You are here: Foswiki>Software Web>TCSSWReportFile_090127 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jan 27 2009 to Jan 28 2009
 
    Reporting period beginning:   Tue Jan 27 17:17:01.519 2009
    Reporting period ending:      Wed Jan 28 07:46:59.926 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.08   100.0 %        163        163                      
                                                                       0.01    0.02    0.01    0.08
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.08    0.22    0.12    0.56   100.0 %        385        385                      
                                                                       0.08    0.22    0.12    0.56
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.06    0.09    0.06    0.42   100.0 %        657        657                      
                                                                       0.06    0.09    0.06    0.42
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    9.59    7.82    0.28   91.52    96.1 %        385        370         15           
                                                                       6.93    6.88    2.20   55.43
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    0.57    3.67    2.92    4.94   100.0 %         14         14                      
                                                                       0.57    3.67    2.92    4.94
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   25.10   23.65    6.70  132.41    93.0 %        100         92          7          1
                                                                      21.72   21.01    6.70  108.89
 *** command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    5.61    5.62    0.31   69.33    94.4 %        916        865         51           
                                                                       4.78    5.19    0.31   44.83
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.67    4.80    2.19    7.46   100.0 %         86         86                      
                                                                       1.67    4.80    2.19    7.46

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:17:11.846 2009  to  Tue Jan 27 18:17:38.417 2009   ( 26.57) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485905361111111e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

   2  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:20:22.674 2009  to  Tue Jan 27 18:20:22.956 2009   (  0.28) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

   3  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:22:17.405 2009  to  Tue Jan 27 18:22:23.799 2009   (  6.39) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485905715277778e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

   4  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:23:05.845 2009  to  Tue Jan 27 18:23:06.645 2009   (  0.80) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

   5  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:31:23.932 2009  to  Tue Jan 27 18:32:32.355 2009   ( 68.42) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:03:40.092 2009  to  Tue Jan 27 19:04:49.427 2009   ( 69.33) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

   7  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:10:42.136 2009  to  Tue Jan 27 19:11:09.210 2009   ( 27.07) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

   8  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:15:48.314 2009  to  Tue Jan 27 19:16:00.391 2009   ( 12.08) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

   9  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 20:09:53.170 2009  to  Tue Jan 27 20:10:37.575 2009   ( 44.40) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485913187500000e+04, time 6.450000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  10  FAILED    IIF        command.moveFocus                                             Tue Jan 27 20:10:39.458 2009  to  Tue Jan 27 20:11:19.833 2009   ( 40.38) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  11  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:41:29.780 2009  to  Tue Jan 27 20:41:36.229 2009   (  6.45) secs
                    IIF Guide command started for right LBC, coord1 4.430928058523592e-07, coord2 1.410584253908613e-06, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  12  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:41:50.024 2009  to  Tue Jan 27 20:42:01.600 2009   ( 11.58) secs
                    IIF Guide command started for right LBC, coord1 4.208968291051059e-07, coord2 3.948105233782860e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  13  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:42:58.537 2009  to  Tue Jan 27 20:43:09.022 2009   ( 10.48) secs
                    IIF Guide command started for right LBC, coord1 9.315554847679877e-08, coord2 7.537345700986043e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  14  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:43:23.098 2009  to  Tue Jan 27 20:43:30.582 2009   (  7.48) secs
                    IIF Guide command started for right LBC, coord1 2.159255546483011e-07, coord2 1.630704474280594e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  15  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:44:05.603 2009  to  Tue Jan 27 20:44:13.056 2009   (  7.45) secs
                    IIF Guide command started for right LBC, coord1 4.368154105648823e-07, coord2 6.515685208148007e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  16  FAILED    IIF        command.moveFocus                                             Tue Jan 27 20:47:28.763 2009  to  Tue Jan 27 20:47:46.038 2009   ( 17.28) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  17  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:52:08.697 2009  to  Tue Jan 27 20:52:20.830 2009   ( 12.13) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  18  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 20:55:10.327 2009  to  Tue Jan 27 20:56:15.103 2009   ( 64.78) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485916332175926e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  19  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 21:00:28.047 2009  to  Tue Jan 27 21:01:05.276 2009   ( 37.23) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  20  FAILED    IIF        command.moveFocus                                             Tue Jan 27 21:06:54.430 2009  to  Tue Jan 27 21:07:00.755 2009   (  6.32) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  21  FAILED    IIF        command.moveFocus                                             Tue Jan 27 22:20:45.832 2009  to  Tue Jan 27 22:21:19.194 2009   ( 33.36) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

  22  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:22:39.202 2009  to  Tue Jan 27 22:22:49.778 2009   ( 10.58) secs
                    IIF Guide command started for right LBC, coord1 8.917071665295609e-07, coord2 -1.252423106976413e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  23  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:25:35.541 2009  to  Tue Jan 27 22:25:47.036 2009   ( 11.50) secs
                    IIF Guide command started for right LBC, coord1 3.514235279313115e-07, coord2 8.264102188002629e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  24  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:26:00.771 2009  to  Tue Jan 27 22:26:08.255 2009   (  7.48) secs
                    IIF Guide command started for right LBC, coord1 5.246889411120252e-07, coord2 -3.760543879730371e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  25  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:26:22.436 2009  to  Tue Jan 27 22:26:32.978 2009   ( 10.54) secs
                    IIF Guide command started for right LBC, coord1 -8.208119703094504e-07, coord2 5.657259780562290e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  26  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 22:27:51.063 2009  to  Tue Jan 27 22:28:14.057 2009   ( 22.99) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485922768518519e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  27  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:30:39.404 2009  to  Tue Jan 27 22:31:04.415 2009   ( 25.01) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  28  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:33:36.496 2009  to  Tue Jan 27 22:34:20.591 2009   ( 44.09) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  29  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:36:43.810 2009  to  Tue Jan 27 22:36:58.793 2009   ( 14.98) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  30  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:43:16.710 2009  to  Tue Jan 27 22:43:34.938 2009   ( 18.23) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  31  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 22:44:41.660 2009  to  Tue Jan 27 22:45:14.660 2009   ( 33.00) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485923937500000e+04, time 6.450000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  32  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:47:26.982 2009  to  Tue Jan 27 22:47:33.455 2009   (  6.47) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  33  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:07.317 2009  to  Tue Jan 27 22:48:13.829 2009   (  6.51) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  34  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:27.455 2009  to  Tue Jan 27 22:48:38.082 2009   ( 10.63) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  35  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:51.526 2009  to  Tue Jan 27 22:49:03.100 2009   ( 11.57) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  36  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:49:16.650 2009  to  Tue Jan 27 22:49:27.136 2009   ( 10.49) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  37  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:50:21.320 2009  to  Tue Jan 27 22:50:27.836 2009   (  6.52) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  38  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:50:41.885 2009  to  Tue Jan 27 22:50:49.406 2009   (  7.52) secs
                    IIF Guide command started for right LBC, coord1 7.100699124291074e-07, coord2 1.207186578512798e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

  39  FAILED    IIF        command.moveFocus                                             Tue Jan 27 22:51:14.047 2009  to  Tue Jan 27 22:51:34.679 2009   ( 20.63) secs
                    IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

  40  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 23:10:02.671 2009  to  Tue Jan 27 23:11:30.503 2009   ( 87.83) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485925697916667e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  41  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:11:31.211 2009  to  Tue Jan 27 23:12:24.645 2009   ( 53.43) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  42  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 23:28:39.273 2009  to  Tue Jan 27 23:29:02.050 2009   ( 22.78) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485926990740740e+04, time 4.850000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  43  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:29:03.483 2009  to  Tue Jan 27 23:29:38.837 2009   ( 35.35) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  44  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:32:17.436 2009  to  Tue Jan 27 23:32:38.756 2009   ( 21.32) secs
                    IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

  45  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:44:04.715 2009  to  Tue Jan 27 23:44:46.075 2009   ( 41.36) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  46  FAILED    IIF        command.preset.(TRACK)                                        Wed Jan 28 05:46:42.405 2009  to  Wed Jan 28 05:48:54.812 2009   (132.41) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485953244212963e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  47  FAILED    IIF        command.moveFocus                                             Wed Jan 28 05:48:55.181 2009  to  Wed Jan 28 05:50:26.701 2009   ( 91.52) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     chiller.command.select . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     chiller.controlValve.command.resetAlarm. . . . . . . . . . . .                                   100.0 %                                7           
                                                                                                   
     chiller.pump.command.on. . . . . . . . . . . . . . . . . . . .                                   100.0 %                     4                      
                                                                                                   
     chiller.pump.command.setState. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     hydraulicBearing.command.setCV0423Position . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   
     hydraulicBearing.command.setState. . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4501                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  9002                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                    18                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     407                      

ECS Events of Interest

   1  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:17:56.276 2009  to  Tue Jan 27 19:17:56.276 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

   2  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:18:05.620 2009  to  Tue Jan 27 19:18:05.620 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

   3  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:18:35.702 2009  to  Tue Jan 27 19:18:35.702 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

   4  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:19:04.887 2009  to  Tue Jan 27 19:19:04.887 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

   5  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:07.088 2009  to  Tue Jan 27 19:23:07.088 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

   6  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:08.928 2009  to  Tue Jan 27 19:23:08.928 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

   7  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:17.043 2009  to  Tue Jan 27 19:23:17.043 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       4                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               1151           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            28
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setMEnc. . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.MEncoders.encodersUsed . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.resetEncoderState. . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setAndArmMEnc. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .       9                      
     MCSPU.Servo.disarmAll. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.MEncoders.resetDone. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.MEncoders.resetAbort . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setMEncs . . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     209                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:01.519 2009  to  Tue Jan 27 17:17:01.519 2009   (  0.00) secs
                    EL bad poly no. 3949: BAD: poly EL = -3.515094e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:04.544 2009  to  Tue Jan 27 17:17:04.544 2009   (  0.00) secs
                    EL bad poly no. 3993: BAD: poly EL = -3.515593e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:07.554 2009  to  Tue Jan 27 17:17:07.554 2009   (  0.00) secs
                    EL bad poly no. 4038: BAD: poly EL = -3.516089e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:10.561 2009  to  Tue Jan 27 17:17:10.561 2009   (  0.00) secs
                    EL bad poly no. 4081: BAD: poly EL = -3.516585e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:13.584 2009  to  Tue Jan 27 17:17:13.584 2009   (  0.00) secs
                    EL bad poly no. 4126: BAD: poly EL = -3.517083e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:16.634 2009  to  Tue Jan 27 17:17:16.634 2009   (  0.00) secs
                    EL bad poly no. 4169: BAD: poly EL = -3.517585e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:19.638 2009  to  Tue Jan 27 17:17:19.638 2009   (  0.00) secs
                    EL bad poly no. 4213: BAD: poly EL = -3.518079e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:22.693 2009  to  Tue Jan 27 17:17:22.693 2009   (  0.00) secs
                    EL bad poly no. 4255: BAD: poly EL = -3.518581e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:25.695 2009  to  Tue Jan 27 17:17:25.695 2009   (  0.00) secs
                    EL bad poly no. 4300: BAD: poly EL = -3.519074e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:28.748 2009  to  Tue Jan 27 17:17:28.748 2009   (  0.00) secs
                    EL bad poly no. 4344: BAD: poly EL = -3.519575e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:31.795 2009  to  Tue Jan 27 17:17:31.795 2009   (  0.00) secs
                    EL bad poly no. 4389: BAD: poly EL = -3.520075e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:34.817 2009  to  Tue Jan 27 17:17:34.817 2009   (  0.00) secs
                    EL bad poly no. 4432: BAD: poly EL = -3.520570e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:37.921 2009  to  Tue Jan 27 17:17:37.921 2009   (  0.00) secs
                    EL bad poly no. 4477: BAD: poly EL = -3.521079e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:40.921 2009  to  Tue Jan 27 17:17:40.921 2009   (  0.00) secs
                    EL bad poly no. 4520: BAD: poly EL = -3.521570e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:43.942 2009  to  Tue Jan 27 17:17:43.942 2009   (  0.00) secs
                    EL bad poly no. 4564: BAD: poly EL = -3.522064e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:47.001 2009  to  Tue Jan 27 17:17:47.001 2009   (  0.00) secs
                    EL bad poly no. 4609: BAD: poly EL = -3.522564e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:50.073 2009  to  Tue Jan 27 17:17:50.073 2009   (  0.00) secs
                    EL bad poly no. 4653: BAD: poly EL = -3.523066e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:53.129 2009  to  Tue Jan 27 17:17:53.129 2009   (  0.00) secs
                    EL bad poly no. 4698: BAD: poly EL = -3.523565e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:56.180 2009  to  Tue Jan 27 17:17:56.180 2009   (  0.00) secs
                    EL bad poly no. 4741: BAD: poly EL = -3.524063e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:59.201 2009  to  Tue Jan 27 17:17:59.201 2009   (  0.00) secs
                    EL bad poly no. 4784: BAD: poly EL = -3.524556e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:02.226 2009  to  Tue Jan 27 17:18:02.226 2009   (  0.00) secs
                    EL bad poly no. 4827: BAD: poly EL = -3.525049e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:05.260 2009  to  Tue Jan 27 17:18:05.260 2009   (  0.00) secs
                    EL bad poly no. 4872: BAD: poly EL = -3.525542e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:08.290 2009  to  Tue Jan 27 17:18:08.290 2009   (  0.00) secs
                    EL bad poly no. 4916: BAD: poly EL = -3.526036e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:11.334 2009  to  Tue Jan 27 17:18:11.334 2009   (  0.00) secs
                    EL bad poly no. 4962: BAD: poly EL = -3.526531e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:14.377 2009  to  Tue Jan 27 17:18:14.377 2009   (  0.00) secs
                    EL bad poly no. 5006: BAD: poly EL = -3.527025e-01 rad. Too low.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.02    0.03    0.02    0.11   100.0 %        657        657                      
                                                                       0.02    0.03    0.02    0.11
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.10    0.06    0.21   100.0 %        385        385                      
                                                                       0.03    0.10    0.06    0.21
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.08    0.08    0.01    0.27   100.0 %         14         14                      
                                                                       0.08    0.08    0.01    0.27
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.04    0.04    0.02    0.42   100.0 %        104        104                      
                                                                       0.04    0.04    0.02    0.42
 *** telescope.command.startTracking. . . . . . . . . . . . . . . .    0.33    0.46    0.00    0.83     0.0 %        104                   104           
                                                                       0.13    0.66    0.52    0.83

