You are here: Foswiki>Software Web>TCSSWReportFile_090219 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Feb 19 2009 to Feb 20 2009
 
    Reporting period beginning:   Thu Feb 19 17:38:00.392 2009
    Reporting period ending:      Fri Feb 20 07:27:59.460 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = ecs.lights.command.enable.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.05   100.0 %        229        229                      
                                                                       0.01    0.02    0.01    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.21    0.32    0.12    1.20   100.0 %        680        680                      
                                                                       0.21    0.32    0.12    1.20
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.07    0.07    0.05    0.83   100.0 %        185        185                      
                                                                       0.07    0.07    0.05    0.83
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    5.25    6.26    2.19   60.58   100.0 %        700        700                      
                                                                       5.25    6.26    2.19   60.58
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.28    5.30    2.80    8.97   100.0 %         66         66                      
                                                                       1.28    5.30    2.80    8.97
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.30    4.62    2.02    8.03   100.0 %         66         66                      
                                                                       1.30    4.62    2.02    8.03
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   14.32   10.23    1.02   51.11   100.0 %         22         22                      
                                                                      14.32   10.23    1.02   51.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   26.53    8.37    2.04  126.26   100.0 %         22         22                      
                                                                      26.53    8.37    2.04  126.26
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   38.59   30.15    8.12  156.23    95.5 %         22         21                     1
                                                                      38.59   30.15    8.12  156.23
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    5.47    7.32    0.33   31.31    99.6 %        457        455          2           
                                                                       5.39    7.27    0.33   31.31
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    8.46    5.47    2.21   50.34   100.0 %         59         59                      
                                                                       8.46    5.47    2.21   50.34

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                            10

IIF Events of Interest

   1  FAILED    IIF        command.sendWavefront                                         Thu Feb 19 21:00:09.399 2009  to  Thu Feb 19 21:00:37.939 2009   ( 28.54) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

   2  FAILED    IIF        command.sendWavefront                                         Thu Feb 19 23:40:11.974 2009  to  Thu Feb 19 23:40:20.935 2009   (  8.96) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4297                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8593                      
                                                                                                   
     lights.command.enable. . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     6                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     105                      

ECS Events of Interest

   1  SXDXBOTH  ECS        lights.command.enable                                         Thu Feb 19 18:09:39.540 2009  to  Thu Feb 19 18:09:39.540 2009   (  0.00) secs
                    
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         27                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       4                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            34
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .       4                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      12                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       8                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             6
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                  8           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       2                      
     MCSPU.Logger.nEventsMissed . . . . . . . . . . . . . . . . . .                             1
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                515           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       4                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      62                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     517                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .     600                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     200                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 17:42:37.653 2009  to  Thu Feb 19 17:42:37.653 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 17:42:37.659 2009  to  Thu Feb 19 17:42:37.659 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Thu Feb 19 17:42:37.763 2009  to  Thu Feb 19 17:42:37.763 2009   (  0.00) secs
                    drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.283 2009  to  Thu Feb 19 17:42:38.283 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.283 2009  to  Thu Feb 19 17:42:38.283 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.284 2009  to  Thu Feb 19 17:42:38.284 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.284 2009  to  Thu Feb 19 17:42:38.284 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.285 2009  to  Thu Feb 19 17:42:38.285 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.285 2009  to  Thu Feb 19 17:42:38.285 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.286 2009  to  Thu Feb 19 17:42:38.286 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.286 2009  to  Thu Feb 19 17:42:38.286 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:40.648 2009  to  Thu Feb 19 17:42:40.648 2009   (  0.00) secs
                    EL bad poly no. 52: BAD Poly: EL = -6.357979e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:43.843 2009  to  Thu Feb 19 17:42:43.843 2009   (  0.00) secs
                    EL bad poly no. 100: BAD Poly: EL = -6.358330e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:46.720 2009  to  Thu Feb 19 17:42:46.720 2009   (  0.00) secs
                    EL bad poly no. 141: BAD Poly: EL = -6.358685e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:49.769 2009  to  Thu Feb 19 17:42:49.769 2009   (  0.00) secs
                    EL bad poly no. 188: BAD Poly: EL = -6.359039e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:52.871 2009  to  Thu Feb 19 17:42:52.871 2009   (  0.00) secs
                    EL bad poly no. 230: BAD Poly: EL = -6.359398e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:55.877 2009  to  Thu Feb 19 17:42:55.877 2009   (  0.00) secs
                    EL bad poly no. 260: BAD Poly: EL = -6.359746e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:58.912 2009  to  Thu Feb 19 17:42:58.912 2009   (  0.00) secs
                    EL bad poly no. 288: BAD Poly: EL = -6.360097e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:02.012 2009  to  Thu Feb 19 17:43:02.012 2009   (  0.00) secs
                    EL bad poly no. 316: BAD Poly: EL = -6.360454e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:05.059 2009  to  Thu Feb 19 17:43:05.059 2009   (  0.00) secs
                    EL bad poly no. 346: BAD Poly: EL = -6.360806e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:08.107 2009  to  Thu Feb 19 17:43:08.107 2009   (  0.00) secs
                    EL bad poly no. 388: BAD Poly: EL = -6.361156e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:11.171 2009  to  Thu Feb 19 17:43:11.171 2009   (  0.00) secs
                    EL bad poly no. 420: BAD Poly: EL = -6.361509e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:14.246 2009  to  Thu Feb 19 17:43:14.246 2009   (  0.00) secs
                    EL bad poly no. 447: BAD Poly: EL = -6.361862e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:17.361 2009  to  Thu Feb 19 17:43:17.361 2009   (  0.00) secs
                    EL bad poly no. 473: BAD Poly: EL = -6.362219e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:20.399 2009  to  Thu Feb 19 17:43:20.399 2009   (  0.00) secs
                    EL bad poly no. 506: BAD Poly: EL = -6.362567e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:23.433 2009  to  Thu Feb 19 17:43:23.433 2009   (  0.00) secs
                    EL bad poly no. 546: BAD Poly: EL = -6.362913e-01 rad. Too low.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:26.539 2009  to  Thu Feb 19 17:43:26.539 2009   (  0.00) secs
                    EL bad poly no. 585: BAD Poly: EL = -6.363268e-01 rad. Too low.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:29.613 2009  to  Thu Feb 19 17:43:29.613 2009   (  0.00) secs
                    EL bad poly no. 613: BAD Poly: EL = -6.363618e-01 rad. Too low.

