You are here: Foswiki>Software Web>TCSSWReportFile_090119 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jan 19 2009 to Jan 20 2009
 
    Reporting period beginning:   Mon Jan 19 17:09:04.236 2009
    Reporting period ending:      Tue Jan 20 07:50:59.929 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.ELDrive.commandReceived,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.01    0.03    0.02    0.05   100.0 %        134        134                      
                                                                       0.01    0.03    0.02    0.05
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.07    0.22    0.14    0.61   100.0 %        262        262                      
                                                                       0.07    0.22    0.14    0.61
     command.guide. . . . . . . . . . . . . . . . . . . . . . . . .    0.03    0.09    0.06    0.16   100.0 %         11         11                      
                                                                       0.03    0.09    0.06    0.16
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.01    5.07    0.36   19.46    97.5 %        238        232          6           
                                                                       3.99    5.19    2.26   19.46
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   38.14   49.25    0.00  173.25    88.1 %         42         37          5           
                                                                      32.92   50.16    6.92  125.38
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    3.87    9.98    0.51   27.64   100.0 %        143        143                      
                                                                       3.87    9.98    0.51   27.64

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 18:48:43.875 2009  to  Mon Jan 19 18:51:37.126 2009   (173.25) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485107549768518e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                    IIF Preset command failed for both LBC mode TRACK from IIF

   2  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:00:46.121 2009  to  Mon Jan 19 19:00:46.484 2009   (  0.36) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   3  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 19:06:30.938 2009  to  Mon Jan 19 19:06:43.084 2009   ( 12.15) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485108784722222e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                    IIF Preset command failed for both LBC mode TRACK from IIF

   4  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:40:39.387 2009  to  Mon Jan 19 19:40:39.834 2009   (  0.45) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   5  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:44:01.865 2009  to  Mon Jan 19 19:44:02.304 2009   (  0.44) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 20:04:54.233 2009  to  Mon Jan 19 20:05:43.266 2009   ( 49.03) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485112840277778e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset command failed for both LBC mode TRACK from IIF

   7  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 20:05:58.905 2009  to  Mon Jan 19 20:06:10.903 2009   ( 12.00) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485112914351852e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF Preset command failed for both LBC mode TRACK from IIF

   8  FAILED    IIF        command.moveFocus                                             Mon Jan 19 20:13:06.767 2009  to  Mon Jan 19 20:13:07.226 2009   (  0.46) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485113409722222e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   9  FAILED    IIF        command.moveFocus                                             Mon Jan 19 23:02:53.129 2009  to  Mon Jan 19 23:02:53.776 2009   (  0.65) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  10  FAILED    IIF        command.moveFocus                                             Mon Jan 19 23:02:53.140 2009  to  Mon Jan 19 23:02:53.859 2009   (  0.72) secs
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  11  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jan 19 23:34:59.332 2009  to  Mon Jan 19 23:36:08.422 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

  12  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 23:36:08.422 2009  to  Mon Jan 19 23:36:24.471 2009   ( 16.05) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485127509259259e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset command failed for both LBC mode TRACK from IIF

  13  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jan 19 23:36:31.400 2009  to  Mon Jan 19 23:36:31.400 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command complete for both LBC mode TRACK from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4528                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  9055          1           
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                    11                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     347                      
     plc.read.failed. . . . . . . . . . . . . . . . . . . . . . . .                  1           
     plc.writeHS.failed . . . . . . . . . . . . . . . . . . . . . .                  3           

ECS Events of Interest

   1  FAILED    ECS        plc.read.failed                                               Tue Jan 20 01:55:18.919 2009  to  Tue Jan 20 01:55:18.919 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :Local:10:I

   2  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 3.5353699e+01, because PLC Read Failed

   3  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 3.5353699e+01, because PLC Read Failed

   4  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_LEFT, value 3.5755402e+01, because PLC Read Failed

   5  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue Jan 20 01:55:19.010 2009  to  Tue Jan 20 01:55:19.010 2009   (  0.00) secs
                    Instrument cooling command set temperature set pt failed:temp 2.0863335e+00
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                         
      Nothing to report

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       8                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .       7                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.OpticalSupport.commandReceived . . . . . . . . . . . . .       7                      
     MCSPU.Side.doingCommand. . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      32                      
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      29                      
     MCSPU.SwingArm.startingRetract . . . . . . . . . . . . . . . .       3                      
     MCSPU.OpticalSupport.badCommandReceived. . . . . . . . . . . .                  2           
     MCSPU.OpticalSupport.commandActionReceived . . . . . . . . . .       3                      
     MCSPU.Side.completedCommand. . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Side.spontaneousHalt . . . . . . . . . . . . . . . . . .                             1
     MCSPU.SwingArm.startingDeploy. . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.commandCompletion . . . . . . . . . . . . . . .       3                      
     MCSPU.SwingArm.deployRetractResult . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.HBS_on_successful . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             5
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             4
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            21
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      34                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      16                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .      18                      
     MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 16           
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       2                     1
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       2                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.HydrostaticBearing.alarm . . . . . . . . . . . . . . . .                             1
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      13                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      84                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.badCommandReceived                       Mon Jan 19 17:13:55.284 2009  to  Mon Jan 19 17:13:55.284 2009   (  0.00) secs
                    Received a powerSA command with BAD arguments = left pf

   2  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.badCommandReceived                       Mon Jan 19 17:29:31.636 2009  to  Mon Jan 19 17:29:31.636 2009   (  0.00) secs
                    Received a powerSA command with BAD arguments = left right

   3  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.626 2009  to  Mon Jan 19 17:37:12.626 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.626 2009  to  Mon Jan 19 17:37:12.626 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.627 2009  to  Mon Jan 19 17:37:12.627 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.627 2009  to  Mon Jan 19 17:37:12.627 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.628 2009  to  Mon Jan 19 17:37:12.628 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.629 2009  to  Mon Jan 19 17:37:12.629 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.629 2009  to  Mon Jan 19 17:37:12.629 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.630 2009  to  Mon Jan 19 17:37:12.630 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Mon Jan 19 17:47:11.965 2009  to  Mon Jan 19 17:47:11.965 2009   (  0.00) secs
                    

  12  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.601 2009  to  Mon Jan 19 17:50:44.601 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  13  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.602 2009  to  Mon Jan 19 17:50:44.602 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.603 2009  to  Mon Jan 19 17:50:44.603 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.603 2009  to  Mon Jan 19 17:50:44.603 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.604 2009  to  Mon Jan 19 17:50:44.604 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.604 2009  to  Mon Jan 19 17:50:44.604 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.605 2009  to  Mon Jan 19 17:50:44.605 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.606 2009  to  Mon Jan 19 17:50:44.606 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  20  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Mon Jan 19 17:50:54.019 2009  to  Mon Jan 19 17:50:54.019 2009   (  0.00) secs
                    
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest

   1  SHUTDOWN  OSS        shutdown                                                      Mon Jan 19 19:57:46.229 2009  to  Mon Jan 19 19:57:46.229 2009   (  0.00) secs
                    The oss was shut down.

   2  STARTUP   OSS        startup                                                       Mon Jan 19 19:58:24.358 2009  to  Mon Jan 19 19:58:24.358 2009   (  0.00) secs
                    The oss was started.
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.setCentroid . . . . . . . . . . . . . . . . . .    0.01    0.02    0.01    0.04   100.0 %         11         11                      
                                                                       0.01    0.02    0.01    0.04
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.02    0.10    0.07    0.18   100.0 %        262        262                      
                                                                       0.02    0.10    0.07    0.18
     telescope.command.listAuthorizedPMTerms. . . . . . . . . . . .    0.00    0.01    0.01    0.01   100.0 %          2          2                      
                                                                       0.00    0.01    0.01    0.01
     telescope.command.setAuthorizedPMTerm. . . . . . . . . . . . .    0.01    0.02    0.01    0.02   100.0 %          4          4                      
                                                                       0.01    0.02    0.01    0.02
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.03    0.04    0.02    0.15   100.0 %         42         42                      
                                                                       0.03    0.04    0.02    0.15
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.30    0.44    0.00    0.78   100.0 %         42         42                      
                                                                       0.12    0.62    0.52    0.78

PCS Single Event Activity                                          
      Nothing to report

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 21:54:04.228 2009  to  Mon Jan 19 21:55:45.709 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   2  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 21:54:04.499 2009  to  Mon Jan 19 21:54:04.499 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   3  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 22:55:11.556 2009  to  Mon Jan 19 23:02:16.835 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 22:55:11.826 2009  to  Mon Jan 19 22:55:11.826 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:02:16.835 2009  to  Mon Jan 19 23:10:53.660 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   6  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:02:17.148 2009  to  Mon Jan 19 23:02:17.148 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   7  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:24:43.790 2009  to  Mon Jan 19 23:34:59.446 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:24:44.120 2009  to  Mon Jan 19 23:24:44.120 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:57:58.606 2009  to  Tue Jan 20 00:03:32.682 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:57:58.913 2009  to  Mon Jan 19 23:57:58.913 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:44:53.099 2009  to  Tue Jan 20 00:53:22.971 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:44:53.372 2009  to  Tue Jan 20 00:44:53.372 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:53:22.971 2009  to  Tue Jan 20 01:03:40.810 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:53:23.241 2009  to  Tue Jan 20 00:53:23.241 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:03:40.810 2009  to  Tue Jan 20 01:05:03.278 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:03:41.083 2009  to  Tue Jan 20 01:03:41.083 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  17  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:15:45.837 2009  to  Tue Jan 20 01:25:14.195 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  18  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:15:46.107 2009  to  Tue Jan 20 01:15:46.107 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  19  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 02:00:38.453 2009  to  Tue Jan 20 02:08:24.566 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  20  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 02:00:38.749 2009  to  Tue Jan 20 02:00:38.749 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  21  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 04:34:10.597 2009  to  Tue Jan 20 05:05:00.696 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  22  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 04:34:10.882 2009  to  Tue Jan 20 04:34:10.882 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  23  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 05:05:00.696 2009  to  Tue Jan 20 05:14:38.962 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  24  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 05:05:00.965 2009  to  Tue Jan 20 05:05:00.965 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.00    1.02    1.02    1.02   100.0 %          1          1                      
                                                                       0.00    1.02    1.02    1.02
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.26    2.54    2.02   10.05   100.0 %        146        146                      
                                                                       1.26    2.54    2.02   10.05
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    2.55    4.04    2.02    8.03   100.0 %          5          5                      
                                                                       2.55    4.04    2.02    8.03
     command.shutDown . . . . . . . . . . . . . . . . . . . . . . .    0.00    0.28    0.28    0.28   100.0 %          1          1                      
                                                                       0.00    0.28    0.28    0.28
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.00    2.05    2.05    2.05   100.0 %          1          1                      
                                                                       0.00    2.05    2.05    2.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .    9.79    7.52    0.00   91.19    98.4 %        514        506          8           
                                                                       9.85    7.69    2.02   91.19
     mirror.command.lower.auto. . . . . . . . . . . . . . . . . . .    0.00  169.36  169.36  169.36   100.0 %          1          1                      
                                                                       0.00  169.36  169.36  169.36
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  138.41  138.41  138.41   100.0 %          1          1                      
                                                                       0.00  138.41  138.41  138.41
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.08    0.08    0.08   100.0 %          1          1                      
                                                                       0.00    0.08    0.08    0.08

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                             6
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             2
     actuator.forceMonitor1.warning . . . . . . . . . . . . . . . .                             1
     actuator.forceMonitor1.panic . . . . . . . . . . . . . . . . .                  1           
     actuator.forceMonitor2.warning . . . . . . . . . . . . . . . .                             1
     actuator.forceMonitor2.panic . . . . . . . . . . . . . . . . .                  1           
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  2           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  2           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  2           
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       5                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .     146                      
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      39                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       3                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       3                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       3                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       3                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       3                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       3                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                             2
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       3                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       3                      
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 29           
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            26
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            99
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.lower . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.down. . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                          2148
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                          2148
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 19           

PMC Events of Interest

   1  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Jan 19 17:39:29.645 2009  to  Mon Jan 19 17:39:29.645 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 1 PANIC! -171.3 lbs, limit is 0.0

   2  FAILED    PMC        actuator.forceMonitor2.panic                                  Mon Jan 19 17:39:29.695 2009  to  Mon Jan 19 17:39:29.695 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 2 PANIC! 447.8 lbs, limit is 0.0

   3  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 19 18:22:28.322 2009  to  Mon Jan 19 18:22:28.322 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   4  FAILED    PMC        thermal.badReceive                                            Mon Jan 19 18:22:28.378 2009  to  Mon Jan 19 18:22:28.378 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   5  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 19 18:22:28.351 2009  to  Mon Jan 19 18:22:28.351 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

   6  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 19:39:21.256 2009  to  Mon Jan 19 19:39:29.293 2009   (  8.04) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   7  FAILED    PMC        actuator.telemetryError                                       Mon Jan 19 19:47:26.271 2009  to  Mon Jan 19 19:47:26.271 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   8  STARTUP   PMC        startup                                                       Mon Jan 19 19:47:29.631 2009  to  Mon Jan 19 19:47:29.631 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

   9  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.717 2009  to  Mon Jan 19 19:57:51.717 2009   (  0.00) secs
                    right PMC PMC closing network connection

  10  SHUTDOWN  PMC        shutdown                                                      Mon Jan 19 19:57:51.693 2009  to  Mon Jan 19 19:57:51.693 2009   (  0.00) secs
                    right PMC subsystem shut down

  11  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.756 2009  to  Mon Jan 19 19:57:51.756 2009   (  0.00) secs
                    right PMC PMCLogger closing network connection

  12  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.775 2009  to  Mon Jan 19 19:57:51.775 2009   (  0.00) secs
                    right PMC Async closing network connection

  13  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.831 2009  to  Mon Jan 19 19:57:51.831 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  14  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.850 2009  to  Mon Jan 19 19:57:51.850 2009   (  0.00) secs
                    right PMC Mount closing network connection

  15  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.908 2009  to  Mon Jan 19 19:57:51.908 2009   (  0.00) secs
                    right PMC Mirror closing network connection

  16  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.950 2009  to  Mon Jan 19 19:57:51.950 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  17  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.992 2009  to  Mon Jan 19 19:57:51.992 2009   (  0.00) secs
                    right PMC Motor closing network connection

  18  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:52.046 2009  to  Mon Jan 19 19:57:52.046 2009   (  0.00) secs
                    right PMC AirPressure closing network connection

  19  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:52.073 2009  to  Mon Jan 19 19:57:52.073 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  20  FAILED    PMC        actuator.telemetryError                                       Mon Jan 19 19:58:15.313 2009  to  Mon Jan 19 19:58:15.313 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  21  STARTUP   PMC        startup                                                       Mon Jan 19 19:58:18.533 2009  to  Mon Jan 19 19:58:18.533 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

  22  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:05:22.056 2009  to  Mon Jan 19 20:05:22.093 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  23  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:06:06.684 2009  to  Mon Jan 19 20:06:06.720 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  24  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:12:14.727 2009  to  Mon Jan 19 20:13:06.976 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  25  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:13:06.976 2009  to  Mon Jan 19 20:13:07.005 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:13:18.874 2009  to  Mon Jan 19 20:13:18.874 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  27  FAILED    PMC        VxInterface.close                                             Mon Jan 19 21:44:21.683 2009  to  Mon Jan 19 21:44:21.683 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  28  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 21:44:21.662 2009  to  Mon Jan 19 21:44:21.662 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  29  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 19 22:30:36.359 2009  to  Mon Jan 19 22:30:36.359 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  30  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 19 22:30:36.340 2009  to  Mon Jan 19 22:30:36.340 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  31  FAILED    PMC        thermal.badReceive                                            Mon Jan 19 22:30:36.377 2009  to  Mon Jan 19 22:30:36.377 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  32  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 22:45:57.459 2009  to  Mon Jan 19 22:45:57.459 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Mon Jan 19 22:45:57.481 2009  to  Mon Jan 19 22:45:57.481 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  34  FAILED    PMC        VxInterface.close                                             Mon Jan 19 22:50:54.836 2009  to  Mon Jan 19 22:50:54.836 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  35  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 22:50:54.817 2009  to  Mon Jan 19 22:50:54.817 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  36  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:42.304 2009  to  Mon Jan 19 23:02:53.335 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  37  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:42.315 2009  to  Mon Jan 19 23:02:53.368 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  38  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:53.335 2009  to  Mon Jan 19 23:02:53.390 2009   (  0.06) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  39  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:53.368 2009  to  Mon Jan 19 23:02:53.420 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  40  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:55.382 2009  to  Mon Jan 19 23:02:55.382 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  41  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:03:00.403 2009  to  Mon Jan 19 23:03:00.403 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  42  FAILED    PMC        VxInterface.close                                             Mon Jan 19 23:10:17.399 2009  to  Mon Jan 19 23:10:17.399 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  43  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 23:10:17.380 2009  to  Mon Jan 19 23:10:17.380 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  44  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:35:43.167 2009  to  Mon Jan 19 23:36:24.220 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  45  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:35:43.183 2009  to  Mon Jan 19 23:36:24.234 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  46  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:24.220 2009  to  Mon Jan 19 23:36:24.256 2009   (  0.04) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  47  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:24.234 2009  to  Mon Jan 19 23:36:24.278 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:28.300 2009  to  Mon Jan 19 23:36:28.300 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

  49  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:29.282 2009  to  Mon Jan 19 23:36:29.282 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  50  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:05:41.606 2009  to  Tue Jan 20 01:05:41.606 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:05:41.586 2009  to  Tue Jan 20 01:05:41.586 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  52  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:15:54.294 2009  to  Tue Jan 20 01:15:54.294 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  53  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:15:54.317 2009  to  Tue Jan 20 01:15:54.317 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  54  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:51:14.243 2009  to  Tue Jan 20 01:51:14.243 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:51:14.219 2009  to  Tue Jan 20 01:51:14.219 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:00:46.906 2009  to  Tue Jan 20 02:00:46.906 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:00:46.885 2009  to  Tue Jan 20 02:00:46.885 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:14:11.582 2009  to  Tue Jan 20 02:14:11.582 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  59  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:14:11.563 2009  to  Tue Jan 20 02:14:11.563 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  60  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:29:12.194 2009  to  Tue Jan 20 02:29:12.194 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  61  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:29:12.175 2009  to  Tue Jan 20 02:29:12.175 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  62  FAILED    PMC        VxInterface.close                                             Tue Jan 20 03:49:42.370 2009  to  Tue Jan 20 03:49:42.370 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  63  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 03:49:42.346 2009  to  Tue Jan 20 03:49:42.346 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  64  FAILED    PMC        VxInterface.close                                             Tue Jan 20 03:55:40.263 2009  to  Tue Jan 20 03:55:40.263 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  65  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 03:55:40.241 2009  to  Tue Jan 20 03:55:40.241 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  66  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:07:39.832 2009  to  Tue Jan 20 04:07:39.832 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:07:39.850 2009  to  Tue Jan 20 04:07:39.850 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  68  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:11:47.355 2009  to  Tue Jan 20 04:11:47.355 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  69  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:11:47.334 2009  to  Tue Jan 20 04:11:47.334 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  70  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:49:01.228 2009  to  Tue Jan 20 04:49:01.228 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  71  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:49:01.208 2009  to  Tue Jan 20 04:49:01.208 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  72  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:57:56.227 2009  to  Tue Jan 20 04:57:56.227 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

  73  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:08:21.132 2009  to  Tue Jan 20 05:08:21.132 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  74  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:58:27.822 2009  to  Tue Jan 20 05:58:27.822 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  75  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:59:49.910 2009  to  Tue Jan 20 05:59:49.910 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96
**********************************************************
PSF Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.adjustPointing . . . . . . . . . . . . . . . . . . . .    6.28   14.88    3.23   30.42   100.0 %         14         14                      
                                                                       6.28   14.88    3.23   30.42
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    3.87    9.83    0.26   27.47   100.0 %        143        143                      
                                                                       3.87    9.83    0.26   27.47
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.01    4.96    0.21   19.28    97.5 %        238        232          6           
                                                                       3.99    5.08    2.19   19.28
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    3.87    9.89    0.31   27.56   100.0 %        143        143                      
                                                                       3.87    9.89    0.31   27.56
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    5.52   10.56    0.16   48.89    99.4 %        165        164          1           
                                                                       5.22   10.42    0.16   48.89
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    9.76    7.50    0.00   91.28    96.9 %        522        506         16           
                                                                       9.85    7.79    2.08   91.28
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.00    2.13    2.13    2.13   100.0 %          1          1                      
                                                                       0.00    2.13    2.13    2.13
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    2.81    4.63    2.09    9.26   100.0 %          5          5                      
                                                                       2.81    4.63    2.09    9.26
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.13    0.08    0.03    2.02   100.0 %        387        387                      
                                                                       0.13    0.08    0.03    2.02
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.28    0.24    0.03    0.61   100.0 %          5          5                      
                                                                       0.28    0.24    0.03    0.61
     primaryMirror.command.initModesGains . . . . . . . . . . . . .    0.22    1.88    1.72    2.04   100.0 %          2          2                      
                                                                       0.22    1.88    1.72    2.04
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    4.08   10.03    5.27   15.37   100.0 %          5          5                      
                                                                       4.08   10.03    5.27   15.37
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    5.51   11.21    5.16   17.19   100.0 %          4          4                      
                                                                       5.51   11.21    5.16   17.19
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.01    4.88    0.11   19.22    97.5 %        238        232          6           
                                                                       3.99    5.00    2.13   19.22
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.03    0.02    0.06   100.0 %         23         23                      
                                                                       0.01    0.03    0.02    0.06
     primaryMirror.command.setPointingOffsets . . . . . . . . . . .    6.03   14.35    3.16   30.35   100.0 %         16         16                      
                                                                       6.03   14.35    3.16   30.35
     primaryMirror.command.setSecondaryOffload. . . . . . . . . . .    0.00    6.16    6.16    6.16   100.0 %          1          1                      
                                                                       0.00    6.16    6.16    6.16
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.03    0.02    0.13   100.0 %        166        166                      
                                                                       0.01    0.03    0.02    0.13
     secondaryMirror.command.initGains. . . . . . . . . . . . . . .    0.11    1.53    1.45    1.61   100.0 %          2          2                      
                                                                       0.11    1.53    1.45    1.61
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.20    1.23    1.09    1.37   100.0 %          2          2                      
                                                                       0.20    1.23    1.09    1.37
     tertiaryMirror.command.initGains . . . . . . . . . . . . . . .    0.01    0.07    0.07    0.08   100.0 %          2          2                      
                                                                       0.01    0.07    0.07    0.08
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.18    0.95    0.82    1.07   100.0 %          2          2                      
                                                                       0.18    0.95    0.82    1.07

PSF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** primaryMirror.positionError. . . . . . . . . . . . . . . . . .              26590           

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 18:50:05.775 2009  to  Mon Jan 19 18:50:05.834 2009   (  0.06) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

   2  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:37.008 2009  to  Mon Jan 19 19:00:37.008 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

   3  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:39.856 2009  to  Mon Jan 19 19:00:39.856 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.5924397e-04 -1.1770725e-03 3.3580065e-03 -2.0450592e-02 3.7883759e-02 3.3767223e-03

   4  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.079 2009  to  Mon Jan 19 19:00:40.079 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.5924397e-04 -1.1770725e-03 3.3580065e-03 -2.0450592e-02 3.7883759e-02 3.3767223e-03

   5  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.717 2009  to  Mon Jan 19 19:00:40.717 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.4970384e-04 -7.9417229e-04 3.1224489e-03 -1.1938095e-02 9.7084045e-03 -9.9670887e-03

   6  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.941 2009  to  Mon Jan 19 19:00:40.941 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.4970384e-04 -7.9417229e-04 3.1224489e-03 -1.1938095e-02 9.7084045e-03 -9.9670887e-03

   7  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:43.218 2009  to  Mon Jan 19 19:00:43.218 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

   8  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:43.442 2009  to  Mon Jan 19 19:00:43.442 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

   9  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:00:46.186 2009  to  Mon Jan 19 19:00:46.392 2009   (  0.21) secs
                    right PSF SetInstrumentOffsets failed

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:00:46.272 2009  to  Mon Jan 19 19:00:46.313 2009   (  0.04) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  11  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:00:46.240 2009  to  Mon Jan 19 19:00:46.353 2009   (  0.11) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  12  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:06:39.905 2009  to  Mon Jan 19 19:06:39.939 2009   (  0.03) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:35:33.942 2009  to  Mon Jan 19 19:35:33.971 2009   (  0.03) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  14  SHUTDOWN  PSF        command.shutdown                                              Mon Jan 19 19:35:58.121 2009  to  Mon Jan 19 19:35:58.121 2009   (  0.00) secs
                    right PSF shutdown started

  15  SHUTDOWN  PSF        command.shutdown                                              Mon Jan 19 19:35:58.607 2009  to  Mon Jan 19 19:35:58.607 2009   (  0.00) secs
                    right PSF shutdown complete

  16  SHUTDOWN  PSF        shutdown                                                      Mon Jan 19 19:35:58.629 2009  to  Mon Jan 19 19:35:58.629 2009   (  0.00) secs
                    right PSF subsystem shut down

  17  STARTUP   PSF        startup                                                       Mon Jan 19 19:36:02.744 2009  to  Mon Jan 19 19:36:02.744 2009   (  0.00) secs
                    right PSF subsystem started, version 4.27

  18  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:36:12.432 2009  to  Mon Jan 19 19:36:12.481 2009   (  0.05) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  19  STARTUP   PSF        startup                                                       Mon Jan 19 19:36:27.377 2009  to  Mon Jan 19 19:36:27.377 2009   (  0.00) secs
                    right PSF subsystem started, version 4.27

  20  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jan 19 19:38:55.223 2009  to  Mon Jan 19 19:39:29.352 2009   ( 34.13) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  21  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:39:21.224 2009  to  Mon Jan 19 19:39:29.326 2009   (  8.10) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  22  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:40:39.451 2009  to  Mon Jan 19 19:40:39.727 2009   (  0.28) secs
                    right PSF SetInstrumentOffsets failed

  23  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:40:39.504 2009  to  Mon Jan 19 19:40:39.670 2009   (  0.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  24  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:40:39.557 2009  to  Mon Jan 19 19:40:39.615 2009   (  0.06) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  25  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:44:01.902 2009  to  Mon Jan 19 19:44:02.180 2009   (  0.28) secs
                    right PSF SetInstrumentOffsets failed

  26  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:44:02.008 2009  to  Mon Jan 19 19:44:02.070 2009   (  0.06) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  27  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:44:01.956 2009  to  Mon Jan 19 19:44:02.126 2009   (  0.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  28  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:48:35.303 2009  to  Mon Jan 19 19:48:35.350 2009   (  0.05) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.025 2009  to  Mon Jan 19 20:04:16.025 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.7911358e-03 3.0584335e-03 -9.7298622e-03 7.8508377e-02 -2.2705078e-02 1.2616861e-01

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.257 2009  to  Mon Jan 19 20:04:16.257 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.7911358e-03 3.0584335e-03 -9.7298622e-03 7.8508377e-02 -2.2705078e-02 1.2616861e-01

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.500 2009  to  Mon Jan 19 20:04:16.500 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.733 2009  to  Mon Jan 19 20:04:16.733 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.969 2009  to  Mon Jan 19 20:04:16.969 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.224 2009  to  Mon Jan 19 20:04:17.224 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 3.9607167e-02 1.5920162e-02 -4.6644688e-02 -8.3507538e-02 -4.1903305e-01 3.8066632e-01

  35  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.453 2009  to  Mon Jan 19 20:04:17.453 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 5.1034451e-02 2.1693230e-02 -6.7352474e-02 4.1961670e-03 -5.8298492e-01 3.7969238e-01

  36  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.696 2009  to  Mon Jan 19 20:04:17.696 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 5.1034451e-02 2.1693230e-02 -6.7352474e-02 4.1961670e-03 -5.8298492e-01 3.7969238e-01

  37  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.933 2009  to  Mon Jan 19 20:04:17.933 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 6.0786009e-02 2.8680325e-02 -8.9616895e-02 2.5839233e-01 -8.8972855e-01 4.2047459e-01

  38  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.204 2009  to  Mon Jan 19 20:04:18.204 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 6.0786009e-02 2.8680325e-02 -8.9616895e-02 2.5839233e-01 -8.8972855e-01 4.2047459e-01

  39  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.439 2009  to  Mon Jan 19 20:04:18.439 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.0999980e-02 3.4157038e-02 -1.1014241e-01 4.3077087e-01 -1.1322250e+00 3.6515898e-01

  40  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.674 2009  to  Mon Jan 19 20:04:18.674 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.0999980e-02 3.4157038e-02 -1.1014241e-01 4.3077087e-01 -1.1322250e+00 3.6515898e-01

  41  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.911 2009  to  Mon Jan 19 20:04:18.911 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  42  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.145 2009  to  Mon Jan 19 20:04:19.145 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  43  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.376 2009  to  Mon Jan 19 20:04:19.376 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  44  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.606 2009  to  Mon Jan 19 20:04:19.606 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 8.9577079e-02 4.7206402e-02 -1.5199256e-01 8.2361412e-01 -1.7012711e+00 3.5946453e-01

  45  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.836 2009  to  Mon Jan 19 20:04:19.836 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 8.9577079e-02 4.7206402e-02 -1.5199256e-01 8.2361412e-01 -1.7012711e+00 3.5946453e-01

  46  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:20.090 2009  to  Mon Jan 19 20:04:20.090 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.9805832e-02 5.4508448e-02 -1.7310441e-01 1.0370655e+00 -1.9407043e+00 3.3596039e-01

  47  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:05:21.996 2009  to  Mon Jan 19 20:05:22.125 2009   (  0.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:06:06.617 2009  to  Mon Jan 19 20:06:06.754 2009   (  0.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

  49  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:12:14.686 2009  to  Mon Jan 19 20:13:06.915 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 20:13:06.810 2009  to  Mon Jan 19 20:13:07.121 2009   (  0.31) secs
                    left PSF SetInstrumentOffsets failed

  51  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 20:13:06.862 2009  to  Mon Jan 19 20:13:07.091 2009   (  0.23) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  52  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:13:06.915 2009  to  Mon Jan 19 20:13:07.043 2009   (  0.13) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  53  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:13:18.909 2009  to  Mon Jan 19 20:13:18.909 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  54  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:42.244 2009  to  Mon Jan 19 23:02:53.272 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  55  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:42.251 2009  to  Mon Jan 19 23:02:53.307 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  56  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 23:02:53.164 2009  to  Mon Jan 19 23:02:53.567 2009   (  0.40) secs
                    left PSF SetInstrumentOffsets failed

  57  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 23:02:53.202 2009  to  Mon Jan 19 23:02:53.700 2009   (  0.50) secs
                    right PSF SetInstrumentOffsets failed

  58  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:53.272 2009  to  Mon Jan 19 23:02:53.454 2009   (  0.18) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  59  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 23:02:53.219 2009  to  Mon Jan 19 23:02:53.511 2009   (  0.29) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  60  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 23:02:53.255 2009  to  Mon Jan 19 23:02:53.542 2009   (  0.29) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:53.307 2009  to  Mon Jan 19 23:02:53.485 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:55.416 2009  to  Mon Jan 19 23:02:55.416 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  63  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:03:00.450 2009  to  Mon Jan 19 23:03:00.450 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  64  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:35:43.116 2009  to  Mon Jan 19 23:36:24.158 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  65  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:35:43.120 2009  to  Mon Jan 19 23:36:24.163 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  66  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:24.158 2009  to  Mon Jan 19 23:36:24.313 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  67  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:24.163 2009  to  Mon Jan 19 23:36:24.337 2009   (  0.17) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:28.333 2009  to  Mon Jan 19 23:36:28.333 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.badCommandReceived                       Mon Jan 19 17:13:55.284 2009  to  Mon Jan 19 17:13:55.284 2009   (  0.00) secs
                    Received a powerSA command with BAD arguments = left pf

   2  FAILED    MCS.MCSPU  MCSPU.OpticalSupport.badCommandReceived                       Mon Jan 19 17:29:31.636 2009  to  Mon Jan 19 17:29:31.636 2009   (  0.00) secs
                    Received a powerSA command with BAD arguments = left right

   3  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.626 2009  to  Mon Jan 19 17:37:12.626 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.626 2009  to  Mon Jan 19 17:37:12.626 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.627 2009  to  Mon Jan 19 17:37:12.627 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.627 2009  to  Mon Jan 19 17:37:12.627 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.628 2009  to  Mon Jan 19 17:37:12.628 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.629 2009  to  Mon Jan 19 17:37:12.629 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.629 2009  to  Mon Jan 19 17:37:12.629 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:37:12.630 2009  to  Mon Jan 19 17:37:12.630 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    PMC        actuator.forceMonitor1.panic                                  Mon Jan 19 17:39:29.645 2009  to  Mon Jan 19 17:39:29.645 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 1 PANIC! -171.3 lbs, limit is 0.0

  12  FAILED    PMC        actuator.forceMonitor2.panic                                  Mon Jan 19 17:39:29.695 2009  to  Mon Jan 19 17:39:29.695 2009   (  0.00) secs
                    right PMC Actuator 430 force monitor 2 PANIC! 447.8 lbs, limit is 0.0

  13  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Mon Jan 19 17:47:11.965 2009  to  Mon Jan 19 17:47:11.965 2009   (  0.00) secs
                    

  14  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.601 2009  to  Mon Jan 19 17:50:44.601 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.602 2009  to  Mon Jan 19 17:50:44.602 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.603 2009  to  Mon Jan 19 17:50:44.603 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.603 2009  to  Mon Jan 19 17:50:44.603 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.604 2009  to  Mon Jan 19 17:50:44.604 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.604 2009  to  Mon Jan 19 17:50:44.604 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.605 2009  to  Mon Jan 19 17:50:44.605 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Mon Jan 19 17:50:44.606 2009  to  Mon Jan 19 17:50:44.606 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  22  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Mon Jan 19 17:50:54.019 2009  to  Mon Jan 19 17:50:54.019 2009   (  0.00) secs
                    

  23  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 19 18:22:28.322 2009  to  Mon Jan 19 18:22:28.322 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  24  FAILED    PMC        thermal.badReceive                                            Mon Jan 19 18:22:28.378 2009  to  Mon Jan 19 18:22:28.378 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  25  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 19 18:22:28.351 2009  to  Mon Jan 19 18:22:28.351 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  26  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 18:48:43.875 2009  to  Mon Jan 19 18:51:37.126 2009   (173.25) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485107549768518e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                    IIF Preset command failed for both LBC mode TRACK from IIF

  27  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 18:50:05.775 2009  to  Mon Jan 19 18:50:05.834 2009   (  0.06) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  28  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:37.008 2009  to  Mon Jan 19 19:00:37.008 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

  29  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:39.856 2009  to  Mon Jan 19 19:00:39.856 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.5924397e-04 -1.1770725e-03 3.3580065e-03 -2.0450592e-02 3.7883759e-02 3.3767223e-03

  30  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.079 2009  to  Mon Jan 19 19:00:40.079 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 7.5924397e-04 -1.1770725e-03 3.3580065e-03 -2.0450592e-02 3.7883759e-02 3.3767223e-03

  31  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.717 2009  to  Mon Jan 19 19:00:40.717 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.4970384e-04 -7.9417229e-04 3.1224489e-03 -1.1938095e-02 9.7084045e-03 -9.9670887e-03

  32  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:40.941 2009  to  Mon Jan 19 19:00:40.941 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.4970384e-04 -7.9417229e-04 3.1224489e-03 -1.1938095e-02 9.7084045e-03 -9.9670887e-03

  33  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:43.218 2009  to  Mon Jan 19 19:00:43.218 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

  34  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 19:00:43.442 2009  to  Mon Jan 19 19:00:43.442 2009   (  0.00) secs
                    left PSF primary mirror collimation position error: 5.7917833e-04 -8.8119507e-04 3.1710863e-03 -3.6441803e-02 5.4916382e-02 1.3966322e-02

  35  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:00:46.121 2009  to  Mon Jan 19 19:00:46.484 2009   (  0.36) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  36  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:00:46.186 2009  to  Mon Jan 19 19:00:46.392 2009   (  0.21) secs
                    right PSF SetInstrumentOffsets failed

  37  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:00:46.272 2009  to  Mon Jan 19 19:00:46.313 2009   (  0.04) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  38  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:00:46.240 2009  to  Mon Jan 19 19:00:46.353 2009   (  0.11) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  39  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 19:06:30.938 2009  to  Mon Jan 19 19:06:43.084 2009   ( 12.15) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485108784722222e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: Invalid buffer: RPCERROR
                    IIF Preset command failed for both LBC mode TRACK from IIF

  40  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:06:39.905 2009  to  Mon Jan 19 19:06:39.939 2009   (  0.03) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  41  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:35:33.942 2009  to  Mon Jan 19 19:35:33.971 2009   (  0.03) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  42  SHUTDOWN  PSF        command.shutdown                                              Mon Jan 19 19:35:58.121 2009  to  Mon Jan 19 19:35:58.121 2009   (  0.00) secs
                    right PSF shutdown started

  43  SHUTDOWN  PSF        command.shutdown                                              Mon Jan 19 19:35:58.607 2009  to  Mon Jan 19 19:35:58.607 2009   (  0.00) secs
                    right PSF shutdown complete

  44  SHUTDOWN  PSF        shutdown                                                      Mon Jan 19 19:35:58.629 2009  to  Mon Jan 19 19:35:58.629 2009   (  0.00) secs
                    right PSF subsystem shut down

  45  STARTUP   PSF        startup                                                       Mon Jan 19 19:36:02.744 2009  to  Mon Jan 19 19:36:02.744 2009   (  0.00) secs
                    right PSF subsystem started, version 4.27

  46  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:36:12.432 2009  to  Mon Jan 19 19:36:12.481 2009   (  0.05) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  47  STARTUP   PSF        startup                                                       Mon Jan 19 19:36:27.377 2009  to  Mon Jan 19 19:36:27.377 2009   (  0.00) secs
                    right PSF subsystem started, version 4.27

  48  FAILED    PSF        primaryMirror.command.adjustMirror                            Mon Jan 19 19:38:55.223 2009  to  Mon Jan 19 19:39:29.352 2009   ( 34.13) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  49  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:39:21.224 2009  to  Mon Jan 19 19:39:29.326 2009   (  8.10) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  50  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 19:39:21.256 2009  to  Mon Jan 19 19:39:29.293 2009   (  8.04) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  51  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:40:39.387 2009  to  Mon Jan 19 19:40:39.834 2009   (  0.45) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  52  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:40:39.451 2009  to  Mon Jan 19 19:40:39.727 2009   (  0.28) secs
                    right PSF SetInstrumentOffsets failed

  53  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:40:39.504 2009  to  Mon Jan 19 19:40:39.670 2009   (  0.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:40:39.557 2009  to  Mon Jan 19 19:40:39.615 2009   (  0.06) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  55  FAILED    IIF        command.moveFocus                                             Mon Jan 19 19:44:01.865 2009  to  Mon Jan 19 19:44:02.304 2009   (  0.44) secs
                    IIF MoveFocus command started for left LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for right LBC: Invalid buffer: RPCERROR
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  56  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 19:44:01.902 2009  to  Mon Jan 19 19:44:02.180 2009   (  0.28) secs
                    right PSF SetInstrumentOffsets failed

  57  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:44:02.008 2009  to  Mon Jan 19 19:44:02.070 2009   (  0.06) secs
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  58  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 19:44:01.956 2009  to  Mon Jan 19 19:44:02.126 2009   (  0.17) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  59  FAILED    PMC        actuator.telemetryError                                       Mon Jan 19 19:47:26.271 2009  to  Mon Jan 19 19:47:26.271 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  60  STARTUP   PMC        startup                                                       Mon Jan 19 19:47:29.631 2009  to  Mon Jan 19 19:47:29.631 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

  61  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 19:48:35.303 2009  to  Mon Jan 19 19:48:35.350 2009   (  0.05) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Invalid buffer: RPCERROR

  62  SHUTDOWN  OSS        shutdown                                                      Mon Jan 19 19:57:46.229 2009  to  Mon Jan 19 19:57:46.229 2009   (  0.00) secs
                    The oss was shut down.

  63  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.717 2009  to  Mon Jan 19 19:57:51.717 2009   (  0.00) secs
                    right PMC PMC closing network connection

  64  SHUTDOWN  PMC        shutdown                                                      Mon Jan 19 19:57:51.693 2009  to  Mon Jan 19 19:57:51.693 2009   (  0.00) secs
                    right PMC subsystem shut down

  65  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.756 2009  to  Mon Jan 19 19:57:51.756 2009   (  0.00) secs
                    right PMC PMCLogger closing network connection

  66  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.775 2009  to  Mon Jan 19 19:57:51.775 2009   (  0.00) secs
                    right PMC Async closing network connection

  67  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.831 2009  to  Mon Jan 19 19:57:51.831 2009   (  0.00) secs
                    right PMC ServoLoop closing network connection

  68  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.850 2009  to  Mon Jan 19 19:57:51.850 2009   (  0.00) secs
                    right PMC Mount closing network connection

  69  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.908 2009  to  Mon Jan 19 19:57:51.908 2009   (  0.00) secs
                    right PMC Mirror closing network connection

  70  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.950 2009  to  Mon Jan 19 19:57:51.950 2009   (  0.00) secs
                    right PMC Hardpoint closing network connection

  71  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:51.992 2009  to  Mon Jan 19 19:57:51.992 2009   (  0.00) secs
                    right PMC Motor closing network connection

  72  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:52.046 2009  to  Mon Jan 19 19:57:52.046 2009   (  0.00) secs
                    right PMC AirPressure closing network connection

  73  FAILED    PMC        VxInterface.close                                             Mon Jan 19 19:57:52.073 2009  to  Mon Jan 19 19:57:52.073 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  74  FAILED    PMC        actuator.telemetryError                                       Mon Jan 19 19:58:15.313 2009  to  Mon Jan 19 19:58:15.313 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  75  STARTUP   PMC        startup                                                       Mon Jan 19 19:58:18.533 2009  to  Mon Jan 19 19:58:18.533 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

  76  STARTUP   OSS        startup                                                       Mon Jan 19 19:58:24.358 2009  to  Mon Jan 19 19:58:24.358 2009   (  0.00) secs
                    The oss was started.

  77  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.025 2009  to  Mon Jan 19 20:04:16.025 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.7911358e-03 3.0584335e-03 -9.7298622e-03 7.8508377e-02 -2.2705078e-02 1.2616861e-01

  78  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.257 2009  to  Mon Jan 19 20:04:16.257 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.7911358e-03 3.0584335e-03 -9.7298622e-03 7.8508377e-02 -2.2705078e-02 1.2616861e-01

  79  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.500 2009  to  Mon Jan 19 20:04:16.500 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  80  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.733 2009  to  Mon Jan 19 20:04:16.733 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  81  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:16.969 2009  to  Mon Jan 19 20:04:16.969 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 2.5480509e-02 9.9515915e-03 -2.8190315e-02 7.6637268e-03 -1.9831085e-01 2.5387228e-01

  82  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.224 2009  to  Mon Jan 19 20:04:17.224 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 3.9607167e-02 1.5920162e-02 -4.6644688e-02 -8.3507538e-02 -4.1903305e-01 3.8066632e-01

  83  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.453 2009  to  Mon Jan 19 20:04:17.453 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 5.1034451e-02 2.1693230e-02 -6.7352474e-02 4.1961670e-03 -5.8298492e-01 3.7969238e-01

  84  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.696 2009  to  Mon Jan 19 20:04:17.696 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 5.1034451e-02 2.1693230e-02 -6.7352474e-02 4.1961670e-03 -5.8298492e-01 3.7969238e-01

  85  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:17.933 2009  to  Mon Jan 19 20:04:17.933 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 6.0786009e-02 2.8680325e-02 -8.9616895e-02 2.5839233e-01 -8.8972855e-01 4.2047459e-01

  86  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.204 2009  to  Mon Jan 19 20:04:18.204 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 6.0786009e-02 2.8680325e-02 -8.9616895e-02 2.5839233e-01 -8.8972855e-01 4.2047459e-01

  87  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.439 2009  to  Mon Jan 19 20:04:18.439 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.0999980e-02 3.4157038e-02 -1.1014241e-01 4.3077087e-01 -1.1322250e+00 3.6515898e-01

  88  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.674 2009  to  Mon Jan 19 20:04:18.674 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.0999980e-02 3.4157038e-02 -1.1014241e-01 4.3077087e-01 -1.1322250e+00 3.6515898e-01

  89  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:18.911 2009  to  Mon Jan 19 20:04:18.911 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  90  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.145 2009  to  Mon Jan 19 20:04:19.145 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  91  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.376 2009  to  Mon Jan 19 20:04:19.376 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 7.9848170e-02 4.0215254e-02 -1.3086772e-01 5.9397125e-01 -1.4341927e+00 3.4071708e-01

  92  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.606 2009  to  Mon Jan 19 20:04:19.606 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 8.9577079e-02 4.7206402e-02 -1.5199256e-01 8.2361412e-01 -1.7012711e+00 3.5946453e-01

  93  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:19.836 2009  to  Mon Jan 19 20:04:19.836 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 8.9577079e-02 4.7206402e-02 -1.5199256e-01 8.2361412e-01 -1.7012711e+00 3.5946453e-01

  94  FAILED    PSF        primaryMirror.positionError                                   Mon Jan 19 20:04:20.090 2009  to  Mon Jan 19 20:04:20.090 2009   (  0.00) secs
                    right PSF primary mirror collimation position error: 9.9805832e-02 5.4508448e-02 -1.7310441e-01 1.0370655e+00 -1.9407043e+00 3.3596039e-01

  95  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 20:04:54.233 2009  to  Mon Jan 19 20:05:43.266 2009   ( 49.03) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485112840277778e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset command failed for both LBC mode TRACK from IIF

  96  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:05:21.996 2009  to  Mon Jan 19 20:05:22.125 2009   (  0.13) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  97  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:05:22.056 2009  to  Mon Jan 19 20:05:22.093 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  98  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 20:05:58.905 2009  to  Mon Jan 19 20:06:10.903 2009   ( 12.00) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485112914351852e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state
                    IIF Preset command failed for both LBC mode TRACK from IIF

  99  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:06:06.617 2009  to  Mon Jan 19 20:06:06.754 2009   (  0.14) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 100  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:06:06.684 2009  to  Mon Jan 19 20:06:06.720 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Wrong mirror state

 101  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:12:14.686 2009  to  Mon Jan 19 20:13:06.915 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 102  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:12:14.727 2009  to  Mon Jan 19 20:13:06.976 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 103  FAILED    IIF        command.moveFocus                                             Mon Jan 19 20:13:06.767 2009  to  Mon Jan 19 20:13:07.226 2009   (  0.46) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485113409722222e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 104  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 20:13:06.810 2009  to  Mon Jan 19 20:13:07.121 2009   (  0.31) secs
                    left PSF SetInstrumentOffsets failed

 105  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 20:13:06.862 2009  to  Mon Jan 19 20:13:07.091 2009   (  0.23) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 106  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:13:06.915 2009  to  Mon Jan 19 20:13:07.043 2009   (  0.13) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 107  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:13:06.976 2009  to  Mon Jan 19 20:13:07.005 2009   (  0.03) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 108  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 20:13:18.874 2009  to  Mon Jan 19 20:13:18.874 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 109  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 20:13:18.909 2009  to  Mon Jan 19 20:13:18.909 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 110  FAILED    PMC        VxInterface.close                                             Mon Jan 19 21:44:21.683 2009  to  Mon Jan 19 21:44:21.683 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 111  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 21:44:21.662 2009  to  Mon Jan 19 21:44:21.662 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 112  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 21:54:04.228 2009  to  Mon Jan 19 21:55:45.709 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 113  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 21:54:04.499 2009  to  Mon Jan 19 21:54:04.499 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 114  FAILED    PMC        VxInterface.packetReadError                                   Mon Jan 19 22:30:36.359 2009  to  Mon Jan 19 22:30:36.359 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 115  FAILED    PMC        VxInterface.selectTimeout                                     Mon Jan 19 22:30:36.340 2009  to  Mon Jan 19 22:30:36.340 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 116  FAILED    PMC        thermal.badReceive                                            Mon Jan 19 22:30:36.377 2009  to  Mon Jan 19 22:30:36.377 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 117  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 22:45:57.459 2009  to  Mon Jan 19 22:45:57.459 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 118  FAILED    PMC        VxInterface.close                                             Mon Jan 19 22:45:57.481 2009  to  Mon Jan 19 22:45:57.481 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 119  FAILED    PMC        VxInterface.close                                             Mon Jan 19 22:50:54.836 2009  to  Mon Jan 19 22:50:54.836 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 120  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 22:50:54.817 2009  to  Mon Jan 19 22:50:54.817 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 121  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 22:55:11.556 2009  to  Mon Jan 19 23:02:16.835 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 122  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 22:55:11.826 2009  to  Mon Jan 19 22:55:11.826 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 123  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:02:16.835 2009  to  Mon Jan 19 23:10:53.660 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 124  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:02:17.148 2009  to  Mon Jan 19 23:02:17.148 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 125  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:42.244 2009  to  Mon Jan 19 23:02:53.272 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 126  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:42.251 2009  to  Mon Jan 19 23:02:53.307 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 127  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:42.304 2009  to  Mon Jan 19 23:02:53.335 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 128  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:42.315 2009  to  Mon Jan 19 23:02:53.368 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 129  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 23:02:53.164 2009  to  Mon Jan 19 23:02:53.567 2009   (  0.40) secs
                    left PSF SetInstrumentOffsets failed

 130  FAILED    IIF        command.moveFocus                                             Mon Jan 19 23:02:53.129 2009  to  Mon Jan 19 23:02:53.776 2009   (  0.65) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus alert for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus alert for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus alert for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 131  FAILED    IIF        command.moveFocus                                             Mon Jan 19 23:02:53.140 2009  to  Mon Jan 19 23:02:53.859 2009   (  0.72) secs
                    IIF MoveFocus alert for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 132  FAILED    PSF        command.setInstrumentOffsets                                  Mon Jan 19 23:02:53.202 2009  to  Mon Jan 19 23:02:53.700 2009   (  0.50) secs
                    right PSF SetInstrumentOffsets failed

 133  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:53.272 2009  to  Mon Jan 19 23:02:53.454 2009   (  0.18) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 134  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 23:02:53.219 2009  to  Mon Jan 19 23:02:53.511 2009   (  0.29) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 135  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Mon Jan 19 23:02:53.255 2009  to  Mon Jan 19 23:02:53.542 2009   (  0.29) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 136  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:53.335 2009  to  Mon Jan 19 23:02:53.390 2009   (  0.06) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 137  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:53.307 2009  to  Mon Jan 19 23:02:53.485 2009   (  0.18) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 138  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:53.368 2009  to  Mon Jan 19 23:02:53.420 2009   (  0.05) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 139  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:02:55.382 2009  to  Mon Jan 19 23:02:55.382 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 140  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:02:55.416 2009  to  Mon Jan 19 23:02:55.416 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 141  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:03:00.403 2009  to  Mon Jan 19 23:03:00.403 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 142  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:03:00.450 2009  to  Mon Jan 19 23:03:00.450 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 143  FAILED    PMC        VxInterface.close                                             Mon Jan 19 23:10:17.399 2009  to  Mon Jan 19 23:10:17.399 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 144  FAILED    PMC        VxInterface.lengthError                                       Mon Jan 19 23:10:17.380 2009  to  Mon Jan 19 23:10:17.380 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 145  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:24:43.790 2009  to  Mon Jan 19 23:34:59.446 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 146  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:24:44.120 2009  to  Mon Jan 19 23:24:44.120 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 147  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jan 19 23:34:59.332 2009  to  Mon Jan 19 23:36:08.422 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Preset command started for both LBC mode TRACK from IIF

 148  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:35:43.167 2009  to  Mon Jan 19 23:36:24.220 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 149  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:35:43.183 2009  to  Mon Jan 19 23:36:24.234 2009   (  0.00) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 150  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:35:43.116 2009  to  Mon Jan 19 23:36:24.158 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 151  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:35:43.120 2009  to  Mon Jan 19 23:36:24.163 2009   (  0.00) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 152  FAILED    IIF        command.preset.(TRACK)                                        Mon Jan 19 23:36:08.422 2009  to  Mon Jan 19 23:36:24.471 2009   ( 16.05) secs
                    IIF GetTrajectory command started for both LBC, start time 5.485127509259259e+04, time 3.550000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset alert for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset alert for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset command failed for both LBC mode TRACK from IIF

 153  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:24.220 2009  to  Mon Jan 19 23:36:24.256 2009   (  0.04) secs
                    Started event but no Complete event
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 154  FAILED    PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:24.234 2009  to  Mon Jan 19 23:36:24.278 2009   (  0.04) secs
                    right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 155  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:24.158 2009  to  Mon Jan 19 23:36:24.313 2009   (  0.15) secs
                    Started event but no Complete event
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 156  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:24.163 2009  to  Mon Jan 19 23:36:24.337 2009   (  0.17) secs
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 157  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:28.300 2009  to  Mon Jan 19 23:36:28.300 2009   (  0.00) secs
                    Complete event but no Started event
                    right PMC Mirror GoToPositionAbs Command Complete

 158  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Mon Jan 19 23:36:28.333 2009  to  Mon Jan 19 23:36:28.333 2009   (  0.00) secs
                    Complete event but no Started event
                    right PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 159  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Mon Jan 19 23:36:29.282 2009  to  Mon Jan 19 23:36:29.282 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 160  SEQERROR  IIF        command.preset.(TRACK)                                        Mon Jan 19 23:36:31.400 2009  to  Mon Jan 19 23:36:31.400 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Preset command complete for both LBC mode TRACK from IIF

 161  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:57:58.606 2009  to  Tue Jan 20 00:03:32.682 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 162  SEQERROR  PCS        telescope.command.startTracking                               Mon Jan 19 23:57:58.913 2009  to  Mon Jan 19 23:57:58.913 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 163  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:44:53.099 2009  to  Tue Jan 20 00:53:22.971 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 164  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:44:53.372 2009  to  Tue Jan 20 00:44:53.372 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 165  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:53:22.971 2009  to  Tue Jan 20 01:03:40.810 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 166  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 00:53:23.241 2009  to  Tue Jan 20 00:53:23.241 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 167  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:03:40.810 2009  to  Tue Jan 20 01:05:03.278 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 168  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:03:41.083 2009  to  Tue Jan 20 01:03:41.083 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 169  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:05:41.606 2009  to  Tue Jan 20 01:05:41.606 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 170  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:05:41.586 2009  to  Tue Jan 20 01:05:41.586 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 171  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:15:45.837 2009  to  Tue Jan 20 01:25:14.195 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 172  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 01:15:46.107 2009  to  Tue Jan 20 01:15:46.107 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 173  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:15:54.294 2009  to  Tue Jan 20 01:15:54.294 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 174  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:15:54.317 2009  to  Tue Jan 20 01:15:54.317 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 175  FAILED    PMC        VxInterface.close                                             Tue Jan 20 01:51:14.243 2009  to  Tue Jan 20 01:51:14.243 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 176  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 01:51:14.219 2009  to  Tue Jan 20 01:51:14.219 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 177  FAILED    ECS        plc.read.failed                                               Tue Jan 20 01:55:18.919 2009  to  Tue Jan 20 01:55:18.919 2009   (  0.00) secs
                    ECS PLC read failed because Could Not Read the Following Tags: :Local:10:I

 178  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component MV_TEMP_SETPNT_LEFT, value 3.5353699e+01, because PLC Read Failed

 179  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component CA_TEMP_SETPNT, value 3.5353699e+01, because PLC Read Failed

 180  FAILED    ECS        plc.writeHS.failed                                            Tue Jan 20 01:55:18.920 2009  to  Tue Jan 20 01:55:18.920 2009   (  0.00) secs
                    ECS PLC write failed for system HostSetpoint, component IC_TEMP_SETPNT_LEFT, value 3.5755402e+01, because PLC Read Failed

 181  FAILED    ECS        instrumentCooling.command.setTemperatureSetPt                 Tue Jan 20 01:55:19.010 2009  to  Tue Jan 20 01:55:19.010 2009   (  0.00) secs
                    Instrument cooling command set temperature set pt failed:temp 2.0863335e+00

 182  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 02:00:38.453 2009  to  Tue Jan 20 02:08:24.566 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 183  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 02:00:38.749 2009  to  Tue Jan 20 02:00:38.749 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 184  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:00:46.906 2009  to  Tue Jan 20 02:00:46.906 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 185  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:00:46.885 2009  to  Tue Jan 20 02:00:46.885 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 186  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:14:11.582 2009  to  Tue Jan 20 02:14:11.582 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 187  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:14:11.563 2009  to  Tue Jan 20 02:14:11.563 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 188  FAILED    PMC        VxInterface.close                                             Tue Jan 20 02:29:12.194 2009  to  Tue Jan 20 02:29:12.194 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 189  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 02:29:12.175 2009  to  Tue Jan 20 02:29:12.175 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 190  FAILED    PMC        VxInterface.close                                             Tue Jan 20 03:49:42.370 2009  to  Tue Jan 20 03:49:42.370 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 191  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 03:49:42.346 2009  to  Tue Jan 20 03:49:42.346 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 192  FAILED    PMC        VxInterface.close                                             Tue Jan 20 03:55:40.263 2009  to  Tue Jan 20 03:55:40.263 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 193  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 03:55:40.241 2009  to  Tue Jan 20 03:55:40.241 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 194  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:07:39.832 2009  to  Tue Jan 20 04:07:39.832 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 195  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:07:39.850 2009  to  Tue Jan 20 04:07:39.850 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 196  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:11:47.355 2009  to  Tue Jan 20 04:11:47.355 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 197  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:11:47.334 2009  to  Tue Jan 20 04:11:47.334 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 198  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 04:34:10.597 2009  to  Tue Jan 20 05:05:00.696 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 199  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 04:34:10.882 2009  to  Tue Jan 20 04:34:10.882 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 200  FAILED    PMC        VxInterface.close                                             Tue Jan 20 04:49:01.228 2009  to  Tue Jan 20 04:49:01.228 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 201  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:49:01.208 2009  to  Tue Jan 20 04:49:01.208 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 202  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 04:57:56.227 2009  to  Tue Jan 20 04:57:56.227 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

 203  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 05:05:00.696 2009  to  Tue Jan 20 05:14:38.962 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 204  SEQERROR  PCS        telescope.command.startTracking                               Tue Jan 20 05:05:00.965 2009  to  Tue Jan 20 05:05:00.965 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 205  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:08:21.132 2009  to  Tue Jan 20 05:08:21.132 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 206  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:58:27.822 2009  to  Tue Jan 20 05:58:27.822 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 207  FAILED    PMC        VxInterface.lengthError                                       Tue Jan 20 05:59:49.910 2009  to  Tue Jan 20 05:59:49.910 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

**********************************************************
    Reporting period ending:   Tue Jan 20 07:50:59.929 2009
********************************************************************************************************