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:15:16.240 2009  to  Tue Jan 27 18:30:07.558 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   2  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:15:16.517 2009  to  Tue Jan 27 18:15:16.517 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   3  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:39:27.971 2009  to  Tue Jan 27 18:43:54.195 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:39:28.240 2009  to  Tue Jan 27 18:39:28.240 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:43:54.195 2009  to  Tue Jan 27 18:51:37.211 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   6  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:43:54.474 2009  to  Tue Jan 27 18:43:54.474 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   7  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:02:12.267 2009  to  Tue Jan 27 20:04:25.140 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:02:12.535 2009  to  Tue Jan 27 20:02:12.535 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:04:25.140 2009  to  Tue Jan 27 20:09:53.371 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:04:25.409 2009  to  Tue Jan 27 20:04:25.409 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:55:10.530 2009  to  Tue Jan 27 20:58:37.083 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:55:10.796 2009  to  Tue Jan 27 20:55:10.796 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:58:37.083 2009  to  Tue Jan 27 21:04:49.810 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:58:37.376 2009  to  Tue Jan 27 20:58:37.376 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:04:49.810 2009  to  Tue Jan 27 21:16:38.597 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:04:50.148 2009  to  Tue Jan 27 21:04:50.148 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  17  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:58:28.797 2009  to  Tue Jan 27 22:00:35.756 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  18  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:58:29.067 2009  to  Tue Jan 27 21:58:29.067 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  19  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:10:02.862 2009  to  Tue Jan 27 23:14:56.193 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  20  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:10:03.129 2009  to  Tue Jan 27 23:10:03.129 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  21  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:19:21.311 2009  to  Tue Jan 27 23:21:55.510 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  22  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:19:21.578 2009  to  Tue Jan 27 23:19:21.578 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  23  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:28:39.473 2009  to  Tue Jan 27 23:42:56.560 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  24  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:28:39.743 2009  to  Tue Jan 27 23:28:39.743 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  25  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:49:06.875 2009  to  Tue Jan 27 23:49:06.875 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.01    1.02    1.02    1.05   100.0 %          7          7                      
                                                                       0.01    1.02    1.02    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.52    2.13    2.02    5.04   100.0 %        159        159                      
                                                                       0.52    2.13    2.02    5.04
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    4.17    6.70    2.02   10.03   100.0 %          3          3                      
                                                                       4.17    6.70    2.02   10.03
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    2.51    1.68    0.00    5.04    44.4 %          9          4          5           
                                                                       0.01    5.03    5.02    5.04
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.14   66.13   66.14   100.0 %          4          4                      
                                                                       0.00   66.14   66.13   66.14
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.01    2.02    2.02    2.03   100.0 %          3          3                      
                                                                       0.01    2.02    2.02    2.03
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .    7.86    6.19    0.00  106.24    93.8 %       1558       1461         97           
                                                                       5.87    5.52    2.02  104.22
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .   85.54  199.52   71.23  244.63     0.0 %          4                     4           
                                                                                                   
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.03    0.10    0.05    0.13   100.0 %          4          4                      
                                                                       0.03    0.10    0.05    0.13
     motor.command.overrideLimit. . . . . . . . . . . . . . . . . .    0.00    0.02    0.02    0.02   100.0 %          2          2                      
                                                                       0.00    0.02    0.02    0.02
     motor.command.step . . . . . . . . . . . . . . . . . . . . . .    5.71    3.20    1.02   21.09    66.7 %         12          8          4           
                                                                       6.87    4.28    1.02   21.09

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                          1694
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                           128
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     159                      
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 39           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 39           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      39                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       3                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  5           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                           688
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                           666
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  4           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       4                      
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                  3           
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                            19
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                            10
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                             3
     actuator.setForce.addressError . . . . . . . . . . . . . . . .                  2           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                 55           
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      20                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      20                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      20                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      20                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      20                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      20                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       4                      
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                            12
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor2.panic . . . . . . . . . . . . . . . . .                  1           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  1           
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  4           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:17:12.058 2009  to  Tue Jan 27 18:17:38.220 2009   ( 26.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   2  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:19:43.175 2009  to  Tue Jan 27 18:19:54.211 2009   ( 11.04) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:19:56.217 2009  to  Tue Jan 27 18:20:07.251 2009   ( 11.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:17.250 2009  to  Tue Jan 27 18:20:22.772 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:22.772 2009  to  Tue Jan 27 18:20:22.786 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:24.280 2009  to  Tue Jan 27 18:20:24.280 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:17.644 2009  to  Tue Jan 27 18:22:23.681 2009   (  6.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:44.710 2009  to  Tue Jan 27 18:22:51.741 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:53.255 2009  to  Tue Jan 27 18:23:00.282 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:01.101 2009  to  Tue Jan 27 18:23:06.105 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:06.105 2009  to  Tue Jan 27 18:23:06.160 2009   (  0.06) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  12  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:08.131 2009  to  Tue Jan 27 18:23:08.131 2009   (  0.00) secs
                    Failed event but no Started event
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:31:24.023 2009  to  Tue Jan 27 18:32:32.183 2009   ( 68.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:38:55.675 2009  to  Tue Jan 27 18:39:16.731 2009   ( 21.06) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:50:24.788 2009  to  Tue Jan 27 18:51:25.958 2009   ( 61.17) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:03:42.906 2009  to  Tue Jan 27 19:04:49.067 2009   ( 66.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:10:44.956 2009  to  Tue Jan 27 19:11:09.023 2009   ( 24.07) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:15:51.143 2009  to  Tue Jan 27 19:16:00.232 2009   (  9.09) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  19  FAILED    PMC        VxInterface.close                                             Tue Jan 27 19:48:28.818 2009  to  Tue Jan 27 19:48:28.818 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  20  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 19:48:28.766 2009  to  Tue Jan 27 19:48:28.766 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  21  FAILED    PMC        VxInterface.close                                             Tue Jan 27 19:57:25.708 2009  to  Tue Jan 27 19:57:25.708 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  22  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 19:57:25.686 2009  to  Tue Jan 27 19:57:25.686 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:10:11.305 2009  to  Tue Jan 27 20:10:37.456 2009   ( 26.15) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:10:39.605 2009  to  Tue Jan 27 20:11:19.705 2009   ( 40.10) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:10:55.954 2009  to  Tue Jan 27 20:10:55.954 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  26  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:10:55.940 2009  to  Tue Jan 27 20:10:55.940 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:16:39.829 2009  to  Tue Jan 27 20:16:39.829 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:16:39.814 2009  to  Tue Jan 27 20:16:39.814 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:30:12.307 2009  to  Tue Jan 27 20:30:12.307 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:30:12.293 2009  to  Tue Jan 27 20:30:12.293 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  31  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:32:14.775 2009  to  Tue Jan 27 20:32:14.775 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  32  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:32:14.827 2009  to  Tue Jan 27 20:32:14.827 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:41:30.066 2009  to  Tue Jan 27 20:41:36.094 2009   (  6.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:41:50.327 2009  to  Tue Jan 27 20:42:01.362 2009   ( 11.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  35  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:42:58.818 2009  to  Tue Jan 27 20:43:08.852 2009   ( 10.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  36  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:43:23.396 2009  to  Tue Jan 27 20:43:30.444 2009   (  7.05) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:44:05.887 2009  to  Tue Jan 27 20:44:12.920 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:00:43.236 2009  to  Tue Jan 27 21:00:43.236 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  39  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:00:43.221 2009  to  Tue Jan 27 21:00:43.221 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  40  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:06:56.145 2009  to  Tue Jan 27 21:06:56.145 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  41  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:06:56.128 2009  to  Tue Jan 27 21:06:56.128 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  42  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:49:14.504 2009  to  Tue Jan 27 21:49:14.504 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:49:14.487 2009  to  Tue Jan 27 21:49:14.487 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:52:30.932 2009  to  Tue Jan 27 21:52:30.932 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:52:30.913 2009  to  Tue Jan 27 21:52:30.913 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

  46  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:12:27.595 2009  to  Tue Jan 27 22:12:27.595 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:12:27.580 2009  to  Tue Jan 27 22:12:27.580 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:43:55.415 2009  to  Tue Jan 27 22:43:55.415 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  49  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:43:55.399 2009  to  Tue Jan 27 22:43:55.399 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  50  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:59:11.377 2009  to  Tue Jan 27 22:59:11.377 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:59:11.363 2009  to  Tue Jan 27 22:59:11.363 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  52  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:01:39.641 2009  to  Tue Jan 27 23:01:39.641 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:01:39.674 2009  to  Tue Jan 27 23:01:39.674 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.packetReadError                                   Tue Jan 27 23:01:59.605 2009  to  Tue Jan 27 23:01:59.605 2009   (  0.00) secs
                    left PMC PMCLogger packet read error: 5002

  55  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:01:59.588 2009  to  Tue Jan 27 23:01:59.588 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

  56  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:01:59.925 2009  to  Tue Jan 27 23:01:59.925 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

  57  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:02:00.243 2009  to  Tue Jan 27 23:02:00.243 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

  58  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:02:00.560 2009  to  Tue Jan 27 23:02:00.560 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

  59  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:04:09.333 2009  to  Tue Jan 27 23:04:09.333 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  60  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:04:09.318 2009  to  Tue Jan 27 23:04:09.318 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  61  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:21:45.677 2009  to  Tue Jan 27 23:21:45.677 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:21:45.661 2009  to  Tue Jan 27 23:21:45.661 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  63  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:28:49.049 2009  to  Tue Jan 27 23:28:49.049 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:28:49.035 2009  to  Tue Jan 27 23:28:49.035 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  65  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:34:39.246 2009  to  Tue Jan 27 23:34:39.246 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  66  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:34:39.277 2009  to  Tue Jan 27 23:34:39.277 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  67  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:43:38.300 2009  to  Tue Jan 27 23:43:38.300 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  68  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:43:38.316 2009  to  Tue Jan 27 23:43:38.316 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  69  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:03:44.786 2009  to  Wed Jan 28 00:03:44.786 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  70  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:03:44.800 2009  to  Wed Jan 28 00:03:44.800 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  71  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:07:50.667 2009  to  Wed Jan 28 00:07:50.667 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:07:50.649 2009  to  Wed Jan 28 00:07:50.649 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  73  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:25:31.407 2009  to  Wed Jan 28 00:25:31.407 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:25:31.391 2009  to  Wed Jan 28 00:25:31.391 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  75  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:33:17.940 2009  to  Wed Jan 28 00:33:17.940 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:33:17.921 2009  to  Wed Jan 28 00:33:17.921 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Wed Jan 28 01:11:20.796 2009  to  Wed Jan 28 01:11:20.796 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 01:11:20.779 2009  to  Wed Jan 28 01:11:20.779 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  79  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 02:12:12.527 2009  to  Wed Jan 28 02:12:12.527 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  80  FAILED    PMC        VxInterface.close                                             Wed Jan 28 02:12:12.544 2009  to  Wed Jan 28 02:12:12.544 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  81  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:25.930 2009  to  Wed Jan 28 05:50:25.930 2009   (  0.00) secs
                    left PMC Actuator 215 set force read error: -3

  82  FAILED    PMC        mirror.panic                                                  Wed Jan 28 05:50:25.892 2009  to  Wed Jan 28 05:50:25.892 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

  83  FAILED    PMC        actuator.setForce.addressError                                Wed Jan 28 05:50:28.030 2009  to  Wed Jan 28 05:50:28.030 2009   (  0.00) secs
                    left PMC Actuator 119 set force bad return: 179 instead of 3

  84  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:28.061 2009  to  Wed Jan 28 05:50:28.061 2009   (  0.00) secs
                    left PMC Actuator 128 set force read error: -3

  85  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.339 2009  to  Wed Jan 28 05:50:28.339 2009   (  0.00) secs
                    left PMC Actuator 242 has been reset

  86  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.384 2009  to  Wed Jan 28 05:50:28.384 2009   (  0.00) secs
                    left PMC Actuator 302 has been reset

  87  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.407 2009  to  Wed Jan 28 05:50:28.407 2009   (  0.00) secs
                    left PMC Actuator 311 has been reset

  88  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.421 2009  to  Wed Jan 28 05:50:28.421 2009   (  0.00) secs
                    left PMC Actuator 315 has been reset

  89  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.442 2009  to  Wed Jan 28 05:50:28.442 2009   (  0.00) secs
                    left PMC Actuator 328 has been reset

  90  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.457 2009  to  Wed Jan 28 05:50:28.457 2009   (  0.00) secs
                    left PMC Actuator 336 has been reset

  91  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.493 2009  to  Wed Jan 28 05:50:28.493 2009   (  0.00) secs
                    left PMC Actuator 342 has been reset

  92  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.764 2009  to  Wed Jan 28 05:50:28.764 2009   (  0.00) secs
                    left PMC Actuator 243 has been reset