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:32.663 2009  to  Thu Feb 19 17:43:32.663 2009   (  0.00) secs
                    EL bad poly no. 639: BAD Poly: EL = -6.363966e-01 rad. Too low.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:35.734 2009  to  Thu Feb 19 17:43:35.734 2009   (  0.00) secs
                    EL bad poly no. 665: BAD Poly: EL = -6.364315e-01 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:38.760 2009  to  Thu Feb 19 17:43:38.760 2009   (  0.00) secs
                    EL bad poly no. 709: BAD Poly: EL = -6.364658e-01 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:41.825 2009  to  Thu Feb 19 17:43:41.825 2009   (  0.00) secs
                    EL bad poly no. 753: BAD Poly: EL = -6.365006e-01 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:44.905 2009  to  Thu Feb 19 17:43:44.905 2009   (  0.00) secs
                    EL bad poly no. 799: BAD Poly: EL = -6.365355e-01 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:47.954 2009  to  Thu Feb 19 17:43:47.954 2009   (  0.00) secs
                    EL bad poly no. 842: BAD Poly: EL = -6.365699e-01 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:51.072 2009  to  Thu Feb 19 17:43:51.072 2009   (  0.00) secs
                    EL bad poly no. 888: BAD Poly: EL = -6.366051e-01 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:54.110 2009  to  Thu Feb 19 17:43:54.110 2009   (  0.00) secs
                    EL bad poly no. 923: BAD Poly: EL = -6.366394e-01 rad. Too low.

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 18:08:45.738 2009  to  Thu Feb 19 18:08:45.738 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.02    0.01    0.01    0.20   100.0 %        185        185                      
                                                                       0.02    0.01    0.01    0.20
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.10    0.06    0.20   100.0 %        680        680                      
                                                                       0.02    0.10    0.06    0.20
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.04    0.04    0.04   100.0 %          1          1                      
                                                                       0.00    0.04    0.04    0.04
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.19    0.20    0.01    0.64   100.0 %         66         66                      
                                                                       0.19    0.20    0.01    0.64
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.00    0.01    0.01    0.02   100.0 %          4          4                      
                                                                       0.00    0.01    0.01    0.02
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.18    0.22    0.01    0.84   100.0 %         31         31                      
                                                                       0.18    0.22    0.01    0.84
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.31    0.45    0.00    0.77   100.0 %         31         31                      
                                                                       0.13    0.64    0.52    0.77

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  2           
     weather.telemetryError . . . . . . . . . . . . . . . . . . . .                  2           
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  2           

PCS Events of Interest

   1  SHUTDOWN  PCS        shutdown                                                      Thu Feb 19 18:08:45.193 2009  to  Thu Feb 19 18:08:45.193 2009   (  0.00) secs
                    PCS subsystem shut down - PCS Version 3.30b

   2  STARTUP   PCS        startup                                                       Thu Feb 19 18:08:52.601 2009  to  Thu Feb 19 18:08:52.601 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.30b

   3  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 18:08:53.653 2009  to  Thu Feb 19 18:08:53.653 2009   (  0.00) secs
                    PCS Guider telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   4  FAILED    PCS        weather.telemetryError                                        Thu Feb 19 18:08:53.745 2009  to  Thu Feb 19 18:08:53.745 2009   (  0.00) secs
                    PCS Weather telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   5  FAILED    PCS        telescope.telemetryError                                      Thu Feb 19 18:08:53.951 2009  to  Thu Feb 19 18:08:53.951 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

   6  FAILED    PCS        weather.telemetryError                                        Thu Feb 19 18:08:54.051 2009  to  Thu Feb 19 18:08:54.051 2009   (  0.00) secs
                    PCS Weather telemetry error: No telemetry since telemeter registration failed.

   7  FAILED    PCS        telescope.telemetryError                                      Thu Feb 19 18:15:07.665 2009  to  Thu Feb 19 18:15:07.665 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   8  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 18:15:07.699 2009  to  Thu Feb 19 18:53:06.451 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   9  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 18:15:07.968 2009  to  Thu Feb 19 18:15:07.968 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  10  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 19:11:23.125 2009  to  Thu Feb 19 19:11:23.125 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  11  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 21:31:27.396 2009  to  Thu Feb 19 21:42:07.799 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 21:31:27.663 2009  to  Thu Feb 19 21:31:27.663 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 23:06:33.898 2009  to  Thu Feb 19 23:11:35.859 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 23:06:34.165 2009  to  Thu Feb 19 23:06:34.165 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 01:51:19.461 2009  to  Fri Feb 20 02:06:00.577 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 01:51:19.728 2009  to  Fri Feb 20 01:51:19.728 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  17  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:03:13.188 2009  to  Fri Feb 20 03:27:43.238 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  18  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:03:13.458 2009  to  Fri Feb 20 03:03:13.458 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  19  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:27:43.238 2009  to  Fri Feb 20 03:35:05.671 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  20  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:27:43.519 2009  to  Fri Feb 20 03:27:43.519 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  21  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:10:11.807 2009  to  Fri Feb 20 04:30:19.167 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  22  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:10:12.127 2009  to  Fri Feb 20 04:10:12.127 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  23  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:56:05.215 2009  to  Fri Feb 20 05:36:34.599 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  24  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:56:05.485 2009  to  Fri Feb 20 04:56:05.485 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  25  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 05:36:34.599 2009  to  Fri Feb 20 06:10:40.970 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  26  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 05:36:34.866 2009  to  Fri Feb 20 05:36:34.866 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.51    3.34    0.00   10.04   100.0 %        228        228                      
                                                                       1.50    3.35    2.02   10.04
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    1.47    3.18    2.02    5.05   100.0 %          7          7                      
                                                                       1.47    3.18    2.02    5.05
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.01    2.03    2.02    2.05   100.0 %          6          6                      
                                                                       0.01    2.03    2.02    2.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    6.34    6.29    0.00   68.14    99.3 %       1251       1242          9           
                                                                       6.31    6.28    2.02   68.14

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           391
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           390
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       6                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       7                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           292
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            40
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 41           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 41           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      41                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     228                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.connect.failed . . . . . . . . . . . . . . . . . .                  1           
     thermal.badSend. . . . . . . . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:16:23.139 2009  to  Thu Feb 19 18:16:30.187 2009   (  7.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:16:24.035 2009  to  Thu Feb 19 18:16:30.067 2009   (  6.03) secs
                    right PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        VxInterface.close                                             Thu Feb 19 18:40:32.885 2009  to  Thu Feb 19 18:40:32.885 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 18:40:32.869 2009  to  Thu Feb 19 18:40:32.869 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:53:51.303 2009  to  Thu Feb 19 18:54:17.370 2009   ( 26.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 19:19:23.199 2009  to  Thu Feb 19 19:19:23.199 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   7  FAILED    PMC        VxInterface.close                                             Thu Feb 19 19:19:23.221 2009  to  Thu Feb 19 19:19:23.221 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   8  SEQERROR  PMC        actuator.command.changeOffsets.all                            Thu Feb 19 19:26:59.437 2009  to  Thu Feb 19 19:27:01.112 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Actuator ChangeAllOffsets Command Started

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:08.544 2009  to  Thu Feb 19 19:27:09.226 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  SEQERROR  PMC        actuator.command.changeOffsets.all                            Thu Feb 19 19:27:09.145 2009  to  Thu Feb 19 19:27:09.145 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Actuator ChangeAllOffsets Command Complete

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:09.226 2009  to  Thu Feb 19 19:27:09.243 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  12  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:17.583 2009  to  Thu Feb 19 19:27:17.583 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  13  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 19:27:28.245 2009  to  Thu Feb 19 19:27:28.245 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  14  FAILED    PMC        VxInterface.close                                             Thu Feb 19 19:27:28.269 2009  to  Thu Feb 19 19:27:28.269 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  15  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:05:33.101 2009  to  Thu Feb 19 20:05:33.101 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  16  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:05:33.117 2009  to  Thu Feb 19 20:05:33.117 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  17  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:10:20.277 2009  to  Thu Feb 19 20:10:20.277 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  18  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:10:20.258 2009  to  Thu Feb 19 20:10:20.258 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  19  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:45:33.533 2009  to  Thu Feb 19 20:45:33.533 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:45:33.517 2009  to  Thu Feb 19 20:45:33.517 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

  21  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 19 20:52:53.309 2009  to  Thu Feb 19 20:52:53.309 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  22  FAILED    PMC        thermal.badReceive                                            Thu Feb 19 20:52:53.363 2009  to  Thu Feb 19 20:52:53.363 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  23  FAILED    PMC        VxInterface.packetReadError                                   Thu Feb 19 20:52:53.344 2009  to  Thu Feb 19 20:52:53.344 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 21:00:12.629 2009  to  Thu Feb 19 21:00:37.693 2009   ( 25.06) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:08:57.457 2009  to  Thu Feb 19 21:08:57.457 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:08:57.430 2009  to  Thu Feb 19 21:08:57.430 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:15:04.665 2009  to  Thu Feb 19 21:15:04.665 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:15:04.650 2009  to  Thu Feb 19 21:15:04.650 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:38:04.741 2009  to  Thu Feb 19 21:38:04.741 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  30  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:38:04.767 2009  to  Thu Feb 19 21:38:04.767 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:56:55.617 2009  to  Thu Feb 19 21:56:55.617 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:56:55.598 2009  to  Thu Feb 19 21:56:55.598 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  33  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:05:02.548 2009  to  Thu Feb 19 22:05:02.548 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:05:02.525 2009  to  Thu Feb 19 22:05:02.525 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:24:14.548 2009  to  Thu Feb 19 22:24:14.548 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  36  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:24:14.522 2009  to  Thu Feb 19 22:24:14.522 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  37  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 22:32:50.343 2009  to  Thu Feb 19 22:32:52.367 2009   (  2.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:40:53.204 2009  to  Thu Feb 19 22:40:53.204 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:40:53.180 2009  to  Thu Feb 19 22:40:53.180 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:56:23.782 2009  to  Thu Feb 19 22:56:23.782 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:56:23.762 2009  to  Thu Feb 19 22:56:23.762 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  42  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:12:01.006 2009  to  Thu Feb 19 23:12:01.006 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:12:00.988 2009  to  Thu Feb 19 23:12:00.988 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:16:25.000 2009  to  Thu Feb 19 23:16:25.000 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:16:24.981 2009  to  Thu Feb 19 23:16:24.981 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  46  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:16:34.214 2009  to  Thu Feb 19 23:16:34.214 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:16:34.180 2009  to  Thu Feb 19 23:16:34.180 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  48  FAILED    PMC        VxInterface.connect.failed                                    Thu Feb 19 23:21:13.083 2009  to  Thu Feb 19 23:21:13.083 2009   (  0.00) secs
                    right PMC Thermal failed to connect to IP 10.144.0.205 port 50009

  49  FAILED    PMC        thermal.badSend                                               Thu Feb 19 23:21:14.107 2009  to  Thu Feb 19 23:21:14.107 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad send to thermal computer, error is pmc.vxWorks.connection.failed

  50  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:28:51.756 2009  to  Thu Feb 19 23:28:51.756 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:28:51.735 2009  to  Thu Feb 19 23:28:51.735 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

  52  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 23:40:14.718 2009  to  Thu Feb 19 23:40:20.749 2009   (  6.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PMC        VxInterface.close                                             Fri Feb 20 00:13:43.245 2009  to  Fri Feb 20 00:13:43.245 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 00:13:43.226 2009  to  Fri Feb 20 00:13:43.226 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  55  FAILED    PMC        VxInterface.close                                             Fri Feb 20 00:15:33.530 2009  to  Fri Feb 20 00:15:33.530 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  56  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 00:15:33.509 2009  to  Fri Feb 20 00:15:33.509 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  57  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:04:54.278 2009  to  Fri Feb 20 01:04:54.278 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  58  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:04:54.258 2009  to  Fri Feb 20 01:04:54.258 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  59  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:50:22.410 2009  to  Fri Feb 20 01:50:22.410 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:50:22.388 2009  to  Fri Feb 20 01:50:22.388 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  61  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 01:51:21.837 2009  to  Fri Feb 20 01:51:26.183 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  62  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:51:22.199 2009  to  Fri Feb 20 01:51:22.199 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  63  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:51:22.179 2009  to  Fri Feb 20 01:51:22.179 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  64  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:51:22.556 2009  to  Fri Feb 20 01:51:22.556 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  65  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:51:22.534 2009  to  Fri Feb 20 01:51:22.534 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  66  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 01:51:35.909 2009  to  Fri Feb 20 01:51:35.909 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  67  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:52:45.787 2009  to  Fri Feb 20 01:52:45.787 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  68  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:52:45.767 2009  to  Fri Feb 20 01:52:45.767 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  69  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 06:50:31.540 2009  to  Fri Feb 20 06:50:33.571 2009   (  2.03) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  70  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 06:50:33.664 2009  to  Fri Feb 20 06:50:35.719 2009   (  2.05) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    5.47    7.18    0.24   31.16    99.6 %        457        455          2           
                                                                       5.39    7.13    0.24   31.16
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.07   100.0 %         44         44                      
                                                                       0.01    0.03    0.02    0.07
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.56    6.11    2.14   60.46   100.0 %        759        759                      
                                                                       5.56    6.11    2.14   60.46
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    5.47    7.24    0.27   31.21    99.6 %        457        455          2           
                                                                       5.39    7.19    0.27   31.21
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    5.58    7.25    0.00   31.05    99.4 %        473        470          3           
                                                                       5.51    7.22    0.16   31.05
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    6.34    6.37    0.00   68.21    99.3 %       1251       1242          9           
                                                                       6.31    6.36    2.07   68.21
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.02    2.10    2.08    2.14   100.0 %          6          6                      
                                                                       0.02    2.10    2.08    2.14
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    1.48    3.27    2.10    5.20   100.0 %          7          7                      
                                                                       1.48    3.27    2.10    5.20
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.07    0.03    0.20   100.0 %        388        388                      
                                                                       0.03    0.07    0.03    0.20
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   18.23   14.53    4.36   51.41    16.7 %          6          1          5           
                                                                       0.00   51.41   51.41   51.41
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   15.60   41.24   30.21   52.27   100.0 %          2          2                      
                                                                      15.60   41.24   30.21   52.27
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.56    6.05    2.10   60.39   100.0 %        759        759                      
                                                                       5.56    6.05    2.10   60.39
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.03    0.02    0.06   100.0 %         15         15                      
                                                                       0.01    0.03    0.02    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.03    0.01    0.09   100.0 %        472        472                      
                                                                       0.01    0.03    0.01    0.09

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .               1336           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 18:16:19.870 2009  to  Thu Feb 19 18:16:30.116 2009   ( 10.25) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 18:16:20.932 2009  to  Thu Feb 19 18:16:30.255 2009   (  9.32) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:16:23.094 2009  to  Thu Feb 19 18:16:30.234 2009   (  7.14) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:16:24.009 2009  to  Thu Feb 19 18:16:30.096 2009   (  6.09) secs
                    right PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.541 2009  to  Thu Feb 19 18:18:04.541 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0847321e-03 -3.8962066e-04 -1.0806322e-03 1.8212128e-01 -4.7065735e-02 -4.2832851e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.760 2009  to  Thu Feb 19 18:18:04.760 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0847321e-03 -3.8962066e-04 -1.0806322e-03 1.8212128e-01 -4.7065735e-02 -4.2832851e-02

   7  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.979 2009  to  Thu Feb 19 18:18:04.979 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9241571e-03 -7.6755881e-05 -7.0124865e-04 1.8836784e-01 -2.4192810e-02 -6.4324379e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:05.202 2009  to  Thu Feb 19 18:18:05.202 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9241571e-03 -7.6755881e-05 -7.0124865e-04 1.8836784e-01 -2.4192810e-02 -6.4324379e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.033 2009  to  Thu Feb 19 18:18:06.033 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2702217e-03 -8.4683299e-05 -8.8799000e-04 1.6564560e-01 -2.9518127e-02 -5.3744793e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.252 2009  to  Thu Feb 19 18:18:06.252 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.493 2009  to  Thu Feb 19 18:18:06.493 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.712 2009  to  Thu Feb 19 18:18:06.712 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  13  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.340 2009  to  Thu Feb 19 18:18:07.340 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.560 2009  to  Thu Feb 19 18:18:07.560 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  15  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.780 2009  to  Thu Feb 19 18:18:07.780 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  16  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.001 2009  to  Thu Feb 19 18:18:08.001 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  17  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.220 2009  to  Thu Feb 19 18:18:08.220 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  18  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.443 2009  to  Thu Feb 19 18:18:08.443 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  19  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.661 2009  to  Thu Feb 19 18:18:08.661 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  20  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.878 2009  to  Thu Feb 19 18:18:08.878 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.5841722e-03 -7.8916550e-05 -1.0682344e-03 1.6595650e-01 -1.9329071e-02 -8.5113585e-02

  21  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.099 2009  to  Thu Feb 19 18:18:09.099 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.5841722e-03 -7.8916550e-05 -1.0682344e-03 1.6595650e-01 -1.9329071e-02 -8.5113585e-02

  22  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.334 2009  to  Thu Feb 19 18:18:09.334 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  23  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.551 2009  to  Thu Feb 19 18:18:09.551 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  24  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.176 2009  to  Thu Feb 19 18:18:10.176 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  25  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.409 2009  to  Thu Feb 19 18:18:10.409 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  26  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.631 2009  to  Thu Feb 19 18:18:10.631 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  27  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.257 2009  to  Thu Feb 19 18:18:11.257 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.474 2009  to  Thu Feb 19 18:18:11.474 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.694 2009  to  Thu Feb 19 18:18:11.694 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2702217e-03 -8.4683299e-05 -8.8799000e-04 1.6564560e-01 -2.9518127e-02 -5.3744793e-02

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:53:51.277 2009  to  Thu Feb 19 18:54:17.403 2009   ( 26.13) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  31  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:26:59.034 2009  to  Thu Feb 19 19:27:00.694 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  32  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:27:00.694 2009  to  Thu Feb 19 19:27:09.310 2009   (  8.62) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:08.512 2009  to  Thu Feb 19 19:27:09.180 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  34  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:09.180 2009  to  Thu Feb 19 19:27:09.278 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  35  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:17.612 2009  to  Thu Feb 19 19:27:17.612 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  36  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:27:17.640 2009  to  Thu Feb 19 19:27:17.640 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  37  FAILED    PSF        command.applyZernikes                                         Thu Feb 19 21:00:09.479 2009  to  Thu Feb 19 21:00:37.788 2009   ( 28.31) secs
                    right PSF ApplyZernikes failed

