You are here: Foswiki>Software Web>TCSSWReportFile_090220 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Feb 20 2009 to Feb 21 2009
 
    Reporting period beginning:   Fri Feb 20 17:39:01.437 2009
    Reporting period ending:      Sat Feb 21 07:26:53.215 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.02    0.10   100.0 %        175        175                      
                                                                       0.01    0.02    0.02    0.10
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.19    0.32    0.14    0.91   100.0 %        591        591                      
                                                                       0.19    0.32    0.14    0.91
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.08    0.05    0.23   100.0 %        710        710                      
                                                                       0.03    0.08    0.05    0.23
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.52    5.91    0.41   53.57    99.0 %        591        585          6           
                                                                       5.12    5.83    2.27   49.52
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.44    4.94    2.55    9.62   100.0 %        124        124                      
                                                                       1.44    4.94    2.55    9.62
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.46    4.33    2.02    9.24   100.0 %        124        124                      
                                                                       1.46    4.33    2.02    9.24
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   14.95   11.00    1.02   43.31   100.0 %         25         25                      
                                                                      14.95   11.00    1.02   43.31
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   28.32   13.10    2.04  100.21   100.0 %         25         25                      
                                                                      28.32   13.10    2.04  100.21
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   41.17   32.43    7.77  142.08    96.0 %         25         24                     1
                                                                      41.17   32.43    7.77  142.08
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    3.16    4.56    0.39   30.64    99.9 %       1060       1059          1           
                                                                       3.17    4.56    0.39   30.64
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.51    3.91    2.26    6.40   100.0 %        116        116                      
                                                                       1.51    3.91    2.26    6.40

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            14

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Fri Feb 20 19:09:27.605 2009  to  Fri Feb 20 19:10:21.178 2009   ( 53.57) secs
                    IIF MoveFocus command started for left LBC for 8.599999999999999e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

   2  FAILED    IIF        command.moveFocus                                             Fri Feb 20 19:10:40.887 2009  to  Fri Feb 20 19:10:41.321 2009   (  0.43) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

   3  FAILED    IIF        command.moveFocus                                             Fri Feb 20 21:50:47.391 2009  to  Fri Feb 20 21:50:47.802 2009   (  0.41) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

   4  FAILED    IIF        command.sendWavefront                                         Fri Feb 20 22:39:36.352 2009  to  Fri Feb 20 22:39:41.089 2009   (  4.74) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for right LBC for M1

   5  FAILED    IIF        command.moveFocus                                             Fri Feb 20 22:39:42.218 2009  to  Fri Feb 20 22:39:42.725 2009   (  0.51) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Sat Feb 21 01:17:40.170 2009  to  Sat Feb 21 01:18:03.694 2009   ( 23.52) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

   7  FAILED    IIF        command.moveFocus                                             Sat Feb 21 06:30:17.737 2009  to  Sat Feb 21 06:30:24.290 2009   (  6.55) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488356270833333e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.610000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4278                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8556                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     108                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         32                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.brakeManPressure . . . . . . . . . . . . . . . .                  3           
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      11                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            12
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      45                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            32
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .       7                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      69                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     716                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     948                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     316                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:43:50.947 2009  to  Fri Feb 20 17:43:50.947 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   2  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:44:07.800 2009  to  Fri Feb 20 17:44:07.800 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:44:41.736 2009  to  Fri Feb 20 17:44:41.736 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 20 17:59:31.748 2009  to  Fri Feb 20 17:59:31.748 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   5  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 20 17:59:35.044 2009  to  Fri Feb 20 17:59:35.044 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.01    0.01    0.07   100.0 %        710        710                      
                                                                       0.01    0.01    0.01    0.07
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.11    0.07    0.24   100.0 %        591        591                      
                                                                       0.02    0.11    0.07    0.24
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.17    0.19    0.01    0.85   100.0 %        124        124                      
                                                                       0.17    0.19    0.01    0.85
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.13    0.18    0.01    0.43   100.0 %         34         34                      
                                                                       0.13    0.18    0.01    0.43
 *** telescope.command.startTracking. . . . . . . . . . . . . . . .    0.32    0.38    0.00    0.78   100.0 %         34         34                      
                                                                       0.13    0.62    0.52    0.78

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  2           
     weather.telemetryError . . . . . . . . . . . . . . . . . . . .                  2           
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  2           

PCS Events of Interest

   1  STARTUP   PCS        startup                                                       Fri Feb 20 17:59:53.698 2009  to  Fri Feb 20 17:59:53.698 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.30b

   2  FAILED    PCS        guider.telemetryError                                         Fri Feb 20 17:59:55.035 2009  to  Fri Feb 20 17:59:55.035 2009   (  0.00) secs
                    PCS Guider telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   3  FAILED    PCS        weather.telemetryError                                        Fri Feb 20 17:59:55.114 2009  to  Fri Feb 20 17:59:55.114 2009   (  0.00) secs
                    PCS Weather telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   4  FAILED    PCS        telescope.telemetryError                                      Fri Feb 20 17:59:55.455 2009  to  Fri Feb 20 17:59:55.455 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   5  FAILED    PCS        weather.telemetryError                                        Fri Feb 20 17:59:55.564 2009  to  Fri Feb 20 17:59:55.564 2009   (  0.00) secs
                    PCS Weather telemetry error: No telemetry since telemeter registration failed.

   6  FAILED    PCS        telescope.telemetryError                                      Fri Feb 20 18:24:38.450 2009  to  Fri Feb 20 18:24:38.450 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   7  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:12:25.606 2009  to  Fri Feb 20 19:15:16.755 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:12:25.875 2009  to  Fri Feb 20 19:12:25.875 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:15:16.755 2009  to  Fri Feb 20 19:23:58.345 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:15:17.024 2009  to  Fri Feb 20 19:15:17.024 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  FAILED    PCS        guider.telemetryError                                         Fri Feb 20 19:25:06.267 2009  to  Fri Feb 20 19:25:06.267 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  12  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:08:57.698 2009  to  Fri Feb 20 20:46:20.036 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  13  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:08:57.965 2009  to  Fri Feb 20 20:08:57.965 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  14  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:46:20.036 2009  to  Fri Feb 20 21:05:34.260 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  15  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:46:20.305 2009  to  Fri Feb 20 20:46:20.305 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  16  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:18:05.076 2009  to  Fri Feb 20 21:29:07.113 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  17  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:18:05.343 2009  to  Fri Feb 20 21:18:05.343 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  18  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:29:07.113 2009  to  Fri Feb 20 21:58:10.915 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  19  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:29:07.384 2009  to  Fri Feb 20 21:29:07.384 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  20  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 22:31:31.721 2009  to  Fri Feb 20 22:46:27.289 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  21  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 22:31:31.989 2009  to  Fri Feb 20 22:31:31.989 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  22  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 01:17:28.822 2009  to  Sat Feb 21 02:08:05.466 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  23  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 01:17:29.090 2009  to  Sat Feb 21 01:17:29.090 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  24  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:17:46.605 2009  to  Sat Feb 21 02:29:45.782 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  25  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:17:46.873 2009  to  Sat Feb 21 02:17:46.873 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  26  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:58:45.886 2009  to  Sat Feb 21 03:28:35.304 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  27  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:58:46.154 2009  to  Sat Feb 21 02:58:46.154 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  28  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 04:04:37.775 2009  to  Sat Feb 21 04:30:24.793 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  29  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 04:04:38.046 2009  to  Sat Feb 21 04:04:38.046 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  30  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:12:53.687 2009  to  Sat Feb 21 05:47:57.815 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  31  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:12:53.955 2009  to  Sat Feb 21 05:12:53.955 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  32  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:47:58.086 2009  to  Sat Feb 21 05:47:58.086 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.01    1.03    1.02    1.06   100.0 %          4          4                      
                                                                       0.01    1.03    1.02    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.95    2.61    2.02    7.06   100.0 %        180        180                      
                                                                       0.95    2.61    2.02    7.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    2.03    2.03    2.03   100.0 %          2          2                      
                                                                       0.00    2.03    2.03    2.03
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.14   66.14   66.14   100.0 %          2          2                      
                                                                       0.00   66.14   66.14   66.14
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .   10.68    5.59    2.02   34.08   100.0 %          9          9                      
                                                                      10.68    5.59    2.02   34.08
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.90    4.88    0.00   53.13    98.9 %       1785       1765         20           
                                                                       4.65    4.84    2.02   49.16
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    1.45  197.53  196.50  198.56     0.0 %          2                     2           
                                                                                                   
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.02    0.09    0.08    0.11   100.0 %          2          2                      
                                                                       0.02    0.09    0.08    0.11

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      10                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      10                      
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  1           
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             5
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             9
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           277
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       2                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     141                      
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             2
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            62
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 65           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 65           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      65                      
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           

PMC Events of Interest

   1  FAILED    PMC        actuator.forceMonitor1.panic                                  Fri Feb 20 18:02:03.719 2009  to  Fri Feb 20 18:02:03.719 2009   (  0.00) secs
                    right PMC Actuator 420 force monitor 1 PANIC! 215.8 lbs, limit is 0.0

   2  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 20 18:03:26.660 2009  to  Fri Feb 20 18:06:45.216 2009   (198.56) secs
                    left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 20 18:03:29.978 2009  to  Fri Feb 20 18:06:46.480 2009   (196.50) secs
                    right PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

   4  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:02.436 2009  to  Fri Feb 20 18:07:06.466 2009   (  4.03) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:03.849 2009  to  Fri Feb 20 18:07:17.899 2009   ( 14.05) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:19.221 2009  to  Fri Feb 20 18:07:22.250 2009   (  3.03) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:26:15.862 2009  to  Fri Feb 20 18:26:44.946 2009   ( 29.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:26:16.990 2009  to  Fri Feb 20 18:26:46.064 2009   ( 29.07) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:36:35.654 2009  to  Fri Feb 20 18:36:35.654 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  10  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:36:35.700 2009  to  Fri Feb 20 18:36:35.700 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  11  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:36:36.674 2009  to  Fri Feb 20 18:36:36.674 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:36:36.654 2009  to  Fri Feb 20 18:36:36.654 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  13  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:37:47.164 2009  to  Fri Feb 20 18:37:47.164 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:37:47.143 2009  to  Fri Feb 20 18:37:47.143 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  15  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:37:48.563 2009  to  Fri Feb 20 18:37:48.563 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  16  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:37:48.543 2009  to  Fri Feb 20 18:37:48.543 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  17  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:50:40.743 2009  to  Fri Feb 20 18:50:40.743 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:50:40.725 2009  to  Fri Feb 20 18:50:40.725 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:09:27.837 2009  to  Fri Feb 20 19:10:20.964 2009   ( 53.13) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:34.705 2009  to  Fri Feb 20 19:10:41.062 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  21  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:41.062 2009  to  Fri Feb 20 19:10:41.087 2009   (  0.03) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  22  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:51.760 2009  to  Fri Feb 20 19:10:51.760 2009   (  0.00) secs
                    Failed event but no Started event
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:54.079 2009  to  Fri Feb 20 19:11:03.118 2009   (  9.04) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:11:10.560 2009  to  Fri Feb 20 19:11:10.560 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  25  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:11:10.539 2009  to  Fri Feb 20 19:11:10.539 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

  26  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:15:54.716 2009  to  Fri Feb 20 19:16:20.782 2009   ( 26.07) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:23:36.876 2009  to  Fri Feb 20 19:23:36.876 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:23:36.858 2009  to  Fri Feb 20 19:23:36.858 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:24:01.247 2009  to  Fri Feb 20 19:24:01.247 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:24:01.220 2009  to  Fri Feb 20 19:24:01.220 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:00:39.087 2009  to  Fri Feb 20 20:00:39.087 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:00:39.103 2009  to  Fri Feb 20 20:00:39.103 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  33  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:00:39.610 2009  to  Fri Feb 20 20:00:39.610 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:00:39.586 2009  to  Fri Feb 20 20:00:39.586 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:24:32.026 2009  to  Fri Feb 20 20:24:32.026 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:24:32.008 2009  to  Fri Feb 20 20:24:32.008 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:26:44.724 2009  to  Fri Feb 20 20:26:44.724 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:26:44.688 2009  to  Fri Feb 20 20:26:44.688 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:41:13.983 2009  to  Fri Feb 20 20:41:13.983 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  40  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:41:13.958 2009  to  Fri Feb 20 20:41:13.958 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:48:26.493 2009  to  Fri Feb 20 20:48:26.493 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  42  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:48:26.544 2009  to  Fri Feb 20 20:48:26.544 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  43  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:07:45.500 2009  to  Fri Feb 20 21:07:45.500 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  44  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:07:45.477 2009  to  Fri Feb 20 21:07:45.477 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:07:52.220 2009  to  Fri Feb 20 21:07:52.220 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  46  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:07:52.249 2009  to  Fri Feb 20 21:07:52.249 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  47  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:13:16.312 2009  to  Fri Feb 20 21:13:16.312 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  48  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:13:16.269 2009  to  Fri Feb 20 21:13:16.269 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:39:56.956 2009  to  Fri Feb 20 21:39:56.956 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:39:56.929 2009  to  Fri Feb 20 21:39:56.929 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  51  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:42:03.341 2009  to  Fri Feb 20 21:42:03.341 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  52  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:42:03.310 2009  to  Fri Feb 20 21:42:03.310 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  53  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:46.339 2009  to  Fri Feb 20 21:50:47.544 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:47.544 2009  to  Fri Feb 20 21:50:47.590 2009   (  0.05) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:50.372 2009  to  Fri Feb 20 21:50:50.372 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  56  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:09:45.539 2009  to  Fri Feb 20 22:09:45.539 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:09:45.574 2009  to  Fri Feb 20 22:09:45.574 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:11:49.914 2009  to  Fri Feb 20 22:11:49.914 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:11:49.882 2009  to  Fri Feb 20 22:11:49.882 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:14:21.149 2009  to  Fri Feb 20 22:14:21.149 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:14:21.118 2009  to  Fri Feb 20 22:14:21.118 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  62  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:20.335 2009  to  Fri Feb 20 22:15:21.734 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  63  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:21.734 2009  to  Fri Feb 20 22:15:21.757 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:23.366 2009  to  Fri Feb 20 22:15:23.366 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  65  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:21:34.180 2009  to  Fri Feb 20 22:21:34.180 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:21:34.153 2009  to  Fri Feb 20 22:21:34.153 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:24:47.024 2009  to  Fri Feb 20 22:24:47.024 2009   (  0.00) secs
                    left PMC Motor length error: expected 40, got 96

  68  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:24:47.052 2009  to  Fri Feb 20 22:24:47.052 2009   (  0.00) secs
                    left PMC Motor closing network connection

  69  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:36.919 2009  to  Fri Feb 20 22:39:40.807 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:40.807 2009  to  Fri Feb 20 22:39:40.832 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  71  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:42.439 2009  to  Fri Feb 20 22:39:42.492 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  72  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:43.958 2009  to  Fri Feb 20 22:39:43.958 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  73  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:44:26.876 2009  to  Fri Feb 20 22:44:26.876 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:44:26.846 2009  to  Fri Feb 20 22:44:26.846 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  75  FAILED    PMC        thermal.badReceive                                            Fri Feb 20 23:08:00.279 2009  to  Fri Feb 20 23:08:00.279 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  76  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:22.493 2009  to  Sat Feb 21 00:08:26.017 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  77  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:26.017 2009  to  Sat Feb 21 00:08:26.051 2009   (  0.03) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  78  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:28.534 2009  to  Sat Feb 21 00:08:28.534 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  79  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:27:49.347 2009  to  Sat Feb 21 00:27:51.698 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

  80  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 02:50:20.352 2009  to  Sat Feb 21 02:50:20.352 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.16    4.41    0.27   30.43    99.9 %       1060       1059          1           
                                                                       3.16    4.41    0.27   30.43
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.05   100.0 %         50         50                      
                                                                       0.01    0.03    0.02    0.05
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.13    5.49    0.29   53.38    99.2 %        707        701          6           
                                                                       4.76    5.41    2.19   49.43
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.16    4.47    0.32   30.53    99.9 %       1060       1059          1           
                                                                       3.16    4.47    0.32   30.53
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    3.13    4.28    0.00   30.28    99.4 %       1136       1129          7           
                                                                       3.12    4.30    0.15   30.28
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.90    4.97    0.00   53.22    98.9 %       1785       1765         20           
                                                                       4.65    4.94    2.08   49.26
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .   10.68    5.67    2.09   34.14   100.0 %          9          9                      
                                                                      10.68    5.67    2.09   34.14
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.01    2.11    2.10    2.11   100.0 %          2          2                      
                                                                       0.01    2.11    2.10    2.11
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.08    0.04    0.49   100.0 %        315        315                      
                                                                       0.04    0.08    0.04    0.49
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    7.06   11.32    6.32   16.31     0.0 %          2                     2           
                                                                                                   
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    0.00   27.23   27.23   27.23   100.0 %          1          1                      
                                                                       0.00   27.23   27.23   27.23
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.13    5.41    0.22   53.30    99.2 %        707        701          6           
                                                                       4.76    5.34    2.14   49.35
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.04    0.03    0.09   100.0 %         58         58                      
                                                                       0.01    0.04    0.03    0.09
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.03    0.02    0.11   100.0 %       1118       1118                      
                                                                       0.01    0.03    0.02    0.11

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1644           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 18:07:00.215 2009  to  Fri Feb 20 18:07:06.539 2009   (  6.32) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 18:07:01.647 2009  to  Fri Feb 20 18:07:17.961 2009   ( 16.31) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:02.397 2009  to  Fri Feb 20 18:07:06.507 2009   (  4.11) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:03.811 2009  to  Fri Feb 20 18:07:17.932 2009   ( 14.12) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 18:07:13.612 2009  to  Fri Feb 20 18:07:22.316 2009   (  8.70) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:19.162 2009  to  Fri Feb 20 18:07:22.284 2009   (  3.12) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:26:15.818 2009  to  Fri Feb 20 18:26:44.980 2009   ( 29.16) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:26:16.953 2009  to  Fri Feb 20 18:26:46.100 2009   ( 29.15) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.533 2009  to  Fri Feb 20 18:28:56.533 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.7498298e-04 2.1393299e-03 1.0290146e-03 6.3564301e-02 1.9165993e-01 -7.8332424e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.767 2009  to  Fri Feb 20 18:28:56.767 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.7498298e-04 2.1393299e-03 1.0290146e-03 6.3564301e-02 1.9165993e-01 -7.8332424e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.998 2009  to  Fri Feb 20 18:28:56.998 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.1238151e-04 1.8422604e-03 8.4626675e-04 5.6957245e-02 1.6979408e-01 -6.7977428e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:57.227 2009  to  Fri Feb 20 18:28:57.227 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.1238151e-04 1.8422604e-03 8.4626675e-04 5.6957245e-02 1.6979408e-01 -6.7977428e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:37:19.993 2009  to  Fri Feb 20 18:37:19.993 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -5.3295493e-04 -2.3168325e-03 -4.8243999e-04 1.2477875e-02 -1.6990280e-01 -1.0706902e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:37:20.229 2009  to  Fri Feb 20 18:37:20.229 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -5.3295493e-04 -2.3168325e-03 -4.8243999e-04 1.2477875e-02 -1.6990280e-01 -1.0706902e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:38:34.303 2009  to  Fri Feb 20 18:38:34.303 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.7031722e-04 7.9059601e-04 7.9035759e-04 5.7884216e-02 1.5580368e-01 -3.0851841e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:38:34.559 2009  to  Fri Feb 20 18:38:34.559 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.7031722e-04 7.9059601e-04 7.9035759e-04 5.7884216e-02 1.5580368e-01 -3.0851841e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:11.113 2009  to  Fri Feb 20 18:40:11.113 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.5074015e-04 -1.8827915e-03 -3.6704540e-04 3.0509949e-02 -1.6161537e-01 -3.4818411e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:13.967 2009  to  Fri Feb 20 18:40:13.967 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.7010522e-04 -1.6493797e-03 -1.2445450e-03 -7.7152252e-02 -1.5098000e-01 6.1572790e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:14.201 2009  to  Fri Feb 20 18:40:14.201 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.7010522e-04 -1.6493797e-03 -1.2445450e-03 -7.7152252e-02 -1.5098000e-01 6.1572790e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:27.998 2009  to  Fri Feb 20 18:40:27.998 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.9031763e-04 -1.8860102e-03 -7.3516369e-04 8.0451965e-03 -1.6656494e-01 -1.3966799e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:28.233 2009  to  Fri Feb 20 18:40:28.233 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.9031763e-04 -1.8860102e-03 -7.3516369e-04 8.0451965e-03 -1.6656494e-01 -1.3966799e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.108 2009  to  Fri Feb 20 18:42:55.108 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  23  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.337 2009  to  Fri Feb 20 18:42:55.337 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  24  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.565 2009  to  Fri Feb 20 18:42:55.565 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  25  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:03.894 2009  to  Fri Feb 20 18:43:03.894 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:04.131 2009  to  Fri Feb 20 18:43:04.131 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:04.363 2009  to  Fri Feb 20 18:43:04.363 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:05.002 2009  to  Fri Feb 20 18:43:05.002 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.8065863e-05 -2.2948980e-03 -4.3964386e-04 1.7280579e-03 -1.6117477e-01 3.6294460e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:05.232 2009  to  Fri Feb 20 18:43:05.232 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.8065863e-05 -2.2948980e-03 -4.3964386e-04 1.7280579e-03 -1.6117477e-01 3.6294460e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.125 2009  to  Fri Feb 20 18:43:11.125 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.351 2009  to  Fri Feb 20 18:43:11.351 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.578 2009  to  Fri Feb 20 18:43:11.578 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:24.765 2009  to  Fri Feb 20 18:43:24.765 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.3004751e-04 -2.2962093e-03 4.7981739e-04 2.4311066e-02 -1.5651131e-01 -1.5788555e-02

  34  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 19:09:27.670 2009  to  Fri Feb 20 19:10:21.051 2009   ( 53.38) secs
                    right PSF SetInstrumentOffsets failed

  35  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 19:09:27.721 2009  to  Fri Feb 20 19:10:21.023 2009   ( 53.30) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:09:27.774 2009  to  Fri Feb 20 19:10:20.997 2009   ( 53.22) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:34.666 2009  to  Fri Feb 20 19:10:40.984 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  38  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 19:10:40.927 2009  to  Fri Feb 20 19:10:41.234 2009   (  0.31) secs
                    right PSF SetInstrumentOffsets failed

  39  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:40.984 2009  to  Fri Feb 20 19:10:41.123 2009   (  0.14) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 19:10:40.952 2009  to  Fri Feb 20 19:10:41.178 2009   (  0.23) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  41  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:51.796 2009  to  Fri Feb 20 19:10:51.796 2009   (  0.00) secs
                    Failed event but no Started event
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:54.042 2009  to  Fri Feb 20 19:11:03.154 2009   (  9.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:15:54.680 2009  to  Fri Feb 20 19:16:20.845 2009   ( 26.17) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 21:35:39.298 2009  to  Fri Feb 20 21:35:44.486 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  45  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 21:35:48.920 2009  to  Fri Feb 20 21:35:48.920 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  46  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:46.307 2009  to  Fri Feb 20 21:50:47.506 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  47  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 21:50:47.440 2009  to  Fri Feb 20 21:50:47.731 2009   (  0.29) secs
                    left PSF SetInstrumentOffsets failed

  48  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 21:50:47.467 2009  to  Fri Feb 20 21:50:47.684 2009   (  0.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  49  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:47.506 2009  to  Fri Feb 20 21:50:47.645 2009   (  0.14) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:50.423 2009  to  Fri Feb 20 21:50:50.423 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  51  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:20.130 2009  to  Fri Feb 20 22:15:21.511 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  52  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:20.296 2009  to  Fri Feb 20 22:15:21.691 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:21.511 2009  to  Fri Feb 20 22:15:21.853 2009   (  0.34) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:21.691 2009  to  Fri Feb 20 22:15:21.797 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:23.406 2009  to  Fri Feb 20 22:15:23.406 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  56  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:23.433 2009  to  Fri Feb 20 22:15:23.433 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  57  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:36.227 2009  to  Fri Feb 20 22:39:36.506 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF adjusting primary mirror forces

  58  FAILED    PSF        command.applyZernikes                                         Fri Feb 20 22:39:36.414 2009  to  Fri Feb 20 22:39:40.936 2009   (  4.52) secs
                    right PSF ApplyZernikes failed

  59  FAILED    PSF        command.setZernikes                                           Fri Feb 20 22:39:36.383 2009  to  Fri Feb 20 22:39:40.970 2009   (  4.59) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  60  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:36.506 2009  to  Fri Feb 20 22:39:40.907 2009   (  4.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  61  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:36.857 2009  to  Fri Feb 20 22:39:40.765 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:40.765 2009  to  Fri Feb 20 22:39:40.872 2009   (  0.11) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  63  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 22:39:42.274 2009  to  Fri Feb 20 22:39:42.645 2009   (  0.37) secs
                    right PSF SetInstrumentOffsets failed

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:42.378 2009  to  Fri Feb 20 22:39:42.557 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  65  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 22:39:42.326 2009  to  Fri Feb 20 22:39:42.608 2009   (  0.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:44.023 2009  to  Fri Feb 20 22:39:44.023 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  67  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:44.081 2009  to  Fri Feb 20 22:39:44.081 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror force adjustments complete

  68  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:22.455 2009  to  Sat Feb 21 00:08:25.971 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 00:08:25.750 2009  to  Sat Feb 21 00:08:26.152 2009   (  0.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:25.971 2009  to  Sat Feb 21 00:08:26.117 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  71  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:28.576 2009  to  Sat Feb 21 00:08:28.576 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  72  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:27:49.284 2009  to  Sat Feb 21 00:27:51.635 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  73  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 00:27:51.375 2009  to  Sat Feb 21 00:27:51.831 2009   (  0.46) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  74  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 01:17:40.219 2009  to  Sat Feb 21 01:18:03.605 2009   ( 23.39) secs
                    right PSF SetInstrumentOffsets failed

  75  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 01:17:40.270 2009  to  Sat Feb 21 01:18:03.549 2009   ( 23.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  76  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 01:19:57.063 2009  to  Sat Feb 21 01:19:57.525 2009   (  0.46) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  77  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 01:21:36.065 2009  to  Sat Feb 21 01:21:36.449 2009   (  0.38) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  78  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 06:30:17.806 2009  to  Sat Feb 21 06:30:24.191 2009   (  6.39) secs
                    right PSF SetInstrumentOffsets failed

  79  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 06:30:17.855 2009  to  Sat Feb 21 06:30:24.131 2009   (  6.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:43:50.947 2009  to  Fri Feb 20 17:43:50.947 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   2  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:44:07.800 2009  to  Fri Feb 20 17:44:07.800 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   3  FAILED    MCS.MCSPU  MCSPU.ELDrive.brakeManPressure                                Fri Feb 20 17:44:41.736 2009  to  Fri Feb 20 17:44:41.736 2009   (  0.00) secs
                    Brake manifold pressure is too low.

   4  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 20 17:59:31.748 2009  to  Fri Feb 20 17:59:31.748 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   5  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Feb 20 17:59:35.044 2009  to  Fri Feb 20 17:59:35.044 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   6  STARTUP   PCS        startup                                                       Fri Feb 20 17:59:53.698 2009  to  Fri Feb 20 17:59:53.698 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.30b

   7  FAILED    PCS        guider.telemetryError                                         Fri Feb 20 17:59:55.035 2009  to  Fri Feb 20 17:59:55.035 2009   (  0.00) secs
                    PCS Guider telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   8  FAILED    PCS        weather.telemetryError                                        Fri Feb 20 17:59:55.114 2009  to  Fri Feb 20 17:59:55.114 2009   (  0.00) secs
                    PCS Weather telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   9  FAILED    PCS        telescope.telemetryError                                      Fri Feb 20 17:59:55.455 2009  to  Fri Feb 20 17:59:55.455 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

  10  FAILED    PCS        weather.telemetryError                                        Fri Feb 20 17:59:55.564 2009  to  Fri Feb 20 17:59:55.564 2009   (  0.00) secs
                    PCS Weather telemetry error: No telemetry since telemeter registration failed.

  11  FAILED    PMC        actuator.forceMonitor1.panic                                  Fri Feb 20 18:02:03.719 2009  to  Fri Feb 20 18:02:03.719 2009   (  0.00) secs
                    right PMC Actuator 420 force monitor 1 PANIC! 215.8 lbs, limit is 0.0

  12  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 20 18:03:26.660 2009  to  Fri Feb 20 18:06:45.216 2009   (198.56) secs
                    left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

  13  FAILED    PMC        mirror.command.raise.auto                                     Fri Feb 20 18:03:29.978 2009  to  Fri Feb 20 18:06:46.480 2009   (196.50) secs
                    right PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

  14  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 18:07:00.215 2009  to  Fri Feb 20 18:07:06.539 2009   (  6.32) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 18:07:01.647 2009  to  Fri Feb 20 18:07:17.961 2009   ( 16.31) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:02.436 2009  to  Fri Feb 20 18:07:06.466 2009   (  4.03) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:02.397 2009  to  Fri Feb 20 18:07:06.507 2009   (  4.11) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:03.849 2009  to  Fri Feb 20 18:07:17.899 2009   ( 14.05) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:03.811 2009  to  Fri Feb 20 18:07:17.932 2009   ( 14.12) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 18:07:13.612 2009  to  Fri Feb 20 18:07:22.316 2009   (  8.70) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:07:19.221 2009  to  Fri Feb 20 18:07:22.250 2009   (  3.03) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:07:19.162 2009  to  Fri Feb 20 18:07:22.284 2009   (  3.12) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  FAILED    PCS        telescope.telemetryError                                      Fri Feb 20 18:24:38.450 2009  to  Fri Feb 20 18:24:38.450 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:26:15.818 2009  to  Fri Feb 20 18:26:44.980 2009   ( 29.16) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:26:15.862 2009  to  Fri Feb 20 18:26:44.946 2009   ( 29.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  26  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 18:26:16.953 2009  to  Fri Feb 20 18:26:46.100 2009   ( 29.15) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 18:26:16.990 2009  to  Fri Feb 20 18:26:46.064 2009   ( 29.07) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  28  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.533 2009  to  Fri Feb 20 18:28:56.533 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.7498298e-04 2.1393299e-03 1.0290146e-03 6.3564301e-02 1.9165993e-01 -7.8332424e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.767 2009  to  Fri Feb 20 18:28:56.767 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 9.7498298e-04 2.1393299e-03 1.0290146e-03 6.3564301e-02 1.9165993e-01 -7.8332424e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:56.998 2009  to  Fri Feb 20 18:28:56.998 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.1238151e-04 1.8422604e-03 8.4626675e-04 5.6957245e-02 1.6979408e-01 -6.7977428e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:28:57.227 2009  to  Fri Feb 20 18:28:57.227 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.1238151e-04 1.8422604e-03 8.4626675e-04 5.6957245e-02 1.6979408e-01 -6.7977428e-02

  32  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:36:35.654 2009  to  Fri Feb 20 18:36:35.654 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:36:35.700 2009  to  Fri Feb 20 18:36:35.700 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:36:36.674 2009  to  Fri Feb 20 18:36:36.674 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:36:36.654 2009  to  Fri Feb 20 18:36:36.654 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  36  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:37:19.993 2009  to  Fri Feb 20 18:37:19.993 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -5.3295493e-04 -2.3168325e-03 -4.8243999e-04 1.2477875e-02 -1.6990280e-01 -1.0706902e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:37:20.229 2009  to  Fri Feb 20 18:37:20.229 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -5.3295493e-04 -2.3168325e-03 -4.8243999e-04 1.2477875e-02 -1.6990280e-01 -1.0706902e-02

  38  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:37:47.164 2009  to  Fri Feb 20 18:37:47.164 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:37:47.143 2009  to  Fri Feb 20 18:37:47.143 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:37:48.563 2009  to  Fri Feb 20 18:37:48.563 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:37:48.543 2009  to  Fri Feb 20 18:37:48.543 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  42  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:38:34.303 2009  to  Fri Feb 20 18:38:34.303 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.7031722e-04 7.9059601e-04 7.9035759e-04 5.7884216e-02 1.5580368e-01 -3.0851841e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:38:34.559 2009  to  Fri Feb 20 18:38:34.559 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.7031722e-04 7.9059601e-04 7.9035759e-04 5.7884216e-02 1.5580368e-01 -3.0851841e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:11.113 2009  to  Fri Feb 20 18:40:11.113 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 1.5074015e-04 -1.8827915e-03 -3.6704540e-04 3.0509949e-02 -1.6161537e-01 -3.4818411e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:13.967 2009  to  Fri Feb 20 18:40:13.967 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.7010522e-04 -1.6493797e-03 -1.2445450e-03 -7.7152252e-02 -1.5098000e-01 6.1572790e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:14.201 2009  to  Fri Feb 20 18:40:14.201 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -6.7010522e-04 -1.6493797e-03 -1.2445450e-03 -7.7152252e-02 -1.5098000e-01 6.1572790e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:27.998 2009  to  Fri Feb 20 18:40:27.998 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.9031763e-04 -1.8860102e-03 -7.3516369e-04 8.0451965e-03 -1.6656494e-01 -1.3966799e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:40:28.233 2009  to  Fri Feb 20 18:40:28.233 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.9031763e-04 -1.8860102e-03 -7.3516369e-04 8.0451965e-03 -1.6656494e-01 -1.3966799e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.108 2009  to  Fri Feb 20 18:42:55.108 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  50  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.337 2009  to  Fri Feb 20 18:42:55.337 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  51  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:42:55.565 2009  to  Fri Feb 20 18:42:55.565 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.6997280e-04 -2.2883415e-03 2.9623508e-04 4.6634674e-02 -1.5127945e-01 -5.3944588e-03

  52  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:03.894 2009  to  Fri Feb 20 18:43:03.894 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  53  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:04.131 2009  to  Fri Feb 20 18:43:04.131 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  54  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:04.363 2009  to  Fri Feb 20 18:43:04.363 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -2.5182962e-04 -2.3027658e-03 -2.5618076e-04 -2.0595551e-02 -1.6640663e-01 2.5900364e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:05.002 2009  to  Fri Feb 20 18:43:05.002 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.8065863e-05 -2.2948980e-03 -4.3964386e-04 1.7280579e-03 -1.6117477e-01 3.6294460e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:05.232 2009  to  Fri Feb 20 18:43:05.232 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.8065863e-05 -2.2948980e-03 -4.3964386e-04 1.7280579e-03 -1.6117477e-01 3.6294460e-02

  57  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.125 2009  to  Fri Feb 20 18:43:11.125 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  58  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.351 2009  to  Fri Feb 20 18:43:11.351 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  59  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:11.578 2009  to  Fri Feb 20 18:43:11.578 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 8.9168549e-05 -2.2994280e-03 1.1181831e-04 1.8615723e-03 -1.6145134e-01 5.0520897e-03

  60  FAILED    PSF        primaryMirror.positionError                                   Fri Feb 20 18:43:24.765 2009  to  Fri Feb 20 18:43:24.765 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 4.3004751e-04 -2.2962093e-03 4.7981739e-04 2.4311066e-02 -1.5651131e-01 -1.5788555e-02

  61  FAILED    PMC        VxInterface.close                                             Fri Feb 20 18:50:40.743 2009  to  Fri Feb 20 18:50:40.743 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 18:50:40.725 2009  to  Fri Feb 20 18:50:40.725 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  63  FAILED    IIF        command.moveFocus                                             Fri Feb 20 19:09:27.605 2009  to  Fri Feb 20 19:10:21.178 2009   ( 53.57) secs
                    IIF MoveFocus command started for left LBC for 8.599999999999999e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

  64  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 19:09:27.670 2009  to  Fri Feb 20 19:10:21.051 2009   ( 53.38) secs
                    right PSF SetInstrumentOffsets failed

  65  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 19:09:27.721 2009  to  Fri Feb 20 19:10:21.023 2009   ( 53.30) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:09:27.774 2009  to  Fri Feb 20 19:10:20.997 2009   ( 53.22) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:09:27.837 2009  to  Fri Feb 20 19:10:20.964 2009   ( 53.13) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:34.705 2009  to  Fri Feb 20 19:10:41.062 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:34.666 2009  to  Fri Feb 20 19:10:40.984 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  70  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 19:10:40.927 2009  to  Fri Feb 20 19:10:41.234 2009   (  0.31) secs
                    right PSF SetInstrumentOffsets failed

  71  FAILED    IIF        command.moveFocus                                             Fri Feb 20 19:10:40.887 2009  to  Fri Feb 20 19:10:41.321 2009   (  0.43) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

  72  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:40.984 2009  to  Fri Feb 20 19:10:41.123 2009   (  0.14) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  73  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 19:10:40.952 2009  to  Fri Feb 20 19:10:41.178 2009   (  0.23) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  74  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:41.062 2009  to  Fri Feb 20 19:10:41.087 2009   (  0.03) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  75  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:51.760 2009  to  Fri Feb 20 19:10:51.760 2009   (  0.00) secs
                    Failed event but no Started event
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  76  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:51.796 2009  to  Fri Feb 20 19:10:51.796 2009   (  0.00) secs
                    Failed event but no Started event
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  77  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:10:54.042 2009  to  Fri Feb 20 19:11:03.154 2009   (  9.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:10:54.079 2009  to  Fri Feb 20 19:11:03.118 2009   (  9.04) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:11:10.560 2009  to  Fri Feb 20 19:11:10.560 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  80  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:11:10.539 2009  to  Fri Feb 20 19:11:10.539 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

  81  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:12:25.606 2009  to  Fri Feb 20 19:15:16.755 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  82  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:12:25.875 2009  to  Fri Feb 20 19:12:25.875 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  83  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:15:16.755 2009  to  Fri Feb 20 19:23:58.345 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  84  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 19:15:17.024 2009  to  Fri Feb 20 19:15:17.024 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  85  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 19:15:54.716 2009  to  Fri Feb 20 19:16:20.782 2009   ( 26.07) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  86  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 19:15:54.680 2009  to  Fri Feb 20 19:16:20.845 2009   ( 26.17) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:23:36.876 2009  to  Fri Feb 20 19:23:36.876 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  88  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:23:36.858 2009  to  Fri Feb 20 19:23:36.858 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  89  FAILED    PMC        VxInterface.close                                             Fri Feb 20 19:24:01.247 2009  to  Fri Feb 20 19:24:01.247 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  90  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 19:24:01.220 2009  to  Fri Feb 20 19:24:01.220 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  91  FAILED    PCS        guider.telemetryError                                         Fri Feb 20 19:25:06.267 2009  to  Fri Feb 20 19:25:06.267 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  92  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:00:39.087 2009  to  Fri Feb 20 20:00:39.087 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  93  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:00:39.103 2009  to  Fri Feb 20 20:00:39.103 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  94  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:00:39.610 2009  to  Fri Feb 20 20:00:39.610 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  95  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:00:39.586 2009  to  Fri Feb 20 20:00:39.586 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  96  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:08:57.698 2009  to  Fri Feb 20 20:46:20.036 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  97  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:08:57.965 2009  to  Fri Feb 20 20:08:57.965 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  98  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:24:32.026 2009  to  Fri Feb 20 20:24:32.026 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  99  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:24:32.008 2009  to  Fri Feb 20 20:24:32.008 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 100  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:26:44.724 2009  to  Fri Feb 20 20:26:44.724 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 101  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:26:44.688 2009  to  Fri Feb 20 20:26:44.688 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 102  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:41:13.983 2009  to  Fri Feb 20 20:41:13.983 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 103  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:41:13.958 2009  to  Fri Feb 20 20:41:13.958 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 104  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:46:20.036 2009  to  Fri Feb 20 21:05:34.260 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 105  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 20:46:20.305 2009  to  Fri Feb 20 20:46:20.305 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 106  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 20:48:26.493 2009  to  Fri Feb 20 20:48:26.493 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 107  FAILED    PMC        VxInterface.close                                             Fri Feb 20 20:48:26.544 2009  to  Fri Feb 20 20:48:26.544 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 108  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:07:45.500 2009  to  Fri Feb 20 21:07:45.500 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 109  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:07:45.477 2009  to  Fri Feb 20 21:07:45.477 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 110  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:07:52.220 2009  to  Fri Feb 20 21:07:52.220 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 111  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:07:52.249 2009  to  Fri Feb 20 21:07:52.249 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 112  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:13:16.312 2009  to  Fri Feb 20 21:13:16.312 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 113  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:13:16.269 2009  to  Fri Feb 20 21:13:16.269 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 114  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:18:05.076 2009  to  Fri Feb 20 21:29:07.113 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 115  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:18:05.343 2009  to  Fri Feb 20 21:18:05.343 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 116  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:29:07.113 2009  to  Fri Feb 20 21:58:10.915 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 117  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 21:29:07.384 2009  to  Fri Feb 20 21:29:07.384 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 118  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 21:35:39.298 2009  to  Fri Feb 20 21:35:44.486 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

 119  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 21:35:48.920 2009  to  Fri Feb 20 21:35:48.920 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

 120  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:39:56.956 2009  to  Fri Feb 20 21:39:56.956 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 121  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:39:56.929 2009  to  Fri Feb 20 21:39:56.929 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 122  FAILED    PMC        VxInterface.close                                             Fri Feb 20 21:42:03.341 2009  to  Fri Feb 20 21:42:03.341 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 123  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 21:42:03.310 2009  to  Fri Feb 20 21:42:03.310 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 124  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:46.339 2009  to  Fri Feb 20 21:50:47.544 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 125  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:46.307 2009  to  Fri Feb 20 21:50:47.506 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 126  FAILED    IIF        command.moveFocus                                             Fri Feb 20 21:50:47.391 2009  to  Fri Feb 20 21:50:47.802 2009   (  0.41) secs
                    IIF MoveFocus command started for left LBC for 5.300000000000000e-02
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

 127  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 21:50:47.440 2009  to  Fri Feb 20 21:50:47.731 2009   (  0.29) secs
                    left PSF SetInstrumentOffsets failed

 128  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 21:50:47.467 2009  to  Fri Feb 20 21:50:47.684 2009   (  0.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 129  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:47.544 2009  to  Fri Feb 20 21:50:47.590 2009   (  0.05) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 130  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:47.506 2009  to  Fri Feb 20 21:50:47.645 2009   (  0.14) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 131  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 21:50:50.372 2009  to  Fri Feb 20 21:50:50.372 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 132  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 21:50:50.423 2009  to  Fri Feb 20 21:50:50.423 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 133  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:09:45.539 2009  to  Fri Feb 20 22:09:45.539 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 134  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:09:45.574 2009  to  Fri Feb 20 22:09:45.574 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 135  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:11:49.914 2009  to  Fri Feb 20 22:11:49.914 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 136  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:11:49.882 2009  to  Fri Feb 20 22:11:49.882 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 137  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:14:21.149 2009  to  Fri Feb 20 22:14:21.149 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 138  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:14:21.118 2009  to  Fri Feb 20 22:14:21.118 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 139  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:20.130 2009  to  Fri Feb 20 22:15:21.511 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

 140  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:20.335 2009  to  Fri Feb 20 22:15:21.734 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 141  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:20.296 2009  to  Fri Feb 20 22:15:21.691 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 142  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:21.511 2009  to  Fri Feb 20 22:15:21.853 2009   (  0.34) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 143  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:21.691 2009  to  Fri Feb 20 22:15:21.797 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 144  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:21.734 2009  to  Fri Feb 20 22:15:21.757 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 145  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:15:23.366 2009  to  Fri Feb 20 22:15:23.366 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 146  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:15:23.406 2009  to  Fri Feb 20 22:15:23.406 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 147  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:15:23.433 2009  to  Fri Feb 20 22:15:23.433 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

 148  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:21:34.180 2009  to  Fri Feb 20 22:21:34.180 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 149  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:21:34.153 2009  to  Fri Feb 20 22:21:34.153 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 150  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:24:47.024 2009  to  Fri Feb 20 22:24:47.024 2009   (  0.00) secs
                    left PMC Motor length error: expected 40, got 96

 151  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:24:47.052 2009  to  Fri Feb 20 22:24:47.052 2009   (  0.00) secs
                    left PMC Motor closing network connection

 152  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 22:31:31.721 2009  to  Fri Feb 20 22:46:27.289 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 153  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 22:31:31.989 2009  to  Fri Feb 20 22:31:31.989 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 154  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:36.227 2009  to  Fri Feb 20 22:39:36.506 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF adjusting primary mirror forces

 155  FAILED    IIF        command.sendWavefront                                         Fri Feb 20 22:39:36.352 2009  to  Fri Feb 20 22:39:41.089 2009   (  4.74) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF SendWavefront command failed for right LBC for M1

 156  FAILED    PSF        command.applyZernikes                                         Fri Feb 20 22:39:36.414 2009  to  Fri Feb 20 22:39:40.936 2009   (  4.52) secs
                    right PSF ApplyZernikes failed

 157  FAILED    PSF        command.setZernikes                                           Fri Feb 20 22:39:36.383 2009  to  Fri Feb 20 22:39:40.970 2009   (  4.59) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 158  FAILED    PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:36.506 2009  to  Fri Feb 20 22:39:40.907 2009   (  4.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 159  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:36.857 2009  to  Fri Feb 20 22:39:40.765 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 160  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:36.919 2009  to  Fri Feb 20 22:39:40.807 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 161  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:40.765 2009  to  Fri Feb 20 22:39:40.872 2009   (  0.11) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 162  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:40.807 2009  to  Fri Feb 20 22:39:40.832 2009   (  0.02) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 163  FAILED    IIF        command.moveFocus                                             Fri Feb 20 22:39:42.218 2009  to  Fri Feb 20 22:39:42.725 2009   (  0.51) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 164  FAILED    PSF        command.setInstrumentOffsets                                  Fri Feb 20 22:39:42.274 2009  to  Fri Feb 20 22:39:42.645 2009   (  0.37) secs
                    right PSF SetInstrumentOffsets failed

 165  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:42.378 2009  to  Fri Feb 20 22:39:42.557 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 166  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Feb 20 22:39:42.326 2009  to  Fri Feb 20 22:39:42.608 2009   (  0.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 167  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:42.439 2009  to  Fri Feb 20 22:39:42.492 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 168  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 22:39:43.958 2009  to  Fri Feb 20 22:39:43.958 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 169  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 22:39:44.023 2009  to  Fri Feb 20 22:39:44.023 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 170  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Fri Feb 20 22:39:44.081 2009  to  Fri Feb 20 22:39:44.081 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror force adjustments complete

 171  FAILED    PMC        VxInterface.close                                             Fri Feb 20 22:44:26.876 2009  to  Fri Feb 20 22:44:26.876 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 172  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 22:44:26.846 2009  to  Fri Feb 20 22:44:26.846 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 173  FAILED    PMC        thermal.badReceive                                            Fri Feb 20 23:08:00.279 2009  to  Fri Feb 20 23:08:00.279 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 174  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:22.455 2009  to  Sat Feb 21 00:08:25.971 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 175  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:22.493 2009  to  Sat Feb 21 00:08:26.017 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 176  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 00:08:25.750 2009  to  Sat Feb 21 00:08:26.152 2009   (  0.40) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 177  FAILED    PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:26.017 2009  to  Sat Feb 21 00:08:26.051 2009   (  0.03) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 178  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:25.971 2009  to  Sat Feb 21 00:08:26.117 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 179  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:08:28.534 2009  to  Sat Feb 21 00:08:28.534 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 180  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:08:28.576 2009  to  Sat Feb 21 00:08:28.576 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 181  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Sat Feb 21 00:27:49.284 2009  to  Sat Feb 21 00:27:51.635 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 182  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Sat Feb 21 00:27:49.347 2009  to  Sat Feb 21 00:27:51.698 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started

 183  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 00:27:51.375 2009  to  Sat Feb 21 00:27:51.831 2009   (  0.46) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 184  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 01:17:28.822 2009  to  Sat Feb 21 02:08:05.466 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 185  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 01:17:29.090 2009  to  Sat Feb 21 01:17:29.090 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 186  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 01:17:40.219 2009  to  Sat Feb 21 01:18:03.605 2009   ( 23.39) secs
                    right PSF SetInstrumentOffsets failed

 187  FAILED    IIF        command.moveFocus                                             Sat Feb 21 01:17:40.170 2009  to  Sat Feb 21 01:18:03.694 2009   ( 23.52) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

 188  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 01:17:40.270 2009  to  Sat Feb 21 01:18:03.549 2009   ( 23.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 189  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 01:19:57.063 2009  to  Sat Feb 21 01:19:57.525 2009   (  0.46) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 190  FAILED    PSF        primaryMirror.command.adjustMirror                            Sat Feb 21 01:21:36.065 2009  to  Sat Feb 21 01:21:36.449 2009   (  0.38) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 191  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:17:46.605 2009  to  Sat Feb 21 02:29:45.782 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 192  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:17:46.873 2009  to  Sat Feb 21 02:17:46.873 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 193  FAILED    PMC        thermal.badReceive                                            Sat Feb 21 02:50:20.352 2009  to  Sat Feb 21 02:50:20.352 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 194  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:58:45.886 2009  to  Sat Feb 21 03:28:35.304 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 195  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 02:58:46.154 2009  to  Sat Feb 21 02:58:46.154 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 196  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 04:04:37.775 2009  to  Sat Feb 21 04:30:24.793 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 197  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 04:04:38.046 2009  to  Sat Feb 21 04:04:38.046 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 198  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:12:53.687 2009  to  Sat Feb 21 05:47:57.815 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 199  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:12:53.955 2009  to  Sat Feb 21 05:12:53.955 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 200  SEQERROR  PCS        telescope.command.startTracking                               Sat Feb 21 05:47:58.086 2009  to  Sat Feb 21 05:47:58.086 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 201  FAILED    IIF        command.moveFocus                                             Sat Feb 21 06:30:17.737 2009  to  Sat Feb 21 06:30:24.290 2009   (  6.55) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488356270833333e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.610000000000000e-01

 202  FAILED    PSF        command.setInstrumentOffsets                                  Sat Feb 21 06:30:17.806 2009  to  Sat Feb 21 06:30:24.191 2009   (  6.39) secs
                    right PSF SetInstrumentOffsets failed

 203  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Sat Feb 21 06:30:17.855 2009  to  Sat Feb 21 06:30:24.131 2009   (  6.28) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

**********************************************************
    Reporting period ending:   Sat Feb 21 07:26:53.215 2009
********************************************************************************************************