  93  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.779 2009  to  Wed Jan 28 05:50:28.779 2009   (  0.00) secs
                    left PMC Actuator 217 has been reset

  94  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.799 2009  to  Wed Jan 28 05:50:28.799 2009   (  0.00) secs
                    left PMC Actuator 226 has been reset

  95  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.815 2009  to  Wed Jan 28 05:50:28.815 2009   (  0.00) secs
                    left PMC Actuator 237 has been reset

  96  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.829 2009  to  Wed Jan 28 05:50:28.829 2009   (  0.00) secs
                    left PMC Actuator 241 has been reset

  97  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.849 2009  to  Wed Jan 28 05:50:28.849 2009   (  0.00) secs
                    left PMC Actuator 303 has been reset

  98  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.862 2009  to  Wed Jan 28 05:50:28.862 2009   (  0.00) secs
                    left PMC Actuator 216 has been reset

  99  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.892 2009  to  Wed Jan 28 05:50:28.892 2009   (  0.00) secs
                    left PMC Actuator 234 has been reset

 100  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.913 2009  to  Wed Jan 28 05:50:28.913 2009   (  0.00) secs
                    left PMC Actuator 239 has been reset

 101  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.930 2009  to  Wed Jan 28 05:50:28.930 2009   (  0.00) secs
                    left PMC Actuator 240 has been reset

 102  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.945 2009  to  Wed Jan 28 05:50:28.945 2009   (  0.00) secs
                    left PMC Actuator 301 has been reset

 103  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.960 2009  to  Wed Jan 28 05:50:28.960 2009   (  0.00) secs
                    left PMC Actuator 312 has been reset

 104  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.987 2009  to  Wed Jan 28 05:50:28.987 2009   (  0.00) secs
                    left PMC Actuator 233 has been reset

 105  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.000 2009  to  Wed Jan 28 05:50:29.000 2009   (  0.00) secs
                    left PMC Actuator 236 has been reset

 106  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.018 2009  to  Wed Jan 28 05:50:29.018 2009   (  0.00) secs
                    left PMC Actuator 305 has been reset

 107  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.031 2009  to  Wed Jan 28 05:50:29.031 2009   (  0.00) secs
                    left PMC Actuator 309 has been reset

 108  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.047 2009  to  Wed Jan 28 05:50:29.047 2009   (  0.00) secs
                    left PMC Actuator 304 has been reset

 109  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.063 2009  to  Wed Jan 28 05:50:29.063 2009   (  0.00) secs
                    left PMC Actuator 322 has been reset

 110  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:29.476 2009  to  Wed Jan 28 05:50:29.476 2009   (  0.00) secs
                    left PMC Actuator 137 set force read error: -3

 111  FAILED    PMC        actuator.setForce.addressError                                Wed Jan 28 05:50:29.495 2009  to  Wed Jan 28 05:50:29.495 2009   (  0.00) secs
                    left PMC Actuator 207 set force bad return: 255 instead of 6

 112  SEQERROR  PMC        command.recoverPanic                                          Wed Jan 28 05:51:00.906 2009  to  Wed Jan 28 05:51:01.035 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong cell state

 113  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 05:51:01.035 2009  to  Wed Jan 28 05:51:01.051 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong cell state

 114  SEQERROR  PMC        command.recoverPanic                                          Wed Jan 28 05:51:05.932 2009  to  Wed Jan 28 05:51:05.932 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC RecoverPanic Command Complete

 115  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 05:52:26.658 2009  to  Wed Jan 28 05:56:31.292 2009   (244.63) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 116  FAILED    PMC        mirror.panic                                                  Wed Jan 28 05:56:30.598 2009  to  Wed Jan 28 05:56:30.598 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 117  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 05:56:40.488 2009  to  Wed Jan 28 05:56:40.506 2009   (  0.02) secs
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 118  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 05:59:17.686 2009  to  Wed Jan 28 06:03:19.289 2009   (241.60) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 119  FAILED    PMC        mirror.panic                                                  Wed Jan 28 06:03:18.401 2009  to  Wed Jan 28 06:03:18.401 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 120  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:26.772 2009  to  Wed Jan 28 06:03:26.788 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 121  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:26.965 2009  to  Wed Jan 28 06:03:26.980 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 122  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:28.206 2009  to  Wed Jan 28 06:03:28.222 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 123  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 06:06:13.806 2009  to  Wed Jan 28 06:10:14.405 2009   (240.60) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 124  FAILED    PMC        mirror.panic                                                  Wed Jan 28 06:10:13.686 2009  to  Wed Jan 28 06:10:13.686 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 125  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:22.119 2009  to  Wed Jan 28 06:11:23.136 2009   (  1.02) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 126  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:25.234 2009  to  Wed Jan 28 06:11:26.252 2009   (  1.02) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 127  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:28.614 2009  to  Wed Jan 28 06:11:29.689 2009   (  1.08) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 128  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:31.490 2009  to  Wed Jan 28 06:11:32.516 2009   (  1.03) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 129  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 06:14:22.991 2009  to  Wed Jan 28 06:15:34.218 2009   ( 71.23) secs
                    left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

 130  FAILED    PMC        actuator.forceMonitor2.panic                                  Wed Jan 28 06:16:17.406 2009  to  Wed Jan 28 06:16:17.406 2009   (  0.00) secs
                    left PMC Actuator 416 force monitor 2 PANIC! 159.0 lbs, limit is 54.5

 131  FAILED    PMC        VxInterface.packetReadError                                   Wed Jan 28 06:53:54.356 2009  to  Wed Jan 28 06:53:54.356 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 132  FAILED    PMC        VxInterface.selectTimeout                                     Wed Jan 28 06:53:54.303 2009  to  Wed Jan 28 06:53:54.303 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 133  FAILED    PMC        thermal.badReceive                                            Wed Jan 28 06:53:54.409 2009  to  Wed Jan 28 06:53:54.409 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 134  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:47.675 2009  to  Wed Jan 28 07:00:47.675 2009   (  0.00) secs
                    left PMC Actuator 323 force monitor 1 PANIC! 3.5 lbs, limit is -121.2

 135  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:48.986 2009  to  Wed Jan 28 07:00:48.986 2009   (  0.00) secs
                    left PMC Actuator 111 force monitor 1 PANIC! -318.2 lbs, limit is -113.2

 136  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:49.051 2009  to  Wed Jan 28 07:00:49.051 2009   (  0.00) secs
                    left PMC Actuator 316 force monitor 1 PANIC! 24.0 lbs, limit is -122.3

 137  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:51.619 2009  to  Wed Jan 28 07:00:51.619 2009   (  0.00) secs
                    left PMC Actuator 437 force monitor 1 PANIC! -19.2 lbs, limit is -126.9
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
 *** command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    5.61    5.50    0.22   69.01    94.4 %        916        865         51           
                                                                       4.78    5.07    0.22   44.40
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    8.76    7.19    0.19   91.39    96.8 %        471        456         15           
                                                                       6.32    6.41    2.14   54.56
 *** command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    5.61    5.54    0.25   69.09    94.4 %        916        865         51           
                                                                       4.78    5.11    0.25   44.53
 *** primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    6.20    5.59    0.15   68.92    94.3 %        924        871         53           
                                                                       4.91    5.05    0.15   43.47
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    7.86    6.27    0.00  106.33    93.8 %       1558       1461         97           
                                                                       5.87    5.60    2.07  104.29
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.04    2.09    2.07    2.14   100.0 %          3          3                      
                                                                       0.04    2.09    2.07    2.14
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    4.18    6.76    2.07   10.09   100.0 %          3          3                      
                                                                       4.18    6.76    2.07   10.09
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.05    0.06    0.03    0.38   100.0 %        389        389                      
                                                                       0.05    0.06    0.03    0.38
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    5.72    9.29    5.25   13.34     0.0 %          2                     2           
                                                                                                   
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    8.76    7.13    0.11   91.34    96.8 %        471        456         15           
                                                                       6.32    6.36    2.10   54.38
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.00    0.02    0.02    0.03   100.0 %          8          8                      
                                                                       0.00    0.02    0.02    0.03
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.03    0.02    0.01    0.82   100.0 %        924        924                      
                                                                       0.03    0.02    0.01    0.82

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .              32857           

PSF Events of Interest

   1  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:17:11.891 2009  to  Tue Jan 27 18:17:38.320 2009   ( 26.43) secs
                    left PSF SetInstrumentOffsets failed

   2  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:17:11.943 2009  to  Tue Jan 27 18:17:38.301 2009   ( 26.36) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:17:11.995 2009  to  Tue Jan 27 18:17:38.265 2009   ( 26.27) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   4  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:19:43.146 2009  to  Tue Jan 27 18:19:54.239 2009   ( 11.09) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   5  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:19:45.359 2009  to  Tue Jan 27 18:19:45.359 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02

   6  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:19:45.627 2009  to  Tue Jan 27 18:19:45.627 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:19:56.193 2009  to  Tue Jan 27 18:20:07.284 2009   ( 11.09) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   8  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:01.617 2009  to  Tue Jan 27 18:20:01.617 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

   9  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:01.838 2009  to  Tue Jan 27 18:20:01.838 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

  10  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:02.069 2009  to  Tue Jan 27 18:20:02.069 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

  11  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:06.168 2009  to  Tue Jan 27 18:20:06.168 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02

  12  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:06.401 2009  to  Tue Jan 27 18:20:06.401 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:11.489 2009  to  Tue Jan 27 18:20:11.489 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4434280e-04 -5.6505203e-04 3.3184886e-04 -1.6354942e-01 -8.6364746e-03 4.9529791e-02

  14  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:11.754 2009  to  Tue Jan 27 18:20:11.754 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4434280e-04 -5.6505203e-04 3.3184886e-04 -1.6354942e-01 -8.6364746e-03 4.9529791e-02

  15  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:17.225 2009  to  Tue Jan 27 18:20:22.750 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:20:22.701 2009  to  Tue Jan 27 18:20:22.891 2009   (  0.19) secs
                    right PSF primary mirror setLocalOffsets started
                    left PSF SetInstrumentOffsets failed

  17  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:22.750 2009  to  Tue Jan 27 18:20:22.818 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  18  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:20:22.730 2009  to  Tue Jan 27 18:20:22.841 2009   (  0.11) secs
                    right PSF SetInstrumentOffsets started
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  19  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:24.310 2009  to  Tue Jan 27 18:20:24.310 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  20  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:22:17.474 2009  to  Tue Jan 27 18:22:23.750 2009   (  6.28) secs
                    left PSF SetInstrumentOffsets failed

  21  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:22:17.527 2009  to  Tue Jan 27 18:22:23.731 2009   (  6.20) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  22  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:17.579 2009  to  Tue Jan 27 18:22:23.711 2009   (  6.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:44.682 2009  to  Tue Jan 27 18:22:51.771 2009   (  7.09) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:53.227 2009  to  Tue Jan 27 18:23:00.314 2009   (  7.09) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:22:59.660 2009  to  Tue Jan 27 18:22:59.660 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03

  26  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:22:59.879 2009  to  Tue Jan 27 18:22:59.879 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:01.073 2009  to  Tue Jan 27 18:23:06.019 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  28  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:23:05.915 2009  to  Tue Jan 27 18:23:06.434 2009   (  0.52) secs
                    left PSF SetInstrumentOffsets failed

  29  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:23:05.967 2009  to  Tue Jan 27 18:23:06.355 2009   (  0.39) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  30  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:06.019 2009  to  Tue Jan 27 18:23:06.274 2009   (  0.26) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  31  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:08.243 2009  to  Tue Jan 27 18:23:08.243 2009   (  0.00) secs
                    Failed event but no Started event
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  32  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:17.900 2009  to  Tue Jan 27 18:30:17.900 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.7201121e-04 -3.2660365e-03 1.8042326e-03 1.2414110e-01 -5.0886154e-02 -7.8897983e-02

  33  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.122 2009  to  Tue Jan 27 18:30:18.122 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  34  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.344 2009  to  Tue Jan 27 18:30:18.344 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  35  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.566 2009  to  Tue Jan 27 18:30:18.566 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  36  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.791 2009  to  Tue Jan 27 18:30:18.791 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.4038421e-03 -6.9525242e-03 -6.4730644e-05 2.2847402e-01 5.0724030e-02 -1.2297395e-01

  37  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.047 2009  to  Tue Jan 27 18:30:19.047 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.4038421e-03 -6.9525242e-03 -6.4730644e-05 2.2847402e-01 5.0724030e-02 -1.2297395e-01

  38  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.269 2009  to  Tue Jan 27 18:30:19.269 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  39  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.488 2009  to  Tue Jan 27 18:30:19.488 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  40  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.708 2009  to  Tue Jan 27 18:30:19.708 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  41  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.929 2009  to  Tue Jan 27 18:30:19.929 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.5513081e-03 -1.1774957e-02 -2.3502111e-03 3.9886177e-01 1.0569191e-01 -2.1203795e-01

  42  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.151 2009  to  Tue Jan 27 18:30:20.151 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.7036613e-03 -1.3257921e-02 -2.5362074e-03 4.3391025e-01 4.6016693e-02 -2.2335601e-01

  43  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.381 2009  to  Tue Jan 27 18:30:20.381 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.7036613e-03 -1.3257921e-02 -2.5362074e-03 4.3391025e-01 4.6016693e-02 -2.2335601e-01

  44  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.599 2009  to  Tue Jan 27 18:30:20.599 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1753704e-03 -1.4211655e-02 -1.9569397e-03 4.8072827e-01 7.7863693e-02 -2.5312388e-01

  45  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.833 2009  to  Tue Jan 27 18:30:20.833 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1753704e-03 -1.4211655e-02 -1.9569397e-03 4.8072827e-01 7.7863693e-02 -2.5312388e-01

