You are here: Foswiki>Software Web>TCSSWReportFile_090125 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jan 25 2009 to Jan 26 2009
 
    Reporting period beginning:   Sun Jan 25 17:15:00.227 2009
    Reporting period ending:      Mon Jan 26 07:47:59.955 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    6.41    1.95    0.00   24.03   100.0 %         14         14                      
                                                                       6.64    2.10    0.02   24.03
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    2.93    0.60    0.16   23.32   100.0 %         62         62                      
                                                                       2.93    0.60    0.16   23.32
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.04    0.10    0.08    0.15   100.0 %          3          3                      
                                                                       0.04    0.10    0.08    0.15
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .   10.27    6.90    0.30   71.57    93.5 %         62         58          4           
                                                                      10.48    7.35    2.21   71.57
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    1.59    5.98    4.14    6.92   100.0 %          3          3                      
                                                                       1.59    5.98    4.14    6.92
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   39.74   53.24   11.18  106.71    75.0 %          4          3          1           
                                                                      21.53   35.42   11.18   52.30
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    9.26   17.94    6.60   33.08   100.0 %         11         11                      
                                                                       9.26   17.94    6.60   33.08

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 26 03:17:48.790 2009  to  Mon Jan 26 03:19:35.505 2009   (106.71) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485742905092592e+04, time 5.850000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

   2  FAILED    IIF        command.moveFocus                                             Mon Jan 26 03:47:21.635 2009  to  Mon Jan 26 03:47:21.979 2009   (  0.34) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485744954861111e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   3  FAILED    IIF        command.moveFocus                                             Mon Jan 26 04:33:48.196 2009  to  Mon Jan 26 04:33:48.687 2009   (  0.49) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485748180555556e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   4  SEQERROR  IIF        command.authorize                                             Mon Jan 26 05:03:32.164 2009  to  Mon Jan 26 05:03:27.166 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Authorize command started for both LBC at prime focus (IIF both side)

   5  SEQERROR  IIF        command.authorize                                             Mon Jan 26 05:03:40.455 2009  to  Mon Jan 26 05:03:40.455 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Authorize command complete for both LBC at prime focus (IIF both side)

   6  FAILED    IIF        command.moveFocus                                             Mon Jan 26 05:37:29.311 2009  to  Mon Jan 26 05:37:29.687 2009   (  0.38) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485752603009259e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   7  FAILED    IIF        command.moveFocus                                             Mon Jan 26 05:55:51.902 2009  to  Mon Jan 26 05:55:52.204 2009   (  0.30) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485753878472222e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4460          1           
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8922                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     3                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    14                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     7                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     158                      
     plc.read.failed. . . . . . . . . . . . . . . . . . . . . . . .                  1           
     plc.writeHS.failed . . . . . . . . . . . . . . . . . . . . . .                  3           
     instrumentCooling.badPMCData . . . . . . . . . . . . . . . . .                  6           
     hydraulicBearing.badPMCData. . . . . . . . . . . . . . . . . .                  6           
     instrumentCooling.badSend. . . . . . . . . . . . . . . . . . .                  6           

ECS Events of Interest

   1  FAILED    ECS        plc.read.failed                                               Sun Jan 25 17:56:00.928 2009  to  Sun Jan 25 17:56:00.928 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :HS

   2  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.928 2009  to  Sun Jan 25 17:56:00.928 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 4.0914200e+01, because PLC Read Failed

   3  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.929 2009  to  Sun Jan 25 17:56:00.929 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 1.7900450e+01, because PLC Read Failed

   4  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.929 2009  to  Sun Jan 25 17:56:00.929 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_RIGHT, value 3.7833126e+01, because PLC Read Failed

   5  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Sun Jan 25 17:56:01.144 2009  to  Sun Jan 25 17:56:01.144 2009   (  0.00) secs
                    Hydraulic bearing command set temperature set point failed:temp -7.8330832e+00

   6  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:24:56.753 2009  to  Mon Jan 26 06:24:56.753 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

   7  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:24:56.788 2009  to  Mon Jan 26 06:24:56.788 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

   8  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:06.854 2009  to  Mon Jan 26 06:25:06.854 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

   9  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:06.888 2009  to  Mon Jan 26 06:25:06.888 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

  10  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:16.966 2009  to  Mon Jan 26 06:25:16.966 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

  11  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:17.019 2009  to  Mon Jan 26 06:25:17.019 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

  12  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:28.113 2009  to  Mon Jan 26 06:25:28.113 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

  13  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:28.197 2009  to  Mon Jan 26 06:25:28.197 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

  14  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:28.166 2009  to  Mon Jan 26 06:25:28.166 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

  15  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:39.280 2009  to  Mon Jan 26 06:25:39.280 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

  16  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:39.269 2009  to  Mon Jan 26 06:25:39.269 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

  17  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:39.292 2009  to  Mon Jan 26 06:25:39.292 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

  18  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:50.341 2009  to  Mon Jan 26 06:25:50.341 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

  19  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:50.365 2009  to  Mon Jan 26 06:25:50.365 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

  20  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:50.353 2009  to  Mon Jan 26 06:25:50.353 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

  21  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:01.419 2009  to  Mon Jan 26 06:26:01.419 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

  22  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:14.652 2009  to  Mon Jan 26 06:26:14.652 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

  23  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:27.558 2009  to  Mon Jan 26 06:26:27.558 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       6                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               4498           
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      38                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      11                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            28
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      10                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             9
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      35                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             1
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       5                      
     MCSPU.AZDrive.hbsNotReady. . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:02.851 2009  to  Sun Jan 25 17:15:02.851 2009   (  0.00) secs
                    EL bad poly no. 662269: BAD: poly EL = -4.867886e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:05.854 2009  to  Sun Jan 25 17:15:05.854 2009   (  0.00) secs
                    EL bad poly no. 662315: BAD: poly EL = -4.867463e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:08.865 2009  to  Sun Jan 25 17:15:08.865 2009   (  0.00) secs
                    EL bad poly no. 662360: BAD: poly EL = -4.867038e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:11.884 2009  to  Sun Jan 25 17:15:11.884 2009   (  0.00) secs
                    EL bad poly no. 662408: BAD: poly EL = -4.866611e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:14.927 2009  to  Sun Jan 25 17:15:14.927 2009   (  0.00) secs
                    EL bad poly no. 662453: BAD: poly EL = -4.866181e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:17.926 2009  to  Sun Jan 25 17:15:17.926 2009   (  0.00) secs
                    EL bad poly no. 662500: BAD: poly EL = -4.865756e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:20.944 2009  to  Sun Jan 25 17:15:20.944 2009   (  0.00) secs
                    EL bad poly no. 662544: BAD: poly EL = -4.865329e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:23.990 2009  to  Sun Jan 25 17:15:23.990 2009   (  0.00) secs
                    EL bad poly no. 662591: BAD: poly EL = -4.864897e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:27.007 2009  to  Sun Jan 25 17:15:27.007 2009   (  0.00) secs
                    EL bad poly no. 662636: BAD: poly EL = -4.864468e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:30.029 2009  to  Sun Jan 25 17:15:30.029 2009   (  0.00) secs
                    EL bad poly no. 662682: BAD: poly EL = -4.864039e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:33.073 2009  to  Sun Jan 25 17:15:33.073 2009   (  0.00) secs
                    EL bad poly no. 662728: BAD: poly EL = -4.863606e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:36.110 2009  to  Sun Jan 25 17:15:36.110 2009   (  0.00) secs
                    EL bad poly no. 662774: BAD: poly EL = -4.863174e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:39.138 2009  to  Sun Jan 25 17:15:39.138 2009   (  0.00) secs
                    EL bad poly no. 662819: BAD: poly EL = -4.862743e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:42.132 2009  to  Sun Jan 25 17:15:42.132 2009   (  0.00) secs
                    EL bad poly no. 662866: BAD: poly EL = -4.862316e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:45.135 2009  to  Sun Jan 25 17:15:45.135 2009   (  0.00) secs
                    EL bad poly no. 662911: BAD: poly EL = -4.861887e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:48.203 2009  to  Sun Jan 25 17:15:48.203 2009   (  0.00) secs
                    EL bad poly no. 662959: BAD: poly EL = -4.861449e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:51.216 2009  to  Sun Jan 25 17:15:51.216 2009   (  0.00) secs
                    EL bad poly no. 663004: BAD: poly EL = -4.861018e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:54.262 2009  to  Sun Jan 25 17:15:54.262 2009   (  0.00) secs
                    EL bad poly no. 663051: BAD: poly EL = -4.860582e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:57.296 2009  to  Sun Jan 25 17:15:57.296 2009   (  0.00) secs
                    EL bad poly no. 663096: BAD: poly EL = -4.860148e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:00.337 2009  to  Sun Jan 25 17:16:00.337 2009   (  0.00) secs
                    EL bad poly no. 663143: BAD: poly EL = -4.859712e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:03.369 2009  to  Sun Jan 25 17:16:03.369 2009   (  0.00) secs
                    EL bad poly no. 663187: BAD: poly EL = -4.859277e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:06.431 2009  to  Sun Jan 25 17:16:06.431 2009   (  0.00) secs
                    EL bad poly no. 663234: BAD: poly EL = -4.858837e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:09.491 2009  to  Sun Jan 25 17:16:09.491 2009   (  0.00) secs
                    EL bad poly no. 663277: BAD: poly EL = -4.858397e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:12.519 2009  to  Sun Jan 25 17:16:12.519 2009   (  0.00) secs
                    EL bad poly no. 663322: BAD: poly EL = -4.857961e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:15.578 2009  to  Sun Jan 25 17:16:15.578 2009   (  0.00) secs
                    EL bad poly no. 663368: BAD: poly EL = -4.857521e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sun Jan 25 19:29:59.503 2009  to  Sun Jan 25 19:29:59.503 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 20:01:57.158 2009  to  Sun Jan 25 20:01:57.158 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:08:39.950 2009  to  Sun Jan 25 21:08:39.950 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:09:25.733 2009  to  Sun Jan 25 21:09:25.733 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:09:44.453 2009  to  Sun Jan 25 21:09:44.453 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:10:13.583 2009  to  Sun Jan 25 21:10:13.583 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:11:59.674 2009  to  Sun Jan 25 21:11:59.674 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  33  FAILED    MCS.MCSPU  MCSPU.AZDrive.hbsNotReady                                     Mon Jan 26 00:42:50.014 2009  to  Mon Jan 26 00:42:50.014 2009   (  0.00) secs
                    Cannot leave IDLE state, because HBS is not ready or shows alarm.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       7
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror.init.started . . . . . . . . . . . . .       3                      
     side[0].tertiary_mirror.moveselabs.started . . . . . . . . . .       4                      
     side[0].tertiary_mirror.deinit.started . . . . . . . . . . . .       1                      
     side[0].tertiary_mirror.sendstring.started . . . . . . . . . .       6                      
     side[0].tertiary_mirror.init.complete. . . . . . . . . . . . .       1                      
     side[0].tertiary_mirror.homesel.started. . . . . . . . . . . .       2                      
     side[0].tertiary_mirror.homesel.failed . . . . . . . . . . . .                  1           
     side[0].tertiary_mirror.sendstring.complete. . . . . . . . . .       5                      
     side[0].tertiary_mirror.homesel.complete . . . . . . . . . . .       1                      
     side[0].tertiary_mirror.error. . . . . . . . . . . . . . . . .                             4
     side[0].tertiary_mirror.homemirror.started . . . . . . . . . .       1                      
     side[0].tertiary_mirror.homemirror.failed. . . . . . . . . . .                  1           
     side[0].tertiary_mirror.moveselabs.complete. . . . . . . . . .       3                      
     side[0].tertiary_mirror.init.failed. . . . . . . . . . . . . .                  1           

OSS Events of Interest

   1  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 19:56:10.065 2009  to  Sun Jan 25 19:56:10.065 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

   2  STARTUP   OSS        startup                                                       Sun Jan 25 20:10:28.426 2009  to  Sun Jan 25 20:10:28.426 2009   (  0.00) secs
                    The oss was started.

   3  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:11:09.201 2009  to  Sun Jan 25 20:11:09.201 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

   4  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:11:11.533 2009  to  Sun Jan 25 20:11:11.533 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] complete

   5  FAILED    OSS        side[0].tertiary_mirror.homesel.failed                        Sun Jan 25 20:13:58.410 2009  to  Sun Jan 25 20:13:58.410 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [homeSel] Umac brake not set.

   6  FAILED    OSS        side[0].tertiary_mirror.homemirror.failed                     Sun Jan 25 20:17:25.257 2009  to  Sun Jan 25 20:17:25.257 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [homeMirror.waitForInPositionAll.isInPositionAll] Open loop

   7  SHUTDOWN  OSS        shutdown                                                      Sun Jan 25 20:29:39.036 2009  to  Sun Jan 25 20:29:39.036 2009   (  0.00) secs
                    The oss was shut down.

   8  STARTUP   OSS        startup                                                       Sun Jan 25 20:43:43.624 2009  to  Sun Jan 25 20:43:43.624 2009   (  0.00) secs
                    The oss was started.

   9  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:44:23.657 2009  to  Sun Jan 25 20:44:23.657 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

  10  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:44:26.077 2009  to  Sun Jan 25 20:44:26.077 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] complete

  11  FAILED    OSS        side[0].tertiary_mirror.init.failed                           Sun Jan 25 20:44:53.363 2009  to  Sun Jan 25 20:44:53.363 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [init.waitForInPositionAll.isInPositionAll] Open loop
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.02    0.03    0.02    0.05   100.0 %          3          3                      
                                                                       0.02    0.03    0.02    0.05
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.11    0.08    0.18   100.0 %         62         62                      
                                                                       0.02    0.11    0.08    0.18
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.02    0.04    0.02    0.06   100.0 %          3          3                      
                                                                       0.02    0.04    0.02    0.06
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.02    0.05    0.03    0.07   100.0 %          4          4                      
                                                                       0.02    0.05    0.03    0.07
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.33    0.48    0.00    0.78   100.0 %          4          4                      
                                                                       0.12    0.64    0.56    0.78

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 26 05:29:28.901 2009  to  Mon Jan 26 05:33:00.867 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   2  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 26 05:29:29.175 2009  to  Mon Jan 26 05:29:29.175 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.06    1.06    1.06   100.0 %          1          1                      
                                                                       0.00    1.06    1.06    1.06
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.41    2.85    2.02    5.06   100.0 %         11         11                      
                                                                       1.41    2.85    2.02    5.06
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    2.97    5.85    2.03   10.07   100.0 %          5          5                      
                                                                       2.97    5.85    2.03   10.07
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00   66.14   66.14   66.14   100.0 %          1          1                      
                                                                       0.00   66.14   66.14   66.14
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.98    0.90    0.00    2.05     0.0 %          6                     6           
                                                                       0.89    1.36    0.18    2.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   14.90   11.79    0.00   97.22    93.0 %        142        132         10           
                                                                      15.22   12.16    2.02   97.22
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  291.75  291.75  291.75   100.0 %          1          1                      
                                                                       0.00  291.75  291.75  291.75
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.09    0.09    0.09   100.0 %          1          1                      
                                                                       0.00    0.09    0.09    0.09
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.02    0.04    0.02    0.06   100.0 %          6          6                      
                                                                       0.02    0.04    0.02    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .       5                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .       5                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .       5                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  8           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .       8                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             9
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             4
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       5                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      11                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            14

PMC Events of Interest

   1  FAILED    PMC        VxInterface.lengthError                                       Sun Jan 25 17:22:39.013 2009  to  Sun Jan 25 17:22:39.013 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   2  FAILED    PMC        VxInterface.close                                             Sun Jan 25 17:22:39.031 2009  to  Sun Jan 25 17:22:39.031 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   3  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 26 01:45:23.240 2009  to  Mon Jan 26 01:45:23.240 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   4  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 26 01:45:23.293 2009  to  Mon Jan 26 01:45:23.293 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

   5  FAILED    PMC        thermal.badReceive                                            Mon Jan 26 01:45:23.345 2009  to  Mon Jan 26 01:45:23.345 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:18:34.782 2009  to  Mon Jan 26 03:19:01.855 2009   ( 27.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 03:43:29.607 2009  to  Mon Jan 26 03:43:29.607 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

   8  FAILED    PMC        VxInterface.close                                             Mon Jan 26 03:43:29.637 2009  to  Mon Jan 26 03:43:29.637 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:46:56.474 2009  to  Mon Jan 26 03:47:21.760 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:47:21.760 2009  to  Mon Jan 26 03:47:21.784 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:47:26.555 2009  to  Mon Jan 26 03:47:26.555 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:55:37.720 2009  to  Mon Jan 26 03:56:04.792 2009   ( 27.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 03:56:04.273 2009  to  Mon Jan 26 03:56:33.171 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  14  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:56:06.228 2009  to  Mon Jan 26 03:56:34.305 2009   ( 28.08) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  15  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 03:56:35.194 2009  to  Mon Jan 26 03:56:35.194 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror ChaseStop Command Complete

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:57:43.428 2009  to  Mon Jan 26 03:57:57.503 2009   ( 14.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:40.467 2009  to  Mon Jan 26 04:33:48.348 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  18  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:48.348 2009  to  Mon Jan 26 04:33:48.373 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  19  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:51.507 2009  to  Mon Jan 26 04:33:51.507 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  20  FAILED    PMC        VxInterface.close                                             Mon Jan 26 04:36:27.563 2009  to  Mon Jan 26 04:36:27.563 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  21  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 04:36:27.544 2009  to  Mon Jan 26 04:36:27.544 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  22  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:44:41.520 2009  to  Mon Jan 26 04:45:02.584 2009   ( 21.06) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  23  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 04:45:01.895 2009  to  Mon Jan 26 04:45:14.805 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:45:03.688 2009  to  Mon Jan 26 04:45:15.730 2009   ( 12.04) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  25  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 04:45:16.827 2009  to  Mon Jan 26 04:45:16.827 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror ChaseStop Command Complete

  26  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 04:47:08.035 2009  to  Mon Jan 26 04:47:08.035 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  27  FAILED    PMC        VxInterface.close                                             Mon Jan 26 04:47:08.087 2009  to  Mon Jan 26 04:47:08.087 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  28  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:17:20.826 2009  to  Mon Jan 26 05:17:25.558 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  29  FAILED    PMC        VxInterface.close                                             Mon Jan 26 05:17:24.384 2009  to  Mon Jan 26 05:17:24.384 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  30  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 05:17:24.365 2009  to  Mon Jan 26 05:17:24.365 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  31  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:17:30.598 2009  to  Mon Jan 26 05:17:30.598 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  32  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:25.968 2009  to  Mon Jan 26 05:37:29.470 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  33  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:29.470 2009  to  Mon Jan 26 05:37:29.498 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  34  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:40.011 2009  to  Mon Jan 26 05:37:40.011 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  35  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:55:47.267 2009  to  Mon Jan 26 05:55:52.013 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  36  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:55:52.013 2009  to  Mon Jan 26 05:55:52.033 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  37  FAILED    PMC        VxInterface.close                                             Mon Jan 26 05:56:28.534 2009  to  Mon Jan 26 05:56:28.534 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  38  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 05:56:28.514 2009  to  Mon Jan 26 05:56:28.514 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  39  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:56:30.367 2009  to  Mon Jan 26 05:56:30.367 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  40  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 06:16:57.931 2009  to  Mon Jan 26 06:16:57.931 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  41  FAILED    PMC        VxInterface.close                                             Mon Jan 26 06:16:57.983 2009  to  Mon Jan 26 06:16:57.983 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  42  FAILED    PMC        VxInterface.close                                             Mon Jan 26 06:19:48.924 2009  to  Mon Jan 26 06:19:48.924 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 06:19:48.904 2009  to  Mon Jan 26 06:19:48.904 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  44  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 26 06:23:04.450 2009  to  Mon Jan 26 06:23:04.450 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  45  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 26 06:23:04.432 2009  to  Mon Jan 26 06:23:04.432 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  46  FAILED    PMC        thermal.badReceive                                            Mon Jan 26 06:23:04.468 2009  to  Mon Jan 26 06:23:04.468 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    9.27   17.80    6.45   32.97   100.0 %         11         11                      
                                                                       9.27   17.80    6.45   32.97
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    9.92    6.44    0.19   71.38    93.5 %         62         58          4           
                                                                      10.12    6.87    2.16   71.38
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    9.26   17.86    6.52   33.01   100.0 %         11         11                      
                                                                       9.26   17.86    6.52   33.01
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    9.80   14.28    2.58   61.17   100.0 %         53         53                      
                                                                       9.80   14.28    2.58   61.17
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   14.90   11.87    0.00   97.29    93.0 %        142        132         10           
                                                                      15.22   12.25    2.08   97.29
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    1.01    0.98    0.00    2.16     0.0 %          6                     6           
                                                                       0.86    1.47    0.33    2.16
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    3.00    5.94    2.10   10.18   100.0 %          5          5                      
                                                                       3.00    5.94    2.10   10.18
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.08    0.07    0.03    0.36   100.0 %         16         16                      
                                                                       0.08    0.07    0.03    0.36
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.12    0.12    0.12   100.0 %          1          1                      
                                                                       0.00    0.12    0.12    0.12
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   35.95   59.46   23.33  107.55    60.0 %          5          3          2           
                                                                      29.91   80.56   48.40  107.55
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .   14.98   19.54    3.13   56.25    83.3 %         12         10          2           
                                                                      16.23   20.82    3.13   56.25
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    9.92    6.38    0.13   71.34    93.5 %         62         58          4           
                                                                      10.12    6.80    2.12   71.34
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.03    0.02    0.06   100.0 %         42         42                      
                                                                       0.01    0.03    0.02    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.03    0.02    0.07   100.0 %         53         53                      
                                                                       0.01    0.03    0.02    0.07

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .              284240           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.227 2009  to  Sun Jan 25 17:15:00.227 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6343485e-03 -5.8795214e-03 2.4241209e-03 1.2965393e-01 -2.4110985e-01 -1.8357670e-01

   2  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.462 2009  to  Sun Jan 25 17:15:00.462 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7770698e-03 -5.5854321e-03 2.6044846e-03 1.1365128e-01 -2.3461533e-01 -1.7309773e-01

   3  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.685 2009  to  Sun Jan 25 17:15:00.685 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7770698e-03 -5.5854321e-03 2.6044846e-03 1.1365128e-01 -2.3461533e-01 -1.7309773e-01

   4  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.915 2009  to  Sun Jan 25 17:15:00.915 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.2960325e-03 -5.8717728e-03 2.6067495e-03 1.5187454e-01 -2.4631882e-01 -1.7323124e-01

   5  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.140 2009  to  Sun Jan 25 17:15:01.140 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.2960325e-03 -5.8717728e-03 2.6067495e-03 1.5187454e-01 -2.4631882e-01 -1.7323124e-01

   6  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.368 2009  to  Sun Jan 25 17:15:01.368 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

   7  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.610 2009  to  Sun Jan 25 17:15:01.610 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

   8  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.866 2009  to  Sun Jan 25 17:15:01.866 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.3320189e-03 -6.5318346e-03 2.6472807e-03 1.3719940e-01 -2.4147606e-01 -1.5022874e-01

   9  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.089 2009  to  Sun Jan 25 17:15:02.089 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.3320189e-03 -6.5318346e-03 2.6472807e-03 1.3719940e-01 -2.4147606e-01 -1.5022874e-01

  10  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.313 2009  to  Sun Jan 25 17:15:02.313 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1618625e-03 -5.6421757e-03 3.0211210e-03 8.9046478e-02 -2.2552872e-01 -1.4949632e-01

  11  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.551 2009  to  Sun Jan 25 17:15:02.551 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1618625e-03 -5.6421757e-03 3.0211210e-03 8.9046478e-02 -2.2552872e-01 -1.4949632e-01

  12  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.775 2009  to  Sun Jan 25 17:15:02.775 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

  13  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.005 2009  to  Sun Jan 25 17:15:03.005 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

  14  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.236 2009  to  Sun Jan 25 17:15:03.236 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  15  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.467 2009  to  Sun Jan 25 17:15:03.467 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  16  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.691 2009  to  Sun Jan 25 17:15:03.691 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  17  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.915 2009  to  Sun Jan 25 17:15:03.915 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1334311e-03 -6.1689615e-03 2.4240017e-03 1.4526749e-01 -2.6818466e-01 -1.6287625e-01

  18  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.142 2009  to  Sun Jan 25 17:15:04.142 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1334311e-03 -6.1689615e-03 2.4240017e-03 1.4526749e-01 -2.6818466e-01 -1.6287625e-01

  19  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.370 2009  to  Sun Jan 25 17:15:04.370 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.9544234e-03 -5.8747530e-03 2.2381544e-03 1.2936974e-01 -2.5124931e-01 -1.5234673e-01

  20  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.595 2009  to  Sun Jan 25 17:15:04.595 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  21  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.817 2009  to  Sun Jan 25 17:15:04.817 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  22  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.043 2009  to  Sun Jan 25 17:15:05.043 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  23  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.270 2009  to  Sun Jan 25 17:15:05.270 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  24  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.493 2009  to  Sun Jan 25 17:15:05.493 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  25  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.715 2009  to  Sun Jan 25 17:15:05.715 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8329363e-03 -6.2425137e-03 2.6473999e-03 1.2158585e-01 -2.1440315e-01 -1.7092919e-01

  26  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:18:34.748 2009  to  Mon Jan 26 03:19:01.925 2009   ( 27.18) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  27  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:46:56.441 2009  to  Mon Jan 26 03:47:21.724 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  28  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 03:47:21.665 2009  to  Mon Jan 26 03:47:21.887 2009   (  0.22) secs
                    left PSF SetInstrumentOffsets failed

  29  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:47:21.724 2009  to  Mon Jan 26 03:47:21.832 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  30  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 03:47:21.692 2009  to  Mon Jan 26 03:47:21.856 2009   (  0.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  31  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:47:26.589 2009  to  Mon Jan 26 03:47:26.589 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  32  FAILED    PSF        primaryMirror.command.revert                                  Mon Jan 26 03:55:32.564 2009  to  Mon Jan 26 03:56:04.853 2009   ( 32.29) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

  33  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:55:37.691 2009  to  Mon Jan 26 03:56:04.826 2009   ( 27.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  34  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 03:56:04.250 2009  to  Mon Jan 26 03:56:33.050 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror chaseStop started

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:56:06.196 2009  to  Mon Jan 26 03:56:34.338 2009   ( 28.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  36  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 03:56:35.231 2009  to  Mon Jan 26 03:56:35.231 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror chaseStop complete

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:57:43.395 2009  to  Mon Jan 26 03:57:57.540 2009   ( 14.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  38  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Mon Jan 26 03:57:43.377 2009  to  Mon Jan 26 03:57:57.564 2009   ( 14.19) secs
                    left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  39  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:40.437 2009  to  Mon Jan 26 04:33:48.298 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 04:33:48.234 2009  to  Mon Jan 26 04:33:48.522 2009   (  0.29) secs
                    left PSF SetInstrumentOffsets failed

  41  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:48.298 2009  to  Mon Jan 26 04:33:48.440 2009   (  0.14) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  42  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 04:33:48.264 2009  to  Mon Jan 26 04:33:48.485 2009   (  0.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  43  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:51.555 2009  to  Mon Jan 26 04:33:51.555 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  44  FAILED    PSF        primaryMirror.command.revert                                  Mon Jan 26 04:44:39.318 2009  to  Mon Jan 26 04:45:02.645 2009   ( 23.33) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

  45  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:44:41.465 2009  to  Mon Jan 26 04:45:02.622 2009   ( 21.16) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  46  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 04:45:01.845 2009  to  Mon Jan 26 04:45:14.780 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror chaseStop started

  47  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Mon Jan 26 04:45:03.640 2009  to  Mon Jan 26 04:45:15.783 2009   ( 12.14) secs
                    left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:45:03.659 2009  to  Mon Jan 26 04:45:15.762 2009   ( 12.10) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 04:45:16.864 2009  to  Mon Jan 26 04:45:16.864 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror chaseStop complete

  50  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:17:20.794 2009  to  Mon Jan 26 05:17:25.536 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  51  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:17:30.642 2009  to  Mon Jan 26 05:17:30.642 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  52  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:25.940 2009  to  Mon Jan 26 05:37:29.443 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 05:37:29.405 2009  to  Mon Jan 26 05:37:29.601 2009   (  0.20) secs
                    left PSF SetInstrumentOffsets failed

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:29.443 2009  to  Mon Jan 26 05:37:29.545 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  55  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 05:37:29.428 2009  to  Mon Jan 26 05:37:29.582 2009   (  0.15) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  56  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:40.042 2009  to  Mon Jan 26 05:37:40.042 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  57  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:55:47.244 2009  to  Mon Jan 26 05:55:51.985 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  58  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 05:55:51.932 2009  to  Mon Jan 26 05:55:52.118 2009   (  0.19) secs
                    left PSF SetInstrumentOffsets failed

  59  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:55:51.985 2009  to  Mon Jan 26 05:55:52.066 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  60  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 05:55:51.958 2009  to  Mon Jan 26 05:55:52.092 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  61  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:56:30.477 2009  to  Mon Jan 26 05:56:30.477 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.227 2009  to  Sun Jan 25 17:15:00.227 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6343485e-03 -5.8795214e-03 2.4241209e-03 1.2965393e-01 -2.4110985e-01 -1.8357670e-01

   2  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.462 2009  to  Sun Jan 25 17:15:00.462 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7770698e-03 -5.5854321e-03 2.6044846e-03 1.1365128e-01 -2.3461533e-01 -1.7309773e-01

   3  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.685 2009  to  Sun Jan 25 17:15:00.685 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7770698e-03 -5.5854321e-03 2.6044846e-03 1.1365128e-01 -2.3461533e-01 -1.7309773e-01

   4  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:00.915 2009  to  Sun Jan 25 17:15:00.915 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.2960325e-03 -5.8717728e-03 2.6067495e-03 1.5187454e-01 -2.4631882e-01 -1.7323124e-01

   5  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.140 2009  to  Sun Jan 25 17:15:01.140 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.2960325e-03 -5.8717728e-03 2.6067495e-03 1.5187454e-01 -2.4631882e-01 -1.7323124e-01

   6  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.368 2009  to  Sun Jan 25 17:15:01.368 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

   7  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.610 2009  to  Sun Jan 25 17:15:01.610 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

   8  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:01.866 2009  to  Sun Jan 25 17:15:01.866 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.3320189e-03 -6.5318346e-03 2.6472807e-03 1.3719940e-01 -2.4147606e-01 -1.5022874e-01

   9  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.089 2009  to  Sun Jan 25 17:15:02.089 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.3320189e-03 -6.5318346e-03 2.6472807e-03 1.3719940e-01 -2.4147606e-01 -1.5022874e-01

  10  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.313 2009  to  Sun Jan 25 17:15:02.313 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1618625e-03 -5.6421757e-03 3.0211210e-03 8.9046478e-02 -2.2552872e-01 -1.4949632e-01

  11  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.551 2009  to  Sun Jan 25 17:15:02.551 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1618625e-03 -5.6421757e-03 3.0211210e-03 8.9046478e-02 -2.2552872e-01 -1.4949632e-01

  12  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:02.775 2009  to  Sun Jan 25 17:15:02.775 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:02.851 2009  to  Sun Jan 25 17:15:02.851 2009   (  0.00) secs
                    EL bad poly no. 662269: BAD: poly EL = -4.867886e-01 rad. Too low.

  14  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.005 2009  to  Sun Jan 25 17:15:03.005 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.5110265e-03 -6.8261623e-03 2.8331280e-03 1.5309715e-01 -2.5841141e-01 -1.6075826e-01

  15  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.236 2009  to  Sun Jan 25 17:15:03.236 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  16  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.467 2009  to  Sun Jan 25 17:15:03.467 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  17  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.691 2009  to  Sun Jan 25 17:15:03.691 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8493425e-03 -6.8339109e-03 2.6504993e-03 1.3087654e-01 -2.5320435e-01 -1.7110372e-01

  18  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:03.915 2009  to  Sun Jan 25 17:15:03.915 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1334311e-03 -6.1689615e-03 2.4240017e-03 1.4526749e-01 -2.6818466e-01 -1.6287625e-01

  19  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.142 2009  to  Sun Jan 25 17:15:04.142 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.1334311e-03 -6.1689615e-03 2.4240017e-03 1.4526749e-01 -2.6818466e-01 -1.6287625e-01

  20  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.370 2009  to  Sun Jan 25 17:15:04.370 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.9544234e-03 -5.8747530e-03 2.2381544e-03 1.2936974e-01 -2.5124931e-01 -1.5234673e-01

  21  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.595 2009  to  Sun Jan 25 17:15:04.595 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  22  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:04.817 2009  to  Sun Jan 25 17:15:04.817 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  23  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.043 2009  to  Sun Jan 25 17:15:05.043 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  24  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.270 2009  to  Sun Jan 25 17:15:05.270 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  25  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.493 2009  to  Sun Jan 25 17:15:05.493 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.6703348e-03 -6.5395832e-03 2.4646521e-03 1.1497879e-01 -2.3626900e-01 -1.6057420e-01

  26  FAILED    PSF        primaryMirror.positionError                                   Sun Jan 25 17:15:05.715 2009  to  Sun Jan 25 17:15:05.715 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 3.8329363e-03 -6.2425137e-03 2.6473999e-03 1.2158585e-01 -2.1440315e-01 -1.7092919e-01

  27  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:05.854 2009  to  Sun Jan 25 17:15:05.854 2009   (  0.00) secs
                    EL bad poly no. 662315: BAD: poly EL = -4.867463e-01 rad. Too low.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:08.865 2009  to  Sun Jan 25 17:15:08.865 2009   (  0.00) secs
                    EL bad poly no. 662360: BAD: poly EL = -4.867038e-01 rad. Too low.

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:11.884 2009  to  Sun Jan 25 17:15:11.884 2009   (  0.00) secs
                    EL bad poly no. 662408: BAD: poly EL = -4.866611e-01 rad. Too low.

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:14.927 2009  to  Sun Jan 25 17:15:14.927 2009   (  0.00) secs
                    EL bad poly no. 662453: BAD: poly EL = -4.866181e-01 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:17.926 2009  to  Sun Jan 25 17:15:17.926 2009   (  0.00) secs
                    EL bad poly no. 662500: BAD: poly EL = -4.865756e-01 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:20.944 2009  to  Sun Jan 25 17:15:20.944 2009   (  0.00) secs
                    EL bad poly no. 662544: BAD: poly EL = -4.865329e-01 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:23.990 2009  to  Sun Jan 25 17:15:23.990 2009   (  0.00) secs
                    EL bad poly no. 662591: BAD: poly EL = -4.864897e-01 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:27.007 2009  to  Sun Jan 25 17:15:27.007 2009   (  0.00) secs
                    EL bad poly no. 662636: BAD: poly EL = -4.864468e-01 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:30.029 2009  to  Sun Jan 25 17:15:30.029 2009   (  0.00) secs
                    EL bad poly no. 662682: BAD: poly EL = -4.864039e-01 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:33.073 2009  to  Sun Jan 25 17:15:33.073 2009   (  0.00) secs
                    EL bad poly no. 662728: BAD: poly EL = -4.863606e-01 rad. Too low.

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:36.110 2009  to  Sun Jan 25 17:15:36.110 2009   (  0.00) secs
                    EL bad poly no. 662774: BAD: poly EL = -4.863174e-01 rad. Too low.

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:39.138 2009  to  Sun Jan 25 17:15:39.138 2009   (  0.00) secs
                    EL bad poly no. 662819: BAD: poly EL = -4.862743e-01 rad. Too low.

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:42.132 2009  to  Sun Jan 25 17:15:42.132 2009   (  0.00) secs
                    EL bad poly no. 662866: BAD: poly EL = -4.862316e-01 rad. Too low.

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:45.135 2009  to  Sun Jan 25 17:15:45.135 2009   (  0.00) secs
                    EL bad poly no. 662911: BAD: poly EL = -4.861887e-01 rad. Too low.

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:48.203 2009  to  Sun Jan 25 17:15:48.203 2009   (  0.00) secs
                    EL bad poly no. 662959: BAD: poly EL = -4.861449e-01 rad. Too low.

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:51.216 2009  to  Sun Jan 25 17:15:51.216 2009   (  0.00) secs
                    EL bad poly no. 663004: BAD: poly EL = -4.861018e-01 rad. Too low.

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:54.262 2009  to  Sun Jan 25 17:15:54.262 2009   (  0.00) secs
                    EL bad poly no. 663051: BAD: poly EL = -4.860582e-01 rad. Too low.

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:15:57.296 2009  to  Sun Jan 25 17:15:57.296 2009   (  0.00) secs
                    EL bad poly no. 663096: BAD: poly EL = -4.860148e-01 rad. Too low.

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:00.337 2009  to  Sun Jan 25 17:16:00.337 2009   (  0.00) secs
                    EL bad poly no. 663143: BAD: poly EL = -4.859712e-01 rad. Too low.

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:03.369 2009  to  Sun Jan 25 17:16:03.369 2009   (  0.00) secs
                    EL bad poly no. 663187: BAD: poly EL = -4.859277e-01 rad. Too low.

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:06.431 2009  to  Sun Jan 25 17:16:06.431 2009   (  0.00) secs
                    EL bad poly no. 663234: BAD: poly EL = -4.858837e-01 rad. Too low.

  48  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:09.491 2009  to  Sun Jan 25 17:16:09.491 2009   (  0.00) secs
                    EL bad poly no. 663277: BAD: poly EL = -4.858397e-01 rad. Too low.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:12.519 2009  to  Sun Jan 25 17:16:12.519 2009   (  0.00) secs
                    EL bad poly no. 663322: BAD: poly EL = -4.857961e-01 rad. Too low.

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sun Jan 25 17:16:15.578 2009  to  Sun Jan 25 17:16:15.578 2009   (  0.00) secs
                    EL bad poly no. 663368: BAD: poly EL = -4.857521e-01 rad. Too low.

  51  FAILED    PMC        VxInterface.lengthError                                       Sun Jan 25 17:22:39.013 2009  to  Sun Jan 25 17:22:39.013 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.close                                             Sun Jan 25 17:22:39.031 2009  to  Sun Jan 25 17:22:39.031 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  53  FAILED    ECS        plc.read.failed                                               Sun Jan 25 17:56:00.928 2009  to  Sun Jan 25 17:56:00.928 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :HS

  54  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.928 2009  to  Sun Jan 25 17:56:00.928 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 4.0914200e+01, because PLC Read Failed

  55  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.929 2009  to  Sun Jan 25 17:56:00.929 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component HB_TEMP_SETPNT, value 1.7900450e+01, because PLC Read Failed

  56  FAILED    ECS        plc.writeHS.failed                                            Sun Jan 25 17:56:00.929 2009  to  Sun Jan 25 17:56:00.929 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_RIGHT, value 3.7833126e+01, because PLC Read Failed

  57  FAILED    ECS        hydraulicBearing.command.setTemperatureSetPoint               Sun Jan 25 17:56:01.144 2009  to  Sun Jan 25 17:56:01.144 2009   (  0.00) secs
                    Hydraulic bearing command set temperature set point failed:temp -7.8330832e+00

  58  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sun Jan 25 19:29:59.503 2009  to  Sun Jan 25 19:29:59.503 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

  59  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 19:56:10.065 2009  to  Sun Jan 25 19:56:10.065 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 20:01:57.158 2009  to  Sun Jan 25 20:01:57.158 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  61  STARTUP   OSS        startup                                                       Sun Jan 25 20:10:28.426 2009  to  Sun Jan 25 20:10:28.426 2009   (  0.00) secs
                    The oss was started.

  62  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:11:09.201 2009  to  Sun Jan 25 20:11:09.201 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

  63  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:11:11.533 2009  to  Sun Jan 25 20:11:11.533 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] complete

  64  FAILED    OSS        side[0].tertiary_mirror.homesel.failed                        Sun Jan 25 20:13:58.410 2009  to  Sun Jan 25 20:13:58.410 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [homeSel] Umac brake not set.

  65  FAILED    OSS        side[0].tertiary_mirror.homemirror.failed                     Sun Jan 25 20:17:25.257 2009  to  Sun Jan 25 20:17:25.257 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [homeMirror.waitForInPositionAll.isInPositionAll] Open loop

  66  SHUTDOWN  OSS        shutdown                                                      Sun Jan 25 20:29:39.036 2009  to  Sun Jan 25 20:29:39.036 2009   (  0.00) secs
                    The oss was shut down.

  67  STARTUP   OSS        startup                                                       Sun Jan 25 20:43:43.624 2009  to  Sun Jan 25 20:43:43.624 2009   (  0.00) secs
                    The oss was started.

  68  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:44:23.657 2009  to  Sun Jan 25 20:44:23.657 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] started

  69  STARTUP   OSS        side[0].tertiary_mirror.startup                               Sun Jan 25 20:44:26.077 2009  to  Sun Jan 25 20:44:26.077 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [startup] complete

  70  FAILED    OSS        side[0].tertiary_mirror.init.failed                           Sun Jan 25 20:44:53.363 2009  to  Sun Jan 25 20:44:53.363 2009   (  0.00) secs
                    oss.side[0].tertiary_mirror: [init.waitForInPositionAll.isInPositionAll] Open loop

  71  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:08:39.950 2009  to  Sun Jan 25 21:08:39.950 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  72  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:09:25.733 2009  to  Sun Jan 25 21:09:25.733 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:09:44.453 2009  to  Sun Jan 25 21:09:44.453 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:10:13.583 2009  to  Sun Jan 25 21:10:13.583 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  75  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sun Jan 25 21:11:59.674 2009  to  Sun Jan 25 21:11:59.674 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  76  FAILED    MCS.MCSPU  MCSPU.AZDrive.hbsNotReady                                     Mon Jan 26 00:42:50.014 2009  to  Mon Jan 26 00:42:50.014 2009   (  0.00) secs
                    Cannot leave IDLE state, because HBS is not ready or shows alarm.

  77  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 26 01:45:23.240 2009  to  Mon Jan 26 01:45:23.240 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  78  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 26 01:45:23.293 2009  to  Mon Jan 26 01:45:23.293 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  79  FAILED    PMC        thermal.badReceive                                            Mon Jan 26 01:45:23.345 2009  to  Mon Jan 26 01:45:23.345 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  80  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 26 03:17:48.790 2009  to  Mon Jan 26 03:19:35.505 2009   (106.71) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485742905092592e+04, time 5.850000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  81  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:18:34.782 2009  to  Mon Jan 26 03:19:01.855 2009   ( 27.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  82  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:18:34.748 2009  to  Mon Jan 26 03:19:01.925 2009   ( 27.18) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  83  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 03:43:29.607 2009  to  Mon Jan 26 03:43:29.607 2009   (  0.00) secs
                    left PMC AirPressure length error: expected 100, got 96

  84  FAILED    PMC        VxInterface.close                                             Mon Jan 26 03:43:29.637 2009  to  Mon Jan 26 03:43:29.637 2009   (  0.00) secs
                    left PMC AirPressure closing network connection

  85  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:46:56.441 2009  to  Mon Jan 26 03:47:21.724 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  86  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:46:56.474 2009  to  Mon Jan 26 03:47:21.760 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  87  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 03:47:21.665 2009  to  Mon Jan 26 03:47:21.887 2009   (  0.22) secs
                    left PSF SetInstrumentOffsets failed

  88  FAILED    IIF        command.moveFocus                                             Mon Jan 26 03:47:21.635 2009  to  Mon Jan 26 03:47:21.979 2009   (  0.34) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485744954861111e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  89  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:47:21.760 2009  to  Mon Jan 26 03:47:21.784 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  90  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:47:21.724 2009  to  Mon Jan 26 03:47:21.832 2009   (  0.11) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  91  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 03:47:21.692 2009  to  Mon Jan 26 03:47:21.856 2009   (  0.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  92  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:47:26.555 2009  to  Mon Jan 26 03:47:26.555 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  93  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:47:26.589 2009  to  Mon Jan 26 03:47:26.589 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  94  FAILED    PSF        primaryMirror.command.revert                                  Mon Jan 26 03:55:32.564 2009  to  Mon Jan 26 03:56:04.853 2009   ( 32.29) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

  95  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:55:37.691 2009  to  Mon Jan 26 03:56:04.826 2009   ( 27.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  96  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:55:37.720 2009  to  Mon Jan 26 03:56:04.792 2009   ( 27.07) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 03:56:04.273 2009  to  Mon Jan 26 03:56:33.171 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  98  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 03:56:04.250 2009  to  Mon Jan 26 03:56:33.050 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror chaseStop started

  99  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:56:06.196 2009  to  Mon Jan 26 03:56:34.338 2009   ( 28.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 100  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:56:06.228 2009  to  Mon Jan 26 03:56:34.305 2009   ( 28.08) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 101  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 03:56:35.194 2009  to  Mon Jan 26 03:56:35.194 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror ChaseStop Command Complete

 102  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 03:56:35.231 2009  to  Mon Jan 26 03:56:35.231 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror chaseStop complete

 103  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 03:57:43.395 2009  to  Mon Jan 26 03:57:57.540 2009   ( 14.14) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 104  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Mon Jan 26 03:57:43.377 2009  to  Mon Jan 26 03:57:57.564 2009   ( 14.19) secs
                    left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

 105  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 03:57:43.428 2009  to  Mon Jan 26 03:57:57.503 2009   ( 14.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 106  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:40.467 2009  to  Mon Jan 26 04:33:48.348 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 107  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:40.437 2009  to  Mon Jan 26 04:33:48.298 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 108  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 04:33:48.234 2009  to  Mon Jan 26 04:33:48.522 2009   (  0.29) secs
                    left PSF SetInstrumentOffsets failed

 109  FAILED    IIF        command.moveFocus                                             Mon Jan 26 04:33:48.196 2009  to  Mon Jan 26 04:33:48.687 2009   (  0.49) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485748180555556e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 110  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:48.298 2009  to  Mon Jan 26 04:33:48.440 2009   (  0.14) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 111  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 04:33:48.264 2009  to  Mon Jan 26 04:33:48.485 2009   (  0.22) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 112  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:48.348 2009  to  Mon Jan 26 04:33:48.373 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 113  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:33:51.507 2009  to  Mon Jan 26 04:33:51.507 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 114  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:33:51.555 2009  to  Mon Jan 26 04:33:51.555 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 115  FAILED    PMC        VxInterface.close                                             Mon Jan 26 04:36:27.563 2009  to  Mon Jan 26 04:36:27.563 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 116  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 04:36:27.544 2009  to  Mon Jan 26 04:36:27.544 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 117  FAILED    PSF        primaryMirror.command.revert                                  Mon Jan 26 04:44:39.318 2009  to  Mon Jan 26 04:45:02.645 2009   ( 23.33) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

 118  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:44:41.520 2009  to  Mon Jan 26 04:45:02.584 2009   ( 21.06) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 119  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:44:41.465 2009  to  Mon Jan 26 04:45:02.622 2009   ( 21.16) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 120  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 04:45:01.895 2009  to  Mon Jan 26 04:45:14.805 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 121  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 04:45:01.845 2009  to  Mon Jan 26 04:45:14.780 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror chaseStop started

 122  FAILED    PSF        primaryMirror.command.setGlobalOffsets                        Mon Jan 26 04:45:03.640 2009  to  Mon Jan 26 04:45:15.783 2009   ( 12.14) secs
                    left PSF primary mirror setGlobalOffsets failed because Primary mirror collimation failed

 123  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 04:45:03.688 2009  to  Mon Jan 26 04:45:15.730 2009   ( 12.04) secs
                    Started event but no Complete event
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 124  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 04:45:03.659 2009  to  Mon Jan 26 04:45:15.762 2009   ( 12.10) secs
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 125  SEQERROR  PMC        mirror.command.chase.stop                                     Mon Jan 26 04:45:16.827 2009  to  Mon Jan 26 04:45:16.827 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror ChaseStop Command Complete

 126  SEQERROR  PSF        primaryMirror.command.chaseStop                               Mon Jan 26 04:45:16.864 2009  to  Mon Jan 26 04:45:16.864 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror chaseStop complete

 127  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 04:47:08.035 2009  to  Mon Jan 26 04:47:08.035 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 128  FAILED    PMC        VxInterface.close                                             Mon Jan 26 04:47:08.087 2009  to  Mon Jan 26 04:47:08.087 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 129  SEQERROR  IIF        command.authorize                                             Mon Jan 26 05:03:32.164 2009  to  Mon Jan 26 05:03:27.166 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Authorize command started for both LBC at prime focus (IIF both side)

 130  SEQERROR  IIF        command.authorize                                             Mon Jan 26 05:03:40.455 2009  to  Mon Jan 26 05:03:40.455 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Authorize command complete for both LBC at prime focus (IIF both side)

 131  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:17:20.794 2009  to  Mon Jan 26 05:17:25.536 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 132  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:17:20.826 2009  to  Mon Jan 26 05:17:25.558 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 133  FAILED    PMC        VxInterface.close                                             Mon Jan 26 05:17:24.384 2009  to  Mon Jan 26 05:17:24.384 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 134  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 05:17:24.365 2009  to  Mon Jan 26 05:17:24.365 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 135  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:17:30.598 2009  to  Mon Jan 26 05:17:30.598 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 136  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:17:30.642 2009  to  Mon Jan 26 05:17:30.642 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 137  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 26 05:29:28.901 2009  to  Mon Jan 26 05:33:00.867 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 138  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 26 05:29:29.175 2009  to  Mon Jan 26 05:29:29.175 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 139  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:25.968 2009  to  Mon Jan 26 05:37:29.470 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 140  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:25.940 2009  to  Mon Jan 26 05:37:29.443 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 141  FAILED    IIF        command.moveFocus                                             Mon Jan 26 05:37:29.311 2009  to  Mon Jan 26 05:37:29.687 2009   (  0.38) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485752603009259e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 142  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 05:37:29.405 2009  to  Mon Jan 26 05:37:29.601 2009   (  0.20) secs
                    left PSF SetInstrumentOffsets failed

 143  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:29.443 2009  to  Mon Jan 26 05:37:29.545 2009   (  0.10) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 144  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 05:37:29.428 2009  to  Mon Jan 26 05:37:29.582 2009   (  0.15) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 145  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:29.470 2009  to  Mon Jan 26 05:37:29.498 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 146  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:37:40.011 2009  to  Mon Jan 26 05:37:40.011 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 147  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:37:40.042 2009  to  Mon Jan 26 05:37:40.042 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 148  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:55:47.244 2009  to  Mon Jan 26 05:55:51.985 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 149  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:55:47.267 2009  to  Mon Jan 26 05:55:52.013 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 150  FAILED    IIF        command.moveFocus                                             Mon Jan 26 05:55:51.902 2009  to  Mon Jan 26 05:55:52.204 2009   (  0.30) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485753878472222e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 151  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:55:52.013 2009  to  Mon Jan 26 05:55:52.033 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 152  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 26 05:55:51.932 2009  to  Mon Jan 26 05:55:52.118 2009   (  0.19) secs
                    left PSF SetInstrumentOffsets failed

 153  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:55:51.985 2009  to  Mon Jan 26 05:55:52.066 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 154  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 26 05:55:51.958 2009  to  Mon Jan 26 05:55:52.092 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 155  FAILED    PMC        VxInterface.close                                             Mon Jan 26 05:56:28.534 2009  to  Mon Jan 26 05:56:28.534 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 156  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 05:56:28.514 2009  to  Mon Jan 26 05:56:28.514 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 157  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 26 05:56:30.367 2009  to  Mon Jan 26 05:56:30.367 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 158  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 26 05:56:30.477 2009  to  Mon Jan 26 05:56:30.477 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 159  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 06:16:57.931 2009  to  Mon Jan 26 06:16:57.931 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 160  FAILED    PMC        VxInterface.close                                             Mon Jan 26 06:16:57.983 2009  to  Mon Jan 26 06:16:57.983 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 161  FAILED    PMC        VxInterface.close                                             Mon Jan 26 06:19:48.924 2009  to  Mon Jan 26 06:19:48.924 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 162  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 26 06:19:48.904 2009  to  Mon Jan 26 06:19:48.904 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 163  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 26 06:23:04.450 2009  to  Mon Jan 26 06:23:04.450 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 164  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 26 06:23:04.432 2009  to  Mon Jan 26 06:23:04.432 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 165  FAILED    PMC        thermal.badReceive                                            Mon Jan 26 06:23:04.468 2009  to  Mon Jan 26 06:23:04.468 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 166  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:24:56.753 2009  to  Mon Jan 26 06:24:56.753 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 167  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:24:56.788 2009  to  Mon Jan 26 06:24:56.788 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 168  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:06.854 2009  to  Mon Jan 26 06:25:06.854 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 169  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:06.888 2009  to  Mon Jan 26 06:25:06.888 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 170  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:16.966 2009  to  Mon Jan 26 06:25:16.966 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 171  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:17.019 2009  to  Mon Jan 26 06:25:17.019 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 172  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:28.113 2009  to  Mon Jan 26 06:25:28.113 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

 173  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:28.197 2009  to  Mon Jan 26 06:25:28.197 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 174  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:28.166 2009  to  Mon Jan 26 06:25:28.166 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 175  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:39.280 2009  to  Mon Jan 26 06:25:39.280 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 176  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:39.269 2009  to  Mon Jan 26 06:25:39.269 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

 177  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:39.292 2009  to  Mon Jan 26 06:25:39.292 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 178  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:25:50.341 2009  to  Mon Jan 26 06:25:50.341 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

 179  FAILED    ECS        hydraulicBearing.badPMCData                                   Mon Jan 26 06:25:50.365 2009  to  Mon Jan 26 06:25:50.365 2009   (  0.00) secs
                    ECS hydraulic bearing setpoint: no current PMC thermal data

 180  FAILED    ECS        instrumentCooling.badPMCData                                  Mon Jan 26 06:25:50.353 2009  to  Mon Jan 26 06:25:50.353 2009   (  0.00) secs
                    ECS instrument cooling setpoint: no current PMC thermal data

 181  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:01.419 2009  to  Mon Jan 26 06:26:01.419 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

 182  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:14.652 2009  to  Mon Jan 26 06:26:14.652 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

 183  FAILED    ECS        instrumentCooling.badSend                                     Mon Jan 26 06:26:27.558 2009  to  Mon Jan 26 06:26:27.558 2009   (  0.00) secs
                    ECS instrument cooling setpoint: bad send to thermal computer, error is 5005

**********************************************************
    Reporting period ending:   Mon Jan 26 07:47:59.955 2009
********************************************************************************************************