18:22:31.540 2009  to  Tue Feb 24 18:22:35.653 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   3  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 18:22:31.845 2009  to  Tue Feb 24 18:22:31.845 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   4  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:22:33.009 2009  to  Tue Feb 24 18:23:31.730 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

   5  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:22:33.729 2009  to  Tue Feb 24 18:23:31.925 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command wait for telescope started for both LBC

   6  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:23:31.730 2009  to  Tue Feb 24 18:24:20.150 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

   7  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:23:31.925 2009  to  Tue Feb 24 18:24:20.741 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command wait for telescope started for both LBC

   8  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:24:49.039 2009  to  Tue Feb 24 18:24:49.039 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

   9  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:24:49.024 2009  to  Tue Feb 24 18:24:49.024 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command wait for telescope complete for both LBC

  10  SEQERROR  IIF        command.offset                                                Tue Feb 24 18:24:49.129 2009  to  Tue Feb 24 18:24:49.129 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

  11  SEQERROR  IIF        command.offset.telescopeWait                                  Tue Feb 24 18:24:49.091 2009  to  Tue Feb 24 18:24:49.091 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command wait for telescope complete for both LBC

  12  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:24:56.982 2009  to  Tue Feb 24 18:24:56.982 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.6889315e-04 3.5417080e-04 -4.5442581e-04 -5.5851460e-02 1.5963364e-01 3.6803722e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:28:27.824 2009  to  Tue Feb 24 18:28:27.824 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.9284101e-04 1.2818575e-03 -4.5537949e-04 -6.5039158e-02 1.5658951e-01 3.8438797e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:28:28.056 2009  to  Tue Feb 24 18:28:28.056 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.9284101e-04 1.2818575e-03 -4.5537949e-04 -6.5039158e-02 1.5658951e-01 3.8438797e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:29:09.159 2009  to  Tue Feb 24 18:29:09.159 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.1906922e-03 1.8506050e-03 -1.1436939e-03 -1.0438919e-01 1.6751671e-01 6.6559315e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:29:09.414 2009  to  Tue Feb 24 18:29:09.414 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.1906922e-03 1.8506050e-03 -1.1436939e-03 -1.0438919e-01 1.6751671e-01 6.6559315e-02

  17  SXDXBOTH  ECS        lights.command.enable                                         Tue Feb 24 18:32:08.780 2009  to  Tue Feb 24 18:32:08.780 2009   (  0.00) secs
                    

  18  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 18:33:20.503 2009  to  Tue Feb 24 18:33:20.503 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  19  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:22.184 2009  to  Tue Feb 24 18:33:22.184 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0767450e-03 -2.2161007e-04 -7.5900555e-04 1.5656567e-01 -5.8914185e-02 -6.9613099e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:22.431 2009  to  Tue Feb 24 18:33:22.431 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0767450e-03 -2.2161007e-04 -7.5900555e-04 1.5656567e-01 -5.8914185e-02 -6.9613099e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:29.358 2009  to  Tue Feb 24 18:33:29.358 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2549629e-03 -5.1462650e-04 -5.7387352e-04 1.7239666e-01 -4.2045593e-02 -5.9126496e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:33:29.604 2009  to  Tue Feb 24 18:33:29.604 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2549629e-03 -5.1462650e-04 -5.7387352e-04 1.7239666e-01 -4.2045593e-02 -5.9126496e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:27.604 2009  to  Tue Feb 24 18:34:27.604 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:27.855 2009  to  Tue Feb 24 18:34:27.855 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 18:34:28.093 2009  to  Tue Feb 24 18:34:28.093 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.2067556e-03 9.0003014e-05 -5.7327747e-04 1.6308689e-01 -2.5207520e-02 -5.8557510e-02

  26  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 18:42:57.872 2009  to  Tue Feb 24 18:42:57.872 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  27  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 18:57:34.851 2009  to  Tue Feb 24 18:57:34.851 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  28  FAILED    PMC        VxInterface.close                                             Tue Feb 24 18:57:34.897 2009  to  Tue Feb 24 18:57:34.897 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  29  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:45.266 2009  to  Tue Feb 24 19:02:45.266 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:46.536 2009  to  Tue Feb 24 19:02:46.536 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5501976e-03 -2.4129152e-03 -1.5949011e-03 1.6595364e-01 -1.2758255e-02 4.6798229e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:47.161 2009  to  Tue Feb 24 19:02:47.161 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:47.404 2009  to  Tue Feb 24 19:02:47.404 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.415 2009  to  Tue Feb 24 19:02:48.415 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.643 2009  to  Tue Feb 24 19:02:48.643 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:48.899 2009  to  Tue Feb 24 19:02:48.899 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:49.127 2009  to  Tue Feb 24 19:02:49.127 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.3735294e-03 -2.1090508e-03 -1.9741058e-03 1.5008259e-01 4.8389435e-03 6.8279266e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:50.802 2009  to  Tue Feb 24 19:02:50.802 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:51.033 2009  to  Tue Feb 24 19:02:51.033 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.097 2009  to  Tue Feb 24 19:02:53.097 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.097 2009  to  Tue Feb 24 19:02:53.097 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.8624663e-03 -6.0427189e-04 1.8811226e-04 -6.2199116e-02 1.6505814e-01 2.4728775e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Tue Feb 24 19:02:53.323 2009  to  Tue Feb 24 19:02:53.323 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7284155e-03 -2.1198988e-03 -1.7799139e-03 1.5012646e-01 -2.9615402e-02 3.6315441e-02

  42  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 19:20:02.965 2009  to  Tue Feb 24 19:47:55.504 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  43  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 19:20:03.296 2009  to  Tue Feb 24 19:20:03.296 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  44  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:20:29.539 2009  to  Tue Feb 24 19:20:29.539 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:20:29.574 2009  to  Tue Feb 24 19:20:29.574 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  46  FAILED    PCS        guider.telemetryError                                         Tue Feb 24 19:21:10.247 2009  to  Tue Feb 24 19:21:10.247 2009   (  0.00) secs
                    PCS Guider telemetry error: 2006: MySQL server has gone away

  47  FAILED    IIF        command.stepFocus                                             Tue Feb 24 19:22:48.481 2009  to  Tue Feb 24 19:22:56.000 2009   (  7.52) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  48  FAILED    PSF        command.setInstrumentOffsets                                  Tue Feb 24 19:22:48.525 2009  to  Tue Feb 24 19:22:55.863 2009   (  7.34) secs
                    right PSF SetInstrumentOffsets failed

  49  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Feb 24 19:22:48.580 2009  to  Tue Feb 24 19:22:55.807 2009   (  7.23) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:22:48.673 2009  to  Tue Feb 24 19:22:55.708 2009   (  7.04) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:22:48.627 2009  to  Tue Feb 24 19:22:55.751 2009   (  7.12) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:43.912 2009  to  Tue Feb 24 19:32:44.398 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  53  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:44.134 2009  to  Tue Feb 24 19:32:44.631 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:44.086 2009  to  Tue Feb 24 19:32:44.568 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:44.398 2009  to  Tue Feb 24 19:32:44.804 2009   (  0.41) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:44.568 2009  to  Tue Feb 24 19:32:44.747 2009   (  0.18) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:44.631 2009  to  Tue Feb 24 19:32:44.684 2009   (  0.05) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  58  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:32:46.167 2009  to  Tue Feb 24 19:32:46.167 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  59  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:32:46.232 2009  to  Tue Feb 24 19:32:46.232 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  60  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:32:46.258 2009  to  Tue Feb 24 19:32:46.258 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  61  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:37:14.125 2009  to  Tue Feb 24 19:37:14.125 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  62  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:37:14.152 2009  to  Tue Feb 24 19:37:14.152 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  63  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:40:26.524 2009  to  Tue Feb 24 19:40:26.524 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:40:26.496 2009  to  Tue Feb 24 19:40:26.496 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  65  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:12.817 2009  to  Tue Feb 24 19:41:16.145 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:13.032 2009  to  Tue Feb 24 19:41:16.346 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:12.994 2009  to  Tue Feb 24 19:41:16.309 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  FAILED    IIF        command.sendWavefront                                         Tue Feb 24 19:41:15.973 2009  to  Tue Feb 24 19:41:16.610 2009   (  0.64) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for left LBC for M1

  69  FAILED    PSF        command.applyZernikes                                         Tue Feb 24 19:41:16.042 2009  to  Tue Feb 24 19:41:16.471 2009   (  0.43) secs
                    left PSF ApplyZernikes failed

  70  FAILED    PSF        command.setZernikes                                           Tue Feb 24 19:41:16.005 2009  to  Tue Feb 24 19:41:16.515 2009   (  0.51) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  71  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:16.145 2009  to  Tue Feb 24 19:41:16.439 2009   (  0.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  72  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:16.309 2009  to  Tue Feb 24 19:41:16.407 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  73  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:16.346 2009  to  Tue Feb 24 19:41:16.369 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  74  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 19:41:18.070 2009  to  Tue Feb 24 19:41:18.070 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  75  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 19:41:18.137 2009  to  Tue Feb 24 19:41:18.137 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  76  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 19:41:18.192 2009  to  Tue Feb 24 19:41:18.192 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  77  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:45:33.173 2009  to  Tue Feb 24 19:45:33.173 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:45:33.149 2009  to  Tue Feb 24 19:45:33.149 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  79  FAILED    PMC        VxInterface.close                                             Tue Feb 24 19:52:02.918 2009  to  Tue Feb 24 19:52:02.918 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  80  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 19:52:02.890 2009  to  Tue Feb 24 19:52:02.890 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  81  FAILED    PMC        VxInterface.close                                             Tue Feb 24 20:07:17.381 2009  to  Tue Feb 24 20:07:17.381 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 20:07:17.351 2009  to  Tue Feb 24 20:07:17.351 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  83  FAILED    PSF        command.setInstrumentOffsets                                  Tue Feb 24 20:13:25.160 2009  to  Tue Feb 24 20:13:36.493 2009   ( 11.33) secs
                    right PSF SetInstrumentOffsets failed

  84  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Feb 24 20:13:25.200 2009  to  Tue Feb 24 20:13:36.435 2009   ( 11.24) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  85  FAILED    IIF        command.stepFocus                                             Tue Feb 24 20:13:25.130 2009  to  Tue Feb 24 20:13:36.606 2009   ( 11.48) secs
                    IIF MoveFocus command started for left LBC for 8.300000000000000e-02
                    IIF StepFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF StepFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF StepFocus command failed for right LBC for 0.000000000000000e+00

  86  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 20:13:25.267 2009  to  Tue Feb 24 20:13:36.339 2009   ( 11.07) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 20:13:25.226 2009  to  Tue Feb 24 20:13:36.378 2009   ( 11.15) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  88  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 20:16:12.370 2009  to  Tue Feb 24 20:16:12.370 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  89  FAILED    PMC        VxInterface.close                                             Tue Feb 24 20:16:12.421 2009  to  Tue Feb 24 20:16:12.421 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  90  FAILED    PMC        VxInterface.packetReadError                                   Tue Feb 24 20:27:42.026 2009  to  Tue Feb 24 20:27:42.026 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  91  FAILED    PMC        VxInterface.selectTimeout                                     Tue Feb 24 20:27:41.974 2009  to  Tue Feb 24 20:27:41.974 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  92  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 20:27:42.077 2009  to  Tue Feb 24 20:27:42.077 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  93  FAILED    PSF        command.applyZernikes                                         Tue Feb 24 20:30:30.585 2009  to  Tue Feb 24 20:30:45.108 2009   ( 14.52) secs
                    right PSF ApplyZernikes failed

  94  FAILED    PSF        command.setZernikes                                           Tue Feb 24 20:30:30.560 2009  to  Tue Feb 24 20:30:45.164 2009   ( 14.60) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  95  FAILED    IIF        command.sendWavefront                                         Tue Feb 24 20:30:30.525 2009  to  Tue Feb 24 20:30:45.274 2009   ( 14.75) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

  96  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Feb 24 20:30:30.726 2009  to  Tue Feb 24 20:30:45.052 2009   ( 14.33) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Feb 24 20:30:33.918 2009  to  Tue Feb 24 20:30:44.964 2009   ( 11.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  98  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Feb 24 20:30:33.885 2009  to  Tue Feb 24 20:30:45.017 2009   ( 11.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  99  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:07:44.823 2009  to  Tue Feb 24 21:57:53.104 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 100  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:07:45.097 2009  to  Tue Feb 24 21:07:45.097 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 101  FAILED    PMC        VxInterface.close                                             Tue Feb 24 21:10:02.408 2009  to  Tue Feb 24 21:10:02.408 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 21:10:02.378 2009  to  Tue Feb 24 21:10:02.378 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 103  FAILED    PMC        VxInterface.close                                             Tue Feb 24 21:17:55.634 2009  to  Tue Feb 24 21:17:55.634 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 104  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 21:17:55.606 2009  to  Tue Feb 24 21:17:55.606 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 105  FAILED    PMC        thermal.badReceive                                            Tue Feb 24 21:43:07.027 2009  to  Tue Feb 24 21:43:07.027 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 106  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 21:57:52.342 2009  to  Tue Feb 24 22:01:24.049 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