  46  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:31:23.970 2009  to  Tue Jan 27 18:32:32.250 2009   ( 68.28) secs
                    left PSF SetInstrumentOffsets failed

  47  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:31:23.999 2009  to  Tue Jan 27 18:32:32.213 2009   ( 68.21) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  48  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:31:23.984 2009  to  Tue Jan 27 18:32:32.232 2009   ( 68.25) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  49  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 18:38:22.645 2009  to  Tue Jan 27 18:39:16.781 2009   ( 54.14) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  50  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:38:55.652 2009  to  Tue Jan 27 18:39:16.761 2009   ( 21.11) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 18:50:24.563 2009  to  Tue Jan 27 18:51:26.018 2009   ( 61.46) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:50:24.722 2009  to  Tue Jan 27 18:51:25.988 2009   ( 61.27) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  53  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:03:40.142 2009  to  Tue Jan 27 19:04:49.155 2009   ( 69.01) secs
                    left PSF ApplyZernikes failed

  54  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:03:40.119 2009  to  Tue Jan 27 19:04:49.211 2009   ( 69.09) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  55  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:03:40.196 2009  to  Tue Jan 27 19:04:49.120 2009   ( 68.92) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  56  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:03:42.882 2009  to  Tue Jan 27 19:04:49.101 2009   ( 66.22) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  57  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:10:42.178 2009  to  Tue Jan 27 19:11:09.112 2009   ( 26.93) secs
                    left PSF ApplyZernikes failed

  58  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:10:42.163 2009  to  Tue Jan 27 19:11:09.137 2009   ( 26.97) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  59  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:10:42.227 2009  to  Tue Jan 27 19:11:09.091 2009   ( 26.86) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  60  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:10:44.931 2009  to  Tue Jan 27 19:11:09.074 2009   ( 24.14) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:15:48.340 2009  to  Tue Jan 27 19:16:00.328 2009   ( 11.99) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  62  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:15:48.354 2009  to  Tue Jan 27 19:16:00.310 2009   ( 11.96) secs
                    left PSF ApplyZernikes failed

  63  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:15:48.412 2009  to  Tue Jan 27 19:16:00.291 2009   ( 11.88) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  64  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:15:51.115 2009  to  Tue Jan 27 19:16:00.272 2009   (  9.16) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  65  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:10:11.276 2009  to  Tue Jan 27 20:10:37.489 2009   ( 26.21) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 20:10:39.480 2009  to  Tue Jan 27 20:11:19.782 2009   ( 40.30) secs
                    left PSF SetInstrumentOffsets failed

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:10:39.571 2009  to  Tue Jan 27 20:11:19.743 2009   ( 40.17) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  68  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 20:10:39.553 2009  to  Tue Jan 27 20:11:19.763 2009   ( 40.21) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  69  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:41:29.828 2009  to  Tue Jan 27 20:41:36.158 2009   (  6.33) secs
                    left PSF ApplyZernikes failed

  70  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:41:29.810 2009  to  Tue Jan 27 20:41:36.179 2009   (  6.37) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  71  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:41:29.879 2009  to  Tue Jan 27 20:41:36.140 2009   (  6.26) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  72  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:41:30.038 2009  to  Tue Jan 27 20:41:36.122 2009   (  6.08) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  73  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:41:50.066 2009  to  Tue Jan 27 20:42:01.454 2009   ( 11.39) secs
                    left PSF ApplyZernikes failed

  74  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:41:50.052 2009  to  Tue Jan 27 20:42:01.519 2009   ( 11.47) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  75  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:41:50.118 2009  to  Tue Jan 27 20:42:01.425 2009   ( 11.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  76  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:41:50.304 2009  to  Tue Jan 27 20:42:01.401 2009   ( 11.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  77  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:42:58.563 2009  to  Tue Jan 27 20:43:08.959 2009   ( 10.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  78  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:42:58.581 2009  to  Tue Jan 27 20:43:08.940 2009   ( 10.36) secs
                    left PSF ApplyZernikes failed

  79  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:42:58.632 2009  to  Tue Jan 27 20:43:08.915 2009   ( 10.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  80  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:42:58.791 2009  to  Tue Jan 27 20:43:08.887 2009   ( 10.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  81  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:43:23.156 2009  to  Tue Jan 27 20:43:30.513 2009   (  7.36) secs
                    left PSF ApplyZernikes failed

  82  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:43:23.128 2009  to  Tue Jan 27 20:43:30.531 2009   (  7.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  83  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:43:23.208 2009  to  Tue Jan 27 20:43:30.494 2009   (  7.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  84  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:43:23.369 2009  to  Tue Jan 27 20:43:30.475 2009   (  7.11) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  85  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:44:05.649 2009  to  Tue Jan 27 20:44:12.989 2009   (  7.34) secs
                    left PSF ApplyZernikes failed

  86  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:44:05.633 2009  to  Tue Jan 27 20:44:13.006 2009   (  7.37) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  87  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:44:05.703 2009  to  Tue Jan 27 20:44:12.968 2009   (  7.26) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  88  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:44:05.862 2009  to  Tue Jan 27 20:44:12.951 2009   (  7.09) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  89  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 20:47:28.785 2009  to  Tue Jan 27 20:47:45.983 2009   ( 17.20) secs
                    left PSF SetInstrumentOffsets failed

  90  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 20:47:28.800 2009  to  Tue Jan 27 20:47:45.957 2009   ( 17.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  91  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:52:08.738 2009  to  Tue Jan 27 20:52:20.738 2009   ( 12.00) secs
                    left PSF ApplyZernikes failed

  92  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:52:08.725 2009  to  Tue Jan 27 20:52:20.758 2009   ( 12.03) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  93  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:52:08.803 2009  to  Tue Jan 27 20:52:20.720 2009   ( 11.92) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  94  FAILED    PSF        primaryMirror.command.revert                                  Tue Jan 27 20:54:31.315 2009  to  Tue Jan 27 20:54:44.652 2009   ( 13.34) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

  95  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 21:00:28.096 2009  to  Tue Jan 27 21:01:05.173 2009   ( 37.08) secs
                    left PSF ApplyZernikes failed

  96  FAILED    PSF        command.setZernikes                                           Tue Jan 27 21:00:28.080 2009  to  Tue Jan 27 21:01:05.192 2009   ( 37.11) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

  97  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 21:00:28.153 2009  to  Tue Jan 27 21:01:05.156 2009   ( 37.00) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  98  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 21:06:54.452 2009  to  Tue Jan 27 21:07:00.685 2009   (  6.23) secs
                    left PSF SetInstrumentOffsets failed

  99  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 21:06:54.472 2009  to  Tue Jan 27 21:07:00.659 2009   (  6.19) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 100  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 22:20:45.857 2009  to  Tue Jan 27 22:21:19.143 2009   ( 33.29) secs
                    left PSF SetInstrumentOffsets failed

 101  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 22:20:45.873 2009  to  Tue Jan 27 22:21:19.116 2009   ( 33.24) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 102  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:22:39.248 2009  to  Tue Jan 27 22:22:49.657 2009   ( 10.41) secs
                    left PSF ApplyZernikes failed

 103  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:22:39.230 2009  to  Tue Jan 27 22:22:49.677 2009   ( 10.45) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 104  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:22:39.300 2009  to  Tue Jan 27 22:22:49.635 2009   ( 10.34) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 105  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:25:35.581 2009  to  Tue Jan 27 22:25:46.972 2009   ( 11.39) secs
                    left PSF ApplyZernikes failed

 106  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:25:35.568 2009  to  Tue Jan 27 22:25:46.989 2009   ( 11.42) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 107  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:25:35.628 2009  to  Tue Jan 27 22:25:46.953 2009   ( 11.32) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 108  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:26:00.815 2009  to  Tue Jan 27 22:26:08.179 2009   (  7.36) secs
                    left PSF ApplyZernikes failed

 109  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:26:00.799 2009  to  Tue Jan 27 22:26:08.200 2009   (  7.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 110  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:26:00.863 2009  to  Tue Jan 27 22:26:08.159 2009   (  7.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 111  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:26:22.491 2009  to  Tue Jan 27 22:26:32.897 2009   ( 10.41) secs
                    left PSF ApplyZernikes failed

 112  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:26:22.464 2009  to  Tue Jan 27 22:26:32.919 2009   ( 10.46) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 113  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:26:22.586 2009  to  Tue Jan 27 22:26:32.877 2009   ( 10.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 114  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:30:39.444 2009  to  Tue Jan 27 22:31:04.337 2009   ( 24.89) secs
                    left PSF ApplyZernikes failed

 115  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:30:39.431 2009  to  Tue Jan 27 22:31:04.356 2009   ( 24.92) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 116  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:30:39.504 2009  to  Tue Jan 27 22:31:04.316 2009   ( 24.81) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 117  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:33:36.538 2009  to  Tue Jan 27 22:34:20.504 2009   ( 43.97) secs
                    left PSF ApplyZernikes failed

 118  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:33:36.523 2009  to  Tue Jan 27 22:34:20.524 2009   ( 44.00) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 119  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:33:36.589 2009  to  Tue Jan 27 22:34:20.482 2009   ( 43.89) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 120  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:36:43.854 2009  to  Tue Jan 27 22:36:58.712 2009   ( 14.86) secs
                    left PSF ApplyZernikes failed

 121  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:36:43.837 2009  to  Tue Jan 27 22:36:58.732 2009   ( 14.89) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 122  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:36:43.911 2009  to  Tue Jan 27 22:36:58.695 2009   ( 14.78) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 123  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:43:16.751 2009  to  Tue Jan 27 22:43:34.857 2009   ( 18.11) secs
                    left PSF ApplyZernikes failed

 124  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:43:16.737 2009  to  Tue Jan 27 22:43:34.874 2009   ( 18.14) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 125  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:43:16.806 2009  to  Tue Jan 27 22:43:34.840 2009   ( 18.03) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 126  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:47:27.025 2009  to  Tue Jan 27 22:47:33.378 2009   (  6.35) secs
                    left PSF ApplyZernikes failed

 127  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:47:27.010 2009  to  Tue Jan 27 22:47:33.395 2009   (  6.38) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 128  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:47:27.084 2009  to  Tue Jan 27 22:47:33.359 2009   (  6.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 129  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:07.360 2009  to  Tue Jan 27 22:48:13.757 2009   (  6.40) secs
                    left PSF ApplyZernikes failed

 130  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:07.344 2009  to  Tue Jan 27 22:48:13.778 2009   (  6.43) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 131  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:07.438 2009  to  Tue Jan 27 22:48:13.737 2009   (  6.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 132  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:27.498 2009  to  Tue Jan 27 22:48:37.920 2009   ( 10.42) secs
                    left PSF ApplyZernikes failed

 133  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:27.481 2009  to  Tue Jan 27 22:48:37.956 2009   ( 10.47) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 134  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:27.551 2009  to  Tue Jan 27 22:48:37.902 2009   ( 10.35) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 135  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:51.551 2009  to  Tue Jan 27 22:49:03.046 2009   ( 11.50) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 136  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:51.568 2009  to  Tue Jan 27 22:49:03.027 2009   ( 11.46) secs
                    left PSF ApplyZernikes failed

 137  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:51.697 2009  to  Tue Jan 27 22:49:03.007 2009   ( 11.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 138  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:49:16.694 2009  to  Tue Jan 27 22:49:27.061 2009   ( 10.37) secs
                    left PSF ApplyZernikes failed

 139  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:49:16.678 2009  to  Tue Jan 27 22:49:27.088 2009   ( 10.41) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 140  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:49:16.747 2009  to  Tue Jan 27 22:49:27.043 2009   ( 10.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 141  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:50:21.364 2009  to  Tue Jan 27 22:50:27.757 2009   (  6.39) secs
                    left PSF ApplyZernikes failed

 142  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:50:21.347 2009  to  Tue Jan 27 22:50:27.778 2009   (  6.43) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 143  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:50:41.931 2009  to  Tue Jan 27 22:50:49.312 2009   (  7.38) secs
                    left PSF ApplyZernikes failed

 144  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:50:41.913 2009  to  Tue Jan 27 22:50:49.334 2009   (  7.42) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 145  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 22:51:14.070 2009  to  Tue Jan 27 22:51:34.494 2009   ( 20.42) secs
                    left PSF SetInstrumentOffsets failed

 146  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 22:51:14.085 2009  to  Tue Jan 27 22:51:34.413 2009   ( 20.33) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 147  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:11:31.261 2009  to  Tue Jan 27 23:12:24.593 2009   ( 53.33) secs
                    left PSF SetInstrumentOffsets failed

 148  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:11:31.299 2009  to  Tue Jan 27 23:12:24.573 2009   ( 53.27) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 149  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:29:03.507 2009  to  Tue Jan 27 23:29:38.788 2009   ( 35.28) secs
                    left PSF SetInstrumentOffsets failed

 150  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:29:03.524 2009  to  Tue Jan 27 23:29:38.770 2009   ( 35.25) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 151  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:32:17.461 2009  to  Tue Jan 27 23:32:38.695 2009   ( 21.23) secs
                    left PSF SetInstrumentOffsets failed

 152  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:32:17.482 2009  to  Tue Jan 27 23:32:38.675 2009   ( 21.19) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 153  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:44:04.744 2009  to  Tue Jan 27 23:44:46.015 2009   ( 41.27) secs
                    left PSF SetInstrumentOffsets failed

 154  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:44:04.778 2009  to  Tue Jan 27 23:44:45.997 2009   ( 41.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 155  FAILED    PSF        command.setInstrumentOffsets                                  Wed Jan 28 05:48:55.208 2009  to  Wed Jan 28 05:50:26.599 2009   ( 91.39) secs
                    left PSF SetInstrumentOffsets failed

 156  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Jan 28 05:48:55.230 2009  to  Wed Jan 28 05:50:26.568 2009   ( 91.34) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 157  FAILED    PSF        primaryMirror.command.revert                                  Wed Jan 28 06:15:39.086 2009  to  Wed Jan 28 06:15:44.334 2009   (  5.25) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:01.519 2009  to  Tue Jan 27 17:17:01.519 2009   (  0.00) secs
                    EL bad poly no. 3949: BAD: poly EL = -3.515094e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:04.544 2009  to  Tue Jan 27 17:17:04.544 2009   (  0.00) secs
                    EL bad poly no. 3993: BAD: poly EL = -3.515593e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:07.554 2009  to  Tue Jan 27 17:17:07.554 2009   (  0.00) secs
                    EL bad poly no. 4038: BAD: poly EL = -3.516089e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:10.561 2009  to  Tue Jan 27 17:17:10.561 2009   (  0.00) secs
                    EL bad poly no. 4081: BAD: poly EL = -3.516585e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:13.584 2009  to  Tue Jan 27 17:17:13.584 2009   (  0.00) secs
                    EL bad poly no. 4126: BAD: poly EL = -3.517083e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:16.634 2009  to  Tue Jan 27 17:17:16.634 2009   (  0.00) secs
                    EL bad poly no. 4169: BAD: poly EL = -3.517585e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:19.638 2009  to  Tue Jan 27 17:17:19.638 2009   (  0.00) secs
                    EL bad poly no. 4213: BAD: poly EL = -3.518079e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:22.693 2009  to  Tue Jan 27 17:17:22.693 2009   (  0.00) secs
                    EL bad poly no. 4255: BAD: poly EL = -3.518581e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:25.695 2009  to  Tue Jan 27 17:17:25.695 2009   (  0.00) secs
                    EL bad poly no. 4300: BAD: poly EL = -3.519074e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:28.748 2009  to  Tue Jan 27 17:17:28.748 2009   (  0.00) secs
                    EL bad poly no. 4344: BAD: poly EL = -3.519575e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:31.795 2009  to  Tue Jan 27 17:17:31.795 2009   (  0.00) secs
                    EL bad poly no. 4389: BAD: poly EL = -3.520075e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:34.817 2009  to  Tue Jan 27 17:17:34.817 2009   (  0.00) secs
                    EL bad poly no. 4432: BAD: poly EL = -3.520570e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:37.921 2009  to  Tue Jan 27 17:17:37.921 2009   (  0.00) secs
                    EL bad poly no. 4477: BAD: poly EL = -3.521079e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:40.921 2009  to  Tue Jan 27 17:17:40.921 2009   (  0.00) secs
                    EL bad poly no. 4520: BAD: poly EL = -3.521570e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:43.942 2009  to  Tue Jan 27 17:17:43.942 2009   (  0.00) secs
                    EL bad poly no. 4564: BAD: poly EL = -3.522064e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:47.001 2009  to  Tue Jan 27 17:17:47.001 2009   (  0.00) secs
                    EL bad poly no. 4609: BAD: poly EL = -3.522564e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:50.073 2009  to  Tue Jan 27 17:17:50.073 2009   (  0.00) secs
                    EL bad poly no. 4653: BAD: poly EL = -3.523066e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:53.129 2009  to  Tue Jan 27 17:17:53.129 2009   (  0.00) secs
                    EL bad poly no. 4698: BAD: poly EL = -3.523565e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:56.180 2009  to  Tue Jan 27 17:17:56.180 2009   (  0.00) secs
                    EL bad poly no. 4741: BAD: poly EL = -3.524063e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:17:59.201 2009  to  Tue Jan 27 17:17:59.201 2009   (  0.00) secs
                    EL bad poly no. 4784: BAD: poly EL = -3.524556e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:02.226 2009  to  Tue Jan 27 17:18:02.226 2009   (  0.00) secs
                    EL bad poly no. 4827: BAD: poly EL = -3.525049e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:05.260 2009  to  Tue Jan 27 17:18:05.260 2009   (  0.00) secs
                    EL bad poly no. 4872: BAD: poly EL = -3.525542e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:08.290 2009  to  Tue Jan 27 17:18:08.290 2009   (  0.00) secs
                    EL bad poly no. 4916: BAD: poly EL = -3.526036e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:11.334 2009  to  Tue Jan 27 17:18:11.334 2009   (  0.00) secs
                    EL bad poly no. 4962: BAD: poly EL = -3.526531e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Tue Jan 27 17:18:14.377 2009  to  Tue Jan 27 17:18:14.377 2009   (  0.00) secs
                    EL bad poly no. 5006: BAD: poly EL = -3.527025e-01 rad. Too low.

  26  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:15:16.240 2009  to  Tue Jan 27 18:30:07.558 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  27  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:15:16.517 2009  to  Tue Jan 27 18:15:16.517 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  28  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:17:11.846 2009  to  Tue Jan 27 18:17:38.417 2009   ( 26.57) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485905361111111e+04, time 3.460000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  29  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:17:11.891 2009  to  Tue Jan 27 18:17:38.320 2009   ( 26.43) secs
                    left PSF SetInstrumentOffsets failed

  30  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:17:11.943 2009  to  Tue Jan 27 18:17:38.301 2009   ( 26.36) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  31  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:17:11.995 2009  to  Tue Jan 27 18:17:38.265 2009   ( 26.27) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  32  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:17:12.058 2009  to  Tue Jan 27 18:17:38.220 2009   ( 26.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  33  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:19:43.146 2009  to  Tue Jan 27 18:19:54.239 2009   ( 11.09) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  34  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:19:43.175 2009  to  Tue Jan 27 18:19:54.211 2009   ( 11.04) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  35  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:19:45.359 2009  to  Tue Jan 27 18:19:45.359 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02

  36  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:19:45.627 2009  to  Tue Jan 27 18:19:45.627 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:19:56.193 2009  to  Tue Jan 27 18:20:07.284 2009   ( 11.09) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:19:56.217 2009  to  Tue Jan 27 18:20:07.251 2009   ( 11.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  39  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:01.617 2009  to  Tue Jan 27 18:20:01.617 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

  40  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:01.838 2009  to  Tue Jan 27 18:20:01.838 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

  41  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:02.069 2009  to  Tue Jan 27 18:20:02.069 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.1073351e-03 3.1709671e-05 5.1492453e-04 -1.5011024e-01 -4.1931152e-02 3.8736701e-02

  42  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:06.168 2009  to  Tue Jan 27 18:20:06.168 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02

  43  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:06.401 2009  to  Tue Jan 27 18:20:06.401 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 1.2689233e-03 -2.6361644e-04 3.3324957e-04 -1.5667534e-01 -2.0195007e-02 2.8445005e-02
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  44  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:11.489 2009  to  Tue Jan 27 18:20:11.489 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4434280e-04 -5.6505203e-04 3.3184886e-04 -1.6354942e-01 -8.6364746e-03 4.9529791e-02

  45  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:20:11.754 2009  to  Tue Jan 27 18:20:11.754 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.4434280e-04 -5.6505203e-04 3.3184886e-04 -1.6354942e-01 -8.6364746e-03 4.9529791e-02

  46  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:17.250 2009  to  Tue Jan 27 18:20:22.772 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  47  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:17.225 2009  to  Tue Jan 27 18:20:22.750 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:20:22.701 2009  to  Tue Jan 27 18:20:22.891 2009   (  0.19) secs
                    right PSF primary mirror setLocalOffsets started
                    left PSF SetInstrumentOffsets failed

  49  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:20:22.674 2009  to  Tue Jan 27 18:20:22.956 2009   (  0.28) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:22.772 2009  to  Tue Jan 27 18:20:22.786 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:22.750 2009  to  Tue Jan 27 18:20:22.818 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  52  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:20:22.730 2009  to  Tue Jan 27 18:20:22.841 2009   (  0.11) secs
                    right PSF SetInstrumentOffsets started
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  53  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:20:24.280 2009  to  Tue Jan 27 18:20:24.280 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  54  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:20:24.310 2009  to  Tue Jan 27 18:20:24.310 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  55  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:22:17.405 2009  to  Tue Jan 27 18:22:23.799 2009   (  6.39) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485905715277778e+04, time 3.500000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  56  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:22:17.474 2009  to  Tue Jan 27 18:22:23.750 2009   (  6.28) secs
                    left PSF SetInstrumentOffsets failed

  57  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:22:17.527 2009  to  Tue Jan 27 18:22:23.731 2009   (  6.20) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:17.579 2009  to  Tue Jan 27 18:22:23.711 2009   (  6.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  59  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:17.644 2009  to  Tue Jan 27 18:22:23.681 2009   (  6.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  60  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:44.710 2009  to  Tue Jan 27 18:22:51.741 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:44.682 2009  to  Tue Jan 27 18:22:51.771 2009   (  7.09) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:22:53.255 2009  to  Tue Jan 27 18:23:00.282 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  63  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:22:53.227 2009  to  Tue Jan 27 18:23:00.314 2009   (  7.09) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  64  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:22:59.660 2009  to  Tue Jan 27 18:22:59.660 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03

  65  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:22:59.879 2009  to  Tue Jan 27 18:22:59.879 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: -1.1842251e-03 8.9114904e-04 -1.2204945e-03 -1.5530586e-01 -4.0493011e-02 -9.5592737e-03
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:01.073 2009  to  Tue Jan 27 18:23:06.019 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  67  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:01.101 2009  to  Tue Jan 27 18:23:06.105 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:23:05.915 2009  to  Tue Jan 27 18:23:06.434 2009   (  0.52) secs
                    left PSF SetInstrumentOffsets failed

  69  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:23:05.845 2009  to  Tue Jan 27 18:23:06.645 2009   (  0.80) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

  70  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:23:05.967 2009  to  Tue Jan 27 18:23:06.355 2009   (  0.39) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  71  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:06.019 2009  to  Tue Jan 27 18:23:06.274 2009   (  0.26) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  72  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:06.105 2009  to  Tue Jan 27 18:23:06.160 2009   (  0.06) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  73  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:23:08.131 2009  to  Tue Jan 27 18:23:08.131 2009   (  0.00) secs
                    Failed event but no Started event
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  74  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:23:08.243 2009  to  Tue Jan 27 18:23:08.243 2009   (  0.00) secs
                    Failed event but no Started event
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  75  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:17.900 2009  to  Tue Jan 27 18:30:17.900 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.7201121e-04 -3.2660365e-03 1.8042326e-03 1.2414110e-01 -5.0886154e-02 -7.8897983e-02

  76  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.122 2009  to  Tue Jan 27 18:30:18.122 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  77  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.344 2009  to  Tue Jan 27 18:30:18.344 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  78  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.566 2009  to  Tue Jan 27 18:30:18.566 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.8524751e-04 -4.1821003e-03 1.2255907e-03 1.7363298e-01 1.8348694e-03 -1.1167768e-01

  79  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:18.791 2009  to  Tue Jan 27 18:30:18.791 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.4038421e-03 -6.9525242e-03 -6.4730644e-05 2.2847402e-01 5.0724030e-02 -1.2297395e-01

  80  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.047 2009  to  Tue Jan 27 18:30:19.047 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -1.4038421e-03 -6.9525242e-03 -6.4730644e-05 2.2847402e-01 5.0724030e-02 -1.2297395e-01

  81  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.269 2009  to  Tue Jan 27 18:30:19.269 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  82  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.488 2009  to  Tue Jan 27 18:30:19.488 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  83  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.708 2009  to  Tue Jan 27 18:30:19.708 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1391196e-03 -9.9471211e-03 -1.3885200e-03 3.2273781e-01 2.9500961e-02 -1.3656852e-01

  84  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:19.929 2009  to  Tue Jan 27 18:30:19.929 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.5513081e-03 -1.1774957e-02 -2.3502111e-03 3.9886177e-01 1.0569191e-01 -2.1203795e-01

  85  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.151 2009  to  Tue Jan 27 18:30:20.151 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.7036613e-03 -1.3257921e-02 -2.5362074e-03 4.3391025e-01 4.6016693e-02 -2.2335601e-01

  86  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.381 2009  to  Tue Jan 27 18:30:20.381 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.7036613e-03 -1.3257921e-02 -2.5362074e-03 4.3391025e-01 4.6016693e-02 -2.2335601e-01

  87  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.599 2009  to  Tue Jan 27 18:30:20.599 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1753704e-03 -1.4211655e-02 -1.9569397e-03 4.8072827e-01 7.7863693e-02 -2.5312388e-01

  88  FAILED    PSF        primaryMirror.positionError                                   Tue Jan 27 18:30:20.833 2009  to  Tue Jan 27 18:30:20.833 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: -3.1753704e-03 -1.4211655e-02 -1.9569397e-03 4.8072827e-01 7.7863693e-02 -2.5312388e-01

  89  FAILED    IIF        command.moveFocus                                             Tue Jan 27 18:31:23.932 2009  to  Tue Jan 27 18:32:32.355 2009   ( 68.42) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  90  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:31:24.023 2009  to  Tue Jan 27 18:32:32.183 2009   ( 68.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  91  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 18:31:23.970 2009  to  Tue Jan 27 18:32:32.250 2009   ( 68.28) secs
                    left PSF SetInstrumentOffsets failed

  92  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:31:23.999 2009  to  Tue Jan 27 18:32:32.213 2009   ( 68.21) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  93  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 18:31:23.984 2009  to  Tue Jan 27 18:32:32.232 2009   ( 68.25) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  94  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 18:38:22.645 2009  to  Tue Jan 27 18:39:16.781 2009   ( 54.14) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  95  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:38:55.675 2009  to  Tue Jan 27 18:39:16.731 2009   ( 21.06) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  96  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:38:55.652 2009  to  Tue Jan 27 18:39:16.761 2009   ( 21.11) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:39:27.971 2009  to  Tue Jan 27 18:43:54.195 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  98  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:39:28.240 2009  to  Tue Jan 27 18:39:28.240 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  99  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:43:54.195 2009  to  Tue Jan 27 18:51:37.211 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 100  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 18:43:54.474 2009  to  Tue Jan 27 18:43:54.474 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 101  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 18:50:24.563 2009  to  Tue Jan 27 18:51:26.018 2009   ( 61.46) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 102  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 18:50:24.722 2009  to  Tue Jan 27 18:51:25.988 2009   ( 61.27) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 103  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 18:50:24.788 2009  to  Tue Jan 27 18:51:25.958 2009   ( 61.17) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 104  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:03:40.142 2009  to  Tue Jan 27 19:04:49.155 2009   ( 69.01) secs
                    left PSF ApplyZernikes failed

 105  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:03:40.119 2009  to  Tue Jan 27 19:04:49.211 2009   ( 69.09) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 106  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:03:40.092 2009  to  Tue Jan 27 19:04:49.427 2009   ( 69.33) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 107  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:03:40.196 2009  to  Tue Jan 27 19:04:49.120 2009   ( 68.92) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 108  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:03:42.906 2009  to  Tue Jan 27 19:04:49.067 2009   ( 66.16) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 109  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:03:42.882 2009  to  Tue Jan 27 19:04:49.101 2009   ( 66.22) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 110  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:10:42.136 2009  to  Tue Jan 27 19:11:09.210 2009   ( 27.07) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 111  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:10:42.178 2009  to  Tue Jan 27 19:11:09.112 2009   ( 26.93) secs
                    left PSF ApplyZernikes failed

 112  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:10:42.163 2009  to  Tue Jan 27 19:11:09.137 2009   ( 26.97) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 113  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:10:42.227 2009  to  Tue Jan 27 19:11:09.091 2009   ( 26.86) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 114  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:10:44.956 2009  to  Tue Jan 27 19:11:09.023 2009   ( 24.07) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 115  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:10:44.931 2009  to  Tue Jan 27 19:11:09.074 2009   ( 24.14) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 116  FAILED    PSF        command.setZernikes                                           Tue Jan 27 19:15:48.340 2009  to  Tue Jan 27 19:16:00.328 2009   ( 11.99) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 117  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 19:15:48.314 2009  to  Tue Jan 27 19:16:00.391 2009   ( 12.08) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 118  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 19:15:48.354 2009  to  Tue Jan 27 19:16:00.310 2009   ( 11.96) secs
                    left PSF ApplyZernikes failed

 119  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 19:15:48.412 2009  to  Tue Jan 27 19:16:00.291 2009   ( 11.88) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 120  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 19:15:51.143 2009  to  Tue Jan 27 19:16:00.232 2009   (  9.09) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 121  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 19:15:51.115 2009  to  Tue Jan 27 19:16:00.272 2009   (  9.16) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 122  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:17:56.276 2009  to  Tue Jan 27 19:17:56.276 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

 123  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:18:05.620 2009  to  Tue Jan 27 19:18:05.620 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

 124  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:18:35.702 2009  to  Tue Jan 27 19:18:35.702 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

 125  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:19:04.887 2009  to  Tue Jan 27 19:19:04.887 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

 126  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:07.088 2009  to  Tue Jan 27 19:23:07.088 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

 127  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:08.928 2009  to  Tue Jan 27 19:23:08.928 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0411

 128  FAILED    ECS        chiller.controlValve.command.resetAlarm                       Tue Jan 27 19:23:17.043 2009  to  Tue Jan 27 19:23:17.043 2009   (  0.00) secs
                    Chiller control valve command reset alarm failed:index CV0410

 129  FAILED    PMC        VxInterface.close                                             Tue Jan 27 19:48:28.818 2009  to  Tue Jan 27 19:48:28.818 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 130  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 19:48:28.766 2009  to  Tue Jan 27 19:48:28.766 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 131  FAILED    PMC        VxInterface.close                                             Tue Jan 27 19:57:25.708 2009  to  Tue Jan 27 19:57:25.708 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 132  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 19:57:25.686 2009  to  Tue Jan 27 19:57:25.686 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 133  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:02:12.267 2009  to  Tue Jan 27 20:04:25.140 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 134  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:02:12.535 2009  to  Tue Jan 27 20:02:12.535 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 135  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:04:25.140 2009  to  Tue Jan 27 20:09:53.371 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 136  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:04:25.409 2009  to  Tue Jan 27 20:04:25.409 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 137  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 20:09:53.170 2009  to  Tue Jan 27 20:10:37.575 2009   ( 44.40) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485913187500000e+04, time 6.450000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 138  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:10:11.305 2009  to  Tue Jan 27 20:10:37.456 2009   ( 26.15) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 139  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:10:11.276 2009  to  Tue Jan 27 20:10:37.489 2009   ( 26.21) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 140  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 20:10:39.480 2009  to  Tue Jan 27 20:11:19.782 2009   ( 40.30) secs
                    left PSF SetInstrumentOffsets failed

 141  FAILED    IIF        command.moveFocus                                             Tue Jan 27 20:10:39.458 2009  to  Tue Jan 27 20:11:19.833 2009   ( 40.38) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

 142  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:10:39.571 2009  to  Tue Jan 27 20:11:19.743 2009   ( 40.17) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 143  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 20:10:39.553 2009  to  Tue Jan 27 20:11:19.763 2009   ( 40.21) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 144  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:10:39.605 2009  to  Tue Jan 27 20:11:19.705 2009   ( 40.10) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 145  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:10:55.954 2009  to  Tue Jan 27 20:10:55.954 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:10:55.940 2009  to  Tue Jan 27 20:10:55.940 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 147  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:16:39.829 2009  to  Tue Jan 27 20:16:39.829 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:16:39.814 2009  to  Tue Jan 27 20:16:39.814 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 149  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:30:12.307 2009  to  Tue Jan 27 20:30:12.307 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 150  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:30:12.293 2009  to  Tue Jan 27 20:30:12.293 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 151  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 20:32:14.775 2009  to  Tue Jan 27 20:32:14.775 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 152  FAILED    PMC        VxInterface.close                                             Tue Jan 27 20:32:14.827 2009  to  Tue Jan 27 20:32:14.827 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 153  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:41:29.828 2009  to  Tue Jan 27 20:41:36.158 2009   (  6.33) secs
                    left PSF ApplyZernikes failed

 154  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:41:29.810 2009  to  Tue Jan 27 20:41:36.179 2009   (  6.37) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 155  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:41:29.780 2009  to  Tue Jan 27 20:41:36.229 2009   (  6.45) secs
                    IIF Guide command started for right LBC, coord1 4.430928058523592e-07, coord2 1.410584253908613e-06, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 156  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:41:29.879 2009  to  Tue Jan 27 20:41:36.140 2009   (  6.26) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 157  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:41:30.066 2009  to  Tue Jan 27 20:41:36.094 2009   (  6.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 158  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:41:30.038 2009  to  Tue Jan 27 20:41:36.122 2009   (  6.08) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 159  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:41:50.024 2009  to  Tue Jan 27 20:42:01.600 2009   ( 11.58) secs
                    IIF Guide command started for right LBC, coord1 4.208968291051059e-07, coord2 3.948105233782860e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 160  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:41:50.066 2009  to  Tue Jan 27 20:42:01.454 2009   ( 11.39) secs
                    left PSF ApplyZernikes failed

 161  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:41:50.052 2009  to  Tue Jan 27 20:42:01.519 2009   ( 11.47) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 162  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:41:50.118 2009  to  Tue Jan 27 20:42:01.425 2009   ( 11.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 163  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:41:50.304 2009  to  Tue Jan 27 20:42:01.401 2009   ( 11.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 164  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:41:50.327 2009  to  Tue Jan 27 20:42:01.362 2009   ( 11.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 165  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:42:58.563 2009  to  Tue Jan 27 20:43:08.959 2009   ( 10.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 166  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:42:58.537 2009  to  Tue Jan 27 20:43:09.022 2009   ( 10.48) secs
                    IIF Guide command started for right LBC, coord1 9.315554847679877e-08, coord2 7.537345700986043e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 167  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:42:58.581 2009  to  Tue Jan 27 20:43:08.940 2009   ( 10.36) secs
                    left PSF ApplyZernikes failed

 168  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:42:58.632 2009  to  Tue Jan 27 20:43:08.915 2009   ( 10.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 169  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:42:58.818 2009  to  Tue Jan 27 20:43:08.852 2009   ( 10.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 170  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:42:58.791 2009  to  Tue Jan 27 20:43:08.887 2009   ( 10.10) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 171  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:43:23.098 2009  to  Tue Jan 27 20:43:30.582 2009   (  7.48) secs
                    IIF Guide command started for right LBC, coord1 2.159255546483011e-07, coord2 1.630704474280594e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 172  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:43:23.156 2009  to  Tue Jan 27 20:43:30.513 2009   (  7.36) secs
                    left PSF ApplyZernikes failed

 173  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:43:23.128 2009  to  Tue Jan 27 20:43:30.531 2009   (  7.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 174  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:43:23.208 2009  to  Tue Jan 27 20:43:30.494 2009   (  7.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 175  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:43:23.396 2009  to  Tue Jan 27 20:43:30.444 2009   (  7.05) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 176  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:43:23.369 2009  to  Tue Jan 27 20:43:30.475 2009   (  7.11) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 177  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:44:05.603 2009  to  Tue Jan 27 20:44:13.056 2009   (  7.45) secs
                    IIF Guide command started for right LBC, coord1 4.368154105648823e-07, coord2 6.515685208148007e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 178  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:44:05.649 2009  to  Tue Jan 27 20:44:12.989 2009   (  7.34) secs
                    left PSF ApplyZernikes failed

 179  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:44:05.633 2009  to  Tue Jan 27 20:44:13.006 2009   (  7.37) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 180  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:44:05.703 2009  to  Tue Jan 27 20:44:12.968 2009   (  7.26) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 181  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Tue Jan 27 20:44:05.862 2009  to  Tue Jan 27 20:44:12.951 2009   (  7.09) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 182  FAILED    PMC        mirror.command.goToPosition.absolute                          Tue Jan 27 20:44:05.887 2009  to  Tue Jan 27 20:44:12.920 2009   (  7.03) secs
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 183  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 20:47:28.785 2009  to  Tue Jan 27 20:47:45.983 2009   ( 17.20) secs
                    left PSF SetInstrumentOffsets failed

 184  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 20:47:28.800 2009  to  Tue Jan 27 20:47:45.957 2009   ( 17.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 185  FAILED    IIF        command.moveFocus                                             Tue Jan 27 20:47:28.763 2009  to  Tue Jan 27 20:47:46.038 2009   ( 17.28) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 186  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 20:52:08.738 2009  to  Tue Jan 27 20:52:20.738 2009   ( 12.00) secs
                    left PSF ApplyZernikes failed

 187  FAILED    PSF        command.setZernikes                                           Tue Jan 27 20:52:08.725 2009  to  Tue Jan 27 20:52:20.758 2009   ( 12.03) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 188  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 20:52:08.697 2009  to  Tue Jan 27 20:52:20.830 2009   ( 12.13) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 189  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 20:52:08.803 2009  to  Tue Jan 27 20:52:20.720 2009   ( 11.92) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 190  FAILED    PSF        primaryMirror.command.revert                                  Tue Jan 27 20:54:31.315 2009  to  Tue Jan 27 20:54:44.652 2009   ( 13.34) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

 191  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 20:55:10.327 2009  to  Tue Jan 27 20:56:15.103 2009   ( 64.78) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485916332175926e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 192  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:55:10.530 2009  to  Tue Jan 27 20:58:37.083 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 193  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:55:10.796 2009  to  Tue Jan 27 20:55:10.796 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 194  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:58:37.083 2009  to  Tue Jan 27 21:04:49.810 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 195  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 20:58:37.376 2009  to  Tue Jan 27 20:58:37.376 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 196  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 21:00:28.047 2009  to  Tue Jan 27 21:01:05.276 2009   ( 37.23) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: Primary mirror collimation reached limit
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 197  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 21:00:28.096 2009  to  Tue Jan 27 21:01:05.173 2009   ( 37.08) secs
                    left PSF ApplyZernikes failed

 198  FAILED    PSF        command.setZernikes                                           Tue Jan 27 21:00:28.080 2009  to  Tue Jan 27 21:01:05.192 2009   ( 37.11) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 199  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 21:00:28.153 2009  to  Tue Jan 27 21:01:05.156 2009   ( 37.00) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 200  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:00:43.236 2009  to  Tue Jan 27 21:00:43.236 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 201  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:00:43.221 2009  to  Tue Jan 27 21:00:43.221 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 202  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:04:49.810 2009  to  Tue Jan 27 21:16:38.597 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 203  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:04:50.148 2009  to  Tue Jan 27 21:04:50.148 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 204  FAILED    IIF        command.moveFocus                                             Tue Jan 27 21:06:54.430 2009  to  Tue Jan 27 21:07:00.755 2009   (  6.32) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 205  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 21:06:54.452 2009  to  Tue Jan 27 21:07:00.685 2009   (  6.23) secs
                    left PSF SetInstrumentOffsets failed

 206  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 21:06:54.472 2009  to  Tue Jan 27 21:07:00.659 2009   (  6.19) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 207  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:06:56.145 2009  to  Tue Jan 27 21:06:56.145 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 208  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:06:56.128 2009  to  Tue Jan 27 21:06:56.128 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 209  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:49:14.504 2009  to  Tue Jan 27 21:49:14.504 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 210  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:49:14.487 2009  to  Tue Jan 27 21:49:14.487 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 211  FAILED    PMC        VxInterface.close                                             Tue Jan 27 21:52:30.932 2009  to  Tue Jan 27 21:52:30.932 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

 212  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 21:52:30.913 2009  to  Tue Jan 27 21:52:30.913 2009   (  0.00) secs
                    right PMC Hardpoint length error: expected 304, got 96

 213  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:58:28.797 2009  to  Tue Jan 27 22:00:35.756 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 214  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 21:58:29.067 2009  to  Tue Jan 27 21:58:29.067 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 215  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:12:27.595 2009  to  Tue Jan 27 22:12:27.595 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 216  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:12:27.580 2009  to  Tue Jan 27 22:12:27.580 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 217  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 22:20:45.857 2009  to  Tue Jan 27 22:21:19.143 2009   ( 33.29) secs
                    left PSF SetInstrumentOffsets failed

 218  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 22:20:45.873 2009  to  Tue Jan 27 22:21:19.116 2009   ( 33.24) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 219  FAILED    IIF        command.moveFocus                                             Tue Jan 27 22:20:45.832 2009  to  Tue Jan 27 22:21:19.194 2009   ( 33.36) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 0.000000000000000e+00

 220  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:22:39.248 2009  to  Tue Jan 27 22:22:49.657 2009   ( 10.41) secs
                    left PSF ApplyZernikes failed

 221  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:22:39.230 2009  to  Tue Jan 27 22:22:49.677 2009   ( 10.45) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 222  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:22:39.202 2009  to  Tue Jan 27 22:22:49.778 2009   ( 10.58) secs
                    IIF Guide command started for right LBC, coord1 8.917071665295609e-07, coord2 -1.252423106976413e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 223  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:22:39.300 2009  to  Tue Jan 27 22:22:49.635 2009   ( 10.34) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 224  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:25:35.581 2009  to  Tue Jan 27 22:25:46.972 2009   ( 11.39) secs
                    left PSF ApplyZernikes failed

 225  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:25:35.568 2009  to  Tue Jan 27 22:25:46.989 2009   ( 11.42) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 226  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:25:35.541 2009  to  Tue Jan 27 22:25:47.036 2009   ( 11.50) secs
                    IIF Guide command started for right LBC, coord1 3.514235279313115e-07, coord2 8.264102188002629e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 227  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:25:35.628 2009  to  Tue Jan 27 22:25:46.953 2009   ( 11.32) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 228  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:26:00.815 2009  to  Tue Jan 27 22:26:08.179 2009   (  7.36) secs
                    left PSF ApplyZernikes failed

 229  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:26:00.799 2009  to  Tue Jan 27 22:26:08.200 2009   (  7.40) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 230  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:26:00.771 2009  to  Tue Jan 27 22:26:08.255 2009   (  7.48) secs
                    IIF Guide command started for right LBC, coord1 5.246889411120252e-07, coord2 -3.760543879730371e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 231  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:26:00.863 2009  to  Tue Jan 27 22:26:08.159 2009   (  7.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 232  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:26:22.491 2009  to  Tue Jan 27 22:26:32.897 2009   ( 10.41) secs
                    left PSF ApplyZernikes failed

 233  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:26:22.464 2009  to  Tue Jan 27 22:26:32.919 2009   ( 10.46) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 234  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:26:22.436 2009  to  Tue Jan 27 22:26:32.978 2009   ( 10.54) secs
                    IIF Guide command started for right LBC, coord1 -8.208119703094504e-07, coord2 5.657259780562290e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 235  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:26:22.586 2009  to  Tue Jan 27 22:26:32.877 2009   ( 10.29) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 236  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 22:27:51.063 2009  to  Tue Jan 27 22:28:14.057 2009   ( 22.99) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485922768518519e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 237  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:30:39.444 2009  to  Tue Jan 27 22:31:04.337 2009   ( 24.89) secs
                    left PSF ApplyZernikes failed

 238  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:30:39.431 2009  to  Tue Jan 27 22:31:04.356 2009   ( 24.92) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 239  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:30:39.404 2009  to  Tue Jan 27 22:31:04.415 2009   ( 25.01) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 240  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:30:39.504 2009  to  Tue Jan 27 22:31:04.316 2009   ( 24.81) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 241  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:33:36.496 2009  to  Tue Jan 27 22:34:20.591 2009   ( 44.09) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 242  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:33:36.538 2009  to  Tue Jan 27 22:34:20.504 2009   ( 43.97) secs
                    left PSF ApplyZernikes failed

 243  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:33:36.523 2009  to  Tue Jan 27 22:34:20.524 2009   ( 44.00) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 244  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:33:36.589 2009  to  Tue Jan 27 22:34:20.482 2009   ( 43.89) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 245  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:36:43.810 2009  to  Tue Jan 27 22:36:58.793 2009   ( 14.98) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 246  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:36:43.854 2009  to  Tue Jan 27 22:36:58.712 2009   ( 14.86) secs
                    left PSF ApplyZernikes failed

 247  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:36:43.837 2009  to  Tue Jan 27 22:36:58.732 2009   ( 14.89) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 248  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:36:43.911 2009  to  Tue Jan 27 22:36:58.695 2009   ( 14.78) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 249  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:43:16.751 2009  to  Tue Jan 27 22:43:34.857 2009   ( 18.11) secs
                    left PSF ApplyZernikes failed

 250  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:43:16.737 2009  to  Tue Jan 27 22:43:34.874 2009   ( 18.14) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 251  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:43:16.710 2009  to  Tue Jan 27 22:43:34.938 2009   ( 18.23) secs
                    IIF SendWavefront command started for right LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Actuator ChangeAllOffsets Command Complete
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 252  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:43:16.806 2009  to  Tue Jan 27 22:43:34.840 2009   ( 18.03) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

 253  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:43:55.415 2009  to  Tue Jan 27 22:43:55.415 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 254  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:43:55.399 2009  to  Tue Jan 27 22:43:55.399 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 255  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 22:44:41.660 2009  to  Tue Jan 27 22:45:14.660 2009   ( 33.00) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485923937500000e+04, time 6.450000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 256  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:47:27.025 2009  to  Tue Jan 27 22:47:33.378 2009   (  6.35) secs
                    left PSF ApplyZernikes failed

 257  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:47:27.010 2009  to  Tue Jan 27 22:47:33.395 2009   (  6.38) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 258  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:47:26.982 2009  to  Tue Jan 27 22:47:33.455 2009   (  6.47) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 259  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:47:27.084 2009  to  Tue Jan 27 22:47:33.359 2009   (  6.28) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 260  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:07.317 2009  to  Tue Jan 27 22:48:13.829 2009   (  6.51) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 261  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:07.360 2009  to  Tue Jan 27 22:48:13.757 2009   (  6.40) secs
                    left PSF ApplyZernikes failed

 262  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:07.344 2009  to  Tue Jan 27 22:48:13.778 2009   (  6.43) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 263  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:07.438 2009  to  Tue Jan 27 22:48:13.737 2009   (  6.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 264  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:27.455 2009  to  Tue Jan 27 22:48:38.082 2009   ( 10.63) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 265  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:27.498 2009  to  Tue Jan 27 22:48:37.920 2009   ( 10.42) secs
                    left PSF ApplyZernikes failed

 266  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:27.481 2009  to  Tue Jan 27 22:48:37.956 2009   ( 10.47) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 267  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:27.551 2009  to  Tue Jan 27 22:48:37.902 2009   ( 10.35) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 268  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:48:51.551 2009  to  Tue Jan 27 22:49:03.046 2009   ( 11.50) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 269  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:48:51.526 2009  to  Tue Jan 27 22:49:03.100 2009   ( 11.57) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 270  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:48:51.568 2009  to  Tue Jan 27 22:49:03.027 2009   ( 11.46) secs
                    left PSF ApplyZernikes failed

 271  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:48:51.697 2009  to  Tue Jan 27 22:49:03.007 2009   ( 11.31) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 272  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:49:16.694 2009  to  Tue Jan 27 22:49:27.061 2009   ( 10.37) secs
                    left PSF ApplyZernikes failed

 273  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:49:16.678 2009  to  Tue Jan 27 22:49:27.088 2009   ( 10.41) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 274  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:49:16.650 2009  to  Tue Jan 27 22:49:27.136 2009   ( 10.49) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 275  FAILED    PSF        primaryMirror.command.adjustMirror                            Tue Jan 27 22:49:16.747 2009  to  Tue Jan 27 22:49:27.043 2009   ( 10.30) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 276  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:50:21.320 2009  to  Tue Jan 27 22:50:27.836 2009   (  6.52) secs
                    IIF SendWavefront command started for left LBC for M1
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 277  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:50:21.364 2009  to  Tue Jan 27 22:50:27.757 2009   (  6.39) secs
                    left PSF ApplyZernikes failed

 278  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:50:21.347 2009  to  Tue Jan 27 22:50:27.778 2009   (  6.43) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 279  FAILED    IIF        command.sendWavefront                                         Tue Jan 27 22:50:41.885 2009  to  Tue Jan 27 22:50:49.406 2009   (  7.52) secs
                    IIF Guide command started for right LBC, coord1 7.100699124291074e-07, coord2 1.207186578512798e-07, rotation angle 0.000000000000000e+00
                    IIF SendWavefront alert for left LBC: left PSF primary mirror Zernike coefficients received
                    IIF SendWavefront alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF SendWavefront command failed for left LBC for M1

 280  FAILED    PSF        command.applyZernikes                                         Tue Jan 27 22:50:41.931 2009  to  Tue Jan 27 22:50:49.312 2009   (  7.38) secs
                    left PSF ApplyZernikes failed

 281  FAILED    PSF        command.setZernikes                                           Tue Jan 27 22:50:41.913 2009  to  Tue Jan 27 22:50:49.334 2009   (  7.42) secs
                    left PSF SetZernikes failed for 28 coefficients to ope M1

 282  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 22:51:14.070 2009  to  Tue Jan 27 22:51:34.494 2009   ( 20.42) secs
                    left PSF SetInstrumentOffsets failed

 283  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 22:51:14.085 2009  to  Tue Jan 27 22:51:34.413 2009   ( 20.33) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 284  FAILED    IIF        command.moveFocus                                             Tue Jan 27 22:51:14.047 2009  to  Tue Jan 27 22:51:34.679 2009   ( 20.63) secs
                    IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

 285  FAILED    PMC        VxInterface.close                                             Tue Jan 27 22:59:11.377 2009  to  Tue Jan 27 22:59:11.377 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 286  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 22:59:11.363 2009  to  Tue Jan 27 22:59:11.363 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 287  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:01:39.641 2009  to  Tue Jan 27 23:01:39.641 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 288  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:01:39.674 2009  to  Tue Jan 27 23:01:39.674 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 289  FAILED    PMC        VxInterface.packetReadError                                   Tue Jan 27 23:01:59.605 2009  to  Tue Jan 27 23:01:59.605 2009   (  0.00) secs
                    left PMC PMCLogger packet read error: 5002

 290  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:01:59.588 2009  to  Tue Jan 27 23:01:59.588 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 80, buffer size = 96

 291  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:01:59.925 2009  to  Tue Jan 27 23:01:59.925 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 60, buffer size = 4

 292  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:02:00.243 2009  to  Tue Jan 27 23:02:00.243 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 40, buffer size = 4

 293  FAILED    PMC        VxInterface.selectTimeout                                     Tue Jan 27 23:02:00.560 2009  to  Tue Jan 27 23:02:00.560 2009   (  0.00) secs
                    left PMC PMCLogger select timed out with bytes to receive = 20, buffer size = 4

 294  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:04:09.333 2009  to  Tue Jan 27 23:04:09.333 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 295  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:04:09.318 2009  to  Tue Jan 27 23:04:09.318 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 296  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 23:10:02.671 2009  to  Tue Jan 27 23:11:30.503 2009   ( 87.83) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485925697916667e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 297  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:10:02.862 2009  to  Tue Jan 27 23:14:56.193 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 298  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:10:03.129 2009  to  Tue Jan 27 23:10:03.129 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 299  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:11:31.211 2009  to  Tue Jan 27 23:12:24.645 2009   ( 53.43) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 300  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:11:31.261 2009  to  Tue Jan 27 23:12:24.593 2009   ( 53.33) secs
                    left PSF SetInstrumentOffsets failed

 301  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:11:31.299 2009  to  Tue Jan 27 23:12:24.573 2009   ( 53.27) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 302  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:19:21.311 2009  to  Tue Jan 27 23:21:55.510 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 303  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:19:21.578 2009  to  Tue Jan 27 23:19:21.578 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 304  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:21:45.677 2009  to  Tue Jan 27 23:21:45.677 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 305  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:21:45.661 2009  to  Tue Jan 27 23:21:45.661 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 306  FAILED    IIF        command.preset.(TRACK)                                        Tue Jan 27 23:28:39.273 2009  to  Tue Jan 27 23:29:02.050 2009   ( 22.78) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485926990740740e+04, time 4.850000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 307  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:28:39.473 2009  to  Tue Jan 27 23:42:56.560 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 308  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:28:39.743 2009  to  Tue Jan 27 23:28:39.743 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 309  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:28:49.049 2009  to  Tue Jan 27 23:28:49.049 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 310  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:28:49.035 2009  to  Tue Jan 27 23:28:49.035 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 311  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:29:03.507 2009  to  Tue Jan 27 23:29:38.788 2009   ( 35.28) secs
                    left PSF SetInstrumentOffsets failed

 312  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:29:03.483 2009  to  Tue Jan 27 23:29:38.837 2009   ( 35.35) secs
                    IIF MoveFocus command started for right LBC for 1.040000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 5.300000000000000e-02

 313  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:29:03.524 2009  to  Tue Jan 27 23:29:38.770 2009   ( 35.25) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 314  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:32:17.461 2009  to  Tue Jan 27 23:32:38.695 2009   ( 21.23) secs
                    left PSF SetInstrumentOffsets failed

 315  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:32:17.436 2009  to  Tue Jan 27 23:32:38.756 2009   ( 21.32) secs
                    IIF MoveFocus command started for left LBC for 4.540000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for 4.540000000000000e-01

 316  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:32:17.482 2009  to  Tue Jan 27 23:32:38.675 2009   ( 21.19) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 317  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:34:39.246 2009  to  Tue Jan 27 23:34:39.246 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 318  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:34:39.277 2009  to  Tue Jan 27 23:34:39.277 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 319  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 27 23:43:38.300 2009  to  Tue Jan 27 23:43:38.300 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 320  FAILED    PMC        VxInterface.close                                             Tue Jan 27 23:43:38.316 2009  to  Tue Jan 27 23:43:38.316 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 321  FAILED    PSF        command.setInstrumentOffsets                                  Tue Jan 27 23:44:04.744 2009  to  Tue Jan 27 23:44:46.015 2009   ( 41.27) secs
                    left PSF SetInstrumentOffsets failed

 322  FAILED    IIF        command.moveFocus                                             Tue Jan 27 23:44:04.715 2009  to  Tue Jan 27 23:44:46.075 2009   ( 41.36) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 323  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Tue Jan 27 23:44:04.778 2009  to  Tue Jan 27 23:44:45.997 2009   ( 41.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 324  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 27 23:49:06.875 2009  to  Tue Jan 27 23:49:06.875 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 325  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:03:44.786 2009  to  Wed Jan 28 00:03:44.786 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 326  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:03:44.800 2009  to  Wed Jan 28 00:03:44.800 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 327  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:07:50.667 2009  to  Wed Jan 28 00:07:50.667 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 328  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:07:50.649 2009  to  Wed Jan 28 00:07:50.649 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 329  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:25:31.407 2009  to  Wed Jan 28 00:25:31.407 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 330  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:25:31.391 2009  to  Wed Jan 28 00:25:31.391 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 331  FAILED    PMC        VxInterface.close                                             Wed Jan 28 00:33:17.940 2009  to  Wed Jan 28 00:33:17.940 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 332  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 00:33:17.921 2009  to  Wed Jan 28 00:33:17.921 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 333  FAILED    PMC        VxInterface.close                                             Wed Jan 28 01:11:20.796 2009  to  Wed Jan 28 01:11:20.796 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 334  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 01:11:20.779 2009  to  Wed Jan 28 01:11:20.779 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 335  FAILED    PMC        VxInterface.lengthError                                       Wed Jan 28 02:12:12.527 2009  to  Wed Jan 28 02:12:12.527 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 336  FAILED    PMC        VxInterface.close                                             Wed Jan 28 02:12:12.544 2009  to  Wed Jan 28 02:12:12.544 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 337  FAILED    IIF        command.preset.(TRACK)                                        Wed Jan 28 05:46:42.405 2009  to  Wed Jan 28 05:48:54.812 2009   (132.41) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485953244212963e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: Primary mirror collimation reached limit
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 338  FAILED    PSF        command.setInstrumentOffsets                                  Wed Jan 28 05:48:55.208 2009  to  Wed Jan 28 05:50:26.599 2009   ( 91.39) secs
                    left PSF SetInstrumentOffsets failed

 339  FAILED    IIF        command.moveFocus                                             Wed Jan 28 05:48:55.181 2009  to  Wed Jan 28 05:50:26.701 2009   ( 91.52) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 340  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Wed Jan 28 05:48:55.230 2009  to  Wed Jan 28 05:50:26.568 2009   ( 91.34) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 341  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:25.930 2009  to  Wed Jan 28 05:50:25.930 2009   (  0.00) secs
                    left PMC Actuator 215 set force read error: -3

 342  FAILED    PMC        mirror.panic                                                  Wed Jan 28 05:50:25.892 2009  to  Wed Jan 28 05:50:25.892 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 343  FAILED    PMC        actuator.setForce.addressError                                Wed Jan 28 05:50:28.030 2009  to  Wed Jan 28 05:50:28.030 2009   (  0.00) secs
                    left PMC Actuator 119 set force bad return: 179 instead of 3

 344  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:28.061 2009  to  Wed Jan 28 05:50:28.061 2009   (  0.00) secs
                    left PMC Actuator 128 set force read error: -3

 345  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.339 2009  to  Wed Jan 28 05:50:28.339 2009   (  0.00) secs
                    left PMC Actuator 242 has been reset

 346  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.384 2009  to  Wed Jan 28 05:50:28.384 2009   (  0.00) secs
                    left PMC Actuator 302 has been reset

 347  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.407 2009  to  Wed Jan 28 05:50:28.407 2009   (  0.00) secs
                    left PMC Actuator 311 has been reset

 348  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.421 2009  to  Wed Jan 28 05:50:28.421 2009   (  0.00) secs
                    left PMC Actuator 315 has been reset

 349  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.442 2009  to  Wed Jan 28 05:50:28.442 2009   (  0.00) secs
                    left PMC Actuator 328 has been reset

 350  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.457 2009  to  Wed Jan 28 05:50:28.457 2009   (  0.00) secs
                    left PMC Actuator 336 has been reset

 351  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.493 2009  to  Wed Jan 28 05:50:28.493 2009   (  0.00) secs
                    left PMC Actuator 342 has been reset

 352  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.764 2009  to  Wed Jan 28 05:50:28.764 2009   (  0.00) secs
                    left PMC Actuator 243 has been reset

 353  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.779 2009  to  Wed Jan 28 05:50:28.779 2009   (  0.00) secs
                    left PMC Actuator 217 has been reset

 354  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.799 2009  to  Wed Jan 28 05:50:28.799 2009   (  0.00) secs
                    left PMC Actuator 226 has been reset

 355  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.815 2009  to  Wed Jan 28 05:50:28.815 2009   (  0.00) secs
                    left PMC Actuator 237 has been reset

 356  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.829 2009  to  Wed Jan 28 05:50:28.829 2009   (  0.00) secs
                    left PMC Actuator 241 has been reset

 357  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.849 2009  to  Wed Jan 28 05:50:28.849 2009   (  0.00) secs
                    left PMC Actuator 303 has been reset

 358  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.862 2009  to  Wed Jan 28 05:50:28.862 2009   (  0.00) secs
                    left PMC Actuator 216 has been reset

 359  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.892 2009  to  Wed Jan 28 05:50:28.892 2009   (  0.00) secs
                    left PMC Actuator 234 has been reset

 360  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.913 2009  to  Wed Jan 28 05:50:28.913 2009   (  0.00) secs
                    left PMC Actuator 239 has been reset

 361  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.930 2009  to  Wed Jan 28 05:50:28.930 2009   (  0.00) secs
                    left PMC Actuator 240 has been reset

 362  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.945 2009  to  Wed Jan 28 05:50:28.945 2009   (  0.00) secs
                    left PMC Actuator 301 has been reset

 363  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.960 2009  to  Wed Jan 28 05:50:28.960 2009   (  0.00) secs
                    left PMC Actuator 312 has been reset

 364  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:28.987 2009  to  Wed Jan 28 05:50:28.987 2009   (  0.00) secs
                    left PMC Actuator 233 has been reset

 365  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.000 2009  to  Wed Jan 28 05:50:29.000 2009   (  0.00) secs
                    left PMC Actuator 236 has been reset

 366  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.018 2009  to  Wed Jan 28 05:50:29.018 2009   (  0.00) secs
                    left PMC Actuator 305 has been reset

 367  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.031 2009  to  Wed Jan 28 05:50:29.031 2009   (  0.00) secs
                    left PMC Actuator 309 has been reset

 368  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.047 2009  to  Wed Jan 28 05:50:29.047 2009   (  0.00) secs
                    left PMC Actuator 304 has been reset

 369  FAILED    PMC        actuator.reset                                                Wed Jan 28 05:50:29.063 2009  to  Wed Jan 28 05:50:29.063 2009   (  0.00) secs
                    left PMC Actuator 322 has been reset

 370  FAILED    PMC        actuator.setForce.readError                                   Wed Jan 28 05:50:29.476 2009  to  Wed Jan 28 05:50:29.476 2009   (  0.00) secs
                    left PMC Actuator 137 set force read error: -3

 371  FAILED    PMC        actuator.setForce.addressError                                Wed Jan 28 05:50:29.495 2009  to  Wed Jan 28 05:50:29.495 2009   (  0.00) secs
                    left PMC Actuator 207 set force bad return: 255 instead of 6

 372  SEQERROR  PMC        command.recoverPanic                                          Wed Jan 28 05:51:00.906 2009  to  Wed Jan 28 05:51:01.035 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong cell state

 373  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 05:51:01.035 2009  to  Wed Jan 28 05:51:01.051 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong cell state

 374  SEQERROR  PMC        command.recoverPanic                                          Wed Jan 28 05:51:05.932 2009  to  Wed Jan 28 05:51:05.932 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC RecoverPanic Command Complete

 375  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 05:52:26.658 2009  to  Wed Jan 28 05:56:31.292 2009   (244.63) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 376  FAILED    PMC        mirror.panic                                                  Wed Jan 28 05:56:30.598 2009  to  Wed Jan 28 05:56:30.598 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 377  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 05:56:40.488 2009  to  Wed Jan 28 05:56:40.506 2009   (  0.02) secs
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 378  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 05:59:17.686 2009  to  Wed Jan 28 06:03:19.289 2009   (241.60) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 379  FAILED    PMC        mirror.panic                                                  Wed Jan 28 06:03:18.401 2009  to  Wed Jan 28 06:03:18.401 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 380  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:26.772 2009  to  Wed Jan 28 06:03:26.788 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 381  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:26.965 2009  to  Wed Jan 28 06:03:26.980 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 382  FAILED    PMC        command.recoverPanic                                          Wed Jan 28 06:03:28.206 2009  to  Wed Jan 28 06:03:28.222 2009   (  0.02) secs
                    left PMC RecoverPanic Command Started
                    left PMC RecoverPanic Command Failed because Wrong mirror state

 383  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 06:06:13.806 2009  to  Wed Jan 28 06:10:14.405 2009   (240.60) secs
                    left PMC Mirror AutoRaise Command Failed because Auto raise failed to complete

 384  FAILED    PMC        mirror.panic                                                  Wed Jan 28 06:10:13.686 2009  to  Wed Jan 28 06:10:13.686 2009   (  0.00) secs
                    left PMC ** PANIC: Hardpoint breakaway

 385  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:22.119 2009  to  Wed Jan 28 06:11:23.136 2009   (  1.02) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 386  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:25.234 2009  to  Wed Jan 28 06:11:26.252 2009   (  1.02) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 387  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:28.614 2009  to  Wed Jan 28 06:11:29.689 2009   (  1.08) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 388  FAILED    PMC        motor.command.step                                            Wed Jan 28 06:11:31.490 2009  to  Wed Jan 28 06:11:32.516 2009   (  1.03) secs
                    left PMC Motor Step Command Failed for Index: 2 and MotorSteps: -1000 becasue Motor state not IDLE

 389  FAILED    PMC        mirror.command.raise.auto                                     Wed Jan 28 06:14:22.991 2009  to  Wed Jan 28 06:15:34.218 2009   ( 71.23) secs
                    left PMC Mirror AutoRaise Command Failed because Chase failed to make tolerance

 390  FAILED    PSF        primaryMirror.command.revert                                  Wed Jan 28 06:15:39.086 2009  to  Wed Jan 28 06:15:44.334 2009   (  5.25) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

 391  FAILED    PMC        actuator.forceMonitor2.panic                                  Wed Jan 28 06:16:17.406 2009  to  Wed Jan 28 06:16:17.406 2009   (  0.00) secs
                    left PMC Actuator 416 force monitor 2 PANIC! 159.0 lbs, limit is 54.5

 392  FAILED    PMC        VxInterface.packetReadError                                   Wed Jan 28 06:53:54.356 2009  to  Wed Jan 28 06:53:54.356 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 393  FAILED    PMC        VxInterface.selectTimeout                                     Wed Jan 28 06:53:54.303 2009  to  Wed Jan 28 06:53:54.303 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 394  FAILED    PMC        thermal.badReceive                                            Wed Jan 28 06:53:54.409 2009  to  Wed Jan 28 06:53:54.409 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 395  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:47.675 2009  to  Wed Jan 28 07:00:47.675 2009   (  0.00) secs
                    left PMC Actuator 323 force monitor 1 PANIC! 3.5 lbs, limit is -121.2

 396  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:48.986 2009  to  Wed Jan 28 07:00:48.986 2009   (  0.00) secs
                    left PMC Actuator 111 force monitor 1 PANIC! -318.2 lbs, limit is -113.2

 397  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:49.051 2009  to  Wed Jan 28 07:00:49.051 2009   (  0.00) secs
                    left PMC Actuator 316 force monitor 1 PANIC! 24.0 lbs, limit is -122.3

 398  FAILED    PMC        actuator.forceMonitor1.panic                                  Wed Jan 28 07:00:51.619 2009  to  Wed Jan 28 07:00:51.619 2009   (  0.00) secs
                    left PMC Actuator 437 force monitor 1 PANIC! -19.2 lbs, limit is -126.9

**********************************************************
    Reporting period ending:   Wed Jan 28 07:46:59.926 2009
********************************************************************************************************