  38  FAILED    PSF        command.setZernikes                                           Thu Feb 19 21:00:09.454 2009  to  Thu Feb 19 21:00:37.816 2009   ( 28.36) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  39  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 21:00:09.557 2009  to  Thu Feb 19 21:00:37.758 2009   ( 28.20) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 21:00:12.585 2009  to  Thu Feb 19 21:00:37.722 2009   ( 25.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  41  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 22:32:48.099 2009  to  Thu Feb 19 22:32:52.455 2009   (  4.36) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 22:32:50.306 2009  to  Thu Feb 19 22:32:52.400 2009   (  2.09) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  FAILED    PSF        command.applyZernikes                                         Thu Feb 19 23:40:12.041 2009  to  Thu Feb 19 23:40:20.851 2009   (  8.81) secs
                    right PSF ApplyZernikes failed

  44  FAILED    PSF        command.setZernikes                                           Thu Feb 19 23:40:12.009 2009  to  Thu Feb 19 23:40:20.877 2009   (  8.87) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

  45  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 23:40:12.126 2009  to  Thu Feb 19 23:40:20.814 2009   (  8.69) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  46  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 23:40:14.682 2009  to  Thu Feb 19 23:40:20.785 2009   (  6.10) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  47  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 01:51:21.799 2009  to  Fri Feb 20 01:51:26.122 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  48  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 01:51:35.952 2009  to  Fri Feb 20 01:51:35.952 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  49  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 06:50:28.315 2009  to  Fri Feb 20 06:50:35.786 2009   (  7.47) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  50  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 06:50:29.335 2009  to  Fri Feb 20 06:50:33.692 2009   (  4.36) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 06:50:31.497 2009  to  Fri Feb 20 06:50:33.636 2009   (  2.14) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 06:50:33.600 2009  to  Fri Feb 20 06:50:35.756 2009   (  2.16) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 17:42:37.653 2009  to  Thu Feb 19 17:42:37.653 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 17:42:37.659 2009  to  Thu Feb 19 17:42:37.659 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Thu Feb 19 17:42:37.763 2009  to  Thu Feb 19 17:42:37.763 2009   (  0.00) secs
                    drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.283 2009  to  Thu Feb 19 17:42:38.283 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.283 2009  to  Thu Feb 19 17:42:38.283 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.284 2009  to  Thu Feb 19 17:42:38.284 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.284 2009  to  Thu Feb 19 17:42:38.284 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.285 2009  to  Thu Feb 19 17:42:38.285 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.285 2009  to  Thu Feb 19 17:42:38.285 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.286 2009  to  Thu Feb 19 17:42:38.286 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Thu Feb 19 17:42:38.286 2009  to  Thu Feb 19 17:42:38.286 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:40.648 2009  to  Thu Feb 19 17:42:40.648 2009   (  0.00) secs
                    EL bad poly no. 52: BAD Poly: EL = -6.357979e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:43.843 2009  to  Thu Feb 19 17:42:43.843 2009   (  0.00) secs
                    EL bad poly no. 100: BAD Poly: EL = -6.358330e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:46.720 2009  to  Thu Feb 19 17:42:46.720 2009   (  0.00) secs
                    EL bad poly no. 141: BAD Poly: EL = -6.358685e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:49.769 2009  to  Thu Feb 19 17:42:49.769 2009   (  0.00) secs
                    EL bad poly no. 188: BAD Poly: EL = -6.359039e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:52.871 2009  to  Thu Feb 19 17:42:52.871 2009   (  0.00) secs
                    EL bad poly no. 230: BAD Poly: EL = -6.359398e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:55.877 2009  to  Thu Feb 19 17:42:55.877 2009   (  0.00) secs
                    EL bad poly no. 260: BAD Poly: EL = -6.359746e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:42:58.912 2009  to  Thu Feb 19 17:42:58.912 2009   (  0.00) secs
                    EL bad poly no. 288: BAD Poly: EL = -6.360097e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:02.012 2009  to  Thu Feb 19 17:43:02.012 2009   (  0.00) secs
                    EL bad poly no. 316: BAD Poly: EL = -6.360454e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:05.059 2009  to  Thu Feb 19 17:43:05.059 2009   (  0.00) secs
                    EL bad poly no. 346: BAD Poly: EL = -6.360806e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:08.107 2009  to  Thu Feb 19 17:43:08.107 2009   (  0.00) secs
                    EL bad poly no. 388: BAD Poly: EL = -6.361156e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:11.171 2009  to  Thu Feb 19 17:43:11.171 2009   (  0.00) secs
                    EL bad poly no. 420: BAD Poly: EL = -6.361509e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:14.246 2009  to  Thu Feb 19 17:43:14.246 2009   (  0.00) secs
                    EL bad poly no. 447: BAD Poly: EL = -6.361862e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:17.361 2009  to  Thu Feb 19 17:43:17.361 2009   (  0.00) secs
                    EL bad poly no. 473: BAD Poly: EL = -6.362219e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:20.399 2009  to  Thu Feb 19 17:43:20.399 2009   (  0.00) secs
                    EL bad poly no. 506: BAD Poly: EL = -6.362567e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:23.433 2009  to  Thu Feb 19 17:43:23.433 2009   (  0.00) secs
                    EL bad poly no. 546: BAD Poly: EL = -6.362913e-01 rad. Too low.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:26.539 2009  to  Thu Feb 19 17:43:26.539 2009   (  0.00) secs
                    EL bad poly no. 585: BAD Poly: EL = -6.363268e-01 rad. Too low.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:29.613 2009  to  Thu Feb 19 17:43:29.613 2009   (  0.00) secs
                    EL bad poly no. 613: BAD Poly: EL = -6.363618e-01 rad. Too low.

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:32.663 2009  to  Thu Feb 19 17:43:32.663 2009   (  0.00) secs
                    EL bad poly no. 639: BAD Poly: EL = -6.363966e-01 rad. Too low.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:35.734 2009  to  Thu Feb 19 17:43:35.734 2009   (  0.00) secs
                    EL bad poly no. 665: BAD Poly: EL = -6.364315e-01 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:38.760 2009  to  Thu Feb 19 17:43:38.760 2009   (  0.00) secs
                    EL bad poly no. 709: BAD Poly: EL = -6.364658e-01 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:41.825 2009  to  Thu Feb 19 17:43:41.825 2009   (  0.00) secs
                    EL bad poly no. 753: BAD Poly: EL = -6.365006e-01 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:44.905 2009  to  Thu Feb 19 17:43:44.905 2009   (  0.00) secs
                    EL bad poly no. 799: BAD Poly: EL = -6.365355e-01 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:47.954 2009  to  Thu Feb 19 17:43:47.954 2009   (  0.00) secs
                    EL bad poly no. 842: BAD Poly: EL = -6.365699e-01 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:51.072 2009  to  Thu Feb 19 17:43:51.072 2009   (  0.00) secs
                    EL bad poly no. 888: BAD Poly: EL = -6.366051e-01 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Feb 19 17:43:54.110 2009  to  Thu Feb 19 17:43:54.110 2009   (  0.00) secs
                    EL bad poly no. 923: BAD Poly: EL = -6.366394e-01 rad. Too low.

  37  SHUTDOWN  PCS        shutdown                                                      Thu Feb 19 18:08:45.193 2009  to  Thu Feb 19 18:08:45.193 2009   (  0.00) secs
                    PCS subsystem shut down - PCS Version 3.30b

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Thu Feb 19 18:08:45.738 2009  to  Thu Feb 19 18:08:45.738 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  39  STARTUP   PCS        startup                                                       Thu Feb 19 18:08:52.601 2009  to  Thu Feb 19 18:08:52.601 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.30b

  40  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 18:08:53.653 2009  to  Thu Feb 19 18:08:53.653 2009   (  0.00) secs
                    PCS Guider telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

  41  FAILED    PCS        weather.telemetryError                                        Thu Feb 19 18:08:53.745 2009  to  Thu Feb 19 18:08:53.745 2009   (  0.00) secs
                    PCS Weather telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

  42  FAILED    PCS        telescope.telemetryError                                      Thu Feb 19 18:08:53.951 2009  to  Thu Feb 19 18:08:53.951 2009   (  0.00) secs
                    PCS Telescope telemetry error: 2002: Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2)

  43  FAILED    PCS        weather.telemetryError                                        Thu Feb 19 18:08:54.051 2009  to  Thu Feb 19 18:08:54.051 2009   (  0.00) secs
                    PCS Weather telemetry error: No telemetry since telemeter registration failed.

  44  SXDXBOTH  ECS        lights.command.enable                                         Thu Feb 19 18:09:39.540 2009  to  Thu Feb 19 18:09:39.540 2009   (  0.00) secs
                    

  45  FAILED    PCS        telescope.telemetryError                                      Thu Feb 19 18:15:07.665 2009  to  Thu Feb 19 18:15:07.665 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

  46  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 18:15:07.699 2009  to  Thu Feb 19 18:53:06.451 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  47  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 18:15:07.968 2009  to  Thu Feb 19 18:15:07.968 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  48  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 18:16:19.870 2009  to  Thu Feb 19 18:16:30.116 2009   ( 10.25) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 18:16:20.932 2009  to  Thu Feb 19 18:16:30.255 2009   (  9.32) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  50  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:16:23.094 2009  to  Thu Feb 19 18:16:30.234 2009   (  7.14) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:16:23.139 2009  to  Thu Feb 19 18:16:30.187 2009   (  7.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:16:24.035 2009  to  Thu Feb 19 18:16:30.067 2009   (  6.03) secs
                    right PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:16:24.009 2009  to  Thu Feb 19 18:16:30.096 2009   (  6.09) secs
                    right PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  54  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.541 2009  to  Thu Feb 19 18:18:04.541 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0847321e-03 -3.8962066e-04 -1.0806322e-03 1.8212128e-01 -4.7065735e-02 -4.2832851e-02

  55  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.760 2009  to  Thu Feb 19 18:18:04.760 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.0847321e-03 -3.8962066e-04 -1.0806322e-03 1.8212128e-01 -4.7065735e-02 -4.2832851e-02

  56  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:04.979 2009  to  Thu Feb 19 18:18:04.979 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9241571e-03 -7.6755881e-05 -7.0124865e-04 1.8836784e-01 -2.4192810e-02 -6.4324379e-02

  57  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:05.202 2009  to  Thu Feb 19 18:18:05.202 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9241571e-03 -7.6755881e-05 -7.0124865e-04 1.8836784e-01 -2.4192810e-02 -6.4324379e-02

  58  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.033 2009  to  Thu Feb 19 18:18:06.033 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2702217e-03 -8.4683299e-05 -8.8799000e-04 1.6564560e-01 -2.9518127e-02 -5.3744793e-02

  59  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.252 2009  to  Thu Feb 19 18:18:06.252 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  60  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.493 2009  to  Thu Feb 19 18:18:06.493 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  61  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:06.712 2009  to  Thu Feb 19 18:18:06.712 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  62  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.340 2009  to  Thu Feb 19 18:18:07.340 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  63  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.560 2009  to  Thu Feb 19 18:18:07.560 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  64  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:07.780 2009  to  Thu Feb 19 18:18:07.780 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  65  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.001 2009  to  Thu Feb 19 18:18:08.001 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  66  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.220 2009  to  Thu Feb 19 18:18:08.220 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  67  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.443 2009  to  Thu Feb 19 18:18:08.443 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  68  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.661 2009  to  Thu Feb 19 18:18:08.661 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  69  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:08.878 2009  to  Thu Feb 19 18:18:08.878 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.5841722e-03 -7.8916550e-05 -1.0682344e-03 1.6595650e-01 -1.9329071e-02 -8.5113585e-02

  70  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.099 2009  to  Thu Feb 19 18:18:09.099 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.5841722e-03 -7.8916550e-05 -1.0682344e-03 1.6595650e-01 -1.9329071e-02 -8.5113585e-02

  71  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.334 2009  to  Thu Feb 19 18:18:09.334 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  72  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:09.551 2009  to  Thu Feb 19 18:18:09.551 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.7458200e-03 2.1649897e-04 -8.8649988e-04 1.7252350e-01 -4.1069031e-02 -7.4818611e-02

  73  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.176 2009  to  Thu Feb 19 18:18:10.176 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  74  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.409 2009  to  Thu Feb 19 18:18:10.409 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  75  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:10.631 2009  to  Thu Feb 19 18:18:10.631 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.9062757e-03 -9.6365809e-05 -1.2658834e-03 1.6627693e-01 -6.3945770e-02 -5.3327084e-02

  76  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.257 2009  to  Thu Feb 19 18:18:11.257 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  77  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.474 2009  to  Thu Feb 19 18:18:11.474 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.1085739e-03 -3.8009882e-04 -1.0697842e-03 1.5907860e-01 -7.7781677e-03 -6.4039767e-02

  78  FAILED    PSF        primaryMirror.positionError                                   Thu Feb 19 18:18:11.694 2009  to  Thu Feb 19 18:18:11.694 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -2.2702217e-03 -8.4683299e-05 -8.8799000e-04 1.6564560e-01 -2.9518127e-02 -5.3744793e-02

  79  FAILED    PMC        VxInterface.close                                             Thu Feb 19 18:40:32.885 2009  to  Thu Feb 19 18:40:32.885 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  80  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 18:40:32.869 2009  to  Thu Feb 19 18:40:32.869 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  81  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 18:53:51.303 2009  to  Thu Feb 19 18:54:17.370 2009   ( 26.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  82  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 18:53:51.277 2009  to  Thu Feb 19 18:54:17.403 2009   ( 26.13) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 19:11:23.125 2009  to  Thu Feb 19 19:11:23.125 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  84  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 19:19:23.199 2009  to  Thu Feb 19 19:19:23.199 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  85  FAILED    PMC        VxInterface.close                                             Thu Feb 19 19:19:23.221 2009  to  Thu Feb 19 19:19:23.221 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  86  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:26:59.034 2009  to  Thu Feb 19 19:27:00.694 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF adjusting primary mirror forces

  87  SEQERROR  PMC        actuator.command.changeOffsets.all                            Thu Feb 19 19:26:59.437 2009  to  Thu Feb 19 19:27:01.112 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Actuator ChangeAllOffsets Command Started

  88  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:27:00.694 2009  to  Thu Feb 19 19:27:09.310 2009   (  8.62) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  89  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:08.544 2009  to  Thu Feb 19 19:27:09.226 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  90  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:08.512 2009  to  Thu Feb 19 19:27:09.180 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  91  SEQERROR  PMC        actuator.command.changeOffsets.all                            Thu Feb 19 19:27:09.145 2009  to  Thu Feb 19 19:27:09.145 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Actuator ChangeAllOffsets Command Complete

  92  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:09.226 2009  to  Thu Feb 19 19:27:09.243 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  93  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:09.180 2009  to  Thu Feb 19 19:27:09.278 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  94  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 19:27:17.583 2009  to  Thu Feb 19 19:27:17.583 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  95  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 19:27:17.612 2009  to  Thu Feb 19 19:27:17.612 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  96  SEQERROR  PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 19:27:17.640 2009  to  Thu Feb 19 19:27:17.640 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror force adjustments complete

  97  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 19:27:28.245 2009  to  Thu Feb 19 19:27:28.245 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  98  FAILED    PMC        VxInterface.close                                             Thu Feb 19 19:27:28.269 2009  to  Thu Feb 19 19:27:28.269 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  99  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:05:33.101 2009  to  Thu Feb 19 20:05:33.101 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 100  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:05:33.117 2009  to  Thu Feb 19 20:05:33.117 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 101  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:10:20.277 2009  to  Thu Feb 19 20:10:20.277 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:10:20.258 2009  to  Thu Feb 19 20:10:20.258 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 103  FAILED    PMC        VxInterface.close                                             Thu Feb 19 20:45:33.533 2009  to  Thu Feb 19 20:45:33.533 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

 104  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 20:45:33.517 2009  to  Thu Feb 19 20:45:33.517 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

 105  FAILED    PMC        VxInterface.selectTimeout                                     Thu Feb 19 20:52:53.309 2009  to  Thu Feb 19 20:52:53.309 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 106  FAILED    PMC        thermal.badReceive                                            Thu Feb 19 20:52:53.363 2009  to  Thu Feb 19 20:52:53.363 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 107  FAILED    PMC        VxInterface.packetReadError                                   Thu Feb 19 20:52:53.344 2009  to  Thu Feb 19 20:52:53.344 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 108  FAILED    IIF        command.sendWavefront                                         Thu Feb 19 21:00:09.399 2009  to  Thu Feb 19 21:00:37.939 2009   ( 28.54) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 109  FAILED    PSF        command.applyZernikes                                         Thu Feb 19 21:00:09.479 2009  to  Thu Feb 19 21:00:37.788 2009   ( 28.31) secs
                    right PSF ApplyZernikes failed

 110  FAILED    PSF        command.setZernikes                                           Thu Feb 19 21:00:09.454 2009  to  Thu Feb 19 21:00:37.816 2009   ( 28.36) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 111  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 21:00:09.557 2009  to  Thu Feb 19 21:00:37.758 2009   ( 28.20) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 112  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 21:00:12.585 2009  to  Thu Feb 19 21:00:37.722 2009   ( 25.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 113  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 21:00:12.629 2009  to  Thu Feb 19 21:00:37.693 2009   ( 25.06) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 114  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:08:57.457 2009  to  Thu Feb 19 21:08:57.457 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 115  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:08:57.430 2009  to  Thu Feb 19 21:08:57.430 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 116  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:15:04.665 2009  to  Thu Feb 19 21:15:04.665 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 117  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:15:04.650 2009  to  Thu Feb 19 21:15:04.650 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 118  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 21:31:27.396 2009  to  Thu Feb 19 21:42:07.799 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 119  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 21:31:27.663 2009  to  Thu Feb 19 21:31:27.663 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 120  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:38:04.741 2009  to  Thu Feb 19 21:38:04.741 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 121  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:38:04.767 2009  to  Thu Feb 19 21:38:04.767 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 122  FAILED    PMC        VxInterface.close                                             Thu Feb 19 21:56:55.617 2009  to  Thu Feb 19 21:56:55.617 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 123  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 21:56:55.598 2009  to  Thu Feb 19 21:56:55.598 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 124  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:05:02.548 2009  to  Thu Feb 19 22:05:02.548 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 125  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:05:02.525 2009  to  Thu Feb 19 22:05:02.525 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 126  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:24:14.548 2009  to  Thu Feb 19 22:24:14.548 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 127  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:24:14.522 2009  to  Thu Feb 19 22:24:14.522 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 128  FAILED    PSF        primaryMirror.command.revert                                  Thu Feb 19 22:32:48.099 2009  to  Thu Feb 19 22:32:52.455 2009   (  4.36) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 129  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 22:32:50.343 2009  to  Thu Feb 19 22:32:52.367 2009   (  2.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 130  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 22:32:50.306 2009  to  Thu Feb 19 22:32:52.400 2009   (  2.09) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 131  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:40:53.204 2009  to  Thu Feb 19 22:40:53.204 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 132  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:40:53.180 2009  to  Thu Feb 19 22:40:53.180 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 133  FAILED    PMC        VxInterface.close                                             Thu Feb 19 22:56:23.782 2009  to  Thu Feb 19 22:56:23.782 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 134  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 22:56:23.762 2009  to  Thu Feb 19 22:56:23.762 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 135  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 23:06:33.898 2009  to  Thu Feb 19 23:11:35.859 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 136  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 23:06:34.165 2009  to  Thu Feb 19 23:06:34.165 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 137  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:12:01.006 2009  to  Thu Feb 19 23:12:01.006 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 138  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:12:00.988 2009  to  Thu Feb 19 23:12:00.988 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 139  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:16:25.000 2009  to  Thu Feb 19 23:16:25.000 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 140  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:16:24.981 2009  to  Thu Feb 19 23:16:24.981 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 141  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:16:34.214 2009  to  Thu Feb 19 23:16:34.214 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 142  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:16:34.180 2009  to  Thu Feb 19 23:16:34.180 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 143  FAILED    PMC        VxInterface.connect.failed                                    Thu Feb 19 23:21:13.083 2009  to  Thu Feb 19 23:21:13.083 2009   (  0.00) secs
                    right PMC Thermal failed to connect to IP 10.144.0.205 port 50009

 144  FAILED    PMC        thermal.badSend                                               Thu Feb 19 23:21:14.107 2009  to  Thu Feb 19 23:21:14.107 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad send to thermal computer, error is pmc.vxWorks.connection.failed

 145  FAILED    PMC        VxInterface.close                                             Thu Feb 19 23:28:51.756 2009  to  Thu Feb 19 23:28:51.756 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 23:28:51.735 2009  to  Thu Feb 19 23:28:51.735 2009   (  0.00) secs
                    right PMC ServoLoop length error: expected 544, got 96

 147  FAILED    IIF        command.sendWavefront                                         Thu Feb 19 23:40:11.974 2009  to  Thu Feb 19 23:40:20.935 2009   (  8.96) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for right LBC for M1

 148  FAILED    PSF        command.applyZernikes                                         Thu Feb 19 23:40:12.041 2009  to  Thu Feb 19 23:40:20.851 2009   (  8.81) secs
                    right PSF ApplyZernikes failed

 149  FAILED    PSF        command.setZernikes                                           Thu Feb 19 23:40:12.009 2009  to  Thu Feb 19 23:40:20.877 2009   (  8.87) secs
                    right PSF SetZernikes failed for 28 coefficients to ope M1

 150  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Feb 19 23:40:12.126 2009  to  Thu Feb 19 23:40:20.814 2009   (  8.69) secs
                    right PSF primary mirror force adjustments failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 151  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 23:40:14.718 2009  to  Thu Feb 19 23:40:20.749 2009   (  6.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 152  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 23:40:14.682 2009  to  Thu Feb 19 23:40:20.785 2009   (  6.10) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 153  FAILED    PMC        VxInterface.close                                             Fri Feb 20 00:13:43.245 2009  to  Fri Feb 20 00:13:43.245 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 00:13:43.226 2009  to  Fri Feb 20 00:13:43.226 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 155  FAILED    PMC        VxInterface.close                                             Fri Feb 20 00:15:33.530 2009  to  Fri Feb 20 00:15:33.530 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 156  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 00:15:33.509 2009  to  Fri Feb 20 00:15:33.509 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 157  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:04:54.278 2009  to  Fri Feb 20 01:04:54.278 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 158  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:04:54.258 2009  to  Fri Feb 20 01:04:54.258 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 159  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:50:22.410 2009  to  Fri Feb 20 01:50:22.410 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 160  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:50:22.388 2009  to  Fri Feb 20 01:50:22.388 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 161  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 01:51:19.461 2009  to  Fri Feb 20 02:06:00.577 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 162  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 01:51:19.728 2009  to  Fri Feb 20 01:51:19.728 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 163  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 01:51:21.799 2009  to  Fri Feb 20 01:51:26.122 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 164  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 01:51:21.837 2009  to  Fri Feb 20 01:51:26.183 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 165  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:51:22.199 2009  to  Fri Feb 20 01:51:22.199 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 166  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:51:22.179 2009  to  Fri Feb 20 01:51:22.179 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 167  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:51:22.556 2009  to  Fri Feb 20 01:51:22.556 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 168  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:51:22.534 2009  to  Fri Feb 20 01:51:22.534 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 169  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 01:51:35.909 2009  to  Fri Feb 20 01:51:35.909 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 170  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 01:51:35.952 2009  to  Fri Feb 20 01:51:35.952 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 171  FAILED    PMC        VxInterface.close                                             Fri Feb 20 01:52:45.787 2009  to  Fri Feb 20 01:52:45.787 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 172  FAILED    PMC        VxInterface.lengthError                                       Fri Feb 20 01:52:45.767 2009  to  Fri Feb 20 01:52:45.767 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 173  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:03:13.188 2009  to  Fri Feb 20 03:27:43.238 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 174  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:03:13.458 2009  to  Fri Feb 20 03:03:13.458 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 175  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:27:43.238 2009  to  Fri Feb 20 03:35:05.671 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 176  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 03:27:43.519 2009  to  Fri Feb 20 03:27:43.519 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 177  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:10:11.807 2009  to  Fri Feb 20 04:30:19.167 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 178  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:10:12.127 2009  to  Fri Feb 20 04:10:12.127 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 179  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:56:05.215 2009  to  Fri Feb 20 05:36:34.599 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 180  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 04:56:05.485 2009  to  Fri Feb 20 04:56:05.485 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 181  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 05:36:34.599 2009  to  Fri Feb 20 06:10:40.970 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 182  SEQERROR  PCS        telescope.command.startTracking                               Fri Feb 20 05:36:34.866 2009  to  Fri Feb 20 05:36:34.866 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 183  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 06:50:28.315 2009  to  Fri Feb 20 06:50:35.786 2009   (  7.47) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 184  FAILED    PSF        primaryMirror.command.revert                                  Fri Feb 20 06:50:29.335 2009  to  Fri Feb 20 06:50:33.692 2009   (  4.36) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 185  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 06:50:31.497 2009  to  Fri Feb 20 06:50:33.636 2009   (  2.14) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 186  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 06:50:31.540 2009  to  Fri Feb 20 06:50:33.571 2009   (  2.03) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 187  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Feb 20 06:50:33.600 2009  to  Fri Feb 20 06:50:35.756 2009   (  2.16) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 188  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Feb 20 06:50:33.664 2009  to  Fri Feb 20 06:50:35.719 2009   (  2.05) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

**********************************************************
    Reporting period ending:   Fri Feb 20 07:27:59.460 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing