    TCS Software Performance Report
 
    Observing Night:   Jan 2 2009 to Jan 3 2009
 
    Reporting period beginning:   Fri Jan  2 16:55:01.164 2009
    Reporting period ending:      Sat Jan  3 07:52:59.964 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.ELDrive.commandReceived,  priority = 0, 2
      event = MCS.MCSPU.ELDrive.Stowpins.CommandStop,  priority = 0, 2
      event = gcs.command.getCentroid.triggered,  priority = 0, 2
      event = gcs.command.stopGuiding.triggered,  priority = 0, 2
      event = gcs.command.getGuideStar.triggered,  priority = 0, 2
      event = gcs.command.getStatus.triggered,  priority = 0, 2
      event = gcs.command.getAGW.triggered,  priority = 0, 2
      event = gcs.command.isAcquiring.triggered,  priority = 0, 2
      event = gcs.command.isGuiding.triggered,  priority = 0, 2
      event = gcs.command.isWFsensing.triggered,  priority = 0, 2
      event = gcs.command.getGuideRate.triggered,  priority = 0, 2
      event = gcs.command.getGuideCamExposureTime.triggered,  priority = 0, 2
      event = gcs.command.getWFCamExposureTime.triggered,  priority = 0, 2
      event = gcs.command.getFocus.triggered,  priority = 0, 2
      event = gcs.command.getFilter.triggered,  priority = 0, 2
      event = gcs.command.getAGWStatus.triggered,  priority = 0, 2
      event = gcs.command.getPositionAGW.triggered,  priority = 0, 2
      event = gcs.command.startAcquiring.triggered,  priority = 0, 2
      event = gcs.command.getAcquireImage.triggered,  priority = 0, 2
      event = gcs.command.setGuideCamExposureTime.triggered,  priority = 0, 2
      event = pcs.telescope.command.listPMTerms.started,  priority = 0, 2
      event = pcs.telescope.command.listPMTerms.complete,  priority = 0, 2
      event = pcs.telescope.command.setPMTerm.started,  priority = 0, 2
      event = pcs.telescope.command.setPMTerm.complete,  priority = 0, 2
      event = gcs.command.stopAcquiring.triggered,  priority = 0, 2
      event = gcs.command.autoAcquireGuidestar.triggered,  priority = 0, 2
      event = gcs.command.getGuideImage.triggered,  priority = 0, 2
      event = gcs.command.startWFsensing.triggered,  priority = 0, 2
      event = gcs.command.getWFImage.triggered,  priority = 0, 2
      event = gcs.command.stopWFsensing.triggered,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                       stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     IIFCommand.authorize . . . . . . . . . . . . . . . . . . . . .    0.11    4.19    4.10    4.27     0.0 %          2                     2           
                                                                                                   

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest

   1  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Jan  2 18:18:42.563 2009  to  Fri Jan  2 18:18:46.668 2009   (  4.10) secs
                    IIF TCS authorize command started for right LBC at prime focus
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF secondary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF tertiary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF SetNewInstrument complete for instrument LUCIFER, focal station bentGregorianFront
                    IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

   2  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Jan  2 18:18:42.666 2009  to  Fri Jan  2 18:18:46.934 2009   (  4.27) secs
                    IIF TCS authorize failure for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                    IIF TCS authorize failure for right LBC at prime focus: right PSF SetNewInstrument complete for instrument LBC, focal station prime
                    IIF TCS authorize command failed for right LBC at prime focus
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.preset.(ACQUIRE) . . . . . . . . . . . . . . . . . . .   84.50  113.92    5.09  203.64    28.6 %          7          1          5          1
                                                                       0.00  145.04  145.04  145.04
     command.preset.(ACTIVE). . . . . . . . . . . . . . . . . . . .   30.00  120.93   97.46  154.74    66.7 %          3          2          1           
                                                                      31.21  132.67  110.60  154.74

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             2

IIF Events of Interest

   1  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:49:28.893 2009  to  Fri Jan  2 19:52:30.391 2009   (181.50) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.443063, 0.279351, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

   2  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:53:42.427 2009  to  Fri Jan  2 19:55:56.149 2009   (133.72) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: Invalid buffer: RPCERROR
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

   3  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:56:55.987 2009  to  Fri Jan  2 20:00:19.630 2009   (203.64) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.236512, 0.471056, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

   4  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 20:04:46.422 2009  to  Fri Jan  2 20:04:51.515 2009   (  5.09) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.230155, 0.468411, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

   5  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 20:07:10.829 2009  to  Fri Jan  2 20:07:25.352 2009   ( 14.52) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: Axes had not been homed, yet
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.226937, 0.46704, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

   6  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Jan  2 22:22:54.447 2009  to  Fri Jan  2 22:24:31.907 2009   ( 97.46) secs
                    IIF Preset command started for left LUCIFER mode ACTIVE from IIF
                    IIF Preset failure for left LUCIFER mode ACTIVE: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset failure for left LUCIFER mode ACTIVE: couldn't find a star in any GS location.
                    IIF Preset command failed for left LUCIFER mode ACTIVE from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4636                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  9272                      
                                                                                                   
     mirrorVent.blower.command.resetAlarm . . . . . . . . . . . . .                                   100.0 %                     9                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                    12                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   
     mirrorVent.damper.command.resetAlarm . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .     283                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.autoAcquireGuidestar . . . . . . . . . . . . . . . . .    1.93   22.74   21.38   24.11    66.7 %          3          2                      
                                                                       1.93   22.74   21.38   24.11
     command.autoAcquireGuidestar.starDetection . . . . . . . . . .    5.80    6.83    3.29   13.53    66.7 %          3          2          1           
                                                                       0.28    3.48    3.29    3.68
     command.autoAcquireGuidestar.starDetection.clusteredSearch . .    0.00   10.10   10.10   10.10   100.0 %          1          1                      
                                                                       0.00   10.10   10.10   10.10
     command.getAcquireImage. . . . . . . . . . . . . . . . . . . .                                   100.0 %        502                                 
                                                                                                   
     command.getAGW . . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getAGWStatus . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getCentroid. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %        390                                 
                                                                                                   
     command.getFilter. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getFocus . . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getGuideImage. . . . . . . . . . . . . . . . . . . . .                                   100.0 %        132                                 
                                                                                                   
     command.getGuideRate . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getGuideStar . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getPositionAGW . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getStatus. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getWFCamExposureTime . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.getWFImage . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.isAcquiring. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.isGuiding. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         10                                 
                                                                                                   
     command.isWFsensing. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %          5                                 
                                                                                                   
     command.setGuideCamExposureTime. . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.startAcquiring . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.startWFsensing . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.stopAcquiring. . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         14                                 
                                                                                                   
     command.stopWFsensing. . . . . . . . . . . . . . . . . . . . .                                   100.0 %          2                                 
                                                                                                   
     interface.agw.setProbePosition . . . . . . . . . . . . . . . .    8.39    7.31    0.00   24.95    55.6 %          9          5          4           
                                                                       6.68   13.16    8.83   24.95
     interface.azcam.guider.readout . . . . . . . . . . . . . . . .    0.86    4.78    3.13    6.97    97.1 %         69         67                        interrupted =     2
                                                                       0.86    4.78    3.13    6.97
     interface.azcam.wfsc.readout . . . . . . . . . . . . . . . . .    0.07   32.38   32.30   32.46    75.0 %          8          6                        interrupted =     2
                                                                       0.07   32.38   32.30   32.46
     interface.pcs.adjustGSCoordinates. . . . . . . . . . . . . . .    0.08    0.08    0.04    0.29   100.0 %          9          9                      
                                                                       0.08    0.08    0.04    0.29
     interface.pcs.applyGuideCorrection . . . . . . . . . . . . . .    0.06    0.24    0.10    0.44   100.0 %         64         64                      
                                                                       0.06    0.24    0.10    0.44
     interface.pcs.updateGuideOrigin. . . . . . . . . . . . . . . .    0.87    2.93    2.32    3.55   100.0 %          2          2                      
                                                                       0.87    2.93    2.32    3.55
     interface.psf.setZernikes. . . . . . . . . . . . . . . . . . .    2.57   14.63   11.97   18.89   100.0 %          6          6                      
                                                                       2.57   14.63   11.97   18.89
     wfsthread.calculation. . . . . . . . . . . . . . . . . . . . .    0.33    8.21    7.78    8.62   100.0 %          6          6                      
                                                                       0.33    8.21    7.78    8.62

GCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guidethread.started. . . . . . . . . . . . . . . . . . . . . .       2                      
     wfsthread.started. . . . . . . . . . . . . . . . . . . . . . .       2                      
     guidethread.warning. . . . . . . . . . . . . . . . . . . . . .                             2
     wfsthread.stopped. . . . . . . . . . . . . . . . . . . . . . .       2                      

GCS Events of Interest

   1  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 19:52:30.307 2009  to  Fri Jan  2 19:52:30.307 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 4.430627852829885e-01,2.793512292485157e-01, focus: 3.158714015370968e+01 mm. AGw returned: AGW1: RPC Communication Error

   2  SHUTDOWN  GCS        command.shutdown                                              Fri Jan  2 19:54:54.227 2009  to  Fri Jan  2 19:54:54.227 2009   (  0.00) secs
                    left GCS ShutDown Command Started

   3  SHUTDOWN  GCS        command.shutdown                                              Fri Jan  2 19:55:46.580 2009  to  Fri Jan  2 19:55:46.580 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

   4  STARTUP   GCS        startup                                                       Fri Jan  2 19:56:41.981 2009  to  Fri Jan  2 19:56:41.981 2009   (  0.00) secs
                    left GCS subsystem started

   5  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:00:19.556 2009  to  Fri Jan  2 20:00:19.556 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.365118312569743e-01,4.710558971946952e-01, focus: 3.158713509430014e+01 mm. AGw returned: AGW1: RPC Communication Error

   6  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:04:51.395 2009  to  Fri Jan  2 20:04:51.395 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.301548300535630e-01,4.684110618474666e-01, focus: 3.158714300699662e+01 mm. AGw returned: AGW1: RPC Communication Error

   7  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:07:25.272 2009  to  Fri Jan  2 20:07:25.272 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.269368176978064e-01,4.670396767354393e-01, focus: 3.158714702425744e+01 mm. AGw returned: AGW1: Axes had not been homed, yet

   8  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Jan  2 22:24:18.279 2009  to  Fri Jan  2 22:24:31.809 2009   ( 13.53) secs
                    couldn't find a star in any GS location.
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .      22                      
     unsubscribe. . . . . . . . . . . . . . . . . . . . . . . . . .      18                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     MCSPU.Main.schedulingChange. . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.init . . . . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .      65                      
     MCSPU.Servo.useRelMEnc . . . . . . . . . . . . . . . . . . . .      90                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .      76                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                           147
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                 19           
     MCSPU.Cabinet.driveCabStateStart . . . . . . . . . . . . . . .       6                      
     MCSPU.Servo.ignoreRelMEnc. . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.modeChange. . . . . . . . . . . . . . .      24                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .      37                      
     MCSPU.Cabinet.cabinetOn. . . . . . . . . . . . . . . . . . . .                  6           
     MCSPU.MCSPU.allObjects . . . . . . . . . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.Stowpins.stateChange . . . . . . . . . . . . . .     112                      
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      53                      
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .      41                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                            39
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            26
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .     137                      
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                            11
 *** MCSPU.SwingArm.lockoutNotZenith. . . . . . . . . . . . . . . .                 56           
     MCSPU.Side.stateChange . . . . . . . . . . . . . . . . . . . .      27                      
     MCSPU.ELDrive.Stowpins.commandStop . . . . . . . . . . . . . .      15                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .      14                      
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .      15                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .      10                      
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .      28                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .      50                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .      48                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .      24                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       6                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       7                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .      25                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.stowpinCommandRejected . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.Stowpins.queuedCommand . . . . . . . . . . . . .      25                      
     MCSPU.ELDrive.Stowpins.commandReceived . . . . . . . . . . . .       6                      
     MCSPU.ELDrive.commandReceived. . . . . . . . . . . . . . . . .       1                     1
     MCSPU.ELDrive.Stowpins.CommandStop . . . . . . . . . . . . . .       2                     1
     MCSPU.SwingArm.stateChange . . . . . . . . . . . . . . . . . .      21                      
     MCSPU.OpticalSupport.commandActionReceived . . . . . . . . . .       1                      
     MCSPU.Side.doingCommand. . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Side.completedCommand. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.OpticalSupport.commandReceived . . . . . . . . . . . . .       3                      
     MCSPU.SwingArm.startingRetract . . . . . . . . . . . . . . . .       1                      
     MCSPU.SwingArm.commandCompletion . . . . . . . . . . . . . . .       3                      
     MCSPU.SwingArm.startingDeploy. . . . . . . . . . . . . . . . .       2                      
     MCSPU.SwingArm.deployRetractResult . . . . . . . . . . . . . .       2                      
     MCSPU.Cabinet.cabinetOff . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.AZDrive.nullState. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.ELDrive.commandIgnored . . . . . . . . . . . . . . . . .                  1           
     MCSPU.Rotators.reset . . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rPMReset. . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rcReady . . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Rotators.rWaitOpr. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.cWaitOpr. . . . . . . . . . . . . . . . . . . .                             1
     MCSPU.Rotators.cReady. . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.ready . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.polyStop. . . . . . . . . . . . . . . . . . . .                  1           
     MCSPU.RTracker.hold. . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  1           
     MCSPU.RTracker.slewToHold. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Rotators.rSlewToHold . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToHoldDone. . . . . . . . . . . . . . . . .       1                      
     MCSPU.RTracker.slewToTrack . . . . . . . . . . . . . . . . . .     403                      
     MCSPU.Rotators.rSlewToTrack. . . . . . . . . . . . . . . . . .      11                      
     MCSPU.RTracker.fromSlewToTrack . . . . . . . . . . . . . . . .     367                      
     MCSPU.AZDrive.bldgCantFollow . . . . . . . . . . . . . . . . .                  1           
     MCSPU.AZDrive.zeroIntegTry . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.sendingStop . . . . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .               3468           
     MCSPU.ELDrive.Stowpins.retractWhileEngaging. . . . . . . . . .                             1

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 16:59:52.728 2009  to  Fri Jan  2 16:59:52.728 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 16:59:52.736 2009  to  Fri Jan  2 16:59:52.736 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 16:59:52.833 2009  to  Fri Jan  2 16:59:52.833 2009   (  0.00) secs
                    drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.337 2009  to  Fri Jan  2 16:59:53.337 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.337 2009  to  Fri Jan  2 16:59:53.337 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.338 2009  to  Fri Jan  2 16:59:53.338 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.339 2009  to  Fri Jan  2 16:59:53.339 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.341 2009  to  Fri Jan  2 16:59:53.341 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.341 2009  to  Fri Jan  2 16:59:53.341 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.342 2009  to  Fri Jan  2 16:59:53.342 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.343 2009  to  Fri Jan  2 16:59:53.343 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:04:40.171 2009  to  Fri Jan  2 17:04:40.171 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:04:40.180 2009  to  Fri Jan  2 17:04:40.180 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  14  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:04:40.270 2009  to  Fri Jan  2 17:04:40.270 2009   (  0.00) secs
                    drive cabinet has turned on.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.776 2009  to  Fri Jan  2 17:04:40.776 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.776 2009  to  Fri Jan  2 17:04:40.776 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.777 2009  to  Fri Jan  2 17:04:40.777 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.778 2009  to  Fri Jan  2 17:04:40.778 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.779 2009  to  Fri Jan  2 17:04:40.779 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.780 2009  to  Fri Jan  2 17:04:40.780 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.780 2009  to  Fri Jan  2 17:04:40.780 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.781 2009  to  Fri Jan  2 17:04:40.781 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:21:05.514 2009  to  Fri Jan  2 17:21:05.514 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:21:05.520 2009  to  Fri Jan  2 17:21:05.520 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:21:05.614 2009  to  Fri Jan  2 17:21:05.614 2009   (  0.00) secs
                    drive cabinet has turned on.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.122 2009  to  Fri Jan  2 17:21:06.122 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.122 2009  to  Fri Jan  2 17:21:06.122 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.123 2009  to  Fri Jan  2 17:21:06.123 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.124 2009  to  Fri Jan  2 17:21:06.124 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.125 2009  to  Fri Jan  2 17:21:06.125 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.126 2009  to  Fri Jan  2 17:21:06.126 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.126 2009  to  Fri Jan  2 17:21:06.126 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.128 2009  to  Fri Jan  2 17:21:06.128 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan  2 17:25:19.077 2009  to  Fri Jan  2 17:25:19.077 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  35  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.Stowpins.CommandStop                            Fri Jan  2 17:32:56.186 2009  to  Fri Jan  2 17:32:56.186 2009   (  0.00) secs
                    

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:49:59.991 2009  to  Fri Jan  2 17:49:59.991 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  37  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Fri Jan  2 17:50:10.679 2009  to  Fri Jan  2 17:50:10.679 2009   (  0.00) secs
                    

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:53:08.796 2009  to  Fri Jan  2 17:53:08.796 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:53:08.804 2009  to  Fri Jan  2 17:53:08.804 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  40  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:53:08.898 2009  to  Fri Jan  2 17:53:08.898 2009   (  0.00) secs
                    drive cabinet has turned on.

  41  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jan  2 17:56:45.215 2009  to  Fri Jan  2 17:56:45.215 2009   (  0.00) secs
                    Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

  42  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jan  2 17:56:45.216 2009  to  Fri Jan  2 17:56:45.216 2009   (  0.00) secs
                    Axis drive command was ignored because the drive cabinet is turned off.

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:59:07.357 2009  to  Fri Jan  2 17:59:07.357 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:59:07.362 2009  to  Fri Jan  2 17:59:07.362 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 18:02:54.588 2009  to  Fri Jan  2 18:02:54.588 2009   (  0.00) secs
                    drive cabinet has turned on.

  46  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 18:24:17.069 2009  to  Fri Jan  2 18:24:17.069 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  47  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 18:24:17.074 2009  to  Fri Jan  2 18:24:17.074 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  48  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 18:24:17.169 2009  to  Fri Jan  2 18:24:17.169 2009   (  0.00) secs
                    drive cabinet has turned on.

  49  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 19:43:01.729 2009  to  Fri Jan  2 19:43:01.729 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  50  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 19:43:01.734 2009  to  Fri Jan  2 19:43:01.734 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  51  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Jan  2 19:43:02.680 2009  to  Fri Jan  2 19:43:02.680 2009   (  0.00) secs
                    There have been no LFBG track polys for 2.000000000000000e+00 .

  52  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Jan  2 19:43:22.662 2009  to  Fri Jan  2 19:43:22.662 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  53  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sat Jan  3 00:56:28.575 2009  to  Sat Jan  3 00:56:28.575 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

  54  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:26.818 2009  to  Sat Jan  3 04:44:26.818 2009   (  0.00) secs
                    EL bad poly no. 1: BAD: poly EL = -2.198764e-03 rad. Too low.

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:44:27.781 2009  to  Sat Jan  3 04:44:27.781 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:29.868 2009  to  Sat Jan  3 04:44:29.868 2009   (  0.00) secs
                    EL bad poly no. 58: BAD: poly EL = -2.995022e-02 rad. Too low.

  57  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:32.892 2009  to  Sat Jan  3 04:44:32.892 2009   (  0.00) secs
                    EL bad poly no. 104: BAD: poly EL = -2.005203e-01 rad. Too low.

  58  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:46:54.524 2009  to  Sat Jan  3 04:46:54.524 2009   (  0.00) secs
                    EL bad poly no. 107: BAD: poly EL = -1.382628e-03 rad. Too low.

  59  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:46:55.494 2009  to  Sat Jan  3 04:46:55.494 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  60  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:46:57.557 2009  to  Sat Jan  3 04:46:57.557 2009   (  0.00) secs
                    EL bad poly no. 162: BAD: poly EL = -1.438929e-02 rad. Too low.

  61  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:00.611 2009  to  Sat Jan  3 04:47:00.611 2009   (  0.00) secs
                    EL bad poly no. 208: BAD: poly EL = -5.194085e-02 rad. Too low.

  62  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:36.121 2009  to  Sat Jan  3 04:47:36.121 2009   (  0.00) secs
                    EL bad poly no. 211: BAD: poly EL = -7.703964e-03 rad. Too low.

  63  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:47:37.115 2009  to  Sat Jan  3 04:47:37.115 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  64  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:39.126 2009  to  Sat Jan  3 04:47:39.126 2009   (  0.00) secs
                    EL bad poly no. 269: BAD: poly EL = -4.627769e-02 rad. Too low.

  65  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:05.654 2009  to  Sat Jan  3 04:58:05.654 2009   (  0.00) secs
                    EL bad poly no. 288: BAD: poly EL = -7.398658e-07 rad. Too low.

  66  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:58:06.632 2009  to  Sat Jan  3 04:58:06.632 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  67  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:08.723 2009  to  Sat Jan  3 04:58:08.723 2009   (  0.00) secs
                    EL bad poly no. 345: BAD: poly EL = -1.307165e-04 rad. Too low.

  68  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:11.776 2009  to  Sat Jan  3 04:58:11.776 2009   (  0.00) secs
                    EL bad poly no. 391: BAD: poly EL = -2.599872e-04 rad. Too low.

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:14.833 2009  to  Sat Jan  3 04:58:14.833 2009   (  0.00) secs
                    EL bad poly no. 436: BAD: poly EL = -3.894419e-04 rad. Too low.

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:17.898 2009  to  Sat Jan  3 04:58:17.898 2009   (  0.00) secs
                    EL bad poly no. 481: BAD: poly EL = -5.191714e-04 rad. Too low.

  71  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:20.896 2009  to  Sat Jan  3 04:58:20.896 2009   (  0.00) secs
                    EL bad poly no. 526: BAD: poly EL = -6.460765e-04 rad. Too low.

  72  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:23.915 2009  to  Sat Jan  3 04:58:23.915 2009   (  0.00) secs
                    EL bad poly no. 570: BAD: poly EL = -7.738417e-04 rad. Too low.

  73  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:26.965 2009  to  Sat Jan  3 04:58:26.965 2009   (  0.00) secs
                    EL bad poly no. 616: BAD: poly EL = -9.029348e-04 rad. Too low.

  74  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:29.990 2009  to  Sat Jan  3 04:58:29.990 2009   (  0.00) secs
                    EL bad poly no. 663: BAD: poly EL = -1.030895e-03 rad. Too low.

  75  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:33.005 2009  to  Sat Jan  3 04:58:33.005 2009   (  0.00) secs
                    EL bad poly no. 710: BAD: poly EL = -1.158459e-03 rad. Too low.

  76  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:36.038 2009  to  Sat Jan  3 04:58:36.038 2009   (  0.00) secs
                    EL bad poly no. 758: BAD: poly EL = -1.286779e-03 rad. Too low.

  77  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:39.066 2009  to  Sat Jan  3 04:58:39.066 2009   (  0.00) secs
                    EL bad poly no. 808: BAD: poly EL = -1.414865e-03 rad. Too low.

  78  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:42.117 2009  to  Sat Jan  3 04:58:42.117 2009   (  0.00) secs
                    EL bad poly no. 857: BAD: poly EL = -1.543976e-03 rad. Too low.

  79  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:45.153 2009  to  Sat Jan  3 04:58:45.153 2009   (  0.00) secs
                    EL bad poly no. 906: BAD: poly EL = -1.672351e-03 rad. Too low.

  80  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:48.158 2009  to  Sat Jan  3 04:58:48.158 2009   (  0.00) secs
                    EL bad poly no. 950: BAD: poly EL = -1.799441e-03 rad. Too low.

  81  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:51.219 2009  to  Sat Jan  3 04:58:51.219 2009   (  0.00) secs
                    EL bad poly no. 996: BAD: poly EL = -1.928836e-03 rad. Too low.

  82  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:54.282 2009  to  Sat Jan  3 04:58:54.282 2009   (  0.00) secs
                    EL bad poly no. 1042: BAD: poly EL = -2.058295e-03 rad. Too low.

  83  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 06:09:44.916 2009  to  Sat Jan  3 06:09:44.916 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  84  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.Stowpins.CommandStop                            Sat Jan  3 06:20:13.209 2009  to  Sat Jan  3 06:20:13.209 2009   (  0.00) secs
                    
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     side[0].tertiary_mirror. . . . . . . . . . . . . . . . . . . .      12                      
     side[0].secondary_mirror . . . . . . . . . . . . . . . . . . .      24                      

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                  
      Nothing to report

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     guider.command.adjustGSCoordinates . . . . . . . . . . . . . .    0.04    0.02    0.01    0.13   100.0 %          9          9                      
                                                                       0.04    0.02    0.01    0.13
     guider.command.applyGuideCorrection. . . . . . . . . . . . . .    0.02    0.02    0.01    0.11   100.0 %         64         64                      
                                                                       0.02    0.02    0.01    0.11
     guider.command.updateGuideOrigin . . . . . . . . . . . . . . .    2.34    1.66    0.00    3.31     0.0 %          2                     2             largeUpdate =     2
                                                                       0.00    3.31    3.31    3.31
     telescope.command.listPMTerms. . . . . . . . . . . . . . . . .    0.00    0.01    0.01    0.01   100.0 %          1          1                      
                                                                       0.00    0.01    0.01    0.01
     telescope.command.setNewInstrument . . . . . . . . . . . . . .    0.00    0.22    0.22    0.22   100.0 %          1          1                      
                                                                       0.00    0.22    0.22    0.22
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.00    0.01    0.01    0.02   100.0 %         10         10                      
                                                                       0.00    0.01    0.01    0.02
     telescope.command.setPMTerm. . . . . . . . . . . . . . . . . .    0.01    0.01    0.01    0.03   100.0 %          6          6                      
                                                                       0.01    0.01    0.01    0.03
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.36    0.52    0.00    0.78   100.0 %         10         10                      
                                                                       0.10    0.74    0.52    0.78
     telescope.command.stopTracking . . . . . . . . . . . . . . . .    0.01    0.03    0.03    0.04     0.0 %          2                     2           
                                                                                                   

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       1                      
     guider.telemetryError. . . . . . . . . . . . . . . . . . . . .                  1           

PCS Events of Interest

   1  FAILED    PCS        telescope.command.stopTracking                                Fri Jan  2 18:18:42.978 2009  to  Fri Jan  2 18:18:43.015 2009   (  0.04) secs
                    PCS will stop tracking target
                    PCS stop tracking command failed because ERROR: MCSPU is not connected.

   2  FAILED    PCS        telescope.command.stopTracking                                Fri Jan  2 18:18:43.844 2009  to  Fri Jan  2 18:18:43.873 2009   (  0.03) secs
                    PCS will stop tracking target
                    PCS stop tracking command failed because ERROR: MCSPU is not connected.

   3  FAILED    PCS        guider.telemetryError                                         Fri Jan  2 19:52:04.994 2009  to  Fri Jan  2 19:52:04.994 2009   (  0.00) secs
                    PCS Guider telemetry error: 2006: MySQL server has gone away

   4  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:53:42.638 2009  to  Fri Jan  2 19:56:56.118 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   5  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:53:42.907 2009  to  Fri Jan  2 19:53:42.907 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   6  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:56:56.118 2009  to  Fri Jan  2 20:04:46.585 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   7  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:56:56.388 2009  to  Fri Jan  2 19:56:56.388 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   8  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:13:55.386 2009  to  Fri Jan  2 20:13:55.395 2009   (  0.01) secs
                    

   9  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:15:24.690 2009  to  Fri Jan  2 20:15:24.698 2009   (  0.01) secs
                    

  10  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:36.340 2009  to  Fri Jan  2 20:16:36.349 2009   (  0.01) secs
                    

  11  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:51.057 2009  to  Fri Jan  2 20:16:51.065 2009   (  0.01) secs
                    

  12  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:57.801 2009  to  Fri Jan  2 20:16:57.812 2009   (  0.01) secs
                    

  13  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 20:18:11.474 2009  to  Fri Jan  2 22:22:54.599 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 20:18:11.745 2009  to  Fri Jan  2 20:18:11.745 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        guider.command.updateGuideOrigin                              Fri Jan  2 22:31:12.072 2009  to  Fri Jan  2 22:31:12.072 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.2500000e+00.
**********************************************************
PMC Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       2

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.activate.all. . . . . . . . . . . . . . . . .    0.01    1.04    1.03    1.05   100.0 %          3          3                      
                                                                       0.01    1.04    1.03    1.05
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    0.00    2.03    2.02    2.03   100.0 %          4          4                      
                                                                       0.00    2.03    2.02    2.03
     actuator.command.force.discardSoftAdjustments. . . . . . . . .    0.00    3.04    3.04    3.04   100.0 %          1          1                      
                                                                       0.00    3.04    3.04    3.04
     command.setElevationInMemory . . . . . . . . . . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     command.turnAllAirLoops. . . . . . . . . . . . . . . . . . . .    0.00    0.04    0.04    0.04     0.0 %          1                     1           
                                                                                                   
     hardPoint.command.setNewLvdtPositions. . . . . . . . . . . . .   35.40   54.15   29.11   79.18   100.0 %          2          2                      
                                                                      35.40   54.15   29.11   79.18
     mirror.command.chase.single. . . . . . . . . . . . . . . . . .    0.00  139.31  139.31  139.31   100.0 %          1          1                      
                                                                       0.00  139.31  139.31  139.31
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.01    2.04    2.04    2.05   100.0 %          2          2                      
                                                                       0.01    2.04    2.04    2.05
     mirror.command.goToPosition.absolute . . . . . . . . . . . . .   22.93   18.51    2.03   77.19    87.5 %         16         14          2           
                                                                      24.28   19.79    2.03   77.19
     mirror.command.raise.auto. . . . . . . . . . . . . . . . . . .    0.00  210.57  210.57  210.57   100.0 %          1          1                      
                                                                       0.00  210.57  210.57  210.57
     mirror.command.setElevation. . . . . . . . . . . . . . . . . .    0.00    0.08    0.08    0.08   100.0 %          1          1                      
                                                                       0.00    0.08    0.08    0.08

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      21                      
     actuator.telemetryError. . . . . . . . . . . . . . . . . . . .                  2           
     airPressure.telemetryInfo. . . . . . . . . . . . . . . . . . .       2                      
     motor.telemetryInfo. . . . . . . . . . . . . . . . . . . . . .       2                      
     hardPoint.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     mirror.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      
     servoLoop.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     thermal.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     cellStatus.telemetryInfo . . . . . . . . . . . . . . . . . . .       2                      
     thermal.staleThermalData . . . . . . . . . . . . . . . . . . .                            12
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     servoLoop.lowerLimit.exceeded. . . . . . . . . . . . . . . . .                             1
     servoLoop.iLowerLimit.exceeded . . . . . . . . . . . . . . . .                             1
     actuator.power.off . . . . . . . . . . . . . . . . . . . . . .                            12
     actuator.disabled. . . . . . . . . . . . . . . . . . . . . . .                             4
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       2                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                 11           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                 11           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                 11           
     mirror.raise . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.up. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.close. . . . . . . . . . . . . . . . . . . . . . . .       4                      
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            10
     mirror.magic . . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     outerLoop.open . . . . . . . . . . . . . . . . . . . . . . . .       3                      
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                             2
     VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                  1           
     VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                  1           
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .       4                      

PMC Events of Interest

   1  FAILED    PMC        actuator.telemetryError                                       Fri Jan  2 18:17:55.917 2009  to  Fri Jan  2 18:17:55.917 2009   (  0.00) secs
                    left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   2  STARTUP   PMC        startup                                                       Fri Jan  2 18:17:58.465 2009  to  Fri Jan  2 18:17:58.465 2009   (  0.00) secs
                    left PMC subsystem started, version 4.4

   3  FAILED    PMC        actuator.telemetryError                                       Fri Jan  2 18:19:39.942 2009  to  Fri Jan  2 18:19:39.942 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

   4  STARTUP   PMC        startup                                                       Fri Jan  2 18:19:43.082 2009  to  Fri Jan  2 18:19:43.082 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

   5  FAILED    PMC        command.turnAllAirLoops                                       Fri Jan  2 18:23:22.168 2009  to  Fri Jan  2 18:23:22.204 2009   (  0.04) secs
                    left PMC TurnAllAirLoops Command Started for ONOFF Flag: 0
                    left PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because Wrong air state

   6  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 18:24:32.557 2009  to  Fri Jan  2 18:24:32.557 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

   7  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 18:24:32.531 2009  to  Fri Jan  2 18:24:32.531 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

   8  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 18:24:32.512 2009  to  Fri Jan  2 18:24:32.512 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

   9  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan  2 18:31:25.491 2009  to  Fri Jan  2 18:31:30.573 2009   (  5.08) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  10  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 18:45:06.190 2009  to  Fri Jan  2 18:45:06.190 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  11  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 18:45:06.164 2009  to  Fri Jan  2 18:45:06.164 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  12  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 18:45:06.210 2009  to  Fri Jan  2 18:45:06.210 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  13  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 19:19:55.868 2009  to  Fri Jan  2 19:19:55.868 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  14  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 19:19:55.931 2009  to  Fri Jan  2 19:19:55.931 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  15  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 19:19:55.902 2009  to  Fri Jan  2 19:19:55.902 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan  2 20:11:44.079 2009  to  Fri Jan  2 20:11:58.157 2009   ( 14.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  17  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 20:18:32.614 2009  to  Fri Jan  2 20:18:32.614 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  18  FAILED    PMC        VxInterface.close                                             Fri Jan  2 20:18:32.638 2009  to  Fri Jan  2 20:18:32.638 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  19  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:04:56.742 2009  to  Fri Jan  2 21:04:56.742 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  20  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:04:56.715 2009  to  Fri Jan  2 21:04:56.715 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  21  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:04:56.770 2009  to  Fri Jan  2 21:04:56.770 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  22  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:18:23.908 2009  to  Fri Jan  2 21:18:23.908 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  23  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:18:23.883 2009  to  Fri Jan  2 21:18:23.883 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  24  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:18:23.930 2009  to  Fri Jan  2 21:18:23.930 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  25  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:42:41.391 2009  to  Fri Jan  2 21:42:41.391 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  26  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:42:41.445 2009  to  Fri Jan  2 21:42:41.445 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  27  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:42:41.421 2009  to  Fri Jan  2 21:42:41.421 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  28  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 22:08:28.371 2009  to  Fri Jan  2 22:08:28.371 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  29  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 22:08:28.426 2009  to  Fri Jan  2 22:08:28.426 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  30  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 22:08:28.399 2009  to  Fri Jan  2 22:08:28.399 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  31  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 22:45:26.448 2009  to  Fri Jan  2 22:45:26.448 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  32  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 22:45:26.419 2009  to  Fri Jan  2 22:45:26.419 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  33  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 22:45:26.472 2009  to  Fri Jan  2 22:45:26.472 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  34  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 01:59:59.166 2009  to  Sat Jan  3 01:59:59.166 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  35  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 01:59:59.237 2009  to  Sat Jan  3 01:59:59.237 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  36  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 01:59:59.211 2009  to  Sat Jan  3 01:59:59.211 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  37  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 06:05:49.545 2009  to  Sat Jan  3 06:05:49.545 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  38  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 06:05:49.605 2009  to  Sat Jan  3 06:05:49.605 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  39  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 06:05:49.570 2009  to  Sat Jan  3 06:05:49.570 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  40  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 06:13:43.885 2009  to  Sat Jan  3 06:13:43.885 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  41  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 06:13:43.861 2009  to  Sat Jan  3 06:13:43.861 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  42  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 06:13:43.916 2009  to  Sat Jan  3 06:13:43.916 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    2.57   14.33   11.66   18.57   100.0 %          6          6                      
                                                                       2.57   14.33   11.66   18.57
     command.setNewInstrument . . . . . . . . . . . . . . . . . . .    0.23    0.21    0.05    0.37   100.0 %          2          2                      
                                                                       0.23    0.21    0.05    0.37
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    2.57   14.38   11.70   18.61   100.0 %          6          6                      
                                                                       2.57   14.38   11.70   18.61
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    3.03    4.12    0.22    6.58   100.0 %          6          6                      
                                                                       3.03    4.12    0.22    6.58
     primaryMirror.command.adjustMirrorCollimation. . . . . . . . .   22.93   18.60    2.09   77.27    87.5 %         16         14          2           
                                                                      24.28   19.88    2.09   77.27
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.04    2.16    2.13    2.18   100.0 %          2          2                      
                                                                       0.04    2.16    2.13    2.18
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .    0.00    3.15    3.15    3.15   100.0 %          1          1                      
                                                                       0.00    3.15    3.15    3.15
     primaryMirror.command.clearPositions . . . . . . . . . . . . .    0.00   14.20   14.20   14.20     0.0 %          1                     1           
                                                                                                   
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.03    0.07    0.04    0.16   100.0 %         20         20                      
                                                                       0.03    0.07    0.04    0.16
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.13    0.13    0.13   100.0 %          1          1                      
                                                                       0.00    0.13    0.13    0.13
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .    0.00   33.39   33.39   33.39   100.0 %          1          1                      
                                                                       0.00   33.39   33.39   33.39
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    0.00   11.24   11.24   11.24   100.0 %          1          1                      
                                                                       0.00   11.24   11.24   11.24
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.00    0.02    0.02    0.02   100.0 %          6          6                      
                                                                       0.00    0.02    0.02    0.02
     secondaryMirror.command.adjustMirror . . . . . . . . . . . . .    4.30   10.04    5.93   18.13   100.0 %          6          6                      
                                                                       4.30   10.04    5.93   18.13
     secondaryMirror.command.adjustMirrorCollimation. . . . . . . .    4.78    6.35    2.31   18.05   100.0 %         12         12                      
                                                                       4.78    6.35    2.31   18.05
     secondaryMirror.command.initMirrorCollimation. . . . . . . . .    0.00    0.05    0.05    0.05   100.0 %          1          1                      
                                                                       0.00    0.05    0.05    0.05
     secondaryMirror.command.setZernikes. . . . . . . . . . . . . .    0.01    0.03    0.02    0.05   100.0 %          6          6                      
                                                                       0.01    0.03    0.02    0.05
     tertiaryMirror.command.adjustMirrorCollimation . . . . . . . .    0.03    0.12    0.10    0.16   100.0 %          5          5                      
                                                                       0.03    0.12    0.10    0.16
     tertiaryMirror.command.initMirrorCollimation . . . . . . . . .    0.00    0.07    0.07    0.07   100.0 %          1          1                      
                                                                       0.00    0.07    0.07    0.07

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan  2 18:31:25.444 2009  to  Fri Jan  2 18:31:30.606 2009   (  5.16) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

   2  FAILED    PSF        primaryMirror.command.clearPositions                          Fri Jan  2 20:11:44.022 2009  to  Fri Jan  2 20:11:58.223 2009   ( 14.20) secs
                    left PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

   3  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan  2 20:11:44.051 2009  to  Fri Jan  2 20:11:58.198 2009   ( 14.15) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 16:59:52.728 2009  to  Fri Jan  2 16:59:52.728 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 16:59:52.736 2009  to  Fri Jan  2 16:59:52.736 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

   3  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 16:59:52.833 2009  to  Fri Jan  2 16:59:52.833 2009   (  0.00) secs
                    drive cabinet has turned on.

   4  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.337 2009  to  Fri Jan  2 16:59:53.337 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   5  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.337 2009  to  Fri Jan  2 16:59:53.337 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   6  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.338 2009  to  Fri Jan  2 16:59:53.338 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   7  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.339 2009  to  Fri Jan  2 16:59:53.339 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   8  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.341 2009  to  Fri Jan  2 16:59:53.341 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

   9  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.341 2009  to  Fri Jan  2 16:59:53.341 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  10  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.342 2009  to  Fri Jan  2 16:59:53.342 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  11  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 16:59:53.343 2009  to  Fri Jan  2 16:59:53.343 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:04:40.171 2009  to  Fri Jan  2 17:04:40.171 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:04:40.180 2009  to  Fri Jan  2 17:04:40.180 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  14  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:04:40.270 2009  to  Fri Jan  2 17:04:40.270 2009   (  0.00) secs
                    drive cabinet has turned on.

  15  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.776 2009  to  Fri Jan  2 17:04:40.776 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  16  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.776 2009  to  Fri Jan  2 17:04:40.776 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  17  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.777 2009  to  Fri Jan  2 17:04:40.777 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  18  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.778 2009  to  Fri Jan  2 17:04:40.778 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  19  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.779 2009  to  Fri Jan  2 17:04:40.779 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  20  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.780 2009  to  Fri Jan  2 17:04:40.780 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  21  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.780 2009  to  Fri Jan  2 17:04:40.780 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  22  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:04:40.781 2009  to  Fri Jan  2 17:04:40.781 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:21:05.514 2009  to  Fri Jan  2 17:21:05.514 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:21:05.520 2009  to  Fri Jan  2 17:21:05.520 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  25  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:21:05.614 2009  to  Fri Jan  2 17:21:05.614 2009   (  0.00) secs
                    drive cabinet has turned on.

  26  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.122 2009  to  Fri Jan  2 17:21:06.122 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  27  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.122 2009  to  Fri Jan  2 17:21:06.122 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  28  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.123 2009  to  Fri Jan  2 17:21:06.123 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  29  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.124 2009  to  Fri Jan  2 17:21:06.124 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  30  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.125 2009  to  Fri Jan  2 17:21:06.125 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  31  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.126 2009  to  Fri Jan  2 17:21:06.126 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  32  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.126 2009  to  Fri Jan  2 17:21:06.126 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  33  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:21:06.128 2009  to  Fri Jan  2 17:21:06.128 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  34  FAILED    MCS.MCSPU  MCSPU.ELDrive.stowpinCommandRejected                          Fri Jan  2 17:25:19.077 2009  to  Fri Jan  2 17:25:19.077 2009   (  0.00) secs
                    A left stowpin command was not queued because queue was full or arguments were bad.

  35  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.Stowpins.CommandStop                            Fri Jan  2 17:32:56.186 2009  to  Fri Jan  2 17:32:56.186 2009   (  0.00) secs
                    

  36  FAILED    MCS.MCSPU  MCSPU.SwingArm.lockoutNotZenith                               Fri Jan  2 17:49:59.991 2009  to  Fri Jan  2 17:49:59.991 2009   (  0.00) secs
                    swingarms locked out because telescope is not stowed at zenith.

  37  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.commandReceived                                 Fri Jan  2 17:50:10.679 2009  to  Fri Jan  2 17:50:10.679 2009   (  0.00) secs
                    

  38  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:53:08.796 2009  to  Fri Jan  2 17:53:08.796 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  39  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:53:08.804 2009  to  Fri Jan  2 17:53:08.804 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  40  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 17:53:08.898 2009  to  Fri Jan  2 17:53:08.898 2009   (  0.00) secs
                    drive cabinet has turned on.

  41  FAILED    MCS.MCSPU  MCSPU.AZDrive.nullState                                       Fri Jan  2 17:56:45.215 2009  to  Fri Jan  2 17:56:45.215 2009   (  0.00) secs
                    Drive state machiine has state variable = 0, which is illegal. Shutting down axis.

  42  FAILED    MCS.MCSPU  MCSPU.ELDrive.commandIgnored                                  Fri Jan  2 17:56:45.216 2009  to  Fri Jan  2 17:56:45.216 2009   (  0.00) secs
                    Axis drive command was ignored because the drive cabinet is turned off.

  43  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:59:07.357 2009  to  Fri Jan  2 17:59:07.357 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  44  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 17:59:07.362 2009  to  Fri Jan  2 17:59:07.362 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  45  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 18:02:54.588 2009  to  Fri Jan  2 18:02:54.588 2009   (  0.00) secs
                    drive cabinet has turned on.

  46  FAILED    PMC        actuator.telemetryError                                       Fri Jan  2 18:17:55.917 2009  to  Fri Jan  2 18:17:55.917 2009   (  0.00) secs
                    left PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  47  STARTUP   PMC        startup                                                       Fri Jan  2 18:17:58.465 2009  to  Fri Jan  2 18:17:58.465 2009   (  0.00) secs
                    left PMC subsystem started, version 4.4

  48  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Jan  2 18:18:42.563 2009  to  Fri Jan  2 18:18:46.668 2009   (  4.10) secs
                    IIF TCS authorize command started for right LBC at prime focus
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF primary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF secondary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF tertiary mirror initMirrorCollimation complete
                    IIF TCS authorize failure for left LUCIFER at bentGregorianFront focus: left PSF SetNewInstrument complete for instrument LUCIFER, focal station bentGregorianFront
                    IIF TCS authorize command failed for left LUCIFER at bentGregorianFront focus

  49  FAILED    IIF GUI    IIFCommand.authorize                                          Fri Jan  2 18:18:42.666 2009  to  Fri Jan  2 18:18:46.934 2009   (  4.27) secs
                    IIF TCS authorize failure for right LBC at prime focus: PCS stop tracking command failed because ERROR: MCSPU is not connected.
                    IIF TCS authorize failure for right LBC at prime focus: right PSF SetNewInstrument complete for instrument LBC, focal station prime
                    IIF TCS authorize command failed for right LBC at prime focus

  50  FAILED    PCS        telescope.command.stopTracking                                Fri Jan  2 18:18:42.978 2009  to  Fri Jan  2 18:18:43.015 2009   (  0.04) secs
                    PCS will stop tracking target
                    PCS stop tracking command failed because ERROR: MCSPU is not connected.

  51  FAILED    PCS        telescope.command.stopTracking                                Fri Jan  2 18:18:43.844 2009  to  Fri Jan  2 18:18:43.873 2009   (  0.03) secs
                    PCS will stop tracking target
                    PCS stop tracking command failed because ERROR: MCSPU is not connected.

  52  FAILED    PMC        actuator.telemetryError                                       Fri Jan  2 18:19:39.942 2009  to  Fri Jan  2 18:19:39.942 2009   (  0.00) secs
                    right PMC Actuator telemetry error: The number of measures per telemeter may not exceed 999.

  53  STARTUP   PMC        startup                                                       Fri Jan  2 18:19:43.082 2009  to  Fri Jan  2 18:19:43.082 2009   (  0.00) secs
                    right PMC subsystem started, version 4.4

  54  FAILED    PMC        command.turnAllAirLoops                                       Fri Jan  2 18:23:22.168 2009  to  Fri Jan  2 18:23:22.204 2009   (  0.04) secs
                    left PMC TurnAllAirLoops Command Started for ONOFF Flag: 0
                    left PMC TurnAllAirLoops Command Failed for ONOFF Flag: ON because Wrong air state

  55  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 18:24:17.069 2009  to  Fri Jan  2 18:24:17.069 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  56  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 18:24:17.074 2009  to  Fri Jan  2 18:24:17.074 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  57  FAILED    MCS.MCSPU  MCSPU.Cabinet.cabinetOn                                       Fri Jan  2 18:24:17.169 2009  to  Fri Jan  2 18:24:17.169 2009   (  0.00) secs
                    drive cabinet has turned on.

  58  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 18:24:32.557 2009  to  Fri Jan  2 18:24:32.557 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  59  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 18:24:32.531 2009  to  Fri Jan  2 18:24:32.531 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  60  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 18:24:32.512 2009  to  Fri Jan  2 18:24:32.512 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan  2 18:31:25.491 2009  to  Fri Jan  2 18:31:30.573 2009   (  5.08) secs
                    right PMC Mirror ChaseStop Command Started
                    right PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  62  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan  2 18:31:25.444 2009  to  Fri Jan  2 18:31:30.606 2009   (  5.16) secs
                    right PSF primary mirror chaseStop started
                    right PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  63  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 18:45:06.190 2009  to  Fri Jan  2 18:45:06.190 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  64  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 18:45:06.164 2009  to  Fri Jan  2 18:45:06.164 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  65  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 18:45:06.210 2009  to  Fri Jan  2 18:45:06.210 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  66  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 19:19:55.868 2009  to  Fri Jan  2 19:19:55.868 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  67  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 19:19:55.931 2009  to  Fri Jan  2 19:19:55.931 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  68  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 19:19:55.902 2009  to  Fri Jan  2 19:19:55.902 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  69  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 19:43:01.729 2009  to  Fri Jan  2 19:43:01.729 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

  70  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 19:43:01.734 2009  to  Fri Jan  2 19:43:01.734 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  71  FAILED    MCS.MCSPU  MCSPU.RTracker.polyStop                                       Fri Jan  2 19:43:02.680 2009  to  Fri Jan  2 19:43:02.680 2009   (  0.00) secs
                    There have been no LFBG track polys for 2.000000000000000e+00 .

  72  FAILED    MCS.MCSPU  MCSPU.ELDrive.ampsOnAckFail                                   Fri Jan  2 19:43:22.662 2009  to  Fri Jan  2 19:43:22.662 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  73  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:49:28.893 2009  to  Fri Jan  2 19:52:30.391 2009   (181.50) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.443063, 0.279351, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

  74  FAILED    PCS        guider.telemetryError                                         Fri Jan  2 19:52:04.994 2009  to  Fri Jan  2 19:52:04.994 2009   (  0.00) secs
                    PCS Guider telemetry error: 2006: MySQL server has gone away

  75  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 19:52:30.307 2009  to  Fri Jan  2 19:52:30.307 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 4.430627852829885e-01,2.793512292485157e-01, focus: 3.158714015370968e+01 mm. AGw returned: AGW1: RPC Communication Error

  76  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:53:42.427 2009  to  Fri Jan  2 19:55:56.149 2009   (133.72) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: Invalid buffer: RPCERROR
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

  77  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:53:42.638 2009  to  Fri Jan  2 19:56:56.118 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  78  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:53:42.907 2009  to  Fri Jan  2 19:53:42.907 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  79  SHUTDOWN  GCS        command.shutdown                                              Fri Jan  2 19:54:54.227 2009  to  Fri Jan  2 19:54:54.227 2009   (  0.00) secs
                    left GCS ShutDown Command Started

  80  SHUTDOWN  GCS        command.shutdown                                              Fri Jan  2 19:55:46.580 2009  to  Fri Jan  2 19:55:46.580 2009   (  0.00) secs
                    left GCS ShutDown Command Complete

  81  STARTUP   GCS        startup                                                       Fri Jan  2 19:56:41.981 2009  to  Fri Jan  2 19:56:41.981 2009   (  0.00) secs
                    left GCS subsystem started

  82  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 19:56:55.987 2009  to  Fri Jan  2 20:00:19.630 2009   (203.64) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.236512, 0.471056, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

  83  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:56:56.118 2009  to  Fri Jan  2 20:04:46.585 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  84  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 19:56:56.388 2009  to  Fri Jan  2 19:56:56.388 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  85  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:00:19.556 2009  to  Fri Jan  2 20:00:19.556 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.365118312569743e-01,4.710558971946952e-01, focus: 3.158713509430014e+01 mm. AGw returned: AGW1: RPC Communication Error

  86  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 20:04:46.422 2009  to  Fri Jan  2 20:04:51.515 2009   (  5.09) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Error
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: RPC Communication Errorerror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.230155, 0.468411, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

  87  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:04:51.395 2009  to  Fri Jan  2 20:04:51.395 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.301548300535630e-01,4.684110618474666e-01, focus: 3.158714300699662e+01 mm. AGw returned: AGW1: RPC Communication Error

  88  FAILED    IIF        command.preset.(ACQUIRE)                                      Fri Jan  2 20:07:10.829 2009  to  Fri Jan  2 20:07:25.352 2009   ( 14.52) secs
                    IIF Preset command started for left LUCIFER mode ACQUIRE from IIF
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: Axes had not been homed, yet
                    IIF Preset failure for left LUCIFER mode ACQUIRE: AGw command status: AGW1: Axes had not been homed, yeterror: setProbePosition: couldn't move probe to position (SFP) (x,y,z): 0.226937, 0.46704, 31.5871 mm.
                    IIF Preset failure for left LUCIFER mode ACQUIRE: guidestar list successfully changed but probe couldn't be moved to position.
                    IIF Preset command failed for left LUCIFER mode ACQUIRE from IIF

  89  FAILED    GCS        interface.agw.setProbePosition                                Fri Jan  2 20:07:25.272 2009  to  Fri Jan  2 20:07:25.272 2009   (  0.00) secs
                    setProbePosition: couldn't move probe to position SFP 2.269368176978064e-01,4.670396767354393e-01, focus: 3.158714702425744e+01 mm. AGw returned: AGW1: Axes had not been homed, yet

  90  FAILED    PSF        primaryMirror.command.clearPositions                          Fri Jan  2 20:11:44.022 2009  to  Fri Jan  2 20:11:58.223 2009   ( 14.20) secs
                    left PSF primary mirror active optics positions failed to clear because Primary mirror collimation failed

  91  FAILED    PMC        mirror.command.goToPosition.absolute                          Fri Jan  2 20:11:44.079 2009  to  Fri Jan  2 20:11:58.157 2009   ( 14.08) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  92  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Fri Jan  2 20:11:44.051 2009  to  Fri Jan  2 20:11:58.198 2009   ( 14.15) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  93  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:13:55.386 2009  to  Fri Jan  2 20:13:55.395 2009   (  0.01) secs
                    

  94  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:15:24.690 2009  to  Fri Jan  2 20:15:24.698 2009   (  0.01) secs
                    

  95  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:36.340 2009  to  Fri Jan  2 20:16:36.349 2009   (  0.01) secs
                    

  96  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:51.057 2009  to  Fri Jan  2 20:16:51.065 2009   (  0.01) secs
                    

  97  SXDXBOTH  PCS        telescope.command.setPMTerm                                   Fri Jan  2 20:16:57.801 2009  to  Fri Jan  2 20:16:57.812 2009   (  0.01) secs
                    

  98  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 20:18:11.474 2009  to  Fri Jan  2 22:22:54.599 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  99  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 20:18:11.745 2009  to  Fri Jan  2 20:18:11.745 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 100  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 20:18:32.614 2009  to  Fri Jan  2 20:18:32.614 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 101  FAILED    PMC        VxInterface.close                                             Fri Jan  2 20:18:32.638 2009  to  Fri Jan  2 20:18:32.638 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 102  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:04:56.742 2009  to  Fri Jan  2 21:04:56.742 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 103  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:04:56.715 2009  to  Fri Jan  2 21:04:56.715 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 104  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:04:56.770 2009  to  Fri Jan  2 21:04:56.770 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 105  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:18:23.908 2009  to  Fri Jan  2 21:18:23.908 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 106  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:18:23.883 2009  to  Fri Jan  2 21:18:23.883 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 107  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:18:23.930 2009  to  Fri Jan  2 21:18:23.930 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 108  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 21:42:41.391 2009  to  Fri Jan  2 21:42:41.391 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 109  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 21:42:41.445 2009  to  Fri Jan  2 21:42:41.445 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 110  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 21:42:41.421 2009  to  Fri Jan  2 21:42:41.421 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 111  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 22:08:28.371 2009  to  Fri Jan  2 22:08:28.371 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 112  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 22:08:28.426 2009  to  Fri Jan  2 22:08:28.426 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 113  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 22:08:28.399 2009  to  Fri Jan  2 22:08:28.399 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 114  FAILED    IIF        command.preset.(ACTIVE)                                       Fri Jan  2 22:22:54.447 2009  to  Fri Jan  2 22:24:31.907 2009   ( 97.46) secs
                    IIF Preset command started for left LUCIFER mode ACTIVE from IIF
                    IIF Preset failure for left LUCIFER mode ACTIVE: left PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset failure for left LUCIFER mode ACTIVE: couldn't find a star in any GS location.
                    IIF Preset command failed for left LUCIFER mode ACTIVE from IIF

 115  FAILED    GCS        command.autoAcquireGuidestar.starDetection                    Fri Jan  2 22:24:18.279 2009  to  Fri Jan  2 22:24:31.809 2009   ( 13.53) secs
                    couldn't find a star in any GS location.

 116  SEQERROR  PCS        guider.command.updateGuideOrigin                              Fri Jan  2 22:31:12.072 2009  to  Fri Jan  2 22:31:12.072 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.2500000e+00.

 117  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 22:45:26.448 2009  to  Fri Jan  2 22:45:26.448 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 118  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 22:45:26.419 2009  to  Fri Jan  2 22:45:26.419 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 119  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 22:45:26.472 2009  to  Fri Jan  2 22:45:26.472 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 120  FAILED    MCS.MCSPU  MCSPU.AZDrive.bldgCantFollow                                  Sat Jan  3 00:56:28.575 2009  to  Sat Jan  3 00:56:28.575 2009   (  0.00) secs
                    MOTION_EN or Msg_Encl_Folw_Tel signal has gone false. Bldg can't follow tel. Going to "hold" mode.

 121  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 01:59:59.166 2009  to  Sat Jan  3 01:59:59.166 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 122  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 01:59:59.237 2009  to  Sat Jan  3 01:59:59.237 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 123  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 01:59:59.211 2009  to  Sat Jan  3 01:59:59.211 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 124  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:26.818 2009  to  Sat Jan  3 04:44:26.818 2009   (  0.00) secs
                    EL bad poly no. 1: BAD: poly EL = -2.198764e-03 rad. Too low.

 125  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:44:27.781 2009  to  Sat Jan  3 04:44:27.781 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 126  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:29.868 2009  to  Sat Jan  3 04:44:29.868 2009   (  0.00) secs
                    EL bad poly no. 58: BAD: poly EL = -2.995022e-02 rad. Too low.

 127  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:44:32.892 2009  to  Sat Jan  3 04:44:32.892 2009   (  0.00) secs
                    EL bad poly no. 104: BAD: poly EL = -2.005203e-01 rad. Too low.

 128  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:46:54.524 2009  to  Sat Jan  3 04:46:54.524 2009   (  0.00) secs
                    EL bad poly no. 107: BAD: poly EL = -1.382628e-03 rad. Too low.

 129  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:46:55.494 2009  to  Sat Jan  3 04:46:55.494 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 130  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:46:57.557 2009  to  Sat Jan  3 04:46:57.557 2009   (  0.00) secs
                    EL bad poly no. 162: BAD: poly EL = -1.438929e-02 rad. Too low.

 131  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:00.611 2009  to  Sat Jan  3 04:47:00.611 2009   (  0.00) secs
                    EL bad poly no. 208: BAD: poly EL = -5.194085e-02 rad. Too low.

 132  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:36.121 2009  to  Sat Jan  3 04:47:36.121 2009   (  0.00) secs
                    EL bad poly no. 211: BAD: poly EL = -7.703964e-03 rad. Too low.

 133  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:47:37.115 2009  to  Sat Jan  3 04:47:37.115 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 134  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:47:39.126 2009  to  Sat Jan  3 04:47:39.126 2009   (  0.00) secs
                    EL bad poly no. 269: BAD: poly EL = -4.627769e-02 rad. Too low.

 135  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:05.654 2009  to  Sat Jan  3 04:58:05.654 2009   (  0.00) secs
                    EL bad poly no. 288: BAD: poly EL = -7.398658e-07 rad. Too low.

 136  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 04:58:06.632 2009  to  Sat Jan  3 04:58:06.632 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 137  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:08.723 2009  to  Sat Jan  3 04:58:08.723 2009   (  0.00) secs
                    EL bad poly no. 345: BAD: poly EL = -1.307165e-04 rad. Too low.

 138  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:11.776 2009  to  Sat Jan  3 04:58:11.776 2009   (  0.00) secs
                    EL bad poly no. 391: BAD: poly EL = -2.599872e-04 rad. Too low.

 139  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:14.833 2009  to  Sat Jan  3 04:58:14.833 2009   (  0.00) secs
                    EL bad poly no. 436: BAD: poly EL = -3.894419e-04 rad. Too low.

 140  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:17.898 2009  to  Sat Jan  3 04:58:17.898 2009   (  0.00) secs
                    EL bad poly no. 481: BAD: poly EL = -5.191714e-04 rad. Too low.

 141  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:20.896 2009  to  Sat Jan  3 04:58:20.896 2009   (  0.00) secs
                    EL bad poly no. 526: BAD: poly EL = -6.460765e-04 rad. Too low.

 142  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:23.915 2009  to  Sat Jan  3 04:58:23.915 2009   (  0.00) secs
                    EL bad poly no. 570: BAD: poly EL = -7.738417e-04 rad. Too low.

 143  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:26.965 2009  to  Sat Jan  3 04:58:26.965 2009   (  0.00) secs
                    EL bad poly no. 616: BAD: poly EL = -9.029348e-04 rad. Too low.

 144  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:29.990 2009  to  Sat Jan  3 04:58:29.990 2009   (  0.00) secs
                    EL bad poly no. 663: BAD: poly EL = -1.030895e-03 rad. Too low.

 145  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:33.005 2009  to  Sat Jan  3 04:58:33.005 2009   (  0.00) secs
                    EL bad poly no. 710: BAD: poly EL = -1.158459e-03 rad. Too low.

 146  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:36.038 2009  to  Sat Jan  3 04:58:36.038 2009   (  0.00) secs
                    EL bad poly no. 758: BAD: poly EL = -1.286779e-03 rad. Too low.

 147  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:39.066 2009  to  Sat Jan  3 04:58:39.066 2009   (  0.00) secs
                    EL bad poly no. 808: BAD: poly EL = -1.414865e-03 rad. Too low.

 148  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:42.117 2009  to  Sat Jan  3 04:58:42.117 2009   (  0.00) secs
                    EL bad poly no. 857: BAD: poly EL = -1.543976e-03 rad. Too low.

 149  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:45.153 2009  to  Sat Jan  3 04:58:45.153 2009   (  0.00) secs
                    EL bad poly no. 906: BAD: poly EL = -1.672351e-03 rad. Too low.

 150  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:48.158 2009  to  Sat Jan  3 04:58:48.158 2009   (  0.00) secs
                    EL bad poly no. 950: BAD: poly EL = -1.799441e-03 rad. Too low.

 151  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:51.219 2009  to  Sat Jan  3 04:58:51.219 2009   (  0.00) secs
                    EL bad poly no. 996: BAD: poly EL = -1.928836e-03 rad. Too low.

 152  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Sat Jan  3 04:58:54.282 2009  to  Sat Jan  3 04:58:54.282 2009   (  0.00) secs
                    EL bad poly no. 1042: BAD: poly EL = -2.058295e-03 rad. Too low.

 153  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 06:05:49.545 2009  to  Sat Jan  3 06:05:49.545 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 154  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 06:05:49.605 2009  to  Sat Jan  3 06:05:49.605 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 155  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 06:05:49.570 2009  to  Sat Jan  3 06:05:49.570 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 156  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Sat Jan  3 06:09:44.916 2009  to  Sat Jan  3 06:09:44.916 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 157  FAILED    PMC        VxInterface.packetReadError                                   Sat Jan  3 06:13:43.885 2009  to  Sat Jan  3 06:13:43.885 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 158  FAILED    PMC        VxInterface.selectTimeout                                     Sat Jan  3 06:13:43.861 2009  to  Sat Jan  3 06:13:43.861 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 159  FAILED    PMC        thermal.badReceive                                            Sat Jan  3 06:13:43.916 2009  to  Sat Jan  3 06:13:43.916 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 160  SXDXBOTH  MCS.MCSPU  MCSPU.ELDrive.Stowpins.CommandStop                            Sat Jan  3 06:20:13.209 2009  to  Sat Jan  3 06:20:13.209 2009   (  0.00) secs
                    

**********************************************************
    Reporting period ending:   Sat Jan  3 07:52:59.964 2009
********************************************************************************************************