You are here: Foswiki>Software Web>TCSSWReportFile_090221 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Feb 21 2009 to Feb 22 2009
 
    Reporting period beginning:   Sat Feb 21 17:40:02.536 2009
    Reporting period ending:      Sun Feb 22 07:24:53.534 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.08   100.0 %        167        167                      
                                                                       0.01    0.02    0.01    0.08
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.20    0.32    0.13    0.92   100.0 %        542        542                      
                                                                       0.20    0.32    0.13    0.92
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.07    0.05    0.22   100.0 %        694        694                      
                                                                       0.03    0.07    0.05    0.22
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    8.13    5.90    0.42  122.60    99.1 %        542        537          5           
                                                                       6.41    5.71    2.21  110.55
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.42    4.92    1.85    9.59   100.0 %        114        114                      
                                                                       1.42    4.92    1.85    9.59
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.43    4.38    1.42    9.03   100.0 %        114        114                      
                                                                       1.43    4.38    1.42    9.03
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   13.71    8.84    1.01   47.11   100.0 %         18         18                      
                                                                      13.71    8.84    1.01   47.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .    0.01    2.04    2.03    2.07   100.0 %         18         18                      
                                                                       0.01    2.04    2.03    2.07
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   24.50   20.33    7.42   96.60    94.4 %         18         17                     1
                                                                      24.50   20.33    7.42   96.60
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    3.12    4.31    0.38   29.25    99.7 %        988        985          3           
                                                                       3.12    4.31    0.38   29.25
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.63    4.35    2.20    7.28   100.0 %        136        136                      
                                                                       1.63    4.35    2.20    7.28

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            12

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Sat Feb 21 18:28:28.759 2009  to  Sat Feb 21 18:28:35.062 2009   (  6.30) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488406144675926e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

   2  FAILED    IIF        command.moveFocus                                             Sat Feb 21 19:42:44.043 2009  to  Sat Feb 21 19:42:44.463 2009   (  0.42) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

   3  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 21:04:59.509 2009  to  Sat Feb 21 21:05:03.636 2009   (  4.13) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for right LBC for M1

   4  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 21:05:06.350 2009  to  Sat Feb 21 21:05:10.214 2009   (  3.86) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for left LBC for M1

   5  FAILED    IIF        command.moveFocus                                             Sat Feb 21 21:05:15.444 2009  to  Sat Feb 21 21:05:16.023 2009   (  0.58) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Sat Feb 21 21:05:15.464 2009  to  Sat Feb 21 21:05:16.039 2009   (  0.57) secs
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   7  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 22:51:44.834 2009  to  Sat Feb 21 22:51:55.288 2009   ( 10.45) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

   8  FAILED    IIF        command.moveFocus                                             Sun Feb 22 01:50:33.364 2009  to  Sun Feb 22 01:52:35.965 2009   (122.60) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     domeCooling.modulatingValve.command.setModulatingValvePosition                                   100.0 %                     1                      
                                                                                                   
     domeCooling.modulatingValve.command.setState . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4258                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8516                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      45                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         24                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      10                      
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      11                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             5
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            10
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            27
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.hbsAlarm . . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      40                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     553                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     834                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     278                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.BrakeFailSet . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.BrakeSetRelFail. . . . . . . . . . . . . . . . .                  1           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat Feb 21 17:42:38.060 2009  to  Sat Feb 21 17:42:38.060 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

   2  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Sat Feb 21 18:19:43.090 2009  to  Sat Feb 21 18:19:43.090 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Sun Feb 22 05:32:18.628 2009  to  Sun Feb 22 05:32:18.628 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Sun Feb 22 05:32:20.629 2009  to  Sun Feb 22 05:32:20.629 2009   (  0.00) secs
                    Cannot set all brakes or release all brakes.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.01    0.01    0.06   100.0 %        694        694                      
                                                                       0.01    0.01    0.01    0.06
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.11    0.06    0.22   100.0 %        542        542                      
                                                                       0.03    0.11    0.06    0.22
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.15    0.15    0.01    0.70   100.0 %        114        114                      
                                                                       0.15    0.15    0.01    0.70
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.15    0.20    0.01    0.54   100.0 %         25         25                      
                                                                       0.15    0.20    0.01    0.54
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.35    0.34    0.00    0.79    96.0 %         25         24          1           
                                                                       0.13    0.65    0.52    0.79

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           

PCS Events of Interest

   1  FAILED    PCS        telescope.telemetryError                                      Sat Feb 21 18:19:25.085 2009  to  Sat Feb 21 18:19:25.085 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   2  FAILED    PCS        telescope.command.startTracking                               Sat Feb 21 18:19:25.125 2009  to  Sat Feb 21 18:19:25.898 2009   (  0.77) secs
                    PCS will start tracking target
                    PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

   3  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 19:20:20.956 2009  to  Sat Feb 21 19:36:28.262 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 19:20:21.225 2009  to  Sat Feb 21 19:20:21.225 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  FAILED    PCS        guider.telemetryError                                         Sat Feb 21 19:37:40.569 2009  to  Sat Feb 21 19:37:40.569 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

   6  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 20:45:40.631 2009  to  Sat Feb 21 20:51:15.594 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   7  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 20:45:40.898 2009  to  Sat Feb 21 20:45:40.898 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   8  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:03:58.547 2009  to  Sat Feb 21 21:11:41.478 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   9  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:03:58.814 2009  to  Sat Feb 21 21:03:58.814 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  10  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:11:41.478 2009  to  Sat Feb 21 21:39:16.596 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  11  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:11:41.745 2009  to  Sat Feb 21 21:11:41.745 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  12  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:39:16.596 2009  to  Sat Feb 21 21:53:58.411 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  13  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:39:16.865 2009  to  Sat Feb 21 21:39:16.865 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  14  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:53:58.411 2009  to  Sat Feb 21 22:52:24.381 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  15  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:53:58.680 2009  to  Sat Feb 21 21:53:58.680 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  16  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 22:52:24.381 2009  to  Sat Feb 21 23:48:48.753 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  17  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 22:52:24.648 2009  to  Sat Feb 21 22:52:24.648 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  18  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 23:48:48.753 2009  to  Sun Feb 22 00:39:42.222 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  19  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 23:48:49.020 2009  to  Sat Feb 21 23:48:49.020 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  20  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 00:39:42.222 2009  to  Sun Feb 22 00:47:30.816 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  21  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 00:39:42.489 2009  to  Sun Feb 22 00:39:42.489 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  22  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 01:17:17.272 2009  to  Sun Feb 22 01:50:16.137 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  23  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 01:17:17.539 2009  to  Sun Feb 22 01:17:17.539 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  24  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 02:55:22.354 2009  to  Sun Feb 22 03:27:34.874 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  25  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 02:55:22.625 2009  to  Sun Feb 22 02:55:22.625 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  26  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 03:27:34.874 2009  to  Sun Feb 22 03:52:20.261 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  27  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 03:27:35.141 2009  to  Sun Feb 22 03:27:35.141 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.02    1.02    1.02   100.0 %          1          1                      
                                                                       0.00    1.02    1.02    1.02
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.60    2.44    2.02    4.05   100.0 %        166        166                      
                                                                       0.60    2.44    2.02    4.05
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    4.95   11.55    8.05   15.04   100.0 %          2          2                      
                                                                       4.95   11.55    8.05   15.04
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.02    2.02    2.02   100.0 %          2          2                      
                                                                       0.00    2.02    2.02    2.02
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .    5.63    4.65    0.00  122.27    99.1 %       1608       1594         14           
                                                                       4.82    4.62    1.89  110.23

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 35           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 35           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      35                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            60
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     122                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           362
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             3
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             1

PMC Events of Interest

   1  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 18:08:06.737 2009  to  Sat Feb 21 18:08:06.737 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:21:29.278 2009  to  Sat Feb 21 18:21:34.303 2009   (  5.02) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:21:35.040 2009  to  Sat Feb 21 18:21:37.061 2009   (  2.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PMC        VxInterface.close                                             Sat Feb 21 18:22:17.603 2009  to  Sat Feb 21 18:22:17.603 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   5  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 18:22:17.585 2009  to  Sat Feb 21 18:22:17.585 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:28:28.879 2009  to  Sat Feb 21 18:28:34.927 2009   (  6.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        VxInterface.close                                             Sat Feb 21 18:48:50.465 2009  to  Sat Feb 21 18:48:50.465 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 18:48:50.445 2009  to  Sat Feb 21 18:48:50.445 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

   9  FAILED    PMC        VxInterface.close                                             Sat Feb 21 19:25:46.445 2009  to  Sat Feb 21 19:25:46.445 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 19:25:46.423 2009  to  Sat Feb 21 19:25:46.423 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:43.267 2009  to  Sat Feb 21 19:42:44.231 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:44.231 2009  to  Sat Feb 21 19:42:44.266 2009   (  0.04) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  13  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:47.290 2009  to  Sat Feb 21 19:42:47.290 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  14  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:30.697 2009  to  Sat Feb 21 19:44:34.076 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:34.076 2009  to  Sat Feb 21 19:44:34.097 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:36.725 2009  to  Sat Feb 21 19:44:36.725 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  17  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 19:54:16.251 2009  to  Sat Feb 21 19:54:16.251 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Sat Feb 21 19:54:16.268 2009  to  Sat Feb 21 19:54:16.268 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.close                                             Sat Feb 21 20:12:17.019 2009  to  Sat Feb 21 20:12:17.019 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 20:12:17.003 2009  to  Sat Feb 21 20:12:17.003 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  21  FAILED    PMC        VxInterface.close                                             Sat Feb 21 20:14:35.996 2009  to  Sat Feb 21 20:14:35.996 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 20:14:35.981 2009  to  Sat Feb 21 20:14:35.981 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  23  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 20:34:29.354 2009  to  Sat Feb 21 20:34:29.486 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

  24  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 20:34:31.510 2009  to  Sat Feb 21 20:34:31.510 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  25  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:04:46.026 2009  to  Sat Feb 21 21:05:10.014 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:04:46.046 2009  to  Sat Feb 21 21:05:03.356 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:03.356 2009  to  Sat Feb 21 21:05:03.372 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  28  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:10.014 2009  to  Sat Feb 21 21:05:10.036 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  29  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:15.647 2009  to  Sat Feb 21 21:05:15.699 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  30  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:15.678 2009  to  Sat Feb 21 21:05:15.730 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  31  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:27.158 2009  to  Sat Feb 21 21:05:27.158 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  32  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:32.152 2009  to  Sat Feb 21 21:05:32.152 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  33  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 21:38:44.051 2009  to  Sat Feb 21 21:38:44.051 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  34  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:02:21.212 2009  to  Sat Feb 21 22:02:21.212 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:02:21.193 2009  to  Sat Feb 21 22:02:21.193 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  36  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:02:39.722 2009  to  Sat Feb 21 22:02:39.722 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  37  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:02:39.690 2009  to  Sat Feb 21 22:02:39.690 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  38  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 22:05:59.777 2009  to  Sat Feb 21 22:06:05.809 2009   (  6.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 22:51:48.034 2009  to  Sat Feb 21 22:51:55.066 2009   (  7.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  40  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:54:10.640 2009  to  Sat Feb 21 22:54:10.640 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:54:10.625 2009  to  Sat Feb 21 22:54:10.625 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:08:04.126 2009  to  Sat Feb 21 23:08:04.126 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:08:04.103 2009  to  Sat Feb 21 23:08:04.103 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:16:13.445 2009  to  Sat Feb 21 23:16:13.445 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:16:13.428 2009  to  Sat Feb 21 23:16:13.428 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  46  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:19:28.324 2009  to  Sat Feb 21 23:19:28.324 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:19:28.299 2009  to  Sat Feb 21 23:19:28.299 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

  48  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:23:33.181 2009  to  Sat Feb 21 23:23:33.181 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:23:33.160 2009  to  Sat Feb 21 23:23:33.160 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:28:11.058 2009  to  Sat Feb 21 23:28:11.058 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:28:11.019 2009  to  Sat Feb 21 23:28:11.019 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  52  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:34:35.960 2009  to  Sat Feb 21 23:34:35.960 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:34:35.982 2009  to  Sat Feb 21 23:34:35.982 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:37:01.756 2009  to  Sat Feb 21 23:37:01.756 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:37:01.739 2009  to  Sat Feb 21 23:37:01.739 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:52:49.312 2009  to  Sat Feb 21 23:52:49.312 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:52:49.295 2009  to  Sat Feb 21 23:52:49.295 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:01:36.533 2009  to  Sun Feb 22 00:01:36.533 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:01:36.515 2009  to  Sun Feb 22 00:01:36.515 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:20:02.467 2009  to  Sun Feb 22 00:20:02.467 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:20:02.449 2009  to  Sun Feb 22 00:20:02.449 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

  62  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:55:01.650 2009  to  Sun Feb 22 00:55:01.650 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  63  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:55:01.632 2009  to  Sun Feb 22 00:55:01.632 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:26:49.865 2009  to  Sun Feb 22 01:26:49.865 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  65  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:26:49.846 2009  to  Sun Feb 22 01:26:49.846 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:06.426 2009  to  Sun Feb 22 01:32:09.865 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:09.865 2009  to  Sun Feb 22 01:32:09.882 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:12.505 2009  to  Sun Feb 22 01:32:12.505 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  69  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:36:45.670 2009  to  Sun Feb 22 01:36:45.670 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:36:45.655 2009  to  Sun Feb 22 01:36:45.655 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:50:33.529 2009  to  Sun Feb 22 01:52:35.804 2009   (122.27) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  72  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:55:23.287 2009  to  Sun Feb 22 01:55:23.287 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

  73  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:55:23.305 2009  to  Sun Feb 22 01:55:23.305 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

  74  FAILED    PMC        VxInterface.close                                             Sun Feb 22 02:06:08.608 2009  to  Sun Feb 22 02:06:08.608 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  75  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 02:06:08.589 2009  to  Sun Feb 22 02:06:08.589 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  76  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 02:14:59.709 2009  to  Sun Feb 22 02:14:59.709 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Sun Feb 22 02:14:59.733 2009  to  Sun Feb 22 02:14:59.733 2009   (  0.00) secs
                    left PMC Actuator closing network connection
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.12    4.17    0.24   29.08    99.7 %        988        985          3           
                                                                       3.12    4.16    0.24   29.08
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.05   100.0 %         36         36                      
                                                                       0.01    0.03    0.02    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    7.33    5.50    0.31  122.51    99.3 %        678        673          5           
                                                                       5.80    5.35    2.15  110.48
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.12    4.23    0.32   29.16    99.7 %        988        985          3           
                                                                       3.12    4.23    0.32   29.16
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    3.10    4.04    0.15   28.93    99.3 %       1014       1007          7           
                                                                       3.10    4.04    0.15   28.93
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    5.63    4.74    0.00  122.37    99.1 %       1608       1594         14           
                                                                       4.82    4.71    1.95  110.32
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.09    2.09    2.09   100.0 %          2          2                      
                                                                       0.00    2.09    2.09    2.09
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    4.91   11.66    8.18   15.13   100.0 %          2          2                      
                                                                       4.91   11.66    8.18   15.13
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.07    0.04    0.23   100.0 %        277        277                      
                                                                       0.03    0.07    0.04    0.23
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    2.79   15.38   13.41   17.35     0.0 %          2                     2           
                                                                                                   
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    7.33    5.43    0.24  122.45    99.3 %        678        673          5           
                                                                       5.79    5.28    2.11  110.40
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.04    0.03    0.10   100.0 %         31         31                      
                                                                       0.01    0.04    0.03    0.10
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.03    0.01    0.11   100.0 %       1019       1019                      
                                                                       0.01    0.03    0.01    0.11

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1381           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Sat Feb 21 18:21:19.802 2009  to  Sat Feb 21 18:21:37.147 2009   ( 17.35) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PSF        primaryMirror.command.revert                                  Sat Feb 21 18:21:20.975 2009  to  Sat Feb 21 18:21:34.382 2009   ( 13.41) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:21:29.236 2009  to  Sat Feb 21 18:21:34.342 2009   (  5.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:21:34.994 2009  to  Sat Feb 21 18:21:37.094 2009   (  2.10) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.357 2009  to  Sat Feb 21 18:22:00.357 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.8136144e-02 3.3091724e-02 2.1480560e-02 2.0082397e+00 -4.6879959e+00 2.3941755e+00

   6  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.611 2009  to  Sat Feb 21 18:22:00.611 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.8136144e-02 3.3091724e-02 2.1480560e-02 2.0082397e+00 -4.6879959e+00 2.3941755e+00

   7  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.846 2009  to  Sat Feb 21 18:22:00.846 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9403350e-01 3.4749380e-01 2.1042252e-01 1.4687139e+01 -3.6814201e+01 1.7877968e+01

   8  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.085 2009  to  Sat Feb 21 18:22:01.085 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9403350e-01 3.4749380e-01 2.1042252e-01 1.4687139e+01 -3.6814201e+01 1.7877968e+01

   9  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.326 2009  to  Sat Feb 21 18:22:01.326 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1976960e-01 3.9353898e-01 2.3863578e-01 1.3689726e+01 -3.6829163e+01 1.7642935e+01

  10  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.580 2009  to  Sat Feb 21 18:22:01.580 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1976960e-01 3.9353898e-01 2.3863578e-01 1.3689726e+01 -3.6829163e+01 1.7642935e+01

  11  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.814 2009  to  Sat Feb 21 18:22:01.814 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.3541665e-01 4.2211184e-01 2.5736690e-01 9.8381310e+00 -3.1320988e+01 1.4708978e+01

  12  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.050 2009  to  Sat Feb 21 18:22:02.050 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.3541665e-01 4.2211184e-01 2.5736690e-01 9.8381310e+00 -3.1320988e+01 1.4708978e+01

  13  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.291 2009  to  Sat Feb 21 18:22:02.291 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.4095747e-01 2.6006138e-01 1.6049206e-01 5.6386366e+00 -1.9116007e+01 9.0897980e+00

  14  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.546 2009  to  Sat Feb 21 18:22:02.546 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.4095747e-01 2.6006138e-01 1.6049206e-01 5.6386366e+00 -1.9116007e+01 9.0897980e+00

  15  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:03.804 2009  to  Sat Feb 21 18:22:03.804 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.7072897e-03 6.1150193e-03 5.5651665e-03 3.7769318e-02 -4.9409485e-01 3.1308916e-01

  16  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.041 2009  to  Sat Feb 21 18:22:04.041 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.7072897e-03 6.1150193e-03 5.5651665e-03 3.7769318e-02 -4.9409485e-01 3.1308916e-01

  17  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.278 2009  to  Sat Feb 21 18:22:04.278 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4422359e-04 1.0945797e-03 1.1925697e-03 -1.6384506e-01 -5.9925079e-02 8.7076128e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.515 2009  to  Sat Feb 21 18:22:04.515 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4422359e-04 1.0945797e-03 1.1925697e-03 -1.6384506e-01 -5.9925079e-02 8.7076128e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:06.832 2009  to  Sat Feb 21 18:27:06.832 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:07.056 2009  to  Sat Feb 21 18:27:07.056 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:07.287 2009  to  Sat Feb 21 18:27:07.287 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.321 2009  to  Sat Feb 21 18:27:43.321 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.548 2009  to  Sat Feb 21 18:27:43.548 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.776 2009  to  Sat Feb 21 18:27:43.776 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  25  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 18:28:28.785 2009  to  Sat Feb 21 18:28:35.003 2009   (  6.22) secs
                    right PSF SetInstrumentOffsets failed

  26  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:28:28.831 2009  to  Sat Feb 21 18:28:34.955 2009   (  6.12) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 18:28:28.806 2009  to  Sat Feb 21 18:28:34.981 2009   (  6.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  28  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.228 2009  to  Sat Feb 21 18:29:12.228 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.458 2009  to  Sat Feb 21 18:29:12.458 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.687 2009  to  Sat Feb 21 18:29:12.687 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:33:19.636 2009  to  Sat Feb 21 18:33:19.636 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.9464235e-04 1.7926246e-03 -3.1220913e-04 3.6153793e-03 1.8463135e-01 -9.4761848e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:33:19.880 2009  to  Sat Feb 21 18:33:19.880 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.9464235e-04 1.7926246e-03 -3.1220913e-04 3.6153793e-03 1.8463135e-01 -9.4761848e-03

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:43.230 2009  to  Sat Feb 21 19:42:44.166 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  34  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 19:42:44.074 2009  to  Sat Feb 21 19:42:44.382 2009   (  0.31) secs
                    right PSF SetInstrumentOffsets failed

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:44.166 2009  to  Sat Feb 21 19:42:44.318 2009   (  0.15) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  36  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 19:42:44.113 2009  to  Sat Feb 21 19:42:44.349 2009   (  0.24) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  37  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:47.316 2009  to  Sat Feb 21 19:42:47.316 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  38  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:30.661 2009  to  Sat Feb 21 19:44:34.040 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  39  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 19:44:33.772 2009  to  Sat Feb 21 19:44:34.167 2009   (  0.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:34.040 2009  to  Sat Feb 21 19:44:34.133 2009   (  0.09) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  41  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:36.752 2009  to  Sat Feb 21 19:44:36.752 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  42  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 20:34:29.319 2009  to  Sat Feb 21 20:34:29.452 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 20:34:31.541 2009  to  Sat Feb 21 20:34:31.541 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  44  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:04:45.971 2009  to  Sat Feb 21 21:05:09.957 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  45  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:04:45.983 2009  to  Sat Feb 21 21:05:03.323 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  46  FAILED    PSF        command.setZernikes                                           Sat Feb 21 21:04:59.576 2009  to  Sat Feb 21 21:05:03.567 2009   (  3.99) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  47  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 21:04:59.629 2009  to  Sat Feb 21 21:05:03.528 2009   (  3.90) secs
                    right PSF ApplyZernikes failed

  48  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 21:04:59.742 2009  to  Sat Feb 21 21:05:03.501 2009   (  3.76) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:03.323 2009  to  Sat Feb 21 21:05:03.473 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 21:05:06.414 2009  to  Sat Feb 21 21:05:10.131 2009   (  3.72) secs
                    left PSF ApplyZernikes failed

  51  FAILED    PSF        command.setZernikes                                           Sat Feb 21 21:05:06.375 2009  to  Sat Feb 21 21:05:10.162 2009   (  3.79) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  52  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 21:05:06.503 2009  to  Sat Feb 21 21:05:10.099 2009   (  3.60) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:09.957 2009  to  Sat Feb 21 21:05:10.066 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 21:05:15.487 2009  to  Sat Feb 21 21:05:15.870 2009   (  0.38) secs
                    left PSF SetInstrumentOffsets failed

  55  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 21:05:15.514 2009  to  Sat Feb 21 21:05:15.900 2009   (  0.39) secs
                    right PSF SetInstrumentOffsets failed

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:15.583 2009  to  Sat Feb 21 21:05:15.764 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  57  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 21:05:15.530 2009  to  Sat Feb 21 21:05:15.815 2009   (  0.28) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  58  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 21:05:15.565 2009  to  Sat Feb 21 21:05:15.845 2009   (  0.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  59  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:15.617 2009  to  Sat Feb 21 21:05:15.790 2009   (  0.17) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  60  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:27.206 2009  to  Sat Feb 21 21:05:27.206 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  61  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:32.183 2009  to  Sat Feb 21 21:05:32.183 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  62  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 22:05:59.471 2009  to  Sat Feb 21 22:06:05.877 2009   (  6.41) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 22:05:59.737 2009  to  Sat Feb 21 22:06:05.839 2009   (  6.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PSF        command.setZernikes                                           Sat Feb 21 22:51:44.864 2009  to  Sat Feb 21 22:51:55.231 2009   ( 10.37) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  65  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 22:51:44.892 2009  to  Sat Feb 21 22:51:55.183 2009   ( 10.29) secs
                    right PSF ApplyZernikes failed

  66  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 22:51:44.993 2009  to  Sat Feb 21 22:51:55.149 2009   ( 10.16) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 22:51:47.995 2009  to  Sat Feb 21 22:51:55.098 2009   (  7.10) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:06.360 2009  to  Sun Feb 22 01:32:09.827 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Feb 22 01:32:09.647 2009  to  Sun Feb 22 01:32:09.960 2009   (  0.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:09.827 2009  to  Sun Feb 22 01:32:09.917 2009   (  0.09) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  71  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:12.537 2009  to  Sun Feb 22 01:32:12.537 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  72  FAILED    PSF        command.setInstrumentOffsets                                  Sun Feb 22 01:50:33.391 2009  to  Sun Feb 22 01:52:35.898 2009   (122.51) secs
                    right PSF SetInstrumentOffsets failed

  73  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Feb 22 01:50:33.417 2009  to  Sun Feb 22 01:52:35.866 2009   (122.45) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  74  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:50:33.465 2009  to  Sun Feb 22 01:52:35.834 2009   (122.37) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  75  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Feb 22 03:14:31.179 2009  to  Sun Feb 22 03:14:31.648 2009   (  0.47) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Sat Feb 21 17:42:38.060 2009  to  Sat Feb 21 17:42:38.060 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

   2  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 18:08:06.737 2009  to  Sat Feb 21 18:08:06.737 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   3  FAILED    PCS        telescope.telemetryError                                      Sat Feb 21 18:19:25.085 2009  to  Sat Feb 21 18:19:25.085 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   4  FAILED    PCS        telescope.command.startTracking                               Sat Feb 21 18:19:25.125 2009  to  Sat Feb 21 18:19:25.898 2009   (  0.77) secs
                    PCS will start tracking target
                    PCS reports MCSPU error returned - ERROR Cmd. ignored! AZ axis not in AZ_READY state.

   5  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Sat Feb 21 18:19:43.090 2009  to  Sat Feb 21 18:19:43.090 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   6  FAILED    PSF        primaryMirror.command.revert                                  Sat Feb 21 18:21:19.802 2009  to  Sat Feb 21 18:21:37.147 2009   ( 17.35) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.revert                                  Sat Feb 21 18:21:20.975 2009  to  Sat Feb 21 18:21:34.382 2009   ( 13.41) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:21:29.236 2009  to  Sat Feb 21 18:21:34.342 2009   (  5.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:21:29.278 2009  to  Sat Feb 21 18:21:34.303 2009   (  5.02) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:21:34.994 2009  to  Sat Feb 21 18:21:37.094 2009   (  2.10) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:21:35.040 2009  to  Sat Feb 21 18:21:37.061 2009   (  2.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  12  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.357 2009  to  Sat Feb 21 18:22:00.357 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.8136144e-02 3.3091724e-02 2.1480560e-02 2.0082397e+00 -4.6879959e+00 2.3941755e+00

  13  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.611 2009  to  Sat Feb 21 18:22:00.611 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.8136144e-02 3.3091724e-02 2.1480560e-02 2.0082397e+00 -4.6879959e+00 2.3941755e+00

  14  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:00.846 2009  to  Sat Feb 21 18:22:00.846 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9403350e-01 3.4749380e-01 2.1042252e-01 1.4687139e+01 -3.6814201e+01 1.7877968e+01

  15  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.085 2009  to  Sat Feb 21 18:22:01.085 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9403350e-01 3.4749380e-01 2.1042252e-01 1.4687139e+01 -3.6814201e+01 1.7877968e+01

  16  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.326 2009  to  Sat Feb 21 18:22:01.326 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1976960e-01 3.9353898e-01 2.3863578e-01 1.3689726e+01 -3.6829163e+01 1.7642935e+01

  17  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.580 2009  to  Sat Feb 21 18:22:01.580 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1976960e-01 3.9353898e-01 2.3863578e-01 1.3689726e+01 -3.6829163e+01 1.7642935e+01

  18  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:01.814 2009  to  Sat Feb 21 18:22:01.814 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.3541665e-01 4.2211184e-01 2.5736690e-01 9.8381310e+00 -3.1320988e+01 1.4708978e+01

  19  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.050 2009  to  Sat Feb 21 18:22:02.050 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.3541665e-01 4.2211184e-01 2.5736690e-01 9.8381310e+00 -3.1320988e+01 1.4708978e+01

  20  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.291 2009  to  Sat Feb 21 18:22:02.291 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.4095747e-01 2.6006138e-01 1.6049206e-01 5.6386366e+00 -1.9116007e+01 9.0897980e+00

  21  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:02.546 2009  to  Sat Feb 21 18:22:02.546 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.4095747e-01 2.6006138e-01 1.6049206e-01 5.6386366e+00 -1.9116007e+01 9.0897980e+00

  22  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:03.804 2009  to  Sat Feb 21 18:22:03.804 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.7072897e-03 6.1150193e-03 5.5651665e-03 3.7769318e-02 -4.9409485e-01 3.1308916e-01

  23  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.041 2009  to  Sat Feb 21 18:22:04.041 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.7072897e-03 6.1150193e-03 5.5651665e-03 3.7769318e-02 -4.9409485e-01 3.1308916e-01

  24  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.278 2009  to  Sat Feb 21 18:22:04.278 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4422359e-04 1.0945797e-03 1.1925697e-03 -1.6384506e-01 -5.9925079e-02 8.7076128e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:22:04.515 2009  to  Sat Feb 21 18:22:04.515 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4422359e-04 1.0945797e-03 1.1925697e-03 -1.6384506e-01 -5.9925079e-02 8.7076128e-02

  26  FAILED    PMC        VxInterface.close                                             Sat Feb 21 18:22:17.603 2009  to  Sat Feb 21 18:22:17.603 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 18:22:17.585 2009  to  Sat Feb 21 18:22:17.585 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  28  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:06.832 2009  to  Sat Feb 21 18:27:06.832 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:07.056 2009  to  Sat Feb 21 18:27:07.056 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:07.287 2009  to  Sat Feb 21 18:27:07.287 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.321 2009  to  Sat Feb 21 18:27:43.321 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.548 2009  to  Sat Feb 21 18:27:43.548 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:27:43.776 2009  to  Sat Feb 21 18:27:43.776 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1460347e-04 1.3204217e-03 7.6901913e-04 -2.9089212e-02 1.5884399e-01 -3.2675266e-02

  34  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 18:28:28.785 2009  to  Sat Feb 21 18:28:35.003 2009   (  6.22) secs
                    right PSF SetInstrumentOffsets failed

  35  FAILED    IIF        command.moveFocus                                             Sat Feb 21 18:28:28.759 2009  to  Sat Feb 21 18:28:35.062 2009   (  6.30) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488406144675926e+04, time 3.455000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

  36  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 18:28:28.879 2009  to  Sat Feb 21 18:28:34.927 2009   (  6.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 18:28:28.831 2009  to  Sat Feb 21 18:28:34.955 2009   (  6.12) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 18:28:28.806 2009  to  Sat Feb 21 18:28:34.981 2009   (  6.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  39  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.228 2009  to  Sat Feb 21 18:29:12.228 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.458 2009  to  Sat Feb 21 18:29:12.458 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:29:12.687 2009  to  Sat Feb 21 18:29:12.687 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.1221929e-04 2.0130575e-03 7.6282024e-04 -1.7835855e-02 1.6116333e-01 -7.8707218e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:33:19.636 2009  to  Sat Feb 21 18:33:19.636 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.9464235e-04 1.7926246e-03 -3.1220913e-04 3.6153793e-03 1.8463135e-01 -9.4761848e-03

  43  FAILED    PSF        primaryMirror.positionError                                   Sat Feb 21 18:33:19.880 2009  to  Sat Feb 21 18:33:19.880 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.9464235e-04 1.7926246e-03 -3.1220913e-04 3.6153793e-03 1.8463135e-01 -9.4761848e-03

  44  FAILED    PMC        VxInterface.close                                             Sat Feb 21 18:48:50.465 2009  to  Sat Feb 21 18:48:50.465 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 18:48:50.445 2009  to  Sat Feb 21 18:48:50.445 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  46  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 19:20:20.956 2009  to  Sat Feb 21 19:36:28.262 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  47  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 19:20:21.225 2009  to  Sat Feb 21 19:20:21.225 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  48  FAILED    PMC        VxInterface.close                                             Sat Feb 21 19:25:46.445 2009  to  Sat Feb 21 19:25:46.445 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 19:25:46.423 2009  to  Sat Feb 21 19:25:46.423 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  50  FAILED    PCS        guider.telemetryError                                         Sat Feb 21 19:37:40.569 2009  to  Sat Feb 21 19:37:40.569 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:43.230 2009  to  Sat Feb 21 19:42:44.166 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  52  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:43.267 2009  to  Sat Feb 21 19:42:44.231 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

  53  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 19:42:44.074 2009  to  Sat Feb 21 19:42:44.382 2009   (  0.31) secs
                    right PSF SetInstrumentOffsets failed

  54  FAILED    IIF        command.moveFocus                                             Sat Feb 21 19:42:44.043 2009  to  Sat Feb 21 19:42:44.463 2009   (  0.42) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

  55  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:44.166 2009  to  Sat Feb 21 19:42:44.318 2009   (  0.15) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  56  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 19:42:44.113 2009  to  Sat Feb 21 19:42:44.349 2009   (  0.24) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:44.231 2009  to  Sat Feb 21 19:42:44.266 2009   (  0.04) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  58  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:42:47.290 2009  to  Sat Feb 21 19:42:47.290 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  59  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:42:47.316 2009  to  Sat Feb 21 19:42:47.316 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  60  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:30.697 2009  to  Sat Feb 21 19:44:34.076 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  61  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:30.661 2009  to  Sat Feb 21 19:44:34.040 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 19:44:33.772 2009  to  Sat Feb 21 19:44:34.167 2009   (  0.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:34.076 2009  to  Sat Feb 21 19:44:34.097 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:34.040 2009  to  Sat Feb 21 19:44:34.133 2009   (  0.09) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  65  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 19:44:36.725 2009  to  Sat Feb 21 19:44:36.725 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 19:44:36.752 2009  to  Sat Feb 21 19:44:36.752 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  67  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 19:54:16.251 2009  to  Sat Feb 21 19:54:16.251 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  68  FAILED    PMC        VxInterface.close                                             Sat Feb 21 19:54:16.268 2009  to  Sat Feb 21 19:54:16.268 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  69  FAILED    PMC        VxInterface.close                                             Sat Feb 21 20:12:17.019 2009  to  Sat Feb 21 20:12:17.019 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 20:12:17.003 2009  to  Sat Feb 21 20:12:17.003 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Sat Feb 21 20:14:35.996 2009  to  Sat Feb 21 20:14:35.996 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 20:14:35.981 2009  to  Sat Feb 21 20:14:35.981 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  73  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 20:34:29.319 2009  to  Sat Feb 21 20:34:29.452 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  74  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 20:34:29.354 2009  to  Sat Feb 21 20:34:29.486 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

  75  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 20:34:31.510 2009  to  Sat Feb 21 20:34:31.510 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  76  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 20:34:31.541 2009  to  Sat Feb 21 20:34:31.541 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  77  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 20:45:40.631 2009  to  Sat Feb 21 20:51:15.594 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  78  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 20:45:40.898 2009  to  Sat Feb 21 20:45:40.898 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  79  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:03:58.547 2009  to  Sat Feb 21 21:11:41.478 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  80  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:03:58.814 2009  to  Sat Feb 21 21:03:58.814 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  81  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:04:46.026 2009  to  Sat Feb 21 21:05:10.014 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  82  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:04:46.046 2009  to  Sat Feb 21 21:05:03.356 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  83  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:04:45.971 2009  to  Sat Feb 21 21:05:09.957 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  84  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:04:45.983 2009  to  Sat Feb 21 21:05:03.323 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  85  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 21:04:59.509 2009  to  Sat Feb 21 21:05:03.636 2009   (  4.13) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for right LBC for M1

  86  FAILED    PSF        command.setZernikes                                           Sat Feb 21 21:04:59.576 2009  to  Sat Feb 21 21:05:03.567 2009   (  3.99) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  87  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 21:04:59.629 2009  to  Sat Feb 21 21:05:03.528 2009   (  3.90) secs
                    right PSF ApplyZernikes failed

  88  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 21:04:59.742 2009  to  Sat Feb 21 21:05:03.501 2009   (  3.76) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  89  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:03.323 2009  to  Sat Feb 21 21:05:03.473 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  90  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:03.356 2009  to  Sat Feb 21 21:05:03.372 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  91  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 21:05:06.350 2009  to  Sat Feb 21 21:05:10.214 2009   (  3.86) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for left LBC for M1

  92  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 21:05:06.414 2009  to  Sat Feb 21 21:05:10.131 2009   (  3.72) secs
                    left PSF ApplyZernikes failed

  93  FAILED    PSF        command.setZernikes                                           Sat Feb 21 21:05:06.375 2009  to  Sat Feb 21 21:05:10.162 2009   (  3.79) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  94  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 21:05:06.503 2009  to  Sat Feb 21 21:05:10.099 2009   (  3.60) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  95  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:09.957 2009  to  Sat Feb 21 21:05:10.066 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  96  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:10.014 2009  to  Sat Feb 21 21:05:10.036 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  97  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 21:05:15.487 2009  to  Sat Feb 21 21:05:15.870 2009   (  0.38) secs
                    left PSF SetInstrumentOffsets failed

  98  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 21:05:15.514 2009  to  Sat Feb 21 21:05:15.900 2009   (  0.39) secs
                    right PSF SetInstrumentOffsets failed

  99  FAILED    IIF        command.moveFocus                                             Sat Feb 21 21:05:15.444 2009  to  Sat Feb 21 21:05:16.023 2009   (  0.58) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 100  FAILED    IIF        command.moveFocus                                             Sat Feb 21 21:05:15.464 2009  to  Sat Feb 21 21:05:16.039 2009   (  0.57) secs
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 101  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:15.583 2009  to  Sat Feb 21 21:05:15.764 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 102  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 21:05:15.530 2009  to  Sat Feb 21 21:05:15.815 2009   (  0.28) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 103  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 21:05:15.565 2009  to  Sat Feb 21 21:05:15.845 2009   (  0.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 104  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:15.647 2009  to  Sat Feb 21 21:05:15.699 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 105  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:15.678 2009  to  Sat Feb 21 21:05:15.730 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 106  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:15.617 2009  to  Sat Feb 21 21:05:15.790 2009   (  0.17) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 107  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:27.158 2009  to  Sat Feb 21 21:05:27.158 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 108  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:27.206 2009  to  Sat Feb 21 21:05:27.206 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 109  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 21:05:32.152 2009  to  Sat Feb 21 21:05:32.152 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 110  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 21:05:32.183 2009  to  Sat Feb 21 21:05:32.183 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 111  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:11:41.478 2009  to  Sat Feb 21 21:39:16.596 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 112  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:11:41.745 2009  to  Sat Feb 21 21:11:41.745 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 113  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 21:38:44.051 2009  to  Sat Feb 21 21:38:44.051 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 114  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:39:16.596 2009  to  Sat Feb 21 21:53:58.411 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 115  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:39:16.865 2009  to  Sat Feb 21 21:39:16.865 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 116  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:53:58.411 2009  to  Sat Feb 21 22:52:24.381 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 117  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 21:53:58.680 2009  to  Sat Feb 21 21:53:58.680 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 118  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:02:21.212 2009  to  Sat Feb 21 22:02:21.212 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 119  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:02:21.193 2009  to  Sat Feb 21 22:02:21.193 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 120  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:02:39.722 2009  to  Sat Feb 21 22:02:39.722 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 121  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:02:39.690 2009  to  Sat Feb 21 22:02:39.690 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 122  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 22:05:59.471 2009  to  Sat Feb 21 22:06:05.877 2009   (  6.41) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 123  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 22:05:59.777 2009  to  Sat Feb 21 22:06:05.809 2009   (  6.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 124  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 22:05:59.737 2009  to  Sat Feb 21 22:06:05.839 2009   (  6.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 125  FAILED    PSF        command.setZernikes                                           Sat Feb 21 22:51:44.864 2009  to  Sat Feb 21 22:51:55.231 2009   ( 10.37) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 126  FAILED    IIF        command.sendWavefront                                         Sat Feb 21 22:51:44.834 2009  to  Sat Feb 21 22:51:55.288 2009   ( 10.45) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 127  FAILED    PSF        command.applyZernikes                                         Sat Feb 21 22:51:44.892 2009  to  Sat Feb 21 22:51:55.183 2009   ( 10.29) secs
                    right PSF ApplyZernikes failed

 128  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 22:51:44.993 2009  to  Sat Feb 21 22:51:55.149 2009   ( 10.16) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 129  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 22:51:48.034 2009  to  Sat Feb 21 22:51:55.066 2009   (  7.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 130  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 22:51:47.995 2009  to  Sat Feb 21 22:51:55.098 2009   (  7.10) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 131  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 22:52:24.381 2009  to  Sat Feb 21 23:48:48.753 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 132  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 22:52:24.648 2009  to  Sat Feb 21 22:52:24.648 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 133  FAILED    PMC        VxInterface.close                                             Sat Feb 21 22:54:10.640 2009  to  Sat Feb 21 22:54:10.640 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 134  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 22:54:10.625 2009  to  Sat Feb 21 22:54:10.625 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 135  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:08:04.126 2009  to  Sat Feb 21 23:08:04.126 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 136  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:08:04.103 2009  to  Sat Feb 21 23:08:04.103 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 137  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:16:13.445 2009  to  Sat Feb 21 23:16:13.445 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 138  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:16:13.428 2009  to  Sat Feb 21 23:16:13.428 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 139  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:19:28.324 2009  to  Sat Feb 21 23:19:28.324 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

 140  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:19:28.299 2009  to  Sat Feb 21 23:19:28.299 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

 141  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:23:33.181 2009  to  Sat Feb 21 23:23:33.181 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 142  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:23:33.160 2009  to  Sat Feb 21 23:23:33.160 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 143  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:28:11.058 2009  to  Sat Feb 21 23:28:11.058 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:28:11.019 2009  to  Sat Feb 21 23:28:11.019 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 145  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:34:35.960 2009  to  Sat Feb 21 23:34:35.960 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 146  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:34:35.982 2009  to  Sat Feb 21 23:34:35.982 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 147  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:37:01.756 2009  to  Sat Feb 21 23:37:01.756 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:37:01.739 2009  to  Sat Feb 21 23:37:01.739 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 149  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 23:48:48.753 2009  to  Sun Feb 22 00:39:42.222 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 150  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 23:48:49.020 2009  to  Sat Feb 21 23:48:49.020 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 151  FAILED    PMC        VxInterface.close                                             Sat Feb 21 23:52:49.312 2009  to  Sat Feb 21 23:52:49.312 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 152  FAILED    PMC        VxInterface.lengthError                                       Sat Feb 21 23:52:49.295 2009  to  Sat Feb 21 23:52:49.295 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 153  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:01:36.533 2009  to  Sun Feb 22 00:01:36.533 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:01:36.515 2009  to  Sun Feb 22 00:01:36.515 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 155  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:20:02.467 2009  to  Sun Feb 22 00:20:02.467 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

 156  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:20:02.449 2009  to  Sun Feb 22 00:20:02.449 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

 157  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 00:39:42.222 2009  to  Sun Feb 22 00:47:30.816 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 158  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 00:39:42.489 2009  to  Sun Feb 22 00:39:42.489 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 159  FAILED    PMC        VxInterface.close                                             Sun Feb 22 00:55:01.650 2009  to  Sun Feb 22 00:55:01.650 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 160  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 00:55:01.632 2009  to  Sun Feb 22 00:55:01.632 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 161  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 01:17:17.272 2009  to  Sun Feb 22 01:50:16.137 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 162  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 01:17:17.539 2009  to  Sun Feb 22 01:17:17.539 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 163  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:26:49.865 2009  to  Sun Feb 22 01:26:49.865 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 164  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:26:49.846 2009  to  Sun Feb 22 01:26:49.846 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 165  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:06.360 2009  to  Sun Feb 22 01:32:09.827 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 166  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:06.426 2009  to  Sun Feb 22 01:32:09.865 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 167  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Feb 22 01:32:09.647 2009  to  Sun Feb 22 01:32:09.960 2009   (  0.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 168  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:09.827 2009  to  Sun Feb 22 01:32:09.917 2009   (  0.09) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 169  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:09.865 2009  to  Sun Feb 22 01:32:09.882 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 170  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:32:12.505 2009  to  Sun Feb 22 01:32:12.505 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 171  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:32:12.537 2009  to  Sun Feb 22 01:32:12.537 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 172  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:36:45.670 2009  to  Sun Feb 22 01:36:45.670 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 173  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:36:45.655 2009  to  Sun Feb 22 01:36:45.655 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 174  FAILED    PSF        command.setInstrumentOffsets                                  Sun Feb 22 01:50:33.391 2009  to  Sun Feb 22 01:52:35.898 2009   (122.51) secs
                    right PSF SetInstrumentOffsets failed

 175  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sun Feb 22 01:50:33.417 2009  to  Sun Feb 22 01:52:35.866 2009   (122.45) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 176  FAILED    IIF        command.moveFocus                                             Sun Feb 22 01:50:33.364 2009  to  Sun Feb 22 01:52:35.965 2009   (122.60) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

 177  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sun Feb 22 01:50:33.465 2009  to  Sun Feb 22 01:52:35.834 2009   (122.37) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 178  FAILED    PMC        mirror.command.goToPosition.absolute                          Sun Feb 22 01:50:33.529 2009  to  Sun Feb 22 01:52:35.804 2009   (122.27) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 179  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 01:55:23.287 2009  to  Sun Feb 22 01:55:23.287 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

 180  FAILED    PMC        VxInterface.close                                             Sun Feb 22 01:55:23.305 2009  to  Sun Feb 22 01:55:23.305 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

 181  FAILED    PMC        VxInterface.close                                             Sun Feb 22 02:06:08.608 2009  to  Sun Feb 22 02:06:08.608 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 182  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 02:06:08.589 2009  to  Sun Feb 22 02:06:08.589 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 183  FAILED    PMC        VxInterface.lengthError                                       Sun Feb 22 02:14:59.709 2009  to  Sun Feb 22 02:14:59.709 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 184  FAILED    PMC        VxInterface.close                                             Sun Feb 22 02:14:59.733 2009  to  Sun Feb 22 02:14:59.733 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 185  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 02:55:22.354 2009  to  Sun Feb 22 03:27:34.874 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 186  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 02:55:22.625 2009  to  Sun Feb 22 02:55:22.625 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 187  FAILED    PSF        primaryMirror.command.adjustMirror                            Sun Feb 22 03:14:31.179 2009  to  Sun Feb 22 03:14:31.648 2009   (  0.47) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 188  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 03:27:34.874 2009  to  Sun Feb 22 03:52:20.261 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 189  SEQERROR  PCS        telescope.command.startTracking                               Sun Feb 22 03:27:35.141 2009  to  Sun Feb 22 03:27:35.141 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 190  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeFailSet                                    Sun Feb 22 05:32:18.628 2009  to  Sun Feb 22 05:32:18.628 2009   (  0.00) secs
                    Brakes were commanded to set, but they have failed to set. Will release and try to set them again.

 191  FAILED    MCS.MCSPU  MCSPU.ELDrive.BrakeSetRelFail                                 Sun Feb 22 05:32:20.629 2009  to  Sun Feb 22 05:32:20.629 2009   (  0.00) secs
                    Cannot set all brakes or release all brakes.

**********************************************************
    Reporting period ending:   Sun Feb 22 07:24:53.534 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback