You are here: Foswiki>Software Web>TCSSWReportFile_090218 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Feb 18 2009 to Feb 19 2009
 
    Reporting period beginning:   Wed Feb 18 17:37:01.554 2009
    Reporting period ending:      Thu Feb 19 07:28:53.418 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = ecs.lights.command.disable.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.07   100.0 %        107        107                      
                                                                       0.01    0.02    0.01    0.07
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.19    0.27    0.12    0.95   100.0 %        956        956                      
                                                                       0.19    0.27    0.12    0.95
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.06    0.05    0.23   100.0 %        126        126                      
                                                                       0.03    0.06    0.05    0.23
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    6.03    6.38    2.19  122.51    99.1 %        949        940          9           
                                                                       4.70    6.23    2.19   67.49
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.51    5.92    2.93    8.82   100.0 %        138        138                      
                                                                       1.51    5.92    2.93    8.82
     command.offset.telescopeWait . . . . . . . . . . . . . . . . .    1.52    5.37    2.62    8.44   100.0 %        138        138                      
                                                                       1.52    5.37    2.62    8.44
     command.preset.elevationWait . . . . . . . . . . . . . . . . .   16.70   14.31    1.01   49.11   100.0 %         35         35                      
                                                                      16.70   14.31    1.01   49.11
     command.preset.telescopeWait . . . . . . . . . . . . . . . . .   26.11   15.28    2.03   95.20   100.0 %         35         35                      
                                                                      26.11   15.28    2.03   95.20
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   45.62   43.38    7.16  153.17    97.1 %         35         34                     1
                                                                      45.62   43.38    7.16  153.17
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    6.15    5.93    0.32   55.44   100.0 %        373        373                      
                                                                       6.15    5.93    0.32   55.44
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.49    4.52    2.19    6.29   100.0 %         60         60                      
                                                                       1.49    4.52    2.19    6.29

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Wed Feb 18 19:29:30.596 2009  to  Wed Feb 18 19:29:45.866 2009   ( 15.27) secs
                    IIF MoveFocus command started for left LBC for 8.300000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.900000000000000e-02

   2  FAILED    IIF        command.moveFocus                                             Wed Feb 18 20:15:31.921 2009  to  Wed Feb 18 20:15:39.165 2009   (  7.24) secs
                    IIF MoveFocus command started for right LBC for 7.000000000000001e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.000000000000001e-02

   3  FAILED    IIF        command.moveFocus                                             Wed Feb 18 20:24:07.253 2009  to  Wed Feb 18 20:24:13.536 2009   (  6.28) secs
                    IIF MoveFocus command started for right LBC for 8.900000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.900000000000000e-02

   4  FAILED    IIF        command.moveFocus                                             Wed Feb 18 21:09:09.593 2009  to  Wed Feb 18 21:11:12.101 2009   (122.51) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488117303240741e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   5  FAILED    IIF        command.moveFocus                                             Wed Feb 18 21:42:04.284 2009  to  Wed Feb 18 21:42:22.710 2009   ( 18.43) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488119589120370e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Thu Feb 19 00:22:27.266 2009  to  Thu Feb 19 00:22:35.571 2009   (  8.31) secs
                    IIF MoveFocus command started for right LBC for 7.000000000000001e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.000000000000001e-02

   7  FAILED    IIF        command.moveFocus                                             Thu Feb 19 02:48:47.107 2009  to  Thu Feb 19 02:48:50.369 2009   (  3.26) secs
                    IIF MoveFocus command started for right LBC for 8.100000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

   8  FAILED    IIF        command.moveFocus                                             Thu Feb 19 03:19:26.348 2009  to  Thu Feb 19 03:19:32.724 2009   (  6.38) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

   9  FAILED    IIF        command.moveFocus                                             Thu Feb 19 06:35:03.627 2009  to  Thu Feb 19 06:35:11.977 2009   (  8.35) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488156601851852e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4312                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8624                      
                                                                                                   
     lights.command.disable . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      84                      

ECS Events of Interest

   1  SXDXBOTH  ECS        lights.command.disable                                        Thu Feb 19 07:18:04.088 2009  to  Thu Feb 19 07:18:04.088 2009   (  0.00) secs
                    
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         36                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       4                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       3                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             7
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       9                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            46
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      36                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      74                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     830                      
     MCSPU.onSourceChange . . . . . . . . . . . . . . . . . . . . .    1056                      
     MCSPU.MCSPU.AzElOnSourceChange . . . . . . . . . . . . . . . .     352                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed Feb 18 17:42:57.254 2009  to  Wed Feb 18 17:42:57.254 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.01    0.01    0.06   100.0 %        126        126                      
                                                                       0.01    0.01    0.01    0.06
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.09    0.06    0.19   100.0 %        956        956                      
                                                                       0.02    0.09    0.06    0.19
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.14    0.14    0.01    0.63   100.0 %        138        138                      
                                                                       0.14    0.14    0.01    0.63
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.10    0.28    0.02    0.50   100.0 %         37         37                      
                                                                       0.10    0.28    0.02    0.50
 *** telescope.command.startTracking. . . . . . . . . . . . . . . .    0.34    0.36    0.00    0.79     0.0 %         37                    37           
                                                                       0.13    0.64    0.52    0.79

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryError . . . . . . . . . . . . . . . . . . .                  1           
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           

PCS Events of Interest

   1  FAILED    PCS        telescope.telemetryError                                      Wed Feb 18 18:21:03.159 2009  to  Wed Feb 18 18:21:03.159 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   2  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 18:21:03.195 2009  to  Wed Feb 18 18:58:59.854 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   3  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 18:21:03.463 2009  to  Wed Feb 18 18:21:03.463 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   4  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 19:20:27.954 2009  to  Wed Feb 18 19:49:49.953 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   5  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 19:20:28.222 2009  to  Wed Feb 18 19:20:28.222 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   6  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:00:42.002 2009  to  Wed Feb 18 20:08:51.925 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   7  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:00:42.271 2009  to  Wed Feb 18 20:00:42.271 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   8  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:22:50.492 2009  to  Wed Feb 18 20:37:25.254 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   9  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:22:50.760 2009  to  Wed Feb 18 20:22:50.760 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  10  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:37:25.254 2009  to  Wed Feb 18 20:54:48.981 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  11  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:37:25.524 2009  to  Wed Feb 18 20:37:25.524 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  12  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:15:31.405 2009  to  Wed Feb 18 21:26:26.170 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  13  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:15:31.676 2009  to  Wed Feb 18 21:15:31.676 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  14  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:38:43.511 2009  to  Wed Feb 18 22:09:10.424 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  15  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:38:43.779 2009  to  Wed Feb 18 21:38:43.779 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  16  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 23:48:32.263 2009  to  Thu Feb 19 00:00:09.816 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  17  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 23:48:32.531 2009  to  Wed Feb 18 23:48:32.531 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  18  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 00:00:09.816 2009  to  Thu Feb 19 00:12:03.263 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  19  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 00:00:10.081 2009  to  Thu Feb 19 00:00:10.081 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  20  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 00:59:26.544 2009  to  Thu Feb 19 00:59:26.544 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

  21  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 01:34:51.651 2009  to  Thu Feb 19 02:33:08.635 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  22  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 01:34:51.919 2009  to  Thu Feb 19 01:34:51.919 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  23  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 03:53:07.680 2009  to  Thu Feb 19 04:04:30.545 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  24  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 03:53:07.949 2009  to  Thu Feb 19 03:53:07.949 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  25  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 04:15:11.104 2009  to  Thu Feb 19 05:21:12.082 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  26  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 04:15:11.372 2009  to  Thu Feb 19 04:15:11.372 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  27  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 05:21:12.350 2009  to  Thu Feb 19 05:21:12.350 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.07    2.56    2.02    6.03   100.0 %        101        101                      
                                                                       1.07    2.56    2.02    6.03
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    8.03    8.03    8.03   100.0 %          1          1                      
                                                                       0.00    8.03    8.03    8.03
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.98    1.16    0.00    2.02     0.0 %          6                     6           
                                                                       0.90    1.39    0.12    2.02
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    6.92    6.22    2.02  122.26    98.9 %       1420       1405         15           
                                                                       5.57    6.03    2.02   67.15

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            55
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 50           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 50           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      50                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     101                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                           649
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           164
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           163
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 18:45:44.478 2009  to  Wed Feb 18 18:45:44.478 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Wed Feb 18 18:45:44.493 2009  to  Wed Feb 18 18:45:44.493 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.close                                             Wed Feb 18 18:45:45.464 2009  to  Wed Feb 18 18:45:45.464 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 18:45:45.441 2009  to  Wed Feb 18 18:45:45.441 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:17:56.104 2009  to  Wed Feb 18 19:17:56.104 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   6  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:17:56.085 2009  to  Wed Feb 18 19:17:56.085 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   7  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:18:14.564 2009  to  Wed Feb 18 19:18:14.564 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:18:14.550 2009  to  Wed Feb 18 19:18:14.550 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 19:29:30.684 2009  to  Wed Feb 18 19:29:45.729 2009   ( 15.04) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:29:35.394 2009  to  Wed Feb 18 19:29:35.394 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  11  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:29:35.379 2009  to  Wed Feb 18 19:29:35.379 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  12  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:38:59.464 2009  to  Wed Feb 18 19:38:59.464 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  13  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:38:59.479 2009  to  Wed Feb 18 19:38:59.479 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 20:15:32.014 2009  to  Wed Feb 18 20:15:39.043 2009   (  7.03) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:15:36.861 2009  to  Wed Feb 18 20:15:36.861 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  16  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:15:36.883 2009  to  Wed Feb 18 20:15:36.883 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  17  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:22:58.070 2009  to  Wed Feb 18 20:22:58.070 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:22:58.137 2009  to  Wed Feb 18 20:22:58.137 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 20:24:07.345 2009  to  Wed Feb 18 20:24:13.376 2009   (  6.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:29:33.628 2009  to  Wed Feb 18 20:29:33.628 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:29:33.612 2009  to  Wed Feb 18 20:29:33.612 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:32:30.508 2009  to  Wed Feb 18 20:32:30.508 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:32:30.533 2009  to  Wed Feb 18 20:32:30.533 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  24  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:38:50.065 2009  to  Wed Feb 18 20:38:50.065 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  25  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:38:50.050 2009  to  Wed Feb 18 20:38:50.050 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  26  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:41:02.147 2009  to  Wed Feb 18 20:41:02.147 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  27  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:41:02.130 2009  to  Wed Feb 18 20:41:02.130 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  28  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:09:09.710 2009  to  Wed Feb 18 21:11:11.967 2009   (122.26) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  29  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:18:13.593 2009  to  Wed Feb 18 21:18:13.593 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:18:13.576 2009  to  Wed Feb 18 21:18:13.576 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  31  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:32:05.970 2009  to  Wed Feb 18 21:32:05.970 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  32  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:32:05.952 2009  to  Wed Feb 18 21:32:05.952 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  33  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:33:24.159 2009  to  Wed Feb 18 21:33:24.159 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:33:24.141 2009  to  Wed Feb 18 21:33:24.141 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  35  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:33:56.249 2009  to  Wed Feb 18 21:33:56.249 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  36  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:33:56.275 2009  to  Wed Feb 18 21:33:56.275 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  37  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:34:49.256 2009  to  Wed Feb 18 21:34:49.256 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:34:49.229 2009  to  Wed Feb 18 21:34:49.229 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  39  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:42:04.474 2009  to  Wed Feb 18 21:42:22.553 2009   ( 18.08) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  40  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:50:08.925 2009  to  Wed Feb 18 21:50:12.947 2009   (  4.02) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  41  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:50:14.451 2009  to  Wed Feb 18 21:52:01.677 2009   (107.23) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:03.347 2009  to  Wed Feb 18 21:52:23.401 2009   ( 20.05) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:25.187 2009  to  Wed Feb 18 21:52:47.245 2009   ( 22.06) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  SEQERROR  PMC        mirror.command.chase.stop                                     Wed Feb 18 21:52:46.633 2009  to  Wed Feb 18 21:52:52.537 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  45  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:48.499 2009  to  Wed Feb 18 21:52:53.524 2009   (  5.02) secs
                    Started event but no Complete event
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  46  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:54.085 2009  to  Wed Feb 18 21:53:02.118 2009   (  8.03) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  47  SEQERROR  PMC        mirror.command.chase.stop                                     Wed Feb 18 21:53:03.841 2009  to  Wed Feb 18 21:53:03.841 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror ChaseStop Command Complete

  48  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:33:01.129 2009  to  Wed Feb 18 22:33:01.129 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:33:01.113 2009  to  Wed Feb 18 22:33:01.113 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:35:12.309 2009  to  Wed Feb 18 22:35:12.309 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:35:12.293 2009  to  Wed Feb 18 22:35:12.293 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:48:51.083 2009  to  Wed Feb 18 22:48:51.083 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:48:51.066 2009  to  Wed Feb 18 22:48:51.066 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:12:28.954 2009  to  Wed Feb 18 23:12:28.954 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  55  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:12:28.972 2009  to  Wed Feb 18 23:12:28.972 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  56  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:25:59.549 2009  to  Wed Feb 18 23:25:59.549 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:25:59.533 2009  to  Wed Feb 18 23:25:59.533 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:53:46.820 2009  to  Wed Feb 18 23:53:46.820 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:53:46.784 2009  to  Wed Feb 18 23:53:46.784 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:57:04.067 2009  to  Wed Feb 18 23:57:04.067 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:57:04.049 2009  to  Wed Feb 18 23:57:04.049 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  62  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 00:07:38.152 2009  to  Thu Feb 19 00:07:38.152 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Thu Feb 19 00:07:38.167 2009  to  Thu Feb 19 00:07:38.167 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  64  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 00:22:27.398 2009  to  Thu Feb 19 00:22:35.435 2009   (  8.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 02:48:47.198 2009  to  Thu Feb 19 02:48:50.225 2009   (  3.03) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 03:19:26.532 2009  to  Thu Feb 19 03:19:32.557 2009   (  6.02) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  67  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 06:35:03.769 2009  to  Thu Feb 19 06:35:11.810 2009   (  8.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    6.15    5.83    0.22   55.33   100.0 %        373        373                      
                                                                       6.15    5.83    0.22   55.33
     command.secondaryOffload . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.06   100.0 %         70         70                      
                                                                       0.01    0.02    0.01    0.06
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    5.87    6.20    2.14  122.42    99.1 %       1009       1000          9           
                                                                       4.59    6.06    2.14   67.31
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    6.15    5.87    0.25   55.37   100.0 %        373        373                      
                                                                       6.15    5.87    0.25   55.37
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.22    5.81    0.15   55.26   100.0 %        375        375                      
                                                                       6.22    5.81    0.15   55.26
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    6.92    6.29    2.07  122.32    98.9 %       1420       1405         15           
                                                                       5.57    6.10    2.07   67.21
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.99    1.20    0.00    2.08     0.0 %          6                     6           
                                                                       0.89    1.44    0.18    2.08
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    8.13    8.13    8.13   100.0 %          1          1                      
                                                                       0.00    8.13    8.13    8.13
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.06    0.03    0.37   100.0 %        226        226                      
                                                                       0.04    0.06    0.03    0.37
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   12.27   12.27   12.27     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    5.87    6.15    2.10  122.37    99.1 %       1009       1000          9           
                                                                       4.59    6.01    2.10   67.26
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.03    0.04    0.02    0.06   100.0 %          2          2                      
                                                                       0.03    0.04    0.02    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.02    0.02    0.01    0.48   100.0 %        375        375                      
                                                                       0.02    0.02    0.01    0.48

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .                 95           

PSF Events of Interest

   1  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 19:29:30.627 2009  to  Wed Feb 18 19:29:45.803 2009   ( 15.18) secs
                    right PSF SetInstrumentOffsets failed

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 19:29:30.659 2009  to  Wed Feb 18 19:29:45.758 2009   ( 15.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 19:29:30.641 2009  to  Wed Feb 18 19:29:45.779 2009   ( 15.14) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   4  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 20:15:31.945 2009  to  Wed Feb 18 20:15:39.112 2009   (  7.17) secs
                    right PSF SetInstrumentOffsets failed

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 20:15:31.981 2009  to  Wed Feb 18 20:15:39.071 2009   (  7.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 20:15:31.963 2009  to  Wed Feb 18 20:15:39.090 2009   (  7.13) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   7  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 20:24:07.280 2009  to  Wed Feb 18 20:24:13.459 2009   (  6.18) secs
                    right PSF SetInstrumentOffsets failed

   8  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 20:24:07.313 2009  to  Wed Feb 18 20:24:13.405 2009   (  6.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 20:24:07.297 2009  to  Wed Feb 18 20:24:13.437 2009   (  6.14) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  10  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 20:57:15.171 2009  to  Wed Feb 18 20:57:15.171 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.1143427e-04 -2.7740002e-04 -7.1072578e-04 1.5201473e-01 -4.8551559e-02 -3.4919739e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 20:57:15.398 2009  to  Wed Feb 18 20:57:15.398 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.1143427e-04 -2.7740002e-04 -7.1072578e-04 1.5201473e-01 -4.8551559e-02 -3.4919739e-02

  12  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 21:09:09.629 2009  to  Wed Feb 18 21:11:12.046 2009   (122.42) secs
                    right PSF SetInstrumentOffsets failed

  13  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 21:09:09.648 2009  to  Wed Feb 18 21:11:12.018 2009   (122.37) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  14  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:09:09.678 2009  to  Wed Feb 18 21:11:11.996 2009   (122.32) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 21:42:04.333 2009  to  Wed Feb 18 21:42:22.651 2009   ( 18.32) secs
                    right PSF SetInstrumentOffsets failed

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:42:04.411 2009  to  Wed Feb 18 21:42:22.585 2009   ( 18.17) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 21:42:04.365 2009  to  Wed Feb 18 21:42:22.613 2009   ( 18.25) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  18  FAILED    PSF        primaryMirror.command.revert                                  Wed Feb 18 21:50:00.726 2009  to  Wed Feb 18 21:50:12.994 2009   ( 12.27) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:50:08.897 2009  to  Wed Feb 18 21:50:12.975 2009   (  4.08) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  20  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:50:14.417 2009  to  Wed Feb 18 21:52:01.762 2009   (107.35) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:03.321 2009  to  Wed Feb 18 21:52:23.430 2009   ( 20.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:25.155 2009  to  Wed Feb 18 21:52:47.276 2009   ( 22.12) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  SEQERROR  PSF        primaryMirror.command.chaseStop                               Wed Feb 18 21:52:46.611 2009  to  Wed Feb 18 21:52:52.506 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:48.469 2009  to  Wed Feb 18 21:52:53.553 2009   (  5.08) secs
                    Started event but no Complete event
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:54.061 2009  to  Wed Feb 18 21:53:02.148 2009   (  8.09) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  26  SEQERROR  PSF        primaryMirror.command.chaseStop                               Wed Feb 18 21:53:03.870 2009  to  Wed Feb 18 21:53:03.870 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror chaseStop complete

  27  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.144 2009  to  Wed Feb 18 22:06:48.144 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  28  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.365 2009  to  Wed Feb 18 22:06:48.365 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.585 2009  to  Wed Feb 18 22:06:48.585 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  30  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:51.648 2009  to  Wed Feb 18 22:06:51.648 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7857552e-03 7.4672699e-04 7.6621771e-04 -1.6786957e-01 -7.5378418e-03 4.6619415e-02

  31  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:51.868 2009  to  Wed Feb 18 22:06:51.868 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7857552e-03 7.4672699e-04 7.6621771e-04 -1.6786957e-01 -7.5378418e-03 4.6619415e-02

  32  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.511 2009  to  Wed Feb 18 22:06:54.511 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.735 2009  to  Wed Feb 18 22:06:54.735 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.954 2009  to  Wed Feb 18 22:06:54.954 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  35  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:55.982 2009  to  Wed Feb 18 22:06:55.982 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:56.201 2009  to  Wed Feb 18 22:06:56.201 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

  37  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:56.418 2009  to  Wed Feb 18 22:06:56.418 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

  38  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:00.877 2009  to  Wed Feb 18 22:07:00.877 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  39  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.100 2009  to  Wed Feb 18 22:07:01.100 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.322 2009  to  Wed Feb 18 22:07:01.322 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.540 2009  to  Wed Feb 18 22:07:01.540 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.754 2009  to  Wed Feb 18 22:07:01.754 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.977 2009  to  Wed Feb 18 22:07:01.977 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  44  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:02.197 2009  to  Wed Feb 18 22:07:02.197 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:06.268 2009  to  Wed Feb 18 22:07:06.268 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  46  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:06.490 2009  to  Wed Feb 18 22:07:06.490 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  47  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:07.724 2009  to  Wed Feb 18 22:07:07.724 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  48  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:07.987 2009  to  Wed Feb 18 22:07:07.987 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

  49  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:15.078 2009  to  Wed Feb 18 22:07:15.078 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.4738312e-03 1.4108419e-04 1.1520088e-03 -1.8172646e-01 2.0294189e-03 2.5703907e-02

  50  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 00:22:27.293 2009  to  Thu Feb 19 00:22:35.510 2009   (  8.22) secs
                    right PSF SetInstrumentOffsets failed

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 00:22:27.353 2009  to  Thu Feb 19 00:22:35.468 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 00:22:27.322 2009  to  Thu Feb 19 00:22:35.487 2009   (  8.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  53  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 02:48:47.136 2009  to  Thu Feb 19 02:48:50.307 2009   (  3.17) secs
                    right PSF SetInstrumentOffsets failed

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 02:48:47.168 2009  to  Thu Feb 19 02:48:50.259 2009   (  3.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  55  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 02:48:47.152 2009  to  Thu Feb 19 02:48:50.280 2009   (  3.13) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  56  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 03:19:26.476 2009  to  Thu Feb 19 03:19:32.663 2009   (  6.19) secs
                    right PSF SetInstrumentOffsets failed

  57  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 03:19:26.508 2009  to  Thu Feb 19 03:19:32.589 2009   (  6.08) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 03:19:26.493 2009  to  Thu Feb 19 03:19:32.643 2009   (  6.15) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  59  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 06:35:03.668 2009  to  Thu Feb 19 06:35:11.886 2009   (  8.22) secs
                    right PSF SetInstrumentOffsets failed

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 06:35:03.736 2009  to  Thu Feb 19 06:35:11.845 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 06:35:03.703 2009  to  Thu Feb 19 06:35:11.866 2009   (  8.16) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Wed Feb 18 17:42:57.254 2009  to  Wed Feb 18 17:42:57.254 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

   2  FAILED    PCS        telescope.telemetryError                                      Wed Feb 18 18:21:03.159 2009  to  Wed Feb 18 18:21:03.159 2009   (  0.00) secs
                    PCS Telescope telemetry error: No telemetry since telemeter registration failed.

   3  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 18:21:03.195 2009  to  Wed Feb 18 18:58:59.854 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 18:21:03.463 2009  to  Wed Feb 18 18:21:03.463 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 18:45:44.478 2009  to  Wed Feb 18 18:45:44.478 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   6  FAILED    PMC        VxInterface.close                                             Wed Feb 18 18:45:44.493 2009  to  Wed Feb 18 18:45:44.493 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   7  FAILED    PMC        VxInterface.close                                             Wed Feb 18 18:45:45.464 2009  to  Wed Feb 18 18:45:45.464 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   8  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 18:45:45.441 2009  to  Wed Feb 18 18:45:45.441 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   9  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:17:56.104 2009  to  Wed Feb 18 19:17:56.104 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  10  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:17:56.085 2009  to  Wed Feb 18 19:17:56.085 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  11  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:18:14.564 2009  to  Wed Feb 18 19:18:14.564 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  12  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:18:14.550 2009  to  Wed Feb 18 19:18:14.550 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  13  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 19:20:27.954 2009  to  Wed Feb 18 19:49:49.953 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 19:20:28.222 2009  to  Wed Feb 18 19:20:28.222 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  FAILED    IIF        command.moveFocus                                             Wed Feb 18 19:29:30.596 2009  to  Wed Feb 18 19:29:45.866 2009   ( 15.27) secs
                    IIF MoveFocus command started for left LBC for 8.300000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.900000000000000e-02

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 19:29:30.684 2009  to  Wed Feb 18 19:29:45.729 2009   ( 15.04) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 19:29:30.627 2009  to  Wed Feb 18 19:29:45.803 2009   ( 15.18) secs
                    right PSF SetInstrumentOffsets failed

  18  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 19:29:30.659 2009  to  Wed Feb 18 19:29:45.758 2009   ( 15.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 19:29:30.641 2009  to  Wed Feb 18 19:29:45.779 2009   ( 15.14) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  20  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:29:35.394 2009  to  Wed Feb 18 19:29:35.394 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:29:35.379 2009  to  Wed Feb 18 19:29:35.379 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 19:38:59.464 2009  to  Wed Feb 18 19:38:59.464 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        VxInterface.close                                             Wed Feb 18 19:38:59.479 2009  to  Wed Feb 18 19:38:59.479 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  24  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:00:42.002 2009  to  Wed Feb 18 20:08:51.925 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  25  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:00:42.271 2009  to  Wed Feb 18 20:00:42.271 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  26  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 20:15:31.945 2009  to  Wed Feb 18 20:15:39.112 2009   (  7.17) secs
                    right PSF SetInstrumentOffsets failed

  27  FAILED    IIF        command.moveFocus                                             Wed Feb 18 20:15:31.921 2009  to  Wed Feb 18 20:15:39.165 2009   (  7.24) secs
                    IIF MoveFocus command started for right LBC for 7.000000000000001e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.000000000000001e-02

  28  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 20:15:32.014 2009  to  Wed Feb 18 20:15:39.043 2009   (  7.03) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 20:15:31.981 2009  to  Wed Feb 18 20:15:39.071 2009   (  7.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  30  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 20:15:31.963 2009  to  Wed Feb 18 20:15:39.090 2009   (  7.13) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  31  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:15:36.861 2009  to  Wed Feb 18 20:15:36.861 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:15:36.883 2009  to  Wed Feb 18 20:15:36.883 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  33  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:22:50.492 2009  to  Wed Feb 18 20:37:25.254 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  34  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:22:50.760 2009  to  Wed Feb 18 20:22:50.760 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  35  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:22:58.070 2009  to  Wed Feb 18 20:22:58.070 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  36  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:22:58.137 2009  to  Wed Feb 18 20:22:58.137 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  37  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 20:24:07.280 2009  to  Wed Feb 18 20:24:13.459 2009   (  6.18) secs
                    right PSF SetInstrumentOffsets failed

  38  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 20:24:07.313 2009  to  Wed Feb 18 20:24:13.405 2009   (  6.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 20:24:07.297 2009  to  Wed Feb 18 20:24:13.437 2009   (  6.14) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  40  FAILED    IIF        command.moveFocus                                             Wed Feb 18 20:24:07.253 2009  to  Wed Feb 18 20:24:13.536 2009   (  6.28) secs
                    IIF MoveFocus command started for right LBC for 8.900000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.900000000000000e-02

  41  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 20:24:07.345 2009  to  Wed Feb 18 20:24:13.376 2009   (  6.03) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  42  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:29:33.628 2009  to  Wed Feb 18 20:29:33.628 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:29:33.612 2009  to  Wed Feb 18 20:29:33.612 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:32:30.508 2009  to  Wed Feb 18 20:32:30.508 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  45  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:32:30.533 2009  to  Wed Feb 18 20:32:30.533 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  46  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:37:25.254 2009  to  Wed Feb 18 20:54:48.981 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  47  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 20:37:25.524 2009  to  Wed Feb 18 20:37:25.524 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  48  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:38:50.065 2009  to  Wed Feb 18 20:38:50.065 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:38:50.050 2009  to  Wed Feb 18 20:38:50.050 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.close                                             Wed Feb 18 20:41:02.147 2009  to  Wed Feb 18 20:41:02.147 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 20:41:02.130 2009  to  Wed Feb 18 20:41:02.130 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  52  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 20:57:15.171 2009  to  Wed Feb 18 20:57:15.171 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.1143427e-04 -2.7740002e-04 -7.1072578e-04 1.5201473e-01 -4.8551559e-02 -3.4919739e-02

  53  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 20:57:15.398 2009  to  Wed Feb 18 20:57:15.398 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -3.1143427e-04 -2.7740002e-04 -7.1072578e-04 1.5201473e-01 -4.8551559e-02 -3.4919739e-02

  54  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 21:09:09.629 2009  to  Wed Feb 18 21:11:12.046 2009   (122.42) secs
                    right PSF SetInstrumentOffsets failed

  55  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 21:09:09.648 2009  to  Wed Feb 18 21:11:12.018 2009   (122.37) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  56  FAILED    IIF        command.moveFocus                                             Wed Feb 18 21:09:09.593 2009  to  Wed Feb 18 21:11:12.101 2009   (122.51) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488117303240741e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  57  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:09:09.710 2009  to  Wed Feb 18 21:11:11.967 2009   (122.26) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:09:09.678 2009  to  Wed Feb 18 21:11:11.996 2009   (122.32) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:15:31.405 2009  to  Wed Feb 18 21:26:26.170 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  60  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:15:31.676 2009  to  Wed Feb 18 21:15:31.676 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  61  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:18:13.593 2009  to  Wed Feb 18 21:18:13.593 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:18:13.576 2009  to  Wed Feb 18 21:18:13.576 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  63  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:32:05.970 2009  to  Wed Feb 18 21:32:05.970 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:32:05.952 2009  to  Wed Feb 18 21:32:05.952 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  65  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:33:24.159 2009  to  Wed Feb 18 21:33:24.159 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:33:24.141 2009  to  Wed Feb 18 21:33:24.141 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:33:56.249 2009  to  Wed Feb 18 21:33:56.249 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  68  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:33:56.275 2009  to  Wed Feb 18 21:33:56.275 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  69  FAILED    PMC        VxInterface.close                                             Wed Feb 18 21:34:49.256 2009  to  Wed Feb 18 21:34:49.256 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 21:34:49.229 2009  to  Wed Feb 18 21:34:49.229 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  71  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:38:43.511 2009  to  Wed Feb 18 22:09:10.424 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  72  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 21:38:43.779 2009  to  Wed Feb 18 21:38:43.779 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  73  FAILED    PSF        command.setInstrumentOffsets                                  Wed Feb 18 21:42:04.333 2009  to  Wed Feb 18 21:42:22.651 2009   ( 18.32) secs
                    right PSF SetInstrumentOffsets failed

  74  FAILED    IIF        command.moveFocus                                             Wed Feb 18 21:42:04.284 2009  to  Wed Feb 18 21:42:22.710 2009   ( 18.43) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488119589120370e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  75  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:42:04.411 2009  to  Wed Feb 18 21:42:22.585 2009   ( 18.17) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  76  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Feb 18 21:42:04.365 2009  to  Wed Feb 18 21:42:22.613 2009   ( 18.25) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  77  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:42:04.474 2009  to  Wed Feb 18 21:42:22.553 2009   ( 18.08) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  78  FAILED    PSF        primaryMirror.command.revert                                  Wed Feb 18 21:50:00.726 2009  to  Wed Feb 18 21:50:12.994 2009   ( 12.27) secs
                    right PSF primary mirror revert to just collimation table failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  79  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:50:08.925 2009  to  Wed Feb 18 21:50:12.947 2009   (  4.02) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  80  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:50:08.897 2009  to  Wed Feb 18 21:50:12.975 2009   (  4.08) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  81  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:50:14.451 2009  to  Wed Feb 18 21:52:01.677 2009   (107.23) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  82  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:50:14.417 2009  to  Wed Feb 18 21:52:01.762 2009   (107.35) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:03.321 2009  to  Wed Feb 18 21:52:23.430 2009   ( 20.11) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:03.347 2009  to  Wed Feb 18 21:52:23.401 2009   ( 20.05) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:25.187 2009  to  Wed Feb 18 21:52:47.245 2009   ( 22.06) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  86  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:25.155 2009  to  Wed Feb 18 21:52:47.276 2009   ( 22.12) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  87  SEQERROR  PSF        primaryMirror.command.chaseStop                               Wed Feb 18 21:52:46.611 2009  to  Wed Feb 18 21:52:52.506 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  88  SEQERROR  PMC        mirror.command.chase.stop                                     Wed Feb 18 21:52:46.633 2009  to  Wed Feb 18 21:52:52.537 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  89  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:48.499 2009  to  Wed Feb 18 21:52:53.524 2009   (  5.02) secs
                    Started event but no Complete event
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  90  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:48.469 2009  to  Wed Feb 18 21:52:53.553 2009   (  5.08) secs
                    Started event but no Complete event
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  91  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Wed Feb 18 21:52:54.061 2009  to  Wed Feb 18 21:53:02.148 2009   (  8.09) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  92  FAILED    PMC        mirror.command.goToPosition.absolute                          Wed Feb 18 21:52:54.085 2009  to  Wed Feb 18 21:53:02.118 2009   (  8.03) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  93  SEQERROR  PMC        mirror.command.chase.stop                                     Wed Feb 18 21:53:03.841 2009  to  Wed Feb 18 21:53:03.841 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror ChaseStop Command Complete

  94  SEQERROR  PSF        primaryMirror.command.chaseStop                               Wed Feb 18 21:53:03.870 2009  to  Wed Feb 18 21:53:03.870 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror chaseStop complete

  95  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.144 2009  to  Wed Feb 18 22:06:48.144 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  96  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.365 2009  to  Wed Feb 18 22:06:48.365 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  97  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:48.585 2009  to  Wed Feb 18 22:06:48.585 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.1324158e-03 1.4728308e-04 3.9243698e-04 -1.5797043e-01 -3.3645630e-03 4.7243118e-02

  98  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:51.648 2009  to  Wed Feb 18 22:06:51.648 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7857552e-03 7.4672699e-04 7.6621771e-04 -1.6786957e-01 -7.5378418e-03 4.6619415e-02

  99  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:51.868 2009  to  Wed Feb 18 22:06:51.868 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7857552e-03 7.4672699e-04 7.6621771e-04 -1.6786957e-01 -7.5378418e-03 4.6619415e-02

 100  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.511 2009  to  Wed Feb 18 22:06:54.511 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 101  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.735 2009  to  Wed Feb 18 22:06:54.735 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 102  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:54.954 2009  to  Wed Feb 18 22:06:54.954 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 103  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:55.982 2009  to  Wed Feb 18 22:06:55.982 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

 104  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:56.201 2009  to  Wed Feb 18 22:06:56.201 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

 105  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:06:56.418 2009  to  Wed Feb 18 22:06:56.418 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

 106  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:00.877 2009  to  Wed Feb 18 22:07:00.877 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 107  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.100 2009  to  Wed Feb 18 22:07:01.100 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 108  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.322 2009  to  Wed Feb 18 22:07:01.322 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 109  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.540 2009  to  Wed Feb 18 22:07:01.540 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

 110  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.754 2009  to  Wed Feb 18 22:07:01.754 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.5987158e-03 -1.5211105e-04 9.6121430e-04 -1.6548347e-01 8.1863403e-03 3.6015034e-02

 111  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:01.977 2009  to  Wed Feb 18 22:07:01.977 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 112  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:02.197 2009  to  Wed Feb 18 22:07:02.197 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 113  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:06.268 2009  to  Wed Feb 18 22:07:06.268 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 114  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:06.490 2009  to  Wed Feb 18 22:07:06.490 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 115  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:07.724 2009  to  Wed Feb 18 22:07:07.724 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 116  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:07.987 2009  to  Wed Feb 18 22:07:07.987 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.7687082e-03 1.5854836e-04 7.7010691e-04 -1.5857887e-01 3.1044006e-02 4.6840668e-02

 117  FAILED    PSF        primaryMirror.positionError                                   Wed Feb 18 22:07:15.078 2009  to  Wed Feb 18 22:07:15.078 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.4738312e-03 1.4108419e-04 1.1520088e-03 -1.8172646e-01 2.0294189e-03 2.5703907e-02

 118  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:33:01.129 2009  to  Wed Feb 18 22:33:01.129 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 119  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:33:01.113 2009  to  Wed Feb 18 22:33:01.113 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 120  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:35:12.309 2009  to  Wed Feb 18 22:35:12.309 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 121  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:35:12.293 2009  to  Wed Feb 18 22:35:12.293 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 122  FAILED    PMC        VxInterface.close                                             Wed Feb 18 22:48:51.083 2009  to  Wed Feb 18 22:48:51.083 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 123  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 22:48:51.066 2009  to  Wed Feb 18 22:48:51.066 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 124  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:12:28.954 2009  to  Wed Feb 18 23:12:28.954 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 125  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:12:28.972 2009  to  Wed Feb 18 23:12:28.972 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 126  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:25:59.549 2009  to  Wed Feb 18 23:25:59.549 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 127  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:25:59.533 2009  to  Wed Feb 18 23:25:59.533 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 128  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 23:48:32.263 2009  to  Thu Feb 19 00:00:09.816 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 129  SEQERROR  PCS        telescope.command.startTracking                               Wed Feb 18 23:48:32.531 2009  to  Wed Feb 18 23:48:32.531 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 130  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:53:46.820 2009  to  Wed Feb 18 23:53:46.820 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 131  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:53:46.784 2009  to  Wed Feb 18 23:53:46.784 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 132  FAILED    PMC        VxInterface.close                                             Wed Feb 18 23:57:04.067 2009  to  Wed Feb 18 23:57:04.067 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

 133  FAILED    PMC        VxInterface.lengthError                                       Wed Feb 18 23:57:04.049 2009  to  Wed Feb 18 23:57:04.049 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

 134  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 00:00:09.816 2009  to  Thu Feb 19 00:12:03.263 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 135  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 00:00:10.081 2009  to  Thu Feb 19 00:00:10.081 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 136  FAILED    PMC        VxInterface.lengthError                                       Thu Feb 19 00:07:38.152 2009  to  Thu Feb 19 00:07:38.152 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 137  FAILED    PMC        VxInterface.close                                             Thu Feb 19 00:07:38.167 2009  to  Thu Feb 19 00:07:38.167 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 138  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 00:22:27.293 2009  to  Thu Feb 19 00:22:35.510 2009   (  8.22) secs
                    right PSF SetInstrumentOffsets failed

 139  FAILED    IIF        command.moveFocus                                             Thu Feb 19 00:22:27.266 2009  to  Thu Feb 19 00:22:35.571 2009   (  8.31) secs
                    IIF MoveFocus command started for right LBC for 7.000000000000001e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.000000000000001e-02

 140  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 00:22:27.353 2009  to  Thu Feb 19 00:22:35.468 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 141  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 00:22:27.322 2009  to  Thu Feb 19 00:22:35.487 2009   (  8.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 142  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 00:22:27.398 2009  to  Thu Feb 19 00:22:35.435 2009   (  8.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 143  FAILED    PCS        guider.telemetryError                                         Thu Feb 19 00:59:26.544 2009  to  Thu Feb 19 00:59:26.544 2009   (  0.00) secs
                    PCS Guider telemetry error: No telemetry since telemeter registration failed.

 144  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 01:34:51.651 2009  to  Thu Feb 19 02:33:08.635 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 145  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 01:34:51.919 2009  to  Thu Feb 19 01:34:51.919 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 146  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 02:48:47.136 2009  to  Thu Feb 19 02:48:50.307 2009   (  3.17) secs
                    right PSF SetInstrumentOffsets failed

 147  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 02:48:47.168 2009  to  Thu Feb 19 02:48:50.259 2009   (  3.09) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 148  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 02:48:47.152 2009  to  Thu Feb 19 02:48:50.280 2009   (  3.13) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 149  FAILED    IIF        command.moveFocus                                             Thu Feb 19 02:48:47.107 2009  to  Thu Feb 19 02:48:50.369 2009   (  3.26) secs
                    IIF MoveFocus command started for right LBC for 8.100000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

 150  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 02:48:47.198 2009  to  Thu Feb 19 02:48:50.225 2009   (  3.03) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 151  FAILED    IIF        command.moveFocus                                             Thu Feb 19 03:19:26.348 2009  to  Thu Feb 19 03:19:32.724 2009   (  6.38) secs
                    IIF MoveFocus command started for right LBC for 7.600000000000000e-02
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 7.600000000000000e-02

 152  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 03:19:26.532 2009  to  Thu Feb 19 03:19:32.557 2009   (  6.02) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 153  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 03:19:26.476 2009  to  Thu Feb 19 03:19:32.663 2009   (  6.19) secs
                    right PSF SetInstrumentOffsets failed

 154  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 03:19:26.508 2009  to  Thu Feb 19 03:19:32.589 2009   (  6.08) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 155  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 03:19:26.493 2009  to  Thu Feb 19 03:19:32.643 2009   (  6.15) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 156  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 03:53:07.680 2009  to  Thu Feb 19 04:04:30.545 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 157  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 03:53:07.949 2009  to  Thu Feb 19 03:53:07.949 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 158  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 04:15:11.104 2009  to  Thu Feb 19 05:21:12.082 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 159  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 04:15:11.372 2009  to  Thu Feb 19 04:15:11.372 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 160  SEQERROR  PCS        telescope.command.startTracking                               Thu Feb 19 05:21:12.350 2009  to  Thu Feb 19 05:21:12.350 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 161  FAILED    IIF        command.moveFocus                                             Thu Feb 19 06:35:03.627 2009  to  Thu Feb 19 06:35:11.977 2009   (  8.35) secs
                    IIF GetTrajectory command started for both LBC, start time 5.488156601851852e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 1.040000000000000e-01

 162  FAILED    PSF        command.setInstrumentOffsets                                  Thu Feb 19 06:35:03.668 2009  to  Thu Feb 19 06:35:11.886 2009   (  8.22) secs
                    right PSF SetInstrumentOffsets failed

 163  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Feb 19 06:35:03.736 2009  to  Thu Feb 19 06:35:11.845 2009   (  8.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 164  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Feb 19 06:35:03.703 2009  to  Thu Feb 19 06:35:11.866 2009   (  8.16) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 165  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Feb 19 06:35:03.769 2009  to  Thu Feb 19 06:35:11.810 2009   (  8.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 166  SXDXBOTH  ECS        lights.command.disable                                        Thu Feb 19 07:18:04.088 2009  to  Thu Feb 19 07:18:04.088 2009   (  0.00) secs
                    

**********************************************************
    Reporting period ending:   Thu Feb 19 07:28:53.418 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.