 107  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:57:53.104 2009  to  Tue Feb 24 22:01:24.802 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 108  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 21:57:53.430 2009  to  Tue Feb 24 21:57:53.430 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 109  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:01:24.802 2009  to  Tue Feb 24 22:17:21.217 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 110  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:01:25.068 2009  to  Tue Feb 24 22:01:25.068 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 111  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 22:02:45.524 2009  to  Tue Feb 24 22:02:45.524 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command complete for both LBC mode TRACK from IIF

 112  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:17:21.217 2009  to  Tue Feb 24 22:20:10.737 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 113  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:17:21.487 2009  to  Tue Feb 24 22:17:21.487 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 114  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:18:14.604 2009  to  Tue Feb 24 22:18:14.604 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 115  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:18:14.656 2009  to  Tue Feb 24 22:18:14.656 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 116  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:20:15.367 2009  to  Tue Feb 24 22:20:15.367 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 117  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:20:15.339 2009  to  Tue Feb 24 22:20:15.339 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 118  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:22:27.046 2009  to  Tue Feb 24 22:22:27.046 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 119  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:22:27.019 2009  to  Tue Feb 24 22:22:27.019 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 120  SEQERROR  IIF        command.preset.(TRACK)                                        Tue Feb 24 22:30:56.119 2009  to  Tue Feb 24 22:33:50.235 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

 121  FAILED    PMC        VxInterface.close                                             Tue Feb 24 22:32:26.902 2009  to  Tue Feb 24 22:32:26.902 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 122  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 22:32:26.873 2009  to  Tue Feb 24 22:32:26.873 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 123  SEQERROR  IIF        command.preset.telescopeWait                                  Tue Feb 24 22:32:43.946 2009  to  Tue Feb 24 22:33:59.618 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command wait for telescope started for both LBC
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit

 124  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:33:51.629 2009  to  Tue Feb 24 23:16:40.560 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 125  SEQERROR  PCS        telescope.command.startTracking                               Tue Feb 24 22:33:51.899 2009  to  Tue Feb 24 22:33:51.899 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 126  SEQERROR  IIF        command.preset.telescopeWait                                  Tue Feb 24 22:34:27.693 2009  to  Tue Feb 24 22:34:27.693 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command wait for telescope complete for both LBC

 127  FAILED    PMC        VxInterface.lengthError                                       Tue Feb 24 23:50:03.721 2009  to  Tue Feb 24 23:50:03.721 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 128  FAILED    PMC        VxInterface.close                                             Tue Feb 24 23:50:03.750 2009  to  Tue Feb 24 23:50:03.750 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 129  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:07:46.482 2009  to  Wed Feb 25 00:07:46.482 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 130  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:07:46.460 2009  to  Wed Feb 25 00:07:46.460 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 131  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:24:04.643 2009  to  Wed Feb 25 00:24:04.643 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 132  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:24:04.611 2009  to  Wed Feb 25 00:24:04.611 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 133  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:30:11.955 2009  to  Wed Feb 25 00:30:11.955 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 134  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:30:11.985 2009  to  Wed Feb 25 00:30:11.985 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 135  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:54:47.564 2009  to  Wed Feb 25 00:54:47.564 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 136  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:54:47.594 2009  to  Wed Feb 25 00:54:47.594 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 137  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 00:58:03.102 2009  to  Wed Feb 25 00:58:03.102 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 138  FAILED    PMC        VxInterface.close                                             Wed Feb 25 00:58:03.155 2009  to  Wed Feb 25 00:58:03.155 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 139  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:02:14.795 2009  to  Wed Feb 25 01:02:14.795 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 140  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:02:14.763 2009  to  Wed Feb 25 01:02:14.763 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 141  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:02:34.787 2009  to  Wed Feb 25 01:02:34.787 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 142  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:02:34.760 2009  to  Wed Feb 25 01:02:34.760 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 143  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:48.007 2009  to  Wed Feb 25 01:19:51.041 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 144  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:48.043 2009  to  Wed Feb 25 01:19:51.103 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 145  FAILED    IIF        command.moveFocus                                             Wed Feb 25 01:19:50.928 2009  to  Wed Feb 25 01:19:51.427 2009   (  0.50) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

 146  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 25 01:19:50.960 2009  to  Wed Feb 25 01:19:51.333 2009   (  0.37) secs
                    left PSF SetInstrumentOffsets failed

 147  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 25 01:19:50.989 2009  to  Wed Feb 25 01:19:51.277 2009   (  0.29) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 148  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:51.103 2009  to  Wed Feb 25 01:19:51.159 2009   (  0.06) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 149  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:51.041 2009  to  Wed Feb 25 01:19:51.222 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 150  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 01:19:54.092 2009  to  Wed Feb 25 01:19:54.092 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 151  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 01:19:54.157 2009  to  Wed Feb 25 01:19:54.157 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 152  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:28:06.692 2009  to  Wed Feb 25 01:28:06.692 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

 153  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:28:06.659 2009  to  Wed Feb 25 01:28:06.659 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

 154  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:36:18.416 2009  to  Wed Feb 25 01:36:18.416 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 155  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:36:18.384 2009  to  Wed Feb 25 01:36:18.384 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 156  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 25 01:50:11.028 2009  to  Wed Feb 25 01:50:11.028 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 157  FAILED    PMC        VxInterface.close                                             Wed Feb 25 01:50:11.079 2009  to  Wed Feb 25 01:50:11.079 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 158  FAILED    IIF        command.sendWavefront                                         Wed Feb 25 02:44:12.430 2009  to  Wed Feb 25 02:44:26.601 2009   ( 14.17) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 159  FAILED    PSF        command.setZernikes                                           Wed Feb 25 02:44:12.503 2009  to  Wed Feb 25 02:44:26.527 2009   ( 14.02) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 160  FAILED    PSF        command.applyZernikes                                         Wed Feb 25 02:44:12.535 2009  to  Wed Feb 25 02:44:26.485 2009   ( 13.95) secs
                    right PSF ApplyZernikes failed

 161  FAILED    PSF        primaryMirror.command.adjustMirror                            Wed Feb 25 02:44:12.653 2009  to  Wed Feb 25 02:44:26.442 2009   ( 13.79) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 162  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 25 02:44:16.295 2009  to  Wed Feb 25 02:44:26.365 2009   ( 10.07) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 163  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 25 02:44:16.256 2009  to  Wed Feb 25 02:44:26.413 2009   ( 10.16) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 164  SXDXBOTH  ECS        lights.command.disable                                        Wed Feb 25 06:57:04.787 2009  to  Wed Feb 25 06:57:04.787 2009   (  0.00) secs
                    

 165  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:41.374 2009  to  Wed Feb 25 07:02:41.374 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 166  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:41.376 2009  to  Wed Feb 25 07:02:41.376 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 167  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Wed Feb 25 07:02:41.480 2009  to  Wed Feb 25 07:02:41.480 2009   (  0.00) secs
                    drive cabinet has turned on.

 168  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:44.174 2009  to  Wed Feb 25 07:02:44.174 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 169  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Wed Feb 25 07:02:44.178 2009  to  Wed Feb 25 07:02:44.178 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 170  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 171  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 172  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 173  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.507 2009  to  Wed Feb 25 07:02:44.507 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 174  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 175  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 176  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.508 2009  to  Wed Feb 25 07:02:44.508 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 177  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Wed Feb 25 07:02:44.509 2009  to  Wed Feb 25 07:02:44.509 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 178  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Feb 25 07:02:44.501 2009  to  Wed Feb 25 07:02:44.501 2009   (  0.00) secs
                    AZ bad poly no. 1: BAD Poly:t0 is -1.317222e+00 seconds in the past!

 179  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Wed Feb 25 07:02:44.502 2009  to  Wed Feb 25 07:02:44.502 2009   (  0.00) secs
                    EL bad poly no. 1: BAD Poly:t0 is -1.318205e+00 seconds in the past!

**********************************************************