********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jan 23 2009 to Jan 24 2009
 
    Reporting period beginning:   Fri Jan 23 17:13:00.022 2009
    Reporting period ending:      Sat Jan 24 07:48:59.881 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.04    0.04    0.01    0.07   100.0 %          2          2                      
                                                                       0.04    0.04    0.01    0.07
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    9.21    4.16    2.24   77.87    98.5 %         68         67          1           
                                                                       9.27    4.13    2.24   77.87
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.42    2.98    2.24    6.38   100.0 %         66         66                      
                                                                       1.42    2.98    2.24    6.38

IIF Single Event Activity                                          
      Nothing to report

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Fri Jan 23 21:44:57.870 2009  to  Fri Jan 23 21:45:04.205 2009   (  6.33) secs
                    IIF MoveFocus command started for right LBC for 8.100000000000000e-02
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4491                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  8982                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    16                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     5                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      23                      
     plc.read.failed. . . . . . . . . . . . . . . . . . . . . . . .                  1           
     plc.writeHS.failed . . . . . . . . . . . . . . . . . . . . . .                  2           

ECS Events of Interest

   1  FAILED    ECS        plc.read.failed                                               Fri Jan 23 21:18:19.411 2009  to  Fri Jan 23 21:18:19.411 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :SD1001_POSITION

   2  FAILED    ECS        plc.writeHS.failed                                            Fri Jan 23 21:18:19.412 2009  to  Fri Jan 23 21:18:19.412 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 4.5831348e+01, because PLC Read Failed

   3  FAILED    ECS        plc.writeHS.failed                                            Fri Jan 23 21:18:19.412 2009  to  Fri Jan 23 21:18:19.412 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.5831348e+01, because PLC Read Failed
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      11                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       3                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               4864           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                            19
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .      14                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .      19                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       8                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                            34
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            14
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            11
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      15                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      59                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            52
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      12                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      20                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.ELDrive.stowpinCommandRejected . . . . . . . . . . . . .                  4           
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 32           
     MCSPU.ELDrive.Stowpins.stowpinMoving . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      40                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.hvps . . . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.ELDrive.mcrProblem . . . . . . . . . . . . . . . . . . .                  2           
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             2
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      45                      
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 12           
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      12                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  3           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             3
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             4
 *** MCSPU.ERPlcDevice.readError. . . . . . . . . . . . . . . . . .               7186           
     MCSPU.HydrostaticBearing.HBS_on_fail . . . . . . . . . . . . .                  6           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:00.884 2009  to  Fri Jan 23 17:13:00.884 2009   (  0.00) secs
                    EL bad poly no. 830959: BAD: poly EL = -5.468046e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:03.935 2009  to  Fri Jan 23 17:13:03.935 2009   (  0.00) secs
                    EL bad poly no. 831005: BAD: poly EL = -5.467675e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:06.960 2009  to  Fri Jan 23 17:13:06.960 2009   (  0.00) secs
                    EL bad poly no. 831052: BAD: poly EL = -5.467306e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:09.976 2009  to  Fri Jan 23 17:13:09.976 2009   (  0.00) secs
                    EL bad poly no. 831099: BAD: poly EL = -5.466939e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:12.993 2009  to  Fri Jan 23 17:13:12.993 2009   (  0.00) secs
                    EL bad poly no. 831145: BAD: poly EL = -5.466571e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:15.994 2009  to  Fri Jan 23 17:13:15.994 2009   (  0.00) secs
                    EL bad poly no. 831191: BAD: poly EL = -5.466205e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:19.042 2009  to  Fri Jan 23 17:13:19.042 2009   (  0.00) secs
                    EL bad poly no. 831238: BAD: poly EL = -5.465832e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:22.071 2009  to  Fri Jan 23 17:13:22.071 2009   (  0.00) secs
                    EL bad poly no. 831285: BAD: poly EL = -5.465461e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:25.119 2009  to  Fri Jan 23 17:13:25.119 2009   (  0.00) secs
                    EL bad poly no. 831333: BAD: poly EL = -5.465088e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:28.130 2009  to  Fri Jan 23 17:13:28.130 2009   (  0.00) secs
                    EL bad poly no. 831380: BAD: poly EL = -5.464718e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:31.141 2009  to  Fri Jan 23 17:13:31.141 2009   (  0.00) secs
                    EL bad poly no. 831425: BAD: poly EL = -5.464349e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:34.146 2009  to  Fri Jan 23 17:13:34.146 2009   (  0.00) secs
                    EL bad poly no. 831471: BAD: poly EL = -5.463979e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:37.217 2009  to  Fri Jan 23 17:13:37.217 2009   (  0.00) secs
                    EL bad poly no. 831518: BAD: poly EL = -5.463601e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:40.246 2009  to  Fri Jan 23 17:13:40.246 2009   (  0.00) secs
                    EL bad poly no. 831565: BAD: poly EL = -5.463228e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:43.265 2009  to  Fri Jan 23 17:13:43.265 2009   (  0.00) secs
                    EL bad poly no. 831612: BAD: poly EL = -5.462855e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:46.310 2009  to  Fri Jan 23 17:13:46.310 2009   (  0.00) secs
                    EL bad poly no. 831659: BAD: poly EL = -5.462479e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:49.319 2009  to  Fri Jan 23 17:13:49.319 2009   (  0.00) secs
                    EL bad poly no. 831706: BAD: poly EL = -5.462107e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:52.349 2009  to  Fri Jan 23 17:13:52.349 2009   (  0.00) secs
                    EL bad poly no. 831753: BAD: poly EL = -5.461732e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:55.414 2009  to  Fri Jan 23 17:13:55.414 2009   (  0.00) secs
                    EL bad poly no. 831800: BAD: poly EL = -5.461352e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:58.411 2009  to  Fri Jan 23 17:13:58.411 2009   (  0.00) secs
                    EL bad poly no. 831846: BAD: poly EL = -5.460980e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:01.441 2009  to  Fri Jan 23 17:14:01.441 2009   (  0.00) secs
                    EL bad poly no. 831892: BAD: poly EL = -5.460604e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:04.477 2009  to  Fri Jan 23 17:14:04.477 2009   (  0.00) secs
                    EL bad poly no. 831939: BAD: poly EL = -5.460227e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:07.517 2009  to  Fri Jan 23 17:14:07.517 2009   (  0.00) secs
                    EL bad poly no. 831985: BAD: poly EL = -5.459848e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:10.546 2009  to  Fri Jan 23 17:14:10.546 2009   (  0.00) secs
                    EL bad poly no. 832033: BAD: poly EL = -5.459471e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:13.605 2009  to  Fri Jan 23 17:14:13.605 2009   (  0.00) secs
                    EL bad poly no. 832081: BAD: poly EL = -5.459089e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:35:25.346 2009  to  Fri Jan 23 17:35:25.346 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  27  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:35:26.020 2009  to  Fri Jan 23 17:35:26.020 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  28  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:38:20.109 2009  to  Fri Jan 23 17:38:20.109 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  29  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:38:21.531 2009  to  Fri Jan 23 17:38:21.531 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.514 2009  to  Fri Jan 23 17:47:44.514 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.515 2009  to  Fri Jan 23 17:47:44.515 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.516 2009  to  Fri Jan 23 17:47:44.516 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.517 2009  to  Fri Jan 23 17:47:44.517 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.544 2009  to  Fri Jan 23 17:47:44.544 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  35  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.545 2009  to  Fri Jan 23 17:47:44.545 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.546 2009  to  Fri Jan 23 17:47:44.546 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  37  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.546 2009  to  Fri Jan 23 17:47:44.546 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  38  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jan 23 17:47:44.767 2009  to  Fri Jan 23 17:47:44.767 2009   (  0.00) secs
                    LFT StowIdleIn: stowpin is moving but hasn't been commanded to move.

  39  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jan 23 17:47:45.153 2009  to  Fri Jan 23 17:47:45.153 2009   (  0.00) secs
                    RT StowIdleIn: stowpin is moving but hasn't been commanded to move.

  40  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jan 23 17:55:01.975 2009  to  Fri Jan 23 17:55:01.975 2009   (  0.00) secs
                    Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  41  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jan 23 17:55:02.112 2009  to  Fri Jan 23 17:55:02.112 2009   (  0.00) secs
                    Master Ctrl Relay has opened because EL MCR is off: EL locked out!

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 18:50:26.217 2009  to  Fri Jan 23 18:50:26.217 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 18:50:26.222 2009  to  Fri Jan 23 18:50:26.222 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 18:50:26.313 2009  to  Fri Jan 23 18:50:26.313 2009   (  0.00) secs
                    drive cabinet has turned on.

  45  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.838 2009  to  Fri Jan 23 18:50:26.838 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  46  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.838 2009  to  Fri Jan 23 18:50:26.838 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  47  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.839 2009  to  Fri Jan 23 18:50:26.839 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  48  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.840 2009  to  Fri Jan 23 18:50:26.840 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  49  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.842 2009  to  Fri Jan 23 18:50:26.842 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  50  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.842 2009  to  Fri Jan 23 18:50:26.842 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  51  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.843 2009  to  Fri Jan 23 18:50:26.843 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  52  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.844 2009  to  Fri Jan 23 18:50:26.844 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  53  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:50.935 2009  to  Fri Jan 23 19:26:50.935 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 1 times

  54  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:51.970 2009  to  Fri Jan 23 19:26:51.970 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 2 times

  55  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:53.004 2009  to  Fri Jan 23 19:26:53.004 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 3 times

  56  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:54.046 2009  to  Fri Jan 23 19:26:54.046 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 4 times

  57  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:55.088 2009  to  Fri Jan 23 19:26:55.088 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 5 times

  58  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:56.132 2009  to  Fri Jan 23 19:26:56.132 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 6 times

  59  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:57.174 2009  to  Fri Jan 23 19:26:57.174 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 7 times

  60  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:58.217 2009  to  Fri Jan 23 19:26:58.217 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 8 times

  61  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:59.258 2009  to  Fri Jan 23 19:26:59.258 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 9 times

  62  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:00.306 2009  to  Fri Jan 23 19:27:00.306 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 10 times

  63  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:01.345 2009  to  Fri Jan 23 19:27:01.345 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 11 times

  64  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:02.393 2009  to  Fri Jan 23 19:27:02.393 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 12 times

  65  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:03.456 2009  to  Fri Jan 23 19:27:03.456 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 13 times

  66  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:04.498 2009  to  Fri Jan 23 19:27:04.498 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 14 times

  67  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:05.555 2009  to  Fri Jan 23 19:27:05.555 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 15 times

  68  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:06.589 2009  to  Fri Jan 23 19:27:06.589 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 16 times

  69  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:07.620 2009  to  Fri Jan 23 19:27:07.620 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 17 times

  70  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:08.657 2009  to  Fri Jan 23 19:27:08.657 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 18 times

  71  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:09.697 2009  to  Fri Jan 23 19:27:09.697 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 19 times

  72  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:10.729 2009  to  Fri Jan 23 19:27:10.729 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 20 times

  73  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:11.775 2009  to  Fri Jan 23 19:27:11.775 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 21 times

  74  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:12.810 2009  to  Fri Jan 23 19:27:12.810 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 22 times

  75  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:13.846 2009  to  Fri Jan 23 19:27:13.846 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 23 times

  76  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:14.890 2009  to  Fri Jan 23 19:27:14.890 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 24 times

  77  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:15.929 2009  to  Fri Jan 23 19:27:15.929 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 25 times

  78  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 19:32:57.764 2009  to  Fri Jan 23 19:32:57.764 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  79  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 19:32:57.771 2009  to  Fri Jan 23 19:32:57.771 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  80  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 19:32:57.858 2009  to  Fri Jan 23 19:32:57.858 2009   (  0.00) secs
                    drive cabinet has turned on.

  81  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.370 2009  to  Fri Jan 23 19:32:58.370 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  82  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.370 2009  to  Fri Jan 23 19:32:58.370 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  83  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.371 2009  to  Fri Jan 23 19:32:58.371 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  84  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.372 2009  to  Fri Jan 23 19:32:58.372 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  85  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.373 2009  to  Fri Jan 23 19:32:58.373 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  86  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.374 2009  to  Fri Jan 23 19:32:58.374 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  87  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.375 2009  to  Fri Jan 23 19:32:58.375 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  88  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.376 2009  to  Fri Jan 23 19:32:58.376 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  89  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:34.141 2009  to  Fri Jan 23 21:27:34.141 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  90  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:50.729 2009  to  Fri Jan 23 21:27:50.729 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  91  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:50.756 2009  to  Fri Jan 23 21:27:50.756 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  92  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:52.809 2009  to  Fri Jan 23 21:27:52.809 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  93  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:28:01.392 2009  to  Fri Jan 23 21:28:01.392 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  94  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 21:29:12.140 2009  to  Fri Jan 23 21:29:12.140 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  95  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 21:29:39.797 2009  to  Fri Jan 23 21:29:39.797 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  96  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:30:01.784 2009  to  Fri Jan 23 21:30:01.784 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  97  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:07:35.264 2009  to  Fri Jan 23 22:07:35.264 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  98  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:07:52.549 2009  to  Fri Jan 23 22:07:52.549 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

  99  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:08:23.885 2009  to  Fri Jan 23 22:08:23.885 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 100  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:12:11.613 2009  to  Fri Jan 23 22:12:11.613 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 101  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 22:13:06.098 2009  to  Fri Jan 23 22:13:06.098 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 22:13:06.103 2009  to  Fri Jan 23 22:13:06.103 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 103  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 22:13:06.191 2009  to  Fri Jan 23 22:13:06.191 2009   (  0.00) secs
                    drive cabinet has turned on.

 104  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 22:13:06.714 2009  to  Fri Jan 23 22:13:06.714 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                         
      Nothing to report

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest
      Nothing to report
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.01    1.04    1.02    1.06   100.0 %          6          6                      
                                                                       0.01    1.04    1.02    1.06
     command.recoverPanic . . . . . . . . . . . . . . . . . . . . .    0.02    5.04    5.03    5.06   100.0 %          2          2                      
                                                                       0.02    5.04    5.03    5.06
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.03   66.16   66.14   66.19   100.0 %          2          2                      
                                                                       0.03   66.16   66.14   66.19
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    6.60    3.30    2.02   77.21    99.3 %        134        133          1           
                                                                       6.62    3.28    2.02   77.21
     mirror.command.panic . . . . . . . . . . . . . . . . . . . . .    0.00   11.07   11.07   11.07   100.0 %          2          2                      
                                                                       0.00   11.07   11.07   11.07
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .  110.41   81.78    2.17  226.62    40.0 %          5          2          3           
                                                                      36.09  201.10  175.58  226.62
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.03    0.12    0.06    0.15   100.0 %          5          5                      
                                                                       0.03    0.12    0.06    0.15

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                         16297
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                         10741
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             2
     mirror.panic . . . . . . . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.bleed. . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     airLoop.startChecks. . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.off. . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.off. . . . . . . . . . . . . . . . . .      10                      
     airLoop.on . . . . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.power.on . . . . . . . . . . . . . . . . . . . . . . .      10                      
     airLoop.integratorCheck.on . . . . . . . . . . . . . . . . . .      10                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                             6
     actuator.getForce.readError. . . . . . . . . . . . . . . . . .                  1           
     actuator.setForce.readError. . . . . . . . . . . . . . . . . .                  1           
     actuator.setForce.addressError . . . . . . . . . . . . . . . .                  2           
 *** actuator.reset . . . . . . . . . . . . . . . . . . . . . . . .                 54           
     voltageMonitor.time.exceeded . . . . . . . . . . . . . . . . .                             1
     outerLoop.time.exceeded. . . . . . . . . . . . . . . . . . . .                             1
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     actuator.forceMonitor2.panic . . . . . . . . . . . . . . . . .                  2           
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       6                      
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             9
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             3
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  5           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  5           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  5           
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  1           

PMC Events of Interest

   1  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:13:09.167 2009  to  Fri Jan 23 17:13:11.399 2009   (  2.23) secs
                    right PMC Mirror AutoRaise Command Failed because Raise never started

   2  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:14:41.519 2009  to  Fri Jan 23 17:14:43.692 2009   (  2.17) secs
                    right PMC Mirror AutoRaise Command Failed because Raise never started

   3  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:14:53.933 2009  to  Fri Jan 23 17:14:56.201 2009   (  2.27) secs
                    left PMC Mirror AutoRaise Command Failed because Raise never started

   4  FAILED    PMC        mirror.panic                                                  Fri Jan 23 17:19:37.564 2009  to  Fri Jan 23 17:19:37.564 2009   (  0.00) secs
                    left PMC ** PANIC: User Button

   5  FAILED    PMC        mirror.panic                                                  Fri Jan 23 17:23:46.574 2009  to  Fri Jan 23 17:23:46.574 2009   (  0.00) secs
                    right PMC ** PANIC: User Button

   6  FAILED    PMC        actuator.getForce.readError                                   Fri Jan 23 17:23:46.881 2009  to  Fri Jan 23 17:23:46.881 2009   (  0.00) secs
                    right PMC Actuator 139 get force read error: -3

   7  FAILED    PMC        actuator.setForce.readError                                   Fri Jan 23 17:23:46.913 2009  to  Fri Jan 23 17:23:46.913 2009   (  0.00) secs
                    right PMC Actuator 107 set force read error: -3

   8  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:46.979 2009  to  Fri Jan 23 17:23:46.979 2009   (  0.00) secs
                    right PMC Actuator 123 has been reset

   9  FAILED    PMC        actuator.setForce.addressError                                Fri Jan 23 17:23:46.946 2009  to  Fri Jan 23 17:23:46.946 2009   (  0.00) secs
                    right PMC Actuator 112 set force bad return: 255 instead of 2

  10  FAILED    PMC        actuator.setForce.addressError                                Fri Jan 23 17:23:47.022 2009  to  Fri Jan 23 17:23:47.022 2009   (  0.00) secs
                    right PMC Actuator 130 set force bad return: 130 instead of 4

  11  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.065 2009  to  Fri Jan 23 17:23:47.065 2009   (  0.00) secs
                    right PMC Actuator 135 has been reset

  12  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.090 2009  to  Fri Jan 23 17:23:47.090 2009   (  0.00) secs
                    right PMC Actuator 134 has been reset

  13  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.139 2009  to  Fri Jan 23 17:23:47.139 2009   (  0.00) secs
                    right PMC Actuator 132 has been reset

  14  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.191 2009  to  Fri Jan 23 17:23:47.191 2009   (  0.00) secs
                    right PMC Actuator 133 has been reset

  15  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.219 2009  to  Fri Jan 23 17:23:47.219 2009   (  0.00) secs
                    right PMC Actuator 139 has been reset

  16  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.245 2009  to  Fri Jan 23 17:23:47.245 2009   (  0.00) secs
                    right PMC Actuator 136 has been reset

  17  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.271 2009  to  Fri Jan 23 17:23:47.271 2009   (  0.00) secs
                    right PMC Actuator 141 has been reset

  18  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.295 2009  to  Fri Jan 23 17:23:47.295 2009   (  0.00) secs
                    right PMC Actuator 124 has been reset

  19  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.322 2009  to  Fri Jan 23 17:23:47.322 2009   (  0.00) secs
                    right PMC Actuator 125 has been reset

  20  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.368 2009  to  Fri Jan 23 17:23:47.368 2009   (  0.00) secs
                    right PMC Actuator 131 has been reset

  21  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.392 2009  to  Fri Jan 23 17:23:47.392 2009   (  0.00) secs
                    right PMC Actuator 211 has been reset

  22  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.416 2009  to  Fri Jan 23 17:23:47.416 2009   (  0.00) secs
                    right PMC Actuator 207 has been reset

  23  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.443 2009  to  Fri Jan 23 17:23:47.443 2009   (  0.00) secs
                    right PMC Actuator 140 has been reset

  24  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.470 2009  to  Fri Jan 23 17:23:47.470 2009   (  0.00) secs
                    right PMC Actuator 215 has been reset

  25  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.496 2009  to  Fri Jan 23 17:23:47.496 2009   (  0.00) secs
                    right PMC Actuator 210 has been reset

  26  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.521 2009  to  Fri Jan 23 17:23:47.521 2009   (  0.00) secs
                    right PMC Actuator 126 has been reset

  27  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.546 2009  to  Fri Jan 23 17:23:47.546 2009   (  0.00) secs
                    right PMC Actuator 129 has been reset

  28  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.597 2009  to  Fri Jan 23 17:23:47.597 2009   (  0.00) secs
                    right PMC Actuator 138 has been reset

  29  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.620 2009  to  Fri Jan 23 17:23:47.620 2009   (  0.00) secs
                    right PMC Actuator 213 has been reset

  30  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.645 2009  to  Fri Jan 23 17:23:47.645 2009   (  0.00) secs
                    right PMC Actuator 218 has been reset

  31  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.669 2009  to  Fri Jan 23 17:23:47.669 2009   (  0.00) secs
                    right PMC Actuator 209 has been reset

  32  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.695 2009  to  Fri Jan 23 17:23:47.695 2009   (  0.00) secs
                    right PMC Actuator 231 has been reset

  33  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.721 2009  to  Fri Jan 23 17:23:47.721 2009   (  0.00) secs
                    right PMC Actuator 228 has been reset

  34  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.748 2009  to  Fri Jan 23 17:23:47.748 2009   (  0.00) secs
                    right PMC Actuator 142 has been reset

  35  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Jan 23 17:53:24.755 2009  to  Fri Jan 23 17:53:24.755 2009   (  0.00) secs
                    left PMC Actuator 328 force monitor 2 PANIC! 275.6 lbs, limit is 143.8

  36  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 19:55:26.031 2009  to  Fri Jan 23 19:55:26.031 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  37  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 19:55:26.016 2009  to  Fri Jan 23 19:55:26.016 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  38  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 19:55:25.984 2009  to  Fri Jan 23 19:55:25.984 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  39  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 21:04:10.973 2009  to  Fri Jan 23 21:04:10.973 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  40  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 21:04:10.957 2009  to  Fri Jan 23 21:04:10.957 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  41  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 21:04:10.937 2009  to  Fri Jan 23 21:04:10.937 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  42  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan 23 21:44:57.970 2009  to  Fri Jan 23 21:45:04.016 2009   (  6.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  43  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 23:07:34.324 2009  to  Fri Jan 23 23:07:34.324 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  44  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 23:07:34.354 2009  to  Fri Jan 23 23:07:34.354 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  45  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 23:07:34.339 2009  to  Fri Jan 23 23:07:34.339 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  46  FAILED    PMC        actuator.forceMonitor1.panic                                  Fri Jan 23 23:21:11.639 2009  to  Fri Jan 23 23:21:11.639 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 1 PANIC! -322.6 lbs, limit is 0.0

  47  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Jan 23 23:21:11.690 2009  to  Fri Jan 23 23:21:11.690 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 2 PANIC! 514.7 lbs, limit is 0.0

  48  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan 24 05:25:51.519 2009  to  Sat Jan 24 05:25:51.519 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  49  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan 24 05:25:51.504 2009  to  Sat Jan 24 05:25:51.504 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  50  FAILED    PMC        thermal.badReceive                                            Sat Jan 24 05:25:51.531 2009  to  Sat Jan 24 05:25:51.531 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  51  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan 24 06:49:01.118 2009  to  Sat Jan 24 06:49:01.118 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  52  FAILED    PMC        thermal.badReceive                                            Sat Jan 24 06:49:01.156 2009  to  Sat Jan 24 06:49:01.156 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  53  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan 24 06:49:01.139 2009  to  Sat Jan 24 06:49:01.139 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    6.61    3.47    2.15   77.52    99.3 %        134        133          1           
                                                                       6.64    3.45    2.15   77.52
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    6.61    3.38    2.07   77.33    99.3 %        134        133          1           
                                                                       6.63    3.36    2.07   77.33
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    6.61    3.42    2.11   77.41    99.3 %        134        133          1           
                                                                       6.63    3.40    2.11   77.41

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .              238522           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.063 2009  to  Fri Jan 23 17:13:00.063 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   2  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.318 2009  to  Fri Jan 23 17:13:00.318 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   3  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.570 2009  to  Fri Jan 23 17:13:00.570 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   4  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.825 2009  to  Fri Jan 23 17:13:00.825 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   5  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.072 2009  to  Fri Jan 23 17:13:01.072 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7180690e-01 7.1340203e-01 -6.0282297e+00 -1.2072754e+00 2.8346361e+01 6.0986977e+00

   6  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.319 2009  to  Fri Jan 23 17:13:01.319 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7180690e-01 7.1340203e-01 -6.0282297e+00 -1.2072754e+00 2.8346361e+01 6.0986977e+00

   7  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.563 2009  to  Fri Jan 23 17:13:01.563 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

   8  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.818 2009  to  Fri Jan 23 17:13:01.818 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

   9  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.073 2009  to  Fri Jan 23 17:13:02.073 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146763e-01 7.1403360e-01 -6.0280585e+00 -1.2387695e+00 2.8298939e+01 6.0874977e+00

  10  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.318 2009  to  Fri Jan 23 17:13:02.318 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  11  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.571 2009  to  Fri Jan 23 17:13:02.571 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  12  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.826 2009  to  Fri Jan 23 17:13:02.826 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  13  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.069 2009  to  Fri Jan 23 17:13:03.069 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7149433e-01 7.1399641e-01 -6.0274754e+00 -1.2851372e+00 2.8300728e+01 6.0996246e+00

  14  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.321 2009  to  Fri Jan 23 17:13:03.321 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  15  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.562 2009  to  Fri Jan 23 17:13:03.562 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  16  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.816 2009  to  Fri Jan 23 17:13:03.816 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  17  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.065 2009  to  Fri Jan 23 17:13:04.065 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

  18  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.306 2009  to  Fri Jan 23 17:13:04.306 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7128589e-01 7.1369600e-01 -6.0276809e+00 -1.2008553e+00 2.8357492e+01 6.0884018e+00

  19  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.551 2009  to  Fri Jan 23 17:13:04.551 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7128589e-01 7.1369600e-01 -6.0276809e+00 -1.2008553e+00 2.8357492e+01 6.0884018e+00

  20  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.806 2009  to  Fri Jan 23 17:13:04.806 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  21  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.059 2009  to  Fri Jan 23 17:13:05.059 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  22  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.313 2009  to  Fri Jan 23 17:13:05.313 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  23  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.567 2009  to  Fri Jan 23 17:13:05.567 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7163017e-01 7.1434319e-01 -6.0278788e+00 -1.1874428e+00 2.8320595e+01 6.0981064e+00

  24  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.808 2009  to  Fri Jan 23 17:13:05.808 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146572e-01 7.1401799e-01 -6.0280576e+00 -1.2835388e+00 2.8298912e+01 6.0666466e+00

  25  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:06.052 2009  to  Fri Jan 23 17:13:06.052 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146572e-01 7.1401799e-01 -6.0280576e+00 -1.2835388e+00 2.8298912e+01 6.0666466e+00

  26  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan 23 21:44:57.906 2009  to  Fri Jan 23 21:45:04.129 2009   (  6.22) secs
                    right PSF SetInstrumentOffsets failed

  27  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan 23 21:44:57.941 2009  to  Fri Jan 23 21:45:04.063 2009   (  6.12) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  28  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan 23 21:44:57.924 2009  to  Fri Jan 23 21:45:04.091 2009   (  6.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.063 2009  to  Fri Jan 23 17:13:00.063 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   2  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.318 2009  to  Fri Jan 23 17:13:00.318 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   3  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.570 2009  to  Fri Jan 23 17:13:00.570 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   4  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:00.825 2009  to  Fri Jan 23 17:13:00.825 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7112752e-01 7.1404147e-01 -6.0278749e+00 -1.2164307e+00 2.8293703e+01 6.0978966e+00

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:00.884 2009  to  Fri Jan 23 17:13:00.884 2009   (  0.00) secs
                    EL bad poly no. 830959: BAD: poly EL = -5.468046e-01 rad. Too low.

   6  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.072 2009  to  Fri Jan 23 17:13:01.072 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7180690e-01 7.1340203e-01 -6.0282297e+00 -1.2072754e+00 2.8346361e+01 6.0986977e+00

   7  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.319 2009  to  Fri Jan 23 17:13:01.319 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7180690e-01 7.1340203e-01 -6.0282297e+00 -1.2072754e+00 2.8346361e+01 6.0986977e+00

   8  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.563 2009  to  Fri Jan 23 17:13:01.563 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

   9  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:01.818 2009  to  Fri Jan 23 17:13:01.818 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

  10  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.073 2009  to  Fri Jan 23 17:13:02.073 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146763e-01 7.1403360e-01 -6.0280585e+00 -1.2387695e+00 2.8298939e+01 6.0874977e+00

  11  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.318 2009  to  Fri Jan 23 17:13:02.318 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  12  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.571 2009  to  Fri Jan 23 17:13:02.571 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  13  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:02.826 2009  to  Fri Jan 23 17:13:02.826 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7165228e-01 7.1371472e-01 -6.0278540e+00 -1.2014122e+00 2.8323578e+01 6.1200066e+00

  14  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.069 2009  to  Fri Jan 23 17:13:03.069 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7149433e-01 7.1399641e-01 -6.0274754e+00 -1.2851372e+00 2.8300728e+01 6.0996246e+00

  15  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.321 2009  to  Fri Jan 23 17:13:03.321 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  16  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.562 2009  to  Fri Jan 23 17:13:03.562 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  17  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:03.816 2009  to  Fri Jan 23 17:13:03.816 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7201432e-01 7.1371150e-01 -6.0274749e+00 -1.2468758e+00 2.8289143e+01 6.0996017e+00

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:03.935 2009  to  Fri Jan 23 17:13:03.935 2009   (  0.00) secs
                    EL bad poly no. 831005: BAD: poly EL = -5.467675e-01 rad. Too low.

  19  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.065 2009  to  Fri Jan 23 17:13:04.065 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7183622e-01 7.1400428e-01 -6.0276599e+00 -1.2626915e+00 2.8305988e+01 6.1100769e+00

  20  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.306 2009  to  Fri Jan 23 17:13:04.306 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7128589e-01 7.1369600e-01 -6.0276809e+00 -1.2008553e+00 2.8357492e+01 6.0884018e+00

  21  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.551 2009  to  Fri Jan 23 17:13:04.551 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7128589e-01 7.1369600e-01 -6.0276809e+00 -1.2008553e+00 2.8357492e+01 6.0884018e+00

  22  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:04.806 2009  to  Fri Jan 23 17:13:04.806 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  23  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.059 2009  to  Fri Jan 23 17:13:05.059 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  24  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.313 2009  to  Fri Jan 23 17:13:05.313 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7078015e-01 7.1345150e-01 -6.0276990e+00 -1.1618080e+00 2.8289171e+01 6.0869102e+00

  25  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.567 2009  to  Fri Jan 23 17:13:05.567 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7163017e-01 7.1434319e-01 -6.0278788e+00 -1.1874428e+00 2.8320595e+01 6.0981064e+00

  26  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:05.808 2009  to  Fri Jan 23 17:13:05.808 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146572e-01 7.1401799e-01 -6.0280576e+00 -1.2835388e+00 2.8298912e+01 6.0666466e+00

  27  FAILED    PSF        primaryMirror.positionError                                   Fri Jan 23 17:13:06.052 2009  to  Fri Jan 23 17:13:06.052 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 2.7146572e-01 7.1401799e-01 -6.0280576e+00 -1.2835388e+00 2.8298912e+01 6.0666466e+00

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:06.960 2009  to  Fri Jan 23 17:13:06.960 2009   (  0.00) secs
                    EL bad poly no. 831052: BAD: poly EL = -5.467306e-01 rad. Too low.

  29  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:13:09.167 2009  to  Fri Jan 23 17:13:11.399 2009   (  2.23) secs
                    right PMC Mirror AutoRaise Command Failed because Raise never started

  30  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:09.976 2009  to  Fri Jan 23 17:13:09.976 2009   (  0.00) secs
                    EL bad poly no. 831099: BAD: poly EL = -5.466939e-01 rad. Too low.

  31  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:12.993 2009  to  Fri Jan 23 17:13:12.993 2009   (  0.00) secs
                    EL bad poly no. 831145: BAD: poly EL = -5.466571e-01 rad. Too low.

  32  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:15.994 2009  to  Fri Jan 23 17:13:15.994 2009   (  0.00) secs
                    EL bad poly no. 831191: BAD: poly EL = -5.466205e-01 rad. Too low.

  33  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:19.042 2009  to  Fri Jan 23 17:13:19.042 2009   (  0.00) secs
                    EL bad poly no. 831238: BAD: poly EL = -5.465832e-01 rad. Too low.

  34  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:22.071 2009  to  Fri Jan 23 17:13:22.071 2009   (  0.00) secs
                    EL bad poly no. 831285: BAD: poly EL = -5.465461e-01 rad. Too low.

  35  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:25.119 2009  to  Fri Jan 23 17:13:25.119 2009   (  0.00) secs
                    EL bad poly no. 831333: BAD: poly EL = -5.465088e-01 rad. Too low.

  36  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:28.130 2009  to  Fri Jan 23 17:13:28.130 2009   (  0.00) secs
                    EL bad poly no. 831380: BAD: poly EL = -5.464718e-01 rad. Too low.

  37  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:31.141 2009  to  Fri Jan 23 17:13:31.141 2009   (  0.00) secs
                    EL bad poly no. 831425: BAD: poly EL = -5.464349e-01 rad. Too low.

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:34.146 2009  to  Fri Jan 23 17:13:34.146 2009   (  0.00) secs
                    EL bad poly no. 831471: BAD: poly EL = -5.463979e-01 rad. Too low.

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:37.217 2009  to  Fri Jan 23 17:13:37.217 2009   (  0.00) secs
                    EL bad poly no. 831518: BAD: poly EL = -5.463601e-01 rad. Too low.

  40  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:40.246 2009  to  Fri Jan 23 17:13:40.246 2009   (  0.00) secs
                    EL bad poly no. 831565: BAD: poly EL = -5.463228e-01 rad. Too low.

  41  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:43.265 2009  to  Fri Jan 23 17:13:43.265 2009   (  0.00) secs
                    EL bad poly no. 831612: BAD: poly EL = -5.462855e-01 rad. Too low.

  42  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:46.310 2009  to  Fri Jan 23 17:13:46.310 2009   (  0.00) secs
                    EL bad poly no. 831659: BAD: poly EL = -5.462479e-01 rad. Too low.

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:49.319 2009  to  Fri Jan 23 17:13:49.319 2009   (  0.00) secs
                    EL bad poly no. 831706: BAD: poly EL = -5.462107e-01 rad. Too low.

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:52.349 2009  to  Fri Jan 23 17:13:52.349 2009   (  0.00) secs
                    EL bad poly no. 831753: BAD: poly EL = -5.461732e-01 rad. Too low.

  45  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:55.414 2009  to  Fri Jan 23 17:13:55.414 2009   (  0.00) secs
                    EL bad poly no. 831800: BAD: poly EL = -5.461352e-01 rad. Too low.

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:13:58.411 2009  to  Fri Jan 23 17:13:58.411 2009   (  0.00) secs
                    EL bad poly no. 831846: BAD: poly EL = -5.460980e-01 rad. Too low.

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:01.441 2009  to  Fri Jan 23 17:14:01.441 2009   (  0.00) secs
                    EL bad poly no. 831892: BAD: poly EL = -5.460604e-01 rad. Too low.

  48  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:04.477 2009  to  Fri Jan 23 17:14:04.477 2009   (  0.00) secs
                    EL bad poly no. 831939: BAD: poly EL = -5.460227e-01 rad. Too low.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:07.517 2009  to  Fri Jan 23 17:14:07.517 2009   (  0.00) secs
                    EL bad poly no. 831985: BAD: poly EL = -5.459848e-01 rad. Too low.

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:10.546 2009  to  Fri Jan 23 17:14:10.546 2009   (  0.00) secs
                    EL bad poly no. 832033: BAD: poly EL = -5.459471e-01 rad. Too low.

  51  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Fri Jan 23 17:14:13.605 2009  to  Fri Jan 23 17:14:13.605 2009   (  0.00) secs
                    EL bad poly no. 832081: BAD: poly EL = -5.459089e-01 rad. Too low.

  52  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:14:41.519 2009  to  Fri Jan 23 17:14:43.692 2009   (  2.17) secs
                    right PMC Mirror AutoRaise Command Failed because Raise never started

  53  FAILED    PMC        mirror.command.raise.auto                                     Fri Jan 23 17:14:53.933 2009  to  Fri Jan 23 17:14:56.201 2009   (  2.27) secs
                    left PMC Mirror AutoRaise Command Failed because Raise never started

  54  FAILED    PMC        mirror.panic                                                  Fri Jan 23 17:19:37.564 2009  to  Fri Jan 23 17:19:37.564 2009   (  0.00) secs
                    left PMC ** PANIC: User Button

  55  FAILED    PMC        mirror.panic                                                  Fri Jan 23 17:23:46.574 2009  to  Fri Jan 23 17:23:46.574 2009   (  0.00) secs
                    right PMC ** PANIC: User Button

  56  FAILED    PMC        actuator.getForce.readError                                   Fri Jan 23 17:23:46.881 2009  to  Fri Jan 23 17:23:46.881 2009   (  0.00) secs
                    right PMC Actuator 139 get force read error: -3

  57  FAILED    PMC        actuator.setForce.readError                                   Fri Jan 23 17:23:46.913 2009  to  Fri Jan 23 17:23:46.913 2009   (  0.00) secs
                    right PMC Actuator 107 set force read error: -3

  58  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:46.979 2009  to  Fri Jan 23 17:23:46.979 2009   (  0.00) secs
                    right PMC Actuator 123 has been reset

  59  FAILED    PMC        actuator.setForce.addressError                                Fri Jan 23 17:23:46.946 2009  to  Fri Jan 23 17:23:46.946 2009   (  0.00) secs
                    right PMC Actuator 112 set force bad return: 255 instead of 2

  60  FAILED    PMC        actuator.setForce.addressError                                Fri Jan 23 17:23:47.022 2009  to  Fri Jan 23 17:23:47.022 2009   (  0.00) secs
                    right PMC Actuator 130 set force bad return: 130 instead of 4

  61  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.065 2009  to  Fri Jan 23 17:23:47.065 2009   (  0.00) secs
                    right PMC Actuator 135 has been reset

  62  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.090 2009  to  Fri Jan 23 17:23:47.090 2009   (  0.00) secs
                    right PMC Actuator 134 has been reset

  63  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.139 2009  to  Fri Jan 23 17:23:47.139 2009   (  0.00) secs
                    right PMC Actuator 132 has been reset

  64  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.191 2009  to  Fri Jan 23 17:23:47.191 2009   (  0.00) secs
                    right PMC Actuator 133 has been reset

  65  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.219 2009  to  Fri Jan 23 17:23:47.219 2009   (  0.00) secs
                    right PMC Actuator 139 has been reset

  66  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.245 2009  to  Fri Jan 23 17:23:47.245 2009   (  0.00) secs
                    right PMC Actuator 136 has been reset

  67  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.271 2009  to  Fri Jan 23 17:23:47.271 2009   (  0.00) secs
                    right PMC Actuator 141 has been reset

  68  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.295 2009  to  Fri Jan 23 17:23:47.295 2009   (  0.00) secs
                    right PMC Actuator 124 has been reset

  69  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.322 2009  to  Fri Jan 23 17:23:47.322 2009   (  0.00) secs
                    right PMC Actuator 125 has been reset

  70  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.368 2009  to  Fri Jan 23 17:23:47.368 2009   (  0.00) secs
                    right PMC Actuator 131 has been reset

  71  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.392 2009  to  Fri Jan 23 17:23:47.392 2009   (  0.00) secs
                    right PMC Actuator 211 has been reset

  72  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.416 2009  to  Fri Jan 23 17:23:47.416 2009   (  0.00) secs
                    right PMC Actuator 207 has been reset

  73  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.443 2009  to  Fri Jan 23 17:23:47.443 2009   (  0.00) secs
                    right PMC Actuator 140 has been reset

  74  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.470 2009  to  Fri Jan 23 17:23:47.470 2009   (  0.00) secs
                    right PMC Actuator 215 has been reset

  75  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.496 2009  to  Fri Jan 23 17:23:47.496 2009   (  0.00) secs
                    right PMC Actuator 210 has been reset

  76  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.521 2009  to  Fri Jan 23 17:23:47.521 2009   (  0.00) secs
                    right PMC Actuator 126 has been reset

  77  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.546 2009  to  Fri Jan 23 17:23:47.546 2009   (  0.00) secs
                    right PMC Actuator 129 has been reset

  78  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.597 2009  to  Fri Jan 23 17:23:47.597 2009   (  0.00) secs
                    right PMC Actuator 138 has been reset

  79  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.620 2009  to  Fri Jan 23 17:23:47.620 2009   (  0.00) secs
                    right PMC Actuator 213 has been reset

  80  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.645 2009  to  Fri Jan 23 17:23:47.645 2009   (  0.00) secs
                    right PMC Actuator 218 has been reset

  81  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.669 2009  to  Fri Jan 23 17:23:47.669 2009   (  0.00) secs
                    right PMC Actuator 209 has been reset

  82  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.695 2009  to  Fri Jan 23 17:23:47.695 2009   (  0.00) secs
                    right PMC Actuator 231 has been reset

  83  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.721 2009  to  Fri Jan 23 17:23:47.721 2009   (  0.00) secs
                    right PMC Actuator 228 has been reset

  84  FAILED    PMC        actuator.reset                                                Fri Jan 23 17:23:47.748 2009  to  Fri Jan 23 17:23:47.748 2009   (  0.00) secs
                    right PMC Actuator 142 has been reset

  85  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:35:25.346 2009  to  Fri Jan 23 17:35:25.346 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  86  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:35:26.020 2009  to  Fri Jan 23 17:35:26.020 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  87  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:38:20.109 2009  to  Fri Jan 23 17:38:20.109 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  88  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan 23 17:38:21.531 2009  to  Fri Jan 23 17:38:21.531 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  89  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.514 2009  to  Fri Jan 23 17:47:44.514 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  90  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.515 2009  to  Fri Jan 23 17:47:44.515 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  91  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.516 2009  to  Fri Jan 23 17:47:44.516 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  92  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.517 2009  to  Fri Jan 23 17:47:44.517 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  93  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.544 2009  to  Fri Jan 23 17:47:44.544 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  94  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.545 2009  to  Fri Jan 23 17:47:44.545 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  95  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.546 2009  to  Fri Jan 23 17:47:44.546 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  96  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 17:47:44.546 2009  to  Fri Jan 23 17:47:44.546 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  97  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jan 23 17:47:44.767 2009  to  Fri Jan 23 17:47:44.767 2009   (  0.00) secs
                    LFT StowIdleIn: stowpin is moving but hasn't been commanded to move.

  98  FAILED    MCS.MCSPU  MCSPU.ELDrive.Stowpins.stowpinMoving                          Fri Jan 23 17:47:45.153 2009  to  Fri Jan 23 17:47:45.153 2009   (  0.00) secs
                    RT StowIdleIn: stowpin is moving but hasn't been commanded to move.

  99  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Jan 23 17:53:24.755 2009  to  Fri Jan 23 17:53:24.755 2009   (  0.00) secs
                    left PMC Actuator 328 force monitor 2 PANIC! 275.6 lbs, limit is 143.8

 100  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jan 23 17:55:01.975 2009  to  Fri Jan 23 17:55:01.975 2009   (  0.00) secs
                    Master Ctrl Relay has opened because EL MCR is off: EL locked out!

 101  FAILED    MCS.MCSPU  MCSPU.ELDrive.mcrProblem                                      Fri Jan 23 17:55:02.112 2009  to  Fri Jan 23 17:55:02.112 2009   (  0.00) secs
                    Master Ctrl Relay has opened because EL MCR is off: EL locked out!

 102  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 18:50:26.217 2009  to  Fri Jan 23 18:50:26.217 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 103  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 18:50:26.222 2009  to  Fri Jan 23 18:50:26.222 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 104  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 18:50:26.313 2009  to  Fri Jan 23 18:50:26.313 2009   (  0.00) secs
                    drive cabinet has turned on.

 105  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.838 2009  to  Fri Jan 23 18:50:26.838 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 106  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.838 2009  to  Fri Jan 23 18:50:26.838 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 107  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.839 2009  to  Fri Jan 23 18:50:26.839 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 108  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.840 2009  to  Fri Jan 23 18:50:26.840 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 109  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.842 2009  to  Fri Jan 23 18:50:26.842 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 110  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.842 2009  to  Fri Jan 23 18:50:26.842 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 111  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.843 2009  to  Fri Jan 23 18:50:26.843 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 112  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 18:50:26.844 2009  to  Fri Jan 23 18:50:26.844 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 113  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:50.935 2009  to  Fri Jan 23 19:26:50.935 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 1 times

 114  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:51.970 2009  to  Fri Jan 23 19:26:51.970 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 2 times

 115  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:53.004 2009  to  Fri Jan 23 19:26:53.004 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 3 times

 116  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:54.046 2009  to  Fri Jan 23 19:26:54.046 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 4 times

 117  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:55.088 2009  to  Fri Jan 23 19:26:55.088 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 5 times

 118  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:56.132 2009  to  Fri Jan 23 19:26:56.132 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 6 times

 119  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:57.174 2009  to  Fri Jan 23 19:26:57.174 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 7 times

 120  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:58.217 2009  to  Fri Jan 23 19:26:58.217 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 8 times

 121  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:26:59.258 2009  to  Fri Jan 23 19:26:59.258 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 9 times

 122  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:00.306 2009  to  Fri Jan 23 19:27:00.306 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 10 times

 123  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:01.345 2009  to  Fri Jan 23 19:27:01.345 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 11 times

 124  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:02.393 2009  to  Fri Jan 23 19:27:02.393 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 12 times

 125  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:03.456 2009  to  Fri Jan 23 19:27:03.456 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 13 times

 126  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:04.498 2009  to  Fri Jan 23 19:27:04.498 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 14 times

 127  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:05.555 2009  to  Fri Jan 23 19:27:05.555 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 15 times

 128  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:06.589 2009  to  Fri Jan 23 19:27:06.589 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 16 times

 129  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:07.620 2009  to  Fri Jan 23 19:27:07.620 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 17 times

 130  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:08.657 2009  to  Fri Jan 23 19:27:08.657 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 18 times

 131  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:09.697 2009  to  Fri Jan 23 19:27:09.697 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 19 times

 132  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:10.729 2009  to  Fri Jan 23 19:27:10.729 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 20 times

 133  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:11.775 2009  to  Fri Jan 23 19:27:11.775 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 21 times

 134  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:12.810 2009  to  Fri Jan 23 19:27:12.810 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 22 times

 135  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:13.846 2009  to  Fri Jan 23 19:27:13.846 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 23 times

 136  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:14.890 2009  to  Fri Jan 23 19:27:14.890 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 24 times

 137  FAILED    MCS.MCSPU  MCSPU.ERPlcDevice.readError                                   Fri Jan 23 19:27:15.929 2009  to  Fri Jan 23 19:27:15.929 2009   (  0.00) secs
                    ERPLC read produced an error (bad read size) 25 times

 138  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 19:32:57.764 2009  to  Fri Jan 23 19:32:57.764 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 139  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 19:32:57.771 2009  to  Fri Jan 23 19:32:57.771 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 140  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 19:32:57.858 2009  to  Fri Jan 23 19:32:57.858 2009   (  0.00) secs
                    drive cabinet has turned on.

 141  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.370 2009  to  Fri Jan 23 19:32:58.370 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 142  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.370 2009  to  Fri Jan 23 19:32:58.370 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 143  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.371 2009  to  Fri Jan 23 19:32:58.371 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 144  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.372 2009  to  Fri Jan 23 19:32:58.372 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 145  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.373 2009  to  Fri Jan 23 19:32:58.373 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 146  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.374 2009  to  Fri Jan 23 19:32:58.374 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 147  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.375 2009  to  Fri Jan 23 19:32:58.375 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 148  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 19:32:58.376 2009  to  Fri Jan 23 19:32:58.376 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 149  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 19:55:26.031 2009  to  Fri Jan 23 19:55:26.031 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 150  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 19:55:26.016 2009  to  Fri Jan 23 19:55:26.016 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 151  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 19:55:25.984 2009  to  Fri Jan 23 19:55:25.984 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 152  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 21:04:10.973 2009  to  Fri Jan 23 21:04:10.973 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 153  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 21:04:10.957 2009  to  Fri Jan 23 21:04:10.957 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 154  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 21:04:10.937 2009  to  Fri Jan 23 21:04:10.937 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 155  FAILED    ECS        plc.read.failed                                               Fri Jan 23 21:18:19.411 2009  to  Fri Jan 23 21:18:19.411 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :SD1001_POSITION

 156  FAILED    ECS        plc.writeHS.failed                                            Fri Jan 23 21:18:19.412 2009  to  Fri Jan 23 21:18:19.412 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 4.5831348e+01, because PLC Read Failed

 157  FAILED    ECS        plc.writeHS.failed                                            Fri Jan 23 21:18:19.412 2009  to  Fri Jan 23 21:18:19.412 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 4.5831348e+01, because PLC Read Failed

 158  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:34.141 2009  to  Fri Jan 23 21:27:34.141 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 159  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:50.729 2009  to  Fri Jan 23 21:27:50.729 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 160  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:50.756 2009  to  Fri Jan 23 21:27:50.756 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 161  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:27:52.809 2009  to  Fri Jan 23 21:27:52.809 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 162  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:28:01.392 2009  to  Fri Jan 23 21:28:01.392 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 163  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 21:29:12.140 2009  to  Fri Jan 23 21:29:12.140 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 164  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 21:29:39.797 2009  to  Fri Jan 23 21:29:39.797 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 165  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 21:30:01.784 2009  to  Fri Jan 23 21:30:01.784 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 166  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan 23 21:44:57.906 2009  to  Fri Jan 23 21:45:04.129 2009   (  6.22) secs
                    right PSF SetInstrumentOffsets failed

 167  FAILED    IIF        command.moveFocus                                             Fri Jan 23 21:44:57.870 2009  to  Fri Jan 23 21:45:04.205 2009   (  6.33) secs
                    IIF MoveFocus command started for right LBC for 8.100000000000000e-02
                    IIF MoveFocus alert for right LBC: Primary mirror collimation reached limit
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for 8.100000000000000e-02

 168  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan 23 21:44:57.970 2009  to  Fri Jan 23 21:45:04.016 2009   (  6.05) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

 169  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan 23 21:44:57.941 2009  to  Fri Jan 23 21:45:04.063 2009   (  6.12) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

 170  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan 23 21:44:57.924 2009  to  Fri Jan 23 21:45:04.091 2009   (  6.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 171  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:07:35.264 2009  to  Fri Jan 23 22:07:35.264 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 172  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:07:52.549 2009  to  Fri Jan 23 22:07:52.549 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 173  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:08:23.885 2009  to  Fri Jan 23 22:08:23.885 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 174  FAILED    MCS.MCSPU  MCSPU.HydrostaticBearing.HBS_on_fail                          Fri Jan 23 22:12:11.613 2009  to  Fri Jan 23 22:12:11.613 2009   (  0.00) secs
                    The HBS_On_sm state machine timed out waiting for the HBS to turn on.

 175  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 22:13:06.098 2009  to  Fri Jan 23 22:13:06.098 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 176  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan 23 22:13:06.103 2009  to  Fri Jan 23 22:13:06.103 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 177  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan 23 22:13:06.191 2009  to  Fri Jan 23 22:13:06.191 2009   (  0.00) secs
                    drive cabinet has turned on.

 178  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan 23 22:13:06.714 2009  to  Fri Jan 23 22:13:06.714 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

 179  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan 23 23:07:34.324 2009  to  Fri Jan 23 23:07:34.324 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 180  FAILED    PMC        thermal.badReceive                                            Fri Jan 23 23:07:34.354 2009  to  Fri Jan 23 23:07:34.354 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 181  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan 23 23:07:34.339 2009  to  Fri Jan 23 23:07:34.339 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 182  FAILED    PMC        actuator.forceMonitor1.panic                                  Fri Jan 23 23:21:11.639 2009  to  Fri Jan 23 23:21:11.639 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 1 PANIC! -322.6 lbs, limit is 0.0

 183  FAILED    PMC        actuator.forceMonitor2.panic                                  Fri Jan 23 23:21:11.690 2009  to  Fri Jan 23 23:21:11.690 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 2 PANIC! 514.7 lbs, limit is 0.0

 184  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan 24 05:25:51.519 2009  to  Sat Jan 24 05:25:51.519 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 185  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan 24 05:25:51.504 2009  to  Sat Jan 24 05:25:51.504 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 186  FAILED    PMC        thermal.badReceive                                            Sat Jan 24 05:25:51.531 2009  to  Sat Jan 24 05:25:51.531 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 187  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan 24 06:49:01.118 2009  to  Sat Jan 24 06:49:01.118 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 188  FAILED    PMC        thermal.badReceive                                            Sat Jan 24 06:49:01.156 2009  to  Sat Jan 24 06:49:01.156 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 189  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan 24 06:49:01.139 2009  to  Sat Jan 24 06:49:01.139 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

**********************************************************
    Reporting period ending:   Sat Jan 24 07:48:59.881 2009
********************************************************************************************************

This topic: Software > TCSSWReportFile_090123
Topic revision: 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback